Measurement of energy expenditure in overweight men and women using [C-14]-bicarbonate-urea before and after weight loss  

International Nuclear Information System (INIS)

Full text: Many studies have demonstrated significant declines in 24-hour energy expenditure (TEE) measured by whole body calorimetry with either the process of weight loss or the maintenance of reduced body weight. The aims of this study were to determine the effect of weight loss and two weeks of weight maintenance on TEE using ["1"4C]-bicarbonate-urea, Eleven subjects (6 males, 5 females), mean (#+-#SE) age 50 #+-# 3 years, BMI 34.1 #+-# 2.1 kg/m2 and body fat 38.7 #+-# 3% were studied before and after a decrease in body weight of > 8% over a period of 8 weeks, followed by two weeks of weight maintenance. Weight loss was induced using the combination of Modifast and one small meal a day (#approx#3.34 MJ/day). Body composition (DEXA), resting energy expenditure (REE) and the thermic effect of a 2.7 MJ test meal (TEF) were measured in addition to TEE at week 2 and again at week 12. Diet was assessed using diaries and ...

2002-05-04

2

LES benchmark study of high cycle temperature fluctuations caused by thermal striping in a mixing tee  

Energy Technology Data Exchange (ETDEWEB)

Thermal striping is identified as one of the causes of thermal fatigue failure in nuclear power plants. Numerical studies of thermal striping require three-dimensional, unsteady turbulent modeling that resolves both large and small-scale turbulent motions. Benchmark studies were carried out using the LES turbulence model solved by the commercial CFD code FLUENT. Two types of mixing tee configurations were modeled to evaluate the performance of the CFD code. The simulation results presented in normalized average temperature and normalized fluctuating temperatures are in good agreement with measurements.

2006-02-15

3

Contribution to the compensation of extra high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

An improved method to design suitable compensating schemes for extra high voltage transmission lines is presented. The technique is general and effective and will greatly facilitate the design of the optimal compensation scheme for extra high voltage transmission lines. The technique is illustrated for a typical 500 kV system. The equations developed here for voltage maxima and minima along the transmission line eliminate the need for point-to-point computation of the voltage profile. The controversy existing in the literature over the problem of making a choice between pi and tee configurations has been removed and it is established with a mathematical proof that the tee configuration requires compensating elements of lower ratings.

1987-04-01

4

Dietary energy requirements of young adult men, determined by using the doubly labeled water method  

International Nuclear Information System (INIS)

The autors examined the hypothesis that current recommendations on dietary energy requirements may underestimate the total energy needs of young adult men, by measuring total energy expenditure (TEE) and resting energy expenditure (REE) in 14 weight-maintaining healthy subjects leading unrestricted lives. TEE and body composition were measured by using 2H(2)18O, and REE was measured by using indirect calorimetry. All subjects had sedentary full-time occupations and participated in strenuous leisure activities for 34 #+-# 6 (SE) min/d. TEE and REE were 14.61 #+-# 0.76 and 7.39 #+-# 0.26 MJ/d, respectively, and 202 #+-# 2 and 122 #+-# 2 kJ.kg-1.d-1. There were significant relationships between TEE and both body fat-free mass (r = 0.732, P less than 0.005) and measured REE (r = 0.568, P less than 0.05). Measured TEE:REE values were significantly higher than the recommended energy ...

5

Sinus Surgery  

Medline Plus

... know if the drainage becomes very clear, like tap water. This may be the first indication that there ...

6

Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement  

British Library Electronic Table of Contents (United Kingdom)

BackgroundEchocardiography has been debated as an adjunct for transcatheter aortic valve replacement (TAVR). The aim of this prospective study was to comparatively evaluate intraprocedural guidance using intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE). MethodsFifty high-risk patients with severe aortic stenosis scheduled for TAVR were randomized to either guidance using ICE (group 1; n = 25) or monitoring using TEE (group 2; n = 25). ResultsIn contrast to TEE, ICE allowed continuous monitoring. The need for probe repositioning during the procedure was much lower in group 1 (0.1 +- 0.3 vs 5.7 +- 0.7 maneuvers, P P = .003). Both coronary ostia were more frequently visualized in group 1 (18 vs 2 cases, P n = 25, r2 = 0.90, P n = 11, P = .012), but ICE did not (m...

2011-01-01

7

Distribution of activation energies for impurity hopping in amorphous metals  

Energy Technology Data Exchange (ETDEWEB)

The distribution of activation energies ..delta.. for classical over-the-barrier hopping is computed for a model amorphous metal. The spread in ..delta.. is determined by the variation in equilibrium-site and saddle-point sizes for the assumed model of dense random packing (DRP) of soft spheres. The size distribution is related to the radial distribution function in a manner which reproduces recent numerical results for the interstitials in DRP models. Size (distance) variation in general is related to energy variation by the form of the potential energy V(r). We show, however, that the distribution of equilibrium-site energies can be related directly to the impurity-induced lattice expansion and bulk modulus without detailed knowledge of V(r). The form of V(r) is necessary for the saddle-point distribution, and we estimate this using simple analytic expressions which fit the observed lattice expansion and impurity (hydrogen) vibrational ...

1983-02-15

8

Transesophageal echo to help percutaneous closure of ventricular septal defect post acute myocardial infarction  

British Library Electronic Table of Contents (United Kingdom)

Ventricular septal defect after acute myocardial infarction (AMI) is a complication associated with poor outcome in the absence of intervention. We report a case of successful TEE guided transcatheter closure of a post myocardial infarction (MI) ventricular septal defect (VSD) with an Amplatzer occluder in a 79 years old male with cardiogenic shock.

2011-01-01

9

Prevent Diabetes Problems: Keep Your Heart and Blood Vessels Healthy  

Science.gov (United States)

... mini-stroke," also called a TIA or a transient ischemic attack . If you have any of these warning signs, ... ur-uhl) (ar-TEE-ree-uhl) (dih-ZEEZ) transient ischemic attack (TRANZ-see-uhnt) (iss-KEE-mik) (uh-TAK) [ ...

10

Corrosion of Cu-W condensates in tap water  

International Nuclear Information System (INIS)

Corrosion resistance of Cu-W system condensates in tap water was studies. It is shown that with an increase in W concentration in the condensates of the Cu-W system their corrosion in tap water enhances. In the material designated for power supply facilities the optimal tungsten content is up to 6%. Owing to formation of oxide film on the surface of the samples corrosion is stabilitized 40 h after the test start.

11

Energy saving self-powered industrial dehumidifier  

Energy Technology Data Exchange (ETDEWEB)

An energy saving self-powered industrial dehumidifier for use in a building having a tap water conduit leading from a source of supply to utilization points is described comprising: a dehumidifying apparatus positioned in a stream of air to be dehumidified in the building. The dehumidifying apparatus comprising conduit means for diverting at least a portion of a relatively continuously moving stream of tap water from the tap water conduit through a heat exchanger positioned in a stream of air and returning the diverted portion to the tap water stream upstream of the utilization points. Water vapor in the stream of air will condense onto the heat exchanger when the tap water has a temperature below a dew point temperature of the air stream, thereby dehumidifying the air stream.

1988-07-26

12

Explosions of chaotic sets  

Science.gov (United States)

Large-scale invariant sets such as chaotic attractors undergo bifurcations as a parameter is varied. These bifurcations include sudden changes in the size and/or type of the set. An explosion is a bifurcation in which new recurrent points suddenly appear at a non-zero distance from any pre-existing recurrent points. We discuss the following. In a generic one-parameter family of dissipative invertible maps of the plane there are only four known mechanisms through which an explosion can occur: (1) a saddle-node bifurcation isolated from other recurrent points, (2) a saddle-node bifurcation embedded in the set of recurrent points, (3) outer homoclinic tangencies, and (4) outer heteroclinic tangencies. (The term ``outer tangency'' refers to a particular configuration of the stable and unstable manifolds at tangency.) In particular, we examine different types of tangencies of stable and unstable manifolds from orbits of pre-existing invariant sets. ...

2000-09-01

13

Effect of treatment time on low temperature plasma nitriding of stainless steel by saddle field neutral fast atom beam source  

International Nuclear Information System (INIS)

Recent research carried out in laboratories showed that Saddle field neutral fast atom beam source is a promising method for nitriding of stainless steel. In the present work, the effect of treatment time on the microstructural and mechanical properties of plasma-nitrided stainless steel sample was investigated by this new method. Plasma nitriding was carried out at 420 deg. C and at a pressure of 0.1 Pa for a time range of 1 to 12 h. SEM-EDX, microhardness tests, optical microscopy and X-ray diffraction (XRD) were used to evaluate the mechanical and structural properties of the nitrided layer. It was found that nitriding time has a pronounced effect on the structural and mechanical properties of low-temperature plasma-nitrided samples and produced a precipitation-free thin hard nitrided layer within a short processing time.

2006-09-25

14

Radiostrontium in milk and tap water. Appendix D  

International Nuclear Information System (INIS)

Results of monitoring milk and tap water in New York City are presented. The New York City sample is a monthly composite of pasteurized milk purchased daily at retail stores. The monthly "9"0Sr to calcium ratios for New York City since the inception of the sampling program in 1954 are presented. Samples of New York City tap water are taken daily, so that by the end of the month, approximately 100 liters have been collected. The available cesium-137 data expressed as the "1"3"7Cs to "9"0Sr ratio are also given.

1980-01-01

15

Chris Kemp is Named NASA CTO for IT  

Science.gov (United States)

Jun 23, 2010 ... Recently, NASA CIO Linda Cureton tapped Chris Kemp as the Agency's new Chief Technology Officer for IT. In this new capacity, he will work ...

16

China Report, Economic Affairs  

Science.gov (United States)

... increasing its economic results, tapping mew financial sources and augmenting its income, but also a basic task in financial and tax management. ...

1986-04-09

17

Fouling Study of Silicon Oxide Pores Exposed to Tap Water  

Energy Technology Data Exchange (ETDEWEB)

We report on the fouling of Focused Ion Beam (FIB)-fabricated silicon oxide nanopores after exposure to tap water for two weeks. Pore clogging was monitored by Scanning Electron Microscopy (SEM) on both bare silicon oxide and chemically functionalized nanopores. While fouling occurred on hydrophilic silicon oxide pore walls, the hydrophobic nature of alkane chains prevented clogging on the chemically functionalized pore walls. These results have implications for nanopore sensing platform design.

2007-07-12

18

Assessment of internal contamination due to gamma emitters at nuclear power stations of Tarapur  

International Nuclear Information System (INIS)

Personal monitoring and dose assessment of all radiation workers is an essential regulatory requirement as per radiation safety procedures of AERB and operating stations. The occupational workers of TAPS 1 and 2 and TAPS 3 and 4 are monitored for internal contamination due to high energy gamma emitters by whole body counting

2010-02-03

19

Microprocessor-controlled anodic stripping voltammeter for trace metal analysis in tap water  

Energy Technology Data Exchange (ETDEWEB)

The construction and use of a portable, microprocessor controlled anodic stripping voltameter for on-site simultaneous metal analysis of copper, lead and cadmium in tap water is discussed. The instrumental system is comprised of a programmable controller which permits keying in analytical parameters such as sparge time and plating time: a rotating cell for efficient oxygen removal and amalgam formation; and, data handling via a minicomputer or analog pen recorder. Plating and stripping potentials are controlled by a digital potentiostat; stripping is done using a staircase waveform with measurement of the current after a one msec delay. In this way charging current effects are minimized. Results of tap water analysis showed 3 +- 1 ..mu..g/L lead, 22 +- 0.3 ..mu..g/L copper, and less than 0.2 ..mu..g/L cadmium for a Berkeley, California tap water, and 1-1000 ..mu..g/L Cu, 1 -2 ..mu..g/L Pb for ten samples of Seattle, ...

1984-06-01

20

Ultrashort echo time MRI of cortical bone at 7 tesla field strength: A feasibility study  

British Library Electronic Table of Contents (United Kingdom)

AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...

2011-01-01

 
 
 
 
21

Homoclinic chaos in the dynamics of a general Bianchi type-IX model  

International Nuclear Information System (INIS)

The dynamics of a general Bianchi type-IX model with three scale factors is examined. The matter content of the model is assumed to be comoving dust plus a positive cosmological constant. The model presents a critical point of saddle-center-center type in the finite region of phase space. This critical point engenders in the phase space dynamics the topology of stable and unstable four dimensional tubes RxS"3, where R is a saddle direction and S"3 is the manifold of unstable periodic orbits in the center-center sector. A general characteristic of the dynamical flow is an oscillatory mode about orbits of an invariant plane of the dynamics which contains the critical point and a Friedmann-Robertson-Walker (FRW) singularity. We show that a pair of tubes (one stable, one unstable) emerging from the neighborhood of the critical point towards the FRW singularity have homoclinic transversal crossings. The homoclinic intersection manifold has topology ...

2002-04-15

22

Low-energy fission of nuclei lighter than Hg  

International Nuclear Information System (INIS)

The mass and energy distributions for low-energy p- and alpha-particle induced fission of "1"8"7","1"8"8Ir and "1"9"5Au and "3He-induced fission of sufficiently heated "1"8"8Ir and "1"9"4Au have been measured with use of fast spectrometer of complementary fragments. From Au to Ir, the shape of the mass distributions undergoes substantial changes related to specific dependence of the saddle shell corrections on A and Z fissioning nuclei. The results are compared with theoretical predictions.

