WorldWideScience

Sample records for circumferential endocardial extent

  1. Increased fetal endocardial echogenicity mimicking endocardial fibroelastosis following maternal organophosphorus poisoning and its complete regression in utero

    International Nuclear Information System (INIS)

    Balakumar, Karippaliyil; Misha, Kannan; Milind, Karippaliyil

    2013-01-01

    Fetal endocardial fibroelastosis (EFE) has been diagnosed by antenatal ultrasonography in the past few years. A typical case of isolated endocardial fibroelastosis is illustrated here, in a fetus of 22 weeks of gestational age exposed to maternal organophosphorus poisoning at 20 weeks. No other structural cardiac or other systemic anomalies were detected in this fetus. The abnormal fetal echocardiographic features mimicking endocardial fibroelastosis completely regressed after 14 weeks and a normal full-term baby was delivered. Postnatal echocardiogram showed normal cardiac parameters. The diagnostic features mimicking EFE following maternal organophosphorus poisoning at 20 weeks of gestational age and the subsequent complete reversal of these changes after 14 weeks of diagnosis are reported for the first time in the literature

  2. File list: Unc.CDV.50.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.CDV.50.AllAg.Endocardial_cells hg19 Unclassified Cardiovascular Endocardial cel...ls http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.CDV.50.AllAg.Endocardial_cells.bed ...

  3. File list: DNS.CDV.05.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.CDV.05.AllAg.Endocardial_cells hg19 DNase-seq Cardiovascular Endocardial cells ...http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.CDV.05.AllAg.Endocardial_cells.bed ...

  4. File list: His.CDV.20.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.CDV.20.AllAg.Endocardial_cells hg19 Histone Cardiovascular Endocardial cells ht...tp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.CDV.20.AllAg.Endocardial_cells.bed ...

  5. File list: DNS.CDV.20.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.CDV.20.AllAg.Endocardial_cells hg19 DNase-seq Cardiovascular Endocardial cells ...http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.CDV.20.AllAg.Endocardial_cells.bed ...

  6. File list: DNS.CDV.10.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.CDV.10.AllAg.Endocardial_cells hg19 DNase-seq Cardiovascular Endocardial cells ...http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.CDV.10.AllAg.Endocardial_cells.bed ...

  7. File list: Unc.CDV.05.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.CDV.05.AllAg.Endocardial_cells hg19 Unclassified Cardiovascular Endocardial cel...ls http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.CDV.05.AllAg.Endocardial_cells.bed ...

  8. File list: DNS.CDV.50.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.CDV.50.AllAg.Endocardial_cells hg19 DNase-seq Cardiovascular Endocardial cells ...http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.CDV.50.AllAg.Endocardial_cells.bed ...

  9. File list: Unc.CDV.20.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.CDV.20.AllAg.Endocardial_cells hg19 Unclassified Cardiovascular Endocardial cel...ls http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.CDV.20.AllAg.Endocardial_cells.bed ...

  10. File list: His.CDV.05.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.CDV.05.AllAg.Endocardial_cells hg19 Histone Cardiovascular Endocardial cells ht...tp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.CDV.05.AllAg.Endocardial_cells.bed ...

  11. File list: His.CDV.50.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.CDV.50.AllAg.Endocardial_cells hg19 Histone Cardiovascular Endocardial cells ht...tp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.CDV.50.AllAg.Endocardial_cells.bed ...

  12. File list: His.CDV.10.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.CDV.10.AllAg.Endocardial_cells hg19 Histone Cardiovascular Endocardial cells ht...tp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.CDV.10.AllAg.Endocardial_cells.bed ...

  13. File list: Pol.CDV.05.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.CDV.05.AllAg.Endocardial_cells hg19 RNA polymerase Cardiovascular Endocardial c...ells http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.CDV.05.AllAg.Endocardial_cells.bed ...

  14. File list: Pol.CDV.50.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.CDV.50.AllAg.Endocardial_cells hg19 RNA polymerase Cardiovascular Endocardial c...ells http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.CDV.50.AllAg.Endocardial_cells.bed ...

  15. File list: Pol.CDV.20.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.CDV.20.AllAg.Endocardial_cells hg19 RNA polymerase Cardiovascular Endocardial c...ells http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.CDV.20.AllAg.Endocardial_cells.bed ...

  16. File list: Pol.CDV.10.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.CDV.10.AllAg.Endocardial_cells hg19 RNA polymerase Cardiovascular Endocardial c...ells http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.CDV.10.AllAg.Endocardial_cells.bed ...

  17. File list: Oth.CDV.05.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CDV.05.AllAg.Endocardial_cells hg19 TFs and others Cardiovascular Endocardial c...ells http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.CDV.05.AllAg.Endocardial_cells.bed ...

  18. File list: Oth.CDV.10.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CDV.10.AllAg.Endocardial_cells hg19 TFs and others Cardiovascular Endocardial c...ells http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.CDV.10.AllAg.Endocardial_cells.bed ...

  19. File list: Oth.CDV.50.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CDV.50.AllAg.Endocardial_cells hg19 TFs and others Cardiovascular Endocardial c...ells http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.CDV.50.AllAg.Endocardial_cells.bed ...

  20. File list: Oth.CDV.20.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CDV.20.AllAg.Endocardial_cells hg19 TFs and others Cardiovascular Endocardial c...ells http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.CDV.20.AllAg.Endocardial_cells.bed ...

  1. File list: ALL.CDV.05.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.CDV.05.AllAg.Endocardial_cells hg19 All antigens Cardiovascular Endocardial cel...ls DRX014674 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.CDV.05.AllAg.Endocardial_cells.bed ...

  2. File list: ALL.CDV.10.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.CDV.10.AllAg.Endocardial_cells hg19 All antigens Cardiovascular Endocardial cel...ls DRX014674 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.CDV.10.AllAg.Endocardial_cells.bed ...

  3. File list: ALL.CDV.50.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.CDV.50.AllAg.Endocardial_cells hg19 All antigens Cardiovascular Endocardial cel...ls DRX014674 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.CDV.50.AllAg.Endocardial_cells.bed ...

  4. File list: ALL.CDV.20.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.CDV.20.AllAg.Endocardial_cells hg19 All antigens Cardiovascular Endocardial cel...ls DRX014674 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.CDV.20.AllAg.Endocardial_cells.bed ...

  5. File list: InP.CDV.10.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.10.AllAg.Endocardial_cells hg19 Input control Cardiovascular Endocardial ce...lls http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.10.AllAg.Endocardial_cells.bed ...

  6. File list: InP.CDV.50.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.50.AllAg.Endocardial_cells hg19 Input control Cardiovascular Endocardial ce...lls http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.50.AllAg.Endocardial_cells.bed ...

  7. File list: InP.CDV.20.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.20.AllAg.Endocardial_cells hg19 Input control Cardiovascular Endocardial ce...lls http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.20.AllAg.Endocardial_cells.bed ...

  8. File list: InP.CDV.05.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.05.AllAg.Endocardial_cells hg19 Input control Cardiovascular Endocardial ce...lls http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.05.AllAg.Endocardial_cells.bed ...

  9. File list: NoD.CDV.10.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.CDV.10.AllAg.Endocardial_cells hg19 No description Cardiovascular Endocardial c...ells DRX014674 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.CDV.10.AllAg.Endocardial_cells.bed ...

  10. File list: NoD.CDV.05.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.CDV.05.AllAg.Endocardial_cells hg19 No description Cardiovascular Endocardial c...ells DRX014674 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.CDV.05.AllAg.Endocardial_cells.bed ...

  11. File list: NoD.CDV.20.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.CDV.20.AllAg.Endocardial_cells hg19 No description Cardiovascular Endocardial c...ells DRX014674 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.CDV.20.AllAg.Endocardial_cells.bed ...

  12. File list: NoD.CDV.50.AllAg.Endocardial_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.CDV.50.AllAg.Endocardial_cells hg19 No description Cardiovascular Endocardial c...ells DRX014674 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.CDV.50.AllAg.Endocardial_cells.bed ...

  13. Quantitative assessment of regional left ventricular motion using endocardial landmarks

    NARCIS (Netherlands)

    C.J. Slager (Cornelis); T.E.H. Hooghoudt (Ton); P.W.J.C. Serruys (Patrick); J.C.H. Schuurbiers (Johan); J.H.C. Reiber (Johan); G.T. Meester (Geert); P.D. Verdouw (Pieter); P.G. Hugenholtz (Paul)

    1986-01-01

    textabstractIn this study the hypothesis is tested that the motion pattern of small anatomic landmarks, recognizable at the left ventricular endocardial border in the contrast angiocardiogram, reflects the motion of the endocardial wall. To verify this, minute metal markers were inserted in the

  14. Localization of endocardial ectopic activity by means of noninvasive endocardial surface current density reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Lai Dakun; Liu Chenguang; Eggen, Michael D; He Bin [Department of Biomedical Engineering, University of Minnesota, MN (United States); Iaizzo, Paul A, E-mail: binhe@umn.edu [Department of Surgery, University of Minnesota, MN (United States)

    2011-07-07

    Localization of the source of cardiac ectopic activity has direct clinical benefits for determining the location of the corresponding ectopic focus. In this study, a recently developed current-density (CD)-based localization approach was experimentally evaluated in noninvasively localizing the origin of the cardiac ectopic activity from body-surface potential maps (BSPMs) in a well-controlled experimental setting. The cardiac ectopic activities were induced in four well-controlled intact pigs by single-site pacing at various sites within the left ventricle (LV). In each pacing study, the origin of the induced ectopic activity was localized by reconstructing the CD distribution on the endocardial surface of the LV from the measured BSPMs and compared with the estimated single moving dipole (SMD) solution and precise pacing site (PS). Over the 60 analyzed beats corresponding to ten pacing sites (six for each), the mean and standard deviation of the distance between the locations of maximum CD value and the corresponding PSs were 16.9 mm and 4.6 mm, respectively. In comparison, the averaged distance between the SMD locations and the corresponding PSs was slightly larger (18.4 {+-} 3.4 mm). The obtained CD distribution of activated sources extending from the stimulus site also showed high consistency with the endocardial potential maps estimated by a minimally invasive endocardial mapping system. The present experimental results suggest that the CD method is able to locate the approximate site of the origin of a cardiac ectopic activity, and that the distribution of the CD can portray the propagation of early activation of an ectopic beat.

