WorldWideScience
3

Radioiodide uptake in brain, CSF, thyroid, and salivary glands of audiogenic seizure mice  

Energy Technology Data Exchange (ETDEWEB)

DBA/2J (DBA) mice are susceptible to audiogenic seizures (ASs) in an age-dependent manner. Anion transport as measured by radioiodide uptake was determined in thyroid gland, salivary gland, skeletal muscle, cerebral cortex, cerebellum, brainstem, and CSF from these mice at various ages. Anion transport was also determined in C57BL/6J(C57) mice, an AS-resistant strain. In thyroid, DBA mice had an enhanced ability to concentrate iodide at 21 days of age when they have maximal AS susceptibility, as compared with the same-aged C57 mice. This difference in thyroid function was less marked at 40 days of age, when DBA mice are less AS susceptible, and was absent at 110 days of age, when DBA mice are AS resistant. In brain, differences in iodide uptake were also noted between these two strains of mice at 21 days of age. DBA mice had an increased concentration of iodide in CSF, an indication that they have a defect in the transport of iodide out of the ...

1984-08-01

4

Cerebral and meningeal manifestations of AIDS: Sensitivity of CT and T sub 2 -weighted MR (129 patients). Zerebrale und meningeale Manifestation des AIDS: Sensitivitaet von CT und T sub 2 -gewichteter MRT (129 Patienten)  

Energy Technology Data Exchange (ETDEWEB)

We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).

1990-09-01

5

Salivary cortisol assessment in the evaluation of hypothalamic-pituitary-adrenal function  

International Nuclear Information System (INIS)

A simple, short and sensitive direct radio-immunoassay technique for the determination of salivary cortisol concentration was employed to assess saliva as a medium for evaluating cortisol response during endocrine testing in 9 controls and 40 patients. Results in controls suggested that an adequate salivary cortisol response to insulin hypoglycaemia was an increase of 150% above the basal value with a minimum peak of 15 nmol/l. Thirty-three patients were classified as being either good or poor responders to insulin hypoglycaemia on the basis of criteria for plasma cortisol levels. When the defined salivary cortisol response was used for assessment, all 33 patients were correctly categorized into the same response groups. The salivary cortisol response to intramuscular tetracosactin in 3 patients and an intravenous dexamethasone infusion in 4 patients confirmed the value of saliva as an assay medium. ...

1984-05-01

6

Salivary cotinine concentrations in daily smokers in Barcelona, Spain: a cross-sectional study  

UK PubMed Central (United Kingdom)

BackgroundCharacterizing and comparing the determinant of cotinine concentrations in different populations should facilitate a better understanding of smoking patterns and addiction....Full Text Available

7

Necrotizing sialometaplasia of tongue  

UK PubMed Central (United Kingdom)

Necrotizing sialometaplasia, is a benign inflammatory lesion primarily involving the minor salivary glands of the hard palate. The lesion often presents itself as a deep-seated palatal ulcer with clinical...Full Text Available

2009-01-01

8

Serum and salivary responses to oral tetravalent reassortant rotavirus vaccine in newborns.  

UK PubMed Central (United Kingdom)

Serum and salivary responses of 95 infants to either a standard (4 x 10(4) plaque-forming units (PFU), 47 neonates) or a high dose (4 x 10(5) PFU, 48 neonates) of tetravalent reassortant rhesus rotavirus...Full Text Available

1993-05-01

9

Evaluation of the radioprotective effect of turmeric extract and vitamin E in mice exposed to therapeutic dose of radioiodine  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the radioprotective effect of turmeric extract (40 mg/kg body weight) and vitamin E (#alpha# - tocopherol acetate, 400 IU/kg body weight) supplementation on lipid peroxidation, reduced glutathione and antioxidant defense enzymes in various organs like liver, kidney and salivary glands at 24 h in adult Swiss mice. "1"3"1Iodine exposure significantly increased lipid peroxidation in kidney and salivary glands in comparison to control animals. Pre supplementation with turmeric extract for 15 days showed significant lowering of lipid peroxidation in kidney. On the other hand vitamin E pre supplementation showed marked reduction in lipid peroxidation in salivary glands. Reduced glutathione levels decreased significantly in liver after radiation exposure. However, pre supplementation with turmeric extract and vitamin E did not improve glutathione levels in liver. In conclusion we have observed ...

2008-10-01

10

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

11

Genome-Wide Analysis Reveals a Major Role in Cell Fate Maintenance and an Unexpected Role in Endoreduplication for the Drosophila FoxA Gene Fork Head  

UK PubMed Central (United Kingdom)

Transcription factors drive organogenesis, from the initiation of cell fate decisions to the maintenance and implementation of these decisions. The Drosophila embryonic salivary gland...Full Text Available

12

Candidate salivary biomarkers associated with alveolar bone loss: cross-sectional and in vitro studies  

UK PubMed Central (United Kingdom)

This cross-sectional study evaluated the association between radiographic evidence of alveolar bone loss and the concentration of host-derived bone resorptive factors (interleukin-1 beta, tumor...Full Text Available

2007-03-01

13

An unusual presentation of adenoid cystic carcinoma of the minor salivary glands with cranial nerve palsy: a case study  

UK PubMed Central (United Kingdom)

BackgroundAdenoid Cystic Carcinoma (ACC) is a rare tumor entity and comprises about 1% of all malignant tumor of the oral and maxillofacial region. It is slow growing but a highly...Full Text Available

14

MR imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma: correlation with surgical and pathologic findings  

International Nuclear Information System (INIS)

The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement in 73% and liver ...

2008-10-01

15

Diagnostic features of intrahepatic cholangiocarcinoma according to the gross type classification  

International Nuclear Information System (INIS)

Forty resected cases of intrahepatic cholangiocarcinoma were classified into four types according to the gross appearance; type I: mass forming type (n=8), type II: mass forming with periductal infiltrating type (n=20), type III: periductal infiltrating type (n=9) and type IV: intraductal growth type (n=3). Diagnostic features of these four types were studied. Peripheral enhancement was a common angiographic feature and tumor stains were recognized in 88%, 20%, 0%, 33%, respectively. Angiography and dynamic computed tomography (D-CT) were useful in differential diagnosis with hepatocellular carcinoma. Accuracy rate in diagnosis of portal vein involvement by angiography and D-CT was 82% and 91%, respectively. MRI was more useful in tumor detection than D-CT in cases with attenuation difference, in 55% of type II and in 75% of type III. Increase of arterial involvement, biliary tract involvement and portal vein involvement, incidence of lymph ...

1998-08-01

16

Visualization of the salivary glands. CT and MRI  

International Nuclear Information System (INIS)

For the evaluation of diseases of salivary origin, ultrasound and/or sialography is recommended instead of MRI. In cases of salivary tumor, ultrasound may be helpful in delineating superficial tumors. For small tumors no further imaging is needed. When dealing with a large tumor or a tumor in the deep lobe of the parotid gland, MRI is the preferred imaging method. Not only does MRI provide a large variety of soft tissue signal differences, but also the multiplanar facilities are helpful in delineating the extent of the tumor, whether located in the submandibular, sublingual, or parotid gland. Skull base invasion is often well seen by MRI. Subtle changes may be missed and in those cases CT is recommended to exclude or prove destruction of the skull base. For the evaluation of patients presenting with a recurrent pleomorphic adenoma, MRI is recommended in all patients. MRI delineates the extent and number of recurrent tumors better than palpation ...

17

Chemical Reactor Diagnostics  

International Science & Technology Center (ISTC)

Development of Methods and Apparatus for Processes Diagnostics in Plasma Reactors at the Neutralization of Chemical Herbiside and Pestiside

18

Beam Diagnostic System for High Intensity Proton Linac at KAERI  

CERN Document Server

Beam Diagnostic System for High Intensity Proton Linac at KAERI

2003-01-01

19

On the development of a laser detonator  

Science.gov (United States)

The initiation of explosives by laser illumination has been known for many years. In this paper we will discuss the development of a working detonator design that reduces the energy required for detonation in a low-density secondary explosive by vaporizing a thin metal coating. We present data on the development of the design for a workhorse laser detonator that provides enhanced safety over existing exploding bridgewire detonators (EBWs). Comparison of this laser initiated data to an exploding-bridgewire (EBW) provides insight into the mechanism of initiation of detonation in low-density PETN by the plasma source. A novel diagnostic technique to determine the run-distance to detonation also known as the apparent Center-of-Initiation (COI) will also be discussed.

2005-09-01

20

Diagnostic value of MRI for hepatic hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To investigate the value of MRI in the diagnosis of hepatic hilar cholangiocarcinoma. Methods: Sixty-four patients with hepatic hilar cholangiocarcinomas confirmed by surgery or pathology underwent MRI using a 1.5-T superconductive MR system including conventional unenhanced MRI, MRCP and dynamic contrast-enhanced MRI with Gd-DTPA. Results: Dilatation of the intrahepatic biliary tree with narrowing, occlusion or filling defects in the hepatic hilar bile ducts was noted in all 64 cases. Unenhanced MR[ showed T_1- and T_2-hyperintense hilar masses in 42 patients and was normal in the remaining 22 patients. The hilar masses demonstrated slow, progressive and delayed enhancement patterns. There was enhancement of the thickened bile duct wall with luminal narrowing in the 22 patients without hilar masses. Conclusion: The characteristic MRI findings of enhancing hepatic hilar mass and bile duct ...

2010-02-01

21

The normal developmental regulation of a cloned sgs3 'glue' gene chromosomally integrated in Drosophila melanogaster by P element transformation.  

UK PubMed Central (United Kingdom)

A 7-kb genomic segment containing the coding sequence for the Drosophila melanogaster Formosa variant of salivary gland secretion protein 3 (sgs3) has been inserted into the snw y, bw, st strain of...Full Text Available

1983-01-01

22

Molecular Characterization of a Haemaphysalis longicornis Tick Salivary Gland-Associated 29-Kilodalton Protein and Its Effect as a Vaccine against Tick Infestation in Rabbits  

UK PubMed Central (United Kingdom)

The use of tick vaccines in mammalian hosts has been shown to be the most promising alternative tick control method to current use of acaricides, which suffers from a number of limitations. However,...Full Text Available

1999-04-01

23

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

24

High-End CT for clinical and scientific applications; High-End-CT im klinischen und wissenschaftlichen Einsatz  

Energy Technology Data Exchange (ETDEWEB)

The enhancements described of high-performance CT systems of latest design have again confirmed the importance of CT systems for acute and selective diagnostic imaging. Higher availability, shorter exposure times, and better applicability and handling for examination of poly-traumata patients or patients of intensive care departments are some of the advantages achieved with CT systems which demonstrate CT system efficiency in addition to MRI, which for specific examinations will remain the modality of first choice for diagnostic evaluation. The Tomoscan Av-E presented here was able to answer all relevant diagnostic questions appearing in routine diagnostics and scientific work. For patients, examinations using the spiral CT technique also offers significant advantages. (orig./CB) [Deutsch] Durch die dargestellten Verbesserungen bei Hochleistungs-CT-Systemen neuester Bauart wurde die ...

1997-12-01

25

Clinical MR mammography. Impact of hormonal status on background enhancement and diagnostic accuracy  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Hormonal stimulation can induce background enhancement (BE) in MR mammography (MRM). This fact has been assumed to decrease the accuracy of MRM. Consequently, this report investigates: 1. The prevalence of BE in postmenopausal vs. premenopausal women in correlation to hormonal cycle phase (CP). 2. The impact of hormonal status (HS) and BE on diagnostic accuracy. Materials and Methods: Consecutive patients over 22 months with complete HS information (week of CP or postmenopausal) were included in this prospective investigation. Exclusion criteria were any hormonal therapy, hysterectomy as well as cancer proven by biopsy. The standard of reference was histopathology. All MRM scans were acquired using the same protocol (1.5 T, dynamic T 1w GRE after 0.1 mmol/kg bw Gd-DTPA i. v.). Two radiologists rated all examinations in consensus according to BI-RADS. BE was defined as: 0 = missing, 1 = moderate, 2 = distinct. Results: 224 patients (150 ...

2011-05-15

26

Ultrasonography and Computerized Tomography in the diagnosis of complex abdominal lesions  

International Nuclear Information System (INIS)

Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections and, less frequently, cystic tumors; class IV includes 9 cases in ...

1988-01-01

27

Regulatory requirements for design of safety related computer based control Systems in Indian PHWRs: case study of DPHS-PCS for TAPP-3 and 4  

International Nuclear Information System (INIS)

Computer based control systems for safety related applications in nuclear power plants have to meet not only the functional, performance and interface requirements, they in addition, have to meet regulatory requirements like enhanced reliability, safety and security and should provide fault tolerance, diagnostics and self-supervision. The control system architecture, hardware design and software design should meet requirements as specified in design code and guides of AERB. The Dual Processor Hot Standby Process Control System (DPHS-PCS) for TAPP-3 and 4 is a safety related (Class- IB) system. DPHS-PCS regulates PHT pressure, Pressuriser pressure, Pressuriser level, Bleed condenser pressure, Bleed condenser level and Steam generator pressure. The performance, reliability and safety requirements of this control system are met by employing a fault tolerant computer configuration developed for this purpose using hardware designed with facility for ...

2005-03-01

28

A marvel of colors and ingredients. The story of urine test strip.  

Science.gov (United States)

The history of the urinary test papers does not being in the post-war period. As early as the 1880's some practitioners and pharmacists tried to replace the complicated wet-chemical procedures and apparatus by "dry chemistry." The first popular test paper for sugar and albumin originated in England in 1883. Dry reagents for proving hematuria have been available since the beginning of this century. Until the 1930s a wide palette of commercial urine tests with "modern" brand names was established. A methodological breakthrough was created by the spot test chemistry inaugurated by the Austrian, Fritz Feigl, about 1920. Using the capillary properties of filter paper in enhancing color reactions he founded a new area of analytical chemistry. Many of the pioneers were recruited from Jewish scientists. In this lecture is proposed that their emigration and banishment as well as the Second World War have stopped the development of urinary diagnostics on ...

1994-11-01

30

Modern Optical Diagnostics for Technical Combustion Research  

ScienceCinema

...different sparking language english ? ...

32

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

33

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease  

International Nuclear Information System (INIS)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 hemangioma, 1 regenerative nodule) all ...

2000-03-01

34

Solute carrier transporters as targets for drug delivery and pharmacological intervention for chemotherapy  

British Library Electronic Table of Contents (United Kingdom)

Abstract Many solute carrier transporters that interact with anticancer agents and contribute to their pharmacokinetics have been shown to be differentially upregulated in cancer cells as a result of adaptive response to altered nutritional requirements. This review focuses on pathophysiological function of membrane transporters responsible for the influx of physiological substances including oligopeptides, amino acids, and organic cations and anions, and summarizes the recent knowledge regarding mechanisms in their gene expressions. Broad substrate specificity of enhanced oligopeptide H+/peptide cotransporter 1 activity in cancer cells is useful for tumor tissue-specific delivery of chemotherapeutic agents and positron emission tomography diagnostic probes. Amino acid transporters such as...

2011-01-01

35

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

36

Detection of Microcalcification in Mammograms Using Wavelet Transform and Fuzzy Shell Clustering  

CERN Document Server

Microcalcifications in mammogram have been mainly targeted as a reliable earliest sign of breast cancer and their early detection is vital to improve its prognosis. Since their size is very small and may be easily overlooked by the examining radiologist, computer-based detection output can assist the radiologist to improve the diagnostic accuracy. In this paper, we have proposed an algorithm for detecting microcalcification in mammogram. The proposed microcalcification detection algorithm involves mammogram quality enhancement using multirresolution analysis based on the dyadic wavelet transform and microcalcification detection by fuzzy shell clustering. It may be possible to detect nodular components such as microcalcification accurately by introducing shape information. The effectiveness of the proposed algorithm for microcalcification detection is confirmed by experimental results.

2010-01-01

37

Condition monitoring and optimization of a 340 MW re-powered combined cycle plant. Part 1: Design  

Energy Technology Data Exchange (ETDEWEB)

This paper focuses on the application and features of a unified multi-machine train condition monitoring and diagnostic system as applied to a 340 MW repowered combined cycle power plant. Modifications during repowering of the plant required the addition of gas turbines, and design changes to the boiler and steam turbine. Operational procedure during startup also had to be developed. In order to improve the economics of operation, enhancement of both plant operational efficiency and availability were required. Thus it was decided to implement an on-line plant-wide multi-machine Condition Monitoring System. In this paper, the details of the condition monitoring system and some of the design details of the power plant are presented. Requirements of a condition monitoring system applicable to a combined cycle plant are also covered. Salient system design features are explained. The system has been implemented in a combined cycle plant at Bergum, ...

1994-12-31

38

Antihemostatic molecules from saliva of blood-feeding arthropods.  

Science.gov (United States)

The ability to feed on vertebrate blood has evolved many times in various arthropod clades. Each time this trait evolves, novel solutions to the problem posed by vertebrate hemostasis are generated. Consequently, saliva of blood-feeding arthropods has proven to be a rich source of antihemostatic molecules. Vasodilators include nitrophorins (nitric oxide storage and transport heme proteins), a variety of peptides that mimic endogenous vasodilatory neuropeptides, and proteins that catabolize or sequester endogenous vasoconstrictors. A variety of platelet aggregation inhibitors antagonize platelet responses to wound-generated signals, including ADP, thrombin, and collagen. Anticoagulants disrupt elements of both the intrinsic and extrinsic pathways. Molecular approaches (termed 'sialomics') to characterize the full inventory of mRNAs transcribed in salivary glands have revealed a surprising level of complexity within a single species. Multiple ...

2005-01-01

39

Clinical application of dual energy subtraction in direct digital radiography of chest  

International Nuclear Information System (INIS)

Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digital radiography of chest. Methods: 83 cases of chest digital radiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The double energy subtraction (DES) films showed a higher diagnostic accuracy in the ...

2009-02-01

40

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

41

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

42

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...

2000-05-01

43

Neutron detection techniques for plasma diagnostics at the Joint European Torus (JET)  

International Nuclear Information System (INIS)

The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.

44

Proton storage ring (PSR) diagnostics and control system  

Energy Technology Data Exchange (ETDEWEB)

When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system.

1983-01-01

45

The Development of a Dental Diagnostic Terminology  

UK PubMed Central (United Kingdom)

There is no commonly accepted standardized terminology for oral diagnoses. The purpose of this article is to report the development of a standardized dental diagnostic terminology by a work...Full Text Available

2011-01-01

46

Clinical use of lipiodol in hepatic arteriography  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol, lipid soluble contrast media, was applied to 59 patients, who was clinically suspected to have hepatic tumor, in the Department of Diagnostic Radiology, Seoul National University Hospital. The results of the clinical use of Lipiodol were as follows: 1. The clinical diagnosis was hepatocellular carcinoma (HCC) in 50 cases, cavernous hemangioma in 4 cases, metastasis in one case and others in 4 cases. 2. After hepatic arteriography, Lipiodol only was injected in 28 cases, mixture of Lipiodol and Mitomycin was injected in 22 cases and transcatheter arterial embolization was performed additionally after injection of Lipiodol and Mitomycin in 9 cases. 3. Among the 50 cases of HCC, Lipiodol was accumulated in the lesion in 49 cases. However, similar accumulation of Lipiodol occured in a metastatic cancer and cavernous hemangiomas. 4. Plain radiographic patterns of Lipiodol accumulation could be divided into fine granular type, nodular type and linear or ...

1986-08-15

47

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, contrast ...

48

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

International Nuclear Information System (INIS)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were ...

1999-09-01

49

Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo  

Energy Technology Data Exchange (ETDEWEB)

Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in clinical trials. Cellular changes occur during many diseases, thus the molecular imaging ...

2008-12-15

50

Fault detection and diagnosis of an industrial steam turbine using fusion of SVM (support vector machine) and ANFIS (adaptive neuro-fuzzy inference system) classifiers  

Energy Technology Data Exchange (ETDEWEB)

The subject of FDD (fault detection and diagnosis) has gained widespread industrial interest in machine condition monitoring applications. This is mainly due to the potential advantage to be achieved from reduced maintenance costs, improved productivity and increased machine availability. This paper presents a new FDD scheme for condition machinery of an industrial steam turbine using a data fusion methodology. Fusion of a SVM (support vector machine) classifier with an ANFIS (adaptive neuro-fuzzy inference system) classifier, integrated into a common framework, is utilized to enhance the fault detection and diagnostic tasks. For this purpose, a multi-attribute data is fused into aggregated values of a single attribute by OWA (ordered weighted averaging) operators. The simulation studies indicate that the resulting fusion-based scheme outperforms the individual SVM and ANFIS systems to detect and diagnose incipient steam turbine faults. ...

2010-12-15

51

Degree of Mathematics Fluency and Success in Second-Semester Introductory Chemistry  

Science.gov (United States)

We report on the contents and results for 360 students of a mathematics assessment administered at the start of the second-semester introductory chemistry course required for science and engineering majors at the University of Minnesota. This calculator-free, 20-question, 30-minute, multiple-choice, diagnostic quiz includes questions selected specifically for their relevance to this course, concerning logarithms, scientific notation, graphs, and algebra. For the 325 students in degree-granting programs, significant correlations are reported between their mathematics assessment scores and success in this course, as measured by performance on exams (for which scientific calculators were permitted) and course grades. These observations suggest that responses to the simple questions on this unannounced quiz have some predictive utility as signatures of underlying thinking and learning patterns that are associated with success in this course. In addition, we argue that ...

2008-05-01

52

Analysis of complex systems using neural networks  

Energy Technology Data Exchange (ETDEWEB)

The application of neural networks, alone or in conjunction with other advanced technologies (expert systems, fuzzy logic, and/or genetic algorithms), to some of the problems of complex engineering systems has the potential to enhance the safety, reliability, and operability of these systems. Typically, the measured variables from the systems are analog variables that must be sampled and normalized to expected peak values before they are introduced into neural networks. Often data must be processed to put it into a form more acceptable to the neural network (e.g., a fast Fourier transformation of the time-series data to produce a spectral plot of the data). Specific applications described include: (1) Diagnostics: State of the Plant (2) Hybrid System for Transient Identification, (3) Sensor Validation, (4) Plant-Wide Monitoring, (5) Monitoring of Performance and Efficiency, and (6) Analysis of Vibrations. Although specific examples described ...

