WorldWideScience

Sample records for sampling device archival

  1. Rapid surface sampling and archival record system (RSSAR)

    International Nuclear Information System (INIS)

    Barren, E.; Bracco, A.; Dorn, S.B.

    1997-01-01

    Purpose is to develop a rapid surface (concrete, steel) contamination measurement system that will provide a ''quick-look'' indication of contamination areas, an archival record, and an automated analysis. A bulk sampling oven is also being developed. The sampling device consists of a sampling head, a quick look detector, and an archiving system (sorbent tube). The head thermally desorbs semi-volatiles, such as PCBs, oils, etc., from concrete and steel surfaces; the volatilized materials are passed through a quick-look detector. Sensitivity of the detector can be attenuated for various contaminant levels. Volatilized materials are trapped in a tube filled with adsorbent. The tubes are housed in a magazine which also archives information about sampling conditions. Analysis of the tubes can be done at a later date. The concrete sampling head is fitted with a tungsten-halogen lamp; in laboratory experiments it has extracted model contaminants by heating the top 4mm of the surface to 250 C within 100-200 s. The steel sampling head has been tested on different types of steels and has extracted model contaminants within 30 s. A mathematical model of heat and mass transport in concrete has been developed. Rate of contaminant removal is at maximum when the moisture content is about 100 kg/m 3 . The system will be useful during decontamination and decommissioning operations

  2. Huge music archives on mobile devices

    DEFF Research Database (Denmark)

    Blume, H.; Bischl, B.; Botteck, M.

    2011-01-01

    The availability of huge nonvolatile storage capacities such as flash memory allows large music archives to be maintained even in mobile devices. With the increase in size, manual organization of these archives and manual search for specific music becomes very inconvenient. Automated dynamic...... organization enables an attractive new class of applications for managing ever-increasing music databases. For these types of applications, extraction of music features as well as subsequent feature processing and music classification have to be performed. However, these are computationally intensive tasks...... and difficult to tackle on mobile platforms. Against this background, we provided an overview of algorithms for music classification as well as their computation times and other hardware-related aspects, such as power consumption on various hardware architectures. For mobile platforms such as smartphones...

  3. Sample ontology, GOstat and ontology term enrichment - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM....biosciencedbc.jp/archive/fantom5/datafiles/LATEST/extra/Ontology/ File size: 1.8 MB Simple search URL - Dat...t Us Sample ontology, GOstat and ontology term enrichment - FANTOM5 | LSDB Archive ...

  4. Gamma spectroscopy analysis of archived Marshall Island soil samples

    International Nuclear Information System (INIS)

    Herman, S.; Hoffman, K.; Lavelle, K.; Trauth, A.; Glover, S.E.; Connick, W.; Spitz, H.; LaMont, S.P.; Hamilton, T.

    2016-01-01

    Four samples of archival Marshall Islands soil were subjected to non-destructive, broad energy (17 keV-2.61 MeV) gamma-ray spectrometry analysis using a series of different high-resolution germanium detectors. These archival samples were collected in 1967 from different locations on Bikini Atoll and were contaminated with a range of fission and activation products, and other nuclear material from multiple weapons tests. Unlike samples collected recently, these samples have been stored in sealed containers and have been unaffected by approximately 50 years of weathering. Initial results show that the samples contained measurable but proportionally different concentrations of plutonium, 241 Am, and 137 Cs, and 60 Co. (author)

  5. Chroni - an Android Application for Geochronologists to Access Archived Sample Analyses from the NSF-Funded Geochron.Org Data Repository.

    Science.gov (United States)

    Nettles, J. J.; Bowring, J. F.

    2014-12-01

    NSF requires data management plans as part of funding proposals and geochronologists, among other scientists, are archiving their data and results to the public cloud archives managed by the NSF-funded Integrated Earth Data Applications, or IEDA. GeoChron is a database for geochronology housed within IEDA. The software application U-Pb_Redux developed at the Cyber Infrastructure Research and Development Lab for the Earth Sciences (CIRDLES.org) at the College of Charleston provides seamless connectivity to GeoChron for uranium-lead (U-Pb) geochronologists to automatically upload and retrieve their data and results. U-Pb_Redux also manages publication-quality documents including report tables and graphs. CHRONI is a lightweight mobile application for Android devices that provides easy access to these archived data and results. With CHRONI, U-Pb geochronologists can view archived data and analyses downloaded from the Geochron database, or any other location, in a customizable format. CHRONI uses the same extensible markup language (XML) schema and documents used by U-Pb_Redux and GeoChron. Report Settings are special XML files that can be customized in U-Pb_Redux, stored in the cloud, and then accessed and used in CHRONI to create the same customized data display on the mobile device. In addition to providing geologists effortless and mobile access to archived data and analyses, CHRONI allows users to manage their GeoChron credentials, quickly download private and public files via a specified IEDA International Geo Sample Number (IGSN) or URL, and view specialized graphics associated with particular IGSNs. Future versions of CHRONI will be developed to support iOS compatible devices. CHRONI is an open source project under the Apache 2 license and is hosted at https://github.com/CIRDLES/CHRONI. We encourage community participation in its continued development.

  6. Hot sample archiving. Revision 3

    International Nuclear Information System (INIS)

    McVey, C.B.

    1995-01-01

    This Engineering Study revision evaluated the alternatives to provide tank waste characterization analytical samples for a time period as recommended by the Tank Waste Remediation Systems Program. The recommendation of storing 40 ml segment samples for a period of approximately 18 months (6 months past the approval date of the Tank Characterization Report) and then composite the core segment material in 125 ml containers for a period of five years. The study considers storage at 222-S facility. It was determined that the critical storage problem was in the hot cell area. The 40 ml sample container has enough material for approximately 3 times the required amount for a complete laboratory re-analysis. The final result is that 222-S can meet the sample archive storage requirements. During the 100% capture rate the capacity is exceeded in the hot cell area, but quick, inexpensive options are available to meet the requirements

  7. Stability of mercury concentration measurements in archived soil and peat samples

    Science.gov (United States)

    Navrátil, Tomáš; Burns, Douglas; Nováková, Tereza; Kaňa, Jiří; Rohovec, Jan; Roll, Michal; Ettler, Vojtěch

    2018-01-01

    Archived soil samples can provide important information on the history of environmental contamination and by comparison with recently collected samples, temporal trends can be inferred. Little previous work has addressed whether mercury (Hg) concentrations in soil samples are stable with long-term storage under standard laboratory conditions. In this study, we have re-analyzed using cold vapor atomic adsorption spectroscopy a set of archived soil samples that ranged from relatively pristine mountainous sites to a polluted site near a non-ferrous metal smelter with a wide range of Hg concentrations (6 - 6485 µg kg-1). Samples included organic and mineral soils and peats with a carbon content that ranged from 0.2 to 47.7%. Soil samples were stored in polyethylene bags or bottles and held in laboratory rooms where temperature was not kept to a constant value. Mercury concentrations in four subsets of samples were originally measured in 2000, 2005, 2006 and 2007, and re-analyzed in 2017, i.e. after 17, 12, 11 and 10 years of storage. Statistical analyses of either separated or lumped data yielded no significant differences between the original and current Hg concentrations. Based on these analyses, we show that archived soil and peat samples can be used to evaluate historical soil mercury contamination.

  8. Reactor water sampling device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo.

    1992-01-01

    The present invention concerns a reactor water sampling device for sampling reactor water in an in-core monitor (neutron measuring tube) housing in a BWR type reactor. The upper end portion of a drain pipe of the reactor water sampling device is attached detachably to an in-core monitor flange. A push-up rod is inserted in the drain pipe vertically movably. A sampling vessel and a vacuum pump are connected to the lower end of the drain pipe. A vacuum pump is operated to depressurize the inside of the device and move the push-up rod upwardly. Reactor water in the in-core monitor housing flows between the drain pipe and the push-up rod and flows into the sampling vessel. With such a constitution, reactor water in the in-core monitor housing can be sampled rapidly with neither opening the lid of the reactor pressure vessel nor being in contact with air. Accordingly, operator's exposure dose can be reduced. (I.N.)

  9. A Improved Seabed Surface Sand Sampling Device

    Science.gov (United States)

    Luo, X.

    2017-12-01

    In marine geology research it is necessary to obtain a suf fcient quantity of seabed surface samples, while also en- suring that the samples are in their original state. Currently,there are a number of seabed surface sampling devices available, but we fnd it is very diffcult to obtain sand samples using these devices, particularly when dealing with fne sand. Machine-controlled seabed surface sampling devices are also available, but generally unable to dive into deeper regions of water. To obtain larger quantities of seabed surface sand samples in their original states, many researchers have tried to improve upon sampling devices,but these efforts have generally produced ambiguous results, in our opinion.To resolve this issue, we have designed an improved andhighly effective seabed surface sand sampling device that incorporates the strengths of a variety of sampling devices. It is capable of diving into deepwater to obtain fne sand samples and is also suited for use in streams, rivers, lakes and seas with varying levels of depth (up to 100 m). This device can be used for geological mapping, underwater prospecting, geological engineering and ecological, environmental studies in both marine and terrestrial waters.

  10. [Quality of DNA from archival pathological samples of gallbladder cancer].

    Science.gov (United States)

    Roa, Iván; de Toro, Gonzalo; Sánchez, Tamara; Slater, Jeannie; Ziegler, Anne Marie; Game, Anakaren; Arellano, Leonardo; Schalper, Kurt; de Aretxabala, Xabier

    2013-12-01

    The quality of the archival samples stored at pathology services could be a limiting factor for molecular biology studies. To determine the quality of DNA extracted from gallbladder cancer samples at different institutions. One hundred ninety four samples coming from five medical centers in Chile, were analyzed. DNA extraction was quantified determining genomic DNA concentration. The integrity of DNA was determined by polymerase chain reaction amplification of different length fragments of a constitutive gene (β-globin products of 110, 268 and 501 base pairs). The mean DNA concentration obtained in 194 gallbladder cancer samples was 48 ± 43.1 ng/µl. In 22% of samples, no amplification was achieved despite obtaining a mean DNA concentration of 58.3 ng/ul. In 81, 67 and 22% of samples, a DNA amplification of at least 110, 268 or 501 base pairs was obtained, respectively. No differences in DNA concentration according to the source of the samples were demonstrated. However, there were marked differences in DNA integrity among participating centers. Samples from public hospitals were of lower quality than those from private clinics. Despite some limitations, in 80% of cases, the integrity of DNA in archival samples from pathology services in our country would allow the use of molecular biology techniques.

  11. PDS Archive Release of Apollo 11, Apollo 12, and Apollo 17 Lunar Rock Sample Images

    Science.gov (United States)

    Garcia, P. A.; Stefanov, W. L.; Lofgren, G. E.; Todd, N. S.; Gaddis, L. R.

    2013-01-01

    Scientists at the Johnson Space Center (JSC) Lunar Sample Laboratory, Information Resources Directorate, and Image Science & Analysis Laboratory have been working to digitize (scan) the original film negatives of Apollo Lunar Rock Sample photographs [1, 2]. The rock samples, and associated regolith and lunar core samples, were obtained during the Apollo 11, 12, 14, 15, 16 and 17 missions. The images allow scientists to view the individual rock samples in their original or subdivided state prior to requesting physical samples for their research. In cases where access to the actual physical samples is not practical, the images provide an alternate mechanism for study of the subject samples. As the negatives are being scanned, they have been formatted and documented for permanent archive in the NASA Planetary Data System (PDS). The Astromaterials Research and Exploration Science Directorate (which includes the Lunar Sample Laboratory and Image Science & Analysis Laboratory) at JSC is working collaboratively with the Imaging Node of the PDS on the archiving of these valuable data. The PDS Imaging Node is now pleased to announce the release of the image archives for Apollo missions 11, 12, and 17.

  12. Sampling device for radioactive molten salt

    International Nuclear Information System (INIS)

    Shindo, Masato

    1998-01-01

    The present invention provides a device for accurately sampling molten salts to which various kinds of metals in a molten salt storage tank are mixed for analyzing them during a spent fuel dry type reprocessing. Namely, the device comprises a sampling tube having an opened lower end to be inserted into the radioactive molten salts stored in a tank and keeps reduced pressure from the upper end, and a pressure reducing pipeline having one end connected to the sampling tube and other end connected to an evacuating pump. In this device, the top end of the sampling tube is inserted to a position for sampling the radioactive molten salts (molten salts). The pressure inside the evacuating pipeline connected to the upper portion of the sampling tube is reduced for a while. In this case, the inside of the pressure reducing pipeline is previously evacuated by the evacuating pump so as to keep a predetermined pressure. Since the pressure in the sampling tube is lowered, molten salts are inserted into the sampling tube, the sampling tube is withdrawn, and the molten salts flown in the sampling tube are analyzed. (I.S.)

  13. Archival policies and collections database for the Woods Hole Science Center's marine sediment samples

    Science.gov (United States)

    Buczkowski, Brian J.; Kelsey, Sarah A.

    2007-01-01

    The Woods Hole Science Center of the U.S. Geological Survey (USGS) has been an active member of the Woods Hole research community, Woods Hole, Massachusetts, for over 40 years. In that time there have been many projects that involved the collection of sediment samples conducted by USGS scientists and technicians for the research and study of seabed environments and processes. These samples were collected at sea or near shore and then brought back to the Woods Hole Science Center (WHSC) for analysis. While at the center, samples are stored in ambient temperature, refrigerated and freezing conditions ranging from +2º Celsius to -18º Celsius, depending on the best mode of preparation for the study being conducted or the duration of storage planned for the samples. Recently, storage methods and available storage space have become a major concern at the WHSC. The core and sediment archive program described herein has been initiated to set standards for the management, methods, and duration of sample storage. A need has arisen to maintain organizational consistency and define storage protocol. This handbook serves as a reference and guide to all parties interested in using and accessing the WHSC's sample archive and also defines all the steps necessary to construct and maintain an organized collection of geological samples. It answers many questions as to the way in which the archive functions.

  14. Experimental study of glass sampling devices

    International Nuclear Information System (INIS)

    Jouan, A.; Moncouyoux, J.P.; Meyere, A.

    1992-01-01

    Two high-level liquid waste containment glass sampling systems have been designed and built. The first device fits entirely inside a standard glass storage canister, and may thus be used in facilities not initially designed for this function. It has been tested successfully in the nonradioactive prototype unit at Marcoule. The work primarily covered the design and construction of an articulated arm supporting the sampling vessel, and the mechanisms necessary for filling the vessel and recovering the sample. System actuation and operation are fully automatic, and the resulting sample is representative of the glass melt. Implementation of the device is delicate however, and its reliability is estimated at about 75%. A second device was designed specifically for new vitrification facilities. It is installed directly on the glass melting furnace, and meets process operating and quality control requirements. Tests conducted at the Marcoule prototype vitrification facility demonstrated the feasibility of the system. Special attention was given to the sampling vessel transfer mechanisms, with two filling and controlled sample cooling options

  15. Device for sampling liquid radioactive materials

    International Nuclear Information System (INIS)

    Vlasak, L.

    1987-01-01

    Remote sampling of radioactive materials in the process of radioactive waste treatment is claimed by the Czechoslovak Patent Document 238599. The existing difficulties are eliminated consisting in a complex remote control of sampling featuring the control of sliding and rotary movements of the sampling device. The new device consists of a vertical pipe with an opening provided with a cover. A bend is provided above the opening level housing flow distributors. A sampling tray is pivoted in the cover. In sampling, the tray is tilted in the vertical pipe space while it tilts back when filled. The sample flows into a vessel below the tray. Only rotary movement is thus sufficient for controlling the tray. (Z.M.)

  16. Evaluating Quality of Aged Archival Formalin-Fixed Paraffin-Embedded Samples for RNA-Sequencing

    Science.gov (United States)

    Archival formalin-fixed paraffin-embedded (FFPE) samples offer a vast, untapped source of genomic data for biomarker discovery. However, the quality of FFPE samples is often highly variable, and conventional methods to assess RNA quality for RNA-sequencing (RNA-seq) are not infor...

  17. A novel fluorescent in situ hybridization technique for detection of Rickettsia spp. in archival samples

    DEFF Research Database (Denmark)

    Svendsen, Claus Bo; Boye, Mette; Struve, Carsten

    2009-01-01

    A novel, sensitive and specific method for detecting Rickettsia spp. in archival samples is described. The method involves the use of fluorescently marked oligonucleotide probes for in situ hybridization. Specific hybridization of Ricekttsia was found without problems of cross-reactions with bact......A novel, sensitive and specific method for detecting Rickettsia spp. in archival samples is described. The method involves the use of fluorescently marked oligonucleotide probes for in situ hybridization. Specific hybridization of Ricekttsia was found without problems of cross...

  18. Microfabricated Devices for Sample Extraction, Concentrations, and Related Sample Processing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Gang; Lin, Yuehe

    2006-12-01

    This is an invited book chapter. As with other analytical techniques, sample pretreatments, sample extraction, sample introduction, and related techniques are of extreme importance for micro-electro-mechanical systems (MEMS). Bio-MEMS devices and systems start with a sampling step. The biological sample then usually undergoes some kinds of sample preparation steps before the actual analysis. These steps may involve extracting the target sample from its matrix, removing interferences from the sample, derivatizing the sample to detectable species, or performing a sample preconcentration step. The integration of the components for sample pretreatment into microfluidic devices represents one of the remaining the bottle-neck towards achieving true miniaturized total analysis systems (?TAS). This chapter provides a thorough state-of-art of the developments in this field to date.

  19. Sample processing device and method

    DEFF Research Database (Denmark)

    2011-01-01

    A sample processing device is disclosed, which sample processing device comprises a first substrate and a second substrate, where the first substrate has a first surface comprising two area types, a first area type with a first contact angle with water and a second area type with a second contact...... angle with water, the first contact angle being smaller than the second contact angle. The first substrate defines an inlet system and a preparation system in areas of the first type which two areas are separated by a barrier system in an area of the second type. The inlet system is adapted to receive...

  20. The SHADOZ Data Base: History, Archive Web Guide, and Sample Climatologies

    Science.gov (United States)

    White, J. C.; Thompson, A. M.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    SHADOZ (Southern Hemisphere Additional Ozonesonde) is a project to augment and archive ozonesonde data from ten tropical and subtropical ozone stations. Started in 1998 by NASA's Goddard Space Flight Center and other US and international co-investigators, SHADOZ is an important tool for tropospheric ozone research in the equatorial region. The rationale for SHADOZ is to: (1) validate and improve remote sensing techniques (e.g., the Total Ozone Mapping Spectrometer (TOMS) satellite) for estimating tropical ozone, (2) contribute to climatology and trend analyses of tropical ozone and (3) provide research topics to scientists and educate students, especially in participating countries. SHADOZ is envisioned as a data service to the global scientific community by providing a central public archive location via the internet: http://code9l6.gsfc.nasa.gov/Data_services/shadoz. While the SHADOZ website maintains a standard data format for the archive, it also informs the data users on the differing stations' preparation techniques and data treatment. The presentation navigates through the SHADOZ website to access each station's sounding data and summarize each station's characteristics. Since the start of the project in 1998, the SHADOZ archive has accumulated over 600 ozonesonde profiles and received over 30,000 outside data requests. Data also includes launches from various SHADOZ supported field campaigns, such as, the Indian Ocean Experiment (INDOEX), Sounding of Ozone and Water in the Equatorial Region (SOWER) and Aerosols99 Atlantic Cruise. Using data from the archive, sample climatologies and profiles from selected stations and campaigns will be shown.

  1. An Optimized DNA Analysis Workflow for the Sampling, Extraction, and Concentration of DNA obtained from Archived Latent Fingerprints.

    Science.gov (United States)

    Solomon, April D; Hytinen, Madison E; McClain, Aryn M; Miller, Marilyn T; Dawson Cruz, Tracey

    2018-01-01

    DNA profiles have been obtained from fingerprints, but there is limited knowledge regarding DNA analysis from archived latent fingerprints-touch DNA "sandwiched" between adhesive and paper. Thus, this study sought to comparatively analyze a variety of collection and analytical methods in an effort to seek an optimized workflow for this specific sample type. Untreated and treated archived latent fingerprints were utilized to compare different biological sampling techniques, swab diluents, DNA extraction systems, DNA concentration practices, and post-amplification purification methods. Archived latent fingerprints disassembled and sampled via direct cutting, followed by DNA extracted using the QIAamp® DNA Investigator Kit, and concentration with Centri-Sep™ columns increased the odds of obtaining an STR profile. Using the recommended DNA workflow, 9 of the 10 samples provided STR profiles, which included 7-100% of the expected STR alleles and two full profiles. Thus, with carefully selected procedures, archived latent fingerprints can be a viable DNA source for criminal investigations including cold/postconviction cases. © 2017 American Academy of Forensic Sciences.

  2. Sample preparation and detection device for infectious agents

    Science.gov (United States)

    Miles, Robin R.; Wang, Amy W.; Fuller, Christopher K.; Lemoff, Asuncion V.; Bettencourt, Kerry A.; Yu, June

    2003-06-10

    A sample preparation and analysis device which incorporates both immunoassays and PCR assays in one compact, field-portable microchip. The device provides new capabilities in fluid and particle control which allows the building of a fluidic chip with no moving parts, thus decreasing fabrication cost and increasing the robustness of the device. The device can operate in a true continuous (not batch) mode. The device incorporates magnetohydrodynamic (MHD) pumps to move the fluid through the system, acoustic mixing and fractionation, dielectropheretic (DEP) sample concentration and purification, and on-chip optical detection capabilities.

  3. Bisulfite-Based DNA Methylation Analysis from Recent and Archived Formalin-Fixed, Paraffin Embedded Colorectal Tissue Samples.

    Science.gov (United States)

    Kalmár, Alexandra; Péterfia, Bálint; Hollósi, Péter; Wichmann, Barnabás; Bodor, András; Patai, Árpád V; Schöller, Andrea; Krenács, Tibor; Tulassay, Zsolt; Molnár, Béla

    2015-09-01

    We aimed to test the applicability of formalin-fixed and paraffin-embedded (FFPE) tissue samples for gene specific DNA methylation analysis after using two commercially available DNA isolation kits. Genomic DNA was isolated from 5 colorectal adenocarcinomas and 5 normal adjacent tissues from "recent", collected within 6 months, and "archived", collected more than 5 years ago, FFPE tissues using either High Pure FFPET DNA Isolation kit or QIAamp DNA FFPE Tissue kit. DNA methylation analysis of MAL, SFRP1 and SFRP2 genes, known to be hypermethylated in CRC, was performed using methylation-sensitive high resolution melting (MS-HRM) analysis and sequencing. QIAamp (Q) method resulted in slightly higher recovery in archived (HP: 1.22 ± 3.18 μg DNA; Q: 3.00 ± 4.04 μg DNA) and significantly (p < 0.05) higher recovery in recent samples compared to High Pure method (HP) (HP: 4.10 ± 2.91 μg DNA; Q: 11.51 ± 7.50 μg DNA). Both OD260/280 and OD260/230 ratios were lower, but still high in the High Pure isolated archived and recent samples compared to those isolated with QIAamp. Identical DNA methylation patterns were detected for all 3 genes tested by MS-HRM with both isolation kits in the recent group. However, despite of higher DNA recovery in QIAamp slightly more reproducible methylation results were obtained from High Pure isolated archived samples. Sequencing confirmed DNA hypermethylation in CRCs. In conclusion, reproducible DNA methylation patterns were obtained from recent samples using both isolation kits. However, long term storage may affect the reliability of the results leading to moderate differences between the efficiency of isolation kits.

  4. Improvement of fuel sampling device for STACY and TRACY

    International Nuclear Information System (INIS)

    Hirose, Hideyuki; Sakuraba, Koichi; Onodera, Seiji

    1998-05-01

    STACY and TRACY, static and transient experiment facilities in NUCEF, use solution fuel. It is important to analyze accurately fuel composition (uranium enrichment, uranium concentration, nitric acid morality, amount of impurities, radioactivity of FP) for their safety operation and improvement of experimental accuracy. Both STACY and TRACY have the sampling devices to sample fuel solution for that purpose. The previous sampling devices of STACY and TRACY had been designed to dilute fuel sample with nitric acid. Its sampling mechanism could pour fuel sample into sampling vessel by a piston drive of nitric acid in the burette. It was, however, sometimes found that sample fuel solution was diluted by mixing with nitric acid in the burette. Therefore, the sampling mechanism was change into a fixed quantity pump drive which didn't use nitric acid. The authors confirmed that the performance of the new sampling device was improved by changing sampling mechanism. It was confirmed through the function test that the uncertainty in uranium concentration measurement using the improved sampling device was 0.14%, and less than the designed value of 0.2% (coefficient of variation). (author)

  5. Develop of omni-tritium sample preparation device

    International Nuclear Information System (INIS)

    Tian Junhua; Zheng Min; Zhang Dong

    2008-06-01

    The content of total tritium analysis is required in order to know the tritium contaminated degree of biological samples accurately. But the conversion and collection of organic tritium are difficult. A device to treat total tritium samples was developed. Plant samples were treated by combustion and catalysis. After expelling the free HTO in the samples when heated in abundant oxygen, the samples were ignited. Combustion gas passed the catalysts at 800 degree C and its oxidation was catalyzed, and then the combined tritium in tissues was converted into HTO. HTO was collected by water-cooling tube and condenser. For other samples, HTO was treated and collected by high temperature (The highest temperature is 1000 degree C)-catalysis-double condensation method. This device had solved the problem that organic tritium is difficult to gather. (authors)

  6. 30 CFR 90.206 - Approved sampling devices; equivalent concentrations.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; equivalent... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.206 Approved sampling devices; equivalent...

  7. Tube closure device, especially for sample irradiation

    International Nuclear Information System (INIS)

    Klahn, F.C.; Nolan, J.H.; Wills, C.

    1979-01-01

    Device for closing the outlet of a bore and temporarily locking components in this bore. Specifically, it concerns a device for closing a tube containing a set of samples for monitoring irradiation in a nuclear reactor [fr

  8. Digital video recording and archiving in ophthalmic surgery

    Directory of Open Access Journals (Sweden)

    Raju Biju

    2006-01-01

    Full Text Available Currently most ophthalmic operating rooms are equipped with an analog video recording system [analog Charge Couple Device camera for video grabbing and a Video Cassette Recorder for recording]. We discuss the various advantages of a digital video capture device, its archiving capabilities and our experience during the transition from analog to digital video recording and archiving. The basic terminology and concepts related to analog and digital video, along with the choice of hardware, software and formats for archiving are discussed.

  9. Device for sampling HTGR recycle fuel particles

    International Nuclear Information System (INIS)

    Suchomel, R.R.; Lackey, W.J.

    1977-03-01

    Devices for sampling High-Temperature Gas-Cooled Reactor fuel microspheres were evaluated. Analysis of samples obtained with each of two specially designed passive samplers were compared with data generated by more common techniques. A ten-stage two-way sampler was found to produce a representative sample with a constant batch-to-sample ratio

  10. Water sampling device for fuel rod failure monitoring

    International Nuclear Information System (INIS)

    Oogami, Hideaki; Echigoya, Hironori; Matsuoka, Tesshi.

    1991-01-01

    The device of the present invention accurately samples coolants in a channel box as sampling water even if the upper end of the channel box of a fuel assembly is positioned at the same height or lower than the upper end of an upper lattice plate. An existent device comprises an outer cap, an inner cap, an air supply pipe and a water sampling tube. In addition, the device of the present invention comprises a sealing material disposed at the end of the outer cap for keeping liquid sealing with the upper lattice plate and a water level monitoring pipe extended to lower than the inner cap passing through the liquid sealing of the outer cap for sucking the atmosphere in the outer cap. Pressurized air is sent through the air supply pipe, to lower the water level of the coolants in the outer cap and the water level monitoring pipe sucks the pressurized air, by which the inside and the outside of the channel box are partitioned. Subsequently, if the sample water is sampled by a sampling tube, sampling water which enables accurate evaluation for radioactivity concentration in the fuel assembly can be obtained. (I.S.)

  11. Archive-cup insert for liquid-metal sampling

    International Nuclear Information System (INIS)

    Nelson, P.A.; Kolba, V.M.; Filewicz, E.C.; Holmes, J.T.

    1975-01-01

    An insert for collecting liquid-metal samples within a vertical casing including an elongated housing with an upper and a lower overflow seal of annular shape is described. The lower seal includes a centrally located pedestal on which a sample cup is disposed. Liquid metal enters the annulus of the upper seal and overflows into the cup which fills and overflows into the lower seal. Liquid-metal overflow from the lower seal is discharged from the insert. On cooling, the liquid metal trapped within the seals solidifies to hermetically isolate the metal sample within the cup. The device is particularly applicable for use with sampling systems on liquid metal-cooled reactors. (U.S.)

  12. 30 CFR 90.204 - Approved sampling devices; maintenance and calibration.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; maintenance and... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.204 Approved sampling devices; maintenance and...

  13. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate...

  14. A device for fresh water sampling before radioactive measurements

    International Nuclear Information System (INIS)

    Maubert, Henri; Picat, Philippe.

    1982-06-01

    On account of the many field operations carried out by the laboratory, a water sampling device has been developed. This portable autonomous device performs in situ water filtration and concentration on ion exchange resins and activated carbon columns. The device is described and the trapping performance for 8 radionuclides is given. A comparison is made with the so-called evaporation method. The effects of the treatment of the filtrating elements on the radioactive results are studied. This sampling method is very sensitive [fr

  15. STP K Basin Sludge Sample Archive at the Pacific Northwest National Laboratory FY2014

    Energy Technology Data Exchange (ETDEWEB)

    Fiskum, Sandra K.; Smoot, Margaret R.; Schmidt, Andrew J.

    2014-06-01

    The Pacific Northwest National Laboratory (PNNL) currently houses 88 samples (~10.5 kg) of K Basin sludge (81 wet and seven dry samples) on behalf of the Sludge Treatment Project (STP), which is managed for the U.S. Department of Energy (DOE) by the CH2M Hill Plateau Remediation Company (CHPRC). Selected samples are intended to serve, in part, as sentinels to enhance understanding of sludge properties after long-term storage, and thus enhance understanding of sludge behavior following transfer to sludge transfer and storage containers (STSCs) and storage at the Hanford 200 Area central plateau. In addition, remaining samples serve in contingency for future testing requirements. At PNNL, the samples are tracked and maintained under a prescriptive and disciplined monthly sample-monitoring program implemented by PNNL staff. This report updates the status of the K Basin archive sludge sample inventory to April 2014. The previous inventory status report, PNNL 22245 (Fiskum et al. 2013, limited distribution report), was issued in February of 2013. This update incorporates changes in the inventory related to repackaging of 17 samples under test instructions 52578 TI052, K Basin Sludge Sample Repackaging for Continued Long Term Storage, and 52578 TI053, K Basin Sludge Sample Repackaging Post-2014 Shear Strength Measurements. Note that shear strength measurement results acquired in 2014 are provided separately. Specifically, this report provides the following: • a description of the K Basin sludge sample archive program and the sample inventory • a summary and images of the samples that were repackaged in April 2014 • up-to-date images and plots of the settled density and water loss from all applicable samples in the inventory • updated sample pedigree charts, which provide a roadmap of the genesis and processing history of each sample in the inventory • occurrence and deficiency reports associated with sample storage and repackaging

  16. Archival storage solutions for PACS

    Science.gov (United States)

    Chunn, Timothy

    1997-05-01

    While they are many, one of the inhibitors to the wide spread diffusion of PACS systems has been robust, cost effective digital archive storage solutions. Moreover, an automated Nearline solution is key to a central, sharable data repository, enabling many applications such as PACS, telemedicine and teleradiology, and information warehousing and data mining for research such as patient outcome analysis. Selecting the right solution depends on a number of factors: capacity requirements, write and retrieval performance requirements, scaleability in capacity and performance, configuration architecture and flexibility, subsystem availability and reliability, security requirements, system cost, achievable benefits and cost savings, investment protection, strategic fit and more.This paper addresses many of these issues. It compares and positions optical disk and magnetic tape technologies, which are the predominant archive mediums today. Price and performance comparisons will be made at different archive capacities, plus the effect of file size on storage system throughput will be analyzed. The concept of automated migration of images from high performance, high cost storage devices to high capacity, low cost storage devices will be introduced as a viable way to minimize overall storage costs for an archive. The concept of access density will also be introduced and applied to the selection of the most cost effective archive solution.

  17. Device for radioactivity measurement of liquid samples

    International Nuclear Information System (INIS)

    Lamaziere, J.

    1983-01-01

    The device for low activity gamma measurements comprises an automatic changer for sample transfer from a conveyor to a measuring chamber. The conveyor includes a horizontal table were are regularly distributed sample holders. A lift allows a vertical motion of a plate for the exposition in front of a detector [fr

  18. Dose-Response Analysis of RNA-Seq Profiles in Archival Formalin-Fixed Paraffin-Embedded (FFPE) Samples.

    Science.gov (United States)

    Use of archival resources has been limited to date by inconsistent methods for genomic profiling of degraded RNA from formalin-fixed paraffin-embedded (FFPE) samples. RNA-sequencing offers a promising way to address this problem. Here we evaluated transcriptomic dose responses us...

  19. The effects of age-in-block on RNA-seq analysis of archival formalin-fixed paraffin-embedded (FFPE) samples

    Science.gov (United States)

    Archival samples represent a vast resource for identification of chemical and pharmaceutical targets. Previous use of formalin-fixed paraffin-embedded (FFPE) samples has been limited due to changes in RNA introduced by fixation and embedding procedures. Recent advances in RNA-seq...

  20. Medical image digital archive: a comparison of storage technologies

    Science.gov (United States)

    Chunn, Timothy; Hutchings, Matt

    1998-07-01

    A cost effective, high capacity digital archive system is one of the remaining key factors that will enable a radiology department to eliminate film as an archive medium. The ever increasing amount of digital image data is creating the need for huge archive systems that can reliably store and retrieve millions of images and hold from a few terabytes of data to possibly hundreds of terabytes. Selecting the right archive solution depends on a number of factors: capacity requirements, write and retrieval performance requirements, scaleability in capacity and performance, conformance to open standards, archive availability and reliability, security, cost, achievable benefits and cost savings, investment protection, and more. This paper addresses many of these issues. It compares and positions optical disk and magnetic tape technologies, which are the predominant archive mediums today. New technologies will be discussed, such as DVD and high performance tape. Price and performance comparisons will be made at different archive capacities, plus the effect of file size on random and pre-fetch retrieval time will be analyzed. The concept of automated migration of images from high performance, RAID disk storage devices to high capacity, NearlineR storage devices will be introduced as a viable way to minimize overall storage costs for an archive.

  1. Sampling device for withdrawing a representative sample from single and multi-phase flows

    Science.gov (United States)

    Apley, Walter J.; Cliff, William C.; Creer, James M.

    1984-01-01

    A fluid stream sampling device has been developed for the purpose of obtaining a representative sample from a single or multi-phase fluid flow. This objective is carried out by means of a probe which may be inserted into the fluid stream. Individual samples are withdrawn from the fluid flow by sampling ports with particular spacings, and the sampling parts are coupled to various analytical systems for characterization of the physical, thermal, and chemical properties of the fluid flow as a whole and also individually.

  2. Test plan for K Basin Sludge Canister and Floor Sampling Device

    International Nuclear Information System (INIS)

    Meling, T.A.

    1995-01-01

    This document provides the test plan and procedure forms for conducting the functional and operational acceptance testing of the K Basin Sludge Canister and Floor Sampling Device(s). These samplers samples sludge off the floor of the 100K Basins and out of 100K fuel storage canisters

  3. 21 CFR 892.2050 - Picture archiving and communications system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Picture archiving and communications system. 892... communications system. (a) Identification. A picture archiving and communications system is a device that... processing of medical images. Its hardware components may include workstations, digitizers, communications...

  4. Development of a magnetic measurement device for thin ribbon samples

    International Nuclear Information System (INIS)

    Sato, Yuta; Todaka, Takashi; Enokizono, Masato

    2008-01-01

    This paper presents a magnetic measurement device for thin ribbon samples, which are produced by rapid cooling technique. This device enables us to measure magnetic properties easily by only inserting a ribbon sample into a sample holder. The sample holder was made by bakelite to fix any width sample. A long solenoid coil was used to generate a uniform magnetic field and the sample holder was placed at the mid part of the solenoid. The magnetic field strength was measured using a shunt resistor and the magnetic flux density and magnetization in sample ribbons were evaluated by using search coils. The accuracy of measurement was verified with an amorphous metal ribbon sample. Next, we have measured magnetic properties of some magnetic shape memory alloys, which have different compositions. The measured results are compared and we clarified the effect of Sm contents on the magnetic properties

  5. RAPID PROCESSING OF ARCHIVAL TISSUE SAMPLES FOR PROTEOMIC ANALYSIS USING PRESSURE-CYCLING TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Vinuth N. Puttamallesh1,2

    2017-06-01

    Full Text Available Advent of mass spectrometry based proteomics has revolutionized our ability to study proteins from biological specimen in a high-throughput manner. Unlike cell line based studies, biomedical research involving tissue specimen is often challenging due to limited sample availability. In addition, investigation of clinically relevant research questions often requires enormous amount of time for sample collection prospectively. Formalin fixed paraffin embedded (FFPE archived tissue samples are a rich source of tissue specimen for biomedical research. However, there are several challenges associated with analysing FFPE samples. Protein cross-linking and degradation of proteins particularly affects proteomic analysis. We demonstrate that barocycler that uses pressure-cycling technology enables efficient protein extraction and processing of small amounts of FFPE tissue samples for proteomic analysis. We identified 3,525 proteins from six 10µm esophageal squamous cell carcinoma (ESCC tissue sections. Barocycler allows efficient protein extraction and proteolytic digestion of proteins from FFPE tissue sections at par with conventional methods.

  6. Attitudes of the Japanese public and doctors towards use of archived information and samples without informed consent: Preliminary findings based on focus group interviews

    Directory of Open Access Journals (Sweden)

    Fukuhara Shunichi

    2002-01-01

    Full Text Available Abstract Background The purpose of this study is to explore laypersons' attitudes toward the use of archived (existing materials such as medical records and biological samples and to compare them with the attitudes of physicians who are involved in medical research. Methods Three focus group interviews were conducted, in which seven Japanese male members of the general public, seven female members of the general public and seven physicians participated. Results It was revealed that the lay public expressed diverse attitudes towards the use of archived information and samples without informed consent. Protecting a subject's privacy, maintaining confidentiality, and communicating the outcomes of studies to research subjects were regarded as essential preconditions if researchers were to have access to archived information and samples used for research without the specific informed consent of the subjects who provided the material. Although participating physicians thought that some kind of prior permission from subjects was desirable, they pointed out the difficulties involved in obtaining individual informed consent in each case. Conclusions The present preliminary study indicates that the lay public and medical professionals may have different attitudes towards the use of archived information and samples without specific informed consent. This hypothesis, however, is derived from our focus groups interviews, and requires validation through research using a larger sample.

  7. microRNA Biomarker Discovery and High-Throughput DNA Sequencing Are Possible Using Long-term Archived Serum Samples.

    Science.gov (United States)

    Rounge, Trine B; Lauritzen, Marianne; Langseth, Hilde; Enerly, Espen; Lyle, Robert; Gislefoss, Randi E

    2015-09-01

    The impacts of long-term storage and varying preanalytical factors on the quality and quantity of DNA and miRNA from archived serum have not been fully assessed. Preanalytical and analytical variations and degradation may introduce bias in representation of DNA and miRNA and may result in loss or corruption of quantitative data. We have evaluated DNA and miRNA quantity, quality, and variability in samples stored up to 40 years using one of the oldest prospective serum collections in the world, the Janus Serumbank, a biorepository dedicated to cancer research. miRNAs are present and stable in archived serum samples frozen at -25°C for at least 40 years. Long-time storage did not reduce miRNA yields; however, varying preanalytical conditions had a significant effect and should be taken into consideration during project design. Of note, 500 μL serum yielded sufficient miRNA for qPCR and small RNA sequencing and on average 650 unique miRNAs were detected in samples from presumably healthy donors. Of note, 500 μL serum yielded sufficient DNA for whole-genome sequencing and subsequent SNP calling, giving a uniform representation of the genomes. DNA and miRNA are stable during long-term storage, making large prospectively collected serum repositories an invaluable source for miRNA and DNA biomarker discovery. Large-scale biomarker studies with long follow-up time are possible utilizing biorepositories with archived serum and state-of-the-art technology. ©2015 American Association for Cancer Research.

  8. Paper Capillary Enables Effective Sampling for Microfluidic Paper Analytical Devices.

    Science.gov (United States)

    Shangguan, Jin-Wen; Liu, Yu; Wang, Sha; Hou, Yun-Xuan; Xu, Bi-Yi; Xu, Jing-Juan; Chen, Hong-Yuan

    2018-06-06

    Paper capillary is introduced to enable effective sampling on microfluidic paper analytical devices. By coupling mac-roscale capillary force of paper capillary and microscale capillary forces of native paper, fluid transport can be flexibly tailored with proper design. Subsequently, a hybrid-fluid-mode paper capillary device was proposed, which enables fast and reliable sampling in an arrayed form, with less surface adsorption and bias for different components. The resulting device thus well supports high throughput, quantitative, and repeatable assays all by hands operation. With all these merits, multiplex analysis of ions, proteins, and microbe have all been realized on this platform, which has paved the way to level-up analysis on μPADs.

  9. Archived neonatal dried blood spot samples can be used for accurate whole genome and exome-targeted next-generation sequencing

    DEFF Research Database (Denmark)

    Hollegaard, Mads Vilhelm; Grauholm, Jonas; Nielsen, Ronni

    2013-01-01

    Dried blood spot samples (DBSS) have been collected and stored for decades as part of newborn screening programmes worldwide. Representing almost an entire population under a certain age and collected with virtually no bias, the Newborn Screening Biobanks are of immense value in medical studies......, for example, to examine the genetics of various disorders. We have previously demonstrated that DNA extracted from a fraction (2×3.2mm discs) of an archived DBSS can be whole genome amplified (wgaDNA) and used for accurate array genotyping. However, until now, it has been uncertain whether wgaDNA from DBSS...... can be used for accurate whole genome sequencing (WGS) and exome sequencing (WES). This study examined two individuals represented by three different types of samples each: whole-blood (reference samples), 3-year-old DBSS spotted with reference material (refDBSS), and 27- to 29-year-old archived...

  10. The Wismut biosample archive in the occupational medical research. Pathological and molecular epidemiological archive

    International Nuclear Information System (INIS)

    Bruening, Thomas; Johnen, Georg

    2015-01-01

    Worldwide only few biosample archives exist that focus on samples from employees with occupational exposures, especially radiation exposure. The Wismut biosample archive of former uranium miners is a valuable resource for the occupational medical research.

  11. Combining Electro-Osmotic Flow and FTA® Paper for DNA Analysis on Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ryan Wimbles

    2016-07-01

    Full Text Available FTA® paper can be used to protect a variety of biological samples prior to analysis, facilitating ease-of-transport to laboratories or long-term archive storage. The use of FTA® paper as a solid phase eradicates the need to elute the nucleic acids from the matrix prior to DNA amplification, enabling both DNA purification and polymerase chain reaction (PCR-based DNA amplification to be performed in a single chamber on the microfluidic device. A disc of FTA® paper, containing a biological sample, was placed within the microfluidic device on top of wax-encapsulated DNA amplification reagents. The disc containing the biological sample was then cleaned up using Tris-EDTA (TE buffer, which was passed over the disc, via electro-osmotic flow, in order to remove any potential inhibitors of downstream processes. DNA amplification was successfully performed (from buccal cells, whole blood and semen using a Peltier thermal cycling system, whereupon the stored PCR reagents were released during the initial denaturing step due to the wax barrier melting between the FTA® disc and PCR reagents. Such a system offers advantages in terms of a simple sample introduction interface and the ability to process archived samples in an integrated microfluidic environment with minimal risk of contamination.

  12. Air-deployable oil spill sampling devices review phase 2 testing. Volume 1

    International Nuclear Information System (INIS)

    Hawke, L.; Dumouchel, A.; Fingas, M.; Brown, C.E.

    2007-01-01

    SAIC Canada tested air deployable oil sampling devices for the Emergencies Science and Technology Division of Environment Canada in order to determine the applicability and status of these devices. The 3 devices tested were: Canada's SABER (sampling autonomous buoy for evidence recovery), the United States' POPEIE (probe for oil pollution evidence in the environment); and, Sweden's SAR Floatation 2000. They were tested for buoyancy properties, drift behaviour and sampler sorbent pickup ratios. The SAR and SABER both had lesser draft and greater freeboard, while the POPEIE had much greater draft than freeboard. All 3 devices could be used for oil sample collection in that their drift characteristics would allow for the SABER and SAR devices to be placed upwind of the slick while the POPEIE device could be placed downwind of an oil spill. The sorbent testing revealed that Sefar sorbent and Spectra sorbent used in the 3 devices had negative pickup ratios for diesel but performance improved as oil viscosity increased. Both sorbents are inert and capable of collecting oil in sufficient volumes for consistent fingerprinting analysis. 10 refs., 8 tabs., 8 figs

  13. Measurements of CO2 Mole Fractionand δ13C in Archived Air Samples from Cape Meares, Oregon (USA) 1977 - 1998

    Science.gov (United States)

    Clark, O.; Rice, A. L.