  15. Unipolar atrial electrogram morphology from an epicardial and endocardial perspective.

    Science.gov (United States)

    van der Does, Lisette J M E; Knops, Paul; Teuwen, Christophe P; Serban, Corina; Starreveld, Roeliene; Lanters, Eva A H; Mouws, Elisabeth M J P; Kik, Charles; Bogers, Ad J J C; de Groot, Natasja M S

    2018-02-22

    Endo-epicardial asynchrony (EEA) and the interplay between the endocardial and epicardial layers could be important in the pathophysiology of atrial arrhythmias. The morphologic differences between epicardial and endocardial atrial electrograms have not yet been described, and electrogram morphology may hold information about the presence of EEA. The purpose of this study was to directly compare epicardial to endocardial unipolar electrogram morphology during sinus rhythm (SR) and to evaluate whether EEA contributes to electrogram fractionation by correlating fractionation to spatial activation patterns. In 26 patients undergoing cardiac surgery, unipolar electrograms were simultaneously recorded from the epicardium and endocardium at the inferior, middle, and superior right atrial (RA) free wall during SR. Potentials were analyzed for epi-endocardial differences in local activation time, voltage, RS ratio, and fractionation. The surrounding and opposite electrograms of fractionated deflections were evaluated for corresponding local activation times in order to determine whether fractionation originated from EEA. The superior RA was predisposed to delayed activation, EEA, and fractionation. Both epicardial and endocardial electrograms demonstrated an S-predominance. Fractionation was mostly similar between the 2 sides; however, incidentally deflections up to 4 mV on 1 side could be absent on the other side. Remote activation was responsible for most fractionated deflections (95%) in SR, of which 4% could be attributed to EEA. Local epi-endocardial differences in electrogram fractionation occur occasionally during SR but will likely increase during arrhythmias due to increasing EEA and (functional) conduction disorders. Electrogram fractionation can originate from EEA, and this study demonstrated that unipolar electrogram fractionation can potentially identify EEA. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  16. Endocardial Pacemaker Implantation in Neonates and Infants

    Directory of Open Access Journals (Sweden)

    Canan Ayabakan

    2006-04-01

    Full Text Available Transvenous pacemaker lead implantation is the preferred method of pacing in adult patients. Lead performance and longevity are superior and the implantation approach can be performed under local anaesthetic with a very low morbidity. In children, and especially in neonates and infants, the epicardial route was traditionally chosen until the advent of smaller generators and lead implantation techniques that allowed growth of the child without lead displacement. Endocardial implantation is not universally accepted, however, as there is an incidence of venous occlusion of the smaller veins of neonates and infants with concerns for loss of venous access in the future. Growing experience with lower profile leads, however, reveals that endocardial pacing too can be performed with low morbidity and good long-term results in neonates and infants.

  17. Endocardial to myocardial notch-wnt-bmp axis regulates early heart valve development.

    Directory of Open Access Journals (Sweden)

    Yidong Wang

    Full Text Available Endocardial to mesenchymal transformation (EMT is a fundamental cellular process required for heart valve formation. Notch, Wnt and Bmp pathways are known to regulate this process. To further address how these pathways coordinate in the process, we specifically disrupted Notch1 or Jagged1 in the endocardium of mouse embryonic hearts and showed that Jagged1-Notch1 signaling in the endocardium is essential for EMT and early valvular cushion formation. qPCR and RNA in situ hybridization assays reveal that endocardial Jagged1-Notch1 signaling regulates Wnt4 expression in the atrioventricular canal (AVC endocardium and Bmp2 in the AVC myocardium. Whole embryo cultures treated with Wnt4 or Wnt inhibitory factor 1 (Wif1 show that Bmp2 expression in the AVC myocardium is dependent on Wnt activity; Wnt4 also reinstates Bmp2 expression in the AVC myocardium of endocardial Notch1 null embryos. Furthermore, while both Wnt4 and Bmp2 rescue the defective EMT resulting from Notch inhibition, Wnt4 requires Bmp for its action. These results demonstrate that Jagged1-Notch1 signaling in endocardial cells induces the expression of Wnt4, which subsequently acts as a paracrine factor to upregulate Bmp2 expression in the adjacent AVC myocardium to signal EMT.

  18. Simultaneous epicardial and noncontact endocardial mapping of the canine right atrium: simulation and experiment.

    Science.gov (United States)

    Sabouri, Sepideh; Matene, Elhacene; Vinet, Alain; Richer, Louis-Philippe; Cardinal, René; Armour, J Andrew; Pagé, Pierre; Kus, Teresa; Jacquemet, Vincent

    2014-01-01

    Epicardial high-density electrical mapping is a well-established experimental instrument to monitor in vivo the activity of the atria in response to modulations of the autonomic nervous system in sinus rhythm. In regions that are not accessible by epicardial mapping, noncontact endocardial mapping performed through a balloon catheter may provide a more comprehensive description of atrial activity. We developed a computer model of the canine right atrium to compare epicardial and noncontact endocardial mapping. The model was derived from an experiment in which electroanatomical reconstruction, epicardial mapping (103 electrodes), noncontact endocardial mapping (2048 virtual electrodes computed from a 64-channel balloon catheter), and direct-contact endocardial catheter recordings were simultaneously performed in a dog. The recording system was simulated in the computer model. For simulations and experiments (after atrio-ventricular node suppression), activation maps were computed during sinus rhythm. Repolarization was assessed by measuring the area under the atrial T wave (ATa), a marker of repolarization gradients. Results showed an epicardial-endocardial correlation coefficients of 0.80 and 0.63 (two dog experiments) and 0.96 (simulation) between activation times, and a correlation coefficients of 0.57 and 0.46 (two dog experiments) and 0.92 (simulation) between ATa values. Despite distance (balloon-atrial wall) and dimension reduction (64 electrodes), some information about atrial repolarization remained present in noncontact signals.

  19. Simultaneous epicardial and noncontact endocardial mapping of the canine right atrium: simulation and experiment.

    Directory of Open Access Journals (Sweden)

    Sepideh Sabouri

    Full Text Available Epicardial high-density electrical mapping is a well-established experimental instrument to monitor in vivo the activity of the atria in response to modulations of the autonomic nervous system in sinus rhythm. In regions that are not accessible by epicardial mapping, noncontact endocardial mapping performed through a balloon catheter may provide a more comprehensive description of atrial activity. We developed a computer model of the canine right atrium to compare epicardial and noncontact endocardial mapping. The model was derived from an experiment in which electroanatomical reconstruction, epicardial mapping (103 electrodes, noncontact endocardial mapping (2048 virtual electrodes computed from a 64-channel balloon catheter, and direct-contact endocardial catheter recordings were simultaneously performed in a dog. The recording system was simulated in the computer model. For simulations and experiments (after atrio-ventricular node suppression, activation maps were computed during sinus rhythm. Repolarization was assessed by measuring the area under the atrial T wave (ATa, a marker of repolarization gradients. Results showed an epicardial-endocardial correlation coefficients of 0.80 and 0.63 (two dog experiments and 0.96 (simulation between activation times, and a correlation coefficients of 0.57 and 0.46 (two dog experiments and 0.92 (simulation between ATa values. Despite distance (balloon-atrial wall and dimension reduction (64 electrodes, some information about atrial repolarization remained present in noncontact signals.

  20. Simultaneous Epicardial and Noncontact Endocardial Mapping of the Canine Right Atrium: Simulation and Experiment

    Science.gov (United States)

    Sabouri, Sepideh; Matene, Elhacene; Vinet, Alain; Richer, Louis-Philippe; Cardinal, René; Armour, J. Andrew; Pagé, Pierre; Kus, Teresa; Jacquemet, Vincent

    2014-01-01

    Epicardial high-density electrical mapping is a well-established experimental instrument to monitor in vivo the activity of the atria in response to modulations of the autonomic nervous system in sinus rhythm. In regions that are not accessible by epicardial mapping, noncontact endocardial mapping performed through a balloon catheter may provide a more comprehensive description of atrial activity. We developed a computer model of the canine right atrium to compare epicardial and noncontact endocardial mapping. The model was derived from an experiment in which electroanatomical reconstruction, epicardial mapping (103 electrodes), noncontact endocardial mapping (2048 virtual electrodes computed from a 64-channel balloon catheter), and direct-contact endocardial catheter recordings were simultaneously performed in a dog. The recording system was simulated in the computer model. For simulations and experiments (after atrio-ventricular node suppression), activation maps were computed during sinus rhythm. Repolarization was assessed by measuring the area under the atrial T wave (ATa), a marker of repolarization gradients. Results showed an epicardial-endocardial correlation coefficients of 0.80 and 0.63 (two dog experiments) and 0.96 (simulation) between activation times, and a correlation coefficients of 0.57 and 0.46 (two dog experiments) and 0.92 (simulation) between ATa values. Despite distance (balloon-atrial wall) and dimension reduction (64 electrodes), some information about atrial repolarization remained present in noncontact signals. PMID:24598778

  1. Endocardial tip cells in the human embryo - facts and hypotheses.

    Directory of Open Access Journals (Sweden)

    Mugurel C Rusu

    Full Text Available Experimental studies regarding coronary embryogenesis suggest that the endocardium is a source of endothelial cells for the myocardial networks. As this was not previously documented in human embryos, we aimed to study whether or not endothelial tip cells could be correlated with endocardial-dependent mechanisms of sprouting angiogenesis. Six human embryos (43-56 days were obtained and processed in accordance with ethical regulations; immunohistochemistry was performed for CD105 (endoglin, CD31, CD34, α-smooth muscle actin, desmin and vimentin antibodies. Primitive main vessels were found deriving from both the sinus venosus and aorta, and were sought to be the primordia of the venous and arterial ends of cardiac microcirculation. Subepicardial vessels were found branching into the outer ventricular myocardium, with a pattern of recruiting α-SMA+/desmin+ vascular smooth muscle cells and pericytes. Endothelial sprouts were guided by CD31+/CD34+/CD105+/vimentin+ endothelial tip cells. Within the inner myocardium, we found endothelial networks rooted from endocardium, guided by filopodia-projecting CD31+/CD34+/CD105+/ vimentin+ endocardial tip cells. The myocardial microcirculatory bed in the atria was mostly originated from endocardium, as well. Nevertheless, endocardial tip cells were also found in cardiac cushions, but they were not related to cushion endothelial networks. A general anatomical pattern of cardiac microvascular embryogenesis was thus hypothesized; the arterial and venous ends being linked, respectively, to the aorta and sinus venosus. Further elongation of the vessels may be related to the epicardium and subepicardial stroma and the intramyocardial network, depending on either endothelial and endocardial filopodia-guided tip cells in ventricles, or mostly on endocardium, in atria.