1992-01-01

53

Analysis of complex systems using neural networks  

Energy Technology Data Exchange (ETDEWEB)

The application of neural networks, alone or in conjunction with other advanced technologies (expert systems, fuzzy logic, and/or genetic algorithms), to some of the problems of complex engineering systems has the potential to enhance the safety, reliability, and operability of these systems. Typically, the measured variables from the systems are analog variables that must be sampled and normalized to expected peak values before they are introduced into neural networks. Often data must be processed to put it into a form more acceptable to the neural network (e.g., a fast Fourier transformation of the time-series data to produce a spectral plot of the data). Specific applications described include: (1) Diagnostics: State of the Plant (2) Hybrid System for Transient Identification, (3) Sensor Validation, (4) Plant-Wide Monitoring, (5) Monitoring of Performance and Efficiency, and (6) Analysis of Vibrations. Although specific examples described ...

1992-12-31

54

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

55

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

59

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

63

CT colonography. Virtual coloscopy; CT-Kolonographie. Virtuelle Koloskopie  

Energy Technology Data Exchange (ETDEWEB)

The CT colonography or virtual coloscopy is a new diagnostic method that allows the presentation of the whole colon using minimal invasive procedures. The method allows the detection of colorectal polyps and colorectal carcinomas. The book includes the following chapters: indications for CT colonography, diagnostic procedures, data processing and interpretation, diagnostic findings, preparation of the diagnostic result description and documentation, screening.

2009-07-01

65

Alternative Technologies for Medical Radionuclide Production  

International Science & Technology Center (ISTC)

Creation of Economic Alternative Technologies for Radionuclide Production for Medical Diagnostics and Therapy

66

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can be used as ...

2003-07-01

67

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease; Einfluss von biphasischer Spiral-CT, nativer und eisenoxidverstaerkter MRT auf Therapie und Therapiekosten bei Patienten mit fokalen Leberlaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 hemangioma, 1 regenerative nodule) all ...

2000-03-01

68

Diagnostics hardening for harsh environment in Laser Megajoule (invited)  

International Nuclear Information System (INIS)

The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection.

2008-10-01

69

Diagnostic quality in hysterosalpingography  

International Nuclear Information System (INIS)

Purpose: To compare the diagnostic quality and adverse events of the water-soluble, non-ionic, iso-osmolar, dimeric contrast media iodixanol and iotrolan in hysterosalpingography (HSG). Material and Methods: One hundred and twenty patients participated in a double-blind randomized parallel-group phase-III study. Questionnaires and patient interviews were used. Diagnostic quality was assessed using a visual analogue scale and the quality in specific regions was rated using a categorical scale. Results: Overall diagnostic quality was equal for the two groups. There was no statistically significant difference between the two groups in diagnostic quality in the specific regions of interest. No differences between the contrast media were found with regard to adverse events. Conclusion: Both contrast media provided images of high diagnostic quality in HSG. (orig.)

1998-11-01

70

National NIF Diagnostic Program Fiscal Year 2002 Second Quarter Report  

Energy Technology Data Exchange (ETDEWEB)

Since October 2001 the development of the facility diagnostics for NIF has been funded by the NIF Director through the National NIF Diagnostic Program (NNDP). The current emphasis of the NNDP is on diagnostics for the early NIF quad scheduled to be available for experiment commissioning in FY03. During the past six months the NNDP has set in place processes for funding diagnostics, developing requirements for diagnostics, design reviews and monthly status reporting. Those processes are described in an interim management plan for diagnostics (''National NIF Diagnostic Program Interim Plan'', NIF-0081315, April 2002) and a draft Program Execution Plan (''Program Execution Plan for the National NlF Diagnostic Program'', NIF-0072083, October 2001) and ...

2002-04-01

71

Validity of Cardiac Markers as Diagnostic and Prognostic Indicators of Complications in Patients undergoing Percutaneous Coronary Intervention  

UK PubMed Central (United Kingdom)

ObjectivesThe aim of this study was to assess the diagnostic and prognostic value of heart-type fatty acid-binding protein (H-FABP) in elective percutaneous coronary intervention...Full Text Available

2010-04-01

72

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

73

SNQ for medical research  

Energy Technology Data Exchange (ETDEWEB)

The planned spallation source can be of considerable significance for biomedical basic research and for clinically relevant diagnostic and therapeutic applications. The following gives a brief description and explanations for its possible use in clinical medicine: I. Treatment of Malignant Tumors II. Production of Isotopes for Biochemical Investigations in Living Organisms for Diagnostic Purposes.

1984-12-01

74

Reduction of anti-malarial consumption after rapid diagnostic tests implementation in Dar es Salaam: a before-after and cluster randomized controlled study  

UK PubMed Central (United Kingdom)

BackgroundPresumptive treatment of all febrile patients with anti-malarials leads to massive over-treatment. The aim was to assess the effect of implementing malaria rapid diagnostic...Full Text Available

75

Perceived association between diagnostic and non-diagnostic cues of women's sexual interest: General Recognition Theory predictors of risk for sexual coercion  

UK PubMed Central (United Kingdom)

Young men's errors in sexual perception have been linked to sexual coercion. The current investigation sought to explicate the perceptual and decisional sources of these social perception errors,...Full Text Available

2010-01-01

76

Factors underlying diagnostic delay in tuberculosis patients in a rural area in Tanzania: a qualitative approach  

UK PubMed Central (United Kingdom)

BackgroundDiagnostic delay in patients with tuberculosis (TB) leads to ongoing TB transmission, higher mortality rates and increased patient and government health expenditure. Qualitative...Full Text Available

2010-12-01

77

Diagnostic comparison of malaria infection in peripheral blood, placental blood and placental biopsies in Cameroonian parturient women  

UK PubMed Central (United Kingdom)

BackgroundIn sub-Saharan Africa, Plasmodium falciparum malaria in pregnancy presents an enormous diagnostic challenge. The epidemiological and clinical relevance...Full Text Available

78

Diagnostic Performance of Computed Tomography Colonography in Symptomatic Patients and in Patients with Increased Risk for Colorectal Disease  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any ...

2006-11-15

79

Biological, Life Course, and Cross-Cultural Studies All point Toward the Value of Dimensional and Developmental Ratings in the Classification of Psychosis  

UK PubMed Central (United Kingdom)

The diagnostic criteria for schizophrenia in the fourth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV1)...Full Text Available

2007-07-01

80

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

81

Age-Stratified Bayesian Analysis To Estimate Sensitivity and Specificity of Four Diagnostic Tests for Detection of Cryptosporidium Oocysts in Neonatal Calves?  

UK PubMed Central (United Kingdom)

There is no gold standard diagnostic test for the detection of bovine cryptosporidiosis. Infection is usually highest in 2-week-old calves, and these calves also excrete high numbers of oocysts. These...Full Text Available

2011-01-01

82

A simple nomogram for sample size for estimating sensitivity and specificity of medical tests  

UK PubMed Central (United Kingdom)

Sensitivity and specificity measure inherent validity of a diagnostic test against a gold standard. Researchers develop new diagnostic methods to reduce the cost, risk, invasiveness, and time. Adequate...Full Text Available

2010-11-01

86

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

87

Investigating Models of Social Development Using a ...  

Science.gov (United States)

... taker', Adaptive Behavior. In submission. Behavioral Disorders: Diagnostic Criteria for Re- Breazeal (Ferrell), C. (1998), A Motivational System for ...

2011-05-13

88

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

89

Control of Phosphorus Transient Enhanced Diffusion using Co-implantation  

CERN Document Server

Control of Phosphorus Transient Enhanced Diffusion using Co-implantation

2006-01-01

90

Radioiodinated peanut lecitin: A potential radiopharmaceutical for immunodetection of carcinoma expressing the T antigen  

International Nuclear Information System (INIS)

The Thomsen-Friedenreich (T) antigen, #betta#-D-Gal-(1->3)-#alpha#-D-GalNAc, is exposed in reactive form on many human adenocarcinomata, but not on corresponding benign tissues. Peanut lectin (PNA) has a strong binding affinity for the T antigen and reportedly binds preferentially to certain malignant tissues. We investigated the potential of radio-labelled PNA as a tumour localising agent in an animal model system using a mouse lymphoma (RI) shown to bind fluorescein-labelled PNA in vitro. The radio-iodinated lectin showed good tumour localisation and rapid blood clearance. Clear images of tumours were obtained, in serial scintigraphic imaging, by 24 and 48 h. No blood background subtraction was necessary. Biodistribution studies revealed tumour to blood ratios in mice were 6:1 (at 24 h) and 17:1 (at 48 h), and tumour to muscle ratios were 34:1 (at 24 h) and 40:1 (at 48 h). Rapid in vivo breakdown of _1_2_5I-PNA led to some localisation of free iodide in the kidneys, stomach, ...

1983-01-01

91

Non-hematological tumors of head and neck region in the pediatric age group in a tertiary care cancer center  

British Library Electronic Table of Contents (United Kingdom)

Purpose To analyze the clinical profile, management and outcome of non-hematological tumors in head and neck region in children less than 18?years of age. Patients and methods Medical records of patients (0?18?years) presenting with non-hematological tumors of head and neck region from 2000 to 2010 were reviewed. Result Out of the 78 patients identified, 50 were males with median age of 14?years (3?months to 18?years). Histologically, 58 out of the 78 patients had malignant tumors and 20 were metastatic at presentation. Common site of tumor origin was noted as thyroid (23/78), salivary glands (21/78) and nasopharynx (13/78). Out of 78 patients, 44 patients were treated by surgery, 26 patients received radiation and 13 patients received chemotherapy, while 9 patients received radio-iodine (...

2011-01-01

92

Chromosome mapping of human CDC25A and CDC25B phosphatases  

Energy Technology Data Exchange (ETDEWEB)

The human CDC25 tyrosine phosphatases trigger activation of CDC2 by removing inhibitory phosphates; thus the genes encoding these phosphatases may be suspected as potential oncogenes due to their role in promoting cell division. To date, three human CDC25 genes have been identified: CDC25A, B, and C. This communication describes the mapping of CDC25A to chromosome 3p21 and CDC25B to chromosome 20p13 by fluorescence in situ hybridization with confirmation by the polymerase chain reaction of hamster-human somatic cell hybrid DNA. 3p21 is near an area frequently involved in karyotypic abnormalities in renal carcinomas, small cell carcinomas of the lung, and benign tumors of the salivary gland. 20p13 does not seem to be a common area for karyotypic alteration in tumors. Mapping of these genes to their chromosomal loci may help identify tumors with abnormal regulation of CDC25 genes due to genomic alterations. 15 refs., 3 figs.

1993-10-01

93

Value of contrast-enhanced MRI of breast after silicone implant; Wertigkeit der Kontrastmittelmagnetresonanztomographie der Mamma bei Wiederaufbau mittels Implantat  

Energy Technology Data Exchange (ETDEWEB)

Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. MRI correctly diagnosed scar tissue in all cases with indeterminate findings. However, due ...

1997-09-01

94

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation ...

2007-05-07

95

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single ...

2003-12-01

96

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour activity was calculated for summed image frames that resulted ...

2008-07-01

97

Clinically silent heterotaxy with polysplenia syndrome and IVC azygous continuation draining to SVC: CT findings. Case report  

International Nuclear Information System (INIS)

Patients with heterotaxy syndrome often have complex cardiac and extracardiac anomalies requiring further detailed diagnostic evaluation. They often present severe cardiac failure early in life. Newer radiological modalities in the form of spiral computed tomography (CT) and three-dimensional reconstruction of spiral CT allow clear definition of the anatomy of these anomalies. A 59-year-old woman was diagnosed with polysplenia and multiple anomalies in an abdominal ultrasonography (US) during a control medical examination due to a trivial dietary mistake. She was then referred to our institution for further examination of these anomalies and an additional thoraco-abdominal computed tomography (CT) examination. The patient was totally asymptomatic at the time of admission. There was no significant past history and no abnormal laboratory data. We performed abdominal, pelvic and thoracic CT examinations using Somatom Siemens Emotion scanner. ...

2007-01-01

98

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density ...

2000-09-01

99

Helical CT of traumatic injuries of the thoracic aorta; Applicazioni della Tomografia Computerizzata spirale nello studio delle lesioni traumatiche dell'aorta toracica  

Energy Technology Data Exchange (ETDEWEB)

Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 ...

2000-09-01

100

Unsolved problems in the diagnosis and surgical treatment of intramedullary tumors  

Energy Technology Data Exchange (ETDEWEB)

Problems and solutions in the diagnosis and operative treatment were clarified by retrospective evaluation of cases of intramedullary tumor in which MRI and surgery had been performed. The subjects were 16 patients (21-75 years old, mean age: 45 years) whose tumor was surgically removed between 1991 and 1998. MRI was performed preoperatively, and T1-weighted images, T2-weighted images, and enhanced images were obtained. Angiography was also performed in some cases. The histological diagnosis based on the MRI findings before surgery were compared with the pathological diagnosis after the operation. In 9/16 cases (56%), the preoperative histological diagnosis based on the MR images was the same as the pathological diagnosis after the operation. In 8 of the 11 cases (73%) whose images showed clear tumor margins and well shaped the tumor, the tumors were completely removed. The concordance rate between the pathological diagnosis during and after the operation was 67%. ...

2001-04-01

101

Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT. Correlation with histopathological findings  

International Nuclear Information System (INIS)

Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 patients. One ...

2008-08-01

102

Multislice spiral CT (MSCT) in pediatric radiology: dose reduction for chest and abdomen examinations  

International Nuclear Information System (INIS)

The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs of the 120 kV protocol can be multiplied ...

2004-07-01

103

Mechanism of r. f. plasma nitriding of Ti-6Al-4V alloy  

Energy Technology Data Exchange (ETDEWEB)

The objective of the current study was the gradual development of the formation of the nitride layer during inductive r.f. plasma nitriding. The study centers on characterization of refined layers and plasma diagnostics in the vicinity of the sample, and raises critical questions of how the layers and interfacial microstructure might affect the near-surface properties. The composition of the plasma near the surface of the sample (plasma layer) was examined by optical emission spectroscopy and mass spectrometry during plasma nitriding and while sputtering the sample after the nitriding process. It was observed that during the nitriding process, the plasma layer contains Ti, NH[sub n] species, N (or/and N[sup +]), H[sub n] species (or/and H[sup +][sub 2]). However, when the nitrided sample was exposed to argon plasma, Ti, Al and NH were observed. It was found that two distinct sublayers, comprising [delta]-TiN and [delta]-TiN + [epsilon]-Ti[sub 2]N phases, were ...

1993-08-15

104

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

Energy Technology Data Exchange (ETDEWEB)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were ...

1999-09-01

105

Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children  

Energy Technology Data Exchange (ETDEWEB)

Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other sequences. In the other cases, the TIRM signal was diagnostically equivalent. On the TIRM ...

1998-11-01

106

Ganglioneuromas in childhood: MRI and CT characteristics; Ganglioneurome im Kindesalter: CT- und MRT-Charakteristika  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub 1}-weighted scans the ...

2000-05-01

110

Radiation hardening problems of diagnostic components for International Thermonuclear Experimental Reactor (ITER)  

International Nuclear Information System (INIS)

The Joint Work Session of the ITER CDA (Conceptual Design Activities) by four parties, (eg. Japan, USA, USSR and EC), which has continued during 3 years from May 1988 to December 1990 was completed successfully. During the CDA, overall diagnostic systems for the next generation machine was performed for the first time and the principal tasks of Diagnostic research and development (R and D) are identified. In this paper, radiation hardening problems, which should be solved for the period 1991 through 1996 of the ITER EDA (Engineering Design Activities), are described. (author).

111

New developments in the surveillance and diagnostics technology for vibration, structure-borne sound and leakage monitoring systems  

International Nuclear Information System (INIS)

Monitoring and diagnostic systems are of main importance for a safe and efficient operation of nuclear power plants. The author describes new developments with respect to vibration monitoring with a functional extension in the time domain for den secondary circuit, the development of a local system for the surveillance of rotating machines, the structure-borne sound monitoring with improvement of event analysis, esp. the loose part locating, leakage monitoring with a complete system for humidity measurement, and the development of a common platform for all monitoring and diagnostic systems, that allows an efficient access for comparison and cross references.

112

Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.

2005-06-15

113

A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

114

Multiple-Element Eddy Current Probes for Enhanced ...  

Science.gov (United States)

... Accession Number : ADD335251. Title : Multiple-Element Eddy Current Probes for Enhanced Inspection,. Corporate Author : ...

1993-07-01

115

Two-year diagnostic stability in early-onset first-episode psychosis  

British Library Electronic Table of Contents (United Kingdom)

Background:- Only one study has used a prospective method to analyze the diagnostic stability of first psychotic episodes in children and adolescents. The Child and Adolescent First-Episode Psychosis Study (CAFEPS) is a 2-year, prospective longitudinal study of early-onset first episodes of psychosis (EO-FEP). Aim:- To describe diagnostic stability and the variables related to diagnostic changes. Methods:- Participants were 83 patients (aged 9-17-years) with an EO-FEP consecutively attended. They were assessed with a structured interview (Kiddie-Schedule for Affective Disorders and Schizophrenia, Present and Lifetime version) and clinical scales at baseline and after 2-years. Results:- The global consistency for all diagnoses was 63.9%. The small group of bipolar disorder had high stabilit...

2011-01-01

116

Targeting a Ruthenium Complex to the Nucleus with Short Peptides  

UK PubMed Central (United Kingdom)

In an effort to develop octahedral metal complexes as chemotherapeutic and diagnostic agents targeted to DNA, it is critical to optimize the properties of their cellular uptake. Appending d-octaarginine...Full Text Available

2010-05-15

117

Studies on the diagnostic accuracy of lymphography  

International Nuclear Information System (INIS)

Contradictory reports in the literature on the reliability of lymphography stimulated the authors to test the diagnostic accuracy, employing methods which are approximately analogous to practice, using carcinoma of the cervix as the model on which the study was carried out. Using 21 observers it was found that there was no correlation between their experience and on-target accuracy of the diagnosis. Good observers obtained an accuracy of 85% with good proportions between sensitivity in the recognition of detail, specificity and readiness to arrive at a decision on the basis of discriminatory ability. With the help of the concept of the ROC curves, the position taken up by the observers in respect of diagnostic decisions, and a complex manner of assessing the various characteristic factors determining diagnostic accuracy, are demonstrated. This form of test, which permits manipulation of different variants of diagnosis, is ...

118

Reduction of diagnostic expense in space-occupying processes of the pancreas by fine-needle biopsy under computerized tomography (CT)  

International Nuclear Information System (INIS)

Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).

119

Real-Time Diagnostics for a Reusable Rocket Engine - NASA ...  

Science.gov (United States)

of the Intelligent Control System (ICS) for reusable rocket engines. .... the incoming measurements with corresponding estimates, a sensor failure can be ...

120

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

121

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

122

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

123

Pubs.GISS: 1977 Publications  

Science.gov (United States)

Astron. J., 82, 890-901, doi:10.1086/112143. Ghil, M., B. Shkoller, and V. Yangarber, 1977: A balanced diagnostic system compatible with a barotropic prognostic model....

2011-09-17

124

Microscopic-Observation Drug-Susceptibility Assay for the Diagnosis of TB  

UK PubMed Central (United Kingdom)

BACKGROUNDNew diagnostic tools are urgently needed to interrupt the transmission of tuberculosis and multidrug-resistant tuberculosis. Rapid,...Full Text Available

2006-10-12

126

Humoral BMP-2 is Sufficient for Inducing Breast Cancer Microcalcification  

UK PubMed Central (United Kingdom)

Microcalcifications are an important diagnostic marker for breast cancer on mammograms, yet the mechanism of their formation is poorly understood. Indeed, there is presently no short-latency,...Full Text Available

2008-01-01

127

Evaluation of Peripheral Atherosclerosis: A Comparative Analysis of Angiography and Intravascular Ultrasound  

UK PubMed Central (United Kingdom)

ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available

2010-04-01

128

Diagnostics of Radionuclides Effects Results  

International Science & Technology Center (ISTC)

Development of New Methods and Means of Assessing of Consequences of Radionuclide and Heavy Metal Salt Effect, Criteria of Forecasting Physiological State and Productivity of the Farm Animals under Conditions of Ecological Pollution of Environment

129

Diagnostic imaging in pregraduate integrated curricula; Radiologie in einem praegraduellen problembasiert-integrierten Medizincurriculum  

Energy Technology Data Exchange (ETDEWEB)

Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)

2007-11-15

130

Diagnostic Value of C-reactive Protein in Complicated Appendicitis  

UK PubMed Central (United Kingdom)

PurposeEarly detection of appendicitis has increased due to development of computed tomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available

2011-06-01

131

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

132

Cardiac Enzymes, Renal Failure and Renal Transplantation  

UK PubMed Central (United Kingdom)

Diagnostic accuracy of the currently available serum markers of cardiac injury, such as myoglobin, creatine kinase and its myocardial isoform, are altered in patients with renal failure. It is shown...Full Text Available

2006-03-01

133

Anxiety and Cancer Treatment: Response to Stressful Radiotherapy  

UK PubMed Central (United Kingdom)

Previous research with individuals undergoing surgery or diagnostic procedures provided a conceptual framework for analysis of radiation therapy, a common form of cancer treatment. The present...Full Text Available

1984-01-01

134

A Dose- and Time-Controllable Syngeneic Animal Model of Breast Cancer Microcalcification  

UK PubMed Central (United Kingdom)

IntroductionThe development of novel diagnostic agents for the detection of breast cancer microcalcifications requires a reliable animal model. Based on previous...Full Text Available

2010-07-01

135

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before and after iv ...

2002-05-01

136

Trial of using computer tomography in the diagnosis of mediastinal diseases in children  

Energy Technology Data Exchange (ETDEWEB)

In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.

1981-01-01

137

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

138

Spreader Design for FERMI@Elettra Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

In this note we describe a conceptual design of a part ofthe electron beam delivery system for FERMI@Elettra free electron laser(FEL) located between the end of the linac and the entrance to the FEL.This part includes the emittance diagnostic section, the electron beamswitchyard for two FELs called spreader and matching sections. The designmeets various constrains imposed by the existing and planned buildingboundaries, desire for utilization of existing equipment and demands forvarious diagnostic instruments.