    2017-12-01

    Carbon dioxide (CO2) is the most abundant, anthropogenically forced greenhouse gas (GHG) in the global atmosphere. Emissions of CO2 account for approximately 75% of the world's total GHG emissions. Atmospheric concentrations of CO2 are higher now than they've been at any other time in the past 800,000 years. Currently, the global mean concentration exceeds 400 ppm. Today, global networks regularly monitor CO2 concentrations and isotopic composition (δ13C and δ18O). However, past data is sparse. Over 200 ambient air samples from Cape Meares, Oregon (45.5°N, 124.0°W), a coastal site in Western United States, were obtained by researchers at Oregon Institute of Science and Technology (OGI, now Oregon Health & Science University), between the years of 1977 and 1998 as part of a global monitoring program of six different sites in the polar, middle, and tropical latitudes of the Northern and Southern Hemispheres. Air liquefaction was used to compress approximately 1000L of air (STP) to 30bar, into 33L electropolished (SUMMA) stainless steel canisters. Select archived air samples from the original network are maintained at Portland State University (PSU) Department of Physics. These archived samples are a valuable look at changing atmospheric concentrations of CO2 and δ13C, which can contribute to a better understanding of changes in sources during this time. CO2 concentrations and δ13C of CO2 were measured at PSU, with a Picarro Cavity Ringdown Spectrometer, model G1101-i analytical system. This study presents the analytical methods used, calibration techniques, precision, and reproducibility. Measurements of select samples from the archive show rising CO2 concentrations and falling δ13C over the 1977 to 1998 period, compatible with previous observations and rising anthropogenic sources of CO2. The resulting data set was statistically analyzed in MATLAB. Results of preliminary seasonal and secular trends from the archive samples are presented.

  14. 78 FR 25308 - Proposed Collection; Comment Request; Coal Mine Dust Sampling Devices

    Science.gov (United States)

    2013-04-30

    ...; Coal Mine Dust Sampling Devices AGENCY: Mine Safety and Health Administration, Labor. ACTION: 60-Day... mines. CPDMs must be designed and constructed for coal miners to wear and operate without impeding their... related to Coal Mine Dust Sampling Devices. MSHA is particularly interested in comments that: Evaluate...

  15. Device for sampling radioactive and aggressive liquid and vaporous media

    International Nuclear Information System (INIS)

    Przibram, E.; Halm, G.

    1974-01-01

    The equipment enables the taking of samples even of radioactive media from a main pipeline in the through-flow in a closed system. A tap device is attached to the main pipeline which branches into two parts. The one branch contains the actual tap which is closed to both sides with snap closure coupling. It is only used for taking samples. The other branch bridges the tap position as a bypass so that a representative sample is always available. Both branches join up again and lead back to the main pipeline. The sampling can be used in a nuclear power plant for the determination of O 2 , CI, SiO 2 , and Cu. A millilitre collecting cylinder and a millipore filtration device can be connected to the tap for liquid sampling and solid analysis, respectively. The system can be extended to several tap positions. Permanent measuring equipment is attached to the bypass pipe to control the sample liquid. (DG) [de

  16. Data archiving system implementation in ITER's CODAC Core System

    International Nuclear Information System (INIS)

    Castro, R.; Abadie, L.; Makushok, Y.; Ruiz, M.; Sanz, D.; Vega, J.; Faig, J.; Román-Pérez, G.; Simrock, S.; Makijarvi, P.

    2015-01-01

    Highlights: • Implementation of ITER's data archiving solution. • Integration of the solution into CODAC Core System. • Data archiving structure. • High efficient data transmission into fast plant system controllers. • Fast control and data acquisition in Linux. - Abstract: The aim of this work is to present the implementation of data archiving in ITER's CODAC Core System software. This first approach provides a client side API and server side software allowing the creation of a simplified version of ITERDB data archiving software, and implements all required elements to complete data archiving flow from data acquisition until its persistent storage technology. The client side includes all necessary components that run on devices that acquire or produce data, distributing and streaming to configure remote archiving servers. The server side comprises an archiving service that stores into HDF5 files all received data. The archiving solution aims at storing data coming for the data acquisition system, the conventional control and also processed/simulated data.

  17. Sample taking device for toxic and/or radioactive substances

    International Nuclear Information System (INIS)

    Finsterwalder, L.; Zeh, H.; Schaarschmidt, U.

    1979-01-01

    An apparatus for taking samples of toxic and/or radioactive liquid substances by introducing such substances into sample vessels includes a holder for holding such a vessel, at least one needle head filling system composed of upwardly pointing hollow needles for introducing a sample of one such substance into such a vessel at a filling position, and inlet and outlet conduits for pneumatically conveying vessels to or from the holder at a transfer position. The holder is composed of a turntable having a sleeve for accommodating such vessel and is mounted to undergo rotary movement to convey a sample vessel held in the sleeve between the filling and transfer positions. The apparatus further includes a stand supporting the filling system below the holder and a lifting device connected for imparting a translational movement to the holder to bring a vessel in the holder to operative association with the filling system. The lifting device is arranged so that the translational movement which it produces is independent of the rotary movement of the turntable

  18. Rapid Surface Sampling and Archival Record (RSSAR) System. Topical report, October 1, 1993--December 31, 1994

    International Nuclear Information System (INIS)

    1997-01-01

    This report describes the results of Phase 1 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large tacks of concern to both government and industry. Contaminated and clean materials must be clearly identified and segregated so that the clean materials can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmatory process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible. Aware of the shortcomings of traditional surface characterization technology, GE, with DOE support has undertaken a 12-month effort to complete Phase 1 of a proposed four-phase program to develop the RSSAR system. The objectives of this work are to provide instrumentation to cost-effectively sample concrete and steel surfaces, provide a quick-look indication for the presence or absence of contaminants, and collect samples for later, more detailed analysis in a readily accessible and addressable form. The Rapid Surface Sampling and Archival Record (RSSAR) System will be a modular instrument made up of several components: (1) sampling heads for concrete surfaces, steel surfaces, and bulk samples; (2) quick-look detectors for photoionization and ultraviolet; (3) multisample trapping module to trap and store vaporized contaminants in a manner suitable for subsequent detailed lab-based analyses

  19. Accumulation of brevetoxins by passive sampling devices | Shea ...

    African Journals Online (AJOL)

    We report on initial investigations into the use of polymer-based passive sampling devices for the chronic time-integrated measure of brevetoxins in natural waters. Polyethylene membranes readily accumulated brevetoxins, but reached steady state within a few days, likely owing to surface saturation on the polyethylene ...

  20. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  1. Latex Rubber Gloves as a Sampling Dosimeter Using a Novel Surrogate Sampling Device.

    Science.gov (United States)

    Sankaran, Gayatri; Lopez, Terry; Ries, Steve; Ross, John; Vega, Helen; Eastmond, David A; Krieger, Robert I

    2015-01-01

    Pesticide exposure during harvesting of crops occurs primarily to the workers' hands. When harvesters wear latex rubber gloves for personal safety and hygiene harvesting reasons, gloves accumulate pesticide residues. Hence, characterization of the gloves' properties may be useful for pesticide exposure assessments. Controlled field studies were conducted using latex rubber gloves to define the factors that influence the transfer of pesticides to the glove and that would affect their use as a residue monitoring device. A novel sampling device called the Brinkman Contact Transfer Unit (BCTU) was constructed to study the glove characteristics and residue transfer and accumulation under controlled conditions on turf. The effectiveness of latex rubber gloves as sampling dosimeters was evaluated by measuring the transferable pesticide residues as a function of time. The validation of latex rubber gloves as a residue sampling dosimeter was performed by comparing pesticide transfer and dissipation from the gloves, with the turf transferable residues sampled using the validated California (CA) Roller, a standard measure of residue transfer. The observed correlation (Pearson's correlation coefficient R(2)) between the two methods was .84 for malathion and .96 for fenpropathrin, indicating that the BCTU is a useful, reliable surrogate tool for studying available residue transfer to latex rubber gloves under experimental conditions. Perhaps more importantly, these data demonstrate that latex gloves worn by workers may be useful quantifiable matrices for measuring pesticide exposure.

  2. Comparative study of the characteristics of some suction devices for gas sampling applications

    International Nuclear Information System (INIS)

    Donguy, R.; Drouet, J.

    1959-06-01

    Gas sampling (used to determine the characteristics of dusts or aerosols contained in a gas) needs a suction device. In order to select the right device and the right conditions of use, the characteristics and performances of various suction devices (helicoidal and centrifugal aspirators, air pumps, volumetric pumps) have been experimentally measured: flow rate, head loss, sampling volume and duration, aerosol and dust concentration, gas density, nature of the gas, suction circuit configuration, etc

  3. Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.

    Science.gov (United States)

    Seferaj, Sabina; Ullah, Shahid; Tinglev, Åsa; Carlsson, Sten; Winberg, Jesper; Stambeck, Peter; Beck, Olof

    2018-03-12

    The microparticle fraction of exhaled breath is of interest for developing clinical biomarkers. Exhaled particles may contain non-volatile components from all parts of the airway system, formed during normal breathing. This study aimed to evaluate a new, simple sampling device, based on impaction, for collecting microparticles from exhaled breath. Performance of the new device was compared with that of the existing SensAbues membrane filter device. The analytical work used liquid chromatography-tandem mass spectrometry methods. The new device collected three subsamples and these were separately analysed from eight individuals. No difference was observed between the centre position (0.91 ng/sample) and the side positions (1.01 ng/sample) using major phosphatidylcholine (PC) 16:0/16:0 as the analyte. Exhaled breath was collected from eight patients on methadone maintenance treatment. The intra-individual variability in measured methadone concentration between the three collectors was 8.7%. In another experiment using patients on methadone maintenance treatment, the sampling efficiency was compared with an established filter device. Compared to the existing device, the efficiency of the new device was 121% greater for methadone and 1450% greater for DPPC. The data from lipid analysis also indicated that a larger fraction of the collected material was from the distal parts. Finally, a study using an optical particle counter indicated that the device preferentially collects the larger particle fraction. In conclusion, this study demonstrates the usefulness of the new device for collecting non-volatile components from exhaled breath. The performance of the device was superior to the filter device in several aspects.

  4. Development and application of a micro-digestion device for biological samples

    International Nuclear Information System (INIS)

    Bohlen, A. von; Klockenkaemper, R.; Messerschmidt, J.; Alt, F.

    2000-01-01

    The analytical characterization of small amounts of a sample is of increasing importance for various research projects in biology, biochemistry and medicine. Reliable determinations of minor and trace elements in microsamples can be performed by total reflection x-ray fluorescence analysis (TXRF). This microanalytical method is suitable for direct multielement analyses of a tiny amount of a liquid or solid sample. Instead of a direct analysis, however, a complete digestion or mineralisation of the sample material prior to analysis can be recommendable. It can be advantageous for a favorable presentation, for a preconcentration and/or homogenization of the material and particularly for an accurate quantification. Unfortunately, commercially available digestion devices are optimized for amounts of 50 to 400 mg of a sample. For smaller amounts, a microdigestion device was constructed and adapted to an equipment of high pressure ashing, which is commercially available. Digestions of very different microsamples between some μg and some mg were carried out, followed by quantitative determinations of a lot of elements. Besides, different Standard Reference Materials (SRM) were analyzed. The homogeneity of these materials could be investigated by comparing the results found for microsamples with those obtained for samples of 200 mg, the latter after digestion in a conventional device. (author)

  5. Device for taking gaseous samples from irradiated fuel elements

    International Nuclear Information System (INIS)

    Lengacker, B.

    1983-01-01

    The described device allows to take gaseous samples from irradiated fuel elements. It is connected with a gas analyzer and a pressure gage, so that in opening the fuel can the internal pressure can be determined

  6. A low-temperature sample orienting device for single crystal spectroscopy at the SNS

    Energy Technology Data Exchange (ETDEWEB)

    Sherline, T E; Solomon, L; Roberts, C K II; Bruce, D; Gaulin, B; Granroth, G E, E-mail: sherlinete@ornl.gov

    2010-11-01

    A low temperature sample orientation device providing three axes of rotation has been successfully built and is in testing for use on several spectrometers at the spallation neutron source (SNS). Sample rotation about the vertical ({omega}) axis of nearly 360 deg. and out of plane tilts ({phi} and v) of from -3.4 deg. to 4.4 deg. and from -2.8 deg. to 3.5 deg., respectively, are possible. An off-the-shelf closed cycle refrigerator (CCR) is mounted on a room temperature sealed rotary flange providing {omega} rotations of the sample. Out-of-plane tilts are made possible by piezoelectric actuated angular positioning devices mounted on the low temperature head of the CCR. Novel encoding devices based on magnetoresistive sensors have been developed to measure the tilt stage angles. This combination facilitates single crystal investigations from room temperature to 3.1 K. Commissioning experiments of the rotating CCR for both powder and single crystal samples have been performed on the ARCS spectrometer at the SNS. For the powder sample this device was used to continuously rotate the sample and thus average out any partial orientation of the powder. The powder rings observed in S(Q) are presented. For the single crystal sample, the rotation was used to probe different regions of momentum transfer (Q-space). Laue patterns obtained from a single crystal sample at two rotation angles are presented.

  7. A medical application integrating remote 3D visualization tools to access picture archiving and communication system on mobile devices.

    Science.gov (United States)

    He, Longjun; Ming, Xing; Liu, Qian

    2014-04-01

    With computing capability and display size growing, the mobile device has been used as a tool to help clinicians view patient information and medical images anywhere and anytime. However, for direct interactive 3D visualization, which plays an important role in radiological diagnosis, the mobile device cannot provide a satisfactory quality of experience for radiologists. This paper developed a medical system that can get medical images from the picture archiving and communication system on the mobile device over the wireless network. In the proposed application, the mobile device got patient information and medical images through a proxy server connecting to the PACS server. Meanwhile, the proxy server integrated a range of 3D visualization techniques, including maximum intensity projection, multi-planar reconstruction and direct volume rendering, to providing shape, brightness, depth and location information generated from the original sectional images for radiologists. Furthermore, an algorithm that changes remote render parameters automatically to adapt to the network status was employed to improve the quality of experience. Finally, performance issues regarding the remote 3D visualization of the medical images over the wireless network of the proposed application were also discussed. The results demonstrated that this proposed medical application could provide a smooth interactive experience in the WLAN and 3G networks.

  8. A novel needle-type sampling device for flexible ultrathin bronchoscopy

    International Nuclear Information System (INIS)

    Suda, Yuji; Hayashi, Katsutoshi; Shindoh, Yuriko; Iijima, Hideya; Tanaka, Akiko

    2008-01-01

    Diagnosis of suspected cancer in the periphery of the lung is difficult. A flexible ultrathin bronchoscope has been developed for the diagnosis of peripherally located pulmonary lesions that cannot be reached with the sampling devices for standard flexible bronchoscopes. The diagnostic yield with forceps and a brush for ultrathin bronchoscopes, however, is not adequate, especially when a lesion is not exposed to the bronchial lumen. We have thus developed a novel needle-type sampling device and tested its yield in transbronchial cytology. The device consists of an elongated dental H-file (0.4 mm in diameter and 110 cm in length), a housing sheath (1.0 mm in outer diameter), and a novel handle, which enables rapid out-and-in motion of the needle. Ten consecutive patients with a peripheral pulmonary lesion who had an indication for diagnostic procedure with a flexible ultrathin bronchoscope were enrolled. The optimal bronchial route to the lesion was analyzed with virtual bronchoscopy in a data set obtained with high-resolution computed tomography, and a novel bronchial route labeling system (prior-ridge-based relative orientation nomenclature) was employed to guide insertion of the bronchoscope. Sampling with the novel needle was performed prior to use of the forceps and brush under conventional fluoroscopy. In all the cases, sampling with the needle was successful and the amount of the specimen was sufficient for cytology. Our novel sampling system with flexible ultrathin bronchoscopes may contribute to accurate and minimally invasive diagnosis of peripheral pulmonary lesions. (author)

  9. Microfluidic devices for sample preparation and rapid detection of foodborne pathogens.

    Science.gov (United States)

    Kant, Krishna; Shahbazi, Mohammad-Ali; Dave, Vivek Priy; Ngo, Tien Anh; Chidambara, Vinayaka Aaydha; Than, Linh Quyen; Bang, Dang Duong; Wolff, Anders

    2018-03-10

    Rapid detection of foodborne pathogens at an early stage is imperative for preventing the outbreak of foodborne diseases, known as serious threats to human health. Conventional bacterial culturing methods for foodborne pathogen detection are time consuming, laborious, and with poor pathogen diagnosis competences. This has prompted researchers to call the current status of detection approaches into question and leverage new technologies for superior pathogen sensing outcomes. Novel strategies mainly rely on incorporating all the steps from sample preparation to detection in miniaturized devices for online monitoring of pathogens with high accuracy and sensitivity in a time-saving and cost effective manner. Lab on chip is a blooming area in diagnosis, which exploits different mechanical and biological techniques to detect very low concentrations of pathogens in food samples. This is achieved through streamlining the sample handling and concentrating procedures, which will subsequently reduce human errors and enhance the accuracy of the sensing methods. Integration of sample preparation techniques into these devices can effectively minimize the impact of complex food matrix on pathogen diagnosis and improve the limit of detections. Integration of pathogen capturing bio-receptors on microfluidic devices is a crucial step, which can facilitate recognition abilities in harsh chemical and physical conditions, offering a great commercial benefit to the food-manufacturing sector. This article reviews recent advances in current state-of-the-art of sample preparation and concentration from food matrices with focus on bacterial capturing methods and sensing technologies, along with their advantages and limitations when integrated into microfluidic devices for online rapid detection of pathogens in foods and food production line. Copyright © 2018. Published by Elsevier Inc.

  10. Microfluidic devices for sample preparation and rapid detection of foodborne pathogens

    DEFF Research Database (Denmark)

    Kant, Krishna; Shahbazi, Mohammad-Ali; Dave, Vivek Priy

    2018-01-01

    and improve the limit of detections. Integration of pathogen capturing bio-receptors on microfluidic devices is a crucial step, which can facilitate recognition abilities in harsh chemical and physical conditions, offering a great commercial benefit to the food-manufacturing sector. This article reviews...... diagnosis competences. This has prompted researchers to call the current status of detection approaches into question and leverage new technologies for superior pathogen sensing outcomes. Novel strategies mainly rely on incorporating all the steps from sample preparation to detection in miniaturized devices...... recent advances in current state-of-the-art of sample preparation and concentration from food matrices with focus on bacterial capturing methods and sensing technologies, along with their advantages and limitations when integrated into microfluidic devices for online rapid detection of pathogens in foods...

  11. Data archiving system implementation in ITER's CODAC Core System

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R., E-mail: rodrigo.castro@visite.es [CIEMAT Fusion Program, Avda. Complutense 40, Madrid (Spain); Abadie, L. [ITER Organization, Route de Vinon-sur-Verdon, 13115 St. Paul-lez-Durance (France); Makushok, Y. [Sgenia, C/Chile, 4 Edificio II, Las Rozas, Madrid (Spain); Ruiz, M.; Sanz, D. [Instrumentation and Applied Acoustic Research Group, Technical University of Madrid, Madrid (Spain); Vega, J. [CIEMAT Fusion Program, Avda. Complutense 40, Madrid (Spain); Faig, J. [INDRA Sistemas, S.A. Unid. de Sistemas de Control, Dirección de Tecnología Energética, Madrid (Spain); Román-Pérez, G. [Sgenia, C/Chile, 4 Edificio II, Las Rozas, Madrid (Spain); Simrock, S.; Makijarvi, P. [ITER Organization, Route de Vinon-sur-Verdon, 13115 St. Paul-lez-Durance (France)

    2015-10-15

    Highlights: • Implementation of ITER's data archiving solution. • Integration of the solution into CODAC Core System. • Data archiving structure. • High efficient data transmission into fast plant system controllers. • Fast control and data acquisition in Linux. - Abstract: The aim of this work is to present the implementation of data archiving in ITER's CODAC Core System software. This first approach provides a client side API and server side software allowing the creation of a simplified version of ITERDB data archiving software, and implements all required elements to complete data archiving flow from data acquisition until its persistent storage technology. The client side includes all necessary components that run on devices that acquire or produce data, distributing and streaming to configure remote archiving servers. The server side comprises an archiving service that stores into HDF5 files all received data. The archiving solution aims at storing data coming for the data acquisition system, the conventional control and also processed/simulated data.

  12. 78 FR 27442 - Coal Mine Dust Sampling Devices; Correction

    Science.gov (United States)

    2013-05-10

    ... DEPARTMENT OF LABOR Mine Safety and Health Administration Coal Mine Dust Sampling Devices; Correction AGENCY: Mine Safety and Health Administration, Labor. ACTION: Notice; correction. SUMMARY: On April 30, 2013, Mine Safety and Health Administration (MSHA) published a notice in the Federal Register...

  13. Bio-sample detection on paper-based devices with inkjet printer-sprayed reagents.

    Science.gov (United States)

    Liang, Wun-Hong; Chu, Chien-Hung; Yang, Ruey-Jen

    2015-12-01

    The reagent required for bio-sample detection on paper-based analytical devices is generally introduced manually using a pipette. Such an approach is time-consuming; particularly if a large number of devices are required. Automated methods provide a far more convenient solution for large-scale production, but incur a substantial cost. Accordingly, the present study proposes a low-cost method for the paper-based analytical devices in which the biochemical reagents are sprayed onto the device directly using a modified commercial inkjet printer. The feasibility of the proposed method is demonstrated by performing aspartate aminotransferase (AST) and alanine aminotransferase (ALT) tests using simple two-dimensional (2D) paper-based devices. In both cases, the reaction process is analyzed using an image-processing-based colorimetric method. The experimental results show that for AST detection within the 0-105 U/l concentration range, the optimal observation time is around four minutes, while for ALT detection in the 0-125 U/l concentration range, the optimal observation time is approximately one minute. Finally, for both samples, the detection performance of the sprayed-reagent analytical devices is insensitive to the glucose concentration. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. A Waveform Archiving System for the GE Solar 8000i Bedside Monitor.

    Science.gov (United States)

    Fanelli, Andrea; Jaishankar, Rohan; Filippidis, Aristotelis; Holsapple, James; Heldt, Thomas

    2018-01-01

    Our objective was to develop, deploy, and test a data-acquisition system for the reliable and robust archiving of high-resolution physiological waveform data from a variety of bedside monitoring devices, including the GE Solar 8000i patient monitor, and for the logging of ancillary clinical and demographic information. The data-acquisition system consists of a computer-based archiving unit and a GE Tram Rac 4A that connects to the GE Solar 8000i monitor. Standard physiological front-end sensors connect directly to the Tram Rac, which serves as a port replicator for the GE monitor and provides access to these waveform signals through an analog data interface. Together with the GE monitoring data streams, we simultaneously collect the cerebral blood flow velocity envelope from a transcranial Doppler ultrasound system and a non-invasive arterial blood pressure waveform along a common time axis. All waveform signals are digitized and archived through a LabView-controlled interface that also allows for the logging of relevant meta-data such as clinical and patient demographic information. The acquisition system was certified for hospital use by the clinical engineering team at Boston Medical Center, Boston, MA, USA. Over a 12-month period, we collected 57 datasets from 11 neuro-ICU patients. The system provided reliable and failure-free waveform archiving. We measured an average temporal drift between waveforms from different monitoring devices of 1 ms every 66 min of recorded data. The waveform acquisition system allows for robust real-time data acquisition, processing, and archiving of waveforms. The temporal drift between waveforms archived from different devices is entirely negligible, even for long-term recording.

  15. Polymeric ionic liquid-based portable tip microextraction device for on-site sample preparation of water samples.

    Science.gov (United States)

    Chen, Lei; Pei, Junxian; Huang, Xiaojia; Lu, Min

    2018-06-05

    On-site sample preparation is highly desired because it avoids the transportation of large-volume samples and ensures the accuracy of the analytical results. In this work, a portable prototype of tip microextraction device (TMD) was designed and developed for on-site sample pretreatment. The assembly procedure of TMD is quite simple. Firstly, polymeric ionic liquid (PIL)-based adsorbent was in-situ prepared in a pipette tip. After that, the tip was connected with a syringe which was driven by a bidirectional motor. The flow rates in adsorption and desorption steps were controlled accurately by the motor. To evaluate the practicability of the developed device, the TMD was used to on-site sample preparation of waters and combined with high-performance liquid chromatography with diode array detection to measure trace estrogens in water samples. Under the most favorable conditions, the limits of detection (LODs, S/N = 3) for the target analytes were in the range of 4.9-22 ng/L, with good coefficients of determination. Confirmatory study well evidences that the extraction performance of TMD is comparable to that of the traditional laboratory solid-phase extraction process, but the proposed TMD is more simple and convenient. At the same time, the TMD avoids complicated sampling and transferring steps of large-volume water samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Development of gas-sampling device for 13N monitoring system

    International Nuclear Information System (INIS)

    Zhao Lihong; Gong Xueyu

    2003-01-01

    The 13 N monitoring system is used in the monitoring of the rate of leakage of the primary coolant circuit in nuclear power stations. The author introduces a gas-sampling device of the 13 Nmonitoring system. It is with a close-loop flow control system with intelligent control of Single Chip Micyoco (SCM), and has the ability to monitor and replace the filter paper automatically, to increase the automation of the device and stable operation in long time

  17. FISHprep: A Novel Integrated Device for Metaphase FISH Sample Preparation

    DEFF Research Database (Denmark)

    Shah, Pranjul Jaykumar; Vedarethinam, Indumathi; Kwasny, Dorota

    2011-01-01

    We present a novel integrated device for preparing metaphase chromosomes spread slides (FISHprep). The quality of cytogenetic analysis from patient samples greatly relies on the efficiency of sample pre-treatment and/or slide preparation. In cytogenetic slide preparation, cell cultures...... are routinely used to process samples (for culture, arrest and fixation of cells) and/or to expand limited amount of samples (in case of prenatal diagnostics). Arguably, this expansion and other sample pretreatments form the longest part of the entire diagnostic protocols spanning over 3–4 days. We present here...... with minimal handling for metaphase FISH slide preparation....

  18. Device to investigate samples by means of flameless atomic absorption measurement

    International Nuclear Information System (INIS)

    Sperling, K.R.

    1977-01-01

    An improvement on a device to investigate samples by means of flameless atomic absorption measurement is suggested in which one aims to produce a most complete possible atomic clond from the sample to be investigated within the sample space defined by the beam bundle, through which the measuring beam bundle is passed. According to the invention, the tubular sample space should be closed by an optically penetrable window on one side. (RW) [de

  19. Archive of Samples for Long-Term Preservation of RNA and Other Nucleic Acids

    Science.gov (United States)

    2016-05-15

    workflow can be developed for large scale blood collection , transport , and long-term archiving without the use of costly and unreliable cold chain...management, using commercially available biopreservation products. For the development of the automated workflow we have chosen Biomatrica’s commercially...This ambient workflow can be developed for large scale blood collection, transport and long-term nucleic acid archiving without the use of costly

  20. Development of an inventory/archive program for the retention, management, and disposition of tank characterization samples at the 222-S laboratory

    International Nuclear Information System (INIS)

    Seidel, C.M.

    1998-01-01

    The Hanford Tank Waste Remediation Systems (TWRS) Characterization Program is responsible for coordinating the sampling and analysis of the 177 large underground storage tanks at the Hanford site. The 222-S laboratory has been the primary laboratory for chemical analysis of this highly-radioactive material and has been accumulating these samples for many years. As part of the Fiscal Year 1998 laboratory work scope, the 222-S laboratory has performed a formal physical inventory of all tank characterization samples which are currently being stored. In addition, an updated inventory/archive program has been designed. This program defines sample storage, retention, consolidation, maintenance, and disposition activities which will ensure that the sample integrity is preserved to the greatest practical extent. In addition, the new program provides for continued availability of waste material in a form which will be useful for future bench-scale studies. Finally, when the samples have exceeded their useful lifetime, the program provides for sample disposition from,the laboratory in a controlled, safe and environmentally compliant manner. The 222-S laboratory maintains custody over samples of tank waste material which have been shipped to the laboratory for chemical analysis. The storage of these samples currently requires an entire hotcell, fully dedicated to sample archive storage, and is rapidly encroaching on additional hotcell space. As additional samples are received, they are beginning to limit the 222-S laboratory hotcell utility for other activities such as sample extrusion and subsampling. The 222-S laboratory tracks the number of sample containers and the mass of each sample through an internal database which has recently been verified and updated via a physical inventory

  1. A core handling device for the Mars Sample Return Mission

    Science.gov (United States)

    Gwynne, Owen

    1989-01-01

    A core handling device for use on Mars is being designed. To provide a context for the design study, it was assumed that a Mars Rover/Sample Return (MRSR) Mission would have the following characteristics: a year or more in length; visits by the rover to 50 or more sites; 100 or more meter-long cores being drilled by the rover; and the capability of returning about 5 kg of Mars regolith to Earth. These characteristics lead to the belief that in order to bring back a variegated set of samples that can address the range of scientific objetives for a MRSR mission to Mars there needs to be considerable analysis done on board the rover. Furthermore, the discrepancy between the amount of sample gathered and the amount to be returned suggests that there needs to be some method of choosing the optimal set of samples. This type of analysis will require pristine material-unaltered by the drilling process. Since the core drill thermally and mechanically alters the outer diameter (about 10 pct) of the core sample, this outer area cannot be used. The primary function of the core handling device is to extract subsamples from the core and to position these subsamples, and the core itself if needed, with respect to the various analytical instruments that can be used to perform these analyses.

  2. Development of a Novel Self-Enclosed Sample Preparation Device for DNA/RNA Isolation in Space

    Science.gov (United States)

    Zhang, Ye; Mehta, Satish K.; Pensinger, Stuart J.; Pickering, Karen D.

    2011-01-01

    Modern biology techniques present potentials for a wide range of molecular, cellular, and biochemistry applications in space, including detection of infectious pathogens and environmental contaminations, monitoring of drug-resistant microbial and dangerous mutations, identification of new phenotypes of microbial and new life species. However, one of the major technological blockades in enabling these technologies in space is a lack of devices for sample preparation in the space environment. To overcome such an obstacle, we constructed a prototype of a DNA/RNA isolation device based on our novel designs documented in the NASA New Technology Reporting System (MSC-24811-1/3-1). This device is self-enclosed and pipette free, purposely designed for use in the absence of gravity. Our design can also be modified easily for preparing samples in space for other applications, such as flowcytometry, immunostaining, cell separation, sample purification and separation according to its size and charges, sample chemical labeling, and sample purification. The prototype of our DNA/RNA isolation device was tested for efficiencies of DNA and RNA isolation from various cell types for PCR analysis. The purity and integrity of purified DNA and RNA were determined as well. Results showed that our developed DNA/RNA isolation device offers similar efficiency and quality in comparison to the samples prepared using the standard protocol in the laboratory.

  3. Biological samples positioning device for irradiations on a radial channel at the nuclear research reactor

    International Nuclear Information System (INIS)

    Rodriguez Gual, Maritza; Mas Milian, Felix; Deppman, Airton; Pinto Coelho, Paulo Rogerio

    2010-01-01

    For the demand of an experimental device for biological samples positioning system for irradiations on a radial channel at the nuclear research reactor in operation was constructed and started up a device for the place and remove of the biological samples from the irradiation channels without interrupting the operation of the reactor. The economical valuations are effected comparing with another type of device with the same functions. This work formed part of an international project between Cuba and Brazil that undertook the study of the induced damages by various types of ionizing radiation in DNA molecules. Was experimentally tested the proposed solution, which demonstrates the practical validity of the device. As a result of the work, the experimental device for biological samples irradiations are installed and operating in the radial beam hole No3(BH3) for more than five years at the IEA-R1 Brazilian research reactor according to the solicited requirements the device. The designed device increases considerably the type of studies can be conducted in this reactor. Its practical application in research taking place in that facility, in the field of radiobiology and dosimetry, and so on is immediate

  4. Methods and devices for hyperpolarising and melting NMR samples in a cryostat

    DEFF Research Database (Denmark)

    Ardenkjaer-Larsen, Jan Henrik; Axelsson, Oskar H. E.; Golman, Klaes Koppel

    2006-01-01

    The present invention relates to devices and method for melting solid polarised sample while retaining a high level of polarisation. In an embodiment of the present invention a sample is polarised in a sample-retaining cup 9 in a strong magnetic field in a polarising means 3a, 3b, 3c in a cryosta...

  5. Radiologic image communication and archive service: a secure, scalable, shared approach

    Science.gov (United States)

    Fellingham, Linda L.; Kohli, Jagdish C.

    1995-11-01

    The Radiologic Image Communication and Archive (RICA) service is designed to provide a shared archive for medical images to the widest possible audience of customers. Images are acquired from a number of different modalities, each available from many different vendors. Images are acquired digitally from those modalities which support direct digital output and by digitizing films for projection x-ray exams. The RICA Central Archive receives standard DICOM 3.0 messages and data streams from the medical imaging devices at customer institutions over the public telecommunication network. RICA represents a completely scalable resource. The user pays only for what he is using today with the full assurance that as the volume of image data that he wishes to send to the archive increases, the capacity will be there to accept it. To provide this seamless scalability imposes several requirements on the RICA architecture: (1) RICA must support the full array of transport services. (2) The Archive Interface must scale cost-effectively to support local networks that range from the very small (one x-ray digitizer in a medical clinic) to the very large and complex (a large hospital with several CTs, MRs, Nuclear medicine devices, ultrasound machines, CRs, and x-ray digitizers). (3) The Archive Server must scale cost-effectively to support rapidly increasing demands for service providing storage for and access to millions of patients and hundreds of millions of images. The architecture must support the incorporation of improved technology as it becomes available to maintain performance and remain cost-effective as demand rises.

  6. A HIGH FIDELITY SAMPLE OF COLD FRONT CLUSTERS FROM THE CHANDRA ARCHIVE

    International Nuclear Information System (INIS)

    Owers, Matt S.; Nulsen, Paul E. J.; Markevitch, Maxim; Couch, Warrick J.

    2009-01-01

    This paper presents a sample of 'cold front' clusters selected from the Chandra archive. The clusters are selected based purely on the existence of surface brightness edges in their Chandra images which are modeled as density jumps. A combination of the derived density and temperature jumps across the fronts is used to select nine robust examples of cold front clusters: 1ES0657 - 558, Abell 1201, Abell 1758N, MS1455.0+2232, Abell 2069, Abell 2142, Abell 2163, RXJ1720.1+2638, and Abell 3667. This sample is the subject of an ongoing study aimed at relating cold fronts to cluster merger activity, and understanding how the merging environment affects the cluster constituents. Here, temperature maps are presented along with the Chandra X-ray images. A dichotomy is found in the sample in that there exists a subsample of cold front clusters which are clearly mergers based on their X-ray morphologies, and a second subsample of clusters which harbor cold fronts, but have surprisingly relaxed X-ray morphologies, and minimal evidence for merger activity at other wavelengths. For this second subsample, the existence of a cold front provides the sole evidence for merger activity at X-ray wavelengths. We discuss how cold fronts can provide additional information which may be used to constrain merger histories, and also the possibility of using cold fronts to distinguish major and minor mergers.

  7. An unattended device for high-voltage sampling and passive measurement of thoron decay products

    Energy Technology Data Exchange (ETDEWEB)

    Gierl, Stefanie; Meisenberg, Oliver, E-mail: oliver.meisenberg@helmholtz-muenchen.de; Wielunski, Marek; Tschiersch, Jochen [Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstr. 1, 85764 Neuherberg (Germany); Haninger, Thomas [Helmholtz Zentrum München, German Research Center for Environmental Health, Auswertungsstelle für Strahlendosimeter, Otto-Hahn-Ring 6, 81739 München (Germany)

    2014-02-15

    An integrating measurement device for the concentration of airborne thoron decay products was designed and calibrated. It is suitable for unattended use over up to several months also in inhabited dwellings. The device consists of a hemispheric capacitor with a wire mesh as the outer electrode on ground potential and the sampling substrates as the inner electrode on +7.0 kV. Negatively charged and neutral thoron decay products are accelerated to and deposited on the sampling substrates. As sampling substrates, CR39 solid-state nuclear track detectors are used in order to record the alpha decay of the sampled decay products. Nuclide discrimination is achieved by covering the detectors with aluminum foil of different thickness, which are penetrated only by alpha particles with sufficient energy. Devices of this type were calibrated against working level monitors in a thoron experimental house. The sensitivity was measured as 9.2 tracks per Bq/m{sup 3} × d of thoron decay products. The devices were used over 8 weeks in several houses built of earthen material in southern Germany, where equilibrium equivalent concentrations of 1.4–9.9 Bq/m{sup 3} of thoron decay products were measured.

  8. Paper-based archiving of biological samples from fish for detecting betanodavirus.

    Science.gov (United States)

    Navaneeth Krishnan, A; Bhuvaneswari, T; Ezhil Praveena, P; Jithendran, K P

    2016-07-01

    This study was carried out to evaluate the efficiency of the Flinders Technology Associates (FTA(®)) card (Whatman(®)) as a sampling device and storage platform for RNA from betanodavirus-infected biological samples (viz., larvae, broodstock, cell culture supernatants and rearing seawater spiked with infected materials). The study showed that FTA cards can be used to detect betanodaviruses by reverse transcription-polymerase chain reaction (RT-PCR). The diagnostic efficiency of RT-PCR from all sample types on FTA cards decreased after 21 days of storage at 4 °C, although the virus could be detected up to 28 days by nested RT-PCR. The FTA card protocol thus provides a supplementary method for quick and easy collection of samples, preservation of RNA on a dry storage basis, and detection of betanodavirus-infected fish.

  9. Archival Descriptions from the National Archives Catalog

    Data.gov (United States)

    National Archives and Records Administration — Archival Descriptions from the National Archives Catalog data set provides archival descriptions of the permanent holdings of the federal government in the custody...

  10. Use of passive sampling devices to determine soil contaminant concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, K.A. [Clemson Univ., Pendleton, SC (United States)]|[Washington State Univ., Richland, WA (United States); Hooper, M.J. [Clemson Univ., Pendleton, SC (United States); Weisskopf, C.P. [Washington State Univ., Richland, WA (United States)

    1996-12-31

    The effective remediation of contaminated sites requires accurate identification of chemical distributions. A rapid sampling method using passive sampling devices (PSDs) can provide a thorough site assessment. We have been pursuing their application in terrestrial systems and have found that they increase the ease and speed of analysis, decrease solvent usage and overall cost, and minimize the transport of contaminated soils. Time and cost savings allow a higher sampling frequency than is generally the case using traditional methods. PSDs have been used in the field in soils of varying physical properties and have been successful in estimating soil concentrations ranging from 1 {mu}g/kg (parts per billion) to greater than 200 mg/kg (parts per million). They were also helpful in identifying hot spots within the sites. Passive sampling devices show extreme promise as an analytical tool to rapidly characterize contaminant distributions in soil. There are substantial time and cost savings in laboratory personnel and supplies. By selectively excluding common interferences that require sample cleanup, PSDs can be retrieved from the field and processed rapidly (one technician can process approximately 90 PSDs in an 8-h work day). The results of our studies indicate that PSDs can be used to accurately estimate soil contaminant concentrations and provide lower detection limits. Further, time and cost savings will allow a more thorough and detailed characterization of contaminant distributions. 13 refs., 4 figs., 2 tabs.

  11. Experience-Sampling Methodology with a Mobile Device in Fibromyalgia

    Directory of Open Access Journals (Sweden)

    Castilla Diana

    2012-01-01

    Full Text Available This work describes the usability studies conducted in the development of an experience-sampling methodology (ESM system running in a mobile device. The goal of the system is to improve the accuracy and ecology in gathering daily self-report data in individuals suffering a chronic pain condition, fibromyalgia. The usability studies showed that the developed software to conduct ESM with mobile devices (smartphones, cell phones can be successfully used by individuals with fibromyalgia of different ages and with low level of expertise in the use of information and communication technologies. 100% of users completed the tasks successfully, although some have completely illiterate. Also there seems to be a clear difference in the way of interaction obtained in the two studies carried out.

  12. Design of sample analysis device for iodine adsorption efficiency test in NPPs

    International Nuclear Information System (INIS)

    Ji Jinnan

    2015-01-01

    In nuclear power plants, iodine adsorption efficiency test is used to check the iodine adsorption efficiency of the iodine adsorber. The iodine adsorption efficiency can be calculated through the analysis of the test sample, and thus to determine if the performance of the adsorber meets the requirement on the equipment operation and emission. Considering the process of test and actual demand, in this paper, a special device for the analysis of this kind of test sample is designed. The application shows that the device is with convenient operation and high reliability and accurate calculation, and improves the experiment efficiency and reduces the experiment risk. (author)

  13. Detection of a Hobi-like virus in archival samples suggests circulation of this emerging pestivirus species in Europe prior to 2007

    Science.gov (United States)

    The first reported incidence of Hobi-like viruses in Europe dates to a 2010 outbreak of respiratory disease in cattle in Italy. In this study, a Hobi-like virus was detected in archival samples, collected in 2007 in Italy from a cattle herd displaying respiratory disease, during the validation of a...

  14. Rapid Surface Sampling and Archival Record (RSSAR) system. Final report, October 1995 - May 1997

    International Nuclear Information System (INIS)

    1998-01-01

    This report describes the results of Phase 2 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large task of concern to both government and industry. Because of the high cost of hazardous waste disposal, old, contaminated buildings cannot simply be demolished and scrapped. Contaminated and clean materials must be clearly identified and segregated so that the clean material can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. DOE has a number of sites requiring surface characterization. These sites are large, contain very heterogeneous patterns of contamination (requiring high sampling density), and will thus necessitate an enormous number of samples to be taken and analyzed. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmation process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible

  15. Rapid Surface Sampling and Archival Record (RSSAR) system. Final report, October 1995--May 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    This report describes the results of Phase 2 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large task of concern to both government and industry. Because of the high cost of hazardous waste disposal, old, contaminated buildings cannot simply be demolished and scrapped. Contaminated and clean materials must be clearly identified and segregated so that the clean material can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. DOE has a number of sites requiring surface characterization. These sites are large, contain very heterogeneous patterns of contamination (requiring high sampling density), and will thus necessitate an enormous number of samples to be taken and analyzed. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmation process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible.

  16. Mass-storage management for distributed image/video archives

    Science.gov (United States)

    Franchi, Santina; Guarda, Roberto; Prampolini, Franco

    1993-04-01

    The realization of image/video database requires a specific design for both database structures and mass storage management. This issue has addressed the project of the digital image/video database system that has been designed at IBM SEMEA Scientific & Technical Solution Center. Proper database structures have been defined to catalog image/video coding technique with the related parameters, and the description of image/video contents. User workstations and servers are distributed along a local area network. Image/video files are not managed directly by the DBMS server. Because of their wide size, they are stored outside the database on network devices. The database contains the pointers to the image/video files and the description of the storage devices. The system can use different kinds of storage media, organized in a hierarchical structure. Three levels of functions are available to manage the storage resources. The functions of the lower level provide media management. They allow it to catalog devices and to modify device status and device network location. The medium level manages image/video files on a physical basis. It manages file migration between high capacity media and low access time media. The functions of the upper level work on image/video file on a logical basis, as they archive, move and copy image/video data selected by user defined queries. These functions are used to support the implementation of a storage management strategy. The database information about characteristics of both storage devices and coding techniques are used by the third level functions to fit delivery/visualization requirements and to reduce archiving costs.

  17. Multiple double cross-section transmission electron microscope sample preparation of specific sub-10 nm diameter Si nanowire devices.

    Science.gov (United States)

    Gignac, Lynne M; Mittal, Surbhi; Bangsaruntip, Sarunya; Cohen, Guy M; Sleight, Jeffrey W

    2011-12-01

    The ability to prepare multiple cross-section transmission electron microscope (XTEM) samples from one XTEM sample of specific sub-10 nm features was demonstrated. Sub-10 nm diameter Si nanowire (NW) devices were initially cross-sectioned using a dual-beam focused ion beam system in a direction running parallel to the device channel. From this XTEM sample, both low- and high-resolution transmission electron microscope (TEM) images were obtained from six separate, specific site Si NW devices. The XTEM sample was then re-sectioned in four separate locations in a direction perpendicular to the device channel: 90° from the original XTEM sample direction. Three of the four XTEM samples were successfully sectioned in the gate region of the device. From these three samples, low- and high-resolution TEM images of the Si NW were taken and measurements of the NW diameters were obtained. This technique demonstrated the ability to obtain high-resolution TEM images in directions 90° from one another of multiple, specific sub-10 nm features that were spaced 1.1 μm apart.

  18. Novel Electrosorption-Enhanced Solid-Phase Microextraction Device for Ultrafast In Vivo Sampling of Ionized Pharmaceuticals in Fish.