  2. Influence of metabolism modifiers of cyclic nucleotides on contractility of right ventricle of rat heart with intact and removed endocardial endothelium

    Directory of Open Access Journals (Sweden)

    Savić Slađana

    2010-01-01

    Full Text Available Introduction. Endocardial endothelium, a natural biological barrier between circulating blood in heart ventricle and cells, creates a complex yet finely tuned balance of interactions with the immediate environment. Objective. We investigated the roles of theophylline, nonspecific phosphodiesterase inhibitor, and imidazole, an activator of phosphodiesterase on contractility of the right ventricle of rat heart, with intact and removed endocardial endothelium. Methods. Adult rats, of both sexes, type Wistar albino, were used in this experiment. All experiments were conducted on the preparations of the right ventricle using two experimental models. In the first experimental model, an endocardial endothelium (EE was preserved, and in the second model, an endocardial endothelium (-EE was removed using 1% solution Triton X-100. Results. Theophylline (1x10-2 mol/l expressed the positive inotropic effect on the heart, regardless of the presence of the endocardial endothelium. Inotropic response as multiple process can be induced by inhibition of phosphodiesterase, accumulation of cyclic nucleotides and activation of Ca2+ channels. Imidazole (2x10-3 mol/l increased the contractility of the right ventricle of the heart with EE. The modulator effect of endocardial endothelium on contractility of imidazole proved to be significant. As imidazole influenced the contractility of the right ventricle only in the presence of the endocardial endothelium, it is assumed that its effect is mediated via deliverance of endothelial mediators with positive inotropic effect. Conclusion. An intact endocardial endothelium is necessary for completion of contractile performance of the heart.

  3. Acquired tricuspid valve stenosis associated with two ventricular endocardial pacing leads in a dog.

    Science.gov (United States)

    Tompkins, Emily; Dulake, Michelle I; Ghaffari, Shadie; Nakamura, Reid K

    2015-01-01

    Acquired tricuspid valve stenosis (TVS) is a rare complication of endocardial pacing lead implantation in humans that has only been described once previously in the veterinary literature in a dog with excessive lead redundancy. A 12 yr old terrier presented with right-sided congestive heart failure 6 mo after implantation of a second ventricular endocardial pacing lead. The second lead was placed due to malfunction of the first lead, which demonstrated abnormally low impedance. Transthoracic echocardiography identified hyperechoic tissue associated with the pacing leads as they crossed the tricuspid valve annulus as well as a stenotic tricuspid inflow pattern via spectral Doppler interrogation. Medical management was ultimately unsuccessful and the dog was euthanized 6 wk after TVS was diagnosed. The authors report the first canine case of acquired TVS associated with two ventricular endocardial pacing leads.

  4. Phrenic nerve injury: An underrecognized and potentially preventable complication of pulmonary vein isolation using a wide-area circumferential ablation approach.

    Science.gov (United States)

    Yong Ji, Sang; Dewire, Jane; Barcelon, Bernadette; Philips, Binu; Catanzaro, John; Nazarian, Saman; Cheng, Alan; Spragg, David; Tandri, Harikrishna; Bansal, Sandeep; Ashikaga, Hiroshi; Rickard, Jack; Kolandaivelu, Aravindan; Sinha, Sunil; Marine, Joseph E; Calkins, Hugh; Berger, Ronald

    2013-10-01

    Phrenic nerve injury (PNI) is a well-known, although uncommon, complication of pulmonary vein isolation (PVI) using radiofrequency energy. Currently, there is no consensus about how to avoid or minimize this injury. The purpose of this study was to determine how often the phrenic nerve, as identified using a high-output pacing, lies along the ablation trajectory of a wide-area circumferential lesion set. We also sought to determine if PVI can be achieved without phrenic nerve injury by modifying the ablation lesion set so as to avoid those areas where phrenic nerve capture (PNC) is observed. We prospectively enrolled 100 consecutive patients (age 61.7 ± 9.2 years old, 75 men) who underwent RF PVI using a wide-area circumferential ablation approach. A high-output (20 mA at 2 milliseconds) endocardial pacing protocol was performed around the right pulmonary veins and the carina where a usual ablation lesion set would be made. A total of 30% of patients had PNC and required modification of ablation lines. In the group of patients with PNC, the carina was the most common site of capture (85%) followed by anterior right superior pulmonary vein (RSPV) (70%) and anterior right inferior pulmonary vein (RIPV) (30%). A total of 25% of PNC group had capture in all 3 (RSPV, RIPV, and carina) regions. There was no difference in the clinical characteristics between the groups with and without PNC. RF PVI caused no PNI in either group. High output pacing around the right pulmonary veins and the carina reveals that the phrenic nerve lies along a wide-area circumferential ablation trajectory in 30% of patients. Modification of ablation lines to avoid these sites may prevent phrenic nerve injury during RF PVI. © 2013 Wiley Periodicals, Inc.

  5. Endocardial botulinum toxin injection into ganglionated plexi in order to reduce atrial fibrillation inducibility

    Directory of Open Access Journals (Sweden)

    А. Г. Стрельников

    2016-01-01

    Full Text Available Objective. Prior animal studies suggest that botulinum toxin injection into the epicardial fat pads can suppress atrial fibrillation (AF inducibility. The purpose of the present study was to assess the efficacy and safety of endocardial botulinum toxin injection into epicardial fat pads and intramyocardial left atrial ganglionated plexi (GP for preventing AF.Methods. Twenty-four dogs were separated into 3 groups: endocardial approach for botulinum toxin (Xeomin, Germany injection into epicardial fat pads and intramyocardial GPs; endocardial approach for placebo injection (0.9% normal saline; control 1; n = 8 and epicardial approach for botulinum toxin injection (control 2; n = 8.Results. A mean of 6.9±1.7 intramyocardial injections (10 U/0.2 mL at each and 3 injections (50 U/1 mL at each were administered into each site exhibiting a positive vagal response and into each epicardial fat pad in all groups (p>0.05 between groups.The injections of botulinum toxin demonstrated dramatic prolongation of ERP in all PV-atrial junctions. This effect correlated with less pronounced ERP shortening in response to vagal nerve stimulation. Suppression of AF inducibility was observed at 7 days after endocardial botulinum toxin injections. The level of AF inducibility was: at 7 days – 57% (p<0.001 vs placebo; p<0.001 vs baseline; at 14 days – 61% (p<0.001 vs placebo; p<0.001 vs baseline; at 1 month – 38% (p<0.001 vs placebo; p<0.001 vs baseline; at 3 months – 23% (p = 0.003; p = 0.06 vs baseline. There were no differences between botulinum groups (p>0.05 for all. The effect of AF suppression disappeared at 3 months. No procedure-related complications occurred.Conclusion. Botulinum toxin injection into intramyocardial GPs and epicardial fat pads by an endocardial approach is feasible and safe. It provides complete removal of cardiac vagal responses and reliably reduces vulnerability to atrial fibrillation.

  6. Unipolar Endocardial Voltage Mapping in the Right Ventricle: Optimal Cutoff Values Correcting for Computed Tomography-Derived Epicardial Fat Thickness and Their Clinical Value for Substrate Delineation.

    Science.gov (United States)

    Venlet, Jeroen; Piers, Sebastiaan R D; Kapel, Gijsbert F L; de Riva, Marta; Pauli, Philippe F G; van der Geest, Rob J; Zeppenfeld, Katja

    2017-08-01

    Low endocardial unipolar voltage (UV) at sites with normal bipolar voltage (BV) may indicate epicardial scar. Currently applied UV cutoff values are based on studies that lacked epicardial fat information. This study aimed to define endocardial UV cutoff values using computed tomography-derived fat information and to analyze their clinical value for right ventricular substrate delineation. Thirty-three patients (50±14 years; 79% men) underwent combined endocardial-epicardial right ventricular electroanatomical mapping and ablation of right ventricular scar-related ventricular tachycardia with computed tomographic image integration, including computed tomography-derived fat thickness. Of 6889 endocardial-epicardial mapping point pairs, 547 (8%) pairs with distance 1.50 mV, the optimal endocardial UV cutoff for identification of epicardial BV the curve, 0.75; sensitivity, 60%; specificity, 79%) and cutoff for identification of abnormal epicardial electrogram was 3.7 mV (area under the curve, 0.88; sensitivity, 100%; specificity, 67%). The majority of abnormal electrograms (130 of 151) were associated with transmural scar. Eighty-six percent of abnormal epicardial electrograms had corresponding endocardial sites with BV the remaining could be identified by corresponding low endocardial UV right ventricular scar, an endocardial UV cutoff value of 3.9 mV is more accurate than previously reported cutoff values. Although the majority of epicardial abnormal electrograms are associated with transmural scar with low endocardial BV, the additional use of endocardial UV at normal BV sites improves the diagnostic accuracy resulting in identification of all epicardial abnormal electrograms at sites with <1.0 mm fat. © 2017 American Heart Association, Inc.

  7. Systematic review and meta-analysis of left ventricular endocardial pacing in advanced heart failure: Clinically efficacious but at what cost?

    Science.gov (United States)

    Graham, Adam J; Providenica, Rui; Honarbakhsh, Shohreh; Srinivasan, Neil; Sawhney, Vinit; Hunter, Ross; Lambiase, Pier

    2018-04-01

    Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I 2  = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I 2  = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I 2  = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients. © 2018 Wiley Periodicals, Inc.

  8. Does circumferential tumor location affect the circumferential resection margin status in mid and low rectal cancer?

    Directory of Open Access Journals (Sweden)

    Byung Mo Kang

    2018-05-01

    Full Text Available Summary: Background/Objective: The purpose of this study was to assess the impact of circumferential tumor location on circumferential resection margin (CRM status and the depth of tumor invasion in mid and low rectal cancer. Methods: We retrospectively analyzed whole-mount slides of 58 patients who underwent total mesorectal excision for mid and low rectal cancer. The rate of tumor-positive CRM was compared according to the circumferential tumor location. In 31 patients, morphometric analyses of whole-mount specimens were performed to measure the depth of tumor invasion according to circumferential tumor location. Results: Among 58 patients, 50% of tumors were anterior tumor and 50% were nonanterior. A tumor-positive CRM was more observed frequently in anterior tumors than in nonanterior tumors (41.1% vs. 10.3%, p = 0.007. In a multivariate analysis, anterior tumor was the only independent risk factor for a positive CRM (odds ratio 4.725, 95% confidence interval 1.102–20.261, p = 0.037. In a morphometric analysis of 31 patients, the depth of tumor invasion from the muscularis mucosa was greater (11.9 mm vs. 6.6 mm, p = 0.028 in those with anterior tumors. Conclusion: Anterior tumors are associated with a higher risk of tumor-positive CRM and tend to exhibit deeper invasion in mid and low rectal cancer. Keywords: circumferential resection margin, depth of invasion, rectal cancer, tumor location

  9. Intracavitary ultrasound impairs left ventricular performance: presumed role of endocardial endothelium

    NARCIS (Netherlands)

    Gillebert, T. C.; de Hert, S. G.; Andries, L. J.; Jageneau, A. H.; Brutsaert, D. L.

    1992-01-01

    Irradiation of isolated cardiac muscle by high-power, high-frequency, continuous wave ultrasound selectively damages endocardial endothelium (EE). We evaluated this ultrasound effect in vivo on the performance of the intact ejecting canine left ventricle (LV). A cylindrical ultrasound probe (0.9

  10. Clinical and endorectal ultrasound staging of circumferential rectal cancers

    International Nuclear Information System (INIS)

    Smith, A.; Farmer, K.C.; Chapple, K.