2007-01-18

139

Researches on gear fault diagnostic techniques  

Science.gov (United States)

Attention is given to recent research on gear fault diagnostic techniques. A mathematic model for vibration signals of defective gears is presented. Novel methods of gear fault diagnosis, such as zoom complex envelope analysis, wideband demodulation techniques, bispectrum analysis, correlation spectrum analysis, and maximum entropy spectrum analysis, are demonstrated. The wide-band demodulation technique is found to exhibit a high SNR. Bispectrum and correlation spectrum are excellent for some mechanical fault forms.

1992-10-01

140

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

141

Process in Plasma Research at IPJ and IPPLM, POLAND  

International Nuclear Information System (INIS)

The most important results of theoretical and experimental studies of plasmas, which have been achieved at the IPJ in Swierk and IPPLM in Warsaw recently, are presented. Studies of physical phenomena in PF discharges, development of diagnostic techniques and research on new plasma technologies, as performed at IPJ, have been summarized. Studies of dense magnetized plasmas, investigation of physics and applications of laser-produced plasmas; and research on the development of advanced diagnostic techniques for the EUROATOM fusion program, as performed at IPPLM, are also described.

2006-01-01

142

Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.

1996-12-31

143

Evaluation of two-beam spectroscopy as a plasma diagnostic  

Energy Technology Data Exchange (ETDEWEB)

A two-beam spectroscopy (TBS) system is evaluated theoretically and experimentally. This new spectroscopic technique uses correlations between components of emitted light separated by a small difference in angle of propagation. It is thus a non-perturbing plasma diagnostic which is shown to provide local (as opposed to line-of-sight averaged) information about fluctuations in the density of light sources within a plasma - information not obtainable by the usual spectroscopic methods. The present design is an improvement on earlier systems proposed in a thesis by Rostler.

1980-04-01

144

Evaluation of Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay and comparison with cell culture and Syva Chlamydia MicroTrak II EIA in high- and low-risk populations.  

UK PubMed Central (United Kingdom)

Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol...Full Text Available

1995-11-01

145

Electron beam and high-speed optical diagnostics for the Los Alamos HIBAF (High Brightness Accelerator FEL) Facility  

Energy Technology Data Exchange (ETDEWEB)

Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.

1989-01-01

146

Diagnostic imaging of the acutely injured patient  

Energy Technology Data Exchange (ETDEWEB)

This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.

1985-01-01

147

DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators  

Energy Technology Data Exchange (ETDEWEB)

Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.

2005-07-01

148

Computer tomography used in tumour diagnosis in children  

Energy Technology Data Exchange (ETDEWEB)

Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.

1981-01-01

149

Baryon-strangeness correlations: a diagnostic of stronglyinteracting matter  

Energy Technology Data Exchange (ETDEWEB)

The correlation between baryon number and strangeness elucidates the nature of strongly interacting matter. This diagnostic can be extracted theoretically from lattice QCD calculations and experimentally from event-by-event fluctuations. The analysis of present lattice results above the critical temperature severely limits the presence of q{bar q} bound states, thus supporting a picture of independent (quasi)quarks. Details may be found in [1].

2005-10-07

150

Modern visualization of the liver with MRI - current trends and future perspectives; Moderne Leberbildgebung mit der MRT - aktuelle Trends und Zukunft  

Energy Technology Data Exchange (ETDEWEB)

This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T systems, but hitherto irrelevant problems must still be solved. Overall the innovations presented here, applied alone or in combination, facilitate ...

2004-12-01

151

Diagnostic value of apparent diffusion coefficient value in prediction of grade for neuroepithelial tumors  

International Nuclear Information System (INIS)

Objective: To investigate the predictive value of ADC value in grading of neuroepithelial tumors. Methods: The clinical data and images of 70 patients with neuroepithelial tumors pathologically proven were collected and analyzed retrospectively. All the patients were classified into low (WHO I or II) and high (WHO III or IV) grade groups which included 40 and 30 cases respectively according to the 2007 WHO classification of tumours of the central nervous system. All the patients underwent plain and contrast-enhanced MR scan and DWI before surgery. The minimum ADC (MinADC) value was measured postoperatively on ADC maps. The Ki-67 labeling index (Ki-67 LI) of tumor tissue was determined by immunohistochemistry. MinADC values for two groups were analyzed using student t test, while the age and Ki-67 LI for the two groups was analyzed using Mann-Whitney test (P<0.05 considered to be significant). Also the MinADC value and Ki-67 LI were analyzed with Pearson ...

2009-11-01

152

Computed tomography whole body imaging in multi-trauma: 7 years experience  

International Nuclear Information System (INIS)

AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all studies were recorded prospectively. ...

2006-04-01

153

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and ...

1989-02-01

154

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

International Nuclear Information System (INIS)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and ...

1989-01-01

155

CT-guided percutaneous core biopsies of pulmonary lesions: Diagnostic accuracy, complications and therapeutic impact  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were observed in 23 patients (29%). No hemoptysis ...

2001-03-01

156

Metabolic fate of chlorinated paraffins  

Energy Technology Data Exchange (ETDEWEB)

The disposition of three (1-/sup 14/C)-chlorododecanes (MCDD, PCDD I and PCDD II; 17.4%, 55.9%, and 68.5% chlorination) was studied in C57Bl mice. (1-/sup 14/C)-lauric acid (LA) was studied as reference compound. Fifty-two percent (MCDD), 32% (PCDD I), and 8% (PCDD II) of the radioactive doses were exhaled as /sup 14/CO/sub 2/ during 12 h after i.v. injection. Similar results were obtained after p.o. administration. In addition to a marked labelling of the liver and fat, the distribution patterns observed at 24 h after administration revealed an uptake of radioactivity in tissues with high cell turnover/high metabolic activity, e.g., intestinal mucosa, bone marrow, salivary glands and thymus. The concentration of radioactivity in these sites and the exhalation of /sup 14/CO/sub 2/, which were inverse to the degree of chlorination, indicate that the chloroalkanes are degraded to metabolites which can be utilized in the intermediary metabolism. A similar, although ...

1982-09-01

157

Host resistance to rat cytomegalovirus (RCMV) and immune function in adult PVG rats fed herring from the contaminated Baltic Sea  

Energy Technology Data Exchange (ETDEWEB)

We carried out a feeding study in rats aimed at extending our aboservations of contaminant-induced immunosuppression in harbour seals. Two herring batches were freeze-dried, supplemented and fed to female adult PVG rats for a period of 4 1/2 months. Daily contaminant intakes of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) toxic equivalents (TEQ) were estimated to be 0.3 ng/kg body weight and 1.6 ng/kg in the Atlantic and Baltic groups, respectively. At the end of the feeding experiment, no contaminant-related changes in spleen CD{sub 4}{sup +}/CD{sub 8}{sup +} cellularity, natural killer cell activity, or mitogen-induced proliferative responses of thymus or spleen cells could be detected. However, total thymocyte numbers and thymus CD{sub 4}{sup +}/CD{sub 8}{sup +} ratios were reduced in the Baltic group. A novel model was established to assess the specific T-cell response to rat cytomegalovirus (RCMV). When applied to the feeding study, no differences between the Atlantic and Baltic ...

1996-08-01

158

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

159

Diabetes Enhances Periodontal Bone Loss through Enhanced Resorption and Diminished Bone Formation  

UK PubMed Central (United Kingdom)

Using a ligature-induced model in type-2 Zucker diabetic fatty (ZDF) rat and normoglycemic littermates, we investigated whether diabetes primarily affects periodontitis by enhancing bone loss...Full Text Available

2006-06-01

160

Deficiency of Phosphoinositide 3-Kinase Enhancer Protects Mice From Diet-Induced Obesity and Insulin Resistance  

UK PubMed Central (United Kingdom)

OBJECTIVEPhosphoinositide 3-kinase enhancer A (PIKE-A) is a proto-oncogene that promotes tumor growth and transformation by enhancing Akt activity. However, the physiological functions...Full Text Available

2010-04-01

161

The electron cyclotron absorption diagnostic for the JET pumped divertor plasma  

International Nuclear Information System (INIS)

We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may affect the interpretation of the measurement, are also discussed. (orig.).

1993-03-01

162

Mathematical Analysis of Three Free-Electron-Laser Issues  

Science.gov (United States)

... iFfficiency-en- enhanced spontaneous radiation at the free-electron- ... as enhanced spontaneous radiation at the free-electron-laser wavelength. ...

1990-09-30

164

Traumatic extremity arterial injury in children: Epidemiology, diagnostics, treatment and prognostic value of Mangled Extremity Severity Score  

UK PubMed Central (United Kingdom)

BackgroundTraumatic paediatric arterial injuries are a great challenge due to low incidence and specific characteristics of paediatric anatomy and physiology. The aim of the present...Full Text Available

165

The treatment of mycosis fungoides and related conditions with particular emphasis on electron therapy.  

UK PubMed Central (United Kingdom)

The difficulties created by the lack of generally accepted views on classification, diagnostic criteria and natural history of the cutaneous lymphomata are discussed. Only the lymphomata which remain...Full Text Available

1975-03-01

166

The sensitivity of real-time PCR amplification targeting invasive Salmonella serovars in biological specimens  

UK PubMed Central (United Kingdom)

BackgroundPCR amplification for the detection of pathogens in biological material is generally considered a rapid and informative diagnostic technique. Invasive Salmonella...Full Text Available

167

The concept of mental disorder: diagnostic implications of the harmful dysfunction analysis  

UK PubMed Central (United Kingdom)

What do we mean when we say that a mental condition is a medical disorder rather than a normal form of human suffering or a problem in living? The status of psychiatry as a medical discipline depends...Full Text Available

2007-10-01

168

The Effect of Age on the Gingival Crevicular Fluid Composition During Experimental Gingivitis. A Pilot Study  

UK PubMed Central (United Kingdom)

Background:Cytokines have been proposed as potentially useful diagnostic or prognostic markers of periodontal inflammation related alterations during the experimental gingivitis...Full Text Available

169

Stereocomplexed PLA-PEG Nanoparticles with Dual-Emissive Boron Dyes for Tumor Accumulation  

UK PubMed Central (United Kingdom)

Responsive biomaterials play important roles in imaging, diagnostics, and therapeutics. Polymeric nanoparticles (NPs) containing hydrophobic and hydrophilic segments are one class of biomaterial...Full Text Available

2010-09-28

170

Stability of Trichomonas vaginalis DNA in Urine Specimens?  

UK PubMed Central (United Kingdom)

Trichomonas vaginalis is an important pathogen in both men and women. Culture is considered the diagnostic gold standard, although studies have shown that PCR is more sensitive than...Full Text Available

2008-05-01

171

Serum hepcidin as a diagnostic test of iron deficiency in premenopausal female blood donors  

UK PubMed Central (United Kingdom)

BackgroundCurrently used indicators of iron status have limitations. Hepcidin, a key regulator of iron metabolism, is reduced in iron deficiency. We sought to determine the properties...Full Text Available

2011-08-01

172

Rome III: The functional gastrointestinal disorders, third edition, 2006  

UK PubMed Central (United Kingdom)

Functional gastrointestinal disorders (FGIDs) represent a common and important class of disorders within gastroenterology. RomeI, the first edition was published in 1994, with symptom-based diagnostic...Full Text Available

2008-04-07

173

Reduced PCR Sensitivity Due to Impaired DNA Recovery with the MagNA Pure LC Total Nucleic Acid Isolation Kit  

UK PubMed Central (United Kingdom)

The increasing demand for molecular diagnostics in clinical microbiology laboratories necessitates automated sample processing. In the present study, we evaluated the performance of the MagNA Pure LC...Full Text Available

2005-09-01

174

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

175

Pubs.GISS: Ghil et al. 1977: A balanced ... - Publications - NASA  

Science.gov (United States)

Ghil, M., B. Shkoller, and V. Yangarber, 1977: A balanced diagnostic system compatible with a barotropic prognostic model. M. Weather. Rev. , 105, 1223- 1238, ...

176

Prenatal diagnosis for recessive dystrophic epidermolysis bullosa in 10 families by mutation and haplotype analysis in the type VII collagen gene (COL7A1).  

UK PubMed Central (United Kingdom)

BACKGROUND: Epidermolysis bullosa (EB) is a group of heritable diseases that manifest as blistering and erosions of the skin and mucous membranes. In the dystrophic forms of EB (DEB), the diagnostic...Full Text Available

1996-01-01

177

Performance and usefulness of the Hexagon rapid diagnostic test in children with asymptomatic malaria living in the Mount Cameroon region  

UK PubMed Central (United Kingdom)

BackgroundRapid and correct diagnosis of malaria is considered an important strategy in the control of the disease. However, it remains to be determined how well these tests can...Full Text Available

178

PROGRESS AND PROBLEMS IN THE APPLICATION OF FOCUSED ULTRASOUND FOR BLOOD-BRAIN BARRIER DISRUPTION  

UK PubMed Central (United Kingdom)

Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the...Full Text Available

2008-08-01

179

Optical and Structural Characteristics of Heavily Boron-Implanted CdTe.  

Science.gov (United States)

Cadmium telluride single crystals were subjected to multiple-energy boron ion implants with total doses up to 1.5 x 10 sq cm. Various diagnostic techniques were used to assess the structural and electronic properties of these crystals in their as-implante...

1988-01-01

180

Nuclear ? catenin as a potential prognostic and diagnostic marker in patients with colorectal cancer from Hong Kong  

UK PubMed Central (United Kingdom)

Aims: To study the expression of nuclear β catenin in patients with colorectal cancer, colorectal adenoma, and colorectal polyps to elucidate its role in carcinogenesis, and its...Full Text Available

2003-12-01

181

Multiplexed, rapid detection of H5N1 using a PCR-free nanoparticle-based genomic microarray assay  

UK PubMed Central (United Kingdom)

BackgroundFor more than a decade there has been increasing interest in the use of nanotechnology and microarray platforms for diagnostic applications. In this report, we describe...Full Text Available

182

Monitoring potential neurotoxic effects of hazardous waste disposal  

UK PubMed Central (United Kingdom)

This report reviews neurotoxicological principles relevant to situations of hazardous waste disposal. Some of the diagnostic techniques currently used for field assessment of nervous system dysfunction...Full Text Available

1983-02-01

183

Investigation of Dyslexia and SLI Risk Variants in Reading- and Language-Impaired Subjects  

UK PubMed Central (United Kingdom)

Dyslexia (or reading disability) and specific language impairment (or SLI) are common childhood disorders that show considerable co-morbidity and diagnostic overlaps and have been suggested to share...Full Text Available

2011-01-01

184

Impalpable Testis and Laparoscopy: When the Gonad Is Not Visualized  

UK PubMed Central (United Kingdom)

The diagnostic accuracy of laparoscopy for impalpable testis is well recognized. However, in some cases, laparoscopic findings may be misleading, and a viable gonad may be missed with significant medico-legal...Full Text Available

2004-01-01

185

Impact of radiation measurements on hardening of TFTR diagnostics  

International Nuclear Information System (INIS)

Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have substantially overestimated fluxes both inside and outside the TFTR shield walls. It ...

186

Identification of Cardiac Myosin-binding Protein C as a Candidate Biomarker of Myocardial Infarction by Proteomics Analysis*  

UK PubMed Central (United Kingdom)

Acute myocardial infarction (AMI) is a common cause of death for which effective treatments are available provided that diagnosis is rapid. The current diagnostic gold standards are circulating cardiac...Full Text Available

2009-12-01

187

IGENPRO knowledge-based digital system for process transient diagnostics and management  

Energy Technology Data Exchange (ETDEWEB)

Verification and validation issues have been perceived as important factors in the large scale deployment of knowledge-based digital systems for plant transient diagnostics and management. Research and development (R&D) is being performed on the IGENPRO package to resolve knowledge base issues. The IGENPRO approach is to structure the knowledge bases on generic thermal-hydraulic (T-H) first principles and not use the conventional event-basis structure. This allows for generic comprehensive knowledge, relatively small knowledge bases and above all the possibility of T-H system/plant independence. To demonstrate concept feasibility the knowledge structure has been implemented in the diagnostic module PRODIAG. Promising laboratory testing results have been obtained using data from the full scope Braidwood PWR operator training simulator. This knowledge structure is now being implemented in the transient management module PROMANA to treat ...

1997-12-31

188

How Missing Information in Diagnosis Can Lead to Disparities in the Clinical Encounter  

UK PubMed Central (United Kingdom)

Previous studies have documented diagnostic bias and noted that its reduction could eliminate misdiagnosis and improve mental health service delivery. Few studies have investigated clinicians'...Full Text Available

2008-11-01

189

Gonorrhoea in men: clinical and diagnostic aspects.  

UK PubMed Central (United Kingdom)

AIM: To review the features of gonococcal infection in men in the 1990s. METHODS: A retrospective study of all men with gonorrhoea presenting to an inner city department of genitourinary medicine in...Full Text Available

1996-12-01

190

Genetic screening: The vista of genomic medicine  

UK PubMed Central (United Kingdom)

The accelerating development of biochemical and DNA-based diagnostic tests for human genetic conditions in the last decade has engendered a revolution in genetic diagnosis. Both genetic testing and...Full Text Available

2011-01-01

191

Gamuts in nuclear medicine  

Energy Technology Data Exchange (ETDEWEB)

This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.

1983-01-01

192

Fetal, perinatal, and infant death with congenital renal anomaly  

UK PubMed Central (United Kingdom)

Aims: To ascertain why 19.6% of pregnancies in which a fetal renal anomaly has been detected fail to produce a surviving child, and whether antenatal diagnostic accuracy has altered since...Full Text Available

2002-08-01

193

Fetal ascites: an unusual presentation of Niemann-Pick disease type C.  

UK PubMed Central (United Kingdom)

Two infants were seen with severe ascites detected before birth, a previously unreported presentation of Niemann-Pick disease type C. In the second infant no diagnostic storage cells were present in...Full Text Available

1989-10-01

194

Evaluation of the OptiMAL Test for Rapid Diagnosis of Plasmodium vivax and Plasmodium falciparum Malaria  

UK PubMed Central (United Kingdom)

The development of rapid and specific diagnostic tests to identify individuals infected with malaria is of paramount importance in efforts to control the severe public health impact of this disease....Full Text Available

1998-01-01

195

Evaluation of a diagnostic algorithm for heart disease in neonates.  

UK PubMed Central (United Kingdom)

OBJECTIVE--To develop, test, and validate an algorithm for diagnosing disease in neonates during an over the telephone referral to a specialist cardiac centre. DESIGN--A draft algorithm requiring only...Full Text Available

1991-04-20

196

Electrostatic probe vacuum system for TCA BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the technical design and performance of the diagnostic system installed in the tokamak TCABR to measure parameters of the plasma edge. The system consists of four Langmuir probes under remote control. (author)

1999-12-01

197

Diagnostics of Gun Barrel Propellants.  

Science.gov (United States)

Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...

1983-11-01

198

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

199

Diagnostic Dilemma in an Unusual Case of Common Bile Duct Obstruction  

UK PubMed Central (United Kingdom)

Biliary obstructions are rarely caused by a foreign body and have received sparse attention. We present an unusual case with pruritis and abdominal pain caused by impacted full length surgical gauze...Full Text Available

2011-06-01

200

Development and Application of Pathovar-Specific Monoclonal Antibodies That Recognize the Lipopolysaccharide O Antigen and the Type IV Fimbriae of Xanthomonas hyacinthi  

UK PubMed Central (United Kingdom)

The objective of this study was to develop a specific immunological diagnostic assay for yellow disease in hyacinths, using monoclonal antibodies (MAbs). Mice were immunized with a crude cell wall preparation...Full Text Available

1999-09-01

201

Decreased CSF Transferrin in sCJD: A Potential Pre-Mortem Diagnostic Test for Prion Disorders  

UK PubMed Central (United Kingdom)

Sporadic Creutzfeldt-Jakob-disease (sCJD) is a fatal neurodegenerative condition that escapes detection until autopsy. Recently, brain iron dyshomeostasis accompanied by increased transferrin (Tf) was...Full Text Available

202

Cystic neoplasms of the pancreas: A diagnostic challenge  

UK PubMed Central (United Kingdom)

Cystic neoplasms of the pancreas are increasingly recognized due to the expanding use and improved sensitivity of cross-sectional abdominal imaging. Major advances in the last decade have led to an...Full Text Available

2009-01-07

203

Comparing the Diagnostic Performance of 2 Clinical Decision Rules to Rule Out Deep Vein Thrombosis in Primary Care Patients  

UK PubMed Central (United Kingdom)

PURPOSE The Wells rule is widely used for clinical assessment of patients with suspected deep vein thrombosis (DVT), especially in the secondary care setting. Recently a new clinical decision...Full Text Available

2011-01-01

204

Colonic polyps: inheritance, susceptibility, risk evaluation, and diagnostic management  

UK PubMed Central (United Kingdom)

Colorectal cancer (CRC) is the third-ranked neoplasm in order of incidence and mortality, worldwide, and the second cause of cancer death in industrialized countries. One of the most important environmental...Full Text Available

205

Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?  

UK PubMed Central (United Kingdom)

BackgroundThe purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA).MethodsTwenty-three...Full Text Available

206

Clinical efficacy of the use of information technology in cardiology: initial results of angiographic teleconsultation in the Netherlands  

UK PubMed Central (United Kingdom)

Background With the increasing use of cineless diagnostic angiography laboratories, modern telecommunication networks provide an excellent opportunity to transfer dynamic cardiac...Full Text Available

2001-12-01

207

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

208

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of ...

1988-01-01

209

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

210

Blood conservation strategies to reduce the need for red blood cell transfusion in critically ill patients  

UK PubMed Central (United Kingdom)

Anemia commonly affects critically ill patients. The causes are multifactorial and include acute blood loss, blood loss from diagnostic testing and blunted red blood cell production. Blood transfusions...Full Text Available

2008-01-01

211

Bilateral Pneumothorax and Subcutaneous Emphysema following Endoscopic Retrograde Cholangiopancreatography: A Rare Complication  

UK PubMed Central (United Kingdom)

Endoscopic Retrograde Cholangiopancreatography (ERCP) is a widely used diagnostic and therapeutic modality in the management of biliary and pancreatic disease. Some of the complications of the procedure,...Full Text Available

2010-01-01

212

Anti-albumin antibodies in chronic liver diseases: diagnostic significance of these antibodies in patients with conventional or immunosuppressive therapy.  

