WorldWideScience

Sample records for samples comparable results

  1. Comparability of river suspended-sediment sampling and laboratory analysis methods

    Science.gov (United States)

    Groten, Joel T.; Johnson, Gregory D.

    2018-03-06

    Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.

  2. Comparison of the Multiple-sample means with composite sample results for fecal indicator bacteria by quantitative PCR and culture

    Science.gov (United States)

    ABSTRACT: Few studies have addressed the efficacy of composite sampling for measurement of indicator bacteria by QPCR. In this study, composite results were compared to single sample results for culture- and QPCR-based water quality monitoring. Composite results for both methods ...

  3. A comparative study of general intelligence in Spanish and Moroccan samples.

    Science.gov (United States)

    Diaz, Amelia; Sellami, Khadija; Infanzón, Eugenia; Lanzón, Teresa; Lynn, Richard

    2012-07-01

    The aim of this study is to fill a gap in intelligence research by presenting data for the average IQ in Morocco and for a comparable sample in Spain. Adult samples were administered the Raven Standard Progressive Matrices (SPM) (Raven, Court, & Raven, 2001) and scored for the total test and for the three sub-factors of gestalt continuation, verbal-analytical reasoning and visuospatial ability identified by Lynn, Allik, and Irwing (2004). The total test and the three factors have shown satisfactory reliability. Our results for the Moroccan sample show significant relationship between general intelligence factor, gestalt continuation and visuospatial ability with education level and income. Conversely, these variables have been shown to be independent for the Spanish sample. This sample obtained significantly higher scores for the four factors assessed than the Moroccan one. These differences have been found also comparing samples with the same education levels. Finally, the errors percentage for Moroccans has been higher than for Spaniards in all the items, suggesting that the level of difficulty was higher for the Moroccan sample.

  4. Comparative analysis of vaginal microbiota sampling using 16S rRNA gene analysis.

    Science.gov (United States)

    Virtanen, Seppo; Kalliala, Ilkka; Nieminen, Pekka; Salonen, Anne

    2017-01-01

    Molecular methods such as next-generation sequencing are actively being employed to characterize the vaginal microbiota in health and disease. Previous studies have focused on characterizing the biological variation in the microbiota, and less is known about how factors related to sampling contribute to the results. Our aim was to investigate the impact of a sampling device and anatomical sampling site on the quantitative and qualitative outcomes relevant for vaginal microbiota research. We sampled 10 Finnish women representing diverse clinical characteristics with flocked swabs, the Evalyn® self-sampling device, sterile plastic spatulas and a cervical brush that were used to collect samples from fornix, vaginal wall and cervix. Samples were compared on DNA and protein yield, bacterial load, and microbiota diversity and species composition based on Illumina MiSeq sequencing of the 16S rRNA gene. We quantified the relative contributions of sampling variables versus intrinsic variables in the overall microbiota variation, and evaluated the microbiota profiles using several commonly employed metrics such as alpha and beta diversity as well as abundance of major bacterial genera and species. The total DNA yield was strongly dependent on the sampling device and to a lesser extent on the anatomical site of sampling. The sampling strategy did not affect the protein yield or the bacterial load. All tested sampling methods produced highly comparable microbiota profiles based on MiSeq sequencing. The sampling method explained only 2% (p-value = 0.89) of the overall microbiota variation, markedly surpassed by intrinsic factors such as clinical status (microscopy for bacterial vaginosis 53%, p = 0.0001), bleeding (19%, p = 0.0001), and the variation between subjects (11%, p-value 0.0001). The results indicate that different sampling strategies yield comparable vaginal microbiota composition and diversity. Hence, past and future vaginal microbiota studies employing different

  5. Sample Results From Tank 48H Samples HTF-48-14-158, -159, -169, and -170

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hang, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-04-28

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 48H in support of determining the cause for the unusually high dose rates at the sampling points for this tank. A set of two samples was taken from the quiescent tank, and two additional samples were taken after the contents of the tank were mixed. The results of the analyses of all the samples show that the contents of the tank have changed very little since the analysis of the previous sample in 2012. The solids are almost exclusively composed of tetraphenylborate (TPB) salts, and there is no indication of acceleration in the TPB decomposition. The filtrate composition shows a moderate increase in salt concentration and density, which is attributable to the addition of NaOH for the purposes of corrosion control. An older modeling simulation of the TPB degradation was updated, and the supernate results from a 2012 sample were run in the model. This result was compared to the results from the 2014 recent sample results reported in this document. The model indicates there is no change in the TPB degradation from 2012 to 2014. SRNL measured the buoyancy of the TPB solids in Tank 48H simulant solutions. It was determined that a solution of density 1.279 g/mL (~6.5M sodium) was capable of indefinitely suspending the TPB solids evenly throughout the solution. A solution of density 1.296 g/mL (~7M sodium) caused a significant fraction of the solids to float on the solution surface. As the experiments could not include the effect of additional buoyancy elements such as benzene or hydrogen generation, the buoyancy measurements provide an upper bound estimate of the density in Tank 48H required to float the solids.

  6. An Optimization Study on Listening Experiments to Improve the Comparability of Annoyance Ratings of Noise Samples from Different Experimental Sample Sets.

    Science.gov (United States)

    Di, Guoqing; Lu, Kuanguang; Shi, Xiaofan

    2018-03-08

    Annoyance ratings obtained from listening experiments are widely used in studies on health effect of environmental noise. In listening experiments, participants usually give the annoyance rating of each noise sample according to its relative annoyance degree among all samples in the experimental sample set if there are no reference sound samples, which leads to poor comparability between experimental results obtained from different experimental sample sets. To solve this problem, this study proposed to add several pink noise samples with certain loudness levels into experimental sample sets as reference sound samples. On this basis, the standard curve between logarithmic mean annoyance and loudness level of pink noise was used to calibrate the experimental results and the calibration procedures were described in detail. Furthermore, as a case study, six different types of noise sample sets were selected to conduct listening experiments using this method to examine the applicability of it. Results showed that the differences in the annoyance ratings of each identical noise sample from different experimental sample sets were markedly decreased after calibration. The determination coefficient ( R ²) of linear fitting functions between psychoacoustic annoyance (PA) and mean annoyance (MA) of noise samples from different experimental sample sets increased obviously after calibration. The case study indicated that the method above is applicable to calibrating annoyance ratings obtained from different types of noise sample sets. After calibration, the comparability of annoyance ratings of noise samples from different experimental sample sets can be distinctly improved.

  7. COMPARATIVE STUDY OF ENDOMETRIAL SAMPLING USING PIPELLE WITH HYSTEROSCOPIC-GUIDED BIOPSY

    Directory of Open Access Journals (Sweden)

    Nalina S

    2017-07-01

    Full Text Available BACKGROUND Hysteroscopic-guided biopsy is the gold standard for endometrial sampling, but it carries risk of general anaesthesia, infection and perforation, whereas Pipelle does not require anaesthesia or cervical dilatation and it allows outpatient and painless endometrial sampling. The aim of the study is to determine the reliability and accuracy of Pipelle aspiration in acquiring an adequate and representative endometrial sample and to compare its histopathology with hysteroscopic-directed biopsy. MATERIALS AND METHODS A prospective observational comparative study evaluating the role of Pipelle aspiration as an outpatient procedure in endometrial sampling of perimenopausal women with AUB. 150 perimenopausal women with clinical diagnosis of abnormal uterine bleeding were selected from the Gynaecology OPD of IOG, Chennai, between October 2014 and September 2015. They were subjected to endometrial sampling by Pipelle followed by hysteroscopic-directed biopsy. The efficacy of Pipelle was determined by correlating the histopathological results obtained from it and the hysteroscopic-directed biopsy. RESULTS The histopathology of the endometrium obtained using Pipelle’s curette showed a sensitivity of 93%, specificity of 90% in the detection of abnormal findings with PPV of 88% and NPV of 94%. However, accuracy of Pipelle is found to be less in the diagnosis of polyps and submucous fibroids with accuracy of nearing 100% when using hysteroscopy. CONCLUSION Pipelle endometrial sampling is convenient, easy, painless and safe in obtaining an adequate sample for histopathology with high sensitivity and specificity for endometrial pathologies and endometrial carcinoma.

  8. Sample Results from MCU Solids Outage

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T.; Washington, A.; Oji, L.; Coleman, C.; Poirier, M.

    2014-09-22

    Savannah River National Laboratory (SRNL) has received several solid and liquid samples from MCU in an effort to understand and recover from the system outage starting on April 6, 2014. SRNL concludes that the presence of solids in the Salt Solution Feed Tank (SSFT) is the likely root cause for the outage, based upon the following discoveries: A solids sample from the extraction contactor #1 proved to be mostly sodium oxalate; A solids sample from the scrub contactor#1 proved to be mostly sodium oxalate; A solids sample from the Salt Solution Feed Tank (SSFT) proved to be mostly sodium oxalate; An archived sample from Tank 49H taken last year was shown to contain a fine precipitate of sodium oxalate; A solids sample from ; A liquid sample from the SSFT was shown to have elevated levels of oxalate anion compared to the expected concentration in the feed. Visual inspection of the SSFT indicated the presence of precipitated or transferred solids, which were likely also in the Salt Solution Receipt Tank (SSRT). The presence of the solids coupled with agitation performed to maintain feed temperature resulted in oxalate solids migration through the MCU system and caused hydraulic issues that resulted in unplanned phase carryover from the extraction into the scrub, and ultimately the strip contactors. Not only did this carryover result in the Strip Effluent (SE) being pushed out of waste acceptance specification, but it resulted in the deposition of solids into several of the contactors. At the same time, extensive deposits of aluminosilicates were found in the drain tube in the extraction contactor #1. However it is not known at this time how the aluminosilicate solids are related to the oxalate solids. The solids were successfully cleaned out of the MCU system. However, future consideration must be given to the exclusion of oxalate solids into the MCU system. There were 53 recommendations for improving operations recently identified. Some additional considerations or

  9. Social inclusion of the people with mental health issues: Compare international results.

    Science.gov (United States)

    Santos, Jussara Carvalho Dos; Barros, Sônia; Huxley, Peter John

    2018-06-01

    Social inclusion of people with mental health issues is an aim of the World Health Organisation. Many countries have adopted that objective, including Brazil and the United Kingdom and both have focused treatment in the community. The aim of this article is to compare international results using the same inclusion instrument. The samples in this study were 225 people with mental health issues in community services in São Paulo, Brazil. Their results are compared to findings from 168 people with similar mental health issues in Hong Kong, China, and from the United Kingdom - a nationally representative sample of 212 people without mental health issues. The instrument used to measure a social inclusion called Social and Communities Opportunities Profile (SCOPE) has been validated for use in the United Kingdom, China and Brazil. The results are that people with mental health issues have worse social inclusion when compared to general population. Between the people with mental health issues, the sample of São Paulo has the lowest social inclusion index but, in relation to access to the Brazilian revised mental health services, that sample has a similarly high inclusion rating to the general population of the United Kingdom. Findings are important to understand mental health in the community context, as well as their adversities and potentialities.

  10. Preparation of 45Ca(HDEHP)n and (CaH1502)2 samples for liquid scintillation counting, compared to 45caCl2 results

    International Nuclear Information System (INIS)

    Rodriguez, L.; Arcos, J. M. los; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting organic samples of the Di-2-ethylhexyl phosphate calcium complex and the 2-ethylhexanoate calcium salt, labelled with 45Ca, is described. The chemical quench, the counting stability and spectral evolution of both compounds is studied in six scintillators,Toluene-alcohol, Dioxane-naphtalene, Hi safe II, Ultimate-Gold and Instagel, and compared to results obtained from a commercial solution of 4 5CaCl2. (Author) 7 refs

  11. A comparison of results for samples collected with bailers constructed of different materials

    International Nuclear Information System (INIS)

    Thomey, N.; Ogle, R.; Jackson, J.

    1992-01-01

    A bailer is one of the most common sampling devices used to collect ground water samples. Bailers constructed from various materials are available; teflon, polyvinyl chloride (PVC), polyethylene, and stainless steel are all commonly used. It is widely recognized that sample results can be affected by the material from which the bailer is constructed. Teflon and stainless steel are usually recommended based upon their inert properties. The cost of these bailers is significantly higher than other types. For the purposes of petroleum storage tank investigations, sampling devices that would not compromise sample quality but be more economical than teflon or stainless steel would be especially desirable. Water samples were collected using the different types of bailers; teflon, stainless steel, PVC, and polyethylene. Split samples were analyzed for benzene, toluene, ethylbenzene, total xylenes, and Total Petroleum Hydrocarbons. The analytical results were compared to determine if differences were due to normal analytical variances or due to interaction of the sample with the sampling device. No difference was noted in the results which were obtained

  12. Comparing fixed sampling with minimizer sampling when using k-mer indexes to find maximal exact matches.

    Science.gov (United States)

    Almutairy, Meznah; Torng, Eric

    2018-01-01

    Bioinformatics applications and pipelines increasingly use k-mer indexes to search for similar sequences. The major problem with k-mer indexes is that they require lots of memory. Sampling is often used to reduce index size and query time. Most applications use one of two major types of sampling: fixed sampling and minimizer sampling. It is well known that fixed sampling will produce a smaller index, typically by roughly a factor of two, whereas it is generally assumed that minimizer sampling will produce faster query times since query k-mers can also be sampled. However, no direct comparison of fixed and minimizer sampling has been performed to verify these assumptions. We systematically compare fixed and minimizer sampling using the human genome as our database. We use the resulting k-mer indexes for fixed sampling and minimizer sampling to find all maximal exact matches between our database, the human genome, and three separate query sets, the mouse genome, the chimp genome, and an NGS data set. We reach the following conclusions. First, using larger k-mers reduces query time for both fixed sampling and minimizer sampling at a cost of requiring more space. If we use the same k-mer size for both methods, fixed sampling requires typically half as much space whereas minimizer sampling processes queries only slightly faster. If we are allowed to use any k-mer size for each method, then we can choose a k-mer size such that fixed sampling both uses less space and processes queries faster than minimizer sampling. The reason is that although minimizer sampling is able to sample query k-mers, the number of shared k-mer occurrences that must be processed is much larger for minimizer sampling than fixed sampling. In conclusion, we argue that for any application where each shared k-mer occurrence must be processed, fixed sampling is the right sampling method.

  13. Comparing fixed sampling with minimizer sampling when using k-mer indexes to find maximal exact matches.

    Directory of Open Access Journals (Sweden)

    Meznah Almutairy

    Full Text Available Bioinformatics applications and pipelines increasingly use k-mer indexes to search for similar sequences. The major problem with k-mer indexes is that they require lots of memory. Sampling is often used to reduce index size and query time. Most applications use one of two major types of sampling: fixed sampling and minimizer sampling. It is well known that fixed sampling will produce a smaller index, typically by roughly a factor of two, whereas it is generally assumed that minimizer sampling will produce faster query times since query k-mers can also be sampled. However, no direct comparison of fixed and minimizer sampling has been performed to verify these assumptions. We systematically compare fixed and minimizer sampling using the human genome as our database. We use the resulting k-mer indexes for fixed sampling and minimizer sampling to find all maximal exact matches between our database, the human genome, and three separate query sets, the mouse genome, the chimp genome, and an NGS data set. We reach the following conclusions. First, using larger k-mers reduces query time for both fixed sampling and minimizer sampling at a cost of requiring more space. If we use the same k-mer size for both methods, fixed sampling requires typically half as much space whereas minimizer sampling processes queries only slightly faster. If we are allowed to use any k-mer size for each method, then we can choose a k-mer size such that fixed sampling both uses less space and processes queries faster than minimizer sampling. The reason is that although minimizer sampling is able to sample query k-mers, the number of shared k-mer occurrences that must be processed is much larger for minimizer sampling than fixed sampling. In conclusion, we argue that for any application where each shared k-mer occurrence must be processed, fixed sampling is the right sampling method.

  14. Comparing fixed sampling with minimizer sampling when using k-mer indexes to find maximal exact matches

    Science.gov (United States)

    Torng, Eric

    2018-01-01

    Bioinformatics applications and pipelines increasingly use k-mer indexes to search for similar sequences. The major problem with k-mer indexes is that they require lots of memory. Sampling is often used to reduce index size and query time. Most applications use one of two major types of sampling: fixed sampling and minimizer sampling. It is well known that fixed sampling will produce a smaller index, typically by roughly a factor of two, whereas it is generally assumed that minimizer sampling will produce faster query times since query k-mers can also be sampled. However, no direct comparison of fixed and minimizer sampling has been performed to verify these assumptions. We systematically compare fixed and minimizer sampling using the human genome as our database. We use the resulting k-mer indexes for fixed sampling and minimizer sampling to find all maximal exact matches between our database, the human genome, and three separate query sets, the mouse genome, the chimp genome, and an NGS data set. We reach the following conclusions. First, using larger k-mers reduces query time for both fixed sampling and minimizer sampling at a cost of requiring more space. If we use the same k-mer size for both methods, fixed sampling requires typically half as much space whereas minimizer sampling processes queries only slightly faster. If we are allowed to use any k-mer size for each method, then we can choose a k-mer size such that fixed sampling both uses less space and processes queries faster than minimizer sampling. The reason is that although minimizer sampling is able to sample query k-mers, the number of shared k-mer occurrences that must be processed is much larger for minimizer sampling than fixed sampling. In conclusion, we argue that for any application where each shared k-mer occurrence must be processed, fixed sampling is the right sampling method. PMID:29389989

  15. SEAMIST trademark soil sampling for tritiated water: First year's results

    International Nuclear Information System (INIS)

    Mallon, B.; Martins, S.A.; Houpis, J.L.; Lowry, W.; Cremer, C.D.

    1992-01-01

    SEAMIST trademark is a recently developed sampling system that enables one to measure various soil parameters by means of an inverted, removable, impermeable membrane tube inserted in a borehole. This membrane tube can have various measuring devices installed on it, such as gas ports, adsorbent pads, and electrical sensors. These membrane tubes are made of a laminated polymer. The Lawrence Livermore National Laboratory in Livermore, California, has installed two of these systems to monitor tritium in soil resulting from a leak in an underground storage tank. One tube is equipped with gas ports to sample soil vapor and the other with adsorbent pads to sample soil moisture. Borehole stability was maintained using either sand-filled or air-inflated tubes. Both system implementations yielded concentrations or activities that compared well with the measured concentrations of tritium in the soil taken during borehole construction. In addition, an analysis of the data suggest that both systems prevented the vertical migration of tritium in the boreholes. Also, a neutron probe was successfully used in a blank membrane inserted in one of the boreholes to monitor the moisture in the soil without exposing the probe to the tritium. The neutron log showed excellent agreement with the soil moisture content measured in soil samples taken during borehole construction. This paper describes the two SEAMIST trademark systems used and presents sampling results and comparisons

  16. Statistical Analysis Of Tank 19F Floor Sample Results

    International Nuclear Information System (INIS)

    Harris, S.

    2010-01-01

    Representative sampling has been completed for characterization of the residual material on the floor of Tank 19F as per the statistical sampling plan developed by Harris and Shine. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples results to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL95%) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current scrape sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 19F. The uncertainty is quantified in this report by an UCL95% on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL95% was based entirely on the six current scrape sample results (each averaged across three analytical determinations).

  17. Evaluation of the Correlation Coefficient of Polyethylene Glycol Treated and Direct Prolactin Results and Comparability with Different Assay System Results.

    Science.gov (United States)

    Pal, Shyamali

    2017-12-01

    The presence of Macro prolactin is a significant cause of elevated prolactin resulting in misdiagnosis in all automated systems. Poly ethylene glycol (PEG) pretreatment is the preventive process but such process includes the probability of loss of a fraction of bioactive prolactin. Surprisingly, PEG treated EQAS & IQAS samples in Cobas e 411 are found out to be correlating with direct results of at least 3 immunoassay systems and treated and untreated Cobas e 411 results are comparable by a correlation coefficient. Comparison of EQAS, IQAS and patient samples were done to find out the trueness of such correlation factor. Study with patient's results have established the correlation coefficient is valid for very small concentration of prolactin also. EQAS, IQAS and 150 patient samples were treated with PEG and prolactin results of treated and untreated samples obtained from Roche Cobas e 411. 25 patient's results (treated) were compared with direct results in Advia Centaur, Architect I & Access2 systems. Correlation coefficient was obtained from trend line of the treated and untreated results. Two tailed p-value obtained from regression coefficient(r) and sample size. The correlation coefficient is in the range (0.761-0.771). Reverse correlation range is (1.289-1.301). r value of two sets of calculated results were 0.995. Two tailed p- value is zero approving dismissal of null hypothesis. The z-score of EQAS does not always assure authenticity of resultsPEG precipitation is correlated by the factor 0.761 even in very small concentrationsAbbreviationsGFCgel filtration chromatographyPEGpolyethylene glycolEQASexternal quality assurance systemM-PRLmacro prolactinPRLprolactinECLIAelectro-chemiluminescence immunoassayCLIAclinical laboratory improvement amendmentsIQASinternal quality assurance systemrregression coefficient.

  18. STATISTICAL ANALYSIS OF TANK 18F FLOOR SAMPLE RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Harris, S.

    2010-09-02

    Representative sampling has been completed for characterization of the residual material on the floor of Tank 18F as per the statistical sampling plan developed by Shine [1]. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL [2]. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples results [3] to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL{sub 95%}) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 18F. The uncertainty is quantified in this report by an upper 95% confidence limit (UCL{sub 95%}) on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL{sub 95%} was based entirely on the six current scrape sample results (each averaged across three analytical determinations).

  19. Catch me if you can: Comparing ballast water sampling skids to traditional net sampling

    Science.gov (United States)

    Bradie, Johanna; Gianoli, Claudio; Linley, Robert Dallas; Schillak, Lothar; Schneider, Gerd; Stehouwer, Peter; Bailey, Sarah

    2018-03-01

    With the recent ratification of the International Convention for the Control and Management of Ships' Ballast Water and Sediments, 2004, it will soon be necessary to assess ships for compliance with ballast water discharge standards. Sampling skids that allow the efficient collection of ballast water samples in a compact space have been developed for this purpose. We ran 22 trials on board the RV Meteor from June 4-15, 2015 to evaluate the performance of three ballast water sampling devices (traditional plankton net, Triton sampling skid, SGS sampling skid) for three organism size classes: ≥ 50 μm, ≥ 10 μm to Natural sea water was run through the ballast water system and untreated samples were collected using paired sampling devices. Collected samples were analyzed in parallel by multiple analysts using several different analytic methods to quantify organism concentrations. To determine whether there were differences in the number of viable organisms collected across sampling devices, results were standardized and statistically treated to filter out other sources of variability, resulting in an outcome variable representing the mean difference in measurements that can be attributed to sampling devices. These results were tested for significance using pairwise Tukey contrasts. Differences in organism concentrations were found in 50% of comparisons between sampling skids and the plankton net for ≥ 50 μm, and ≥ 10 μm to < 50 μm size classes, with net samples containing either higher or lower densities. There were no differences for < 10 μm organisms. Future work will be required to explicitly examine the potential effects of flow velocity, sampling duration, sampled volume, and organism concentrations on sampling device performance.

  20. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    International Nuclear Information System (INIS)

    Barnett, J.M.

    2008-01-01

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity of particulate radioactive air samples. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor(reg s ign) 3000) used at PNNL for self absorption effects. There were two methods used in the study, (1) to compare the radioactivity concentration by direct gas-flow proportional counting of the filter to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection and (2) to evaluate sample filters by high resolution visual/infrared microscopy to determine the depth of material loading on or in the filter fiber material. Sixty samples were selected from the archive for acid digestion in the first method and about 30 samples were selected for high resolution visual/infrared microscopy. Mass loading effects were also considered. From the sample filter analysis, large error is associated with the average self absorption factor, however, when the data is compared directly one-to-one, statistically, there appears to be good correlation between the two analytical methods. The mass loading of filters evaluated was <0.2 mg cm-2 and was also compared against other published results. The microscopy analysis shows the sample material remains on the top of the filter paper and does not imbed into the filter media. Results of the microscopy evaluation lead to the conclusion that there is not a mechanism for significant self absorption. The overall conclusion is that self-absorption is not a significant factor in the analysis of filters used at PNNL for radioactive air stack sampling of radionuclide particulates and that an applied correction factor is conservative in determining overall sample activity. A new self absorption factor of 1.0 is recommended

  1. Recent Results from the SAMPLE Experiment

    International Nuclear Information System (INIS)

    Ito, Takeyasu M.

    2004-01-01

    The previous two SAMPLE experiments yielded a measurement of the axial e-N form factor G A e substantially different from the theoretical estimate. In order to confirm this observation, a third SAMPLE experiment was carried out at a lower beam energy of 125 MeV (Q2 = 0.038 (GeV/c)2) on a deuterium target. The data analysis is now at the final stage and the results are consistent with the theoretical prediction of the axial form factor G A e . Also, reevaluation of the background dilution factor and the electromagnetic radiative correction for the 200 MeV deuterium data lead to updated results, which are also consistent with the theoretical prediction

  2. Water quality monitoring: A comparative case study of municipal and Curtin Sarawak's lake samples

    Science.gov (United States)

    Anand Kumar, A.; Jaison, J.; Prabakaran, K.; Nagarajan, R.; Chan, Y. S.

    2016-03-01

    In this study, particle size distribution and zeta potential of the suspended particles in municipal water and lake surface water of Curtin Sarawak's lake were compared and the samples were analysed using dynamic light scattering method. High concentration of suspended particles affects the water quality as well as suppresses the aquatic photosynthetic systems. A new approach has been carried out in the current work to determine the particle size distribution and zeta potential of the suspended particles present in the water samples. The results for the lake samples showed that the particle size ranges from 180nm to 1345nm and the zeta potential values ranges from -8.58 mV to -26.1 mV. High zeta potential value was observed in the surface water samples of Curtin Sarawak's lake compared to the municipal water. The zeta potential values represent that the suspended particles are stable and chances of agglomeration is lower in lake water samples. Moreover, the effects of physico-chemical parameters on zeta potential of the water samples were also discussed.

  3. Statistical literacy and sample survey results

    Science.gov (United States)

    McAlevey, Lynn; Sullivan, Charles

    2010-10-01

    Sample surveys are widely used in the social sciences and business. The news media almost daily quote from them, yet they are widely misused. Using students with prior managerial experience embarking on an MBA course, we show that common sample survey results are misunderstood even by those managers who have previously done a statistics course. In general, they fare no better than managers who have never studied statistics. There are implications for teaching, especially in business schools, as well as for consulting.

  4. A comparative study of sampling techniques for monitoring carcass contamination

    NARCIS (Netherlands)

    Snijders, J.M.A.; Janssen, M.H.W.; Gerats, G.E.; Corstiaensen, G.P.

    1984-01-01

    Four bacteriological sampling techniques i.e. the excision, double swab, agar contract and modified agar contact techniques were compared by sampling pig carcasses before and after chilling. As well as assessing the advantages and disadvantages of the techniques particular attention was paid to

  5. SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-13-189, MCU-13-190, AND MCU-13-191: QUARTERLY SAMPLE FROM SEPTEMBER 2013

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F.; Taylor-Pashow, K.

    2013-10-31

    Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-189, MCU-13-190, and MCU-13-191 received on September 4, 2013 are reported. The results show that the solvent (remaining heel in the SHT tank) at MCU contains excess Isopar L and a deficit concentration of modifier and trioctylamine when compared to the standard MCU solvent. As with the previous solvent sample results, these analyses indicate that the solvent does not require Isopar L trimming at this time. Since MCU is switching to NGS, there is no need to add TOA nor modifier. SRNL also analyzed the SHT sample for {{sup 137}Cs content and determined the measured value is within tolerance and the value has returned to levels observed in 2011.

  6. Preparation of 45 Ca (HDEHP)n and (C8H15O2)2 samples for liquid scintillation counting, compared to 45CaCl2 results

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos Merino, J.M.; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting organic samples of the Di-2-ethylhexyl phosphate calcium complex and the 2-ethyhexanoate calcium salt, labelled with ''45 Ca, is described. The chemical quench, the counting stability and spectral evolution of both compounds is studied in six scintillators, Toluene, Toluene-alcohol, Dioxane-napthalhene, Hisafe II, Ultima-Gold and Instagel, and compared to results obtained from a commercial solution of ''45 CaCl 2

  7. Comparability among four invertebrate sampling methods and two multimetric indexes, Fountain Creek Basin, Colorado, 2010–2012

    Science.gov (United States)

    Bruce, James F.; Roberts, James J.; Zuellig, Robert E.

    2018-05-24

    The U.S. Geological Survey (USGS), in cooperation with Colorado Springs City Engineering and Colorado Springs Utilities, analyzed previously collected invertebrate data to determine the comparability among four sampling methods and two versions (2010 and 2017) of the Colorado Benthic Macroinvertebrate Multimetric Index (MMI). For this study, annual macroinvertebrate samples were collected concurrently (in space and time) at 15 USGS surface-water gaging stations in the Fountain Creek Basin from 2010 to 2012 using four sampling methods. The USGS monitoring project in the basin uses two of the methods and the Colorado Department of Public Health and Environment recommends the other two. These methods belong to two distinct sample types, one that targets single habitats and one that targets multiple habitats. The study results indicate that there are significant differences in MMI values obtained from the single-habitat and multihabitat sample types but methods from each program within each sample type produced comparable values. This study also determined that MMI values calculated by different versions of the Colorado Benthic Macroinvertebrate MMI are indistinguishable. This indicates that the Colorado Department of Public Health and Environment methods are comparable with the USGS monitoring project methods for single-habitat and multihabitat sample types. This report discusses the direct application of the study results to inform the revision of the existing USGS monitoring project in the Fountain Creek Basin.

  8. Tank 241-SY-102, January 2000 Compatibility Grab Samples Analytical Results for the Final Report

    International Nuclear Information System (INIS)

    BELL, K.E.

    2000-01-01

    This document is the format IV, final report for the tank 241-SY-102 (SY-102) grab samples taken in January 2000 to address waste compatibility concerns. Chemical, radiochemical, and physical analyses on the tank SY-102 samples were performed as directed in Comparability Grab Sampling and Analysis Plan for Fiscal Year 2000 (Sasaki 1999). No notification limits were exceeded. Preliminary data on samples 2SY-99-5, -6, and -7 were reported in ''Format II Report on Tank 241-SY-102 Waste Compatibility Grab Samples Taken in January 2000'' (Lockrem 2000). The data presented here represent the final results

  9. Assessing representativeness of sampling methods for reaching men who have sex with men: a direct comparison of results obtained from convenience and probability samples.

    Science.gov (United States)

    Schwarcz, Sandra; Spindler, Hilary; Scheer, Susan; Valleroy, Linda; Lansky, Amy

    2007-07-01

    Convenience samples are used to determine HIV-related behaviors among men who have sex with men (MSM) without measuring the extent to which the results are representative of the broader MSM population. We compared results from a cross-sectional survey of MSM recruited from gay bars between June and October 2001 to a random digit dial telephone survey conducted between June 2002 and January 2003. The men in the probability sample were older, better educated, and had higher incomes than men in the convenience sample, the convenience sample enrolled more employed men and men of color. Substance use around the time of sex was higher in the convenience sample but other sexual behaviors were similar. HIV testing was common among men in both samples. Periodic validation, through comparison of data collected by different sampling methods, may be useful when relying on survey data for program and policy development.

  10. Sampling Key Populations for HIV Surveillance: Results From Eight Cross-Sectional Studies Using Respondent-Driven Sampling and Venue-Based Snowball Sampling.

    Science.gov (United States)

    Rao, Amrita; Stahlman, Shauna; Hargreaves, James; Weir, Sharon; Edwards, Jessie; Rice, Brian; Kochelani, Duncan; Mavimbela, Mpumelelo; Baral, Stefan

    2017-10-20

    In using regularly collected or existing surveillance data to characterize engagement in human immunodeficiency virus (HIV) services among marginalized populations, differences in sampling methods may produce different pictures of the target population and may therefore result in different priorities for response. The objective of this study was to use existing data to evaluate the sample distribution of eight studies of female sex workers (FSW) and men who have sex with men (MSM), who were recruited using different sampling approaches in two locations within Sub-Saharan Africa: Manzini, Swaziland and Yaoundé, Cameroon. MSM and FSW participants were recruited using either respondent-driven sampling (RDS) or venue-based snowball sampling. Recruitment took place between 2011 and 2016. Participants at each study site were administered a face-to-face survey to assess sociodemographics, along with the prevalence of self-reported HIV status, frequency of HIV testing, stigma, and other HIV-related characteristics. Crude and RDS-adjusted prevalence estimates were calculated. Crude prevalence estimates from the venue-based snowball samples were compared with the overlap of the RDS-adjusted prevalence estimates, between both FSW and MSM in Cameroon and Swaziland. RDS samples tended to be younger (MSM aged 18-21 years in Swaziland: 47.6% [139/310] in RDS vs 24.3% [42/173] in Snowball, in Cameroon: 47.9% [99/306] in RDS vs 20.1% [52/259] in Snowball; FSW aged 18-21 years in Swaziland 42.5% [82/325] in RDS vs 8.0% [20/249] in Snowball; in Cameroon 15.6% [75/576] in RDS vs 8.1% [25/306] in Snowball). They were less educated (MSM: primary school completed or less in Swaziland 42.6% [109/310] in RDS vs 4.0% [7/173] in Snowball, in Cameroon 46.2% [138/306] in RDS vs 14.3% [37/259] in Snowball; FSW: primary school completed or less in Swaziland 86.6% [281/325] in RDS vs 23.9% [59/247] in Snowball, in Cameroon 87.4% [520/576] in RDS vs 77.5% [238/307] in Snowball) than the snowball

  11. Comparing interval estimates for small sample ordinal CFA models.

    Science.gov (United States)

    Natesan, Prathiba

    2015-01-01

    Robust maximum likelihood (RML) and asymptotically generalized least squares (AGLS) methods have been recommended for fitting ordinal structural equation models. Studies show that some of these methods underestimate standard errors. However, these studies have not investigated the coverage and bias of interval estimates. An estimate with a reasonable standard error could still be severely biased. This can only be known by systematically investigating the interval estimates. The present study compares Bayesian, RML, and AGLS interval estimates of factor correlations in ordinal confirmatory factor analysis models (CFA) for small sample data. Six sample sizes, 3 factor correlations, and 2 factor score distributions (multivariate normal and multivariate mildly skewed) were studied. Two Bayesian prior specifications, informative and relatively less informative were studied. Undercoverage of confidence intervals and underestimation of standard errors was common in non-Bayesian methods. Underestimated standard errors may lead to inflated Type-I error rates. Non-Bayesian intervals were more positive biased than negatively biased, that is, most intervals that did not contain the true value were greater than the true value. Some non-Bayesian methods had non-converging and inadmissible solutions for small samples and non-normal data. Bayesian empirical standard error estimates for informative and relatively less informative priors were closer to the average standard errors of the estimates. The coverage of Bayesian credibility intervals was closer to what was expected with overcoverage in a few cases. Although some Bayesian credibility intervals were wider, they reflected the nature of statistical uncertainty that comes with the data (e.g., small sample). Bayesian point estimates were also more accurate than non-Bayesian estimates. The results illustrate the importance of analyzing coverage and bias of interval estimates, and how ignoring interval estimates can be misleading

  12. Self-sampling with HPV mRNA analyses from vagina and urine compared with cervical samples.

    Science.gov (United States)

    Asciutto, Katrin Christine; Ernstson, Avalon; Forslund, Ola; Borgfeldt, Christer

    2018-04-01

    In order to increase coverage in the organized cervical screening program, self-sampling with HPV analyses has been suggested. The aim was to compare human papillomavirus (HPV) mRNA detection in vaginal and urine self-collected samples with clinician-taken cervical samples and the corresponding clinician-taken histological specimens. Self-collected vaginal, urine and clinician-taken cervical samples were analyzed from 209 women with the Aptima mRNA assay (Hologic Inc, MA, USA). Cervical cytology, colposcopy, biopsy and/or the loop electrosurgical excision procedure (LEEP) were performed in every examination. The sensitivity of the HPV mRNA test in detecting high-grade squamous intraepithelial lesions (HSIL)/adenocarcinoma in situ (AIS)/cancer cases was as follows: for the vaginal self-samples 85.5% (95% CI; 75.0-92.8), the urinary samples 44.8% (95% CI; 32.6-57.4), and for routine cytology 81.7% (95% CI; 70.7-89.9). For the clinician-taken cervical HPV samples the sensitivity of the HPV mRNA test in detecting HSIL/AIS/cancer was 100.0% (95% CI; 94.9-100.0). The specificity of the HPV mRNA was similar for the clinician-taken cervical HPV samples and the self-samples: 49.0% vs. 48.1%. The urinary HPV samples had a specificity of 61.9% and cytology had a specificity of 93.3%. The sensitivity of the Aptima HPV mRNA test in detecting HSIL/AIS/cancer from vaginal self-samples was similar to that of routine cytology. The Aptima HPV mRNA vaginal self-sampling analysis may serve as a complement in screening programs. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Comparing Microbiome Sampling Methods in a Wild Mammal: Fecal and Intestinal Samples Record Different Signals of Host Ecology, Evolution.

    Science.gov (United States)

    Ingala, Melissa R; Simmons, Nancy B; Wultsch, Claudia; Krampis, Konstantinos; Speer, Kelly A; Perkins, Susan L

    2018-01-01

    The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces) and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated.

  14. Comparing Microbiome Sampling Methods in a Wild Mammal: Fecal and Intestinal Samples Record Different Signals of Host Ecology, Evolution

    Directory of Open Access Journals (Sweden)

    Melissa R. Ingala

    2018-05-01

    Full Text Available The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated.

  15. Two methods of self-sampling compared to clinician sampling to detect reproductive tract infections in Gugulethu, South Africa

    NARCIS (Netherlands)

    van de Wijgert, Janneke; Altini, Lydia; Jones, Heidi; de Kock, Alana; Young, Taryn; Williamson, Anna-Lise; Hoosen, Anwar; Coetzee, Nicol

    2006-01-01

    To assess the validity, feasibility, and acceptability of 2 methods of self-sampling compared to clinician sampling during a speculum examination. To improve screening for reproductive tract infections (RTIs) in resource-poor settings. In a public clinic in Cape Town, 450 women underwent a speculum

  16. Measuring larval nematode contamination on cattle pastures: Comparing two herbage sampling methods.

    Science.gov (United States)

    Verschave, S H; Levecke, B; Duchateau, L; Vercruysse, J; Charlier, J

    2015-06-15

    Assessing levels of pasture larval contamination is frequently used to study the population dynamics of the free-living stages of parasitic nematodes of livestock. Direct quantification of infective larvae (L3) on herbage is the most applied method to measure pasture larval contamination. However, herbage collection remains labour intensive and there is a lack of studies addressing the variation induced by the sampling method and the required sample size. The aim of this study was (1) to compare two different sampling methods in terms of pasture larval count results and time required to sample, (2) to assess the amount of variation in larval counts at the level of sample plot, pasture and season, respectively and (3) to calculate the required sample size to assess pasture larval contamination with a predefined precision using random plots across pasture. Eight young stock pastures of different commercial dairy herds were sampled in three consecutive seasons during the grazing season (spring, summer and autumn). On each pasture, herbage samples were collected through both a double-crossed W-transect with samples taken every 10 steps (method 1) and four random located plots of 0.16 m(2) with collection of all herbage within the plot (method 2). The average (± standard deviation (SD)) pasture larval contamination using sampling methods 1 and 2 was 325 (± 479) and 305 (± 444)L3/kg dry herbage (DH), respectively. Large discrepancies in pasture larval counts of the same pasture and season were often seen between methods, but no significant difference (P = 0.38) in larval counts between methods was found. Less time was required to collect samples with method 2. This difference in collection time between methods was most pronounced for pastures with a surface area larger than 1 ha. The variation in pasture larval counts from samples generated by random plot sampling was mainly due to the repeated measurements on the same pasture in the same season (residual variance

  17. Evaluation of immunization coverage by lot quality assurance sampling compared with 30-cluster sampling in a primary health centre in India.

    Science.gov (United States)

    Singh, J; Jain, D C; Sharma, R S; Verghese, T

    1996-01-01

    The immunization coverage of infants, children and women residing in a primary health centre (PHC) area in Rajasthan was evaluated both by lot quality assurance sampling (LQAS) and by the 30-cluster sampling method recommended by WHO's Expanded Programme on Immunization (EPI). The LQAS survey was used to classify 27 mutually exclusive subunits of the population, defined as residents in health subcentre areas, on the basis of acceptable or unacceptable levels of immunization coverage among infants and their mothers. The LQAS results from the 27 subcentres were also combined to obtain an overall estimate of coverage for the entire population of the primary health centre, and these results were compared with the EPI cluster survey results. The LQAS survey did not identify any subcentre with a level of immunization among infants high enough to be classified as acceptable; only three subcentres were classified as having acceptable levels of tetanus toxoid (TT) coverage among women. The estimated overall coverage in the PHC population from the combined LQAS results showed that a quarter of the infants were immunized appropriately for their ages and that 46% of their mothers had been adequately immunized with TT. Although the age groups and the periods of time during which the children were immunized differed for the LQAS and EPI survey populations, the characteristics of the mothers were largely similar. About 57% (95% CI, 46-67) of them were found to be fully immunized with TT by 30-cluster sampling, compared with 46% (95% CI, 41-51) by stratified random sampling. The difference was not statistically significant. The field work to collect LQAS data took about three times longer, and cost 60% more than the EPI survey. The apparently homogeneous and low level of immunization coverage in the 27 subcentres makes this an impractical situation in which to apply LQAS, and the results obtained were therefore not particularly useful. However, if LQAS had been applied by local

  18. Water quality monitoring: A comparative case study of municipal and Curtin Sarawak's lake samples

    International Nuclear Information System (INIS)

    Kumar, A Anand; Prabakaran, K; Nagarajan, R; Jaison, J; Chan, Y S

    2016-01-01

    In this study, particle size distribution and zeta potential of the suspended particles in municipal water and lake surface water of Curtin Sarawak's lake were compared and the samples were analysed using dynamic light scattering method. High concentration of suspended particles affects the water quality as well as suppresses the aquatic photosynthetic systems. A new approach has been carried out in the current work to determine the particle size distribution and zeta potential of the suspended particles present in the water samples. The results for the lake samples showed that the particle size ranges from 180nm to 1345nm and the zeta potential values ranges from -8.58 mV to -26.1 mV. High zeta potential value was observed in the surface water samples of Curtin Sarawak's lake compared to the municipal water. The zeta potential values represent that the suspended particles are stable and chances of agglomeration is lower in lake water samples. Moreover, the effects of physico-chemical parameters on zeta potential of the water samples were also discussed. (paper)

  19. Characterization Results for the January 2017 H-Tank Farm 2H Evaporator Overhead Sample

    Energy Technology Data Exchange (ETDEWEB)

    Truong, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nicholson, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-04-11

    This report contains the radioanalytical results of the 2H evaporator overhead sample received at SRNL on January 19, 2017. Specifically, concentrations of 137Cs, 90Sr, and 129I are reported and compared to the corresponding Waste Acceptance Criteria (WAC) limits of the Effluent Treatment Project (ETP) Waste Water Collection Tank (WWCT) (rev. 6). All of the radionuclide concentrations in the sample were found to be in compliance with the ETP WAC limits.

  20. APTIMA assay on SurePath liquid-based cervical samples compared to endocervical swab samples facilitated by a real time database

    Directory of Open Access Journals (Sweden)

    Khader Samer

    2010-01-01

    Full Text Available Background: Liquid-based cytology (LBC cervical samples are increasingly being used to test for pathogens, including: HPV, Chlamydia trachomatis (CT and Neisseria gonorrhoeae (GC using nucleic acid amplification tests. Several reports have shown the accuracy of such testing on ThinPrep (TP LBC samples. Fewer studies have evaluated SurePath (SP LBC samples, which utilize a different specimen preservative. This study was undertaken to assess the performance of the Aptima Combo 2 Assay (AC2 for CT and GC on SP versus endocervical swab samples in our laboratory. Materials and Methods: The live pathology database of Montefiore Medical Center was searched for patients with AC2 endocervical swab specimens and SP Paps taken the same day. SP samples from CT- and/or GC-positive endocervical swab patients and randomly selected negative patients were studied. In each case, 1.5 ml of the residual SP vial sample, which was in SP preservative and stored at room temperature, was transferred within seven days of collection to APTIMA specimen transfer tubes without any sample or patient identifiers. Blind testing with the AC2 assay was performed on the Tigris DTS System (Gen-probe, San Diego, CA. Finalized SP results were compared with the previously reported endocervical swab results for the entire group and separately for patients 25 years and younger and patients over 25 years. Results: SP specimens from 300 patients were tested. This included 181 swab CT-positive, 12 swab GC-positive, 7 CT and GC positive and 100 randomly selected swab CT and GC negative patients. Using the endocervical swab results as the patient′s infection status, AC2 assay of the SP samples showed: CT sensitivity 89.3%, CT specificity 100.0%; GC sensitivity and specificity 100.0%. CT sensitivity for patients 25 years or younger was 93.1%, versus 80.7% for patients over 25 years, a statistically significant difference (P = 0.02. Conclusions: Our results show that AC2 assay of 1.5 ml SP

  1. SAMPLE RESULTS FROM THE INTEGRATED SALT DISPOSITION PROGRAM MACROBATCH 4 TANK 21H QUALIFICATION SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T.; Fink, S.

    2011-06-22

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H to qualify them for use in the Integrated Salt Disposition Program (ISDP) Batch 4 processing. All sample results agree with expectations based on prior analyses where available. No issues with the projected Salt Batch 4 strategy are identified. This revision includes additional data points that were not available in the original issue of the document, such as additional plutonium results, the results of the monosodium titanate (MST) sorption test and the extraction, scrub strip (ESS) test. This report covers the revision to the Tank 21H qualification sample results for Macrobatch (Salt Batch) 4 of the Integrated Salt Disposition Program (ISDP). A previous document covers initial characterization which includes results for a number of non-radiological analytes. These results were used to perform aluminum solubility modeling to determine the hydroxide needs for Salt Batch 4 to prevent the precipitation of solids. Sodium hydroxide was then added to Tank 21 and additional samples were pulled for the analyses discussed in this report. This work was specified by Task Technical Request and by Task Technical and Quality Assurance Plan (TTQAP).

  2. Comparative multielement analyses of airborne particulate samples collected in various areas

    International Nuclear Information System (INIS)

    Mamuro, Tetsuo; Matsuda, Yatsuka; Mizohata, Akira

    1973-01-01

    In order to grasp the characteristic features of the air pollution by particulates in various areas in Japan, multielement analyses by instrumental neutron activation analysis and radioisotope energy dispersive X-ray fluorescence analysis were applied to 31 airborne particulate samples collected in 15 different areas, and the analytical results obtained were compared with one another. All the samples were collected by so-called ''10 micron cut'' samplers, the collection efficiency of which is considered to be 50% at 8μ and nearly zero beyond 10μ. Among the areas in question there are clean seaside areas, heavily industrialized areas, small cities along the Inland Sea or the Pacific Ocean around which industrialization is progressing, a small city having only a big iron work, an area famous for its ceramic industry and so on. The atmospheres over them were found to be quite different not only in pollution extent but also in pollution pattern. (auth.)

  3. Most Recent Sampling Results for Annex III Building

    Science.gov (United States)

    Contains email from Scott Miller, US EPA to Scott Kramer. Subject: Most Recent Sampling Results for Annex III Building. (2:52 PM) and Gore(TM) Surveys Analytical Results U.S. Geological Survey, Montgomery, AL.

  4. Results For The Third Quarter Calendar Year 2016 Tank 50H Salt Solution Sample

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-10-13

    In this memorandum, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2016 (CY16) sample of Tank 50H salt solution are presented in tabulated form. The Third Quarter CY16 Tank 50H samples (a 200 mL sample obtained 6” below the surface (HTF-5-16-63) and a 1 L sample obtained 66” from the tank bottom (HTF-50-16-64)) were obtained on July 14, 2016 and received at Savannah River National Laboratory (SRNL) on the same day. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours, and the samples were pulled immediately after pump shut down. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Third Quarter CY16 sampling of Tank 50H were requested by Savannah River Remediation (SRR) personnel and details of the testing are presented in the SRNL TTQAP.

  5. Parameter sampling capabilities of sequential and simultaneous data assimilation: II. Statistical analysis of numerical results

    International Nuclear Information System (INIS)

    Fossum, Kristian; Mannseth, Trond

    2014-01-01

    We assess and compare parameter sampling capabilities of one sequential and one simultaneous Bayesian, ensemble-based, joint state-parameter (JS) estimation method. In the companion paper, part I (Fossum and Mannseth 2014 Inverse Problems 30 114002), analytical investigations lead us to propose three claims, essentially stating that the sequential method can be expected to outperform the simultaneous method for weakly nonlinear forward models. Here, we assess the reliability and robustness of these claims through statistical analysis of results from a range of numerical experiments. Samples generated by the two approximate JS methods are compared to samples from the posterior distribution generated by a Markov chain Monte Carlo method, using four approximate measures of distance between probability distributions. Forward-model nonlinearity is assessed from a stochastic nonlinearity measure allowing for sufficiently large model dimensions. Both toy models (with low computational complexity, and where the nonlinearity is fairly easy to control) and two-phase porous-media flow models (corresponding to down-scaled versions of problems to which the JS methods have been frequently applied recently) are considered in the numerical experiments. Results from the statistical analysis show strong support of all three claims stated in part I. (paper)

  6. Specific spheres of application of ionising radiation effects, some realized results and comparative advantages

    International Nuclear Information System (INIS)

    Benderac, R.

    2007-01-01

    The papers discusses some results of ionizing radiation effects in realization of non-destructive methods, achieved progress from the aspect of innovation, comparative results with previously used methods, etc. A review is given of methods based on alpha-radiography, auto-alpha radiography, beta-radiography, X-ray-fluorescent analysis, X- and gamma radiography, and photos of specific samples of neutron radiography [sr

  7. Results for the first quarter calendar year 2017 tank 50H salt solution sample

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-04-12

    In this memorandum, the chemical and radionuclide contaminant results from the First Quarter Calendar Year 2017 (CY17) sample of Tank 50H salt solution are presented in tabulated form. The First Quarter CY17 Tank 50H samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-7) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-8)] were obtained on January 15, 2017 and received at Savannah River National Laboratory (SRNL) on January 16, 2017. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours and the samples were pulled immediately after pump shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. The chemical and radionuclide contaminant results from the characterization of the First Quarter CY17 sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan (TTQAP). This memorandum is part of Deliverable 2 from SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50H saltstone task.

  8. Analytical results of Tank 38H core samples -- Fall 1999

    International Nuclear Information System (INIS)

    Swingle, R.F.

    2000-01-01

    Two samples were pulled from Tank 38H in the Fall of 1999: a variable depth sample (VDS) of the supernate was pulled in October and a core sample from the salt layer was pulled in December. Analysis of the rinse from the outside of the core sample indicated no sign of volatile or semivolatile organics. Both supernate and solids from the VDS and the dried core sample solids were analyzed for isotopes which could pose a criticality concern and also for elements which could serve as neutron poisons, as well as other elements. Results of the elemental analyses of these samples show significant elements present to mitigate the potential for nuclear criticality. However, it should be noted the results given for the VDS solids elemental analyses may be higher than the actual concentration in the solids, since the filter paper was dissolved along with the sample solids

  9. Comparing Respondent-Driven Sampling and Targeted Sampling Methods of Recruiting Injection Drug Users in San Francisco

    Science.gov (United States)

    Malekinejad, Mohsen; Vaudrey, Jason; Martinez, Alexis N.; Lorvick, Jennifer; McFarland, Willi; Raymond, H. Fisher

    2010-01-01

    The objective of this article is to compare demographic characteristics, risk behaviors, and service utilization among injection drug users (IDUs) recruited from two separate studies in San Francisco in 2005, one which used targeted sampling (TS) and the other which used respondent-driven sampling (RDS). IDUs were recruited using TS (n = 651) and RDS (n = 534) and participated in quantitative interviews that included demographic characteristics, risk behaviors, and service utilization. Prevalence estimates and 95% confidence intervals (CIs) were calculated to assess whether there were differences in these variables by sampling method. There was overlap in 95% CIs for all demographic variables except African American race (TS: 45%, 53%; RDS: 29%, 44%). Maps showed that the proportion of IDUs distributed across zip codes were similar for the TS and RDS sample, with the exception of a single zip code that was more represented in the TS sample. This zip code includes an isolated, predominantly African American neighborhood where only the TS study had a field site. Risk behavior estimates were similar for both TS and RDS samples, although self-reported hepatitis C infection was lower in the RDS sample. In terms of service utilization, more IDUs in the RDS sample reported no recent use of drug treatment and syringe exchange program services. Our study suggests that perhaps a hybrid sampling plan is best suited for recruiting IDUs in San Francisco, whereby the more intensive ethnographic and secondary analysis components of TS would aid in the planning of seed placement and field locations for RDS. PMID:20582573

  10. Administration of antibiotic agents before intraoperative sampling in orthopedic infections alters culture results.

    Science.gov (United States)

    Al-Mayahi, Mohamed; Cian, Anais; Lipsky, Benjamin A; Suvà, Domizio; Müller, Camillo; Landelle, Caroline; Miozzari, Hermès H; Uçkay, Ilker

    2015-11-01

    Many physicians and surgeons think that prescribing antibiotics before intraoperative sampling does not alter the microbiological results. Case-control study of adult patients hospitalized with orthopedic infections. Among 2740 episodes of orthopedic infections, 1167 (43%) had received antibiotic therapy before surgical sampling. Among these, 220 (19%) grew no pathogens while the proportion of culture-negative results in the 2573 who had no preoperative antibiotic therapy was only 6%. By multivariate analyses, pre-operative antibiotic exposure was associated with significantly more culture-negative results (odds ratio 2.8, 95% confidence interval 2.1-3.7), more non-fermenting rods and skin commensals (odds ratio 2.8 and 3.0, respectively). Even a single pre-operative dose of antibiotic was significantly associated with subsequent culture-negative results (19/93 vs. 297/2350; χ²-test, p = 0.01) and skin commensals (17/74 vs. 274/2350; p = 0.01) compared to episodes without preceding prophylaxis. Prior antibiotic use, including single-dose prophylactic administrations, is three-fold associated with culture-negative results, non-fermenting rods and resistant skin commensals. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  11. Comparing hair-morphology and molecular methods to identify fecal samples from Neotropical felids.

    Directory of Open Access Journals (Sweden)

    Carlos C Alberts

    Full Text Available To avoid certain problems encountered with more-traditional and invasive methods in behavioral-ecology studies of mammalian predators, such as felids, molecular approaches have been employed to identify feces found in the field. However, this method requires a complete molecular biology laboratory, and usually also requires very fresh fecal samples to avoid DNA degradation. Both conditions are normally absent in the field. To address these difficulties, identification based on morphological characters (length, color, banding, scales and medullar patterns of hairs found in feces could be employed as an alternative. In this study we constructed a morphological identification key for guard hairs of eight Neotropical felids (jaguar, oncilla, Geoffroy's cat, margay, ocelot, Pampas cat, puma and jaguarundi and compared its efficiency to that of a molecular identification method, using the ATP6 region as a marker. For this molecular approach, we simulated some field conditions by postponing sample-conservation procedures. A blind test of the identification key obtained a nearly 70% overall success rate, which we considered equivalent to or better than the results of some molecular methods (probably due to DNA degradation found in other studies. The jaguar, puma and jaguarundi could be unequivocally discriminated from any other Neotropical felid. On a scale ranging from inadequate to excellent, the key proved poor only for the margay, with only 30% of its hairs successfully identified using this key; and have intermediate success rates for the remaining species, the oncilla, Geoffroy's cat, ocelot and Pampas cat, were intermediate. Complementary information about the known distributions of felid populations may be necessary to substantially improve the results obtained with the key. Our own molecular results were even better, since all blind-tested samples were correctly identified. Part of these identifications were made from samples kept in suboptimal

  12. Results of Plutonium Intercalibration in Seawater and Seaweed Samples

    International Nuclear Information System (INIS)

    Fukai, R.; Murray, C.N.

    1976-01-01

    The results of the intercalibration exercise for the measurement of plutonium-239 and 228 in two seawater samples SW-I-1 and SW-I-2 and a marine algae sample AG-I-1 are presented. Seventeen laboratories from 8 countries as well as the IAEA International Laboratory of Marine Radioactivity took part. A discussion of the results and methods used in the analysis is given. It is concluded that in spite of the complicated chemical procedures involved in plutonium analysis, the scatter of the reported results was much smaller than that for fission product radionuclides such as strontium-90, ruthenium-106, cesium-137 etc. (author)

  13. Single blood-Hg samples can result in exposure misclassification: temporal monitoring within the Japanese community (United States

    Directory of Open Access Journals (Sweden)

    Tsuchiya Ami

    2012-06-01

    Full Text Available Abstract Background The most prominent non-occupational source of exposure to methylmercury is the consumption of fish. In this study we examine a fish consuming population to determine the extent of temporal exposure and investigate the extent to which single time estimates of methylmercury exposure based on blood-Hg concentration can provide reliable estimates of longer-term average exposure. Methods Blood-mercury levels were obtained from a portion of the Arsenic Mercury Intake Biometric Study (AMIBS cohort. Specifically, 56 Japanese women residing in the Puget Sound area of Washington State, US were sampled on three occasions across a one-year period. Results An average of 135 days separated samples, with mean blood-mercury levels for the visits being 5.1, 6.6 and 5.0 μg/l and geometric means being 2.7, 4.5 and 3.1 μg/l. The blood-mercury levels in this group exceed national averages with geometric means for two of the visits being between the 90th and 95th percentiles of nationally observed levels and the lowest geometric mean being between the 75th and 90th percentile. Group means were not significantly different across sampling periods suggesting that exposure of combined subjects remained relatively constant. Comparing intra-individual results over time did not reveal a strong correlation among visits (r = 0.19, 0.50, 0.63 between 1st and 2nd, 2nd and 3rd, and 1st and 3rd sample results, respectively. In comparing blood-mercury levels across two sampling interval combinations (1st and 2nd, 2nd and 3rd, and 1st and 3rd visits, respectively, 58% (n = 34, 53% (n = 31 and 29% (n = 17 of the individuals had at least a 100% difference in blood-Hg levels. Conclusions Point estimates of blood-mercury, when compared with three sample averages, may not reflect temporal variability and individual exposures estimated on the basis of single blood samples should be treated with caution as indicators of long-term exposure

  14. Air sampling methods to evaluate microbial contamination in operating theatres: results of a comparative study in an orthopaedics department.

    Science.gov (United States)

    Napoli, C; Tafuri, S; Montenegro, L; Cassano, M; Notarnicola, A; Lattarulo, S; Montagna, M T; Moretti, B

    2012-02-01

    To evaluate the level of microbial contamination of air in operating theatres using active [i.e. surface air system (SAS)] and passive [i.e. index of microbial air contamination (IMA) and nitrocellulose membranes positioned near the wound] sampling systems. Sampling was performed between January 2010 and January 2011 in the operating theatre of the orthopaedics department in a university hospital in Southern Italy. During surgery, the mean bacterial loads recorded were 2232.9 colony-forming units (cfu)/m(2)/h with the IMA method, 123.2 cfu/m(3) with the SAS method and 2768.2 cfu/m(2)/h with the nitrocellulose membranes. Correlation was found between the results of the three methods. Staphylococcus aureus was detected in 12 of 60 operations (20%) with the membranes, five (8.3%) operations with the SAS method, and three operations (5%) with the IMA method. Use of nitrocellulose membranes placed near a wound is a valid method for measuring the microbial contamination of air. This method was more sensitive than the IMA method and was not subject to any calibration bias, unlike active air monitoring systems. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. The interrelation between premenstrual syndrome and major depression: Results from a population-based sample

    Directory of Open Access Journals (Sweden)

    Weiss Carine

    2011-10-01

    Full Text Available Abstract Background Research about the relationship between premenstrual syndrome (PMS and major depression is limited. This study examined the relationship between moderate to severe PMS and major depression in a population-based sample of women of reproductive age. The objectives of the study were to assess the association between premenstrual syndrome and major depression, to analyse how PMS and major depression differ and to characterise the group of women who report both PMS and major depression. Methods Data were obtained from the Swiss Health Survey 2007. Included in the analysis was data from women under the age of 55 without hysterectomy and who answered the questions on PMS symptoms. The population-based sample consisted of 3518 women. Weighted prevalence rates were calculated and relative risk ratios for PMS, major depression and women who reported both PMS and major depression, were calculated with logistic multinominal logit regression. Results The prevalence of major depression was 11.3% in women screening positive for moderate PMS and 24.6% in women screening positive for severe PMS. Compared to women without any of these conditions, women who reported moderate to severe alcohol consumption had a lower risk for PMS. Women reporting use of antidepressants, and use of oral contraceptives had a higher risk for major depression compared to women without any of these conditions. Women reporting work dissatisfaction had a higher risk for PMS. A higher relative risk to report both PMS and major depression compared to women without PMS or major depression was related to factors such as high psychological distress, low mastery, psychotropic drug consumption, and low self-rated health. Conclusions The results suggested that women who suffer from both PMS and major depression are more impaired compared to women with only one disorder. The results further indicated that PMS and major depression are different disorders that can, however, co-occur.

  16. Characterization of a low-level radioactive waste grout: Sampling and test results

    International Nuclear Information System (INIS)

    Martin, P.F.C.; Lokken, R.O.

    1992-12-01

    WHC manages and operates the grout treatment facility at Hanford as part of a DOE program to clean up wastes stored at federal nuclear production sites. PNL provides support to the grout disposal program through pilot-scale tests, performance assessments, and formulation verification activities. in 1988 and 1989, over one million gallons of a low-level radioactive liquid waste was processed through the facility to produce a grout waste that was then deposited in an underground vault. The liquid waste was phosphate/sulfate waste (PSW) generated in decontamination of the N Reactor. PNL sampled and tested the grout produced during the second half of the PSW campaign to support quality verification activities prior to grout vault closure. Samples of grout were obtained by inserting nested-tube samplers into the grout slurry in the vault. After the grout had cured, the inner tube of the sampler was removed and the grout samples extracted. Tests for compressive strength, sonic velocity, and leach testing were used to assess grout quality; results were compared to those from pilot-scale test grouts made with a simulated PSW. The grout produced during the second half of the PSW campaign exceeded compressive strength and leachability formulation criteria. The nested tube samplers were effective in collecting samples of grout although their use introduced greater variability into the compressive strength data

  17. Results for the Fourth Quarter Calendar Year 2015 Tank 50H Salt Solution Sample

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-01-11

    In this memorandum, the chemical and radionuclide contaminant results from the Fourth Quarter Calendar Year 2015 (CY15) sample of Tank 50H salt solution are presented in tabulated form. The Fourth Quarter CY15 Tank 50H samples were obtained on October 29, 2015 and received at Savannah River National Laboratory (SRNL) on October 30, 2015. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Salt Feed Tank in the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Fourth Quarter Calendar Year 2015 (CY15) sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan.