    2008-01-01

    Full text: Circumferential rectal cancers present at a more advanced stage than those located in a single quadrant. Although accurate staging is an important aspect of the preoperative management of the patient with a rectal cancer, the clinical and radiological staging of this subgroup of rectal cancer patients has been poorly studied. All patients with a rectal cancer were assessed clinically (by digital rectal examination and rigid sigmoidoscopy) before the radiological assessment by endorectal ultrasound (ERUS). Data collected included tumour height (distance from anal verge in centimetre) and tumour type (circumferential or non-circumferential). Radiological tumour staging was with the TNM system. Fifty-nine subjects (33 men, 26 women; median age 65 years (range 38-86 years)) were identified with a circumferential rectal cancer. Mean height of the cancer was 8 - 0.4 cm (standard error of the mean; range 2-13 cm). Forty-two cancers were palpable, and 17 cancers were impalpable. All cancers assessed clinically as circumferential were confirmed as circumferential on ERUS scanning. Tumour stage as assessed by ERUS was either T3 (n = 57) or T4 (n = 2). Nodal status was NO (n = 29) and N1 (n = 30). All rectal cancers assessed as circumferential on clinical examination have an ERUS stage of T3 or greater.

  11. Circumferential shaft seal

    Science.gov (United States)

    Ludwig, L. P. (Inventor)

    1981-01-01

    A circumferential shaft seal comprising two sealing rings held to a rotating shaft by means of a surrounding elastomeric band is disclosed. The rings are segmented and are of a rigid sealing material such as carbon or a polyimide and graphite fiber composite.

  12. Ethical considerations of transparency, informed consent, and nudging in a patient with paediatric aortic stenosis and symptomatic left ventricular endocardial fibroelastosis.

    Science.gov (United States)

    Mavroudis, Constantine D; Cook, Thomas; Jacobs, Jeffrey P; Mavroudis, Constantine

    2016-12-01

    A 9-year-old boy who was born with bicuspid aortic stenosis underwent two unsuccessful aortic valvuloplasty interventions, and by 2 years of age he developed restrictive cardiomyopathy caused by left ventricular endocardial fibroelastosis and diastolic dysfunction. The attending cardiologist referred the patient to a high-volume, high-profile congenital cardiac surgical programme 1000 miles away that has a team with considerable experience with left ventricular endocardial fibroelastosis resection and a reputation of achieving good results. Owing to problems with insurance coverage, the parents sought other options for the care of their child in their home state. Dr George Miller is a well-respected local congenital and paediatric cardiac surgeon with considerable experience with the Ross operation as well as with right ventricular endocardial fibroelastosis resection. When talking with Dr Miller, he implied that there is little difference between right ventricular endocardial fibroelastosis and left ventricular endocardial fibroelastosis resection, and stated that he would perform the operation with low mortality based on his overall experience. Dr Miller stated that the local institution could provide an equivalent surgical procedure with comparable outcomes, without the patient and family having to travel out of state. A fundamental dilemma that often arises in clinical surgical practice concerns the conduct of assessing and performing new procedures, especially in rare cases, for which the collective global experience is scant. Although Dr Miller has performed right ventricular endocardial fibroelastosis resection, this procedure differs from left ventricular endocardial fibroelastosis resection, and he cannot be sure that he will indeed be able to perform the procedure better than the high-volume surgeon. This ethical situation is best understood in terms of the principles of respect for patient autonomy, beneficence, non-maleficence, and justice. The tension

  13. Prophylactic catheter ablation of ventricular tachycardia before cardioverter-defibrillator implantation in patients with non-ischemic cardiomyopathy: Clinical outcomes after a single endocardial ablation

    Directory of Open Access Journals (Sweden)

    Atsushi Suzuki, MD

    2015-06-01

    Conclusion: Single endocardial PCA can decrease ES occurrence in NICM patients. However, high rates of VT recurrence and low success rates are issues to be resolved; therefore, the efficacy of single endocardial PCA is currently limited.

  14. Endocardial fibrosarcoma in a reticulated python (Python reticularis).

    Science.gov (United States)

    Gumber, Sanjeev; Nevarez, Javier G; Cho, Doo-Youn

    2010-11-01

    A female, reticulated python (Python reticularis) of unknown age was presented with a history of lethargy, weakness, and distended coelom. Physical examination revealed severe dystocia and stomatitis. The reticulated python was euthanized due to a poor clinical prognosis. Postmortem examination revealed marked distention of the reproductive tract with 26 eggs (10-12 cm in diameter), pericardial effusion, and a slightly firm, pale tan mass (3-4 cm in diameter) adhered to the endocardium at the base of aorta. Based on histopathologic and transmission electron microscopic findings, the diagnosis of endocardial fibrosarcoma was made.

  15. Soft Tissue Reconstruction of Complete Circumferential Defects of the Upper Extremity

    Directory of Open Access Journals (Sweden)

    Zhi Yang Ng

    2017-03-01

    Full Text Available BackgroundUpper extremity soft tissue defects with complete circumferential involvement are not common. Coupled with the unique anatomy of the upper extremity, the underlying etiology of such circumferential soft tissue defects represent additional reconstructive challenges that require treatment to be tailored to both the patient and the wound. The aim of this study is to review the various options for soft tissue reconstruction of complete circumferential defects in the upper extremity.MethodsA literature review of PubMed and MEDLINE up to December 2016 was performed. The current study focuses on forearm and arm defects from the level at or proximal to the wrist and were assessed based on Tajima's classification (J Trauma 1974. Data reviewed for analysis included patient demographics, causality, defect size, reconstructive technique(s employed, and postoperative follow-up and functional outcomes (when available.ResultsIn accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, 14 unique articles were identified for a total of 50 patients (mean=28.1 years. Underlying etiologies varied from extensive thermal or electrical burns to high impact trauma leading to degloving or avulsion, crush injuries, or even occur iatrogenically after tumor extirpation or extensive debridement. Treatment options ranged from the application of negative pressure wound dressings to the opposite end of the spectrum in hand transplantation.ConclusionsWith the evolution of reconstructive techniques over time, the extent of functional and aesthetic rehabilitation of these complex upper extremity injuries has also improved. The proposed management algorithm comprehensively addresses the inherent challenges associated with these complex cases.

  16. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads.

    Science.gov (United States)

    Candinas, R; Duru, F; Schneider, J; Lüscher, T F; Stokes, K

    1999-02-01

    To analyze the site and thickness of encapsulation around ventricular endocardial pacing leads and the extent of tricuspid valve adhesion, from today's perspective, with implications for lead removal and sensor location. Gross cardiac postmortem analysis was performed in 11 cases (8 female and 3 male patients; mean age, 78+/-7 years). None of the patients had died because of pacemaker malfunction. The mean implant time was 61+/-60 months (range, 4 to 184). The observations ranged from encapsulation only at the tip of the pacing lead to complete encapsulation along the entire length of the pacing lead within the right ventricle. Substantial areas of adhesion at the tricuspid valve apparatus were noted in 7 of the 11 cases (64%). The firmly attached leads could be removed only by dissection, and in some cases, removal was possible only by damaging the associated structures. No specific optimal site for sensor placement could be identified along the ventricular portion of the pacing leads; however, the fibrotic response was relatively less prominent in the atrial chamber. Extensive encapsulation is present in most long-term pacemaker leads, which may complicate lead removal. The site and thickness of encapsulation seem to be highly variable. Tricuspid valve adhesion, which is usually underestimated, may be severe. In contrast to earlier reports, our study demonstrates that the extent of fibrotic encapsulation may not be related to the duration since lead implantation. Moreover, we noted no ideal encapsulation-free site for sensors on the ventricular portion of long-term pacing leads.

  17. Effects of endocardial microwave energy ablation

    Directory of Open Access Journals (Sweden)

    Vicente Climent

    2005-07-01

    Full Text Available Until recently the treatment of atrial fibrillation (AF consisted primarily of palliation, mostly in the form of pharmacological intervention. However because of recent advances in nonpharmacologic therapies, the current expectation of patients and referring physicians is that AF will be cured, rather than palliated. In recent years there has been a rapid expansion in the availability and variety of energy sources and devices for ablation. One of these energies, microwave, has been applied clinically only in the last few years, and may be a promising technique that is potentially capable of treating a wide range of ventricular and supraventricular arrhythmias. The purpose of this study was to review microwave energy ablation in surgical treatment of AF with special interest in histology and ultrastructure of lesions produced by this endocardial ablation procedure.

  18. Magnetic resonance imaging in complete type endocardial cushion defect

    International Nuclear Information System (INIS)

    Li Kuncheng; Yang Xiaoping; Yao Xinyu; Yang Yunxia; Liu Yuqing; Pang Zhixian

    1999-01-01

    Objective: To evaluate the value and limitation of magnetic resonance imaging (MRI) in complete type endocardial cushion defect (ETECD). Methods: Eight patients (male 5, female 3) were scanned by MRI with ECG-gated spin echo (SE) and gradient echo (GE) cine techniques. The diagnosis of CTECD was made by X-ray plain film, echocardiography, X-ray right cardiac catheterization and angiocardiography, as well as MRI four patients were treated with operation. Results: Every chamber of the heart was enlarged, more serious in the right atrium and ventricle, with thickening of right ventricular wall on MRI in majority of cases. The endocardial cushion disappeared, so the four chambers of the heart were directly connected with each other, and presented a cross shape. Ventricular septal membrane defect and type I atrial septal defect were depicted also. The normal structure of mitral and tricuspid valves were not intact. There were 6 cases with pulmonary hypertension, 2 cases with Tetralogy of Fallot, 4 cases with right aorta arch and descending aorta, 1 patient with dextroverted heart and another with persistent left superior vena cava connected with coronary sinus. The cine MRI could directly depict the situation of left-right or right-left shunt at atrial and ventricular levels, and regurgitation from ventricles to atria, meanwhile the valves were depicted clearly. Conclusions: MRI can clearly demonstrate all anatomic deformation and complicated hemodynamic change of CTECD, as well as other coexistent deformations

  19. Evaluating the roles of detailed endocardial structures on right ventricular haemodynamics by means of CFD simulations.