23

Pipework design and operation  

Energy Technology Data Exchange (ETDEWEB)

This book presents the proceedings of a conference dedicated to the design and operation of pipework in all its aspects, involving both metallic and non-metallic materials. Topics considered include a study of single mitre pipe bends using the finite element method; tests to failure of GRP pipe bends under in-plane flexural loading; finite element stress analysis of an equal diameter branch pipe intersection subjected to internal pressure and in-plane moment loadings; finite element stress analysis of extruded outlet tee junctions; design of pipework on the British PWR; a review of advanced remanent life methods for pipes operating in the creep range; pipe whip analysis and design; damping values for piping systems; pipework snubbers based on electro-rheological fluids; and the seismic design of piping systems in the flexible range.

1985-01-01

24

Measurement of induced radioactivity in materials found around a neutron generator  

Science.gov (United States)

The induced radioactivity in the construction materials of a Cockcroft-- Walton type neutron generator was measured. Major activation products (/sup 24/ Na, /sup 28/Al, /sup 56/Mn, /sup 64/Cu, /sup 65/Ni, /sup 69m/Zn, /sup 88/Rb /sup 91/Sr /sup 101/Mo, /sup 187/W/ and resulting doses are tabulated. Results show that the highest gamma activities would be observed in the fluorescent bulbs, copper pipe, aluminum lattice rod, and the aluminum pipe clamp. Thermoluminescent dosimeter readings yield the highest doses for the copper pipe tee, copper pipe, and aluminum lattice rod. Results of measuremerts of the neutron and gamma dose profiles of the facility are shown. However the indication is clearly that the tritium target, compared to other components, is the major source of radiation both during and after shutdown. (UK)

1974-01-01

25

Exhaust-catalyst development for methanol-fueled vehicles. 3. Formaldehyde oxidation  

Energy Technology Data Exchange (ETDEWEB)

Formaldehyde oxidation was examined in a laboratory reactor over alumina-supported Pt, Pd, Rh, Ag, Cu-Cr, and Pd-Ag catalysts as part of a program to develop catalysts for lean-exhaust methanol-fueled vehicles. In general, the H/sub 2/CO oxidation behavior of the catalysts paralleled the CH/sub 3/OH oxidation behavior reported in Parts 1 and 2 of this series (Appl. Catal. 27(1986) 83; J. Catal. 103(1987) 419). Principal similarities were: high activity of Pt when there was no carbon monoxide (CO) in the feed, but strong inhibition by added CO; lower activity of Ag and Cu-Cr catalysts, but only weak inhibition due to added CO; enhanced activity of the Pd-Ag catalyst compared to Pd and Ag alone for feeds containing CO in addition to H/sub 2/CO; and, relatively poor activity of the Rh catalyst. The most unusual behavior was observed with the Pd catalyst, which showed local minima in the H/sub 2/CO conversion vs. temperature profiles. These saddles were similar to, but ...

1988-11-15

26

Burial dissolution and dolomitization relationships to moldic, stylolite and fracture porosity in the Cretaceous Sunniland Formation rudistid carbonate reservoir facies, Florida  

Energy Technology Data Exchange (ETDEWEB)

Cretaceous Sunniland Formation rudistid reservoir facies buried at 3,520 meters (92 C) between evaporite units contain marginally mature algal sapropelic carbonate source rock hydrocarbons. The closed system aids in identification of porosity redistribution related to hydrocarbon emplacement. Multiple dissolution and cementation events associated with hydrocarbon migration pulses are particularly evident along stylolites. Corrosion usually predates typically interparticle first generation saddle dolomite, and corroded saddle dolomite may be observed with two generations of optically continuous limpid overgrowths separated by a corrosive boundary. Dissolution or dedolomitization may provide a magnesium source for subsequent dolomite cements. Carbonic and organic acids are probable primary corrosive agents. Moldic, stylolite and fracture porosity, often reduced by dolomite cements, was generated. Moldic pores may develop from peloids by ...

1994-03-01

27

Simulation study of feedback systems based on a two-tap FIR filter. Under beam-beam collisions  

Energy Technology Data Exchange (ETDEWEB)

The performance of bunch-feedback systems based on two-tap FIR filters is discussed, particularly for transverse cases. Since they are the simplest type of FIR digital filters, the two-tap FIR filters should be suited to systems that require a very fast processing speed. However, in these feedback systems, a bunch must turn along a ring several times from the position-measurement to feedback kicking. Within these turns, irregular phase-jumps in the betatron motion can occur, due to several causes, such as the wake forces and beam-beam force. The discussion given in this paper is focussed on the effect of beam-beam collisions on these feedback systems. Based on linear theory and simulation studies, it has been found that these feedback systems can work with good performance, even under the influence of a strong beam-beam force. (author)

1998-04-01

28

Radiostrontium in milk and tap water  

International Nuclear Information System (INIS)

Analysis of Sr-90 in milk and tap water has been conducted in New York City since 1954. The milk sample analyzed is a monthly composite of pasteurized milk purchased daily at retail stores. The monthly Sr-90 to calcium ratios for New York City since the inception of the sampling progam in 1954 through 1981 are tabulated. Samples of New York City tap water are taken daily so that by the end of the month, approximately 100 liters have been collected. Data on Sr-90 since the inception of the program are presented. The available Cs-137 data expressed as the Cs-137 to Sr-90 ratio are given. A graphical presentation of the New York City Sr-90 data is also shown.

1982-05-01

29

Low power flux logging system for TAPS 3 and 4  

International Nuclear Information System (INIS)

This system provides data logging facility for axial profile and dynamic profile experiments during low power physics experiments. The data from Cobalt Self Powered Neutron Detectors (SPNDs) are logged via hardware consisting of PC plug-in cards and data of vanadium SPNDs are logged from the Flux Mapping System (FMS) network (multicast data). The data along with programmable details of the experiment is transferred to an Access Database. The system provides online displays and extensive reports from the Access Database as per the requirement from Reactor Physicists. This paper briefly describes the evolvement of requirements (from the experience of operation of TAPS 4 to TAPS 3), software architecture and design. (author)

2010-02-01

30

Laser-fluorescence determination of trace uranium in hot spring water, geothermal water and tap water in Xi'an Lishan region  

International Nuclear Information System (INIS)

Using the Laser-Fluorescence technique, an investigation was made, adopting the standard mix method, on trace uranium concentrations in hot spring water and geothermal water from Lishan region, and in tap water from some major cities in Shanxi province. Totally 40 samples from 27 sites were investigated. Measurement showed that the tap water contains around 10"-"6 g/L of uranium, whose concentrations in both hot spring water and geothermal water are 10"-"5 g/L. Most of samples are at normal radioactive background level, some higher contents were determined in a few samples

2002-03-01

31

Total Antioxidant Performance Is Associated with Diet and Serum Antioxidants in Participants of the Diet and Physical Activity Substudy of the Jackson Heart Study12  

UK PubMed Central (United Kingdom)

Total antioxidant performance (TAP) measures antioxidant capacities in both hydrophilic and lipophilic compartments of serum and interactions known to exist between them. Our objective was to assess...Full Text Available

2009-10-01

32

Threshold Average Precision (TAP-k): a measure of retrieval designed for bioinformatics  

UK PubMed Central (United Kingdom)

Motivation: Since database retrieval is a fundamental operation, the measurement of retrieval efficacy is critical to progress in bioinformatics. This article points out some issues with...Full Text Available

2010-07-15

33

Tendo Achillis pain: steroids and outcome.  

UK PubMed Central (United Kingdom)

A retrospective study is presented of 83 athletes with tendo Achillis pain (TAP) treated conservatively over a 12-year period from 1976 to 1988. Local steroid injections did not contribute to an earlier...Full Text Available

1992-03-01

34

Sucrose Uptake by Sugar Beet Tap Root Tissue 1  

UK PubMed Central (United Kingdom)

Sucrose uptake by discs of mature sugar beet root tissue incubated in [14C]-sucrose exhibited nonsaturating kinetics over the concentration range of 1 to 500 millimolar. Uptake was inhibited...Full Text Available

1979-11-01

35

Operant behavior of rats exposed to lead before or after weaning  

Energy Technology Data Exchange (ETDEWEB)

Rats were exposed to lead (Pb) before or after weaning. For preweaning exposures, nursing dams received 0.2% Pb acetate(1090 ppm Pb) in drinking water. Offspring treated after weaning consumed the same concentration. Tapwater served as the control fluid. Pre-post treatments were distributed among four experimental groups of 10 rats each: tap water-tap water, Pb-tap water, tap water-Pb, Pb-Pb. Operant behavior training began on Postnatal Day 58. Animals performed on a multiple reinforcement schedule of food presentation consisting of fixed-interval, fixed-ratio, and time out components.Statistical analyses of experimental sessions 4 to 11 (Postnatal Days 72 to 79) revealed that postweaning exposure significantly lengthened the median interval (interresponse time) between consecutive responses on both the interval and ratio schedules. Preweaning exposure alone tended to produce a shortening of the median ...

1982-01-01

36

Environmental levels of tritium, 2  

International Nuclear Information System (INIS)

In an attempt to obtain basic data for evaluation of exposure doses in Niigata Prefecture, the concentrations of tritium in atmospheric water, precipitation, river water, and tap water were measured. Samples of atmospheric water, river water, and tap water were collected once for 2 weeks; and precipitation collected for one week was used as sample. The concentration of atmospheric tritium depended on the concentration of tritium in moisture and the content of water in atmosphere. Tritium levels were high in May, November and March, and low in September. Regarding tritium concentrations, there was a good correlation between atmospheric water and precipitation. Tritium concentrations in both of them varied from sample to sample. The concentrations of tritium in river and tap water tended to be high during spring and low during summer and winter, although the variations were not so great as those in atmospheric water or ...

37

Development of a probabilistic timing model for the ingestion of tap water.  

Energy Technology Data Exchange (ETDEWEB)

A contamination event in a water distribution system can result in adverse health impacts to individuals consuming contaminated water from the system. Assessing impacts to such consumers requires accounting for the timing of exposures of individuals to tap-water contaminants that have time-varying concentrations. Here we present a probabilistic model for the timing of ingestion of tap water that we developed for use in the U.S. Environmental Protection Agency's Threat Ensemble Vulnerability Assessment and Sensor Placement Tool, which is designed to perform consequence assessments for contamination events in water distribution systems. We also present a statistical analysis of the timing of ingestion activity using data collected by the American Time Use Survey. The results of the analysis provide the basis for our model, which accounts for individual variability in ingestion timing and provides a series of potential ingestion times for ...

2009-01-01

39

Comparative investigation of corrosion resistance of steel reinforcement in alinite and Portland cement mortars  

Energy Technology Data Exchange (ETDEWEB)

The corrosion resistance of steel-reinforced mortar specimens made from alinite cement was investigated using ordinary Portland cement (OPC) specimens as reference. The specimens were prepared and exposed in three different environments: continuous exposure in tap water, interrupted exposure in tap water, and interrupted exposure in 3.5% NaCl solution. The steel weight loss and the half cell potential were measured vs. exposure time, up to the age of 12 months. Pore solution extraction and analysis and porosity determination were also performed. In continuous exposure in tap water, alinite cement provided adequate protection against corrosion. In interrupted exposure in tap water, a higher corrosion was observed for alinite cement compared to OPC. In the case of interrupted exposure in 3.5% NaCl solution, the simultaneous action of free chlorides and oxygen resulted in the depassivation of steel ...

1998-07-01

40

Trace metals in tap water from Tehran, Iran  

Energy Technology Data Exchange (ETDEWEB)

A total of 272 tap water samples were collected from 68 homes throughout the city of Tehran. Analysis for cadmium, zinc, lead, copper, arsenic, iron and manganese showed some accumulation of these metals in household piping overnight. However, the concentration of all metals was in the parts per billion (ug/l) range and well below international standards. Heavy metals in Tehran's drinking water therefore, do not pose a significant acute health hazard. 19 references, 2 tables.

1986-01-01

 
 
 
 
41

The protective role of ceramic filters against natural radioactivity of water  

International Nuclear Information System (INIS)

The paper presents results of measurements of the natural radioactivity of tap water where samples were taken in front of, and behind the ceramic filter commonly used in houses for the purification of tap water. Altogether, 289 samples were taken, processed and measured during 1985-1986 in Kuwait. Results reveal the fact that ceramic filters reduce substantially the natural radioactivity in water (the 'gross' alpha activity reduced by the factor 2.18 #+-# 18%; the 'gross' beta by 1.53 #+-# 1.6%. (author).

42

Spike-train bifurcation scaling in two coupled chaotic neurons  

Energy Technology Data Exchange (ETDEWEB)

We investigate the variation of the out-of-phase periodic rhythm produced by two chaotic neurons {bold (}Hindmarsh-Rose neurons [J. L. Hindmarsh and R. M. Rose, Proc. R. Soc. London B {bold 221}, 87 (1984)]{bold )} coupled by electrical and reciprocally synaptic connections. The exploration of a two-parametric bifurcation diagram, as a function of the strength of the electrical and inhibitory coupling, reveals that the periodic rhythms associated to the limit cycles bounded by saddle-node bifurcations, undergo a strong variation as a function of small changes of electrical coupling. We found that there is a scaling law for the bifurcations of the limit cycles as a function of the strength of both couplings. From the functional point of view of this mixed typed of coupling, the small variation of electrical coupling provides a high sensitivity for period regulation inside the regime of out-of-phase synchronization. {copyright} {ital 1997} {ital The American Physical ...