  18. Comparative analysis of whole mount processing and systematic sampling of radical prostatectomy specimens: pathological outcomes and risk of biochemical recurrence.

    Science.gov (United States)

    Salem, Shady; Chang, Sam S; Clark, Peter E; Davis, Rodney; Herrell, S Duke; Kordan, Yakup; Wills, Marcia L; Shappell, Scott B; Baumgartner, Roxelyn; Phillips, Sharon; Smith, Joseph A; Cookson, Michael S; Barocas, Daniel A

    2010-10-01

    Whole mount processing is more resource intensive than routine systematic sampling of radical retropubic prostatectomy specimens. We compared whole mount and systematic sampling for detecting pathological outcomes, and compared the prognostic value of pathological findings across pathological methods. We included men (608 whole mount and 525 systematic sampling samples) with no prior treatment who underwent radical retropubic prostatectomy at Vanderbilt University Medical Center between January 2000 and June 2008. We used univariate and multivariate analysis to compare the pathological outcome detection rate between pathological methods. Kaplan-Meier curves and the log rank test were used to compare the prognostic value of pathological findings across pathological methods. There were no significant differences between the whole mount and the systematic sampling groups in detecting extraprostatic extension (25% vs 30%), positive surgical margins (31% vs 31%), pathological Gleason score less than 7 (49% vs 43%), 7 (39% vs 43%) or greater than 7 (12% vs 13%), seminal vesicle invasion (8% vs 10%) or lymph node involvement (3% vs 5%). Tumor volume was higher in the systematic sampling group and whole mount detected more multiple surgical margins (each p systematic sampling yield similar pathological information. Each method stratifies patients into comparable risk groups for biochemical recurrence. Thus, while whole mount is more resource intensive, it does not appear to result in improved detection of clinically important pathological outcomes or prognostication. Copyright © 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. A comparative proteomics method for multiple samples based on a 18O-reference strategy and a quantitation and identification-decoupled strategy.

    Science.gov (United States)

    Wang, Hongbin; Zhang, Yongqian; Gui, Shuqi; Zhang, Yong; Lu, Fuping; Deng, Yulin

    2017-08-15

    Comparisons across large numbers of samples are frequently necessary in quantitative proteomics. Many quantitative methods used in proteomics are based on stable isotope labeling, but most of these are only useful for comparing two samples. For up to eight samples, the iTRAQ labeling technique can be used. For greater numbers of samples, the label-free method has been used, but this method was criticized for low reproducibility and accuracy. An ingenious strategy has been introduced, comparing each sample against a 18 O-labeled reference sample that was created by pooling equal amounts of all samples. However, it is necessary to use proportion-known protein mixtures to investigate and evaluate this new strategy. Another problem for comparative proteomics of multiple samples is the poor coincidence and reproducibility in protein identification results across samples. In present study, a method combining 18 O-reference strategy and a quantitation and identification-decoupled strategy was investigated with proportion-known protein mixtures. The results obviously demonstrated that the 18 O-reference strategy had greater accuracy and reliability than other previously used comparison methods based on transferring comparison or label-free strategies. By the decoupling strategy, the quantification data acquired by LC-MS and the identification data acquired by LC-MS/MS are matched and correlated to identify differential expressed proteins, according to retention time and accurate mass. This strategy made protein identification possible for all samples using a single pooled sample, and therefore gave a good reproducibility in protein identification across multiple samples, and allowed for optimizing peptide identification separately so as to identify more proteins. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Reliability of environmental sampling culture results using the negative binomial intraclass correlation coefficient.

    Science.gov (United States)

    Aly, Sharif S; Zhao, Jianyang; Li, Ben; Jiang, Jiming

    2014-01-01

    The Intraclass Correlation Coefficient (ICC) is commonly used to estimate the similarity between quantitative measures obtained from different sources. Overdispersed data is traditionally transformed so that linear mixed model (LMM) based ICC can be estimated. A common transformation used is the natural logarithm. The reliability of environmental sampling of fecal slurry on freestall pens has been estimated for Mycobacterium avium subsp. paratuberculosis using the natural logarithm transformed culture results. Recently, the negative binomial ICC was defined based on a generalized linear mixed model for negative binomial distributed data. The current study reports on the negative binomial ICC estimate which includes fixed effects using culture results of environmental samples. Simulations using a wide variety of inputs and negative binomial distribution parameters (r; p) showed better performance of the new negative binomial ICC compared to the ICC based on LMM even when negative binomial data was logarithm, and square root transformed. A second comparison that targeted a wider range of ICC values showed that the mean of estimated ICC closely approximated the true ICC.

  1. Assessing the Validity of Single-item Life Satisfaction Measures: Results from Three Large Samples

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E.

    2014-01-01

    Purpose The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS) - a more psychometrically established measure. Methods Two large samples from Washington (N=13,064) and Oregon (N=2,277) recruited by the Behavioral Risk Factor Surveillance System (BRFSS) and a representative German sample (N=1,312) recruited by the Germany Socio-Economic Panel (GSOEP) were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Results Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62 – 0.64; disattenuated r = 0.78 – 0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001 – 0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS were very small (average absolute difference = 0.015 −0.042). Conclusions Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use. PMID:24890827

  2. Analytical results from Tank 38H criticality Sample HTF-093

    International Nuclear Information System (INIS)

    Wilmarth, W.R.

    2000-01-01

    Resumption of processing in the 242-16H Evaporator could cause salt dissolution in the Waste Concentration Receipt Tank (Tank 38H). Therefore, High Level Waste personnel sampled the tank at the salt surface. Results of elemental analysis of the dried sludge solids from this sample (HTF-093) show significant quantities of neutron poisons (i.e., sodium, iron, and manganese) present to mitigate the potential for nuclear criticality. Comparison of this sample with the previous chemical and radiometric analyses of H-Area Evaporator samples show high poison to actinide ratios

  3. Females' sampling strategy to comparatively evaluate prospective mates in the peacock blenny Salaria pavo

    Science.gov (United States)

    Locatello, Lisa; Rasotto, Maria B.

    2017-08-01

    Emerging evidence suggests the occurrence of comparative decision-making processes in mate choice, questioning the traditional idea of female choice based on rules of absolute preference. In such a scenario, females are expected to use a typical best-of- n sampling strategy, being able to recall previous sampled males based on memory of their quality and location. Accordingly, the quality of preferred mate is expected to be unrelated to both the number and the sequence of female visits. We found support for these predictions in the peacock blenny, Salaria pavo, a fish where females have the opportunity to evaluate the attractiveness of many males in a short time period and in a restricted spatial range. Indeed, even considering the variability in preference among females, most of them returned to previous sampled males for further evaluations; thus, the preferred male did not represent the last one in the sequence of visited males. Moreover, there was no relationship between the attractiveness of the preferred male and the number of further visits assigned to the other males. Our results suggest the occurrence of a best-of- n mate sampling strategy in the peacock blenny.

  4. Comparison of leach results from field and laboratory prepared samples

    International Nuclear Information System (INIS)

    Oblath, S.B.; Langton, C.A.

    1985-01-01

    The leach behavior of saltstone prepared in the laboratory agrees well with that from samples mixed in the field using the Littleford mixer. Leach rates of nitrates and cesium from the current reference formulation saltstone were compared. The laboratory samples were prepared using simulated salt solution; those in the field used Tank 50 decontaminated supernate. For both nitrate and cesium, the field and laboratory samples showed nearly identical leach rates for the first 30 to 50 days. For the remaining period of the test, the field samples showed higher leach rates with the maximum difference being less than a factor of three. Ruthenium and antimony were present in the Tank 50 supernate in known amounts. Antimony-125 was observed in the leachate and a fractional leach rate was calculated to be at least a factor of ten less than that of 137 Cs. No 106 Ru was observed in the leachate, and the release rate was not calculated. However, based on the detection limits for the analysis, the ruthenium leach rate must also be at least a factor of ten less than cesium. These data are the first measurements of the leach rates of Ru and Sb from saltstone. The nitrate leach rates for these samples were 5 x 10 -5 grams of nitrate per square cm per day after 100 days for the laboratory samples and after 200 days for the field samples. These values are consistent with the previously measured leach rates for reference formulation saltstone. The relative standard deviation in the leach rate is about 15% for the field samples, which all were produced from one batch of saltstone, and about 35% for the laboratory samples, which came from different batches. These are the first recorded estimates of the error in leach rates for saltstone

  5. Comparing Server Energy Use and Efficiency Using Small Sample Sizes

    Energy Technology Data Exchange (ETDEWEB)

    Coles, Henry C.; Qin, Yong; Price, Phillip N.

    2014-11-01

    This report documents a demonstration that compared the energy consumption and efficiency of a limited sample size of server-type IT equipment from different manufacturers by measuring power at the server power supply power cords. The results are specific to the equipment and methods used. However, it is hoped that those responsible for IT equipment selection can used the methods described to choose models that optimize energy use efficiency. The demonstration was conducted in a data center at Lawrence Berkeley National Laboratory in Berkeley, California. It was performed with five servers of similar mechanical and electronic specifications; three from Intel and one each from Dell and Supermicro. Server IT equipment is constructed using commodity components, server manufacturer-designed assemblies, and control systems. Server compute efficiency is constrained by the commodity component specifications and integration requirements. The design freedom, outside of the commodity component constraints, provides room for the manufacturer to offer a product with competitive efficiency that meets market needs at a compelling price. A goal of the demonstration was to compare and quantify the server efficiency for three different brands. The efficiency is defined as the average compute rate (computations per unit of time) divided by the average energy consumption rate. The research team used an industry standard benchmark software package to provide a repeatable software load to obtain the compute rate and provide a variety of power consumption levels. Energy use when the servers were in an idle state (not providing computing work) were also measured. At high server compute loads, all brands, using the same key components (processors and memory), had similar results; therefore, from these results, it could not be concluded that one brand is more efficient than the other brands. The test results show that the power consumption variability caused by the key components as a

  6. Results Of Analytical Sample Crosschecks For Next Generation Solvent Extraction Samples Isopar L Concentration And pH

    International Nuclear Information System (INIS)

    Peters, T.; Fink, S.

    2011-01-01

    As part of the implementation process for the Next Generation Cesium Extraction Solvent (NGCS), SRNL and F/H Lab performed a series of analytical cross-checks to ensure that the components in the NGCS solvent system do not constitute an undue analytical challenge. For measurement of entrained Isopar(reg s ign) L in aqueous solutions, both labs performed similarly with results more reliable at higher concentrations (near 50 mg/L). Low bias occurred in both labs, as seen previously for comparable blind studies for the baseline solvent system. SRNL recommends consideration to use of Teflon(trademark) caps on all sample containers used for this purpose. For pH measurements, the labs showed reasonable agreement but considerable positive bias for dilute boric acid solutions. SRNL recommends consideration of using an alternate analytical method for qualification of boric acid concentrations.

  7. Results with commercial radioassay kits compared with microbiological assay of folate in serum and whole-blood

    International Nuclear Information System (INIS)

    McGown, E.L.; Lewis, C.M.; Dong, M.H.; Sauberlich, H.E.

    1978-01-01

    Results with three commercial folate radioassay kits [Bio-Rad, New England Nuclear (NEN), and RIA Products] were compared with those by microbiological assay for more than 200 samples of human serum and whole blood. All but one kit (NEN) compared favorably with the microbiological assay for serum samples, although there were notable diagnostic discrepancies. Two kits (NEN and Bio-Rad) were tested on whole-blood samples; both yielded values significantly higher than those by microbiological assay. The frequency distributions of erythrocyte folate data differed strikingly between the two kits; the NEN method yielded a much narrower range of normal values than did either the Bio-Rad or the microbiological assay. Radioassay kits appear to be suitable diagnostic agents for serum folate, if the behavior of a particular kit is investigated thoroughly before its routine use. However, the diagnostic value of radioassays of erythrocyte folate needs to be validated

  8. Exploring Technostress: Results of a Large Sample Factor Analysis

    OpenAIRE

    Jonušauskas, Steponas; Raišienė, Agota Giedrė

    2016-01-01

    With reference to the results of a large sample factor analysis, the article aims to propose the frame examining technostress in a population. The survey and principal component analysis of the sample consisting of 1013 individuals who use ICT in their everyday work was implemented in the research. 13 factors combine 68 questions and explain 59.13 per cent of the answers dispersion. Based on the factor analysis, questionnaire was reframed and prepared to reasonably analyze the respondents’ an...

  9. Delayed Measurement of Eosin-5'-Maleimide Binding May Affect the Test Results of Highly Hemolyzed Samples In Vivo and In Vitro-A Case Study.

    Science.gov (United States)

    Ciepiela, Olga; Adamowicz-Salach, Anna; Zdziechowicz, Izabela; Kotuła, Iwona

    2016-11-01

    Diagnosis of hereditary spherocytosis (HS) is based on clinical evaluation and eosin-5'-maleimide (EMA) test. A decrease in EMA fluorescence compared with healthy individuals is typical for HS and serves as a basis for HS diagnosis. Sensitivity and specificity of the test is high and false-positive results rarely occur. Studies have shown that anticoagulated blood sample when stored at 4°C for 7 days do not affect the test results. This case study is about an autoimmune hemolytic anemia patient who showed a primary positive result for EMA test (decrease in EMA fluorescence-47% compared with 100% for samples of healthy individual), when the test was performed in the sample stored for 48 hours after venipuncture and before staining. An irrelevant decrease (92.5% compared with 100% for samples of healthy individual) was found when freshly collected sample was analyzed. On the basis of the results obtained, it is recommended that EMA staining should be performed on the same day of blood collection for patients with significant hemolysis.

  10. Comparative Analysis of Results of Online and Offline Customer Satisfaction

    Directory of Open Access Journals (Sweden)

    Jovović Milorad

    2017-05-01

    Full Text Available The logic that customer satisfaction is the starting point of marketing and business activities is based on the assumption that customer satisfaction leads to customer loyalty, keeping in mind all of the positive effects that customer loyalty has on business success of an organization. Because of this, marketing and management theory and practice dedicate particular attention to the concepts of customer satisfaction and loyalty. In this paper we will use the surveys of customers of banking services not only to show the levels of their satisfaction and loyalty, but also to make a comparative analysis of data obtained through online and offline research. This approach was made possible because the research was carried out on a sample which was divided in two groups. All of the participants answered the questions from a unique questionnaire, however, one group took the survey via the Internet (online while data from the other group of participants was collected in the field by using printed questionnaires (offline. The findings of the comparative analysis of online and offline survey results are presented in the final part of the paper.

  11. Results of EDS uranium samples characterization after hydrogen loading

    International Nuclear Information System (INIS)

    Chicea, D.; Dash, J.

    2003-01-01

    Several experiments of loading natural uranium foils with hydrogen were done. Electrolysis was used for loading hydrogen into uranium, because it is the most efficient way for H loading. The composition of the surface and near surface of the samples was determined using an Oxford EDS spectrometer on a Scanning Electron Microscope, manufactured by ISI. Images were taken with several magnifications up to 3.4KX. Results reveal that when low current density was used, the surface patterns changed from granules on the surface having a typical size of 2-4 microns to pits under the surface having a typical size under one micron. When high current density was used the surface changed and presented deep fissures. The deep fissures are the result of the mechanical strain induced by the lattice expansion caused by hydrogen absorption. The surface composition was determined before and after hydrogen loading. Uranium, thorium platinum and carbon concentration were measured. Experiments suggest that the amount of thorium increases on the uranium sample with the total electric charge transported through electrolyte. Carbon concentration was found to decrease on the surface of the sample as the total electric charge transported through electrolyte increased. Platinum is used in electrolysis experiment as anode primarily because it does not dissolve in electrolyte and therefore it is not electro-deposited on the cathode surface. The results of the platinum concentration measurements on the surface of the samples we loaded with hydrogen reveal that the platinum concentration increased dramatically as the current density increased and that created platinum spots on the cathode surface. Work is in progress on the subject. (authors)

  12. Comparative value of blood and skin samples for diagnosis of spotted fever group rickettsial infection in model animals.

    Science.gov (United States)

    Levin, Michael L; Snellgrove, Alyssa N; Zemtsova, Galina E

    2016-07-01

    The definitive diagnosis of spotted fever group (SFG) rickettsioses in humans is challenging due to the retrospective nature and cross reactivity of the serological methods and the absence of reliable and consistent samples for molecular diagnostics. Existing data indicate the transient character of bacteremia in experimentally infected animals. The ability of arthropod vectors to acquire rickettsial infection from the laboratory animals in the absence of systemic infection and known tropism of rickettsial agents to endothelial cells of peripheral blood vessels underline the importance of local infection and consequently the diagnostic potential of skin samples. In order to evaluate the diagnostic sensitivity of rickettsial DNA detection in blood and skin samples, we compared results of PCR testing in parallel samples collected from model laboratory animals infected with Rickettsia rickettsii, Rickettsia parkeri and Rickettsia slovaca-like agent at different time points after infection. Skin samples were collected from ears - away from the site of tick placement and without eschars. Overall, testing of skin samples resulted in a higher proportion of positive results than testing of blood samples. Presented data from model animals demonstrates that testing of skin samples from sites of rickettsial proliferation can provide definitive molecular diagnosis of up to 60-70% of tick-borne SFG rickettsial infections during the acute stage of illness. Detection of pathogen DNA in cutaneous samples is a valuable alternative to blood-PCR at least in model animals. Published by Elsevier GmbH.

  13. Results of tritium measurement in environmental samples and drainage

    International Nuclear Information System (INIS)

    Koike, Ryoji; Hirai, Yasuo

    1983-01-01

    In Ibaraki prefecture, the tritium concentration in the drainage from the nuclear facilities has been measured since 1974. Then, with the start of operation of the fuel reprocessing plant in 1977, the tritium concentration in environmental samples was to be measured also in order to examine the effect of the drainage on the environment. The results of the tritium measurement in Ibaraki prefecture up to about 1980 are described: sampling points, sampling and measuring methods, the tritium concentration in the drainage, air, inland water and seawater, respectively. The drainages have been taken from Japan Atomic Power Company, Japan Atomic Energy Research Institute, and Power Reactor and Nuclear Fuel Development Corporation (with the fuel reprocessing plant). The samples of air, inland water and seawater have been taken in the areas concerned. The tritium concentration was measured by a low-background liquid scintillation counter. The measured values in the environment have been generally at low level, not different from other areas. (Mori, K.)

  14. Comparing Results from Constant Comparative and Computer Software Methods: A Reflection about Qualitative Data Analysis

    Science.gov (United States)

    Putten, Jim Vander; Nolen, Amanda L.

    2010-01-01

    This study compared qualitative research results obtained by manual constant comparative analysis with results obtained by computer software analysis of the same data. An investigated about issues of trustworthiness and accuracy ensued. Results indicated that the inductive constant comparative data analysis generated 51 codes and two coding levels…

  15. Tank 214-AW-105, grab samples, analytical results for the final report

    International Nuclear Information System (INIS)

    Esch, R.A.

    1997-01-01

    This document is the final report for tank 241-AW-105 grab samples. Twenty grabs samples were collected from risers 10A and 15A on August 20 and 21, 1996, of which eight were designated for the K Basin sludge compatibility and mixing studies. This document presents the analytical results for the remaining twelve samples. Analyses were performed in accordance with the Compatibility Grab Sampling and Analysis Plan (TSAP) and the Data Quality Objectives for Tank Farms Waste Compatibility Program (DO). The results for the previous sampling of this tank were reported in WHC-SD-WM-DP-149, Rev. 0, 60-Day Waste Compatibility Safety Issue and Final Results for Tank 241-A W-105, Grab Samples 5A W-95-1, 5A W-95-2 and 5A W-95-3. Three supernate samples exceeded the TOC notification limit (30,000 microg C/g dry weight). Appropriate notifications were made. No immediate notifications were required for any other analyte. The TSAP requested analyses for polychlorinated biphenyls (PCB) for all liquids and centrifuged solid subsamples. The PCB analysis of the liquid samples has been delayed and will be presented in a revision to this document

  16. Comparing the effects of community service and imprisonment on reconviction: results from a quasi-experimental Danish study

    DEFF Research Database (Denmark)

    Klement, Christian

    2015-01-01

    Objective This study compares reconviction rates for Danish offenders sentenced to community service and imprisonment. A large general sample of offenders (n = 1602) is examined. Methods The study relies on a quasi-experimental design and uses propensity score matching as well as logistic....... Results Imprisonment is associated with a higher rate of recidivism and the result is statistically significant at conventional statistical levels. Conclusions Community service (CS) compared to imprisonment appears to cause a lower reconviction rate in general. Additional research is needed to shed light...

  17. Tank 241-SY-102 January 2000 Compatibility Grab Samples Analytical Results for the Final Report [SEC 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    BELL, K.E.

    2000-05-11

    This document is the format IV, final report for the tank 241-SY-102 (SY-102) grab samples taken in January 2000 to address waste compatibility concerns. Chemical, radiochemical, and physical analyses on the tank SY-102 samples were performed as directed in Comparability Grab Sampling and Analysis Plan for Fiscal Year 2000 (Sasaki 1999). No notification limits were exceeded. Preliminary data on samples 2SY-99-5, -6, and -7 were reported in ''Format II Report on Tank 241-SY-102 Waste Compatibility Grab Samples Taken in January 2000'' (Lockrem 2000). The data presented here represent the final results.

  18. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  19. The prevalence of discrimination across racial groups in contemporary America: Results from a nationally representative sample of adults.

    Directory of Open Access Journals (Sweden)

    Brian B Boutwell

    Full Text Available A large body of social science research is devoted to understanding the causes and correlates of discrimination. Comparatively less effort has been aimed at providing a general prevalence estimate of discrimination using a nationally representative sample. The current study is intended to offer such an estimate using a large sample of American respondents (N = 14,793 while also exploring perceptions regarding why respondents felt they were discriminated against. The results provide a broad estimate of self-reported discrimination experiences-an event that was only reported by about one-quarter of all sample members-across racial and ethnic categories.

  20. The prevalence of discrimination across racial groups in contemporary America: Results from a nationally representative sample of adults

    Science.gov (United States)

    Nedelec, Joseph L.; Winegard, Bo; Shackelford, Todd; Beaver, Kevin M.; Vaughn, Michael; Barnes, J. C.; Wright, John P.

    2017-01-01

    A large body of social science research is devoted to understanding the causes and correlates of discrimination. Comparatively less effort has been aimed at providing a general prevalence estimate of discrimination using a nationally representative sample. The current study is intended to offer such an estimate using a large sample of American respondents (N = 14,793) while also exploring perceptions regarding why respondents felt they were discriminated against. The results provide a broad estimate of self-reported discrimination experiences—an event that was only reported by about one-quarter of all sample members—across racial and ethnic categories. PMID:28837680

  1. Testing results of Monte Carlo sampling processes in MCSAD

    International Nuclear Information System (INIS)

    Pinnera, I.; Cruz, C.; Abreu, Y.; Leyva, A.; Correa, C.; Demydenko, C.

    2009-01-01

    The Monte Carlo Simulation of Atom Displacements (MCSAD) is a code implemented by the authors to simulate the complete process of atom displacement (AD) formation. This code makes use of the Monte Carlo (MC) method to sample all the processes involved in the gamma and electronic radiation transport through matter. The kernel of the calculations applied to this code relies on a model based on an algorithm developed by the authors, which firstly splits out multiple electron elastic scattering events from those single ones at higher scattering angles and then, from the last one, sampling those leading to AD at high transferred atomic recoil energies. Some tests have been developed to check the sampling algorithms with the help of the corresponding theoretical distribution functions. Satisfactory results have been obtained, which indicate the strength of the methods and subroutines used in the code. (Author)

  2. Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Casey, Cameron P. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Stratton, Kelly G. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zink, Erika M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Kim, Young-Mo [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zheng, Xueyun [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Monroe, Matthew E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Weitz, Karl K. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Bloodsworth, Kent J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Orton, Daniel J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Ibrahim, Yehia M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Moore, Ronald J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Lee, Christine G. [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Research Service, Portland Veterans Affairs Medical Center, Portland OR USA; Pedersen, Catherine [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Orwoll, Eric [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Smith, Richard D. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Burnum-Johnson, Kristin E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Baker, Erin S. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA

    2017-02-05

    The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

  3. Sample preparation methods for scanning electron microscopy of homogenized Al-Mg-Si billets: A comparative study

    International Nuclear Information System (INIS)

    Österreicher, Johannes Albert; Kumar, Manoj; Schiffl, Andreas; Schwarz, Sabine; Hillebrand, Daniel; Bourret, Gilles Remi

    2016-01-01

    Characterization of Mg-Si precipitates is crucial for optimizing the homogenization heat treatment of Al-Mg-Si alloys. Although sample preparation is key for high quality scanning electron microscopy imaging, most common methods lead to dealloying of Mg-Si precipitates. In this article we systematically evaluate different sample preparation methods: mechanical polishing, etching with various reagents, and electropolishing using different electrolytes. We demonstrate that the use of a nitric acid and methanol electrolyte for electropolishing a homogenized Al-Mg-Si alloy prevents the dissolution of Mg-Si precipitates, resulting in micrographs of higher quality. This preparation method is investigated in depth and the obtained scanning electron microscopy images are compared with transmission electron micrographs: the shape and size of Mg-Si precipitates appear very similar in either method. The scanning electron micrographs allow proper identification and measurement of the Mg-Si phases including needles with lengths of roughly 200 nm. These needles are β″ precipitates as confirmed by high resolution transmission electron microscopy. - Highlights: •Secondary precipitation in homogenized 6xxx Al alloys is crucial for extrudability. •Existing sample preparation methods for SEM are improvable. •Electropolishing with nitric acid/methanol yields superior quality in SEM. •The obtained micrographs are compared to TEM micrographs.

  4. Sample preparation methods for scanning electron microscopy of homogenized Al-Mg-Si billets: A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Österreicher, Johannes Albert; Kumar, Manoj [LKR Light Metals Technologies Ranshofen, Austrian Institute of Technology, Postfach 26, 5282 Ranshofen (Austria); Schiffl, Andreas [Hammerer Aluminium Industries Extrusion GmbH, Lamprechtshausener Straße 69, 5282 Ranshofen (Austria); Schwarz, Sabine [University Service Centre for Transmission Electron Microscopy, Vienna University of Technology, Wiedner Hauptstr. 8-10, 1040 Wien (Austria); Hillebrand, Daniel [Hammerer Aluminium Industries Extrusion GmbH, Lamprechtshausener Straße 69, 5282 Ranshofen (Austria); Bourret, Gilles Remi, E-mail: gilles.bourret@sbg.ac.at [Department of Materials Science and Physics, University of Salzburg, Hellbrunner Straße 34, 5020 Salzburg (Austria)

    2016-12-15

    Characterization of Mg-Si precipitates is crucial for optimizing the homogenization heat treatment of Al-Mg-Si alloys. Although sample preparation is key for high quality scanning electron microscopy imaging, most common methods lead to dealloying of Mg-Si precipitates. In this article we systematically evaluate different sample preparation methods: mechanical polishing, etching with various reagents, and electropolishing using different electrolytes. We demonstrate that the use of a nitric acid and methanol electrolyte for electropolishing a homogenized Al-Mg-Si alloy prevents the dissolution of Mg-Si precipitates, resulting in micrographs of higher quality. This preparation method is investigated in depth and the obtained scanning electron microscopy images are compared with transmission electron micrographs: the shape and size of Mg-Si precipitates appear very similar in either method. The scanning electron micrographs allow proper identification and measurement of the Mg-Si phases including needles with lengths of roughly 200 nm. These needles are β″ precipitates as confirmed by high resolution transmission electron microscopy. - Highlights: •Secondary precipitation in homogenized 6xxx Al alloys is crucial for extrudability. •Existing sample preparation methods for SEM are improvable. •Electropolishing with nitric acid/methanol yields superior quality in SEM. •The obtained micrographs are compared to TEM micrographs.

  5. Organic analysis of ambient samples collected near Tank 241-C-103: Results from samples collected on May 12, 1994

    International Nuclear Information System (INIS)

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Lucke, R.B.; Young, J.S.; McCulloch, M.; Fruchter, J.S.; Goheen, S.C.

    1995-06-01

    This report describes organic analyses results from ambient samples collected both upwind and through the vapor sampling system (VSS) near Hanford waste storage Tank 241-C-103 (referred to as Tank C-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Quantitative results were obtained for organic compounds. Five organic tentatively identified compounds (TICS) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, we looked for the 40 standard TO-14 analytes. We observed 39. Of these, only one was observed above the 2-ppbv calibrated instrument detection limit. Dichloromethane was above the detection limits using both methods, but the result from the TO-14 method is traceable to a standard gas mixture and is considered more accurate. Organic analytes were found only in the sample collected through the VSS, suggesting that these compounds were residual contamination from a previous sampling job. Detailed descriptions of the results appear in the text

  6. Estimation of AUC or Partial AUC under Test-Result-Dependent Sampling.

    Science.gov (United States)

    Wang, Xiaofei; Ma, Junling; George, Stephen; Zhou, Haibo

    2012-01-01

    The area under the ROC curve (AUC) and partial area under the ROC curve (pAUC) are summary measures used to assess the accuracy of a biomarker in discriminating true disease status. The standard sampling approach used in biomarker validation studies is often inefficient and costly, especially when ascertaining the true disease status is costly and invasive. To improve efficiency and reduce the cost of biomarker validation studies, we consider a test-result-dependent sampling (TDS) scheme, in which subject selection for determining the disease state is dependent on the result of a biomarker assay. We first estimate the test-result distribution using data arising from the TDS design. With the estimated empirical test-result distribution, we propose consistent nonparametric estimators for AUC and pAUC and establish the asymptotic properties of the proposed estimators. Simulation studies show that the proposed estimators have good finite sample properties and that the TDS design yields more efficient AUC and pAUC estimates than a simple random sampling (SRS) design. A data example based on an ongoing cancer clinical trial is provided to illustrate the TDS design and the proposed estimators. This work can find broad applications in design and analysis of biomarker validation studies.

  7. [Comparative studies of personal and steady-state sampling for determining dust exposure in different job groups].

    Science.gov (United States)

    Cherneva, P; Lukanova, R

    1994-01-01

    The variability of the dust concentration in time and space, as well as the change of worker's place during the working process, define the necessity of introducing personal sampling in the hygiene control practice. However, the laboratory equipment with personal devices is still not sufficient. The aim of this work is to assess the dust exposure of the basic professional groups from the ore- and coal production in Bulgaria by personal sampling in comparative studies of the static ambient sampling used up to now. 63 full-shift investigations of the dust factor were performed on professional groups of miners of the polymetal and coal pits by static ambient devices-[Hygitest production] and personal [from firms "Casella", "Strolein" and "Gilian"] devices, after standardized methods. The results are data processed-by means of logarithmic normal distribution of the relation of the respirable dust concentrations, determined personally and by static ambient sampling. The limits of variation of this correlation are from 0.5 to 4.1 at average geometric value -0.95 and standard geometric deviation-1.8 i.e. both types of sampling are intersubstitutional for the examined groups and sites, as in the underground ores the professional risk of respirable dust is underestimated up to 4 times at static ambient sampling.

  8. Sample size for comparing negative binomial rates in noninferiority and equivalence trials with unequal follow-up times.

    Science.gov (United States)

    Tang, Yongqiang

    2017-05-25

    We derive the sample size formulae for comparing two negative binomial rates based on both the relative and absolute rate difference metrics in noninferiority and equivalence trials with unequal follow-up times, and establish an approximate relationship between the sample sizes required for the treatment comparison based on the two treatment effect metrics. The proposed method allows the dispersion parameter to vary by treatment groups. The accuracy of these methods is assessed by simulations. It is demonstrated that ignoring the between-subject variation in the follow-up time by setting the follow-up time for all individuals to be the mean follow-up time may greatly underestimate the required size, resulting in underpowered studies. Methods are provided for back-calculating the dispersion parameter based on the published summary results.

  9. Sample similarity analysis of angles of repose based on experimental results for DEM calibration

    Science.gov (United States)

    Tan, Yuan; Günthner, Willibald A.; Kessler, Stephan; Zhang, Lu

    2017-06-01

    As a fundamental material property, particle-particle friction coefficient is usually calculated based on angle of repose which can be obtained experimentally. In the present study, the bottomless cylinder test was carried out to investigate this friction coefficient of a kind of biomass material, i.e. willow chips. Because of its irregular shape and varying particle size distribution, calculation of the angle becomes less applicable and decisive. In the previous studies only one section of those uneven slopes is chosen in most cases, although standard methods in definition of a representable section are barely found. Hence, we presented an efficient and reliable method from the new technology, 3D scan, which was used to digitize the surface of heaps and generate its point cloud. Then, two tangential lines of any selected section were calculated through the linear least-squares regression (LLSR), such that the left and right angle of repose of a pile could be derived. As the next step, a certain sum of sections were stochastic selected, and calculations were repeated correspondingly in order to achieve sample of angles, which was plotted in Cartesian coordinates as spots diagram. Subsequently, different samples were acquired through various selections of sections. By applying similarities and difference analysis of these samples, the reliability of this proposed method was verified. Phased results provides a realistic criterion to reduce the deviation between experiment and simulation as a result of random selection of a single angle, which will be compared with the simulation results in the future.

  10. Sample similarity analysis of angles of repose based on experimental results for DEM calibration

    Directory of Open Access Journals (Sweden)

    Tan Yuan

    2017-01-01

    Full Text Available As a fundamental material property, particle-particle friction coefficient is usually calculated based on angle of repose which can be obtained experimentally. In the present study, the bottomless cylinder test was carried out to investigate this friction coefficient of a kind of biomass material, i.e. willow chips. Because of its irregular shape and varying particle size distribution, calculation of the angle becomes less applicable and decisive. In the previous studies only one section of those uneven slopes is chosen in most cases, although standard methods in definition of a representable section are barely found. Hence, we presented an efficient and reliable method from the new technology, 3D scan, which was used to digitize the surface of heaps and generate its point cloud. Then, two tangential lines of any selected section were calculated through the linear least-squares regression (LLSR, such that the left and right angle of repose of a pile could be derived. As the next step, a certain sum of sections were stochastic selected, and calculations were repeated correspondingly in order to achieve sample of angles, which was plotted in Cartesian coordinates as spots diagram. Subsequently, different samples were acquired through various selections of sections. By applying similarities and difference analysis of these samples, the reliability of this proposed method was verified. Phased results provides a realistic criterion to reduce the deviation between experiment and simulation as a result of random selection of a single angle, which will be compared with the simulation results in the future.

  11. Empirically simulated study to compare and validate sampling methods used in aerial surveys of wildlife populations

    NARCIS (Netherlands)

    Khaemba, W.M.; Stein, A.; Rasch, D.; Leeuw, de J.; Georgiadis, N.

    2001-01-01

    This paper compares the distribution, sampling and estimation of abundance for two animal species in an African ecosystem by means of an intensive simulation of the sampling process under a geographical information system (GIS) environment. It focuses on systematic and random sampling designs,

  12. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study.

    Science.gov (United States)

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda

    2018-01-01

    Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.

  13. Research results: preserving newborn blood samples.

    Science.gov (United States)

    Lewis, Michelle Huckaby; Scheurer, Michael E; Green, Robert C; McGuire, Amy L

    2012-11-07

    Retention and use, without explicit parental permission, of residual dried blood samples from newborn screening has generated public controversy over concerns about violations of family privacy rights and loss of parental autonomy. The public debate about this issue has included little discussion about the destruction of a potentially valuable public resource that can be used for research that may yield improvements in public health. The research community must advocate for policies and infrastructure that promote retention of residual dried blood samples and their use in biomedical research.

  14. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1995-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques. (author) 7 refs.; 5 tabs

  15. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1994-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques

  16. SAMPLE RESULTS FROM THE INTEGRATED SALT DISPOSITION PROGRAM MACROBATCH 5 TANK 21H QUALIFICATION MST, ESS AND PODD SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T.; Fink, S.

    2012-04-24

    Savannah River National Laboratory (SRNL) performed experiments on qualification material for use in the Integrated Salt Disposition Program (ISDP) Batch 5 processing. This qualification material was a composite created from recent samples from Tank 21H and archived samples from Tank 49H to match the projected blend from these two tanks. Additionally, samples of the composite were used in the Actinide Removal Process (ARP) and extraction-scrub-strip (ESS) tests. ARP and ESS test results met expectations. A sample from Tank 21H was also analyzed for the Performance Objectives Demonstration Document (PODD) requirements. SRNL was able to meet all of the requirements, including the desired detection limits for all the PODD analytes. This report details the results of the Actinide Removal Process (ARP), Extraction-Scrub-Strip (ESS) and Performance Objectives Demonstration Document (PODD) samples of Macrobatch (Salt Batch) 5 of the Integrated Salt Disposition Program (ISDP).

  17. Effect of Different Sampling Schedules on Results of Bioavailability and Bioequivalence Studies: Evaluation by Means of Monte Carlo Simulations.

    Science.gov (United States)

    Kano, Eunice Kazue; Chiann, Chang; Fukuda, Kazuo; Porta, Valentina

    2017-08-01

    Bioavailability and bioequivalence study is one of the most frequently performed investigations in clinical trials. Bioequivalence testing is based on the assumption that 2 drug products will be therapeutically equivalent when they are equivalent in the rate and extent to which the active drug ingredient or therapeutic moiety is absorbed and becomes available at the site of drug action. In recent years there has been a significant growth in published papers that use in silico studies based on mathematical simulations to analyze pharmacokinetic and pharmacodynamic properties of drugs, including bioavailability and bioequivalence aspects. The goal of this study is to evaluate the usefulness of in silico studies as a tool in the planning of bioequivalence, bioavailability and other pharmacokinetic assays, e.g., to determine an appropriate sampling schedule. Monte Carlo simulations were used to define adequate blood sampling schedules for a bioequivalence assay comparing 2 different formulations of cefadroxil oral suspensions. In silico bioequivalence studies comparing different formulation of cefadroxil oral suspensions using various sampling schedules were performed using models. An in vivo study was conducted to confirm in silico results. The results of in silico and in vivo bioequivalence studies demonstrated that schedules with fewer sampling times are as efficient as schedules with larger numbers of sampling times in the assessment of bioequivalence, but only if T max is included as a sampling time. It was also concluded that in silico studies are useful tools in the planning of bioequivalence, bioavailability and other pharmacokinetic in vivo assays. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Comparing two sampling methods to engage hard-to-reach communities in research priority setting

    Directory of Open Access Journals (Sweden)

    Melissa A. Valerio

    2016-10-01

    Full Text Available Abstract Background Effective community-partnered and patient-centered outcomes research needs to address community priorities. However, optimal sampling methods to engage stakeholders from hard-to-reach, vulnerable communities to generate research priorities have not been identified. Methods In two similar rural, largely Hispanic communities, a community advisory board guided recruitment of stakeholders affected by chronic pain using a different method in each community: 1 snowball sampling, a chain- referral method or 2 purposive sampling to recruit diverse stakeholders. In both communities, three groups of stakeholders attended a series of three facilitated meetings to orient, brainstorm, and prioritize ideas (9 meetings/community. Using mixed methods analysis, we compared stakeholder recruitment and retention as well as priorities from both communities’ stakeholders on mean ratings of their ideas based on importance and feasibility for implementation in their community. Results Of 65 eligible stakeholders in one community recruited by snowball sampling, 55 (85 % consented, 52 (95 % attended the first meeting, and 36 (65 % attended all 3 meetings. In the second community, the purposive sampling method was supplemented by convenience sampling to increase recruitment. Of 69 stakeholders recruited by this combined strategy, 62 (90 % consented, 36 (58 % attended the first meeting, and 26 (42 % attended all 3 meetings. Snowball sampling recruited more Hispanics and disabled persons (all P < 0.05. Despite differing recruitment strategies, stakeholders from the two communities identified largely similar ideas for research, focusing on non-pharmacologic interventions for management of chronic pain. Ratings on importance and feasibility for community implementation differed only on the importance of massage services (P = 0.045 which was higher for the purposive/convenience sampling group and for city improvements

  19. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    Science.gov (United States)

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.

  20. Evaluation of analytical results on DOE Quality Assessment Program Samples

    International Nuclear Information System (INIS)

    Jaquish, R.E.; Kinnison, R.R.; Mathur, S.P.; Sastry, R.

    1985-01-01

    Criteria were developed for evaluating the participants analytical results in the DOE Quality Assessment Program (QAP). Historical data from previous QAP studies were analyzed using descriptive statistical methods to determine the interlaboratory precision that had been attained. Performance criteria used in other similar programs were also reviewed. Using these data, precision values and control limits were recommended for each type of analysis performed in the QA program. Results of the analysis performed by the QAP participants on the November 1983 samples were statistically analyzed and evaluated. The Environmental Measurements Laboratory (EML) values were used as the known values and 3-sigma precision values were used as control limits. Results were submitted by 26 participating laboratories for 49 different radionuclide media combinations. The participants reported 419 results and of these, 350 or 84% were within control limits. Special attention was given to the data from gamma spectral analysis of air filters and water samples. both normal probability and box plots were prepared for each nuclide to help evaluate the distribution of the data. Results that were outside the expected range were identified and suggestions made that laboratories check calculations, and procedures on these results

  1. Effect of blood contamination on results of dipstick evaluation and urine protein-to-urine creatinine ratio for urine samples from dogs and cats.

    Science.gov (United States)

    Vientós-Plotts, Aida I; Behrend, Ellen N; Welles, Elizabeth G; Chew, Dennis J; Gaillard, Philippe R; Busler, Jessica N; Lee, Hollie P

    2018-05-01

    OBJECTIVE To evaluate effects of blood contamination on dipstick results, specific gravity (SG), and urine protein-to-urine creatinine ratio (UPCR) for urine samples from dogs and cats. SAMPLE Urine samples collected from 279 dogs and 120 cats. PROCEDURES Urine pools were made for each species (dogs [n = 60] and cats [30]). Blood was added to an aliquot of a pool, and serial dilutions were prepared with the remaining urine. Color and dipstick variables were recorded, and SG and UPCR were measured. For cats, 1 set of pools was used; for dogs, 2 sets were used. Comparisons were made between undiluted urine and spiked urine samples for individual colors. Repeated-measures ANOVA on ranks was used to compare dipstick scores and UPCR results; χ 2 tests were used to compare proteinuria categorizations (nonproteinuric, borderline, or proteinuric). RESULTS Any blood in the urine resulted in significantly increased dipstick scores for blood. In both species, scores for bilirubin and ketones, pH, and SG were affected by visible blood contamination. No significant difference for the dipstick protein reagent results was evident until a sample was visibly hematuric. The UPCR was significantly increased in dark yellow samples of both species. Proteinuria categorizations differed significantly between undiluted urine and urine of all colors, except light yellow. CONCLUSIONS AND CLINICAL RELEVANCE Any degree of blood contamination affected results of dipstick analysis. Effects depended on urine color and the variable measured. Microscopic blood contamination may affect the UPCR; thus, blood contamination may be a differential diagnosis for proteinuria in yellow urine samples.

  2. Comparing two survey methods of measuring health-related indicators: Lot Quality Assurance Sampling and Demographic Health Surveys.

    Science.gov (United States)

    Anoke, Sarah C; Mwai, Paul; Jeffery, Caroline; Valadez, Joseph J; Pagano, Marcello

    2015-12-01

    Two common methods used to measure indicators for health programme monitoring and evaluation are the demographic and health surveys (DHS) and lot quality assurance sampling (LQAS); each one has different strengths. We report on both methods when utilised in comparable situations. We compared 24 indicators in south-west Uganda, where data for prevalence estimations were collected independently for the two methods in 2011 (LQAS: n = 8876; DHS: n = 1200). Data were stratified (e.g. gender and age) resulting in 37 comparisons. We used a two-sample two-sided Z-test of proportions to compare both methods. The average difference between LQAS and DHS for 37 estimates was 0.062 (SD = 0.093; median = 0.039). The average difference among the 21 failures to reject equality of proportions was 0.010 (SD = 0.041; median = 0.009); among the 16 rejections, it was 0.130 (SD = 0.010, median = 0.118). Seven of the 16 rejections exhibited absolute differences of 0.10 and 0.20 (mean = 0.261, SD = 0.083). There is 75.7% agreement across the two surveys. Both methods yield regional results, but only LQAS provides information at less granular levels (e.g. the district level) where managerial action is taken. The cost advantage and localisation make LQAS feasible to conduct more frequently, and provides the possibility for real-time health outcomes monitoring. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  3. The Apollo lunar samples collection analysis and results

    CERN Document Server

    Young, Anthony

    2017-01-01

    This book focuses on the specific mission planning for lunar sample collection, the equipment used, and the analysis and findings concerning the samples at the Lunar Receiving Laboratory in Texas. Anthony Young documents the collection of Apollo samples for the first time for readers of all backgrounds, and includes interviews with many of those involved in planning and analyzing the samples. NASA contracted with the U.S. Geologic Survey to perform classroom and field training of the Apollo astronauts. NASA’s Geology Group within the Manned Spacecraft Center in Houston, Texas, helped to establish the goals of sample collection, as well as the design of sample collection tools, bags, and storage containers. In this book, detailed descriptions are given on the design of the lunar sampling tools, the Modular Experiment Transporter used on Apollo 14, and the specific areas of the Lunar Rover vehicle used for the Apollo 15, 16, and 17 missions, which carried the sampling tools, bags, and other related equipment ...

  4. Exploring Technostress: Results of a Large Sample Factor Analysis

    Directory of Open Access Journals (Sweden)

    Steponas Jonušauskas

    2016-06-01

    Full Text Available With reference to the results of a large sample factor analysis, the article aims to propose the frame examining technostress in a population. The survey and principal component analysis of the sample consisting of 1013 individuals who use ICT in their everyday work was implemented in the research. 13 factors combine 68 questions and explain 59.13 per cent of the answers dispersion. Based on the factor analysis, questionnaire was reframed and prepared to reasonably analyze the respondents’ answers, revealing technostress causes and consequences as well as technostress prevalence in the population in a statistically validated pattern. A key elements of technostress based on factor analysis can serve for the construction of technostress measurement scales in further research.

  5. [Comparability study of analytical results between a group of clinical laboratories].

    Science.gov (United States)

    Alsius-Serra, A; Ballbé-Anglada, M; López-Yeste, M L; Buxeda-Figuerola, M; Guillén-Campuzano, E; Juan-Pereira, L; Colomé-Mallolas, C; Caballé-Martín, I

    2015-01-01

    To describe the study of the comparability of the measurements levels of biological tests processed in biochemistry in Catlab's 4 laboratories. Quality requirements, coefficients of variation and total error (CV% and TE %) were established. Controls were verified with the precision requirements (CV%) in each test and each individual laboratory analyser. Fresh serum samples were used for the comparability study. The differences were analysed using a Microsoft Access® application that produces modified Bland-Altman plots. The comparison of 32 biological parameters that are performed in more than one laboratory and/or analyser generated 306 Bland-Altman graphs. Of these, 101 (33.1%) fell within the accepted range of values based on biological variability, and 205 (66.9%) required revision. Data were re-analysed based on consensus minimum specifications for analytical quality (consensus of the Asociación Española de Farmacéuticos Analistas (AEFA), the Sociedad Española de Bioquímica Clínica y Patología Molecular (SEQC), the Asociación Española de Biopatología Médica (AEBM) and the Sociedad Española de Hematología y Hemoterapia (SEHH), October 2013). With the new specifications, 170 comparisons (56%) fitted the requirements and 136 (44%) required additional review. Taking into account the number of points that exceeded the requirement, random errors, range of results in which discrepancies were detected, and range of clinical decision, it was shown that the 44% that required review were acceptable, and the 32 tests were comparable in all laboratories and analysers. The analysis of the results showed that the consensus requirements of the 4 scientific societies were met. However, each laboratory should aim to meet stricter criteria for total error. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  6. Non destructive multi elemental analysis using prompt gamma neutron activation analysis techniques: Preliminary results for concrete sample

    Energy Technology Data Exchange (ETDEWEB)

    Dahing, Lahasen Normanshah [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia and Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia); Yahya, Redzuan [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia); Yahya, Roslan; Hassan, Hearie [Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia)

    2014-09-03

    In this study, principle of prompt gamma neutron activation analysis has been used as a technique to determine the elements in the sample. The system consists of collimated isotopic neutron source, Cf-252 with HPGe detector and Multichannel Analysis (MCA). Concrete with size of 10×10×10 cm{sup 3} and 15×15×15 cm{sup 3} were analysed as sample. When neutrons enter and interact with elements in the concrete, the neutron capture reaction will occur and produce characteristic prompt gamma ray of the elements. The preliminary result of this study demonstrate the major element in the concrete was determined such as Si, Mg, Ca, Al, Fe and H as well as others element, such as Cl by analysis the gamma ray lines respectively. The results obtained were compared with NAA and XRF techniques as a part of reference and validation. The potential and the capability of neutron induced prompt gamma as tool for multi elemental analysis qualitatively to identify the elements present in the concrete sample discussed.

  7. Results of the Characterization and Dissolution Tests of Samples from Tank 16H

    International Nuclear Information System (INIS)

    Hay, M.S.

    1999-01-01

    Samples from Tank 16H annulus and one sample from the tank interior were characterized to provide a source term for use in fate and transport modeling. Four of the annulus samples appeared to be similar based on visual examination and were combined to form a composite. One of the annulus samples appeared to be different from the other four based on visual examination and was analyzed separately. The analytical results of the tank interior sample indicate the sample is composed predominantly of iron containing compounds. Both of the annulus samples are composed mainly of sodium salts, however, the composite sample contained significantly more sludge/sand material of low solubilitity. The characterization of the tank 16H annulus and tank interior samples was hampered by the high dose rate and the nature of the samples. The difficulties resulted in large uncertainties in the analytical data. The large uncertainties coupled with the number of important species below detection limits indicate the need for reanalysis of the Tank 16H samples as funding becomes available. Recommendations on potential remedies for these difficulties are provided. In general, none of the reagents appeared to be effective in dissolving the composite sample even after two contacts at elevated temperature. In contrast to the composite sample, all of the reagents dissolved a large percentage of the HTF-087 solids after two contacts at ambient temperature

  8. Comparative analysis of enzyme-linked immunosorbent assay and direct microscopy for the diagnosis of Giardia intestinalis in fecal samples

    Directory of Open Access Journals (Sweden)

    Shipra Singhal

    2015-01-01

    Full Text Available Context: Giardiasis is one of the most common nonviral infections causing diarrheal illness worldwide. In this prospective cross-sectional study, we evaluated the RIDASCREEN ® Giardia kit for detection of Giardia intestinalis in stool samples and compared the results with direct microscopy. Materials and methods: A total of 360 fecal samples were collected. They were then processed by wet film, iodine preparation and an enzyme-linked immunosorbent assay (ELISA kit to determine the presence of Giardia trophozoites and cysts. Statistical analysis was performed by sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy. Results and Conclusion: Of the 360 cases, 17.2% samples were positive for Giardia by direct microscopy and 23.6% were found to be positive by ELISA (sensitivity ~97%, but specificity was ~92% only. Because of less specificity, we need to perform ELISA in congruence with direct microscopy, etc. Further studies need to be performed on a larger sample size using other molecular tests in order to get more accurate estimations.

  9. Procedures for sampling and sample reduction within quality assurance systems for solid biofuels

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    The objective of this experimental study on sampling was to determine the size and number of samples of biofuels required (taken at two sampling points in each case) and to compare two methods of sampling. The first objective of the sample-reduction exercise was to compare the reliability of various sampling methods, and the second objective was to measure the variations introduced as a result of reducing the sample size to form suitable test portions. The materials studied were sawdust, wood chips, wood pellets and bales of straw, and these were analysed for moisture, ash, particle size and chloride. The sampling procedures are described. The study was conducted in Scandinavia. The results of the study were presented in Leipzig in October 2004. The work was carried out as part of the UK's DTI Technology Programme: New and Renewable Energy.

  10. Perceived social environment and adolescents' well-being and adjustment: Comparing a foster care sample with a matched sample

    OpenAIRE

    Farruggia, SP; Greenberger, E; Chen, C; Heckhausen, J

    2006-01-01

    Previous research has demonstrated that former foster care youth are at risk for poor outcomes (e.g., more problem behaviors, more depression, lower self-esteem, and poor social relationships). It is not clear, however, whether these findings reflect preemancipation developmental deficits. This study used 163 preemancipation foster care youth and a matched sample of 163 comparison youth. Results showed that foster-care youth did not differ from the comparison sample on measures of well-being,...

  11. Men who have sex with men in Great Britain: comparing methods and estimates from probability and convenience sample surveys

    Science.gov (United States)

    Prah, Philip; Hickson, Ford; Bonell, Chris; McDaid, Lisa M; Johnson, Anne M; Wayal, Sonali; Clifton, Soazig; Sonnenberg, Pam; Nardone, Anthony; Erens, Bob; Copas, Andrew J; Riddell, Julie; Weatherburn, Peter; Mercer, Catherine H

    2016-01-01

    Objective To examine sociodemographic and behavioural differences between men who have sex with men (MSM) participating in recent UK convenience surveys and a national probability sample survey. Methods We compared 148 MSM aged 18–64 years interviewed for Britain's third National Survey of Sexual Attitudes and Lifestyles (Natsal-3) undertaken in 2010–2012, with men in the same age range participating in contemporaneous convenience surveys of MSM: 15 500 British resident men in the European MSM Internet Survey (EMIS); 797 in the London Gay Men's Sexual Health Survey; and 1234 in Scotland's Gay Men's Sexual Health Survey. Analyses compared men reporting at least one male sexual partner (past year) on similarly worded questions and multivariable analyses accounted for sociodemographic differences between the surveys. Results MSM in convenience surveys were younger and better educated than MSM in Natsal-3, and a larger proportion identified as gay (85%–95% vs 62%). Partner numbers were higher and same-sex anal sex more common in convenience surveys. Unprotected anal intercourse was more commonly reported in EMIS. Compared with Natsal-3, MSM in convenience surveys were more likely to report gonorrhoea diagnoses and HIV testing (both past year). Differences between the samples were reduced when restricting analysis to gay-identifying MSM. Conclusions National probability surveys better reflect the population of MSM but are limited by their smaller samples of MSM. Convenience surveys recruit larger samples of MSM but tend to over-represent MSM identifying as gay and reporting more sexual risk behaviours. Because both sampling strategies have strengths and weaknesses, methods are needed to triangulate data from probability and convenience surveys. PMID:26965869

  12. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    Directory of Open Access Journals (Sweden)

    Pedro Fernández-Soto

    Full Text Available BACKGROUND: Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. METHODOLOGY/PRINCIPAL FINDINGS: We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. CONCLUSIONS/SIGNIFICANCE: Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA

  13. Gamma ray spectrometry results from core samples collected for RESUME 95

    International Nuclear Information System (INIS)

    Sanderson, D.C.W.; Allyson, J.D.; Toivonen, H.; Honkamaa, T.

    1997-01-01

    Field sampling of an airfield at Vesivehmaa, near Vaeaeksy, Finland (Area I) was carried out between 26-29 May 1995, to establish the radionuclide deposition and inventory of Chernobyl derived 137 Cs, and natural radionuclides. The objective was to establish a common calibration site for in-situ and airborne gamma spectrometers, for Exercise RESUME 95 conducted in August 1995. The report presents the sampling details, handling and treatment. The analyses are discussed with particular emphasis given to 137 Ca, 134 Cs, 40 K, 214 Bi and 208 radionuclides, and the quantification of their respective deposition and inventories. The results have been used to estimate the effective concentrations of nuclides at the calibration site for in-situ and airborne gamma spectrometry, and the depth distribution. For 137 Cs the weighted mean activity per unit area takes on values of 50.7±5.2 kBq m -2 at 1 m ground clearance, 51.1±6.9 kBq m -2 at 50 m height and 47.9±8.5 kBq m -2 at 100 m. The similarity of these values confirms the suitability of the Vesivehmaa site for comparison of in-situ and airborne results despite variations of a factor of two between results from individual cores. The mean α/ρ value for 137 Cs in Area I is 0.77±0.10 cm 2 g -1 (relaxation mass per unit area, β 1.31±0.15 gcm -2 ). Additional soil sampling across parts of Area II (a 6x3 km area selected for mapping Chernobyl deposition) was carried out. The mean level of 137 Cs activity from these samples was 92.4±63 kBq m -2 , a sample taken near Laihansuo showing the largest value obtained at 172 kBq m -2 . (EG)

  14. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    International Nuclear Information System (INIS)

    Barnett, J.M.; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-01-01

    Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor(reg s ign) 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R 2 ) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify

  15. Comparing distribution models for small samples of overdispersed counts of freshwater fish

    Science.gov (United States)

    Vaudor, Lise; Lamouroux, Nicolas; Olivier, Jean-Michel

    2011-05-01

    The study of species abundance often relies on repeated abundance counts whose number is limited by logistic or financial constraints. The distribution of abundance counts is generally right-skewed (i.e. with many zeros and few high values) and needs to be modelled for statistical inference. We used an extensive dataset involving about 100,000 fish individuals of 12 freshwater fish species collected in electrofishing points (7 m 2) during 350 field surveys made in 25 stream sites, in order to compare the performance and the generality of four distribution models of counts (Poisson, negative binomial and their zero-inflated counterparts). The negative binomial distribution was the best model (Bayesian Information Criterion) for 58% of the samples (species-survey combinations) and was suitable for a variety of life histories, habitat, and sample characteristics. The performance of the models was closely related to samples' statistics such as total abundance and variance. Finally, we illustrated the consequences of a distribution assumption by calculating confidence intervals around the mean abundance, either based on the most suitable distribution assumption or on an asymptotical, distribution-free (Student's) method. Student's method generally corresponded to narrower confidence intervals, especially when there were few (≤3) non-null counts in the samples.

  16. Are We Underestimating Benthic Cyanotoxins? Extensive Sampling Results from Spain

    Directory of Open Access Journals (Sweden)

    Enrique A. Cantoral Uriza

    2017-11-01

    Full Text Available Microcystins (MCs are potent hepatotoxins, and their presence in water bodies poses a threat to wildlife and human populations. Most of the available information refers to plankton, and much less is known about microcystins in other habitats. To broaden our understanding of the presence and environmental distribution of this group of toxins, we conducted extensive sampling throughout Spain, under a range of conditions and in distinct aquatic and terrestrial habitats. More than half of the tested strains were toxic; concentrations of the hepatotoxin were low compared with planktic communities, and the number of toxic variants identified in each sample of the Spanish strains ranged from 1–3. The presence of microcystins LF and LY (MC-LF and MC-LY in the tested samples was significant, and ranged from 21.4% to 100% of the total microcystins per strain. These strains were only detected in cyanobacteria Oscillatoriales and Nostocales. We can report, for the first time, seven new species of microcystin producers in high mountain rivers and chasmoendolithic communities. This is the first report of these species in Geitlerinema and the confirmation of Anatoxin-a in Phormidium uncinatum. Our findings show that microcystins are widespread in all habitat types, including both aerophytic and endolithic peat bogs and that it is necessary to identify all the variants of microcystins in aquatic bodies as the commonest toxins sometimes represent a very low proportion of the total.

  17. Are We Underestimating Benthic Cyanotoxins? Extensive Sampling Results from Spain.

    Science.gov (United States)

    Cantoral Uriza, Enrique A; Asencio, Antonia D; Aboal, Marina

    2017-11-28

    Microcystins (MCs) are potent hepatotoxins, and their presence in water bodies poses a threat to wildlife and human populations. Most of the available information refers to plankton, and much less is known about microcystins in other habitats. To broaden our understanding of the presence and environmental distribution of this group of toxins, we conducted extensive sampling throughout Spain, under a range of conditions and in distinct aquatic and terrestrial habitats. More than half of the tested strains were toxic; concentrations of the hepatotoxin were low compared with planktic communities, and the number of toxic variants identified in each sample of the Spanish strains ranged from 1-3. The presence of microcystins LF and LY (MC-LF and MC-LY) in the tested samples was significant, and ranged from 21.4% to 100% of the total microcystins per strain. These strains were only detected in cyanobacteria Oscillatoriales and Nostocales. We can report, for the first time, seven new species of microcystin producers in high mountain rivers and chasmoendolithic communities. This is the first report of these species in Geitlerinema and the confirmation of Anatoxin-a in Phormidium uncinatum . Our findings show that microcystins are widespread in all habitat types, including both aerophytic and endolithic peat bogs and that it is necessary to identify all the variants of microcystins in aquatic bodies as the commonest toxins sometimes represent a very low proportion of the total.

  18. Summary of Test Results for Daya Bay Rock Samples

    International Nuclear Information System (INIS)

    Onishi, Celia Tiemi; Dobson, Patrick; Nakagawa, Seiji

    2004-01-01

    A series of analytical tests was conducted on a suite of granitic rock samples from the Daya Bay region of southeast China. The objective of these analyses was to determine key rock properties that would affect the suitability of this location for the siting of a neutrino oscillation experiment. This report contains the results of chemical analyses, rock property measurements, and a calculation of the mean atomic weight

  19. EPICOR-II resin degradation results from first resin samples of PF-8 and PF-20

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Sanders, R.D. Sr.

    1985-12-01

    The 28 March 1979 accident at Three Mile Island Unit 2 released approximately 560,000 gallons of contaminated water to the Auxiliary and Fuel Handling Buildings. The water was decontaminated using a demineralization system called EPICOR-II developed by Epicor, Inc. The Low-Level Waste Data Base Development - EPICOR-II Resin/Liner Investigation Project is studying the chemical and physical conditions of the synthetic ion exchange resins found in several EPICOR-II prefilters. This report summarizes results and analyses of the first sampling of ion exchange resins from EPICOR-II prefilters PE-8 and -20. Results are compared with baseline data from tests performed on unirradiated Epicor, Inc. resins to determine if degradation has occurred due to the high internal radiation dose received by the EPICOR-II resins. Results also are compared with recent findings on resin degradation by Battelle Columbus Laboratories and Brookhaven National Laboratory. Analyses comparing test results of resins from EPICOR-II prefilters PF-8 and -20 with unirradiated resins obtained from Epicor, Inc. show resin degradation has occurred in some of the EPICOR-II resins examined. The mechanism of degradation is compared with work of other researchers and is consistent with their findings. The strong acid cation resins (divinylbenzene, styrene base structure) are losing effective cross-linking along with scission of functional groups and are experiencing first an increase and eventually a decrease in total exchange capacity as the absorbed radiation dose increases. The phenolic cation resins (phenol-formaldehyde base structure) show a loss of effective cross-linking and oxidation of the polymer chain. Analyses of resins removed from EPICOR-II prefilters PF-8 and -20 over the next several years should show a further increase in degradation

  20. Sample preparation for the HAW project and experimental results from the HFR

    International Nuclear Information System (INIS)

    Garcia Celma, A.; Wees, H. van; Miralles, L.