    Science.gov (United States)

    Sacco, Federica; Paun, Bruno; Lehmkuhl, Oriol; Iles, Tinen L; Iaizzo, Paul A; Houzeaux, Guillaume; Vázquez, Mariano; Butakoff, Constantine; Aguado-Sierra, Jazmin

    2018-06-11

    Computational modelling plays an important role in right ventricular (RV) haemodynamic analysis. However, current approaches employ smoothed ventricular anatomies. The aim of this study is to characterise RV haemodynamics including detailed endocardial structures like trabeculae, moderator band and papillary muscles (PMs). Four paired detailed and smoothed RV endocardium models (two male and two female) were reconstructed from ex-vivo human hearts high-resolution magnetic resonance images (MRI). Detailed models include structures with ≥1 mm 2 cross-sectional area. Haemodynamic characterisation was done by computational fluid dynamics (CFD) simulations with steady and transient inflows, using high performance computing (HPC). The differences between the flows in smoothed and detailed models were assessed using Q-criterion for vorticity quantification, the pressure drop between inlet and outlet, and the wall shear stress (WSS). Results demonstrated that detailed endocardial structures increase the degree of intra-ventricular pressure drop, decrease the WSS and disrupt the dominant vortex creating secondary small vortices. Increasingly turbulent blood flow was observed in the detailed RVs. Female RVs were less trabeculated and presented lower pressure drops than the males. In conclusion, neglecting endocardial structures in RV haemodynamic models may lead to inaccurate conclusions about the pressures, stresses, and blood flow behaviour in the cavity. This article is protected by copyright. All rights reserved.

  20. Layer-specific systolic and diastolic strain in  hypertensive patients with and without mild diastolic dysfunction

    Directory of Open Access Journals (Sweden)

    Hisham Sharif PhD

    2018-03-01

    Full Text Available This study sought to examine layer-specific longitudinal and circumferential systolic and diastolic strain, strain rate (SR and diastolic time intervals in hypertensive patients with and without diastolic dysfunction. Fifty-eight treated hypertensive patients were assigned to normal diastolic function (NDF, N = 39 or mild diastolic dysfunction (DD, N = 19 group. Layer-specific systolic and diastolic longitudinal and circumferential strains and SR were assessed. Results showed no between-group difference in left ventricular mass index (DD: 92.1 ± 18.1 vs NDF: 88.4 ± 16.3; P = 0.44. Patients with DD had a proportional reduction in longitudinal strain across the myocardium (endocardial for DD −13 ± 4%; vs NDF −17 ± 3, P < 0.01; epicardial for DD −10 ± 3% vs NDF −13 ± 3%, P < 0.01; global for DD: −12 ± 3% vs NDF: −15 ± 3, P = 0.01, and longitudinal mechanical diastolic impairments as evidenced by reduced longitudinal strain rate of early diastole (DD 0.7 ± 0.2 L/s vs NDF 1.0 ± 0.3 L/s, P < 0.01 and absence of a transmural gradient in the duration of diastolic strain (DD endocardial: 547 ± 105 ms vs epicardial: 542 ± 113 ms, P = 0.24; NDF endocardial: 566 ± 86 ms vs epicardial: 553 ± 77 ms, P = 0.03. Patients with DD also demonstrate a longer duration of early circumferential diastolic strain (231 ± 71 ms vs 189 ± 58 ms, P = 0.02. In conclusion, hypertensive patients with mild DD demonstrate a proportional reduction in longitudinal strain across the myocardium, as well as longitudinal mechanical diastolic impairment, and prolonging duration of circumferential mechanical relaxation.

  1. Circumferential wires as a supplement to intramedullary nailing in unstable trochanteric hip fractures

    DEFF Research Database (Denmark)

    Ban, Ilija; Birkelund, Lasse; Palm, Henrik

    2012-01-01

    Fixation of unstable trochanteric fractures is challenging. Application of a circumferential wire may facilitate bone contact and avoid postoperative fracture displacement. However, the use of circumferential wires remains controversial due to possible disturbance of the blood supply to the under......Fixation of unstable trochanteric fractures is challenging. Application of a circumferential wire may facilitate bone contact and avoid postoperative fracture displacement. However, the use of circumferential wires remains controversial due to possible disturbance of the blood supply...... to the underlying bone. We evaluated the results of applied circumferential wires, concentrating mainly on complications and reoperations....

  2. Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging

    NARCIS (Netherlands)

    Papavassiliu, T.; Kuhl, H.P.; Schroder, M.; Suselbeck, T.; Bondarenko, O.; Bohm, C.K.; van de Beek, A.; Hofman, M.M.; van Rossum, A.C.

    2005-01-01

    PURPOSE: To prospectively assess the effect of including or excluding endocardial trabeculae in left ventricular (LV) measurements and the reproducibility of these measurements at cine cardiovascular magnetic resonance (MR) imaging with true fast imaging with steady-state precession (FISP).

  3. Orthogonal electrode catheter array for mapping of endocardial focal site of ventricular activation

    Energy Technology Data Exchange (ETDEWEB)

    Desai, J.M.; Nyo, H.; Vera, Z.; Seibert, J.A.; Vogelsang, P.J. (Division of Cardiovascular Medicine, University of California, School of Medicine, Davis (USA))

    1991-04-01

    Precise location of the endocardial site of origin of ventricular tachycardia may facilitate surgical and catheter ablation of this arrhythmia. The endocardial catheter mapping technique can locate the site of ventricular tachycardia within 4-8 cm2 of the earliest site recorded by the catheter. This report describes an orthogonal electrode catheter array (OECA) for mapping and radiofrequency ablation (RFA) of endocardial focal site of origin of a plunge electrode paced model of ventricular activation in dogs. The OECA is an 8 F five pole catheter with four peripheral electrodes and one central electrode (total surface area 0.8 cm{sup 2}). In eight mongrel dogs, mapping was performed by arbitrarily dividing the left ventricle (LV) into four segments. Each segment was mapped with OECA to find the earliest segment. Bipolar and unipolar electrograms were obtained. The plunge electrode (not visible on fluoroscopy) site was identified by the earliest wave front arrival times of -30 msec or earlier at two or more electrodes (unipolar electrograms) with reference to the earliest recorded surface ECG (I, AVF, and V1). Validation of the proximity of the five electrodes of the OECA to the plunge electrode was performed by digital radiography and RFA. Pathological examination was performed to document the proximity of the OECA to the plunge electrode and also for the width, depth, and microscopic changes of the ablation. To find the segment with the earliest LV activation a total of 10 {plus minus} 3 (mean {plus minus} SD) positions were mapped. Mean arrival times at the two earlier electrodes were -39 {plus minus} 4 msec and -35 {plus minus} 3 msec. Digital radiography showed the plunge electrode to be within the area covered by all five electrodes in all eight dogs. The plunge electrode was within 1 cm2 area of the region of RFA in all eight dogs.

  4. Early development of the circumferential axonal pathway in mouse and chick spinal cord.

    Science.gov (United States)

    Holley, J A

    1982-03-10

    The early development of the circumferential axonal pathway in the brachial and lumbar spinal cord of mouse and chick embryos was studied by scanning and transmission electron microscopy. The cellular processes which comprise this pathway grow in the transverse plane and along the lateral margin of the marginal zone (i.e., circumferentially oriented), as typified by the early embryonic commissural axons. The first formative event observed was in the ventrolateral margin of the primitive spinal cord ventricular zone. Cellular processes were found near the external limiting membrane that appeared to grow a variable distance either dorsally or ventrally. Later in development, presumptive motor column neurons migrated into the ventrolateral region, distal to these early circumferentially oriented processes. Concurrently, other circumferentially oriented perikarya and processes appeared along the dorsolateral margin. Due to their aligned sites of origin and parallel growth, the circumferential processes formed a more or less continuous line or pathway, which in about 10% of the scanned specimens could be followed along the entire lateral margin of the embryonic spinal cord. Several specimens later in development had two sets of aligned circumferential processes in the ventral region. Large numbers of circumferential axons were then found to follow the preformed pathway by fasciculation, after the primitive motor column had become established. Since the earliest circumferential processes appeared to differentiate into axons and were found nearly 24 hours prior to growth of most circumferential axons, their role in guidance as pioneering axons was suggested.

  5. Experimental circumferential canaloplasty with a new Schlemm canal microcatheter

    Directory of Open Access Journals (Sweden)

    Mao-Song Xie

    2018-01-01

    Full Text Available AIM: To present a new, simple, inexpensive Schlemm canal microcatheter for circumferential canaloplasty in a rabbit model. METHODS: A rabbit glaucoma animal model was established by intravitreal injection of triamcinolone acetonide. Circumferential canaloplasty with a new Schlemm canal microcatheter (patent license number: 201220029850.0 was performed. The Schlemm canal microcatheter was composed of microcatheter wall and lumen. The wall was made of high refractive index plastic optical fiber that could be attached to an illuminant so that the whole lighted microcatheter was visible during circumferential canaloplasty. The lumen could be attached to an injector for injection of viscoelastic during catheterization. Rabbits were divided randomly into the control, model and treatment groups. Intraocular pressure (IOP was measured with a Tono-pen tonometer pre-operation and 3, 7, 14, 21 and 28d post-operation. Ultrasound biomicroscopy was performed to visualize the Schlemm canal microcatheter in the Schlemm canal and the sclera pool. RESULTS: The Schlemm canal microcatheter could be used to perform circumferential canaloplasty in the rabbit glaucoma animal model. IOP was lower in the treatment group than that in the model group 3, 7, 14 and 28d after operation. There were no significant differences in IOP between the control group and treatment group. The differences among the three groups were statistically significant (3d: F=41.985, P<0.001; 7d: F=65.696, P<0.001; 14d: F=114.599, P<0.001; 28d: F=55.006, P<0.001. CONCLUSION: Circumferential canaloplasty is safe and effective in control of experimental glaucoma model in rabbits.

  6. Circumferential cracking of steam generator tubes

    International Nuclear Information System (INIS)

    Karwoski, K.J.

    1997-04-01

    On April 28, 1995, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 95-03, open-quote Circumferential Cracking of Steam Generator Tubes.close-quote GL 95-03 was issued to obtain information needed to verify licensee compliance with existing regulatory requirements regarding the integrity of steam generator tubes in domestic pressurized-water reactors (PWRs). This report briefly describes the design and function of domestic steam generators and summarizes the staff's assessment of the responses to GL 95-03. The report concludes with several observations related to steam generator operating experience. This report is intended to be representative of significant operating experience pertaining to circumferential cracking of steam generator tubes from April 1995 through December 1996. Operating experience prior to April 1995 is discussed throughout the report, as necessary, for completeness

  7. Circumferential fusion improves outcome in comparison with instrumented posterolateral fusion

    DEFF Research Database (Denmark)

    Videbaek, Tina S; Christensen, Finn B; Soegaard, Rikke

    2006-01-01

    with respect to all four DPQ categories: daily activities, work/leisure, anxiety/depression, and social interest. The Oswestry Disability Index supported these results (P ...STUDY DESIGN: Prospective randomized clinical study with a 5- to 9-year follow-up period. OBJECTIVE: The aim of the present study was to analyze the long-term outcome with respect to functional disability, pain, and general health of patients treated by means of circumferential lumbar fusion...... in comparison with those treated by means of instrumented posterolateral lumbar fusion. SUMMARY OF BACKGROUND DATA: Circumferential fusion has become a common procedure in lumbar spinal fusion both as a primary and salvage procedure. However, the claimed advantages of circumferential fusion over conventional...