    Science.gov (United States)

    Qiu, Junlang; Wang, Fuxin; Zhang, Tianlang; Chen, Le; Liu, Yuan; Zhu, Fang; Ouyang, Gangfeng

    2018-01-02

    Decreasing the tedious sample preparation duration is one of the most important concerns for the environmental analytical chemistry especially for in vivo experiments. However, due to the slow mass diffusion paths for most of the conventional methods, ultrafast in vivo sampling remains challenging. Herein, for the first time, we report an ultrafast in vivo solid-phase microextraction (SPME) device based on electrosorption enhancement and a novel custom-made CNT@PPY@pNE fiber for in vivo sampling of ionized acidic pharmaceuticals in fish. This sampling device exhibited an excellent robustness, reproducibility, matrix effect-resistant capacity, and quantitative ability. Importantly, the extraction kinetics of the targeted ionized pharmaceuticals were significantly accelerated using the device, which significantly improved the sensitivity of the SPME in vivo sampling method (limits of detection ranged from 0.12 ng·g -1 to 0.25 ng·g -1 ) and shorten the sampling time (only 1 min). The proposed approach was successfully applied to monitor the concentrations of ionized pharmaceuticals in living fish, which demonstrated that the device and fiber were suitable for ultrafast in vivo sampling and continuous monitoring. In addition, the bioconcentration factor (BCF) values of the pharmaceuticals were derived in tilapia (Oreochromis mossambicus) for the first time, based on the data of ultrafast in vivo sampling. Therefore, we developed and validated an effective and ultrafast SPME sampling device for in vivo sampling of ionized analytes in living organisms and this state-of-the-art method provides an alternative technique for future in vivo studies.

  19. Increasing Access to Archival Records in Library Online Public Access Catalogs.

    Science.gov (United States)

    Gilmore, Matthew B.

    1988-01-01

    Looks at the use of online public access catalogs, the utility of subject and call-number searching, and possible archival applications. The Wallace Archives at the Claremont Colleges is used as an example of the availability of bibliographic descriptions of multiformat archival materials through the library catalog. Sample records and searches…

  20. Archival approaches in the work of Paul Otlet

    Directory of Open Access Journals (Sweden)

    Leomar José Montilla Peña

    2015-02-01

    Full Text Available We present a bibliometric study of the Treaty of Documentation of Paul Otlet where the goal was to analyze approaches the archival area registered on it. For this study, used the descriptive words method and the associated words method. We applied a longitudinal statistical sampling for periods 1898 to 1933, because he published the first three scientists manuals the classical Archives. The results revealed that there is a total of 10 references related to the archives, the author being Otlet else mentioned, it has more citations and references on this area. The topics most frequently used by Otlet on archival science for discursive reasoning were: methods of organization and administrative documents. The analysis finds that archival approaches registered in the Treaty of Documentation have centrality and low density.

  1. Web archives

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2018-01-01

    This article deals with general web archives and the principles for selection of materials to be preserved. It opens with a brief overview of reasons why general web archives are needed. Section two and three present major, long termed web archive initiatives and discuss the purposes and possible...... values of web archives and asks how to meet unknown future needs, demands and concerns. Section four analyses three main principles in contemporary web archiving strategies, topic centric, domain centric and time-centric archiving strategies and section five discuss how to combine these to provide...... a broad and rich archive. Section six is concerned with inherent limitations and why web archives are always flawed. The last sections deal with the question how web archives may fit into the rapidly expanding, but fragmented landscape of digital repositories taking care of various parts...

  2. Construction of new data archive system in RIKEN RI beam factory

    International Nuclear Information System (INIS)

    Komiyama, M.; Fukunishi, N.; Uchiyama, A.

    2012-01-01

    RIKEN Radioactive Isotope Beam Factory (RIBF) is a cyclotron-based next-generation radioactive beam facility. RIBF uses two types of control systems; an experimental physics and industrial control system (EPICS)-based system and a group of several non-EPICS-based systems. For each control system there is a corresponding data archiving system in operation, and in order to unify these two data archives, since October 2009 we have been developing a new archiving system. This new data archive system, named RIBF Control Data Archive System (RIBFCAS), is required, at intervals between 1 - 60 s, to collect and store more than 3000 data generated by EPICS controlled devices through EPICS input/output controllers (IOCs). In addition, RIBFCAS must be able to combine the existing non-EPICS-based systems. To fulfill these requirements, a Java-based platform has been created, and client applications are based on Adobe AIR runtime. The RIBFCAS hardware system, therefore, consists of an application server, a database server and client-PCs. Presently, we have succeeded in stably acquiring approximately 3000 data from 22 IOCs every 10 s. Moreover, incorporation of the non-EPICS-based data archive system into RIBFCAS is now in progress. (authors)

  3. An automatic device for sample insertion and extraction to/from reactor irradiation facilities

    International Nuclear Information System (INIS)

    Alloni, L.; Venturelli, A.; Meloni, S.

    1990-01-01

    At the previous European Triga Users Conference in Vienna,a paper was given describing a new handling tool for irradiated samples at the L.E.N.A plant. This tool was the first part of an automatic device for the management of samples to be irradiated in the TRIGA MARK ii reactor and successively extracted and stored. So far sample insertion and extraction to/from irradiation facilities available on reactor top (central thimble,rotatory specimen rack and channel f),has been carried out manually by reactor and health-physics operators using the ''traditional'' fishing pole provided by General Atomic, thus exposing reactor personnel to ''unjustified'' radiation doses. The present paper describes the design and the operation of a new device, a ''robot''type machine,which, remotely operated, takes care of sample insertion into the different irradiation facilities,sample extraction after irradiation and connection to the storage pits already described. The extraction of irradiated sample does not require the presence of reactor personnel on the reactor top and,therefore,radiation doses are strongly reduced. All work from design to construction has been carried out by the personnel of the electronic group of the L.E.N.A plant. (orig.)

  4. Device for the analysis of feedwater and condensation samples from power plants

    International Nuclear Information System (INIS)

    Mostofin, A.A.; Sorokina, N.S.

    1978-01-01

    An improved version of a device for automatic measurement of the salt and NH 3 contents of feedwater and condensate samples from nuclear power plants is described. Only one sample is required for determining both values. The invention proposes on the one hand to change the dimensions of a throttle opening and on the other to install a second measuring instrument (conductivity measuring instrument). (UWI) [de

  5. A flexible image archiving system using a personal computer and optical disk

    International Nuclear Information System (INIS)

    Parkin, A.; Norwood, H.; Hall, A.J.

    1989-01-01

    The authors describe the application of a personal computer and optical disk as an image archiving device, which brings the advantages of large capacity, low cost and savings on storage space. (author)

  6. Sampling technologies and air pollution control devices for gaseous and particulate arsenic: a review

    International Nuclear Information System (INIS)

    Helsen, Lieve

    2005-01-01

    Direct measurement of arsenic release requires a good sampling and analysis procedure in order to capture and detect the total amount of metals emitted. The literature is extensively reviewed in order to evaluate the efficiency of full field-scale and laboratory scale techniques for capturing particulate and gaseous emissions of arsenic from the thermo-chemical treatment of different sources of arsenic. Furthermore, trace arsenic concentrations in ambient air, national standard sampling methods and arsenic analysis methods are considered. Besides sampling techniques, the use of sorbents is also reviewed with respect to both approaches (1) to prevent the metals from exiting with the flue gas and (2) to react or combine with the metals in order to be collected in air pollution control systems. The most important conclusion is that submicron arsenic fumes are difficult to control in conventional air pollution control devices. Complete capture of the arsenic species requires a combination of particle control and vapour control devices. - Submicron arsenic fumes are difficult to control in conventional air pollution control devices

  7. DICOM-compliant PACS with CD-based image archival

    Science.gov (United States)

    Cox, Robert D.; Henri, Christopher J.; Rubin, Richard K.; Bret, Patrice M.

    1998-07-01

    This paper describes the design and implementation of a low- cost PACS conforming to the DICOM 3.0 standard. The goal was to provide an efficient image archival and management solution on a heterogeneous hospital network as a basis for filmless radiology. The system follows a distributed, client/server model and was implemented at a fraction of the cost of a commercial PACS. It provides reliable archiving on recordable CD and allows access to digital images throughout the hospital and on the Internet. Dedicated servers have been designed for short-term storage, CD-based archival, data retrieval and remote data access or teleradiology. The short-term storage devices provide DICOM storage and query/retrieve services to scanners and workstations and approximately twelve weeks of 'on-line' image data. The CD-based archival and data retrieval processes are fully automated with the exception of CD loading and unloading. The system employs lossless compression on both short- and long-term storage devices. All servers communicate via the DICOM protocol in conjunction with both local and 'master' SQL-patient databases. Records are transferred from the local to the master database independently, ensuring that storage devices will still function if the master database server cannot be reached. The system features rules-based work-flow management and WWW servers to provide multi-platform remote data access. The WWW server system is distributed on the storage, retrieval and teleradiology servers allowing viewing of locally stored image data directly in a WWW browser without the need for data transfer to a central WWW server. An independent system monitors disk usage, processes, network and CPU load on each server and reports errors to the image management team via email. The PACS was implemented using a combination of off-the-shelf hardware, freely available software and applications developed in-house. The system has enabled filmless operation in CT, MR and ultrasound within

  8. A Simple Device for Lens-to-Sample Distance Adjustment in Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Cortez, Juliana; Farias Filho, Benedito B; Fontes, Laiane M; Pasquini, Celio; Raimundo, Ivo M; Pimentel, Maria Fernanda; de Souza Lins Borba, Flávia

    2017-04-01

    A simple device based on two commercial laser pointers is described to assist in the analysis of samples that present uneven surfaces and/or irregular shapes using laser-induced breakdown spectroscopy (LIBS). The device allows for easy positioning of the sample surface at a reproducible distance from the focusing lens that conveys the laser pulse to generate the micro-plasma in a LIBS system, with reproducibility better than ±0.2 mm. In this way, fluctuations in the fluence (J cm -2 ) are minimized and the LIBS analytical signals can be obtained with a better precision even when samples with irregular surfaces are probed.

  9. Short communication: Influence of the sampling device on somatic cell count variation in cow milk samples (by official recording)

    International Nuclear Information System (INIS)

    Fouz, R.; Vilar, M.J.; Yus, E.; Sanjuán, M.L.; Diéguez, F.J.

    2016-01-01

    The objective of this study was to investigate the variability in cow´s milk somatic cell counts (SCC) depending on the type of milk meter used by dairy farms for official milk recording. The study was performed in 2011 and 2012 in the major cattle area of Spain. In total, 137,846 lactations of Holstein-Friesian cows were analysed at 1,912 farms. A generalised least squares regression model was used for data analysis. The model showed that the milk meter had a substantial effect on the SCC for individual milk samples obtained for official milk recording. The results suggested an overestimation of the SCC in milk samples from farms that had electronic devices in comparison with farms that used portable devices and underestimation when volumetric meters are used. A weak positive correlation was observed between the SCC and the percentage of fat in individual milk samples. The results underline the importance of considering this variable when using SCC data from milk recording in the dairy herd improvement program or in quality milk programs. (Author)

  10. Short communication: Influence of the sampling device on somatic cell count variation in cow milk samples (by official recording)

    Energy Technology Data Exchange (ETDEWEB)

    Fouz, R.; Vilar, M.J.; Yus, E.; Sanjuán, M.L.; Diéguez, F.J.

    2016-11-01

    The objective of this study was to investigate the variability in cow´s milk somatic cell counts (SCC) depending on the type of milk meter used by dairy farms for official milk recording. The study was performed in 2011 and 2012 in the major cattle area of Spain. In total, 137,846 lactations of Holstein-Friesian cows were analysed at 1,912 farms. A generalised least squares regression model was used for data analysis. The model showed that the milk meter had a substantial effect on the SCC for individual milk samples obtained for official milk recording. The results suggested an overestimation of the SCC in milk samples from farms that had electronic devices in comparison with farms that used portable devices and underestimation when volumetric meters are used. A weak positive correlation was observed between the SCC and the percentage of fat in individual milk samples. The results underline the importance of considering this variable when using SCC data from milk recording in the dairy herd improvement program or in quality milk programs. (Author)

  11. Genetic Sample Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database archives genetic tissue samples from marine mammals collected primarily from the U.S. east coast. The collection includes samples from field programs,...

  12. Sample Curation in Support of the OSIRIS-REx Asteroid Sample Return Mission

    Science.gov (United States)

    Righter, Kevin; Nakamura-Messenger, Keiko

    2017-01-01

    The OSIRIS-REx asteroid sample return mission launched to asteroid Bennu Sept. 8, 2016. The spacecraft will arrive at Bennu in late 2019, orbit and map the asteroid, and perform a touch and go (TAG) sampling maneuver in July 2020. After sample is stowed and confirmed the spacecraft will return to Earth, and the sample return capsule (SRC) will land in Utah in September 2023. Samples will be recovered from Utah [2] and then transported and stored in a new sample cleanroom at NASA Johnson Space Center in Houston [3]. The materials curated for the mission are described here. a) Materials Archive and Witness Plate Collection: The SRC and TAGSAM were built between March 2014 and Summer of 2015, and instruments (OTES,OVIRS, OLA, OCAMS, REXIS) were integrated from Summer 2015 until May 2016. A total of 395 items were received for the materials archive at NASA-JSC, with archiving finishing 30 days after launch (with the final archived items being related to launch operations)[4]. The materials fall into several general categories including metals (stainless steel, aluminum, titanium alloys, brass and BeCu alloy), epoxies, paints, polymers, lubricants, non-volatile-residue samples (NVR), sapphire, and various miscellaneous materials. All through the ATLO process (from March 2015 until late August 2016) contamination knowledge witness plates (Si wafer and Al foil) were deployed in the various cleanrooms in Denver and KSC to provide an additional record of particle counts and volatiles that is archived for current and future scientific studies. These plates were deployed in roughly monthly increments with each unit containing 4 Si wafers and 4 Al foils. We archived 128 individual witness plates (64 Si wafers and 64 Al foils); one of each witness plate (Si and Al) was analyzed immediately by the science team after archiving, while the remaining 3 of each are archived indefinitely. Information about each material archived is stored in an extensive database at NASA-JSC, and key

  13. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  14. AFSC/RACE/GAP/Nichol: Archival tag depth and temperature data from Atka mackerel

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Atka mackerel Pleurogrammus monopterygius were captured and tagged with depth and temperature recording devices (archival tags) on 23 July 2000 in Seguam Pass,...

  15. The GIK-Archive of sediment core radiographs with documentation

    Science.gov (United States)

    Grobe, Hannes; Winn, Kyaw; Werner, Friedrich; Driemel, Amelie; Schumacher, Stefanie; Sieger, Rainer

    2017-12-01

    The GIK-Archive of radiographs is a collection of X-ray negative and photographic images of sediment cores based on exposures taken since the early 1960s. During four decades of marine geological work at the University of Kiel, Germany, several thousand hours of sampling, careful preparation and X-raying were spent on producing a unique archive of sediment radiographs from several parts of the World Ocean. The archive consists of more than 18 500 exposures on chemical film that were digitized, geo-referenced, supplemented with metadata and archived in the data library PANGAEA®. With this publication, the images have become available open-access for use by the scientific community at https://doi.org/10.1594/PANGAEA.854841.

  16. Data archiving and serving system implementation in CLEP's GRAS Core System

    Science.gov (United States)

    Zuo, Wei; Zeng, Xingguo; Zhang, Zhoubin; Geng, Liang; Li, Chunlai

    2017-04-01

    The Ground Research & Applications System(GRAS) is one of the five systems of China's Lunar Exploration Project(CLEP), it is responsible for data acquisition, processing, management and application, and it is also the operation control center during satellite in-orbit and payload operation management. Chang'E-1, Chang'E-2 and Chang'E-3 have collected abundant lunar exploration data. The aim of this work is to present the implementation of data archiving and Serving in CLEP's GRAS Core System software. This first approach provides a client side API and server side software allowing the creation of a simplified version of CLEPDB data archiving software, and implements all required elements to complete data archiving flow from data acquisition until its persistent storage technology. The client side includes all necessary components that run on devices that acquire or produce data, distributing and streaming to configure remote archiving servers. The server side comprises an archiving service that stores into PDS files all received data. The archiving solution aims at storing data coming for the Data Acquisition Subsystem, the Operation Management Subsystem, the Data Preprocessing Subsystem and the Scientific Application & Research Subsystem. The serving solution aims at serving data for the various business systems, scientific researchers and public users. The data-driven and component clustering methods was adopted in this system, the former is used to solve real-time data archiving and data persistence services; the latter is used to keep the continuous supporting ability of archive and service to new data from Chang'E Mission. Meanwhile, it can save software development cost as well.

  17. Optimisation and validation of methods to assess single nucleotide polymorphisms (SNPs) in archival histological material

    DEFF Research Database (Denmark)

    Andreassen, C N; Sørensen, Flemming Brandt; Overgaard

    2004-01-01

    only archival specimens are available. This study was conducted to validate protocols optimised for assessment of SNPs based on paraffin embedded, formalin fixed tissue samples.PATIENTS AND METHODS: In 137 breast cancer patients, three TGFB1 SNPs were assessed based on archival histological specimens...... precipitation).RESULTS: Assessment of SNPs based on archival histological material is encumbered by a number of obstacles and pitfalls. However, these can be widely overcome by careful optimisation of the methods used for sample selection, DNA extraction and PCR. Within 130 samples that fulfil the criteria...

  18. Paper-Based Analytical Device for Zinc Ion Quantification in Water Samples with Power-Free Analyte Concentration

    Directory of Open Access Journals (Sweden)

    Hiroko Kudo

    2017-04-01

    Full Text Available Insufficient sensitivity is a general issue of colorimetric paper-based analytical devices (PADs for trace analyte detection, such as metal ions, in environmental water. This paper demonstrates the colorimetric detection of zinc ions (Zn2+ on a paper-based analytical device with an integrated analyte concentration system. Concentration of Zn2+ ions from an enlarged sample volume (1 mL has been achieved with the aid of a colorimetric Zn2+ indicator (Zincon electrostatically immobilized onto a filter paper substrate in combination with highly water-absorbent materials. Analyte concentration as well as sample pretreatment, including pH adjustment and interferent masking, has been elaborated. The resulting device enables colorimetric quantification of Zn2+ in environmental water samples (tap water, river water from a single sample application. The achieved detection limit of 0.53 μM is a significant improvement over that of a commercial colorimetric Zn2+ test paper (9.7 μM, demonstrating the efficiency of the developed analyte concentration system not requiring any equipment.

  19. The Materiality of Method: The Case of the Mass Observation Archive

    OpenAIRE

    Liz Moor; Emma Uprichard

    2014-01-01

    The Mass Observation Archive presents numerous methodological issues for social researchers. The data are idiosyncratic, difficult to analyze, and the sample design is nonsystematic. Such issues seriously challenge conventional social research protocols. This article highlights a further characteristic of the archive: its unwieldy materiality. Focusing on the sensory experiences of the archive and its particular type of data, the article shows how the experience of getting ‘dirty with dataâ...

  20. Main - RPSD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ... as rice. Data file File name: rpsd_main_sjis.zip File URL: ftp://ftp.biosciencedbc.jp/archive/rpsd/LATEST/r.../ftp.biosciencedbc.jp/archive/rpsd/LATEST/rpsd_main_utf8.zip File size: 120 KB Simple search URL http://togo...nse Update History of This Database Site Policy | Contact Us Main - RPSD | LSDB Archive ...

  1. Protocol - RPD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...e version) File URL: ftp://ftp.biosciencedbc.jp/archive/rpd/LATEST/rpd_protocol_jp.zip File size: 535 KB Fil...e name: rpd_protocol_en.zip (English version) File URL: ftp://ftp.biosciencedbc.jp/archiv...tabase Database Description Download License Update History of This Database Site Policy | Contact Us Protocol - RPD | LSDB Archive ...

  2. Use of passive sampling devices for monitoring and compliance checking of POP concentrations in water

    NARCIS (Netherlands)

    Lohmann, R.; Booij, K.; Smedes, F.; Vrana, B.

    2012-01-01

    The state of the art of passive water sampling of (nonpolar) organic contaminants is presented. Its suitability for regulatory monitoring is discussed, with an emphasis on the information yielded by passive sampling devices (PSDs), their relevance and associated uncertainties. Almost all persistent

  3. Archive & Data Management Activities for ISRO Science Archives

    Science.gov (United States)

    Thakkar, Navita; Moorthi, Manthira; Gopala Krishna, Barla; Prashar, Ajay; Srinivasan, T. P.

    2012-07-01

    ISRO has kept a step ahead by extending remote sensing missions to planetary and astronomical exploration. It has started with Chandrayaan-1 and successfully completed the moon imaging during its life time in the orbit. Now, in future ISRO is planning to launch Chandrayaan-2 (next moon mission), Mars Mission and Astronomical mission ASTROSAT. All these missions are characterized by the need to receive process, archive and disseminate the acquired science data to the user community for analysis and scientific use. All these science missions will last for a few months to a few years but the data received are required to be archived, interoperable and requires a seamless access to the user community for the future. ISRO has laid out definite plans to archive these data sets in specified standards and develop relevant access tools to be able to serve the user community. To achieve this goal, a Data Center is set up at Bangalore called Indian Space Science Data Center (ISSDC). This is the custodian of all the data sets of the current and future science missions of ISRO . Chandrayaan-1 is the first among the planetary missions launched/to be launched by ISRO and we had taken the challenge and developed a system for data archival and dissemination of the payload data received. For Chandrayaan-1 the data collected from all the instruments are processed and is archived in the archive layer in the Planetary Data System (PDS 3.0) standards, through the automated pipeline. But the dataset once stored is of no use unless it is made public, which requires a Web-based dissemination system that can be accessible to all the planetary scientists/data users working in this field. Towards this, a Web- based Browse and Dissemination system has been developed, wherein users can register and search for their area of Interest and view the data archived for TMC & HYSI with relevant Browse chips and Metadata of the data. Users can also order the data and get it on their desktop in the PDS

  4. The Self-Organized Archive: SPASE, PDS and Archive Cooperatives

    Science.gov (United States)

    King, T. A.; Hughes, J. S.; Roberts, D. A.; Walker, R. J.; Joy, S. P.

    2005-05-01

    Information systems with high quality metadata enable uses and services which often go beyond the original purpose. There are two types of metadata: annotations which are items that comment on or describe the content of a resource and identification attributes which describe the external properties of the resource itself. For example, annotations may indicate which columns are present in a table of data, whereas an identification attribute would indicate source of the table, such as the observatory, instrument, organization, and data type. When the identification attributes are collected and used as the basis of a search engine, a user can constrain on an attribute, the archive can then self-organize around the constraint, presenting the user with a particular view of the archive. In an archive cooperative where each participating data system or archive may have its own metadata standards, providing a multi-system search engine requires that individual archive metadata be mapped to a broad based standard. To explore how cooperative archives can form a larger self-organized archive we will show how the Space Physics Archive Search and Extract (SPASE) data model will allow different systems to create a cooperative and will use Planetary Data System (PDS) plus existing space physics activities as a demonstration.

  5. VAPOR SAMPLING DEVICE FOR INTERFACE WITH MICROTOX ASSAY FOR SCREENING TOXIC INDUSTRIAL CHEMICALS

    Science.gov (United States)

    A time-integrated sampling system interfaced with a toxicity-based assay is reported for monitoring volatile toxic industrial chemicals (TICs). Semipermeable membrane devices (SPMDs) using dimethyl sulfoxide (DMSO) as the fill solvent accumulated each of 17 TICs from the vapor...

  6. Genetic Sample Inventory - NRDA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database archives genetic tissue samples from marine mammals collected in the North-Central Gulf of Mexico from 2010-2015. The collection includes samples from...

  7. A biological survey on the Ottoman Archive papers and determination of the D10 value

    Science.gov (United States)

    Kantoğlu, Ömer; Ergun, Ece; Ozmen, Dilan; Halkman, Hilal B. D.

    2018-03-01

    The Ottoman Archives have one of the richest archive collections in the world. However, not all the archived documents are well preserved and some undergo biodeterioration. Therefore, a rapid and promising treatment method is necessary to preserve the collection for following generations as heritage. Radiation presents as an alternative for the treatment of archival materials for this purpose. In this study, we conducted a survey to determine the contamination species and the D10 values of the samples obtained from the shelves of the Ottoman Archives. The samples also included several insect pests collected at using a pheromone trap placed in the archive storage room. With the exception of few localized problems, no active pest presence was observed. The D10 values of mold contamination and reference mold (A. niger) were found to be 1.0 and 0.68 kGy, respectively. Based on these results, it can be concluded that an absorbed dose of 6 kGy is required to remove the contamination from the materials stored in the Ottoman Archives.

  8. 14CO2 analysis of soil gas: Evaluation of sample size limits and sampling devices

    Science.gov (United States)

    Wotte, Anja; Wischhöfer, Philipp; Wacker, Lukas; Rethemeyer, Janet

    2017-12-01

    Radiocarbon (14C) analysis of CO2 respired from soils or sediments is a valuable tool to identify different carbon sources. The collection and processing of the CO2, however, is challenging and prone to contamination. We thus continuously improve our handling procedures and present a refined method for the collection of even small amounts of CO2 in molecular sieve cartridges (MSCs) for accelerator mass spectrometry 14C analysis. Using a modified vacuum rig and an improved desorption procedure, we were able to increase the CO2 recovery from the MSC (95%) as well as the sample throughput compared to our previous study. By processing series of different sample size, we show that our MSCs can be used for CO2 samples of as small as 50 μg C. The contamination by exogenous carbon determined in these laboratory tests, was less than 2.0 μg C from fossil and less than 3.0 μg C from modern sources. Additionally, we tested two sampling devices for the collection of CO2 samples released from soils or sediments, including a respiration chamber and a depth sampler, which are connected to the MSC. We obtained a very promising, low process blank for the entire CO2 sampling and purification procedure of ∼0.004 F14C (equal to 44,000 yrs BP) and ∼0.003 F14C (equal to 47,000 yrs BP). In contrast to previous studies, we observed no isotopic fractionation towards lighter δ13C values during the passive sampling with the depth samplers.

  9. Fabrication and Characterization of a Microfluidic Device to Ultrapurify Blood Samples

    KAUST Repository

    Tallerico, Marco

    2015-05-04

    The improvement of blood cell sorting techniques in recent years have attracted the attention of many researchers due to the possible benefits that these methods can lead in biology, regenerative medicine, materials science and therapeutic area. In this work a cell sorting technique based on filtration is described. The separation occurs by means of a microfluidic device, suitably designed, manufactured and tested, that is connected to an external experimental set-up. The fabrication process can be divided in two parts: at first it is described the manufacturing process of a filtering membrane, with holes of specific size that allow the passage of only certain cell types. Following the microfluidic device is fabricated through the mechanical micromilling. The membrane and the microdevice are suitably bonded and tested by means of an external connection with syringe pumps that inject blood samples at specific flow rates. The device is designed to separate blood cells and tumor cells only by using differences in size and shape. In particular during the first experiments red blood cells and platelets are sorted from white blood cells; in the other experiments red blood cells and platelets are separated from white blood cells and tumor cells. The microdevice has proven to be very efficient, in fact a capture efficiency of 99% is achieved. For this reason it could be used in identification and isolation of circulating tumor cells, a very rare cancer cell type whose presence in the bloodstream could be symptom of future solid tumor formation. The various experiments have also demonstrated that tumor cells survive even after the separation treatment, and then the suffered stress during the sorting process does not harm the biological sample.

  10. Images - RPSD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ta file File name: rpsd_images.zip File URL: ftp://ftp.biosciencedbc.jp/archive/rpsd/LATEST/rpsd_images.zip ... History of This Database Site Policy | Contact Us Images - RPSD | LSDB Archive ...

  11. Main - PLACE | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ilable. Data file File name: place_main.zip File URL: ftp://ftp.biosciencedbc.jp/archive/place/LATEST/place_...se Update History of This Database Site Policy | Contact Us Main - PLACE | LSDB Archive ...

  12. Calorimeter Process Variable Archiving

    International Nuclear Information System (INIS)

    Huffman, David

    2002-01-01

    These steps were taken to maintain weekly archives: (1) Friday morning you stop the archiver and wait for it to finish writing data (the lock file will be removed from the directory); (2) move the current archive information to a PC via FTP; (3) remove all previous archive information in the previous directory; (4) move the current archive into the previous directory; (5) start a new archive; (6) burn a CDROM of the archive; and (7) copy the current archive to a specific directory. There are 2 ways to check if the Calorimeter Archiver is running, either through the WEB based front end or directly from a command line. Once the archiver is running it can be monitored from a WEB page. This only works with a browser launched from the online machine running the archiver. Each time the browser is reloaded there should be an update reported in the last write check field. You might have to wait a few minutes to see the update. Calorimetry currently takes readings every (300 sec.) 5 minutes. The second method to verify the archiver is running is to issue a command from a Linux cluster machine.

  13. Analyzing Archival Intelligence: A Collaboration Between Library Instruction and Archives

    Directory of Open Access Journals (Sweden)

    Merinda Kaye Hensley

    2014-07-01

    Full Text Available Although recent archival scholarship promotes the use of primary sources for developing students’ analytical research skills, few studies focus on standards or protocols for teaching or assessing archival instruction. Librarians have designed and tested standards and learning assessment strategies for library instruction and archivists would do well to collaborate with and learn from their experience. This study examines lessons learned from one such collaboration between an instructional services librarian and archivist to evaluate and enhance archival instruction in the University Archives’ Student Life and Culture Archival Program (SLC Archives at the University of Illinois at Urbana-Champaign Library. Based on evaluative data from a student survey and in-depth interviews, the authors offer strategies for meeting and exceeding learning outcomes for archival intelligence more successfully.

  14. Test suite for the archiver of a SCADA system

    CERN Document Server

    Voitier, Axel

    2009-01-01

    Topic: The group responsible for providing the main control system applications for all machines at CERN has to validate that every piece of the control systems used will be reliable and fully functional when the LHC and its experiments will do collisions of particles. CERN use PVSS from ETM/Siemens for the SCADA part of its control systems. This software has a component dedicated to archive into a centralised Oracle database values and commands of tenth of thousands hardware devices. This component, named RDB, has to be tested and validated in terms of functionality and performance. The need is high for that because archiving is a critical part of the control systems. In case of an incident on one of the machine, it will be unacceptable to not benefit of archiving the machine context at this moment just because of a bug in RDB. Bugs have to be spotted and reported to ETM. Results: The proposed solution is an extensible automatic tester able to evaluate currently around 160 cases of potential bugs. Since the ...

  15. Coupling meteorology, metal concentrations, and Pb isotopes for source attribution in archived precipitation samples.

    Science.gov (United States)

    Graney, Joseph R; Landis, Matthew S

    2013-03-15

    A technique that couples lead (Pb) isotopes and multi-element concentrations with meteorological analysis was used to assess source contributions to precipitation samples at the Bondville, Illinois USA National Trends Network (NTN) site. Precipitation samples collected over a 16month period (July 1994-October 1995) at Bondville were parsed into six unique meteorological flow regimes using a minimum variance clustering technique on back trajectory endpoints. Pb isotope ratios and multi-element concentrations were measured using high resolution inductively coupled plasma-sector field mass spectrometry (ICP-SFMS) on the archived precipitation samples. Bondville is located in central Illinois, ~250km downwind from smelters in southeast Missouri. The Mississippi Valley Type ore deposits in Missouri provided a unique multi-element and Pb isotope fingerprint for smelter emissions which could be contrasted to industrial emissions from the Chicago and Indianapolis urban areas (~125km north and east, of Bondville respectively) and regional emissions from electric utility facilities. Differences in Pb isotopes and element concentrations in precipitation corresponded to flow regime. Industrial sources from urban areas, and thorogenic Pb from coal use, could be differentiated from smelter emissions from Missouri by coupling Pb isotopes with variations in element ratios and relative mass factors. Using a three endmember mixing model based on Pb isotope ratio differences, industrial processes in urban airsheds contributed 56±19%, smelters in southeast Missouri 26±13%, and coal combustion 18±7%, of the Pb in precipitation collected in Bondville in the mid-1990s. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Archives and the computer

    CERN Document Server

    Cook, Michael Garnet

    1986-01-01

    Archives and the Computer deals with the use of the computer and its systems and programs in archiving data and other related materials. The book covers topics such as the scope of automated systems in archives; systems for records management, archival description, and retrieval; and machine-readable archives. The selection also features examples of archives from different institutions such as the University of Liverpool, Berkshire County Record Office, and the National Maritime Museum.The text is recommended for archivists who would like to know more about the use of computers in archiving of

  17. Archives and the computer

    CERN Document Server

    Cook, Michael Garnet

    1980-01-01

    Archives and the Computer deals with the use of the computer and its systems and programs in archiving data and other related materials. The book covers topics such as the scope of automated systems in archives; systems for records management, archival description, and retrieval; and machine-readable archives. The book also features examples of systems for records management from different institutions such as theTyne and Wear Archive Department, Dyfed Record Office, and the University of Liverpool. Included in the last part are appendices. Appendix A is a directory of archival systems, Appen

  18. Main - KOME | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ntents List of datasets Data file File name: kome_main.zip File URL: ftp://ftp.biosciencedbc.jp/archive/kome...ase Database Description Download License Update History of This Database Site Policy | Contact Us Main - KOME | LSDB Archive ...

  19. Reference - PLACE | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ailable. Data file File name: place_reference.zip File URL: ftp://ftp.biosciencedbc.jp/archive/place/LATEST/...ber About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Reference - PLACE | LSDB Archive ...

  20. Alignment - SAHG | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...e URL: ftp://ftp.biosciencedbc.jp/archive/sahg/LATEST/sahg_alignment.zip File size: 12.0 MB Simple search UR...s Database Database Description Download License Update History of This Database Site Policy | Contact Us Alignment - SAHG | LSDB Archive ...

  1. Exon - ASTRA | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ontents Exons in variants Data file File name: astra_exon.zip File URL: ftp://ftp.biosciencedbc.jp/archive/a... About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Exon - ASTRA | LSDB Archive ...

  2. Access to Archives at the National Archives of Namibia ...

    African Journals Online (AJOL)

    This article is based on findings of a study of the National Archives of Namibia conducted in 2015. The study investigated the terms and conditions that guide access at the National Archives of Namibia. The study also investigated how the National Archives of Namibia has conformed to the ICA Code of Ethics and The ...

  3. Epilepsy Forewarning Using A Hand-Held Device

    Energy Technology Data Exchange (ETDEWEB)

    Hively, LM

    2005-02-21

    Over the last decade, ORNL has developed and patented a novel approach for forewarning of a large variety of machine and biomedical events. The present implementation uses desktop computers to analyze archival data. This report describes the next logical step in this effort, namely use of a hand-held device for the analysis.

  4. Electronic module for control of sample feeding device of spectrometers of X-ray fluorescent analysis of CRV type

    International Nuclear Information System (INIS)

    Petrov, V.A.; Fursov, A.V.

    2002-01-01

    The scheme of electronic module for sample feeding device control for the CRV type X-ray fluorescence analysis spectrometers is considered. This module provides realization of next functions: sample change operations and installation in starting position; signaling and defense at emergency cases; indication of any sample amount in the spectrometer chamber; testing function at tuning and testing of modules. All these principal functions are entrusted with microcontroller. Programming of the microcontroller is putting into effect by algorithm of the whole sample feeding device. In the capacity of microcontroller the single crystalline processor PICI16C54 and stepping motor of NV-306-V2202 model have been used

  5. Locus - ASTRA | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...URL: ftp://ftp.biosciencedbc.jp/archive/astra/LATEST/astra_locus.zip File size: 887 KB Simple search URL htt...icing type (ex. cassette) About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Locus - ASTRA | LSDB Archive ...

  6. Sample (S) - Metabolonote | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available the company name and catalog id. Preparation Growing methods, conditions, particular processing, sampling... portions, sampling methods, and preparation methods for reagents Comment Comment An

  7. Protein - TP Atlas | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...p_atlas_protein.zip File URL: ftp://ftp.biosciencedbc.jp/archive/tp_atlas/LATEST/...story of This Database Site Policy | Contact Us Protein - TP Atlas | LSDB Archive ...

  8. HyperArchiver: an EPICS archiver prototype based on Hypertable

    International Nuclear Information System (INIS)

    Giacchini, M.; Giovannini, L.; Montis, M.; Bassato, G.; Vasquez, J.A.; Prete, G.; Andrighetto, A.; Petkus, R.; Lange, R.; Kasemir, K.; Del Campo, M.; Jugo, J.

    2012-01-01

    This work started in the context of NSLS2 project at Brookhaven National Laboratory. The NSLS2 control system foresees a very high number of PV variables and has strict requirements in terms of archiving/retrieving rate: our goal was to store 10 K PV/sec and retrieve 4 K PV/sec for a group of 4 signals. The HyperArchiver is an EPICS Archiver implementation engined by Hypertable, an open source database whose internal architecture is derived from Google's Big Table. We discuss the performance of HyperArchiver and present the results of some comparative tests. (authors)

  9. Real time acquisition, processing, and archiving of Doublet III diagram data employing table driven software

    International Nuclear Information System (INIS)

    Glad, A.; Henline, P.; Gross, L.; McHarg, B.

    1979-11-01

    This paper describes the diagnostic data acquisition, processing and archiving computer system for the Doublet III fusion research device. This paper's emphasis is mainly on the software, but provides a description of the hardware configuration

  10. Installation and sampling of vadose zone monitoring devices

    International Nuclear Information System (INIS)

    Bergeron, S.M.; Strickland, D.J.; Pearson, R.

    1987-10-01

    A vadose zone monitoring system was installed in a sanitary landfill near the Y-12 facility on the Department of Energy's Oak Ridge, Tennessee Reservation. The work was completed as part of the LLWDDD program to develop, design, and demonstrate new low level radioactive waste disposal monitoring methods. The objective of the project was to evaluate the performance of three types of vadose zone samplers within a similar hydrogeologic environment for use as early detection monitoring devices. The three different types of samplers included the Soil Moisture Equipment Corporation Pressure-Vacuum samplers (Models 1920 and 1940), and the BAT Piezometer (Model MK II) manufactured by BAT Envitech, Inc. All three samplers are designed to remove soil moisture from the vadose (unsaturated) zone. Five clusters of three holes each were drilled to maximum depths of 45 ft around part of the periphery of the landfill. Three samplers, one of each type, were installed at each cluster location. Water samples were obtained from 13 of the 15 samplers and submitted to Martin Marietta for analysis. All three samplers performed satisfactorily when considering ease of installation, required in-hole development, and ability to collect water samples from the vadose zone. Advantages and disadvantages of each sampler type are discussed in the main report

  11. Solubility - eSOL | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ta file File name: esol.zip File URL: ftp://ftp.biosciencedbc.jp/archive/esol/LAT... License Update History of This Database Site Policy | Contact Us Solubility - eSOL | LSDB Archive ...

  12. CHOMIK -Sampling Device of Penetrating Type for Russian Phobos Sample Return Mission

    Science.gov (United States)

    Seweryn, Karol; Grygorczuk, Jerzy; Rickmann, Hans; Morawski, Marek; Aleksashkin, Sergey; Banaszkiewicz, Marek; Drogosz, Michal; Gurgurewicz, Joanna; Kozlov, Oleg E.; Krolikowska-Soltan, Malgorzata; Sutugin, Sergiej E.; Wawrzaszek, Roman; Wisniewski, Lukasz; Zakharov, Alexander

    Measurements of physical properties of planetary bodies allow to determine many important parameters for scientists working in different fields of research. For example effective heat conductivity of the regolith can help with better understanding of processes occurring in the body interior. Chemical and mineralogical composition gives us a chance to better understand the origin and evolution of the moons. In principle such parameters of the planetary bodies can be determined based on three different measurement techniques: (i) in situ measurements (ii) measurements of the samples in laboratory conditions at the Earth and (iii) remote sensing measurements. Scientific missions which allow us to perform all type of measurements, give us a chance for not only parameters determination but also cross calibration of the instruments. Russian Phobos Sample Return (PhSR) mission is one of few which allows for all type of such measurements. The spacecraft will be equipped with remote sensing instruments like: spectrometers, long wave radar and dust counter, instruments for in-situ measurements -gas-chromatograph, seismometer, thermodetector and others and also robotic arm and sampling device. PhSR mission will be launched in November 2011 on board of a launch vehicle Zenit. About a year later (11 months) the vehicle will reach the Martian orbit. It is anticipated that it will land on Phobos in the beginning of 2013. A take off back will take place a month later and the re-entry module containing a capsule that will hold the soil sample enclosed in a container will be on its way back to Earth. The 11 kg re-entry capsule with the container will land in Kazakhstan in mid-2014. A unique geological penetrator CHOMIK dedicated for the Phobos Sample Return space mis-sion will be designed and manufactured at the Space Mechatronics and Robotics Laboratory, Space Research Centre Polish Academy of Sciences (SRC PAS) in Warsaw. Functionally CHOMIK is based on the well known MUPUS

  13. Halogenated organic compounds in archived whale oil: A pre-industrial record

    International Nuclear Information System (INIS)

    Teuten, Emma L.; Reddy, Christopher M.

    2007-01-01

    To provide additional evidence that several halogenated organic compounds (HOCs) found in environmental samples are natural and not industrially produced, we analyzed an archived whale oil sample collected in 1921 from the last voyage of the whaling ship Charles W. Morgan. This sample, which pre-dates large-scale industrial manufacture of HOCs, contained two methoxylated polybrominated diphenyl ethers (MeO-PBDEs), five halogenated methyl bipyrroles (MBPs), one halogenated dimethyl bipyrrole (DMBP), and tentatively one dimethoxylated polybrominated biphenyl (diMeO-PBB). This result indicates, at least in part, a natural source of the latter compounds. - Nine halogenated organic compounds have been detected in archived whale oil from the early 1920s

  14. Halogenated organic compounds in archived whale oil: A pre-industrial record

    Energy Technology Data Exchange (ETDEWEB)

    Teuten, Emma L. [Department of Marine Chemistry and Geochemistry, Woods Hole Oceanographic Institution, 360 Woods Hole Road, Woods Hole, MA 02543 (United States)]. E-mail: emma.teuten@plymouth.ac.uk; Reddy, Christopher M. [Department of Marine Chemistry and Geochemistry, Woods Hole Oceanographic Institution, 360 Woods Hole Road, Woods Hole, MA 02543 (United States)]. E-mail: creddy@whoi.edu

    2007-02-15

    To provide additional evidence that several halogenated organic compounds (HOCs) found in environmental samples are natural and not industrially produced, we analyzed an archived whale oil sample collected in 1921 from the last voyage of the whaling ship Charles W. Morgan. This sample, which pre-dates large-scale industrial manufacture of HOCs, contained two methoxylated polybrominated diphenyl ethers (MeO-PBDEs), five halogenated methyl bipyrroles (MBPs), one halogenated dimethyl bipyrrole (DMBP), and tentatively one dimethoxylated polybrominated biphenyl (diMeO-PBB). This result indicates, at least in part, a natural source of the latter compounds. - Nine halogenated organic compounds have been detected in archived whale oil from the early 1920s.

  15. Seabird tissue archival and monitoring project: Protocol for collecting and banking seabird eggs

    Science.gov (United States)

    Weston-York, Geoff; Porter, Barbara J.; Pugh, Rebecca S.; Roseneau, David G.; Simac, Kristin S.; Becker, Paul R.; Thorsteinson, Lyman K.; Wise, Stephen A.

    2001-01-01

    Archiving biological and environmental samples for retrospective analysis is a major component of systematic environmental monitoring. The long-term storage of carefully selected, representative samples in an environmental specimen bank is an important complement to the real-time monitoring of the environment. These archived samples permit:The use of subsequently developed innovative analytical technology that was not available at the time the samples were archived, for clear state-of-art identification an~ quantification of analytes of interest,The identification and quantification of analytes that are of subsequent interest but that were not of interest at the time the samples were archived, andThe comparison of present and past analytical techniques and values, providing continued credibility of past analytical values, and allowing flexibility in environmental monitoring programs.Seabirds, including albatrosses, pelicans, cormorants, terns, kittiwakes, murres, guillemots, and puffins spend most of their lives at sea and have special adaptations for feeding in the marine environment, including the ability to excrete the excess salt obtained from ingesting seawater. Many species nest in dense groups (colonies) on steep, precipitous sea-cliffs and headlands.Seabirds are long-lived and slow to mature. They occupy high positions in the marine food web and are considered sensitive indicators for the marine environment (prey includes krill, small fish, and squid). Breeding success, timing of nesting, diets, and survival rates may provide early indications of changing environmental conditions (e.g., see Hatch et aI., 1993). Chemical analysis of seabird tissues, including egg contents, can be particularly useful in determining whether contaminants (and potential biological effects) associated with human industrial activities, such as offshore petroleum and mineral exploration and development, are accumulating in marine environments. The collection and archival of seabird

  16. Open archive solutions to traditional archive/library cooperation

    Directory of Open Access Journals (Sweden)

    Donatella Castelli

    2003-09-01

    Full Text Available The diffusion of Internet is changing the role of archives and libraries and it is opening a wide range of new possibilities. The new vision is that in few years it will be possible to cross-access multiple libraries, archives, museums, and data repositories. The implementation of this revolutionary vision requires the solution of a number of technical, organizational, sociological, and economical issues. Recently, the proposal of a new, low cost technical solution for open repositories of pre-print material, the Open Archives Initiative Protocol for Metadata Harvesting ( OAI-PMH, has greatly stimulated the discussion about these issues in many application frameworks. This paper overviews the status of this discussion in the library and conventional archives frameworks.