    1990-09-01

    This report deals with the preparation and analysis of samples, during the period May 1989-November 1989, for the High-Active Waste (HAW) project, a large-scale in situ test being performed underground in the Asse salt mine, Remlingen FRG. The development of the technical procedures required, and the scientific results, which regard mostly characterization of Potasas del Llobregat sample, are reported. Prior to using the samples in both the H.A.W. and the H.F.R. experiments they have to be machined to fit their holders. Technical improvements for machining samples of salt are reported. (H.W.). 9 refs.; 68 figs.; 10 tabs

  1. Gamma ray spectrometry results from core samples collected for RESUME 95

    Energy Technology Data Exchange (ETDEWEB)

    Sanderson, D.C.W.; Allyson, J.D. [SURRC, East Kilbride, Scotland (United Kingdom); Toivonen, H.; Honkamaa, T. [STUK, Helsinki (Finland)

    1997-12-31

    Field sampling of an airfield at Vesivehmaa, near Vaeaeksy, Finland (Area I) was carried out between 26-29 May 1995, to establish the radionuclide deposition and inventory of Chernobyl derived {sup 137}Cs, and natural radionuclides. The objective was to establish a common calibration site for in-situ and airborne gamma spectrometers, for Exercise RESUME 95 conducted in August 1995. The report presents the sampling details, handling and treatment. The analyses are discussed with particular emphasis given to {sup 137}Ca, {sup 134}Cs, {sup 40}K, {sup 214}Bi and {sup 208} radionuclides, and the quantification of their respective deposition and inventories. The results have been used to estimate the effective concentrations of nuclides at the calibration site for in-situ and airborne gamma spectrometry, and the depth distribution. For {sup 137}Cs the weighted mean activity per unit area takes on values of 50.7{+-}5.2 kBq m{sup -2} at 1 m ground clearance, 51.1{+-}6.9 kBq m{sup -2} at 50 m height and 47.9{+-}8.5 kBq m{sup -2} at 100 m. The similarity of these values confirms the suitability of the Vesivehmaa site for comparison of in-situ and airborne results despite variations of a factor of two between results from individual cores. The mean {alpha}/{rho} value for {sup 137}Cs in Area I is 0.77{+-}0.10 cm{sup 2}g{sup -1} (relaxation mass per unit area, {beta} 1.31{+-}0.15 gcm{sup -2}). Additional soil sampling across parts of Area II (a 6x3 km area selected for mapping Chernobyl deposition) was carried out. The mean level of {sup 137}Cs activity from these samples was 92.4{+-}63 kBq m{sup -2}, a sample taken near Laihansuo showing the largest value obtained at 172 kBq m{sup -2}. (EG). 17 refs.

  2. Gamma ray spectrometry results from core samples collected for RESUME 95

    Energy Technology Data Exchange (ETDEWEB)

    Sanderson, D C.W.; Allyson, J D [SURRC, East Kilbride, Scotland (United Kingdom); Toivonen, H; Honkamaa, T [STUK, Helsinki (Finland)

    1998-12-31

    Field sampling of an airfield at Vesivehmaa, near Vaeaeksy, Finland (Area I) was carried out between 26-29 May 1995, to establish the radionuclide deposition and inventory of Chernobyl derived {sup 137}Cs, and natural radionuclides. The objective was to establish a common calibration site for in-situ and airborne gamma spectrometers, for Exercise RESUME 95 conducted in August 1995. The report presents the sampling details, handling and treatment. The analyses are discussed with particular emphasis given to {sup 137}Ca, {sup 134}Cs, {sup 40}K, {sup 214}Bi and {sup 208} radionuclides, and the quantification of their respective deposition and inventories. The results have been used to estimate the effective concentrations of nuclides at the calibration site for in-situ and airborne gamma spectrometry, and the depth distribution. For {sup 137}Cs the weighted mean activity per unit area takes on values of 50.7{+-}5.2 kBq m{sup -2} at 1 m ground clearance, 51.1{+-}6.9 kBq m{sup -2} at 50 m height and 47.9{+-}8.5 kBq m{sup -2} at 100 m. The similarity of these values confirms the suitability of the Vesivehmaa site for comparison of in-situ and airborne results despite variations of a factor of two between results from individual cores. The mean {alpha}/{rho} value for {sup 137}Cs in Area I is 0.77{+-}0.10 cm{sup 2}g{sup -1} (relaxation mass per unit area, {beta} 1.31{+-}0.15 gcm{sup -2}). Additional soil sampling across parts of Area II (a 6x3 km area selected for mapping Chernobyl deposition) was carried out. The mean level of {sup 137}Cs activity from these samples was 92.4{+-}63 kBq m{sup -2}, a sample taken near Laihansuo showing the largest value obtained at 172 kBq m{sup -2}. (EG). 17 refs.

  3. Comparing adults who use cannabis medically with those who use recreationally: Results from a national sample.

    Science.gov (United States)

    Lin, Lewei A; Ilgen, Mark A; Jannausch, Mary; Bohnert, Kipling M

    2016-10-01

    Cannabis has been legalized for medical use in almost half of the states in the U.S. Although laws in these states make the distinction between medical and recreational use of cannabis, the prevalence of people using medical cannabis and how distinct this group is from individuals using cannabis recreationally is unknown at a national level. Data came from the 2013 National Survey on Drug Use and Health (NSDUH). All adults endorsing past year cannabis use who reported living in a state that had legalized medical cannabis were divided into recreational cannabis use only and medical cannabis use. Demographic and clinical characteristics were compared across these two groups. 17% of adults who used cannabis in the past year used cannabis medically. There were no significant differences between those who used medically versus recreationally in race, education, past year depression and prevalence of cannabis use disorders. In adjusted analyses, those with medical cannabis use were more likely to have poorer health and lower levels of alcohol use disorders and non-cannabis drug use. A third of those who reported medical cannabis use endorsed daily cannabis use compared to 11% in those who reported recreational use exclusively. Adults who use medical and recreational cannabis shared some characteristics, but those who used medical cannabis had higher prevalence of poor health and daily cannabis use. As more states legalize cannabis for medical use, it is important to better understand similarities and differences between people who use cannabis medically and recreationally. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Comparative study of methods on outlying data detection in experimental results

    International Nuclear Information System (INIS)

    Oliveira, P.M.S.; Munita, C.S.; Hazenfratz, R.

    2009-01-01

    The interpretation of experimental results through multivariate statistical methods might reveal the outliers existence, which is rarely taken into account by the analysts. However, their presence can influence the results interpretation, generating false conclusions. This paper shows the importance of the outliers determination for one data base of 89 samples of ceramic fragments, analyzed by neutron activation analysis. The results were submitted to five procedures to detect outliers: Mahalanobis distance, cluster analysis, principal component analysis, factor analysis, and standardized residual. The results showed that although cluster analysis is one of the procedures most used to identify outliers, it can fail by not showing the samples that are easily identified as outliers by other methods. In general, the statistical procedures for the identification of the outliers are little known by the analysts. (author)

  5. Comparative growth models of big-scale sand smelt (Atherina boyeri Risso, 1810 sampled from Hirfanll Dam Lake, Klrsehir, Ankara, Turkey

    Directory of Open Access Journals (Sweden)

    S. Benzer

    2017-06-01

    Full Text Available In this current publication the growth characteristics of big-scale sand smelt data were compared for population dynamics within artificial neural networks and length-weight relationships models. This study aims to describe the optimal decision of the growth model of big-scale sand smelt by artificial neural networks and length-weight relationships models at Hirfanll Dam Lake, Klrsehir, Turkey. There were a total of 1449 samples collected from Hirfanll Dam Lake between May 2015 and May 2016. Both model results were compared with each other and the results were also evaluated with MAPE (mean absolute percentage error, MSE (mean squared error and r2 (coefficient correlation data as a performance criterion. The results of the current study show that artificial neural networks is a superior estimation tool compared to length-weight relationships models of big-scale sand smelt in Hirfanll Dam Lake.

  6. Results For The Third Quarter 2010 Tank 50 WAC Slurry Sample: Chemical And Radionuclide Contaminant Results

    International Nuclear Information System (INIS)

    Reigel, M.; Bibler, N.

    2010-01-01

    This report details the chemical and radionuclide contaminant results for the characterization of the 2010 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (i) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (ii) The reported detection limits for 94 Nb, 247 Cm and 249 Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 3. (iii) The reported detection limit for 242m Am is greater than the requested limit from Attachment 8.4 of the WAC. (iv) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (v) The reported concentration of Isopropanol is greater than the limit from Table 4 of the WAC. (vi) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

  7. Rheology and TIC/TOC results of ORNL tank samples

    International Nuclear Information System (INIS)

    Pareizs, J. M.; Hansen, E. K.

    2013-01-01

    The Savannah River National Laboratory (SRNL)) was requested by Oak Ridge National Laboratory (ORNL) to perform total inorganic carbon (TIC), total organic carbon (TOC), and rheological measurements for several Oak Ridge tank samples. As received slurry samples were diluted and submitted to SRNL-Analytical for TIC and TOC analyses. Settled solids yield stress (also known as settled shear strength) of the as received settled sludge samples were determined using the vane method and these measurements were obtained 24 hours after the samples were allowed to settled undisturbed. Rheological or flow properties (Bingham Plastic viscosity and Bingham Plastic yield stress) were determined from flow curves of the homogenized or well mixed samples. Other targeted total suspended solids (TSS) concentrations samples were also analyzed for flow properties and these samples were obtained by diluting the as-received sample with de-ionized (DI) water

  8. Assessing the validity of single-item life satisfaction measures: results from three large samples.

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E

    2014-12-01

    The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS)-a more psychometrically established measure. Two large samples from Washington (N = 13,064) and Oregon (N = 2,277) recruited by the Behavioral Risk Factor Surveillance System and a representative German sample (N = 1,312) recruited by the Germany Socio-Economic Panel were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62-0.64; disattenuated r = 0.78-0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001-0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS was very small (average absolute difference = 0.015-0.042). Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use.

  9. Sample Results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H Qualification Samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Washington, A. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-01-01

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub- Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D(Cs)) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

  10. Sample results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H qualification samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Washington, II, A. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-01-13

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub-Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D(Cs)) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

  11. Tank vapor characterization project - headspace vapor characterization of Hanford Waste Tank 241-C-107: Second comparison study results from samples collected on 3/26/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-C-107 (Tank C-107) at the Hanford Site in Washington State. The results described in this report is the second in a series comparing vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H 2 O) and ammonia (NH 3 ), permanent gases, total non-methane organic compounds (TO-12), and individual organic analytes collected in SUMMA trademark canisters and on triple sorbent traps (TSTs). Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC

  12. Tank vapor characterization project. Headspace vapor characterization of Hanford waste tank 241-BY-108: Second comparison study results from samples collected on 3/28/96

    International Nuclear Information System (INIS)

    Thomas, B.L.; Pool, K.H.; Evans, J.C.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-BY-108 (Tank BY-108) at the Hanford Site in Washington State. The results described in this report is the second in a series comparing vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H 2 O) and ammonia (NH 3 ), permanent gases, total non-methane organic compounds (TO-12), and individual organic analytes collected in SUMMA trademark canisters and on triple sorbent traps (TSTs). Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC

  13. [Confirming Indicators of Qualitative Results by Chromatography-mass Spectrometry in Biological Samples].

    Science.gov (United States)

    Liu, S D; Zhang, D M; Zhang, W; Zhang, W F

    2017-04-01

    Because of the exist of complex matrix, the confirming indicators of qualitative results for toxic substances in biological samples by chromatography-mass spectrometry are different from that in non-biological samples. Even in biological samples, the confirming indicators are different in various application areas. This paper reviews the similarities and differences of confirming indicators for the analyte in biological samples by chromatography-mass spectrometry in the field of forensic toxicological analysis and other application areas. These confirming indicators include retention time (RT), relative retention time (RRT), signal to noise (S/N), characteristic ions, relative abundance of characteristic ions, parent ion-daughter ion pair and abundance ratio of ion pair, etc. Copyright© by the Editorial Department of Journal of Forensic Medicine.

  14. Studies on the comparability of the results from different methods for the radioimmunological determination of digoxin

    International Nuclear Information System (INIS)

    Dwenger, A.; Trautschold, I.

    1978-01-01

    Three iodine-125-digoxin radioimmunoassay kits (A Amersham Buchler; B Boehringer Mannheim; C Schwarz Mann/Becton Dickinson) were evaluated with respect to assay quality and comparability of the results. Intra- and interassay variances were calculated for the following types of samples: Three media (a pool serum; b artificial human serum; c buffer solution with albumin and globulin) containing pure digoxin, sera from a pharmacokinetic study, sera with different concentrations of proteins, a hemolytic serum and sera with digitoxin and metabolites of spironolactone. The intra-assay precision depended on the medium of the sample and was higher for samples with identical digoxin concentrations in an identical medium (e.g. CV for 2 μg/l in medium a for kit A: 4.3% for kit B: 7.0%; for kit C: 2.2%) than for samples with identical antigen concentrations in different media (CV for 2 μg/l in media a, b and c for kit A: 6.4%; for kit B: 9.1%; for kit C: 4.3%). The mean recovery in the range 0.5-4 μg/l depended on the kind of medium (a, b or c) and varied for kit A from 84.4% to 100.8%, for kit B from 112.0% to 119.6%, and for kit C from 98.0% to 104.5%. Decreasing serum protein concentrations to less than one half of the physiological concentration gave false negative results for kit A and fals positive results for kit C; for kit B this dependency was not be observed, but there was a decrease of reproducibility. (orig./AJ) [de

  15. Comparing Simulated and Theoretical Sampling Distributions of the U3 Person-Fit Statistic.

    Science.gov (United States)

    Emons, Wilco H. M.; Meijer, Rob R.; Sijtsma, Klaas

    2002-01-01

    Studied whether the theoretical sampling distribution of the U3 person-fit statistic is in agreement with the simulated sampling distribution under different item response theory models and varying item and test characteristics. Simulation results suggest that the use of standard normal deviates for the standardized version of the U3 statistic may…

  16. A Comparison of RNA-Seq Results from Paired Formalin-Fixed Paraffin-Embedded and Fresh-Frozen Glioblastoma Tissue Samples.

    Directory of Open Access Journals (Sweden)

    Anna Esteve-Codina

    Full Text Available The molecular classification of glioblastoma (GBM based on gene expression might better explain outcome and response to treatment than clinical factors. Whole transcriptome sequencing using next-generation sequencing platforms is rapidly becoming accepted as a tool for measuring gene expression for both research and clinical use. Fresh frozen (FF tissue specimens of GBM are difficult to obtain since tumor tissue obtained at surgery is often scarce and necrotic and diagnosis is prioritized over freezing. After diagnosis, leftover tissue is usually stored as formalin-fixed paraffin-embedded (FFPE tissue. However, RNA from FFPE tissues is usually degraded, which could hamper gene expression analysis. We compared RNA-Seq data obtained from matched pairs of FF and FFPE GBM specimens. Only three FFPE out of eleven FFPE-FF matched samples yielded informative results. Several quality-control measurements showed that RNA from FFPE samples was highly degraded but maintained transcriptomic similarities to RNA from FF samples. Certain issues regarding mutation analysis and subtype prediction were detected. Nevertheless, our results suggest that RNA-Seq of FFPE GBM specimens provides reliable gene expression data that can be used in molecular studies of GBM if the RNA is sufficiently preserved.

  17. Effect of order of draw of blood samples during phlebotomy on routine biochemistry results.

    Science.gov (United States)

    Sulaiman, Raashda A; Cornes, Michael P; Whitehead, Simon J; Othonos, Nadia; Ford, Clare; Gama, Rousseau

    2011-11-01

    To investigate whether incorrect order of draw of blood samples during phlebotomy causes in vitro potassium ethylenediaminetetraacetic acid EDTA (kEDTA) contamination of blood samples. Serum kEDTA, potassium, calcium, magnesium, alkaline phosphatase, zinc and iron concentrations were measured in blood samples drawn before and after collecting blood into kEDTA containing sample tubes by an experienced phlebotomist using the Sarstedt Safety Monovette system. EDTA was undetectable in all samples. The concentrations of other analytes were similar in blood samples drawn before and after collection of the EDTA blood sample. Order of draw of blood samples using the Sarstedt Safety Monovette system has no effect on serum biochemistry results, when samples are taken by an experienced phlebotomist.

  18. Analytical results from salt batch 9 routine DSSHT and SEHT monthly samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-01

    Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 9 have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Cs removal continues to be acceptable, with decontamination factors (DF) averaging 25700 (107% RSD). The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior, other than lacking the anticipated degree of dilution that is calculated to occur during Modular Caustic-Side Solvent Extraction Unit (MCU) processing.

  19. Clean Sampling of an Englacial Conduit at Blood Falls, Antarctica - Some Experimental and Numerical Results

    Science.gov (United States)

    Kowalski, Julia; Francke, Gero; Feldmann, Marco; Espe, Clemens; Heinen, Dirk; Digel, Ilya; Clemens, Joachim; Schüller, Kai; Mikucki, Jill; Tulaczyk, Slawek M.; Pettit, Erin; Berry Lyons, W.; Dachwald, Bernd

    2017-04-01

    results of its deployment at Blood Falls. In contrast to conventional melting-probe applications, which can only melt vertically, the IceMole realized an oblique melting path to penetrate the englacial conduit. Experimental and numerical results on melting at oblique angles are rare. Besides reporting on the IceMole technology and the field deployment itself, we will compare and discuss the observed melting behavior with re-analysis results in the context of a recently developed numerical model. Finally, we will present our first steps in utilizing the model to infer on the ambient cryo-environment.

  20. Results of groundwater monitoring and vegetation sampling at Everest, Kansas, in 2009 .

    Energy Technology Data Exchange (ETDEWEB)

    LaFreniere, L. M.; Environmental Science Division

    2010-05-13

    In April 2008, the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) conducted groundwater sampling for the analysis of volatile organic compounds (VOCs) in the existing network of monitoring points at Everest, Kansas (Argonne 2008). The objective of the 2008 investigation was to monitor the distribution of carbon tetrachloride contamination in groundwater previously identified in CCC/USDA site characterization and groundwater sampling studies at Everest in 2000-2006 (Argonne 2001, 2003, 2006a,b). The work at Everest is being undertaken on behalf of the CCC/USDA by Argonne National Laboratory, under the oversight of the Kansas Department of Health and Environment (KDHE). The findings of the 2008 investigation were as follows: (1) Measurements of groundwater levels obtained manually and through the use of automatic recorders demonstrated a consistent pattern of groundwater flow - and inferred contaminant migration - to the north-northwest from the former CCC/USDA facility toward the Nigh property, and then west-southwest from the Nigh property toward the intermittent creek that lies west of the former CCC/USDA facility and the Nigh property. (2) The range of concentrations and the areal distribution of carbon tetrachloride identified in the groundwater at Everest in April 2008 were generally consistent with previous results. The results of the 2008 sampling (reflecting the period from 2006 to 2008) and the earlier investigations at Everest (representing the period from 2000 to 2006) show that no significant downgradient extension of the carbon tetrachloride plume occurred from 2000 to 2008. (3) The slow contaminant migration indicated by the monitoring data is qualitatively consistent with the low groundwater flow rates in the Everest aquifer unit estimated previously on the basis of site-specific hydraulic testing (Argonne 2006a,b). (4) The April 2008 and earlier sampling results demonstrate that the limits of the plume have been

  1. Comparative Performance of PLZT and PVDF Pyroelectric Sensors Used to the Thermal Characterization of Liquid Samples

    Directory of Open Access Journals (Sweden)

    Gemima Lara Hernandez

    2013-01-01

    Full Text Available Among the photothermal methods, the photopyroelectric (PPE technique is a suitable method to determine thermal properties of different kinds of samples ranging from solids to liquids and gases. Polyvinylidene difluoride (PVDF is one of the most frequently used pyroelectric sensors in PPE technique but has the disadvantage that it can be easily deformed by the sample weight. This deformation could add a piezoelectric effect to the thermal parameters assessment; also PVDF has a narrow temperature operation range when compared with ceramic pyroelectric sensors. In order to minimize possible piezoelectric effects due to sensor deformation, a ceramic of lanthanum modified lead zirconate (PLZT was used as pyroelectric sensor in the PPE technique. Then, thermal diffusivity of some liquid samples was measured, by using the PPE configuration that denominated the thermal wave resonator cavity (TWRC, with a PLZT ceramic as pyroelectric detector. The performance obtained with the proposed ceramic in the TWRC configuration was compared with that obtained with PVDF by using the same configuration.

  2. Using DNA Barcoding and Standardized Sampling to Compare Geographic and Habitat Differentiation of Crustaceans: A Hawaiian Islands Example

    Directory of Open Access Journals (Sweden)

    M. Julian Caley

    2011-09-01

    Full Text Available Recently, the Census of Marine Life has explored methods to assess coral reef diversity by combining standardized sampling (to permit comparison across sites with molecular techniques (to make rapid counts of species possible. To date, this approach has been applied across geographically broad scales (seven sites spanning the Indian, Pacific and Atlantic Oceans, focusing on similar habitats at all sites (10–12 m forereef. Here we examine crustacean spatial diversity patterns for a single atoll, comparing results for four sites (comprising forereef, backreef, and lagoon habitats at French Frigate Shoals (FFS, Northwestern Hawaiian Islands, Hawaii, USA, within the Papahanaumokuakea Marine National Monument. The Bray-Curtis index of similarity across these habitats at FFS was the same or greater than the similarity between similar habitats on Heron Island and Lizard Island in the Great Barrier Reef and much greater than similarity between more widely separated localities in the Indo-Pacific Ocean (e.g., Ningaloo, Moorea, French Polynesia or the Line Islands. These results imply that, at least for shallow reefs, sampling multiple locations versus sampling multiple habitats within a site maximizes the rate at which we can converge on the best global estimate of coral reef biodiversity.

  3. Choosing a suitable sample size in descriptive sampling

    International Nuclear Information System (INIS)

    Lee, Yong Kyun; Choi, Dong Hoon; Cha, Kyung Joon

    2010-01-01

    Descriptive sampling (DS) is an alternative to crude Monte Carlo sampling (CMCS) in finding solutions to structural reliability problems. It is known to be an effective sampling method in approximating the distribution of a random variable because it uses the deterministic selection of sample values and their random permutation,. However, because this method is difficult to apply to complex simulations, the sample size is occasionally determined without thorough consideration. Input sample variability may cause the sample size to change between runs, leading to poor simulation results. This paper proposes a numerical method for choosing a suitable sample size for use in DS. Using this method, one can estimate a more accurate probability of failure in a reliability problem while running a minimal number of simulations. The method is then applied to several examples and compared with CMCS and conventional DS to validate its usefulness and efficiency

  4. Preterm Cord Blood Contains a Higher Proportion of Immature Hematopoietic Progenitors Compared to Term Samples.

    Science.gov (United States)

    Podestà, Marina; Bruschettini, Matteo; Cossu, Claudia; Sabatini, Federica; Dagnino, Monica; Romantsik, Olga; Spaggiari, Grazia Maria; Ramenghi, Luca Antonio; Frassoni, Francesco

    2015-01-01

    Cord blood contains high number of hematopoietic cells that after birth disappear. In this paper we have studied the functional properties of the umbilical cord blood progenitor cells collected from term and preterm neonates to establish whether quantitative and/or qualitative differences exist between the two groups. Our results indicate that the percentage of total CD34+ cells was significantly higher in preterm infants compared to full term: 0.61% (range 0.15-4.8) vs 0.3% (0.032-2.23) p = 0.0001 and in neonates <32 weeks of gestational age (GA) compared to those ≥32 wks GA: 0.95% (range 0.18-4.8) and 0.36% (0.15-3.2) respectively p = 0.0025. The majority of CD34+ cells co-expressed CD71 antigen (p<0.05 preterm vs term) and grew in vitro large BFU-E, mostly in the second generation. The subpopulations CD34+CD38- and CD34+CD45- resulted more represented in preterm samples compared to term, conversely, Side Population (SP) did not show any difference between the two group. The absolute number of preterm colonies (CFCs/10microL) resulted higher compared to term (p = 0.004) and these progenitors were able to grow until the third generation maintaining an higher proportion of CD34+ cells (p = 0.0017). The number of colony also inversely correlated with the gestational age (Pearson r = -0.3001 p<0.0168). We found no differences in the isolation and expansion capacity of Endothelial Colony Forming Cells (ECFCs) from cord blood of term and preterm neonates: both groups grew in vitro large number of endothelial cells until the third generation and showed a transitional phenotype between mesenchymal stem cells and endothelial progenitors (CD73, CD31, CD34 and CD144)The presence, in the cord blood of preterm babies, of high number of immature hematopoietic progenitors and endothelial/mesenchymal stem cells with high proliferative potential makes this tissue an important source of cells for developing new cells therapies.

  5. Preterm Cord Blood Contains a Higher Proportion of Immature Hematopoietic Progenitors Compared to Term Samples.

    Directory of Open Access Journals (Sweden)

    Marina Podestà

    Full Text Available Cord blood contains high number of hematopoietic cells that after birth disappear. In this paper we have studied the functional properties of the umbilical cord blood progenitor cells collected from term and preterm neonates to establish whether quantitative and/or qualitative differences exist between the two groups.Our results indicate that the percentage of total CD34+ cells was significantly higher in preterm infants compared to full term: 0.61% (range 0.15-4.8 vs 0.3% (0.032-2.23 p = 0.0001 and in neonates <32 weeks of gestational age (GA compared to those ≥32 wks GA: 0.95% (range 0.18-4.8 and 0.36% (0.15-3.2 respectively p = 0.0025. The majority of CD34+ cells co-expressed CD71 antigen (p<0.05 preterm vs term and grew in vitro large BFU-E, mostly in the second generation. The subpopulations CD34+CD38- and CD34+CD45- resulted more represented in preterm samples compared to term, conversely, Side Population (SP did not show any difference between the two group. The absolute number of preterm colonies (CFCs/10microL resulted higher compared to term (p = 0.004 and these progenitors were able to grow until the third generation maintaining an higher proportion of CD34+ cells (p = 0.0017. The number of colony also inversely correlated with the gestational age (Pearson r = -0.3001 p<0.0168.We found no differences in the isolation and expansion capacity of Endothelial Colony Forming Cells (ECFCs from cord blood of term and preterm neonates: both groups grew in vitro large number of endothelial cells until the third generation and showed a transitional phenotype between mesenchymal stem cells and endothelial progenitors (CD73, CD31, CD34 and CD144The presence, in the cord blood of preterm babies, of high number of immature hematopoietic progenitors and endothelial/mesenchymal stem cells with high proliferative potential makes this tissue an important source of cells for developing new cells therapies.

  6. Gasbuggy, New Mexico, Hydrologic and Natural Gas Sampling and Analysis Results for 2009

    International Nuclear Information System (INIS)

    2009-11-01

    The U.S. Department of Energy (DOE) Office of Legacy Management conducted hydrologic and natural gas sampling for the Gasbuggy, New Mexico, site on June 16, and 17, 2009. Hydrologic sampling consists of collecting water samples from water wells and surface water locations. Natural gas sampling consists of collecting both gas samples and samples of produced water from gas production wells. The water well samples were analyzed for gamma-emitting radionuclides and tritium. Surface water samples were analyzed for tritium. Water samples from gas production wells were analyzed for gamma-emitting radionuclides, gross alpha, gross beta, and tritium. Natural gas samples were analyzed for tritium and carbon-14. Water samples were analyzed by ALS Laboratory Group in Fort Collins, Colorado, and natural gas samples were analyzed by Isotech Laboratories in Champaign, Illinois. Concentrations of tritium and gamma-emitting radionuclides in water samples collected in the vicinity of the Gasbuggy site continue to demonstrate that the sample locations have not been impacted by detonation-related contaminants. Results from the sampling of natural gas from producing wells demonstrate that the gas wells nearest the Gasbuggy site are not currently impacted by detonation-related contaminants. Annual sampling of the gas production wells nearest the Gasbuggy site for gas and produced water will continue for the foreseeable future. The sampling frequency of water wells and surface water sources in the surrounding area will be reduced to once every 5 years. The next hydrologic sampling event at water wells, springs, and ponds will be in 2014.

  7. Information Uncertainty to Compare Qualitative Reasoning Security Risk Assessment Results

    Energy Technology Data Exchange (ETDEWEB)

    Chavez, Gregory M [Los Alamos National Laboratory; Key, Brian P [Los Alamos National Laboratory; Zerkle, David K [Los Alamos National Laboratory; Shevitz, Daniel W [Los Alamos National Laboratory

    2009-01-01

    The security risk associated with malevolent acts such as those of terrorism are often void of the historical data required for a traditional PRA. Most information available to conduct security risk assessments for these malevolent acts is obtained from subject matter experts as subjective judgements. Qualitative reasoning approaches such as approximate reasoning and evidential reasoning are useful for modeling the predicted risk from information provided by subject matter experts. Absent from these approaches is a consistent means to compare the security risk assessment results. Associated with each predicted risk reasoning result is a quantifiable amount of information uncertainty which can be measured and used to compare the results. This paper explores using entropy measures to quantify the information uncertainty associated with conflict and non-specificity in the predicted reasoning results. The measured quantities of conflict and non-specificity can ultimately be used to compare qualitative reasoning results which are important in triage studies and ultimately resource allocation. Straight forward extensions of previous entropy measures are presented here to quantify the non-specificity and conflict associated with security risk assessment results obtained from qualitative reasoning models.

  8. Characterization of Tank 16H Annulus Samples Part II: Leaching Results

    International Nuclear Information System (INIS)

    Hay, M.; Reboul, S.

    2012-01-01

    The closure of Tank 16H will require removal of material from the annulus of the tank. Samples from Tank 16H annulus were characterized and tested to provide information to evaluate various alternatives for removing the annulus waste. The analysis found all four annulus samples to be composed mainly of Si, Na, and Al and lesser amounts of other elements. The XRD data indicate quartz (SiO 2 ) and sodium aluminum nitrate silicate hydrate (Na 8 (Al 6 Si 6 O 24 )(NO 3 ) 2 .4H 2 O) as the predominant crystalline mineral phases in the samples. The XRD data also indicate the presence of crystalline sodium nitrate (NaNO 3 ), sodium nitrite (NaNO 2 ), gibbsite (Al(OH) 3 ), hydrated sodium bicarbonate (Na 3 H(CO 3 ) 2 .2H 2 O), and muscovite (KAl 2 (AlSi 3 O 10 )(OH) 2 ). Based on the weight of solids remaining at the end of the test, the water leaching test results indicate 20-35% of the solids dissolved after three contacts with an approximately 3:1 volume of water at 45 C. The chemical analysis of the leachates and the XRD results of the remaining solids indicate sodium salts of nitrate, nitrite, sulfate, and possibly carbonate/bicarbonate make up the majority of the dissolved material. The majority of these salts were dissolved in the first water contact and simply diluted with each subsequent water contact. The water leaching removed large amounts of the uranium in two of the samples and approximately 1/3 of the 99 Tc from all four samples. Most of the other radionuclides analyzed showed low solubility in the water leaching test. The oxalic acid leaching test result indicate approximately 34-47% of the solids in the four annulus samples will dissolve after three contacts with an approximately 3:1 volume of acid to solids at 45 C. The same sodium salts found in the water leaching test comprise the majority of dissolved material in the oxalic acid leaching test. However, the oxalic acid was somewhat more effective in dissolving radionuclides than the water leach. In

  9. Measurement of fat in the ovine milk: comparative study of the results acquired by official methodology and by electr onic equipments

    Directory of Open Access Journals (Sweden)

    Luiz Gustavo de Pellegrini

    2016-06-01

    Full Text Available The aim of this work was to perform a comparative study between the official method recommended by Brazilian laws and the electronic equipment of photometric measurement and ultrasound spectroscopy equipment for the quantification of total lipids of the ovine milk in order to check which equipment establishes the lipids level better. The experiment took place at Technology of Food Department in Santa Maria Federal University together with School Plant of Dairy products and Ovine culture Section of Zoo Technical Department. It was used twelve sheeps half Lacaune Lait blood, milked individually from the first to the tenth week of lactation. The milking was performed manually and the analyses took place after the refrigeration of the samples. Before executing the analyses, the samples were homogenized and soon after evaluated in terms of fat amount by three distinct methodologies: official Brazilian methodology through Gerber’s butyrometer (GB, electronic equipment of photometric measurement Milko-Tester® (MT and ultrasound spectroscopic equipment Lactoscan 90® (LS, which all analyses were performed in triple. The reproducibility of LS equipment was 100% for the analyzed samples, while MT equipment showed variability in most of the analyzed samples obtaining reproducibility of the results in just 22,5% of the samples. For the others samples the latter equipment obtained 50% of overrated values and 27,5% underrated values. Therefore, the results of this study let us to settle that the analysis of ovine Milk by ultrasound spectroscopy is efficient for the fat parameter when compared to the official Brazilian methodology.

  10. Near-IR laser-based spectrophotometer for comparative analysis of isotope content of CO2 in exhale air samples

    International Nuclear Information System (INIS)

    Stepanov, E V; Glushko, A N; Kasoev, S G; Koval', A V; Lapshin, D A

    2011-01-01

    We present a laser spectrophotometer aimed at high-accuracy comparative analysis of content of 12 CO 2 and 13 CO 2 isotope modifications in the exhale air samples and based on a tunable near-IR diode laser (2.05 μm). The two-channel optical scheme of the spectrophotometer and the special digital system for its control are described. An algorithm of spectral data processing aimed at determining the difference in the isotope composition of gas mixtures is proposed. A few spectral regions (near 4880 cm -1 ) are determined to be optimal for analysis of relative content of 12 CO 2 and 13 CO 2 in the exhale air. The use of the proposed spectrophotometer scheme and the developed algorithm makes the results of the analysis less susceptible to the influence of the interference in optical elements, to the absorption in the open atmosphere, to the slow drift of the laser pulse envelope, and to the offset of optical channels. The sensitivity of the comparative analysis of the isotope content of CO 2 in exhale air samples, achieved using the proposed scheme, is estimated to be nearly 0.1‰.

  11. PIXE analysis of thin samples

    International Nuclear Information System (INIS)

    Kiss, Ildiko; Koltay, Ede; Szabo, Gyula; Laszlo, S.; Meszaros, A.

    1985-01-01

    Particle-induced X-ray emission (PIXE) multielemental analysis of thin film samples are reported. Calibration methods of K and L X-lines are discussed. Application of PIXE analysis to aerosol monitoring, multielement aerosol analysis is described. Results of PIXE analysis of samples from two locations in Hungary are compared with the results of aerosol samples from Scandinavia and the USA. (D.Gy.)

  12. Tank 241-C-111 headspace gas and vapor sample results - August 1993 samples

    International Nuclear Information System (INIS)

    Huckaby, J.L.

    1994-01-01

    Tank 241-C-111 is on the ferrocyanide Watch List. Gas and vapor samples were collected to assure safe conditions before planned intrusive work was performed. Sample analyses showed that hydrogen is about ten times higher in the tank headspace than in ambient air. Nitrous oxide is about sixty times higher than ambient levels. The hydrogen cyanide concentration was below 0.04 ppbv, and the average NO x concentration was 8.6 ppmv

  13. Scintigraphy and venous sampling in endocrine adrenal diseases. Clinical results in 85 patients

    International Nuclear Information System (INIS)

    Feltrin, G.P.; Maffessanti, M.; Miotto, D.; Mantero, F.; Macri, G.; Romani, S.

    1979-01-01

    The results obtained by adrenal scanning and venous sampling in 85 patients affected by various forms of adrenal pathology are reported and discussed. Pheochromocytoma rarely needs venous catheterization and blood sampling, since arteriography is almost always capable to visualize it. Scintigraphy alone is generally accurate enough to distinguish between bilateral hyperplasia and tumors in Cushing's and adrenogenital syndromes (100% of personal observations); only a tumoral situation benefits by venous catheterization. Blood samples and venography must be preceded by scintigraphy in Conn's syndrome

  14. Sampling of dissolved gases in deep groundwater pumped to the surface

    International Nuclear Information System (INIS)

    Lahdenperae, J.

    2006-08-01

    The aim of this study was to develop method for sampling dissolved gases in groundwater pumped out from borehole. In this report the developed method called Simple gas collector (YKK) and the first results gained are described. Samples were collected from five sampling sections. First test samplings were made from multipackered deep borehole (OL-KR1/523,2-528,2 m). The rest of samples were sampled during prepumping of PAVE-samplings. All samples were analysed with mass spectrometer. Gas composition results were very reproducible but gas concentration results varied in some sampling sections. Achieved results were compared with gas results of groundwater samples taken with PAVE-equipment. YKK-results were mainly comparable to PAVE-results, although differences were observed in both gas composition and concentration results. When gas concentration is small ( 2 O) gas compositions are very comparable and when concentration is high compositions differs between YKK- and PAVE-results. Gas concentration values were very comparable when the groundwater samples contained gases a lot, but the differences were relatively higher, when the gas amount in the groundwater sample was small. According to the survey you can get comparable information of dissolved gases in groundwater with YKK-method. The limit of using this method is that pumped groundwater must be oversaturated with gases in sampling conditions. (orig.)

  15. Comparing Profile of Temperament and Character Dimensions in Patients with Major Depressive Disorder and Bipolar Mood Disorder and Control Group in the Iranian Sample

    Directory of Open Access Journals (Sweden)

    shahram hajirezaei

    2017-06-01

    Full Text Available Objective: This study was conducted to compare the profile of Temperament and Character dimensions in patients with major depressive disorder and bipolar mood disorder and control group.Methods: In this causal-comparative study the population consisted of two clinical groups (major depressive disorder and bipolar mood disorder and a non-clinical group. The sample was 193 subjects (77 patients with major depressive disorder, 86 patients with bipolar mood disorder, and 30 normal people with an age range of 18-65 years and the mean age of 40.1. They were selected from Roozbeh psychiatric hospital using available sampling method. Tools used in this research included Temperament and Character Inventory-140 and General Health Questionnaire-28. Collected data were analyzed by statistical methods of independent t-test and one-way analysis of variance using Statistical Package for the Social Sciences-22 software.Result: The results of comparing the groups showed that there was a significant difference among groups in dimensions of Novelty Seeking, Harm Avoidance, Persistence, Self-Directedness and Cooperativeness (P <0.05. The results showed that only in the Novelty Seeking dimension, the mean was different in males and females (P <0.05.Conclusion: In general, our results showed that patients with major depressive disorder and bipolar mood disorder have different personality profile in some dimensions of Temperament and Character compared with control group.

  16. Solvent hold tank sample results for MCU-16-1363-1365. November 2016 monthly sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-03-22

    Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1363-1364-1365), pulled on 11/15/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1363-1364-1365 indicated the Isopar™L concentration is at its nominal level (100%). The extractant (MaxCalix) and the modifier (CS- 7SB) are 8% and 2 % below their nominal concentrations. The suppressor (TiDG) is 7% below its nominal concentration. This analysis confirms the trim and Isopar™ additions to the solvent in November. This analysis also indicates the solvent did not require further additions. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

  17. Examination of anonymous canine faecal samples provides data on endoparasite prevalence rates in dogs for comparative studies.

    Science.gov (United States)

    Hinney, Barbara; Gottwald, Michaela; Moser, Jasmine; Reicher, Bianca; Schäfer, Bhavapriya Jasmin; Schaper, Roland; Joachim, Anja; Künzel, Frank

    2017-10-15

    Several endoparasites of dogs cannot only be detrimental to their primary host but might also represent a threat to human health because of their zoonotic potential. Due to their high dog population densities, metropolitan areas can be highly endemic for such parasites. We aimed to estimate the prevalence of endoparasites in dogs in the Austrian capital of Vienna by examining a representative number of canine faecal samples and to compare the prevalences with two neighbouring peri-urban and rural regions. In addition we analysed whether the density of dog populations and cleanliness of dog zones correlated with parasite occurrence. We collected 1001 anonymous faecal samples from 55 dog zones from all 23 districts of the federal state of Vienna, as well as 480 faecal samples from the Mödling district and Wolkersdorf with a peri-urban and rural character, respectively. Faeces were examined by flotation and by Baermann technique. Additionally we evaluated 292 Viennese, 102 peri-urban and 50 rural samples for Giardia and Cryptosporidium by GiardiaFASTest ® and CryptoFASTest ® . Samples from "clean" dog zones were compared to samples from "dirty" zones. The infection rate of Toxocara was surprisingly low, ranging from 0.6% to 1.9%. Trichuris was the most frequent helminth (1.8-7.5%) and Giardia the most frequent protozoan (4.0-10.8%). Ancylostomatidae, Crenosoma, Capillaria, Taeniidae, Cystoisospora and Sarcocystis were found in 1.8-2.2%, 0-0.9%, 0-0.9%, 0-0.6%, 0.3-3.1% and 0-0.6% of the samples, respectively. Samples from "dirty" dog zones in Vienna showed a significantly higher rate of parasites overall (p=0.003) and of Trichuris (p=0.048) compared to samples from "clean" dog zones. There were no statistically significant differences in densely vs. less densely populated areas of Vienna. Samples from the rural region of Wolkersdorf had significantly higher overall parasite, Trichuris and Cystoisospora prevalences than the peri-urban Mödling district and Vienna (p

  18. Automating data analysis for two-dimensional gas chromatography/time-of-flight mass spectrometry non-targeted analysis of comparative samples.

    Science.gov (United States)

    Titaley, Ivan A; Ogba, O Maduka; Chibwe, Leah; Hoh, Eunha; Cheong, Paul H-Y; Simonich, Staci L Massey

    2018-03-16

    Non-targeted analysis of environmental samples, using comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC/ToF-MS), poses significant data analysis challenges due to the large number of possible analytes. Non-targeted data analysis of complex mixtures is prone to human bias and is laborious, particularly for comparative environmental samples such as contaminated soil pre- and post-bioremediation. To address this research bottleneck, we developed OCTpy, a Python™ script that acts as a data reduction filter to automate GC × GC/ToF-MS data analysis from LECO ® ChromaTOF ® software and facilitates selection of analytes of interest based on peak area comparison between comparative samples. We used data from polycyclic aromatic hydrocarbon (PAH) contaminated soil, pre- and post-bioremediation, to assess the effectiveness of OCTpy in facilitating the selection of analytes that have formed or degraded following treatment. Using datasets from the soil extracts pre- and post-bioremediation, OCTpy selected, on average, 18% of the initial suggested analytes generated by the LECO ® ChromaTOF ® software Statistical Compare feature. Based on this list, 63-100% of the candidate analytes identified by a highly trained individual were also selected by OCTpy. This process was accomplished in several minutes per sample, whereas manual data analysis took several hours per sample. OCTpy automates the analysis of complex mixtures of comparative samples, reduces the potential for human error during heavy data handling and decreases data analysis time by at least tenfold. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Comparing two sampling methods to engage hard-to-reach communities in research priority setting.

    Science.gov (United States)

    Valerio, Melissa A; Rodriguez, Natalia; Winkler, Paula; Lopez, Jaime; Dennison, Meagen; Liang, Yuanyuan; Turner, Barbara J

    2016-10-28

    Effective community-partnered and patient-centered outcomes research needs to address community priorities. However, optimal sampling methods to engage stakeholders from hard-to-reach, vulnerable communities to generate research priorities have not been identified. In two similar rural, largely Hispanic communities, a community advisory board guided recruitment of stakeholders affected by chronic pain using a different method in each community: 1) snowball sampling, a chain- referral method or 2) purposive sampling to recruit diverse stakeholders. In both communities, three groups of stakeholders attended a series of three facilitated meetings to orient, brainstorm, and prioritize ideas (9 meetings/community). Using mixed methods analysis, we compared stakeholder recruitment and retention as well as priorities from both communities' stakeholders on mean ratings of their ideas based on importance and feasibility for implementation in their community. Of 65 eligible stakeholders in one community recruited by snowball sampling, 55 (85 %) consented, 52 (95 %) attended the first meeting, and 36 (65 %) attended all 3 meetings. In the second community, the purposive sampling method was supplemented by convenience sampling to increase recruitment. Of 69 stakeholders recruited by this combined strategy, 62 (90 %) consented, 36 (58 %) attended the first meeting, and 26 (42 %) attended all 3 meetings. Snowball sampling recruited more Hispanics and disabled persons (all P research, focusing on non-pharmacologic interventions for management of chronic pain. Ratings on importance and feasibility for community implementation differed only on the importance of massage services (P = 0.045) which was higher for the purposive/convenience sampling group and for city improvements/transportation services (P = 0.004) which was higher for the snowball sampling group. In each of the two similar hard-to-reach communities, a community advisory board partnered with researchers

  20. Large Sample Neutron Activation Analysis of Heterogeneous Samples

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Vasilopoulou, T.; Tzika, F.

    2018-01-01

    A Large Sample Neutron Activation Analysis (LSNAA) technique was developed for non-destructive analysis of heterogeneous bulk samples. The technique incorporated collimated scanning and combining experimental measurements and Monte Carlo simulations for the identification of inhomogeneities in large volume samples and the correction of their effect on the interpretation of gamma-spectrometry data. Corrections were applied for the effect of neutron self-shielding, gamma-ray attenuation, geometrical factor and heterogeneous activity distribution within the sample. A benchmark experiment was performed to investigate the effect of heterogeneity on the accuracy of LSNAA. Moreover, a ceramic vase was analyzed as a whole demonstrating the feasibility of the technique. The LSNAA results were compared against results obtained by INAA and a satisfactory agreement between the two methods was observed. This study showed that LSNAA is a technique capable to perform accurate non-destructive, multi-elemental compositional analysis of heterogeneous objects. It also revealed the great potential of the technique for the analysis of precious objects and artefacts that need to be preserved intact and cannot be damaged for sampling purposes. (author)

  1. Cold Spray Deposition of Freestanding Inconel Samples and Comparative Analysis with Selective Laser Melting

    Science.gov (United States)

    Bagherifard, Sara; Roscioli, Gianluca; Zuccoli, Maria Vittoria; Hadi, Mehdi; D'Elia, Gaetano; Demir, Ali Gökhan; Previtali, Barbara; Kondás, Ján; Guagliano, Mario

    2017-10-01

    Cold spray offers the possibility of obtaining almost zero-porosity buildups with no theoretical limit to the thickness. Moreover, cold spray can eliminate particle melting, evaporation, crystallization, grain growth, unwanted oxidation, undesirable phases and thermally induced tensile residual stresses. Such characteristics can boost its potential to be used as an additive manufacturing technique. Indeed, deposition via cold spray is recently finding its path toward fabrication of freeform components since it can address the common challenges of powder-bed additive manufacturing techniques including major size constraints, deposition rate limitations and high process temperature. Herein, we prepared nickel-based superalloy Inconel 718 samples with cold spray technique and compared them with similar samples fabricated by selective laser melting method. The samples fabricated using both methods were characterized in terms of mechanical strength, microstructural and porosity characteristics, Vickers microhardness and residual stresses distribution. Different heat treatment cycles were applied to the cold-sprayed samples in order to enhance their mechanical characteristics. The obtained data confirm that cold spray technique can be used as a complementary additive manufacturing method for fabrication of high-quality freestanding components where higher deposition rate, larger final size and lower fabrication temperatures are desired.

  2. Comparing the performance of cluster random sampling and integrated threshold mapping for targeting trachoma control, using computer simulation.

    Directory of Open Access Journals (Sweden)

    Jennifer L Smith

    Full Text Available Implementation of trachoma control strategies requires reliable district-level estimates of trachomatous inflammation-follicular (TF, generally collected using the recommended gold-standard cluster randomized surveys (CRS. Integrated Threshold Mapping (ITM has been proposed as an integrated and cost-effective means of rapidly surveying trachoma in order to classify districts according to treatment thresholds. ITM differs from CRS in a number of important ways, including the use of a school-based sampling platform for children aged 1-9 and a different age distribution of participants. This study uses computerised sampling simulations to compare the performance of these survey designs and evaluate the impact of varying key parameters.Realistic pseudo gold standard data for 100 districts were generated that maintained the relative risk of disease between important sub-groups and incorporated empirical estimates of disease clustering at the household, village and district level. To simulate the different sampling approaches, 20 clusters were selected from each district, with individuals sampled according to the protocol for ITM and CRS. Results showed that ITM generally under-estimated the true prevalence of TF over a range of epidemiological settings and introduced more district misclassification according to treatment thresholds than did CRS. However, the extent of underestimation and resulting misclassification was found to be dependent on three main factors: (i the district prevalence of TF; (ii the relative risk of TF between enrolled and non-enrolled children within clusters; and (iii the enrollment rate in schools.Although in some contexts the two methodologies may be equivalent, ITM can introduce a bias-dependent shift as prevalence of TF increases, resulting in a greater risk of misclassification around treatment thresholds. In addition to strengthening the evidence base around choice of trachoma survey methodologies, this study illustrates

  3. Results from tests of TFL Hydragard sampling loop

    International Nuclear Information System (INIS)

    Steimke, J.L.

    1995-03-01

    When the Defense Waste Processing Facility (DWPF) is operational, processed radioactive sludge will be transferred in batches to the Slurry Mix Evaporator (SME), where glass frit will be added and the contents concentrated by boiling. Batches of the slurry mixture are transferred from the SME to the Melter Feed Tank (MFT). Hydragard reg-sign sampling systems are used on the SME and the MFT for collecting slurry samples in vials for chemical analysis. An accurate replica of the Hydragard sampling system was built and tested in the thermal Fluids Laboratory (TFL) to determine the hydragard accuracy. It was determined that the original Hydragard valve frequently drew a non-representative sample stream through the sample vial that ranged from frit enriched to frit depleted. The Hydragard valve was modified by moving the plunger and its seat backwards so that the outer surface of the plunger was flush with the inside diameter of the transfer line when the valve was open. The slurry flowing through the vial accurately represented the composition of the slurry in the reservoir for two types of slurries, different dilution factors, a range of transfer flows and a range of vial flows. It was then found that the 15 ml of slurry left in the vial when the Hydragard valve was closed, which is what will be analyzed at DWPF, had a lower ratio of frit to sludge as characterized by the lithium to iron ratio than the slurry flowing through it. The reason for these differences is not understood at this time but it is recommended that additional experimentation be performed with the TFL Hydragard loop to determine the cause

  4. Sample size calculation for comparing two negative binomial rates.

    Science.gov (United States)

    Zhu, Haiyuan; Lakkis, Hassan

    2014-02-10

    Negative binomial model has been increasingly used to model the count data in recent clinical trials. It is frequently chosen over Poisson model in cases of overdispersed count data that are commonly seen in clinical trials. One of the challenges of applying negative binomial model in clinical trial design is the sample size estimation. In practice, simulation methods have been frequently used for sample size estimation. In this paper, an explicit formula is developed to calculate sample size based on the negative binomial model. Depending on different approaches to estimate the variance under null hypothesis, three variations of the sample size formula are proposed and discussed. Important characteristics of the formula include its accuracy and its ability to explicitly incorporate dispersion parameter and exposure time. The performance of the formula with each variation is assessed using simulations. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Solvent Hold Tank Sample Results for MCU-16-934-935-936: June 2016 Monthly Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-08-30

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-934-935-936), pulled on 07/01/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-934-935-936 indicated the Isopar™L concentration is above its nominal level (101%). The modifier (CS-7SB) and the TiDG concentrations are 8% and 29 % below their nominal concentrations. This analysis confirms the solvent may require the addition of TiDG, and possibly of modifier. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, up to 21.1 ± 4 micrograms of mercury per gram of solvent (or 17.5 μg/mL) was detected in this sample (as determined by the XRF method of undigested sample). The current gamma level (1.41E5 dpm/mL) confirmed that the gamma concentration has returned to previous levels (as observed in the late 2015 samples) where the process operated normally and as expected.

  6. 60-Day waste compatibility safety issues and final results for AY-102 grab samples

    Energy Technology Data Exchange (ETDEWEB)

    Nuzum, J.L.

    1997-01-31

    Four grab samples (2AY-96-15, 2AY-96-16, 2AY-96-17, and 2AY-96-18) were taken from Riser 15D of Tank 241-AY-102 on October 8, 1996, and received by 222-S Laboratory on October 8, 1996. These samples were analyzed in accordance with Compatibility Grab Sampling and Analysis Plan (TSAP) and Data Quality Objectives for Tank Farms Waste Compatibility Program (DQO) in support of the Waste Compatibility Program. No notifications were required based on sample results.

  7. Determination of Sr-90 in milk samples from the study of statistical results

    Directory of Open Access Journals (Sweden)

    Otero-Pazos Alberto

    2017-01-01

    Full Text Available The determination of 90Sr in milk samples is the main objective of radiation monitoring laboratories because of its environmental importance. In this paper the concentration of activity of 39 milk samples was obtained through radiochemical separation based on selective retention of Sr in a cationic resin (Dowex 50WX8, 50-100 mesh and subsequent determination by a low-level proportional gas counter. The results were checked by performing the measurement of the Sr concentration by using the flame atomic absorption spectroscopy technique, to finally obtain the mass of 90Sr. From the data obtained a statistical treatment was performed using linear regressions. A reliable estimate of the mass of 90Sr was obtained based on the gravimetric technique, and secondly, the counts per minute of the third measurement in the 90Sr and 90Y equilibrium, without having to perform the analysis. These estimates have been verified with 19 milk samples, obtaining overlapping results. The novelty of the manuscript is the possibility of determining the concentration of 90Sr in milk samples, without the need to perform the third measurement in the equilibrium.

  8. Reducing matrix effect error in EDXRF: Comparative study of using standard and standard less methods for stainless steel samples

    International Nuclear Information System (INIS)

    Meor Yusoff Meor Sulaiman; Masliana Muhammad; Wilfred, P.

    2013-01-01

    Even though EDXRF analysis has major advantages in the analysis of stainless steel samples such as simultaneous determination of the minor elements, analysis can be done without sample preparation and non-destructive analysis, the matrix issue arise from the inter element interaction can make the the final quantitative result to be in accurate. The paper relates a comparative quantitative analysis using standard and standard less methods in the determination of these elements. Standard method was done by plotting regression calibration graphs of the interested elements using BCS certified stainless steel standards. Different calibration plots were developed based on the available certified standards and these stainless steel grades include low alloy steel, austenitic, ferritic and high speed. The standard less method on the other hand uses a mathematical modelling with matrix effect correction derived from Lucas-Tooth and Price model. Further improvement on the accuracy of the standard less method was done by inclusion of pure elements into the development of the model. Discrepancy tests were then carried out for these quantitative methods on different certified samples and the results show that the high speed method is most reliable for determining of Ni and the standard less method for Mn. (Author)

  9. Results of Remediation and Verification Sampling for the 600-270 Horseshoe Landfill

    Energy Technology Data Exchange (ETDEWEB)

    W. S. Thompson

    2005-12-14

    This report presents the results of the 2005 remedial action and verification soil sampling conducted at the 600-270 waste site after removal of soil containing residual concentrations of dichlorodiphenyl trichloroethane and its breakdown products dichlorodiphenyl dichloroethylene and dichlorodiphenyl dichloroethane. The remediation was performed in response to post-closure surface soil sampling performed between 1998 and 2003 that indicated the presence of residual DDT contamination exceeding the Record of Decision for the 1100 Area National Priorities List site cleanup criteria of 1 mg/kg that was established for the original 1994 cleanup activities.

  10. Results of Remediation and Verification Sampling for the 600-270 Horseshoe Landfill

    International Nuclear Information System (INIS)

    Thompson, W.S.

    2005-01-01

    This report presents the results of the 2005 remedial action and verification soil sampling conducted at the 600-270 waste site after removal of soil containing residual concentrations of dichlorodiphenyl trichloroethane and its breakdown products dichlorodiphenyl dichloroethylene and dichlorodiphenyl dichloroethane. The remediation was performed in response to post-closure surface soil sampling performed between 1998 and 2003 that indicated the presence of residual DDT contamination exceeding the Record of Decision for the 1100 Area National Priorities List site cleanup criteria of 1 mg/kg that was established for the original 1994 cleanup activities.

  11. Comparison of Hematologic and Biochemical Test Results in Blood Samples Obtained by Jugular Venipuncture Versus Nail Clip in Moluccan Cockatoos (Cacatua moluccensis).

    Science.gov (United States)

    Bennett, Tracy D; Lejnieks, Daniel V; Koepke, Hoyt; Grimson, Fiona; Szucs, Jennifer; Omaits, Kerri; Lane, Rosalie

    2015-12-01

    In birds, blood samples are often collected from the jugular, medial metatarsal, and basilic vein. Samples are sometimes collected by toe nail clip, but concerns to avoid drawing blood from the nail include pain after nail clips for blood collection, potential differences in complete blood count (CBC) results, and potential contamination with uric acid values. To compare differences in biochemical and hematologic values in blood samples obtained by jugular venipuncture versus toenail clip, blood samples were collected from Moluccan cockatoos (Cacatua moluccensis) (N = 23) and sent to a commercial laboratory for routine CBCs and serum biochemical analysis. Results showed good agreement between venipuncture and nail clip blood samples in red blood cell count, packed cell volume, heterophil count and percentage, lymphocyte count and percentage, aspartate aminotransferase, chloride, creatine phosphokinase, glucose, lactate dehydrogenase, total protein, and uric acid values. Constant bias was found in values of bile acids, cholesterol, and hemoglobin. Proportional bias toward higher values in the jugular sample were found in total white blood cell (WBC) count and inorganic phosphorus. Serum calcium plots revealed a proportional bias toward higher values in the toe nail blood when values were increased. Results suggest some differences in WBC count, bile acids, calcium, cholesterol, hemoglobin, and phosphorus values between blood samples collected by jugular venipuncture and samples collected by toe nail clip, but the differences are mostly minor and, with the possible exception of inorganic phosphorus and marginally elevated or very low WBC counts, are unlikely to affect the use or interpretation of the avian blood panel.

  12. Comparative evaluation of the US Environmental Protection Agency's and the Oak Ridge Institute for Science and Education's environmental survey and site assessment program field sampling procedures

    International Nuclear Information System (INIS)

    Vitkus, T.J.; Bright, T.L.; Roberts, S.A.

    1997-10-01

    At the request of the U.S. Nuclear Regulatory Commission's (NRC's) Headquarters Office, the Environmental Survey and Site Assessment Program (ESSAP) of the Oak Ridge Institute for Science and Education (ORISE) compared the documented procedures that the U.S. Environmental Protection Agency (EPA) and ESSAP use for collecting environmental samples. The project objectives were to review both organizations' procedures applicable to collecting various sample matrices, compare the procedures for similarities and differences, and then to evaluate the reason for any identified procedural differences and their potential impact on ESSAP's sample data quality. The procedures reviewed included those for sampling surface and subsurface soil, surface and groundwater, vegetation, air, and removable surface contamination. ESSAP obtained copies of relevant EPA documents and reviewed and prepared a tabulated summary of each applicable procedure. The methods for collecting and handling each type of sample were evaluated for differences, and where these were identified, the significance and effect of the differences on analytical quality were determined. The results of the comparison showed that, overall, the procedures and methods that EPA and ESSAP use for sample collection are very similar. The number of minor differences noted were the result of restrictions or procedures necessary to ensure sample integrity and prevent the introduction of interfering compounds when samples are to be analyzed for chemical parameters. For most radio nuclide analyses, these additional procedures are not necessary. Another item noted was EPA's inclusion of steps that reduce the potential for sample cross-contamination by preparing (dressing) a location prior to collecting a sample or removing a portion of a sample prior to containerization

  13. Results of initial analyses of the salt (macro) batch 11 Tank 21H qualification samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-23

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 11 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 11 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amounts of solids, or unusual colors. Further sample results will be reported in a future document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).

  14. 45-Day safety screen results for Tank 241-C-101, auger sample 95-AUG-019

    International Nuclear Information System (INIS)

    Sasaki, L.M.

    1995-01-01

    One auger sample from Tank 241-C-101 was received by the 222-S Laboratory and underwent safety screening analyses--differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha analysis--in accordance with the tank characterization plan. Analytical results for the TGA on the crust sample (the uppermost portion of the auger sample) (sample number S95T000823) were less than the safety screening notification limit of 17 weight percent water. Verbal and written notifications were made on May 3, 1995. No exotherms were observed in the DSC analyses and the total alpha results were well below the safety screening notification limit. This report includes the primary safety screening results obtained from the analyses and copies of all DSC and TGA raw data scans as requested per the TCP. Although not included in this report, a photograph of the extruded sample was taken and is available. This report also includes bulk density measurements required by Characterization Plant Engineering. Additional analyses (pH, total organic carbon, and total inorganic carbon) are being performed on the drainable liquid at the request of Characterization Process Control; these analyses will be reported at a later date in a final report for this auger sample. Tank C-101 is not part of any of the four Watch Lists

  15. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    Science.gov (United States)

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  16. Solvent Hold Tank Sample Results for MCU-16-596-597-598: April 2016 Monthly Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Advanced Characterization and Processing; Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Research Support

    2016-07-12

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-596-597-598), pulled on 04/30/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-596-597-598 indicated the Isopar™L concentration is above its nominal level (102%). The modifier (CS-7SB) is 14% below its nominal concentration, while the TiDG and MaxCalix concentrations are at and above their nominal concentrations, respectively. This analysis confirms the solvent may require the addition of modifier. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

  17. Moessbauer and XRD Comparative Study of Host Rock and Iron Rich Mineral Samples from Paz del Rio Iron Ore Mineral Mine in Colombia

    International Nuclear Information System (INIS)

    Fajardo, M.; Perez Alcazar, G. A.; Moreira, A. M.; Speziali, N. L.

    2004-01-01

    A comparative study between the host rock and the iron rich mineral samples from the Paz del Rio iron ore mineral mine in Colombia was performed using X-ray diffraction and Moessbauer spectroscopy. Diffraction results of the iron rich mineral sample show that goethite, hematite, quartz, kaolinite and siderite are the main phases, and that a small amount of illite is also present. By Moessbauer spectroscopy at room temperature (RT) the presence of all the above mentioned phases was detected except quartz as well as an additional presence of small amount of biotite. The goethite, which appears as four sextets with hyperfine fields of 33.5, 30.5, 27.5 and 18.5 T, respectively, is the majority phase. This result shows the different grades of formation of this oxyhydroxide. The Moessbauer spectrum of this sample at 80 K presents the same phases obtained at RT without any superparamagnetic effect. In this case the goethite appears as two sextets. Diffraction results of the host rock sample show a large amount of quartz and kaolinite and small amounts of illite and biotite, whereas by Moessbauer spectroscopy illite, kaolinite and biotite were detected.

  18. Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air

    International Nuclear Information System (INIS)

    Langton, C. A.; Almond, P. M.

    2013-01-01

    The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO 4 - in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O 4 - , which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this report. The Cr oxidation front

  19. Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study.