  8. Overlapping and differential localization of Bmp-2, Bmp-4, Msx-2 and apoptosis in the endocardial cushion and adjacent tissues of the developing mouse heart.

    Science.gov (United States)

    Abdelwahid, E; Rice, D; Pelliniemi, L J; Jokinen, E

    2001-07-01

    The bone morphogenetic proteins BMP-2 and BMP-4 and the homeobox gene MSX-2 are required for normal development of many embryonic tissues. To elucidate their possible roles during the remodeling of the tubular heart into a fully septated four-chambered heart, we have localized the mRNA of Bmp-2, Bmp-4, Msx-2 and apoptotic cells in the developing mouse heart from embryonic day (E)11 to E17. mRNA was localized by in situ hybridization, and apoptotic cells by TUNEL (TDT-mediated dUTP-biotin nick end-labeling) as well as by transmission electron microscopy. By analyzing adjacent serial sections, we demonstrated that the expression of Msx-2 and Bmp-2 strikingly overlapped in the atrioventricular canal myocardium, in the atrioventricular junctional myocardium, and in the maturing myocardium of the atrioventricular valves. Bmp-4 was expressed in the outflow tract myocardium and in the endocardial cushion of the outflow tract ridges from E12 to E14. Msx-2 appeared in the mesenchyme of the atrioventricular endocardial cushion from E11 to E14, while Bmp-2 and Bmp-4 were detected between E11 and E14. Apoptotic cells were also detected in the mesenchyme of the endocardial cushion between E12 and E14. Our results suggest that BMP-2 and MSX-2 are tightly linked to the formation of the atrioventricular junction and valves and that BMP-4 is involved in the development of the outflow tract myocardium and of the endocardial cushion. In addition, BMP-2, BMP-4 and MSX-2 and apoptosis seem to be associated with differentiation of the endocardial cushion.

  9. Experimental Observation of Cumulative Second-Harmonic Generation of Circumferential Guided Wave Propagation in a Circular Tube

    International Nuclear Information System (INIS)

    Deng Ming-Xi; Gao Guang-Jian; Li Ming-Liang

    2015-01-01

    The experimental observation of cumulative second-harmonic generation of the primary circumferential guided wave propagation is reported. A pair of wedge transducers is used to generate the primary circumferential guided wave desired and to detect its fundamental-frequency and second-harmonic amplitudes on the outside surface of the circular tube. The amplitudes of the fundamental waves and the second harmonics of the circumferential guided wave propagation are measured for different separations between the two wedge transducers. At the driving frequency where the primary and the double-frequency circumferential guided waves have the same linear phase velocities, the clear second-harmonic signals can be observed. The quantitative relationships between the second-harmonic amplitudes and circumferential angle are analyzed. It is experimentally verified that the second harmonics of primary circumferential guided waves do have a cumulative growth effect with the circumferential angle. (paper)

  10. Characteristics and identification of sites of chagasic ventricular tachycardia by endocardial mapping

    Directory of Open Access Journals (Sweden)

    Távora Maria Zildany P.

    1999-01-01

    Full Text Available OBJECTIVE: To study electrophysiological characteristics that enable the identification and ablation of sites of chagasic tachycardia. METHODS: Thirty-one patients with chronic Chagas' heart disease and sustained ventricular tachycardia (SVT underwent electrophysiological study to map and ablate that arrhythmia. Fifteen patients had hemodinamically stable SVT reproducible by programmed ventricular stimulation, 9 men and 6 women with ages ranging from 37 to 67 years and ejection fraction varying from 0.17 to 0.64. Endocardial mapping was performed during SVT in all patients. Radiofrequency (RF current was applied to sites of presystolic activity of at least 30 ms. Entrainment was used to identify reentrant circuits. In both successful and unsuccessful sites of RF current application, electrogram and entrainment were analyzed. RESULTS: Entrainment was obtained during all mapped SVT. In 70.5% of the sites we observed concealed entrainment and ventricular tachycardia termination in the first 15 seconds of RF current application. In the unsuccessful sites, significantly earlier electrical activity was seen than in the successful ones. Concealed entrainment was significantly associated with ventricular tachycardia termination. Bystander areas were not observed. CONCLUSION: The reentrant mechanism was responsible for the genesis of all tachycardias. In 70.5% of the studied sites, the endocardial participation of the slow conducting zone of reentrant circuits was shown. Concealed entrainment was the main electrophysiological parameter associated with successful RF current application. There was no electrophysiological evidence of bystander regions in the mapped circuits of SVT.

  11. Guided Circumferential Waves in Layered Poroelastic Cylinders

    Directory of Open Access Journals (Sweden)

    Shah S.A.

    2016-12-01

    Full Text Available The present paper investigates the propagation of time harmonic circumferential waves in a two-dimensional hollow poroelastic cylinder with an inner shaft (shaft-bearing assembly. The hollow poroelastic cylinder and inner shaft are assumed to be infinite in axial direction. The outer surface of the cylinder is stress free and at the interface, between the inner shaft and the outer cylinder, it is assumed to be free sliding and the interfacial shear stresses are zero, also the normal stress and radial displacements are continuous. The frequency equation of guided circumferential waves for a permeable and an impermeable surface is obtained. When the angular wave number vanish the frequency equation of guided circumferential waves for a permeable and an impermeable surface degenerates and the dilatational and shear waves are uncoupled. Shear waves are independent of the nature of surface. The frequency equation of a permeable and an impermeable surface for bore-piston assembly is obtained as a particular case of the model under consideration when the outer radius of the hollow poroelastic cylinder tends to infinity. Results of previous studies are obtained as a particular case of the present study. Nondimensional frequency as a function of wave number is presented graphically for two types of models and discussed. Numerical results show that, in general, the first modes are linear for permeable and impermeable surfaces and the frequency of a permeable surface is more than that of an impermeable surface.

  12. Quantification of biventricular myocardial function using cardiac magnetic resonance feature tracking, endocardial border delineation and echocardiographic speckle tracking in patients with repaired tetralogy of fallot and healthy controls

    Science.gov (United States)

    2012-01-01

    Background Parameters of myocardial deformation have been suggested to be superior to conventional measures of ventricular function in patients with tetralogy of Fallot (ToF), but have required non-routine, tagged cardiovascular magnetic resonance (CMR) techniques. We assessed biventricular myocardial function using CMR cine-based feature tracking (FT) and compared it to speckle tracking echocardiography (STE) and to simple endocardial border delineation (EBD). In addition, the relation between parameters of myocardial deformation and clinical parameters was assessed. Methods Overall, 28 consecutive adult patients with repaired ToF (age 40.4 ± 13.3 years) underwent standard steady-state-free precession sequence CMR, echocardiography, and cardiopulmonary exercise testing. In addition, 25 healthy subjects served as controls. Myocardial deformation was assessed by CMR based FT (TomTec Diogenes software), CMR based EBD (using custom written software) and STE (TomTec Cardiac Performance Analysis software). Results Feature tracking was feasible in all subjects. A close agreement was found between measures of global left (LV) and right ventricular (RV) global strain. Interobserver agreement for FT and STE was similar for longitudinal LV global strain, but FT showed better inter-observer reproducibility than STE for circumferential or radial LV and longitudinal RV global strain. Reproducibility of regional strain on FT was, however, poor. The relative systolic length change of the endocardial border measured by EBD yielded similar results to FT global strain. Clinically, biventricular longitudinal strain on FT was reduced compared to controls (P < 0.0001) and was related to the number of previous cardiac operations. In addition, FT derived RV strain was related to exercise capacity and VE/VCO2-slope. Conclusions Although neither the inter-study reproducibility nor accuracy of FT software were investigated, and its inter-observer reproducibility for regional

  13. Usefulness of ventricular endocardial electric reconstruction from body surface potential maps to noninvasively localize ventricular ectopic activity in patients

    Science.gov (United States)

    Lai, Dakun; Sun, Jian; Li, Yigang; He, Bin

    2013-06-01

    As radio frequency (RF) catheter ablation becomes increasingly prevalent in the management of ventricular arrhythmia in patients, an accurate and rapid determination of the arrhythmogenic site is of important clinical interest. The aim of this study was to test the hypothesis that the inversely reconstructed ventricular endocardial current density distribution from body surface potential maps (BSPMs) can localize the regions critical for maintenance of a ventricular ectopic activity. Patients with isolated and monomorphic premature ventricular contractions (PVCs) were investigated by noninvasive BSPMs and subsequent invasive catheter mapping and ablation. Equivalent current density (CD) reconstruction (CDR) during symptomatic PVCs was obtained on the endocardial ventricular surface in six patients (four men, two women, years 23-77), and the origin of the spontaneous ectopic activity was localized at the location of the maximum CD value. Compared with the last (successful) ablation site (LAS), the mean and standard deviation of localization error of the CDR approach were 13.8 and 1.3 mm, respectively. In comparison, the distance between the LASs and the estimated locations of an equivalent single moving dipole in the heart was 25.5 ± 5.5 mm. The obtained CD distribution of activated sources extending from the catheter ablation site also showed a high consistency with the invasively recorded electroanatomical maps. The noninvasively reconstructed endocardial CD distribution is suitable to predict a region of interest containing or close to arrhythmia source, which may have the potential to guide RF catheter ablation.

  14. Endocardial left ventricle feature tracking and reconstruction from tri-plane trans-esophageal echocardiography data

    Science.gov (United States)

    Dangi, Shusil; Ben-Zikri, Yehuda K.; Cahill, Nathan; Schwarz, Karl Q.; Linte, Cristian A.

    2015-03-01

    Two-dimensional (2D) ultrasound (US) has been the clinical standard for over two decades for monitoring and assessing cardiac function and providing support via intra-operative visualization and guidance for minimally invasive cardiac interventions. Developments in three-dimensional (3D) image acquisition and transducer design and technology have revolutionized echocardiography imaging enabling both real-time 3D trans-esophageal and intra-cardiac image acquisition. However, in most cases the clinicians do not access the entire 3D image volume when analyzing the data, rather they focus on several key views that render the cardiac anatomy of interest during the US imaging exam. This approach enables image acquisition at a much higher spatial and temporal resolution. Two such common approaches are the bi-plane and tri-plane data acquisition protocols; as their name states, the former comprises two orthogonal image views, while the latter depicts the cardiac anatomy based on three co-axially intersecting views spaced at 600 to one another. Since cardiac anatomy is continuously changing, the intra-operative anatomy depicted using real-time US imaging also needs to be updated by tracking the key features of interest and endocardial left ventricle (LV) boundaries. Therefore, rapid automatic feature tracking in US images is critical for three reasons: 1) to perform cardiac function assessment; 2) to identify location of surgical targets for accurate tool to target navigation and on-target instrument positioning; and 3) to enable pre- to intra-op image registration as a means to fuse pre-op CT or MR images used during planning with intra-operative images for enhanced guidance. In this paper we utilize monogenic filtering, graph-cut based segmentation and robust spline smoothing in a combined work flow to process the acquired tri-plane TEE time series US images and demonstrate robust and accurate tracking of the LV endocardial features. We reconstruct the endocardial LV

  15. Status of the steam generator tube circumferential ODSCC degradation experienced at the Doel 4 plant

    International Nuclear Information System (INIS)

    Roussel, G.