UK PubMed Central (United Kingdom)

The two categories of anti-albumin antibodies (AAA), namely precipitins (AA-P) and agglutinins (AA-Aggl), were investigated in 260 patients with morphologically diagnosed chronic liver diseases (CLD)....Full Text Available

1981-02-01

213

An evaluation of cerebrospinal fluid oligoclonal banding confirmed by immunofixation on agarose gel.  

UK PubMed Central (United Kingdom)

The cerebrospinal fluid (CSF) from 115 consecutive patients undergoing diagnostic lumbar puncture or myelography was examined to determine the usefulness of immunofixation, following agarose gel electrophoresis,...Full Text Available

1983-06-01

214

Affinity maturation of human botulinum neurotoxin antibodies by light chain shuffling via yeast mating  

UK PubMed Central (United Kingdom)

Botulism is caused by the botulinum neurotoxins (BoNTs), the most poisonous substance known. Because of the high potency of BoNT, development of diagnostic and therapeutic antibodies for botulism requires...Full Text Available

2010-04-01

215

Advances in cancer tissue microarray technology: Towards improved understanding and diagnostics  

UK PubMed Central (United Kingdom)

Over the past few years, tissue microarray (TMA) technology has been established as a standard method for assessing the expression of proteins or genes across large sets of tissue specimens....Full Text Available

2006-03-30

216

Advances in Fine Needle Aspiration Cytology for the Diagnosis of Pulmonary Carcinoma  

UK PubMed Central (United Kingdom)

New developments in the field of thoracic oncology have challenged the way pathologists approach the diagnosis of pulmonary carcinoma. Nonsmall cell carcinoma is no longer an adequate diagnostic category....Full Text Available

217

Accuracy of electrocardiographic and echocardiographic indices in predicting life threatening ventricular arrhythmias in patients operated for tetralogy of Fallot  

UK PubMed Central (United Kingdom)

OBJECTIVE—To validate the accuracy of the prognostic significance of non-invasive clinical diagnostic indices as predictors of sustained ventricular tachycardia (sVT) or fibrillation...Full Text Available

1999-06-01

218

A survey on clinical presentation and nutritional status of infants with suspected cow' milk allergy  

UK PubMed Central (United Kingdom)

BackgroundCow's milk is the most common food allergen in infants and the diagnosis of cow's milk allergy is difficult, even with the use of several diagnostic tests. Therefore, elimination...Full Text Available

219

A diagnostic survey of infants referred for chromosome analysis in the neonatal period.  

UK PubMed Central (United Kingdom)

Examination and assessment of 140 liveborn and stillborn infants referred within two weeks of birth for chromosome analysis showed that 48 had Down's syndrome, 12 other chromosome abnormalities, 17...Full Text Available

1980-10-18

220

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

221

Thomson scattering: a powerful diagnostic tool of plasma physics  

International Nuclear Information System (INIS)

Thomson scattering is the process in which a low-energy photon scatters from a free electron. When a laser pulse propagates through a plasma, the spectrum of the scattered light due to the Thomson scattering is proportional to the power spectrum of the electron density fluctuations, i.e., dynamic form factor, from which various plasma parameters can be inferred, such as electron temperature and plasma flow velocity. After years of development. Thomson scattering has now become a powerful diagnostic tool of plasma physics. (authors)

2008-08-01

222

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

223

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

224

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

225

Radiation risk in diagnostic radiology  

International Nuclear Information System (INIS)

An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).

1984-01-01

226

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

227

Post-transplant monitoring of renal allografts: are we there yet?  

British Library Electronic Table of Contents (United Kingdom)

Transplantation has emerged as the therapy of choice for many patients with end organ failure. One of the major goals is to tailor immunosuppressive therapy to the individual needs of every patient to balance the risk for rejection and over-immunosuppression. This will require diagnostic tools that can detect harmful processes in the allograft early, and that can be measured repeatedly. This review will consider recent advances in our understanding of the molecular nature of these processes and how this information is being utilized to design novel diagnostic assays to non-invasively monitor allografts. Highlighted is the need for large-scale prospective multi-centre studies to validate assays that show early promise in single centre studies.

2009-01-01

228

NuMI proton beam diagnostics and control: achieving 2 megawatt capability  

Energy Technology Data Exchange (ETDEWEB)

The NuMI proton beam at Fermilab currently delivers 120 GeV protons to the neutrino production target with design beam power capability to 400 kW. Upgrade capability to 700 kW is being prepared, with planning toward delivering 2.3 MW beam provided by the Project X accelerator upgrade plan. We report on the system of beam diagnostics and control used in operation of the NuMI beam. Also considered are the steps to provide a robust system for transport and targeting beam of 2 MW and beyond.

2008-10-01

229

GPLS VME MODULE: A DIAGNOSTIC AND DISPLAY TOOL FOR NSLS MICRO SYSTEMS.  

Energy Technology Data Exchange (ETDEWEB)

The General Purpose Light Source VME module is an integral part of every front-end micro in the NSLS control system. The board incorporates features such as a video character generator, clock signals, time-of-day clock, a VME bus interrupter and general-purpose digital inputs and outputs. This module serves as a valuable diagnostic and real-time display tool for the micro development as well as for the final operational systems. This paper describes the functions provided by the board for the NSLS micro control monitor software.

1999-03-29

230

Evaluation of the chest radiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.

1991-12-01

231

Electron temperature diagnostics in the RFX reversed field pinch experiment  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)

2000-08-01

232

Efficient application of medical imaging methods. Graded diagnostics for surgical and internal medical problems. Rationeller Einsatz bildgebender Verfahren. Gestufte Diagnostik bei chirurgischen und internistischen Krankheitsbildern  

Energy Technology Data Exchange (ETDEWEB)

The book is intended as a source of information for general practioners and for medical students doing their practical training. Efficient application of imaging methods is explained with great emphasis on practical aspects, concentrating on typical tasks to be solved for adult patients with internal disease or surgical problems. The material is arranged by various organic systems of the body. Graded diagnostics for a stepwise approach to the final diagnosis is the concept described, and is shown to be of advantage to the patient and in terms of cost and time.

1985-01-01

233

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

234

Performance of Brazilian thermoluminescent CaSO{sub 4}: Dy pellets in standard diagnostic radiology beams  

Energy Technology Data Exchange (ETDEWEB)

The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of different origins in ...

2006-07-01

239

Observations of photon echo enhancement in an ultraslow light regime  

CERN Document Server

Using spectral hole-burning-based ultraslow group velocity in a dilute solid medium, we report enhanced photon echo efficiency three orders of magnitude higher than that in a nonslow light regime. The enhancement is due to exponentially increased absorption of an optical data pulse owing to the enhanced photon-atom interaction in an ultraslow light regime, whereas echo reabsorption is negligibly small due to group-velocity dependent population depletion.

2011-01-01

249

Energy conservation via heat transfer enhancement. Quarterly progress report, October 1-December 31, 1979  

Science.gov (United States)

Contacts with researchers, manufacturers, and users of enhanced heat transfer equipment are summarized. The Technical Literature file and the Patent File continue to be updated; the Patent File is the source for a patent technology report now in draft form. Application studies on a rationally-based friction correlation for internally-finned tubes and on the evaluation of candidate tube-side enhancements for OTEC applications are reported. The technology study on enhancement of spray evaporation is also discussed.

1979-01-01

254

Optimum aspect ratio for heat transfer enhancement in curved rectangular channels  

Science.gov (United States)

Enhanced heat transfer in curved rectangular channels depends on at least two geometric factors, the radius of curvature of the duct and the aspect ratio, which is the width/depth ratio of the duct. In this work, an expression for optimum aspect ratio is derived mathematically from a correlation that includes both aspect ratio and bend curvature parameters. Enhancement factors are developed that show optimal, near-optimal, and nonoptimal aspect ratios for curved rectangular ducts. Predicted enhancements are within 25% of published literature results for individual designs, two of which show heat transfer enhancement of 200% over that of a straight duct with turbulent flow. The theoretical maximum enhancement is shown to be about 480% over a straight-duct, turbulent-flow situation. This is not achievable in practice, but near-optimal solutions are achievable, yielding ...

255

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity; Moderne bildgebende Methoden bei der Diagnostik von Tumoren des Oropharynx und der Mundhoehle  

Energy Technology Data Exchange (ETDEWEB)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, contrast ...

1996-11-01

256

A study of flow boiling phenomena using real time neutron radiography  

International Nuclear Information System (INIS)

The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a cylindrical configuration, and a similar flow channel with an internal ...

1346-01-01

257

Are the delay images necessary to evaIuate the liver metastatic lesions on mangafodipir trisodium enhanced liver MRI?: comparison with hepatocellular carcinomas  

Energy Technology Data Exchange (ETDEWEB)

To assess whether ring enhancements of liver metastases on Mn-DPDP enhanced, early MR images were well visualized on delayed images, as compared with those of hepatocellular carcinomas (HCC), and to investigate the detection accuracy and conspicuity of each tumor. Twenty patients with liver metastases and 15 with HCC were studied by Mn-DPDP enhanced, T1-weighted MR images. Peripheral ring enhancement and conspicuity were investigated. Differences in detection accuracy and frequency of ring enhancement in liver metastases and HCC were assessed. In liver metastases (n= 69), 44 cases (63.8%) without ring enhancement and 25 (36.2%) with were noted on early images. Sixteen cases (23.2%) without ring enhancement, 38 (55.1%) with ring enhancement similar to the early images, and 15 (21.7%) with prominent ring ...

2004-09-01

258

STRUCTURE AND FORMATION OF ELLIPTICAL AND SPHEROIDAL GALAXIES  

International Nuclear Information System (INIS)

New surface photometry of all known elliptical galaxies in the Virgo cluster is combined with published data to derive composite profiles of brightness, ellipticity, position angle, isophote shape, and color over large radius ranges. These provide enough leverage to show that Sersic log I #propor to# r "1"/"n functions fit the brightness profiles I(r) of nearly all ellipticals remarkably well over large dynamic ranges. Therefore, we can confidently identify departures from these profiles that are diagnostic of galaxy formation. Two kinds of departures are seen at small radii. All 10 of our ellipticals with total absolute magnitudes M_V_T #<=# -21.66 have cuspy cores-"missing light"-at small radii. Cores are well known and naturally scoured by binary black holes (BHs) formed in dissipationless ("dry") mergers. All 17 ellipticals with -21.54 #<=# M_V_T #<=# -15.53 do not have cores. We find a new distinct component in these galaxies: all coreless ellipticals ...

2009-05-01

259

Diffusion modeling of ion implanted boron in Si during RTA: Correlation of extended defect formation and annealing with the enhanced diffusion of boron  

International Nuclear Information System (INIS)

Accurate modeling of the enhanced diffusion of boron during rapid thermal annealing has been accomplished by incorporating the effects of extended defect formation and annealing on enhanced diffusion into a multizone, semiempirical model. The multizone model divides the implant profile into three zones defining regions of different defects and diffusion enhancements. The model also contains the initial enhanced diffusion and the transient diffusion effects associated with the dissolution of defect clusters and the annealing of extended defects, respectively. The saturation time for transient-enhanced diffusion contains an exponential function of implant dose in order to model the increase in point defect generated with higher implant dose. As a result, the model accurately simulates the boron diffusion profile over a wide range of implant doses and also shows the immobile boron peak ...

260

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination ...

1981-01-01

261

Diagnostics aid for mass spectrometer trouble-shooting  

International Nuclear Information System (INIS)

The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho General Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to ...

262

The accuracy and reverse effects of thallium myocardial SPECT using adenosine triphosphate loading in the diagnosis of coronary artery disease. Comparison with other loading methods semiquantitatively  

Energy Technology Data Exchange (ETDEWEB)

The adverse effects and diagnostic accuracy of thallium-201 myocardial SPECT after intravenous infusion of adenosine triphosphate (ATP) were studied and compared with SPECT examinations with other type of loading. The subjects of the study were 147 patients with or without coronary artery disease, who underwent some type of loading SPECT and coronary arteriography (CAG) within 30 days. Myocardial ischemia was evaluated qualitatively in SPECT and was compared with CAG for the diagnostic accuracy of coronary artery disease. The degree of myocardial uptake defect was also calculated semiquantitatively using visual scoring method and compared with coronary artery severity score. The adverse effects occurred in 46.7% of ATP loading SPECT which was more frequent that DIP loading SPECT, but all of them were transient and mild. As for the diagnostic ability the ATP loading SPECT was as effective as other type of loading in ...

1999-09-01

263

Radiation hardening of diagnostics  

International Nuclear Information System (INIS)

The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted ...

264

Radial distribution of superthermal electrons measured with ECE (abstract)  

International Nuclear Information System (INIS)

To aid in the study of lower hybrid current drive as a means of current profile control, the radial profile and velocity distribution of the fast current-carrying electrons and their time evolution must be known. As part of the recent effort to understand this fast electron transport, a diagnostic has been installed on PBX-M to measure the electron cyclotron emission from the fast electrons. An oblique horizontal view of upshifted cyclotron emission in the midplane can give radial as well as velocity space information about the fast electrons. Emission in X mode frequencies refracted by the right-hand cutoff is radially localized. The observed emission at a specific frequency comes only from the radial region r_t_u_r_n=#0. Emission measured by this new diagnostic has been found to be radially localized as predicted. It is also expected that localized moments of the distribution function may be obtained from these data. A superheterodyne ...

0854-01-01

265

Optical diagnostics for turbulent and multiphase flows: Particle image velocimetry and photorefractive optics  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the work performed under the Sandia Laboratory Directed Research and Development (LDRD) project ``Optical Diagnostics for Turbulent and Multiphase Flows.`` Advanced optical diagnostics have been investigated and developed for flow field measurements, including capabilities for measurement in turbulent, multiphase, and heated flows. Particle Image Velocimetry (PIV) includes several techniques for measurement of instantaneous flow field velocities and associated turbulence quantities. Nonlinear photorefractive optical materials have been investigated for the possibility of measuring turbulence quantities (turbulent spectrum) more directly. The two-dimensional PIV techniques developed under this LDRD were shown to work well, and were compared with more traditional laser Doppler velocimetry (LDV). Three-dimensional PIV techniques were developed and tested, but due to several experimental difficulties were not as successful. ...

1997-01-01

266

Myocardial perfusion SPECT in patients after myocardial infarction: Comparison of "2"0"1Tl and dual-isotope protocol (rest "2"0"1Tl/stress "9"9"mTc tetrofosmin)  

International Nuclear Information System (INIS)

The diagnostic accuracy is compared of the dual-isotope protocol and the conventional "2"0"1Tl protocol, for detection of the coronary artery disease (CAD) using data on a total of 69 patients after myocardial infarction (MI). The "2"0"1Tl protocol was used to examine 44 patients, the dual-isotope protocol was used with 25 patients. All patients were examined by coronarography; a narrowing of the artery by more than 50 % was considered significant for CAD. The sensitivity, specificity and diagnostic accuracy was 97.7 %, 100 % and 97.7 % resp. for the "2"0"1Tl protocol, and 95.2 %, 75 % and 92 % resp. for the dual-isotope protocol. A higher diagnostic accuracy of the dual-isotope protocol has not been proven, and the "2"0"1Tl protocol continues to be used for examinations of patients after MI

1998-08-01

267

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...

268

MTX diagnostic and timing system for free-electron laser heating experiments  

International Nuclear Information System (INIS)

In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of heating effects on the ...

269

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil  

International Nuclear Information System (INIS)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...

270

He-like ions as practical astrophysical plasma diagnostics: From stellar coronae to active galactic nuclei  

CERN Document Server

We review X-ray plasma diagnostics based on the line ratios of He-like ions. Triplet/singlet line intensities can be used to determine electronic temperature and density, and were first developed for the study of the solar corona. Since the launches of the X-ray satellites Chandra and XMM-Newton, these diagnostics have been extended and used (from CV to Si XIII) for a wide variety of astrophysical plasmas such as stellar coronae, supernova remnants, solar system objects, active galactic nuclei, and X-ray binaries. Moreover, the intensities of He-like ions can be used to determine the ionization process(es) at work, as well as the distance between the X-ray plasma and the UV emission source for example in hot stars. In the near future thanks to the next generation of X-ray satellites (e.g., Astro-H and IXO), higher-Z He-like lines (e.g., iron) will be resolved, allowing plasmas with higher temperatures and densities to be probed. Moreover, the ...

2011-01-01

271

Estimation of population doses from medical uses of radiopharmaceuticals in Japan, 1977, 2  

International Nuclear Information System (INIS)

Population doses from diagnostic and therapeutic uses of radiopharmaceuticals have been estimated on the basis of a nation wide survey data on the number of investigations and treatments used radiopharmaceuticals in the nuclear medicine and the annual amount of their activities. The gonad and marrow doses were calculated from published biokinetics data from humans, employing the MIRD method. The resultant annual genetically significant dose from diagnostic and therapeutic uses of radiopharmaceuticals was 0.36 and 0.02 mrad (3.6 and 0.2 #mu#Gy) per person, respectively, with a total 0.38 mrad (3.8 #mu#Gy) per person. The annual per Caput mean bone marrow dose was 2.3 mrad (23 #mu#Gy) for diagnosis and 0.2 mrad (2 #mu#Gy), for therapy. The resultant annual leukemia significant dose was 1.8 mrad (18 #mu#Gy) per person for diagnostic uses and 0.2 mrad (2 #mu#Gy) per person for therapeutic use, with a total of 2.0 mrad (20 ...

1979-01-01

272

Design of the electromagnetic fluctuations diagnostic for MFTF-B  

Energy Technology Data Exchange (ETDEWEB)

The Electromagnetic Fluctuations (EMF) diagnostic will be used to monitor ion fluctuations which could be unstable in MFTF-B. Each probe assembly includes a high impedance electrostatic probe to measure potential fluctuations, and a group of nested, single turn loops to measure magnetic fluctuations in three directions. Eventually, more probes and loops will be added to each probe assembly for making more detailed measurements. The sensors must lie physically close to the plasma edge and are radially positionable. Also, probes at separate axial locations can be positioned to connect along the same magnetic field line. These probes are similar in concept to the rf probes used on TMX, but the high thermal load for 30-second shots on MFTF-B requires a water-cooled design along with temperature monitors. Each signal channel has a bandwidth of .001 to 150 MHz and is monitored by up to four different data channels which obtain amplitude and frequency information. This ...

1983-11-28

273

Achievement report for fiscal 1998. Research and development of a multi-plant maintenance system (the first year); 1998 nendo seika hokokusho. Odanteki maintenance gijutsu no kenkyu kaihatsu (dai 1 nendo)  

Energy Technology Data Exchange (ETDEWEB)

This research and development is intended to structure a network centering around a center having systematized high-level maintenance technology, by utilizing the technological infrastructure having been built in local areas, together with element technologies possessed by national and private research institutes, universities and colleges. It is also purposed to establish a new industrial system for maintenance to realize high reliability, high operation rate and low cost in plants in certain areas. The present fiscal year had the following achievements: research and development of a maintenance system, a maintenance model, a maintenance vehicle, damage estimating technology for stationary parts such as piping, an anomaly diagnostic system using acoustic emission, an anomaly diagnostic system using wear particles in lubricant, an anti-wear material using surface modification, a lubrication control system, and an anomaly ...

1999-03-01

274

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)  

International Nuclear Information System (INIS)

T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic ...

275

When Top-Down Meets Bottom-Up: Auditory Training Enhances Verbal Memory in Schizophrenia  

UK PubMed Central (United Kingdom)

A critical research priority for our field is to develop treatments that enhance cognitive functioning in schizophrenia and thereby attenuate the functional losses associated with the illness. In this...Full Text Available

2009-11-01

276

Transposons as tools for enhancer trap screens in vertebrates  

UK PubMed Central (United Kingdom)

DNA transposons are efficient tools in transgenesis and have therefore become popular in the analysis of the regulatory genome in vertebrates via enhancer trap screens. Here, I discuss recent progress...Full Text Available

2007-01-01

277

The Differing Impact of Multisensory and Unisensory Integration on Behavior  

UK PubMed Central (United Kingdom)

Pooling and synthesizing signals across different senses often enhances responses to the event from which they are derived. Here we examine whether multisensory response enhancements are attributable...Full Text Available

2009-04-15

278

Resonance Raman enhancement of phenyl ring vibrational modes in phenyl iron complex of myoglobin.  

UK PubMed Central (United Kingdom)

Resonance Raman spectra are reported for the organometallic phenyl-FeIII complexes of horse heart myoglobin. We observed the resonance enhancement of the ring vibrational modes of the bound phenyl group....Full Text Available

1990-04-01

279

Regional Convection-Enhanced Delivery of Gadolinium-labeled Albumin in the Rat Hippocampus In Vivo  

UK PubMed Central (United Kingdom)

Convection-enhanced delivery (CED) has emerged as a promising method of targeted drug-delivery for treating central nervous system (CNS) disorders, but the influence of brain structure on infusate...Full Text Available

2010-03-15

280

Precise temporal control of the eye regulatory gene Pax6 via enhancer-binding site affinity  

UK PubMed Central (United Kingdom)

How transcription factors interpret the cis-regulatory logic encoded within enhancers to mediate quantitative changes in spatiotemporally restricted expression patterns during animal...Full Text Available

2010-05-15

281

Plasma Treatment of Surfaces and Plasma Enhanced Deposition.  

Science.gov (United States)

This report results from a contract tasking Eindhoven University of Technology as follows: The contractor will investigate the plasma treatment of surfaces and plasma enhanced deposition using EUT's cascade arc source as the basis for this effort.

1997-01-01

282

Molecular biological enhancement of coal biodesulfurization. Final report, October 1988--December 1991  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this project was to use molecular genetics to develop strains of bacteria with enhanced ability to remove sulfur from coal, and to obtain data that will allow the performance and economics of a coal biodesulfurization process to be predicted. (VC)

1991-12-01

283

K Kiosk - NIH Extramural Training: Information about NIH Career...  

Science.gov (United States)

Established Investigators (K18) (PAR-09-090) NIH: Career Enhancement Award for Stem Cell Research (K18) (PA-09-110) NIDCD: NIDCD Research Career Enhancement Award for Established...