    Science.gov (United States)

    De Kesel, Pieter M M; Lambert, Willy E; Stove, Christophe P

    2015-06-30

    Volumetric absorptive microsampling (VAMS) is a novel sampling technique that allows the straightforward collection of an accurate volume of blood (approximately 10μL) from a drop or pool of blood by dipping an absorbent polymeric tip into it. The resulting blood microsample is dried and analyzed as a whole. The aim of this study was to evaluate the potential of VAMS to overcome the hematocrit bias, an important issue in the analysis of dried blood microsamples. An LC-MS/MS method for analysis of the model compounds caffeine and paraxanthine in VAMS samples was fully validated and fulfilled all pre-established criteria. In conjunction with previously validated procedures for dried blood spots (DBS) and blood, this allowed us to set up a meticulous comparative study in which both compounds were determined in over 80 corresponding VAMS, DBS and liquid whole blood samples. These originated from authentic human patient samples, covering a wide hematocrit range (0.21-0.50). By calculating the differences with reference whole blood concentrations, we found that analyte concentrations in VAMS samples were not affected by a bias that changed over the evaluated hematocrit range, in contrast to DBS results. However, VAMS concentrations tend to overestimate whole blood concentrations, as a consistent positive bias was observed. A different behavior of VAMS samples prepared from incurred and spiked blood, combined with a somewhat reduced recovery of caffeine and paraxanthine from VAMS tips at high hematocrit values, an effect that was not observed for DBS using a very similar extraction procedure, was found to be at the basis of the observed VAMS-whole blood deviations. Based on this study, being the first in which the validity and robustness of VAMS is evaluated by analyzing incurred human samples, it can be concluded that VAMS effectively assists in eliminating the effect of hematocrit. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Large sample neutron activation analysis of a reference inhomogeneous sample

    International Nuclear Information System (INIS)

    Vasilopoulou, T.; Athens National Technical University, Athens; Tzika, F.; Stamatelatos, I.E.; Koster-Ammerlaan, M.J.J.

    2011-01-01

    A benchmark experiment was performed for Neutron Activation Analysis (NAA) of a large inhomogeneous sample. The reference sample was developed in-house and consisted of SiO 2 matrix and an Al-Zn alloy 'inhomogeneity' body. Monte Carlo simulations were employed to derive appropriate correction factors for neutron self-shielding during irradiation as well as self-attenuation of gamma rays and sample geometry during counting. The large sample neutron activation analysis (LSNAA) results were compared against reference values and the trueness of the technique was evaluated. An agreement within ±10% was observed between LSNAA and reference elemental mass values, for all matrix and inhomogeneity elements except Samarium, provided that the inhomogeneity body was fully simulated. However, in cases that the inhomogeneity was treated as not known, the results showed a reasonable agreement for most matrix elements, while large discrepancies were observed for the inhomogeneity elements. This study provided a quantification of the uncertainties associated with inhomogeneity in large sample analysis and contributed to the identification of the needs for future development of LSNAA facilities for analysis of inhomogeneous samples. (author)

  1. Tank 101-SY Window E core sample: Interpretation of results

    International Nuclear Information System (INIS)

    Reynolds, D.A.

    1993-02-01

    A full depth core sample was taken for tank 241-SY-101 in December 1991 during a time period called ''Window E.'' This was the second full depth core sample from this tank during the year. The core had two major portions that are known as the convective zone and the nonconvective zone. A crust was on the top of tank but as poorly sampled. The analysis of the Window E core sample stressed segment composite chemical analysis instead of segment by segment as in Window C. Adiabatic calorimetry on samples from both cores showed a slow self heating reaction above 150 degrees C on dried samples. The exothermic events were milder than similar synthetic samples. The chemical and physical properties complemented the information from Window C. The Window E material from the convective zone was more viscous than the Window C convective zone material. The nonconvective zone viscosities were similar for both cores. Heating and dilution tests were made to test mitigation concepts

  2. Tank 101-SY Window E core sample: Interpretation of results

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, D.A.

    1993-02-01

    A full depth core sample was taken for tank 241-SY-101 in December 1991 during a time period called ``Window E.`` This was the second full depth core sample from this tank during the year. The core had two major portions that are known as the convective zone and the nonconvective zone. A crust was on the top of tank but as poorly sampled. The analysis of the Window E core sample stressed segment composite chemical analysis instead of segment by segment as in Window C. Adiabatic calorimetry on samples from both cores showed a slow self heating reaction above 150{degrees}C on dried samples. The exothermic events were milder than similar synthetic samples. The chemical and physical properties complemented the information from Window C. The Window E material from the convective zone was more viscous than the Window C convective zone material. The nonconvective zone viscosities were similar for both cores. Heating and dilution tests were made to test mitigation concepts.

  3. Sample results from the interim salt disposition program macrobatch 9 tank 21H qualification samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-11-01

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 9 for the Interim Salt Disposition Program (ISDP). This document reports characterization data on the samples of Tank 21H.

  4. Blood gas sample spiking with total parenteral nutrition, lipid emulsion, and concentrated dextrose solutions as a model for predicting sample contamination based on glucose result.

    Science.gov (United States)

    Jara-Aguirre, Jose C; Smeets, Steven W; Wockenfus, Amy M; Karon, Brad S

    2018-05-01

    Evaluate the effects of blood gas sample contamination with total parenteral nutrition (TPN)/lipid emulsion and dextrose 50% (D50) solutions on blood gas and electrolyte measurement; and determine whether glucose concentration can predict blood gas sample contamination with TPN/lipid emulsion or D50. Residual lithium heparin arterial blood gas samples were spiked with TPN/lipid emulsion (0 to 15%) and D50 solutions (0 to 2.5%). Blood gas (pH, pCO2, pO2), electrolytes (Na+, K+ ionized calcium) and hemoglobin were measured with a Radiometer ABL90. Glucose concentration was measured in separated plasma by Roche Cobas c501. Chart review of neonatal blood gas results with glucose >300 mg/dL (>16.65 mmol/L) over a seven month period was performed to determine whether repeat (within 4 h) blood gas results suggested pre-analytical errors in blood gas results. Results were used to determine whether a glucose threshold could predict contamination resulting in blood gas and electrolyte results with greater than laboratory-defined allowable error. Samples spiked with 5% or more TPN/lipid emulsion solution or 1% D50 showed glucose concentration >500 mg/dL (>27.75 mmol/L) and produced blood gas (pH, pO 2 , pCO 2 ) results with greater than laboratory-defined allowable error. TPN/lipid emulsion, but not D50, produced greater than allowable error in electrolyte (Na + ,K + ,Ca ++ ,Hb) results at these concentrations. Based on chart review of 144 neonatal blood gas results with glucose >250 mg/dL received over seven months, four of ten neonatal intensive care unit (NICU) patients with glucose results >500 mg/dL and repeat blood gas results within 4 h had results highly suggestive of pre-analytical error. Only 3 of 36 NICU patients with glucose results 300-500 mg/dL and repeat blood gas results within 4 h had clear pre-analytical errors in blood gas results. Glucose concentration can be used as an indicator of significant blood sample contamination with either TPN

  5. Comparing rapid methods for detecting Listeria in seafood and environmental samples using the most probably number (MPN) technique.

    Science.gov (United States)

    Cruz, Cristina D; Win, Jessicah K; Chantarachoti, Jiraporn; Mutukumira, Anthony N; Fletcher, Graham C

    2012-02-15

    The standard Bacteriological Analytical Manual (BAM) protocol for detecting Listeria in food and on environmental surfaces takes about 96 h. Some studies indicate that rapid methods, which produce results within 48 h, may be as sensitive and accurate as the culture protocol. As they only give presence/absence results, it can be difficult to compare the accuracy of results generated. We used the Most Probable Number (MPN) technique to evaluate the performance and detection limits of six rapid kits for detecting Listeria in seafood and on an environmental surface compared with the standard protocol. Three seafood products and an environmental surface were inoculated with similar known cell concentrations of Listeria and analyzed according to the manufacturers' instructions. The MPN was estimated using the MPN-BAM spreadsheet. For the seafood products no differences were observed among the rapid kits and efficiency was similar to the BAM method. On the environmental surface the BAM protocol had a higher recovery rate (sensitivity) than any of the rapid kits tested. Clearview™, Reveal®, TECRA® and VIDAS® LDUO detected the cells but only at high concentrations (>10(2) CFU/10 cm(2)). Two kits (VIP™ and Petrifilm™) failed to detect 10(4) CFU/10 cm(2). The MPN method was a useful tool for comparing the results generated by these presence/absence test kits. There remains a need to develop a rapid and sensitive method for detecting Listeria in environmental samples that performs as well as the BAM protocol, since none of the rapid tests used in this study achieved a satisfactory result. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach.

    Science.gov (United States)

    Mischnik, Alexander; Mieth, Markus; Busch, Cornelius J; Hofer, Stefan; Zimmermann, Stefan

    2012-08-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis.

  7. Molecular Weights of Bovine and Porcine Heparin Samples: Comparison of Chromatographic Methods and Results of a Collaborative Survey

    Directory of Open Access Journals (Sweden)

    Sabrina Bertini

    2017-07-01

    Full Text Available In a collaborative study involving six laboratories in the USA, Europe, and India the molecular weight distributions of a panel of heparin sodium samples were determined, in order to compare heparin sodium of bovine intestinal origin with that of bovine lung and porcine intestinal origin. Porcine samples met the current criteria as laid out in the USP Heparin Sodium monograph. Bovine lung heparin samples had consistently lower average molecular weights. Bovine intestinal heparin was variable in molecular weight; some samples fell below the USP limits, some fell within these limits and others fell above the upper limits. These data will inform the establishment of pharmacopeial acceptance criteria for heparin sodium derived from bovine intestinal mucosa. The method for MW determination as described in the USP monograph uses a single, broad standard calibrant to characterize the chromatographic profile of heparin sodium on high-resolution silica-based GPC columns. These columns may be short-lived in some laboratories. Using the panel of samples described above, methods based on the use of robust polymer-based columns have been developed. In addition to the use of the USP’s broad standard calibrant for heparin sodium with these columns, a set of conditions have been devised that allow light-scattering detected molecular weight characterization of heparin sodium, giving results that agree well with the monograph method. These findings may facilitate the validation of variant chromatographic methods with some practical advantages over the USP monograph method.

  8. Molecular Weights of Bovine and Porcine Heparin Samples: Comparison of Chromatographic Methods and Results of a Collaborative Survey.

    Science.gov (United States)

    Bertini, Sabrina; Risi, Giulia; Guerrini, Marco; Carrick, Kevin; Szajek, Anita Y; Mulloy, Barbara

    2017-07-19

    In a collaborative study involving six laboratories in the USA, Europe, and India the molecular weight distributions of a panel of heparin sodium samples were determined, in order to compare heparin sodium of bovine intestinal origin with that of bovine lung and porcine intestinal origin. Porcine samples met the current criteria as laid out in the USP Heparin Sodium monograph. Bovine lung heparin samples had consistently lower average molecular weights. Bovine intestinal heparin was variable in molecular weight; some samples fell below the USP limits, some fell within these limits and others fell above the upper limits. These data will inform the establishment of pharmacopeial acceptance criteria for heparin sodium derived from bovine intestinal mucosa. The method for MW determination as described in the USP monograph uses a single, broad standard calibrant to characterize the chromatographic profile of heparin sodium on high-resolution silica-based GPC columns. These columns may be short-lived in some laboratories. Using the panel of samples described above, methods based on the use of robust polymer-based columns have been developed. In addition to the use of the USP's broad standard calibrant for heparin sodium with these columns, a set of conditions have been devised that allow light-scattering detected molecular weight characterization of heparin sodium, giving results that agree well with the monograph method. These findings may facilitate the validation of variant chromatographic methods with some practical advantages over the USP monograph method.

  9. The meaning of results. Understanding comparative risk assessments of energy options

    International Nuclear Information System (INIS)

    Wilson, R.; Holland, M.; Rabl, A.; Dreicer, M.

    1999-01-01

    Results of comparative risk assessments can be used for a range of potential applications: choice and balance of technologies for strategic energy planning; choice of a new power plant; optimal dispatching of existing plants; optimization of regulations (emission limits, environmental quality objectives such as air quality limits, tradable permits, pollution taxes); accounting for climate change. When reporting the results of comparative risk assessment, a number of factors should be clear: precise nature of the energy system being assessed; what has been excluded from the analysis; sources of data used in assessment; assumptions that have been made; and what the analysts and other experts have regarded as the key sensitivities in the analysis. If all factors are addressed, the results of comparative risk assessment will prove to be an essential resource for making the best decisions about energy options and policies

  10. A comparative study of 232Th and 238U activity estimation in soil samples by gamma spectrometry and neutron activation analysis technique

    International Nuclear Information System (INIS)

    Anilkumar, Rekha; Anilkumar, S.; Narayani, K.; Babu, D.A.R.; Sharma, D.N.

    2012-01-01

    Neutron activation analysis (NAA) is a well-established analytical technique. It has many advantages as compared to the other commonly used techniques. NAA can be performed in a variety of ways depending on the element, its activity level in the sample, interference from the sample matrix and other elements, etc. This technique is used to get high analytical sensitivity and low detection limits (ppm to ppb). The high sensitivity is due to the irradiation at high neutron flux available from the research reactors and the activity measurement is done using high resolution HPGe detectors. In this paper, the activity estimation of soil samples using neutron activation and direct gamma spectrometry methods are compared. Even though the weights of samples considered and samples preparation methods are different for these two methods, the estimated activity values are comparable. (author)

  11. Social Connectedness and Life Satisfaction: Comparing Mean Levels for 2 Undergraduate Samples and Testing for Improvement Based on Brief Counseling

    Science.gov (United States)

    Blau, Gary; DiMino, John; DeMaria, Peter A.; Beverly, Clyde; Chessler, Marcy; Drennan, Rob

    2016-01-01

    Objectives: Comparing the mean levels of social connectedness and life satisfaction, and analyzing their relationship for 2 undergraduate samples, and testing for an increase in their means for a brief counseling sample. Participants: Between October 2013 and May 2015, 3 samples were collected: not-in-counseling (NIC; n = 941), initial counseling…

  12. Solvent hold tank sample results for MCU-16-1363-1364-1365: November 2016 monthly sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-16

    Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1363-1364-1365), pulled on 11/15/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1363-1364-1365 indicated the Isopar™L concentration is at its nominal level (100%). The extractant (MaxCalix) and the modifier (CS- 7SB) are 8% and 2 % below their nominal concentrations. The suppressor (TiDG) is 7% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.

  13. Solvent hold tank sample results for MCU-16-1317-1318-1319: September 2016 monthly sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-16

    Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1317-1318-1319), pulled on 09/12/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1317-1318-1319 indicated the Isopar™L concentration is above its nominal level (102%). The extractant (MaxCalix) and the modifier (CS-7SB) are 5% and 9% below their nominal concentrations. The suppressor (TiDG) is 76% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.

  14. Solvent hold tank sample results for MCU-16-1247-1248-1249: August 2016 monthly sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-16

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-1247-1248-1249), pulled on 08/22/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1247-1248-1249 indicated the Isopar™L concentration is above its nominal level (101%). The extractant (MaxCalix) and the modifier (CS-7SB) are 7% and 9 % below their nominal concentrations. The suppressor (TiDG) is 63% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.

  15. What Makes Professional Development Effective? Results from a National Sample of Teachers.

    Science.gov (United States)

    Garet, Michael S.; Porter, Andrew C.; Desimone, Laura; Birman, Beatrice F.; Yoon, Kwang Suk

    2001-01-01

    Used a national probability sample of 1,027 mathematics and science teachers to provide a large-scale empirical comparison of effects of different characteristics of professional development on teachers' learning. Results identify three core features of professional development that have significant positive effects on teachers' self-reported…

  16. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies.

    Science.gov (United States)

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung Hoi

    2017-03-01

    ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol. The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions (serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods. ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤1+ reaction grade do.

  17. Interval estimation methods of the mean in small sample situation and the results' comparison

    International Nuclear Information System (INIS)

    Wu Changli; Guo Chunying; Jiang Meng; Lin Yuangen

    2009-01-01

    The methods of the sample mean's interval estimation, namely the classical method, the Bootstrap method, the Bayesian Bootstrap method, the Jackknife method and the spread method of the Empirical Characteristic distribution function are described. Numerical calculation on the samples' mean intervals is carried out where the numbers of the samples are 4, 5, 6 respectively. The results indicate the Bootstrap method and the Bayesian Bootstrap method are much more appropriate than others in small sample situation. (authors)

  18. Status report on the Zagreb Radiocarbon Laboratory - AMS and LSC results of VIRI intercomparison samples

    Science.gov (United States)

    Sironić, Andreja; Krajcar Bronić, Ines; Horvatinčić, Nada; Barešić, Jadranka; Obelić, Bogomil; Felja, Igor

    2013-01-01

    A new line for preparation of the graphite samples for 14C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. 14C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 ± 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  19. Status report on the Zagreb Radiocarbon Laboratory - AMS and LSC results of VIRI intercomparison samples

    Energy Technology Data Exchange (ETDEWEB)

    Sironic, Andreja [Department of Experimental Physics, Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia); Krajcar Bronic, Ines, E-mail: krajcar@irb.hr [Department of Experimental Physics, Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia); Horvatincic, Nada; Baresic, Jadranka; Obelic, Bogomil; Felja, Igor [Department of Experimental Physics, Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia)

    2013-01-15

    A new line for preparation of the graphite samples for {sup 14}C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. {sup 14}C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 {+-} 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  20. Comparative sensitivity and inhibitor tolerance of GlobalFiler® PCR Amplification and Investigator® 24plex QS kits for challenging samples.

    Science.gov (United States)

    Elwick, Kyleen; Mayes, Carrie; Hughes-Stamm, Sheree

    2018-02-17

    In cases such as mass disasters or missing persons, human remains are challenging to identify as they may be fragmented, burnt, been buried, decomposed, and/or contain inhibitory substances. This study compares the performance of a relatively new STR kit in the US market (Investigator® 24plex QS kit; Qiagen) with the GlobalFiler® PCR Amplification kit (Thermo Fisher Scientific) when genotyping highly inhibited and low level DNA samples. In this study, DNA samples ranging from 1 ng to 7.8 pg were amplified to define the sensitivity of two systems. In addition, DNA (1 ng and 0.1 ng input amounts) was spiked with various concentrations of five inhibitors common to human remains (humic acid, melanin, hematin, collagen, calcium). Furthermore, bone (N = 5) and tissue samples from decomposed human remains (N = 6) were used as mock casework samples for comparative analysis with both STR kits. The data suggest that the GlobalFiler® kit may be slightly more sensitive than the Investigator® kit. On average STR profiles appeared to be more balanced and average peak heights were higher when using the GlobalFiler® kit. However, the data also show that the Investigator® kit may be more tolerant to common PCR inhibitors. While both STR kits showed a decrease in alleles as the inhibitor concentration increased, more complete profiles were obtained when the Investigator® kit was used. Of the 11 bone and decomposed tissue samples tested, 8 resulted in more complete and balanced STR profiles when amplified with the GlobalFiler® kit. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Comparing the effect of the order of cell Collection for Pap Smear on the results of cytologic Diagnosis

    Directory of Open Access Journals (Sweden)

    parvin Rahnama

    2005-08-01

    We observed higher proportion of atypical squamous cells of undetermined significance (ASCUS detection in the spatula- first group (33 cases, 59% compared with brush- first group (20 cases, 3.6% which is insignificant (P=0.09. This study showed that the ability of squamous intraepithelial lesion (SIL detection in spatula- first group (27 cases, 4.8%, was comparable to brush-first group (23 cases, 4.1%. Conclusions: Because reported SIL cases are higher when samples are first taken from exocervix and rate of blood contamination increases when samples are taken from endocervix (p=0.004, it is better to take samples first from exocervix for Pap Smear. This strategy increases the chance of diagnosis of cellular lesions of cervix.

  2. Bipolar mixed features - Results from the comparative effectiveness for bipolar disorder (Bipolar CHOICE) study.

    Science.gov (United States)

    Tohen, Mauricio; Gold, Alexandra K; Sylvia, Louisa G; Montana, Rebecca E; McElroy, Susan L; Thase, Michael E; Rabideau, Dustin J; Nierenberg, Andrew A; Reilly-Harrington, Noreen A; Friedman, Edward S; Shelton, Richard C; Bowden, Charles L; Singh, Vivek; Deckersbach, Thilo; Ketter, Terence A; Calabrese, Joseph R; Bobo, William V; McInnis, Melvin G

    2017-08-01

    DSM-5 changed the criteria from DSM-IV for mixed features in mood disorder episodes to include non-overlapping symptoms of depression and hypomania/mania. It is unknown if, by changing these criteria, the same group would qualify for mixed features. We assessed how those meeting DSM-5 criteria for mixed features compare to those meeting DSM-IV criteria. We analyzed data from 482 adult bipolar patients in Bipolar CHOICE, a randomized comparative effectiveness trial. Bipolar diagnoses were confirmed through the MINI International Neuropsychiatric Interview (MINI). Presence and severity of mood symptoms were collected with the Bipolar Inventory of Symptoms Scale (BISS) and linked to DSM-5 and DSM-IV mixed features criteria. Baseline demographics and clinical variables were compared between mood episode groups using ANOVA for continuous variables and chi-square tests for categorical variables. At baseline, the frequency of DSM-IV mixed episodes diagnoses obtained with the MINI was 17% and with the BISS was 20%. Using DSM-5 criteria, 9% of participants met criteria for hypomania/mania with mixed features and 12% met criteria for a depressive episode with mixed features. Symptom severity was also associated with increased mixed features with a high rate of mixed features in patients with mania/hypomania (63.8%) relative to those with depression (8.0%). Data on mixed features were collected at baseline only and thus do not reflect potential patterns in mixed features within this sample across the study duration. The DSM-5 narrower, non-overlapping definition of mixed episodes resulted in fewer patients who met mixed criteria compared to DSM-IV. Copyright © 2017. Published by Elsevier B.V.

  3. Results of a comparative study on insulin radioimmunoassay in 36 Italian laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Costantini, A; Lostia, O; Malvano, R; Rolleri, E; Taggi, F; Zucchelli, G C [Istituto Superiore di Sanita, Rome (Italy); Consiglio Nazionale delle Ricerche, Pisa (Italy))

    1975-12-01

    An interlaboratory study in which the insulin contents of five plasma samples were estimated in 36 italian laboratories was coordinated by the Istituto Superiore di Sanita (National Institute of Health) and the Consiglio Nazionale delle Ricerche (National Research Council). A rather large between-laboratory variability resulted, though the ranking of samples according to their insulin concentrations was practically the same. A significant dependence of estimates on the method used was established. The analysis of data aimed at defining the possible reasons of the assay variability is reported and discussed.

  4. Ordinary or peculiar men? Comparing the customers of prostitutes with a nationally representative sample of men.

    Science.gov (United States)

    Monto, Martin A; Milrod, Christine

    2014-07-01

    Recent media attention implies that prostitution seeking is widespread, an "ordinary" aspect of masculine sexual behavior. Other accounts suggest that customers are "peculiar," characterized by distinct qualities, perversions, or psychological impairments. Using the nationally representative General Social Survey (GSS), this study demonstrates that prostitution seeking is relatively uncommon. Only about 14% of men in the United States report having ever paid for sex, and only 1% report having done so during the previous year. Furthermore, this study dissects whether customers are ordinary or peculiar by comparing a new sample of active customers who solicit sex on the Internet with an older sample of arrested customers, a sample of customers from the GSS, and a nationally representative sample of noncustomers. The customers of Internet sexual service providers differed greatly from men in general and also from other customers. The remaining samples of customers differed slightly from noncustomers in general. We argue for a balanced perspective that recognizes the significant variety among customers. There is no evidence of a peculiar quality that differentiates customers in general from men who have not paid for sex. © The Author(s) 2013.

  5. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  6. Solvent Hold Tank Sample Results for MCU-16-1247-1248-1249: August 2016 Monthly Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-01-12

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-1247-1248-1249), pulled on 08/22/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1247-1248-1249 indicated the Isopar™L concentration is above its nominal level (101%). The extractant (MaxCalix) and the modifier (CS-7SB) are 7% and 9 % below their nominal concentrations. The suppressor (TiDG) is 63% below its nominal concentration. This analysis confirms the solvent may require the addition of TiDG, and possibly of modifier and MaxCalix to restore then to nominal levels. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. At the time of writing this report, A solvent trim batch containing TiDG, modifier and MaxCalix, was added to the SHT (October 2016) and expect the concentration of these components to be at their nominal values.

  7. Results of Macroinvertebrate Sampling Conducted at 33 SRS Stream Locations, July--August 1993

    Energy Technology Data Exchange (ETDEWEB)

    Specht, W.L.

    1994-12-01

    In order to assess the health of the macroinvertebrate communities of SRS streams, the macroinvertebrate communities at 30 stream locations on SRS were sampled during the summer of 1993, using Hester-Dendy multiplate samplers. In addition, three off-site locations in the Upper Three Runs drainage were sampled in order to assess the potential for impact from off-site activities. In interpreting the data, it is important to recognize that these data were from a single set of collections. Macroinvertebrate communities often undergo considerable temporal variation, and are also greatly influenced by such factors as water depth, water velocity, and available habitat. These stations were selected with the intent of developing an on-going sampling program at a smaller number of stations, with the selection of the stations to be based largely upon the results of this preliminary sampling program. When stations within a given stream showed similar results, fewer stations would be sampled in the future. Similarly, if a stream appeared to be perturbed, additional stations or chemical analyses might be added so that the source of the perturbation could be identified. In general, unperturbed streams will contain more taxa than perturbed streams, and the distribution of taxa among orders or families will differ. Some groups of macroinvertebrates, such as Ephemeroptera (mayflies), Plecoptera (stoneflies) and Trichoptera (caddisflies), which are collectively called EPT taxa, are considered to be relatively sensitive to most kinds of stream perturbation; therefore a reduced number of EPT taxa generally indicates that the stream has been subject to chemical or physical stressors. In coastal plain streams, EPT taxa are generally less dominant than in streams with rocky substrates, while Chironomidae (midges) are more abundant. (Abstract Truncated)

  8. The Comparing Options for Management: Patient-centered Results for Uterine Fibroids (COMPARE-UF) Registry: Rationale and Design.

    Science.gov (United States)

    Stewart, Elizabeth A; Lytle, Barbara L; Thomas, Laine; Wegienka, Ganesa R; Jacoby, Vanessa; Diamond, Michael P; Nicholson, Wanda K; Anchan, Raymond M; Venable, Sateria; Wallace, Kedra; Marsh, Erica E; Maxwell, George L; Borah, Bijan J; Catherino, William H; Myers, Evan R

    2018-05-08

    To design and establish a uterine fibroid (UF) registry based in the United States (US) to provide comparative effectiveness data regarding UF treatment. We report here the design and initial recruitment for the Comparing Options for Management: Patient-centered Results for Uterine Fibroids (COMPARE-UF) registry (Clinicaltrials.gov, NCT02260752), funded by the Agency for Healthcare Research and Quality (AHRQ) in collaboration with the-Patient-Centered Outcomes Research Institute (PCORI). COMPARE-UF is designed to help answer critical questions about treatment options for women with symptomatic UF. Women undergoing a procedure for UF (hysterectomy, myomectomy [abdominal, hysteroscopic, vaginal and laparoscopic/robotic], endometrial ablation, radiofrequency fibroid ablation, uterine artery embolization, magnetic resonance guided focused ultrasound or progestin-releasing intrauterine device insertion) at one of the COMPARE-UF sites are invited to participate in a prospective registry with three years follow-up for post-procedural outcomes. Enrolled participants provide annual follow-up through an online portal or through traditional phone contact. A central data abstraction center provides information obtained from imaging, operative or procedural notes and pathology reports. Women with uterine fibroids and other stakeholders are a key part of the COMPARE-UF registry and participate at all points from study design to dissemination of results. We built a network of nine clinical sites across the US with expertise in the care of women with UF to capture geographic, racial, ethnic and procedural diversity. Of the initial 2031 women enrolled in COMPARE-UF, 42% are self-identified as Black or African-American and 40% are age 40 years or younger with 16% of participants under age 35. Women undergoing myomectomy comprise the largest treatment group at 46% of all procedures with laparoscopic or robotic myomectomy comprising the largest subset of myomectomies at 19% of all

  9. Results of 90Sr and 239+240Pu, 238Pu, 241Am measurements in some samples of mushrooms and forest soil from Poland

    International Nuclear Information System (INIS)

    Mietelski, J.W.; Larosa, J.; Ghods, A.

    1992-01-01

    Strontium-90, plutonium and americium activity concentrations in a few samples of forest soils, some species of mushrooms and fern leaves were determined. These results are compared with caesium activity concentrations in the same materials obtained in a previous work. Radiochemical procedures are described. The origin of the contamination (Chernobyl accident or nuclear test explosion release) is discussed. The 90 Sr activity concentration ranges from 0.6 Bq/kg (mushroom samples) to 48.4 Bq/kg (fern leaves). For 239+240 Pu, it ranges from not detected above background (mushrooms, fern) to 10.8 Bq/kg (humus layer of forest soil). The maximum concentration of 241 Am is found to be 2.4 Bq/kg (humus sample) and for 238 Pu it is 0.85 Bq/kg (also in the humus sample). (author). 12 refs, 9 figs, 7 tabs

  10. Solvent hold tank sample results for MCU-16-1317-1318-1319. September 2016 monthly sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-01-01

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-1317-1318-1319), pulled on 09/12/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1317-1318-1319 indicated the Isopar™L concentration is above its nominal level (102%). The extractant (MaxCalix) and the modifier (CS-7SB) are 5% and 10 % below their nominal concentrations. The suppressor (TiDG) is 77% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below. This analysis confirms the Isopar™ addition to the solvent in August. This analysis also indicates the solvent may require the addition of TiDG, and possibly of modifier to restore them to nominal levels.

  11. Comparative Study of the Effect of Sample Pretreatment and Extraction on the Determination of Flavonoids from Lemon (Citrus limon)

    Science.gov (United States)

    Ledesma-Escobar, Carlos A.; Priego-Capote, Feliciano; Luque de Castro, María D.

    2016-01-01

    Background Flavonoids have shown to exert multiple beneficial effects on human health, being also appreciated by both food and pharmaceutical industries. Citrus fruits are a key source of flavonoids, thus promoting studies to obtain them. Characteristics of these studies are the discrepancies among sample pretreatments and among extraction methods, and also the scant number of comparative studies developed so far. Objective Evaluate the effect of both the sample pretreatment and the extraction method on the profile of flavonoids isolated from lemon. Results Extracts from fresh, lyophilized and air-dried samples obtained by shaking extraction (SE), ultrasound-assisted extraction (USAE), microwave-assisted extraction (MAE) and superheated liquid extraction (SHLE) were analyzed by LC–QTOF MS/MS, and 32 flavonoids were tentatively identified using MS/MS information. ANOVA applied to the data from fresh and dehydrated samples and from extraction by the different methods revealed that 26 and 32 flavonoids, respectively, were significant (p≤0.01). The pairwise comparison (Tukey HSD; p≤0.01) showed that lyophilized samples are more different from fresh samples than from air-dried samples; also, principal component analysis (PCA) showed a clear discrimination among sample pretreatment strategies and suggested that such differences are mainly created by the abundance of major flavonoids. On the other hand, pairwise comparison of extraction methods revealed that USAE and MAE provided quite similar extracts, being SHLE extracts different from the other two. In this case, PCA showed a clear discrimination among extraction methods, and their position in the scores plot suggests a lower abundance of flavonoids in the extracts from SHLE. In the two PCA the loadings plots revealed a trend to forming groups according to flavonoid aglycones. Conclusions The present study shows clear discrimination caused by both sample pretreatments and extraction methods. Under the studied

  12. Retained Gas Sampling Results for the Flammable Gas Program

    International Nuclear Information System (INIS)

    Bates, J.M.; Mahoney, L.A.; Dahl, M.E.; Antoniak, Z.I.

    1999-01-01

    The key phenomena of the Flammable Gas Safety Issue are generation of the gas mixture, the modes of gas retention, and the mechanisms causing release of the gas. An understanding of the mechanisms of these processes is required for final resolution of the safety issue. Central to understanding is gathering information from such sources as historical records, tank sampling data, tank process data (temperatures, ventilation rates, etc.), and laboratory evaluations conducted on tank waste samples

  13. Retained Gas Sampling Results for the Flammable Gas Program

    Energy Technology Data Exchange (ETDEWEB)

    J.M. Bates; L.A. Mahoney; M.E. Dahl; Z.I. Antoniak

    1999-11-18

    The key phenomena of the Flammable Gas Safety Issue are generation of the gas mixture, the modes of gas retention, and the mechanisms causing release of the gas. An understanding of the mechanisms of these processes is required for final resolution of the safety issue. Central to understanding is gathering information from such sources as historical records, tank sampling data, tank process data (temperatures, ventilation rates, etc.), and laboratory evaluations conducted on tank waste samples.

  14. Some connections between importance sampling and enhanced sampling methods in molecular dynamics.

    Science.gov (United States)

    Lie, H C; Quer, J

    2017-11-21

    In molecular dynamics, enhanced sampling methods enable the collection of better statistics of rare events from a reference or target distribution. We show that a large class of these methods is based on the idea of importance sampling from mathematical statistics. We illustrate this connection by comparing the Hartmann-Schütte method for rare event simulation (J. Stat. Mech. Theor. Exp. 2012, P11004) and the Valsson-Parrinello method of variationally enhanced sampling [Phys. Rev. Lett. 113, 090601 (2014)]. We use this connection in order to discuss how recent results from the Monte Carlo methods literature can guide the development of enhanced sampling methods.

  15. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    Science.gov (United States)

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  16. High-risk human papillomavirus detection in self-sampling compared to physician-taken smear in a responder population of the Dutch cervical screening: Results of the VERA study.

    Science.gov (United States)

    Ketelaars, P J W; Bosgraaf, R P; Siebers, A G; Massuger, L F A G; van der Linden, J C; Wauters, C A P; Rahamat-Langendoen, J C; van den Brule, A J C; IntHout, J; Melchers, W J G; Bekkers, R L M

    2017-08-01

    In 2017 the cervical cancer screening program in The Netherlands will be revised. Cervical smears will primarily be tested for the presence of high-risk human papillomavirus (hrHPV) instead of cytology, and vaginal self-sampling will be offered to non-responders. This includes a potential risk that part of the women who would otherwise opt for a cervical smear will wait for self-sampling. However, self-sampling for hrHPV in a responder population has never been studied yet. The aim of this study was to investigate the applicability and accuracy of self-sampling in detecting hrHPV in a screening responder population. A total of 2049 women, aged 30-60years, participating in the screening program in The Netherlands were included from April 2013 to May 2015. After they had their cervical smear taken, women self-collected a cervicovaginal sample with a brush-based device, the Evalyn Brush. Both the cervical smear and self-sample specimen were tested with the COBAS 4800 HPV platform. The hrHPV prevalence was 8.0% (95% CI 6.9-9.2) among the physician-taken samples, and 10.0% (95% CI 8.7-11.3) among the self-samples. There was 96.8% (95% CI 96.0-97.5) concordance of hrHPV prevalence between self-samples and physician-taken samples. Women in our study evaluated self-sampling as convenient (97.1%), user-friendly (98.5%), and 62.8% preferred self-sampling over a physician-taken sampling for the next screening round. In conclusion, self-sampling showed high concordance with physician-taken sampling for hrHPV detection in a responder screening population and highly acceptable to women. Implementation of HPV-self-sampling for the responder population as a primary screening tool may be considered. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Comparing the proteome of snap frozen, RNAlater preserved, and formalin-fixed paraffin-embedded human tissue samples

    DEFF Research Database (Denmark)

    Bennike, Tue Bjerg; Kastaniegaard, Kenneth; Padurariu, Simona

    2016-01-01

    Large biobanks exist worldwide containing formalin-fixed, paraffin-embedded samples and samples stored in RNAlater. However, the impact of tissue preservation on the result of a quantative proteome analysis remains poorly described.Human colon mucosal biopsies were extracted from the sigmoideum...

  18. Periodontal microbiota of Sardinian children: comparing 200-year-old samples to present-day ones

    Directory of Open Access Journals (Sweden)

    Germano Orrù

    2017-02-01

    Full Text Available Introduction: The microrganisms of the human oral cavity include more than 700 species or phenotypes of bacteria. Some “diseases of civilization” are strictly correlated to changes in the microbiome following the food revolution that occurred after WWII. For that reason, a precise recognition of the microbiome profile before and after this period should be useful to determine the health-compatible model of microbiome. The aim of this study was to compare the microbiome profiles (number of total cells, and pathogen types of dental samples obtained from two distinct groups of children, a 200-year-old retrieved one and a present one.Methods: Two different groups of samples have been studied. The first group was a set of 50 recent subgingival plaque samples obtained from children of age 2-8 years, 14 males and 36 females. They were enrolled by the Department of Dental Disease Prevention (University of Cagliari, in Sardinia, Italy during standard dental care procedures. None reported periodontal disease and none had been under antibiotic therapy during the previous 6 months. The second group was an old retrieved group that included 24 teeth from 6 different 6- to 8-year-old crania fragments; they were obtained from a 200-year-old charnel-house located in Villaputzu, a city close to Cagliari. Representative periodontal bacteria have been identified by a previously published real-time PCR procedure (Sokransky et al., 1998 in which P. gingivalis and T. forsythia (red complex, A. actinomycetemcomitans (green complex and F. nucleatum (orange complex were detected. In addition, the title of each pathogen was expressed as a percentage of the total bacteria (biofilm in the sample.Results and discussion: The profile of periodontal microbiomes, between recent/ancient samples showed a significant difference relative to Sokransky’s red complex bacteria (p < 0.05. In all analyzed periodontal strains, the pathogenic bacteria P. gingivalis and T. forsythia

  19. Reporting altered test results in hemolyzed samples: is the cure worse than the disease?

    Science.gov (United States)

    Lippi, Giuseppe; Cervellin, Gianfranco; Plebani, Mario

    2017-07-26

    The management of laboratory data in unsuitable (hemolyzed) samples remains an almost unresolved dilemma. Whether or not laboratory test results obtained by measuring unsuitable specimens should be made available to the clinicians has been the matter of fierce debates over the past decades. Recently, an intriguing alternative to suppressing test results and recollecting the specimen has been put forward, entailing the definition and implementation of specific algorithms that would finally allow reporting a preanalytically altered laboratory value within a specific comment about its uncertainty of measurement. This approach carries some advantages, namely the timely communication of potentially life-threatening laboratory values, but also some drawbacks. These especially include the challenging definition of validated performance specifications for hemolyzed samples, the need to producing reliable data with the lowest possible uncertainty, the short turnaround time for repeating most laboratory tests, the risk that the comments may be overlooked in short-stay and frequently overcrowded units (e.g. the emergency department), as well as the many clinical advantages of a direct communication with the physician in charge of the patient. Despite the debate remains open, we continue supporting the suggestion that suppressing data in unsuitable (hemolyzed) samples and promptly notifying the clinicians about the need to recollect the samples remains the most (clinically and analytically) safe practice.

  20. Membrane materials for storing biological samples intended for comparative nanotoxicological testing

    Science.gov (United States)

    Metelkin, A.; Kuznetsov, D.; Kolesnikov, E.; Chuprunov, K.; Kondakov, S.; Osipov, A.; Samsonova, J.

    2015-11-01

    The study is aimed at identifying the samples of most promising membrane materials for storing dry specimens of biological fluids (Dried Blood Spots, DBS technology). Existing sampling systems using cellulose fiber filter paper have a number of drawbacks such as uneven distribution of the sample spot, dependence of the spot spreading area on the individual biosample properties, incomplete washing-off of the sample due to partially inconvertible sorption of blood components on cellulose fibers, etc. Samples of membrane materials based on cellulose, polymers and glass fiber with applied biosamples were studied using methods of scanning electron microscopy, FT-IR spectroscopy and surface-wetting measurement. It was discovered that cellulose-based membrane materials sorb components of biological fluids inside their structure, while membranes based on glass fiber display almost no interaction with the samples and biological fluid components dry to films in the membrane pores between the structural fibers. This characteristic, together with the fact that membrane materials based on glass fiber possess sufficient strength, high wetting properties and good storage capacity, attests them as promising material for dry samples of biological fluids storage systems.

  1. Membrane materials for storing biological samples intended for comparative nanotoxicological testing

    International Nuclear Information System (INIS)

    Metelkin, A; Kuznetsov, D; Kolesnikov, E; Chuprunov, K; Kondakov, S; Osipov, A; Samsonova, J

    2015-01-01

    The study is aimed at identifying the samples of most promising membrane materials for storing dry specimens of biological fluids (Dried Blood Spots, DBS technology). Existing sampling systems using cellulose fiber filter paper have a number of drawbacks such as uneven distribution of the sample spot, dependence of the spot spreading area on the individual biosample properties, incomplete washing-off of the sample due to partially inconvertible sorption of blood components on cellulose fibers, etc. Samples of membrane materials based on cellulose, polymers and glass fiber with applied biosamples were studied using methods of scanning electron microscopy, FT-IR spectroscopy and surface-wetting measurement. It was discovered that cellulose-based membrane materials sorb components of biological fluids inside their structure, while membranes based on glass fiber display almost no interaction with the samples and biological fluid components dry to films in the membrane pores between the structural fibers. This characteristic, together with the fact that membrane materials based on glass fiber possess sufficient strength, high wetting properties and good storage capacity, attests them as promising material for dry samples of biological fluids storage systems. (paper)

  2. Groundwater-quality data in 12 GAMA study units: Results from the 2006–10 initial sampling period and the 2008–13 trend sampling period, California GAMA Priority Basin Project

    Science.gov (United States)

    Mathany, Timothy M.

    2017-03-09

    constituents (volatile organic compounds, pesticides, and pesticide degradates), constituents of special interest (perchlorate and 1,2,3-trichloropropane), and natural inorganic constituents (nutrients, major and minor ions, and trace elements). Isotopic tracers (tritium, carbon-14, and stable isotopes of hydrogen and oxygen in water) also were measured to help identify processes affecting groundwater quality and the sources and ages of the sampled groundwater. More than 200 constituents and water-quality indicators were measured during the trend sampling period.Quality-control samples (blanks, replicates, matrix-spikes, and surrogate compounds) were collected at about one-third of the trend sites, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. On the basis of detections in laboratory and field blank samples collected by GAMA-PBP study units, including the 12 study units presented here, reporting levels for some groundwater results were adjusted in this report. Differences between replicate samples were mostly within acceptable ranges, indicating low variability in analytical results. Matrix-spike recoveries were largely within the acceptable range (70 to 130 percent).This study did not attempt to evaluate the quality of water delivered to consumers. After withdrawal, groundwater used for drinking water typically is treated, disinfected, and blended with other waters to achieve acceptable water quality. The comparison benchmarks used in this report apply to treated water that is served to the consumer, not to untreated groundwater. To provide some context for the results, however, concentrations of constituents measured in these groundwater samples were compared with benchmarks established by the U.S. Environmental Protection Agency and the State of California. Comparisons between data collected for this study and benchmarks for drinking water are for illustrative purposes only and are not indicative of compliance

  3. Analysis of genomic alterations in neuroblastoma by multiplex ligation-dependent probe amplification and array comparative genomic hybridization: a comparison of results.

    Science.gov (United States)

    Combaret, Valérie; Iacono, Isabelle; Bréjon, Stéphanie; Schleiermacher, Gudrun; Pierron, Gäelle; Couturier, Jérôme; Bergeron, Christophe; Blay, Jean-Yves

    2012-12-01

    In cases of neuroblastoma, recurring genetic alterations--losses of the 1p, 3p, 4p, and 11q and/or gains of 1q, 2p, and 17q chromosome arms--are currently used to define the therapeutic strategy in therapeutic protocols for low- and intermediate-risk patients. Different genome-wide analysis techniques, such as array comparative genomic hybridization (aCGH) or multiplex ligation-dependent probe amplification (MLPA), have been suggested for detecting chromosome segmental abnormalities. In this study, we compared the results of the two technologies in the analyses of the DNA of tumor samples from 91 neuroblastoma patients. Similar results were obtained with the two techniques for 75 samples (82%). In five cases (5.5%), the MLPA results were not interpretable. Discrepancies between the aCGH and MLPA results were observed in 11 cases (12%). Among the discrepancies, a 18q21.2-qter gain and 16p11.2 and 11q14.1-q14.3 losses were detected only by aCGH. The MLPA results showed that the 7p, 7q, and 14q chromosome arms were affected in six cases, while in two cases, 2p and 17q gains were observed; these results were confirmed by neither aCGH nor fluorescence in situ hybridization (FISH) analysis. Because of the higher sensitivity and specificity of genome-wide information, reasonable cost, and shorter time of aCGH analysis, we recommend the aCGH procedure for the analysis of genomic alterations in neuroblastoma. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Analysis and radiological assessment of survey results and samples from the beaches around Sellafield

    International Nuclear Information System (INIS)

    Webb, G.A.M.; Fry, F.A.

    1983-12-01

    After radioactive sea debris had been found on beaches near the BNFL, Sellafield, plant, NRPB was asked by the Department of the Environment to analyse some of the samples collected and to assess the radiological hazard to members of the public. A report is presented containing an analysis of survey reports for the period 19 November - 4 December 1983 and preliminary results of the analysis of all samples received, together with the Board's recommendations. (author)

  5. Analysis results of PAVE sampling of groundwaters from open boreholes OL-KR2, OL-KR7, OL-KR13 and OL-KR15 at Olkiluoto, Eurajoki, in 2004

    Energy Technology Data Exchange (ETDEWEB)

    Hirvonen, H. [Teollisuuden Voima Oyj, Eurajoki (Finland); Hatanpaa, E. [lnsinoeoeritoimisto Paavo Ristola Oy, Hollola (Finland)

    2005-12-15

    Four groundwater samples were collected at Olkiluoto from open boreholes OL-KR2, OL-KR7, OL-KR13 and OL-KR15 with pressurised water sampling equipment (PAVE) between summer 2004 and the beginning of 2005. The aim of the ground water sampling was to get information for the basis of the monitoring program during ONKALO construction. Sampling sections were mainly chosen so that the results of the chemical analyses from earlier studies could be used for comparison. This study is a part of Olkiluoto's monitoring programme (OMO). This study presents the sampling methods and the results of the laboratory analyses of groundwater samples from the open boreholes OL-KR2/328.5-330.5 m, OL-KR7/275.5- 289.5 m, OL-KR13/362-365 m and OL-KR15/241-245 m. The analytical results of the groundwater samplings are compared to earlier analytical results. According to Davis and De Wiest's ( 1967) classification, all ground water samples represent the borehole water type Na-Cl. All ground water samples were brackish ( 1000 mg/L < TDS < 1 0000 mg/L) according to Davis's ( 1964) TDS classification. Comparison of analytical results of the samples to earlier results shows that some changes have occurred between samplings. Other parameters, with couple of particular exceptions, have a downward trend, but bicarbonate concentration has increased in all boreholes. Concentrations of main parameters have changed most in OL-KR7 and OL-KR13 waters. Gas analyses results have not changed significantly, but increased carbon dioxide concentration is noticed in gas analysis results also. (orig.)

  6. Comparisons of methods for generating conditional Poisson samples and Sampford samples

    OpenAIRE

    Grafström, Anton

    2005-01-01

    Methods for conditional Poisson sampling (CP-sampling) and Sampford sampling are compared and the focus is on the efficiency of the methods. The efficiency is investigated by simulation in different sampling situations. It was of interest to compare methods since new methods for both CP-sampling and Sampford sampling were introduced by Bondesson, Traat & Lundqvist in 2004. The new methods are acceptance rejection methods that use the efficient Pareto sampling method. They are found to be ...

  7. Comparative Study of Radon Concentration with Two Techniques and Elemental Analysis in Drinking Water Samples of the Jammu District, Jammu and Kashmir, India.

    Science.gov (United States)

    Kumar, Ajay; Kaur, Manpreet; Mehra, Rohit; Sharma, Dinesh Kumar; Mishra, Rosaline

    2017-10-01

    The level of radon concentration has been assessed using the Advanced SMART RnDuo technique in 30 drinking water samples from Jammu district, Jammu and Kashmir, India. The water samples were collected from wells, hand pumps, submersible pumps, and stored waters. The randomly obtained 14 values of radon concentration in water sources using the SMART RnDuo technique have been compared and cross checked by a RAD7 device. A good positive correlation (R = 0.88) has been observed between the two techniques. The overall value of radon concentration in various water sources has ranged from 2.45 to 18.43 Bq L, with a mean value of 8.24 ± 4.04 Bq L, and it agreed well with the recommended limit suggested by the European Commission and UNSCEAR. However, the higher activity of mean radon concentration was found in groundwater drawn from well, hand and submersible pumps as compared to stored water. The total annual effective dose due to radon inhalation and ingestion ranged from 6.69 to 50.31 μSv y with a mean value of 22.48 ± 11.03 μSv y. The total annual effective dose was found to lie within the safe limit (100 μSv y) suggested by WHO. Heavy metal analysis was also carried out in various water sources by using an atomic absorption spectrophotometer (AAS), and the highest value of heavy metals was found mostly in groundwater samples. The obtained results were compared with Indian and International organizations like WHO and the EU Council. Among all the samples, the elemental analysis is not on the exceeding side of the permissible limit.

  8. Strategies for achieving high sequencing accuracy for low diversity samples and avoiding sample bleeding using illumina platform.

    Science.gov (United States)

    Mitra, Abhishek; Skrzypczak, Magdalena; Ginalski, Krzysztof; Rowicka, Maga

    2015-01-01

    Sequencing microRNA, reduced representation sequencing, Hi-C technology and any method requiring the use of in-house barcodes result in sequencing libraries with low initial sequence diversity. Sequencing such data on the Illumina platform typically produces low quality data due to the limitations of the Illumina cluster calling algorithm. Moreover, even in the case of diverse samples, these limitations are causing substantial inaccuracies in multiplexed sample assignment (sample bleeding). Such inaccuracies are unacceptable in clinical applications, and in some other fields (e.g. detection of rare variants). Here, we discuss how both problems with quality of low-diversity samples and sample bleeding are caused by incorrect detection of clusters on the flowcell during initial sequencing cycles. We propose simple software modifications (Long Template Protocol) that overcome this problem. We present experimental results showing that our Long Template Protocol remarkably increases data quality for low diversity samples, as compared with the standard analysis protocol; it also substantially reduces sample bleeding for all samples. For comprehensiveness, we also discuss and compare experimental results from alternative approaches to sequencing low diversity samples. First, we discuss how the low diversity problem, if caused by barcodes, can be avoided altogether at the barcode design stage. Second and third, we present modified guidelines, which are more stringent than the manufacturer's, for mixing low diversity samples with diverse samples and lowering cluster density, which in our experience consistently produces high quality data from low diversity samples. Fourth and fifth, we present rescue strategies that can be applied when sequencing results in low quality data and when there is no more biological material available. In such cases, we propose that the flowcell be re-hybridized and sequenced again using our Long Template Protocol. Alternatively, we discuss how

  9. Strategies for achieving high sequencing accuracy for low diversity samples and avoiding sample bleeding using illumina platform.

    Directory of Open Access Journals (Sweden)

    Abhishek Mitra

    Full Text Available Sequencing microRNA, reduced representation sequencing, Hi-C technology and any method requiring the use of in-house barcodes result in sequencing libraries with low initial sequence diversity. Sequencing such data on the Illumina platform typically produces low quality data due to the limitations of the Illumina cluster calling algorithm. Moreover, even in the case of diverse samples, these limitations are causing substantial inaccuracies in multiplexed sample assignment (sample bleeding. Such inaccuracies are unacceptable in clinical applications, and in some other fields (e.g. detection of rare variants. Here, we discuss how both problems with quality of low-diversity samples and sample bleeding are caused by incorrect detection of clusters on the flowcell during initial sequencing cycles. We propose simple software modifications (Long Template Protocol that overcome this problem. We present experimental results showing that our Long Template Protocol remarkably increases data quality for low diversity samples, as compared with the standard analysis protocol; it also substantially reduces sample bleeding for all samples. For comprehensiveness, we also discuss and compare experimental results from alternative approaches to sequencing low diversity samples. First, we discuss how the low diversity problem, if caused by barcodes, can be avoided altogether at the barcode design stage. Second and third, we present modified guidelines, which are more stringent than the manufacturer's, for mixing low diversity samples with diverse samples and lowering cluster density, which in our experience consistently produces high quality data from low diversity samples. Fourth and fifth, we present rescue strategies that can be applied when sequencing results in low quality data and when there is no more biological material available. In such cases, we propose that the flowcell be re-hybridized and sequenced again using our Long Template Protocol. Alternatively

  10. Variation in the human lymphocyte sister chromatid exchange frequency as a function of time: results of daily and twice-weekly sampling

    Energy Technology Data Exchange (ETDEWEB)

    Tucker, J.D.; Christensen, M.L.; Strout, C.L.; McGee, K.A.; Carrano, A.V.

    1987-01-01

    The variation in lymphocyte sister chromatid exchange (SCE) frequency was investigated in healthy nonsmokers who were not taking any medication. Two separate studies were undertaken. In the first, blood was drawn from four women twice a week for 8 weeks. These donors recorded the onset and termination of menstruation and times of illness. In the second study, blood was obtained from two women and two men for 5 consecutive days on two separate occasions initiated 14 days apart. Analysis of the mean SCE frequencies in each study indicated that significant temporal variation occurred in each donor, and that more variation occurred in the longer study. Some of the variation was found to be associated with the menstrual cycle. In the daily study, most of the variation appeared to be random, but occasional day-to-day changes occurred that were greater than those expected by chance. To determine how well a single SCE sample estimated the pooled mean for each donor in each study, the authors calculated the number of samples that encompassed that donor's pooled mean within 1 or more standard errors. For both studies, about 75% of the samples encompassed the pooled mean within 2 standard errors. An analysis of high-frequency cells (HFCs) was also undertaken. The results for each study indicate that the proportion of HFCs, compared with the use of Fisher's Exact test, is significantly more constant than the means, which were compared by using the t-test. These results coupled with our previous work suggest that HFC analysis may be the method of choice when analyzing data from human population studies.

  11. Comparing three cohorts of MSM sampled via sex parties, bars/clubs, and Craigslist.org: implications for researchers and providers.

    Science.gov (United States)

    Grov, Christian; Rendina, H Jonathon; Parsons, Jeffrey T

    2014-08-01

    With limited exceptions, few studies have systematically reported on psychosocial and demographic characteristic differences in samples of men who have sex with men (MSM) based on where they were recruited. This study compared three sexually active cohorts of MSM recruited via Craigslist.org (recruited via modified time-space sampling), gay bars and clubs (recruited via time-space sampling), and private sex parties (identified via passive recruitment and listserves), finding mixed results with regard to differences in demographic characteristics, STI history, and psychosocial measures. Men recruited from sex parties were significantly older, reported more symptoms of sexual compulsivity, more likely to be HIV-positive, more likely to report a history of STIs, and more likely to self-identify as a barebacker, than men recruited from the other two venues. In contrast, men from Craigslist.org reported the lowest levels of attachment to the gay and bisexual community and were the least likely to self-identify as gay. Men from bars and clubs were significantly younger, and were more likely to report use of hallucinogens and crack or cocaine. Our findings highlight that the venues in which MSM are recruited have meaningful consequences in terms of the types of individuals who are reached.

  12. Nationwide Inpatient Sample and National Surgical Quality Improvement Program give different results in hip fracture studies.

    Science.gov (United States)

    Bohl, Daniel D; Basques, Bryce A; Golinvaux, Nicholas S; Baumgaertner, Michael R; Grauer, Jonathan N

    2014-06-01

    National databases are being used with increasing frequency to conduct orthopaedic research. However, there are important differences in these databases, which could result in different answers to similar questions; this important potential limitation pertaining to database research in orthopaedic surgery has not been adequately explored. The purpose of this study was to explore the interdatabase reliability of two commonly used national databases, the Nationwide Inpatient Sample (NIS) and the National Surgical Quality Improvement Program (NSQIP), in terms of (1) demographics; (2) comorbidities; and (3) adverse events. In addition, using the NSQIP database, we identified (4) adverse events that had a higher prevalence after rather than before discharge, which has important implications for interpretation of studies conducted in the NIS. A retrospective cohort study of patients undergoing operative stabilization of transcervical and intertrochanteric hip fractures during 2009 to 2011 was performed in the NIS and NSQIP. Totals of 122,712 and 5021 patients were included from the NIS and NSQIP, respectively. Age, sex, fracture type, and lengths of stay were compared. Comorbidities common to both databases were compared in terms of more or less than twofold difference between the two databases. Similar comparisons were made for adverse events. Finally, adverse events that had a greater postdischarge prevalence were identified from the NSQIP database. Tests for statistical difference were thought to be of little value given the large sample size and the resulting fact that statistical differences would have been identified even for small, clinically inconsequential differences resulting from the associated high power. Because it is of greater clinical importance to focus on the magnitude of differences, the databases were compared by absolute differences. Demographics and hospital lengths of stay were not different between the two databases. In terms of comorbidities

  13. Compilation of PRF Canyon Floor Pan Sample Analysis Results

    Energy Technology Data Exchange (ETDEWEB)

    Pool, Karl N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Minette, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wahl, Jon H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Greenwood, Lawrence R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Coffey, Deborah S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Scheele, Randall D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sinkov, Sergey I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Soderquist, Chuck Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fiskum, Sandra K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Brown, Garrett N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clark, Richard A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-30

    On September 28, 2015, debris collected from the PRF (236-Z) canyon floor, Pan J, was observed to exhibit chemical reaction. The material had been transferred from the floor pan to a collection tray inside the canyon the previous Friday. Work in the canyon was stopped to allow Industrial Hygiene to perform monitoring of the material reaction. Canyon floor debris that had been sealed out was sequestered at the facility, a recovery plan was developed, and drum inspections were initiated to verify no additional reactions had occurred. On October 13, in-process drums containing other Pan J material were inspected and showed some indication of chemical reaction, limited to discoloration and degradation of inner plastic bags. All Pan J material was sealed back into the canyon and returned to collection trays. Based on the high airborne levels in the canyon during physical debris removal, ETGS (Encapsulation Technology Glycerin Solution) was used as a fogging/lock-down agent. On October 15, subject matter experts confirmed a reaction had occurred between nitrates (both Plutonium Nitrate and Aluminum Nitrate Nonahydrate (ANN) are present) in the Pan J material and the ETGS fixative used to lower airborne radioactivity levels during debris removal. Management stopped the use of fogging/lock-down agents containing glycerin on bulk materials, declared a Management Concern, and initiated the Potential Inadequacy in the Safety Analysis determination process. Additional drum inspections and laboratory analysis of both reacted and unreacted material are planned. This report compiles the results of many different sample analyses conducted by the Pacific Northwest National Laboratory on samples collected from the Plutonium Reclamation Facility (PRF) floor pans by the CH2MHill’s Plateau Remediation Company (CHPRC). Revision 1 added Appendix G that reports the results of the Gas Generation Rate and methodology. The scope of analyses requested by CHPRC includes the determination of

  14. Comparative analysis of metal samples

    International Nuclear Information System (INIS)

    Lopez M, J.; Ramirez T, J.J.; Sandoval J, A.R.; Villasenor S, P.; Aspiazu F, J.A.

    2001-01-01

    Metal wastes were analysed to establish its origin with respect to a set of pieces. The elemental analysis was realized using the PIXE technique (Proton induced X-ray emission). Results are presented. (Author)

  15. The Lyα reference sample. I. Survey outline and first results for Markarian 259

    International Nuclear Information System (INIS)

    Östlin, Göran; Hayes, Matthew; Duval, Florent; Sandberg, Andreas; Rivera-Thorsen, Thøger; Marquart, Thomas; Adamo, Angela; Melinder, Jens; Guaita, Lucia; Micheva, Genoveva; Orlitová, Ivana; Atek, Hakim; Cannon, John M.; Pardy, Stephen A.; Gruyters, Pieter; Herenz, Edmund Christian; Kunth, Daniel; Laursen, Peter; Mas-Hesse, J. Miguel; Otí-Floranes, Héctor

    2014-01-01

    The Lyα Reference Sample (LARS) is a substantial program with the Hubble Space Telescope (HST) that provides a sample of local universe laboratory galaxies in which to study the detailed astrophysics of the visibility and strength of the Lyαline of neutral hydrogen. Lyα is the dominant spectral line in use for characterizing high-redshift (z) galaxies. This paper presents an overview of the survey, its selection function, and HST imaging observations. The sample was selected from the combined GALEX+Sloan Digital Sky Survey catalog at z = 0.028-0.19, in order to allow Lyα to be captured with combinations of long-pass filters in the Solar Blind Channel (SBC) of the Advanced Camera for Surveys (ACS) onboard HST. In addition, LARS utilizes Hα and Hβ narrowband and u, b, i broadband imaging with ACS and the Wide Field Camera 3 (WFC3). In order to study galaxies in which large numbers of Lyα photons are produced (whether or not they escape), we demanded an Hα equivalent width W(Hα) ≥100 Å. The final sample of 14 galaxies covers far-UV (FUV, λ ∼ 1500 Å) luminosities that overlap with those of high-z Lyα emitters (LAEs) and Lyman break galaxies (LBGs), making LARS a valid comparison sample. We present the reduction steps used to obtain the Lyα images, including our LARS eXtraction software (LaXs), which utilizes pixel-by-pixel spectral synthesis fitting of the energy distribution to determine and subtract the continuum at Lyα. We demonstrate that the use of SBC long-pass-filter combinations increase the signal-to-noise ratio by an order of magnitude compared to the nominal Lyα filter available in SBC. To exemplify the science potential of LARS, we also present some first results for a single galaxy, Mrk 259 (LARS #1). This irregular galaxy shows bright and extended (indicative of resonance scattering) but strongly asymmetric Lyα emission. Spectroscopy from the Cosmic Origins Spectrograph on board HST centered on the brightest UV knot shows a moderate

  16. The Lyα reference sample. I. Survey outline and first results for Markarian 259

    Energy Technology Data Exchange (ETDEWEB)

    Östlin, Göran; Hayes, Matthew; Duval, Florent; Sandberg, Andreas; Rivera-Thorsen, Thøger; Marquart, Thomas; Adamo, Angela; Melinder, Jens; Guaita, Lucia; Micheva, Genoveva [Department of Astronomy, Stockholm University, Oscar Klein Centre, AlbaNova, Stockholm SE-106 91 (Sweden); Orlitová, Ivana [Observatoire de Genève, Université de Genève, Chemin des Maillettes 51, 1290 Versoix (Switzerland); Atek, Hakim [Laboratoire d' Astrophysique, Ecole Polytechnique Fédérale de Lausanne, Observatoire de Sauverny, CH-1290 Versoix (Switzerland); Cannon, John M.; Pardy, Stephen A. [Department of Physics and Astronomy, Macalester College, 1600 Grand Avenue, Saint Paul, MN 55105 (United States); Gruyters, Pieter [Department of Physics and Astronomy, Division of Astronomy and Space Physics, Uppsala University, Box 516, 75120 Uppsala (Sweden); Herenz, Edmund Christian [Leibniz-Institute for Astrophysics Potsdam (AIP), innoFSPEC, An der Sternwarte 16, D-14482 Potsdam (Germany); Kunth, Daniel [Institut d' Astrophysique Paris, 98bis Bd Arago, F-75014 Paris (France); Laursen, Peter [Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, DK-2100 Copenhagen (Denmark); Mas-Hesse, J. Miguel [Centro de Astrobiologa (CSIC-INTA), Departamento de Astrofsica, POB 78, E-28691, Villanueva de la Cañada (Spain); Otí-Floranes, Héctor [Instituto de Astronoma, Universidad Nacional Autnoma de Mxico, Apdo. Postal 106, Ensenada B. C. 22800 (Mexico); and others

    2014-12-10

    The Lyα Reference Sample (LARS) is a substantial program with the Hubble Space Telescope (HST) that provides a sample of local universe laboratory galaxies in which to study the detailed astrophysics of the visibility and strength of the Lyαline of neutral hydrogen. Lyα is the dominant spectral line in use for characterizing high-redshift (z) galaxies. This paper presents an overview of the survey, its selection function, and HST imaging observations. The sample was selected from the combined GALEX+Sloan Digital Sky Survey catalog at z = 0.028-0.19, in order to allow Lyα to be captured with combinations of long-pass filters in the Solar Blind Channel (SBC) of the Advanced Camera for Surveys (ACS) onboard HST. In addition, LARS utilizes Hα and Hβ narrowband and u, b, i broadband imaging with ACS and the Wide Field Camera 3 (WFC3). In order to study galaxies in which large numbers of Lyα photons are produced (whether or not they escape), we demanded an Hα equivalent width W(Hα) ≥100 Å. The final sample of 14 galaxies covers far-UV (FUV, λ ∼ 1500 Å) luminosities that overlap with those of high-z Lyα emitters (LAEs) and Lyman break galaxies (LBGs), making LARS a valid comparison sample. We present the reduction steps used to obtain the Lyα images, including our LARS eXtraction software (LaXs), which utilizes pixel-by-pixel spectral synthesis fitting of the energy distribution to determine and subtract the continuum at Lyα. We demonstrate that the use of SBC long-pass-filter combinations increase the signal-to-noise ratio by an order of magnitude compared to the nominal Lyα filter available in SBC. To exemplify the science potential of LARS, we also present some first results for a single galaxy, Mrk 259 (LARS #1). This irregular galaxy shows bright and extended (indicative of resonance scattering) but strongly asymmetric Lyα emission. Spectroscopy from the Cosmic Origins Spectrograph on board HST centered on the brightest UV knot shows a moderate

  17. Comparative study of modern extraction techniques for the determination of environmental samples (M14)

    International Nuclear Information System (INIS)

    Gfrerer, M.; Lankmayr, E.