1997-03-01

43

From dispersion relations to spectral dimension - and back again  

CERN Document Server

The so-called spectral dimension is a scale-dependent number associated with both geometries and field theories that has recently attracted much attention, driven largely though not exclusively by investigations of causal dynamical triangulations (CDT) and Horava gravity as possible candidates for quantum gravity. We advocate the use of the spectral dimension as a probe for the kinematics of these (and other) systems in the region where spacetime curvature is small, and the manifold is flat to a good approximation. In particular, we show how to assign a spectral dimension (as a function of so-called diffusion time) to any arbitrarily specified dispersion relation. We also analyze the fundamental properties of spectral dimension using extensions of the usual Seeley-DeWitt and Feynman expansions, and by saddle point techniques. The spectral dimension turns out to be a useful, robust and powerful probe, not only of geometry, but also of kinematics.

2011-01-01

44

Excitation of global Alfven Eigenmodes by RF heating in JET  

Energy Technology Data Exchange (ETDEWEB)

The alpha-particle confinement of future D-T experiments at JET can be severely degraded by Global Alfven Eigenmodes (AE). Scenarios for the excitation of Alfven Eigenmodes in usual (e.g. D-D) plasmas are proposed, which provide a MHD diagnostic and allow the study of the transport of super-Alfvenic ions. Active studies with separate control of TAE amplitude and energetic particle destabilization, measuring the plasma response, give more information than passive studies, in particular concerning the damping mechanisms. The TAE excitation can be achieved by means of the saddle coil and the ICRH antenna. The experimental method is introduced together with a theoretical model for RF excitation. (authors). 6 refs., 3 figs.

1994-07-01

45

Estimating the erosion and deposition rates in a small watershed by the 137Cs tracing method  

International Nuclear Information System (INIS)

Understanding the erosion and deposition rates in a small watershed is important for designing soil and water conservation measures. The objective of this study is to estimate the net soil loss and gain at points with various land use types and landform positions in a small watershed in the Sichuan Hilly Basin of China by the 137Cs tracing technique. Among various land use types, the order of erosion rate was bare rock > sloping cultivated land > forest land. The paddy field and Caotu (a kind of cultivated land located at the foot of hills) were depositional areas. The erosion rate under different landform was in this order: hillside > saddle > hilltop. The footslope and the valley were depositional areas. The 137Cs technique was shown to provide an effective means of documenting the spatial distribution of soil erosion and deposition within the small watershed.

2009-02-01

46

Effects of allelochemicals produced by one population in a chemostat-like environment  

British Library Electronic Table of Contents (United Kingdom)

In this paper, we study some general models suggested to describe the effects of chemical compounds produced by an algal population on its survival in a chemostat-like environment. The conditions for its persistence and extinction are found. In particular, in the first model we make very general assumptions to represent the uptake, the regulative and the inhibiting functions, and analyze its global stability completely. In the second one we specify the first two functions and leave general the third one. Here the regulative function has different property from that in the first model, and a saddle-node bifurcation phenomenon occurs. In addition, according to the experimental data reported in DellaGreca et al. [2010. Fatty acids released by Clorella vulgaris and their role in interference w...

2011-01-01

47

Saddle field fast atom beam source: A new low pressure plasma nitriding method for a alloy Ti-6Al-4V  

Energy Technology Data Exchange (ETDEWEB)

Ti and its alloys (Ti-6Al-4V) have been used in different engineering applications due to their several outstanding properties. Nevertheless, their use in practical applications is limited in many cases due to their poor tribological property. Researches are ongoing on surface modification of Ti based materials by different plasma and ion based techniques to overcome this problem. However, the conventional plasma nitriding techniques have several problems such as formation of an arc, increased possibility of surface contamination due to a comparatively higher operating pressure, production of a very thin nitrided layer after a long processing time, etc. In this present work, the possibility of a new low-pressure plasma nitriding process using a Plasma Enhanced Chemical Vapor Deposition (PECVD) based saddle field fast atom beam source on a Ti-6Al-4V alloy sample is investigated. Plasma nitriding was carried out at 900 deg. C and at a pressure 0.1 Pa for 8 h by using ...

2006-09-25

48

Saddle field fast atom beam source: A new low pressure plasma nitriding method for a alloy Ti-6Al-4V  

International Nuclear Information System (INIS)

Ti and its alloys (Ti-6Al-4V) have been used in different engineering applications due to their several outstanding properties. Nevertheless, their use in practical applications is limited in many cases due to their poor tribological property. Researches are ongoing on surface modification of Ti based materials by different plasma and ion based techniques to overcome this problem. However, the conventional plasma nitriding techniques have several problems such as formation of an arc, increased possibility of surface contamination due to a comparatively higher operating pressure, production of a very thin nitrided layer after a long processing time, etc. In this present work, the possibility of a new low-pressure plasma nitriding process using a Plasma Enhanced Chemical Vapor Deposition (PECVD) based saddle field fast atom beam source on a Ti-6Al-4V alloy sample is investigated. Plasma nitriding was carried out at 900 deg. C and at a pressure 0.1 Pa for 8 h by using ...

2006-09-25

49

Tritium in surface waters, tap water and in precipitation in Poland during the 1994-1999 period  

International Nuclear Information System (INIS)

Concentrations of tritium in environmental waters (precipitation, rivers, lakes, tap water) have been determined using electrolytic enrichment and liquid scintillation counting. In waters of big rivers (the Vistula and the Odra rivers), lakes and tap water the annual average concentrations were similar to each other being from 1.4 to 1.9 Bq x dm"-"3. These concentrations were similar to those in the precipitation in which they ranged from 1.7 to 2.2 Bq x dm"-"3. The lowest tritium concentrations were found in waters of the Seashore Region rivers (average for 1994-1999 was 1.1 Bq x dm"-"3). The tritium concentrations in surface waters and in precipitation are still higher than that of natural level. The data obtained show that tritium concentration in the water of rivers might depend on the size of drainage area. The observed seasonal variations of tritium concentration in the precipitation collected in Warsaw and at the Mount Sniezka indicate ...

2001-01-01

50

The transfer of trichloroethylene (TCE) from a shower to indoor air: Experimental measurements and their implications  

Energy Technology Data Exchange (ETDEWEB)

Experiments were performed to measure the transfer of trichloroethylene (TCE), a volatile organic compound (VOC), from tap water in showers to indoor air. In these experiments, the loss of TCE from tap water in the shower is based on the difference between influent and effluent concentrations.We have developed and previously published a three-compartment model, which we use to simulate the 24-h concentration history of VOCs in the shower, bathroom, and remaining household volumes resulting from the use of contaminated tap water. An important input to this model is the transfer efficiency of the VOC from water to air. The experiments reveal that the transfer efficiency of TCE from shower water to air has an arithmetic mean value of 51 percent and an arithmetic standard deviation of 9 percent. Analysis of the results shows that there is no statistically significant difference between the transfer efficiency measured with hot ...

1991-08-01

51

Human exposure to volatile organic compounds in household tap water: the indoor inhalation pathway  

International Nuclear Information System (INIS)

This paper addresses the quantification of human exposure to volatile organic compounds (VOC's) as a result of mass transfer from tap water to indoor air. A three-compartment model is developed and used to simulate the 24-h concentration profile within the shower, bathroom, and remaining household volumes of a dwelling. Mass transfers from water to air are derived from measured data for radon and adjusted to account for the difference in mass-transfer properties for VOC's. A preliminary data base for household parameters is used to calculate a range of concentrations and human exposures in U.S. dwellings. The model is used to estimate exposure factors for seven compounds-chloroform, ethylene dibromide, dibromo-chloropropane, methylchloroform, perchloroethylene, trichloroethylene, and carbon tetrachloride. The calculated ratio of indoor-air exposure to tap water concentration is compared to measured values for one of the compounds, chloroform. A ...

52

Growth and reproduction of nematodes isolated from tap water; Suidosui kara bunrisareta senchurui no zoshoku tokusei  

Energy Technology Data Exchange (ETDEWEB)

This paper elucidates morphological characteristics, reproduction forms and ecological characteristics of Plectus sp. and Rhabditis sp. which are most frequently detected nematodes separated from tap water. The paper also discussed experimentally establishment of cultivating conditions for these nematodes, and behavior and reproduction characteristics of nematodes under widely ranging conditions of temperatures, bacteria concentrations and pH. Plectus sp. grows in hermaphroditic individuals, while Rhabditis sp. grows only in female. An LE culture medium can cultivate nematodes that appear in tap water, and is suitable for subculture of nematodes. Conditions of temperatures from 20{degree}C to 25{degree}C, pH and inoculated concentration of bacteria at 10{sup 8} cell {center_dot} ml{sup -1} are suitable for reproduction of Plectus sp. and Rhabditis sp. Plectus sp. and Rhabditis sp. prefer mild temperatures for reproduction, cannot reproduce ...

1996-08-10

53

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

54

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal the error involved. The calibration facility and calibration techniques established at ...

2008-11-19

55

Design modifications in radiation monitoring system at Tarapur Atomic Power Station 3 and 4  

International Nuclear Information System (INIS)

Inputs on radiological conditions forms the basis of implementation of effective exposure control to plant personnel in nuclear power station. Radiation monitoring system provides this input to the plant operator as well as to health physics group. Several design modifications have been incorporated in the Radiation Monitoring System at Tarapur Atomic Power Station (TAPS 3 and 4) over the similar systems at Kakrapar Atomic Power Station (KAPS) and Kaiga Generating Station (KGS). The radiological monitoring systems installed at TAPS unit 3 and 4 includes on line Radiation Data Acquisition System (RADAS), Emergency sampling system, effluent monitoring system and environmental monitoring system. The design changes and the versatile use of these systems are presented in this paper. (author)

2006-11-13

56

Thermogalvanic effects on the pitting corrosion of water-cooled heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heat exchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.

1995-05-01

57

Tap cogen-plant steam for process, NO[sub x] control  

Energy Technology Data Exchange (ETDEWEB)

This article describes the Monsanto's Indian Orchard plant gas-fired, combined-cycle cogeneration facility in Springfield, Massachusetts. The topics of the article include project configuration, the thermodynamic cycle, fuel selection, electrical distribution system, plant control, and air pollution control of NO[sub X], SO[sub 2], CO, particulates, non-methane hydrocarbons, opacity and ammonia.

1993-04-01

58

Spectrophotometric determination of aluminium ion in drinking water by flow infection analysis  

International Nuclear Information System (INIS)

Optimum analytical conditions of the aluminium ion were established by flow injection analysis. Eriochrome Cyanine R(ECR) dye reacts with the aluminium ion at pH 6.0 form a complex that exhibits maximum absorption at 535 nm. Reaction condition including the mixing and the reaction coil length, the concentration and the pH of the buffer solution, temperature, and injection loop volume were optimized to introduce this reaction into flow injection analysis. The results were as follows. A mixing coil length of 0.5 m and a reaction coil length of 4.0 m, the pH 6.0 and 1M of acetate buffer solution, the ECR concentration of 0.56 mM, the reaction temperature of 40 .deg. C, the injection loop volume of 300 #mu#L were chosen as optimum conditions. Under these conditions the detection limit of the aluminium ion was less than 0.05 mg/L and the repeatability was better than 1%. A sampling frequency of 24 times for an hour was achieved. Interfering ions such as F"-, HPO_4"2"-, Fe"2"+, Fe"3"+, ...

2000-10-01

59

Smart Takes - Archive: April 2011 | SmartPlanet  

Wastenet

... April 29, 2011, 8:25 AM PDT | By Andrew Nusca Ottawa taps Itron for 210,000 smart water meters The City of Ottawa has chosen smart grid firm Itron ...to deploy smart water meters and related infrastructure in town. April 29, 2011, 7:18 AM PDT | By Andrew ...

60

Lead exposure via drinking water - unnecessary and avoidable  

International Nuclear Information System (INIS)

Despite successful reduction of the general lead exposure, this heavy metal is still a matter of public concern due to the fact that associations with intellectual impairment or delayed puberty are found to correlate with very low lead blood concentrations. Lead in tap water is still an important contribution to lead exposure which may cause health risk for infants. Therefore, lead pipes should be completely sanitated by exchange against pipes made from more healthy materials. (orig.)

 
 
 
 
61

Flux mapping system for TAPS 3 and 4: software perspective  

International Nuclear Information System (INIS)

The Flux Mapping System (FMS) of 540 MWe PHWR is a system, which is first of its kind used in Indian PHWRs. It is used to compute a detailed flux/power distribution of the reactor core using modal synthesis method .The paper brings out the high availability features of FMS and the software design philosophy. The paper emphasizes on framework based reusable architectural design, which simplifies and speeds up the development of data acquisition systems. (author)

2010-02-01

62

Activities and activity ratios of U and Ra radioisotopes in drinking wells, springs and tap water samples in Morocco  

International Nuclear Information System (INIS)

Radiochemical results ("2"3"4U, "2"3"8U, "2"2"6Ra and "2"2"8Ra activities; "2"3"4U/"2"3"8U, "2"2"8Ra/"2"2"6Ra and "2"2"6Ra/"2"3"8U activity ratios) are reported for 31 drinking water samples collected from 8 wells, 12 hot mineral springs, 5 cold springs, and 6 tap water samples. Activities of the Ra isotopes were measured by gamma spectrometry using a low background and high efficiency well type germanium detector. The U isotopes were counted in an alpha spectrometer. The results show that "2"3"8U activity varies between 4.46 and about 308 mBq l"-"1 in wells, 0.59 and 17.88 mBq l"-"1 in hot springs, 2.19 and 3.21 mBq l"-"1 in cold springs, and between 2.5 and 15.70 mBq l"-"1 in tap water samples. "2"3"4U/"2"3"8U activity ratio is generally higher than 1 which is the equilibrium activity ratio value in closed systems. It varies in the ranges 0.79-2.11 in wells, 0.97-7.39 in hot springs, 2.53-8.30 in cold springs, and 1.14-3.35 in ...