    1997-01-01

    Since the 1991 outage, the Doel Unit 4 nuclear power plant is known to be affected by circumferential outside diameter intergranular stress corrosion cracking at the hot leg tube expansion transition. Extensive non destructive examination inspections have shown the number of tubes affected by this problem as well as the size of the cracks to have been increasing for the three cycles up to 1993. As a result of the high percentage of tubes found non acceptable for continued service after the 1993 in-service inspection, about 1,700 mechanical sleeves were installed in the steam generators. During the 1994 outage, all the tubes sleeved during the 1993 outage were considered as potentially cracked to some extent at the upper hydraulic transition and were therefore not acceptable for continued service. They were subsequently repaired by laser welding. Furthermore all the tubes not sleeved during the 1993 outage were considered as not acceptable for continued service and were repaired by installing laser welded sleeves. During the 1995 outage, some unexpected degradation phenomena were evidenced in the sleeved tubes. This paper summarizes the status of the circumferential ODSCC experienced in the SG tubes of the Doel 4 plant as well as the other connected degradation phenomena

  16. Alteration of left ventricular endocardial function by intracavitary high-power ultrasound interacts with volume, inotropic state, and alpha 1-adrenergic stimulation

    NARCIS (Netherlands)

    de Hert, S. G.; Gillebert, T. C.; Brutsaert, D. L.

    1993-01-01

    BACKGROUND: High-power intracavitary ultrasound abbreviates left ventricular (LV) ejection duration, thereby decreasing mechanical LV performance, presumably by selective impairment of endocardial endothelial function. METHODS AND RESULTS: Effects of ultrasound were evaluated in the ejecting LV of

  17. Circumferential buckling instability of a growing cylindrical tube

    KAUST Repository

    Moulton, D.E.; Goriely, A.

    2011-01-01

    A cylindrical elastic tube under uniform radial external pressure will buckle circumferentially to a non-circular cross-section at a critical pressure. The buckling represents an instability of the inner or outer edge of the tube. This is a common

  18. Nickel-titanium wire in circumferential suture of a flexor tendon repair: a comparison to polypropylene.

    Science.gov (United States)

    Karjalainen, T; He, M; Chong, A K S; Lim, A Y T; Ryhanen, J

    2010-07-01

    Nickel-titanium (NiTi) has been proposed as an alternative material for flexor tendon core suture. To our knowledge, its suitability as a circumferential suture of flexor tendon repair has not been investigated before. The purpose of this ex vivo study was to investigate the biomechanical properties of NiTi circumferential repairs and to compare them with commonly used polypropylene. Forty porcine flexor tendons were cut and repaired by simple running or interlocking mattress technique using 100 microm NiTi wire or 6-0 polypropylene. The NiTi circumferential repairs showed superior stiffness, gap resistance, and load to failure when compared to polypropylene repairs with both techniques. Nickel-titanium wire seems to be a potential material for circumferential repair of flexor tendons. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. Consideration on evaluation of internal pressure creep rupture for tube with circumferential joint

    International Nuclear Information System (INIS)

    Nagato, Kotaro; Satoh, Keisuke

    1983-01-01

    The behavior of internal pressure creep rupture of the thin-walled cylinders with circumferential joints is affected by the combination of creep characteristics of parent materials and weld metals. In particular, the compatibility of the creep strain rate of parent materials and weld metals becomes an important controlling factor. The behavior of internal pressure creep of the welded parts in circumferential joint cylinders can be evaluated simply with the uniaxial creep data of parent materials and weld metals, considering it by approximately substituting with the creep behavior of a uniaxial longitudinal joint. The method of evaluation is, first, to analyze the breaking behavior of uniaxial longitudinal joints using the uniaxial creep characteristic values of parent materials and weld metals, and next, by combining the equation for the relation between the rupture times of uniaxial creep and internal pressure creep with the analyzed breaking behavior of uniaxial joints, the internal pressure creep rupture behavior of the cylinders with circumferential joints can be evaluated. The internal pressure creep behavior of the thin-walled cylinders with circumferential joints, their rupture life and the uniaxial creep rupture life of longitudinal joints, and the examination of Hastelloy X cylinders are reported. (Kako, I.)

  20. Optimization of the axial compressor flow passage to reduce the circumferential distortion

    Science.gov (United States)

    Popov, G.; Kolmakova, D.; Shklovets, A.; Ermakov, A.

    2015-08-01

    This work is motivated by the necessity to reduce the effects of the flow circumferential distortion in the flow passage of the aircraft gas turbine engine (GTE). In previous research, the authors have proposed the approaches to decrease of the flow circumferential distortion arising from the mid-support racks of GTE compressor and having a negative impact on the blade rows, located upstream. In particular, the idea of introducing the circumferentially non-uniform blade pitch and profile stagger angle of guide vanes located in front of the support was contributed in order to redistribute the flow and decrease the dynamic stresses in the rotor wheel of the same stage. During the research presented in this paper, another principal of reduction of the flow circumferential distortion was chosen. Firstly, the variants of upgrading the existing support racks were found. Secondly, the new design of support was offered. Both the first and the second version of the support design variation took into account the availability of technological and structural limitations associated with the location of oil pipes, springs and others elements in the support racks. Investigations of modified design showed that the support with altered racks provides a reduction of dynamic stresses by 20% at resonance with the most dangerous harmonic, and the new design of support can give the decrease of 30%.

  1. Circumferential buckling instability of a growing cylindrical tube

    KAUST Repository

    Moulton, D.E.

    2011-03-01

    A cylindrical elastic tube under uniform radial external pressure will buckle circumferentially to a non-circular cross-section at a critical pressure. The buckling represents an instability of the inner or outer edge of the tube. This is a common phenomenon in biological tissues, where it is referred to as mucosal folding. Here, we investigate this buckling instability in a growing elastic tube. A change in thickness due to growth can have a dramatic impact on circumferential buckling, both in the critical pressure and the buckling pattern. We consider both single- and bi-layer tubes and multiple boundary conditions. We highlight the competition between geometric effects, i.e. the change in tube dimensions, and mechanical effects, i.e. the effect of residual stress, due to differential growth. This competition can lead to non-intuitive results, such as a tube growing to be thinner and yet buckle at a higher pressure. © 2011 Elsevier Ltd. All rights reserved.

  2. Clinical implication of negative conversion of predicted circumferential resection margin status after preoperative chemoradiotherapy for locally advanced rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Kwon [Department of Radiation Oncology, Korea University Medical Center, Korea University College of Medicine, Seoul (Korea, Republic of); Kim, Chul Yong, E-mail: kcyro@korea.ac.kr [Department of Radiation Oncology, Korea University Medical Center, Korea University College of Medicine, Seoul (Korea, Republic of); Park, Young Je; Yang, Dae Sik; Yoon, Won Sup [Department of Radiation Oncology, Korea University Medical Center, Korea University College of Medicine, Seoul (Korea, Republic of); Kim, Seon Hahn; Kim, Jin [Division of Colorectal Surgery, Department of Surgery, Korea University Medical Center, Korea University College of Medicine, Seoul (Korea, Republic of)

    2014-02-15

    Objective: To evaluate the prognostic implication of the negative conversion of predicted circumferential resection margin status before surgery in patients with locally advanced rectal cancer with predicted circumferential resection margin involvement. Methods: Thirty-eight patients (28 men, 10 women; median age, 61 years; age range, 39–80 years) with locally advanced rectal cancer with predicted circumferential resection margin involvement who underwent preoperative chemoradiotherapy followed by radical surgery were analyzed. Involvement of the circumferential resection margin was predicted on the basis of pre- and post-chemoradiotherapy magnetic resonance imaging. The primary endpoints were 3-year local recurrence-free survival and overall survival. Results: The median follow-up time was 41.1 months (range, 13.9–85.2 months). The negative conversion rate of predicted circumferential resection margin status after preoperative chemoradiotherapy was 65.8%. Patients who experienced negative conversion of predicted circumferential resection margin status had a significantly higher 3-year local recurrence-free survival rate (100.0% vs. 76.9%; P = 0.013), disease-free survival rate (91.7% vs. 59.3%; P = 0.023), and overall survival rate (96.0% vs. 73.8%; P = 0.016) than those who had persistent circumferential resection margin involvement. Conclusions: The negative conversion of the predicted circumferential resection margin status as predicted by magnetic resonance imaging will assist in individual risk stratification as a predictive factor for treatment response and survival before surgery. These findings may help physicians determine whether to administer more intense adjuvant chemotherapy or change the surgical plan for patients displaying resistance to preoperative chemoradiotherapy.

  3. Risk Factors Associated With Circumferential Resection Margin Positivity in Rectal Cancer: A Binational Registry Study.

    Science.gov (United States)

    Warrier, Satish K; Kong, Joseph Cherng; Guerra, Glen R; Chittleborough, Timothy J; Naik, Arun; Ramsay, Robert G; Lynch, A Craig; Heriot, Alexander G

    2018-04-01

    Rectal cancer outcomes have improved with the adoption of a multidisciplinary model of care. However, there is a spectrum of quality when viewed from a national perspective, as highlighted by the Consortium for Optimizing the Treatment of Rectal Cancer data on rectal cancer care in the United States. The aim of this study was to assess and identify predictors of circumferential resection margin involvement for rectal cancer across Australasia. A retrospective study from a prospectively maintained binational colorectal cancer database was interrogated. This study is based on a binational colorectal cancer audit database. Clinical information on all consecutive resected rectal cancer cases recorded in the registry from 2007 to 2016 was retrieved, collated, and analyzed. The primary outcome measure was positive circumferential resection margin, measured as a resection margin ≤1 mm. A total of 3367 patients were included, with 261 (7.5%) having a positive circumferential resection margin. After adjusting for hospital and surgeon volume, hierarchical logistic regression analysis identified a 6-variable model encompassing the independent predictors, including urgent operation, abdominoperineal resection, open technique, low rectal cancer, T3 to T4, and N1 to N2. The accuracy of the model was 92.3%, with an receiver operating characteristic of 0.783 (p risk associated with circumferential resection margin positivity ranged from risk factors) to 43% (6 risk factors). This study was limited by the lack of recorded long-term outcomes associated with circumferential resection margin positivity. The rate of circumferential resection margin involvement in patients undergoing rectal cancer resection in Australasia is low and is influenced by a number of factors. Risk stratification of outcome is important with the increasing demand for publicly accessible quality data. See Video Abstract at http://links.lww.com/DCR/A512.