    2002-01-01

    Full text: The aim of any extraction method in analytical chemistry is, to effectively separate the analytes from the matrix. The whole step should be fast and quantitative with minimal solvent and time required. The classical Soxhlet extraction usually requires large volumes (up to 200 ml) of solvent to be refluxed through the solid samples for several hours. Therefore, in the last decades, alternatives for this extraction method have been presented and investigated such as ultrasonic extraction (UE), supercritical fluid extraction (SFE), accelerated solvent extraction (ASE), microwave-assisted extraction (MAE) and fluidized-bed extraction (FBE). The actual choice for analytical application is frequently the initial capital cost, operating costs, simplicity of operation, amount of organic solvent required and sample throughput. Since sample preparation is a critical step in the analytical cycle, special care has to be taken for an accurate choice and optimization of extraction techniques and clean-up procedures. Therefore, MAE and FBE were investigated for their influential extraction parameters and these parameters were optimized for the extraction of organochlorine biocides, polychlorinated biphenyls and polycyclic aromatic hydrocarbons from environmental matrices like soil, sediment and sewage sludge. The extraction yields were compared with those obtained by Soxhlet extraction performed following DIN-methods. Finally, the optimized modern methods were validated by systematic experiments with certified reference materials. Refs. 3 (author)

  18. Status report on the Zagreb Radiocarbon Laboratory – AMS and LSC results of VIRI intercomparison samples

    International Nuclear Information System (INIS)

    Sironić, Andreja; Krajcar Bronić, Ines; Horvatinčić, Nada; Barešić, Jadranka; Obelić, Bogomil; Felja, Igor

    2013-01-01

    A new line for preparation of the graphite samples for 14 C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. 14 C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 ± 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  19. Results For The Third Quarter 2013 Tank 50 WAC Slurry Sample

    Energy Technology Data Exchange (ETDEWEB)

    Bannochie, Christopher J.

    2013-11-26

    This report details the chemical and radionuclide contaminant results for the characterization of the 2013 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

  20. Sample exchange/evaluation (SEE) report - Phase III

    International Nuclear Information System (INIS)

    Winters, W.I.

    1996-01-01

    This report describes the results from Phase III of the Sample Exchange Evaluation (SEE) program. The SEE program is used to compare analytical laboratory performance on samples from the Hanford Site's high level waste tanks

  1. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison.

    Science.gov (United States)

    Jonker, Michiel T O; van der Heijden, Stephan A; Adelman, Dave; Apell, Jennifer N; Burgess, Robert M; Choi, Yongju; Fernandez, Loretta A; Flavetta, Geanna M; Ghosh, Upal; Gschwend, Philip M; Hale, Sarah E; Jalalizadeh, Mehregan; Khairy, Mohammed; Lampi, Mark A; Lao, Wenjian; Lohmann, Rainer; Lydy, Michael J; Maruya, Keith A; Nutile, Samuel A; Oen, Amy M P; Rakowska, Magdalena I; Reible, Danny; Rusina, Tatsiana P; Smedes, Foppe; Wu, Yanwen

    2018-03-20

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical guidance for standardized passive sampling, and advance the use of passive sampling in regulatory decision making by increasing confidence in the use of the technique. The study was performed by a consortium of 11 laboratories and included experiments with 14 passive sampling formats on 3 sediments for 25 target chemicals (PAHs and PCBs). The resulting overall interlaboratory variability was large (a factor of ∼10), but standardization of methods halved this variability. The remaining variability was primarily due to factors not related to passive sampling itself, i.e., sediment heterogeneity and analytical chemistry. Excluding the latter source of variability, by performing all analyses in one laboratory, showed that passive sampling results can have a high precision and a very low intermethod variability (sampling, irrespective of the specific method used, is fit for implementation in risk assessment and management of contaminated sediments, provided that method setup and performance, as well as chemical analyses are quality-controlled.

  2. Men who have sex with men in Great Britain: comparing methods and estimates from probability and convenience sample surveys.

    Science.gov (United States)

    Prah, Philip; Hickson, Ford; Bonell, Chris; McDaid, Lisa M; Johnson, Anne M; Wayal, Sonali; Clifton, Soazig; Sonnenberg, Pam; Nardone, Anthony; Erens, Bob; Copas, Andrew J; Riddell, Julie; Weatherburn, Peter; Mercer, Catherine H

    2016-09-01

    To examine sociodemographic and behavioural differences between men who have sex with men (MSM) participating in recent UK convenience surveys and a national probability sample survey. We compared 148 MSM aged 18-64 years interviewed for Britain's third National Survey of Sexual Attitudes and Lifestyles (Natsal-3) undertaken in 2010-2012, with men in the same age range participating in contemporaneous convenience surveys of MSM: 15 500 British resident men in the European MSM Internet Survey (EMIS); 797 in the London Gay Men's Sexual Health Survey; and 1234 in Scotland's Gay Men's Sexual Health Survey. Analyses compared men reporting at least one male sexual partner (past year) on similarly worded questions and multivariable analyses accounted for sociodemographic differences between the surveys. MSM in convenience surveys were younger and better educated than MSM in Natsal-3, and a larger proportion identified as gay (85%-95% vs 62%). Partner numbers were higher and same-sex anal sex more common in convenience surveys. Unprotected anal intercourse was more commonly reported in EMIS. Compared with Natsal-3, MSM in convenience surveys were more likely to report gonorrhoea diagnoses and HIV testing (both past year). Differences between the samples were reduced when restricting analysis to gay-identifying MSM. National probability surveys better reflect the population of MSM but are limited by their smaller samples of MSM. Convenience surveys recruit larger samples of MSM but tend to over-represent MSM identifying as gay and reporting more sexual risk behaviours. Because both sampling strategies have strengths and weaknesses, methods are needed to triangulate data from probability and convenience surveys. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. The economic impact of poor sample quality in clinical chemistry laboratories: results from a global survey.

    Science.gov (United States)

    Erdal, Erik P; Mitra, Debanjali; Khangulov, Victor S; Church, Stephen; Plokhoy, Elizabeth

    2017-03-01

    Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.

  4. Nursing Child Assessment Satellite Training Parent-Child Interaction Scales: Comparing American and Canadian Normative and High-Risk Samples.

    Science.gov (United States)

    Letourneau, Nicole L; Tryphonopoulos, Panagiota D; Novick, Jason; Hart, J Martha; Giesbrecht, Gerald; Oxford, Monica L

    Many nurses rely on the American Nursing Child Assessment Satellite Training (NCAST) Parent-Child Interaction (PCI) Teaching and Feeding Scales to identify and target interventions for families affected by severe/chronic stressors (e.g. postpartum depression (PPD), intimate partner violence (IPV), low-income). However, the NCAST Database that provides normative data for comparisons may not apply to Canadian families. The purpose of this study was to compare NCAST PCI scores in Canadian and American samples and to assess the reliability of the NCAST PCI Scales in Canadian samples. This secondary analysis employed independent samples t-tests (p parent-child relationships and ultimately child development. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  5. Comparative data compression techniques and multi-compression results

    International Nuclear Information System (INIS)

    Hasan, M R; Ibrahimy, M I; Motakabber, S M A; Ferdaus, M M; Khan, M N H

    2013-01-01

    Data compression is very necessary in business data processing, because of the cost savings that it offers and the large volume of data manipulated in many business applications. It is a method or system for transmitting a digital image (i.e., an array of pixels) from a digital data source to a digital data receiver. More the size of the data be smaller, it provides better transmission speed and saves time. In this communication, we always want to transmit data efficiently and noise freely. This paper will provide some compression techniques for lossless text type data compression and comparative result of multiple and single compression, that will help to find out better compression output and to develop compression algorithms

  6. Human bloodstains on bone artefacts: an SEM intra- and inter-sample comparative study using ratite bird tibiotarsus.

    Science.gov (United States)

    Hortolà, Policarp

    2016-11-01

    Apart from their forensic significance in crime investigation, human bloodstains have an anthropological interest due to their occurrence on certain traditional weapons and ritual objects. Previously, a guiding study of erythrocytes in experimental samples including domestic sheep (Ovis aries) tibia was carried out using a scanning electron microscope (SEM). Here, a comparative SEM study to reveal the potential differences in bloodstain surface morphology as a function of intra-sample (smear region) and inter-sample (individual smear, smearing mechanism, bone origin) parameters is reported. A fragment of emu (Dromaius novaehollandiae) tibiotarsus was smeared with an adult man's peripheral blood. After air-drying and storing indoors, the boundary and neighbouring inner areas of the three individual bloodstains obtained were examined via secondary electrons in a variable-pressure SEM working in low-vacuum mode. As a whole, desiccation microcracks were present, the limits between the smear and the substrate appeared poorly defined, and no erythrocyte negative replicas were observed in the examined areas. In addition, a putative fibrin network, more or less embedded in the dried plasma matrix, was observed in the smears' boundary. Regarding the smear region in sliding smears, the periphery and boundary revealed to be different, while the head and tail were similar. Considering individual sliding smears, they had similar characteristics. Relating to the smear region as a function of the smearing mechanism, the periphery was different whether sliding or touching, while the boundary was similar in sliding and touching smears. Concerning the smear region as a function of the bone origin, the periphery revealed to be similar in both ratite and mammalian bone, while the boundary did different in ratite and mammalian bone. The results of this study show that SEM examination can be used fruitfully to detect bloodstains on ratite bone. Combined with previous SEM results in

  7. ANALYTICAL RESULTS OF MOX COLEMANITE CONCRETE SAMPLES POURED AUGUST 29, 2012

    Energy Technology Data Exchange (ETDEWEB)

    Best, D.; Cozzi, A.; Reigel, M.

    2012-12-20

    The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. Samples poured 8/29/12 were received on 9/20/2012 and analyzed. The average total density of each of the samples measured by the ASTM method C 642 was within the lower bound of 1.88 g/cm{sup 3}. The average partial hydrogen density of samples 8.6.1, 8.7.1, and 8.5.3 as measured using method ASTM E 1311 met the lower bound of 6.04E-02 g/cm{sup 3}. The average measured partial boron density of each sample met the lower bound of 1.65E-01 g/cm{sup 3} measured by the ASTM C 1301 method. The average partial hydrogen density of samples 8.5.1, 8.6.3, and 8.7.3 did not meet the lower bound. The samples, as received, were not wrapped in a moist towel as previous samples and appeared to be somewhat drier. This may explain the lower hydrogen partial density with respect to previous samples.

  8. Do women who choose to become surrogate mothers have different psychological profiles compared to a normative female sample?

    Science.gov (United States)

    Pizitz, Todd D; McCullaugh, Joseph; Rabin, Alexa

    2013-03-01

    Surrogate mothers are routinely assessed for their suitability to function in the role of surrogacy. Such assessments often include psychological testing including the Minnesota multiphasic personality inventory-revised (MMPI-2). There has been a paucity of research detailing the personality structures of these women, especially with the MMPI-2. The current study examined the validity and clinical profiles of surrogate mothers (N=43) compared to a non-patient, normative reference sample of women (N=40) using their MMPI-2 results. This study examined between group differences among the 68 scales of the MMPI-2. Independent-sample t-tests were conducted for each of the scales, with those violating homogeneity of variance assessed with a non-parametric, Mann-Whitney U test. The findings demonstrated that surrogate mothers produce profiles with lower values than normative samples across several MMPI-2 scales. For this unique group, elevations were observed on scales that assess profile validity, views on traditional gender roles, repression, ego strength, social obligation and duties, and contained hostility, relative to the normative group. The findings provide an initial examination of the profiles of surrogate mothers on the MMPI-2. The findings revealed that the psychological suitability of surrogate mother candidates appear to be a composite of being both tough-minded and sensitive, sufficiently resilient to manage the role of surrogacy, and aware of the importance of emotional boundary-setting related to pre-natal attachment. Copyright © 2012 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  9. Argentina-LLNL-LANL Comparative Sample Analysis on UO2 fuel pellet CRM-125A for Nuclear Forensics

    Energy Technology Data Exchange (ETDEWEB)

    Kips, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-12-01

    The recent workshop on analytical plan development provided context and background for the next step in this engagement, i.e. a comparative sample analysis on CRM 125-A. This is a commercially available certified low-enriched uranium oxide fuel pellet material from New Brunswick National Laboratory (NBL) (see certificate in Annex 1).

  10. Comparative Study of 11 Honey Samples Sold in Riyadh Saudi Arabia

    OpenAIRE

    Al Tufail, M. A. [محمد عبد الله الطفيل; Al Araidh, I. A. [ابراهيم عبد الله العريض

    2006-01-01

    11 honey various samples commercially available in Saudi Arabia, were subjected to chemical, toxicological and bacteriological tests. The samples were checked for As and CN, presence of pollens, and for bacteria contamination. The carbohydrate profile was analyzed with HPLC. Fe, P, Ca, K, and Mg were measured with colorimetry. Toxic metals, As, Pb, Sb, Tl, and Hg were determined with ICP-MS. The samples were investigated by GC-MS. The investigation revealed the presence of syringaldehyde, men...

  11. A comparative examination of several techniques for the routine determination of mercury in biological samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Faanhof, A.; Das, H.A.

    1978-01-01

    A comparative examination of the most important techniques for the separation of mercury from irradiated biological material was made. Procedures for routine analysis and results for standard materials are given. Activation was performed at a thermal neutron flux of approximately 5x10 12 nxcm -2 xs -1 during ( 3 ) 2 offers a convenient solution to this problem. The variation of the neutron flux with the irradiation position can be measured by the application of thin iron rings as flux monitors. Losses of mercury due to uptake in the wall of the irradiation containers are negligible. The most powerful destruction technique for large samples is that based on a stainless-steel bomb. (T. I.)

  12. 40 CFR 761.298 - Decisions based on PCB concentration measurements resulting from sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Decisions based on PCB concentration... Cleanup and On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6) § 761.298 Decisions based on PCB concentration measurements resulting from sampling. (a) For...

  13. An unsupervised MVA method to compare specific regions in human breast tumor tissue samples using ToF-SIMS.

    Science.gov (United States)

    Bluestein, Blake M; Morrish, Fionnuala; Graham, Daniel J; Guenthoer, Jamie; Hockenbery, David; Porter, Peggy L; Gamble, Lara J

    2016-03-21

    Imaging time-of-flight secondary ion mass spectrometry (ToF-SIMS) and principal component analysis (PCA) were used to investigate two sets of pre- and post-chemotherapy human breast tumor tissue sections to characterize lipids associated with tumor metabolic flexibility and response to treatment. The micron spatial resolution imaging capability of ToF-SIMS provides a powerful approach to attain spatially-resolved molecular and cellular data from cancerous tissues not available with conventional imaging techniques. Three ca. 1 mm(2) areas per tissue section were analyzed by stitching together 200 μm × 200 μm raster area scans. A method to isolate and analyze specific tissue regions of interest by utilizing PCA of ToF-SIMS images is presented, which allowed separation of cellularized areas from stromal areas. These PCA-generated regions of interest were then used as masks to reconstruct representative spectra from specifically stromal or cellular regions. The advantage of this unsupervised selection method is a reduction in scatter in the spectral PCA results when compared to analyzing all tissue areas or analyzing areas highlighted by a pathologist. Utilizing this method, stromal and cellular regions of breast tissue biopsies taken pre- versus post-chemotherapy demonstrate chemical separation using negatively-charged ion species. In this sample set, the cellular regions were predominantly all cancer cells. Fatty acids (i.e. palmitic, oleic, and stearic), monoacylglycerols, diacylglycerols and vitamin E profiles were distinctively different between the pre- and post-therapy tissues. These results validate a new unsupervised method to isolate and interpret biochemically distinct regions in cancer tissues using imaging ToF-SIMS data. In addition, the method developed here can provide a framework to compare a variety of tissue samples using imaging ToF-SIMS, especially where there is section-to-section variability that makes it difficult to use a serial hematoxylin

  14. New sample carrier systems for thermogravimetric analysis under forced flow conditions and their influence on microkinetic results.

    Science.gov (United States)

    Seibel, C; Fieback, T M

    2015-09-01

    For thermogravimetric analysis, it has been shown that, depending on the type of sample container, different kinetic results could be obtained despite regarding the same reaction under constant conditions. This is due to limiting macrokinetic effects which are strongly dependant on the type of sample carrying system. This prompted the need for sample containers which deliver results minimally limited by diffusive mass transport. In this way, two container systems were developed, both characterized by a forced flow stream through a solid, porous bed: one from bottom to top (counter-current flow) and one from top to bottom (co-current flow). Optical test measurements were performed, the results indicating that reaction proceedings are almost fully independent of the geometrical shape of the sample containers. The Boudouard reaction was investigated with a standard crucible and the new developed systems; the reaction rates determined differed significantly, up to a factor of 6.2 at 1373 K.

  15. A comparative examination of sample treatment procedures for ICAP-AES analysis of biological tissue

    Science.gov (United States)

    De Boer, J. L. M.; Maessen, F. J. M. J.

    The objective of this study was to contribute to the evaluation of existing sample preparation procedures for ICAP-AES analysis of biological material. Performance characteristics were established of current digestion procedures comprising extraction, solubilization, pressure digestion, and wet and dry ashing methods. Apart from accuracy and precision, a number of criteria of special interest for the analytical practice was applied. As a test sample served SRM bovine liver. In this material six elements were simultaneously determined. Results showed that every procedure has its defects and advantages. Hence, unambiguous recommendation of standard digestion procedures can be made only when taking into account the specific analytical problem.

  16. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Interpreting PCB concentration... § 761.79(b)(3) § 761.316 Interpreting PCB concentration measurements resulting from this sampling... composite is 20 µg/100 cm2, then the entire 9.5 square meters has a PCB surface concentration of 20 µg/100...

  17. Headspace vapor characterization of Hanford waste Tank 241-BX-110: Results from samples collected on 04/30/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-BX-110 (Tank BX-110) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in a table. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples are also listed in the table. Detailed descriptions of the analytical results appear in the appendices

  18. Failure Probability Estimation Using Asymptotic Sampling and Its Dependence upon the Selected Sampling Scheme

    Directory of Open Access Journals (Sweden)

    Martinásková Magdalena

    2017-12-01

    Full Text Available The article examines the use of Asymptotic Sampling (AS for the estimation of failure probability. The AS algorithm requires samples of multidimensional Gaussian random vectors, which may be obtained by many alternative means that influence the performance of the AS method. Several reliability problems (test functions have been selected in order to test AS with various sampling schemes: (i Monte Carlo designs; (ii LHS designs optimized using the Periodic Audze-Eglājs (PAE criterion; (iii designs prepared using Sobol’ sequences. All results are compared with the exact failure probability value.

  19. Tank 241-U-104 headspace gas and vapor characterization results from samples collected on July 16, 1996

    International Nuclear Information System (INIS)

    Pool, K.H.; Evans, J.C.; Hayes, J.C.; Mitroshkov, A.V.; Edwards, J.A.; Julya, J.L.; Thornton, B.M.; Fruchter, J.S.; Silvers, K.L.

    1997-08-01

    This report presents the results from analyses of samples taken from the headspace of waste storage tank 241-U-104 (Tank U-104) at the Hanford Site in Washington State. Tank headspace samples collected by Westinghouse Hanford Company (WHC) were analyzed by Pacific Northwest National Laboratory (PNNL) to determine headspace concentrations of selected non-radioactive analytes. Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Vapor concentrations from sorbent trap samples are based on measured sample volumes provided by WHC. No analytes were determined to be above the immediate notification limits specified by the sampling and analysis plan. None of the flammable constituents were present at concentrations above the analytical instrument detection limits. Total headspace flammability was estimated to be <0.108% of the lower flammability limit. Average measured concentrations of targeted gases, inorganic vapors, and selected organic vapors are provided in a table. A summary of experimental methods, including sampling methodology, analytical procedures, and quality assurance and control methods are presented in Section 2.0. Detailed descriptions of the analytical results are provided in Section 3.0

  20. Comparative research of effectiveness of cellulose and fiberglass porous membrane carriers for bio sampling in veterinary and food industry monitoring

    Science.gov (United States)

    Gusev, Alexander; Vasyukova, Inna; Zakharova, Olga; Altabaeva, Yuliya; Saushkin, Nikolai; Samsonova, Jeanne; Kondakov, Sergey; Osipov, Alexander; Snegin, Eduard

    2017-11-01

    The aim of proposed research is to study the applicability of fiberglass porous membrane materials in a new strip format for dried blood storage in food industry monitoring. A comparative analysis of cellulosic and fiberglass porous membrane materials was carried out to obtain dried samples of serum or blood and the possibility of further species-specific analysis. Blood samples of Sus scrofa were used to study the comparative effectiveness of cellulose and fiberglass porous membrane carriers for long-term biomaterial storage allowing for further DNA detection by real-time polymerase chain reaction (PCR) method. Scanning electron microscopy of various membranes - native and with blood samples - indicate a fundamental difference in the form of dried samples. Membranes based on cellulosic materials sorb the components of the biological fluid on the surface of the fibers of their structure, partially penetrating the cellulose fibers, while in the case of glass fiber membranes the components of the biological fluid dry out as films in the pores of the membrane between the structural filaments. This fundamental difference in the retention mechanisms affects the rate of dissolution of the components of dry samples and contributes to an increase in the efficiency of the desorption process of the sample before subsequent analysis. Detecting of pig DNA in every analyzed sample under the performed Real-time PCR as well as good state of the biomaterial preservation on the glass fiber membranes was clearly demonstrated. Good biomaterials preservation has been revealed on the test cards for 4 days as well as for 1 hour.

  1. DNA barcoding of selected UAE medicinal plant species: a comparative assessment of herbarium and fresh samples.

    Science.gov (United States)

    Enan, Mohamed Rizk; Palakkott, Abdul Rasheed; Ksiksi, Taoufik Saleh

    2017-01-01

    It is commonly difficult to extract and amplify DNA from herbarium samples as they are old and preserved using different compounds. In addition, such samples are subjected to the accumulation of intrinsically produced plant substances over long periods (up to hundreds of years). DNA extraction from desert flora may pause added difficulties as many contain high levels of secondary metabolites. Herbarium samples from the Biology Department (UAE University) plant collection and fresh plant samples, collected from around Al-Ain (UAE), were used in this study. The three barcode loci for the coding genes matK, rbcL and rpoC1-were amplified. Our results showed that T. terresteris , H. robustum , T. pentandrus and Z. qatarense were amplified using all three primers for both fresh and herbaium samples. Both fresh and herbarium samples of C. comosum , however, were not amplified at all, using the three primers. Herbarium samples from A. javanica , C. imbricatum , T. aucherana and Z. simplex were not amplified with any of the three primers. For fresh samples 90, 90 and 80% of the samples were amplified using matK, rbcL and rpoC1, respectively. In short, fresh samples were significantly better amplified than those from herbarium sources, using the three primers. Both fresh and herbarium samples from one species ( C. comosum ), however, were not successfully amplified. It is also concluded that the rbcL regions showed real potentials to distinguish the UAE species under investigation into the appropriate family and genus.

  2. Headspace vapor characterization of Hanford waste tank 241-U-108: Results from samples collected on 8/29/95

    International Nuclear Information System (INIS)

    Thomas, B.L.; Clauss, T.W.; Evans, J.C.; McVeety, B.D.; Pool, K.H.; Olsten, K.B.; Fruchter, J.S.; Ligotke, M.W.

    1996-05-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-U-108 (Tank U-108) at the Hanford Site in Washington State. The results described in the report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC

  3. Problematic Social Media Use: Results from a Large-Scale Nationally Representative Adolescent Sample.

    Science.gov (United States)

    Bányai, Fanni; Zsila, Ágnes; Király, Orsolya; Maraz, Aniko; Elekes, Zsuzsanna; Griffiths, Mark D; Andreassen, Cecilie Schou; Demetrovics, Zsolt

    2017-01-01

    Despite social media use being one of the most popular activities among adolescents, prevalence estimates among teenage samples of social media (problematic) use are lacking in the field. The present study surveyed a nationally representative Hungarian sample comprising 5,961 adolescents as part of the European School Survey Project on Alcohol and Other Drugs (ESPAD). Using the Bergen Social Media Addiction Scale (BSMAS) and based on latent profile analysis, 4.5% of the adolescents belonged to the at-risk group, and reported low self-esteem, high level of depression symptoms, and elevated social media use. Results also demonstrated that BSMAS has appropriate psychometric properties. It is concluded that adolescents at-risk of problematic social media use should be targeted by school-based prevention and intervention programs.

  4. Sampling pig farms at the abattoir in a cross-sectional study - Evaluation of a sampling method.

    Science.gov (United States)

    Birkegård, Anna Camilla; Halasa, Tariq; Toft, Nils

    2017-09-15

    procedure was reproducible with results comparable to the collected sample. However, the sampling procedure favoured sampling of large farms. Furthermore, both under-sampled and over-sampled areas were found using scan statistics. In conclusion, sampling conducted at abattoirs can provide a spatially representative sample. Hence it is a possible cost-effective alternative to simple random sampling. However, it is important to assess the properties of the resulting sample so that any potential selection bias can be addressed when reporting the findings. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. 2015 Long-Term Hydrologic Monitoring Program Sampling and Analysis Results at Rio Blanco, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Findlay, Rick [Nararro Research and Engineering, Oak Ridge, TN (United States); Kautsky, Mark [US Department of Energy, Washington, DC (United States). Office of Legacy Management

    2015-12-01

    The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rio Blanco, Colorado, Site for the Long-Term Hydrologic Monitoring Program (LTHMP) on May 20–21, 2015. This report documents the analytical results of the Rio Blanco annual monitoring event, the trip report, and the data validation package. The groundwater and surface water monitoring samples were shipped to the GEL Group Inc. laboratories for conventional analysis of tritium and analysis of gamma-emitting radionuclides by high-resolution gamma spectrometry. A subset of water samples collected from wells near the Rio Blanco site was also sent to GEL Group Inc. for enriched tritium analysis. All requested analyses were successfully completed. Samples were collected from a total of four onsite wells, including two that are privately owned. Samples were also collected from two additional private wells at nearby locations and from nine surface water locations. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry, and they were analyzed for tritium using the conventional method with a detection limit on the order of 400 picocuries per liter (pCi/L). Four locations (one well and three surface locations) were analyzed using the enriched tritium method, which has a detection limit on the order of 3 pCi/L. The enriched locations included the well at the Brennan Windmill and surface locations at CER-1, CER-4, and Fawn Creek 500 feet upstream.

  6. A comparison of fitness-case sampling methods for genetic programming

    Science.gov (United States)

    Martínez, Yuliana; Naredo, Enrique; Trujillo, Leonardo; Legrand, Pierrick; López, Uriel

    2017-11-01

    Genetic programming (GP) is an evolutionary computation paradigm for automatic program induction. GP has produced impressive results but it still needs to overcome some practical limitations, particularly its high computational cost, overfitting and excessive code growth. Recently, many researchers have proposed fitness-case sampling methods to overcome some of these problems, with mixed results in several limited tests. This paper presents an extensive comparative study of four fitness-case sampling methods, namely: Interleaved Sampling, Random Interleaved Sampling, Lexicase Selection and Keep-Worst Interleaved Sampling. The algorithms are compared on 11 symbolic regression problems and 11 supervised classification problems, using 10 synthetic benchmarks and 12 real-world data-sets. They are evaluated based on test performance, overfitting and average program size, comparing them with a standard GP search. Comparisons are carried out using non-parametric multigroup tests and post hoc pairwise statistical tests. The experimental results suggest that fitness-case sampling methods are particularly useful for difficult real-world symbolic regression problems, improving performance, reducing overfitting and limiting code growth. On the other hand, it seems that fitness-case sampling cannot improve upon GP performance when considering supervised binary classification.

  7. Sample Exchange Evaluation (SEE) Report - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Winters, W.I.

    1994-09-28

    This report describes the results from Phase II of the Sample Exchange Evaluation (SEE) Program, a joint effort to compare analytical laboratory performance on samples from the Hanford Site`s high-level waste tanks. In Phase II, the program has been expanded to include inorganic constituents in addition to radionuclides. Results from Phase II that exceeded 20% relative percent difference criteria are identified.

  8. Sample Exchange Evaluation (SEE) Report - Phase II

    International Nuclear Information System (INIS)

    Winters, W.I.

    1994-01-01

    This report describes the results from Phase II of the Sample Exchange Evaluation (SEE) Program, a joint effort to compare analytical laboratory performance on samples from the Hanford Site's high-level waste tanks. In Phase II, the program has been expanded to include inorganic constituents in addition to radionuclides. Results from Phase II that exceeded 20% relative percent difference criteria are identified

  9. Swab2know: An HIV-Testing Strategy Using Oral Fluid Samples and Online Communication of Test Results for Men Who Have Sex With Men in Belgium.

    Science.gov (United States)

    Platteau, Tom; Fransen, Katrien; Apers, Ludwig; Kenyon, Chris; Albers, Laura; Vermoesen, Tine; Loos, Jasna; Florence, Eric

    2015-09-01

    As HIV remains a public health concern, increased testing among those at risk for HIV acquisition is important. Men who have sex with men (MSM) are the most important group for targeted HIV testing in Europe. Several new strategies have been developed and implemented to increase HIV-testing uptake in this group, among them the Swab2know project. In this project, we aim to assess the acceptability and feasibility of outreach and online HIV testing using oral fluid samples as well as Web-based delivery of test results. Sample collection happened between December 2012 and April 2014 via outreach and online sampling among MSM. Test results were communicated through a secured website. HIV tests were executed in the laboratory. Each reactive sample needed to be confirmed using state-of-the-art confirmation procedures on a blood sample. Close follow-up of participants who did not pick up their results, and those with reactive results, was included in the protocol. Participants were asked to provide feedback on the methodology using a short survey. During 17 months, 1071 tests were conducted on samples collected from 898 men. Over half of the samples (553/1071, 51.63%) were collected during 23 outreach sessions. During an 8-month period, 430 samples out of 1071 (40.15%) were collected from online sampling. Additionally, 88 samples out of 1071 (8.22%) were collected by two partner organizations during face-to-face consultations with MSM and male sex workers. Results of 983 out of 1071 tests (91.78%) had been collected from the website. The pickup rate was higher among participants who ordered their kit online (421/430, 97.9%) compared to those participating during outreach activities (559/641, 87.2%; Ponline participants were more likely to have never been tested before (17.3% vs 10.0%; P=.001) and reported more sexual partners in the 6 months prior to participation in the project (mean 7.18 vs 3.23; Ponline counseling tool), and in studying the cost effectiveness of the

  10. Recent results of the investigation of a micro-fluidic sampling chip and sampling system for hot cell aqueous processing streams

    International Nuclear Information System (INIS)

    Tripp, J.; Smith, T.; Law, J.

    2013-01-01

    A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and micro-fluidic sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. Different sampling volumes have been tested. It appears that the 10 μl volume has produced data that had much smaller relative standard deviations than the 2 μl volume. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The micro-fluidic-based robotic sampling system's mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of micro-fluidic sampling chips. (authors)

  11. Protocol for Cohesionless Sample Preparation for Physical Experimentation

    Science.gov (United States)

    2016-05-01

    Standard test method for consolidated drained triaxial compression test for soils . In Annual book of ASTM standards. West Conshohocken, PA: ASTM...derived wherein uncertainties and laboratory scatter associated with soil fabric-behavior variance during sample preparation are mitigated. Samples of...wherein comparable analysis between different laboratory tests’ results can be made by ensuring a comparable soil fabric prior to laboratory testing

  12. Tank Farm WM-182 and WM-183 Heel Slurry Samples PSD Results

    International Nuclear Information System (INIS)

    Batcheller, T.A.; Huestis, G.M.

    2000-01-01

    Particle size distribution (PSD) analysis of INTEC Tank Farm WM-182 and WM-183 heel slurry samples were performed using a modified Horiba LA-300 PSD analyzer at the RAL facility. There were two types of testing performed: typical PSD analysis, and setting rate testing. Although the heel slurry samples were obtained from two separate vessels, the particle size distribution results were quite similar. The slurry solids were from approximately a minimum particle size of 0.5 mm to a maximum of 230 mm with about 90% of the material between 2-to-133 mm, and the cumulative 50% value at approximately 20 mm. This testing also revealed that high frequency sonication with an ultrasonic element may break-up larger particles in the WM-182 and WM-183 tank from heel slurries. This finding represents useful information regarding ultimate tank heel waste processing. Settling rate testing results were also fairly consistent with material from both vessels in that it appears that most of the mass of solids settle to an agglomerated, yet easily redispersed layer at the bottom. A dispersed and suspended material remained in the ''clear'' layer above the settled layer after about one-half an hour of settling time. This material had a statistical mode of approximately 5 mm and a maximum particle size of 30 mm

  13. Urine sampling techniques in symptomatic primary-care patients

    DEFF Research Database (Denmark)

    Holm, Anne; Aabenhus, Rune

    2016-01-01

    in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. Conclusions: At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However......Background: Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection...... a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. Results: We included...

  14. A comprehensive analyzing and evaluating of the results of a wide scope comparison on the environmental level radioactive samples with γ spectrometer

    International Nuclear Information System (INIS)

    Su Qiong; Cheng Jianping; Wang Xuewu; Fan Jiajin; Chen Boxian

    2001-01-01

    A wide scope comparison on the environmental level radioactive samples by γ spectrometers, that has been done in 1998 - 1999, was introduced. Some original data about the comparison are presented. Comprehensive analyzing and evaluating on the comparison results have been done. A new method used for determining comparison reference values, the Model Real Time Weight Average, is adopted. The method is detailed and compared with other models. The practice shows that the Model Real Time Weight Average adopted is feasible and successful

  15. Compressive sampling of polynomial chaos expansions: Convergence analysis and sampling strategies

    International Nuclear Information System (INIS)

    Hampton, Jerrad; Doostan, Alireza

    2015-01-01

    Sampling orthogonal polynomial bases via Monte Carlo is of interest for uncertainty quantification of models with random inputs, using Polynomial Chaos (PC) expansions. It is known that bounding a probabilistic parameter, referred to as coherence, yields a bound on the number of samples necessary to identify coefficients in a sparse PC expansion via solution to an ℓ 1 -minimization problem. Utilizing results for orthogonal polynomials, we bound the coherence parameter for polynomials of Hermite and Legendre type under their respective natural sampling distribution. In both polynomial bases we identify an importance sampling distribution which yields a bound with weaker dependence on the order of the approximation. For more general orthonormal bases, we propose the coherence-optimal sampling: a Markov Chain Monte Carlo sampling, which directly uses the basis functions under consideration to achieve a statistical optimality among all sampling schemes with identical support. We demonstrate these different sampling strategies numerically in both high-order and high-dimensional, manufactured PC expansions. In addition, the quality of each sampling method is compared in the identification of solutions to two differential equations, one with a high-dimensional random input and the other with a high-order PC expansion. In both cases, the coherence-optimal sampling scheme leads to similar or considerably improved accuracy

  16. Compressive sampling of polynomial chaos expansions: Convergence analysis and sampling strategies

    Science.gov (United States)

    Hampton, Jerrad; Doostan, Alireza

    2015-01-01

    Sampling orthogonal polynomial bases via Monte Carlo is of interest for uncertainty quantification of models with random inputs, using Polynomial Chaos (PC) expansions. It is known that bounding a probabilistic parameter, referred to as coherence, yields a bound on the number of samples necessary to identify coefficients in a sparse PC expansion via solution to an ℓ1-minimization problem. Utilizing results for orthogonal polynomials, we bound the coherence parameter for polynomials of Hermite and Legendre type under their respective natural sampling distribution. In both polynomial bases we identify an importance sampling distribution which yields a bound with weaker dependence on the order of the approximation. For more general orthonormal bases, we propose the coherence-optimal sampling: a Markov Chain Monte Carlo sampling, which directly uses the basis functions under consideration to achieve a statistical optimality among all sampling schemes with identical support. We demonstrate these different sampling strategies numerically in both high-order and high-dimensional, manufactured PC expansions. In addition, the quality of each sampling method is compared in the identification of solutions to two differential equations, one with a high-dimensional random input and the other with a high-order PC expansion. In both cases, the coherence-optimal sampling scheme leads to similar or considerably improved accuracy.

  17. Headspace vapor characterization of Hanford waste tank 241-U-109: Results from samples collected on 8/10/95

    International Nuclear Information System (INIS)

    Evans, J.C.; Thomas, B.L.; Pool, K.H.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1996-05-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-U-109 (Tank U-109) At the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. This tank is on the Hydrogen Waste List. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the inorganic analytes, permanent gases and total non-methane hydrocarbons is listed in a table. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples is also listed in the table. Detailed descriptions of the analytical results appear in the text

  18. Problematic Social Media Use: Results from a Large-Scale Nationally Representative Adolescent Sample.

    Directory of Open Access Journals (Sweden)

    Fanni Bányai

    Full Text Available Despite social media use being one of the most popular activities among adolescents, prevalence estimates among teenage samples of social media (problematic use are lacking in the field. The present study surveyed a nationally representative Hungarian sample comprising 5,961 adolescents as part of the European School Survey Project on Alcohol and Other Drugs (ESPAD. Using the Bergen Social Media Addiction Scale (BSMAS and based on latent profile analysis, 4.5% of the adolescents belonged to the at-risk group, and reported low self-esteem, high level of depression symptoms, and elevated social media use. Results also demonstrated that BSMAS has appropriate psychometric properties. It is concluded that adolescents at-risk of problematic social media use should be targeted by school-based prevention and intervention programs.

  19. Sampling low-density gypsy moth populations

    Science.gov (United States)

    William E. Wallner; Clive G. Jones; Joseph S. Elkinton; Bruce L. Parker

    1991-01-01

    The techniques and methodology for sampling gypsy moth, Lymantria dispar L., at low densities, less than 100 egg masses/ha (EM/ha), are compared. Forest managers have constraints of time and cost, and need a useful, simple predictable means to assist them in sampling gypsy moth populations. A comparison of various techniques coupled with results of...

  20. The results of experimental studies of VLF–ULF electromagnetic emission by rock samples due to mechanical action

    OpenAIRE

    A. A. Panfilov

    2013-01-01

    The paper presents the results of laboratory experiments on electromagnetic emission excitation (electric component of electromagnetic field) by rock samples due to different forms of mechanical stress applications. It was shown that samples generate electric impulses with different spectra when the impact action, gradual loading or dynamic friction is applied. It was ascertained that level and spectral compositions of signals, generated by rock samples, cha...

  1. Comparative study of the hydrodynamic drag reducer efficiency in petroleum samples; Estudo comparativo da eficiencia de redutores de atrito hidrodinamico comerciais em amostras de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Sabadini, Edvaldo; Silva, Marcelo Alves da [Universidade Estadual de Campinas (UNICAMP), SP (Brazil); Ziglio, Claudio Marcos; Carvalho, Carlos Henrique Monteiro de; Rocha, Nelson de Oliveira [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2008-07-01

    In this work the efficiency of five commercial additives which produce drag reduction in petroleum was determined and compared. The studies were carried out in a rheometer using samples of petroleum from Bacia de Campos diluted in 50% of toluene. For such purpose the rheometer acts as a 'torquemeter', in which the magnitude of the drag reduction promoted by the additive is directly proportional to the difference in torque applied to maintain the sample in a specific flow rate. The obtained results have shown excellent capability of the additives to promote drag reduction (up to 20%) and small difference of efficiency among the additives was detectable. (author)

  2. Results of stainless steel canister corrosion studies and environmental sample investigations

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Laboratories, Albuquerque, NM (United States); Enos, David [Sandia National Laboratories, Albuquerque, NM (United States)

    2014-12-01

    This progress report describes work being done at Sandia National Laboratories (SNL) to assess the localized corrosion performance of container/cask materials used in the interim storage of used nuclear fuel. The work involves both characterization of the potential physical and chemical environment on the surface of the storage canisters and how it might evolve through time, and testing to evaluate performance of the canister materials under anticipated storage conditions. To evaluate the potential environment on the surface of the canisters, SNL is working with the Electric Power Research Institute (EPRI) to collect and analyze dust samples from the surface of in-service SNF storage canisters. In FY 13, SNL analyzed samples from the Calvert Cliffs Independent Spent Fuel Storage Installation (ISFSI); here, results are presented for samples collected from two additional near-marine ISFSI sites, Hope Creek NJ, and Diablo Canyon CA. The Hope Creek site is located on the shores of the Delaware River within the tidal zone; the water is brackish and wave action is normally minor. The Diablo Canyon site is located on a rocky Pacific Ocean shoreline with breaking waves. Two types of samples were collected: SaltSmart™ samples, which leach the soluble salts from a known surface area of the canister, and dry pad samples, which collected a surface salt and dust using a swipe method with a mildly abrasive ScotchBrite™ pad. The dry samples were used to characterize the mineralogy and texture of the soluble and insoluble components in the dust via microanalytical techniques, including mapping X-ray Fluorescence spectroscopy and Scanning Electron Microscopy. For both Hope Creek and Diablo Canyon canisters, dust loadings were much higher on the flat upper surfaces of the canisters than on the vertical sides. Maximum dust sizes collected at both sites were slightly larger than 20 μm, but Phragmites grass seeds ~1 mm in size, were observed on the tops of the Hope Creek canisters

  3. CIEMAT results in IAEA proficiency tests in the context of emergency situations (210Po, 239,240Pu, 210Pb, gamma-emitters and 241Am) in environmental samples

    International Nuclear Information System (INIS)

    Gasco, Catalina; Suanez, Ana; Fernandez, Eva; Meral, Jose; Trinidad, Jose A.; Navarro, Nuria; Alvarez, Alicia; Higueras, Ernesto

    2008-01-01

    Three laboratories of CIEMAT with different: radiochemical procedures, detection capacity levels and counting equipment took part in the IAEA proficiency tests IAEA-CU-2007-09 and IAEA-CU-2007-04 (2007- 2008). This participation has allowed to compare and optimize some techniques in the case of emergency situations. The diverse methods used for the radionuclides determination, the capacity of each method for separating appropriately the radionuclides and their precision and trueness have been studied comparatively. The results of these exercises showed that the natural occurring radionuclides existing in the environmental samples are best isolated by time consuming analytical methods. Nevertheless, emergency methods require less manipulation, lower aliquot of sample and permit an acceptable detection limit for the radionuclides quantification. The selection of a radiochemical method for a specific purpose depends mainly on the sensibility required by the labs. The IAEA evaluation of the results as well as, our evaluation taking into account our capacities and objectives, are presented in this work. (author)

  4. Special nuclear material inventory sampling plans

    International Nuclear Information System (INIS)

    Vaccaro, H.; Goldman, A.

    1987-01-01

    Since their introduction in 1942, sampling inspection procedures have been common quality assurance practice. The U.S. Department of Energy (DOE) supports such sampling of special nuclear materials inventories. The DOE Order 5630.7 states, Operations Offices may develop and use statistically valid sampling plans appropriate for their site-specific needs. The benefits for nuclear facilities operations include reduced worker exposure and reduced work load. Improved procedures have been developed for obtaining statistically valid sampling plans that maximize these benefits. The double sampling concept is described and the resulting sample sizes for double sample plans are compared with other plans. An algorithm is given for finding optimal double sampling plans that assist in choosing the appropriate detection and false alarm probabilities for various sampling plans

  5. Solvent Hold Tank Sample Results for MCU-16-991-992-993: July 2016 Monthly sample and MCU-16-1033-1034-1035: July 2016 Superwashed Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-11-25

    SRNL received one set of SHT samples (MCU-16-991, MCU-16-992 and MCU-16-993), pulled on 07/13/2016 and another set of SHT samples (MCU-16-1033, MCU-16-1034, and MCU-16-1035) that were pulled on 07/24/2016 after the solvent was superwashed with 300 mM sodium hydroxide for analysis. Samples MCU-16-991, MCU-16-992, and MCU-16-993 were combined into one sample (MCU-16-991-992-993) and samples MCU-16-1033, MCU-16-1034, and MCU-16-1035 were combined into one sample (MCU-16-1033-1034-1035). Of the two composite samples MCU-16-1033-1034-1035 represents the current chemical state of the solvent at MCU. All analytical conclusions are based on the chemical analysis of MCU-16-1033-1034-1035. There were no chemical differences between MCU-16- 991-992-993 and superwashed MCU-16-1033-1034-1035.

  6. Comparative Evaluation of Cheese samples treated with Honey and ...

    African Journals Online (AJOL)

    The control treatment (A) was cheese kept in the whey, while Treatments B and C were cheese samples kept in Thyme and Honey solutions respectively. ... The crude protein was significantly higher (p<0.05) for Treatment B, then treatment A and least for treatment C. The ether extract followed the same trend as crude ...

  7. Vapor space characterization of Waste Tank 241-C-103: Inorganic results from sample Job 7B (May 12-25, 1994)

    International Nuclear Information System (INIS)

    Ligotke, M.W.; Pool, K.H.; Lerner, B.D.

    1994-10-01

    This report is to provide analytical results for use in safety and toxicological evaluations of the vapor space of Hanford single-shell waste storage tanks C-103. Samples were analysed to determine concentrations of ammonia, nitric oxide, nitrogen dioxide, sulfur oxides, and hydrogen cyanide. In addition to the samples, controls were analyzed that included blanks, spiked blanks, and spiked samples. These controls provided information about the suitability of sampling and analytical methods. Also included are the following: information describing the methods and sampling procedures used; results of sample analyses; and Conclusions and recommendations

  8. 2015 Long-Term Hydrologic Monitoring Program Sampling and Analysis Results Report for Project Rulison, Co

    Energy Technology Data Exchange (ETDEWEB)

    Findlay, Rick [Navarro Research and Engineering, Oak Ridge, TN (United States); Kautsky, Mark [US Department of Energy, Washington, DC (United States). Office of Legacy Management

    2015-12-01

    The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rulison, Colorado, Site for the Long-Term Hydrologic Monitoring Program (LTHMP) on May 20–22 and 27, 2015. Several of the land owners were not available to allow access to their respective properties, which created the need for several sample collection trips. This report documents the analytical results of the Rulison monitoring event and includes the trip report and the data validation package (Appendix A). The groundwater and surface water monitoring were shipped to the GEL Group Inc. laboratories for analysis. All requested analyses were successfully completed. Samples were analyzed for gamma-emitting radionuclides by high- resolution gamma spectrometry. Tritium was analyzed using two methods, the conventional tritium method, which has a detection limit on the order of 400 picocuries per liter (pCi/L), and the enriched method (for selected samples), which has a detection limit on the order of 3 pCi/L.

  9. Estimating cyclopoid copepod species richness and geographical distribution (Crustacea across a large hydrographical basin: comparing between samples from water column (plankton and macrophyte stands

    Directory of Open Access Journals (Sweden)

    Gilmar Perbiche-Neves

    2014-06-01

    Full Text Available Species richness and geographical distribution of Cyclopoida freshwater copepods were analyzed along the "La Plata" River basin. Ninety-six samples were taken from 24 sampling sites, twelve sites for zooplankton in open waters and twelve sites for zooplankton within macrophyte stands, including reservoirs and lotic stretches. There were, on average, three species per sample in the plankton compared to five per sample in macrophytes. Six species were exclusive to the plankton, 10 to macrophyte stands, and 17 were common to both. Only one species was found in similar proportions in plankton and macrophytes, while five species were widely found in plankton, and thirteen in macrophytes. The distinction between species from open water zooplankton and macrophytes was supported by nonmetric multidimensional analysis. There was no distinct pattern of endemicity within the basin, and double sampling contributes to this result. This lack of sub-regional faunal differentiation is in accordance with other studies that have shown that cyclopoids generally have wide geographical distribution in the Neotropics and that some species there are cosmopolitan. This contrasts with other freshwater copepods such as Calanoida and some Harpacticoida. We conclude that sampling plankton and macrophytes together provided a more accurate estimate of the richness and geographical distribution of these organisms than sampling in either one of those zones alone.

  10. BRDF of Salt Pan Regolith Samples

    Science.gov (United States)

    Georgiev, Georgi T.; Gatebe, Charles K.; Butler, James J.; King, Michael D.

    2008-01-01

    Laboratory Bi-directional Reflectance Distribution Function (BRDF) measurements of salt pan regolith samples are presented in this study in an effort to understand the role of spatial and spectral variability of the natural biome. The samples were obtained from Etosha Pan, Namibia (19.20 deg S, 15.93 deg E, alt. 1100 m). It is shown how the BRDF depends on the measurement geometry - incident and scatter angles and on the sample particle sizes. As a demonstration of the application of the results, airborne BRDF measurements acquires with NASA's Cloud Absorption Radiometer (CAR) over the same general site where the regolith samples were collected are compared with the laboratory results. Good agreement between laboratory measured and field measured BRDF is reported.

  11. Two sampling techniques for game meat

    Directory of Open Access Journals (Sweden)

    Maretha van der Merwe

    2013-03-01

    Full Text Available A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g and square centimetres (cm2 for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12 that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13 and analyses performed for aerobic plate count (APC, Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  12. Two sampling techniques for game meat.

    Science.gov (United States)

    van der Merwe, Maretha; Jooste, Piet J; Hoffman, Louw C; Calitz, Frikkie J

    2013-03-20

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13) and analyses performed for aerobic plate count (APC), Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  13. Solvent Hold Tank Sample Results For MCU-11-1452, MCU-11-1453, MCU-11-1454, MCU-11-1455, MCU-11-1456 And MCU-11-1457

    International Nuclear Information System (INIS)

    Peters, T.; Fondeur, F.; Fink, S.

    2012-01-01

    Solvent Hold Tank (SHT) samples are sent to Savannah River National Laboratory (SRNL) to examine solvent composition changes over time. On December 5, 2011, Operations personnel delivered six samples from the SHT (MCU-11-1452 through -1457) for analysis. These samples are intended to verify that the solvent is within the specified composition range. The results from the analyses are presented in this document. Samples were received in p-nut vials containing ∼10 mL each. Once taken into the Shielded Cells, the samples were combined. Samples were removed for analysis by density, semi-volatile organic analysis (SVOA), high performance liquid chromatography (HPLC), and Fourier-Transform Infra-Red spectroscopy (FTIR). Details for the work are contained in a controlled laboratory notebook. Each of the six p-nut vials contained a single phase, with no apparent solids contamination or cloudiness. Table 1 contains the results of the analyses for the combined samples. A duplicate density measurement of the organic phase gave a result of 0.844 g/mL (1.2% residual standard deviation - RSD). Using the density as a starting point, we know that the Isopar(reg s ign) L should be slightly higher than nominal and the other components should be slightly lower than nominal. The results as a whole are internally consistent. All measurements indicate Isopar(reg s ign) L higher than nominal, and Modifier lower than nominal. The extractant result is higher than expected - given the other results, the extractant concentration should be under nominal values. Using the measured density as well as the Isopar(reg s ign) L and Modifier concentrations from the FTIR results, we calculate an extractant concentration of 6888 mg/L. This value is outside the analytical uncertainty of the reported HPLC value. Given the other results, this most likely indicates that the HPLC extractant result was biased high. When compared to the MCU density target of 0.845 g/mL, there is no need to add an Isopar

  14. Vapor space characterization of waste Tank 241-BY-108: Results from samples collected on 10/27/94

    International Nuclear Information System (INIS)

    McVeety, B.D.; Clauss, T.W.; Ligotke, M.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-BY-108 (referred to as Tank BY-108). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water vapor (H 2 O). Trends in NH 3 and H 2 O samples indicated a possible sampling problem. Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, the authors looked for the 40 TO-14 compounds plus an additional 15 analytes. Of these, 17 were observed above the 5-ppbv reporting cutoff. Also, eighty-one organic tentatively identified compounds (TICs) were observed above the reporting cutoff (ca.) 10 ppbv, and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. The nine organic analytes with the highest estimated concentrations are listed in Summary Table 1 and account for approximately 48% of the total organic components in the headspace of Tank BY-108. Three permanent gases, hydrogen (H 2 ), carbon dioxide (CO 2 ), and nitrous oxide (N 2 O) were also detected. Tank BY-108 is on the Ferrocyanide Watch List

  15. Vapor space characterization of waste tank 241-BY-105 (in situ): Results from samples collected on May 9, 1994

    International Nuclear Information System (INIS)

    McVeety, B.D.; Pool, K.H.; Ligotke, M.W.; Clauss, T.W.; Lucke, R.B.; Sharma, A.K.; McCulloch, M.; Fruchter, J.S.; Goheen, S.C.

    1995-05-01

    This report describes inorganic and organic analyses results from in situ samples obtained from the tank headspace of the Hanford waste storage Tank 241-BY-105 (referred to as Tank BY-105). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds NH 3 , NO 2 , NO, HCN, and H 2 O. Sampling for sulfur oxides was not requested. Results of the inorganic samples were affected by sampling errors that led to an undefined uncertainty in sample volume. Consequently, tank-headspace concentrations are estimated only. Thirty-nine tentatively identified organic analytes were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and their quantitation is beyond the scope of this study. In addition, we looked for the 41 standard TO-14 analytes. Of these, only a few were observed above the 2-ppbv detection limit. The 16 organic analytes with the highest estimated concentrations are listed. These 16 analytes account for approximately 68% of the total or organic components in Tank BY-105

  16. Headspace vapor characterization of Hanford Waste Tank 241-U-112: Results from samples collected on 7/09/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-U-112 at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company

  17. Effect of sample stratification on dairy GWAS results

    Directory of Open Access Journals (Sweden)

    Ma Li

    2012-10-01

    Full Text Available Abstract Background Artificial insemination and genetic selection are major factors contributing to population stratification in dairy cattle. In this study, we analyzed the effect of sample stratification and the effect of stratification correction on results of a dairy genome-wide association study (GWAS. Three methods for stratification correction were used: the efficient mixed-model association expedited (EMMAX method accounting for correlation among all individuals, a generalized least squares (GLS method based on half-sib intraclass correlation, and a principal component analysis (PCA approach. Results Historical pedigree data revealed that the 1,654 contemporary cows in the GWAS were all related when traced through approximately 10–15 generations of ancestors. Genome and phenotype stratifications had a striking overlap with the half-sib structure. A large elite half-sib family of cows contributed to the detection of favorable alleles that had low frequencies in the general population and high frequencies in the elite cows and contributed to the detection of X chromosome effects. All three methods for stratification correction reduced the number of significant effects. EMMAX method had the most severe reduction in the number of significant effects, and the PCA method using 20 principal components and GLS had similar significance levels. Removal of the elite cows from the analysis without using stratification correction removed many effects that were also removed by the three methods for stratification correction, indicating that stratification correction could have removed some true effects due to the elite cows. SNP effects with good consensus between different methods and effect size distributions from USDA’s Holstein genomic evaluation included the DGAT1-NIBP region of BTA14 for production traits, a SNP 45kb upstream from PIGY on BTA6 and two SNPs in NIBP on BTA14 for protein percentage. However, most of these consensus effects had

  18. Headspace vapor characterization of Hanford waste Tank 241-C-201: Results from samples collected on 06/19/96

    International Nuclear Information System (INIS)

    Thomas, B.L.; Evans, J.C.; Pool, K.H.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-C-201 (Tank C-201) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, on sample volumes provided by WHC. A summary, of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in a table. Detailed descriptions of the analytical results appear in the appendices

  19. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  20. Choosing a Cluster Sampling Design for Lot Quality Assurance Sampling Surveys.

    Directory of Open Access Journals (Sweden)

    Lauren Hund

    Full Text Available Lot quality assurance sampling (LQAS surveys are commonly used for monitoring and evaluation in resource-limited settings. Recently several methods have been proposed to combine LQAS with cluster sampling for more timely and cost-effective data collection. For some of these methods, the standard binomial model can be used for constructing decision rules as the clustering can be ignored. For other designs, considered here, clustering is accommodated in the design phase. In this paper, we compare these latter cluster LQAS methodologies and provide recommendations for choosing a cluster LQAS design. We compare technical differences in the three methods and determine situations in which the choice of method results in a substantively different design. We consider two different aspects of the methods: the distributional assumptions and the clustering parameterization. Further, we provide software tools for implementing each method and clarify misconceptions about these designs in the literature. We illustrate the differences in these methods using vaccination and nutrition cluster LQAS surveys as example designs. The cluster methods are not sensitive to the distributional assumptions but can result in substantially different designs (sample sizes depending on the clustering parameterization. However, none of the clustering parameterizations used in the existing methods appears to be consistent with the observed data, and, consequently, choice between the cluster LQAS methods is not straightforward. Further research should attempt to characterize clustering patterns in specific applications and provide suggestions for best-practice cluster LQAS designs on a setting-specific basis.

  1. Choosing a Cluster Sampling Design for Lot Quality Assurance Sampling Surveys.

    Science.gov (United States)

    Hund, Lauren; Bedrick, Edward J; Pagano, Marcello

    2015-01-01

    Lot quality assurance sampling (LQAS) surveys are commonly used for monitoring and evaluation in resource-limited settings. Recently several methods have been proposed to combine LQAS with cluster sampling for more timely and cost-effective data collection. For some of these methods, the standard binomial model can be used for constructing decision rules as the clustering can be ignored. For other designs, considered here, clustering is accommodated in the design phase. In this paper, we compare these latter cluster LQAS methodologies and provide recommendations for choosing a cluster LQAS design. We compare technical differences in the three methods and determine situations in which the choice of method results in a substantively different design. We consider two different aspects of the methods: the distributional assumptions and the clustering parameterization. Further, we provide software tools for implementing each method and clarify misconceptions about these designs in the literature. We illustrate the differences in these methods using vaccination and nutrition cluster LQAS surveys as example designs. The cluster methods are not sensitive to the distributional assumptions but can result in substantially different designs (sample sizes) depending on the clustering parameterization. However, none of the clustering parameterizations used in the existing methods appears to be consistent with the observed data, and, consequently, choice between the cluster LQAS methods is not straightforward. Further research should attempt to characterize clustering patterns in specific applications and provide suggestions for best-practice cluster LQAS designs on a setting-specific basis.

  2. The results of experimental studies of VLF-ULF electromagnetic emission by rock samples due to mechanical action

    Science.gov (United States)

    Panfilov, A. A.

    2014-06-01

    The paper presents the results of laboratory experiments on electromagnetic emissions excitation (the electric component of electromagnetic fields) by rock samples due to different forms of mechanical stress applications. It was shown that samples generate electric impulses with different spectra when the impact action, gradual loading or dynamic friction is applied. It was ascertained that level and spectral compositions of signals, generated by rock samples, change with an increasing number of hits. It was found that strong electromagnetic signals, generated while rock samples were fracturing, were accompanied by repetitive weak but perceptible variations in the electric field intensity in short frequency ranges.

  3. Salt Block II: description and results

    International Nuclear Information System (INIS)

    Hohlfelder, J.J.

    1980-06-01

    A description of and results from the Salt Block II experiment, which involved the heating of and measurement of water transport within a large sample of rock salt, are presented. These results include the measurement of water released into a heated borehole in the sample as well as measured temperatures within the salt. Measured temperatures are compared with the results of a mathematical model of the experiment

  4. Implicit Leadership Theory: Are Results Generalizable from Student to Professional Samples?

    Science.gov (United States)

    Singer, Ming

    1990-01-01

    Explores whether student subjects' implicit leadership theories are generalizable to professional subjects. Samples consisted of 220 undergraduates and 152 government employees in New Zealand. Finds the mean importance ratings were similar for the 2 samples, except students placed greater importance on factors beyond individual control. (DB)

  5. Treating Anxiety Disorders in Inner City Schools: Results from a Pilot Randomized Controlled Trial Comparing CBT and Usual Care

    Science.gov (United States)

    Ginsburg, Golda S.; Becker, Kimberly D.; Drazdowski, Tess K.; Tein, Jenn-Yun

    2012-01-01

    Background: The effectiveness of cognitive-behavioral treatment (CBT) in inner city schools, when delivered by novice CBT clinicians, and compared to usual care (UC), is unknown. Objective: This pilot study addressed this issue by comparing a modular CBT for anxiety disorders to UC in a sample of 32 volunteer youth (mean age 10.28 years, 63%…

  6. Headspace vapor characterization of Hanford waste tank 241-B-107: Results from samples collected on 7/23/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-B-107 (Tank B-107) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwestern National Laboratory (PNNL). A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in a table. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples are also listed in the same table. Detailed descriptions of the analytical results appear in the appendices

  7. Headspace vapor characterization of Hanford waste tank 241-S-106: Results from samples collected on 06/13/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-S-106 (Tank S-106) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in a table. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples are also listed in the same table. Detailed descriptions of the analytical results appear in the appendices

  8. Vapor space characterization of Waste Tank 241-TY-104: Results from samples collected on 4/27/95

    International Nuclear Information System (INIS)

    Klinger, G.S.; Olsen, K.B.; Clauss, T.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-TY-104 (referred to as Tank TY-104). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 8 were observed above the 5-ppbv reporting cutoff. Five tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 94% of the total organic components in Tank TY-104. Nitrous oxide (N 2 O) was the only permanent gas detected in the tank-headspace samples. Tank TY-104 is on the Ferrocyanide Watch List

  9. Vapor space characterization of Waste Tank 241-U-105: Results from samples collected on 2/24/95

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Ligotke, M.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-U-105 (referred to as Tank U-105). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, six were observed above the 5-ppbv reporting cutoff. Three tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. All nine of the organic analytes identified are listed in Table 1 and account for 100% of the total organic components in Tank U-105. Nitrous oxide (N 2 O) was the only permanent gas detected in the tank-headspace sample. Tank U-105 is on the Hydrogen Watch List

  10. Vapor space characterization of waste Tank 241-SX-103: Results from samples collected on 3/23/95

    International Nuclear Information System (INIS)

    Ligotke, M.W.; Clauss, T.W.; Pool, K.H.; McVeety, B.D.; Klinger, G.S.; Olsen, K.B.; Bredt, O.P.; Fruchter, J.S.; Goheen, S.C.