63

Neural net formulations for organically modified, hydrophobic silica aerogel  

Energy Technology Data Exchange (ETDEWEB)

Organic modification of aerogel chemical formulations is known to transfer desirable hydrophobicity to lightweight solids. However, the effects of chemical modification on other material constants such as elasticity, compliance, and sound dampening present a difficult optimization problem. Here a statistical treatment of a 9-variable optimization is accomplished with multiple regression and an artificial neural network (ANN). The ANN shows 95 percent prediction success for the entire data set of elasticity, compared to a multidimensional linear regression which shows a maximum correlation coefficient, R=0.782. In this case, using the Number of Categories Criterion for the standard multiple regression, traditional statistical methods can distinguish fewer than 1.83 categories (high and low elasticity) and cannot group or cluster the data to give more refined partitions. A non-linear surface requires at least 3 categories (high, low, and medium elasticities) to define its curvature. To ...

1997-07-01

64

Fragment angular momenta in low and medium energy fission of /sup 242/Pu  

Energy Technology Data Exchange (ETDEWEB)

Independent isomeric yield ratios of /sup 128/Sb were determined radiochemically in the thermal neutron induced fission of /sup 241/Pu and 34 MeV alpha particle induced fission of /sup 238/U, both involving the same compound nucleus (/sup 242/Pu). Fragment angular momenta estimated from the measured isomer ratios using the statistical model analysis showed significantly larger fragment angular momenta in the medium energy fissioning system compared to the low energy fissioning system. This has been attributed to the effect of higher excitation energy and angular momentum in the entrance channel leading to increased fragment temperature, moments of inertia and angular velocity. An attempt was made to calculate the fragment angular momentum in the medium energy fission using the Fermi gas model for the fissioning nucleus, taking into account the multichance fission, saddle shapes of the fissioning nuclei and the angular velocity components of the fissioning nuclei ...

1987-06-01

65

Electrical human-power transmission. The bicycle technology of the 21st century; Elektrische Muskelkrafttransmission. Fahrradtechnologie des 21. Jahrhunderts. Schlussbericht  

Energy Technology Data Exchange (ETDEWEB)

Since 1994-95 the University of Applied Sciences Berne is working on weather-proof electric bicycles. The main drawbacks of bicycles, no weather-protection, little comfort of the saddle, the difficulty of climbing hills, are to be eliminated. The electro-mechanical drive-train of 'Ultraleichtmobil ULM BE 2000', developed in 1995-96, was mechanically complicated. This resulted in reduced energy-efficiency and intense maintenance. Too, the drive-train was expensive in production. A fully electrical human-power transmission seemed to be the solution to the problems mentioned above. It is appealing not only to the user of the vehicle, but also to the producer and to the persons doing the maintenance. Following an internal study showing the technical feasibility of such an electrical transmission, a controllable DC/DC-converter which allows to operate a pedal-driven generator at maximum efficiency has been developed. The electrical transmission is the ...

1999-12-01

66

Tritium analysis in environmental samples around Nuclear Power Plants and nationwide surveillance of radionuclides in some environmental samples(meat and drinking water)  

Energy Technology Data Exchange (ETDEWEB)

12 kind of environmental samples such as soil, underground water, seawater, etc. around the Nuclear Power Plants(NPP) and surface seawater around the Korea peninsula were sampled, For the samples of rain, pine-needle, air, seawater, underground water, chinese cabbage, grain of rice and milk sampled around NPP, and surface seawater and rain sampled all around country, tritium concentration was measured, The tritium concentration in the tap water and the gamma activity in the domestic and imported beef that were sampled at ward in the large city in Korea(Seoul, Pusan, Taegu, Taejun, Inchun, Kwangju) were analyzed for the meat and drinking waters. As the results of analyzing, tritium concentration in rain and tap water were very low all around country, but a little higher around the NPP than general surrounding. At the Wolsung NPP, tritium concentration was descend according to distance from the stack. Tritium activity of surface seawater around ...

2001-12-15

67

Study of dose rates and radionuclides contributing to dose rates in India's 540 MWe pressurised heavy water reactors  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, Moderator systems, cover gas system and other auxiliary system for ...

2006-11-13

68

Strontium-90 and cesium-137 in service water from June to December, 1981  

International Nuclear Information System (INIS)

Service water, 100 l each, was collected at an intake of a water treatment plant and at a tap after water was left running for five minutes. The carriers of strontium and cesium were added to water immediately after sampling, and the sample was vigorously stirred and filtered. Then it was passed through a cation exchange column at a rate of 80 ml/min. Strontium and cesium were eluted with hydrochloric acid from the cation exchange column, and separated. After the radiochemical separation, the mounted precipitates were counted for activity using low background beta counters normally for 60 min. Net sample counting rates were corrected for counter efficiency, recovery, self absorption and decay to obtain the content of strontium-90 and cesium-137 radioactivity per sample aliquot. From the results, concentrations of these nuclides in the original sample were calculated. The maximum values obtained were 0.29 pCi/l of Sr-90 in Kyoto in August, 1981, and 0.02 pCi/l of ...

1981-12-01

69

Radiolysis and photolysis of crystalline 2,4,6-triazido-3,5-dichloropyridine: generation of quintet dinitrenes  

International Nuclear Information System (INIS)

Low-temperature #gamma# radiolysis and photolysis of crystalline 2,4,6-triazido-3,5-dichloropyridine (TAP) were studied by means of the ESR technique. It was found that the long-term irradiation of TAP at 77 K leads to the appearance of characteristic signals of quintet 2,6-dinitreno-4-azido-3,5-dichloropyridine and 2,4-dinitreno-6-azido-3,5-dichloropyridine; the radiation-chemical yield was 0.035 and 0.012 molecule/100 eV, respectively. The photolysis of crystalline 2,4,6-triazido-3,5-dichloropyridine proceeded less effectively, producing only quintet 2,6 dinitrene with a quantum yield of #approx#4.5 x 10"-"4. The study showed that the generation of high-spin nitrenes via radiolysis of crystalline azides is much superior to the photochemical technique in efficiency and may be of practical importance for the preparation of magnetically active organic materials

70

Natural radionuclides in drinking water in Argentina  

International Nuclear Information System (INIS)

As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age distribution and the measured concentrations, an annual collective effective dose of 1.9 man Sv and an ...

2000-05-01

71

Determining the locations of faults in distribution systems  

Energy Technology Data Exchange (ETDEWEB)

Location of transmission line faults are traditionally estimated by measuring the apparent impedance from a line terminal to the fault and converting the reactive component of the impedance to line length. None of the methods proposed to date address adequately the problems of fault location on distribution systems that have single or multiphase laterals and/or tapped loads. The research for this dissertation resulted in the development of a technique that estimates the location of a shunt fault on a radial distribution system that has several single and/or multiphase laterals. The technique takes into account load taps and non-homogeneity of the system, and has been tested for its ability to handle single-phase-to-ground, two-phase-to-ground, phase-to-phase and balanced three-phase faults. Computer simulations indicate that the technique is more accurate than the reactive component method. Results from a prototype of the technique was tested ...

1998-12-01

72

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % full power, through ...

2005-11-23

73

Uptake of iodine-131 in gaseous state on Ag-impregnated amberlite IR-120 resin and its comparison with activated charcoal. [dry and wet conditions  

Energy Technology Data Exchange (ETDEWEB)

The paper describes uptake of gaseous lodine-131 on silver impregnated organic resin, Amberlite IR-120, available at the Secondary Steam Generator (S.S.G.) Opening at T.A.P.S. in comparison with activated charcoal. The experiments are conducted in dry and wet conditions by soaking the impregnated resin and activated charcoal in distilled water for wet condition. The paper also describes the iodine sampler specially designed and fabricated for these experiments.

1982-01-01

74

The use of the isotope "3"2P in the study of some ecological aspects of a laboratory stream ecosystem  

International Nuclear Information System (INIS)

A laboratory stream consisting of two stream sections interrupted by two pools was filled with a mixture of tap water and organically enriched water from rivers nearby. Bottom sediment material, Potamogeton pectinatus, macro-invertebrate organisms, as well as the mosquito fish, Aplocheilichthys johnstonii were collected from rivers around Johannesburg and introduced into the laboratory stream. After initial acclimatization, the distribution of the isotope "3"2P through this laboratory stream was followed. Absorption of this isotope by benthic algae, Potamogeton pectinatus, several macro-invertebrate organisms as well as Aplocheilichthys johnstonii was recorded.

75

LET-dependence of the trapping parameters in TLD-100 determined with a computerised curve fitting method  

International Nuclear Information System (INIS)

With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).

1985-10-22

76

Excessive copper concentrations in the tap water of households with copper pipes and an assessment of possible health hazards for infants. First results of a study; Gesundheitliche Gefaehrdung ungestillter Saeuglinge durch Kupfer in Haushalten mit kupfernen Trinkwasserleitungen. Erste Ergebnisse einer prospektiven Studie  

Energy Technology Data Exchange (ETDEWEB)

To determined precisely a possible connection between the amount of copper in tap-water and the risk of early childhood liver disease, it was attempted through an epidemiological survey, to determine the extent of excessive concentrations of copper in the tap-water of households with copper pipes. Water samples from 956 households were tested for copper, and the state of health of the infants in these households was documented. Infants who had been fed using water with a copper concentration of 0.8 mg/l or more received a paediatric examination with a blood serum analysis to rule out any liver damage. A copper level greater than 0.8 mg/l was found in only 2% of the households examined. Eight infants were examined by a paediatrician and their serum was analysed. These infants had either been breast-fed to the 12th week or had received more than 200 ml of tap water per day during first 12 months. None of the infants examined ...

2000-04-01

77

Assessing NDVI Spatial Pattern as Related to Irrigation and Soil Salinity Management in Al-Hassa Oasis, Saudi Arabia  

British Library Electronic Table of Contents (United Kingdom)

Sustainability of irrigated agriculture in arid and semi arid lands depends, mainly on the level of soil salinity and the quality of irrigation water. Remotely sensed data can provide information about the extent of vegetated irrigated areas. Al-Hassa oasis, Saudi Arabia is probably the largest oasis in the world depends mostly on tapped ground water to irrigate mainly date palm groves for its economic survival. This study tried to investigate the extent of soil salinity and the quality of irrigation water and the relationship with vegetation growth, employing NDVI derived from Landsat satellite imagery.

2011-01-01

78

An investigation of the retention of some radioelements on natural fibers  

International Nuclear Information System (INIS)

The retention of radio-Eu, Go, Cs and Sr, at the tracer level, on raw fibers produced from hemp, linen and Jute plants was investigated. The study was conducted from different media including: sea and tap waters, sodium chloride and nitric acid solutions of different Ph. The percentage retention and elution, on prolonged contact, varied from one element to another depending on conditions. Extraction chromatography columns, using these fibers as supporting material were also experimented. Results were discussed together with possible applications. 7 tabs.

79

AFS Cupola Model Verification--Initial Investigations  

Science.gov (United States)

The cupola furnace is used to melt scrap steel, pig iron, foundry returns, and alloying additives to a prescribed tapping chemistry and temperature for iron casting applications. The melting process within the cupola is highly complex and not well quantified. The American Foundrymen's Society is developing a mathematical model to aid in the understanding of these processes. This model is reaching maturity, and has been successful in estimating a number of melting parameters. This paper details the results of efforts to verify the model in a controlled system, equipped wit the appropriate sensors, for model verification. The work was performed on a research-scale cupola furnace located at the Department of Energy's Albany Research Center.

1998-01-01

80

A new reconfiguration scheme for voltage stability enhancement of radial distribution systems  

International Nuclear Information System (INIS)

Network reconfiguration is an operation problem, which entails altering the topological structure of the distribution feeders by rearranging the status of switches in order to obtain an optimal configuration in order to minimise the system losses. This paper presents a new reconfiguration algorithm that enhances voltage stability and improves the voltage profile besides minimising losses without incurring any additional cost for installation of capacitors, tap changing transformers and related switching equipment in the distribution system. Test results on a 69 node distribution system reveal the superiority of this algorithm.

2009-09-01

 
 
 
 
81

Effect of wet-dry cycling on swelling and hydraulic conductivity of GCLs  

Energy Technology Data Exchange (ETDEWEB)

Atterberg limits, free swell, and hydraulic conductivity tests were conducted to assess how wet-dry cycling affects the plasticity and swell of bentonite, and the hydraulic conductivity of geosynthetic clay liners (GCLs) hydrated with deionized (DI) water (pH 6.5), tap water (pH 6.8), and 0.0125-M CaCl{sub 2} solution (pH 6.2). The plasticity of bentonite hydrated with DI water increased during each wetting cycle, whereas the plasticity of bentonite hydrated with tap water and CaCl{sub 2} decreased during each wetting cycle. Wet-dry cycling in DI water and tap water had little effect on swelling of the bentonite, even after seven wet-dry cycles. However, swelling decreased dramatically after two wetting cycles with CaCl{sub 2} solution. Hydraulic conductivity of GCL specimens remained low during the first four wetting cycles ({approximately}1 x 10{sup {minus}9} cm/s). However, within five to eight cycles, the hydraulic ...