2011-10-01

284

Image-Guided Convection-Enhanced Delivery Platform in the Treatment of Neurological Diseases  

UK PubMed Central (United Kingdom)

SummaryConvection-enhanced delivery (CED) of substances within the human brain is becoming a more frequent experimental treatment option in the management of brain tumors, and...Full Text Available

2008-01-01

285

Heat Stress Enhances the Accumulation of Polyadenylated Mitochondrial Transcripts in Arabidopsis thaliana  

UK PubMed Central (United Kingdom)

BackgroundPolyadenylation of RNA has a decisive influence on RNA stability. Depending on the organisms or subcellular compartment, it either enhances transcript stability or targets...Full Text Available

286

Enhancing fraction measured using dynamic contrast-enhanced MRI predicts disease-free survival in patients with carcinoma of the cervix  

UK PubMed Central (United Kingdom)

Background:There is a need for simple imaging parameters capable of predicting therapeutic outcome.Methods:This retrospective study analysed 50 patients...Full Text Available

2010-01-05

287

Enhanced CT and CT virtual endoscopy in diagnosis of heterotopic pancreas  

UK PubMed Central (United Kingdom)

AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available

2011-09-07

288

Convection-enhanced delivery of maghemite nanoparticles: Increased efficacy and MRI monitoring  

UK PubMed Central (United Kingdom)

Convection-enhanced drug delivery (CED) is a novel approach to delivering drugs into brain tissue. Drugs are delivered continuously via a catheter, enabling large volume distributions of high drug concentrations...Full Text Available

2008-04-01

289

Convection-enhanced Delivery of Free Gadolinium with the Recombinant Immunotoxin MR1-1  

UK PubMed Central (United Kingdom)

PurposeA major obstacle in glioblastoma (GBM) therapy is the restrictive nature of the blood-brain barrier (BBB). Convection-enhanced delivery (CED) is a novel method...Full Text Available

2010-05-01

290

Wideband Modulation and Tuning of Semiconductor Lasers ...  

Science.gov (United States)

... Tunable semiconductor lasers are essential components for links employing optical frequency modulation (OFM) for enhanced dynamic range or ...

1996-07-01

291

Tests of Turbulators for Fire-Tube Boilers.  

Science.gov (United States)

... Originator-supplied keywords include: Turbulators, Heat transfer augmentation, Enhancement, Fire tube boilers. (Author). ...

1982-10-01

292

Selective enhancement of barium in the atmospheres of red giants  

Energy Technology Data Exchange (ETDEWEB)

High-resolution spectroscopy of 13 bright red giants and Ba stars shows selective enhancement of Ba in three of them, HD 65699 (Ba 2), ..cap alpha..TrA (K4 III), and epsilonPeg (K2 Ib). Infrared spectra available for HD 65699 show that Sr is enhanced, too. This selective enhancement is discussed in terms of a modified s-process which converts some of the pre-existing r- and s-process matter into the magic nuclei /sup 88/Sr and /sup 138/Ba.

1984-03-01

293

Research workshop on energy conservation through enhanced heat transfer  

Science.gov (United States)

Seven papers were presented at the meeting. A separate abstract was prepared for each paper. (LCL)

1979-10-01

295

Precipitation, phase transformation, and enhanced diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

This paper describes Z-contrast scanning transmission electron microscopy used to study the connection between dopant precipitation and phase transformation in high dose In"+ and Sb"+ implanted Si. In the case of In, the observations confirm a heterogeneous nucleation model. Images of the precursor precipitates give the first measurement of the diffusion coefficient in amorphous Si, with an enhancement of 10"7 over tracer crystalline values. With Sb"+ implants enhanced homogeneous nucleation is observed. The connection between these results and the transient enhanced diffusion observed in crystallized Si is discussed.

296

Package Enhancement Study for the 120-mm M831E2 ...  

Science.gov (United States)

... Descriptors : *AMMUNITION, *CONTAINERS, *CARTRIDGES, *COMBUSTIBLE CARTRIDGE CASES, *CARTRIDGE CASES, *ANTITANK ...

1992-07-01

297

Nuclear forensics. The science for enhancing nuclear security  

International Nuclear Information System (INIS)

Japanese ... Authors Kuno, Yusuke; Esaka, Konomi (Tokyo Univ., Graduate School of Engineering, Tokyo (Japan))

2011-01-01

299

Human Auditory Localization Performance in Azimuth  

Science.gov (United States)

... The realization of directional audio technology in the cockpit may reduce visual workload, enhance the presentation of flight and threat information ...

1991-01-01

303

Enhanced Core Noise Modeling for Turbofan Engines  

Science.gov (United States)

This report describes work performed by MTC Technologies (MTCT) for NASA Glenn Research Center (GRC)

2011-01-01

305

Combating Terrorism and Enhancing Regional Stability and ...  

Science.gov (United States)

... Uninterrupted access to and use of critical infrastructure in the Arabian Gulf region are key to the successful prosecution of the Global War on Terror ...

2004-11-01

307

The tactical use of constraints and structure in diagnostic problem solving  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a prescriptive account of diagnostic problem solving, or diagnosis, in quality and process control. This paper identifies a general strategy, named branch-and-prune, whose manifestations can be found in disciplines such as medical diagnosis, troubleshooting of devices, and model-based diagnosis in artificial intelligence. The work aims to offer a clear conceptualization of this strategy, based on the notions of structures for the search space, and constraints to the cause's nature.The idea is to treat the search space of candidate explanations as a tree structure, in which general and high-level causal directions are branched into more specific and detailed explanations. Constraints eliminate all but a few branches (pruning), which are explored in more detail. We enumer...

2011-01-01

308

Somatic effects in nuclear medicine and radiology  

International Nuclear Information System (INIS)

Probable risks for the occurrence of somatic effects due to diagnostic radiology and nuclear medicine are summarised. The biological background of radiation carcinogenesis and epidemiological results are discussed. At the Leiden University Medical Centre the average effective dose per examination due to diagnostic radiology and nuclear medicine amount to 0.95 and 4.4 mSv, respectively. These values correspond well with the average values of 0.82 and 3.0 mSv reported for The Netherlands as a whole. Since radiological examinations are performed at a much larger frequency than nuclear medicine the relative collective dose for the first type of examinations is higher than the latter. Risk for occurency of malignancies are at least one order of magnitude lower than the hypothetical risk due to the background radiation typical of The Netherlands.

1999-01-01

309

Plasma diagnostics by spectra from LHD and atomic data  

International Nuclear Information System (INIS)

We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)

2009-04-01

310

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for the conditions ...

1995-12-31

311

Interaction of dioxygen with the electronic excited state of Ir(III) and Ru(II) complexes: Principles and biomedical applications  

British Library Electronic Table of Contents (United Kingdom)

Luminescent transition metal complexes are enjoying a growing interest because of their ubiquitous applications in, e.g., the fields of material science, sensors and (biomedical) diagnostics, and iridium(III) and ruthenium(II) complexes are among the best studied. Due to their long-living excited states, these complexes can have a strong interaction with dioxygen, resulting in luminescence quenching. This oxygen quenching might be regarded as an unwanted effect in luminescence imaging, but, on the other hand, it can be exploited for diagnostic and therapeutic applications as well. After a theoretical introduction concerning the dioxygen quenching mechanism and the parameters involved, in the second part of this review we focus on the possibility of tailoring this quenching by modifying sel...

2011-01-01

312

Identification and staging of bladder carcinoma  

International Nuclear Information System (INIS)

The purpose of the present study was to compare the effectiveness of MRI, CT and radioimmunoscintigraphy in the staging and detection of bladder cancers in 28 patients. We distinguish two groups: Group I included the tumour stages CIS-T_3_A and the second group the deep infiltrative tumours T_3_B-T_4. MRI was slightly superior to CT in respect of tumour staging (75% correct results as compared to 63%). No understaging occurred with MRI, whereas in 22% of the cases the stage of the tumour was underestimated using CT diagnostics. Overstaging occurred in 25% of the MRI and 15% of the CT-diagnostics, respectively. RIS cannot distinguish the tumour groups, and hence this method is useful only for the detection of the primary tumour and metastases. In 77% of cases the tumour was detected and in 15% the tumour could be safely excluded. (orig.).

313

Fundamental limits on beam stability at the advanced photon source  

International Nuclear Information System (INIS)

Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.

1998-12-10

314

Endofibrosis of Iliac Arteries in High-Performance Athletes: Diagnostic Approach and Minimally Invasive Endovascular Treatment  

International Nuclear Information System (INIS)

The aim of this article is to report our experience in the diagnosis of two cases of iliac artery endofibrosis or arteriopathy, a rare entity occurring in high-performance athletes, presenting with intermittent claudication (right-sided in both) after maximal exercise. External iliac artery endofibrosis or arteriopathy is a likely diagnosis in competitive athletes free of cardiovascular risk factors who present with leg claudication. Arteriography and a papaverine-assisted mean pressure gradient across the iliac arteries of more than 10 mmHg is a useful diagnostic approach. Moreover, balloon angioplasty of the iliac artery in that patient, in whom a pressure gradient was detected, resulted in symptomatic relief for 2 months followed by mild symptom recurrence. Thus, although balloon angioplasty is feasible and safe, it might not be adequate to treat this entity and, thus, its value remains undefined.

2006-10-01

315

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants  

International Nuclear Information System (INIS)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

316

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

317

Cost minimization analysis for combinations of sampling techniques in bronchoscopy of endobronchial lesions  

British Library Electronic Table of Contents (United Kingdom)

SummaryBackground The choice of sampling techniques in bronchoscopy with sampling from a visible lesion will depend on the expected diagnostic yields and the costs of the sampling techniques. Aims The aim of this study was to determine the most economical combination of sampling techniques when approaching endobronchial visible lesions. Methods A cost minimization analysis was performed. All bronchoscopies from 2003 and 2004 at Haukeland university hospital, Bergen, Norway, were reviewed retrospectively for diagnostic yields. 162 patients with endobronchial disease were included. Potential sampling techniques used were biopsy, brushing, endobronchial needle aspiration (EBNA) and washings. Costs were estimated based on registration of equipment costs and personnel costs. Sensitivity analyse...

2009-01-01

318

Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures  

International Nuclear Information System (INIS)

The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.

319

A method of stereotaxic localization adopted for conventional and digital radiography  

International Nuclear Information System (INIS)

A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be transferred to various therapeutic or ...

1986-01-01

320

A comprehensive condition monitoring system for hydro-electric generating units  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a comprehensive MCM [machine condition monitoring] program and suggested system for implementation in hydroelectric generating units. The system addresses all the major subsystems which make up the generating unit. A modular design means that it could be applicable in a wide variety of situations. Different subsystems may be included or excluded from the monitoring system as required. It may be used at individual plants as a stand alone system or network wide. An advanced processing and diagnostic module is included, again for use as an integral part of the system or as a stand alone analysis tool. Examples of the system's proposed data analysis and diagnostic abilities are also described using vibration signals as would be provided by the bearing module. (Author)

1994-04-01

321

A complete census of AGN and their hosts from optical surveys?  

CERN Document Server

Large optical surveys provide an unprecedented census of galaxies in the local Universe, forming an invaluable framework into which more detailed studies of objects can be placed. But how useful are optical surveys for understanding the co-evolution of black holes and galaxies, given their limited wavelength coverage, selection criteria, and depth? In this conference paper I present work-in-progress comparing optical and mid-IR diagnostics of three "unusual" low redshift populations (luminous Seyferts, dusty Balmer-strong AGN, ULIRGs) with a set of ordinary star-forming galaxies from the SDSS. I address the questions: How well do the mid-infrared and optical diagnostics of star formation and AGN strength agree? To what extent do optical surveys allow us to include extreme, dusty, morphologically disturbed galaxies in our "complete" census of black hole-galaxy co-evolution?

2010-01-01

322

Transient enhanced diffusion and deactivation of ion-implanted As in strained Si  

International Nuclear Information System (INIS)

First results on the effects of strain on transient enhanced diffusion and deactivation of As-implanted ultrashallow junctions are presented. A significant effect of strain on the magnitude and timescale of transient enhanced diffusion is observed, which is consistent with the stabilization of interstitial-type defects by tensile strain. Our results show no significant impact of strain on As electrical activity during the deactivation timescale accessed in this study.

2005-08-01

323

The enhancement of three-party simultaneous quantum secure direct communication scheme with EPR pairs  

Science.gov (United States)

Recently, Wang et al. proposed a three-party simultaneous quantum secure direct communication (3P-SQSDC) scheme with EPR pairs, which enables three involved parties to exchange their secret messages simultaneously by using an EPR pair. This work proposed an enhancement on Wang et al.'s scheme. With the enhancement, the communications in the improved 3P-SQSDC can be paralleled and thus improves the protocol efficiency.

2011-01-01

324

Study of transient enhanced dopant diffusion in silicon and proposed limiting methods  

International Nuclear Information System (INIS)

The transient enhanced diffusion in crystalline silicon implanted with dopants ad followed by high temperature annealing to activate the dopants is introduced. The physical mechanisms of transient enhanced dopant diffusion are then reviewed together with a short introduction to the proposed suppressing methods. Finally, the perspectives with using high energy heavy ions in this field are briefly discussed

2001-09-01

325

On the theory of transient enhanced diffusion in boron-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion in boron-implanted silicon is interpreted as being due to the fact that during rapid thermal annealing a relaxation process takes place, associated with quasi-chemical reactions including defects. A simple analytical model makes it possible to describe the annealing mechanism on a microscopic scale in terms of reaction-diffusion processes. The measured dependences of the boron diffusion coefficient of the enhanced diffusion on time, temperature and implantation energy are satisfactorily explained. (author).

1991-01-01

326

On the theory of transient enhanced diffusion in boron-implanted silicon  

International Nuclear Information System (INIS)

Transient enhanced diffusion in boron-implanted silicon is interpreted as being due to the fact that during rapid thermal annealing a relaxation process takes place, associated with quasi-chemical reactions including defects. A simple analytical model makes it possible to describe the annealing mechanism on a microscopic scale in terms of reaction-diffusion processes. The measured dependences of the boron diffusion coefficient of the enhanced diffusion on time, temperature and implantation energy are satisfactorily explained. (author).

327

Heat exchange enhancement structure  

Energy Technology Data Exchange (ETDEWEB)

A passive heat exchange enhancement structure which operates by free convection includes a flat mounting portion having a plurality of integral fins bent outwardly from one side edge thereof. The mounting portion is securable around a stovepipe, to a flat surface or the like for transferring heat from the pipe through the fins to the surrounding air by rotation-enhanced free convection.

1980-12-02

328

Boron-enhanced-diffusion of boron: The limiting factor for ultra-shallow junctions  

Energy Technology Data Exchange (ETDEWEB)

Reducing implant energy is an effective way to eliminate transient enhanced diffusion (TED) due to excess interstitials from the implant. It is shown that TED from a fixed Si dose implanted at energies from 0.5 to 20 keV into boron doping-superlattices decreases linearly with decreasing Si ion range, virtually disappearing at sub-keV energies. However, for sub-keV B implants diffusion remains enhanced and x{sub j} is limited to {ge} 100 nm at 1,050 C. The authors term this enhancement, which arises in the presence of B atomic concentrations at the surface of {approx} 6%, Boron-Enhanced-Diffusion (BED).

1997-12-01

329

CT diagnosis of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To evaluate contrast-enhanced CT scan in the diagnosis of intrahepatic cholangiocarcinoma by correlating the CT appearance with pathologic specimens. Materials and methods: Twenty-eight patients with pathologically proven intrahepatic cholangiocarcinoma were examined. Unenhanced abdominal CT study were performed in 28 patients; conventional contrast-enhanced CT in 27 patients. Enhanced CT scan including fast injection, fast scan and delayed scan at the largest section of the lesion was done in 7 patients. Contiguous 10 mm CT scans of the surgical specimens were also obtained in 8 patients. The preoperative and specimen CT scans in these 8 patients were compared with the corresponding pathological sections. A total of 103 areas of the pathological sections was compared with the CT appearances. Results: All lesions contained areas of delayed contrast enhancement and/or no ...

330

[Hormonal disorders in chronic alcoholic intoxication].  

Science.gov (United States)

Hormone levels were examined in the venous blood in 54 men suffering from stage 2 alcoholism and in 30 normal subjects, using a radioimmunochemical assay. The alcoholics were found to have a statistically significant increase in prolactin and a decrease in testosterone. A definite ratio in the secretion of these hormones differing from that in the control group was elucidated. This ratio (prolactin-testosterone index) is proposed as a diagnostic test of alcoholism. PMID:6441404

1984-01-01

331

Uncommon bone tumors of the skull: Ewing's sarcoma and Triton's tumor  

International Nuclear Information System (INIS)

Ewing's sarcoma and Triton's tumor are two uncommon bone tumors of the skull that have nonspecific clinical and imaging features. However, imaging methods are important in the detection of the lesions during the diagnostic investigation in order to evaluate the extent of the bone lesions, involvement of the soft tissues and brain, and to determine the presence of local recurrence and metastases. The confirmatory diagnosis relies on histological studies and immunohistochemistry. The authors report two cases of patients with these tumors and present the radiological findings. (author)

332

Thermal reactor safety  

International Nuclear Information System (INIS)

Information is presented concerning new trends in licensing; seismic considerations and system structural behavior; TMI-2 risk assessment and thermal hydraulics; statistical assessment of potential accidents and verification of computational methods; issues with respect to improved safety; human factors in nuclear power plant operation; diagnostics and activities in support of recovery; LOCA transient analysis; unresolved safety issues and other safety considerations; and fission product transport.

1990-09-01

333

Thermal reactor safety  

Energy Technology Data Exchange (ETDEWEB)

Information is presented concerning new trends in licensing; seismic considerations and system structural behavior; TMI-2 risk assessment and thermal hydraulics; statistical assessment of potential accidents and verification of computational methods; issues with respect to improved safety; human factors in nuclear power plant operation; diagnostics and activities in support of recovery; LOCA transient analysis; unresolved safety issues and other safety considerations; and fission product transport.

1980-06-01

334

The urine test strip of the future.  

Science.gov (United States)

The aim of the classical multiple test strip is to perform routine chemical analysis in one single operation, yielding maximum diagnostic and prognostic information. A maximum of 10 test areas should not be exceeded. The efficiency of the currently marketed test strips is discussed and improvements within acceptable price limits are suggested. PMID:10841930

2000-07-01

335

The scintigraphy of the brain: development, methods and present consequence  

International Nuclear Information System (INIS)

Brain scintiscanning which was first carried out exclusively 'statical' and only with test substances of limited quality has been replaced nowadays by 'dynamical' camera-sequency-scintiscanning with technetium. This brought considerable progress not only for identifying but also for the differential diagnosis of cerebro-organic processes. Development, methods, and integration of brain scintiscanning in a diagnostical conception are described briefly. (orig.).

336

Techniques and tools for condition monitoring and life prediction of fluid power controls used in fuel handling systems of PHWRs  

International Nuclear Information System (INIS)

Various diagnostics techniques for condition monitoring and life prediction of fluid power components and system are discussed. Though some of the techniques are very promising but may not be accepted because of increase in the instrumentation, it is planned to implement these techniques on various circuits of Fluid Power Lab for further improving and developing these for direct implementation in various fluid power circuits of power reactors. (author). 6 figs.

337

Spot size and Guoy phase invariant telescope for auto-alignment of resonant cavities  

International Nuclear Information System (INIS)

We present both the theory and an experimental method to accurately set up a Guoy phase telescope, where both the output spot size and orthogonality condition are invariant to distance from the cavity beam waist. We demonstrate that Gaussian spot size measurements can be used as a diagnostic to determine the desired locations of split area photodetectors. The Guoy phase invariance is verified using the tilt-locking technique.

2004-03-07

338

Spectroscopic study of some historical arts  

International Nuclear Information System (INIS)

This work presents the spectroscopic results of the investigations of ancient pottery remains excavated in ancient Kremna (BURDUR-TURKEY). The micro-Raman and FT-IR spectroscopic studies of the pottery remains belonging to sixth century allowed us to identify the mineral composition. Some examples are described of the use of this technique in the field of art conservation and diagnostics, with regard to pigments, and some products of metal alteration.

2009-09-24

339

Signal processing methods for MFE plasma diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The application of various signal processing methods to extract energy storage information from plasma diamagnetism sensors occurring during physics experiments on the Tandom Mirror Experiment-Upgrade (TMX-U) is discussed. We show how these processing techniques can be used to decrease the uncertainty in the corresponding sensor measurements. The algorithms suggested are implemented using SIG, an interactive signal processing package developed at LLNL.

1985-02-01

340

Screen-film-combinations for radiography - present and future spectrum of application  

Energy Technology Data Exchange (ETDEWEB)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.

1985-01-01

341

Screen-film-combinations for radiography - present and future spectrum of application  

International Nuclear Information System (INIS)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).

342

Roentgenologic appearance of a thorotrast-induced small cholangiocarcinoma in a case of thorotrastosis  

International Nuclear Information System (INIS)

A small cholangiocarcinoma was detected at autopsy in a patient with thorotrastosis who died from the rupture of esophageal varices at the esophagogastric junction. Prior to the advent of recent diagnostic imaging technique, a correct antemortem diagnosis could only be obtained from tumor markers. However, the tendency for the opacity of the liver to decrease slowly with time and develop uneven trabeculation suggests that small tumors may be difficult to detect against such a non-homogeneous background. (author).

343

Researches on Plasma Physics and Controlled Fusion in IPP NSC KIPT  

International Nuclear Information System (INIS)

Recent results of experimental and theoretical investigations, carried out in the Institute of plasma Physics of the NSC KIPT, are presented in the report. The main problems of discussion are as follows: plasma confinement and heating in stellarators and electromagnetic traps; powerful quasi-steady-state plasma accelerators (QSPA); experiments relevant for ITER; fusion Plasma theory; methods of high temperature plasma diagnostics; plasma technology. The main prospects on the IPP investigators are discussed also.

2006-01-01

344

Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol; Indicacion de las tecnicas de diagnostico por la imagen en la sospecha de apendicitis aguda: propuesta de protocolo diagnostico  

Energy Technology Data Exchange (ETDEWEB)

To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, ...

2001-07-01

345

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit  

International Nuclear Information System (INIS)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.)

346

Radiation hazards from medical applications  

International Nuclear Information System (INIS)

An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).