    1995-11-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage tank 241-SX-103 (referred to as Tank SX-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water vapor (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, two were observed above the 5-ppbv reporting cutoff. Two tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The four organic analytes identified are listed in Table 1 and account for approximately 100% of the total organic components in Tank SX-103. Carbon dioxide (CO 2 ) was the only permanent gas detected in the tank-headspace samples. Tank SX-103 is on the Hydrogen Watch List

  11. Implementing Generalized Additive Models to Estimate the Expected Value of Sample Information in a Microsimulation Model: Results of Three Case Studies.

    Science.gov (United States)

    Rabideau, Dustin J; Pei, Pamela P; Walensky, Rochelle P; Zheng, Amy; Parker, Robert A

    2018-02-01

    The expected value of sample information (EVSI) can help prioritize research but its application is hampered by computational infeasibility, especially for complex models. We investigated an approach by Strong and colleagues to estimate EVSI by applying generalized additive models (GAM) to results generated from a probabilistic sensitivity analysis (PSA). For 3 potential HIV prevention and treatment strategies, we estimated life expectancy and lifetime costs using the Cost-effectiveness of Preventing AIDS Complications (CEPAC) model, a complex patient-level microsimulation model of HIV progression. We fitted a GAM-a flexible regression model that estimates the functional form as part of the model fitting process-to the incremental net monetary benefits obtained from the CEPAC PSA. For each case study, we calculated the expected value of partial perfect information (EVPPI) using both the conventional nested Monte Carlo approach and the GAM approach. EVSI was calculated using the GAM approach. For all 3 case studies, the GAM approach consistently gave similar estimates of EVPPI compared with the conventional approach. The EVSI behaved as expected: it increased and converged to EVPPI for larger sample sizes. For each case study, generating the PSA results for the GAM approach required 3 to 4 days on a shared cluster, after which EVPPI and EVSI across a range of sample sizes were evaluated in minutes. The conventional approach required approximately 5 weeks for the EVPPI calculation alone. Estimating EVSI using the GAM approach with results from a PSA dramatically reduced the time required to conduct a computationally intense project, which would otherwise have been impractical. Using the GAM approach, we can efficiently provide policy makers with EVSI estimates, even for complex patient-level microsimulation models.

  12. Comparative study of bedside and laboratory measurements of hemoglobin.

    Science.gov (United States)

    Krenzischek, D A; Tanseco, F V

    1996-11-01

    The purpose of this study was to examine the effects of variations in technique on measurements of hemoglobin level done at the bedside and to compare these results with laboratory measurements of hemoglobin. In accordance with hospital policy, procedure, and protocol, various techniques were used to obtain samples of capillary and venous blood and of blood from arterial and central venous catheters. Levels of hemoglobin were measured at the bedside and in the laboratory, and the results were compared. The Johns Hopkins Hospital adult postanesthesia care unit. A total of 187 blood samples were obtained from 62 adults who had undergone general surgery. Group I comprised 20 subjects with capillary and venous blood samples. Group II comprised 21 subjects with arterial blood samples. Group III comprised 21 subjects with central venous blood samples. The results showed that the amount of blood to be discarded before obtaining samples of arterial and central venous blood need not be any larger than double the dead space of the catheter, and that shaking the blood sample for 10 seconds was sufficient to mix the sample before measurement of hemoglobin levels. Results of bedside and laboratory measurements of hemoglobin level were comparable. Bedside measurement of hemoglobin increases efficiency in patient care, decreases risk of blood-transmitted infection for staff, and decreases cost to the patient. However, the persons who perform the assay must be responsible in adhering to the standard of practice to minimize errors in the measurements.

  13. Human glioblastoma-associated microglia/monocytes express a distinct RNA profile compared to human control and murine samples.

    Science.gov (United States)

    Szulzewsky, Frank; Arora, Sonali; de Witte, Lot; Ulas, Thomas; Markovic, Darko; Schultze, Joachim L; Holland, Eric C; Synowitz, Michael; Wolf, Susanne A; Kettenmann, Helmut

    2016-08-01

    Glioblastoma (GBM) is the most aggressive brain tumor in adults. It is strongly infiltrated by microglia and peripheral monocytes that support tumor growth. In the present study we used RNA sequencing to compare the expression profile of CD11b(+) human glioblastoma-associated microglia/monocytes (hGAMs) to CD11b(+) microglia isolated from non-tumor samples. Hierarchical clustering and principal component analysis showed a clear separation of the two sample groups and we identified 334 significantly regulated genes in hGAMs. In comparison to human control microglia hGAMs upregulated genes associated with mitotic cell cycle, cell migration, cell adhesion, and extracellular matrix organization. We validated the expression of several genes associated with extracellular matrix organization in samples of human control microglia, hGAMs, and the hGAMs-depleted fraction via qPCR. The comparison to murine GAMs (mGAMs) showed that both cell populations share a significant fraction of upregulated transcripts compared with their respective controls. These genes were mostly related to mitotic cell cycle. However, in contrast to murine cells, human GAMs did not upregulate genes associated to immune activation. Comparison of human and murine GAMs expression data to several data sets of in vitro-activated human macrophages and murine microglia showed that, in contrast to mGAMs, hGAMs share a smaller overlap to these data sets in general and in particular to cells activated by proinflammatory stimulation with LPS + INFγ or TNFα. Our findings provide new insights into the biology of human glioblastoma-associated microglia/monocytes and give detailed information about the validity of murine experimental models. GLIA 2016 GLIA 2016;64:1416-1436. © 2016 Wiley Periodicals, Inc.

  14. Soil sampling strategies: Evaluation of different approaches

    Energy Technology Data Exchange (ETDEWEB)

    De Zorzi, Paolo [Agenzia per la Protezione dell' Ambiente e per i Servizi Tecnici (APAT), Servizio Metrologia Ambientale, Via di Castel Romano, 100-00128 Roma (Italy)], E-mail: paolo.dezorzi@apat.it; Barbizzi, Sabrina; Belli, Maria [Agenzia per la Protezione dell' Ambiente e per i Servizi Tecnici (APAT), Servizio Metrologia Ambientale, Via di Castel Romano, 100-00128 Roma (Italy); Mufato, Renzo; Sartori, Giuseppe; Stocchero, Giulia [Agenzia Regionale per la Prevenzione e Protezione dell' Ambiente del Veneto, ARPA Veneto, U.O. Centro Qualita Dati, Via Spalato, 14-36045 Vicenza (Italy)

    2008-11-15

    The National Environmental Protection Agency of Italy (APAT) performed a soil sampling intercomparison, inviting 14 regional agencies to test their own soil sampling strategies. The intercomparison was carried out at a reference site, previously characterised for metal mass fraction distribution. A wide range of sampling strategies, in terms of sampling patterns, type and number of samples collected, were used to assess the mean mass fraction values of some selected elements. The different strategies led in general to acceptable bias values (D) less than 2{sigma}, calculated according to ISO 13258. Sampling on arable land was relatively easy, with comparable results between different sampling strategies.

  15. Soil sampling strategies: Evaluation of different approaches

    International Nuclear Information System (INIS)

    De Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Mufato, Renzo; Sartori, Giuseppe; Stocchero, Giulia

    2008-01-01

    The National Environmental Protection Agency of Italy (APAT) performed a soil sampling intercomparison, inviting 14 regional agencies to test their own soil sampling strategies. The intercomparison was carried out at a reference site, previously characterised for metal mass fraction distribution. A wide range of sampling strategies, in terms of sampling patterns, type and number of samples collected, were used to assess the mean mass fraction values of some selected elements. The different strategies led in general to acceptable bias values (D) less than 2σ, calculated according to ISO 13258. Sampling on arable land was relatively easy, with comparable results between different sampling strategies

  16. Soil sampling strategies: evaluation of different approaches.

    Science.gov (United States)

    de Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Mufato, Renzo; Sartori, Giuseppe; Stocchero, Giulia

    2008-11-01

    The National Environmental Protection Agency of Italy (APAT) performed a soil sampling intercomparison, inviting 14 regional agencies to test their own soil sampling strategies. The intercomparison was carried out at a reference site, previously characterised for metal mass fraction distribution. A wide range of sampling strategies, in terms of sampling patterns, type and number of samples collected, were used to assess the mean mass fraction values of some selected elements. The different strategies led in general to acceptable bias values (D) less than 2sigma, calculated according to ISO 13258. Sampling on arable land was relatively easy, with comparable results between different sampling strategies.

  17. Comet coma sample return instrument

    Science.gov (United States)

    Albee, A. L.; Brownlee, Don E.; Burnett, Donald S.; Tsou, Peter; Uesugi, K. T.

    1994-01-01

    The sample collection technology and instrument concept for the Sample of Comet Coma Earth Return Mission (SOCCER) are described. The scientific goals of this Flyby Sample Return are to return to coma dust and volatile samples from a known comet source, which will permit accurate elemental and isotopic measurements for thousands of individual solid particles and volatiles, detailed analysis of the dust structure, morphology, and mineralogy of the intact samples, and identification of the biogenic elements or compounds in the solid and volatile samples. Having these intact samples, morphologic, petrographic, and phase structural features can be determined. Information on dust particle size, shape, and density can be ascertained by analyzing penetration holes and tracks in the capture medium. Time and spatial data of dust capture will provide understanding of the flux dynamics of the coma and the jets. Additional information will include the identification of cosmic ray tracks in the cometary grains, which can provide a particle's process history and perhaps even the age of the comet. The measurements will be made with the same equipment used for studying micrometeorites for decades past; hence, the results can be directly compared without extrapolation or modification. The data will provide a powerful and direct technique for comparing the cometary samples with all known types of meteorites and interplanetary dust. This sample collection system will provide the first sample return from a specifically identified primitive body and will allow, for the first time, a direct method of matching meteoritic materials captured on Earth with known parent bodies.

  18. Sample Results From The Interim Salt Disposition Program Macrobatch 7 Tank 21H Qualification Samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B.; Washington, A. L. II

    2013-08-08

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 7 for the Interim Salt Disposition Program (ISDP). An ARP and several ESS tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP/MCU. No issues with the projected Salt Batch 7 strategy are identified, other than the presence of visible quantities of dark colored solids. A demonstration of the monosodium titanate (0.2 g/L) removal of strontium and actinides provided acceptable 4 hour average decontamination factors for Pu and Sr of 3.22 and 18.4, respectively. The Four ESS tests also showed acceptable behavior with distribution ratios (D(Cs)) values of 15.96, 57.1, 58.6, and 65.6 for the MCU, cold blend, hot blend, and Next Generation Solvent (NGS), respectively. The predicted value for the MCU solvent was 13.2. Currently, there are no models that would allow a prediction of extraction behavior for the other three solvents. SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed. While no outstanding issues were noted, the presence of solids in the samples should be investigated in future work. It is possible that the solids may represent a potential reservoir of material (such as potassium) that could have an impact on MCU performance if they were to dissolve back into the feed solution. This salt batch is intended to be the first batch to be processed through MCU entirely using the new NGS-MCU solvent.

  19. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies

    OpenAIRE

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung-Hoi

    2016-01-01

    Background ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. Methods In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to...

  20. Particulate organic nitrates: Sampling and night/day variation

    DEFF Research Database (Denmark)

    Nielsen, T.; Platz, J.; Granby, K.

    1998-01-01

    Atmospheric day and night concentrations of particulate organic nitrates (PON) and several other air pollutants were measured in the summer 1995 over an open-land area in Denmark. The sampling of PON was evaluated comparing 24 h samples with two sets of 12 h samples. These results indicate...... that the observed low contribution of PON to NO, is real and not the result of an extensive loss during the sampling. Empirical relationships between the vapour pressure and chemical formula of organic compounds were established in order to evaluate the gas/particle distribution of organic nitrates. A positive...

  1. Alpha Matting with KL-Divergence Based Sparse Sampling.

    Science.gov (United States)

    Karacan, Levent; Erdem, Aykut; Erdem, Erkut

    2017-06-22

    In this paper, we present a new sampling-based alpha matting approach for the accurate estimation of foreground and background layers of an image. Previous sampling-based methods typically rely on certain heuristics in collecting representative samples from known regions, and thus their performance deteriorates if the underlying assumptions are not satisfied. To alleviate this, we take an entirely new approach and formulate sampling as a sparse subset selection problem where we propose to pick a small set of candidate samples that best explains the unknown pixels. Moreover, we describe a new dissimilarity measure for comparing two samples which is based on KLdivergence between the distributions of features extracted in the vicinity of the samples. The proposed framework is general and could be easily extended to video matting by additionally taking temporal information into account in the sampling process. Evaluation on standard benchmark datasets for image and video matting demonstrates that our approach provides more accurate results compared to the state-of-the-art methods.

  2. A comparative study of 232Th and 238U activity estimation in soil samples by gamma spectrometry and Neutron Activation Analysis (NAA) technique

    International Nuclear Information System (INIS)

    Rekha, A.K.; Anilkumar, S.; Narayani, K.; Babu, D.A.R.

    2012-01-01

    Radioactivity in the environment is mainly due to the naturally occurring radionuclides like uranium, thorium with their daughter products and potassium. Even though Gamma spectrometry is the most commonly used non destructive method for the quantification of these naturally occurring radionuclides, Neutron Activation Analysis (NAA), a well established analytical technique, can also be used. But the NAA technique is a time consuming process and needs proper standards, proper sample preparation etc. In this paper, the 232 Th and 238 U activity estimated using gamma ray spectrometry and NAA technique are compared. In the case of direct gamma spectrometry method, the samples were analysed after sealing in a 250 ml container. Whereas for the NAA, about 300 mg of each sample, after irradiation were subjected to gamma spectrometry. The 238 U and 232 Th activities (in Bq/kg) in samples were estimated after the proper efficiency correction and were compared. The estimated activities by these two methods are in good agreement. The variation in 238 U and 232 Th activity values are within ± 15% which are acceptable for environmental samples

  3. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison

    Science.gov (United States)

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practica...

  4. Autosomal SNP typing of forensic samples with the GenPlex(TM) HID System: Results of a collaborative study

    DEFF Research Database (Denmark)

    Tomas, C.; Axler-DiPerte, G.; Budimlija, Z.M.

    2011-01-01

    in Europe and 5 in the US) in order to test the robustness and reliability of the GenPlex(TM) HID System on forensic samples. Three samples with partly degraded DNA and 10 samples with low amounts of DNA were analyzed in duplicates using various amounts of DNA. In order to compare the performance of the Gen......Plex(TM) HID System with the most commonly used STR kits, 500 pg of partly degraded DNA from three samples was typed by the laboratories using one or more STR kits. The median SNP typing success rate was 92.3% with 500 pg of partly degraded DNA. Three of the fourteen laboratories counted for more than two...... was the least successful. With the exception of the MiniFiler(TM) kit (AB), GenPlex(TM) HID performed better than five other tested STR kits. When partly degraded DNA was analyzed, GenPlex(TM) HID showed a very low mean mach probability, while all STR kits except MiniFiler(TM) had very limited discriminatory...

  5. Comparing different post-mortem human samples as DNA sources for downstream genotyping and identification.

    Science.gov (United States)

    Calacal, Gayvelline C; Apaga, Dame Loveliness T; Salvador, Jazelyn M; Jimenez, Joseph Andrew D; Lagat, Ludivino J; Villacorta, Renato Pio F; Lim, Maria Cecilia F; Fortun, Raquel D R; Datar, Francisco A; De Ungria, Maria Corazon A

    2015-11-01

    PowerPlex(®)21 and PowerPlexY(®)23 systems and analyzed using the AB3500 Genetic Analyzer and the GeneMapper(®) ID-X v.1.2 software. PCR inhibitors were consistently detected in bone marrow, muscle tissue, rib and vertebra samples. Amplifiable DNA was obtained in a majority of the samples analyzed. DNA recovery from 0.1g biological material was adequate for successful genotyping of most of the non-bone and bone samples. Complete DNA profiles were generated from bone marrow, femur, metatarsal and patella with 0.1 ng DNA template. Using 0.5 ng DNA template resulted in increased allele recovery and improved intra- and inter-locus peak balance. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

    Energy Technology Data Exchange (ETDEWEB)

    Veltri, Andrea, E-mail: andrea.veltri@unito.it; Busso, Marco; Sardo, Diego; Angelino, Valeria; Priola, Adriano M. [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Novello, Silvia [University of Torino, Department of Oncology, San Luigi Gonzaga Hospital (Italy); Barba, Matteo [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Gatti, Gaia; Righi, Luisella [University of Torino, Department of Pathology, San Luigi Gonzaga Hospital (Italy)

    2017-06-15

    PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.

  7. Analysis of monazite samples

    International Nuclear Information System (INIS)

    Kartiwa Sumadi; Yayah Rohayati

    1996-01-01

    The 'monazit' analytical program has been set up for routine work of Rare Earth Elements analysis in the monazite and xenotime minerals samples. Total relative error of the analysis is very low, less than 2.50%, and the reproducibility of counting statistic and stability of the instrument were very excellent. The precision and accuracy of the analytical program are very good with the maximum percentage relative are 5.22% and 1.61%, respectively. The mineral compositions of the 30 monazite samples have been also calculated using their chemical constituents, and the results were compared to the grain counting microscopic analysis

  8. Solvent Hold Tank Sample Results for MCU-16-701-702-703: May 2016 Monthly Sample and MCU-16-710-711-712: May 2016 Superwashed Sample

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-08-30

    The Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-701, MCU-16-702 and MCU-16-703), pulled on 05/23/2016, and another set of SHT samples (MCU-16-710, MCU-16-711, and MCU-16-712) were pulled on 05/28/2016 after the solvent was superwashed with 300 mM sodium hydroxide for analysis. Samples MCU-16-701, MCU-16-702, and MCU-16-703 were combined into one sample (MCU-16-701-702-703) and samples MCU-16-710, MCU- 16-711, and MCU-16-712 were combined into one sample (MCU-16-710-711-712). Of the two composite samples MCU-16-710-711-712 represents the current chemical state of the solvent at MCU. All analytical conclusions are based on the chemical analysis of MCU-16-710-711-712. There were no chemical differences between MCU-16-701-702-703 and superwashed MCU-16-710-711-712. Analysis of the composited sample MCU-16-710-712-713 indicated the Isopar™L concentration is above its nominal level (102%). The modifier (CS-7SB) is 16% below its nominal concentration, while the TiDG and MaxCalix concentrations are at and above their nominal concentrations, respectively. The TiDG level has begun to decrease, and it is 7% below its nominal level as of May 28, 2016. Based on this current analysis, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

  9. Radiological results for samples collected on paired glass- and cellulose-fiber filters at the Sandia complex, Tonopah Test Range, Nevada

    International Nuclear Information System (INIS)

    Mizell, Steve A.; Shadel, Craig A.

    2016-01-01

    Airborne particulates are collected at U.S. Department of Energy sites that exhibit radiological contamination on the soil surface to help assess the potential for wind to transport radionuclides from the contamination sites. Collecting these samples was originally accomplished by drawing air through a cellulose-fiber filter. These filters were replaced with glass-fiber filters in March 2011. Airborne particulates were collected side by side on the two filter materials between May 2013 and May 2014. Comparisons of the sample mass and the radioactivity determinations for the side-by-side samples were undertaken to determine if the change in the filter medium produced significant results. The differences in the results obtained using the two filter types were assessed visually by evaluating the time series and correlation plots and statistically by conducting a nonparametric matched-pair sign test. Generally, the glass-fiber filters collect larger samples of particulates and produce higher radioactivity values for the gross alpha, gross beta, and gamma spectroscopy analyses. However, the correlation between the radioanalytical results for the glass-fiber filters and the cellulose-fiber filters was not strong enough to generate a linear regression function to estimate the glass-fiber filter sample results from the cellulose-fiber filter sample results.

  10. Vapor space characterization of Waste Tank 241-U-107: Results from samples collected on 2/17/95

    International Nuclear Information System (INIS)

    McVeety, B.D.; Clauss, T.W.; Ligotke, M.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-U-107 (referred to as Tank U-107). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 10 were observed above the 5-ppbv reporting cutoff. Sixteen organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv, and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 88% of the total organic components in Tank U-107. Nitrous oxide (N 2 O) was the only permanent gas detected in the tank-headspace samples. Tank U-107 is on the Organic and the Hydrogen Watch Lists

  11. Toward cost-efficient sampling methods

    Science.gov (United States)

    Luo, Peng; Li, Yongli; Wu, Chong; Zhang, Guijie

    2015-09-01

    The sampling method has been paid much attention in the field of complex network in general and statistical physics in particular. This paper proposes two new sampling methods based on the idea that a small part of vertices with high node degree could possess the most structure information of a complex network. The two proposed sampling methods are efficient in sampling high degree nodes so that they would be useful even if the sampling rate is low, which means cost-efficient. The first new sampling method is developed on the basis of the widely used stratified random sampling (SRS) method and the second one improves the famous snowball sampling (SBS) method. In order to demonstrate the validity and accuracy of two new sampling methods, we compare them with the existing sampling methods in three commonly used simulation networks that are scale-free network, random network, small-world network, and also in two real networks. The experimental results illustrate that the two proposed sampling methods perform much better than the existing sampling methods in terms of achieving the true network structure characteristics reflected by clustering coefficient, Bonacich centrality and average path length, especially when the sampling rate is low.

  12. Short Communication: Testosterone Measured with an Automatic Immunoassay Compares Reasonbly Well to Results Obtained by LC-MS/MS

    DEFF Research Database (Denmark)

    Knudsen, Cindy Søndersø; Højskov, Carsten Schriver; Møller, Holger Jon

    2016-01-01

    Background: Previous studies have reported problems measuring testosterone with immunological assays. Here we explore an automatic second generation immunoassay compared to a LC-MS/MS method. Methods: We collected blood samples from 76 women and measured testosterone, progesterone, gender...... hormonebinding globulin (SHBG), and albumin employing Cobas e601/c501. Testosterone, androstenedione (andro), dehydroepiandrosterone sulphate (DHEAS), and 17-hydroxyprogesterone (17-OHP) concentrations were measured employing LC-MS/MS. We evaluated the difference between testosterone measured by the two methods...... and examined the potential interference from the selected steroids and bindings proteins. Results: Testosterone concentrations measured by the two methods yielded: Cobas e601 = 1.240 x (LC-MS/MS) - 0.197, r = 0.84, for testosterone concentrations between 0.22 - 4.9 nmol/L. A positive correlation was observed...

  13. Analytical results for 544 water samples collected in the Attean Quartz Monzonite in the vicinity of Jackman, Maine

    Science.gov (United States)

    Ficklin, W.H.; Nowlan, G.A.; Preston, D.J.

    1983-01-01

    Water samples were collected in the vicinity of Jackman, Maine as a part of the study of the relationship of dissolved constituents in water to the sediments subjacent to the water. Each sample was analyzed for specific conductance, alkalinity, acidity, pH, fluoride, chloride, sulfate, phosphate, nitrate, sodium, potassium, calcium, magnesium, and silica. Trace elements determined were copper, zinc, molybdenum, lead, iron, manganese, arsenic, cobalt, nickel, and strontium. The longitude and latitude of each sample location and a sample site map are included in the report as well as a table of the analytical results.

  14. A comprehensive summary of the ORNL Groundwater Compliance and Surveillance Sampling Results Software System

    International Nuclear Information System (INIS)

    Loffman, R.S.

    1995-01-01

    Groundwater compliance and surveillance activities are conducted at ORNL to fulfill federal and state requirements for environmental monitoring. Information management is an important aspect of this and encompasses many activities which usually have spcific time frames and schedules. In addition to fulfilling these immediate requirements, the results for the monitoring activities are also used to determine the need for environmental remediation. ORNL performs this groundwater results data management and reporting utilizing a group of SAS reg-sign applications and tools which provide the ability to track samples, capture field measurements, verify and validate result data, manage data, and report results in a variety of ways and in a timely manner. This paper provides a comprehensive summary of these applications and tools

  15. Prevalence of dementia-associated disability among Chinese older adults: results from a national sample survey.

    Science.gov (United States)

    Li, Ning; Zhang, Lei; Du, Wei; Pang, Lihua; Guo, Chao; Chen, Gong; Zheng, Xiaoying

    2015-03-01

    Due to rapid population aging and a tidal wave of dementia, dementia has become an urgent public health issue in China. Few large-scale surveys on dementia have been conducted in China and little was known about the magnitude of dysfunction and disability caused by dementia. In this study, using national sample survey data, we aimed to describe the prevalence rate of dementia-associated disability, its associated factors, and daily activities and social functions of people with dementia-associated disability in Chinese older adults. We used the second China National Sample Survey on Disability, comprising 2,526,145 persons from 771,797 households. Identification for dementia was based on consensus manuals. Standard weighting procedures were used to construct sample weights considering the multistage stratified cluster sampling survey scheme. Population weighted numbers, weighted prevalence, and the odd ratios (ORs) were calculated. The prevalence rate of dementia-associated disability was 4.64% (95% CI: 4.26-5.01) and it accounted for 41.03% of mental disability among Chinese older adults. Urban residence (OR: 1.33 [1.12-1.57]), older age (80+ years) (OR: 4.12 [3.38-.03]), illiteracy (OR: 1.79 [1.27-2.53]), and currently not married (OR: 1.15 [1.00-1.32]) were associated with increased risk of dementia-associated disability. Compared with those with mental disability of other causes and those with other types of disabilities, older adults with dementia-asscoiated disability were more likely to have severe or extreme difficulty in daily activities and social functions. Countermeasures are warranted to obtain a more precise overview of dementia in China, and strategies on enhancing early identification, treatment, and rehabilitation should be developed for people with dementia. Copyright © 2015 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  16. Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

    Science.gov (United States)

    Chinn, Tori N.; Lee, Anthony K.; Boone, Travis D.; Tan, Ming X.; Chin, Matthew M.; McCutcheon, Griffin C.; Horne, Mera F.; Padgen, Michael R.; Blaich, Justin T.; Forgione, Joshua B.; hide

    2017-01-01

    We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo

  17. Comparative exploration of hydrogen sulfide and water transmembrane free energy surfaces via orthogonal space tempering free energy sampling.

    Science.gov (United States)

    Lv, Chao; Aitchison, Erick W; Wu, Dongsheng; Zheng, Lianqing; Cheng, Xiaolin; Yang, Wei

    2016-03-05

    Hydrogen sulfide (H2 S), a commonly known toxic gas compound, possesses unique chemical features that allow this small solute molecule to quickly diffuse through cell membranes. Taking advantage of the recent orthogonal space tempering (OST) method, we comparatively mapped the transmembrane free energy landscapes of H2 S and its structural analogue, water (H2 O), seeking to decipher the molecular determinants that govern their drastically different permeabilities. As revealed by our OST sampling results, in contrast to the highly polar water solute, hydrogen sulfide is evidently amphipathic, and thus inside membrane is favorably localized at the interfacial region, that is, the interface between the polar head-group and nonpolar acyl chain regions. Because the membrane binding affinity of H2 S is mainly governed by its small hydrophobic moiety and the barrier height inbetween the interfacial region and the membrane center is largely determined by its moderate polarity, the transmembrane free energy barriers to encounter by this toxic molecule are very small. Moreover when H2 S diffuses from the bulk solution to the membrane center, the above two effects nearly cancel each other, so as to lead to a negligible free energy difference. This study not only explains why H2 S can quickly pass through cell membranes but also provides a practical illustration on how to use the OST free energy sampling method to conveniently analyze complex molecular processes. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  18. Mercury's plasma belt: hybrid simulations results compared to in-situ measurements

    Science.gov (United States)

    Hercik, D.; Travnicek, P. M.; Schriver, D.; Hellinger, P.

    2012-12-01

    The presence of plasma belt and trapped particles region in the Mercury's inner magnetosphere has been questionable due to small dimensions of the magnetosphere of Mercury compared to Earth, where these regions are formed. Numerical simulations of the solar wind interaction with Mercury's magnetic field suggested that such a structure could be found also in the vicinity of Mercury. These results has been recently confirmed also by MESSENGER observations. Here we present more detailed analysis of the plasma belt structure and quasi-trapped particle population characteristics and behaviour under different orientations of the interplanetary magnetic field.The plasma belt region is constantly supplied with solar wind protons via magnetospheric flanks and tail current sheet region. Protons inside the plasma belt region are quasi-trapped in the magnetic field of Mercury and perform westward drift along the planet. This region is well separated by a magnetic shell and has higher average temperatures and lower bulk proton current densities than surrounding area. On the day side the population exhibits loss cone distribution function matching the theoretical loss cone angle. Simulations results are also compared to in-situ measurements acquired by MESSENGER MAG and FIPS instruments.

  19. XCluSim: a visual analytics tool for interactively comparing multiple clustering results of bioinformatics data

    Science.gov (United States)

    2015-01-01

    Background Though cluster analysis has become a routine analytic task for bioinformatics research, it is still arduous for researchers to assess the quality of a clustering result. To select the best clustering method and its parameters for a dataset, researchers have to run multiple clustering algorithms and compare them. However, such a comparison task with multiple clustering results is cognitively demanding and laborious. Results In this paper, we present XCluSim, a visual analytics tool that enables users to interactively compare multiple clustering results based on the Visual Information Seeking Mantra. We build a taxonomy for categorizing existing techniques of clustering results visualization in terms of the Gestalt principles of grouping. Using the taxonomy, we choose the most appropriate interactive visualizations for presenting individual clustering results from different types of clustering algorithms. The efficacy of XCluSim is shown through case studies with a bioinformatician. Conclusions Compared to other relevant tools, XCluSim enables users to compare multiple clustering results in a more scalable manner. Moreover, XCluSim supports diverse clustering algorithms and dedicated visualizations and interactions for different types of clustering results, allowing more effective exploration of details on demand. Through case studies with a bioinformatics researcher, we received positive feedback on the functionalities of XCluSim, including its ability to help identify stably clustered items across multiple clustering results. PMID:26328893

  20. Risk Gambling and Personality: Results from a Representative Swedish Sample.

    Science.gov (United States)

    Sundqvist, Kristina; Wennberg, Peter

    2015-12-01

    The association between personality and gambling has been explored previously. However, few studies are based on representative populations. This study aimed at examining the association between risk gambling and personality in a representative Swedish population. A random Swedish sample (N = 19,530) was screened for risk gambling using the Lie/Bet questionnaire. The study sample (N = 257) consisted of those screening positive on Lie/Bet and completing a postal questionnaire about gambling and personality (measured with the NODS-PERC and the HP5i respectively). Risk gambling was positively correlated with Negative Affectivity (a facet of Neuroticism) and Impulsivity (an inversely related facet of Conscientiousness), but all associations were weak. When taking age and gender into account, there were no differences in personality across game preference groups, though preferred game correlated with level of risk gambling. Risk gamblers scored lower than the population norm data with respect to Negative Affectivity, but risk gambling men scored higher on Impulsivity. The association between risk gambling and personality found in previous studies was corroborated in this study using a representative sample. We conclude that risk and problem gamblers should not be treated as a homogeneous group, and prevention and treatment interventions should be adapted according to differences in personality, preferred type of game and the risk potential of the games.

  1. Discordant genotyping results using DNA isolated from anti-doping control urine samples.

    Science.gov (United States)

    Choong, Eva; Schulze, Jenny J; Ericsson, Magnus; Rane, Anders; Ekström, Lena

    2017-07-01

    The UGT2B17 gene deletion polymorphism is known to correlate to urinary concentration of testosterone-glucuronide and hence this genotype exerts a large impact on the testosterone/epitestosterone (T/E) ratio, a biomarker for testosterone doping. The objective of this study was to assess if DNA isolated from athletes' urine samples (n = 713) obtained in routine doping controls could be targeted for genotyping analysis for future integration in the athlete's passport. A control population (n = 21) including both urine and blood DNA was used for genotyping concordance test. Another aim was to study a large group (n = 596) of authentic elite athletes in respect of urinary steroid profile in relation to genetic variation. First we found that the genotype results when using urine-derived DNA did not correlate sufficiently with the genotype obtained from whole blood DNA. Secondly we found males with one or two UGT2B17 alleles had higher T/E (mean 1.63 ± 0.93) than females (mean 1.28 ± 1.08), p˂0.001. Unexpectedly, we found that several male del/del athletes in power sports had a T/E ˃1. If men in power sport exert a different urinary steroid profile needs to be further investigated. The other polymorphisms investigated in the CYP17A1, UGT2B7 and UGT2B15 genes did not show any associations with testosterone and epitestosterone concentrations. Our results show that genotyping using urine samples according to our method is not useful in an anti-doping setting. Instead, it is of importance for the anti-doping test programs to include baseline values in the ABP to minimize any putative impact of genotype. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Method validation in plasma source optical emission spectroscopy (ICP-OES) - From samples to results

    International Nuclear Information System (INIS)

    Pilon, Fabien; Vielle, Karine; Birolleau, Jean-Claude; Vigneau, Olivier; Labet, Alexandre; Arnal, Nadege; Adam, Christelle; Camilleri, Virginie; Amiel, Jeanine; Granier, Guy; Faure, Joel; Arnaud, Regine; Beres, Andre; Blanchard, Jean-Marc; Boyer-Deslys, Valerie; Broudic, Veronique; Marques, Caroline; Augeray, Celine; Bellefleur, Alexandre; Bienvenu, Philippe; Delteil, Nicole; Boulet, Beatrice; Bourgarit, David; Brennetot, Rene; Fichet, Pascal; Celier, Magali; Chevillotte, Rene; Klelifa, Aline; Fuchs, Gilbert; Le Coq, Gilles; Mermet, Jean-Michel

    2017-01-01

    Even though ICP-OES (Inductively Coupled Plasma - Optical Emission Spectroscopy) is now a routine analysis technique, requirements for measuring processes impose a complete control and mastering of the operating process and of the associated quality management system. The aim of this (collective) book is to guide the analyst during all the measurement validation procedure and to help him to guarantee the mastering of its different steps: administrative and physical management of samples in the laboratory, preparation and treatment of the samples before measuring, qualification and monitoring of the apparatus, instrument setting and calibration strategy, exploitation of results in terms of accuracy, reliability, data covariance (with the practical determination of the accuracy profile). The most recent terminology is used in the book, and numerous examples and illustrations are given in order to a better understanding and to help the elaboration of method validation documents

  3. Tank Vapor Characterization Project: Vapor space characterization of waste Tank A-101, Results from samples collected on June 8, 1995

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; McVeety, B.D.; Evans, J.C.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Ligotke, M.W.

    1995-11-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-A-101 (Tank A-101) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank-farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the results is listed in Table 1. Detailed descriptions of the analytical results appear in the text

  4. Fitting models of continuous trait evolution to incompletely sampled comparative data using approximate Bayesian computation.

    Science.gov (United States)

    Slater, Graham J; Harmon, Luke J; Wegmann, Daniel; Joyce, Paul; Revell, Liam J; Alfaro, Michael E

    2012-03-01

    In recent years, a suite of methods has been developed to fit multiple rate models to phylogenetic comparative data. However, most methods have limited utility at broad phylogenetic scales because they typically require complete sampling of both the tree and the associated phenotypic data. Here, we develop and implement a new, tree-based method called MECCA (Modeling Evolution of Continuous Characters using ABC) that uses a hybrid likelihood/approximate Bayesian computation (ABC)-Markov-Chain Monte Carlo approach to simultaneously infer rates of diversification and trait evolution from incompletely sampled phylogenies and trait data. We demonstrate via simulation that MECCA has considerable power to choose among single versus multiple evolutionary rate models, and thus can be used to test hypotheses about changes in the rate of trait evolution across an incomplete tree of life. We finally apply MECCA to an empirical example of body size evolution in carnivores, and show that there is no evidence for an elevated rate of body size evolution in the pinnipeds relative to terrestrial carnivores. ABC approaches can provide a useful alternative set of tools for future macroevolutionary studies where likelihood-dependent approaches are lacking. © 2011 The Author(s). Evolution© 2011 The Society for the Study of Evolution.

  5. Network Sampling with Memory: A proposal for more efficient sampling from social networks

    Science.gov (United States)

    Mouw, Ted; Verdery, Ashton M.

    2013-01-01

    Techniques for sampling from networks have grown into an important area of research across several fields. For sociologists, the possibility of sampling from a network is appealing for two reasons: (1) A network sample can yield substantively interesting data about network structures and social interactions, and (2) it is useful in situations where study populations are difficult or impossible to survey with traditional sampling approaches because of the lack of a sampling frame. Despite its appeal, methodological concerns about the precision and accuracy of network-based sampling methods remain. In particular, recent research has shown that sampling from a network using a random walk based approach such as Respondent Driven Sampling (RDS) can result in high design effects (DE)—the ratio of the sampling variance to the sampling variance of simple random sampling (SRS). A high design effect means that more cases must be collected to achieve the same level of precision as SRS. In this paper we propose an alternative strategy, Network Sampling with Memory (NSM), which collects network data from respondents in order to reduce design effects and, correspondingly, the number of interviews needed to achieve a given level of statistical power. NSM combines a “List” mode, where all individuals on the revealed network list are sampled with the same cumulative probability, with a “Search” mode, which gives priority to bridge nodes connecting the current sample to unexplored parts of the network. We test the relative efficiency of NSM compared to RDS and SRS on 162 school and university networks from Add Health and Facebook that range in size from 110 to 16,278 nodes. The results show that the average design effect for NSM on these 162 networks is 1.16, which is very close to the efficiency of a simple random sample (DE=1), and 98.5% lower than the average DE we observed for RDS. PMID:24159246

  6. Language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik

    1998-01-01

    This article has two aims: [1] to present a revised version of the sampling method that was originally proposed in 1993 by Rijkhoff, Bakker, Hengeveld and Kahrel, and [2] to discuss a number of other approaches to language sampling in the light of our own method. We will also demonstrate how our...... sampling method is used with different genetic classifications (Voegelin & Voegelin 1977, Ruhlen 1987, Grimes ed. 1997) and argue that —on the whole— our sampling technique compares favourably with other methods, especially in the case of exploratory research....

  7. Final Report on the Analytical Results for Tank Farm Samples in Support of Salt Dissolution Evaluation

    International Nuclear Information System (INIS)

    Hobbs, D.T.

    1996-01-01

    Recent processing of dilute solutions through the 2H-Evaporator system caused dissolution of salt in Tank 38H, the concentrate receipt tank. This report documents analytical results for samples taken from this evaporator system

  8. Results from the interim salt disposition program macrobatch 10 tank 21H qualification samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Bannochie, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-02-23

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 10 for the Interim Salt Disposition Program (ISDP). This document reports characterization data on the samples of Tank 21H and fulfills the requirements of Deliverable 3 of the Technical Task Request (TTR). Further work will report the results of the Extraction-Scrub-Strip (ESS) testing (Task 5 of the TTR) using the Tank 21H material. Task 4 of the TTR (MST Strike) will not be completed for Salt Batch 10.

  9. Influence of a sampling review process for radiation oncology quality assurance in cooperative group clinical trials -- results of the Radiation Therapy Oncology Group (RTOG) analysis

    International Nuclear Information System (INIS)

    Martin, Linda A.; Krall, John M.; Curran, Walter J.; Leibel, Steven A.; Cox, James D.

    1995-01-01

    The Radiation Therapy Oncology Group (RTOG) designed a random sampling process and observed its influence upon radiotherapy review mechanisms in cooperative group clinical trials. The method of sampling cases for review was modeled from sampling techniques commonly used in pharmaceutical quality assurance programs, and applied to the initial (on-study) review of protocol cases. 'In control' (IC) status is defined for a given facility as the ability to meet minimum compliance standards. Upon achieving IC status, activation of the sampling process was linked to the rate of continued patient accrual for each participating institution in a given protocol. The sampling design specified that ≥ 30% cases not in compliance would be detected with 80% power. A total of 458 cases was analyzed for initial review findings in four RTOG Phase III protocols. Initial review findings were compared with retrospective (final) review results. Of the 458 cases analyzed, 370 underwent initial review at on-study, while 88 did not require review as they were enrolled from institutions that had demonstrated protocol compliance. In the group that had both initial and final review, (345(370)) (93%) were found to have followed the protocol or had a minor variation. Of the exempted cases, (79(88)) (90%) were found to be per protocol or a minor variant. The sampling process proved itself to be cost-effective and resulted in a noticeable reduction in the workload, thus providing an improved approach to resource allocation for the group. Continued evaluation of the sampling mechanism is appropriate as study designs and participants vary over time, and as more data become available to study. Further investigation of individual protocol compliance is appropriate to identify problems specific to new trial investigations

  10. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality

    Science.gov (United States)

    Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne

    2018-01-01

    Introduction Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. Materials and methods The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. Results The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. Conclusions The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in

  11. Non-destructive alpha-particle activation analysis of P, Cl, K and Ca in marine macro-alga samples using synthetic multielement reference material as comparative standard

    International Nuclear Information System (INIS)

    Iwata, Y.; Naitoh, H.; Suzuki, N.

    1992-01-01

    A Synthetic Reference Material (SyRM) composed with accurately known amounts of 12 elements has been prepared. The elemental composition of the SyRM is closely similar to that of marine macro-algae sample. The elemental composition of the SyRM was regulated by the starting materials used for the synthesis. The SyRM was used as a comparative standard for non-destructive alpha-particle activation analysis of marine macro-alga samples. P, Cl, K and Ca were determined simultaneously without correction for alpha range due to difference in the elemental composition between the analytical samples and the comparative standard. (author) 19 refs.; 4 tabs

  12. Comparative effectiveness and acceptability of home-based and clinic-based sampling methods for sexually transmissible infections screening in females aged 14-50 years: a systematic review and meta-analysis.

    Science.gov (United States)

    Odesanmi, Tolulope Y; Wasti, Sharada P; Odesanmi, Omolola S; Adegbola, Omololu; Oguntuase, Olubukola O; Mahmood, Sajid

    2013-12-01

    Home-based sampling is a strategy to enhance uptake of sexually transmissible infection (STI) screening. This review aimed to compare the screening uptake levels of home-based self-sampling and clinic-based specimen collection for STIs (chlamydia (Chlamydia trachomatis), gonorrhoea (Neisseria gonorrhoeae) and trichomoniasis) in females aged 14-50 years. Acceptability and effect on specimen quality were determined. Sixteen electronic databases were searched from inception to September 2012. Randomised controlled trials (RCTs) comparing the uptake levels of home-based self-sampling and clinic-based sampling for chlamydia, gonorrhoea and trichomoniasis in females aged 14-50 years were eligible for inclusion. The risk of bias in the trials was assessed. Risk ratios (RRs) for dichotomous outcomes were meta-analysed. Of 3065 papers, six studies with seven RCTs contributed to the final review. Compared with clinic-based methods, home-based screening increased uptake significantly (P=0.001-0.05) in five trials and was substantiated in a meta-analysis (RR: 1.55; 95% confidence interval: 1.30-1.85; P=0.00001) of two trials. In three trials, a significant preference for home-based testing (P=0.001-0.05) was expressed. No significant difference was observed in specimen quality. Sampling was rated as easy by a significantly higher number of women (P=0.01) in the clinic group in one trial. The review provides evidence that home-based testing results in greater uptake of STI screening in females (14-50 years) than clinic-based testing without compromising quality in the developed world. Home collection strategies should be added to clinic-based screening programs to enhance uptake.

  13. Akathisia: prevalence and risk factors in a community-dwelling sample of patients with schizophrenia. Results from the FACE-SZ dataset.

    Science.gov (United States)

    Berna, F; Misdrahi, D; Boyer, L; Aouizerate, B; Brunel, L; Capdevielle, D; Chereau, I; Danion, J M; Dorey, J M; Dubertret, C; Dubreucq, J; Faget, C; Gabayet, F; Lancon, C; Mallet, J; Rey, R; Passerieux, C; Schandrin, A; Schurhoff, F; Tronche, A M; Urbach, M; Vidailhet, P; Llorca, P M; Fond, G

    2015-12-01

    The main objective of this study was to determine the prevalence of akathisia in a community-dwelling sample of patients with schizophrenia, and to determine the effects of treatments and the clinical variables associated with akathisia. 372 patients with schizophrenia or schizoaffective disorder were systematically included in the network of FondaMental Expert Center for Schizophrenia and assessed with validated scales. Akathisia was measured with the Barnes Akathisia Scale (BAS). Ongoing psychotropic treatment was recorded. The global prevalence of akathisia (as defined by a score of 2 or more on the global akathisia subscale of the BAS) in our sample was 18.5%. Patients who received antipsychotic polytherapy were at higher risk of akathisia and this result remained significant (adjusted odd ratio=2.04, p=.025) after controlling the influence of age, gender, level of education, level of psychotic symptoms, substance use comorbidities, current administration of antidepressant, anticholinergic drugs, benzodiazepines, and daily-administered antipsychotic dose. The combination of second-generation antipsychotics was associated with a 3-fold risk of akathisia compared to second-generation antipsychotics used in monotherapy. Our results indicate that antipsychotic polytherapy should be at best avoided and suggest that monotherapy should be recommended in cases of akathisia. Long-term administration of benzodiazepines or anticholinergic drugs does not seem to be advisable in cases of akathisia, given the potential side effects of these medications. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Inter comparison of 90Sr and 137Cs contents in biologic samples and natural U in soil samples

    International Nuclear Information System (INIS)

    Liu Jianfen; Zeng Guangjian; Lu Xuequan

    2001-01-01

    The results of the 90 Sr and 137 Cs contents in biologic samples and the natural U in soil samples obtained in a joint effort by fourteen environmental radiation laboratories in the Chinese environmental protection system were analyzed and compared. Two kinds of biologic samples and one kind of soil samples were used for inter comparison. Of which, one kind of biologic samples (biologic powder samples) and the soil samples came from the IAEA samples were environmental and the reference values were known. The another kind of biologic samples were environmental tea-leaf that were taken from a tea garden near Hangzhou. The mean values obtained by all the joined laboratories was used as the reference. The inter comparison results were expressed in terms of the deviation from the reference value. It was found that the deviation of the 90 Sr and 137 Cs contents of biologic powder samples ranged from -15.4% to 26.5% and -15.0% to 0.4%, respectively. The deviation of the natural U content ranged from -25.5% to 7.3% for the soil samples. For the tea-leaf, the 90 Sr deviation was -22.7% to 19.1%, and the 137 Cs data had a relative large scatter with a ratio of the maximum and the minimum values being about 7. It was pointed out that the analysis results offered by different laboratories might have involved system errors

  15. Quantitative analysis of untreated bio-samples

    International Nuclear Information System (INIS)

    Sera, K.; Futatsugawa, S.; Matsuda, K.

    1999-01-01

    A standard-free method of quantitative analysis for untreated samples has been developed. For hair samples, measurements were performed by irradiating with a proton beam a few hairs as they are, and quantitative analysis was carried out by means of a standard-free method developed by ourselves. First, quantitative values of concentration of zinc were derived, then concentration of other elements was obtained by regarding zinc as an internal standard. As the result, values of concentration of sulphur for 40 samples agree well with the average value for a typical Japanese and also with each other within 20%, and validity of the present method could be confirmed. Accuracy was confirmed by comparing the results with those obtained by the usual internal standard method, too. For the purpose of a surface analysis of a bone sample, a very small incidence angle of the proton beam was used, so that both energy loss of the projectile and self-absorption of X-rays become negligible. As the result, consistent values of concentration for many elements were obtained by the standard-free method

  16. Validation of single-sample doubly labeled water method

    International Nuclear Information System (INIS)

    Webster, M.D.; Weathers, W.W.

    1989-01-01

    We have experimentally validated a single-sample variant of the doubly labeled water method for measuring metabolic rate and water turnover in a very small passerine bird, the verdin (Auriparus flaviceps). We measured CO 2 production using the Haldane gravimetric technique and compared these values with estimates derived from isotopic data. Doubly labeled water results based on the one-sample calculations differed from Haldane values by less than 0.5% on average (range -8.3 to 11.2%, n = 9). Water flux computed by the single-sample method differed by -1.5% on average from results for the same birds based on the standard, two-sample technique (range -13.7 to 2.0%, n = 9)

  17. A random cluster survey and a convenience sample give comparable estimates of immunity to vaccine preventable diseases in children of school age in Victoria, Australia.

    Science.gov (United States)

    Kelly, Heath; Riddell, Michaela A; Gidding, Heather F; Nolan, Terry; Gilbert, Gwendolyn L

    2002-08-19

    We compared estimates of the age-specific population immunity to measles, mumps, rubella, hepatitis B and varicella zoster viruses in Victorian school children obtained by a national sero-survey, using a convenience sample of residual sera from diagnostic laboratories throughout Australia, with those from a three-stage random cluster survey. When grouped according to school age (primary or secondary school) there was no significant difference in the estimates of immunity to measles, mumps, hepatitis B or varicella. Compared with the convenience sample, the random cluster survey estimated higher immunity to rubella in samples from both primary (98.7% versus 93.6%, P = 0.002) and secondary school students (98.4% versus 93.2%, P = 0.03). Despite some limitations, this study suggests that the collection of a convenience sample of sera from diagnostic laboratories is an appropriate sampling strategy to provide population immunity data that will inform Australia's current and future immunisation policies. Copyright 2002 Elsevier Science Ltd.

  18. Optimal grade control sampling practice in open-pit mining

    DEFF Research Database (Denmark)

    Engström, Karin; Esbensen, Kim Harry

    2017-01-01

    Misclassification of ore grades results in lost revenues, and the need for representative sampling procedures in open pit mining is increasingly important in all mining industries. This study evaluated possible improvements in sampling representativity with the use of Reverse Circulation (RC) drill...... sampling compared to manual Blast Hole (BH) sampling in the Leveäniemi open pit mine, northern Sweden. The variographic experiment results showed that sampling variability was lower for RC than for BH sampling. However, the total costs for RC drill sampling are significantly exceeding current costs...... for manual BH sampling, which needs to be compensated for by other benefits to motivate introduction of RC drilling. The main conclusion is that manual BH sampling can be fit-for-purpose in the studied open pit mine. However, with so many mineral commodities and mining methods in use globally...

  19. Y-STR analysis on DNA mixture samples--results of a collaborative project of the ENFSI DNA Working Group

    DEFF Research Database (Denmark)

    Parson, Walther; Niederstätter, Harald; Lindinger, Alexandra

    2008-01-01

    The ENFSI (European Network of Forensic Science Institutes) DNA Working Group undertook a collaborative project on Y-STR typing of DNA mixture samples that were centrally prepared and thoroughly tested prior to the shipment. Four commercial Y-STR typing kits (Y-Filer, Applied Biosystems, Foster C...... a laboratory-specific optimization process is indicated to reach a comparable sensitivity for the analysis of minute amounts of DNA....

  20. Liquid effluent Sampling and Analysis Plan (SAP) implementation summary report

    International Nuclear Information System (INIS)

    Lueck, K.J.

    1995-01-01

    This report summarizes liquid effluent analytical data collected during the Sampling and Analysis Plan (SAP) Implementation Program, evaluates whether or not the sampling performed meets the requirements of the individual SAPs, compares the results to the WAC 173-200 Ground Water Quality Standards. Presented in the report are results from liquid effluent samples collected (1992-1994) from 18 of the 22 streams identified in the Consent Order (No. DE 91NM-177) requiring SAPs

  1. Subrandom methods for multidimensional nonuniform sampling.

    Science.gov (United States)

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. The effects of preparation, shipment and ageing on the Pu elemental assay results of milligram-sized samples

    International Nuclear Information System (INIS)

    Berger, J.; Doubek, N.; Jammet, G.; Aigner, H.; Bagliano, G.; Donohue, D.; Kuhn, E.

    1994-02-01

    Specialized procedures have been implemented for the sampling of Pu-containing materials such as Pu nitrate, oxide or mixed oxide in States which have not yet approved type B(U) shipment containers for the air-shipment of gram-sized quantities of Pu. In such cases, it it necessary to prepare samples for shipment which contain only milligram quantities of Pu dried from solution in penicillin vials. Potential problems due to flaking-off during shipment could affect the recovery of Pu at the analytical laboratory. Therefore, a series of tests was performed with synthetic Pu nitrated, and mixed U, Pu nitrated samples to test the effectiveness of the evaporation and recovery procedures. Results of these tests as well as experience with actual inspection samples are presented, showing conclusively that the existing procedures are satisfactory. (author). 11 refs, 6 figs, 8 tabs

  3. Comparative Evaluation of Three Homogenization Methods for Isolating Middle East Respiratory Syndrome Coronavirus Nucleic Acids From Sputum Samples for Real-Time Reverse Transcription PCR.

    Science.gov (United States)

    Sung, Heungsup; Yong, Dongeun; Ki, Chang Seok; Kim, Jae Seok; Seong, Moon Woo; Lee, Hyukmin; Kim, Mi Na

    2016-09-01

    Real-time reverse transcription PCR (rRT-PCR) of sputum samples is commonly used to diagnose Middle East respiratory syndrome coronavirus (MERS-CoV) infection. Owing to the difficulty of extracting RNA from sputum containing mucus, sputum homogenization is desirable prior to nucleic acid isolation. We determined optimal homogenization methods for isolating viral nucleic acids from sputum. We evaluated the following three sputum-homogenization methods: proteinase K and DNase I (PK-DNase) treatment, phosphate-buffered saline (PBS) treatment, and N-acetyl-L-cysteine and sodium citrate (NALC) treatment. Sputum samples were spiked with inactivated MERS-CoV culture isolates. RNA was extracted from pretreated, spiked samples using the easyMAG system (bioMérieux, France). Extracted RNAs were then subjected to rRT-PCR for MERS-CoV diagnosis (DiaPlex Q MERS-coronavirus, SolGent, Korea). While analyzing 15 spiked sputum samples prepared in technical duplicate, false-negative results were obtained with five (16.7%) and four samples (13.3%), respectively, by using the PBS and NALC methods. The range of threshold cycle (Ct) values observed when detecting upE in sputum samples was 31.1-35.4 with the PK-DNase method, 34.7-39.0 with the PBS method, and 33.9-38.6 with the NALC method. Compared with the control, which were prepared by adding a one-tenth volume of 1:1,000 diluted viral culture to PBS solution, the ranges of Ct values obtained by the PBS and NALC methods differed significantly from the mean control Ct of 33.2 (both Phomogenizing sputum samples prior to RNA extraction.

  4. Prospective study comparing laparoscopic and open adenomectomy: Surgical and functional results.

    Science.gov (United States)

    Garcia-Segui, A; Angulo, J C

    Open adenomectomy (OA) is the surgery of choice for large volume benign prostatic hyperplasia, and laparoscopic adenomectomy (LA) represents a minimally invasive alternative. We present a long-term, prospective study comparing both techniques. The study consecutively included 199 patients with benign prostatic hyperplasia and prostate volumes>80g who were followed for more than 12 months. The patients underwent OA (n=97) or LA (n=102). We recorded and compared demographic and perioperative data, functional results and complications using a descriptive statistical analysis. The mean age was 69.2±7.7 years (range 42-87), and the mean prostate volume (measured by TRUS) was 112.1±32.7mL (range 78-260). There were no baseline differences among the groups in terms of age, ASA scale, prostate volume, PSA levels, Qmax, IPSS, QoL or treatments prior to the surgery. The surgical time (P<.0001) and catheter time (P<.0002) were longer in the LA group. Operative bleeding (P<.0001), transfusion rate (P=.0015) and mean stay (P<.0001) were significantly lower in the LA group. The LA group had a lower rate of complications (P=.04), but there were no significant differences between the groups in terms of major complications (Clavien score≥3) (P=.13) or in the rate of late complications (at one year) (P=.66). There were also no differences between the groups in the functional postoperative results: IPSS (P=.17), QoL (P=.3) and Qmax (P=.17). LA is a reasonable, safe and effective alternative that results in less bleeding, fewer transfusions, shorter hospital stays and lower morbidity than OA. LA has similar functional results to OA, at the expense of longer surgical times and longer catheter times. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. On-capillary sample cleanup method for the electrophoretic determination of carbohydrates in juice samples.

    Science.gov (United States)

    Morales-Cid, Gabriel; Simonet, Bartolomé M; Cárdenas, Soledad; Valcárcel, Miguel

    2007-05-01

    On many occasions, sample treatment is a critical step in electrophoretic analysis. As an alternative to batch procedures, in this work, a new strategy is presented with a view to develop an on-capillary sample cleanup method. This strategy is based on the partial filling of the capillary with carboxylated single-walled carbon nanotube (c-SWNT). The nanoparticles retain interferences from the matrix allowing the determination and quantification of carbohydrates (viz glucose, maltose and fructose). The precision of the method for the analysis of real samples ranged from 5.3 to 6.4%. The proposed method was compared with a method based on a batch filtration of the juice sample through diatomaceous earth and further electrophoretic determination. This method was also validated in this work. The RSD for this other method ranged from 5.1 to 6%. The results obtained by both methods were statistically comparable demonstrating the accuracy of the proposed methods and their effectiveness. Electrophoretic separation of carbohydrates was achieved using 200 mM borate solution as a buffer at pH 9.5 and applying 15 kV. During separation, the capillary temperature was kept constant at 40 degrees C. For the on-capillary cleanup method, a solution containing 50 mg/L of c-SWNTs prepared in 300 mM borate solution at pH 9.5 was introduced for 60 s into the capillary just before sample introduction. For the electrophoretic analysis of samples cleaned in batch with diatomaceous earth, it is also recommended to introduce into the capillary, just before the sample, a 300 mM borate solution as it enhances the sensitivity and electrophoretic resolution.

  6. Using Patient Health Questionnaire-9 item parameters of a common metric resulted in similar depression scores compared to independent item response theory model reestimation.

    Science.gov (United States)

    Liegl, Gregor; Wahl, Inka; Berghöfer, Anne; Nolte, Sandra; Pieh, Christoph; Rose, Matthias; Fischer, Felix

    2016-03-01

    To investigate the validity of a common depression metric in independent samples. We applied a common metrics approach based on item-response theory for measuring depression to four German-speaking samples that completed the Patient Health Questionnaire (PHQ-9). We compared the PHQ item parameters reported for this common metric to reestimated item parameters that derived from fitting a generalized partial credit model solely to the PHQ-9 items. We calibrated the new model on the same scale as the common metric using two approaches (estimation with shifted prior and Stocking-Lord linking). By fitting a mixed-effects model and using Bland-Altman plots, we investigated the agreement between latent depression scores resulting from the different estimation models. We found different item parameters across samples and estimation methods. Although differences in latent depression scores between different estimation methods were statistically significant, these were clinically irrelevant. Our findings provide evidence that it is possible to estimate latent depression scores by using the item parameters from a common metric instead of reestimating and linking a model. The use of common metric parameters is simple, for example, using a Web application (http://www.common-metrics.org) and offers a long-term perspective to improve the comparability of patient-reported outcome measures. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. MetaComp: comprehensive analysis software for comparative meta-omics including comparative metagenomics.

    Science.gov (United States)

    Zhai, Peng; Yang, Longshu; Guo, Xiao; Wang, Zhe; Guo, Jiangtao; Wang, Xiaoqi; Zhu, Huaiqiu

    2017-10-02

    During the past decade, the development of high throughput nucleic sequencing and mass spectrometry analysis techniques have enabled the characterization of microbial communities through metagenomics, metatranscriptomics, metaproteomics and metabolomics data. To reveal the diversity of microbial communities and interactions between living conditions and microbes, it is necessary to introduce comparative analysis based upon integration of all four types of data mentioned above. Comparative meta-omics, especially comparative metageomics, has been established as a routine process to highlight the significant differences in taxon composition and functional gene abundance among microbiota samples. Meanwhile, biologists are increasingly concerning about the correlations between meta-omics features and environmental factors, which may further decipher the adaptation strategy of a microbial community. We developed a graphical comprehensive analysis software named MetaComp comprising a series of statistical analysis approaches with visualized results for metagenomics and other meta-omics data comparison. This software is capable to read files generated by a variety of upstream programs. After data loading, analyses such as multivariate statistics, hypothesis testing of two-sample, multi-sample as well as two-group sample and a novel function-regression analysis of environmental factors are offered. Here, regression analysis regards meta-omic features as independent variable and environmental factors as dependent variables. Moreover, MetaComp is capable to automatically choose an appropriate two-group sample test based upon the traits of input abundance profiles. We further evaluate the performance of its choice, and exhibit applications for metagenomics, metaproteomics and metabolomics samples. MetaComp, an integrative software capable for applying to all meta-omics data, originally distills the influence of living environment on microbial community by regression analysis

  8. Examining the "Veggie" personality: Results from a representative German sample.

    Science.gov (United States)

    Pfeiler, Tamara M; Egloff, Boris

    2018-01-01

    An increasing proportion of people choose to follow a vegetarian diet. To date, however, little is known about if and how individual differences in personality relate to following a vegetarian diet. In the two studies presented here, we aimed to (1) estimate the prevalence of self-defined vegetarians in two waves of a German representative sample (N = 4496 and 5125, respectively), (2) analyze the effect of socio-demographic variables on dietary behavior, and (3) examine individual differences between vegetarians and meat eaters in personality traits, political attitudes, and health-related variables. In Study 1, a strict definition of vegetarians was used, while in Study 2 the definition was laxer, to include also individuals who only predominantly followed a vegetarian diet. The prevalence of self-defined vegetarians was 2.74% in Study 1, and 5.97% in Study 2. Participants who were female, younger, and more educated were more likely to report following a vegetarian diet in both studies, and vegetarians had higher income as compared to meat eaters in Study 2. We also found differences between vegetarians and meat eaters with regard to personality traits, political attitudes, and health-related variables. Stepwise logistic regression analyses showed a unique effect beyond socio-demographic variables for openness (Studies 1 and 2), conscientiousness (Study 1), trust (Study 2), conservatism (Studies 1 and 2), and level of interest in politics (Study 1) on diet: Individuals with higher scores in openness and political interest had a higher probability of being vegetarian, whereas people with higher scores in conscientiousness and conservatism had a smaller likelihood of being vegetarian. We conclude that there are individual differences between vegetarians and meat eaters in socio-demographics, personality traits, and political attitudes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Variation of calcium, copper and iron levels in serum, bile and stone samples of patients having different types of gallstone: A comparative study.