2000-01-01

82

Corrosion of aluminum and copper thin films under simulated atmospheric conditions in laboratory tests  

Energy Technology Data Exchange (ETDEWEB)

Corrosion characteristics of Al and Cu thin films have been studied in cyclic fog tests using tap water fog and fog created with 0.1% NaCl solution in tap water. Likewise, their corrosion features have been analyzed in continuous immersion testing in the laboratory in distilled water, tap water, in 0.1% NaCl and 3.5% NaCl solutions in distilled water. The corrosion potentials and the corrosion currents of these thin films change and reach steady state values after some time. However, steady state is not realized in 3.5% NaCl solutions. The corrosion current density data have been used to calculate lifetime of 1 {mu}m thick thin films of Al and Cu in the various tests, and assuming that the fog test data would hold under normal exposure conditions, life spans for these thin film sensor elements in actual exterior exposure have also been calculated. According to estimates, an Al-TF of about 1 {mu}m would last about 9 months ...

1998-12-31

83

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low ...

2000-09-01

84

Experimental studies of selective acid gas removal: Absorption of hydrogen sulfide and carbon dioxide into aqueous methyldiethanolamine using packed columns  

Energy Technology Data Exchange (ETDEWEB)

The use of aqueous methyldiethanolamine (MDEA) for selective removal of hydrogen sulfide from acid gas streams has been studied in a 2 inch column packed with 1/4 inch ceramic Intalox saddles. The column was operated in a counter-current, steady state fashion. The feed gas composition varied between 1 and 5 mole % hydrogen sulfide and between 0 and 50 mole % carbon dioxide. In order to assist the development of packed column absorption models, the rate at which pure carbon dioxide absorbs into 2 M MDEA was measured as a function of pressure, liquid flow rate and packed bed length. The importance of end effects was carefully evaluated. In addition, draining and tracer methods were used to estimate the amount of static holdup present in the column. Using classical draining methods, as much as 50 % of the total holdup was found to be static. However, according to the step decrease in tracer method, less than 5 % of the total holdup was static. Since the step decrease ...

1988-01-01

85

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated each wire into its own plane. At various ...

2006-03-01

86

Supply chain networks and service-dominant logic: suggestions for future research  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The service-dominant (S-D) logic views supply chains as value co-creation networks. These networks promote knowledge growth amongst network members via resource deployment and coordination. The exchange of knowledge and utilization of operant resources among the network members leads to co-created service offerings and value proposals for the end-users, with the ultimate goal of transforming end-user experiences to perceptions of superior value-in-use. The purpose of this paper is to develop an illustration of the value co-creation concept and use this illustration as guide to examine the research gaps that are yet to be tapped in the area where supply chain networks and S-D logic intersects. Design/methodology/approach - The literature on S-D logic is reviewed and research gaps ...

2011-01-01

87

Study on tritium activity build-up in moderator and primary heat transport systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2006-11-13

88

Study on tritium activity build-up in moderator and primary heat transport (PHT) systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2005-11-23

89

Study of seasonwise variations in the environmental gamma dose rates in Tarapur emergency planning zone (EPZ)  

International Nuclear Information System (INIS)

During the normal operation of a Nuclear Power Plant (NPP), radioactive releases into the atmosphere will be in small quantities. During major accidental situations, though the probability is extremely small, there may be significant release of radioactivity to the environment through the stack or at ground level. To study the external radiation exposure, if any, to the members of public due to releases during the normal operation of a nuclear power plant (NPP) and also to meet the requirement of emergency preparedness for the NPP site, continuous recording and analysis of environmental dose rate data is essential. This paper presents analysis of the gamma dose rates recorded by the Environmental Dose Logging Systems (EDLS) installed around the site during the last six years in the Emergency Planning Zone (EPZ) of Tarapur Atomic Power Station (TAPS). (author)

2005-11-23

90

Sorbent materials for fusion reactor tritium processing  

Energy Technology Data Exchange (ETDEWEB)

A fusion reactor (such as NET/ITER) which breeds its own tritium fuel requires tritium recovery, purification and separation from the other isotopes. Cyclic adsorption processes are strong candidates for several of the processes involved: amongst other advantages, they promise a low tritium inventory. A good adsorbent for such processes must have high adsorption capacity, high selectivity and very low tritium retention after each cycle. Pure zeolite powder is shown to have an excellent combination of these three properties. However, in practice problems can arise from tritium which is not removed by reactivation. In this paper we show that tritium retention in zeolites can be caused either by water retained in the zeolite structure, which can be removed by ore rigorous activation, or by water tapped on binders in commercial pellets. (orig.).

1995-03-01

91

Shielding augmentation for HFU penetration in calandria vault of 540 MWe PHWR  

International Nuclear Information System (INIS)

This paper consists the radiation streaming analysis of Horizontal Flux Unit (HFU) penetrations in Calandria Vault of 540 MWe PHWR. There are total 7 HFU penetrations on west wall of calandria vault. As these penetrations are in accessible area, a detailed analysis has been carried out to find the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out Using the computer code MCNP and DOT-III. Based on the predictions at HFU penetrations, shielding arrangement was recommended. Neutron and gamma dose rate higher than estimated were observed at TAPS-4. This was because of installed shield not being similar to recommended one due to site conditions. Subsequently semi-empirical calculations using measured data were carried out by MCNP to further augment the existing shield taking into consideration the space limitations at site. (author)

2006-11-13

92

Seasonal and clonal variations in technological and thermal properties of raw Hevea natural rubber  

British Library Electronic Table of Contents (United Kingdom)

Abstract This study was undertaken over a 10-month period under environmental conditions within the state of Mato Grosso, Brazil, to evaluate the causes of variation in the technological and thermal properties of raw natural rubber (NR) from different clones of Hevea brasiliensis (GT 1, PR 255, FX 3864, and RRIM 600). These clones were chosen to represent good clones available in Brazil. The technological properties of raw NR were evaluated in terms of their dry rubber content (DRC), Wallace plasticity, plasticity retention index (PRI), and Mooney viscosity. The thermal performance was evaluated with the thermogravimetry (TG)/differential thermogravimetry (DTG) technique. There were significant variations (p < 0.01 and p < 0.05) between clones and tappings for all technological properties,...

2011-01-01

93

Psychological test performance in foundry workers exposed to low levels of manganese  

Energy Technology Data Exchange (ETDEWEB)

A sample of 30 manganese-exposed foundry workers from two Swedish plants were examined with a partly computerized psychological test battery, comprised of 10 performance tests. Performance of the manganese-exposed workers was compared to that of a matched control group of 60 workers. Matching criteria were age, geographical area, type of work, and the results on a test of verbal comprehension. Performance of the exposed workers was inferior to that of the control group on tests of simple reaction time, digit span, and finger tapping. No correlations were found between performance and the present manganese exposure levels or the number of years employed in manganese work. The results seem to indicate that the present exposure standards for manganese, in Sweden 2.5 mg/m3 and in most other countries 5 mg/m3, are not sufficient to protect workers from negative effects on performance capacity.

1990-11-01

94

Pre-test report on international round robin analysis of BARC containment (BARCOM) test model  

International Nuclear Information System (INIS)

BARC has organized an international round robin analysis program to carry out the ultimate load capacity assessment of BARC containment (BARCOM) test model. The test model located in BARC facilities Tarapur, is a 1:4 scale representation of 540 MWe pressurized heavy water reactor (PHWR) pre-stressed concrete inner containment structure of Tarapur Atomic Power Station (TAPS) unit 3 and 4. The features of the BARCOM test model and the constitutive data for the pre-test analysis along with the comparison of the results submitted by various participants are described in this pre-test report of the round robin analysis of BARCOM test model

2009-01-01

95

Numerical simulation of slagging films in the Aachen pressurized coal combustion facility  

Energy Technology Data Exchange (ETDEWEB)

Combined gas and steam turbine processes based on direct coal firing show a high thermal efficiency. At RWTH Aachen, University of Technology, an experimental test furnace has been built to investigate the pressurized pulverized coal combustion (PPCC). The PPCC-facility has been constructed as a slag tap furnace. Particles hitting the walls at temperatures above the melting point cause slagging depositions and create a film flowing down the reactor walls. As a part of the PPCC-program different mathematical models have been developed and implemented into the CFD-code FLUENT to predict the behavior of slag films at the furnace walls. Numerical strategies and the mathematical models used are described in detail. 12 refs., 9 figs.

2001-07-01

96

Methanol production FPSO plant concept using multiple microchannel unit operations  

British Library Electronic Table of Contents (United Kingdom)

Remote, offshore gas reserves have long been a challenging deepwater petroleum resource to tap. Natural gas in many offshore regions is plentiful, but lacks access to the market because of the logistical challenges and costs. Most large offshore gas discoveries are capped, and gas associated with oil production is re-injected into the reservoir or is flared. A more attractive option is to convert the gas into a liquid product on a floating production, storage, and offloading (FPSO) vessel. However, some conventional process technologies are not well suited for operation on floating vessels that are highly space and weight constrained and may challenge vessel stability during inclement weather. Microchannel process technology units under development offer intensified processes that are suit...

2008-01-01

97

Measuring perceptual centers using the phase correction response  

British Library Electronic Table of Contents (United Kingdom)

The perceptual center (P-center) is fundamental to the timing of heterogeneous event sequences, including music and speech. Unfortunately, there is currently no comprehensive and reliable model of P-centers in acoustic events, so P-centers must instead be measured empirically. This study reviews existing measurement methods and evaluates two methods in detail?the rhythm adjustment method and a new method based on the phase correction response (PCR) in a synchronous tapping task. The two methods yielded consistent P-center estimates and showed no evidence of P-center context dependence. The PCR method appears promising because it is accurate and efficient and does not require explicit perceptual judgments. As a secondary result, the magnitude of the PCR is shown to vary systematically with ...

2011-01-01

98

Managing a large outbreak of cryptosporidiosis: how to investigate and when to decide to lift a 'boil water' notice.  

Science.gov (United States)

The largest outbreak of cryptosporidiosis reported in the United Kingdom, involving 575 confirmed cases (of which 474 met an agreed case definition), occurred in the county of Devon during August and September of 1995. The descriptive epidemiology supports the hypothesis that the outbreak was associated with the consumption of cold tap water in the area served by a particular water treatment works. Cryptosporidium oocysts were detected in treated water samples at the time of the outbreak. Although the epidemiological analysis provided strong circumstantial evidence of a waterborne outbreak, the data were not recorded in a manner that made them admissible in criminal proceedings taken by the Drinking Water Inspectorate against the water company involved. The need to carry out an analytical study in conjunction with the identification and characterisation of the pathogen in the drinking water and the practicalities of agreeing criteria for lifting a 'boil water' ...

2002-09-01

99

Geothermal resources of the Green River Basin, Wyoming, including thermal data for the Wyoming portion of the Thrust Belt  

Energy Technology Data Exchange (ETDEWEB)

The geothermal resources of the Green River basin were investigated. Oil-well bottom-hole temperatures, thermal logs of wells, and heat flow data have been interpreted within a framework of geologic and hydrologic constraints. Basic thermal data, which includes the background thermal gradient and the highest recorded temperature and corresponding depth is tabulated. It was concluded that large areas are underlain by water at temperatures greater than 120/sup 0/F. Although much of this water is too deep to be economically tapped solely for geothermal use, oil and gas wells presently provide access to this significant geothermal resource. Isolated areas with high temperature gradients exist. These areas - many revealed by hot springs - represent geothermal systems which might presently be developed economically. 34 refs., 11 figs., 8 tabs. (ACR)

1985-01-01

100

Direct injection of natural gas in blast furnaces at high rates: Preliminary statistical analysis of blast furnace carbon balance at Armco-Middletown. Topical report, January 1990-September 1992  

Science.gov (United States)

The economic benefits of supplemental fuel injections depend, in part, on the coke replacement ratio. An assessment of the accuracy with which blast furnace coke rate may be measured and a determination of the key drivers of coke rate uncertainty are offered, to provide guidance for experiments in high-rate gas injection. Using statistical analysis tools, an expression for the measurement error associated with the various terms of blast furnace carbon balance is developed. Coke rate calculations based on the material balance are most sensitive to coke carbon content and to proper tracking of hot metal tapping schedule.

1992-09-01

 
 
 
 
101

Development of barcode system for internal dose monitoring  

International Nuclear Information System (INIS)

In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose monitoring. This paper discusses about the use of barcode system in the internal dose monitoring at TAPS 3 and 4. (author)

2008-11-19

102

Crop diversification and trade liberalization: Linking global trade and local management through a regional case study  

British Library Electronic Table of Contents (United Kingdom)

Some models anticipate that liberalized agricultural trade will lead to increased crop diversity, while other models make the opposite claim. These positions were explored in southwestern British Columbia, Canada where, between 1992 and 1998, government subsidies and other measures designed to protect horticultural farmers were lifted, exposing these farmers to foreign competition. Public hearings on the future of agriculture provided an opportunity to tap the knowledge and experience of people affected by this transition. Analysis of transcripts from these hearings, which was confirmed by industry data, shows that trade liberalization has led to the loss of the local fruit and vegetable processing industry. Stakeholders saw the loss as a major factor affecting the choice of crops grown lo...

2006-01-01

103

Characterization of polymer solar cells by TOF-SIMS depth profiling  

Energy Technology Data Exchange (ETDEWEB)

Solar cells consisting of polymer layers sandwiched between a transparent electrode on glass and a metal top electrode are studied using dynamic time-of-flight secondary ion mass spectrometry (TOF-SIMS) in dual-beam mode. Because depth profiling of polymers and polymer-metal stacks is a relatively new field the craters were thoroughly investigated by environmental SEM (ESEM), interferometry, surface profilometry and tapping mode AFM. A huge increase in crater bottom roughness was observed when starting from the aluminum top layer going in depth, resulting in a loss of depth resolution. It is shown that layer-to-layer diffusion and contaminants at buried interfaces can be extracted from the depth profiles when taking into account the loss of depth resolution.