  17. Main - TP Atlas | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...me: tp_atlas_en.zip File URL: ftp://ftp.biosciencedbc.jp/archive/tp_atlas/LATEST/...d License Update History of This Database Site Policy | Contact Us Main - TP Atlas | LSDB Archive ...

  18. Device for electrochemical detection of metal sample surface resistance and passivation against corrosion in electrolyte

    International Nuclear Information System (INIS)

    Urbancik, L.; Bar, J.; Nemec, J.; Sima, A.

    1986-01-01

    The device consists of a teflon vessel with sealing and an opening below the electrolyte level. Into it is submerged an electrode connected to a dc voltage supply whose other pole is connected to a sample of the metal which is pressed to the opening in the sealing with a flexible strap. The teflon vessel and the sealing are integral. The device is simpler and less costly than those manufactured so far. The operating capability of damaged sealing may be renewed by simple mechanical working. The device may be used for detecting the resistance and passivation of steam generator metal tubes. (J.B.). 1 fig

  19. Main - AT Atlas | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ... name: at_atlas_en.zip File URL: ftp://ftp.biosciencedbc.jp/archive/at_atlas/LATE... Database Description Download License Update History of This Database Site Policy | Contact Us Main - AT Atlas | LSDB Archive ...

  20. Flat Files - JSNP | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ... Data file File name: jsnp_flat_files File URL: ftp://ftp.biosciencedbc.jp/archiv...his Database Database Description Download License Update History of This Database Site Policy | Contact Us Flat Files - JSNP | LSDB Archive ...

  1. OPS index - KOME | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...listed. Data file File name: kome_ops_index.zip File URL: ftp://ftp.biosciencedbc.jp/archive/kome/LATEST/kom...e History of This Database Site Policy | Contact Us OPS index - KOME | LSDB Archive ...

  2. Clone - ClEST | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...le URL: ftp://ftp.biosciencedbc.jp/archive/clest/LATEST/clest_clone.zip File size: 660 KB Simple search URL ...ion Download License Update History of This Database Site Policy | Contact Us Clone - ClEST | LSDB Archive ...

  3. Image files - RPD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ftp://ftp.biosciencedbc.jp/archive/rpd/LATEST/rpd_gel_image.zip File size: 38.5 MB Simple search URL - Data ... License Update History of This Database Site Policy | Contact Us Image files - RPD | LSDB Archive ...

  4. Protein - AT Atlas | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ..._protein.zip File URL: ftp://ftp.biosciencedbc.jp/archive/at_atlas/LATEST/at_atla...About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Protein - AT Atlas | LSDB Archive ...

  5. Cluster - ClEST | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...e File name: clest_cluster.zip File URL: ftp://ftp.biosciencedbc.jp/archive/clest/LATEST/clest_cluster.zip F...ownload License Update History of This Database Site Policy | Contact Us Cluster - ClEST | LSDB Archive ...

  6. Incore instrumentation device

    International Nuclear Information System (INIS)

    Fujita, Kazuhiko.

    1996-01-01

    A position of a detector is detected by a driving device, and the detected values are sampled by a newly disposed central processing unit for sampling the detected values depending on the sampling position of the detected values. Since the sampling position of the detected values is detected by the driving device, the sampling position for the detection values does not rely on the speed of the driving motor of the driving device. The load on the central processing device for controlling the device is lowered by newly disposing the central processing unit for sampling detected values. When the values for the position of the detector counted after conversion to digital values reach the digital values corresponding to the detection value sampling position outputted from the central processing unit for controlling the device, a counted value comparison circuit causes the central processing unit for controlling the device to sample the detection values outputted from the detector. Then, the processing speed can be increased without interruption processings, which can save the central processing unit for sampling detection values. In addition, software can be simplified and loads can be lowered. (N.H.)

  7. Researchers’ Attitudes and Behaviour to Data Archiving Policies and Practice is Typified by Low Awareness and Little Planning. A Review of: Perry, Carol Marie. “Archiving of Publicly Funded Research Data: A Survey of Canadian Researchers.” Government Information Quarterly 25 (2008: 133-48.

    Directory of Open Access Journals (Sweden)

    Gaby Haddow

    2008-12-01

    Full Text Available Objective – To assess researchers’ attitudes and behaviours in relation to archiving research data and to determine researchers’views about policies relating to data archiving.Design – Survey.Setting – Canadian universities.Subjects – Social sciences and humanities researchers from universities across Canada.Methods – A questionnaire comprising 15 questions was mailed to 175 researchers randomly sampled from a publicly available list of 5,821 individuals who had received grants and awards from the Social Sciences and Humanities Research Council of Canada (SSHRC. From this sample, 75 (43.4% responded within the five week time-frame stipulated. The questionnaire was constructed using four existing surveys and asked researchers for information about: geographical location, years of research experience, research funding sources, current plans to archive research data, awareness of archiving policies, attitude to mandated research data archiving, effect of mandatory data archiving policies on grant-seeking, attitude to making archived research data accessible, and use of research data collected by others. The questionnaire also included space for respondents to make comments. Responses to each question were analyzed, followed by a series of cross-analyses to investigate associations between findings. These cross-analyses include: whether attitudes to making data accessible differed according to length of experience, support for a national archive initiative, or agreement with a mandatory policy; and whether plans to archive research data were associated with awareness of policy, agreement with mandatory policy, or funding from government agencies other than SSHRC. Some cross-analyses were conducted between responses to questions and the comments provided by respondents. Most of the questionnaire responses were analyzed as percentages in two categories only. For example, length of service responses were presented as “up to 20years

  8. Gel table - RPD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...d_main.zip File URL: ftp://ftp.biosciencedbc.jp/archive/rpd/LATEST/rpd_main.zip File size: 1 KB Simple searc...iption Download License Update History of This Database Site Policy | Contact Us Gel table - RPD | LSDB Archive ...

  9. tRNA - RMG | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...File URL: ftp://ftp.biosciencedbc.jp/archive/rmg/LATEST/rmg_trna.zip File size: 1 KB Simple search URL http:...ption Download License Update History of This Database Site Policy | Contact Us tRNA - RMG | LSDB Archive ...

  10. Enhancers - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM...d phase2.0 Data file File name: Enhancers File URL: ftp://ftp.biosciencedbc.jp/archive/fantom...load License Update History of This Database Site Policy | Contact Us Enhancers - FANTOM5 | LSDB Archive ...

  11. Sample information - RED | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available type C : Control sample T : Target sample treatment Keyword Treatment keyword Physiology1 Physiological con...Cultivar Tissue stage detail Details of tissue stage stage Keyword Developmental stage other stage Keyword... Other developmental stage tissue Keyword Collected organ other tissue Keyword Othe

  12. Integration of continuous-flow sampling with microchip electrophoresis using poly(dimethylsiloxane)-based valves in a reversibly sealed device.

    Science.gov (United States)

    Li, Michelle W; Martin, R Scott

    2007-07-01

    Here we describe a reversibly sealed microchip device that incorporates poly(dimethylsiloxane) (PDMS)-based valves for the rapid injection of analytes from a continuously flowing stream into a channel network for analysis with microchip electrophoresis. The microchip was reversibly sealed to a PDMS-coated glass substrate and microbore tubing was used for the introduction of gas and fluids to the microchip device. Two pneumatic valves were incorporated into the design and actuated on the order of hundreds of milliseconds, allowing analyte from a continuously flowing sampling stream to be injected into an electrophoresis separation channel. The device was characterized in terms of the valve actuation time and pushback voltage. It was also found that the addition of sodium dodecyl sulfate (SDS) to the buffer system greatly increased the reproducibility of the injection scheme and enabled the analysis of amino acids derivatized with naphthalene-2,3-dicarboxaldehyde/cyanide. Results from continuous injections of a 0.39 nL fluorescein plug into the optimized system showed that the injection process was reproducible (RSD of 0.7%, n = 10). Studies also showed that the device was capable of monitoring off-chip changes in concentration with a device lag time of 90 s. Finally, the ability of the device to rapidly monitor on-chip concentration changes was demonstrated by continually sampling from an analyte plug that was derivatized upstream from the electrophoresis/continuous flow interface. A reversibly sealed device of this type will be useful for the continuous monitoring and analysis of processes that occur either off-chip (such as microdialysis sampling) or on-chip from other integrated functions.

  13. All 5' EST - KOME | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...n of data contents 5' EST sequences Data file File name: CSV: kome_est_5end_all.zip File URL: ftp://ftp.biosciencedbc.jp/archiv...fasta.zip File URL: ftp://ftp.biosciencedbc.jp/archive/kome/LATEST/kome_est_5end_...se Description Download License Update History of This Database Site Policy | Contact Us All 5' EST - KOME | LSDB Archive ...

  14. All 3' EST - KOME | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...n of data contents 3' EST sequences Data file File name: CSV: kome_est_3end_all.zip File URL: ftp://ftp.biosciencedbc.jp/archiv...fasta.zip File URL: ftp://ftp.biosciencedbc.jp/archive/kome/LATEST/kome_est_3end_...se Description Download License Update History of This Database Site Policy | Contact Us All 3' EST - KOME | LSDB Archive ...

  15. About Libraries - AcEST | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ormat text file. Data file File name: acest_library.zip File URL: ftp://ftp.biosciencedbc.jp/archive/acest/L...ATEST/acest_library.zip File size: 2KB Simple search URL http://togodb.biosciencedbc.jp/togodb/view/archiv...s Database Database Description Download License Update History of This Database Site Policy | Contact Us About Libraries - AcEST | LSDB Archive ...

  16. The Dora Lange Archive

    DEFF Research Database (Denmark)

    Holm, Isak Winkel; Bjering, Jens Christian Borrebye

    2016-01-01

    The first season of Nic Pizzolatto's True Detective (2014) is not only a show about a murder, but also a show about how to gather and organize information in an archive. Having identified two archival problems—its temporal and topical extension—the article turns to Jacques Derrida's Archive Fever......: a Freudian Impression in order to explain how the archiving problems of the crime investigation are, in fact, intrinsic to any archiving practice. Lastly, the article addresses the political significance of the show's archiving problems by help of Derrida's text on the American Constitution and of Hardt...

  17. Free radicals induced archive paper by irradiation

    International Nuclear Information System (INIS)

    Cutrubinis, M.; Moise, I.V.; Negut, C.D.; Georgescu, R.; Suvaila, R.; Virgolici, M.; Manea, M.M.

    2011-01-01

    Complete text of publication follows. Irradiation of archive paper (document archives of institutions, companies etc. and library or museum collections of books and documents) can solve the problems related to the bio-deterioration and bio-contamination of paper and sometimes save valuable cultural heritage paper items. For valuable paper items care should be taken to the degradation induced instantly by the ionising radiation to the cellulosic support and also to the long term post-irradiation effects. The free radicals formed due to the irradiation treatment could contribute to instant degradation of paper. Part of them are also trapped for months and years after irradiation and they could be related to the post-irradiation effects in paper items. In this study, different sorts of cellulosic support samples (soft wood and hard wood cellulose, contemporary paper, paper from archives and from collections etc.) have been irradiated with dosis up to 100 kGy and the radiation induced free radicals have been measured by ESR spectrometry. The ESR signals have shown the type and quantity of radiation induced free radicals. Their study can be used for a realistic estimation of the degradative effect of the ionising radiation treatment of archive paper.

  18. Main data - RMG | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ftp://ftp.biosciencedbc.jp/archive/rmg/LATEST/rmg_main.zip File size: 1 KB Simple search URL http://togodb.b... This Database Database Description Download License Update History of This Database Site Policy | Contact Us Main data - RMG | LSDB Archive ...

  19. PREIMS - AT Atlas | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...Targeted Proteins Research Program (TPRP). Data file File name: at_atlas_preims.zip File URL: ftp://ftp.biosciencedbc.jp/archiv...base Database Description Download License Update History of This Database Site Policy | Contact Us PREIMS - AT Atlas | LSDB Archive ...

  20. EST data - RED | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...st.zip File URL: ftp://ftp.biosciencedbc.jp/archive/red/LATEST/red_est.zip File size: 629 KB Simple search U...ase Database Description Download License Update History of This Database Site Policy | Contact Us EST data - RED | LSDB Archive ...

  1. ORF information - KOME | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ... File URL: ftp://ftp.biosciencedbc.jp/archive/kome/LATEST/kome_orf_infomation.zip File size: 526 KB Simple s...ut This Database Database Description Download License Update History of This Database Site Policy | Contact Us ORF information - KOME | LSDB Archive ...

  2. Automated Archiving of Archaeological Aerial Images

    Directory of Open Access Journals (Sweden)

    Michael Doneus

    2016-03-01

    Full Text Available The main purpose of any aerial photo archive is to allow quick access to images based on content and location. Therefore, next to a description of technical parameters and depicted content, georeferencing of every image is of vital importance. This can be done either by identifying the main photographed object (georeferencing of the image content or by mapping the center point and/or the outline of the image footprint. The paper proposes a new image archiving workflow. The new pipeline is based on the parameters that are logged by a commercial, but cost-effective GNSS/IMU solution and processed with in-house-developed software. Together, these components allow one to automatically geolocate and rectify the (oblique aerial images (by a simple planar rectification using the exterior orientation parameters and to retrieve their footprints with reasonable accuracy, which is automatically stored as a vector file. The data of three test flights were used to determine the accuracy of the device, which turned out to be better than 1° for roll and pitch (mean between 0.0 and 0.21 with a standard deviation of 0.17–0.46 and better than 2.5° for yaw angles (mean between 0.0 and −0.14 with a standard deviation of 0.58–0.94. This turned out to be sufficient to enable a fast and almost automatic GIS-based archiving of all of the imagery.

  3. 3D site specific sample preparation and analysis of 3D devices (FinFETs) by atom probe tomography.

    Science.gov (United States)

    Kambham, Ajay Kumar; Kumar, Arul; Gilbert, Matthieu; Vandervorst, Wilfried

    2013-09-01

    With the transition from planar to three-dimensional device architectures such as Fin field-effect-transistors (FinFETs), new metrology approaches are required to meet the needs of semiconductor technology. It is important to characterize the 3D-dopant distributions precisely as their extent, positioning relative to gate edges and absolute concentration determine the device performance in great detail. At present the atom probe has shown its ability to analyze dopant distributions in semiconductor and thin insulating materials with sub-nm 3D-resolution and good dopant sensitivity. However, so far most reports have dealt with planar devices or restricted the measurements to 2D test structures which represent only limited challenges in terms of localization and site specific sample preparation. In this paper we will discuss the methodology to extract the dopant distribution from real 3D-devices such as a 3D-FinFET device, requiring the sample preparation to be carried out at a site specific location with a positioning accuracy ∼50 nm. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Mapping data - KOME | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...tional Rice Genome Sequencing Project (IRGSP) Data file File name: kome_mapping_data.zip File URL: ftp://ftp.biosciencedbc.jp/archiv...(Transcriptional Unit) About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Mapping data - KOME | LSDB Archive ...

  5. Spot table - RPD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...d_spot.zip File URL: ftp://ftp.biosciencedbc.jp/archive/rpd/LATEST/rpd_spot.zip F... cDNA. (multiple entries) About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Spot table - RPD | LSDB Archive ...

  6. Archival standards, in archival open access software And offer appropriate software for internal archival centers

    Directory of Open Access Journals (Sweden)

    Abdolreza Izadi

    2016-12-01

    Full Text Available The purpose of this study is Study of Descriptive Metadata Standards in Archival open source software, to determine the most appropriate descriptive metadata standard (s and also Encoder Software support of these standards. The approach of present study is combination and library methods, Delphi and descriptive survey are used. Data gathering in library study is fiche, in the Delphi method is questionnaire and in descriptive survey is checklist. Statistical population contains 5 Archival open source software. The findings suggest that 5 metadata standards, consist of EAD, ISAD, EAC-CPF, ISAAR & ISDF, diagnosed appropriate by Delphi Panel members as the most appropriate descriptive metadata standards to use for archival software. Moreover, ICA-ATOM and Archivist toolkit in terms of support for standards that were suitable, diagnosed as the most appropriate archival software.

  7. High sensitivity high-resolution full range relaxometry using a fast mechanical sample shuttling device and a cryo-probe

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Ching-Yu [Université Paris-Saclay, NIMBE, CEA, CNRS (France); Chu, Minglee [Academia Sinica, Institute of Physics (China); Chang, Chi-Fon [Academia Sinica, Genomics Research Center (China); Yu, Tsunai; Huang, Tai-huang, E-mail: bmthh@gate.sinica.edu.tw [Academia Sinica, Institute of Biomedical Science (China); Sakellariou, Dimitris, E-mail: dimitrios.sakellariou@cea.fr [Université Paris-Saclay, NIMBE, CEA, CNRS (France)

    2016-11-15

    Field-dependent NMR studies of bio-molecular systems using a sample shuttling hardware operating on a high-field NMR apparatus have provided valuable structural and dynamic information. We have recently published a design of a compact sample transportation device, called “field-cycler”, which was installed in a commercial spectrometer and which provided highly precise positioning and stability during high speed shuttling. In this communication, we demonstrate the first use of a sample shuttling device on a commercial high field standard bore NMR spectrometer, equipped with a commercial triple resonance cryogenically cooled NMR probe. The performance and robustness of the hardware operating in 1D and 2D field cycling experiments, as well as the impact of the sample shuttling time on the signal intensity are discussed.

  8. Sampling inspection device

    International Nuclear Information System (INIS)

    Chiba, Keiichi.

    1996-01-01

    A holder is inserted to a holder guide, and is stopped at a position where one end of a hook disposed to the holder is not in contact with the holder guide (a position where hooks do not work). A cap incorporated with wiping paper is pushed up into a holder by a device rod with the wiping paper situated downwardly. The hooks of the holder are engaged to the grooves of the cap to secure the cap. The holder is moved to a predetermined place to wipe off the deposited materials on the surface of a vessel which contains radioactive wastes. Then, the holder is inserted to the holder guide, and is stopped at a position where the one end of the holder is raised. The securement of the gap is released, the cap is forced into a recovering cover by a discharging rod. The hooks of the recovering cover are caught by the grooves of the cap to secure the cap. Then, the cap is transported to a radioactivity measuring chamber. (I.N.)

  9. VLBA Archive &Distribution Architecture

    Science.gov (United States)

    Wells, D. C.

    1994-01-01

    Signals from the 10 antennas of NRAO's VLBA [Very Long Baseline Array] are processed by a Correlator. The complex fringe visibilities produced by the Correlator are archived on magnetic cartridges using a low-cost architecture which is capable of scaling and evolving. Archive files are copied to magnetic media to be distributed to users in FITS format, using the BINTABLE extension. Archive files are labelled using SQL INSERT statements, in order to bind the DBMS-based archive catalog to the archive media.

  10. (reprocessed)CAGE peaks - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM...g38/mm10). Data file File name: (reprocessed)CAGE_peaks (Homo sapiens) File URL: ftp://ftp.biosciencedbc.jp/archive/fantom...)CAGE_peaks (Mus musculus) File URL: ftp://ftp.biosciencedbc.jp/archive/fantom5/d...his Database Site Policy | Contact Us (reprocessed)CAGE peaks - FANTOM5 | LSDB Archive ...

  11. (reprocessed)pooled_ctss - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM...e: (reprocessed)pooled_ctss (Homo sapiens) File URL: ftp://ftp.biosciencedbc.jp/archive/fantom5/datafiles/re...) File URL: ftp://ftp.biosciencedbc.jp/archive/fantom5/datafiles/reprocessed/mm10...ory of This Database Site Policy | Contact Us (reprocessed)pooled_ctss - FANTOM5 | LSDB Archive ...

  12. License - PSCDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...wnload License Update History of This Database Site Policy | Contact Us License - PSCDB | LSDB Archive ...

  13. Download - RPSD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...Download License Update History of This Database Site Policy | Contact Us Download - RPSD | LSDB Archive ...

  14. License - DMPD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ownload License Update History of This Database Site Policy | Contact Us License - DMPD | LSDB Archive ...

  15. Disease - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...File name: disease.tar.gz File URL: ftp://ftp.biosciencedbc.jp/archive/microbedb/...iption Download License Update History of This Database Site Policy | Contact Us Disease - MicrobeDB.jp | LSDB Archive ...

  16. Incremental picture archiving and communication system (PACS) - an appraisal

    International Nuclear Information System (INIS)

    Nagle, K.

    2000-01-01

    Digital storage phosphor radiography is slowly being introduced in Australia with more sites making the conversion from film/screen to computed radiography or a fully integrated Picture Archiving and Communication System (PACS). St Vincent's Hospital, Melbourne (SVHM) introduced partial PACS for general radiography in June 1996. This involved networking two Fuji CR Image Plate Readers and an existing Kodak KESPR400 Reader with viewing stations strategically placed in Medical Imaging, Casualty and the Intensive and Coronary Care units. No long-term storage device or archive facility was purchased. This installation coincided with the relocation of the Medical Imaging Department (MID) to a fully equipped new site as well as the introduction of the Kestral Radiology Management System. The transition has involved significant changes to the department's design, workflow and the radiographers' work practices. Copyright (1999) Australian Institute of Radiography

  17. PSCID List - PSCDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...t.zip File URL: ftp://ftp.biosciencedbc.jp/archive/pscdb/LATEST/pscdb_pscid_list.zip File size: 24.4 KB Simp...nd-binding sites About This Database Database Description Download License Update History of This Database Site Policy | Contact Us PSCID List - PSCDB | LSDB Archive ...

  18. Download - SSBD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ion Download License Update History of This Database Site Policy | Contact Us Download - SSBD | LSDB Archive ...

  19. Archives: Mathematics Connection

    African Journals Online (AJOL)

    Items 1 - 9 of 9 ... Archives: Mathematics Connection. Journal Home > Archives: Mathematics Connection. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 9 of 9 Items. 2011 ...

  20. Download - DGBY | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...base Description Download License Update History of This Database Site Policy | Contact Us Download - DGBY | LSDB Archive ...

  1. Download - SAHG | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...Database Description Download License Update History of This Database Site Policy | Contact Us Download - SAHG | LSDB Archive ...

  2. Download - Metabolonote | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ... Database Description Download License Update History of This Database Site Policy | Contact Us Download - Metabolonote | LSDB Archive ...

  3. License - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...e Database Description Download License Update History of This Database Site Policy | Contact Us License - GRIPDB | LSDB Archive ...

  4. License - GETDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...se Database Description Download License Update History of This Database Site Policy | Contact Us License - GETDB | LSDB Archive ...

  5. Archives: Philosophical Papers

    African Journals Online (AJOL)

    Items 1 - 26 of 26 ... Archives: Philosophical Papers. Journal Home > Archives: Philosophical Papers. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 26 of 26 Items. 2008. Vol 37 ...

  6. Archives: Kenya Veterinarian

    African Journals Online (AJOL)

    Items 1 - 21 of 21 ... Archives: Kenya Veterinarian. Journal Home > Archives: Kenya Veterinarian. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 21 of 21 Items. 2014. Vol 38, No ...

  7. Archives: Agronomie Africaine

    African Journals Online (AJOL)

    Items 1 - 50 of 55 ... Archives: Agronomie Africaine. Journal Home > Archives: Agronomie Africaine. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 50 of 55 Items, 1 2 > >>. 2017 ...

  8. A Critical Archival Pedagogy: The Lesbian Herstory Archives and a Course in Radical Lesbian Thought

    Directory of Open Access Journals (Sweden)

    Kailah R. Carden

    2016-07-01

    Full Text Available This paper is the story of a critical archival pedagogy that emerged through the undergraduate course Radical Lesbian Thought. As teachers and students, we dialogically co-constructed the praxis and content of the course throughout the semester. We employed archives throughout the course as theory, site, and pedagogy. In this paper we identify three archival frameworks: dialogue and difference, collaborative knowledge production, and archival methodology; and detail how they informed three course activities: reading and writing archival letters, visiting the Lesbian Herstory Archives, and completing final archival projects. We argue that archives provide theoretical and practical opportunities, in the tradition of critical pedagogy, to challenge and rearrange powered classroom structures and practices of thought.

  9. An efficient, robust, and inexpensive grinding device for herbal samples like Cinchona bark

    DEFF Research Database (Denmark)

    Hansen, Steen Honoré; Holmfred, Else Skovgaard; Cornett, Claus

    2015-01-01

    An effective, robust, and inexpensive grinding device for the grinding of herb samples like bark and roots was developed by rebuilding a commercially available coffee grinder. The grinder was constructed to be able to provide various particle sizes, to be easy to clean, and to have a minimum...... of dead volume. The recovery of the sample when grinding as little as 50 mg of crude Cinchona bark was about 60%. Grinding is performed in seconds with no rise in temperature, and the grinder is easily disassembled to be cleaned. The influence of the particle size of the obtained powders on the recovery...

  10. The NASA Ames Life Sciences Data Archive: Biobanking for the Final Frontier

    Science.gov (United States)

    Rask, Jon; Chakravarty, Kaushik; French, Alison J.; Choi, Sungshin; Stewart, Helen J.

    2017-01-01

    The NASA Ames Institutional Scientific Collection involves the Ames Life Sciences Data Archive (ALSDA) and a biospecimen repository, which are responsible for archiving information and non-human biospecimens collected from spaceflight and matching ground control experiments. The ALSDA also manages a biospecimen sharing program, performs curation and long-term storage operations, and facilitates distribution of biospecimens for research purposes via a public website (https:lsda.jsc.nasa.gov). As part of our best practices, a tissue viability testing plan has been developed for the repository, which will assess the quality of samples subjected to long-term storage. We expect that the test results will confirm usability of the samples, enable broader science community interest, and verify operational efficiency of the archives. This work will also support NASA open science initiatives and guides development of NASA directives and policy for curation of biological collections.

  11. License - JSNP | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - JSNP | LSDB Archive ...

  12. Download - ASTRA | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...is Database Database Description Download License Update History of This Database Site Policy | Contact Us Download - ASTRA | LSDB Archive ...

  13. Test Results for Caustic Demand Measurements on Tank 241-AX-101 and Tank 241-AX-103 Archive Samples

    International Nuclear Information System (INIS)

    Doll, Stephanie R.; Bolling, Stacie D.

    2016-01-01

    Caustic demand testing is used to determine the necessary amount of caustic required to neutralize species present in the Hanford tank waste and obtain a target molarity of free hydroxide for tank corrosion control. The presence and quantity of hydroxide-consuming analytes are just as important in determining the caustic demand as is the amount of free hydroxide present. No single data point can accurately predict whether a satisfactory hydroxide level is being met, as it is dependent on multiple factors (e.g., free hydroxide, buffers, amphoteric metal hydroxides, bicarbonate, etc.). This enclosure contains the caustic demand, scanning electron microscopy (SEM), polarized light microscopy (PLM), and X-ray diffraction (XRD) analysis for the tank 241-AX-101 (AX-101) and 241-AX-103 (AX-103) samples. The work was completed to fulfill a customer request outlined in the test plan, WRPS-1505529, ''Test Plan and Procedure for Caustic Demand Testing on Tank 241-AX-101 and Tank 241-AX-103 Archive Samples.'' The work results will provide a baseline to support planned retrieval of AX-101 and AX-103.

  14. Test Results for Caustic Demand Measurements on Tank 241-AX-101 and Tank 241-AX-103 Archive Samples

    Energy Technology Data Exchange (ETDEWEB)

    Doll, Stephanie R. [Washington River Protection Solutions, Richland, WA (United States); Bolling, Stacie D. [Washington River Protection Solutions, Richland, WA (United States)

    2016-07-14

    Caustic demand testing is used to determine the necessary amount of caustic required to neutralize species present in the Hanford tank waste and obtain a target molarity of free hydroxide for tank corrosion control. The presence and quantity of hydroxide-consuming analytes are just as important in determining the caustic demand as is the amount of free hydroxide present. No single data point can accurately predict whether a satisfactory hydroxide level is being met, as it is dependent on multiple factors (e.g., free hydroxide, buffers, amphoteric metal hydroxides, bicarbonate, etc.). This enclosure contains the caustic demand, scanning electron microscopy (SEM), polarized light microscopy (PLM), and X-ray diffraction (XRD) analysis for the tank 241-AX-101 (AX-101) and 241-AX-103 (AX-103) samples. The work was completed to fulfill a customer request outlined in the test plan, WRPS-1505529, “Test Plan and Procedure for Caustic Demand Testing on Tank 241-AX-101 and Tank 241-AX-103 Archive Samples.” The work results will provide a baseline to support planned retrieval of AX-101 and AX-103.

  15. Archives: Water SA

    African Journals Online (AJOL)

    Items 1 - 50 of 71 ... Archives: Water SA. Journal Home > Archives: Water SA. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 50 of 71 Items, 1 2 > >>. 2018. Vol 44, No 1 (2018) ...

  16. License - KOME | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...out This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - KOME | LSDB Archive ...

  17. Download - RED | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...t This Database Database Description Download License Update History of This Database Site Policy | Contact Us Download - RED | LSDB Archive ...

  18. Download - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...t This Database Database Description Download License Update History of This Database Site Policy | Contact Us Download - GRIPDB | LSDB Archive ...

  19. License - RMOS | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...out This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - RMOS | LSDB Archive ...

  20. CAGE peaks - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM...E Data file File name: CAGE_peaks File URL: ftp://ftp.biosciencedbc.jp/archive/fantom... This Database Database Description Download License Update History of This Database Site Policy | Contact Us CAGE peaks - FANTOM5 | LSDB Archive ...

  1. Materials and Life Science Experimental Facility at the Japan Proton Accelerator Research Complex III: Neutron Devices and Computational and Sample Environments

    Directory of Open Access Journals (Sweden)

    Kaoru Sakasai

    2017-08-01

    Full Text Available Neutron devices such as neutron detectors, optical devices including supermirror devices and 3He neutron spin filters, and choppers are successfully developed and installed at the Materials Life Science Facility (MLF of the Japan Proton Accelerator Research Complex (J-PARC, Tokai, Japan. Four software components of MLF computational environment, instrument control, data acquisition, data analysis, and a database, have been developed and equipped at MLF. MLF also provides a wide variety of sample environment options including high and low temperatures, high magnetic fields, and high pressures. This paper describes the current status of neutron devices, computational and sample environments at MLF.

  2. License - ASTRA | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ... notice. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - ASTRA | LSDB Archive ...

  3. License - SSBD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...thout notice. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - SSBD | LSDB Archive ...

  4. Download - PSCDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...cess [here]. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Download - PSCDB | LSDB Archive ...

  5. License - SAHG | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ut notice. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - SAHG | LSDB Archive ...

  6. License - RPSD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...thout notice. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - RPSD | LSDB Archive ...

  7. Private political archives

    Directory of Open Access Journals (Sweden)

    Waldemar Chorążyczewski

    2010-12-01

    Full Text Available "Private political archives" are understood by me as all acts collected intently by a private person. These acts are connected with the person's participation in political life and gathered in order to be used in public activity as the source of argumentation and information about factors and mechanisms of political processes. Private political archives of the first half of the XVI century were mainly created by royal servants, often with reference to their job duties. These duties could inspire to collect political acts for private purposes. During the reign of Sigismund Augustus, archives of gentry activists were developed to small extent and they mainly focused on parliamentary life. Private political archives were created outside the executionist movement, namely in the community gathered around the royal court. After 1572, Crown and Lithuanian magnates greatly influenced the creation of political archives. Archives of lesser gentry, scarce and poor, did not disappear completely. However, they became difficult for identification. Therefore, developmental process concerned exclusively documentary "treasure troves" created by magnates. They had the financial means and possibilities to create truly valuable political archives. The same as in the previous period the dynamisms of executionist movement was reflected in political archival documentation, now the creation of patronage system and clientele, or traditionally understood magnate oligarchy, (depending on the point of view corresponded best to archives development. The heritage of previous generations was the treasure trove of patterns and solutions. However, this trove was used selectively, on one hand giving up patterns and rights that were uncomfortable, and, on the other, giving the value of precedence to unexpected acts that gained more importance or even new content in changed political conditions. The application of interpretation principle raised interest in old acts and patterns

  8. BRC - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...table). Data file File name: brc.tar.gz File URL: ftp://ftp.biosciencedbc.jp/archive/microbedb/LATEST/brc.ta...rains in JCM. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us BRC - MicrobeDB.jp | LSDB Archive ...

  9. SRA - MicrobeDB.jp | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...e following table). Data file File name: sra.tar.gz File URL: ftp://ftp.biosciencedbc.jp/archive/microbedb/L...t This Database Database Description Download License Update History of This Database Site Policy | Contact Us SRA - MicrobeDB.jp | LSDB Archive ...

  10. Archives: ORiON

    African Journals Online (AJOL)

    Items 1 - 27 of 27 ... Archives: ORiON. Journal Home > Archives: ORiON. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 27 of 27 Items. 2017. Vol 33, No 2 (2017) · Vol 33, No 1 ...

  11. POLYP: an automatic device for drawing sequential samples of gas

    Energy Technology Data Exchange (ETDEWEB)

    Gaglione, P; Koechler, C; Stanchi, L

    1974-12-01

    Polyp is an automatic device consisting of electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. The other seven pumps will inflate sequentially the other bags. The instrument is powered by rechargeable batteries and realized with C-MUS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof.

  12. POLYP: an automatic device for drawing sequential samples of gas

    International Nuclear Information System (INIS)

    Gaglione, P.; Koechler, C.; Stanchi, L.

    1974-12-01

    POLYP is an automatic device consisting of an electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. Thereafter the other seven pumps will inflate sequentially the other bag. The instrument is powered by rechargeable batteries and realized with C-MOS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof

  13. In planta passive sampling devices for assessing subsurface chlorinated solvents.

    Science.gov (United States)

    Shetty, Mikhil K; Limmer, Matt A; Waltermire, Kendra; Morrison, Glenn C; Burken, Joel G

    2014-06-01

    Contaminant concentrations in trees have been used to delineate groundwater contaminant plumes (i.e., phytoscreening); however, variability in tree composition hinders accurate measurement of contaminant concentrations in planta, particularly for long-term monitoring. This study investigated in planta passive sampling devices (PSDs), termed solid phase samplers (SPSs) to be used as a surrogate tree core. Characteristics studied for five materials included material-air partitioning coefficients (Kma) for chlorinated solvents, sampler equilibration time and field suitability. The materials investigated were polydimethylsiloxane (PDMS), low-density polyethylene (LDPE), linear low-density polyethylene (LLDPE), polyoxymethylene (POM) and plasticized polyvinyl chloride (PVC). Both PDMS and LLDPE samplers demonstrated high partitioning coefficients and diffusivities and were further tested in greenhouse experiments and field trials. While most of the materials could be used for passive sampling, the PDMS SPSs performed best as an in planta sampler. Such a sampler was able to accurately measure trichloroethylene (TCE) and tetrachloroethylene (PCE) concentrations while simultaneously incorporating simple operation and minimal impact to the surrounding property and environment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. A novel device for batch-wise isolation of α-cellulose from small-amount wholewood samples

    OpenAIRE

    T. Wieloch; Gerhard Helle; Ingo Heinrich; Michael Voigt; P. Schyma

    2011-01-01

    A novel device for the chemical isolation of α-cellulose from wholewood material of tree rings was designed by the Potsdam Dendro Laboratory. It allows the simultaneous treatment of up to several hundred micro samples. Key features are the batch-wise exchange of the chemical solutions, the reusability of all major parts and the easy and unambiguous labelling of each individual sample. Compared to classical methods labour intensity and running costs are significantly reduced.

  15. Download - RPD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data .... If it is, access [here]. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Download - RPD | LSDB Archive ...

  16. License - RED | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ts might be changed without notice. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - RED | LSDB Archive ...

  17. Download - JSNP | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data .... If it is, access [here]. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Download - JSNP | LSDB Archive ...

  18. Novel device to sample the esophageal microbiome--the esophageal string test.

    Directory of Open Access Journals (Sweden)

    Sophie A Fillon

    Full Text Available A growing number of studies implicate the microbiome in the pathogenesis of intestinal inflammation. Previous work has shown that adults with esophagitis related to gastroesophageal reflux disease have altered esophageal microbiota compared to those who do not have esophagitis. In these studies, sampling of the esophageal microbiome was accomplished by isolating DNA from esophageal biopsies obtained at the time of upper endoscopy. The aim of the current study was to identify the esophageal microbiome in pediatric individuals with normal esophageal mucosa using a minimally invasive, capsule-based string technology, the Enterotest™. We used the proximal segment of the Enterotest string to sample the esophagus, and term this the "Esophageal String Test" (EST. We hypothesized that the less invasive EST would capture mucosal adherent bacteria present in the esophagus in a similar fashion as mucosal biopsy. EST samples and mucosal biopsies were collected from children with no esophageal inflammation (n = 15 and their microbiome composition determined by 16S rRNA gene sequencing. Microbiota from esophageal biopsies and ESTs produced nearly identical profiles of bacterial genera and were different from the bacterial contents of samples collected from the nasal and oral cavity. We conclude that the minimally invasive EST can serve as a useful device for study of the esophageal microbiome.

  19. Movie collection - TogoTV | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...ols. Data file File name: movie File URL: ftp://ftp.biosciencedbc.jp/archive/togotv/movie/ File size: 200 GB...ata entries 1169 entries - About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Movie collection - TogoTV | LSDB Archive ...

  20. License - GenLibi | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...nse Update History of This Database Site Policy | Contact Us License - GenLibi | LSDB Archive ...

  1. License - ClEST | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...License Update History of This Database Site Policy | Contact Us License - ClEST | LSDB Archive ...

  2. The ERASMUS experiment archive

    Science.gov (United States)

    Isakeit, Dieter; Sabbatini, Massimo; Carey, William

    2005-08-01

    The Erasmus Experiment Archive is an electronic database, accessible through the Internet, that collects in a single reference repository scientific, technical and operational information regarding the experiments performed in the experiment facilities which fall under the responsibility of the ESA Directorate of Human Spaceflight, Microgravity and Exploration. The archive is operated, filled with content and kept up-to-date by the Erasmus User Centre. which forms part of the Directorate. The archive shares its records and is interoperable with similar experiment archives of the partner agencies NASA USA) and JAXA (Japan) through a mutually agreed standard for experiment records called the International Distributed Experiment Archive (IDEA).

  3. Body weight - Open TG-GATEs | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...le URL: ftp://ftp.biosciencedbc.jp/archive/open-tggates/LATEST/open_tggates_body_...atabase Description Download License Update History of This Database Site Policy | Contact Us Body weight - Open TG-GATEs | LSDB Archive ...

  4. Liquid waste sampling device

    International Nuclear Information System (INIS)

    Kosuge, Tadashi

    1998-01-01

    A liquid pumping pressure regulator is disposed on the midway of a pressure control tube which connects the upper portion of a sampling pot and the upper portion of a liquid waste storage vessel. With such a constitution, when the pressure in the sampling pot is made negative, and liquid wastes are sucked to the liquid pumping tube passing through the sampling pot, the difference between the pressure on the entrance of the liquid pumping pressure regulator of the pressure regulating tube and the pressure at the bottom of the liquid waste storage vessel is made constant. An opening degree controlling meter is disposed to control the degree of opening of a pressure regulating valve for sending actuation pressurized air to the liquid pumping pressure regulator. Accordingly, even if the liquid level of liquid wastes in the liquid waste storage vessel is changed, the height for the suction of the liquid wastes in the liquid pumping tube can be kept constant. With such procedures, sampling can be conducted correctly, and the discharge of the liquid wastes to the outside can be prevented. (T.M.)

  5. Incorporating Oracle on-line space management with long-term archival technology

    Science.gov (United States)

    Moran, Steven M.; Zak, Victor J.

    1996-01-01

    The storage requirements of today's organizations are exploding. As computers continue to escalate in processing power, applications grow in complexity and data files grow in size and in number. As a result, organizations are forced to procure more and more megabytes of storage space. This paper focuses on how to expand the storage capacity of a Very Large Database (VLDB) cost-effectively within a Oracle7 data warehouse system by integrating long term archival storage sub-systems with traditional magnetic media. The Oracle architecture described in this paper was based on an actual proof of concept for a customer looking to store archived data on optical disks yet still have access to this data without user intervention. The customer had a requirement to maintain 10 years worth of data on-line. Data less than a year old still had the potential to be updated thus will reside on conventional magnetic disks. Data older than a year will be considered archived and will be placed on optical disks. The ability to archive data to optical disk and still have access to that data provides the system a means to retain large amounts of data that is readily accessible yet significantly reduces the cost of total system storage. Therefore, the cost benefits of archival storage devices can be incorporated into the Oracle storage medium and I/O subsystem without loosing any of the functionality of transaction processing, yet at the same time providing an organization access to all their data.

  6. (reprocessed)CAGE_peaks_annotation - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM...: ftp://ftp.biosciencedbc.jp/archive/fantom5/datafiles/reprocessed/hg38_latest/extra/CAGE_peaks_annotation/ ...e URL: ftp://ftp.biosciencedbc.jp/archive/fantom5/datafiles/reprocessed/mm10_latest/extra/CAGE_peaks_annotat...te History of This Database Site Policy | Contact Us (reprocessed)CAGE_peaks_annotation - FANTOM5 | LSDB Archive ...

  7. (reprocessed)CAGE_peaks_expression - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM...sciencedbc.jp/archive/fantom5/datafiles/reprocessed/hg38_latest/extra/CAGE_peaks_expression/ File size: 3.3 ...tp.biosciencedbc.jp/archive/fantom5/datafiles/reprocessed/mm10_latest/extra/CAGE_peaks_expression/ File size...f This Database Site Policy | Contact Us (reprocessed)CAGE_peaks_expression - FANTOM5 | LSDB Archive ...

  8. Download - fRNAdb | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...Download License Update History of This Database Site Policy | Contact Us Download - fRNAdb | LSDB Archive ...

  9. Download - TogoTV | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ... Download License Update History of This Database Site Policy | Contact Us Download - TogoTV | LSDB Archive ...

  10. Clauser-Horne-Shimony-Holt versus three-party pseudo-telepathy: on the optimal number of samples in device-independent quantum private query

    Science.gov (United States)

    Basak, Jyotirmoy; Maitra, Subhamoy

    2018-04-01

    In device-independent (DI) paradigm, the trustful assumptions over the devices are removed and CHSH test is performed to check the functionality of the devices toward certifying the security of the protocol. The existing DI protocols consider infinite number of samples from theoretical point of view, though this is not practically implementable. For finite sample analysis of the existing DI protocols, we may also consider strategies for checking device independence other than the CHSH test. In this direction, here we present a comparative analysis between CHSH and three-party Pseudo-telepathy game for the quantum private query protocol in DI paradigm that appeared in Maitra et al. (Phys Rev A 95:042344, 2017) very recently.

  11. The CORDEX archive in ESGF: a global archive for regional data

    Science.gov (United States)

    Juckes, Martin; Lautenschlager, Michael; Legutke, Stephanie; Bøssing Christensen, Ole; Kolax, Michael; Denvil, Sébastien

    2013-04-01

    The CORDEX program will produce regional model simulations for all areas of the globe, run by many modelling centres but with a consistent set of experimental parameters. Following the example set with the Coupled Model Inter-comparison Project, Phase 5 (CMIP5) archive of global climate simulations, a federated archive infrastructure will be exploited to support efficient distribution of the data and provide a single catalogue with a flexible search interface. Initial work towards establishing the European component of federated archive for CORDEX using the Earth System Grid Federation (ESGF) software has been started in the FP7 project IS-ENES (InfraStructure for the European Network for Earth System Modelling http://is.enes.org) and will be continued under IS-ENES2 (with additional support for an archive node at the University of Cape Town, S. Africa). The ESGF system allows data held at multiple sites to be accessed by users in a transparent manner. This poster will describe key adaptations of the ESGF CMIP5 infrastructure for CORDEX and some of the data services the system will provide. The vocabularies which underpin the facets of the search interface have been adapted and extended, a strategy for quality control has been developed. For the CMIP5 archive, most modelling centres contributing data also deployed an ESGF archive node. For the CORDEX archive a different approach will be followed because data is expected from a larger number of contributors without the resources needed to run such software. Instead, the CORDEX federated archive will be hosted at a moderate number of institutions with the required resources and expertise.

  12. Trends in monitoring pharmaceuticals and personal-care products in the aquatic environment by use of passive sampling devices

    Science.gov (United States)

    Mills, G.A.; Vrana, B.; Allan, I.; Alvarez, D.A.; Huckins, J.N.; Greenwood, R.