    Science.gov (United States)

    Khan, Mustafa; Kazi, Tasneem Gul; Afridi, Hassan Imran; Sirajuddin; Bilal, Muhammad; Akhtar, Asma; Khan, Sabir; Kadar, Salma

    2017-08-01

    Epidemiological data among the human population has shown a significantly increased incidence of gallstone (GS) disease worldwide. It was studied that some essential (calcium) and transition elements (iron and copper) in bile play an important role in the development of GS. The estimation of calcium, copper and iron were carried out in the serum, gall bladder bile and different types of GS (cholesterol, mixed and pigmented) of 172 patients, age ranged 20-55years. For comparative purpose age matched referents not suffering from GS diseases were also selected. Biliary concentrations of calcium (Ca), iron (Fe) and copper (Cu) were correlated with their concentrations in serum and different types of GS samples. The ratio of Ca, Fe and Cu in bile with serum was also calculated. Understudy metals were determined by flame atomic absorption spectroscopy after acid decomposition of matrices of selected samples. The Ca concentrations in serum samples were significantly higher in patients with pigmented GS as compared to controls (p0.001). The contents of Cu and Fe in serum and bile of all patients (except female cholesterol GS patient have low serum iron concentration) were found to be higher than control, but difference was significant in those patients who have pigmented GS. The concentration of Ca, Fe and Cu in different types GS were found in the order, Pigmented>mixed>cholesterol. The bile/serum ratio for Ca, Cu and Fe was found to be significantly higher in pigmented GS patients. Gall bladder bile was slightly alkaline in patients as compared to referents. The density of bile was found to be higher in patients as compared to the referents. Various functional groups present in different types of GS samples were confirmed by Fourier transform infra-red spectroscopy. The higher density and pH of bile, elevated concentrations of transition elements in all types of biological samples (serum, bile and GS), could be an important factor for the formation of different types of

  10. Results of the analyses of the intercomparison samples of natural dioxide SR-1

    International Nuclear Information System (INIS)

    Aigner, H.; Kuhn, E.; Deron, S.

    1980-08-01

    Samples of a homogeneous powder of natural uranium dioxide, SR-1, were distributed to 37 laboratories in November 1977 for intercomparison of the precisions and accuracies of wet chemical assays. 17 laboratories reported 18 sets of results (one laboratory applied two techniques). The analytical methods which were applied were: titration (11), coulometry (2), precipitation-gravimetry (1), flourimetry (2), X-Ray flourescence (1) and neutron activation (1). Analysis of variance yield for each combination of laboratory and technique the estimates of the measurement errors, the dissolution or treatment errors and the fluctuation of the measurements between sample bottles. Time effects have also been tested. The measurement errors vary between 0.01% and 6.4%. Eleven laboratories agree within 0.25% with the reference value. No mean obtained by wet chemical methods is biased by more than 0.4%. The biases of the other methods (flourimetry, X-Ray fluorescence and neutron activation) vary between 0.5% and 4.3%. The biases of 9 laboratories or techniques are greater than expected from their random errors. The mean bias of the fourteen wet chemical methods is equal to 0.08% U with a standard deviation of +-0.18% U

  11. Comparisons of PGA and INAA in the analyses of meteorite samples

    International Nuclear Information System (INIS)

    Wee Boon Siong; Ebihara, M.; Abdul Khalik Wood

    2010-01-01

    Prompt gamma-ray analysis (PGA) and instrumental neutron activation analysis (INAA) are suitable methods for multi-elemental determinations in various samples. These two methods are complementary because PGA is capable of analyzing most major and minor elements in rock samples whereas INAA is more superior in determining minor and trace elements. Both PGA and INAA are essential for the study of rare samples such as meteorites because of non-destructivity and relatively being free from contaminations. Samples for PGA can be reused for INAA, which help to reduce the sample usage. This project aims to utilize PGA and INAA techniques for comparative study and apply them to meteorites. In this study, 11 meteorite samples received from the Meteorite Working Group of NASA were analyzed. The Allende meteorite powder was included as quality control material. Results from PGA and INAA for Allende showed good agreement with literature values, signifying the reliabilities of these two methods. Elements Al, Ca, Mg, Mn, Na and Ti were determined by both methods and their results are compared. Comparison of PGA and INAA data using linear regression analysis showed correlations coefficients r 2 > 0.90 for Al, Ca, Mn and Ti, 0.85 for Mg, and 0.38 for Na. The PGA results for Na using 472 keV were less accurate due to the interference from the broad B peak. Therefore, Na results from INAA method are preferred. For other elements (Al, Ca, Mg, Mn and Ti), PGA and INAA results can be used as cross-reference for consistency. The PGA and INAA techniques have been applied to meteorite samples and results are comparable to literature values compiled from previously analyzed meteorites. In summary, both PGA and INAA methods give reasonably good agreement and are indispensable in the study of meteorites. (author)

  12. THE CIRCUMGALACTIC MEDIUM OF SUBMILLIMETER GALAXIES. I. FIRST RESULTS FROM A RADIO-IDENTIFIED SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Hai; Mutel, R.; Isbell, J.; Lang, C.; McGinnis, D. [Department of Physics and Astronomy, University of Iowa, Iowa City, IA 52242 (United States); Hennawi, J. F. [Max-Planck-Institut fur Astronomie, Heidelberg (Germany); Prochaska, J. X. [Department of Astronomy and Astrophysics, UCO/Lick Observatory, University of California, 1156 High Street, Santa Cruz, CA 95064 (United States); Casey, C. [Department of Astronomy, the University of Texas at Austin, 2515 Speedway Blvd, Stop C1400, Austin, TX 78712 (United States); Cooray, A. [Department of Physics and Astronomy, University of California, Irvine, CA 92697 (United States); Kereš, D. [Department of Physics, Center for Astrophysics and Space Sciences, University of California at San Diego, 9500 Gilman Drive, La Jolla, CA 92093 (United States); Zhang, Z.-Y.; Michałowski, M. J. [Institute for Astronomy, University of Edinburgh, Royal Observatory, Blackford Hill, Edinburgh EH9 3HJ (United Kingdom); Clements, D. [Astrophysics Group, Imperial College London, Blackett Laboratory, Prince Consort Road, London SW7 2AZ (United Kingdom); Mooley, K. [Oxford Centre For Astrophysical Surveys, Denys Wilkinson Building, Keble Road, Oxford OX1 3RH (United States); Perley, D. [Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, DK-2100 København Ø (Denmark); Stockton, A. [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States); Thompson, D. [Large Binocular Telescope Observatory, University of Arizona, 933 N. Cherry Ave, Tucson, AZ 85721 (United States)

    2016-11-20

    We present the first results from an ongoing survey to characterize the circumgalactic medium (CGM) of massive high-redshift galaxies detected as submillimeter galaxies (SMGs). We constructed a parent sample of 163 SMG–QSO pairs with separations less than ∼36″ by cross-matching far-infrared-selected galaxies from Herschel with spectroscopically confirmed QSOs. The Herschel sources were selected to match the properties of the SMGs. We determined the sub-arcsecond positions of six Herschel sources with the Very Large Array and obtained secure redshift identification for three of those with near-infrared spectroscopy. The QSO sightlines probe transverse proper distances of 112, 157, and 198 kpc at foreground redshifts of 2.043, 2.515, and 2.184, respectively, which are comparable to the virial radius of the ∼10{sup 13} M {sub ⊙} halos expected to host SMGs. High-quality absorption-line spectroscopy of the QSOs reveals systematically strong H i Ly α absorption around all three SMGs, with rest-frame equivalent widths of ∼2–3 Å. However, none of the three absorbers exhibit compelling evidence for optically thick H i gas or metal absorption, in contrast to the dominance of strong neutral absorbers in the CGM of luminous z ∼ 2 QSOs. The low covering factor of optically thick H i gas around SMGs tentatively indicates that SMGs may not have as prominent cool gas reservoirs in their halos as the coeval QSOs and that they may inhabit less massive halos than previously thought.

  13. Analytical results and sample locality map for rock, stream-sediment, and soil samples, Northern and Eastern Coloado Desert BLM Resource Area, Imperial, Riverside, and San Bernardino Counties, California

    Science.gov (United States)

    King, Harley D.; Chaffee, Maurice A.

    2000-01-01

    Desert BLM Resource Area and vicinity. Included in the 1,245 stream-sediment samples collected by the USGS are 284 samples collected as part of the current study, 817 samples collected as part of investigations of the12 BLM WSAs and re-analyzed for the present study, 45 samples from the Needles 1? X 2? quadrangle, and 99 samples from the El Centro 1? X 2? quadrangle. The NURE stream-sediment and soil samples were re-analyzed as part of the USGS study in the Needles quadrangle. Analytical data for samples from the Chocolate Mountain Aerial Gunnery Range, which is located within the area of the NECD, were previously reported (King and Chaffee, 1999a). For completeness, these results are also included in this report. Analytical data for samples from the area of Joshua Tree National Park that is within the NECD have also been reported (King and Chaffee, 1999b). These results are not included in this report. The analytical data presented here can be used for baseline geochemical, mineral resource, and environmental geochemical studies.

  14. Defining And Characterizing Sample Representativeness For DWPF Melter Feed Samples

    Energy Technology Data Exchange (ETDEWEB)

    Shine, E. P.; Poirier, M. R.

    2013-10-29

    Representative sampling is important throughout the Defense Waste Processing Facility (DWPF) process, and the demonstrated success of the DWPF process to achieve glass product quality over the past two decades is a direct result of the quality of information obtained from the process. The objective of this report was to present sampling methods that the Savannah River Site (SRS) used to qualify waste being dispositioned at the DWPF. The goal was to emphasize the methodology, not a list of outcomes from those studies. This methodology includes proven methods for taking representative samples, the use of controlled analytical methods, and data interpretation and reporting that considers the uncertainty of all error sources. Numerous sampling studies were conducted during the development of the DWPF process and still continue to be performed in order to evaluate options for process improvement. Study designs were based on use of statistical tools applicable to the determination of uncertainties associated with the data needs. Successful designs are apt to be repeated, so this report chose only to include prototypic case studies that typify the characteristics of frequently used designs. Case studies have been presented for studying in-tank homogeneity, evaluating the suitability of sampler systems, determining factors that affect mixing and sampling, comparing the final waste glass product chemical composition and durability to that of the glass pour stream sample and other samples from process vessels, and assessing the uniformity of the chemical composition in the waste glass product. Many of these studies efficiently addressed more than one of these areas of concern associated with demonstrating sample representativeness and provide examples of statistical tools in use for DWPF. The time when many of these designs were implemented was in an age when the sampling ideas of Pierre Gy were not as widespread as they are today. Nonetheless, the engineers and

  15. Defining And Characterizing Sample Representativeness For DWPF Melter Feed Samples

    International Nuclear Information System (INIS)

    Shine, E. P.; Poirier, M. R.

    2013-01-01

    Representative sampling is important throughout the Defense Waste Processing Facility (DWPF) process, and the demonstrated success of the DWPF process to achieve glass product quality over the past two decades is a direct result of the quality of information obtained from the process. The objective of this report was to present sampling methods that the Savannah River Site (SRS) used to qualify waste being dispositioned at the DWPF. The goal was to emphasize the methodology, not a list of outcomes from those studies. This methodology includes proven methods for taking representative samples, the use of controlled analytical methods, and data interpretation and reporting that considers the uncertainty of all error sources. Numerous sampling studies were conducted during the development of the DWPF process and still continue to be performed in order to evaluate options for process improvement. Study designs were based on use of statistical tools applicable to the determination of uncertainties associated with the data needs. Successful designs are apt to be repeated, so this report chose only to include prototypic case studies that typify the characteristics of frequently used designs. Case studies have been presented for studying in-tank homogeneity, evaluating the suitability of sampler systems, determining factors that affect mixing and sampling, comparing the final waste glass product chemical composition and durability to that of the glass pour stream sample and other samples from process vessels, and assessing the uniformity of the chemical composition in the waste glass product. Many of these studies efficiently addressed more than one of these areas of concern associated with demonstrating sample representativeness and provide examples of statistical tools in use for DWPF. The time when many of these designs were implemented was in an age when the sampling ideas of Pierre Gy were not as widespread as they are today. Nonetheless, the engineers and

  16. The comparability of men who have sex with men recruited from venue-time-space sampling and facebook: a cohort study.

    Science.gov (United States)

    Hernandez-Romieu, Alfonso C; Sullivan, Patrick S; Sanchez, Travis H; Kelley, Colleen F; Peterson, John L; Del Rio, Carlos; Salazar, Laura F; Frew, Paula M; Rosenberg, Eli S

    2014-07-17

    Recruiting valid samples of men who have sex with men (MSM) is a key component of the US human immunodeficiency virus (HIV) surveillance and of research studies seeking to improve HIV prevention for MSM. Social media, such as Facebook, may present an opportunity to reach broad samples of MSM, but the extent to which those samples are comparable with men recruited from venue-based, time-space sampling (VBTS) is unknown. The objective of this study was to assess the comparability of MSM recruited via VBTS and Facebook. HIV-negative and HIV-positive black and white MSM were recruited from June 2010 to December 2012 using VBTS and Facebook in Atlanta, GA. We compared the self-reported venue attendance, demographic characteristics, sexual and risk behaviors, history of HIV-testing, and HIV and sexually transmitted infection (STI) prevalence between Facebook- and VTBS-recruited MSM overall and by race. Multivariate logistic and negative binomial models estimated age/race adjusted ratios. The Kaplan-Meier method was used to assess 24-month retention. We recruited 803 MSM, of whom 110 (34/110, 30.9% black MSM, 76/110, 69.1% white MSM) were recruited via Facebook and 693 (420/693, 60.6% black MSM, 273/693, 39.4% white MSM) were recruited through VTBS. Facebook recruits had high rates of venue attendance in the previous month (26/34, 77% among black and 71/76, 93% among white MSM; between-race P=.01). MSM recruited on Facebook were generally older, with significant age differences among black MSM (P=.02), but not white MSM (P=.14). In adjusted multivariate models, VBTS-recruited MSM had fewer total partners (risk ratio [RR]=0.78, 95% CI 0.64-0.95; P=.01) and unprotected anal intercourse (UAI) partners (RR=0.54, 95% CI 0.40-0.72; PFacebook, to 77% for black and 78% for white MSM recruited at venues. There was no statistically significant differences in retention between the four groups (log-rank P=.64). VBTS and Facebook recruitment methods yielded similar samples of MSM in

  17. The use of mini-samples in palaeomagnetism

    Science.gov (United States)

    Böhnel, Harald; Michalk, Daniel; Nowaczyk, Norbert; Naranjo, Gildardo Gonzalez

    2009-10-01

    Rock cores of ~25 mm diameter are widely used in palaeomagnetism. Occasionally smaller diameters have been used as well which represents distinct advantages in terms of throughput, weight of equipment and core collections. How their orientation precision compares to 25 mm cores, however, has not been evaluated in detail before. Here we compare the site mean directions and their statistical parameters for 12 lava flows sampled with 25 mm cores (standard samples, typically 8 cores per site) and with 12 mm drill cores (mini-samples, typically 14 cores per site). The site-mean directions for both sample sizes appear to be indistinguishable in most cases. For the mini-samples, site dispersion parameters k on average are slightly lower than for the standard samples reflecting their larger orienting and measurement errors. Applying the Wilcoxon signed-rank test the probability that k or α95 have the same distribution for both sizes is acceptable only at the 17.4 or 66.3 per cent level, respectively. The larger mini-core numbers per site appears to outweigh the lower k values yielding also slightly smaller confidence limits α95. Further, both k and α95 are less variable for mini-samples than for standard size samples. This is interpreted also to result from the larger number of mini-samples per site, which better averages out the detrimental effect of undetected abnormal remanence directions. Sampling of volcanic rocks with mini-samples therefore does not present a disadvantage in terms of the overall obtainable uncertainty of site mean directions. Apart from this, mini-samples do present clear advantages during the field work, as about twice the number of drill cores can be recovered compared to 25 mm cores, and the sampled rock unit is then more widely covered, which reduces the contribution of natural random errors produced, for example, by fractures, cooling joints, and palaeofield inhomogeneities. Mini-samples may be processed faster in the laboratory, which is of

  18. Planck early results. VIII. The all-sky early Sunyaev-Zeldovich cluster sample

    DEFF Research Database (Denmark)

    Poutanen, T.; Natoli, P.; Polenta, G.

    2011-01-01

    We present the first all-sky sample of galaxy clusters detected blindly by the Planck satellite through the Sunyaev-Zeldovich (SZ) effect from its six highest frequencies. This early SZ (ESZ) sample is comprised of 189 candidates, which have a high signal-to-noise ratio ranging from 6 to 29. Its ...

  19. Adolescent Psychopathy and the Big Five: Results from Two Samples

    Science.gov (United States)

    Lynam, Donald R.; Caspi, Avshalom; Moffitt, Terrie E.; Raine, Adrian; Loeber, Rolf; Stouthamer-Loeber, Magda

    2005-01-01

    The present study examines the relation between psychopathy and the Big Five dimensions of personality in two samples of adolescents. Specifically, the study tests the hypothesis that the aspect of psychopathy representing selfishness, callousness, and interpersonal manipulation (Factor 1) is most strongly associated with low Agreeableness,…

  20. Comparative study of uranium concentration in water samples of SW and NE Punjab, India

    International Nuclear Information System (INIS)

    Saini, Komal; Bajwa, B.S.

    2014-01-01

    Since the commencement of the earth, radiations and natural radioactivity has always been a part of environment. Uranium is heaviest naturally occurring element which is widespread in nature, mainly occurs in granites mineral deposits. The natural weathering of rocks such as granite dissolves the natural uranium, which goes into groundwater by leaching and precipitation called illumination process. People are always exposed to certain amount of uranium from air, water, soil and food as it is usually present in these components. About 85% of ingested uranium enter into human body through drinking water which makes it very important to estimate uranium concentration in potable water. Uranium and some other heavy metals may increase the risk of kidney damage, cancer diseases where experimental evidence suggests that respiratory and reproductive system are also affected by uranium exposure. In the present study comparative study of uranium concentration in potable water samples of SW and NE Punjab has been analysed

  1. Comparative evaluation of serum, FTA filter-dried blood and oral fluid as sample material for PRRSV diagnostics by RT-qPCR in a small-scale experimental study.

    Science.gov (United States)

    Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana

    2014-01-01

    Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.

  2. Tank Vapor Characterization Project: Headspace vapor characterization of Hanford Tank 241-TY-102: Results from samples collected on 04/12/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-TY-102 (Tank TY-102) at the Hanford Site in Washington State. The results described in this report were obtained to'characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes, and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in Table S.1. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples are also listed in Table S.1. Detailed descriptions of the analytical results appear in the appendices

  3. Tank Vapor Characterization Project: Headspace vapor characterization of Hanford Tank 241-B-105: Results from samples collected on 07/30/96

    International Nuclear Information System (INIS)

    Pool, K.H.; Evans, J.C.; Thomas, B.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-B-105 (Tank B-105) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in Table S.1. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples are also listed in Table S.1. Detailed descriptions of the analytical results appear in the appendices

  4. Comparison of air samples, nasal swabs, ear-skin swabs and environmental dust samples for detection of Methicillin Resistant Staphylococcus aureus (MRSA) in pig herds

    DEFF Research Database (Denmark)

    Agersø, Yvonne; Vigre, Håkan; Cavaco, Lina

    2014-01-01

    To identify a cost-effective and practical method for detection of methicillin-resistant Staphylococcus aureus (MRSA) in pig herds, the relative sensitivity of four sample types: nasal swabs, ear-skin (skin behind the ears) swabs, environmental dust swabs and air was compared. Moreover, dependency......-herd prevalence ⩾25%]. The results indicate that taking swabs of skin behind the ears (ten pools of five) was even more sensitive than taking nasal swabs (ten pools of five) at the herd level and detected significantly more positive samples. spa types t011, t034 and t4208 were observed. In conclusion, MRSA...... detection by air sampling is easy to perform, reduces costs and analytical time compared to existing methods, and is recommended for initial testing of herds. Ear-skin swab sampling may be more sensitive for MRSA detection than air sampling or nasal swab sampling....

  5. [A comparison of convenience sampling and purposive sampling].

    Science.gov (United States)

    Suen, Lee-Jen Wu; Huang, Hui-Man; Lee, Hao-Hsien

    2014-06-01

    Convenience sampling and purposive sampling are two different sampling methods. This article first explains sampling terms such as target population, accessible population, simple random sampling, intended sample, actual sample, and statistical power analysis. These terms are then used to explain the difference between "convenience sampling" and purposive sampling." Convenience sampling is a non-probabilistic sampling technique applicable to qualitative or quantitative studies, although it is most frequently used in quantitative studies. In convenience samples, subjects more readily accessible to the researcher are more likely to be included. Thus, in quantitative studies, opportunity to participate is not equal for all qualified individuals in the target population and study results are not necessarily generalizable to this population. As in all quantitative studies, increasing the sample size increases the statistical power of the convenience sample. In contrast, purposive sampling is typically used in qualitative studies. Researchers who use this technique carefully select subjects based on study purpose with the expectation that each participant will provide unique and rich information of value to the study. As a result, members of the accessible population are not interchangeable and sample size is determined by data saturation not by statistical power analysis.

  6. Comparative evaluation of prokaryotic 16S rDNA clone libraries and SSCP in groundwater samples.

    Science.gov (United States)

    Larentis, Michael; Alfreider, Albin

    2011-06-01

    A comparison of ribosomal RNA sequence analysis methods based on clone libraries and single-strand conformational polymorphism technique (SSCP) was performed with groundwater samples obtained between 523-555 meters below surface. The coverage of analyzed clones by phylotype-richness estimates was between 88-100%, confirming that the clone libraries were adequately examined. Analysis of individual bands retrieved from SSCP gels identified 1-6 different taxonomic units per band, suggesting that a single SSCP band does often represent more than one single prokaryotic species. The prokaryotic diversity obtained by both methods showed an overall difference of 42-80%. In comparison to SSCP, clone libraries underestimated the phylogenetic diversity and only 36-66% of the phylotypes observed with SSCP were also detected with the clone libraries. An exception was a sample where the SSCP analysis of Archaea identified only half of the phylotypes retrieved by the clone library. Overall, this study suggests that the clone library and the SSCP approach do not provide an identical picture of the prokaryotic diversity in groundwater samples. The results clearly show that the SSCP method, although this approach is prone to generate methodological artifacts, was able to detect significantly more phylotypes than microbial community analysis based on clone libraries. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. After Action Report - CUP-2 Comparative Sample Analysis Meeting - Kazakhstan September 2016

    Energy Technology Data Exchange (ETDEWEB)

    Kips, Ruth [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Lindvall, Rachel [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Eppich, Gary [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Oujo, Kaitlin [National Nuclear Security Administration (NNSA), Washington, DC (United States); Geist, William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-01

    Representatives from the U.S. Department of Energy’s Office of Nuclear Smuggling Detection and Deterrence (NSDD) visited the Kazakhstan Institute of Nuclear Physics (INP) to discuss the results and conclusions of a joint sample analysis (CUP-2 uranium ore concentrate) between LLNL, INP and the Japan Atomic Energy Agency (JAEA) (Fig. 1). The U.S. delegation also met with the newly-appointed Director-General of the INP (S. Sakhiyev) who expressed his continued support for this collaboration. On the last day of the visit, the delegation toured the new medical isotope production facilities (which is expected to begin operation in a few months), as well as INP’s Nuclear Security Training Center (co-funded by DOE, the Defense Threat Reduction Initiative (DTRA) and the Kazakhstan government). Construction of the Nuclear Security Training Center is expected to be completed by the end of 2016.

  8. Vapor space characterization of waste tank 241-C-106: Results from samples collected on February 15, 1994

    International Nuclear Information System (INIS)

    McVeety, B.D.; Clauss, T.W.; Young, J.S.; Ligotke, M.W.; Goheen, S.C.; Lucke, R.B.; Pool, K.H.; McCulloch, M.; Fruchter, J.S.

    1995-06-01

    This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 241-C-106. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text

  9. Sampling designs and methods for estimating fish-impingement losses at cooling-water intakes

    International Nuclear Information System (INIS)

    Murarka, I.P.; Bodeau, D.J.

    1977-01-01

    Several systems for estimating fish impingement at power plant cooling-water intakes are compared to determine the most statistically efficient sampling designs and methods. Compared to a simple random sampling scheme the stratified systematic random sampling scheme, the systematic random sampling scheme, and the stratified random sampling scheme yield higher efficiencies and better estimators for the parameters in two models of fish impingement as a time-series process. Mathematical results and illustrative examples of the applications of the sampling schemes to simulated and real data are given. Some sampling designs applicable to fish-impingement studies are presented in appendixes

  10. Factorial Validity of the ADHD Adult Symptom Rating Scale in a French Community Sample: Results From the ChiP-ARD Study.

    Science.gov (United States)

    Morin, Alexandre J S; Tran, Antoine; Caci, Hervé

    2016-06-01

    Recent publications reported that a bifactor model better represented the underlying structure of ADHD than classical models, at least in youth. The Adult ADHD Symptoms Rating Scale (ASRS) has been translated into many languages, but a single study compared its structure in adults across Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV) and International Classification of Diseases (ICD-10) classifications. We investigated the factor structure, reliability, and measurement invariance of the ASRS among a community sample of 1,171 adults. Results support a bifactor model, including one general ADHD factor and three specific Inattention, Hyperactivity, and Impulsivity factors corresponding to ICD-10, albeit the Impulsivity specific factor was weakly defined. Results also support the complete measurement invariance of this model across gender and age groups, and that men have higher scores than women on the ADHD G-factor but lower scores on all three S-factors. Results suggest that a total ASRS-ADHD score is meaningful, reliable, and valid in adults. (J. of Att. Dis. 2016; 20(6) 530-541). © The Author(s) 2013.

  11. Approximation of the exponential integral (well function) using sampling methods

    Science.gov (United States)

    Baalousha, Husam Musa

    2015-04-01

    Exponential integral (also known as well function) is often used in hydrogeology to solve Theis and Hantush equations. Many methods have been developed to approximate the exponential integral. Most of these methods are based on numerical approximations and are valid for a certain range of the argument value. This paper presents a new approach to approximate the exponential integral. The new approach is based on sampling methods. Three different sampling methods; Latin Hypercube Sampling (LHS), Orthogonal Array (OA), and Orthogonal Array-based Latin Hypercube (OA-LH) have been used to approximate the function. Different argument values, covering a wide range, have been used. The results of sampling methods were compared with results obtained by Mathematica software, which was used as a benchmark. All three sampling methods converge to the result obtained by Mathematica, at different rates. It was found that the orthogonal array (OA) method has the fastest convergence rate compared with LHS and OA-LH. The root mean square error RMSE of OA was in the order of 1E-08. This method can be used with any argument value, and can be used to solve other integrals in hydrogeology such as the leaky aquifer integral.

  12. Environmental radiation levels in soil and sediment samples collected from floating water from a land runway resulting from heavy rains in the Jeddah region, KSA

    International Nuclear Information System (INIS)

    Mohery, M.; Baz, Shadiah; Kelany, Adel M.; Abdallah, A.M.

    2014-01-01

    The natural radiation levels in soil and sediment samples collected from floating water from a land runway resulting from heavy rains in the Jeddah region as well as the activity in the population of its surrounding environments were studied. In the regions surrounding Jeddah, the movements of floating water may increase the concentration of radioactivity due to the movement of soil due to heavy rains. In addition, the technological development of industry, agriculture and other sources around the Jeddah region has increased environmental pollution, resulting in noticeable concentrations of radioactivity. The measured activity concentrations of 214 Pb, 214 Bi, 228 Ac, 208 Tl, 40 K, 226 Ra and 228 Ra in the studied area suggest that they are within the world average for soils and sediments, except those for water sample no. 4; the concentration in this sample was five times higher than the world average concentration (this water is not consumable). Herein, the radioactivity concentrations that were obtained from the analysis of soil and sediment samples that were collected from the investigated area are discussed. Additionally, the absorbed dose rate (D), radium equivalent activity (Ra eq ), external hazard index (H ex ), annual gonadal dose equivalent (AGDE) and annual effective dose equivalent (AEDE) were evaluated. For the soil and sediment samples, the average radioactivity concentrations were determined for each site and are expressed in Becquerels per kilogram (Bq/kg) of dry weight, while for the measurement of both the 226 Ra and 228 Ra isotopes in the water samples, the activity concentration is expressed in picoCuries per liter (pCi/l). The obtained results were compared with other measurements from different countries. The movement of floating water around the Jeddah region increases the concentration of radioactivity due to the movement of soils with heavy rains. - Highlights: • The natural radiation levels in soil and sediment samples from floating

  13. Sample Results From The Extraction, Scrub, And Strip Test For The Blended NGS Solvent

    Energy Technology Data Exchange (ETDEWEB)

    Washington, A. L. II [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-03-03

    This report summarizes the results of the extraction, scrub, and strip testing for the September 2013 sampling of the Next Generation Solvent (NGS) Blended solvent from the Modular Caustic Side-Solvent Extraction Unit (MCU) Solvent Hold Tank. MCU is in the process of transitioning from the BOBCalixC6 solvent to the NGS Blend solvent. As part of that transition, MCU has intentionally created a blended solvent to be processed using the Salt Batch program. This sample represents the first sample received from that blended solvent. There were two ESS tests performed where NGS blended solvent performance was assessed using either the Tank 21 material utilized in the Salt Batch 7 analyses or a simulant waste material used in the V-5/V-10 contactor testing. This report tabulates the temperature corrected cesium distribution, or DCs values, step recovery percentage, and actual temperatures recorded during the experiment. This report also identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. The calculated extraction DCs values using the Tank 21H material and simulant are 59.4 and 53.8, respectively. The DCs values for two scrub and three strip processes for the Tank 21 material are 4.58, 2.91, 0.00184, 0.0252, and 0.00575, respectively. The D-values for two scrub and three strip processes for the simulant are 3.47, 2.18, 0.00468, 0.00057, and 0.00572, respectively. These values are similar to previous measurements of Salt Batch 7 feed with lab-prepared blended solvent. These numbers are considered compatible to allow simulant testing to be completed in place of actual waste due to the limited availability of feed material.

  14. Sample Results From The Extraction, Scrub, And Strip Test For The Blended NGS Solvent

    International Nuclear Information System (INIS)

    Washington, A. L. II; Peters, T. B.

    2014-01-01

    This report summarizes the results of the extraction, scrub, and strip testing for the September 2013 sampling of the Next Generation Solvent (NGS) Blended solvent from the Modular Caustic Side-Solvent Extraction Unit (MCU) Solvent Hold Tank. MCU is in the process of transitioning from the BOBCalixC6 solvent to the NGS Blend solvent. As part of that transition, MCU has intentionally created a blended solvent to be processed using the Salt Batch program. This sample represents the first sample received from that blended solvent. There were two ESS tests performed where NGS blended solvent performance was assessed using either the Tank 21 material utilized in the Salt Batch 7 analyses or a simulant waste material used in the V-5/V-10 contactor testing. This report tabulates the temperature corrected cesium distribution, or DCs values, step recovery percentage, and actual temperatures recorded during the experiment. This report also identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. The calculated extraction DCs values using the Tank 21H material and simulant are 59.4 and 53.8, respectively. The DCs values for two scrub and three strip processes for the Tank 21 material are 4.58, 2.91, 0.00184, 0.0252, and 0.00575, respectively. The D-values for two scrub and three strip processes for the simulant are 3.47, 2.18, 0.00468, 0.00057, and 0.00572, respectively. These values are similar to previous measurements of Salt Batch 7 feed with lab-prepared blended solvent. These numbers are considered compatible to allow simulant testing to be completed in place of actual waste due to the limited availability of feed material

  15. Temporal focus, temporal distance, and mind-wandering valence: Results from an experience sampling and an experimental study.

    Science.gov (United States)

    Spronken, Maitta; Holland, Rob W; Figner, Bernd; Dijksterhuis, Ap

    2016-04-01

    When mind-wandering, people may think about events that happened in the past, or events that may happen in the future. Using experience sampling, we first aimed to replicate the finding that future-oriented thoughts show a greater positivity bias than past-oriented thoughts. Furthermore, we investigated whether there is a relation between the temporal distance of past- and future-oriented thoughts and the frequency of positive thoughts, a factor that has received little attention in previous work. Second, we experimentally investigated the relation between temporal focus, temporal distance, and thought valence. Both studies showed that future-oriented thoughts were more positive compared to past-oriented thoughts. Regarding temporal distance, thoughts about the distant past and future were more positive than thoughts about the near past and future in the experiment. However, the experience sampling study did not provide clear insight into this relation. Potential theoretical and methodological explanations for these findings are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Testing a groundwater sampling tool: Are the samples representative?

    International Nuclear Information System (INIS)

    Kaback, D.S.; Bergren, C.L.; Carlson, C.A.; Carlson, C.L.

    1989-01-01

    A ground water sampling tool, the HydroPunch trademark, was tested at the Department of Energy's Savannah River Site in South Carolina to determine if representative ground water samples could be obtained without installing monitoring wells. Chemical analyses of ground water samples collected with the HydroPunch trademark from various depths within a borehole were compared with chemical analyses of ground water from nearby monitoring wells. The site selected for the test was in the vicinity of a large coal storage pile and a coal pile runoff basin that was constructed to collect the runoff from the coal storage pile. Existing monitoring wells in the area indicate the presence of a ground water contaminant plume that: (1) contains elevated concentrations of trace metals; (2) has an extremely low pH; and (3) contains elevated concentrations of major cations and anions. Ground water samples collected with the HydroPunch trademark provide in excellent estimate of ground water quality at discrete depths. Groundwater chemical data collected from various depths using the HydroPunch trademark can be averaged to simulate what a screen zone in a monitoring well would sample. The averaged depth-discrete data compared favorably with the data obtained from the nearby monitoring wells

  17. Tank Vapor Characterization Project: Headspace vapor characterization of Hanford Waste Tank U-203, Results from samples collected on August 8, 1995

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.; McVeety, B.D.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Ligotke, M.W.

    1995-11-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-U-203 (Tank U-203) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank-farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest Laboratory (PNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the results is listed. Detailed descriptions of the analytical results appear in the text

  18. Tank Vapor Characterization Project: Headspace vapor characterization of Hanford Waste Tank U-204, Results from samples collected on August 8, 1995

    International Nuclear Information System (INIS)

    Clauss, T.W.; Evans, J.C.; McVeety, B.D.; Pool, K.H.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Ligotke, M.W.

    1995-11-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-U-204 (Tank U-204) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank-farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the results is listed. Detailed descriptions of the analytical results appear in the text

  19. A Monte Carlo simulation study comparing linear regression, beta regression, variable-dispersion beta regression and fractional logit regression at recovering average difference measures in a two sample design.

    Science.gov (United States)

    Meaney, Christopher; Moineddin, Rahim

    2014-01-24

    In biomedical research, response variables are often encountered which have bounded support on the open unit interval--(0,1). Traditionally, researchers have attempted to estimate covariate effects on these types of response data using linear regression. Alternative modelling strategies may include: beta regression, variable-dispersion beta regression, and fractional logit regression models. This study employs a Monte Carlo simulation design to compare the statistical properties of the linear regression model to that of the more novel beta regression, variable-dispersion beta regression, and fractional logit regression models. In the Monte Carlo experiment we assume a simple two sample design. We assume observations are realizations of independent draws from their respective probability models. The randomly simulated draws from the various probability models are chosen to emulate average proportion/percentage/rate differences of pre-specified magnitudes. Following simulation of the experimental data we estimate average proportion/percentage/rate differences. We compare the estimators in terms of bias, variance, type-1 error and power. Estimates of Monte Carlo error associated with these quantities are provided. If response data are beta distributed with constant dispersion parameters across the two samples, then all models are unbiased and have reasonable type-1 error rates and power profiles. If the response data in the two samples have different dispersion parameters, then the simple beta regression model is biased. When the sample size is small (N0 = N1 = 25) linear regression has superior type-1 error rates compared to the other models. Small sample type-1 error rates can be improved in beta regression models using bias correction/reduction methods. In the power experiments, variable-dispersion beta regression and fractional logit regression models have slightly elevated power compared to linear regression models. Similar results were observed if the

  20. Tank Vapor Characterization Project. Headspace vapor characterization of Hanford Waste Tank AX-102: Results from samples collected on June 27, 1995

    International Nuclear Information System (INIS)

    Clauss, T.W.; Pool, K.H.; Evans, J.C.; McVeety, B.D.; Thomas, B.L.; Olsen, K.B.; Fruchter, J.S.; Ligotke, M.W.

    1995-11-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-AX-102 (Tank AX-102) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank-farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest Laboratory (PNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. Detailed descriptions of the analytical results appear in the text

  1. Characterization of acid-base properties of two gibbsite samples in the context of literature results.

    Science.gov (United States)

    Adekola, F; Fédoroff, M; Geckeis, H; Kupcik, T; Lefèvre, G; Lützenkirchen, J; Plaschke, M; Preocanin, T; Rabung, T; Schild, D

    2011-02-01

    Two different gibbsites, one commercial and one synthesized according to a frequently applied recipe, were studied in an interlaboratory attempt to gain insight into the origin of widely differing reports on gibbsite acid-base surface properties. In addition to a thorough characterization of the two solids, several methods relevant to the interfacial charging were applied to the two samples: potentiometric titrations to obtain the "apparent" proton related surface charge density, zeta-potential measurements characterizing the potential at the plane of shear, and Attenuated Total Reflection Infrared Spectroscopy (ATR-IR) to obtain information on the variation of counter-ion adsorption with pH (using nitrate as a probe). Values of the IEP at 9-10 and 11.2-11.3 were found for the commercial and synthesized sample, respectively. The experimental observations revealed huge differences in the charging behavior between the two samples. Such differences also appeared in the titration kinetics. A detailed literature review revealed similar disparity with no apparent systematic trend. While previously the waiting time between additions had been advocated to explain such differences among synthesized samples, our results do not support such a conclusion. Instead, we find that the amount of titrant added in each aliquot appears to have a significant influence on the titration curves. While we can relate a number of observations to others, a number of open questions and contradictions remain. We suggest various processes, which can explain the observed behavior. Copyright © 2010 Elsevier Inc. All rights reserved.

  2. Results report. Sampling and analyses of gases and microorganisms in the water from MINICAN in 2007, 2008 and 2010

    Energy Technology Data Exchange (ETDEWEB)

    Lydmark, Sara; Hallbeck, Lotta (Microbial Analytics Sweden AB (Sweden))

    2011-04-15

    The MINICAN project is located at the depth of 450 m in the Aespoe Hard Rock Laboratory and was initiated to study how corrosion of the cast iron insert inside a perforated copper canister would evolve with time. Miniature canisters with different perforations and with and without bentonite buffer in steel cages were installed and monitored. Samples for microbiological and gas composition together with samples for groundwater chemistry have been analysed at three occasions in 2007, 2008 and 2010. The results show how the microbial populations outside the canisters have evolved from a mixture of microorganism able to grow on organic material, like heterotrophic organisms, and acetogens that grow on hydrogen gas and carbon dioxide in 2007, to populations with a large proportion of sulphate-reducing bacteria in 2010. The highest number of sulphate-reducing bacteria was found in MINICAN experiment A02C, canister with one hole at the top of the copper canister, in 2010 with 2.4 x 104 mL-1 followed by 8 x 103 mL-1 in A03 (hole in the bottom of the canister) and 7 x 103 mL-1 in A06 (two holes at the top and no bentonite). The numbers of culturable heterotrophic bacteria were between 200 and 530 mL-1 in the experiments with bentonite in 2007 but below detection in all experiments in 2010. The same trend was shown for acetogenes. Measurable amounts of hydrogen gas were found in all experiments at all sampling occasions. There was no general trend for the amounts of hydrogen but there was an increase in three of the experiments and in the groundwater outside MINICAN. It was found that the water chemistry differed between A06 and A02-A04 experiment by higher sulphate and chloride concentrations in A06 compared to the others. By plotting the concentrations of chloride, sulphate against time, a decrease in sulphate concentration was found in all canister experiments. The chloride concentrations were stable during the same period. On the other hand, an increase in sulphate

  3. Results report. Sampling and analyses of gases and microorganisms in the water from MINICAN in 2007, 2008 and 2010

    International Nuclear Information System (INIS)

    Lydmark, Sara; Hallbeck, Lotta

    2011-04-01

    The MINICAN project is located at the depth of 450 m in the Aespoe Hard Rock Laboratory and was initiated to study how corrosion of the cast iron insert inside a perforated copper canister would evolve with time. Miniature canisters with different perforations and with and without bentonite buffer in steel cages were installed and monitored. Samples for microbiological and gas composition together with samples for groundwater chemistry have been analysed at three occasions in 2007, 2008 and 2010. The results show how the microbial populations outside the canisters have evolved from a mixture of microorganism able to grow on organic material, like heterotrophic organisms, and acetogens that grow on hydrogen gas and carbon dioxide in 2007, to populations with a large proportion of sulphate-reducing bacteria in 2010. The highest number of sulphate-reducing bacteria was found in MINICAN experiment A02C, canister with one hole at the top of the copper canister, in 2010 with 2.4 x 10 4 mL -1 followed by 8 x 10 3 mL -1 in A03 (hole in the bottom of the canister) and 7 x 10 3 mL -1 in A06 (two holes at the top and no bentonite). The numbers of culturable heterotrophic bacteria were between 200 and 530 mL-1 in the experiments with bentonite in 2007 but below detection in all experiments in 2010. The same trend was shown for acetogenes. Measurable amounts of hydrogen gas were found in all experiments at all sampling occasions. There was no general trend for the amounts of hydrogen but there was an increase in three of the experiments and in the groundwater outside MINICAN. It was found that the water chemistry differed between A06 and A02-A04 experiment by higher sulphate and chloride concentrations in A06 compared to the others. By plotting the concentrations of chloride, sulphate against time, a decrease in sulphate concentration was found in all canister experiments. The chloride concentrations were stable during the same period. On the other hand, an increase in sulphate

  4. Performance of laboratories analysing welding fume on filter samples: results from the WASP proficiency testing scheme.

    Science.gov (United States)

    Stacey, Peter; Butler, Owen

    2008-06-01

    This paper emphasizes the need for occupational hygiene professionals to require evidence of the quality of welding fume data from analytical laboratories. The measurement of metals in welding fume using atomic spectrometric techniques is a complex analysis often requiring specialist digestion procedures. The results from a trial programme testing the proficiency of laboratories in the Workplace Analysis Scheme for Proficiency (WASP) to measure potentially harmful metals in several different types of welding fume showed that most laboratories underestimated the mass of analyte on the filters. The average recovery was 70-80% of the target value and >20% of reported recoveries for some of the more difficult welding fume matrices were welding fume trial filter samples. Consistent rather than erratic error predominated, suggesting that the main analytical factor contributing to the differences between the target values and results was the effectiveness of the sample preparation procedures used by participating laboratories. It is concluded that, with practice and regular participation in WASP, performance can improve over time.

  5. Procedure and results of a systematic comparative round robin estimation of the uncertainties of emission measurements in Germany and Switzerland during the summer and fall 1998

    Energy Technology Data Exchange (ETDEWEB)

    Morkowski, J.S.

    2000-08-01

    During summer and fall 1998, 75 sample takers and 20 employees of laboratories of 26 institutes measuring emissions in Germany and Switzerland estimated the uncertainty of measuring results of 5 selected DVI-standard emission measuring methods. The applied method of systematic comparative estimation showed that the estimated total uncertainties U{sub T} of the investigated measuring methods range between 12% and 21%. The results of the round robin estimation for one of the methods (dust measuring 2066 Part 7) with U{sub T}=15.4% are equal to those of the system for simulation of emissions (HLfU Kassel) with 15.5%. This confirms the expectation of the initiators of the project that the systematic comparative estimation is useful for the characterization of test methods and hence for the validation of methods. (orig.)

  6. Tank Vapor Characterization Project: Headspace vapor characterization of Hanford waste tank 241-S-101: Results from samples collected on 06/06/96

    International Nuclear Information System (INIS)

    Thomas, B.L.; Evans, J.C.; Pool, K.H.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-S-101. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained. Analyte concentrations were based on analytical results and sample volumes provided by WHC. A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed

  7. Intercomparison of methods for determining 90Sr and 137Cs in plant samples

    International Nuclear Information System (INIS)

    Sha Lianmao; Zhao Min; Tian Guizhi

    1986-01-01

    The results of intercomparison of methods for determining 90 Sr and 137 Cs in plant samples are reported. Nine laboratories participated in the intercomparison. The samples used in intercomparison were reed and tea powders. The analytical results of 90 Sr in reed and 137 Cs in tea from different laboratories show good comparability and follow the normal-distribution. Some results reported of 137 Cs in reed are apparently lower than others. The results of 90 Sr in tea from different laboratories have poor comparability. The results obtained by HDEHP rapid extraction chromatograph appear to be too high, and it's cause is discussed. The 95% confidence intervals of content of 90 Sr and 137 Cs in reed and tea samples are given

  8. Ocular-following responses to white noise stimuli in humans reveal a novel nonlinearity that results from temporal sampling.

    Science.gov (United States)

    Sheliga, Boris M; Quaia, Christian; FitzGibbon, Edmond J; Cumming, Bruce G

    2016-01-01

    White noise stimuli are frequently used to study the visual processing of broadband images in the laboratory. A common goal is to describe how responses are derived from Fourier components in the image. We investigated this issue by recording the ocular-following responses (OFRs) to white noise stimuli in human subjects. For a given speed we compared OFRs to unfiltered white noise with those to noise filtered with band-pass filters and notch filters. Removing components with low spatial frequency (SF) reduced OFR magnitudes, and the SF associated with the greatest reduction matched the SF that produced the maximal response when presented alone. This reduction declined rapidly with SF, compatible with a winner-take-all operation. Removing higher SF components increased OFR magnitudes. For higher speeds this effect became larger and propagated toward lower SFs. All of these effects were quantitatively well described by a model that combined two factors: (a) an excitatory drive that reflected the OFRs to individual Fourier components and (b) a suppression by higher SF channels where the temporal sampling of the display led to flicker. This nonlinear interaction has an important practical implication: Even with high refresh rates (150 Hz), the temporal sampling introduced by visual displays has a significant impact on visual processing. For instance, we show that this distorts speed tuning curves, shifting the peak to lower speeds. Careful attention to spectral content, in the light of this nonlinearity, is necessary to minimize the resulting artifact when using white noise patterns undergoing apparent motion.

  9. Comparison of sampling methods for hard-to-reach francophone populations: yield and adequacy of advertisement and respondent-driven sampling.

    Science.gov (United States)

    Ngwakongnwi, Emmanuel; King-Shier, Kathryn M; Hemmelgarn, Brenda R; Musto, Richard; Quan, Hude

    2014-01-01

    Francophones who live outside the primarily French-speaking province of Quebec, Canada, risk being excluded from research by lack of a sampling frame. We examined the adequacy of random sampling, advertising, and respondent-driven sampling for recruitment of francophones for survey research. We recruited francophones residing in the city of Calgary, Alberta, through advertising and respondentdriven sampling. These 2 samples were then compared with a random subsample of Calgary francophones derived from the 2006 Canadian Community Health Survey (CCHS). We assessed the effectiveness of advertising and respondent-driven sampling in relation to the CCHS sample by comparing demographic characteristics and selected items from the CCHS (specifically self-reported general health status, perceived weight, and having a family doctor). We recruited 120 francophones through advertising and 145 through respondent-driven sampling; the random sample from the CCHS consisted of 259 records. The samples derived from advertising and respondentdriven sampling differed from the CCHS in terms of age (mean ages 41.0, 37.6, and 42.5 years, respectively), sex (proportion of males 26.1%, 40.6%, and 56.6%, respectively), education (college or higher 86.7% , 77.9% , and 59.1%, respectively), place of birth (immigrants accounting for 45.8%, 55.2%, and 3.7%, respectively), and not having a regular medical doctor (16.7%, 34.5%, and 16.6%, respectively). Differences were not tested statistically because of limitations on the analysis of CCHS data imposed by Statistics Canada. The samples generated exclusively through advertising and respondent-driven sampling were not representative of the gold standard sample from the CCHS. Use of such biased samples for research studies could generate misleading results.

  10. Comparative analysis of bacterial profiles in unstimulated and stimulated saliva samples

    DEFF Research Database (Denmark)

    Belstrøm, Daniel; Holmstrup, Palle; Jensen, Allan Bardow

    2016-01-01

    BACKGROUND AND OBJECTIVE: The microbial profiles of stimulated saliva samples have been shown to differentiate between patients with periodontitis, patients with dental caries, and orally healthy individuals. Saliva was stimulated to allow for easy and rapid collection; however, microbial...

  11. Speeding Up Non-Parametric Bootstrap Computations for Statistics Based on Sample Moments in Small/Moderate Sample Size Applications.

    Directory of Open Access Journals (Sweden)

    Elias Chaibub Neto

    Full Text Available In this paper we propose a vectorized implementation of the non-parametric bootstrap for statistics based on sample moments. Basically, we adopt the multinomial sampling formulation of the non-parametric bootstrap, and compute bootstrap replications of sample moment statistics by simply weighting the observed data according to multinomial counts instead of evaluating the statistic on a resampled version of the observed data. Using this formulation we can generate a matrix of bootstrap weights and compute the entire vector of bootstrap replications with a few matrix multiplications. Vectorization is particularly important for matrix-oriented programming languages such as R, where matrix/vector calculations tend to be faster than scalar operations implemented in a loop. We illustrate the application of the vectorized implementation in real and simulated data sets, when bootstrapping Pearson's sample correlation coefficient, and compared its performance against two state-of-the-art R implementations of the non-parametric bootstrap, as well as a straightforward one based on a for loop. Our investigations spanned varying sample sizes and number of bootstrap replications. The vectorized bootstrap compared favorably against the state-of-the-art implementations in all cases tested, and was remarkably/considerably faster for small/moderate sample sizes. The same results were observed in the comparison with the straightforward implementation, except for large sample sizes, where the vectorized bootstrap was slightly slower than the straightforward implementation due to increased time expenditures in the generation of weight matrices via multinomial sampling.

  12. Thermodynamic and structural models compared with the initial dissolution rates of SON glass samples

    International Nuclear Information System (INIS)

    Tovena, I.; Advocat, T.; Ghaleb, D.; Vernaz, E.

    1993-01-01

    The experimentally determined initial dissolution rate R 0 of nuclear glass was correlated with thermodynamic parameters and structural parameters. The initial corrosion rates of six ''R7T7'' glass samples measured at 100 deg C in a Soxhlet device were correlated with the glass free hydration energy and the glass formation enthalpy. These correlations were then tested with a group of 26 SON glasses selected for their wide diversity of compositions. The thermodynamic models provided a satisfactory approximation of the initial dissolution rate determined under Soxhlet conditions for SON glass samples that include up to 15 wt% of boron and some alumina. Conversely, these models are inaccurate if the boron concentration exceeds 15 wt% and the glass contains no alumina. Possible correlations between R 0 and structural parameters, such as the boron coordination number and the number of nonbridging oxygen atoms, were also investigated. The authors show that R 0 varies inversely with the number of 4-coordinate boron atoms; conversely, the results do not substantiate published reports of a correlation between R 0 and the number of nonbridging oxygen atoms. (authors). 13 refs., 2 figs., 4 tabs

  13. Vapor space characterization of waste tank 241-TY-103: Results from samples collected on 4/11/95

    International Nuclear Information System (INIS)

    Ligotke, M.W.; Clauss, T.W.; Pool, K.H.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-TY-103 (referred to as Tank TY-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 16 were observed above the 5-ppbv reporting cutoff. Sixteen tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 95% of the total organic components in Tank TY-103. Two permanent gases, carbon dioxide (CO 2 ) and nitrous oxide (N 2 O), were also detected

  14. Vapor space characterization of Waste Tank 241-S-111: Results from samples collected on 3/21/95

    International Nuclear Information System (INIS)

    Klinger, G.S.; Clauss, T.W.; Ligotke, M.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-S-111 (referred to as Tank S-111). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, seven were observed above the 5-ppbv reporting cutoff. Five tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 98% of the total organic components in Tank S-111. Two permanent gases, hydrogen (H 2 ) and nitrous oxide (N 2 O), were also detected. Tank S-111 is on the Hydrogen Watch List

  15. Vapor space characterization of waste Tank 241-U-103: Results from samples collected on 2/15/95

    International Nuclear Information System (INIS)

    Ligotke, M.W.; Pool, K.H.; Clauss, T.W.; McVeety, B.D.; Klinger, G.S.; Olsen, K.B.; Bredt, O.P.; Fruchter, J.S.; Goheen, S.C.

    1995-11-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-U-103 (referred to as Tank U-103). The results described her were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water vapor (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 11 were observed above the 5-ppbv reporting cutoff. Eleven tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 90% of the total organic components in Tank U-103. Two permanent gases, hydrogen (H 2 ) and nitrous oxide (N 2 O), were also detected. Tank U-103 is on the Hydrogen Watch List

  16. Vapor space characterization of waste Tank 241-SX-106: Results from samples collected on 3/24/95

    International Nuclear Information System (INIS)

    Klinger, G.S.; Clauss, T.W.; Litgotke, M.W.

    1995-11-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-SX-106 (referred to as Tank SX-106). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 4 were observed above the 5-ppbv reporting cutoff. Three tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 7 organic analytes identified are listed in Table 1 and account for approximately 100% of the total organic components in Tank SX-106. Carbon dioxide (CO 2 ) was the only permanent gas detected. Tank SX-106 is on the Ferrocyanide Watch List

  17. Vapor space characterization of waste tank 241-TX-118: Results from samples collected on 12/16/94

    International Nuclear Information System (INIS)

    Lucke, R.B.; Ligotke, M.W.; McVeety, B.D.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-TX-118 (referred to as Tank TX-118). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 3 were observed above the 5-ppbv reporting cutoff. Twenty three organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv, and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 84% of the total organic components in Tank TX-118. Two permanent gases, carbon dioxide (CO 2 ) and nitrous oxide (N 2 O), were also detected

  18. Vapor space characterization of waste tank 241-S-102: Results from samples collected on 3/14/95

    International Nuclear Information System (INIS)

    Pool, K.H.; McVeety, B.D.; Clauss, T.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-S-102 (referred to as Tank S-102). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 11 were observed above the 5-ppbv reporting cutoff. Eleven tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 95% of the total organic components in Tank S-102. Two permanent gases, hydrogen (H 2 ) and nitrous oxide (N 2 O), were also detected

  19. Vapor space characterization of waste Tank 241-TY-101: Results from samples collected on 4/6/95

    International Nuclear Information System (INIS)

    Klinger, G.S.; Clauss, T.W.; Ligotke, M.W.; Pool, K.H.; McVeety, B.D.; Olsen, K.B.; Bredt, O.P.; Fruchter, J.S.; Goheen, S.C.

    1995-11-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-TY-101 (referred to as Tank TY-101). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water vapor (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Off these, 5 were observed above the 5-ppbv reporting cutoff. One tentatively identified compound (TIC) was observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The six organic analyses identified are listed in Table 1 and account for approximately 100% of the total organic components in Tank TY-101. Two permanent gases, carbon dioxide (CO 2 ) and nitrous oxide (N 2 O), were also detected. Tank TY-101 is on the Ferrocyanide Watch List

  20. Vapor space characterization of waste tank 241-BX-104: Results from samples collected on 12/30/94

    International Nuclear Information System (INIS)

    Pool, K.H.; Ligotke, M.W.; McVeety, B.D.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-BX-104 (referred to as Tank BX-104). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained. for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SOx) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 13 were observed above the 5-ppbv reporting cutoff. Sixty-six organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes, with the highest estimated concentrations are listed in Table 1 and account for approximately 70% of the total organic components in Tank BX-104. Two permanent gases, carbon dioxide (CO 2 ) and nitrous oxide (N 2 O), were also detected

  1. Comparing simulated and theoretical sampling distributions of the U3 person-fit statistic

    NARCIS (Netherlands)

    Emons, W.H.M.; Meijer, R.R.; Sijtsma, K.

    2002-01-01

    The accuracy with which the theoretical sampling distribution of van der Flier's person-.t statistic U3 approaches the empirical U3 sampling distribution is affected by the item discrimination. A simulation study showed that for tests with a moderate or a strong mean item discrimination, the Type I

  2. Quarterly sampling of the wetlands along the old F Area effluent ditch: August 1994

    International Nuclear Information System (INIS)

    Cummins, C.L.; Dixon, K.L.

    1994-08-01

    In August 1994, well point water and near-surface water samples were collected to characterize tritium and volatile organic compounds (VOC) in the wetlands along the old F-Area effluent ditch south of 643-E (old burial ground). The August sampling event was the third in a series of eight events. Groundwater flow paths suggest that compounds detected in water table wells around 643-E migrate towards the old F-Area effluent ditch and Fourmile Branch. Recent analytical results from well point and near-surface water sampling in the wetlands that comprise the old F-Area effluent ditch have shown that tritium and small quantities of VOCs are outcropping in the area. For this study, seven locations along the old F-Area effluent ditch were selected to be sampled. Well point samples were collected from all seven locations and near-surface water samples were collected at four locations. A secondary objective of this project was to compare VOC concentrations between the well points installed to depths of 6 to 8 ft and the near-surface water sampling buckets installed to depths of 1 to 2 ft. Based on differences in tritium concentrations at each location, it was determined that the sampling devices intercepted different groundwater flow paths. This negated direct comparison of analytical results between devices. However, when VOC concentrations measured at each well point and bucket location were normalized, based on the percent differences observed in tritium concentrations at that location, the resulting well point and bucket VOC concentrations were comparable in most cases. These results are consistent with the results from the three previous sampling events, and suggest that volatilization losses of VOCs from the buckets may be negligible. Since the results from the two sampling methodologies are not directly comparable, further sampling of the buckets is not planned

  3. Improved explosive collection and detection with rationally assembled surface sampling materials

    Energy Technology Data Exchange (ETDEWEB)

    Chouyyok, Wilaiwan; Bays, J. Timothy; Gerasimenko, Aleksandr A.; Cinson, Anthony D.; Ewing, Robert G.; Atkinson, David A.; Addleman, R. Shane

    2016-01-01

    Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

  4. Comparing simulated and theoretical sampling distributions of the U3 person-fit statistic

    NARCIS (Netherlands)

    Emons, Wilco H.M.; Meijer, R.R.; Sijtsma, Klaas

    2002-01-01

    The accuracy with which the theoretical sampling distribution of van der Flier’s person-fit statistic U3 approaches the empirical U3 sampling distribution is affected by the item discrimination. A simulation study showed that for tests with a moderate or a strong mean item discrimination, the Type I

  5. Prenatal cytogenetic diagnosis in Spain: analysis and evaluation of the results obtained from amniotic fluid samples during the last decade.

    Science.gov (United States)

    Mademont-Soler, Irene; Morales, Carme; Clusellas, Núria; Soler, Anna; Sánchez, Aurora

    2011-08-01

    Chromosome abnormalities are one of the main causes of congenital defects, and establishing their frequency according to the different clinical indications for invasive procedure during pregnancy is especially important for genetic counselling. We analyzed the results of 29,883 amniotic fluid samples referred to our laboratory for cytogenetic studies from 1998 to 2009, which constitutes the largest series of cytogenetic analysis performed on amniotic fluid samples in Spain. The number of samples received tended to increase from 1998 to 2005, but after 2005 it decreased substantially. Cytogenetic results were obtained in 99.5% of the samples, and the detected incidence of chromosome abnormalities was 2.9%. Of these, 48.1% consisted of classical autosomal aneuploidies, trisomy 21 being the most frequent one. The main clinical indications for amniocentesis were positive prenatal screening and advanced maternal age, but referral reasons with highest positive predictive values were, excluding parental chromosome rearrangement, increased nuchal translucency (9.2%) and ultrasound abnormalities (6.6%). In conclusion, performing the karyotype on amniotic fluid samples is a good method for the detection of chromosome abnormalities during pregnancy. The number of cytogenetic studies on amniotic fluid has now decreased, however, due to the implementation of first trimester prenatal screening for the detection of Down syndrome, which allows karyotyping on chorionic villus samples. Our results also show that both ultrasound abnormalities and increased nuchal translucency are excellent clinical indicators for fetal chromosome abnormality. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Waste tank vapor project: Vapor space characterization of waste tank 241-BY-104: Results from samples collected on June 24, 1994

    International Nuclear Information System (INIS)

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Pool, K.H.; Lucke, R.B.; Fruchter, J.S.; Goheen, S.C.

    1994-11-01

    This report describes results of the analyses of tank-headspace samples taken from Hanford waste Tank 241-BY-104 (referred to as Tank BY-104) on June 24, 1994. The Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze inorganic and organic samples collected from the tank headspace. The sample job was designated S4019 and was performed by WHC on June 24, 1994 using the vapor sampling system (VSS). The results of the analyses are expected to be used in the determination of safety and toxicological issues related to the tank-headspace gas as described in the WHC report entitled Data Quality Objectives for Generic In-Tank Health and Safety Vapor Issue Resolution, WHC-SD-WM-DQO-002, Rev. 0. Sampling devices, including 16 sorbent trains (for inorganic analyses), and 5 SUMMA trademark canisters (for organic analyses), were supplied to the WHC sampling staff on June 20, 1994. Samples were taken (by WHC) on June 24. The samples were returned from the field on June 27. The inorganic samples delivered to PNL on chain-of-custody (COC) 006893 included 16 sorbent trains as described in Tables 2.2, 2.3, and 2.4. Additional inorganic blank spikes were obtained from related sample jobs. SUMMA trademark samples delivered to PNL on COC 006896 included one ambient air sample, one ambient-air sample through the sampling system, and three tank-headspace SUMMA trademark canister samples. The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL laboratory record book 55408. Custody of the sorbent trains was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated (≤10 degrees C) temperature until the time of analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program

  7. X-ray scattering for the characterization of lyophilized breast tissue samples

    International Nuclear Information System (INIS)

    Elshemey, Wael M.; Mohamed, Fayrouz S.; Khater, Ibrahim M.