2003-01-15

104

Canadian R&D on oil-fired combustion systems  

Energy Technology Data Exchange (ETDEWEB)

This paper describes research and development presently being conducted on oil-fired space and tap water heating systems by the Advanced Combustion Technology Group, CCRL/ERL/CANMET, in Ottawa, Canada. The presentation will focus on R&D activities at CCRL in support of the Canadian Oil Heat Association (COHA) and of the energy policy initiatives of Natural Resources Canada. Progress will be reported on activities to develop suitable oil-fired integrated systems to satisfy the low energy demands of new homes. The utilization of fuzzy logic-based control heating systems including fan coils for a complete range of old and new North American housing will be discussed. Additional activities to be discussed in the presentation will relate to the development of appropriate seasonal efficiency standards for complex integrated space/water heating systems, as well as an evaluation of alternative sidewall venting technologies and their implications for seasonal energy ...

1996-07-01

105

Application of nuclear energy for power generation at TAPS 3 and 4  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station, Unit 3 and 4 is located on the West Coast of the Arabian Sea near the existing Tarapur Atomic Power Station Unit 1 and 2. The nearest railway station is Boisar at a distance of 12 km from the site, which is on the main Western Railway Mumbai-Delhi route. The site is well connected by road and is about 30 Km from Mumbai-Ahmedabad National Highway-NH-8. The paper describes the land acquisition and rehabilitisation of the affected families, importance of project in the western grid, how it works, working principles of PHWR, principle of operation, major components/equipment, important systems, safety features, and waste management

2010-10-01

106

Active catalytic sites in the ammoxidation of propane and propene over V-Sb-O catalysts  

Energy Technology Data Exchange (ETDEWEB)

The ammoxidation of propane over VSb{sub y}O{sub x} catalysts (y=1, 2, 5) was investigated with respect to the role of different oxygen species in the selective and non selective reaction steps using transient experiments in the Temporal Analysis of Products (TAP) reactor. Only lattice oxygen is involved in the oxidation reactions. Using isotopic labelled oxygen it is shown that two different active sites exist on the surface. On site A, which can be reoxidized faster by gas phase oxygen compared to site B, mainly CO is formed. On site B CO{sub 2} and acrolein as well as NO and N{sub 2}O in the presence of ammonia in the feed gas are formed and reoxidation mainly occurs with bulk lattice oxygen. (orig.)

1998-12-31

107

A study on the distribution of "1"3"7Cs in coastal waters of Tarapur from different nuclear facilities  

International Nuclear Information System (INIS)

A study on the distribution of "1"3"7Cs in coastal waters up to a distance of 15 km was undertaken for a decade (1995-2004) and observed that the activity has reduced by 15-20 fold. Statistical and trend analysis was carried out to resolve the contribution of different facilities at a distance of 5 km (north and south) from the discharge point by log normal probability analysis and found that at 5 km south, the median value of "1"3"7Cs due to TAPS and FRP discharges were 3.7 mBq/l and 1.50 mBq/l respectively. The observed levels of "1"3"7Cs are of no consequences from the point of view of dose to members of the public. (author)

2005-11-23

108

Study of radionuclide contributing to dose rates in 540 MWe plant environment  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport system, annulus gas system and moderator cover gas system were collected and analysed for the spectrometric analysis. This paper ...

2005-11-23

109

Radon concentrations in well water in Sichuan Province, China  

International Nuclear Information System (INIS)

There are 110 million people in Sichuan Province, China. Although most of the people in cities of Sichuan use river water, which contains low levels of radon, as potable water, people in countryside and in some communities of big cities still use well water as domestic consumption. This paper reports the radon concentrations in well water investigated in four cities, i.e. Chengdu, Chongqing, Leshan and Leijiang in Sichuan Province. Of the 80 wells investigated, the radon concentrations range from 3.5 to 181.6 KBqm"-"3. Of the four cities, Chongqing has the highest well water radon concentration with the average 49.6 #+-# 54.1 KBqm"-"3 and the greatest variation. The investigation in four cities showed that the radon concentrations in well water are much higher than that in tap-water. In Chongqing where there are complex geological structures, mainly granite stratum, for example, the average radon concentration in well water is 112 times higher than that in the ...

110

Multielement determination of heavy metals in water samples by continuous powder introduction microwave-induced plasma atomic emission spectrometry after preconcentration on activated carbon  

International Nuclear Information System (INIS)

A novel continuous powder introduction microwave-induced plasma atomic emission spectrometry method (CPI-MIP-AES) has been developed for trace determination of metals in ground and tap water samples after preconcentration on activated carbon. The experimental setup consisted of integrated rectangular cavity TE_1_0_1 and vertically positioned plasma torch. The technical arrangement of the sample introduction system has been designed based on the fluidized bed concept. The satisfactory signal stability required for sequential analysis was attained owing to the vertical plasma configuration, as well as the plasma gas flow rate compatibility with sample introduction flow rate. The elements of interest (Cd, Cu, Cr, Fe, Mn, Pb, Zn) were preconcentrated in a batch procedure at pH 8-8.5 after addition of activated carbon and then, after filtering and drying of the activated carbon suspension, introduced to the MIP by the CPI system. An enrichment factor of about 1000-fold ...

2005-03-31

111

Assessment of acute phase proteins and oxidative stress status of Nigerians using bleaching agents  

International Nuclear Information System (INIS)

The disruption of primary innate immune function of the epidermal layer of the skin accounts for the susceptibility of individuals using bleaching agents to localized or systemic infections. This subverted innate immunity in these people may lead to other pathological conditions. The resultant effects of skin bleaching and phagocytes activation in response to infections have not been studied in Nigerians using bleaching agents. The present study therefore assessed the levels of C-reactive protein (CRP), albumin, total antioxidant potential (TAP), total plasma peroxides (TPP), oxidative stress index (OSI) and malonaldehyde (MDA) in the users bleaching agents. Thirty (30) people who had used bleaching agents for average of 4.9 + 1.2 years participated in this study. They were recruited from various schools and markets within the city of Ibadan, Oyo State, Nigeria. Thirty apparently healthy staffs of University College Hospital Ibadan, Ibaadan, Nigeria, who had never ...

112

The static indentation behavior of composite sandwich panels with thin quasi-isotropic skins  

Science.gov (United States)

The quasi-static normal indentation of sandwich panels with quasi-isotropic laminated composite skins and honeycomb or foam cores, by spherical indentors, has been investigated using experiments and finite element analysis. The experimental program emphasized the effects of indentor size on the resulting load indentation responses, failure mechanisms in the skin and the core, and the measurement of contact areas between indentor and the target. The sandwich panels were indented up to the initiation of skin fracture and the resulting contact data was used to characterize contact power laws. A non-linear finite element model was developed based on the experimental observations to systematically explore the indentation behavior of diverse sandwich configurations and to investigate the contact pressure distributions. The finite element model was used as an experimental tool in the development of a simple non-dimensional semi-empirical model that was based on the Graeco-Latin-square ...

2001-01-01

113

Thermal analysis of spent fuel in shuttle station during dry transfer under abnormal cooling conditions for TAPS - 4  

International Nuclear Information System (INIS)

A pair of bundles is placed in a shuttle tube, which is enclosed by a carriage tube kept inside the Shuttle Transfer Station (STS). It takes about 90 minutes for the spent fuel bundles to travel from the reactor channel to Transfer Magazine (TM). Subsequently, the dry transfer operation takes about 4 minutes. An emergency air cooling flow rate of 600 m3/hr is supplied to cool the spent fuel bundles after they reach the STS, following lapse of 4 minutes of spent fuel dry transfer, in case the bundles are not submerged in the light water in STS. A thermal and hydraulic safety analysis has been done to estimate the maximum sheath temperature, if the spent fuel bundles are stuck at a location of 30 mm below the normal location aligned to the TM port. This position of the spent fuel will have least cooling from the emergency cooling airflow. At the same time, the shuttle tube carrying the spent fuel bundle is just above the water. From the analysis it has been concluded that peak clad ...

2006-11-13

114

Thermal analysis of spent fuel in rehearsal and emergency storage facility (RESF) under station blackout (SBO) in TAPS - 4  

International Nuclear Information System (INIS)

The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis was done for the modified RESF system configuration to estimate the flow rate through ...

2006-11-13

115

Synthesis of novel anode Li4Ti5O12/C with PAN as carbon source and its electrochemical performance  

British Library Electronic Table of Contents (United Kingdom)

A newly carbon-doped Lithium titanate (Li4Ti5O12/C) spinel-type composite material was routinely prepared by a simple solid-state reaction method using carbonization of polyacrylonitrile (PAN) as carbon source in an inert atmosphere. Impedance measurement shows that the resistance of the composite electrode is substantially lower than that of the pure one. Electrochemical performances of the prepared materials were investigated. Results indicate that the composite materials obtained with 10wt.% PAN shows relatively higher specific capacity, better cycling and higher rate performance. The first discharge specific capacity of 158mAhg^-^1, 138mAhg^-^1, and 121mAhg^-^1 were obtained at 0.2C rate, 1/3C rate, and 3C rate at room temperature, respectively. And it was also found that tap density o...

2011-01-01

116

Solar photochemistry and heterogeneous photocatalysis  

International Nuclear Information System (INIS)

The search for alternative energy supplies continues since the oil crisis of 1973. One energy vector is dihydrogen, H_2. Of the group VI hydrides, water has been the focus of most studies in harnessing solar energy and generating H_2. Two basic photochemical strategies have been employed: molecular photocatalytic systems, and semiconductor based photocatalytic systems. The results have not met with the euphoric expectations of the mid-1970's because of the difficulties encountered in H_2O splitting (E"0 S"2 "-/S = + 0.51 eV, NHE) is another vehicle tapped as a potential source of H_2. Heterogeneous photocatalysis utilizing semiconductor particulates and sunlight as the photon source has been successful with interesting quantum efficiencies. To this end, novel photocatalytic devices have been developed; one of these uses two coupled semiconductors to achieve vectorial displacement of the photogenerated reducing and oxidizing equivalents. An important area in which ...

117

Shielding analysis of TAPP-3,4 end-shield  

International Nuclear Information System (INIS)

This paper consists of shielding analysis of steel balls and water filled end shields of Indian Pressurized Heavy Water Reactors (PHWRs). The material composition inside lattice tube is entirely different neutronically as compared with the composition of end-shield. Due to variation of material composition in radial and axial directions and complex geometry, it is necessary to carry out 3-D analysis for reasonable prediction of neutron flux and gamma dose rates. In the present paper, shielding analysis of end-shield for 540 MWe PHWR has been carried out during reactor operating and shutdown conditions using Monte-Carlo code MCNP. Furthermore materials on the periphery and central portion of end shield are different. Therefore the analysis was carried out separately for annular portion and central portion of end shield. The dominating streaming paths through end shields were studied. Predictions compare well with the measurements at TAPS-4 reactor. (author)

2006-11-13

118

Radiological safety aspects associated with the handling, storage and disposal of self power neutron detectors in TAPS - 3 and 4  

International Nuclear Information System (INIS)

At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and are being stored in lead shielding inside spent fuel storage ...

2006-11-13

119

Prevention of pitting corrosion on copper tubes in central hot water supply systems by UV photochemical decomposition of residual chlorine  

Energy Technology Data Exchange (ETDEWEB)

After confirming that residual chlorine in tap water, which is regarded as one of the major cause of pitting corrosion, can be decomposed/removed by the irradiation of UV light, effect of dechlorinated water obtained based on this principle on the prevention of pitting corrosion, generation and growth, of the copper tubing was investigated by a corrosion test simulated the actual system in high buildings. (1) Low pressure type mercury lamp easily decompose/remove the residual chlorine. (2) If the dechlorinated water is supplied from the initial stage of copper tube usage, potential of the copper tube remains at the level of 100 mV/SCE and the generation of pitting corrosion is not observed. (3) Even when pitting corrosion is already found, switching to dechlorinated water in the midway reduces the potential of the copper tube down to 50 - 70 mV level, at the same time completely restricting the growth of the pitting corrosion. (15 figs, 9 refs)

1988-03-25

120

Preconcentration and determination of trace amounts of lead (II) as thenoyltrifluoroacetone complex with dibenzo-18-crown-6 by synergistic extraction and atomic absorption spectrometry  

Energy Technology Data Exchange (ETDEWEB)

A new method for the preconcentration and determination of trace amounts of lead at the {mu}g/L level in natural waters has been established based on the formation of the thenoyltrifluoroacetone (TTA) complex with dibenzo-18-crown-6 (DB18C6) by means of synergistic extraction and back-extraction combined with atomic absorption spectrometry (AAS). The effect of various factors (synergism with TTA and DB18C6, shaking time, preconcentration factor, composition of the extracted species, and foreign ions etc.) on the extraction and back-extraction of lead has been investigated in detail. The lead-TTA chelate in o-dichlorobenzene forms a stable adduct with DB18C6 as Pb(TTA){sub 2} DB18C6. The stability constant ({beta}) of the adduct determined by curve fitting method was log {beta} = 4.2. The amount of lead in natural waters such as tap water (Kanazawa University) and Kakehashi river (Komatsu City) determined by the present method was found to be 0.64 {+-} 0.02 {mu}g/L ...