    2007-01-01

    The use of passive sampling in monitoring pharmaceuticals and personal-care products (PPCPs) in the aquatic environment is discussed. The utility of passive sampling methods for monitoring the fraction of heavy metals and the biologically available fraction of non-polar organic priority pollutants is recognized and these technologies are being used in surveys of water quality. These devices are used to measure the dissolved fraction and they can yield information that can be used in the development of risk assessments models. These devices can also be used to locate illegal dumping and to monitor specific sources of input of PPCPs into the environment, or to monitor the effectiveness of water treatment processes in the removal of these compounds from wastewater. These devices can provide representative information at low cost which necessitate a combination of laboratory calibration and field studies for emerging pollutants.

  13. License - dbQSNP | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...escription Download License Update History of This Database Site Policy | Contact Us License - dbQSNP | LSDB Archive ...

  14. License - eSOL | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...iption Download License Update History of This Database Site Policy | Contact Us License - eSOL | LSDB Archive ...

  15. Archiving Websites

    DEFF Research Database (Denmark)

    Brügger, Niels

    This book treats the micro archiving of websites, i.e. archiving by researchers, students or others without special technical knowledge who, using a standard computer, wish to save a website for further study. The phenomenon is discussed from the standpoint that Internet research must be able...

  16. Download - eSOL | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...Database Description Download License Update History of This Database Site Policy | Contact Us Download - eSOL | LSDB Archive ...

  17. (Per)Forming Archival Research Methodologies

    Science.gov (United States)

    Gaillet, Lynee Lewis

    2012-01-01

    This article raises multiple issues associated with archival research methodologies and methods. Based on a survey of recent scholarship and interviews with experienced archival researchers, this overview of the current status of archival research both complicates traditional conceptions of archival investigation and encourages scholars to adopt…

  18. Limitations in the Use of Archived Vent Mussel Samples to Assess Genetic Connectivity Among Seafloor Massive Sulfide Deposits: A Case Study with Implications for Environmental Management

    OpenAIRE

    Boschen, Rachel E.; Rowden, Ashley A.; Clark, Malcolm R.; Gardner, Jonathan P. A.

    2015-01-01

    Genetic connectivity studies can inform the design of mitigation strategies used in environmental management. However, the expense of developing species-specific molecular markers and collecting samples at appropriate spatial and temporal scales can be prohibitive. Using archived material and existing molecular markers may provide a cost-effective way to assess population connectivity. Genetic connectivity studies are increasingly in demand in the deep sea in response to mounting anthropogeni...

  19. CAGE_peaks_annotation - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM...file File name: CAGE_peaks_annotation File URL: ftp://ftp.biosciencedbc.jp/archive/fantom...on Download License Update History of This Database Site Policy | Contact Us CAGE_peaks_annotation - FANTOM5 | LSDB Archive ...

  20. pSort search result - KOME | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...name: kome_psort_search_result.zip File URL: ftp://ftp.biosciencedbc.jp/archive/kome/LATEST/kome_psort_searc...abase Description Download License Update History of This Database Site Policy | Contact Us pSort search result - KOME | LSDB Archive ...

  1. Devices used by automated milking systems are similarly accurate in estimating milk yield and in collecting a representative milk sample compared with devices used by farms with conventional milk recording

    NARCIS (Netherlands)

    Kamphuis, Claudia; Dela Rue, B.; Turner, S.A.; Petch, S.

    2015-01-01

    Information on accuracy of milk-sampling devices used on farms with automated milking systems (AMS) is essential for development of milk recording protocols. The hypotheses of this study were (1) devices used by AMS units are similarly accurate in estimating milk yield and in collecting

  2. Toward Automatic Georeferencing of Archival Aerial Photogrammetric Surveys

    Science.gov (United States)

    Giordano, S.; Le Bris, A.; Mallet, C.

    2018-05-01

    Images from archival aerial photogrammetric surveys are a unique and relatively unexplored means to chronicle 3D land-cover changes over the past 100 years. They provide a relatively dense temporal sampling of the territories with very high spatial resolution. Such time series image analysis is a mandatory baseline for a large variety of long-term environmental monitoring studies. The current bottleneck for accurate comparison between epochs is their fine georeferencing step. No fully automatic method has been proposed yet and existing studies are rather limited in terms of area and number of dates. State-of-the art shows that the major challenge is the identification of ground references: cartographic coordinates and their position in the archival images. This task is manually performed, and extremely time-consuming. This paper proposes to use a photogrammetric approach, and states that the 3D information that can be computed is the key to full automation. Its original idea lies in a 2-step approach: (i) the computation of a coarse absolute image orientation; (ii) the use of the coarse Digital Surface Model (DSM) information for automatic absolute image orientation. It only relies on a recent orthoimage+DSM, used as master reference for all epochs. The coarse orthoimage, compared with such a reference, allows the identification of dense ground references and the coarse DSM provides their position in the archival images. Results on two areas and 5 dates show that this method is compatible with long and dense archival aerial image series. Satisfactory planimetric and altimetric accuracies are reported, with variations depending on the ground sampling distance of the images and the location of the Ground Control Points.

  3. TOWARD AUTOMATIC GEOREFERENCING OF ARCHIVAL AERIAL PHOTOGRAMMETRIC SURVEYS

    Directory of Open Access Journals (Sweden)

    S. Giordano

    2018-05-01

    Full Text Available Images from archival aerial photogrammetric surveys are a unique and relatively unexplored means to chronicle 3D land-cover changes over the past 100 years. They provide a relatively dense temporal sampling of the territories with very high spatial resolution. Such time series image analysis is a mandatory baseline for a large variety of long-term environmental monitoring studies. The current bottleneck for accurate comparison between epochs is their fine georeferencing step. No fully automatic method has been proposed yet and existing studies are rather limited in terms of area and number of dates. State-of-the art shows that the major challenge is the identification of ground references: cartographic coordinates and their position in the archival images. This task is manually performed, and extremely time-consuming. This paper proposes to use a photogrammetric approach, and states that the 3D information that can be computed is the key to full automation. Its original idea lies in a 2-step approach: (i the computation of a coarse absolute image orientation; (ii the use of the coarse Digital Surface Model (DSM information for automatic absolute image orientation. It only relies on a recent orthoimage+DSM, used as master reference for all epochs. The coarse orthoimage, compared with such a reference, allows the identification of dense ground references and the coarse DSM provides their position in the archival images. Results on two areas and 5 dates show that this method is compatible with long and dense archival aerial image series. Satisfactory planimetric and altimetric accuracies are reported, with variations depending on the ground sampling distance of the images and the location of the Ground Control Points.

  4. Transnational archives: the Canadian case

    Directory of Open Access Journals (Sweden)

    Julia Creet

    2011-05-01

    Full Text Available This paper is a brief overview of the concept of the transnational archive as a counterpoint to the idea that a national archive is necessarily a locus of a static idea of nation. The Canadian national archives is used as a case study of an archives that was transnational in its inception, and one that has continued to change in its mandate and materials as a response to patterns in migration and changing notions of multiculturalism as a Canadian federal policy. It introduces the most recent formation of the transnational archive and its denizens: the genealogical archive inhabited by family historians.

  5. The Snowden Archive-in-a-Box: A year of travelling experiments in outreach and education

    Directory of Open Access Journals (Sweden)

    Evan Light

    2016-11-01

    Full Text Available The Snowden Archive-in-a-Box is an offline wireless network and web server providing private access to a replica of the Snowden Digital Surveillance Archive. The online version is hosted by Canadian Journalists for Free Expression. A work-in-development since April 2015, the Archive-in-a-Box is both a research tool and a tool for public education on data surveillance. The original version is powered with battery packs and housed in a 1960s spy style briefcase. When it is turned on, anybody in the vicinity can access the archive by connecting their wireless device to the Snowden Archive WiFi network and browsing to a website. Open the briefcase up and one finds a wood panel with a flatscreen inset, playing back the IP traffic of the archive's current users. Thus, while an audience such as a class of students or workshop group can access the Snowden documents and learn about mass surveillance from primary materials, they are also shown what data surveillance ‘looks like’. This Commentary explores my experiences during the first year of the Snowden Archive-in-a-Box. I examine my experiences as an international traveller carrying a suspicious briefcase of Top Secret materials and this project's reception by certain audiences. The project is still a prototype, yet it is quickly gathering a following and a number of permanent installations around the world. What could this mean for the future of surveillance education and leaks-enabled research?

  6. Analysis list - ChIP-Atlas | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...://ftp.biosciencedbc.jp/archive/chip-atlas/LATEST/chip_atlas_analysis_list.zip File size: 44.8 KB Simple sea...e class. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Analysis list - ChIP-Atlas | LSDB Archive ...

  7. A method to evaluate genome-wide methylation in archival formalin-fixed, paraffin-embedded ovarian epithelial cells.

    Directory of Open Access Journals (Sweden)

    Qiling Li

    Full Text Available The use of DNA from archival formalin and paraffin embedded (FFPE tissue for genetic and epigenetic analyses may be problematic, since the DNA is often degraded and only limited amounts may be available. Thus, it is currently not known whether genome-wide methylation can be reliably assessed in DNA from archival FFPE tissue.Ovarian tissues, which were obtained and formalin-fixed and paraffin-embedded in either 1999 or 2011, were sectioned and stained with hematoxylin-eosin (H&E.Epithelial cells were captured by laser micro dissection, and their DNA subjected to whole genomic bisulfite conversion, whole genomic polymerase chain reaction (PCR amplification, and purification. Sequencing and software analyses were performed to identify the extent of genomic methylation. We observed that 31.7% of sequence reads from the DNA in the 1999 archival FFPE tissue, and 70.6% of the reads from the 2011 sample, could be matched with the genome. Methylation rates of CpG on the Watson and Crick strands were 32.2% and 45.5%, respectively, in the 1999 sample, and 65.1% and 42.7% in the 2011 sample.We have developed an efficient method that allows DNA methylation to be assessed in archival FFPE tissue samples.

  8. ArchiveDB—Scientific and technical data archive for Wendelstein 7-X

    International Nuclear Information System (INIS)

    Hennig, Christine; Maier, Josef; Grün, Martin; Krom, Jon; Blum, Torsten; Grahl, Michael; Heimann, Peter; Riemann, Heike; Laqua, Heike; Lewerentz, Marc; Spring, Anett; Werner, Andreas

    2016-01-01

    Highlights: • ArchiveDB archives all scientific and technical data of Wendelstein. • Primary index is the measured absolute time. • Continuously arising data is chunked in time for storage. • The Big Data Lambda Architecture pattern is applied. • The system is in place since a decade and a major change of underlying technology has been mastered. - Abstract: ArchiveDB is the data archive for all scientific and technical data collected at the Wendelstein 7-X project. It is a distributed system allowing continuous data archival. ArchiveDB has demanding requirements regarding performance efficiency (storage performance of 30 GB/s during experiments, expected storage amount of 1.4 PB/year), reliability (availability of 364 days/year), maintainability (testability) and portability (including change of hardware and software). Data acquisition with continuous operation and high time resolutions (up to nanoseconds scale) for physics data is supported as well as long-term recording up to 24 h/7 days for operational data (∼1 Hz rate). Moreover, all results of data analysis are stored in the archive. Another challenge, uniform retrieval of measured and analyzed data, allowing time and structure information as selection criteria, is mastered as well. The key concepts of data storage and retrieval are: (1) partitioning of incoming data in groups and stream, (2) chunking of data in boxes of manageable size covering a finite time period, and (3) indexing of data using absolute time as ordering and indexing criteria. Continuous operation of the ArchiveDB software and hardware for various systems and components relevant to Wendelstein 7-X has been done successfully for several years, thus, showing that the key requirements are satisfied. The overall data amount so far has reached 7 Terabyte over 9 years of data taking. Round-the-clock operation of the archive is in place since 5 years. Initial plasma operation OP1.1 of Wendelstein 7-X has been supported with no downtime

  9. ArchiveDB—Scientific and technical data archive for Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Hennig, Christine, E-mail: Christine.Hennig@ipp.mpg.de [Max Planck Institute for Plasma Physics, Wendelsteinstraße 1, 17491 Greifswald (Germany); Maier, Josef, E-mail: Josef.Maier@ipp.mpg.de [Max Planck Institute for Plasma Physics, Boltzmannstraße 2, 85748 Garching (Germany); Grün, Martin, E-mail: Martin.Gruen@ipp.mpg.de [FERCHAU Engineering GmbH, Steinmüllerallee 2, 51643 Gummersbach (Germany); Krom, Jon, E-mail: Jon.Krom@ipp.mpg.de [Max Planck Institute for Plasma Physics, Wendelsteinstraße 1, 17491 Greifswald (Germany); Blum, Torsten, E-mail: Torsten.Bluhm@ipp.mpg.de [Max Planck Institute for Plasma Physics, Wendelsteinstraße 1, 17491 Greifswald (Germany); Grahl, Michael, E-mail: Michael.Grahl@ipp.mpg.dem [Max Planck Institute for Plasma Physics, Wendelsteinstraße 1, 17491 Greifswald (Germany); Heimann, Peter, E-mail: Peter.Heimann@ipp.mpg.de [Max Planck Institute for Plasma Physics, Boltzmannstraße 2, 85748 Garching (Germany); Riemann, Heike, E-mail: Heike.Riemann@ipp.mpg.de [Max Planck Institute for Plasma Physics, Wendelsteinstraße 1, 17491 Greifswald (Germany); Laqua, Heike, E-mail: Heike.Laqua@ipp.mpg.de [Max Planck Institute for Plasma Physics, Wendelsteinstraße 1, 17491 Greifswald (Germany); Lewerentz, Marc, E-mail: Marc.Lewerentz@ipp.mpg.de [Max Planck Institute for Plasma Physics, Wendelsteinstraße 1, 17491 Greifswald (Germany); Spring, Anett, E-mail: Anett.Spring@ipp.mpg.de [Max Planck Institute for Plasma Physics, Wendelsteinstraße 1, 17491 Greifswald (Germany); Werner, Andreas, E-mail: Andreas.Werner@ipp.mpg.de [Max Planck Institute for Plasma Physics, Wendelsteinstraße 1, 17491 Greifswald (Germany)

    2016-11-15

    Highlights: • ArchiveDB archives all scientific and technical data of Wendelstein. • Primary index is the measured absolute time. • Continuously arising data is chunked in time for storage. • The Big Data Lambda Architecture pattern is applied. • The system is in place since a decade and a major change of underlying technology has been mastered. - Abstract: ArchiveDB is the data archive for all scientific and technical data collected at the Wendelstein 7-X project. It is a distributed system allowing continuous data archival. ArchiveDB has demanding requirements regarding performance efficiency (storage performance of 30 GB/s during experiments, expected storage amount of 1.4 PB/year), reliability (availability of 364 days/year), maintainability (testability) and portability (including change of hardware and software). Data acquisition with continuous operation and high time resolutions (up to nanoseconds scale) for physics data is supported as well as long-term recording up to 24 h/7 days for operational data (∼1 Hz rate). Moreover, all results of data analysis are stored in the archive. Another challenge, uniform retrieval of measured and analyzed data, allowing time and structure information as selection criteria, is mastered as well. The key concepts of data storage and retrieval are: (1) partitioning of incoming data in groups and stream, (2) chunking of data in boxes of manageable size covering a finite time period, and (3) indexing of data using absolute time as ordering and indexing criteria. Continuous operation of the ArchiveDB software and hardware for various systems and components relevant to Wendelstein 7-X has been done successfully for several years, thus, showing that the key requirements are satisfied. The overall data amount so far has reached 7 Terabyte over 9 years of data taking. Round-the-clock operation of the archive is in place since 5 years. Initial plasma operation OP1.1 of Wendelstein 7-X has been supported with no downtime

  10. License - Q-TARO | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...thout notice. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - Q-TARO | LSDB Archive ...

  11. Download - GenLibi | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...access [here]. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Download - GenLibi | LSDB Archive ...

  12. An Efficient, Robust, and Inexpensive Grinding Device for Herbal Samples like Cinchona Bark.

    Science.gov (United States)

    Hansen, Steen Honoré; Holmfred, Else; Cornett, Claus; Maldonado, Carla; Rønsted, Nina

    2015-01-01

    An effective, robust, and inexpensive grinding device for the grinding of herb samples like bark and roots was developed by rebuilding a commercially available coffee grinder. The grinder was constructed to be able to provide various particle sizes, to be easy to clean, and to have a minimum of dead volume. The recovery of the sample when grinding as little as 50 mg of crude Cinchona bark was about 60%. Grinding is performed in seconds with no rise in temperature, and the grinder is easily disassembled to be cleaned. The influence of the particle size of the obtained powders on the recovery of analytes in extracts of Cinchona bark was investigated using HPLC.

  13. GPCR Interaction - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us GRI...ed information (disease etc.). Data file File name: gripdb_main.zip File URL: ftp://ftp.biosciencedbc.jp/archive/gripdb/LATEST/gri...godb.biosciencedbc.jp/togodb/view/gripdb_main#en Data acquisition method PDB, Refseq Data analysis method - ...Number of data entries 409 entries Data item Description GRIP ID Interaction ID Main Title Interaction title...tabase Database Description Download License Update History of This Database Site Policy | Contact Us GPCR Interaction - GRIPDB | LSDB Archive ...

  14. License - RGP gmap | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...nged without notice. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - RGP gmap | LSDB Archive ...

  15. Download - Plabrain DB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us Plabrain...s Database Database Description Download License Update History of This Database Site Policy | Contact Us Download - Plabrain DB | LSDB Archive ...

  16. Gaia Data Release 1. The archive visualisation service

    Science.gov (United States)

    Moitinho, A.; Krone-Martins, A.; Savietto, H.; Barros, M.; Barata, C.; Falcão, A. J.; Fernandes, T.; Alves, J.; Silva, A. F.; Gomes, M.; Bakker, J.; Brown, A. G. A.; González-Núñez, J.; Gracia-Abril, G.; Gutiérrez-Sánchez, R.; Hernández, J.; Jordan, S.; Luri, X.; Merin, B.; Mignard, F.; Mora, A.; Navarro, V.; O'Mullane, W.; Sagristà Sellés, T.; Salgado, J.; Segovia, J. C.; Utrilla, E.; Arenou, F.; de Bruijne, J. H. J.; Jansen, F.; McCaughrean, M.; O'Flaherty, K. S.; Taylor, M. B.; Vallenari, A.

    2017-09-01

    Context. The first Gaia data release (DR1) delivered a catalogue of astrometry and photometry for over a billion astronomical sources. Within the panoplyof methods used for data exploration, visualisation is often the starting point and even the guiding reference for scientific thought. However, this is a volume of data that cannot be efficiently explored using traditional tools, techniques, and habits. Aims: We aim to provide a global visual exploration service for the Gaia archive, something that is not possible out of the box for most people. The service has two main goals. The first is to provide a software platform for interactive visual exploration of the archive contents, using common personal computers and mobile devices available to most users. The second aim is to produce intelligible and appealing visual representations of the enormous information content of the archive. Methods: The interactive exploration service follows a client-server design. The server runs close to the data, at the archive, and is responsible for hiding as far as possible the complexity and volume of the Gaia data from the client. This is achieved by serving visual detail on demand. Levels of detail are pre-computed using data aggregation and subsampling techniques. For DR1, the client is a web application that provides an interactive multi-panel visualisation workspace as well as a graphical user interface. Results: The Gaia archive Visualisation Service offers a web-based multi-panel interactive visualisation desktop in a browser tab. It currently provides highly configurable 1D histograms and 2D scatter plots of Gaia DR1 and the Tycho-Gaia Astrometric Solution (TGAS) with linked views. An innovative feature is the creation of ADQL queries from visually defined regions in plots. These visual queries are ready for use in the Gaia Archive Search/data retrieval service. In addition, regions around user-selected objects can be further examined with automatically generated SIMBAD

  17. Development of an automatic sampling device for the continuous measurement of atmospheric carbonyls compounds

    International Nuclear Information System (INIS)

    Perraud, V.

    2007-12-01

    Two sampling strategies were studied to develop an automatic instrument for the continuous measurement of atmospheric carbonyl compounds. Because of its specificity towards carbonyls compounds, sampling by using a transfer of gaseous phase in a liquid phase associated with a simultaneous chemical derivatization of the trapped compounds was first studied. However, this method do not allow a quantitative sampling of all studied carbonyl compounds, nor a continuous measurement in the field. To overcome the difficulties, a second strategy was investigated: the cryogenic adsorption onto solid adsorbent followed by thermodesorption and a direct analysis by GC/MS. Collection efficiency using different solid adsorbents was found greater than 95% for carbonyl compounds consisting of 1 to 7 carbons. This work is a successful first step towards the realization of the automatic sampling device for a continuous measurement of atmospheric carbonyls compounds. (author)

  18. National Archives Catalog and API

    Data.gov (United States)

    National Archives and Records Administration — The National Archives Catalog is the online catalog of NARA's nationwide holdings in the Washington, DC area, Regional Archives, and Presidential Libraries.

  19. Lessons learned from planetary science archiving

    Science.gov (United States)

    Zender, J.; Grayzeck, E.

    2006-01-01

    The need for scientific archiving of past, current, and future planetary scientific missions, laboratory data, and modeling efforts is indisputable. To quote from a message by G. Santayama carved over the entrance of the US Archive in Washington DC “Those who can not remember the past are doomed to repeat it.” The design, implementation, maintenance, and validation of planetary science archives are however disputed by the involved parties. The inclusion of the archives into the scientific heritage is problematic. For example, there is the imbalance between space agency requirements and institutional and national interests. The disparity of long-term archive requirements and immediate data analysis requests are significant. The discrepancy between the space missions archive budget and the effort required to design and build the data archive is large. An imbalance exists between new instrument development and existing, well-proven archive standards. The authors present their view on the problems and risk areas in the archiving concepts based on their experience acquired within NASA’s Planetary Data System (PDS) and ESA’s Planetary Science Archive (PSA). Individual risks and potential problem areas are discussed based on a model derived from a system analysis done upfront. The major risk for a planetary mission science archive is seen in the combination of minimal involvement by Mission Scientists and inadequate funding. The authors outline how the risks can be reduced. The paper ends with the authors view on future planetary archive implementations including the archive interoperability aspect.

  20. Resources for the User's Guide to the Royal Hetman's Archives in archives and library collections

    Directory of Open Access Journals (Sweden)

    Krzysztof Syta

    2012-12-01

    Full Text Available This article is an overview of archival collections with provenance of hetman's archives, but physically separated into collections in archives and libraries across Poland (Kraków, Kórnik, Łódź, Poznań, Warszawa and also Ukraine (Kiev, Lviv. Research, which later became an inspiration for this overview, has been conducted mainly in the early 90s. In the light of the above, this article does not claim to be called a "guide" to the royalhetmans' archives of the sixteenth through to the eighteenth century, but it could be viewed as an outline of such archival finding aid. This overview focuses on characteristics of different types of archival material, which author considered integrally connected to holding of an office of hetman, i.e.: personal, administrative and military, judiciary, financial, and also correspondence. Qualification criteria may raise some concerns, because selection of archives is subjective by nature, but also because in the discussed time period there was social consensus on the fact that one's private life and public sphere would overlap. Most of the archival materials used in this study comes from the hetman's archives of the eighteenth century (Jan Clement Branicki's; Franciszek Ksawery Branicki's; Stanisław Mateusz, Wacław, Seweryn Rzewuski's and Adam Mikołaj Sieniawski's. Eighteen century is considered to be the peak of development of private archives, which - without a doubt - had great impact on the preservation of hetman's archives of that period. Moreover, the fact that there is significantly larger collection of hetman's archives of that period, compared to previous two centuries, is the result of the hetman's office having a special place within the political system of the Polish-Lithuanian Commonwealth.

  1. License - fRNAdb | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...be changed without notice. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - fRNAdb | LSDB Archive ...

  2. License - AT Atlas | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ... might be changed without notice. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - AT Atlas | LSDB Archive ...

  3. License - TP Atlas | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ... might be changed without notice. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - TP Atlas | LSDB Archive ...

  4. Archives: Ethiopian Veterinary Journal

    African Journals Online (AJOL)

    Items 1 - 16 of 16 ... Archives: Ethiopian Veterinary Journal. Journal Home > Archives: Ethiopian Veterinary Journal. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 16 of 16 Items ...

  5. Archives: Nigerian Veterinary Journal

    African Journals Online (AJOL)

    Items 1 - 49 of 49 ... Archives: Nigerian Veterinary Journal. Journal Home > Archives: Nigerian Veterinary Journal. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 49 of 49 Items ...

  6. Archives: Continuing Medical Education

    African Journals Online (AJOL)

    Items 51 - 88 of 88 ... Archives: Continuing Medical Education. Journal Home > Archives: Continuing Medical Education. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 51 - 88 of 88 ...

  7. Archives: African Studies Monographs

    African Journals Online (AJOL)

    Archives: African Studies Monographs. Journal Home > Archives: African Studies Monographs. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 5 of 5 Items. 2007. Vol 8 (2007) ...

  8. Theoretical currents of Archival Science

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Ávila Araújo

    2013-08-01

    Full Text Available Archival Science was formed, as a scientific discipline, in the late nineteenth century, from the consolidation of a custody and heritage model. In the twentieth century, several theories have been developed, systematized in this article in four axes. As a result, Archival Science has expanded its scope of studies. As a result of this expansion, there are contemporary perspectives with systemic models, covering different types of archives, concerned with the sociocultural context of the archives, and also insering digital technologies in the practice of archives.

  9. GPCR Mutation information - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us GRI...s and exposed in molecular surface. Data file File name: gripdb_mutation_info.zip File URL: ftp://ftp.biosciencedbc.jp/archive/gri...pdb/LATEST/gripdb_mutation_info.zip File size: 766 bytes Si...mple search URL http://togodb.biosciencedbc.jp/togodb/view/gripdb_mutation_info#en Data acquisition method P... Site Policy | Contact Us GPCR Mutation information - GRIPDB | LSDB Archive ...

  10. Archives: Malawi Medical Journal

    African Journals Online (AJOL)

    Items 1 - 50 of 72 ... Archives: Malawi Medical Journal. Journal Home > Archives: Malawi Medical Journal. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 50 of 72 Items, 1 2 > >> ...

  11. Archives: African Health Sciences

    African Journals Online (AJOL)

    Items 1 - 50 of 67 ... Archives: African Health Sciences. Journal Home > Archives: African Health Sciences. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 50 of 67 Items, 1 2 > >> ...

  12. Archives: Health SA Gesondheid

    African Journals Online (AJOL)

    Items 1 - 42 of 42 ... Archives: Health SA Gesondheid. Journal Home > Archives: Health SA Gesondheid. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 42 of 42 Items. 2018 ...

  13. Download - Open TG-GATEs | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...Download License Update History of This Database Site Policy | Contact Us Download - Open TG-GATEs | LSDB Archive ...

  14. FTP archives for physics

    International Nuclear Information System (INIS)

    Trunec, D.; Brablec, A.; Kapicka, V.

    1995-01-01

    We have established archives for programs, data, papers etc. in physics (mainly for plasma physics). The archives are located at computer ftp.muni.cz in the directory pub/muni.cz/physics. These archives can be reached by anonymous FTP or by gopher server gopher.muni.cz (147.251.4.33). At the present time, programs for PC, cross sections for electrons, swarm parameters and rate constants stored are in the archives. We would like to collect the programs for calculations in physics (mainly for PC). We suppose that each program should have a testing example and some description. We would also like to collect physical constants and experimental or theoretical data (e.g. cross sections, swarm parameters and rate constants), which are important for other calculation or for comparison with the results of others studies. Interested scholars are invited to sent us their programs, data, preprints and reports for these archives. All files in the archives are in public domain and can be obtained using computer network Internet

  15. Download - tRNADB-CE | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us tRNAD...f This Database Site Policy | Contact Us Download - tRNADB-CE | LSDB Archive ...

  16. Archives: Mizan Law Review

    African Journals Online (AJOL)

    Items 1 - 21 of 21 ... Archives: Mizan Law Review. Journal Home > Archives: Mizan Law Review. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 21 of 21 Items. 2017. Vol 11, No 2 ...

  17. Update History of This Database - dbQSNP | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us dbQSNP Update History of This Database Date Update contents 2017/02/16 dbQSNP English archiv...e Description Download License Update History of This Database Site Policy | Contact Us Update History of This Database - dbQSNP | LSDB Archive ... ...e site is opened. 2002/10/23 dbQSNP (http://qsnp.gen.kyushu-u.ac.jp/) is opened. About This Database Databas

  18. Microbial profiling of cpn60 universal target sequences in artificial mixtures of vaginal bacteria sampled by nylon swabs or self-sampling devices under different storage conditions.

    Science.gov (United States)

    Schellenberg, John J; Oh, Angela Yena; Hill, Janet E

    2017-05-01

    The vaginal microbiome is increasingly characterized by deep sequencing of universal genes. However, there are relatively few studies of how different specimen collection and sample storage and processing influence these molecular profiles. Here, we evaluate molecular microbial community profiles of samples collected using the HerSwab™ self-sampling device, compared to nylon swabs and under different storage conditions. In order to minimize technical variation, mixtures of 11 common vaginal bacteria in simulated vaginal fluid medium were sampled and DNA extracts prepared for massively parallel sequencing of the cpn60 universal target (UT). Three artificial mixtures imitating commonly observed vaginal microbiome profiles were easily distinguished and proportion of sequence reads correlated with the estimated proportion of the organism added to the artificial mixtures. Our results indicate that cpn60 UT amplicon sequencing quantifies the proportional abundance of member organisms in these artificial communities regardless of swab type or storage conditions, although some significant differences were observed between samples that were stored frozen and thawed prior to DNA extraction, compared to extractions from samples stored at room temperature for up to 7days. Our results indicate that an on-the-market device developed for infectious disease diagnostics may be appropriate for vaginal microbiome profiling, an approach that is increasingly facilitated by rapidly dropping deep sequencing costs. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Fermilab History and Archives Project | Home

    Science.gov (United States)

    Special Events Early Users Meetings (1979 - 1989) The Tevatron Natural History Discoveries Technology Site Fermilab History and Archives Project Fermilab History and Archives Project Fermi National Accelerator Laboratory Home About the Archives History & Archives Online Request Contact Us Site Index

  20. Update History of This Database - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available CAGE TSS aggregation 」 「 CAGE peaks 」 2015/12/07 FANTOM5 archive site is opened. (Archive V1) 2014/03/27 FANTOM5 ( http://fantom...switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM...5 Update History of This Database Date Update contents 2017/03/14 FANTOM5 English arch...escription Download License Update History of This Database Site Policy | Contact Us Update History of This Database - FANTOM5 | LSDB Archive ...

  1. Use of a dry-plasma collection device to overcome problems with storage and transportation of blood samples for epidemiology studies in developing countries.

    Science.gov (United States)

    Nurgalieva, Z Z; Almuchambetova, R; Machmudova, A; Kapsultanova, D; Osato, M S; Peacock, J; Zoltek, R P; Marchildon, P A; Graham, D Y; Zhangabylov, A

    2000-11-01

    Studies are difficult in areas lacking modern facilities due to the inability to reliably collect, store, and ship samples. Thus, we sought to evaluate the use of a dry plasma collection device for seroepidemiology studies. Plasma was obtained by fingerstick using a commercial dry plasma collection device (Chemcard Plasma Collection Device) and serum (venipuncture) from individuals in Kazakhstan. Plasma samples were air dried for 15 min and then stored desiccated in foil zip-lock pouches at 4 to 6 degrees C and subsequently shipped to the United States by air at ambient temperature. Serum samples remained frozen at -20 degrees C until assayed. Helicobacter pylori status was determined by enzyme-linked immunosorbent assay (HM-CAP EIA) for the dry plasma and the serum samples. The results were concordant in 250 of the 289 cases (86.5%). In 25 cases (8.6%), the dry plasma samples gave indeterminate results and could not be retested because only one sample was collected. Five serum samples were positive, and the corresponding dry plasma samples were negative; one serum sample was negative, and the corresponding plasma sample was positive. The relative sensitivity and specificity of the Chemcard samples to serum were 97.6 and 97.9%, respectively, excluding those with indeterminate results. Repeated freeze-thawing had no adverse effect on the accuracy of the test. We found the dry plasma collection device to provide an accurate and practical alternative to serum when venipuncture may be difficult or inconvenient and sample storage and handling present difficulties, especially for seroepidemiologic studies in rural areas or developing countries and where freeze-thawing may be unavoidable.

  2. Sampling device for in vivo sampling of liquids from the gastrointestinal tract, process for the production thereof and mould or mask for use in the production process

    NARCIS (Netherlands)

    Sprenkels, A.J.; Jenneboer, Antonius J.S.M.; Venema, Konraad; van den Berg, Albert; de Vos, Willem M.

    2006-01-01

    The present invention relates to a sampling device suitable for in vivo sampling of liquid(s) from the gastro-intestinal tract, comprising a body, the body comprising a channel and an opening for entrance of the liquid(s) at one end of the channel, and a cover bonded to at least part of the body and

  3. Data archiving in experimental physics

    International Nuclear Information System (INIS)

    Dalesio, L.R.; Watson, W. III; Bickley, M.; Clausen, M.

    1998-01-01

    In experimental physics, data is archived from a wide variety of sources and used for a wide variety of purposes. In each of these environments, trade-offs are made between data storage rate, data availability, and retrieval rate. This paper presents archive alternatives in EPICS, the overall archiver design and details on the data collection and retrieval requirements, performance studies, design choices, design alternatives, and measurements made on the beta version of the archiver

  4. Update History of This Database - DMPD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us DMPD Update History of This Database Date Update contents 2010/03/29 DMPD English archive si....jp/macrophage/ ) is released. About This Database Database Description Download License Update History of Thi...s Database Site Policy | Contact Us Update History of This Database - DMPD | LSDB Archive ...

  5. Occurrence of contaminants of emerging concern along the California coast (2009-10) using passive sampling devices

    Science.gov (United States)

    Alvarez, David A.; Maruya, Keith A.; Dodder, Nathan G.; Lao, Wenjian; Furlong, Edward T.; Smalling, Kelly L.

    2014-01-01

    Three passive sampling devices (PSDs), polar organic chemical integrative samplers (POCIS), polyethylene devices (PEDs), and solid-phase microextraction (SPME) samplers were used to sample a diverse set of chemicals in the coastal waters of San Francisco Bay and the Southern California Bight. Seventy one chemicals (including fragrances, phosphate flame retardants, pharmaceuticals, PAHs, PCBs, PBDEs, and pesticides) were measured in at least 50% of the sites. The chemical profile from the San Francisco Bay sites was distinct from profiles from the sites in the Southern California Bight. This distinction was not due to a single compound or class, but by the relative abundances/concentrations of the chemicals. Comparing the PSDs to mussel (Mytilus spp.) tissues, a positive correlation exists for the 25 and 26 chemicals in common for the PEDs and SPME, respectively. Diphenhydramine was the only common chemical out of 40 analyzed in both POCIS and tissues detected at a common site.

  6. The mycobiota associated with paper archives and their potential control

    Directory of Open Access Journals (Sweden)

    SAIFELDIN A. F. EL-NAGERABI

    2014-07-01

    Full Text Available El-Nagerabi SAF, Elshafie AE, Al-Hinai UA. 2014. The mycobiota associated with paper archives and their potential control. Nusantara Bioscience 6: 19-25. Historical collections kept in archives and libraries represent a cultural and artistic heritage of innumerable value. Recently in Oman, more than seventy thousand documents were collected from different countries and displayed as archives showed evident sign of mold contamination. The objectives of the present study were to screen these archives for mold invasion and a test for the effective control measure. For this, 102 samples were collected from documents of different sources and incubated on potato dextrose agar (PDA at ambient temperature (25○C±2. The isolated fungi were identified microscopically and confirmed with DNA extraction, PCR and DNA sequencing. Twenty-two fungal species belonging to 11 genera were recovered. The genus Penicillium (46.8% was the most prevalent, followed by Aspergillus (30.7%, Cladosporium (7%, Rhizopus (4%, and Chaetomium (3.5% whereas the remaining 6 genera represent only 8%. Eleven species were previously reported from similar substrates, whereas 11 species and one genus are new records for the mycoflora of archives. Sodium hypochlorite at 0.3-5.2% completely inhibited the fungal growth of the 10 tested fungal isolates with minimum inhibition concentration at 0.7%. Fumigation of books with 0.7-5.2% sodium hypochlorite completely inhibited all fungi without evident damage of the documents or ink discoloration. Therefore, sodium hypochlorite can be recommended as effective and eco-friendly disinfectant for archives comparable to other hazardous chemicals.

  7. Ethics and Truth in Archival Research

    Science.gov (United States)

    Tesar, Marek

    2015-01-01

    The complexities of the ethics and truth in archival research are often unrecognised or invisible in educational research. This paper complicates the process of collecting data in the archives, as it problematises notions of ethics and truth in the archives. The archival research took place in the former Czechoslovakia and its turbulent political…

  8. Proteomic workflow for analysis of archival formalin-fixed and paraffin-embedded clinical samples to a depth of 10 000 proteins.

    Science.gov (United States)

    Wiśniewski, Jacek R; Duś, Kamila; Mann, Matthias

    2013-04-01

    Archival formalin-fixed and paraffin-embedded clinical samples represent a very diverse source of material for proteomic investigation of diseases, often with follow-up patient information. Here, we describe an analytical workflow for analysis of laser-capture microdissected formalin-fixed and paraffin-embedded samples that allows studying proteomes to a depth of 10 000 proteins per sample. The workflow involves lysis of tissue in SDS-containing buffer, detergent removal, and consecutive digestion of the proteins with two enzymes by the multienzyme digestion filter-aided sample preparation method. Resulting peptides are fractionated by pipette-tip based strong anion exchange into six fractions and analyzed by LC-MS/MS on a bench top quadrupole Orbitrap mass spectrometer. Analysis of the data using the MaxQuant software resulted in the identification of 9502 ± 28 protein groups per a 110 nL sample of microdissected cells from human colonic adenoma. This depth of proteome analysis enables systemic insights into the organization of the adenoma cells and an estimation of the abundances of known biomarkers. It also allows the identification of proteins expressed from tumor suppressors, oncogenes, and other key players in the development and progression of the colorectal cancer. Our proteomic platform can be used for quantitative comparisons between samples representing different stages of diseases and thus can be applied to the discovery of biomarkers or drug targets. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Update History of This Database - SAHG | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us SAHG Update History of This Database Date Update contents 2016/05/09 SAHG English archive si...te is opened. 2009/10 SAHG ( http://bird.cbrc.jp/sahg ) is opened. About This Database Database Description ...Download License Update History of This Database Site Policy | Contact Us Update History of This Database - SAHG | LSDB Archive ...

  10. Update History of This Database - RMOS | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us RMOS Update History of This Database Date Update contents 2015/10/27 RMOS English archive si...12 RMOS (http://cdna01.dna.affrc.go.jp/RMOS/) is opened. About This Database Database Description Download License Update Hi...story of This Database Site Policy | Contact Us Update History of This Database - RMOS | LSDB Archive ...

  11. On the use of ultracentrifugal devices for routine sample preparation in biomolecular magic-angle-spinning NMR.

    Science.gov (United States)

    Mandal, Abhishek; Boatz, Jennifer C; Wheeler, Travis B; van der Wel, Patrick C A

    2017-03-01

    A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation.

  12. On the use of ultracentrifugal devices for routine sample preparation in biomolecular magic-angle-spinning NMR

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Abhishek; Boatz, Jennifer C. [University of Pittsburgh School of Medicine, Department of Structural Biology (United States); Wheeler, Travis B. [University of Pittsburgh School of Medicine, Department of Cell Biology (United States); Wel, Patrick C. A. van der, E-mail: vanderwel@pitt.edu [University of Pittsburgh School of Medicine, Department of Structural Biology (United States)

    2017-03-15

    A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation.

  13. A MySQL Based EPICS Archiver

    International Nuclear Information System (INIS)

    Slominski, Christopher

    2009-01-01

    Archiving a large fraction of the EPICS signals within the Jefferson Lab (JLAB) Accelerator control system is vital for postmortem and real-time analysis of the accelerator performance. This analysis is performed on a daily basis by scientists, operators, engineers, technicians, and software developers. Archiving poses unique challenges due to the magnitude of the control system. A MySQL Archiving system (Mya) was developed to scale to the needs of the control system; currently archiving 58,000 EPICS variables, updating at a rate of 11,000 events per second. In addition to the large collection rate, retrieval of the archived data must also be fast and robust. Archived data retrieval clients obtain data at a rate over 100,000 data points per second. Managing the data in a relational database provides a number of benefits. This paper describes an archiving solution that uses an open source database and standard off the shelf hardware to reach high performance archiving needs. Mya has been in production at Jefferson Lab since February of 2007.

  14. A MySQL Based EPICS Archiver

    Energy Technology Data Exchange (ETDEWEB)

    Christopher Slominski

    2009-10-01

    Archiving a large fraction of the EPICS signals within the Jefferson Lab (JLAB) Accelerator control system is vital for postmortem and real-time analysis of the accelerator performance. This analysis is performed on a daily basis by scientists, operators, engineers, technicians, and software developers. Archiving poses unique challenges due to the magnitude of the control system. A MySQL Archiving system (Mya) was developed to scale to the needs of the control system; currently archiving 58,000 EPICS variables, updating at a rate of 11,000 events per second. In addition to the large collection rate, retrieval of the archived data must also be fast and robust. Archived data retrieval clients obtain data at a rate over 100,000 data points per second. Managing the data in a relational database provides a number of benefits. This paper describes an archiving solution that uses an open source database and standard off the shelf hardware to reach high performance archiving needs. Mya has been in production at Jefferson Lab since February of 2007.

  15. License - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM....0 International . If you use data from this database, please be sure attribute this database as follows: FANTOM...se Database Description Download License Update History of This Database Site Policy | Contact Us License - FANTOM5 | LSDB Archive ...

  16. License - Trypanosomes Database | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us Trypanoso... Attribution-Share Alike 2.1 Japan . If you use data from this database, please be sure attribute this database as follows: Trypanoso...nse Update History of This Database Site Policy | Contact Us License - Trypanosomes Database | LSDB Archive ...

  17. Long-Term Persistence of Pesticides and TPs in Archived Agricultural Soil Samples and Comparison with Pesticide Application.

    Science.gov (United States)

    Chiaia-Hernandez, Aurea C; Keller, Armin; Wächter, Daniel; Steinlin, Christine; Camenzuli, Louise; Hollender, Juliane; Krauss, Martin

    2017-09-19

    For polar and more degradable pesticides, not many data on long-term persistence in soil under field conditions and real application practices exist. To assess the persistence of pesticides in soil, a multiple-compound screening method (log K ow 1.7-5.5) was developed based on pressurized liquid extraction, QuEChERS and LC-HRMS. The method was applied to study 80 polar pesticides and >90 transformation products (TPs) in archived topsoil samples from the Swiss Soil Monitoring Network (NABO) from 1995 to 2008 with known pesticide application patterns. The results reveal large variations between crop type and field sites. For the majority of the sites 10-15 pesticides were identified with a detection rate of 45% at concentrations between 1 and 330 μg/kg dw in soil. Furthermore, TPs were detected in 47% of the cases where the "parent-compound" was applied. Overall, residues of about 80% of all applied pesticides could be detected with half of these found as TPs with a persistence of more than a decade.

  18. Online Archives

    Directory of Open Access Journals (Sweden)

    Julian D. Richards

    2004-01-01

    Full Text Available Online archives are of increasing importance in Archaeological Informatics, but like any new genre they prompt a number of questions. What is their relationship to publication? What should go in them? How should they be delivered and indexed? Can they be preserved? Whilst their delivery requires technology, we must also consider how that technology should best be employed in the service of our discipline. This article attempts to address some of these questions but it need not be read from start to finish. The links from this summary provide one fairly linear route through the text but each section is self-contained and can also be accessed directly from the Contents page. The problems posed by effective publication of archaeological fieldwork have exercised the profession for many decades. The issues raised go to the core of discussion of whether preservation by record is a valid concept, and indeed whether archaeological data exist. There are different schools of thought about the relationship between publication and archiving, but hopefully we can accept that data are recorded observations but still agree that they have a re-use value for re-examination and re-interpretation. Since the 1960s archaeology has experienced a publication crisis point. The scenario is familiar. Excavation is destruction; it is an unrepeatable experiment and the archaeologist has a professional obligation to make a full and accessible record of his/her observations. Yet full publication is increasingly expensive and difficult, and excavation monographs are read by few people, and bought by even fewer. In England the development of post-PPG16 fieldwork has exacerbated the problem by creating a mountain of unpublished grey literature and making the work of synthesis even harder; a similar situation exists in other countries. Meanwhile museum archives are also reaching breaking point; most are running out of storage space, few can provide facilities for access, and

  19. Update History of This Database - SSBD | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us SSBD Update History of This Database Date Update contents 2016/07/25 SSBD English archive si...tion Download License Update History of This Database Site Policy | Contact Us Update History of This Database - SSBD | LSDB Archive ... ...te is opened. 2013/09/03 SSBD ( http://ssbd.qbic.riken.jp/ ) is opened. About This Database Database Descrip

  20. The Comparison Study of Six University Archives

    Directory of Open Access Journals (Sweden)

    Chun-Fen Liu

    2004-03-01

    Full Text Available The university archives is not only the extension of a building, but also includes the archival records, archivists and equipments. The university archives is the historical memory of a university, which could let people to predict the future by reviewing the past. The university archives has abundant collections, both teachers and students can review history of this university. This paper mainly compares six university archives of Taiwan, and the interviewing method is used in this research. After comparison of the six university archives, we have found the six university archives have different organizational structures, budgets, and functions. Finally the authors propose some suggestions.[Article content in Chinese

  1. Archives Library Information Center

    Data.gov (United States)

    National Archives and Records Administration — ALIC is an online library catalog of books, periodicals, and other materials contained in Archives I and II and book collections located in other facilities.