    2013-01-01

    This work investigates the possibility of characterizing breast cancer by measuring the X-ray scattering profiles of lyophilized excised breast tissue samples. Since X-ray scattering from water-rich tissue is dominated by scattering from water, the removal of water by lyophilization would enhance the characterization process. In the present study, X-ray scattering profiles of 22 normal, 22 malignant and 10 benign breast tissue samples are measured. The cut-offs of scatter diagrams, sensitivity, specificity and diagnostic accuracy of three characterization parameters (full width at half maximum (FWHM) for the peak at 1.1 nm −1 , area under curve (AUC), and ratio of 1st to 2nd scattering peak intensities (I 1 /I 2 %)) are calculated and compared to the data from non-lyophilized samples. Results show increased sensitivity (up to 100%) of the present data on lyophilized breast tissue samples compared to previously reported data for non-lyophilized samples while the specificity (up to 95.4%), diagnostic accuracy (up to 95.4%) and receiver operating characteristic (ROC) curve values (up to 0.9979) for both sets of data are comparable. The present study shows significant differences between normal samples and each of malignant and benign samples. Only subtle differences exist between malignant and benign lyophilized breast tissue samples where FWHM=0.7±0.1 and 0.8±0.3, AUC=1.3±0.2 and 1.4±0.2 and I 1 /I 2 %=44.9±11.0 and 52.4±7.6 for malignant and benign samples respectively. - Highlights: • X-ray scattering profiles of breast tissue samples are acquired. • Three X-ray profile characterization parameters are calculated. • The cut-offs, sensitivity, specificity and diagnostic accuracy are calculated. • They are compared to the data from non-lyophilized samples. • Results show increased sensitivity in case of lyophilized samples

  8. Spot sputum samples are at least as good as early morning samples for identifying Mycobacterium tuberculosis.

    Science.gov (United States)

    Murphy, Michael E; Phillips, Patrick P J; Mendel, Carl M; Bongard, Emily; Bateson, Anna L C; Hunt, Robert; Murthy, Saraswathi; Singh, Kasha P; Brown, Michael; Crook, Angela M; Nunn, Andrew J; Meredith, Sarah K; Lipman, Marc; McHugh, Timothy D; Gillespie, Stephen H

    2017-10-27

    The use of early morning sputum samples (EMS) to diagnose tuberculosis (TB) can result in treatment delay given the need for the patient to return to the clinic with the EMS, increasing the chance of patients being lost during their diagnostic workup. However, there is little evidence to support the superiority of EMS over spot sputum samples. In this new analysis of the REMoxTB study, we compare the diagnostic accuracy of EMS with spot samples for identifying Mycobacterium tuberculosis pre- and post-treatment. Patients who were smear positive at screening were enrolled into the study. Paired sputum samples (one EMS and one spot) were collected at each trial visit pre- and post-treatment. Microscopy and culture on solid LJ and liquid MGIT media were performed on all samples; those missing corresponding paired results were excluded from the analyses. Data from 1115 pre- and 2995 post-treatment paired samples from 1931 patients enrolled in the REMoxTB study were analysed. Patients were recruited from South Africa (47%), East Africa (21%), India (20%), Asia (11%), and North America (1%); 70% were male, median age 31 years (IQR 24-41), 139 (7%) co-infected with HIV with a median CD4 cell count of 399 cells/μL (IQR 318-535). Pre-treatment spot samples had a higher yield of positive Ziehl-Neelsen smears (98% vs. 97%, P = 0.02) and LJ cultures (87% vs. 82%, P = 0.006) than EMS, but there was no difference for positivity by MGIT (93% vs. 95%, P = 0.18). Contaminated and false-positive MGIT were found more often with EMS rather than spot samples. Surprisingly, pre-treatment EMS had a higher smear grading and shorter time-to-positivity, by 1 day, than spot samples in MGIT culture (4.5 vs. 5.5 days, P spot samples in those with unfavourable outcomes, there were no differences in smear or culture results, and positive results were not detected earlier in Kaplan-Meier analyses in either EMS or spot samples. Our data do not support the hypothesis that EMS

  9. Statistical conditional sampling for variable-resolution video compression.

    Directory of Open Access Journals (Sweden)

    Alexander Wong

    Full Text Available In this study, we investigate a variable-resolution approach to video compression based on Conditional Random Field and statistical conditional sampling in order to further improve compression rate while maintaining high-quality video. In the proposed approach, representative key-frames within a video shot are identified and stored at full resolution. The remaining frames within the video shot are stored and compressed at a reduced resolution. At the decompression stage, a region-based dictionary is constructed from the key-frames and used to restore the reduced resolution frames to the original resolution via statistical conditional sampling. The sampling approach is based on the conditional probability of the CRF modeling by use of the constructed dictionary. Experimental results show that the proposed variable-resolution approach via statistical conditional sampling has potential for improving compression rates when compared to compressing the video at full resolution, while achieving higher video quality when compared to compressing the video at reduced resolution.

  10. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  11. Water calorimetry with thermistor bridge operated in DC and AC mode: comparative results

    International Nuclear Information System (INIS)

    Guerra, A.S.; Laitano, R.F.; Petrocchi, A.

    1997-01-01

    An experimental study was carried out to find out the optimal conditions for measuring the output signal in a water calorimeter. To this end the thermistor bridge of the calorimeter was operated in AC and in DC mode, respectively. A comparative analysis of these two alternative methods was the made. In the AC mode measurement a lock-in amplifier based experimental assembly was used and compared to the more conventional system based on a high-sensitivty DC amplifier. The AC system resulted to be preferable as far as the short term and long term reproducibility is concerned. (orig.)

  12. Water calorimetry with thermistor bridge operated in DC and AC mode: comparative results

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, A S; Laitano, R F; Petrocchi, A [Ist. Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA, Roma (Italy)

    1997-09-01

    An experimental study was carried out to find out the optimal conditions for measuring the output signal in a water calorimeter. To this end the thermistor bridge of the calorimeter was operated in AC and in DC mode, respectively. A comparative analysis of these two alternative methods was the made. In the AC mode measurement a lock-in amplifier based experimental assembly was used and compared to the more conventional system based on a high-sensitivty DC amplifier. The AC system resulted to be preferable as far as the short term and long term reproducibility is concerned. (orig.)

  13. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, Jean-Marc; Deprez, Pierre H; Jenssen, Christian

    2017-01-01

    For pancreatic solid lesions, ESGE recommends performing endoscopic ultrasound (EUS)-guided sampling as first-line procedure when a pathological diagnosis is required. Alternatively, percutaneous sampling may be considered in metastatic disease.Strong recommendation, moderate quality evidence.In ...

  14. Sampling results, DNAPL monitoring well GW-727, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Quarterly report, 1995

    International Nuclear Information System (INIS)

    1996-05-01

    In January 1990, dense, non aqueous phase liquids (DNAPLs) were discovered at a depth of approximately 274 feet below ground surface along the southern border of the Y-12 Plant Burial Grounds. Immediately after the discovery, an investigation was conducted to assess the occurrence of DNAPL at the site and to make recommendations for further action. A major task in the work plan calls for the construction and installation of five multiport wells. This report summarizes purging and sampling activities for one of these multiport wells, GW-727, and presents analytical results for GW- 727. This report summarizes purging and sampling activities for GW-727 and presents analytical results for GW-727

  15. The JCO criticality accident at Tokai-mura, Japan: an overview of the sampling campaign and preliminary results

    International Nuclear Information System (INIS)

    Komura, K.; Yamamoto, M.; Muroyama, T.; Murata, Y.; Nakanishi, T.; Hoshi, M.; Takada, J.; Ishikawa, M.; Takeoka, S.; Kitagawa, K.; Suga, S.; Endo, S.; Tosaki, N.; Mitsugashira, T.; Hara, M.; Hashimoto, T.; Takano, M.; Yanagawa, Y.; Tsuboi, T.; Ichimasa, M.; Ichimasa, Y.; Imura, H.; Sasajima, E.; Seki, R.; Saito, Y.; Kondo, M.; Kojima, S.; Muramatsu, Y.; Yoshida, S.; Shibata, S.; Yonehara, H.; Watanabe, Y.; Kimura, S.; Shiraishi, K.; Ban-nai, T.; Sahoo, S.K.; Igarashi, Y.; Aoyama, M.; Hirose, K.; Uehiro, T.; Doi, T.; Tanaka, A.; Matsuzawa, T.

    2000-01-01

    A criticality accident occurred on September 30, 1999 at the uranium conversion facility of the JCO Company Ltd. in Tokai-mura, Japan. A collaborating scientific investigation team was organized in two groups, the first to carry out research on the environmental impact (the environmental research group) and the second to assess the radiation effects on residents (the biological research group). This report concerns only the activities of the environmental research group. Four investigative teams were sent on different dates to the accident site and its vicinity to collect samples. About 400 samples were collected and subjected to analysis. An outline of the sampling campaign is presented here along with a brief chronology of the accident and the preliminary key results obtained by the independent research group are summarised in this Special Issue of the Journal of Environmental Radioactivity

  16. Tank Vapor Characterization Project: Headspace vapor characterization of Hanford Waste Tank 241-C-204: Results from samples collected on 07/02/96

    International Nuclear Information System (INIS)

    Thomas, B.L.; Evans, J.C.; Pool, K.H.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-C-204 (Tank C-204) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in Table S.1. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples are also listed in Table S.1. Detailed descriptions of the analytical results appear in the appendices

  17. Tank Vapor Characterization Project: Headspace vapor characterization of Hanford Waste Tank 241-S-103: Results from samples collected on 06/12/96

    International Nuclear Information System (INIS)

    Evans, J.C.; Pool, K.H.; Thomas, B.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-S-103 (Tank S-103) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volumes provided by WHC. A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in Table S.1. The three highest concentration analytes detected in SUMMA trademark canister and triple sorbent trap samples are also listed in Table S.1. Detailed descriptions of the analytical results appear in the appendices

  18. The Lyman alpha reference sample. II. Hubble space telescope imaging results, integrated properties, and trends

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, Matthew; Östlin, Göran; Duval, Florent; Sandberg, Andreas; Guaita, Lucia; Melinder, Jens; Rivera-Thorsen, Thøger [Department of Astronomy, Oskar Klein Centre, Stockholm University, AlbaNova University Centre, SE-106 91 Stockholm (Sweden); Adamo, Angela [Max Planck Institute for Astronomy, Königstuhl 17, D-69117 Heidelberg (Germany); Schaerer, Daniel [Université de Toulouse, UPS-OMP, IRAP, F-31000 Toulouse (France); Verhamme, Anne; Orlitová, Ivana [Geneva Observatory, University of Geneva, 51 Chemin des Maillettes, CH-1290 Versoix (Switzerland); Mas-Hesse, J. Miguel; Otí-Floranes, Héctor [Centro de Astrobiología (CSIC-INTA), Departamento de Astrofísica, P.O. Box 78, E-28691 Villanueva de la Cañada (Spain); Cannon, John M.; Pardy, Stephen [Department of Physics and Astronomy, Macalester College, 1600 Grand Avenue, Saint Paul, MN 55105 (United States); Atek, Hakim [Laboratoire dAstrophysique, École Polytechnique Fédérale de Lausanne (EPFL), Observatoire, CH-1290 Sauverny (Switzerland); Kunth, Daniel [Institut d' Astrophysique de Paris, UMR 7095, CNRS and UPMC, 98 bis Bd Arago, F-75014 Paris (France); Laursen, Peter [Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, DK-2100 Copenhagen (Denmark); Herenz, E. Christian, E-mail: matthew@astro.su.se [Leibniz-Institut für Astrophysik (AIP), An der Sternwarte 16, D-14482 Potsdam (Germany)

    2014-02-10

    We report new results regarding the Lyα output of galaxies, derived from the Lyman Alpha Reference Sample, and focused on Hubble Space Telescope imaging. For 14 galaxies we present intensity images in Lyα, Hα, and UV, and maps of Hα/Hβ, Lyα equivalent width (EW), and Lyα/Hα. We present Lyα and UV radial light profiles and show they are well-fitted by Sérsic profiles, but Lyα profiles show indices systematically lower than those of the UV (n ≈ 1-2 instead of ≳ 4). This reveals a general lack of the central concentration in Lyα that is ubiquitous in the UV. Photometric growth curves increase more slowly for Lyα than the far ultraviolet, showing that small apertures may underestimate the EW. For most galaxies, however, flux and EW curves flatten by radii ≈10 kpc, suggesting that if placed at high-z only a few of our galaxies would suffer from large flux losses. We compute global properties of the sample in large apertures, and show total Lyα luminosities to be independent of all other quantities. Normalized Lyα throughput, however, shows significant correlations: escape is found to be higher in galaxies of lower star formation rate, dust content, mass, and nebular quantities that suggest harder ionizing continuum and lower metallicity. Six galaxies would be selected as high-z Lyα emitters, based upon their luminosity and EW. We discuss the results in the context of high-z Lyα and UV samples. A few galaxies have EWs above 50 Å, and one shows f{sub esc}{sup Lyα} of 80%; such objects have not previously been reported at low-z.

  19. The Lyman alpha reference sample. II. Hubble space telescope imaging results, integrated properties, and trends

    International Nuclear Information System (INIS)

    Hayes, Matthew; Östlin, Göran; Duval, Florent; Sandberg, Andreas; Guaita, Lucia; Melinder, Jens; Rivera-Thorsen, Thøger; Adamo, Angela; Schaerer, Daniel; Verhamme, Anne; Orlitová, Ivana; Mas-Hesse, J. Miguel; Otí-Floranes, Héctor; Cannon, John M.; Pardy, Stephen; Atek, Hakim; Kunth, Daniel; Laursen, Peter; Herenz, E. Christian

    2014-01-01

    We report new results regarding the Lyα output of galaxies, derived from the Lyman Alpha Reference Sample, and focused on Hubble Space Telescope imaging. For 14 galaxies we present intensity images in Lyα, Hα, and UV, and maps of Hα/Hβ, Lyα equivalent width (EW), and Lyα/Hα. We present Lyα and UV radial light profiles and show they are well-fitted by Sérsic profiles, but Lyα profiles show indices systematically lower than those of the UV (n ≈ 1-2 instead of ≳ 4). This reveals a general lack of the central concentration in Lyα that is ubiquitous in the UV. Photometric growth curves increase more slowly for Lyα than the far ultraviolet, showing that small apertures may underestimate the EW. For most galaxies, however, flux and EW curves flatten by radii ≈10 kpc, suggesting that if placed at high-z only a few of our galaxies would suffer from large flux losses. We compute global properties of the sample in large apertures, and show total Lyα luminosities to be independent of all other quantities. Normalized Lyα throughput, however, shows significant correlations: escape is found to be higher in galaxies of lower star formation rate, dust content, mass, and nebular quantities that suggest harder ionizing continuum and lower metallicity. Six galaxies would be selected as high-z Lyα emitters, based upon their luminosity and EW. We discuss the results in the context of high-z Lyα and UV samples. A few galaxies have EWs above 50 Å, and one shows f esc Lyα of 80%; such objects have not previously been reported at low-z.

  20. Tank 241-B-103 headspace gas and vapor characterization results for samples collected in February 1995

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-01-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  1. Tank 241-BX-104 headspace gas and vapor characterization results for samples collected in December 1994

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-01-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  2. Tank 241-U-203 headspace gas and vapor characterization results for samples collected in August 1995

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  3. Tank 241-C-106 headspace gas and vapor characterization results for samples collected in February 1994

    International Nuclear Information System (INIS)

    Hackaby, J.L.; Bratzel, D.R.

    1995-01-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  4. Tank 241-S-111 headspace gas and vapor characterization results for samples collected in March 1995

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  5. Tank 241-U-103 headspace gas and vapor characterization results for samples collected in February 1995

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-01-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  6. Tank 241-SX-106 headspace gas and vapor characterization results for samples collected in March 1995

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  7. Tank 241-C-104 headspace gas and vapor characterization results for samples collected in March 1994

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-01-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  8. Tank 241-TX-105 headspace gas and vapor characterization results for samples collected in December 1995

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-01-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  9. Tank 241-C-102 headspace gas and vapor characterization results for samples collected in August 1994

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  10. Tank 241-BY-112 headspace gas and vapor characterization results for samples collected in November 1994

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-01-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  11. Tank 241-T-111 headspace gas and vapor characterization results for samples collected in January 1995

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  12. Tank 241-SX-103 headspace gas and vapor characterization results for samples collected in March 1995

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  13. Tank 241-TY-104 headspace gas and vapor characterization results for samples collected in April 1995

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  14. Tank 241-C-110 headspace gas and vapor characterization results for samples collected in August 1994

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  15. Tank 241-C-101 headspace gas and vapor characterization results for samples collected in September 1994

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  16. Tank 241-C-107 headspace gas and vapor characterization results for samples collected in September 1994

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Bratzel, D.R.

    1995-01-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  17. Forensic Comparison of Soil Samples Using Nondestructive Elemental Analysis.

    Science.gov (United States)

    Uitdehaag, Stefan; Wiarda, Wim; Donders, Timme; Kuiper, Irene

    2017-07-01

    Soil can play an important role in forensic cases in linking suspects or objects to a crime scene by comparing samples from the crime scene with samples derived from items. This study uses an adapted ED-XRF analysis (sieving instead of grinding to prevent destruction of microfossils) to produce elemental composition data of 20 elements. Different data processing techniques and statistical distances were evaluated using data from 50 samples and the log-LR cost (C llr ). The best performing combination, Canberra distance, relative data, and square root values, is used to construct a discriminative model. Examples of the spatial resolution of the method in crime scenes are shown for three locations, and sampling strategy is discussed. Twelve test cases were analyzed, and results showed that the method is applicable. The study shows how the combination of an analysis technique, a database, and a discriminative model can be used to compare multiple soil samples quickly. © 2016 American Academy of Forensic Sciences.

  18. Genomic research with human samples. Points of view from scientists and research subjects about disclosure of results and risks of genomic research. Ethical and empirical approach.

    Science.gov (United States)

    Valle Mansilla, José Ignacio

    2011-01-01

    Biomedical researchers often now ask subjects to donate samples to be deposited in biobanks. This is not only of interest to researchers, patients and society as a whole can benefit from the improvements in diagnosis, treatment, and prevention that the advent of genomic medicine portends. However, there is a growing debate regarding the social and ethical implications of creating biobanks and using stored human tissue samples for genomic research. Our aim was to identify factors related to both scientists and patients' preferences regarding the sort of information to convey to subjects about the results of the study and the risks related to genomic research. The method used was a survey addressed to 204 scientists and 279 donors from the U.S. and Spain. In this sample, researchers had already published genomic epidemiology studies; and research subjects had actually volunteered to donate a human sample for genomic research. Concerning the results, patients supported more frequently than scientists their right to know individual results from future genomic research. These differences were statistically significant after adjusting by the opportunity to receive genetic research results from the research they had previously participated and their perception of risks regarding genetic information compared to other clinical data. A slight majority of researchers supported informing participants about individual genomic results only if the reliability and clinical validity of the information had been established. Men were more likely than women to believe that patients should be informed of research results even if these conditions were not met. Also among patients, almost half of them would always prefer to be informed about individual results from future genomic research. The three main factors associated to a higher support of a non-limited access to individual results were: being from the US, having previously been offered individual information and considering

  19. The performance of atmospheric pressure gas chromatography-tandem mass spectrometry compared to gas chromatography-high resolution mass spectrometry for the analysis of polychlorinated dioxins and polychlorinated biphenyls in food and feed samples.

    Science.gov (United States)

    Ten Dam, Guillaume; Pussente, Igor Cabreira; Scholl, Georges; Eppe, Gauthier; Schaechtele, Alexander; van Leeuwen, Stefan

    2016-12-16

    Recently, gas chromatography tandem mass spectrometry (GC-MS/MS) has been added in European Union (EU) legislation as an alternative to magnetic sector high resolution mass spectrometry (HRMS) for the analysis of dioxins and dioxin like polychlorinated biphenyls (dl-PCB) in food and feed. In this study the performance of APGC-MS/MS compared to GC-HRMS is investigated and compared with EU legislation. The study includes the legislative parameters, relative intermediate precision standard deviation (S Rw ,rel), trueness, sensitivity, linear range and ion ratio tolerance. In addition, over 200 real samples of large variety and spanning several orders of magnitude in concentration were analyzed by both techniques and the selectivity was evaluated by comparing chromatograms. The S Rw ,rel and trueness were evaluated using (in-house) reference samples and fulfill to EU legislation, though the S Rw ,rel was better with GC-HRMS. The sensitivity was considerably better than of GC-HRMS while the linear range was similar. Ion ratios were mostly within the tolerable range of ±15%. A (temporary unresolved) systematic deviation in ion ratio was observed for several congeners, yet this did not lead to exceeding of the maximum ion ratio limits. The APGC-MS/MS results for the non-dioxin-like-PCBs (ndl-PCBs) were negatively biased, particularly for PCB138 and 153 in contaminated samples. The selectivity of APGC-MS/MS was lower for several matrices. Particularly for contaminated samples, interfering peaks were observed in the APGC chromatograms of the native compounds (dioxins) and labeled internal standards (PCBs). These can lead to biased results and ultimately to false positive samples. It was concluded that the determination of dioxins and PCBs using APGC-MS/MS meets the requirements set by the European Commission. However, due to generally better selectivity and S Rw ,rel, GC-HRMS is the preferred method for monitoring purposes. Copyright © 2016 Elsevier B.V. All rights

  20. Tank vapor characterization project. Headspace vapor characterization of Hanford waste Tank SX-101: Results from samples collected on 07/21/95

    International Nuclear Information System (INIS)

    Evans, J.C.; Clauss, T.W.; McVeety, B.D.; Pool, K.H.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1996-05-01

    Results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank-farm operations. They include air concentrations of inorganic and organic analytes and grouped compounds from samples. The vapor concentrations are based either on whole-volume samples or on sorbent traps exposed to sample flow. No immediate notifications were needed because analytical results indicated no specific analytes exceeded notification levels. Summary of results: NH3, 3.8 ppmv; NO2, 0.10 ppmv; NO, 0.13 ppm; H2O, 11.8 mg/L; CO2, 338 ppmv; CO, 3 ; methanol, 0.060 ppmv; acetone, 0.033 ppmv; trichlorofluoromethane, 0.023 ppmv; and acetone, 0.034 ppmv

  1. Microplastic sampling with the AVANI trawl compared to two neuston trawls in the Bay of Bengal and South Pacific.

    Science.gov (United States)

    Eriksen, Marcus; Liboiron, Max; Kiessling, Tim; Charron, Louis; Alling, Abigail; Lebreton, Laurent; Richards, Heather; Roth, Barent; Ory, Nicolas C; Hidalgo-Ruz, Valeria; Meerhoff, Erika; Box, Carolynn; Cummins, Anna; Thiel, Martin

    2018-01-01

    Many typical neuston trawls can only be used during relatively calm sea states and slow tow speeds. During two expeditions to the Bay of Bengal and the eastern South Pacific we investigated whether the new, high-speed AVANI trawl (All-purpose Velocity Accelerated Net Instrument) collects similar amounts and types of microplastics as two established scientific trawl designs, the manta trawl and the DiSalvo neuston net. Using a 335 μm net, the AVANI trawl can collect microplastics from the sea surface at speeds up to 8 knots as it "skis" across the surface, whereas the manta and DiSalvo neuston trawls must be towed slowly in a less turbulent sea state and often represent shorter tow lengths. Generally, the AVANI trawl collected a greater numerical abundance and weight of plastic particles in most size classes and debris types than the manta trawl and DiSalvo neuston net, likely because these trawls only skim the surface layer while the AVANI trawl, moving vertically in a random fashion, collects a "deeper" sample, capturing the few plastics that float slightly lower in the water column. However, the samples did not differ enough that results were significantly affected, suggesting that studies done with these different trawls are comparable. The advantage of the AVANI trawl over traditional research trawls is that it allows for collection on vessels underway at high speeds and during long transits, allowing for a nearly continuous sampling effort over long distances. As local surface currents make sea surface abundance widely heterogeneous, widely spaced short-tow trawls, such as the manta and DiSalvo trawls, can catch or miss hotspots or meso-scale variability of microplastic accumulations, whereas the AVANI trawl, if utilized for back-to-back tows of intermediate distances (5-10 km), can bridge variable wind conditions and debris concentrations potentially reducing variance and provide a greater resolution of spatial distribution. Copyright © 2017 Elsevier Ltd

  2. Making the results of bottom-up energy savings comparable

    Directory of Open Access Journals (Sweden)

    Moser Simon

    2012-01-01

    Full Text Available The Energy Service Directive (ESD has pushed forward the issue of energy savings calculations without clarifying the methodological basis. Savings achieved in the Member States are calculated with rather non-transparent and hardly comparable Bottom-up (BU methods. This paper develops the idea of parallel evaluation tracks separating the Member States’ issue of ESD verification and comparable savings calculations. Comparability is ensured by developing a standardised BU calculation kernel for different energy efficiency improvement (EEI actions which simultaneously depicts the different calculation options in a structured way (e.g. baseline definition, system boundaries, double counting. Due to the heterogeneity of BU calculations the approach requires a central database where Member States feed in input data on BU actions according to a predefined structure. The paper demonstrates the proposed approach including a concrete example of application.

  3. Peptide receptor radionuclide therapy (PRRT) using Lu-177 DOTA-NOC and Lu-177 DOTA-TATE: Comparative results

    International Nuclear Information System (INIS)

    Wehrmann, C.; Senftleben, S.; Baum, R.P.

    2007-01-01

    Full text: Aim: One of the few treatment options for inoperable neuroendocrine tumors (NET) is peptide receptor radiotherapy with somatostatin analogues. DOTA-NOC shows the highest affinity to the somatostatin receptors (sstr) 3 and 5 and a very high affinity to sstr 2. We compared the dosimetric parameters uptake, half-life (kinetics) and mean absorbed organ and tumor doses of 177 Lu DOTANOC and 177 Lu DOTA-TATE. Methods: 139 patients with neuroendocrine tumors with high sstr expression (verified by Ga-68 DOTA-NOC PET/CT) were studied. 130 patients (57m, 73f; aged 60±11a) were treated with 2.5-7.4 GBq Lu-177 DOTA-TATE and 9 patients (3m, 6f, aged 64±10a) with 3.6-7.4 GBq Lu-177 DOTA-NOC. Whole-body scans were performed after 0.5h, 3h, 24h, 48h, 72h and 96h p.i. Blood samples from 23 patients were obtained after therapy. By means of geometric mean and after background correction, ROI results were used to calculate the estimated absorbed organ and tumor doses according to the MIRD-scheme (OLINDA software). Results: Lu-177 DOTA-NOC showed a higher uptake as compared to Lu-177 DOTATATE (=100%): for whole-body about 38% and in normal tissue 36%, in the spleen 17% and in the kidneys 18%. The tumor uptake was about 5% higher for DOTA-TATE. The effective half-life for whole-body was comparable for both peptides (t1/2a NOC 2.9h vs. TATE 2.4h and t1/2b NOC 54h vs. TATE 56h). In normal tissue, t1/2a was similar (NOC 3.3h; TATE 2.6h) but the t1/2b was longer for DOTA-TATE (NOC 43h; TATE 48h). t1/2b was longer for DOTA-NOC in the spleen (NOC 81h; TATE 72h) and in the kidney (NOC 68.1h; TATE 65h). The mean absorbed dose in the kidney (TATE 5Sv; NOC 6Sv) and spleen (TATE 7Sv; NOC 8Sv) was higher for DOTA-NOC. In the tumor, the t1/2b was higher for DOTA-TATE (NOC 65h; TATE 77h). For DOTA-TATE the whole-body dose was lower (0.27Sv) as compared to DOTA-NOC (0.38 Sv) (significant by unpaired sign test). The estimated mean absorbed tumor doses were 47+/-66 Sv for DOTA-TATE and 35

  4. Comparing Trauma Exposure, Mental Health Needs, and Service Utilization Across Clinical Samples of Refugee, Immigrant, and U.S.-Origin Children.

    Science.gov (United States)

    Betancourt, Theresa S; Newnham, Elizabeth A; Birman, Dina; Lee, Robert; Ellis, B Heidi; Layne, Christopher M

    2017-06-01

    Most mental health services for trauma-exposed children and adolescents were not originally developed for refugees. Information is needed to help clinicians design services to address the consequences of trauma in refugee populations. We compared trauma exposure, psychological distress, and mental health service utilization among children and adolescents of refugee-origin, immigrant-origin, and U.S.-origin referred for assessment and treatment by U.S. providers in the National Child Traumatic Stress Network (NCTSN). We used propensity score matching to compare trauma profiles, mental health needs, and service use across three groups. Our sample comprised refugee-origin youth (n = 60, 48.3% female, mean age = 13.07 years) and propensity-matched samples of immigrant-origin youth (n = 143, 60.8% female, mean age = 13.26 years), and U.S.-origin youth (n = 140, 56.1% female, mean age = 12.11 years). On average, there were significantly more types of trauma exposure among refugee youth than either U.S.-origin youth (p refugee youth had higher rates of community violence exposure, dissociative symptoms, traumatic grief, somatization, and phobic disorder.  In contrast, the refugee group had comparably lower rates of substance abuse and oppositional defiant disorder (ps ranging from .030 to refugee-origin youth presented with distinct patterns of trauma exposure, distress symptoms, and service needs that merit consideration in services planning. Copyright © 2017 International Society for Traumatic Stress Studies.

  5. Sample Selection for Training Cascade Detectors.

    Science.gov (United States)

    Vállez, Noelia; Deniz, Oscar; Bueno, Gloria

    2015-01-01

    Automatic detection systems usually require large and representative training datasets in order to obtain good detection and false positive rates. Training datasets are such that the positive set has few samples and/or the negative set should represent anything except the object of interest. In this respect, the negative set typically contains orders of magnitude more images than the positive set. However, imbalanced training databases lead to biased classifiers. In this paper, we focus our attention on a negative sample selection method to properly balance the training data for cascade detectors. The method is based on the selection of the most informative false positive samples generated in one stage to feed the next stage. The results show that the proposed cascade detector with sample selection obtains on average better partial AUC and smaller standard deviation than the other compared cascade detectors.

  6. Re-sampling of the KLX02 deep borehole at Laxemar

    International Nuclear Information System (INIS)

    Laaksoharju, M.; Andersson, Cecilia; Tullborg, E.L.; Wallin, B.; Ekwall, K.; Pedersen, K.

    1999-01-01

    The project focuses on the origin and changes of deep groundwaters, which are important for understanding the stability of the groundwater surrounding the final repository. The results from the sampling campaign in 1997 down to a depth of 1500m are compared with the results from 1993 sampled in the same borehole. The analytical results and some preliminary calculations are presented. The changes since the last sampling campaign 4 years ago indicate a high degree of mixing and dynamics in the system. The following conclusions are drawn: More changes in the water composition than expected compared with the results from the sampling campaign in 1993; Larger portions of meteoric water in the upper part of the borehole; Less glacial water in the intermediate part of the borehole; More brine water in the lower part of the borehole. The conclusion is that there has been a relatively large change in the groundwater system during the last 4 years in the Laxemar deep borehole. The disturbance removed the effect from the last glaciation and pulled in groundwater, which resulted in a mixture mainly consisting of meteoric and brine waters. The most probable reason is that the annual fluctuation and flow in the open borehole play an important role as a modificator especially for the isotopes. The results show the sensitivity of deep groundwater to changes in the prevailing hydrogeological situation

  7. A comparative study of multilayer perceptron neural networks for the identification of rhubarb samples.

    Science.gov (United States)

    Zhang, Zhuoyong; Wang, Yamin; Fan, Guoqiang; Harrington, Peter de B

    2007-01-01

    Artificial neural networks have gained much attention in recent years as fast and flexible methods for quality control in traditional medicine. Near-infrared (NIR) spectroscopy has become an accepted method for the qualitative and quantitative analyses of traditional Chinese medicine since it is simple, rapid, and non-destructive. The present paper describes a method by which to discriminate official and unofficial rhubarb samples using three layer perceptron neural networks applied to NIR data. Multilayer perceptron neural networks were trained with back propagation, delta-bar-delta and quick propagation algorithms. Results obtained using these methods were all satisfactory, but the best outcomes were obtained with the delta-bar-delta algorithm.

  8. Evaluation of Respondent-Driven Sampling

    Science.gov (United States)

    McCreesh, Nicky; Frost, Simon; Seeley, Janet; Katongole, Joseph; Tarsh, Matilda Ndagire; Ndunguse, Richard; Jichi, Fatima; Lunel, Natasha L; Maher, Dermot; Johnston, Lisa G; Sonnenberg, Pam; Copas, Andrew J; Hayes, Richard J; White, Richard G

    2012-01-01

    Background Respondent-driven sampling is a novel variant of link-tracing sampling for estimating the characteristics of hard-to-reach groups, such as HIV prevalence in sex-workers. Despite its use by leading health organizations, the performance of this method in realistic situations is still largely unknown. We evaluated respondent-driven sampling by comparing estimates from a respondent-driven sampling survey with total-population data. Methods Total-population data on age, tribe, religion, socioeconomic status, sexual activity and HIV status were available on a population of 2402 male household-heads from an open cohort in rural Uganda. A respondent-driven sampling (RDS) survey was carried out in this population, employing current methods of sampling (RDS sample) and statistical inference (RDS estimates). Analyses were carried out for the full RDS sample and then repeated for the first 250 recruits (small sample). Results We recruited 927 household-heads. Full and small RDS samples were largely representative of the total population, but both samples under-represented men who were younger, of higher socioeconomic status, and with unknown sexual activity and HIV status. Respondent-driven-sampling statistical-inference methods failed to reduce these biases. Only 31%-37% (depending on method and sample size) of RDS estimates were closer to the true population proportions than the RDS sample proportions. Only 50%-74% of respondent-driven-sampling bootstrap 95% confidence intervals included the population proportion. Conclusions Respondent-driven sampling produced a generally representative sample of this well-connected non-hidden population. However, current respondent-driven-sampling inference methods failed to reduce bias when it occurred. Whether the data required to remove bias and measure precision can be collected in a respondent-driven sampling survey is unresolved. Respondent-driven sampling should be regarded as a (potentially superior) form of convenience-sampling

  9. The Estimation of Knowledge Solidity Based on the Comparative Analysis of Different Test Results

    Directory of Open Access Journals (Sweden)

    Y. K. Khenner

    2012-01-01

    Full Text Available At present, the testing techniques of knowledge estimation are widely spread in educational system. However, this method is seriously criticized including its application to the Unified State Examinations. The research is aimed at studying the limitations of testing techniques. The authors recommend a new way of knowledge solid- ity estimation bases on the comparative results analysis of various kinds of tests. While testing the large group of students, the authors found out that the results of the closed and open tests substantially differ. The comparative analysis demonstrates that the open tests assessment of the knowledge solidity is more adequate than that of the closed ones. As the research is only based on a single experiment, the authors recommend using this method further, substantiating the findings concerning the differences in tests results, and analyzing the advantages and disadvantages of the tests in question. 

  10. Uncertainty analysis in comparative NAA applied to geological and biological matrices

    International Nuclear Information System (INIS)

    Zahn, Guilherme S.; Ticianelli, Regina B.; Lange, Camila N.; Favaro, Deborah I.T.; Figueiredo, Ana M.G.

    2015-01-01

    Comparative nuclear activation analysis is a multielemental primary analytical technique that may be used in a rather broad spectrum of matrices with minimal-to-none sample preprocessing. Although the total activation of a chemical element in a sample depends on a rather large set of parameters, when the sample is irradiated together with a well-known comparator, most of these parameters are crossed out and the concentration of that element can be determined simply by using the activities and masses of the comparator and the sample, the concentration of this chemical element in the sample, the half-life of the formed radionuclide and the time between counting the sample and the comparator. This simplification greatly reduces not only the calculations required, but also the uncertainty associated with the measurement; nevertheless, a cautious analysis must be carried out in order to make sure all relevant uncertainties are properly treated, so that the final result can be as representative of the measurement as possible. In this work, this analysis was performed for geological matrices, where concentrations of the interest nuclides are rather high, but so is the density and average atomic number of the sample, as well as for a biological matrix, in order to allow for a comparison. The results show that the largest part of the uncertainty comes from the activity measurements and from the concentration of the comparator, and that while the influence of time-related terms in the final uncertainty can be safely neglected, the uncertainty in the masses may be relevant under specific circumstances. (author)

  11. Uncertainty analysis in comparative NAA applied to geological and biological matrices

    Energy Technology Data Exchange (ETDEWEB)

    Zahn, Guilherme S.; Ticianelli, Regina B.; Lange, Camila N.; Favaro, Deborah I.T.; Figueiredo, Ana M.G., E-mail: gzahn@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Comparative nuclear activation analysis is a multielemental primary analytical technique that may be used in a rather broad spectrum of matrices with minimal-to-none sample preprocessing. Although the total activation of a chemical element in a sample depends on a rather large set of parameters, when the sample is irradiated together with a well-known comparator, most of these parameters are crossed out and the concentration of that element can be determined simply by using the activities and masses of the comparator and the sample, the concentration of this chemical element in the sample, the half-life of the formed radionuclide and the time between counting the sample and the comparator. This simplification greatly reduces not only the calculations required, but also the uncertainty associated with the measurement; nevertheless, a cautious analysis must be carried out in order to make sure all relevant uncertainties are properly treated, so that the final result can be as representative of the measurement as possible. In this work, this analysis was performed for geological matrices, where concentrations of the interest nuclides are rather high, but so is the density and average atomic number of the sample, as well as for a biological matrix, in order to allow for a comparison. The results show that the largest part of the uncertainty comes from the activity measurements and from the concentration of the comparator, and that while the influence of time-related terms in the final uncertainty can be safely neglected, the uncertainty in the masses may be relevant under specific circumstances. (author)

  12. Men who have sex with men in Great Britain: comparing methods and estimates from probability and convenience sample surveys

    OpenAIRE

    Prah, Philip; Hickson, Ford; Bonell, Chris; McDaid, Lisa M; Johnson, Anne M; Wayal, Sonali; Clifton, Soazig; Sonnenberg, Pam; Nardone, Anthony; Erens, Bob; Copas, Andrew J; Riddell, Julie; Weatherburn, Peter; Mercer, Catherine H

    2016-01-01

    Objective: To examine sociodemographic and behavioural differences between men whohave sex with men (MSM) participating in recent UK convenience surveys and a national probability sample survey.\\ud Methods: We compared 148 MSM aged 18–64 years interviewed for Britain's third National Survey of Sexual Attitudes and Lifestyles (Natsal-3) undertaken in 2010–2012, with men inthe same age range participating in contemporaneous convenience surveys of MSM: 15 500 British resident men in the European...

  13. Introduction to SamplerCompare

    Directory of Open Access Journals (Sweden)

    Madeleine B. Thompson

    2011-08-01

    Full Text Available SamplerCompare is an R package for comparing the performance of Markov chain Monte Carlo (MCMC samplers. It samples from a collection of distributions with a collection of MCMC methods over a range of tuning parameters. Then, using log density evaluations per uncorrelated observation as a figure of merit, it generates a grid of plots showing the results of the simulation. It comes with a collection of predefined distributions and samplers and provides R and C interfaces for defining additional ones. It also provides the means to import simulation data generated by external systems. This document provides background on the package and demonstrates the basics of running simulations, visualizing results, and defining distributions and samplers in R.

  14. Tank Vapor Characterization Project: Headspace vapor characterization of Hanford Tank 241-S-107: Results from samples collected on 06/18/96

    International Nuclear Information System (INIS)

    Pool, K.H.; Evans, J.C.; Thomas, B.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of the waste storage tank 241-S-107 (Tank S-107) at the Hanford Site in Washington State. The results described in this report were obtained to characterize the vapors present in the tank headspace and to support safety evaluations and tank farm operations. The results include air concentrations of selected inorganic and organic analytes and grouped compounds from samples obtained by Westinghouse Hanford Company (WHC) and provided for analysis to Pacific Northwest National. Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, on sample volumes provided by WHC. A summary of the inorganic analytes, permanent gases, and total non-methane organic compounds is listed in Table S.1. Detailed descriptions of the analytical results appear in the appendices

  15. Evaluation of NAA laboratory results in inter-comparison on determination of trace elements in food and environmental samples

    International Nuclear Information System (INIS)

    Diah Dwiana Lestiani; Syukria Kurniawati; Natalia Adventini

    2012-01-01

    Inter-comparison program is a good tool for improving quality and to enhance the accuracy and precision of the analytical techniques. By participating in this program, laboratories could demonstrate their capability and ensuring the quality of analysis results generated by analytical laboratories. The Neutron Activation Analysis (NAA) laboratory at National Nuclear Energy Agency of Indonesia (BATAN), Nuclear Technology Center for Materials and Radiometry-PTNBR laboratory participated in inter-comparison tests organized by NAA working group. Inter-comparison BATAN 2009 was the third inter-laboratory analysis test within that project. The participating laboratories were asked to analyze for trace elements using neutron activation analysis as the primary technique. Three materials were distributed to the participants representing foodstuff, and environmental material samples. Samples were irradiated in rabbit facility of G.A. Siwabessy reactor with neutron flux ~ 10 13 n.cm -2 .s -1 , and counted with HPGe detector of gamma spectrometry. Several trace elements in these samples were detected. The accuracy and precision evaluation based on International Atomic Energy Agency (IAEA) criteria was applied. In this paper the PTNBR NAA laboratory results is evaluated. (author)

  16. Comparing the erosive effect of Iranian soft drinks with standard samples; A Calcium ion analysis

    Directory of Open Access Journals (Sweden)

    Fallahinejad Ghajari M.

    2007-05-01

    Full Text Available Background and Aim: Extensive and continuous consumption of acidic drinks is the main cause of enamel erosion in human teeth. The purpose of this study was to compare the erosive potential of two Iranian drinks with those of two imported ones. Materials and Methods: Two Iranian drinks (Cola Zamzam and Orange Zamzam and two imported ones (Pepsi and Miranda were studied in this experimental invitro study. 120 intact premolar teeth, extracted for orthodontic reasons were divided into 3 equal groups (A, B and C. Each group was exposed to one of the drinks for exposure times of: A: 15 minutes, B: 45 minutes and C: 12 hours. Each group was divided into 4 subgroups (each containing 10 teeth, which were exposed to 20 ml of one of the 4 drinks. The exposed surface was the same in all samples (a 5 mm in diameter semi circular window. The amount of Ca++ ion (mg/ml added to each drink at the end of exposure time was estimated by atomic absorption spectrophotometer. Results: 2 way ANOVA showed that the drinks were significantly different with regard to released Calcium ion. Time had significant effect on erosive potential. The two mentioned factors had significant interaction (P<0.001. The most erosive effect was seen in 12 hours in all of the drinks. The erosive effect of Orange Zamzam in 15 minutes and Pepsi in 45 minutes and 12 hours was significantly more than other groups (P<0.001. Conclusions: Pepsi had the most long term erosive effect among the four drinks, and Cola Zamzam had the least erosive potential.

  17. Sampling Strategies and Processing of Biobank Tissue Samples from Porcine Biomedical Models.

    Science.gov (United States)

    Blutke, Andreas; Wanke, Rüdiger

    2018-03-06

    In translational medical research, porcine models have steadily become more popular. Considering the high value of individual animals, particularly of genetically modified pig models, and the often-limited number of available animals of these models, establishment of (biobank) collections of adequately processed tissue samples suited for a broad spectrum of subsequent analyses methods, including analyses not specified at the time point of sampling, represent meaningful approaches to take full advantage of the translational value of the model. With respect to the peculiarities of porcine anatomy, comprehensive guidelines have recently been established for standardized generation of representative, high-quality samples from different porcine organs and tissues. These guidelines are essential prerequisites for the reproducibility of results and their comparability between different studies and investigators. The recording of basic data, such as organ weights and volumes, the determination of the sampling locations and of the numbers of tissue samples to be generated, as well as their orientation, size, processing and trimming directions, are relevant factors determining the generalizability and usability of the specimen for molecular, qualitative, and quantitative morphological analyses. Here, an illustrative, practical, step-by-step demonstration of the most important techniques for generation of representative, multi-purpose biobank specimen from porcine tissues is presented. The methods described here include determination of organ/tissue volumes and densities, the application of a volume-weighted systematic random sampling procedure for parenchymal organs by point-counting, determination of the extent of tissue shrinkage related to histological embedding of samples, and generation of randomly oriented samples for quantitative stereological analyses, such as isotropic uniform random (IUR) sections generated by the "Orientator" and "Isector" methods, and vertical

  18. Studies of U in the blood of two population samples

    International Nuclear Information System (INIS)

    Segovia, N.; Olguin, M.E.; Romero, M.

    1986-01-01

    The present work, attempts to establish the statistical distribution of blood uranium in a population of the same community, similar in age and in living patterns. U traces were evaluated by a fission track technique both in whole blood and plasma samples. Dried samples were compressed into pellets and irradiated in a nuclear reactor using the external detector method. For U quantification, standard U samples were used. A comparative sampling of U content in blood samples from a group of radiation exposed workers and another of leukemia patients was also carried out. Results from the sampling groups are reported and discussed. (author)

  19. Monitoring of radiation in airdust, deposition and an overall country milk sample. Results in the Netherlands in 1996

    International Nuclear Information System (INIS)

    Overwater, R.M.W.; Aldenkamp, F.J.; Drost, R.M.S; Glastra, P.; Hiemastra, Y.S.; Kik, M.J.; Koolwijk, A.C.; Koolwijk, A.C.; Kwakman, P.J.M.; Koops, J.C.; Van Lunenburg, A.P.P.A.; Nissan, L.; Ockhuizen, A.; Reinen, H.A.J.M.; Tax, R.B.; Tijsmans, M.H.; Van Zanten, R.

    1998-02-01

    The results of radiation measurements of the atmosphere in the Netherlands by the RIVM Laboratory of Radiation Research (LSO) are presented for the year 1996. The programme of RIVM/LSO includes samples of airdust and deposition taken at the RIVM premises in Bilthoven, Netherlands. An overall country milk sample, a mixture of milk samples from four milk factories in the Netherlands, was also analysed. In 1996, the yearly average gross alpha-activity and gross beta-activity concentrations in airdust sampled with a high volume sampler were 0.0671 ± 0.0009 (SD 0.03) and 0.540 ± 0.003 (SD 0.33) mBq.m -3 , where SD illustrates the variation in weekly averages during the year. These values are of the same order as those of the period 1992-1995. The yearly average activity concentrations in airdust, measured using gamma-spectroscopy, for the nuclides 7Be, 137Cs and 210Pb were 3890 ± 50 (SD 1320), 1.60 ± 0.03 (SD 1.2) and 500 ± 10 (SD 390) mBq.m-3. The yearly total gross alpha- and gross beta-activities of the deposition in Bilthoven, Netherlands, were 16.4 ± 1.5 and 67 ± 5 Bq.m-2, and the yearly total deposition of 3H was 970 ± 50 Bq.m-2. The total activities of 137Cs, 7Be and 210Pb in deposition were 0.55 ± 0.03, 920 ± 20 and 64.9 ± 1.6 Bq.m-2, respectively. The 210Pb-analysis and 210Po-analysis results obtained using alpha-spectroscopy were 57 ± 3 and 9 ± 2 Bq.m-2. These activities are all of the same order as those in previous years. The yearly average concentration of 137Cs in consumer milk from a nationwide sample mix was 0.073 ± 0.010 Bq.L-1, which is almost equal to that of the previous year. The results for 90Sr are lower than the detection limit of 0.2 Bq.L-1. 22 refs

  20. Test Capability of Comparative NAA Method in Analysis of Long Lived Element in SRM 1648

    International Nuclear Information System (INIS)

    Sri-Wardani

    2005-01-01

    The comparative NAA method had been examine on the analysis of long-lived elements content in air particulate sample of NIST.SRM 1648 for evaluation of a capability of comparative NAA method that used at P2TRR. From the result of analysis it could be determined analysis elements contained in the sample, namely: Sc, Co, Zn, Br, Rb, Sb, Hf and Th with optimum results in bias of 10%. The optimum result of long-lived elements obtained on a good accuracy and precision. From the analysis data obtained showed that the comparative NAA method with Gamma Trac and APTEC software capable to analyze several kinds of elements in environmental samples. Therefore, this method could be implement in biological and healthy samples. (author)

  1. Quality of claims, references and the presentation of risk results in medical journal advertising: a comparative study in Australia, Malaysia and the United States

    Directory of Open Access Journals (Sweden)

    Vitry Agnes I

    2010-05-01

    Full Text Available Abstract Background Journal advertising is used by pharmaceutical companies to disseminate medicine information to doctors. The quality of claims, references and the presentation of risk results in Australia and the US has been questioned in several studies. No recent evidence is available on the quality of claims, references and the presentation of risk results in journal advertising in Australia and the US and no Malaysian data have been published. The aim of this study was to compare the quality of claims, references and the presentation of risk results in journal advertising in these three countries. Methods A consecutive sample of 85 unique advertisements from each country was selected from journal advertising published between January 2004 to December 2006. Claims, references and the presentation of risk results in medical journal advertising were compared between the three countries. Results Less than one-third of the claims were unambiguous claims (Australia, 30%, Malaysia 17%, US, 23%. In Malaysia significantly less unambiguous claims were provided than in Australia and the US (P Conclusions The majority of claims were vague suggesting poor quality of claims in journal advertising in these three countries. Evidence from a randomized controlled trial, systematic review or meta- analysis was commonly cited to support claims. However, the more frequent use of data that have not been published and independently reviewed in the US compared to Australia and Malaysia raises questions on the quality of references in the US. The use of relative rather than absolute benefits may overemphasize the benefit of medicines which may leave doctors susceptible to misinterpreting information.

  2. The inspirations with a radioactive intercomparison on a wine sample

    International Nuclear Information System (INIS)

    Su Qiong

    1993-12-01

    The methods used and results in a radioactive intercomparison on a wine sample are reported, which was organized by WHO-IRC in May, 1992. In order to analyse and compare the results obtained by all laboratories from WHO-IRC report (IRC NOTE No.41, 1993) are given. A re-measured new result about nuclide 40 K in the sample is also reported which coincides quite well with the result reported to IRC in a deviation of less than +-1%. And the problems concerning 'reference values' and standard sources etc. are also discussed

  3. Vapor space characterization of Waste Tank 241-U-106 (in situ): Results from samples collected on 8/25/94

    International Nuclear Information System (INIS)

    Ligotke, M.W.; Lucke, R.B.; Pool, K.H.

    1995-10-01

    This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-U-106 (referred to as Tank U-106). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), and water (H 2 O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO x ) was not performed. In addition, the authors looked for the 39 TO-14 compounds plus an additional 14 target analytes. Of these, six were observed above the 5-ppbv reporting cutoff. Ten organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv in two or more of the three samples collected and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 89% of the total organic components in Tank U-106. Methyl isocyanate, a compound of possible concern in Tank U-106, was not detected. Tank U-106 is on the Organic Watch List

  4. Prompt Gamma Ray Analysis of Soil Samples

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A.; Khiari, F.Z.; Haseeb, S.M.A.; Hussein, Tanvir; Khateeb-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Isab, A.H. [Department of Chemistry, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2015-07-01

    Neutron moderation effects were measured in bulk soil samples through prompt gamma ray measurements from water and benzene contaminated soil samples using 14 MeV neutron inelastic scattering. The prompt gamma rays were measured using a cylindrical 76 mm x 76 mm (diameter x height) LaBr{sub 3}:Ce detector. Since neutron moderation effects strongly depend upon hydrogen concentration of the sample, for comparison purposes, moderation effects were studied from samples containing different hydrogen concentrations. The soil samples with different hydrogen concentration were prepared by mixing soil with water as well as benzene in different weight proportions. Then, the effects of increasing water and benzene concentrations on the yields of hydrogen, carbon and silicon prompt gamma rays were measured. Moderation effects are more pronounced in soil samples mixed with water as compared to those from soil samples mixed with benzene. This is due to the fact that benzene contaminated soil samples have about 30% less hydrogen concentration by weight than the water contaminated soil samples. Results of the study will be presented. (authors)

  5. Power distribution system reliability evaluation using dagger-sampling Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Y.; Zhao, S.; Ma, Y. [North China Electric Power Univ., Hebei (China). Dept. of Electrical Engineering

    2009-03-11

    A dagger-sampling Monte Carlo simulation method was used to evaluate power distribution system reliability. The dagger-sampling technique was used to record the failure of a component as an incident and to determine its occurrence probability by generating incident samples using random numbers. The dagger sampling technique was combined with the direct sequential Monte Carlo method to calculate average values of load point indices and system indices. Results of the 2 methods with simulation times of up to 100,000 years were then compared. The comparative evaluation showed that less computing time was required using the dagger-sampling technique due to its higher convergence speed. When simulation times were 1000 years, the dagger-sampling method required 0.05 seconds to accomplish an evaluation, while the direct method required 0.27 seconds. 12 refs., 3 tabs., 4 figs.

  6. Two sampling techniques for game meat

    OpenAIRE

    van der Merwe, Maretha; Jooste, Piet J.; Hoffman, Louw C.; Calitz, Frikkie J.

    2013-01-01

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling...

  7. Vapor space characterization of waste Tank 241-TX-118 (in situ): Results from samples collected on 9/7/94

    International Nuclear Information System (INIS)

    Thomas, B.L.; Clauss, T.W.; Ligotke, M.W.; Pool, K.H.; McVeety, B.D.; Olsen, K.B.; Fruchter, J.S.; Goheen, S.C.

    1995-10-01

    This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-TX-118 (referred to as Tank TX-118). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH 3 ), nitrogen dioxide (NO 2 ), nitric oxide (NO), hydrogen cyanide (CHN), and water (H 2 O). Sampling for sulfur oxides (SO x ) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 13 analytes. Hexane, normally included in the additional analytes, was removed because a calibration standard was not available during analysis of Tank TX-118 SUMMA trademark canisters. Of these, 12 were observed above the 5-ppbv reporting cutoff. Fourteen tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 86% of the total organic components in Tank TX-118. Permanent gas analysis was not conducted on the tank-headspace samples. Tank TX-118 is on both the Ferrocyanide and Organic Watch List

  8. Headspace vapor characterization of Hanford Waste Tank SX-102: Results from samples collected on July 19, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    McVeety, B.D.; Evans, J.C.; Clauss, T.W.; Pool, K.H.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-102 (Tank SX-102) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed under the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5046. Samples were collected by WHC on July 19, 1995, using the vapor sampling system (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  9. Headspace vapor characterization of Hanford Waste Tank AX-103: Results from samples collected on June 21, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Ligotke, M.W.; Pool, K.H.; Clauss, T.W.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-103 (Tank AX-103) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5029. Samples were collected by WHC on June 21, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  10. Headspace vapor characterization of Hanford Waste Tank AX-101: Results from samples collected on June 15, 1995. Tank Vapor Characterization Project

    International Nuclear Information System (INIS)

    Pool, K.H.; Clauss, T.W.; Evans, J.C.; McVeety, B.D.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-101 (Tank AX-101) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) under the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5028. Samples were collected by WHC on June 15, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace

  11. Non-uniform sampling of NMR relaxation data

    DEFF Research Database (Denmark)

    Schwarz-Linnet, Troels; Teilum, Kaare

    2016-01-01

    The use of non-uniform sampling of NMR spectra may give significant reductions in the data acquisition time. For quantitative experiments such as the measurement of spin relaxation rates, non-uniform sampling is however not widely used as inaccuracies in peak intensities may lead to errors...... in the extracted dynamic parameters. By systematic reducing the coverage of the Nyquist grid of (15)N Carr-Purcell-Meiboom-Gill (CPMG) relaxation dispersion datasets for four different proteins and performing a full data analysis of the resulting non-uniform sampled datasets, we have compared the performance...... of the multi-dimensional decomposition and iterative re-weighted least-squares algorithms in reconstructing spectra with accurate peak intensities. As long as a single fully sampled spectrum is included in a series of otherwise non-uniform sampled two-dimensional spectra, multi-dimensional decomposition...

  12. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

    Science.gov (United States)

    Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A

    2014-03-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method. Published by Elsevier B.V.

  13. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods

    Science.gov (United States)

    Coes, Alissa L.; Paretti, Nicholas V.; Foreman, William T.; Iverson, Jana L.; Alvarez, David A.

    2014-01-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19–23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.

  14. The Portuguese adaptation of the Gudjonsson Suggestibility Scale (GSS1) in a sample of inmates.

    Science.gov (United States)

    Pires, Rute; Silva, Danilo R; Ferreira, Ana Sousa

    2014-01-01

    This paper comprises two studies which address the validity of the Portuguese adaptation of the Gudjonsson Suggestibility Scale, GSS1. In study 1, the means and standard deviations for the suggestibility results of a sample of Portuguese inmates (N=40, Mage=37.5 years, SD=8.1) were compared to those of a sample of Icelandic inmates (Gudjonsson, 1997; Gudjonsson & Sigurdsson, 1996). Portuguese inmates' results were in line with the original results. In study 2, the means and standard deviations for the suggestibility results of the sample of Portuguese inmates were compared to those of a general Portuguese population sample (N=57, Mage=36.1 years, SD=12.7). The forensic sample obtained significantly higher scores in suggestibility measures than the general population sample. ANOVA confirmed that the increased suggestibility in the inmates sample was due to the limited memory capacity of this latter group. Given that the results of both studies 1 and 2 are in keeping with the author's original results (Gudjonsson, 1997), this may be regarded as a confirmation of the validity of the Portuguese GSS1. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Vapor space characterization of waste tank 241-C-101: Results from samples collected on 9/1/94

    International Nuclear Information System (INIS)

    Lucke, R.B.; Clauss, T.W.; Ligotke, M.W.

    1995-11-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-101 (referred to as Tank C-101) and the ambient air collected - 30 ft upwind near the tank and through the VSS near the tank. Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The sample job was designated S4056, and samples were collected by WHC on September 1, 1994, using the vapor sampling system (VSS). The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL record book 55408 before implementation of PNL Technical Procedure PNL-TVP-07. Custody of the sorbent traps was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated (≤ 10 degrees C) temperature until the time of analysis. The canisters were stored in the 326/23B laboratory at ambient (25 degrees C) temperature until the time of the analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions (for NH 3 , NO 2 , and NO analyses). The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS)

  16. Comparison between two sampling methods by results obtained using petrographic techniques, specially developed for minerals of the Itataia uranium phosphate deposit, Ceara, Brazil

    International Nuclear Information System (INIS)

    Salas, H.T.; Murta, R.L.L.

    1985-01-01

    The results of comparison of two sampling methods applied to a gallery of the uranium-phosphate ore body of Itataia-Ceara State, Brazil, along 235 metres of mineralized zone, are presented. The results were obtained through petrographic techniques especially developed and applied to both samplings. In the first one it was studied hand samples from a systematically sampling made at intervals of 2 metres. After that, the estimated mineralogical composition studies were carried out. Some petrogenetic observations were for the first time verified. The second sampling was made at intervals of 20 metres and 570 tons of ore extracted and distributed in sections and a sample representing each section was studied after crushing at -65. Their mineralogy were quantified and the degree of liberation of apatite calculated. Based on the mineralogical data obtained it was possible to represent both samplings and to make the comparison of the main mineralogical groups (phosphates, carbonates and silicates). In spite of utilizing different methods and methodology and the kind of mineralization, stockwork, being quite irregular, the results were satisfactory. (Author) [pt

  17. Performance of the Lot Quality Assurance Sampling Method Compared to Surveillance for Identifying Inadequately-performing Areas in Matlab, Bangladesh

    OpenAIRE

    Bhuiya, Abbas; Hanifi, S.M.A.; Roy, Nikhil; Streatfield, P. Kim

    2007-01-01

    This paper compared the performance of the lot quality assurance sampling (LQAS) method in identifying inadequately-performing health work-areas with that of using health and demographic surveillance system (HDSS) data and examined the feasibility of applying the method by field-level programme supervisors. The study was carried out in Matlab, the field site of ICDDR,B, where a HDSS has been in place for over 30 years. The LQAS method was applied in 57 work-areas of community health workers i...

  18. Thermal transfer and apparent-dose distributions in poorly bleached mortar samples: results from single grains and small aliquots of quartz

    International Nuclear Information System (INIS)

    Jain, M.; Thomsen, K.J.; Boetter-Jensen, L.; Urray, A.S.

    2004-01-01

    In the assessment of doses received from a nuclear accident, considerable attention has been paid to retrospective dosimetry using the optically stimulated luminescence (OSL) of heated materials such as bricks and tiles. quartz extracted from these artefacts was heated during manufacture; this process releases all the prior trapped charge and simultaneously sensitises he quartz. Unfortunately unheated materials such as mortar and concrete are ore common in industrial sites and particularly in nuclear installations. These materials are usually exposed to daylight during quarrying and construction, but in general this exposure is insufficient to completely empty (bleach) any geological trapped charge. This leads to a distribution of apparent doses in the sample at the time of construction with only some (if ny) grains exposed to sufficient light to be considered well bleached for SL dosimetry. The challenge in using such materials as retrospective dosemeters is in identifying these well-bleached grains when an accident dose as been superimposed on the original dose distribution. We investigate here, sing OSL, the background dose in three different mortar samples: render, whitewash and inner wall plaster from a building built in 1964. These samples re found to be both poorly bleached and weakly sensitive (only 0.3% of rains giving a detectable dose response). We study thermal transfer in ingle grains of quartz, investigate the grain-size dependence of bleaching n the size range 90-300 μm and compare the dose-distributions obtained rom small aliquots and single-grain procedures. A comparison of three different methods viz. (a) first 5%, (b) probability plot and (c) comparison f internal and external uncertainties, is made for equivalent dose estimation. The results have implications for accident dosimetry, archaeological studies and dating of poorly bleached sediments

  19. Comparative Study of Wheatley’s Trichrome Stain and In-vitro Culture against PCR Assay for the Diagnosis of Blastocystis sp. in Stool Samples

    Directory of Open Access Journals (Sweden)

    Nabilah Amelia MOHAMMAD

    2018-03-01

    Full Text Available Background: This study evaluated the performance of routine permanent stain and cultivation method in comparison with polymerase chain reaction assay as the reference technique to detect Blastocystis sp.Methods: A cross-sectional study was conducted among aboriginal populations that reside in Pahang, Peninsular Malaysia in Feb to Mar 2015. A total of 359 stool samples were examined using Wheatley’s trichrome stain, in-vitro cultivation in Jones’ medium and PCR assay. Positive amplicons were subjected to sequencing and phylogenetic analysis.Results: Fifty-six (15.6% samples were detected positive with Blastocystis sp. by Wheatley’s trichrome stain and 73 (20.3% by in-vitro culture, while PCR assay detected 71 (19.8% positive samples. Detection rate of Blastocystis sp. was highest in combination of microscopic techniques (27.9%. The sensitivity and specificity of Wheatley’s trichrome staining and in-vitro culture techniques compared to PCR assay were 49.3% (95% CI: 37.2-61.4 and 92.7% (95% CI: 89.1-95.4 and 39.4% (95% CI: 28.0-51.8 and 84.4% (95% CI: 79.7-88.4, respectively. However, the sensitivity [60.6% (95% CI: 48.3-71.9] of the method increased when both microscopic techniques were performed together. False negative results produced by microscopic techniques were associated with subtype 3. The agreement between Wheatley’s trichrome stain, in-vitro culture and combination of microscopic techniques with PCR assay were statistically significant by Kappa statistics (Wheatley’s trichrome stain: K = 0.456, P<0.001; in-vitro culture: K = 0.236, P<0.001 and combination techniques: K = 0.353, P<0.001.Conclusion: The combination of microscopic technique is highly recommended to be used as a screening method for the diagnosis of Blastocystis infection either for clinical or epidemiological study to ensure better and accurate diagnosis.

  20. Comparative Analysis of Different Measurement Techniques for MLC Characterization: Preliminary Results

    International Nuclear Information System (INIS)

    Larraga-Gutierrez, J. M.; Ballesteros-Zebadua, P.; Garcia-Garduno, O. A.; Martinez-Davalos, A.; Rodriguez-Villafuerte, M.; Moreno-Jimenez, S.; Celis, M. A.

    2008-01-01

    Radiation transmission, leakage and beam penumbra are essential dosimetric parameters related to the commissioning of a multileaf collimation system. This work shows a comparative analysis of commonly used film detectors: X-OMAT V2 and EDR2 radiographic films, and GafChromic EBT registered radiochromic film. The results show that X-OMAT over-estimates radiation leakage and 80-20% beam penumbra. However, according to the reference values reported by the manufacturer for these dosimetric parameters, all three films are adequate for MLC dosimetric characterization, but special care must be taken when X-OMAT V2 film is used due to its low energy photon dependence