1980-05-31

347

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

348

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

349

Plasma-optic separation and diagnostics results of division spent nuclear fuel  

International Nuclear Information System (INIS)

The possibility of separation in plasma-mass-separator POMS-E-3 spent nuclear fuel (SNF) in 3 fractions: transuranic elements, and two groups of fission products. New scheme of compact energy-mass analyzer for monitoring the separation process spent nuclear fuel in the POMS-E- 3 offered.

350

Patient doses from medical uses of x-rays  

International Nuclear Information System (INIS)

A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.

1981-01-01

351

Optimizing Antigen Cocktails for Detection of Mycobacterium bovis in Herds with Different Prevalences of Bovine Tuberculosis: ESAT6-CFP10 Mixture Shows Optimal Sensitivity and Specificity?  

UK PubMed Central (United Kingdom)

Bovine tuberculosis is a major problem in many countries; hence, new and better diagnostic tools are urgently needed. In this work, we have tested ESAT6, CFP10, PE13, PE5, MPB70, TB10.4, and TB27.4...Full Text Available

2006-12-01

352

Optical diagnostics based on elastic scattering: Recent clinical demonstrations with the Los Alamos Optical Biopsy System  

Energy Technology Data Exchange (ETDEWEB)

A non-invasive diagnostic tool that could identify malignancy in situ and in real time would have a major impact on the detection and treatment of cancer. We have developed and are testing early prototypes of an optical biopsy system (OBS) for detection of cancer and other tissue pathologies. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the microscopic structure of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be strongly wavelength ...

1993-08-01

353

New techniques of power transformers monitoring and diagnostic; Novas tecnicas de monitoramento e diagnostico de transformadores de potencia  

Energy Technology Data Exchange (ETDEWEB)

This article describes the techniques for monitoring electric power transformers applied by the Light to select and recover critical unities. The plan involved 20 and 40 MV A equipment and, as a reflex of the technique application, presented a substantial failure reduction.

2003-04-01

354

New concept to optimize emergency diagnoses in patients with multiple injuries  

International Nuclear Information System (INIS)

To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).

355

Modularity for bio business growth  

British Library Electronic Table of Contents (United Kingdom)

Interchangeable technology from Flexicon Liquid Filling, a business division of Watson-Marlow Pumps Group, has helped family-run diagnostic reagent manufacturer, Hart Biologicals Ltd, to accommodate business growth with the recent upgrade to a tabletop bottle filling and capping machine. A peristaltic dispensing pump is crucial for succes

2011-01-01

356

Modeled Neutron Induced Nuclear Reaction Cross Sections for Radiochemistry in the region of Iridium and Gold  

International Nuclear Information System (INIS)

We have developed a set of modeled nuclear reaction cross sections for use in radiochemical diagnostics. Systematics for the input parameters required by the Hauser-Feshbach statistical model were developed and used to calculate neutron induced nuclear reaction cross sections for targets ranging from osmium (Z = 76) to gold (Z = 79). Of particular interest are the cross sections on Ir and Au including reactions on isomeric targets.

2008-02-01

357

Machine condition monitoring  

Energy Technology Data Exchange (ETDEWEB)

A consortium has been formed to undertake the design and development work necessary to establish a comprehensive machine condition monitoring (MCM) and diagnostic system for hydroelectric generating units. By working closely with participating utilities and interested manufacturers, the consortium is initiating the integration of existing and developing technologies into a comprehensive, modular, on- and off-line hydroelectric MCM system.

1995-12-31

358

Lung studies with spiral CT. pitch 1 versus pitch 2  

International Nuclear Information System (INIS)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.

1999-03-01

359

Life time management at the Dukovany nuclear power plant  

International Nuclear Information System (INIS)

The paper discusses the role of the Life Management Programme in ensuring a safe operation of the Dukovany nuclear power plant. The Programme involves the following major items: (i) primary circuit materials degradation assessment, (ii) pipeline damage control by the Flow Assisted Corrosion Monitoring and Prediction Programme, and (iii) the DIALIFE diagnostic system. (author)

360

Instrumentation and control improvements at Experimental Breeder Reactor II  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to describe instrumentation and control (I C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I C systems of the next generation of liquid metal reactor (LMR) plants.

1993-01-01

361

Instrumentation and control improvements at Experimental Breeder Reactor II  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to describe instrumentation and control (I&C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I&C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I&C systems of the next generation of liquid metal reactor (LMR) plants.

1993-03-01

362

Increased renal corticomedullary FDG activity in a patient of NHL-malignant or benign?  

International Nuclear Information System (INIS)

Authors describe diagnostic dilemma of differentiating pyelonephritis with lymphomatous involvement of kidney in a known case of lymphoma. FDG uptake pattern was non-discriminatory and pyelonephritis diagnosed retrospectively on follow up study. Authors emphasize the importance of recognition of features and subtle clues of infection evident on CT component of PET-CT. (author)

363

Importance of computer tomography in paediatric diagnostics of abdominal and pelvic tumours  

Energy Technology Data Exchange (ETDEWEB)

In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computer tomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computer tomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computer tomography for the diagnosis of abdominal and pelvic tumours is discussed.

1980-03-01

364

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

365

Gastrin releasing peptide (GRP) receptor targeted radiopharmaceuticals: A concise update  

Energy Technology Data Exchange (ETDEWEB)

The gastrin releasing peptide (GRP) receptor is becoming an increasingly attractive target for development of new radiolabeled peptides with diagnostic and therapeutic potential. The attractiveness of the GRP receptor as a target is based upon the functional expression of GRP receptors in several tumors of neuroendocrine origin including prostate, breast, and small cell lung cancer. This concise review outlines some of the efforts currently underway to develop new GRP receptor specific radiopharmaceuticals by employing a variety of radiometal chelation systems.

2003-11-01

366

First Outbreak of Multidrug-Resistant Klebsiella pneumoniae Producing both SHV-12-Type Extended-Spectrum ?-Lactamase and DHA-1-Type AmpC ?-Lactamase at a Korean Hospital  

UK PubMed Central (United Kingdom)

PurposeCoexistence of different classes of β-lactamases in a single bacterial isolate may pose diagnostic and therapeutic challenges. We investigated a spread of Klebsiella...Full Text Available

2008-02-29

367

Ewing's sarcoma of the sacrum  

International Nuclear Information System (INIS)

A lytic lesion with softtissue extension in the sacrum of a 47-year old man was needle-biopsied under computed tomographic (CT) guidance using an 18-gauge cutting needle. The cytologic appearance of the lesion and immunohistochemical staining were diagnostic of Ewing's sarcoma. Specifically, a new marker (O13) for the presence of glycoprotein p30/32 mic2 in Ewing's sarcoma was utilized. (orig.).

368

Evaluation of the rapid diagnostic test SDFK40 (Pf-pLDH/pan-pLDH) for the diagnosis of malaria in a non-endemic setting  

UK PubMed Central (United Kingdom)

BackgroundThe present study evaluated the SD Bioline Malaria Ag 05FK40 (SDFK40), a three-band RDT detecting Plasmodium falciparum-specific parasite lactate dehydrogenase...Full Text Available

369

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, ...

2003-03-15

370

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

International Nuclear Information System (INIS)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, ...

2003-03-01

371

Emission-Line versus Continuum Correlations in Active Galactic Nuclei  

CERN Document Server

The Baldwin Effect, a negative correlation between emission-line equivalent width and luminosity in active galactic nuclei, is still of interest as a diagnostic of accretion physics nearly thirty years after its discovery. This review examines recent developments in the study of correlations between line and continuum emission in AGNs, as measured both in ensembles and in individual sources.

2006-01-01

372

Differential optical absorption techniques for diagnostics of coal gasification. Technical progress report, October, November, December 1982  

Energy Technology Data Exchange (ETDEWEB)

The application of differential optical absorption (DOA) techniques for the in-situ determination of the chemical composition of coal gasification process streams is investigated. Absorption spectra of relevant molecular species and the temperature and pressure effects on DOA-determined spectral characteristics of these species will be determined and cataloged. A system will be configured, assembled, and tested.

1983-04-01

373

Diagnostic value of immediate CT after chemoembolization in patients with hepatocellular carcinoma: comparison with 2-3 week delayed CT  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol CT is a important modality for the diagnosis of hepatocellular carcinoma and compared is usually performed at 2-3 week after Lipiodol injection. Therefore, we assessed and the diagnostic value and merits of immediate CT after chemoembolization from there of 2-3 week delayed Lipiodol CT. Thirty three cases of chemoembolization which were performed both immediate CT after chemoembolization and 2-3 week delayed Lipiodol CT were reviewed retrospectively. They were divided into four grades according to pattern of lipiodol uptake by three radiologists. The diagnostic value of immediate Lipiodol CT was compared to delayed Lipiodol CT. Grade 0 was two cases(3.0%) and Grade 1 was seven cases(21.2%). In the cases of Grade 2(23/33, 69.7%), tumor uptake could be dishing wished from parenchymal uptake of Lipiodol by its density and pattern, Tumor uptake showed dense and homogeneous pattern, but parenchymal uptake revealed less dense and ...

1995-08-15

374

Diagnostic measurements on the great machines conditions of lignite surface mines  

Science.gov (United States)

An analysis of the diagnosis of loading and service dependability of a rail-mounted excavator used in surface lignite mining is described. Wheel power vibrations in electric motor bearings and electric motor input bearings to the gearbox were measured in situ, in horizontal, vertical, and axial directions. The data were analyzed using a mathematical relationship. The results are presented in a loading diagram that shows the deterioration and the acceptable lower bound of machine conditions over time. Work is continuing. 5 refs., 1 fig.

2005-07-01

375

Detection of aortoarterial graft infections by leukocyte scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

Infections of aortoarterial prostheses are serious, difficult to detect, and difficult to treat. Scintigraphy with indium-111 labeled autologous leukocytes is an accurate noninvasive method of assessing the presence and extent of such an infection. In three cases of aorto-arterial bypass graft infections, the leukocyte study was successful in establishing the diagnosis and in assessing the extent of infection. Other noninvasive diagnostic techniques are useful, but all have serious limitations. The leukocyte study alone appears to be free of likely sources of error.

1983-09-01

376

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

377

Current Status on Stress Diagnostic Kit and Detection Technology  

Energy Technology Data Exchange (ETDEWEB)

The accurate measurement of a stress level is one of the most important issues in a stress diagnosis and its measurement could be of great value in clinical medicine. Stress has a potent effect on the spirit and physical condition of an individual. There are various methods available for its measurement. Some of the commonly used techniques for the diagnosis of a stress level include analysis of the body fluids, questionnaire assessments, psychophysiological evaluations and by determining heart rate variability (HRV) of subjects. However, the existing diagnostic methods have several defects like, a low sensitivity, inaccuracy and long of operation time. In this report, we present a diagnostic technology to detect a stress level which is the origin of various diseases. This method can be of great help in providing an early diagnosis through a biosensor and might play a vital role in preventing diseases like hypochondria and hypertension. ...

2008-06-15

378

Concentration and Preservation of Very Low Abundance Biomarkers in Urine, such as Human Growth Hormone (hGH), by Cibacron Blue F3G-A Loaded Hydrogel Particles  

UK PubMed Central (United Kingdom)

Urine is a potential source of diagnostic biomarkers for detection of diseases, and is a very attractive means of non-invasive biospecimen collection. Nonetheless, proteomic measurement in urine...Full Text Available

2008-12-01

379

Computer tomography of orbita in children  

Energy Technology Data Exchange (ETDEWEB)

The experiences are described of the examination of orbita in children using computer tomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.

1983-07-01

380

Comprehensive, nonintercepting electron-beam diagnostics using spontaneous emission  

Energy Technology Data Exchange (ETDEWEB)

Characterization and optimization of electron-beam parameters are important aspects of optimizing free-electron laser (FEL) performance. The visible spontaneous emission ({lambda}{approximately}650 nm) from the 5-meter long undulator of the Boeing FEL experiment can be characterized in sufficient detail with a streak/spectrometer to deduce time-resolved electron-beam spatial position and profile, micropulse duration, and energy. 7 refs., 13 figs., 2 tabs.

1989-01-01

381

Commercially Available Antibodies to Human Tumour Necrosis Factor-? Tested for Cross-Reactivity with Ovine and Bovine Tumour Necrosis Factor-? using Flow Cytometric Assays  

UK PubMed Central (United Kingdom)

A thorough understanding of the immune system, including the role of different cytokines, during inflammatory diseases in ruminants could lead to the development of new diagnostic methods and treatments....Full Text Available

2004-01-01

382

Clinical application of FCR for the portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-08-01

383

Clinical application of FCR for the portable chest radiographs in ICU  

International Nuclear Information System (INIS)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-01-01

384

Clinical Procedures for Medical Technology Specialists  

CERN Document Server

Divided into diagnostic and treatment sections, this book provides a comprehensive overview of the most common medical procedures performed in modern clinical settings. Each section presents common names for the procedure; an outline of the disease or injury for which the procedure is performed; a brief review of the anatomical structures and physiological processes that are involved; staffing, equipment, and pre-procedure requirements; a detailed description of the procedure itself; and, a discussion of expected outcomes as well as potential complications. Each chapter includes a summary and

2010-01-01

385

Biological parameters of transgenic rabbits  

British Library Electronic Table of Contents (United Kingdom)

The investigations were conducted at the Center of Biotechnology and Molecular Diagnostics of the All-Russian Animal Husbandry Research Institute, where a number of valuable transgenic animals (rabbits, sheep, and pigs) have been produced over the course of 20 years. The article presents the blood indices of control and transgenic rabbits with an integrated insulin gene.

2011-01-01

386

Application of coherent lidar to ion measurements in plasma diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A coherent lidar system has been constructed for the measurement of alpha particles in a burning plasma. The lidar system consists of a pulsed CO{sub 2} laser transmitter and a heterodyne receiver. The receiver local oscillator is a cw, sequence-band CO{sub 2} laser operating with a 63.23 GHz offset from the transmitter.

1997-03-01

387

Amp-PCR: Combining a Random Unbiased Phi29-Amplification with a Specific Real-Time PCR, Performed in One Tube to Increase PCR Sensitivity  

UK PubMed Central (United Kingdom)

In clinical situations where a diagnostic real-time PCR assay is not sensitive enough, leading to low or falsely negative results, or where detection earlier in a disease progression would benefit the...Full Text Available

388

Advances in noise analysis for nuclear plant surveillance and diagnostics  

Energy Technology Data Exchange (ETDEWEB)

An automated surveillance and baseline noise signature acquisition system is being demonstrated at Sequoyah-1. A nonperturbing method is also being developed for monitoring the subcritical reactivity during initial core loading in LWRs, in fuel storage and processing facilities, and during postaccident recovery operations such as Three Mile Island-2. (DLC)

1980-01-01

389

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01

390

Peripheral cholangiocarcinoma : three-phase helical CT appearance  

International Nuclear Information System (INIS)

To analyze the enhancement patterns and morphology of peripheral cholangiocar-cinomas (CCs), as seen on three-phase helical CT. Three-phase helical CT scans of 25 cases of 24 patients with pathologically-proven CCs were retrospectively reviewed. After intravenous administration of contrast media, scans of the hepatic arterial phase (HAP) were obtained at 30 seconds, of the portal venous phase (PVP) at 70 seconds, and of the delayed phase (DP) at 3 minutes. Linear, dense, marginal enhancement was seen in 17 CCs (68%), mainly on HAP images (64%) while thick, band-like, peripheral enhancement was seen in 18 (72%), on either PVP (52%) or DP (44%). Internal enhancement was observed in 23 CCs (92%) on PVP (68%) and/or DP (88%), and 19 CCs (76%) among them showed incomplete enhancement of stippled and/or septated patterns. Most (76%) were seen throughout all three phases to be ...

1997-08-01

391

Ultraviolet upconversion luminescence enhancement in Yb3+/Er3+-codoped Y2O3 nanocrystals induced by tridoping with Li+ ions  

International Nuclear Information System (INIS)

Ultraviolet (UV) upconversion (UC) luminescence in Yb3+/Er3+-codoped yttrium oxide (Y2O3) nanocrystals can be enhanced by orders of magnitude via tridoping further with Li+ ions under diode laser excitation of 970 nm. Sensitized three-photon UC radiations at 390 and 409 nm, corresponding to the 4G11/2?4I15/2 and 4H9/2?4I15/2 of Er3+ ions, respectively, present an enhancement time of about 33 times, which is larger than the 24 times enhancement for the UC green radiation. The UV UC radiation at 320 nm that corresponds to the 2P3/2?4I15/2 of Er3+ ions has also been greatly enhanced. Theoretical calculations interpret that all the observed enhancement times of UV UC radiations arise from the prolonged lifetimes of their intermediate states.

2009-03-01

392

Heat transfer augmentation in a heat exchanger tube using a baffle  

International Nuclear Information System (INIS)

Heat transfer enhancement in a heat exchanger tube by installing a baffle is reported. The effect of baffle size and orientation on the heat transfer enhancement was studied in detail. Three different baffle arrangements were considered. The results show that for the vertical baffle, an increase in the baffle height causes a substantial increase in the Nusselt number but the pressure loss is also very significant. For the inclined baffles, the results show that the Nusselt number enhancement is almost independent of the baffle inclination angle, with the maximum and average Nusselt number 120% and 70% higher than that for the case of no baffle, respectively. For a given baffle geometry, the Nusselt number enhancement is increased by more than a factor of two as the Reynolds number decreased from 20,000 to 5000. Simulations were conducted by introducing another baffle to enhance heat ...

2007-04-01

393

Experimental study of the characteristics of solidification of stearic acid in an annulus and its thermal conductivity enhancement  

Energy Technology Data Exchange (ETDEWEB)

The thermal and heat transfer characteristics of stearic acid during the solidification processes were investigated experimentally in a vertical annulus energy storage system. The temperature distribution and temperature variations with time at different radial positions during the freezing processes were obtained. The thermal characteristics of the stearic acid, including movement of the solid-liquid interface in the radial direction, and the effects of Reynolds number on the heat transfer parameters were studied. The heat flux was estimated by using a simple approximate model. A new copper fin was designed and fixed to the electrical heating rod to enhance the thermal conductivity of the stearic acid. The results show that the new fin can enhance both the conduction and the natural convection heat transfer of the PCM, and the enhancement factor during solidification is estimated to be as high as 250%. The effect of the ...

2005-04-01

394

Experimental study of the characteristics of solidification of stearic acid in an annulus and its thermal conductivity enhancement  

Energy Technology Data Exchange (ETDEWEB)

The thermal and heat transfer characteristics of stearic acid during the solidification processes were investigated experimentally in a vertical annulus energy storage system. The temperature distribution and temperature variations with time at different radial positions during the freezing processes were obtained. The thermal characteristics of the stearic acid, including movement of the solid-liquid interface in the radial direction, and the effects of Reynolds number on the heat transfer parameters were studied. The heat flux was estimated by using a simple approximate model. A new copper fin was designed and fixed to the electrical heating rod to enhance the thermal conductivity of the stearic acid. The results show that the new fin can enhance both the conduction and the natural convection heat transfer of the PCM, and the enhancement factor during solidification is estimated to be as high as 250%. The effect of the ...

2005-04-01

395

Enhanced sludge washing evaluation plan  

Energy Technology Data Exchange (ETDEWEB)

The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced sludge washing. ...

1994-09-01

396

Diffusion modeling of ion implanted boron in Si during RTA: Correlation of extended defect formation and annealing with the enhanced diffusion of boron. [Rapid Thermal Annealing  

Energy Technology Data Exchange (ETDEWEB)

Accurate modeling of the enhanced diffusion of boron during rapid thermal annealing has been accomplished by incorporating the effects of extended defect formation and annealing on enhanced diffusion into a multizone, semiempirical model. The multizone model divides the implant profile into three zones defining regions of different defects and diffusion enhancements. The model also contains the initial enhanced diffusion and the transient diffusion effects associated with the dissolution of defect clusters and the annealing of extended defects, respectively. The saturation time for transient-enhanced diffusion contains an exponential function of implant dose in order to model the increase in point defect generated with higher implant dose. As a result, the model accurately simulates the boron diffusion profile over a wide range of implant doses and also shows the immobile boron peak ...

1993-01-01

397

Annealing and diffusion characteristics of boron-through-oxide implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

The author investigates the diffusion and damage-annealing characteristics as a result of boron implantation through a surface oxide into the silicon, a process that is commonly realized in the fabrication of p-n junctions. Defect structures were examined using plan-view and cross-section transmission-electron microscopies. It is shown that recoil-implanted oxygen plays a critical role in determining the above annealing characteristics. For instance, transient-enhanced diffusion of boron, as is widely observed for boron-implanted silicon, does not occur in the case of through-oxide implantation. The initial suppression of the defect-enhanced diffusion lasts for a limited period of time after which enhanced diffusion occurs again. The so-called incubated enhanced diffusion' is characterized as due to recoiled-oxygen precipitation-emitting point defect that enhances boron ...

1991-01-01

398

Annealing and diffusion characteristics of boron-through-oxide implanted silicon  

International Nuclear Information System (INIS)

The author investigates the diffusion and damage-annealing characteristics as a result of boron implantation through a surface oxide into the silicon, a process that is commonly realized in the fabrication of p-n junctions. Defect structures were examined using plan-view and cross-section transmission-electron microscopies. It is shown that recoil-implanted oxygen plays a critical role in determining the above annealing characteristics. For instance, transient-enhanced diffusion of boron, as is widely observed for boron-implanted silicon, does not occur in the case of through-oxide implantation. The initial suppression of the defect-enhanced diffusion lasts for a limited period of time after which enhanced diffusion occurs again. The so-called incubated enhanced diffusion' is characterized as due to recoiled-oxygen precipitation-emitting point defect that enhances boron motion. The ...

399

Ultrasonic enhancement of heat transfer on narrow surface  

Energy Technology Data Exchange (ETDEWEB)

Ultrasonic enhancement of heat transfer on a narrow surface was measured by changing the width of the surface from 8 to 0.1 mm. Ultrasonic power of 600 W with a frequency of 40 kHz was used. Heat transfer on the narrow surface without ultrasonic vibration was correlated by the experimental equation for a thin wire. The cavitation intensity was measured by the cavitation erosion loss of an aluminum foil of 15 [mu]m thickness. The effects of acoustic streaming and cavitation were separated by this measurement. Heat transfer by acoustic streaming was predicted through forced convection. Enhancement by cavitation was explained by the turbulence thermal conductivity of the microjets.