  2. The Ethics of Archival Research

    Science.gov (United States)

    McKee, Heidi A.; Porter, James E.

    2012-01-01

    What are the key ethical issues involved in conducting archival research? Based on examination of cases and interviews with leading archival researchers in composition, this article discusses several ethical questions and offers a heuristic to guide ethical decision making. Key to this process is recognizing the person-ness of archival materials.…

  3. GRIP Database original data - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us GRI...PDB GRIP Database original data Data detail Data name GRIP Database original data DOI 10....18908/lsdba.nbdc01665-006 Description of data contents GRIP Database original data It consists of data table...s and sequences. Data file File name: gripdb_original_data.zip File URL: ftp://ftp.biosciencedbc.jp/archive/gripdb/LATEST/gri...e Database Description Download License Update History of This Database Site Policy | Contact Us GRIP Database original data - GRIPDB | LSDB Archive ...

  4. Dynamic Data Management Based on Archival Process Integration at the Centre for Environmental Data Archival

    Science.gov (United States)

    Conway, Esther; Waterfall, Alison; Pepler, Sam; Newey, Charles

    2015-04-01

    In this paper we decribe a business process modelling approach to the integration of exisiting archival activities. We provide a high level overview of existing practice and discuss how procedures can be extended and supported through the description of preservation state. The aim of which is to faciliate the dynamic controlled management of scientific data through its lifecycle. The main types of archival processes considered are: • Management processes that govern the operation of an archive. These management processes include archival governance (preservation state management, selection of archival candidates and strategic management) . • Operational processes that constitute the core activities of the archive which maintain the value of research assets. These operational processes are the acquisition, ingestion, deletion, generation of metadata and preservation actvities, • Supporting processes, which include planning, risk analysis and monitoring of the community/preservation environment. We then proceed by describing the feasability testing of extended risk management and planning procedures which integrate current practices. This was done through the CEDA Archival Format Audit which inspected British Atmospherics Data Centre and National Earth Observation Data Centre Archival holdings. These holdings are extensive, comprising of around 2PB of data and 137 million individual files which were analysed and characterised in terms of format based risk. We are then able to present an overview of the risk burden faced by a large scale archive attempting to maintain the usability of heterogeneous environmental data sets. We conclude by presenting a dynamic data management information model that is capable of describing the preservation state of archival holdings throughout the data lifecycle. We provide discussion of the following core model entities and their relationships: • Aspirational entities, which include Data Entity definitions and their associated

  5. Archives: Medical Journal of Zambia

    African Journals Online (AJOL)

    Items 1 - 39 of 39 ... Archives: Medical Journal of Zambia. Journal Home > Archives: Medical Journal of Zambia. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 39 of 39 Items ...

  6. Archives: Annals of Pediatric Surgery

    African Journals Online (AJOL)

    Items 1 - 32 of 32 ... Archives: Annals of Pediatric Surgery. Journal Home > Archives: Annals of Pediatric Surgery. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 32 of 32 Items ...

  7. Archives: Town and Regional Planning

    African Journals Online (AJOL)

    Items 1 - 12 of 12 ... Archives: Town and Regional Planning. Journal Home > Archives: Town and Regional Planning. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 12 of 12 ...

  8. Archives: Egyptian Journal of Biology

    African Journals Online (AJOL)

    Items 1 - 17 of 17 ... Archives: Egyptian Journal of Biology. Journal Home > Archives: Egyptian Journal of Biology. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 17 of 17 Items ...

  9. Archives: Pan African Medical Journal

    African Journals Online (AJOL)

    Items 1 - 28 of 28 ... Archives: Pan African Medical Journal. Journal Home > Archives: Pan African Medical Journal. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 28 of 28 Items ...

  10. Archives: Orient Journal of Medicine

    African Journals Online (AJOL)

    Items 1 - 26 of 26 ... Archives: Orient Journal of Medicine. Journal Home > Archives: Orient Journal of Medicine. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 26 of 26 Items ...

  11. Archives: Libyan Journal of Medicine

    African Journals Online (AJOL)

    Items 1 - 23 of 23 ... Archives: Libyan Journal of Medicine. Journal Home > Archives: Libyan Journal of Medicine. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 23 of 23 Items ...

  12. Archives: African Crop Science Journal

    African Journals Online (AJOL)

    Items 1 - 50 of 99 ... Archives: African Crop Science Journal. Journal Home > Archives: African Crop Science Journal. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 50 of 99 ...

  13. Archives: African Crop Science Journal

    African Journals Online (AJOL)

    Items 51 - 99 of 99 ... Archives: African Crop Science Journal. Journal Home > Archives: African Crop Science Journal. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 51 - 99 of 99 ...

  14. The Index to Marine and Lacustrine Geological Samples: Improving Sample Accessibility and Enabling Current and Future Research

    Science.gov (United States)

    Moore, C.

    2011-12-01

    The Index to Marine and Lacustrine Geological Samples is a community designed and maintained resource enabling researchers to locate and request sea floor and lakebed geologic samples archived by partner institutions. Conceived in the dawn of the digital age by representatives from U.S. academic and government marine core repositories and the NOAA National Geophysical Data Center (NGDC) at a 1977 meeting convened by the National Science Foundation (NSF), the Index is based on core concepts of community oversight, common vocabularies, consistent metadata and a shared interface. Form and content of underlying vocabularies and metadata continue to evolve according to the needs of the community, as do supporting technologies and access methodologies. The Curators Consortium, now international in scope, meets at partner institutions biennially to share ideas and discuss best practices. NGDC serves the group by providing database access and maintenance, a list server, digitizing support and long-term archival of sample metadata, data and imagery. Over three decades, participating curators have performed the herculean task of creating and contributing metadata for over 195,000 sea floor and lakebed cores, grabs, and dredges archived in their collections. Some partners use the Index for primary web access to their collections while others use it to increase exposure of more in-depth institutional systems. The Index is currently a geospatially-enabled relational database, publicly accessible via Web Feature and Web Map Services, and text- and ArcGIS map-based web interfaces. To provide as much knowledge as possible about each sample, the Index includes curatorial contact information and links to related data, information and images; 1) at participating institutions, 2) in the NGDC archive, and 3) at sites such as the Rolling Deck to Repository (R2R) and the System for Earth Sample Registration (SESAR). Over 34,000 International GeoSample Numbers (IGSNs) linking to SESAR are

  15. An Archival Search For Young Globular Clusters in Galaxies

    Science.gov (United States)

    Whitmore, Brad

    1995-07-01

    One of the most intriguing results from HST has been the discovery of ultraluminous star clusters in interacting and merging galaxies. These clusters have the luminosities, colors, and sizes that would be expected of young globular clusters produced by the interaction. We propose to use the data in the HST Archive to determine how prevalent this phenomena is, and to determine whether similar clusters are produced in other environments. Three samples will be extracted and studied in a systematic and consistent manner: 1} interacting and merging galaxies, 2} starburst galaxies, 3} a control sample of ``normal'' galaxies. A preliminary search of the archives shows that there are at least 20 galaxies in each of these samples, and the number will grow by about 50 observations become available. The data will be used to determine the luminosity function, color histogram , spatial distribution, and structural properties of the clusters using the same techniques employed in our study of NGC 7252 {``Atoms -for-Peace'' galaxy} and NGC 4038/4039 {``The Antennae''}. Our ultimate goals are: 1} to understand how globular clusters form, and 2} to use the clusters as evolutionary tracers to unravel the histories of interacting galaxies.

  16. Archives: African Journal of Urology

    African Journals Online (AJOL)

    Items 1 - 50 of 66 ... Archives: African Journal of Urology. Journal Home > Archives: African Journal of Urology. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 50 of 66 Items, 1 2 ...

  17. Archives: Jos Journal of Medicine

    African Journals Online (AJOL)

    Items 1 - 18 of 18 ... Archives: Jos Journal of Medicine. Journal Home > Archives: Jos Journal of Medicine. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 18 of 18 Items. 2017 ...

  18. Archives: Edo Journal of Counselling

    African Journals Online (AJOL)

    Items 1 - 6 of 6 ... Archives: Edo Journal of Counselling. Journal Home > Archives: Edo Journal of Counselling. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 6 of 6 Items. 2011 ...

  19. Archives: les cahiers du cread

    African Journals Online (AJOL)

    Items 1 - 24 of 24 ... Archives: les cahiers du cread. Journal Home > Archives: les cahiers du cread. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 24 of 24 Items. 2016 ...

  20. Archives: Annals of Modern Education

    African Journals Online (AJOL)

    Items 1 - 8 of 8 ... Archives: Annals of Modern Education. Journal Home > Archives: Annals of Modern Education. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 8 of 8 Items. 2016 ...

  1. NASA's Astrophysics Data Archives

    Science.gov (United States)

    Hasan, H.; Hanisch, R.; Bredekamp, J.

    2000-09-01

    The NASA Office of Space Science has established a series of archival centers where science data acquired through its space science missions is deposited. The availability of high quality data to the general public through these open archives enables the maximization of science return of the flight missions. The Astrophysics Data Centers Coordinating Council, an informal collaboration of archival centers, coordinates data from five archival centers distiguished primarily by the wavelength range of the data deposited there. Data are available in FITS format. An overview of NASA's data centers and services is presented in this paper. A standard front-end modifyer called `Astrowbrowse' is described. Other catalog browsers and tools include WISARD and AMASE supported by the National Space Scince Data Center, as well as ISAIA, a follow on to Astrobrowse.

  2. Sequencing of real-world samples using a microfabricated hybrid device having unconstrained straight separation channels.

    Science.gov (United States)

    Liu, Shaorong; Elkin, Christopher; Kapur, Hitesh

    2003-11-01

    We describe a microfabricated hybrid device that consists of a microfabricated chip containing multiple twin-T injectors attached to an array of capillaries that serve as the separation channels. A new fabrication process was employed to create two differently sized round channels in a chip. Twin-T injectors were formed by the smaller round channels that match the bore of the separation capillaries and separation capillaries were incorporated to the injectors through the larger round channels that match the outer diameter of the capillaries. This allows for a minimum dead volume and provides a robust chip/capillary interface. This hybrid design takes full advantage, such as sample stacking and purification and uniform signal intensity profile, of the unique chip injection scheme for DNA sequencing while employing long straight capillaries for the separations. In essence, the separation channel length is optimized for both speed and resolution since it is unconstrained by chip size. To demonstrate the reliability and practicality of this hybrid device, we sequenced over 1000 real-world samples from Human Chromosome 5 and Ciona intestinalis, prepared at Joint Genome Institute. We achieved average Phred20 read of 675 bases in about 70 min with a success rate of 91%. For the similar type of samples on MegaBACE 1000, the average Phred20 read is about 550-600 bases in 120 min separation time with a success rate of about 80-90%.

  3. Download - PGDBj - Ortholog DB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available e Description Download License Update History of This Database Site Policy | Contact Us Download - PGDBj - Ortholog DB | LSDB Archive ... ...List Contact us PGDBj - Ortholog DB Download First of all, please read the license of this database. Data na...switchLanguage; BLAST Search Image Search Home About Archive Update History Data

  4. SODA: Smart Objects, Dumb Archives

    Science.gov (United States)

    Nelson, Michael L.; Maly, Kurt; Zubair, Mohammad; Shen, Stewart N. T.

    2004-01-01

    We present the Smart Object, Dumb Archive (SODA) model for digital libraries (DLs). The SODA model transfers functionality traditionally associated with archives to the archived objects themselves. We are exploiting this shift of responsibility to facilitate other DL goals, such as interoperability, object intelligence and mobility, and heterogeneity. Objects in a SODA DL negotiate presentation of content and handle their own terms and conditions. In this paper we present implementations of our smart objects, buckets, and our dumb archive (DA). We discuss the status of buckets and DA and how they are used in a variety of DL projects.

  5. Controlled power delivery for super-resolution imaging of biological samples using digital micromirror device

    Science.gov (United States)

    Valiya Peedikakkal, Liyana; Cadby, Ashley

    2017-02-01

    Localization based super resolution images of a biological sample is generally achieved by using high power laser illumination with long exposure time which unfortunately increases photo-toxicity of a sample, making super resolution microscopy, in general, incompatible with live cell imaging. Furthermore, the limitation of photobleaching reduces the ability to acquire time lapse images of live biological cells using fluorescence microscopy. Digital Light Processing (DLP) technology can deliver light at grey scale levels by flickering digital micromirrors at around 290 Hz enabling highly controlled power delivery to samples. In this work, Digital Micromirror Device (DMD) is implemented in an inverse Schiefspiegler telescope setup to control the power and pattern of illumination for super resolution microscopy. We can achieve spatial and temporal patterning of illumination by controlling the DMD pixel by pixel. The DMD allows us to control the power and spatial extent of the laser illumination. We have used this to show that we can reduce the power delivered to the sample to allow for longer time imaging in one area while achieving sub-diffraction STORM imaging in another using higher power densities.

  6. Proton NMR-based metabolite analyses of archived serial paired serum and urine samples from myeloma patients at different stages of disease activity identifies acetylcarnitine as a novel marker of active disease.

    Directory of Open Access Journals (Sweden)

    Alessia Lodi

    Full Text Available BACKGROUND: Biomarker identification is becoming increasingly important for the development of personalized or stratified therapies. Metabolomics yields biomarkers indicative of phenotype that can be used to characterize transitions between health and disease, disease progression and therapeutic responses. The desire to reproducibly detect ever greater numbers of metabolites at ever diminishing levels has naturally nurtured advances in best practice for sample procurement, storage and analysis. Reciprocally, since many of the available extensive clinical archives were established prior to the metabolomics era and were not processed in such an 'ideal' fashion, considerable scepticism has arisen as to their value for metabolomic analysis. Here we have challenged that paradigm. METHODS: We performed proton nuclear magnetic resonance spectroscopy-based metabolomics on blood serum and urine samples from 32 patients representative of a total cohort of 1970 multiple myeloma patients entered into the United Kingdom Medical Research Council Myeloma IX trial. FINDINGS: Using serial paired blood and urine samples we detected metabolite profiles that associated with diagnosis, post-treatment remission and disease progression. These studies identified carnitine and acetylcarnitine as novel potential biomarkers of active disease both at diagnosis and relapse and as a mediator of disease associated pathologies. CONCLUSIONS: These findings show that samples conventionally processed and archived can provide useful metabolomic information that has important implications for understanding the biology of myeloma, discovering new therapies and identifying biomarkers potentially useful in deciding the choice and application of therapy.

  7. Archival Education in Scandinavian Countries

    Directory of Open Access Journals (Sweden)

    Muhammet Hanefi Kutluoğlu

    2008-03-01

    Full Text Available Every country has responsibilities to provide the necessary personnel needed for their archival inheritance by education. Education can be shaped through tradition, historical inheritance and scientifi c necessities by defi ning the right educational method. Scandinavian countries have determined different education models based on their tradition, historical inheritance and requirements. In this article we focused on the formation of archival tradition, application of archival education in Scandinavian countries and the infl uence of the developments taking place in Europe on these countries. The relation between the archival education in European and Scandinavian countries is evaluated through a comparative method, and similarities to other countries are also evaluated. Finally, the present situation of archival education and the measures needed in this fi eld are taken into consideration.

  8. Digital Preservation at the Swiss Federal Archives

    International Nuclear Information System (INIS)

    Ohnesorge, Krystyna

    2012-01-01

    The Swiss Federal Archives (SFA) archives Swiss government data when it is no longer in use. The SFA is responsible for advising, inspecting and issuing directives in records management and archiving services in offices, agencies and institutions subjected to the Federal Act on Archiving; as well as archiving and disseminating records and data of archival value. With regard to RWM, it thus in fact is an additional regulator. The conceptual basis for digital archiving at the SFA is based on the ISO OAIS Open Archival Information System Reference Model (ISO 14721:2003). The SFA use a process-orientated approach. The SFA and the Federal Office decide jointly which documents and data are to be archived. Archive-worthy documents and data are selected on the basis of a systematic appraisal. Wherever possible this should be carried out pro-actively - before the documents are actually created - based on an indexing or classification system. If there is clarity, people will know what data - and metadata - to keep for the submission. The submission is split into several stages, from appraisal to the conclusion of the submission. Information is never changed once it is archived, except that it carries out conservation measures. New information is a new submission. The sustainable information management is a core expertise of national archives. The SFA preserves digital records and data and is responsible for their secure and appropriate safe-keeping, description and dissemination. For the archiving of relational databases (e.g. Microsoft Access, Oracle and SQL Server), the SFA have developed a format known as SIARD (Software Independent Archiving of Relational Databases). SIARD is an open standard and is supported by the SIARD Suite application, which can be used to convert relational databases into SIARD format. The SIARD Suite is now in use worldwide (over 170 downloads). The SFA distribute the SIARD Suite free of charge in conformity with the license agreement. Currently

  9. Taxon (Viridiplantae) - PGDBj - Ortholog DB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available of This Database Site Policy | Contact Us Taxon (Viridiplantae) - PGDBj - Ortholog DB | LSDB Archive ... ...List Contact us PGDBj - Ortholog DB Taxon (Viridiplantae) Data detail Data name Taxon (Viridiplantae) DOI 10...switchLanguage; BLAST Search Image Search Home About Archive Update History Data

  10. Taxon (Cyanobacteria) - PGDBj - Ortholog DB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available of This Database Site Policy | Contact Us Taxon (Cyanobacteria) - PGDBj - Ortholog DB | LSDB Archive ... ...List Contact us PGDBj - Ortholog DB Taxon (Cyanobacteria) Data detail Data name Taxon (Cyanobacteria) DOI 10...switchLanguage; BLAST Search Image Search Home About Archive Update History Data

  11. Toward a Greater Discourse: Issues in Religious Archives

    Directory of Open Access Journals (Sweden)

    Robert Presutti

    2010-06-01

    Full Text Available The topic of religious archives, a catalyst of much discussion in archival literature, has traditionally been overlooked within the discourse of the American Theological Library Association (ATLA. This essay provides a survey analysis of three pertinent issues in religious archives with the intention of generating a wider discussion on religious archives within ATLA. These issues include the role of graduate archival education, the effects of religious faith on both the archival record and the individual archivist, and the idea of a theology of archives. An extended review of the contributions of James O’Toole to the discussion of religious archives is utilized.

  12. Ball assisted device for analytical surface sampling

    Science.gov (United States)

    ElNaggar, Mariam S; Van Berkel, Gary J; Covey, Thomas R

    2015-11-03

    A system for sampling a surface includes a sampling probe having a housing and a socket, and a rolling sampling sphere within the socket. The housing has a sampling fluid supply conduit and a sampling fluid exhaust conduit. The sampling fluid supply conduit supplies sampling fluid to the sampling sphere. The sampling fluid exhaust conduit has an inlet opening for receiving sampling fluid carried from the surface by the sampling sphere. A surface sampling probe and a method for sampling a surface are also disclosed.

  13. Microbiological evaluation of ten French archives and link to occupational symptoms.

    Science.gov (United States)

    Roussel, S; Reboux, G; Millon, L; Parchas, M-D; Boudih, S; Skana, F; Delaforge, M; Rakotonirainy, M S

    2012-12-01

    Fungi that damage documents in archives may harm workers' health, depending on which mold species are inhaled, the concentrations of fungal species inhaled, and individual factors. Our aim was to identify and quantify fungi in archives and to investigate possible links with the symptoms experienced by workers. Ten French archives were sampled using an air impactor and electrostatic dust collectors. Allergies and general symptoms felt by 144 workers were reported using a self-report questionnaire. Utilizing culture-based analysis methods along with qPCR, Penicillium chrysogenum, Cladosporium sphaerospermum, and Aspergillus versicolor were the three main fungi in air and dust in terms of quantity and frequency. Median fungal concentrations in storage areas, ranged from 30 to 465 CFU/m(3). People working in the most contaminated archives did not report more symptoms of allergy than others. However, workers in contact with moldy documents reported more headaches (odds ratio, 2.4; 95% confidence interval, 1.1-5.3), fatigue (OR, 2.9; 95% CI, 1.2-6.7), eye irritation (OR, 5.4; 95% CI, 1.9-14.9), throat irritation (OR, 2.4; 95% CI, 1.0-5.7), coughing (OR, 3.2; 95% CI, 1.2-8.4), and rhinorrhea (OR, 2.6; 95% CI, 1.0-6.4) than others. Other parameters such as dust levels and concentrations of metabolites and chemical substances should be considered as confounding factors in further investigations to isolate the role of molds. Most studies about fungi and archives deal with the conservation of manuscripts and documents, and few discuss workers' health problems. Our study shows that archives do not represent a highly contaminated environment. Symptoms felt by workers were more often linked to direct contact with moldy documents than to high concentrations of mold in the air of archive storage areas. This study provides data on concentration levels in archives that could be used to interpret microbiological investigations in this type of environment in the future. © 2012 John

  14. Phenome data - High-sugar stress - DGBY | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...s.zip File size: 90KB File name: Original file: High-sugar_stress.xls File URL: ftp://ftp.biosciencedbc.jp/archive/dgby/LATEST/Hi... Center for Protein Sequences) About This Database Database Description Download License Update History of Thi...s Database Site Policy | Contact Us Phenome data - High-sugar stress - DGBY | LSDB Archive ... ...List Contact us DGBY Phenome data - High-sugar stress Data detail Data name Phenome data - High-sugar stress

  15. Study of microtip-based extraction and purification of DNA from human samples for portable devices

    Science.gov (United States)

    Fotouhi, Gareth

    DNA sample preparation is essential for genetic analysis. However, rapid and easy-to-use methods are a major challenge to obtaining genetic information. Furthermore, DNA sample preparation technology must follow the growing need for point-of-care (POC) diagnostics. The current use of centrifuges, large robots, and laboratory-intensive protocols has to be minimized to meet the global challenge of limited access healthcare by bringing the lab to patients through POC devices. To address these challenges, a novel extraction method of genomic DNA from human samples is presented by using heat-cured polyethyleneimine-coated microtips generating a high electric field. The microtip extraction method is based on recent work using an electric field and capillary action integrated into an automated device. The main challenges to the method are: (1) to obtain a stable microtip surface for the controlled capture and release of DNA and (2) to improve the recovery of DNA from samples with a high concentration of inhibitors, such as human samples. The present study addresses these challenges by investigating the heat curing of polyethyleneimine (PEI) coated on the surface of the microtip. Heat-cured PEI-coated microtips are shown to control the capture and release of DNA. Protocols are developed for the extraction and purification of DNA from human samples. Heat-cured PEI-coated microtip methods of DNA sample preparation are used to extract genomic DNA from human samples. It is discovered through experiment that heat curing of a PEI layer on a gold-coated surface below 150°C could inhibit the signal of polymerase chain reaction (PCR). Below 150°C, the PEI layer is not completely cured and dissolved off the gold-coated surface. Dissolved PEI binds with DNA to inhibit PCR. Heat curing of a PEI layer above 150°C on a gold-coated surface prevents inhibition to PCR and gel electrophoresis. In comparison to gold-coated microtips, the 225°C-cured PEI-coated microtips improve the

  16. Internet FAQ Archives - Online Education - faqs.org

    Science.gov (United States)

    faqs.org Internet FAQ Archives - Online Education faqs.org faqs.org - Internet FAQ Archives Internet FAQ Archives Online Education Internet RFC Index Usenet FAQ Index Other FAQs Documents Tools IFC Rated FAQs Internet RFC/STD/FYI/BCP Archives The Internet RFC series of documents is also available from

  17. Efficiency of PR communication in establishing links between archives and students: case study of the State Archives in Zadar

    Directory of Open Access Journals (Sweden)

    Goran Pavelin

    2013-03-01

    Full Text Available The aim of the paper is to highlight the changing role of archives and to use the case study to indicate the lacking communication with students due to the absence of PR activities, as well as to point to the difficulties of access to digital archival materials needed for student research. Using PR strategies the archives can sensitise the public for its material through different public programmes, exhibitions and fostering goodmedia relations. The archives try to develop good relations with target groups, in this case with students as potential users, taking into consideration their research needs and materials they are interested in. Research findings on student needs for archival data are extremely rare, even in recent American research. Therefore, we conducted this research using a questionnaire for students of four departments of the University of Zadar (geography, history, art history, tourism and communication, who were users of the State Archives in Zadar. The research results show whether the subjects use archival material, for what purposes, and what other resources they used prior to archival material. It also provides information on the level of familiarity with online archival material and use of web pages with archival resources. We can conclude that the students in Zadar are not well acquainted with the digital resources and use them rarely for their research purposes. The situation can be improved by having the State Archives in Zadar take a more proactive role in identifying target groups of students, their user profiles, difficulties they face, and by allowing a more flexible access to archival material. In addition to goo d relations with the Department of Information Sciences, the Archives should foster links with other departments and include them in planning and implementation of their programmes.

  18. Update History of This Database - fRNAdb | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us fRNAdb Update History of This Database Date Update contents 2016/03/29 fRNAdb English archiv...on Download License Update History of This Database Site Policy | Contact Us Update History of This Database - fRNAdb | LSDB Archive ... ...e site is opened. 2006/12 fRNAdb ( http://www.ncrna.org/ ) is opened. About This Database Database Descripti

  19. Digital information management: a progress report on the National Digital Mammography Archive

    Science.gov (United States)

    Beckerman, Barbara G.; Schnall, Mitchell D.

    2002-05-01

    Digital mammography creates very large images, which require new approaches to storage, retrieval, management, and security. The National Digital Mammography Archive (NDMA) project, funded by the National Library of Medicine (NLM), is developing a limited testbed that demonstrates the feasibility of a national breast imaging archive, with access to prior exams; patient information; computer aids for image processing, teaching, and testing tools; and security components to ensure confidentiality of patient information. There will be significant benefits to patients and clinicians in terms of accessible data with which to make a diagnosis and to researchers performing studies on breast cancer. Mammography was chosen for the project, because standards were already available for digital images, report formats, and structures. New standards have been created for communications protocols between devices, front- end portal and archive. NDMA is a distributed computing concept that provides for sharing and access across corporate entities. Privacy, auditing, and patient consent are all integrated into the system. Five sites, Universities of Pennsylvania, Chicago, North Carolina and Toronto, and BWXT Y12, are connected through high-speed networks to demonstrate functionality. We will review progress, including technical challenges, innovative research and development activities, standards and protocols being implemented, and potential benefits to healthcare systems.

  20. All-integrated and highly sensitive paper based device with sample treatment platform for Cd2+ immunodetection in drinking/tap waters.

    Science.gov (United States)

    López Marzo, Adaris M; Pons, Josefina; Blake, Diane A; Merkoçi, Arben

    2013-04-02

    Nowadays, the development of systems, devices, or methods that integrate several process steps into one multifunctional step for clinical, environmental, or industrial purposes constitutes a challenge for many ongoing research projects. Here, we present a new integrated paper based cadmium (Cd(2+)) immunosensing system in lateral flow format, which integrates the sample treatment process with the analyte detection process. The principle of Cd(2+) detection is based on competitive reaction between the cadmium-ethylenediaminetetraacetic acid-bovine serum albumin-gold nanoparticles (Cd-EDTA-BSA-AuNP) conjugate deposited on the conjugation pad strip and the Cd-EDTA complex formed in the analysis sample for the same binding sites of the 2A81G5 monoclonal antibody (mAb), specific to Cd-EDTA but not Cd(2+) free, which is immobilized onto the test line. This platform operates without any sample pretreatment step for Cd(2+) detection thanks to an extra conjugation pad that ensures Cd(2+) complexation with EDTA and interference masking through ovalbumin (OVA). The detection and quantification limits found for the device were 0.1 and 0.4 ppb, respectively, these being the lowest limits reported up to now for metal sensors based on paper. The accuracy of the device was evaluated by addition of known quantities of Cd(2+) to different drinking water samples and subsequent Cd(2+) content analysis. Sample recoveries ranged from 95 to 105% and the coefficient of variation for the intermediate precision assay was less than 10%. In addition, the results obtained here were compared with those obtained with the well-established inductively coupled plasma emission spectroscopy (ICPES) and the analysis of certificate standard samples.

  1. Archival analyses of eyewitness identification test outcomes: what can they tell us about eyewitness memory?

    Science.gov (United States)

    Horry, Ruth; Halford, Paul; Brewer, Neil; Milne, Rebecca; Bull, Ray

    2014-02-01

    Several archival studies of eyewitness identification have been conducted, but the results have been inconsistent and contradictory. We identify some avoidable pitfalls that have been present in previous analyses and present new data that address these pitfalls. We explored associations among various estimator variables and lineup outcomes for 833 "real life" lineups, including 588 lineups in which corroborating evidence of the suspect's guilt existed. Suspect identifications were associated with exposure duration, viewing distance, and the age of the witness. Nonidentifications were associated with the number of perpetrators. We also consider some of the inherent, unavoidable limitations with archival studies and consider what such studies can really tell researchers. We conclude that differences in sampling prohibit sensible comparisons between the results of laboratory and archival studies, and that the informational value of archival studies is actually rather limited.

  2. Influence of solar activity and environment on 10Be in recent natural archives

    International Nuclear Information System (INIS)

    Berggren, Ann-Marie

    2009-01-01

    Understanding the link between the Sun and climate is vital in the current incidence of global climate change, and 10 Be in natural archives constitutes an excellent tracer for this purpose. As cosmic rays enter the atmosphere, cosmogenic isotopes like 10 Be and 14 C are formed. Variations in solar activity modulate the amount of incoming cosmic rays, and thereby cosmogenic isotope production. Atmospherically produced 10 Be enters natural archives such as sediments and glaciers by wet and dry deposition within about a year of production. 10 Be from natural archives therefore provides information on past solar activity, and because these archives also contain climate information, solar activity and climate can be linked. One remaining question is to what degree 10 Be in natural archives reflects production, and to what extent the local and regional environment overprints the production signal. To explore this, 10 Be was measured at annual resolution over the last 600 years in a Greenland ice core. Measurement potentials for these samples benefited from the development of a new laboratory method of co-precipitating 10 Be with niobium. To diversify geographic location and archive media type, a pioneer study of measuring 10 Be with annual resolution in varved lake sediments from Finland was conducted, with samples from the entire 20th century. Pathways of 10 Be into lake sediments are more complex than into glacial ice, inferring that contemporary atmospheric conditions may not be recorded. Here, it is shown for the first time that tracing the 11-year solar cycle through lake sediment 10 Be variations is possible. Results also show that on an annual basis, 10 Be deposition in ice and sediment archives is affected by local environmental conditions. On a slightly longer timescale, however, diverse 10 Be records exhibit similar trends and a negative correlation with solar activity. Cyclic variability of 10 Be deposition persisted throughout past grand solar minima, when

  3. Planetary Data Archiving Activities of ISRO

    Science.gov (United States)

    Gopala Krishna, Barla; D, Rao J.; Thakkar, Navita; Prashar, Ajay; Manthira Moorthi, S.

    ISRO has launched its first planetary mission to moon viz., Chandrayaan-1 on October 22, 2008. This mission carried eleven instruments; a wealth of science data has been collected during its mission life (November 2008 to August 2009), which is archived at Indian Space Science Data Centre (ISSDC). The data centre ISSDC is responsible for the Ingest, storage, processing, Archive, and dissemination of the payload and related ancillary data in addition to real-time spacecraft operations support. ISSDC is designed to provide high computation power, large storage and hosting a variety of applications necessary to support all the planetary and space science missions of ISRO. State-of-the-art architecture of ISSDC provides the facility to ingest the raw payload data of all the science payloads of the science satellites in automatic manner, processes raw data and generates payload specific processed outputs, generate higher level products and disseminates the data sets to principal investigators, guest observers, payload operations centres (POC) and to general public. The data archive makes use of the well-proven archive standards of the Planetary Data System (PDS). The long term Archive for five payloads of Chandrayaan-1 data viz., TMC, HySI, SARA, M3 and MiniSAR is released from ISSDC on19th April 2013 (http://www.issdc.gov.in) to the users. Additionally DEMs generated from possible passes of Chandrayaan-1 TMC stereo data and sample map sheets of Lunar Atlas are also archived and released from ISSDC along with the LTA. Mars Orbiter Mission (MOM) is the recent planetary mission launched on October 22, 2013; currently enroute to MARS, carrying five instruments (http://www.isro.org) viz., Mars Color Camera (MCC) to map various morphological features on Mars with varying resolution and scales using the unique elliptical orbit, Methane Sensor for Mars (MSM) to measure total column of methane in the Martian atmosphere, Thermal Infrared Imaging Spectrometer (TIS) to map surface

  4. Update History of This Database - RMG | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us RMG Update History of This Database Date Update contents 2016/08/22 The contact address is c...dna.affrc.go.jp/ ) is opened. About This Database Database Description Download License Update Hi...story of This Database Site Policy | Contact Us Update History of This Database - RMG | LSDB Archive ... ... URL of the portal site is changed. 2013/08/07 RMG archive site is opened. 2002/09/25 RMG ( http://rmg.rice.

  5. Update History of This Database - DGBY | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us DGBY Update History of This Database Date Update contents 2014/10/20 The URL of the portal s...aro.affrc.go.jp/yakudachi/yeast/index.html ) is opened. About This Database Database Description Download License Update Hi...story of This Database Site Policy | Contact Us Update History of This Database - DGBY | LSDB Archive ... ... Expression of attribution in License is updated. 2012/03/08 DGBY English archive site is opened. 2006/10/02

  6. The FARC fuel archive of VVER

    International Nuclear Information System (INIS)

    Zizin, M.N.; Parfenova, N.A.; Proselkov, V.N.; Shishkov, L.K.

    1998-01-01

    The principles of organisation are explained and the structure of the FARC fuel archive for VVER reactors is described. The objective of the archive is accumulation of fuel data, data storage and obtaining the fuel using characteristics. The working version of fuel archive on 01.07.98 is realised, in which the data tables for fuel assemblies for 169 VVER-440 cycles and 35 VVER-1000 cycles are stored. There are two different versions of fuel archive - for VVER-440 (FARC) and for VVER-1000 (FARC1000). A structure of some tables and the texts of programs for them differ. The algorithms and codes for checking integrity, reasonableness and reliability of fuel archive data are developed. (author)

  7. Pathway enrichment and co-expression cluster analysis - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM...lusters File URL: ftp://ftp.biosciencedbc.jp/archive/fantom5/datafiles/phase1.3/extra/Co-expression_clusters...ite Policy | Contact Us Pathway enrichment and co-expression cluster analysis - FANTOM5 | LSDB Archive ...

  8. Archival Information Management System.

    Science.gov (United States)

    1995-02-01

    management system named Archival Information Management System (AIMS), designed to meet the audit trail requirement for studies completed under the...are to be archived to the extent that future reproducibility and interrogation of results will exist. This report presents a prototype information

  9. Update History of This Database - TogoTV | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us TogoTV Update History of This Database Date Update contents 2017/05/12 TogoTV English archiv...ription Download License Update History of This Database Site Policy | Contact Us Update History of This Database - TogoTV | LSDB Archive ... ...e site is opened. 2007/07/20 TogoTV ( http://togotv.dbcls.jp/ ) is opened. About This Database Database Desc

  10. Update History of This Database - ConfC | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us ConfC Update History of This Database Date Update contents 2016/09/20 ConfC English archive ...tion Download License Update History of This Database Site Policy | Contact Us Update History of This Database - ConfC | LSDB Archive ... ...site is opened. 2005/05/01 ConfC (http://mbs.cbrc.jp/ConfC/) is opened. About This Database Database Descrip

  11. Update History of This Database - tRNADB-CE | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us tRNAD...11/08/25 License is updated. 2010/03/29 tRNADB-CE English archive site is opened. 2008/7/1 tRNADB-CE( http:/...Download License Update History of This Database Site Policy | Contact Us Update History of This Database - tRNADB-CE | LSDB Archive ...

  12. Costs of Archival Storage

    DEFF Research Database (Denmark)

    Nielsen, Anders Bo; Thirifays, Alex; Kejser, Ulla Bøgvad

    2012-01-01

    to determine the costs of establishing and maintaining a preservation solution destined for long-term preservation of digital materials and to develop a tool capable of doing this operation. In order to fulfill the purposes, the project employed a combination of own and external experience as well as the OAIS......This paper presents an analysis of the cost of archival storage. The study is part of a project conducted by The Danish National Archives, The Royal Library, and The State and University Library to develop a generic cost model for digital preservation (CMDP). The purposes of the study were...... Reference Model as a framework to fully understand and identify the cost critical activities of bit-preservation as described in Archival Storage. We found that the costs of Archival Storage are obviously closely linked to the data volume, but also to the required preservation quality, especially...

  13. Developed a needle trap device with PDMS sorbent for microextraction of toluene and methyl ethyl ketone from aquatic samples using dynamic headspace

    Directory of Open Access Journals (Sweden)

    Sara Karimi Zeverdegani

    2016-09-01

    Full Text Available Introduction: Due to the widespread use of toxic chemicals in most workplaces that can lead to toxic effects on human, various chemical extraction technique have been defined for analysis these toxic substances in air, water and biological samples. The purpose of this research is extraction of  toluene and methyl ethyl ketone from aquatic samples with needle trap device and  one commercial sorbent. Methods: In this research, needle trap device was used to extraction of  toluene and methyl ethyl ketone in aquatic samples, so needles(size 20 were packed with PDMS and extraction was done with dynamic headspace needle trap device. Gas chromatography with - flame ionization detector was used to analysis and optimized extraction of two substances were obtained. Results: Results show that the optimum temperature and time extraction was similar for toluene and methyl ethyl ketone (30 ° C, 30 min, but the reproducibility of results and calibration curve that obtained for toluene was better than methyl ethyl ketone. Conclusion: Needle trap technique is inexpensive, sensitive and portable also this method has good recovery to extract small amounts of  toluene and methyl ethyketon from aquatic samples with polydimethylsiloxane.

  14. Protein (Viridiplantae) - PGDBj - Ortholog DB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available ase Description Download License Update History of This Database Site Policy | Contact Us Protein (Viridiplantae) - PGDBj - Ortholog DB | LSDB Archive ... ...List Contact us PGDBj - Ortholog DB Protein (Viridiplantae) Data detail Data name Protein (Viridiplantae) DO...switchLanguage; BLAST Search Image Search Home About Archive Update History Data

  15. License - Plabrain DB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us Plabrain... Alike 2.1 Japan . If you use data from this database, please be sure attribute this database as follows: Plabrain...of this database (http://dbarchive.lifesciencedb.jp/english/en/plabrain-db/desc.html) in the article or pape...se Description Download License Update History of This Database Site Policy | Contact Us License - Plabrain DB | LSDB Archive ...

  16. Miniaturized bead-beating device to automate full DNA sample preparation processes for gram-positive bacteria.

    Science.gov (United States)

    Hwang, Kyu-Youn; Kwon, Sung Hong; Jung, Sun-Ok; Lim, Hee-Kyun; Jung, Won-Jong; Park, Chin-Sung; Kim, Joon-Ho; Suh, Kahp-Yang; Huh, Nam

    2011-11-07

    We have developed a miniaturized bead-beating device to automate nucleic acids extraction from Gram-positive bacteria for molecular diagnostics. The microfluidic device was fabricated by sandwiching a monolithic flexible polydimethylsiloxane (PDMS) membrane between two glass wafers (i.e., glass-PDMS-glass), which acted as an actuator for bead collision via its pneumatic vibration without additional lysis equipment. The Gram-positive bacteria, S. aureus and methicillin-resistant S. aureus, were captured on surface-modified glass beads from 1 mL of initial sample solution and in situ lyzed by bead-beating operation. Then, 10 μL or 20 μL of bacterial DNA solution was eluted and amplified successfully by real-time PCR. It was found that liquid volume fraction played a crucial role in determining the cell lysis efficiency in a confined chamber by facilitating membrane deflection and bead motion. The miniaturized bead-beating operation disrupted most of S. aureus within 3 min, which turned out to be as efficient as the conventional benchtop vortexing machine or the enzyme-based lysis technique. The effective cell concentration was significantly enhanced with the reduction of initial sample volume by 50 or 100 times. Combination of such analyte enrichment and in situ bead-beating lysis provided an excellent PCR detection sensitivity amounting to ca. 46 CFU even for the Gram-positive bacteria. The proposed bead-beating microdevice is potentially useful as a nucleic acid extraction method toward a PCR-based sample-to-answer system. This journal is © The Royal Society of Chemistry 2011

  17. Bipolar Electrode Sample Preparation Devices

    Science.gov (United States)

    Wang, Yi (Inventor); Song, Hongjun (Inventor); Pant, Kapil (Inventor)

    2017-01-01

    An analyte selection device can include: a body defining a fluid channel having a channel inlet and channel outlet; a bipolar electrode (BPE) between the inlet and outlet; one of an anode or cathode electrically coupled with the BPE on a channel inlet side of the BPE and the other of the anode or cathode electrically coupled with the BPE on a channel outlet side of the BPE; and an electronic system operably coupled with the anode and cathode so as to polarize the BPE. The fluid channel can have any shape or dimension. The channel inlet and channel outlet can be longitudinal or lateral with respect to the longitudinal axis of the channel. The BPE can be any metallic member, such as a flat plate on a wall or mesh as a barrier BPE. The anode and cathode can be located at a position that polarizes the BPE.

  18. Archiving Electronic Publications - a Librarian's Point of View

    Science.gov (United States)

    Grothkopf, U.

    Archiving electronic journals is complex. There are many questions: Who is responsible for archiving? What is archived? How many copies should be archived. How can one ensure the integrity of electronic documents? How can access be maintained? Technology will provide some answers. Electronic archives will require periodic refreshing and migration to new technology. Many factors remain unknown at present.

  19. A Background to Motion Picture Archives.

    Science.gov (United States)

    Fletcher, James E.; Bolen, Donald L., Jr.

    The emphasis of archives is on the maintenance and preservation of materials for scholarly research and professional reference. Archives may be established as separate entities or as part of a library or museum. Film archives may include camera originals (positive and negative), sound recordings, outtakes, scripts, contracts, advertising…

  20. Protein (Cyanobacteria) - PGDBj - Ortholog DB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available ut This Database Database Description Download License Update History of This Database Site Policy | Contact Us Protein (Cyanobacteria) - PGDBj - Ortholog DB | LSDB Archive ... ...List Contact us PGDBj - Ortholog DB Protein (Cyanobacteria) Data detail Data name Protein (Cyanobacteria) DO...switchLanguage; BLAST Search Image Search Home About Archive Update History Data

  1. Reframing transitions and contesting memories: The archive and the archival object in Peruvian cinema

    OpenAIRE

    Barrow, Sarah

    2015-01-01

    This essay considers the stories behind the production and screening of two very different Peruvian films that both reveal much about the way the archive, the archival object and archival fragment have worked to disrupt and force a reconsideration of key moments in Peruvian political history of the twentieth century. One, a feature film by Francisco Lombardi, Ojos que no ven/Eyes that don’t see (2003), provides a provocative perspective on the impact of the televisual revelations of the corru...

  2. Interoperable Access to NCAR Research Data Archive Collections

    Science.gov (United States)

    Schuster, D.; Ji, Z.; Worley, S. J.; Manross, K.

    2014-12-01

    The National Center for Atmospheric Research (NCAR) Research Data Archive (RDA) provides free access to 600+ observational and gridded dataset collections. The RDA is designed to support atmospheric and related sciences research, updated frequently where datasets have ongoing production, and serves data to 10,000 unique users annually. The traditional data access options include web-based direct archive file downloads, user selected data subsets and format conversions produced by server-side computations, and client and cURL-based APIs for routine scripted data retrieval. To enhance user experience and utility, the RDA now also offers THREDDS Data Server (TDS) access for many highly valued dataset collections. TDS offered datasets are presented as aggregations, enabling users to access an entire dataset collection, that can be comprised of 1000's of files, through a single virtual file. The OPeNDAP protocol, supported by the TDS, allows compatible tools to open and access these virtual files remotely, and make the native data file format transparent to the end user. The combined functionality (TDS/OPeNDAP) gives users the ability to browse, select, visualize, and download data from a complete dataset collection without having to transfer archive files to a local host. This presentation will review the TDS basics and describe the specific TDS implementation on the RDA's diverse archive of GRIB-1, GRIB-2, and gridded NetCDF formatted dataset collections. Potential future TDS implementation on in-situ observational dataset collections will be discussed. Illustrative sample cases will be used to highlight the end users benefits from this interoperable data access to the RDA.