1998-07-01

 
 
 
 
121

Physico Mechanical Properties of Irradiated Waste Rubber Cement Mortar  

International Nuclear Information System (INIS)

In the present study a partial replacement of aggregate with two different ratios of waste rubber (5%, 10%) with the addition of a constant ratio of rice husk ash (RHA), 5% was carried out. The hardened cement mortar used the optimum water of consistency. The specimens were molded into 1 inch cubic moulds .The specimens were first cured for 24 hours, at 100% relative humidity and then cured under tap water for 3, 7 and 28 days followed by irradiation at different doses of gamma irradiation namely 5 and 10 kGy. The physico-chemical and mechanical properties such as compressive strength, total porosity and bulk density were studied for the three types of specimens. The results showed that the values of the compressive strength, bulk density and chemically combined water of the blended cement mortar paste (OPC-RHA) increase ,while blended cement mortar paste with 5% RHA and 5, 10% waste rubber decrease. The results were confirmed by scanning electron microscopy and ...

122

Phenol by direct hydroxylation of benzene with nitrous oxide - role of surface oxygen species in the reaction pathways  

Energy Technology Data Exchange (ETDEWEB)

Transient experiments in a Temporal Analysis of Products (TAP) Reactor were performed to elucidate the role of surface oyxgen species in the oxidation of benzene to phenol on ZSM-5 type zeolites with nitrous oxide as a selective oxidant. It was shown by puls experiments with nitrous oxide that the mean lifetime of the generated surface oxygen species is between 0.2s at 500 C and about 4.2 s at 400 C. Afterwards the surface oxygen species desorb as molecular oxygen into the gas phase where total oxidation will take place if hydrocarbons are present. Dual puls experiments consisting of a nitrous oxide puls followed by a benzene puls allowed studying the reactivity of the surface oxygen species formed during the first puls. The observation of the phenol formation was impeded due to the strong sorption of phenol. Multipulse experiments were necessary to reach a pseudo steady state phenol yield. (orig.)

1998-12-31

123

Optimal security-constrained power scheduling by Benders decomposition  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a Benders decomposition approach to determine the optimal day-ahead power scheduling in a pool-organized power system, taking into account dispatch, network and security constraints. The study model considers the daily market and the technical constraints resolution as two different and consecutive processes. The daily market is solved in a first stage subject to economical criteria exclusively and then, the constraints solution algorithm is applied to this initial dispatch through the redispatching method. The Benders partitioning algorithm is applied to this constraints solution process to obtain an optimal secure power scheduling. The constraints solution includes a full AC network and security model to incorporate voltages magnitudes as they are a critical factor in some real power systems. The algorithm determines the active power committed to each generator so as to minimize the energy redispatch cost subject to dispatch, network and security constraints. The ...

2007-05-15

124

Modeling key cupola reactions: Behavior of carbon, silicon and manganese  

Energy Technology Data Exchange (ETDEWEB)

In the present study, models of key chemical processes governing the compositions of the tapped metal from the cupola on the basis of physico-chemical fundamentals have been developed. As evident from the literature survey, the investigations conducted in the past have focused their attention on one phenomenon at a time; for example, a particular chemical reaction, measurement of gas composition or the temperature distribution inside a cupola. Notwithstanding the importance of these studies and their contribution toward the understanding of cupola operation, mathematical models of key chemical processes and their interdependence must be investigated to obtain a complete insight into the various interlinked phenomena occurring inside a cupola. For example, the oxidation of the metallic charge leads to the formation of iron oxide which influences the final content of elements such as silicon, manganese and carbon. The processes considered in this study are oxidation ...

1991-01-01

125

Liquid zone system events at Wolsong Unit 2  

International Nuclear Information System (INIS)

On June 19, 1998, after the first annual outage, Wolsung Unit 2 was shutdown at a controlled rate due to the continuous instability of Liquid Zone Control level. Investigation revealed that the Liquid Zone Control level instability was caused by water condensed inside the helium lines, generated from the moistened helium flow, especially, inside the helium balance header feed and bleed valve lines. It was found that improper installation of the diaphragm type isolation valves and the drain valve tap could easily contain the water inside the lines and be destined to form water traps causing the balance header pressure oscillation. After the lines were dried, Liquid Zone Control level instability was almost vanished, and approached the allowable equilibrium state. As the reactor power was increased, however, the zone level instability increased again. In order to compensate for the excessive, the Bulk Power Control Gain (Kp) was reduced to provide a more stable ...

1998-09-07

126

Lead exposure via drinking water - unnecessary and avoidable; Bleiexposition ueber das Trinkwasser - unnoetig und vermeidbar  

Energy Technology Data Exchange (ETDEWEB)

Despite successful reduction of the general lead exposure, this heavy metal is still a matter of public concern due to the fact that associations with intellectual impairment or delayed puberty are found to correlate with very low lead blood concentrations. Lead in tap water is still an important contribution to lead exposure which may cause health risk for infants. Therefore, lead pipes should be completely sanitated by exchange against pipes made from more healthy materials. (orig.) [German] Trotz erfolgreicher Reduktion der allgemeinen Belastung ist Blei auch heute noch umweltmedizinisch relevant, weil es moeglicherweise bei niedrigeren als bisher angenommenen Belastungen gesundheitlich nachteilige Wirkungen, insbesondere waehrend der fruehkindlichen Entwicklung des Nervensystems, ausloest. Insbesondere Blei aus bleiernen Trinkwasserleitungen ist eine Belastung, die fuer Saeuglinge und Kleinkinder nach wie vor ein gesundheitliches Risiko darstellen kann. Solche ...

2003-07-01

127

Inventory of tritium concentration of waters in the Manche department; Inventaire des concentrations en tritium des eaux du Departement de La Manche  

Energy Technology Data Exchange (ETDEWEB)

For the inventory of water tritium concentration in the Manche department, it is the complementarity that animated the work opened during year 2001. To answer to a commune sensitivity such water quality, particularly drinking water at tap, the A.C.R.O. laboratory brought its know how to make and its technical means in the area of tritium analysis and the general council brought its know how to make and its logistics means in matter of sanitary control. This collaboration has allowed to supply an indication on the tritium content of the distribution waters of thirty of the most important cities of the department. Then, it allowed to inform on the radiological situation (in relation with the tritium presence) of coast waters and principal rivers waters. More than 160 controls have been realised between the months of march 2001 and february 2002. Only the tritium under the shape of tritiated water has been measured. The measures have been made by liquid scintillation ...

2007-07-01

128

Integrity assessment of 37 element fuel bundle of TAPS 3 and 4 reactor under beyond design basis accident condition  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station 3 and 4 is a 540 MWe Pressurized Heavy Water Reactor. It uses 37 - element natural Uranium dioxide (UO_2) fuel pellets encapsulated inside the cylindrical sheath and are welded to the end plate at each end. During an postulated accident in which part of the fuel bundle are exposed to very high temperature (no means of heat removal) and other are at lower temperature (coolant temperature) possibility of failure of end plate weld due of thermal stresses developed by these relative temperature cannot be ruled out. In this report an attempt is made to study behaviour of fuel bundle under different temperature loading. Modelling of 37 element fuel bundle was done in ANSYS FEM. System was analysed for various sets of temperature loading. The system was analysed for plasticity and creep as material nonlinearity. The total strain, creep strain and stress increase as the temperature increases in upper portion of fuel bundle and decrease with increase in temperature ...

2005-12-01

129

Financial resources for development. Capital markets in developing countries: a study on borrowing by developing countries in the emerging capital markets of the Middle East  

Energy Technology Data Exchange (ETDEWEB)

Private transfers of capital from the Organization of Petroleum Exporting Countries (OPEC) to developing countries are intended to complement private transfers from the Organization of Economic Cooperation and Development (OECD) by tapping the emerging capital markets in the Middle East. Developing countries will be able to diversify their borrowing and gain additional financing. The long-term investment of oil-producing countries will benefit and the pressures on the banking institutions to recycle funds will lessen. Middle East capital markets include international loans and international bonds. The history of the Kuwaiti dinar (KD) bond market, with its advantages for both investors and borrowers, illustrates the successful development of a capital market. Financial intermediation needs to be improved, however, if the Middle East is to become efficient enough to compete with the Euromarkets. Efficiency will require different measures and should reflect ...

1980-10-01

130

Dietary Cholesterol and Prostate Cancer Risk: Inhibition of prostate Cancer in Rats by the Administration of some Antioxidants  

International Nuclear Information System (INIS)

The present work was carried out to illuminate the relation between high cholesterol diet and incidence of prostate caner. Also, in this study, the effect of DHEA, selenium or oxygen therapy were tested in order to show to what extent they are valid to ameliorate the deleterious effects of prostate cancer. The obtained results revealed that prostate cancer caused a significant (p<0.01) elevation of TAP, PAP, PSA, total cholesterol, triglyceride, HDL-cholesterol and LDL-cholesterol and prostate COX-2, whereas, testosterone, free testosterone, DHEA-S, FT_4 and FT_3 were decreased significantly as compared with the corresponding levels in control rats in both normal and high cholesterol diet. Supplementation of DHEA, selenium or oxygen therapy ameliorated all variables recorded herein but, their values did not revert to normal. Any how, the results of this investigation showed that the above mentioned antioxidants possess potential benefits in lessening number of ...

2009-07-01

131

Determination of low level sulfides in environmental waters by automated gas dialysis/methylene blue colorimetry  

Energy Technology Data Exchange (ETDEWEB)

A sensitive and rapid automated method has been developed for the selective analysis of acid extractable sulfide in environmental samples by combining gas dialysis separation techniques with methylene blue detection procedures. Acid extractable sulfide is separated from the sample matrix by the gas dialysis membrane and subsequently trapped in a dilute sodium hydroxide receiving stream. This stream is reacted with N,N-dimethyl-p-phenylenediamine and ferric chloride to produce methylene blue which is then quantitated colorimetrically at 660 nm. For standards and nonturbid environmental samples, there is good agreement between the results obtained by this procedure and the standard methylene blue method. The effect of interferences on the accurate determination of sulfide by both methods was also examined and it was found that cupric ions significantly interfered with sulfide estimation. To obtain adequate sulfide recoveries in tap water and environmental samples ...

1990-01-01

132

An experimental integrated absorption heat pump effluent purification system. Pt. 1: Operating on water/lithium bromide solutions  

Energy Technology Data Exchange (ETDEWEB)

The merits of single stage absorption heat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorption heat pump effluent purification system (IAHPEPS) was built and operated with water-lithium bromide as a working mixture. This unit has been used to raise the temperature and hence, the vapour pressure of the impure water contained in one vessel, to the point where pure water vapour will distil from impure effluent solution (tap water or brine) and condense in a second vessel used to collect pure water. Pure effluent production rates of between 0.5 and 4.3 kg h{sup -1} were obtained. The actual coefficient of performance (COP{sub A}) and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, respectively. The results from the small scale systems indicate the likely results from industrial scale units which could be operated with low quality heat such as waste heat, solar or geothermal resources. ...

1999-05-01

133

Neutron activation analysis for determination of selected trace elements responsible for immunity in foodstuffs and water in egypt  

International Nuclear Information System (INIS)

Selenium (Se), zinc (Zn), magnesium (Mg), molybdenum (Mo) and vanadium (V) in 28 types of Egyptian common foodstuffs as well as drinking and irrigation water samples were determined using neutron activation analysis (NAA) and atomic absorption spectrometry (AAS). The samples were collected from 74 sites over 13 governorates as well as the Nile river, wells and tap water in the regions of the Nile Delta, Sinai, the east and west desert, and north and south Egypt. These trace elements were chosen according to international references, which show the close relationship of their deficiencies to immunity-related diseases. Calculation values of daily uptake per capita were made with the results of analysis. The results, as calculated per 100 g dry weight, showed that some Egyptian foods are rich in Se including such fish (0.94 #mu#g), sesame (0.88 #mu#g), beef meat (0.48 #mu#g), instant tea (0.42 #mu#g), mushroom (0.34 #mu#g) and eggs (0.3 #mu#g), whereas the vegetables ...

134

High Temperature Capacitor Development  

Energy Technology Data Exchange (ETDEWEB)

The absence of high-temperature electronics is an obstacle to the development of untapped energy resources (deep oil, gas and geothermal). US natural gas consumption is projected to grow from 22 trillion cubic feet per year (tcf) in 1999 to 34 tcf in 2020. Cumulatively this is 607 tcf of consumption by 2020, while recoverable reserves using current technology are 177 tcf. A significant portion of this shortfall may be met by tapping deep gas reservoirs. Tapping these reservoirs represents a significant technical challenge. At these depths, temperatures and pressures are very high and may require penetrating very hard rock. Logistics of supporting 6.1 km (20,000 ft) drill strings and the drilling processes are complex and expensive. At these depths up to 50% of the total drilling cost may be in the last 10% of the well depth. Thus, as wells go deeper it is increasingly important that drillers are able to monitor conditions down-hole such as ...

2009-06-30

135

Turning wood residues into wood revenues  

Energy Technology Data Exchange (ETDEWEB)

Ensyn is a profitable commercial company which derives its revenues from the conversion of wood residues into liquid biofuel and chemicals. The technology, Rapid Thermal Processing (RTP{sup (TM)})is based on extremely fast ``cracking`` of biomass which results in light liquid yields exceeding 70% by weight, from wood. Whether producing chemicals or liquid biofuel, the RTP plant is configured identically and operated essentially in the same mode. Chemicals production simply allows economical production to occur at a lower plant capacity, as low as 2 tonnes/day, than is feasible for a dedicated fuel plant (typically greater than 100 tonnes/day). Ensyn has developed the commercialisation of RTP{sup TM} from bench to industrial scale in 10 years. A variety of crative funding initiatives in the early years allowed for capital to be raised for R and D without the loss of intellectual property (IP). The transition years of technology demonstration, prior to full commercialisation, were funded ...