1994-06-01

400

Point defect supersaturation and enhanced diffusion in SPE regrown silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient, greatly enhanced diffusion has been observed on annealing solid-phase-epitaxial (SPE) grown Si-Sb alloys. This is shown to be due to a high concentration of interstitials being trapped during SPE regrowth. The migration enthalpy, for diffusion of Sb by an interstitialcy mechanism was measured as 1.8 +/- 0.2 eV. The interstitials eventually condensed into loops, marking the end of the transient. In a SPE grown Si-Bi alloy a similar transient enhanced diffusion was observed, with an activation energy of 2.0 +/- 0.2 eV, but no loops formed. 8 figures, 7 references.

1984-01-01

401

Point defect supersaturation and enhanced diffusion in SPE regrown silicon  

International Nuclear Information System (INIS)

Transient, greatly enhanced diffusion has been observed on annealing solid-phase-epitaxial (SPE) grown Si-Sb alloys. This is shown to be due to a high concentration of interstitials being trapped during SPE regrowth. The migration enthalpy, for diffusion of Sb by an interstitialcy mechanism was measured as 1.8 +/- 0.2 eV. The interstitials eventually condensed into loops, marking the end of the transient. In a SPE grown Si-Bi alloy a similar transient enhanced diffusion was observed, with an activation energy of 2.0 +/- 0.2 eV, but no loops formed. 8 figures, 7 references.

402

Investigations for obtaining enhanced SHG element of KH_2PO_4 crystal  

International Nuclear Information System (INIS)

We report investigations of enhancement in material conversion efficiency of KDP for SHG applications. The limitation of conventional technique of growing KDP crystal was overcome in the present work by adopting a growth method to grow KDP directly in type-II phase matching direction. The conventional technique results in #approx#30% of the crystal volume usable for SHG applications whereas the present method has resulted in enhancing it to #approx#90%. The orientation of the element was confirmed by frequency conversion experiment using Nd:YAG laser. The UV-vis transmittance obtained was 92%. The interferometric results show that the crystals have excellent optical homogeneity.

2010-04-01

403

Film condensation of HCFC-22 on horizontal enhanced tubes  

Science.gov (United States)

Experiments were conducted to study the condensation heat transfer characteristics of horizontal enhanced tubes. In the current experiment, six different enhanced tubes, including 26, 40 fpi low fin tubes and four three-dimensional-fin tubes, were tested. The working fluid used in the experiment was HCFC-22. Data were presented in the form of overall heat transfer coefficient at three working pressures, namely 1.32, 1.47 and 1.62 Mpa. In addition, the condensing heat transfer coefficients for the test tubes were obtained from the Wilson plot technique.

1996-01-01

404

Enhancement of the absorption of CO{sub 2} in alkaline buffer solutions: Joint action of two enhancers  

Energy Technology Data Exchange (ETDEWEB)

The authors measured the absorption of CO{sub 2} in alkaline 0.5 M/0.5 M sodium carbonate/bicarbonate buffers containing either saccharose and sodium arsenite or saccharose and formaldehyde. Absorption enhancement increased upon increasing the concentration of either of the catalysts, but the joint action of the two was always less than the sum of their individual effects, the difference being a function of the acidities and concentrations of the catalysts and the pH of the carbonate/bicarbonate buffer solution

1999-05-01

405

Enhanced LMR core cooling utilizing passive vortex devices  

International Nuclear Information System (INIS)

This paper reports several design options for improved passive circulation flow investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.

1988-05-01

406

Enhanced LMR [liquid metal reactors] core cooling utilizing passive vortex devices  

International Nuclear Information System (INIS)

Several design options for improved passive circulation flow have been investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.

1988-05-01

407

Differential diagnosis by CT units with contrast enhancement  

Energy Technology Data Exchange (ETDEWEB)

Variation of CT units, in organs, before and after using contrast enhancing medium was reviewed and personal experience was presented. In the normal brain CT units was little changed by contrast enhancement (CE), whereas remarkable change was observed at lesions. No difference of CT units was observed between the normal liver and hepatomas. The normal kidney had higher CE effect than hypernephromas suggesting an increase of the sensitivity. CE was not found in cysts or necrosis. The changes of CT units in the cases of cerebral diseases are tabled with various contrast medium and scanners.

1981-04-01

408

US Army Self-Development: Enhancer or Barrier to Leader ...  

Science.gov (United States)

... This must be taken a step further in counseling and other feedback and ... Record System Power Point Presentation ,www.armyppt.com/ncoer/6.htm ...

2003-05-01

409

Transport energy efficiency  

International Nuclear Information System (INIS)

Enhancing transport sustainability is the password of national, European, and international policies. The development of innovative solutions is ranging from bio fuels to transport analysis models, materials, traction technologies, mobility management, freight villages.

410

Transhumanism, medical technology and slippery slopes  

UK PubMed Central (United Kingdom)

In this article, transhumanism is considered to be a quasi‐medical ideology that seeks to promote a variety of therapeutic and human‐enhancing aims. Moderate conceptions are distinguished...Full Text Available

2006-09-01

411

Thermodynamics of Multivalent Interactions: Influence of the Linker  

UK PubMed Central (United Kingdom)

This paper describes a thermodynamic analysis of multivalent interactions, with the goal of clarifying the influence of the linker on the enhancement in avidity due to multivalency. The use...Full Text Available

2010-06-01

412

The Development of Enhanced Heat Transfer Condenser ...  

Science.gov (United States)

Page 1. - AERE-' R-7310 THIS DOCUMENT 15 INTENDED FOR PUBLICATION IN THE OPEN LITERATURE. ... Y Page 3. AERE R I 7318 ...

1973-07-01

413

The Changing Face of Urology in 2005  

UK PubMed Central (United Kingdom)

The practice of urology is changing, not only from a medical and technological standpoint, but also from a business standpoint. New and improved computer technology and enhanced databases have allowed...Full Text Available

2004-01-01

415

Summer Opportunities-Teacher Enhancement (NSF 96-89)  

Science.gov (United States)

... exercises and biotechnology labs and didactic material. It includes sessions on computer and media ... computers, and learn how IPT activities and materials can help meet their curriculum objects ...

417

Reducing the Cancer Burden of Lifestyle Factors: Opportunities and Challenges of the Internet  

UK PubMed Central (United Kingdom)

This paper focuses on the Internet as a tool for enhancing behavior and lifestyle changes to reduce the burden of cancer at a population level. The premise of this paper is that the Internet...Full Text Available

418

Prediction of transient-enhanced diffusion during rapid thermal annealing of ion-implanted silicon  

International Nuclear Information System (INIS)

There have been several reports of transient-enhanced diffusion during furnace or rapid thermal annealing of ion-implanted silicon and some reports of no enhancement. In this contribution, the authors show that many of the observed effects can be accounted for by an interstitial trapping mechanism, in which large numbers of Si atoms are trapped by group V dopant atoms in the amorphous material during implantation. These trapped atoms are retained during solid-phase-epitaxial (SPE) growth, but can be released later during thermal processing to give the transient-enhanced diffusion. The authors present a model which can predict the transient effects (or lack of them) for any concentration of Sb, Bi, or As dopants sufficient to amorphize the silicon and any thermal processing technology which relies on SPE growth (furnace, cw laser, or rapid thermal annealing).

1985-03-01

419

Partnerships for Research and Education in Materials (PREM  

Science.gov (United States)

... Materials (PREM) Synopsis of Program: The objective of PREM is to enhance diversity in materials ... careers in materials research. The Partnerships for Research and Education in Materials (PREM ...

420

Partnerships for Research and Education in Materials  

Science.gov (United States)

... Materials (PREM) Synopsis of Program: The objective of PREM is to enhance diversity in materials ... careers in materials research.The Partnerships for Research and Education in Materials (PREM ...

421

PET imaging of tumour hypoxia  

UK PubMed Central (United Kingdom)

Tumour hypoxia represents a significant challenge to the curability of human tumours leading to treatment resistance and enhanced tumour progression. Tumour hypoxia can be detected by non-invasive and...Full Text Available

422

Neurocysticercosis  

UK PubMed Central (United Kingdom)

A single enhancing lesion in the brain parenchyma, also called an inflammatory granuloma, is a frequent neurologic diagnosis. One of the commonest causes of this lesion is human neurocysticercosis,...Full Text Available

2010-08-17

423

Microbial enhanced oil recovery: Entering the log phase  

Energy Technology Data Exchange (ETDEWEB)

Microbial enhanced oil recovery (MEOR) technology has advanced internationally since 1980 from a laboratory-based evaluation of microbial processes to field applications. In order to adequately support the decline in oil production in certain areas, research on cost-effective technologies such as microbial enhanced oil recovery processes must focus on both near-term and long-term applications. Many marginal wells are desperately in need of an inexpensive improved oil recovery technology today that can assist producers in order to prevent their abandonment. Microbial enhanced waterflooding technology has also been shown to be an economically feasible technology in the United States. Complementary environmental research and development will also be required to address any potential environmental impacts of microbial processes. In 1995 at this conference, the goal is to further document and promote microbial processes for ...

1995-12-31

424

Methylisothiazolinone contact allergy and dose-response relationships  

DEFF Research Database (Denmark)

Methylisothiazolinone (MI) used alone is a new preservative causing a high prevalence of contact allergy. The eliciting threshold of MI is unknown. The combination of MI and phenoxyethanol enhances the antimicrobial efficacy of MI.

2011-01-01

425

Magic-angle-spinning NMR studies of acid sites in zeolite H-ZSM-5  

Science.gov (United States)

{sup 1}H, {sup 13}C, {sup 27}Al, and {sup 29}Si magic-angle-spinning (MAS) NMR was used to elucidate the nature of the catalytic activity of zeolite H-ZSM-5. {sup 1}H MAS NMR of sealed samples after mild hydrothermal dealumination shows that the enhanced activity for n-hexane cracking is not due to an enhanced Bronstead acidity. The concentrations of the various OH groups and aluminous species suggest that the reason for the enhanced catalytic activity is the interaction of the n-hexane molecule with a bridging hydroxyl group and with extra-framework aluminium species, which give rise to the enhanced activity, cannot be easily removed from their positions, and are therefore immobilized by the zeolitic framework.

1991-01-01

426

Lipid Peroxidation and Antioxidant Defense ... - LSDA - Experiment  

Science.gov (United States)

Apr 21, 2011 ... The system of lipid peroxidation reacts regularly to adverse effects and results in enhancement of lipid peroxidation and build-up of LPO ...

427

LiF enhanced nucleation of the low temperature microcrystalline silicon prepared by plasma enhanced chemical vapour deposition  

Energy Technology Data Exchange (ETDEWEB)

A 15-nm lithium fluoride (LiF) thin film evaporated on glass substrate is shown to enhance the nucleation of microcrystalline Si grown by plasma enhanced chemical vapour deposition at the amorphous/microcrystalline boundary conditions. The effect is more pronounced at low substrate temperatures, nucleation density being 10 times higher at {approx} 80 {sup o}C. The effect is ascribed to the ionic chemical nature of LiF, the low work function material used in organic electronic devices, and we propose its use for micro patterning crystalline Si regions in otherwise amorphous Si film.

2009-10-30

428

Imaging oxygenation of human tumours  

UK PubMed Central (United Kingdom)

Tumour hypoxia represents a significant challenge to the curability of human tumours leading to treatment resistance and enhanced tumour progression. Tumour hypoxia can be detected by non-invasive and...Full Text Available

2007-04-01

429

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

430

Hypothyroidism Enhances Tumor Invasiveness and Metastasis Development  

UK PubMed Central (United Kingdom)

BackgroundWhereas there is increasing evidence that loss of expression and/or function of the thyroid hormone receptors (TRs) could result in a selective advantage for tumor development,...Full Text Available

431

Examination of Iotophoretic Transport of Ionic Drugs across ...  

Science.gov (United States)

... derived and which describes fundamentally flux enhancement across an artificial membrane or skin: Keywords: Transdermal drug delivery system. ...

1986-07-30

432

Enzymatic engineering of the porcine genome with transposons and recombinases  

UK PubMed Central (United Kingdom)

BackgroundSwine is an important agricultural commodity and biomedical model. Manipulation of the pig genome provides opportunity to improve production efficiency, enhance disease...Full Text Available

433

Enhancing AIS to Improve Whale-Ship Collision Avoidance ...  

Science.gov (United States)

... 2008. Characterizing the relative contributions of large vessels to total ocean noise fields: a case study using the Gerry E. Studds Stellwagen Bank ...

2010-06-01

434

Enhancement of Keratinocyte Differentiation by Rose Absolute Oil  

UK PubMed Central (United Kingdom)

BackgroundThrough differentiation processes, keratinocytes provide a physical barrier to our bodies and control skin features such as moisturization, wrinkles and pigmentation. Keratinocyte...Full Text Available

2010-08-01

435

Enhanced diffusion from interstitial trapping during solid-phase-epitaxial growth of silicon alloys. Draft  

Energy Technology Data Exchange (ETDEWEB)

During the recrystallization by solid-phase-epitaxial (SPE) growth of supersaturated silicon alloys, a high concentration of interstitials is trapped. These are released by subsequent heating causing a transient (greatly enhanced) diffusion of the substitutional dopant by an interstitialcy mechanism. The enhancement may be as much as five orders of magnitude over tracer values, and shows an activation energy of only 1.8 +- 0.2 eV. Following the transient, the interstitials condense into loops, allowing an independent estimate to be made of their concentration. From these observations, we propose that during ion implantation, a fraction of the implanted dopants can acquire their natural valency, and retain it as the crystallization interface passes. For group V dopants this creates the trapped interstitials, giving transient enhanced diffusion when they are released by subsequent annealing.

1984-08-01

436

Enhanced diffusion from interstitial trapping during solid-phase-epitaxial growth of silicon alloys  

Energy Technology Data Exchange (ETDEWEB)

During the recrystallization by solid-phase-expitaxial (SPE) growth of supersaturated silicon alloys, a high concentration of interstitials is trapped. These are released by subsequent heating causing a transient (greatly enhanced) diffusion of the substitutional dopant by an interstitialcy mechanism. The enhancement may be as much as five orders of magnitude over tracer values, and shows an activation energy of only 1.8 +/- 0.2 eV. Following the transient, the interstitials condense into loops, allowing an independent estimate to be made of their concentration. From these observations, it is proposed that during ion implantation, a fraction of the implanted dopants can acquire their natural valency, and retain it as the crystallization interface passes. For group V dopants this creates the trapped interstitials, giving transient enhanced diffusion when they are released by subsequent annealing. 12 references, 6 figures.

1984-01-01

437

Enhanced Reliability MEMS Deformable Mirrors for Space Imaging ...  

Science.gov (United States)

Sep 3, 2010 ... These higher-quality deformable mirrors will enable diffraction-limited performance for many space-based optical systems such as space-based ...

438

Enhanced Algorithms for EO/IR Electronic Stabilization, Clutter ...  

Science.gov (United States)

... coordinates to allow for multisensor fusion, trajectory ... of an image processing toolkit (iPTK ... effectiveness of data-driven registration processing, spatial ...

2009-09-01

439

Enhanced Aircraft Design Capability for the Automated ...  

Science.gov (United States)

... The third series used a correlated parameter covariance matrix derived from a generic database of modeling uncertainty for space structures [5-1 ...

1996-01-31

440

Effect of recoil implantation of oxygen on boron enhanced diffusion in silicon  

International Nuclear Information System (INIS)

In device fabrication, dopants are frequently implanted into silicon through silicon dioxide masks. A consequence of this technique is the co-implantation of recoiled oxygen into the substrate. This study investigates the effect of recoiled oxygen on the widely observed transient enhanced boron diffusion. Comparison of the spreading resistance profiles of annealed through-oxide and directly implanted samples reveals that transient enhanced diffusion of boron can be suppressed by the former process. Continued annealing of the through-oxide implanted silicon recovers the enhanced diffusion of boron. This behavior is believed to be due to precipitation of recoiled oxygen. The mechanisms leading to the above observations are discussed and transmission electron microscopy support presented. 11 refs., 5 figs.

1989-04-25

441

Development Of Very-High-Strength and High-Performance ...  

Science.gov (United States)

... High performance concrete doesn't always refer to enhanced strength, as in the case of VHSC. ... Composite Materials VHSC Concrete ...

2004-12-01

442

Dense and diffuse gas in dynamically active clouds  

CERN Document Server

We investigate the chemical and observational implications of repetitive transient dense core formation in molecular clouds. We allow a transient density fluctuation to form and disperse over a period of 1 Myr, tracing its chemical evolution. We then allow the same gas immediately to undergo further such formation and dispersion cycles. The chemistry of the dense gas in subsequent cycles is similar to that of the first, and a limit cycle is reached quickly (2 - 3 cycles). Enhancement of hydrocarbon abundances during a specific period of evolution is the strongest indicator of previous dynamical history. The molecular content of the diffuse background gas in the molecular cloud is expected to be strongly enhanced by the core formation and dispersion process. Such enhancement may remain for as long as 0.5 Myr. The frequency of repetitive core formation should strongly determine the level of background molecular ...

2006-01-01

443

Cryogenic trick for enhanced cooling using liquid nitrogen  

International Nuclear Information System (INIS)

The thermal transpiration method has been employed to replace the temperature of liquid nitrogen by #approx#12 K. This is done by bubbling He (g) through the liquid nitrogen.

1993-01-01

444

Boron enhanced diffusion due to high energy ion-implantation and its suppression by using RTA process  

Energy Technology Data Exchange (ETDEWEB)

SIMS measurements revealed that high energy boron-implantation causes transient enhanced diffusion (TED) of a shallow dopant profile due to Si interstitials even for a relatively low dose of {approximately}2E13cm{sup {minus}2}. By systematic analysis, it is found that this anomalous diffusion is most significant in 700--800 C annealing, and it takes place in the initial stage (less than 30 sec for 800 C) of annealing. Moreover, this anomalous diffusion is more considerable than the enhanced diffusion during oxidation (OED) in practical device fabrication processes. It is found that rapid thermal annealing (RTA) at 1,000--1,100 C is effective for suppressing the transient enhanced diffusion and realizing a shallow channel profile for deep sub-micron devices.

1995-12-31

445

Boron enhanced diffusion due to high energy ion-implantation and its suppression by using RTA process  

International Nuclear Information System (INIS)

SIMS measurements revealed that high energy boron-implantation causes transient enhanced diffusion (TED) of a shallow dopant profile due to Si interstitials even for a relatively low dose of #approx#2E13cm"-"2. By systematic analysis, it is found that this anomalous diffusion is most significant in 700--800 C annealing, and it takes place in the initial stage (less than 30 sec for 800 C) of annealing. Moreover, this anomalous diffusion is more considerable than the enhanced diffusion during oxidation (OED) in practical device fabrication processes. It is found that rapid thermal annealing (RTA) at 1,000--1,100 C is effective for suppressing the transient enhanced diffusion and realizing a shallow channel profile for deep sub-micron devices.

446

Assessment, development and coordination of technology base studies in enhanced heat transfer. Quarterly progress report No. 7, March 1, 1983-May 31, 1983  

Energy Technology Data Exchange (ETDEWEB)

The major goal of this continuation project is to advance the utilization of heat transfer enhancement techniques in commercial heat exchange equipment. Thirteen heat transfer enhancement techniques have been identified as having potential for improving heat transfer coefficients in full-scale industrial equipment. The following tasks are part of this project, which was originally planned for three years: (1) expansion of technology information base; (2) evaluation of performance of enhanced surfaces and inserts; (3) correlation of data for spirally fluted surfaces; (4) study of structured surfaces in pool boiling; and (5) study of structured surface in spray film evaporation.

1983-08-01

447

Antimicrobial activity and mechanism of action of Nu-3, a protonated modified nucleotide  

UK PubMed Central (United Kingdom)

Background"Nubiotics" are synthetic oligonucleotides and nucleotides with nuclease-resistant backbones, and are fully protonated for enhanced ability to be taken up by bacterial...Full Text Available

448

Absorption of plutonium in the iron-deficient rat  

International Nuclear Information System (INIS)

Iron deficiency did not enhance absorption of plutonium following intragastric gavage of rats. Absorption of plutonium citrate in both control and iron-deficient rats was about 0.03% of the administered dose.

1977-05-01

449

A note on the flow and heat transfer enhancement in a channel with built-in winglet pair  

International Nuclear Information System (INIS)

Counter rotating longitudinal vortices produced by winglet in a channel are known to enhance heat transfer. In the present investigation the flow structure and heat-transfer enhancement by a winglet pair of non-zero thickness has been studied. A delta winglet pair type vortex generator is placed in a hydrodynamically developed and thermally developing laminar channel flow. Computations are done by solving the unsteady, three-dimensional, incompressible Navier-Strokes equations and energy equation using a modified Marker-and-Cell (MAC) method. The flow structure is complex and consists of main, corner and induced vortices. It is observed that as compared to a channel without winglets, the heat transfer is enhanced by 33% when single winglet is used and by 67% when a winglet pair is employed. Effects of thickness of the winglets and Reynolds number on the heat transfer augmentation are presented.

2007-04-01

450

A Cyanobacterial Circadian Clockwork  

UK PubMed Central (United Kingdom)

Cyanobacteria have become a major model system for analyzing clock phenomena. The temporal program in this organism enhances fitness in rhythmic environments and is truly global—essentially...Full Text Available

2008-09-09

451

[Differential diagnosis and prognosis of phobic disorders].  

Science.gov (United States)

The paper presents differential-diagnostic signs of phobic disorders of different etiology. Acute episodes of depersonalization preceding phobias and fears arising during the first age crisis are considered as some diagnostic signs of endogenous phobias. The significant criteria for diagnosis of psychogenic phobias are anxious suspiciousness, affective instability, susceptibility, spontaneity of reactivity and the presence of personally important psychic trauma. An autonomic paroxysm caused by alcoholic situation in exogenic organic pathology (alcoholism) was transformed quite fast into some senestopathias, which themselves maintained the of fear. The relationships of phobias and depressions in endogenous disorders was different: in slow-progredient variations of the disease depression resulted in a decrease of the manifestations of the phobias, and vice versa; in shift-like variations depression is an independent syndrome in the ...