  3. A Lab on a chip device for rapid identification of Avian Influenza virus by on-chip sample preparation and solid phase PCR

    DEFF Research Database (Denmark)

    Yi, Sun; Dhumpa, Raghuram; Bang, Dang Duong

    2009-01-01

    In this paper, we describe a novel lab-on-a-chip device for fast AIV screening by integrating DNA microarray-based solid phase PCR on microchip. The device can handle viral samples in an automatic way. Moreover, multiplex PCR and sequence detection are done in one-step, which greatly simplifies...

  4. Rapid surface sampling and archival record system

    Energy Technology Data Exchange (ETDEWEB)

    Barren, E.; Penney, C.M.; Sheldon, R.B. [GE Corporate Research and Development Center, Schenectady, NY (United States)] [and others

    1995-10-01

    A number of contamination sites exist in this country where the area and volume of material to be remediated is very large, approaching or exceeding 10{sup 6} m{sup 2} and 10{sup 6} m{sup 3}. Typically, only a small fraction of this material is actually contaminated. In such cases there is a strong economic motivation to test the material with a sufficient density of measurements to identify which portions are uncontaminated, so extensively they be left in place or be disposed of as uncontaminated waste. Unfortunately, since contamination often varies rapidly from position to position, this procedure can involve upwards of one million measurements per site. The situation is complicated further in many cases by the difficulties of sampling porous surfaces, such as concrete. This report describes a method for sampling concretes in which an immediate distinction can be made between contaminated and uncontaminated surfaces. Sample acquisition and analysis will be automated.

  5. Archives: South African Journal of Botany

    African Journals Online (AJOL)

    Archives: South African Journal of Botany. Journal Home > Archives: South African Journal of Botany. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. This journal has not ...

  6. License - tRNADB-CE | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us tRNAD...-Share Alike 2.1 Japan. If you use data from this database, please be sure attribute this database as follows: tRNAD...: About This Database Database Description Download License Update History of This Database Site Policy | Contact Us License - tRNADB-CE | LSDB Archive ...

  7. Download - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM... and CAGE TSS aggregation fantom5_new_experimental_details.zip (273 KB) basic (1.3 TB) Simple search and dow...nload 3 (reprocessed)HeliscopeCAGE sequencing, Delve mapping and CAGE TSS aggregation fantom5_rp_exp_details...access [here]. About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Download - FANTOM5 | LSDB Archive ...

  8. Web Archives for the Analog Archivist: Using Webpages Archived by the Internet Archive to Improve Processing and Description

    OpenAIRE

    Gelfand, Aleksandr

    2018-01-01

    Twenty years ago the Internet Archive was founded with the wide-ranging mission of providing universal access to all knowledge. In the two decades since, that organization has captured and made accessible over 150 billion websites. By incorporating the use of Internet Archive's Wayback Machine into their workflows, archivists working primarily with analog records may enhance their ability in such tasks as the construction of a processing plan, the creation of more accurate historical descript...

  9. Archives: Ethiopian Journal of Health Sciences

    African Journals Online (AJOL)

    Items 1 - 50 of 65 ... Archives: Ethiopian Journal of Health Sciences. Journal Home > Archives: Ethiopian Journal of Health Sciences. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives ...

  10. Trace metal depositional patterns from an open pit mining activity as revealed by archived avian gizzard contents

    Energy Technology Data Exchange (ETDEWEB)

    Bendell, L.I., E-mail: bendell@sfu.ca

    2011-02-15

    Archived samples of blue grouse (Dendragapus obscurus) gizzard contents, inclusive of grit, collected yearly between 1959 and 1970 were analyzed for cadmium, lead, zinc, and copper content. Approximately halfway through the 12-year sampling period, an open-pit copper mine began activities, then ceased operations 2 years later. Thus the archived samples provided a unique opportunity to determine if avian gizzard contents, inclusive of grit, could reveal patterns in the anthropogenic deposition of trace metals associated with mining activities. Gizzard concentrations of cadmium and copper strongly coincided with the onset of opening and the closing of the pit mining activity. Gizzard zinc and lead demonstrated significant among year variation; however, maximum concentrations did not correlate to mining activity. The archived gizzard contents did provide a useful tool for documenting trends in metal depositional patterns related to an anthropogenic activity. Further, blue grouse ingesting grit particles during the time of active mining activity would have been exposed to toxicologically significant levels of cadmium. Gizzard lead concentrations were also of toxicological significance but not related to mining activity. This type of 'pulse' toxic metal exposure as a consequence of open-pit mining activity would not necessarily have been revealed through a 'snap-shot' of soil, plant or avian tissue trace metal analysis post-mining activity. - Research Highlights: {yields} Archived gizzard samples reveals mining history. {yields} Grit ingestion exposes grouse to cadmium and lead. {yields} Grit selection includes particles enriched in cadmium. {yields} Cadmium enriched particles are of toxicological significance.

  11. Issues and prospects of digitizing liberation movements' archives ...

    African Journals Online (AJOL)

    User

    collective memory. Keywords: digitization,. NAHECS, liberation archives, digitally born, audio- visual. Introduction and background to liberation archives. Archives are generally records of .... long term preservation and access to selected archival materials ..... by International Library of African Music. (ILAM) in. Rhodes.

  12. Life Sciences Data Archive (LSDA)

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Life Sciences Data Archive (LSDA) is an active archive that provides information and data from 1961 (Mercury Project) through current flight and flight analog...

  13. Validation of a new HPV self-sampling device for cervical cancer screening: The Cervical and Self-Sample In Screening (CASSIS) study.

    Science.gov (United States)

    El-Zein, Mariam; Bouten, Sheila; Louvanto, Karolina; Gilbert, Lucy; Gotlieb, Walter; Hemmings, Robert; Behr, Marcel A; Franco, Eduardo L; Liang, Victoria; Martins, Claudia; Duarte, Silvy; Sarban, Natalia; Geddes, Patricia; Massa, Ana; Samios, Kathrin; Aboufadl, Siham; Verdon, Sophie; Pereria, Cynthia; Lacroix, Isabelle

    2018-04-17

    We compared the self-sampling performance of the newly designed HerSwab™ device with a physician-collected cervical sample and another self-sample using the cobas® PCR Female swab for the detection of cervical intraepithelial neoplasia (CIN) and cancer. Women referred for colposcopy at McGill University affiliated hospital clinics collected two consecutive self-samples, one with HerSwab™ and one with cobas® swab, after receiving instructions. The order of sampling was randomized. The colposcopist then collected a cervical sample and conducted a colposcopic examination. Samples were tested for human papillomavirus (HPV) DNA. Sensitivity and specificity to detect CIN2+ and respective 95% confidence intervals (CI) were calculated to compare sampling approaches. The HPV testing agreement between samples was measured using the Kappa statistic. Of 1217 women enrolled, 1076 had complete results for HPV and cytology; 148 (13.8%) had CIN1, 147 (13.7%) had CIN2/3, and 5 (0.5%) had cancer. There was very good agreement between methods for HPV detection (HerSwab™ versus physician: kappa=0.84; cobas® swabs versus physician: kappa=0.81; HerSwab™ versus cobas® swabs: kappa=0.87). The sensitivity of HPV detection for CIN2+ was 87.6% (95%CI: 79.8-93.2) with self-sampling using HerSwab™, 88.6% (95%CI: 80.9-94.0) with self-sampling using the cobas® swab, and 92.4% (95%CI: 85.5-96.7) with physician sampling. Corresponding estimates of specificity were 58.1% (95%CI: 54.1-62.1), 55.0% (95%CI: 50.9-59.0) and 58.7% (95%CI: 54.6-62.6). Cytology (ASC-US or more severe) done on the physician-collected specimen was 80.2% (95%CI: 70.8-87.6) sensitive and 61.4% (95%CI: 57.2-65.5) specific for CIN2+. The HerSwab™ had good agreement with physician sampling in detecting HPV, and adequate performance in detecting high-grade lesions among women referred to colposcopy for abnormal cytology. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Archives: South African Journal of Education

    African Journals Online (AJOL)

    Items 1 - 50 of 66 ... Archives: South African Journal of Education. Journal Home > Archives: South African Journal of Education. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 50 ...

  15. Archives: West African Journal of Medicine

    African Journals Online (AJOL)

    Items 1 - 40 of 40 ... Archives: West African Journal of Medicine. Journal Home > Archives: West African Journal of Medicine. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 40 of ...

  16. Archives: Journal of Psychology in Africa

    African Journals Online (AJOL)

    Archives: Journal of Psychology in Africa. Journal Home > Archives: Journal of Psychology in Africa. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 4 of 4 Items. 2005. Vol 15 ...

  17. Providing comprehensive and consistent access to astronomical observatory archive data: the NASA archive model

    Science.gov (United States)

    McGlynn, Thomas; Fabbiano, Giuseppina; Accomazzi, Alberto; Smale, Alan; White, Richard L.; Donaldson, Thomas; Aloisi, Alessandra; Dower, Theresa; Mazzerella, Joseph M.; Ebert, Rick; Pevunova, Olga; Imel, David; Berriman, Graham B.; Teplitz, Harry I.; Groom, Steve L.; Desai, Vandana R.; Landry, Walter

    2016-07-01

    Since the turn of the millennium a constant concern of astronomical archives have begun providing data to the public through standardized protocols unifying data from disparate physical sources and wavebands across the electromagnetic spectrum into an astronomical virtual observatory (VO). In October 2014, NASA began support for the NASA Astronomical Virtual Observatories (NAVO) program to coordinate the efforts of NASA astronomy archives in providing data to users through implementation of protocols agreed within the International Virtual Observatory Alliance (IVOA). A major goal of the NAVO collaboration has been to step back from a piecemeal implementation of IVOA standards and define what the appropriate presence for the US and NASA astronomy archives in the VO should be. This includes evaluating what optional capabilities in the standards need to be supported, the specific versions of standards that should be used, and returning feedback to the IVOA, to support modifications as needed. We discuss a standard archive model developed by the NAVO for data archive presence in the virtual observatory built upon a consistent framework of standards defined by the IVOA. Our standard model provides for discovery of resources through the VO registries, access to observation and object data, downloads of image and spectral data and general access to archival datasets. It defines specific protocol versions, minimum capabilities, and all dependencies. The model will evolve as the capabilities of the virtual observatory and needs of the community change.

  18. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  19. The new European Hubble archive

    Science.gov (United States)

    De Marchi, Guido; Arevalo, Maria; Merin, Bruno

    2016-01-01

    The European Hubble Archive (hereafter eHST), hosted at ESA's European Space Astronomy Centre, has been released for public use in October 2015. The eHST is now fully integrated with the other ESA science archives to ensure long-term preservation of the Hubble data, consisting of more than 1 million observations from 10 different scientific instruments. The public HST data, the Hubble Legacy Archive, and the high-level science data products are now all available to scientists through a single, carefully designed and user friendly web interface. In this talk, I will show how the the eHST can help boost archival research, including how to search on sources in the field of view thanks to precise footprints projected onto the sky, how to obtain enhanced previews of imaging data and interactive spectral plots, and how to directly link observations with already published papers. To maximise the scientific exploitation of Hubble's data, the eHST offers connectivity to virtual observatory tools, easily integrates with the recently released Hubble Source Catalog, and is fully accessible through ESA's archives multi-mission interface.

  20. The Rosetta Science Archive: Status and Plans for Completing and Enhancing the Archive Content

    Science.gov (United States)

    Heather, D.; Barthelemy, M.; Fraga, D.; Grotheer, E.; O'Rourke, L.; Taylor, M.

    2017-09-01

    On 30 September 2016, Rosetta's signal flat-lined, confirming that the spacecraft had completed its incredible mission by landing on the surface of Comet 67P/Churyumov-Gerasimenko. Although this marked an end to the spacecraft's active operations, intensive work is still on-going with instrument teams preparing their final science data increments for delivery and ingestion into ESA's Planetary Science Archive (PSA). In addition to this, ESA is establishing contracts with a number of instrument teams to enhance and improve their data and documentation in an effort to provide the best long- term archive possible for the Rosetta mission. This presentation will outline the current status of the Rosetta archive, as well as highlighting some of the 'enhanced archiving' activities planned and underway with the various instrument teams on Rosetta to ensure the scientific legacy of the mission.

  1. Prediction information - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us GRI...a.nbdc01665-004 Description of data contents Predicted GPCR interaction regions Data file File name: gripdb_...predicted_info.zip File URL: ftp://ftp.biosciencedbc.jp/archive/gripdb/LATEST/gripdb_predicted_info.zip File... size: 219 KB Simple search URL http://togodb.biosciencedbc.jp/togodb/view/gripdb...entries Data item Description ID Prediction information ID GRIP ID GRIP ID related wigh the prediction Predi

  2. Envirion - KEGG MEDICUS | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available [ Credits ] English ]; } else if ( url.search(//en//) != -1 ) { url = url.replace(/...switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us KEGG MEDI...y approved drugs. Data file File name: kegg_medicus_environ_en.zip File URL: ftp:...//ftp.biosciencedbc.jp/archive/kegg-medicus/LATEST/kegg_medicus_environ_en.zip File size: 79 KB Simple searc...h URL http://togodb.biosciencedbc.jp/togodb/view/kegg_medicus_environ_en Data acquisition method - Data anal

  3. Disease - KEGG MEDICUS | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available [ Credits ] English ]; } else if ( url.search(//en//) != -1 ) { url = url.replace(/...switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us KEGG MEDI...bling computational processing and analysis of disease data. Data file File name: kegg_medi...cus_disease_en.zip File URL: ftp://ftp.biosciencedbc.jp/archive/kegg-medicus/LATEST/kegg_medicus_d...isease_en.zip File size: 733 KB Simple search URL http://togodb.biosciencedbc.jp/togodb/view/kegg_medicus_di

  4. Drug - KEGG MEDICUS | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available [ Credits ] English ]; } else if ( url.search(//en//) != -1 ) { url = url.replace(/...switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us KEGG MEDI...metabolizing enzyme, and other molecular interaction network information. Data file File name: kegg_medi...cus_drug_en.zip File URL: ftp://ftp.biosciencedbc.jp/archive/kegg-medicus/LATEST/kegg_medi...cus_drug_en.zip File size: 5.2 MB Simple search URL http://togodb.biosciencedbc.jp/togodb/view/kegg_medi

  5. License - KEGG MEDICUS | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available [ Credits ] English ]; } else if ( url.search(//en//) != -1 ) { url = url.replace(/...switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us KEGG MEDI...ion-NonCommercial-NoDerivs 2.1 Japan. If you use data from this database, please be sure attribute this data...whole of this database, and acquire data; and freely redistribute part or whole of the data from this databa...This Database Site Policy | Contact Us License - KEGG MEDICUS | LSDB Archive ...

  6. Update History of This Database - KAIKOcDNA | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us KAIKOcDNA Update History of This Database Date Update contents 2014/10/20 The URL of the dat... database ( http://sgp.dna.affrc.go.jp/EST/ ) is opened. About This Database Database Description Download License Update Hi...story of This Database Site Policy | Contact Us Update History of This Database - KAIKOcDNA | LSDB Archive ... ...abase maintenance site is changed. 2014/10/08 KAIKOcDNA English archive site is opened. 2004/04/12 KAIKOcDNA

  7. Update History of This Database - TP Atlas | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us TP Atlas Update History of This Database Date Update contents 2013/12/16 The email address i...s ( http://www.tanpaku.org/tpatlas/ ) is opened. About This Database Database Description Download License Update History of Thi...s Database Site Policy | Contact Us Update History of This Database - TP Atlas | LSDB Archive ... ...n the contact information is corrected. 2013/11/19 TP Atlas English archive site is opened. 2008/4/1 TP Atla

  8. Update History of This Database - KEGG MEDICUS | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available glish archive site is opened. 2010/10/01 KEGG MEDICUS ( http://www.kegg.jp/kegg/medicus/ ) is opened. About ...[ Credits ] English ]; } else if ( url.search(//en//) != -1 ) { url = url.replace(/...switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us KEGG MEDI...CUS Update History of This Database Date Update contents 2014/05/09 KEGG MEDICUS En...This Database Database Description Download License Update History of This Database Site Policy | Contact Us Update History of This Database - KEGG MEDICUS | LSDB Archive ...

  9. Using Mobile Device Samples to Estimate Traffic Volumes

    Science.gov (United States)

    2017-12-01

    In this project, TTI worked with StreetLight Data to evaluate a beta version of its traffic volume estimates derived from global positioning system (GPS)-based mobile devices. TTI evaluated the accuracy of average annual daily traffic (AADT) volume :...

  10. Archives: Journal of Mining and Geology

    African Journals Online (AJOL)

    Items 1 - 13 of 13 ... Archives: Journal of Mining and Geology. Journal Home > Archives: Journal of Mining and Geology. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 13 of 13 ...

  11. Archives: African Journal of Oral Health

    African Journals Online (AJOL)

    Items 1 - 6 of 6 ... Archives: African Journal of Oral Health. Journal Home > Archives: African Journal of Oral Health. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 6 of 6 Items ...

  12. Study on archive management for nuclear facility decommissioning projects

    International Nuclear Information System (INIS)

    Huang Ling; Gong Jing; Luo Ning; Liao Bing; Zhou Hao

    2011-01-01

    This paper introduces the main features and status of the archive management for nuclear facility decommissioning projects, and explores and discusses the countermeasures in its archive management. Taking the practice of the archive management system of a reactor decommissioning project as an example, the paper illustrates the establishment of archive management system for the nuclear facility decommissioning projects. The results show that the development of a systematic archive management principle and system for nuclear decommissioning projects and the construction of project archives for the whole process from the design to the decommissioning by digitalized archive management system are one effective route to improve the complete, accurate and systematic archiving of project documents, to promote the standardization and effectiveness of the archive management and to ensure the traceability of the nuclear facility decommissioning projects. (authors)

  13. The FARC fuel archive of WWER

    International Nuclear Information System (INIS)

    Zizin, M.N.; Parfenova, N.A.; Proselkov, V.N.; Shishkov, L.K.

    1998-01-01

    The principles of organisation are explained and the structure of the FARC fuel archive for WWER reactors is circumscribed. The objective of archive is accumulation of fuel data, data storage and obtaining of fuel using characteristics. The working version of fuel archive on 01 July 1998 is realised, in which the data tables for fuel assemblies for 169 WWER-440 cycles and 35 WWER-1000 cycles are stored. There are two different versions of fuel archive - for WWER-440 (FARC) and for WWER-1000 (FARC1000). A structure of some tables and the texts of programs for them differ. (Authors)

  14. Data archiving and analysis for CWDD

    International Nuclear Information System (INIS)

    Coleman, T.A.; Novick, A.H.; Meystrik, C.C.; Marselle, J.R.

    1992-01-01

    A computer system has been developed to handle archiving and analysis of data acquired during operations of the Continuous Wave Deuterium Demonstrator (CWDD). Data files generated by the CWDD Instrumentation and Control system are transferred across a local area network to the CWDD Archive system where they are enlisted into the archive and stored on removeable media optical disk drives. A relational database management system maintains an on-line database catalog of all archived files. This database contains information about file contents and formats, and holds signal parameter configuration tables needed to extract and interpret data from the files. Software has been developed to assist the selection and retrieval of data on demand based upon references in the catalog. Data retrieved from the archive is transferred to commercial data visualization applications for viewing, plotting and analysis

  15. COMMUNITY AWARENESS FOR ARCHIVES IN TANZANIA: A ...

    African Journals Online (AJOL)

    Walter

    challenges facing Zanzibar National Archives (ZNA). The study ... legally preserved under the Records and Archives Management Act,. 2002. Lastly, in .... in the findings, the Archives face a lot of challenges on his operation such as lack of ...

  16. A dialogue between archive, knowledge and technology

    Directory of Open Access Journals (Sweden)

    Henrique Machado dos Santos

    2015-11-01

    Full Text Available Objective. Perform a brief reflection on knowledge management in archives, emphasizing the connections necessary for a dialogue between archive, knowledge and technology. Method. It consists in review of material previously published in the areas of Management Science, Archival Science and Information Science. The sources consulted consist of books, theses, texts on websites and scientific journal articles indexed in Google Scholar. Thus, the collected data is analyzed qualitatively. Results. There is a close relationship between the archive, knowledge and technology. In this sense, the document has the role of interlocutor in this dialogue. The interdisciplinary scenario envisioned, enhance existing rapprochement between the archival practices and knowledge management, in order to make possible a feedback cycle that will support the practices related to the management, either, of knowledge, of information or of documents. Conclusions. There is need for further studies to address the potential of the archives in order to fill possible gaps theory thus reach multiple looks more points interdisciplinary convergence. Finally, there is the informational potential of archives, then mediated by technology information, can enrich the knowledge management practices, and for this it is essential to strengthen the interdisciplinary relationships between Management Science, Archival Science and Information Science.

  17. Evaluation of Picture Archiving and Communication System (Pacs As A Process Improvement Sample (Sivas Numune Hospital Application

    Directory of Open Access Journals (Sweden)

    Ali Rıza İnce

    2013-09-01

    Full Text Available It is a realitythatthefirmsproducinggoods or services frequentlybenefited process improvementand similartechniques toachieve their objectives In today'scompetitive environment.Beingprocess-orientedmeans to give weight to the creation of quality but not to the control of quality. In this sense, process improvement is seen as an approach of Total Quality Management targeted. Hospital informationsystems are computer systems that collect andarchive all orthe majority of the hospitaldatafor use inthe assessment.It isa major problem that storage of visualdatawithout lossanddamage and also the being availableof these data as soon as possiblein this system.System that calledPACShas been developedto overcome this problem.PACS is an archiving system that archive the visual dataobtained fromimaging systems in different unitsin a spaceand, allows the transfer of these data to usersat different points when needed.In this study,efficiency of PACS asa process improvementtechniquewas examined by the application ofahospital.It is concluded that the system providea positive contributionto customers and hospitalas an example ofan importantprocess improvement at the evaluationof the results and implementation of the system.

  18. Report on emerging technologies for translational bioinformatics: a symposium on gene expression profiling for archival tissues

    Directory of Open Access Journals (Sweden)

    Waldron Levi

    2012-03-01

    Full Text Available Abstract Background With over 20 million formalin-fixed, paraffin-embedded (FFPE tissue samples archived each year in the United States alone, archival tissues remain a vast and under-utilized resource in the genomic study of cancer. Technologies have recently been introduced for whole-transcriptome amplification and microarray analysis of degraded mRNA fragments from FFPE samples, and studies of these platforms have only recently begun to enter the published literature. Results The Emerging Technologies for Translational Bioinformatics symposium on gene expression profiling for archival tissues featured presentations of two large-scale FFPE expression profiling studies (each involving over 1,000 samples, overviews of several smaller studies, and representatives from three leading companies in the field (Illumina, Affymetrix, and NuGEN. The meeting highlighted challenges in the analysis of expression data from archival tissues and strategies being developed to overcome them. In particular, speakers reported higher rates of clinical sample failure (from 10% to 70% than are typical for fresh-frozen tissues, as well as more frequent probe failure for individual samples. The symposium program is available at http://www.hsph.harvard.edu/ffpe. Conclusions Multiple solutions now exist for whole-genome expression profiling of FFPE tissues, including both microarray- and sequencing-based platforms. Several studies have reported their successful application, but substantial challenges and risks still exist. Symposium speakers presented novel methodology for analysis of FFPE expression data and suggestions for improving data recovery and quality assessment in pre-analytical stages. Research presentations emphasized the need for careful study design, including the use of pilot studies, replication, and randomization of samples among batches, as well as careful attention to data quality control. Regardless of any limitations in quantitave transcriptomics for

  19. Re-using the archive in video posters: a win-win for users and archives

    NARCIS (Netherlands)

    Sanders, W.; Salgado, Mariana

    2017-01-01

    Re-use of digital archival content means interpretation; and the ability to create new and original interpretations of cultural heritage materials constitutes necessary contemporary digital and media literacy skills for any (aspiring) scholar and, by extension, informed citizen. For archives, re-use

  20. Protein - Trypanosomes Database | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us Trypanoso...nhibitor of the protein. Data file File name: trypanosome.zip File URL: ftp://ftp....biosciencedbc.jp/archive/trypanosome/LATEST/trypanosome.zip File size: 1.4 KB Simple search URL http://togo...db.biosciencedbc.jp/togodb/view/trypanosome#en Data acquisition method - Data analysis method - Number of da...ndelian inheritance in Man ) map Location of the gene on a chromosome or its chromosome number pdb PDB ID (P

  1. Download - KEGG MEDICUS | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available [ Credits ] English ]; } else if ( url.search(//en//) != -1 ) { url = url.replace(/...switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us KEGG MEDI...search and download 1 README README_e.html - 2 Drug kegg_medicus_drug_en.zip (5.2... MB) Simple search and download 3 Environ kegg_medicus_environ_en.zip (79 KB) Simple search and download 4 Disease kegg_medi...nload License Update History of This Database Site Policy | Contact Us Download - KEGG MEDICUS | LSDB Archive ...

  2. Engaging With Colonial Archives: Reflections Of An End-User

    Directory of Open Access Journals (Sweden)

    Ayodeji Olukoju

    2016-06-01

    Full Text Available Official and/or public archives were a byproduct of colonial rule in Africa. (Archives are a byproduct of administrative governance everywhere. Given the density and diversity of colonial archival records, historians have tended to rely on them for the study of the colonial period. Publications on the use of archives have not captured the perspective of end-users, who often face peculiar challenges in the use of colonial and metropolitan archives. This paper provides an end-user perspective on colonial archives in Nigeria and the United Kingdom. It highlights the challenges of data collection and prospects of optimal use of archival source material. The discussion is of general application to users of colonial archives especially in the former British colonies in Africa.

  3. Update History of This Database - Q-TARO | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ...List Contact us Q-TARO Update History of This Database Date Update contents 2014/10/20 The URL of the portal...ption Download License Update History of This Database Site Policy | Contact Us Update History of This Database - Q-TARO | LSDB Archive ... ... site is changed. 2013/12/17 The URL of the portal site is changed. 2013/12/13 Q-TARO English archive site i...s opened. 2009/11/15 Q-TARO ( http://qtaro.abr.affrc.go.jp/ ) is opened. About This Database Database Descri

  4. ACRF Archive User Meeting Summary

    Energy Technology Data Exchange (ETDEWEB)

    SA Edgerton; RA McCord; DP Kaiser

    2007-10-30

    On October 30, 2007, the U.S. Department of Energy’s (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) sponsored an all-day workshop to assess the status of the ACRF Archive. Focus areas included usability of current functions, plans for revised functions, proposals for new functions, and an overarching discussion of new ideas. Although 13 scientists familiar with ACRF and the ARM Program were invited to the workshop, only 10 scientists were available to attend the workshop. ACRF consists of the infrastructure that was developed to support the ARM Program and includes the ACRF Archive (previously called the ARM Archive). The scientists who participated in the meeting ranged from those who used the Archive frequently to those who seldom or never had accessed the Archive. The group was spread across disciplines, i.e. modelers, conservationists, and others from universities and government laboratories. A few of the participants were funded by the ARM Program, but most were not funded currently by ARM. During the past year, several improvements were made to the ACRF Archive to link it with the ARM/ACRF web pages, add a shopping cart feature, and expand on search parameters. Additional modifications have been proposed and prototypes of these proposals were made available for the participants. The participants were given several exercises to do before the meeting, and their feedback was requested to help identify potential problems and shortcomings with the existing structure and to recommend improvements.

  5. Science in the archives pasts, presents, futures

    CERN Document Server

    2017-01-01

    "Science in the Archives" reveals affinities and continuities among the sciences of the archives, across many disciplines and centuries, in order to present a better picture of essential archival practices and, thereby, the meaning of science. For in both the natural and human sciences, archives of the most diverse forms make cumulative, collective knowledge possible. Yet in contrast to laboratories, observatories, or the field, archives have yet to be studied across the board as central sites of science. The volume covers episodes in the history of astronomy, geology, genetics, classical philology, climatology, history, medicine, and ancient natural philosophy, as well as fundamental practices such as collecting, retrieval strategies, and data mining. The time frame spans doxology in Greco-Roman antiquity to NSA surveillance techniques and the quantified-self movement. Each chapter explores the practices, politics, economics, and open-ended potential of the sciences of the archives, making this the first boo...

  6. Microbiological contamination with moulds in work environment in libraries and archive storage facilities.

    Science.gov (United States)

    Zielinska-Jankiewicz, Katarzyna; Kozajda, Anna; Piotrowska, Malgorzata; Szadkowska-Stanczyk, Irena

    2008-01-01

    Microbiological contamination with fungi, including moulds, can pose a significant health hazard to those working in archives or museums. The species involved include Aspergillus, Penicillium, Geotrichum, Alternaria, Cladosporium, Mucor, Rhizopus, Trichoderma, Fusarium which are associated mostly with allergic response of different types. The aim of the study was to analyse, both in quantitative and qualitative terms, workplace air samples collected in a library and archive storage facilities. Occupational exposure and the related health hazard from microbiological contamination with moulds were assessed in three archive storage buildings and one library. Air samples (total 60) were collected via impact method before work and at hourly intervals during work performance. Surface samples from the artifacts were collected by pressing a counting (RODAC) plate filled with malt extract agar against the surface of the artifacts. The air sample and surface sample analyses yielded 36 different mould species, classified into 19 genera, of which Cladosporium and Penicillium were the most prevalent. Twelve species were regarded as potentially pathogenic for humans: 8 had allergic and 11 toxic properties, the latter including Aspergillus fumigatus. Quantitative analysis revealed air microbiological contamination with moulds at the level ranging from 1.8 x 10(2)-2.3 x 10(3) cfu/m(3). In surface samples from library and archive artifacts, 11 fungal species were distinguished; the number of species per artifact varying from 1-6 and colony count ranging from 4 x 10(1) to 8-10(1) cfu/100 cm(2). Higher contamination levels were found only for Cladosporium cladosporioides (1.48 x 10(3) cfu/100 cm(2)) and Paecillomyces varioti (1.2 x 10(2) cfu/100 cm(2)). At the workposts examined, although no clearly visible signs of mould contamination could be found, the study revealed abundant micromycetes, with the predominant species of Cladosporium and Penicillium. The detected species included

  7. Care of architectural archival material

    Directory of Open Access Journals (Sweden)

    Perović-Ivović Svetlana

    2015-01-01

    Full Text Available The paper focuses on the complex issue of the preservation and maintenance of architectural records as a distinctive type of archival material, addressing the problems of care and storage of diverse oversize documents done on different supports: architectural drawings on drafting cloth, waxed cloth, paper, plastic film; reproductions such as blueprints, diazo prints, and other types of non-textual documents. Attention is paid to all types of damage caused both by internal factors, i.e. resulting from the nature of the support material, and by external factors involved in the degradation of architectural archival material. The paper also presents comparative conservation methods applied to architectural documents kept in the Archives of Yugoslavia. In conclusion, it points to the importance of preventive care as regards storage conditions, handling and display of this type of archival material.

  8. Web services interface of SSRF archive data analysis system

    International Nuclear Information System (INIS)

    Li Lin; Shen Liren; Zhu Qing; Wan Tianmin

    2007-01-01

    Accelerator database stores various static parameters and real-time data of accelerator. SSRF (Shanghai Synchrotron Radiation Facility) adopts relational database to save the data. We developed a data retrieval system based on XML Web Services for accessing the archive data. It includes a bottom layer interface and an interface applicable for accelerator physics. Client samples exemplifying how to consume the interface are given. The users can browse, retrieve and plot data by the client samples. Also, we give a method to test its stability. The test result and performance are described. (authors)

  9. Building an Archival Collections Portal

    Directory of Open Access Journals (Sweden)

    Stuart Marquis

    2008-06-01

    Full Text Available Columbia University Libraries has developed the Archival Collections Portal, a unified search system helping users discover archival resources in a streamlined way. We combined the power of Lucene and Solr to search XML, parse JSON objects, create EAD-compliant documents, and deliver results in an easy-to-use interface. By reusing MARC records and employing new search engine features and techniques, we are able to bring important and hard-to-find collections to researchers and archivists. The canonical home page of the Portal is http://www.columbia.edu/library/archival/.

  10. Experiment information - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us GRI...a.nbdc01665-002 Description of data contents Experimentally identified GPCR interaction regions Data file File name: gri...pdb_exp_info.zip File URL: ftp://ftp.biosciencedbc.jp/archive/gripdb/LATEST/gripdb_exp_info.zip ...File size: 6.2 KB Simple search URL http://togodb.biosciencedbc.jp/togodb/view/gri...es Data item Description ID Experiment information ID GRIP ID1 GRIP ID related wigh the experiment GRIP ID2 No. in GRI

  11. Designing a crisis management model in Iran’s archival centers: Pre-crisis stage

    Directory of Open Access Journals (Sweden)

    Maryam Nakhoda

    2018-03-01

    Full Text Available The purpose of this research is to design a crisis management model in the archival centers of Iran during the pre-crisis phase. The present study was conducted with a qualitative approach using the Grounded theory method. The necessary data was collected using semi-structured interviews. Data saturation was a major factor in determining the sample size. The research population included 20 crisis management specialists and managers of archives in Iran and the data analysis was performed in three stages: open, axial, and selective coding. The paradigmatic model derived from the findings of the research includes the sections of the causal conditions, strategies, intervening conditions and the underlying conditions and their outcomes. The causal conditions are located in two categories of internal crises such as biological crises and lack of proper management, and external crises such as natural disasters, fires and human-made crises. Intervener conditions and backgrounds include cat-egories such as lack of specialist staff training, lack of appropriate environmental conditions and management mechanisms, archival building and human resources issues. To prevent and mitigate the effects of the crisis in archives, some strategies are required such as modern education for resil-ience, teaching how to use documents, standardizing buildings and equipment (non-use of steel skeletons in building archives, use of concrete skeletons Armed or metal, as well as the use of walls and doors and floors of anti-fire covers in the building of archives and the establishment of multi-layer protective systems for the protection of documents.

  12. Failed fuel detection device

    International Nuclear Information System (INIS)

    Doi, Akira.

    1994-01-01

    The device of the present invention concerns a failed fuel detection device for a nuclear reactor, such as an FBR type reactor, using electroconductive coolants. A sampling port is disposed at the upper portion of the fuel assembly so as to cover the assembly, so that coolants in the fuel assembly are sampled to improve a device for detecting fuel failure. That is, when coolants in the fuel assembly are sampled from the sampling port, the flow of electroconductive coolants in an sampling tube is detected by a flowmeter, to control an electromagnetic pump. The flow of electroconductive coolants is stopped against the waterhead pressure and dynamic pressure of the conductive coolants, and a predetermined amount of the coolants is pumped up to the sampling tank. Gas is supplied to the pumped up coolants so that fissile products are transferred from the coolants to a gas phase. Radiation in the gas in a gas recycling system is measured to detect presence of fuel failure. (I.S.)

  13. Devices, Distractions and Digital Literacy: "Bring Your Own Device" to Polytech

    Science.gov (United States)

    Drew, Leoni; Forbes, Dianne

    2017-01-01

    The purpose of this study is to investigate the ways polytechnic students use personal mobile devices to support their learning. This study used purposive sampling and mixed methods to generate data about student ownership and use of mobile digital devices within a single institution. Findings reveal patterns of device ownership, insights into how…

  14. Digital audiovisual archives

    CERN Document Server

    Stockinger, Peter

    2013-01-01

    Today, huge quantities of digital audiovisual resources are already available - everywhere and at any time - through Web portals, online archives and libraries, and video blogs. One central question with respect to this huge amount of audiovisual data is how they can be used in specific (social, pedagogical, etc.) contexts and what are their potential interest for target groups (communities, professionals, students, researchers, etc.).This book examines the question of the (creative) exploitation of digital audiovisual archives from a theoretical, methodological, technical and practical

  15. Introducing the PRIDE Archive RESTful web services.

    Science.gov (United States)

    Reisinger, Florian; del-Toro, Noemi; Ternent, Tobias; Hermjakob, Henning; Vizcaíno, Juan Antonio

    2015-07-01

    The PRIDE (PRoteomics IDEntifications) database is one of the world-leading public repositories of mass spectrometry (MS)-based proteomics data and it is a founding member of the ProteomeXchange Consortium of proteomics resources. In the original PRIDE database system, users could access data programmatically by accessing the web services provided by the PRIDE BioMart interface. New REST (REpresentational State Transfer) web services have been developed to serve the most popular functionality provided by BioMart (now discontinued due to data scalability issues) and address the data access requirements of the newly developed PRIDE Archive. Using the API (Application Programming Interface) it is now possible to programmatically query for and retrieve peptide and protein identifications, project and assay metadata and the originally submitted files. Searching and filtering is also possible by metadata information, such as sample details (e.g. species and tissues), instrumentation (mass spectrometer), keywords and other provided annotations. The PRIDE Archive web services were first made available in April 2014. The API has already been adopted by a few applications and standalone tools such as PeptideShaker, PRIDE Inspector, the Unipept web application and the Python-based BioServices package. This application is free and open to all users with no login requirement and can be accessed at http://www.ebi.ac.uk/pride/ws/archive/. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  16. The Manifesto or the ten commandments of creating a private archive

    Directory of Open Access Journals (Sweden)

    Waldemar Chorążyczewski

    2013-03-01

    Full Text Available If, pursuant to the spirit of our time, and the interest of all the users of the archives, the versatility of the domain of archive studies, has the greatest value, then our goal is not to accumulate the archives of private provenance by the public or social data archives, but rather, to strive for the private archives in Poland to come about again. The public archives have natural right to exclusivity as far as amassing public archival materials is concerned. However, apart from that, parity of the right to cumulate materials ought to be upheld. Private archives ought to have the right to gather materials of other private archivists, as well as social data archives. The owners of such private archives, should also have the right to appoint an inheriting subject from among the public or private archives. Parity of archives will contribute towards an upswing in the position of the public archives as an institution of public trust. The public archives will keep a registry of private and social data archives. The latter will not be conveyed to anyone without the knowledge of the public archives. Public archives will also be required to take possession of the private and social data archive materials, in the event of their being closed down.

  17. Results of de-novo and Motif activity analyses - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM... JASPAR) Data file File name: Motifs File URL: ftp://ftp.biosciencedbc.jp/archive/fantom5/datafiles/phase1.3...tabase Database Description Download License Update History of This Database Site Policy | Contact Us Results of de-novo and Motif activity analyses - FANTOM5 | LSDB Archive ...

  18. Assessment of the potential respiratory hazard of volcanic ash from future Icelandic eruptions: a study of archived basaltic to rhyolitic ash samples.

    Science.gov (United States)

    Damby, David E; Horwell, Claire J; Larsen, Gudrun; Thordarson, Thorvaldur; Tomatis, Maura; Fubini, Bice; Donaldson, Ken

    2017-09-11

    The eruptions of Eyjafjallajökull (2010) and Grímsvötn (2011), Iceland, triggered immediate, international consideration of the respiratory health hazard of inhaling volcanic ash, and prompted the need to estimate the potential hazard posed by future eruptions of Iceland's volcanoes to Icelandic and Northern European populations. A physicochemical characterization and toxicological assessment was conducted on a suite of archived ash samples spanning the spectrum of past eruptions (basaltic to rhyolitic magmatic composition) of Icelandic volcanoes following a protocol specifically designed by the International Volcanic Health Hazard Network. Icelandic ash can be of a respirable size (up to 11.3 vol.% fiber-like particles were observed, but those present comprised glass or sodium oxides, and are not related to pathogenic natural fibers, like asbestos or fibrous zeolites, thereby limiting concern of associated respiratory diseases. None of the samples contained cristobalite or tridymite, and only one sample contained quartz, minerals of interest due to the potential to cause silicosis. Sample surface areas are low, ranging from 0.4 to 1.6 m 2  g -1 , which aligns with analyses on ash from other eruptions worldwide. All samples generated a low level of hydroxyl radicals (HO • ), a measure of surface reactivity, through the iron-catalyzed Fenton reaction compared to concurrently analyzed comparative samples. However, radical generation increased after 'refreshing' sample surfaces, indicating that newly erupted samples may display higher reactivity. A composition-dependent range of available surface iron was measured after a 7-day incubation, from 22.5 to 315.7 μmol m -2 , with mafic samples releasing more iron than silicic samples. All samples were non-reactive in a test of red blood cell-membrane damage. The primary particle-specific concern is the potential for future eruptions of Iceland's volcanoes to generate fine, respirable material and, thus, to

  19. 36 CFR 1253.1 - National Archives Building.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false National Archives Building... PUBLIC AVAILABILITY AND USE LOCATION OF RECORDS AND HOURS OF USE § 1253.1 National Archives Building. (a) The National Archives Building is located at 700 Pennsylvania Avenue, NW., Washington, DC 20408...

  20. Advanced digital image archival system using MPEG technologies

    Science.gov (United States)

    Chang, Wo

    2009-08-01

    Digital information and records are vital to the human race regardless of the nationalities and eras in which they were produced. Digital image contents are produced at a rapid pace from cultural heritages via digitalization, scientific and experimental data via high speed imaging sensors, national defense satellite images from governments, medical and healthcare imaging records from hospitals, personal collection of photos from digital cameras. With these mass amounts of precious and irreplaceable data and knowledge, what standards technologies can be applied to preserve and yet provide an interoperable framework for accessing the data across varieties of systems and devices? This paper presents an advanced digital image archival system by applying the international standard of MPEG technologies to preserve digital image content.

  1. Building a successful archival programme a practical approach

    CERN Document Server

    Ramos, Marisol

    2006-01-01

    This valuable resource provides information on best practices and solutions to successfully establish an archival programme; it uses a practical approach, without the use of technical or theoretical jargon. Additionally it serves as a companion text in a theoretical archival course. The book provides easy-to-follow advice on how to assess the information needs of any institution and the greater community for which the archives were created to serve. Guidelines for achievable goals are provided for starting an archives programme in an environment where a small budget or even a 'no budget' can threaten the future of the archives. First book that attempts to de-mystify archives Practical approaches without the use of technical jargon Easy to follow Plans of Action.

  2. Email-Set Visualization: Facilitating Re-Finding in Email Archives

    OpenAIRE

    Gorton, Douglas; Murthy, Uma; Vemuri, Naga Srinivas; Pérez-Quiñones, Manuel A.

    2007-01-01

    In this paper we describe ESVT – EmailSet Visualization Tool, an email archive tool that provides users a visualization to re-find and discover information in their email archive. ESVT is an end-to-end email archive tool that can be used from archiving a user’s email messages to visualizing queries on the email archive. We address email archiving by allowing import of email messages from an email server or from a standard existing email client. The central idea in ESVT’s visualization, an “em...

  3. Locating Archives within the Landscape: Records, Memory and Place

    Directory of Open Access Journals (Sweden)

    Jeannette Bastian

    2014-12-01

    Full Text Available Linking archives, memory and landscape, this article considers a series of questions, and attempts to address some of them: How do archivists and scholars who concern themselves with archives think about place and its relationship to records? Why and how is place archival? How are those archival relationships expressed and what do they signify for the people inhabiting that space? What are the memory implications of the relationship between place, archives and community and how are traditional archives both the products of place as well as influencers themselves upon the landscape?

  4. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    Science.gov (United States)

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  5. Power spectrum analysis for defect screening in integrated circuit devices

    Science.gov (United States)

    Tangyunyong, Paiboon; Cole Jr., Edward I.; Stein, David J.

    2011-12-01

    A device sample is screened for defects using its power spectrum in response to a dynamic stimulus. The device sample receives a time-varying electrical signal. The power spectrum of the device sample is measured at one of the pins of the device sample. A defect in the device sample can be identified based on results of comparing the power spectrum with one or more power spectra of the device that have a known defect status.

  6. Picture archiving and communication in radiology.

    Science.gov (United States)

    Napoli, Marzia; Nanni, Marinella; Cimarra, Stefania; Crisafulli, Letizia; Campioni, Paolo; Marano, Pasquale

    2003-01-01

    After over 80 years of exclusive archiving of radiologic films, at present, in Radiology, digital archiving is increasingly gaining ground. Digital archiving allows a considerable reduction in costs and space saving, but most importantly, immediate or remote consultation of all examinations and reports in the hospital clinical wards, is feasible. The RIS system, in this case, is the starting point of the process of electronic archiving which however is the task of PACS. The latter can be used as radiologic archive in accordance with the law provided that it is in conformance with some specifications as the use of optical long-term storage media or with electronic track of change. PACS archives, in a hierarchical system, all digital images produced by each diagnostic imaging modality. Images and patient data can be retrieved and used for consultation or remote consultation by the reporting radiologist who requires images and reports of previous radiologic examinations or by the referring physician of the ward. Modern PACS owing to the WEB server allow remote access to extremely simplified images and data however ensuring the due regulations and access protections. Since the PACS enables a simpler data communication within the hospital, security and patient privacy should be protected. A secure and reliable PACS should be able to minimize the risk of accidental data destruction, and should prevent non authorized access to the archive with adequate security measures in relation to the acquired knowledge and based on the technological advances. Archiving of data produced by modern digital imaging is a problem now present also in small Radiology services. The technology is able to readily solve problems which were extremely complex up to some years ago as the connection between equipment and archiving system owing also to the universalization of the DICOM 3.0 standard. The evolution of communication networks and the use of standard protocols as TCP/IP can minimize

  7. Scanning negatives and slides digitizing your photographic archive

    CERN Document Server

    Steinhoff, Sascha

    2009-01-01

    Many photographers have either moved into digital photography exclusively or use both analog and digital media in their work. In either case, there is sure to be an archive of slides and negatives that cannot be directly integrated into the new digital workflow, nor can it be archived in a digital format. Increasingly, photographers are trying to bridge this gap with the use of high-performance film scanners. In this 2nd edition, you will learn how to achieve the best possible digital image from a negative or a slide, and how to build a workflow to make this process efficient, repeatable, and reliable. The author uses Nikon's film scanners, but all steps can easily be accomplished while using a different scanner. The most common software tools for scanning (SilverFast, VueScan, NikonScan) are not only covered extensively in the book, but trial versions are also provided on a DVD, which also contains other useful tools for image editing, as well as numerous sample scans.