1996-06-01

136

Surface Roughness of Stainless Steel Bender Mirrors for FocusingSoft X-rays  

Energy Technology Data Exchange (ETDEWEB)

We have used polished stainless steel as a mirror substrate to provide focusing of soft x-rays in grazing incidence reflection. The substrate is bent to an elliptical shape with large curvature and high stresses in the substrate require a strong elastic material. Conventional material choices of silicon or of glass will not withstand the stress required. The use of steel allows the substrates to be polished and installed flat, using screws in tapped holes. The ultra-high-vacuum bender mechanism is motorized and computer controlled. These mirrors are used to deliver focused beams of soft x-rays onto the surface of a sample for experiments at the Advanced Light Source (ALS). They provide an illumination field that can be as small as the mirror demagnification allows, for localized study, and can be enlarged, under computer control,for survey measurements over areas of the surface up to several millimeters. The critical issue of the quality of the steel surface, ...

2005-10-11

137

Preliminary delineation of natural geochemical reactions, Snake River Plain aquifer system, Idaho National Engineering Laboratory and vicinity, Idaho  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Geological Survey, in cooperation with the U.S. Department of Energy, is conducting a study to determine the natural geochemistry of the Snake River Plain aquifer system at the Idaho National Engineering Laboratory (INEL), Idaho. As part of this study, a group of geochemical reactions that partially control the natural chemistry of ground water at the INEL were identified. Mineralogy of the aquifer matrix was determined using X-ray diffraction and thin-section analysis and theoretical stabilities of the minerals were used to identify potential solid-phase reactants and products of the reactions. The reactants and products that have an important contribution to the natural geochemistry include labradorite, olivine, pyroxene, smectite, calcite, ferric oxyhydroxide, and several silica phases. To further identify the reactions, analyses of 22 representative water samples from sites tapping the Snake River Plain aquifer system were used to determine the ...

1997-05-01

138

Performance improvement of pasted nickel electrodes with an addition of ball-milled nickel hydroxide powder  

Energy Technology Data Exchange (ETDEWEB)

Spherical {beta}-Ni(OH){sub 2} was modified by a low-cost method of normal ball milling (NBM), and the physical properties of both ball-milled and un-milled Ni(OH){sub 2} were characterized by transmission electron microscopy, specific surface area, particle size distribution and X-ray diffraction. It was found that NBM could obviously increase the surface area, decrease the particle and crystallite size, and reduce the crystallinity of {beta}-Ni(OH){sub 2}, which were advantageous to the improvement of the electrochemical activity of Ni(OH){sub 2}. NBM also lowered the packing density and flowability of Ni(OH){sub 2}, as revealed by the measurements of tapping density and angle of repose. Electrochemical performances of pasted nickel electrodes with an addition of ball-milled Ni(OH){sub 2} to spherical Ni(OH){sub 2} as the active material were investigated, and were compared with those of the pure spherical Ni(OH){sub 2} electrodes. Charge/discharge tests showed ...

2006-09-15

139

Naval Petroleum and Oil Shale Reserves. Annual report of operations, fiscal year 1983  

Energy Technology Data Exchange (ETDEWEB)

Naval Petroleum Reserve No. 1 (NPR-1) in California and Naval Petroleum Reserve No. 3 (NPR-3) in Wyoming continued to be operated at their maximum efficient rates of production during FY 1983. The Government-owned portion of Naval Petroleum Reserve No. 2 in California continued to be leased to private operators as it has been for over 50 years, with the Government receiving a royalty share of production from the leases. All of the Government's share of crude oil produced at the Petroleum Reserves during FY 1983 was sold to the Department of Defense, while natural gas and natural gas liquids were sold competitively on the open market. FY 1983 revenues from the three Naval Petroleum Reserves totaled over $1.5 billion in general receipts and Windfall Profit Taxes. Program expenditures totaled approximately $220 million. The drilling of new wells continued to be an important factor in maintaining the production of NPR-1 and NPR-3 at maximum efficient rates, and it is expected that ...

1983-01-01

140

Ion-exchange scheme for selective removal of gadolinium nitrate from the moderator system of 540 MWe Indian PHWRs using macroporous strong acid cation and macro porous weak base anion resins  

International Nuclear Information System (INIS)

Gadolinium nitrate has been employed in Indian nuclear reactors for the first time as soluble neutron poison in the heavy water moderators of the 540 MWe PHWRs TAPS 3 and 4, as a fast acting secondary shut down system (SDS-2); and also for reactivity shim. For this purpose, the moderator purification system is currently equipped with special ion-exchange columns/schemes, developed by present authors. However, for gadolinium removal from moderator in the post SDS-2 scenario, the two stage ion-exchange - cation bed operation followed by mixed bed operation - results in low pH conditions persisting in the moderator for a few hours, which gives rise to certain operational problems. The present paper describes a mixed bed ion-exchange scheme employing macro-porous strong acid cation and macro-porous weak base anion resins, which has been developed to eliminate acidic conditions and gives a better pH control. The cation to anion capacity ratio in the mixed bed was ...

2008-12-01

 
 
 
 
141

Investigations on process design and fuel substitution in a cokeless, natural-gas-fuelled cupola furnace; Untersuchung zur Prozessgestaltung und Brennstoffsubstitution an einem kokslosen erdgasbefeuerten Kupolofen (KLKO)  

Energy Technology Data Exchange (ETDEWEB)

A process model is presented and used for identifying options for controlling the cupola furnace process and for investigating natural gas substitutes. Fuel substitution will affect temperature curves (i.e. tapping temperatures and melting capacity), outlet temperatures and gas mass flow out of the preheating zone. The contribution presents several process variations to overcome these problems and compares them with the natural gas process. [German] Mit dem Prozessmodell werden zunaechst Moeglichkeiten der Steuerung von Abstichtemperatur und Schmelzleistung, insbesondere unter Beruecksichtigung der Schrottqualitaet (spezifische Oberflaeche a{sub G}), untersucht. Es wird gezeigt, dass das Prozessmodell die Ergebnisse aus der Praxis wiedergibt. Daran anschliessend wird mit dem Prozessmodell die Substitution von Erdgas durch minderwertige Gase untersucht (Brennstoffsubstitution, Ressourcenschonung). Durch die Brennstoffsubstitution veraendern sich die ...

2001-07-01

142

Gadolinium removal from the moderator system of TAPP - 3 using the three layer bed  

International Nuclear Information System (INIS)

Nitric acid leaching from the weak base anion (WBA) exchanger had been evaluated and based on this a 5% mixture of nitric acid loaded weak base anion exchanger with fresh weak base anion exchanger (NLWBA) at the bottom of the ion exchange column has been devised to maintain an outlet pH in the range of 5.0 to 5.5 during Gd removal from the moderator system of TAPP - 3 and 4. A three layered bed had been constituted wherein strong acid cation (SAC) exchanger is placed as the top layer while a mixed bed of SAC and WBA or pure WBA is used as the middle layer and the 5% NLWBA was used as the bottom most layer. This bed configuration would result in an iso-pH regime in the moderator system during the Gd removal along with quantitative removal of Gd. Two three-layer bed columns were prepared at TAPS - 3 and 4 in July 07. The resin was loaded in batches and after preparing the column, the column was deuterated with heavy water (> 99.75 % w/w) at a steady flow rate of ...

2008-12-01

143

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible areas and out side the RE containment, the travel time for the ...

2006-11-13

144

Determination of endocrine-disrupting compounds in water by carbon nanotubes solid-phase microextraction fiber coupled online with high performance liquid chromatography.  

Science.gov (United States)

The commercial solid phase microextraction (SPME) fibers are not stable enough in organic solvent and tend to swell and strip off from the silica fiber in the high performance liquid chromatography (HPLC) mobile phase, and therefore the application of SPME coupled online with HPLC is limited. In this study, an SPME fiber coated with single walled carbon nanotubes (SWCNTs), prepared by means of electrophoretic deposition, was coupled on line to HPLC for the determination of four endocrine-disrupting compounds, i.e. bisphenol A (BPA), estrone (E(1)), 17?-ethynylestradiol (EE(2)) and octylphenol (OP), in aqueous samples. The results showed that the SWCNTs coating on the prepared fiber did not swell and strip off from the platinum fiber throughout the experiment, thus indicating a high resistance to the HPLC mobile phase, the mixture of water and acetonitrile. The SWCNTs fiber had similar (for OP) or higher (for BPA, EE(2) and E(1)) extraction efficiencies than the commonly used ...

2011-07-27

145

Design and operating experience of a 40 MW, highly-stabilized power supply  

Energy Technology Data Exchange (ETDEWEB)

Four 10 MW, highly-stabilized power supply modules have been installed at the National High Magnetic Field Laboratory in Tallahassee, FL, to energize water-cooled, resistive, high-field research magnets. The power supply modules achieve a long term current stability if 10 ppM over a 12 h period with a short term ripple and noise variation of <10 ppM over a time period of one cycle. The power supply modules can operate independently, feeding four separate magnets, or two, three or four modules can operate in parallel. Each power supply module consists of a 12.5 kV vacuum circuit breaker, two three-winding, step-down transformers, a 24-pulse rectifier with interphase reactors, and a passive and an active filter. Two different transformer tap settings allow rated dc supply output voltages of 400 and 500 V. The rated current of a supply module is 17 kA and each supply module has a one-hour overload capability of 20 kA. The isolated output terminals of each power ...

1995-07-01

146

Characterization of VPO ammoxidation catalysts by in situ methods  

Energy Technology Data Exchange (ETDEWEB)

In-situ methods are well known as powerful tools in studying catalyst formation processes, their solid state properties under working conditions and the interaction with the feed, intermediates and products to reveal reaction mechanisms. This paper gives a short overview on results of intense studies using in-situ techniques to reveal VPO catalyst generation processes, interaction of educts, intermediates and products with VPO catalyst surfaces and mechanistic insights. Catalytic data of the ammoxidation of toluene on different VPOs complete these findings. The precursor-catalyst transformation processes were preferently investigated by in-situ XRD, in-situ Raman and in-situ ESR spectroscopy. The interaction of aromatic molecules and intermediates, resp., and VPO solid surfaces was followed by in-situ ESR and in-situ FTIR spectroscopy. Mechanistic information was mainly obtained using in-situ FTIR spectroscopy and the temporal-analysis-of-products (TAP) technique. ...

1998-12-31

147

Boiling heat transfer in compact heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Small circular and noncircular channels are representative of flow passages in compact evaporators and condensers. This paper describes results of an experimental study on heat transfer to the flow boiling of refrigerant- 12 in a small circular tube of diameter = 2.46 mm. The objective of the study was to assess the effect of channel size on the heat transfer coefficient and to obtain additional insights relative to the heat transfer mechanisms. The flow channel was made of brass and had an overall length of 0.9 m. The channel wall was electrically heated, and temperatures were measured on the channel wall and in the bulk fluid stream. Voltage taps were located at the same axial locations as the stream thermocouples to allow testing over an exit quality range of 0.21 to 0.94 and a large range of mass flux (63 to 832 kg/m{sup 2}s) and heat flux (2.5 to 59 kW/m{sup 2}). Saturation pressure was nearly constant, averaging 0.82 MPa for most of the testing; a few test ...

1994-12-31

148

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for the feed water becomes very long resulting ...

2005-11-23

149

A complete algorithm for synthesizing modular fixtures for polygonal parts  

Energy Technology Data Exchange (ETDEWEB)

Commercially-available nuclear fixturing systems typically include a square lattice of tapped and bushed holes with precision locating and clamping elements that can be rigidly attached to the lattice using dowel pins or expanding mandrels. Currently, human expertise is required to synthesize a suitable arrangements of these elements to hold a given part. Besides being time consuming, if the set of alternatives is not systematically explored, the designer may fail to find an acceptable fixture or may settle upon a suboptimal fixture. We consider a class of modular fixtures that prevent a part from translating or rotting in the plane using four point contacts on the part`s boundary. These fixtures are based on three round locators, each centered on a lattice point, and one translating clamp. We present an algorithm that accepts a polygonal part shape as input and synthesizes the set of all fixture designs that achieve form closure for the given part. The algorithm ...

1993-11-01

150

Assessment and Forecasting Natural Gas Reserve Appreciation in the Gulf Coast Basin  

Energy Technology Data Exchange (ETDEWEB)

Reserve appreciation, also called reserve growth, is the increase in the estimated ultimate recovery (the sum of year end reserves and cumulative production) from fields subsequent to discovery from extensions, infield drilling, improved recovery of in-place resources, new pools, and intrapool completions. In recent years, reserve appreciation has become a major component of total U.S. annual natural gas reserve additions. Over the past 15 years, reserve appreciation has accounted for more than 80 percent of all annual natural gas reserve additions in the U.S. lower 48 states (Figure 1). The rise of natural gas reserve appreciation basically came with the judgment that reservoirs were much more geologically complex than generally thought, and they hold substantial quantities of natural gas in conventionally movable states that are not recovered by typical well spacing and vertical completion practices. Considerable evidence indicates that many reservoirs show significant geological ...

1997-10-01

151

Effectively managing nuclear risk through human performance improvement  

International Nuclear Information System (INIS)

Full text: The US commercial nuclear industry has just completed an outstanding decade of plant performance. Safety levels and electric production are at unprecedented high levels and continue to exceed even high industry goals. Nuclear energy continues to keep the highest priority on performance improvement programs and highly trained/qualified people that maintain its record setting safety and reliability of operations. While the industry has maintained a consistently high level of performance, the advent of deregulation and the consolidation of NPP ownership, as well as the current climate of concern about both rising energy costs and availability of power, has raised the standard for nuclear energy's level of competitiveness in today's market place. The resulting challenge is how to more effectively manage risk and improve performance even further in a generally high performing organization. Newer technology and more training by themselves are not the answer. Rather, the answer ...