1998-01-01

452

Xeroradiography and computed radiography comparative study on diagnosis for breast cancer  

Energy Technology Data Exchange (ETDEWEB)

Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good ...

1990-04-01

453

Xeroradiography and computed radiography comparative study on diagnosis for breast cancer  

International Nuclear Information System (INIS)

Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good ...

1990-01-01

454

Virtual colonoscopy (CT colonography) in the identification of colorectal cancer. A prospective study in symptomatic patients  

International Nuclear Information System (INIS)

Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher (85.7%) for polyps #>=# 1 cm. Virtual ...

2000-06-01

455

Transient data acquisition techniques under EDS  

Energy Technology Data Exchange (ETDEWEB)

This paper is the first of a series which describes the Enrichment Diagnostic System (EDS) developed for the MARS project at Lawrence Livermore National Laboratory. Although EDS was developed for use on AVLIS, the functional requirements, overall design, and specific techniques are applicable to any experimental data acquisition system involving large quantities of transient data. In particular this paper will discuss the techniques and equipment used to do the data acquisition. Included are what types of hardware are used and how that hardware (CAMAC, digital oscilloscopes) is interfaced to the HP computers. In this discussion the author will address the problems encountered and the solutions used, as well as the performance of the instrument/computer interfaces. The second topic the author will discuss is how the acquired data is associated to graphics and analysis portions of EDS through efficient real time data bases. This discussion will include how the ...

1985-06-01

456

The use of "1"3"1I-radioiodine in diagnostic and treatment: estimated risk in Guanabara  

International Nuclear Information System (INIS)

The "1"3"1-radioiodine use in Guanabara area, during 1972-1973, is analysed. References are made to the radiation levels delivered to thyroid, bone marrow and gonads in a population of 27000 people examined by tracer techniques, 190 submitted to hyperthyroidism treatment and 50 treated for thyroid cancer. The pertinent literature gives some data concerning radiation induced cancer (leukaemia and thyroid cancer). By this, it was possible to estimate the probability of tumour occurrence in that population, assuming a linear relationship between dose and effect. The conclusions are the followings: 1 - there are many duties in this field at the present; 2 - the leukaemia incidence related to the 131-radioiodine use is negligible, either in diagnostic or therapeutic modalities; 3 - the possibility of thyroid tumors induced by radiation is real, specially in hyperthyroidism treatment; 4 - the use of tracer techniques that cause lower irradiation to the pacient is ...

457

The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose  

International Nuclear Information System (INIS)

The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies establishing a somatically significant dose, SSD. The reduction ...

1991-11-01

458

The Kinematic Signature of Face-On Peanut-Shaped Bulges  

CERN Document Server

We present a kinematic diagnostic for peanut-shaped bulges in nearly face-on galaxies. The face-on view provides a novel perspective on peanuts which would allow study of their relation to bars and disks in greater detail than hitherto possible. The diagnostic is based on the fact that peanut shapes are associated with a flat density distribution in the vertical direction. We show that the kinematic signature corresponding to such a distribution is a minimum in the fourth-order Gauss-Hermite moment $s_4$. We demonstrate our method on $N$-body simulations of varying peanut strength, showing that strong peanuts can be recognized to inclinations $i \\simeq 30\\degrees$, regardless of the strength of the bar. We also consider compound systems in which a bulge is present in the initial conditions as may happen if bulges form at high redshift through mergers. We show that in this case, because the vertical structure of the bulge is not derived from ...

2005-01-01

459

Steady-state passive films; Interfacial kinetic effects and diagnostic criteria  

Energy Technology Data Exchange (ETDEWEB)

This paper reports that the point defect model for steady-state passive films formed anodically on metal s in aqueous environments has been extended to include irreversible dissolution of the film and the irreversible generation and annihilation of cation and oxygen vacancies at the metal/film and film/solution interfaces. THe model yields a number of diagnostic criteria that can be used to identify the majority (vacancy) charge carrier and to characterize the kinetic nature of the interfacial vacancy generation and annihilation processes. We use these criteria to show that the steady-state passive film that forms on nickel in acidic phosphate buffer solutions is a cation conductor and that cation transport from the metal to the solution involves irreversible ejection of cations from the film. On the other hand, the passive film that forms on tungsten in the same environment under steady-state conditions is found to be an oxygen ion conductor with the passive ...

1992-01-01

460

Pelvic CT for the prognostic evaluation of anorectal malformation  

International Nuclear Information System (INIS)

The anatomical patterns of anorectal malformations have so far been studied according to the principles which inspire Pena's technique for the surgical treatment of anorectal anomalies. Thus, the diagnostic study of anorectal malformation has by the authors been considered a work of classification, but of identification. Among the diagnostic procedures in use in author's Institute, preoperative CT of pelvis is performed to assess the presence and to define the development of muscular sphincteric structure towards prognostic evaluation of continence, the major long-term goal. Seven patients, aged 1-30 months, with anorectal anomalies were studied with preoperative CT of the pelvis. CT scans showed well-developed sphinteric muscles in 3 patients (2 with recto-ureteral and 1 with recto-vestibular fistulas), poorly-developed muscular structure in 3 patients (with recto-vaginal, cloacal and prostatic fistulas), absence of muscular structure in 1 ...

1989-01-01

461

Need for New Optimisation Strategies in CR and Direct Digital Radiography  

Energy Technology Data Exchange (ETDEWEB)

Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a definition of reference ...

2000-07-01

462

Need for New Optimisation Strategies in CR and Direct Digital Radiography  

International Nuclear Information System (INIS)

Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a definition of reference ...

1999-06-13

463

MRI of congenital heart disease in childhood  

International Nuclear Information System (INIS)

MRI provides a non-invasive diagnostic tool complementing echocardiography on one hand, and showing advantages over echocardiography, on the other hand, especially after corrective procedures. The multiple different MRI sequences need to be adapted to examinations of children and patients with congenital heart disease (CHD), and can be used to detect morphologic changes, blood-flow in the heart and thoracic vessels and diastolic or systolic function of myocardium. Several factors determine the success of the examination of a complex congenital heart disease or a postoperative situs. Pediatric radiologists and radiologists experienced in congenital heart diseases have to work in close cooperation. Echocardiography should be performed before MRI. The results of prior examinations and the clinical history of the patients, including possible palliative or reconstructive operations, must be available before MRI to guide the planning of the examination. With a systematic ...

2004-02-01

464

Locally Optimally-emitting Clouds and the Narrow Emission Lines in Seyfert Galaxies  

CERN Document Server

The narrow emission line spectra of active galactic nuclei are not accurately described by simple photoionization models of single clouds. Recent Hubble Space Telescope images of Seyfert 2 galaxies show that these objects are rich with ionization cones, knots, filaments, and strands of ionized gas. Here we extend to the narrow line region the ``locally optimally emitting cloud'' (LOC) model, in which the observed spectra are predominantly determined by powerful selection effects. We present a large grid of photoionization models covering a wide range of physical conditions and show the optimal conditions for producing many of the strongest emission lines. We show that the integrated narrow line spectrum can be predicted by an integration of an ensemble of clouds, and we present these results in the form of diagnostic line ratio diagrams making comparisons with observations. We also predict key diagnostic line ratios as a function of distance ...

1997-01-01

465

Handbook on diagnostic radiology. Muscels and skeleton 2; Handbuch diagnostische Radiologie. Muskuloskelettales System 2  

Energy Technology Data Exchange (ETDEWEB)

The second volume contains a comprehensive presentation of inflammatory bone diseases, including seldom primary chronic osteomyelitis and morbus Paget. Substantial chapters on bone tumors and tumor-like lesions of bone joints are covering the state-of-the-art of diagnostic techniques of these seldom but important diseases. Besides the importance of projection radiography the contribution of MRI within differential diagnosis und staging of these diseases is emphasized. [German] Der zweite Band des Muskuloskelettalen Systems befasst sich mit der umfassenden Darstellung zur Diagnostik entzuendlicher Knochenerkrankungen und beinhaltet neben den klassischen infektioesen auch die seltenen, primaer chronischen Osteomyelitiden und den Morbus Paget. Umfangreiche Kapitel ueber die Knochentumoren und tumoraehnlichen Laesionen der Gelenke stellen in modernster Weise den aktuellen Stand des Wissens und der Diagnostik dieser seltenen, aber aus differenzialdiagnostischer Sicht ...

2005-07-01

466

Fast diagnosis and treatment of crack-like defect injuriousness in nuclear power plant equipment  

Energy Technology Data Exchange (ETDEWEB)

Increasingly stringent safety requirements governing the nuclear industry have made it essential to gain in-depth knowledge of the injuriousness of cracking phenomena in auxiliary and secondary nuclear power plant systems, and to devise methods of rapidly evaluating potentially injurious flaws. The Defect Injuriousness Diagnosis and Treatment Package (DIDTP) discussed in this paper was developed by Framatome, a French-based PWR builder, with this goal in mind. A general description is given of the DIDTP, which is made up of tables and nomographs illustrating the injuriousness of flaws liable to be encountered in the most severely loaded regions of plant systems. The basic principles underlying the DIDTP, together with computational methods and application procedure, are detailed. Two practical examples illustrating the use of the diagnostic system are presented, one applied to the main steam line, the other to gate valve wedges. The types of results obtained and ...

1985-01-01

467

Equation of state of laser-shocked compressed iron; Equation d'etat du fer comprime par choc laser  

Energy Technology Data Exchange (ETDEWEB)

This thesis enters the field of highly compressed materials equation of state studies. In particular, it focuses on the case of laser shock compressed iron. This work indeed aims at getting to the conditions of the earth's core, comprising a solid inner core and a liquid outer core. The understanding of phenomena governing the core's thermodynamics and the geodynamic process requires the knowledge of iron melting line locus around the solid-liquid interface at 3.3 Mbar. Several experiments were performed to that extent. First, an absolute measurement of iron Hugoniot was obtained. Following is a study of partially released states of iron into a window material: lithium fluoride (LiF). This configuration enables direct access to compressed iron optical properties such as reflectivity and self-emission. Interface velocity measurement is dominated by compressed LiF optical properties and is used as a pressure gauge. Using a dual wavelength reflectivity ...

2004-01-01

468

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants; Traitement des signaux de courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostics system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1991-07-01

469

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants. Traitement des signaux courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

470

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive lines'. In one case of aseptic loosening ...

471

Diagnostic imaging and interventional radiology of the amoebic liver abscess. Personal experience; Diagnostica per immagini e radiologia interventistica degli ascessi amebici del fegato: esperienza personale  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.

1999-10-01

472

Diagnostic difficulties in extraosseous Ewing's sarcoma: A proposal for diagnostic criteria  

International Nuclear Information System (INIS)

Five cases diagnosed as extraosseous Ewing's sarcoma (EES) during a 15 year period, and the relevant literature, were reviewed. The diagnosis in these cases was difficult to confirm, mainly because the distinction between the osseous form of Ewing's sarcoma (OES) and either periosteal reactions or direct tumour invasion into adjacent bone by EES was often unclear. The literature suggests that other authors have also encountered difficulties. The authors believe that many cases reported as EES are likely to have been OES. This distinction has some importance, as the two conditions are usually treated in differing ways. The following criteria are proposed for the diagnosis of primary EES: (i) no evidence of bony involvement on magnetic resonance imaging; (ii) no evidence of increased uptake in bone or periosteum adjacent to the tumour on static isotope bone scan images; (iii) a small round cell tumour with no differentiating features on light microscopy, immunochemistry or electron ...

473

Computer assisted axial tomography (Emi scan) in neurologic investigation  

Science.gov (United States)

Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of ...

1974-01-01

474

Computed tomography of the thorax: a status report  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal lymph nodes in ...

1981-11-01

475

Computed tomography of the thorax: a status report  

International Nuclear Information System (INIS)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal lymph nodes in ...

476

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...

1981-01-01

477

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of simultaneous ...

1987-12-01

478

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of simultaneous ...

1987-01-01

479

Adaptation of a cubic smoothing spline algortihm for multi-channel data stitching at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Some diagnostics at the National Ignition Facility (NIF), including the Gamma Reaction History (GRH) diagnostic, require multiple channels of data to achieve the required dynamic range. These channels need to be stitched together into a single time series, and they may have non-uniform and redundant time samples. We chose to apply the popular cubic smoothing spline technique to our stitching problem because we needed a general non-parametric method. We adapted one of the algorithms in the literature, by Hutchinson and deHoog, to our needs. The modified algorithm and the resulting code perform a cubic smoothing spline fit to multiple data channels with redundant time samples and missing data points. The data channels can have different, time-varying, zero-mean white noise characteristics. The method we employ automatically determines an optimal smoothing level by minimizing the Generalized Cross Validation (GCV) score. In order to automatically ...

2010-12-28

480

Treatment of multi-ruptured complex pseudoaneurysm with injection of fibrin sealant into lumens: report of one case with literature review  

International Nuclear Information System (INIS)

This paper is to report a case of multi-ruptured complex pseudoaneurysm confirmed by three-dimensional DSA. Under three-dimensional DSA guidance, the thrombin was injected into lumens in the attempt to cure the pseudoaneurysm. As the result was unsatisfactory, fibrin sealant was used to inject into the lumens again, and good curative effect was obtained. In clinical interventional practice, the incidence of pseudoaneurysm has been steadily increasing and the lesions have become more and more complex. In this paper the authors have discussed the diagnostic and therapeutic methods of complex pseudoaneurysm in order to provide clinical physicians with useful information. (authors)

2009-03-01

481

The value of computed tomography in the diagnosis of grating scapula  

Energy Technology Data Exchange (ETDEWEB)

Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)

1994-07-01

482

Technetium complexes as potential brain imaging agents  

International Nuclear Information System (INIS)

Single photon tomography using lipophilic tracers provides tomographic representations of regional blood flow. To penetrate a healthy blood-brain barrier requires that radiotracers either are fat-soluble or have an affinity for one of the selective blood-brain barrier transport systems. In recent years there has been an increasing interest to explore the ideal physical characteristics of "9"9"mTc for diagnostic problems of brain diseases. The development of radiopharmaceuticals for brain imaging including the intensively studied "9"9"mTc-propyleneamineoxime derivatives is discussed. (author).

483

Seismic and Rockphysics Diagnostics fo Multiscale Reservoir Textures  

Energy Technology Data Exchange (ETDEWEB)

We have continued to finish up our work on analyzing relationships between elastic properties and rock microstructure. We have worked on theoretical models for the effects of sorting and packing on elastic moduli and seismic velocities. After analyzing the scanning acoustic images of shales to quantify textures at different scales, we are now using theoretical inclusion models to quantify the elastic property variation with texture. In the closing phases of this project most of our efforts are now focused on writing up the results and preparing the final reports.

2005-02-01

484

Picosecond timing of terawatt laser pulses with the SLAC 46 GeV electron beam  

International Nuclear Information System (INIS)

We report on the collision of 1.5 ps (FWHM) laser pulses traversing at 17 a short similar 7 ps (FWHM) 46.6 GeV electron bunch. The phase-locked system used to maintain the correct timing of the laser pulses and the appropriate diagnostics are described. The jitter between the laser and electron pulses is determined from the stability of the observed rate of Compton scatters and can be described by a Gaussian distribution with #sigma#_j#approx =#2.2 ps. (orig.).

485

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

486

Light elements in massive single and binary stars  

CERN Document Server

We highlight the role of the light elements (Li, Be, B) in the evolution of massive single and binary stars, which is largely restricted to a diagnostic value, and foremost so for the element boron. However, we show that the boron surface abundance in massive early type stars contains key information about their foregoing evolution which is not obtainable otherwise. In particular, it allows to constrain internal mixing processes and potential previous mass transfer event for binary stars (even if the companion has disappeared). It may also help solving the mystery of the slowly rotating nitrogen-rich massive main sequence stars.

2010-01-01

487

Interview: Trevor Keel from the World Gold Council  

British Library Electronic Table of Contents (United Kingdom)

Trevor Keel speaks to Cara Sutton, Assistant Commissioning Editor Within the World Gold Council's technology sector, Trevor Keel is responsible for a range of activities in relation to the development of new gold-based technologies. He has particular interest in the use of gold in the fields of medicine and diagnostics, catalysis and nanotechnology. Previously, Trevor was a principal chemist at GlaxoSmithKline where he was involved in numerous New Chemical Entity projects. Dr Keel has an extensive knowledge of nanotechnology, having completed a PhD in Pharmaceutical Nanotechnology at the University of Nottingham, Nottingham, UK.

2011-01-01

488

International trends in radiation protection  

International Nuclear Information System (INIS)

The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.

489

Gross anatomy of network security  

Science.gov (United States)

Information security involves many branches of effort, including information assurance, host level security, physical security, and network security. Computer network security methods and implementations are given a top-down description to permit a medically focused audience to anchor this information to their daily practice. The depth of detail of network functionality and security measures, like that of the study of human anatomy, can be highly involved. Presented at the level of major gross anatomical systems, this paper will focus on network backbone implementation and perimeter defenses, then diagnostic tools, and finally the user practices (the human element). Physical security measures, though significant, have been defined as beyond the scope of this presentation.

2002-01-01

490

Gaseous dielectrics V  

Energy Technology Data Exchange (ETDEWEB)

This book discusses the progress and problems of current interest in gaseous dielectrics and their use, with special emphasis on insulation in high-voltage transmission lines and substations. Topics covered include: basic physics of gaseous dielectrics; basic mechanisms; gas decomposition, reactions and toxicity; diagnostics and field probes; gases and mixtures for GIS transformers and circuit breakers; gaseous media for discharge chemistry and etching/corona; gas engineering for pulsed power and switching; gas breakdown under steep-fronted voltages; new developments in gas-insulated equipment and gas handling; gas/insulator interface/flashover; and quality control in testing gas-insulated equipment. Contains approximately 85 papers.

1987-01-01

491

Fabrication of the 320-CM-OD all-ceramic ZT-40 torus  

International Nuclear Information System (INIS)

The fabrication of the ZT-40 torus, a large complex all-ceramic toroidal plasma containment vessel, is described. Several glass sealants covering the temperature range of 500 to 1300"0C, were developed and used to ''braze'' segments of the torus together, sapphire windows to the torus and the required pump-out and diagnostic parts to the ceramic vacuum vessel. Designs of window seals were developed that allowed sealing of the sapphire windows in a vertical position with minimum sealing glass flow.

492

Extraction methods of multi-fault information in machine condition monitoring  

Energy Technology Data Exchange (ETDEWEB)

An outline of the multi-fault diagnostic observation concept is presented in the paper. Starting from the commonly used singular value decomposition (SVD) it is shown, that it is equivalent to the modern version of principal component analysis (PCA). During the development of the concept of multi-fault observation several indices and measures obtained from SVD were tried, and some seem to bring the success. This problem is also addressed in the paper and illustrated by real examples taken from railroad Diesel engine condition monitoring. (orig.)

2003-07-01

493

Cutaneous leishmaniasis associated with jungle training.  

Science.gov (United States)

In November 1977, 627 soldiers belonging primarily to the First Battalion, 82nd Airborne Division, stationed at Fort Bragg, were sent to the Canal Zone, Panama, for jungle warfare training. A medical surveillance program incorporating pre- and post-evaluations over a 6-month period with dermatologic examinations, questionnaires, and serologic tests was established. Ten cases of cutaneous leishmaniasis (1.6/100 men) were diagnosed by positive Leishmania culture. The demonstrated lack of sensitivity and specificity of the indirect fluorescent antibody test and the direct agglutination test render these serological methods useless as diagnostic screening methods in the early stages of this disease. PMID:7406101

1980-07-01

494

Confocal Imaging of Biological Tissues Using Second Harmonic Generation  

Energy Technology Data Exchange (ETDEWEB)

A confocal microscopy imaging system was devised to selectively detect Second harmonic signals generated by biological tissues. Several types of biological tissues were examined using this imaging system, including human teeth, bovine blood vessels, and chicken skin. All these tissues generated strong second harmonic signals. There is considerable evidence that the source of these signals in tissue is collagen. Collagen, the predominant component of most tissues, is known to have second order nonlinear susceptibility. This technique may have diagnostic usefulness in pathophysiological conditions characterized by changes in collagen structure including malignant transformation of nevi, progression of diabetic complications, and abnormalities in wound healing.

2000-03-06

495

Analysis of brain CT on 120 patients of human cysticercosis  

International Nuclear Information System (INIS)

A study on brain CT was made in 120 patients of human cysticercosis, which is a rare disease in Japan and clinical symptoms and laboratory data for the diagnosis were also discussed. From the point of therapeutic view, we proposed a new differentiation on brain CT of human cysticercosis, which is divided into two groups according to the alve or dead parasite. Furthermore, we proposed a new type named multiple large and small cysts type on brain CT. The idea of diagnostic standard was made integrating brain CT image, clinical symptoms and labolatory data. (author).

496

Adrenocortical (dys)function in septic shock - A sick euadrenal state  

British Library Electronic Table of Contents (United Kingdom)

A central feature of the endocrine pathophysiology of septic shock is thought to be the existence of adrenal dysfunction. Based on changes in glucocorticoid secretion and responsiveness, protein binding, and activity. These changes have been described by the terms "Relative Adrenal Insufficiency" (RAI), or "Critical Illness Related Corticosteroid Insufficiency" (CIRCI), and form part of the rationale for trials of glucocorticoid treatment in septic shock. Diagnostic criteria for these conditions have been based on plasma cortisol profiles and have proven notoriously difficult to establish. The uncertainty in this area arises from the inability of current tests to clearly identify who is truly glucocorticoid "deficient" at a cellular level, and hence who requires supplemental glucocorticoid...

2011-01-01

497

A neuro-fuzzy technique for fault diagnosis and its application to rotating machinery  

Energy Technology Data Exchange (ETDEWEB)

Malfunctions in machinery are often sources of reduced productivity and increased maintenance costs in various industrial applications. For this reason, machine condition monitoring is being pursued to recognise incipient faults. In this paper, the fault diagnostic problem is tackled within a neuro-fuzzy approach to pattern classification. Besides the primary purpose of a high rate of correct classification, the proposed neuro-fuzzy approach also aims at obtaining an easily interpretable classification model. The efficiency of the approach is verified with respect to a literature problem and then applied to a case of motor bearing fault classification.

2009-01-15