  8. A device for the application of uniaxial strain to single crystal samples for use in synchrotron radiation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gannon, L. [Clarendon Laboratory, University of Oxford Physics Department, Parks Road, Oxford OX1 3PU (United Kingdom); Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 ODE (United Kingdom); Bosak, A. [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Burkovsky, R. G. [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Peter the Great Saint-Petersburg Polytechnic University, 29 Politekhnicheskaya, 195251, St.-Petersburg (Russian Federation); Nisbet, G.; Hoesch, M., E-mail: Moritz.Hoesch@diamond.ac.uk [Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 ODE (United Kingdom); Petrović, A. P. [DPMC-MaNEP, Université de Genève, Quai Ernest-Ansermet 24, 1211 Genève 4 (Switzerland)

    2015-10-15

    We present the design, construction, and testing of a straining device compatible with many different synchrotron radiation techniques, in a wide range of experimental environments (including low temperature, high field and ultra-high vacuum). The device has been tested by X-ray diffraction on single crystal samples of quasi-one-dimensional Cs{sub 2}Mo{sub 6}Se{sub 6} and K{sub 2}Mo{sub 6}Se{sub 6}, in which microscopic strains up to a Δc/c = 0.12% ± 0.01% change in the c lattice parameters have been achieved. We have also used the device in an inelastic X-ray scattering experiment, to probe the strain-dependent speed of sound ν along the c axis. A reduction Δν/ν of up to −3.8% was obtained at a strain of Δc/c = 0.25% in K{sub 2}Mo{sub 6}Se{sub 6}.

  9. American archives and climate change: Risks and adaptation

    Directory of Open Access Journals (Sweden)

    T. Mazurczyk

    Full Text Available Climate change directly affects the future security of cultural resources. Cultural heritage and in particular, archives, are increasingly at risk of degradation due to climate change threats and triggers. This study evaluated present and future consequences of water-related climate change impacts using a mapping methodology to assess exposure of American archives to incompatible weather extremes. Susceptibility to climate change threats like sea level rise, storm surge, surface water flooding, and humidity, all influenced by a combination of temperature rise and increased precipitation, at a worst-case scenario were assessed for 1232 archival repositories. Results indicate that approximately 98.8% of archives are likely to be affected by at least one climate risk factor, though on average, most archives are at low risk of exposure (90% when risk factors are combined. Future storm surge plus sea level rise was likely to impact 17.7% of archival repositories with 22.1% affected by only storm surge and 4.3% affected by only sea level rise (1.8-m scenario. Fewer archives were likely to be susceptible to surface water flooding (2.4%. More than 90% of archives were estimated to have a temperature change greater than ±1 °C, with 7.5% of sites likely to change by ±10 °C, and 69.5% of archives were likely to receive at least 152 mm more rainfall by 2100 over current annual averages. In terms of sustainability, developing appropriate socio-economic planning schemes that integrate cumulative exposure of archives to future climate patterns is critically important for safeguarding society and its heritage. The outcomes from the risk assessment in this study aid in the decision-making process by promoting strategic adaptation protocols and providing administrators a way to prioritize archival management goals based on the expected severity of future climate change impacts. Keywords: Archives, Climate change, Sea level rise, Storm surge, Cultural

  10. Nuclear-like Seq in mt Genome - RMG | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available ar-like Seq in mt Genome Data detail Data name Nuclear-like Seq in mt Genome DOI 10...e Site Policy | Contact Us Nuclear-like Seq in mt Genome - RMG | LSDB Archive ... ...switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us RMG Nucle

  11. Cluster (Viridiplantae) - PGDBj - Ortholog DB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available 0”. This cluster ID is uniquely-assigned by the PGDBj Ortholog Database. Cluster size Number of proteins aff...r About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Cluster (Viridiplantae) - PGDBj - Ortholog DB | LSDB Archive ... ...List Contact us PGDBj - Ortholog DB Cluster (Viridiplantae) Data detail Data name Cluster (Viridiplantae) DO...switchLanguage; BLAST Search Image Search Home About Archive Update History Data

  12. Cluster (Cyanobacteria) - PGDBj - Ortholog DB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available 3090”. This cluster ID is uniquely-assigned by the PGDBj Ortholog Database. Cluster size Number of proteins ...ster About This Database Database Description Download License Update History of This Database Site Policy | Contact Us Cluster (Cyanobacteria) - PGDBj - Ortholog DB | LSDB Archive ... ...List Contact us PGDBj - Ortholog DB Cluster (Cyanobacteria) Data detail Data name Cluster (Cyanobacteria) DO...switchLanguage; BLAST Search Image Search Home About Archive Update History Data

  13. Database Dump - fRNAdb | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available List Contact us fRNAdb Database Dump Data detail Data name Database Dump DOI 10.18908/lsdba.nbdc00452-002 De... data (tab separeted text) Data file File name: Database_Dump File URL: ftp://ftp....biosciencedbc.jp/archive/frnadb/LATEST/Database_Dump File size: 673 MB Simple search URL - Data acquisition...s. Data analysis method - Number of data entries 4 files - About This Database Database Description Download... License Update History of This Database Site Policy | Contact Us Database Dump - fRNAdb | LSDB Archive ...

  14. Archives: Tropical Journal of Pharmaceutical Research

    African Journals Online (AJOL)

    Items 1 - 50 of 97 ... Archives: Tropical Journal of Pharmaceutical Research. Journal Home > Archives: Tropical Journal of Pharmaceutical Research. Log in or Register to get access to full text downloads.

  15. Archives: Nigerian Journal of Physiological Sciences

    African Journals Online (AJOL)

    Items 1 - 19 of 19 ... Archives: Nigerian Journal of Physiological Sciences. Journal Home > Archives: Nigerian Journal of Physiological Sciences. Log in or Register to get access to full text downloads.

  16. Archives: Nigerian Journal of Pharmaceutical Research

    African Journals Online (AJOL)

    Items 1 - 9 of 9 ... Archives: Nigerian Journal of Pharmaceutical Research. Journal Home > Archives: Nigerian Journal of Pharmaceutical Research. Log in or Register to get access to full text downloads.

  17. Archival Bone Marrow Samples: Suitable for Multiple Biomarker Analysis?

    DEFF Research Database (Denmark)

    Lund, Bendik; Najmi, A. Laeya; Wesolowska, Agata

    2015-01-01

    biopsies from 18 Danish and Norwegian childhood acute lymphoblastic leukemia patients were included and compared with corresponding blood samples. Samples were grouped according to the age of sample and whether WGA was performed or not. We found that measurements of DNA concentration after DNA extraction...

  18. Archiving Spectral Libraries in the Planetary Data System

    Science.gov (United States)

    Slavney, S.; Guinness, E. A.; Scholes, D.; Zastrow, A.

    2017-12-01

    Spectral libraries are becoming popular candidates for archiving in PDS. With the increase in the number of individual investigators funded by programs such as NASA's PDART, the PDS Geosciences Node is receiving many requests for support from proposers wishing to archive various forms of laboratory spectra. To accommodate the need for a standardized approach to archiving spectra, the Geosciences Node has designed the PDS Spectral Library Data Dictionary, which contains PDS4 classes and attributes specifically for labeling spectral data, including a classification scheme for samples. The Reflectance Experiment Laboratory (RELAB) at Brown University, which has long been a provider of spectroscopy equipment and services to the science community, has provided expert input into the design of the dictionary. Together the Geosciences Node and RELAB are preparing the whole of the RELAB Spectral Library, consisting of many thousands of spectra collected over the years, to be archived in PDS. An online interface for searching, displaying, and downloading selected spectra is planned, using the Spectral Library metadata recorded in the PDS labels. The data dictionary and online interface will be extended to include spectral libraries submitted by other data providers. The Spectral Library Data Dictionary is now available from PDS at https://pds.nasa.gov/pds4/schema/released/. It can be used in PDS4 labels for reflectance spectra as well as for Raman, XRF, XRD, LIBS, and other types of spectra. Ancillary data such as images, chemistry, and abundance data are also supported. To help generate PDS4-compliant labels for spectra, the Geosciences Node provides a label generation program called MakeLabels (http://pds-geosciences.wustl.edu/tools/makelabels.html) which creates labels from a template, and which can be used for any kind of PDS4 label. For information, contact the Geosciences Node at geosci@wunder.wustl.edu.

  19. (reprocessed)HeliscopeCAGE sequencing, Delve mapping and CAGE TSS aggregation - FANTOM5 | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us FANTOM...ntified by CAGE tag analysis (BED format) *.rdna.fa.gz: rDNA sequences (FASTA format) Data file File name: fantom...5_rp_exp_details.zip File URL: ftp://ftp.biosciencedbc.jp/archive/fantom5/20161221/fantom5_rp_exp_detai...tp://ftp.biosciencedbc.jp/archive/fantom5/datafiles/reprocessed/hg38_latest/basic/ File size: 1.4 TB File na...me: (reprocessed)basic (Mus musculus) File URL: ftp://ftp.biosciencedbc.jp/archive/fantom5/datafiles/reproce

  20. EPICS data archiver at SSRF beamlines

    International Nuclear Information System (INIS)

    Hu Zheng; Mi Qingru; Zheng Lifang; Li Zhong

    2014-01-01

    The control system of SSRF (Shanghai Synchrotron Radiation Facility) is based on EPICS (Experimental Physics and Industrial Control System). Operation data storage for synchrotron radiation facility is important for its status monitoring and analysis. At SSRF, operation data used to be index files recorded by traditional EPICS Channel Archiver. Nevertheless, index files are not suitable for long-term maintenance and difficult for data analysis. Now, RDB Channel Archiver and MySQL are used for SSRF beamline operation data archiving, so as to promote the data storage reliability and usability. By applying a new uploading mechanism to RDB Channel Archiver, its writing performance is improved. A web-based GUI (Graphics User Interface) is also developed to make it easier to access database. (authors)

  1. Old and New Archives

    Directory of Open Access Journals (Sweden)

    Ioana Vasiloiu

    2015-01-01

    Full Text Available Library and museum archives are real testimony of collective memory. Old or new, their "universe" is fascinating. They are the path to an almost forgotten world with all its cultural and intellectual problems or allow us to reconsider the social, historical, political and cultural present. The inestimable value of their manuscripts, books and periodicals made medieval Romanian library archives to be famous in that age. Its content figured out the Romanian humanist's vast intellectual activity and their connection to European values. Their remains, which can be found today especially at Romanian Academy Library, depict some aspects of Romanian medieval cultural life. Particularly, with its huge number of manuscripts, books and periodicals, the National Romanian Literature Museum archives contribute to Romanian history reconstruction from the commencement to present.

  2. Archival claims in Southern Africa | Mnjama | Innovation

    African Journals Online (AJOL)

    The author examines the problem of archival claims in the region. He begins by defining the broad categories of archives that fall under the rubric of `migrated archives' and shows that virtually all states in the region are affected by problems related to this phenomenon. He argues that failure to distinguish the different ...

  3. Comparative study of the characteristics of some suction devices for gas sampling applications; Etude comparative des caracteristiques de quelques dispositifs d'aspiration a l'usage des prelevements de gaz

    Energy Technology Data Exchange (ETDEWEB)

    Donguy, R.; Drouet, J.

    1959-06-15

    Gas sampling (used to determine the characteristics of dusts or aerosols contained in a gas) needs a suction device. In order to select the right device and the right conditions of use, the characteristics and performances of various suction devices (helicoidal and centrifugal aspirators, air pumps, volumetric pumps) have been experimentally measured: flow rate, head loss, sampling volume and duration, aerosol and dust concentration, gas density, nature of the gas, suction circuit configuration, etc.

  4. Un cinéma palestinien « en mal d’archive » The “Archive Fever” of Palestinian Cinema

    Directory of Open Access Journals (Sweden)

    Laure Fourest

    2012-05-01

    Full Text Available À partir de l’analyse de trois films palestiniens réalisés dans les années 2000, cet article propose d’interroger l’insertion d’images d’archives par les cinéastes dans leur montage : quelles stratégies mettent-ils en œuvre et à quelles fins ? Qu’apportent des images d’archives en plus des témoignages filmés ? Comment le recours à ces images permet-il de participer au débat historiographique qui sous-tend et détermine en partie le conflit israélo-palestinien ? Dans le contexte palestinien où il n’existe pas d’institution archivistique officielle, les archives sont porteuses d’enjeux particulièrement saillants, donnant lieu à un véritable « mal d’archive ». Celui-ci fait naître une multiplicité de stratégies cinématographiques visant à questionner cette zone d’inconfort, où le maniement des qualités émotionnelles et sensorielles de l’archive peut être un moyen de faire preuve.Through the analysis of three Palestinian films created in the 2000-2010 period, this article considers filmmakers’ insertion of archival images in their montages: what strategies do they employ and for what purpose? What do archival images add to filmed testimony? How does the use of these images enable participation in the historiographical debate underlying and partly determining the Israel-Palestine conflict? In the Palestinian context, where no official archive institution exists, archives entail particularly salient issues, making their lack truly sore. This generates a multiplicity of cinematographic strategies aiming to challenge this discomfort zone, where the manipulation of the emotional and sensorial qualities of archives can be a means of proving something.

  5. Evaluation of continued storage of samples at the 325 Laboratory

    International Nuclear Information System (INIS)

    McVey, C.B.

    1996-01-01

    This report provides identification of potential Program users for samples that are archived at Pacific Northwest National Laboratory (PNNL) facilities, establishes cost releated to packaging and transportation of these samples to 222-S, for continued storage at 325 facilities, disposal and transfer costs. The report provides a recommendation to dispose of 20 samples, transfer 99 samples to PNNL and to continue storage of the remaining samples at PNNL's 325 facility

  6. Update History of This Database - PSCDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available List Contact us PSCDB Update History of This Database Date Update contents 2016/11/30 PSCDB English archive ...site is opened. 2011/11/13 PSCDB ( http://idp1.force.cs.is.nagoya-u.ac.jp/pscdb/ ) is opened. About This Database Database... Description Download License Update History of This Database Site Policy | Contact Us Update History of This Database - PSCDB | LSDB Archive ...

  7. Catch me if you can: Comparing ballast water sampling skids to traditional net sampling

    Science.gov (United States)

    Bradie, Johanna; Gianoli, Claudio; Linley, Robert Dallas; Schillak, Lothar; Schneider, Gerd; Stehouwer, Peter; Bailey, Sarah

    2018-03-01

    With the recent ratification of the International Convention for the Control and Management of Ships' Ballast Water and Sediments, 2004, it will soon be necessary to assess ships for compliance with ballast water discharge standards. Sampling skids that allow the efficient collection of ballast water samples in a compact space have been developed for this purpose. We ran 22 trials on board the RV Meteor from June 4-15, 2015 to evaluate the performance of three ballast water sampling devices (traditional plankton net, Triton sampling skid, SGS sampling skid) for three organism size classes: ≥ 50 μm, ≥ 10 μm to Natural sea water was run through the ballast water system and untreated samples were collected using paired sampling devices. Collected samples were analyzed in parallel by multiple analysts using several different analytic methods to quantify organism concentrations. To determine whether there were differences in the number of viable organisms collected across sampling devices, results were standardized and statistically treated to filter out other sources of variability, resulting in an outcome variable representing the mean difference in measurements that can be attributed to sampling devices. These results were tested for significance using pairwise Tukey contrasts. Differences in organism concentrations were found in 50% of comparisons between sampling skids and the plankton net for ≥ 50 μm, and ≥ 10 μm to < 50 μm size classes, with net samples containing either higher or lower densities. There were no differences for < 10 μm organisms. Future work will be required to explicitly examine the potential effects of flow velocity, sampling duration, sampled volume, and organism concentrations on sampling device performance.

  8. 21 CFR 868.1100 - Arterial blood sampling kit.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...

  9. Art from Archives: The Archival Trend in Contemporary Art and Culture

    Directory of Open Access Journals (Sweden)

    Martyn Jolly

    2014-12-01

    Full Text Available If the archival mode has been important over the last thirty years, it will only continue to become more important in the next thirty years. In the fifteen years since Lev Manovich wrote The Language of New Media, in which he identified the database with its operations of searching navigating and viewing as the new-media correlate to the novel and cinema with their operations of narrative storytelling, databases have only increased in scale, complexity and ubiquity — at an exponential rate, as is the case with all technologies. Archives are being uncovered or created at an unprecedented rate, digitized at an unprecedented rate and made searchable at an unprecedented rate. New ways of interrogating the archive, new ways of searching metadata and new ways of presenting iterations from the archive, such as more complex data visualizations, are being developed. At the same time photographs are manifesting themselves in a wider range of material substances — etched in stone or glass, printed on cloth or metal, projected on walls and buildings, and sliding along LED arrays or screens. But the story isn’t all about the seductions of new media. The more artists and historians work in this area, the more they realize that there are still troves and troves of objects and images, laid down in all their recalcitrant materiality by those who came before, just waiting to be rediscovered and reinvented.

  10. Profiles of international archives: Les archives Jean Piaget, University of Geneva, Switzerland.

    Science.gov (United States)

    Burman, Jeremy Trevelyan

    2013-05-01

    This research report provides a look behind closed doors at the Jean Piaget Archives in Geneva, Switzerland. It situates the potential visitor, contextualizes the Archives in its own history, and then describes what scholars can expect to find. New details about Piaget's views on Equal Rights and Equal Pay are also provided, including a look at how they affected the women who worked his factory (esp. Bärbel Inhelder). (PsycINFO Database Record (c) 2013 APA, all rights reserved).

  11. THE LA PALMA DATA ARCHIVE

    NARCIS (Netherlands)

    ZUIDERWIJK, EJ; MARTIN, R; RAIMOND, E; VANDIEPEN, GNJ

    The operation of the La Palma Data Archive is described in detail. The archive contains data taken since early 1986 with the Isaac Newton Group; 74% of the 260,000 entries are of astronomical sources. Several hundreds of queries are made on the catalog each year, resulting in approximately one

  12. 36 CFR 1280.66 - May I use the National Archives Library?

    Science.gov (United States)

    2010-07-01

    ... Archives Library? 1280.66 Section 1280.66 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS... the Washington, DC, Area? § 1280.66 May I use the National Archives Library? The National Archives Library facilities in the National Archives Building and in the National Archives at College Park are...

  13. Tango archiving service status

    International Nuclear Information System (INIS)

    Abeille, G.; Pierre-Joseph, S.; Guyot, J.; Ounsy, M.; Rubio, S.; Strangolino, G.; Passuello, R.

    2012-01-01

    In modern scientific instruments like ALBA, ELLETRA or Synchrotron Soleil, the monitoring and tuning of thousands of parameters is essential to drive high-performing accelerators and beamlines. To keep track of these parameters and to easily manage large volumes of technical data, an archiving service is a key component of a modern control system like Tango. To achieve this, a high-available archiving service is provided as a feature of the Tango control system. This archiving service stores data coming from the Tango control system into MySQL or Oracle databases. Tree sub-services are provided: 1) An historical service with an archiving period up to 10 seconds; 2) A short term service providing a few weeks retention with a period up to 100 milliseconds; and 3) A snapshot service which takes 'snapshots' of Tango parameters and can reapply them to the control system on user demand. This paper presents how to obtain a high-performance and scalable service based on our feedback after several years of operation. The deployment architecture in the different Tango institutes will then be detailed. The paper concludes with a description of the next steps and incoming features which will be available in the next future. (authors)

  14. NASA Data Archive Evaluation

    Science.gov (United States)

    Holley, Daniel C.; Haight, Kyle G.; Lindstrom, Ted

    1997-01-01

    The purpose of this study was to expose a range of naive individuals to the NASA Data Archive and to obtain feedback from them, with the goal of learning how useful people with varied backgrounds would find the Archive for research and other purposes. We processed 36 subjects in four experimental categories, designated in this report as C+R+, C+R-, C-R+ and C-R-, for computer experienced researchers, computer experienced non-researchers, non-computer experienced researchers, and non-computer experienced non-researchers, respectively. This report includes an assessment of general patterns of subject responses to the various aspects of the NASA Data Archive. Some of the aspects examined were interface-oriented, addressing such issues as whether the subject was able to locate information, figure out how to perform desired information retrieval tasks, etc. Other aspects were content-related. In doing these assessments, answers given to different questions were sometimes combined. This practice reflects the tendency of the subjects to provide answers expressing their experiences across question boundaries. Patterns of response are cross-examined by subject category in order to bring out deeper understandings of why subjects reacted the way they did to the archive. After the general assessment, there will be a more extensive summary of the replies received from the test subjects.

  15. Enabling optical metrology on small 5×5μm2 in-cell targets to support flexible sampling and higher order overlay and CD control for advanced logic devices nodes

    Science.gov (United States)

    Salerno, Antonio; de la Fuente, Isabel; Hsu, Zack; Tai, Alan; Chang, Hammer; McNamara, Elliott; Cramer, Hugo; Li, Daoping

    2018-03-01

    In next generation Logic devices, overlay control requirements shrink to sub 2.5nm level on-product overlay. Historically on-product overlay has been defined by the overlay capability of after-develop in-scribe targets. However, due to design and dimension, the after development metrology targets are not completely representative for the final overlay of the device. In addition, they are confined to the scribe-lane area, which limits the sampling possibilities. To address these two issues, metrology on structures matching the device structure and which can be sampled with high density across the device is required. Conventional after-etch CDSEM techniques on logic devices present difficulties in discerning the layers of interest, potential destructive charging effects and finally, they are limited by the long measurement times[1] [2] [3] . All together, limit the sampling densities and making CDSEM less attractive for control applications. Optical metrology can overcome most of these limitations. Such measurement, however, does require repetitive structures. This requirement is not fulfilled by logic devices, as the features vary in pitch and CD over the exposure field. The solution is to use small targets, with a maximum pad size of 5x5um2 , which can easily be placed in the logic cell area. These targets share the process and architecture of the device features of interest, but with a modified design that replicates as close as possible the device layout, allowing for in-device metrology for both CD and Overlay. This solution enables measuring closer to the actual product feature location and, not being limited to scribe-lanes, it opens the possibility of higher-density sampling schemes across the field. In summary, these targets become the facilitator of in-device metrology (IDM), that is, enabling the measurements both in-device Overlay and the CD parameters of interest and can deliver accurate, high-throughput, dense and after-etch measurements for Logic

  16. Development and implementation of ultrasound picture archiving and communication system

    Science.gov (United States)

    Weinberg, Wolfram S.; Tessler, Franklin N.; Grant, Edward G.; Kangarloo, Hooshang; Huang, H. K.

    1990-08-01

    The Department of Radiological Sciences at the UCLA School of Medicine is developing an archiving and communication system (PACS) for digitized ultrasound images. In its final stage the system will involve the acquisition and archiving of ultrasound studies from four different locations including the Center for Health Sciences, the Department for Mental Health and the Outpatient Radiology and Endoscopy Departments with a total of 200-250 patient studies per week. The concept comprises two stages of image manipulation for each ultrasound work area. The first station is located close to the examination site and accomodates the acquisition of digital images from up to five ultrasound devices and provides for instantaneous display and primary viewing and image selection. Completed patient studies are transferred to a main workstation for secondary review, further analysis and comparison studies. The review station has an on-line storage capacity of 10,000 images with a resolution of 512x512 8 bit data to allow for immediate retrieval of active patient studies of up to two weeks. The main work stations are connected through the general network and use one central archive for long term storage and a film printer for hardcopy output. First phase development efforts concentrate on the implementation and testing of a system at one location consisting of a number of ultrasound units with video digitizer and network interfaces and a microcomputer workstation as host for the display station with two color monitors, each allowing simultaneous display of four 512x512 images. The discussion emphasizes functionality, performance and acceptance of the system in the clinical environment.

  17. Donors and archives a guidebook for successful programs

    CERN Document Server

    Purcell, Aaron D

    2015-01-01

    Donors and Archives: A Guidebook for Successful Programs highlights the importance of development and fundraising for archives, while focusing on the donor and potential donor. Their interest, their support, their enthusiasm, and their stuff are vital to the success of archival programs.

  18. Discussion the exploitation of nuclear power archival resources

    International Nuclear Information System (INIS)

    Fan Fei

    2012-01-01

    In recent years with the development of government policy on nuclear power by the 'proper development' to 'positive rapid development', the nuclear power stations have mushroomed. As an important part of nuclear power plant the archives plays an important role in ensuring the safe and stable operation. With the increasing nuclear power archival resources, its how the rational and efficient development and utilization of nuclear power as an important corporate archivists subject. Nuclear power archives is no longer a static file 'archive' but a steady steam of out knowledge and wisdom of the 'think tank', 'treasure', our archives staff also no longer simply a medium used to provide lending, but to provide reference 'experts' and 'think tank'. Based on the analysis of nuclear features of archival resources, the use of a new perspective on nuclear power development and utilization of enterprise file made bold attempts and innovation. (author)

  19. Research Groups & Research Subjects - RED | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available rch Groups & Research Subjects Data detail Data name Research Groups & Research Sub... Number of data entries 174 entries Data item Description Research ID Research ID (Subject number) Institute...tion Download License Update History of This Database Site Policy | Contact Us Research Groups & Research Subjects - RED | LSDB Archive ... ...switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us RED Resea... Organization Section Section (Department) User name User name Experimental title Experimental title (Rese

  20. Wideband 4-diode sampling circuit

    Science.gov (United States)

    Wojtulewicz, Andrzej; Radtke, Maciej

    2016-09-01

    The objective of this work was to develop a wide-band sampling circuit. The device should have the ability to collect samples of a very fast signal applied to its input, strengthen it and prepare for further processing. The study emphasizes the method of sampling pulse shaping. The use of ultrafast pulse generator allows sampling signals with a wide frequency spectrum, reaching several gigahertzes. The device uses a pulse transformer to prepare symmetrical pulses. Their final shape is formed with the help of the step recovery diode, two coplanar strips and Schottky diode. Made device can be used in the sampling oscilloscope, as well as other measurement system.

  1. Data processing device

    International Nuclear Information System (INIS)

    Kita, Yoshio.

    1994-01-01

    A data processing device for use in a thermonuclear testing device comprises a frequency component judging section for analog signals, a sample time selection section based on the result of the judgement, a storing memory section for selecting digital data memorized in the sampling time. Namely, the frequency components of the analog signals are detected by the frequency component judging section, and one of a plurality of previously set sampling times is selected by the sampling time selection section based on the result of the judgement of the frequency component judging section. Then, digital data obtained by A/D conversion are read and preliminarily memorized in the storing memory section. Subsequently, the digital data memorized in the sampling time selected by the sampling time selection section are selected and transmitted to a superior computer. The amount of data to be memorized can greatly reduced, to reduce the cost. (N.H.)

  2. NASA's Long-Term Astrophysics Data Archives

    OpenAIRE

    Rebull, L. M.; Desai, V.; Teplitz, H.; Groom, S.; Akeson, R.; Berriman, G. B.; Helou, G.; Imel, D.; Mazzarella, J. M.; Accomazzi, A.; McGlynn, T.; Smale, A.; White, R.

    2017-01-01

    NASA regards data handling and archiving as an integral part of space missions, and has a strong track record of serving astrophysics data to the public, beginning with the the IRAS satellite in 1983. Archives enable a major science return on the significant investment required to develop a space mission. In fact, the presence and accessibility of an archive can more than double the number of papers resulting from the data. In order for the community to be able to use the data, they have to b...

  3. Archival Discipline in Dewey Decimal Classification

    Directory of Open Access Journals (Sweden)

    Laura Manzoni

    2017-05-01

    Full Text Available This paper regards the ways archival discipline is treated in DDC. After a short introduction about the discipline in Italy, the essay focuses on the analysis of division 020 of DDC 23, with specific attention to section 025 and with punctual reference to section 651, concerning archival material. The aim of the paper is to point out archival discipline’s peculiarities and its differences from library science, as well as underlining the critical issues on how this discipline is handled in DDC.

  4. Assessment of the potential respiratory hazard of volcanic ash from future Icelandic eruptions: A study of archived basaltic to rhyolitic ash samples

    Science.gov (United States)

    Damby, David; Horwell, Claire J.; Larsen, Gudrun; Thordarson, Thorvaldur; Tomatis, Maura; Fubini, Bice; Donaldson, Ken

    2017-01-01

    BackgroundThe eruptions of Eyjafjallajökull (2010) and Grímsvötn (2011), Iceland, triggered immediate, international consideration of the respiratory health hazard of inhaling volcanic ash, and prompted the need to estimate the potential hazard posed by future eruptions of Iceland’s volcanoes to Icelandic and Northern European populations. MethodsA physicochemical characterization and toxicological assessment was conducted on a suite of archived ash samples spanning the spectrum of past eruptions (basaltic to rhyolitic magmatic composition) of Icelandic volcanoes following a protocol specifically designed by the International Volcanic Health Hazard Network. ResultsIcelandic ash can be of a respirable size (up to 11.3 vol.% < 4 μm), but the samples did not display physicochemical characteristics of pathogenic particulate in terms of composition or morphology. Ash particles were generally angular, being composed of fragmented glass and crystals. Few fiber-like particles were observed, but those present comprised glass or sodium oxides, and are not related to pathogenic natural fibers, like asbestos or fibrous zeolites, thereby limiting concern of associated respiratory diseases. None of the samples contained cristobalite or tridymite, and only one sample contained quartz, minerals of interest due to the potential to cause silicosis. Sample surface areas are low, ranging from 0.4 to 1.6 m2 g−1, which aligns with analyses on ash from other eruptions worldwide. All samples generated a low level of hydroxyl radicals (HO•), a measure of surface reactivity, through the iron-catalyzed Fenton reaction compared to concurrently analyzed comparative samples. However, radical generation increased after ‘refreshing’ sample surfaces, indicating that newly erupted samples may display higher reactivity. A composition-dependent range of available surface iron was measured after a 7-day incubation, from 22.5 to 315.7 μmol m−2, with mafic samples releasing more iron

  5. The use of gamma ray computed tomography to investigate soil compaction due to core sampling devices

    International Nuclear Information System (INIS)

    Pires, Luiz F.; Arthur, Robson C.J.; Correchel, Vladia; Bacchi, Osny O.S.; Reichardt, Klaus; Brasil, Rene P. Camponez do

    2004-01-01

    Compaction processes can influence soil physical properties such as soil density, porosity, pore size distribution, and processes like soil water and nutrient movements, root system distribution, and others. Soil porosity modification has important consequences like alterations in results of soil water retention curves. These alterations may cause differences in soil water storage calculations and matrix potential values, which are utilized in irrigation management systems. Because of this, soil-sampling techniques should avoid alterations of sample structure. In this work soil sample compaction caused by core sampling devices was investigated using the gamma ray computed tomography technique. A first generation tomograph with fixed source-detector arrangement and translation/rotational movements of the sample was utilized to obtain the images. The radioactive source is 241 Am, with an activity of 3.7 GBq, and the detector consists of a 3 in. x 3 in. NaI(Tl) scintillation crystal coupled to a photomultiplier tube. Soil samples were taken from an experimental field utilizing cylinders 4.0 cm high and 2.6 cm in diameter. Based on image analyses it was possible to detect compacted regions in all samples next to the cylinder wall due to the sampling system. Tomographic unit profiles of the sample permitted to identify higher values of soil density for deeper regions of the sample, and it was possible to determine the average densities and thickness of these layers. Tomographic analyses showed to be a very useful tool for soil compaction characterization and presented many advantages in relation to traditional methods. (author)

  6. Life Sciences Data Archive (LSDA)

    Science.gov (United States)

    Fitts, M.; Johnson-Throop, Kathy; Thomas, D.; Shackelford, K.

    2008-01-01

    In the early days of spaceflight, space life sciences data were been collected and stored in numerous databases, formats, media-types and geographical locations. While serving the needs of individual research teams, these data were largely unknown/unavailable to the scientific community at large. As a result, the Space Act of 1958 and the Science Data Management Policy mandated that research data collected by the National Aeronautics and Space Administration be made available to the science community at large. The Biomedical Informatics and Health Care Systems Branch of the Space Life Sciences Directorate at JSC and the Data Archive Project at ARC, with funding from the Human Research Program through the Exploration Medical Capability Element, are fulfilling these requirements through the systematic population of the Life Sciences Data Archive. This program constitutes a formal system for the acquisition, archival and distribution of data for Life Sciences-sponsored experiments and investigations. The general goal of the archive is to acquire, preserve, and distribute these data using a variety of media which are accessible and responsive to inquiries from the science communities.

  7. Interface requirements in nuclear medicine devices and systems

    International Nuclear Information System (INIS)

    Maguire, G.Q. Jr.; Brill, A.B.; Noz, M.E.

    1982-01-01

    Interface designs for three nuclear medicine imaging systems, and computer networking strategies proposed for medical imaging departments are presented. Configurations for two positron-emission-tomography devices (PET III and ECAT) and a general-purpose tomography instrument (the UNICON) are analyzed in terms of specific performance parameters. Interface designs for these machines are contrasted in terms of utilization of standard versus custom modules, cost, and ease of modification, upgrade, and support. The requirements of general purpose systems for medical image analysis, display, and archiving, are considered, and a realizable state-of-the-art system is specfied, including a suggested timetable

  8. Studio Constructing an Archive - Modelkabinettet

    DEFF Research Database (Denmark)

    2012-01-01

    . This has, among other subjects, included an analysis of the architectural exhibition "OMA Progress" at the Barbican Arts Centre in London as well as OMA's architecture, design strategy and media usage. The study has been based on discussions of archives, collections and architecture exhibitions as cultural...... products, historiography, media and architectural representation. Based on the above studies, the students have developed their own projects, which reflect in a critical manner on exhibitions, archives and collections. In Studio Constructing an Archive we focus on architectural representation and its...... significance and influence on the development of architecture and our understanding of architecture. During the spring semester, we have, in particular, been discussing the model and its media characteristics....

  9. Archival services and technologies for scientific data

    International Nuclear Information System (INIS)

    Meyer, Jörg; Hardt, Marcus; Streit, Achim; Wezel, Jos van

    2014-01-01

    After analysis and publication, there is no need to keep experimental data online on spinning disks. For reliability and costs inactive data is moved to tape and put into a data archive. The data archive must provide reliable access for at least ten years following a recommendation of the German Science Foundation (DFG), but many scientific communities wish to keep data available much longer. Data archival is on the one hand purely a bit preservation activity in order to ensure the bits read are the same as those written years before. On the other hand enough information must be archived to be able to use and interpret the content of the data. The latter is depending on many also community specific factors and remains an areas of much debate among archival specialists. The paper describes the current practice of archival and bit preservation in use for different science communities at KIT for which a combination of organizational services and technical tools are required. The special monitoring to detect tape related errors, the software infrastructure in use as well as the service certification are discussed. Plans and developments at KIT also in the context of the Large Scale Data Management and Analysis (LSDMA) project are presented. The technical advantages of the T10 SCSI Stream Commands (SSC-4) and the Linear Tape File System (LTFS) will have a profound impact on future long term archival of large data sets.

  10. Archival Services and Technologies for Scientific Data

    Science.gov (United States)

    Meyer, Jörg; Hardt, Marcus; Streit, Achim; van Wezel, Jos

    2014-06-01

    After analysis and publication, there is no need to keep experimental data online on spinning disks. For reliability and costs inactive data is moved to tape and put into a data archive. The data archive must provide reliable access for at least ten years following a recommendation of the German Science Foundation (DFG), but many scientific communities wish to keep data available much longer. Data archival is on the one hand purely a bit preservation activity in order to ensure the bits read are the same as those written years before. On the other hand enough information must be archived to be able to use and interpret the content of the data. The latter is depending on many also community specific factors and remains an areas of much debate among archival specialists. The paper describes the current practice of archival and bit preservation in use for different science communities at KIT for which a combination of organizational services and technical tools are required. The special monitoring to detect tape related errors, the software infrastructure in use as well as the service certification are discussed. Plans and developments at KIT also in the context of the Large Scale Data Management and Analysis (LSDMA) project are presented. The technical advantages of the T10 SCSI Stream Commands (SSC-4) and the Linear Tape File System (LTFS) will have a profound impact on future long term archival of large data sets.

  11. Archives and societal provenance Australian essays

    CERN Document Server

    Piggott, Michael

    2012-01-01

    Records and archival arrangements in Australia are globally relevant because Australia's indigenous people represent the oldest living culture in the world, and because modern Australia is an ex-colonial society now heavily multicultural in outlook. Archives and Societal Provenance explores this distinctiveness using the theoretical concept of societal provenance as propounded by Canadian archival scholars led by Dr Tom Nesmith. The book's seventeen essays blend new writing and re-workings of earlier work, comprising the fi rst text to apply a societal provenance perspective to a national sett

  12. Sample Set (SE): SE57 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available etabolite accumulation patterns in plants We optimized the MRM conditions for specifi c compounds by performing automate...applied to high-throughput automated analysis of biological samples using TQMS coupled with ultra performanc...ies, and family-specifi c metabolites could be predicted using a batch-learning self organizing map analysis. Thus, the automate

  13. State of art data acquisition system for large volume plasma device

    International Nuclear Information System (INIS)

    Sugandhi, Ritesh; Srivastava, Pankaj; Sanyasi, Amulya Kumar; Srivastav, Prabhakar; Awasthi, Lalit Mohan; Mattoo, Shiban Krishna; Parmar, Vijay; Makadia, Keyur; Patel, Ishan; Shah, Sandeep

    2015-01-01

    The Large volume plasma device (LVPD) is a cylindrical device (ϕ = 2m, L = 3m) dedicated for carrying out investigations on plasma physics problems ranging from excitation of whistler structures to plasma turbulence especially, exploring the linear and nonlinear aspects of electron temperature gradient(ETG) driven turbulence, plasma transport over the entire cross section of LVPD. The machine operates in a pulsed mode with repetition cycle of 1 Hz and acquisition pulse length of duration of 15 ms, presently, LVPD has VXI data acquisition system but this is now in phasing out mode because of non-functioning of its various amplifier stages, expandability and unavailability of service support. The VXI system has limited capabilities to meet new experimental requirements in terms of numbers of channel (16), bit resolutions (8 bit), record length (30K points) and calibration support. Recently, integration of new acquisition system for simultaneous sampling of 40 channels of data, collected over multiple time scales with high speed is successfully demonstrated, by configuring latest available hardware and in-house developed software solutions. The operational feasibility provided by LabVIEW platform is not only for operating DAQ system but also for providing controls to various subsystems associated with the device. The new system is based on PXI express instrumentation bus and supersedes the existing VXI based data acquisition system in terms of instrumentation capabilities. This system has capability to measure 32 signals at 60 MHz sampling frequency and 8 signals with 1.25 GHz with 10 bit and 12 bit resolution capability for amplitude measurements. The PXI based system successfully addresses and demonstrate the issues concerning high channel count, high speed data streaming and multiple I/O modules synchronization. The system consists of chassis (NI 1085), 4 high sampling digitizers (NI 5105), 2 very high sampling digitizers (NI 5162), data streaming RAID drive (NI

  14. Infrastructural challenges on archives and recordkeeping at the ...

    African Journals Online (AJOL)

    ... immediate attention. Given the importance of the national memory in the form of archives or records, the paper recommends that records and archival infrastructural issues be given due attention by both the government and the National Archives of Zimbabwe itself in order to ensure sound records management practices.

  15. Iterating archival footage and the memory of war

    NARCIS (Netherlands)

    Noordegraaf, J.; Bordina, A.; Campanini, S.; Mariani, A.

    2012-01-01

    In this article I focus on the archive as a specific site of memory, in particular the audiovisual archive. I investigate the use of audiovisual archival records as sources for remembering war, specifically the war in the former Yugoslavia (1991-1995). I do so by discussing one particular case

  16. 'Histoire(s du cinema': the Archive of the Century. Warburgian Insights About History

    Directory of Open Access Journals (Sweden)

    Natalia Taccetta

    2015-07-01

    Full Text Available Contemporary to the emergence of video first, and to digital culture later, Jean-Luc Godard profaned hegemonic historiography by using film history to rewrite his own history of the century. In the eight deliveries of Histoire(s du cinéma (1988-1998, Godard articulates a film archive notion that tries to deconstruct conventional representations of the past. Similarly, in his atlas Mnemosyne Aby Warburg proposes a history of art writing that escapes to the chrono-normativity of XIX century historiography. The combined reading of these perspectives allows us to reevaluate the premise on which the archive is both a starting point and a destination for contemporary (audiovisual writing. Indeed, they can be thought of as counter-models of historiographical writing that value the heuristic power of the image to apprehend the past and fight against conventional insights about it. In the light of these considerations, this paper aims to investigate these devices as an array of different ways of thinking about the relationship between cinema and history.

  17. A comprehensive cost model for NASA data archiving

    Science.gov (United States)

    Green, J. L.; Klenk, K. F.; Treinish, L. A.

    1990-01-01

    A simple archive cost model has been developed to help predict NASA's archiving costs. The model covers data management activities from the beginning of the mission through launch, acquisition, and support of retrospective users by the long-term archive; it is capable of determining the life cycle costs for archived data depending on how the data need to be managed to meet user requirements. The model, which currently contains 48 equations with a menu-driven user interface, is available for use on an IBM PC or AT.

  18. EAC Working Group for Archaeological Archives, A European View of Selecting for Archaeological Archives

    Directory of Open Access Journals (Sweden)

    Brown, Duncan H.

    2017-12-01

    Full Text Available This paper examines the issues around selecting for archaeological archives, including the reasons for doing so, how selection fit into a project and the methodological framework. The context is ‘Making Choices’, a project of the Europae Archaeologiae Consilium that is looking at how all choices are made across archaeological practice, while the foundations are provided by existing standards for archiving and for selection.

  19. A new archival infrastructure for highly-structured astronomical data

    Science.gov (United States)

    Dovgan, Erik; Knapic, Cristina; Sponza, Massimo; Smareglia, Riccardo

    2018-03-01

    With the advent of the 2020 Radio Astronomy Telescopes era, the amount and format of the radioastronomical data is becoming a massive and performance-critical challenge. Such an evolution of data models and data formats require new data archiving techniques that allow massive and fast storage of data that are at the same time also efficiently processed. A useful expertise for efficient archiviation has been obtained through data archiving of Medicina and Noto Radio Telescopes. The presented archival infrastructure named the Radio Archive stores and handles various formats, such as FITS, MBFITS, and VLBI's XML, which includes description and ancillary files. The modeling and architecture of the archive fulfill all the requirements of both data persistence and easy data discovery and exploitation. The presented archive already complies with the Virtual Observatory directives, therefore future service implementations will also be VO compliant. This article presents the Radio Archive services and tools, from the data acquisition to the end-user data utilization.

  20. Study of measurement of the alcohol biomarker phosphatidylethanol (PEth) in dried blood spot (DBS) samples and application of a volumetric DBS device.

    Science.gov (United States)

    Beck, Olof; Kenan Modén, Naama; Seferaj, Sabina; Lenk, Gabriel; Helander, Anders

    2018-04-01

    Phosphatidylethanol (PEth) is a group of phospholipids formed in cell membranes following alcohol consumption. PEth measurement in whole blood samples is established as a specific alcohol biomarker with clinical and medico-legal applications. This study further evaluated the usefulness of dried blood spot (DBS) samples collected on filter paper for PEth measurement. Specimens used were surplus volumes of venous whole blood sent for routine LC-MS/MS quantification of PEth 16:0/18:1, the major PEth homolog. DBS samples were prepared by pipetting blood on Whatman 903 Protein Saver Cards and onto a volumetric DBS device (Capitainer). The imprecision (CV) of the DBS sample amount based on area and weight measurements of spot punches were 23-28%. Investigation of the relationship between blood hematocrit and PEth concentration yielded a linear, positive correlation, and at around 1.0-1.5μmol/L PEth 16:0/18:1, the PEth concentration increased by ~0.1μmol/L for every 5% increase in hematocrit. There was a close agreement between the PEth concentrations obtained with whole blood samples and the corresponding results using Whatman 903 (PEth DBS =1.026 PEth WB +0.013) and volumetric device (PEth DBS =1.045 PEth WB +0.016) DBS samples. The CV of PEth quantification in DBS samples at concentrations≥0.05μmol/L were ≤15%. The present results further confirmed the usefulness of DBS samples for PEth measurement. Copyright © 2018 Elsevier B.V. All rights reserved.