  4. Nonlinear Analysis of Two-phase Circumferential Motion in the Ablation Circumstance

    Science.gov (United States)

    Xiao-liang, Xu; Hai-ming, Huang; Zi-mao, Zhang

    2010-05-01

    In aerospace craft reentry and solid rocket propellant nozzle, thermal chemistry ablation is a complex process coupling with convection, heat transfer, mass transfer and chemical reaction. Based on discrete vortex method (DVM), thermal chemical ablation model and particle kinetic model, a computational module dealing with the two-phase circumferential motion in ablation circumstance is designed, the ablation velocity and circumferential field can be thus calculated. The calculated nonlinear time series are analyzed in chaotic identification method: relative chaotic characters such as correlation dimension and the maximum Lyapunov exponent are calculated, fractal dimension of vortex bulbs and particles distributions are also obtained, thus the nonlinear ablation process can be judged as a spatiotemporal chaotic process.

  5. The prediction of the-circumferential fuel-temperature distribution under ballonian condition. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    Abdallah, A M; El-Sherbiny, E M [Reactor Department, Nuclear Research Center, Atomic Energy Authority, Cairo (Egypt)

    1996-03-01

    Swelling and thermal distortion of nuclear fuel elements due to depressurization of reactor coolant may cause contracts in points or finite regions between adjacent fuel elements in square and triangle lattices. This is very probable in Advanced Pressurized Water Reactors where the clearance between fuel elements is about 1 mm. This results in partial blocking of the coolant flow and formation of hot spots in the contact regions. In these regions, absence of coolant results in nonuniform clad circumferential temperature distribution. This causes excessive thermal stresses which may produce local melting or clad failure. An accurate prediction of the clad circumferential temperature distribution during these severe incidents is very important. This problem was studied numerically during transient and steady state conditions. Recently, a semi analytical solution for the underlying problem was derived assuming the heat transfer coefficient to vary linearly with the circumferential distance measured from the cusp point, and the heat flux at the fuel-clad interface to be a constant quantity. In the present work, an approximate analytic solution is obtained. The accuracy is tested by solving the problem numerically. Also the problem is reanalyzed by considering the heat flux at the fuel-clad interface to be a power function of the angular distance along the clad surface. Moreover, the heat transfer coefficient is assumed to be a function of both the circumferential coordinate and temperature of the clad. Discussion of the analytical solution and the assumptions are rationalized in the text. 4 figs.

  6. MEMS-based non-rotatory circumferential scanning optical probe for endoscopic optical coherence tomography

    Science.gov (United States)

    Xu, Yingshun; Singh, Janak; Siang, Teo Hui; Ramakrishna, Kotlanka; Premchandran, C. S.; Sheng, Chen Wei; Kuan, Chuah Tong; Chen, Nanguang; Olivo, Malini C.; Sheppard, Colin J. R.

    2007-07-01

    In this paper, we present a non-rotatory circumferential scanning optical probe integrated with a MEMS scanner for in vivo endoscopic optical coherence tomography (OCT). OCT is an emerging optical imaging technique that allows high resolution cross-sectional imaging of tissue microstructure. To extend its usage to endoscopic applications, a miniaturized optical probe based on Microelectromechanical Systems (MEMS) fabrication techniques is currently desired. A 3D electrothermally actuated micromirror realized using micromachining single crystal silicon (SCS) process highlights its very large angular deflection, about 45 degree, with low driving voltage for safety consideration. The micromirror is integrated with a GRIN lens into a waterproof package which is compatible with requirements for minimally invasive endoscopic procedures. To implement circumferential scanning substantially for diagnosis on certain pathological conditions, such as Barret's esophagus, the micromirror is mounted on 90 degree to optical axis of GRIN lens. 4 Bimorph actuators that are connected to the mirror on one end via supporting beams and springs are selected in this micromirror design. When actuators of the micromirror are driven by 4 channels of sinusoidal waveforms with 90 degree phase differences, beam focused by a GRIN is redirected out of the endoscope by 45 degree tilting mirror plate and achieve circumferential scanning pattern. This novel driving method making full use of very large angular deflection capability of our micromirror is totally different from previously developed or developing micromotor-like rotatory MEMS device for circumferential scanning.

  7. Modification of the ASME code z-factor for circumferential surface crack in nuclear ferritic pipings

    International Nuclear Information System (INIS)

    Choi, Young Hwan; Chung, Yon Ki; Koh, Wan Young; Lee, Joung Bae

    1996-01-01

    The purpose of this paper is to modify the ASME Code Z-Factor, which is used in the evaluation of circumferential surface crack in nuclear ferritic pipings. The ASME Code Z-Factor is a load multiplier to compensate plastic load with elasto-plastic load. The current ASME Code Z-Factor underestimates pipe maximum load. In this study, the original SC. TNP method is modified first because the original SC. TNP method has a problem that the maximum allowable load predicted from the original SC. TNP method is slightly higher than that measured from the experiment. Then the new Z-Factor is developed using the modified SC. TNP method. The desirability of both the modified SC. TNP method and the new Z-Factor is examined using the experimental results for the circumferential surface crack in pipings. The results show that (1) the modified SC. TNP method is good for predicting the circumferential surface crack behavior in pipings, and (2) the Z-Factor obtained from the modified SC. TNP method well predicts the behavior of circumferential surface crack in ferritic pipings. 30 refs., 13 figs., 4 tabs. (author)

  8. Circumferential optical coherence tomography angiography imaging of the swine esophagus using a micromotor balloon catheter.

    Science.gov (United States)

    Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Liang, Kaicheng; Wang, Zhao; Cleveland, Cody; Booth, Lucas; Potsaid, Benjamin; Jayaraman, Vijaysekhar; Cable, Alex E; Mashimo, Hiroshi; Langer, Robert; Traverso, Giovanni; Fujimoto, James G

    2016-08-01

    We demonstrate a micromotor balloon imaging catheter for ultrahigh speed endoscopic optical coherence tomography (OCT) which provides wide area, circumferential structural and angiographic imaging of the esophagus without contrast agents. Using a 1310 nm MEMS tunable wavelength swept VCSEL light source, the system has a 1.2 MHz A-scan rate and ~8.5 µm axial resolution in tissue. The micromotor balloon catheter enables circumferential imaging of the esophagus at 240 frames per second (fps) with a ~30 µm (FWHM) spot size. Volumetric imaging is achieved by proximal pullback of the micromotor assembly within the balloon at 1.5 mm/sec. Volumetric data consisting of 4200 circumferential images of 5,000 A-scans each over a 2.6 cm length, covering a ~13 cm(2) area is acquired in <18 seconds. A non-rigid image registration algorithm is used to suppress motion artifacts from non-uniform rotational distortion (NURD), cardiac motion or respiration. En face OCT images at various depths can be generated. OCT angiography (OCTA) is computed using intensity decorrelation between sequential pairs of circumferential scans and enables three-dimensional visualization of vasculature. Wide area volumetric OCT and OCTA imaging of the swine esophagus in vivo is demonstrated.

  9. Positioning means for circumferentially locating inspection apparatus in a nuclear reactor vessel

    International Nuclear Information System (INIS)

    Burns, D.C.

    1979-01-01

    Positioning means for locating inspection apparatus used to volumetrically examine a nuclear reactor vessel is disclosed. The positioning means is provided with a support ring having an annular key positioned longitudinally about its periphery. Three support legs are attached to the support ring by brackets adapted to fit the annular key. The support ring also carries three guide stud bushings which are movably mounted by clamps adapted to engage the support ring key. Prior to lowering the inspection apparatus into the vessel, the guide stud bushings are each moved to a point of alignment with one of three guide studs extending upwardly from the vessel. After alignment has been verified, the guide stud bushings are clamped in position. The inspection apparatus is lowered towards its fully seated position within the vessel and is coarsely circumferentially positioned with by the engagement of the guide studs within the guide stud bushings. A fine degree of circumferential positioning is achieved by providing a specially configured shoe for one of the support legs. With the core barrel internals in, the special shoe is adapted to key onto a core barrel pin the exact location of which is known. With the core barrel internals removed, the special shoe is adapted to place a locating key into a notch in a vessel flange, the location of which is known. As the inspection apparatus is lowered into its fully seated position, exact circumferential positioning with respect to the vessel is achieved. The other support legs rest on an inner circumferential flange so that no portion of the inspection apparatus touches or threatens the vessel's top flange. 19 claims

  10. Homocyst(e)ine impairs endocardial endothelial function.

    Science.gov (United States)

    Tyagi, S C; Smiley, L M; Mujumdar, V S

    1999-12-01

    Homocyst(e)ine injured vascular endothelium and modulated endothelial-dependent vascular function. Endothelium plays an analogous role in both the vessel and the endocardium. Therefore, we hypothesized that homocyst(e)ine modulated endocardial endothelium (EE) dependent cardiac function. The ex vivo cardiac rings from normal male Wistar-Kyoto rats were prepared. The contractile responses of left and right ventricular rings were measured in an isometric myobath, using different concentrations of CaCl2. The response was higher in the left ventricle than right ventricle and was elevated in endocardium without endothelium. The half effective concentration (EC50) and maximum tension generated by homocyst(e)ine were 10(6) and 5-fold lower than endothelin (ET) and angiotensin II (AII), respectively. However, in endothelial-denuded endocardium, homocyst(e)ine response was significantly increased (pine, and endothelial nitric oxide in EE function, cardiac rings were pretreated with AII (10(-10) M) or ET (10(-13) M) and then treated with homocyst(e)ine (10(-8) M). Results suggested that at these concentrations AII, ET, or homocyst(e)ine alone had no effect on cardiac contraction. However, in the presence of 10(-10) M AII or 10(-13) M ET, the cardiac contraction to homocyst(e)ine (10(-8) M) was significantly enhanced (pine. These results suggested that homocyst(e)ine impaired EE-dependent cardiac function and acted synergistically with AII and ET in enhancing the cardiac contraction.

  11. DETERMINATION OF EFFICIENCY OF THE CIRCUMFERENTIAL DRAINAGE SYSTEM

    Directory of Open Access Journals (Sweden)

    Maciej Kroll

    2015-11-01

    Full Text Available One of the potential alternatives to improve the stability coefficient for an embankment structure is to flatten the filtration curve. As a result, we obtain lower body forces triggering the potential landslide and more advantageous soil strength parameters, which counteract landslide movements. In the case of waste dumps lowering the phreatic surface of waters is achieved thanks to the construction of auxiliary drainage systems, meeting the guidelines for their safe operation. The aim of this paper is to indicate a method facilitating the determination of the actual position of the phreatic surface within the deposited sediments and the assessment of efficiency of the circumferential drainage system in the waste dump. It was decided in this study to apply cone penetration test CPTU. The CPTU made it possible to measure dissipation of excess water pressure in pores identifying drainage conditions, which were compared with the results of piezometric measurements. The results of these tests made it possible to monitor changes in the position of the depression curve of supernatant waters in dams and to determine the efficiency of the circumferential drainage system.

  12. On guided circumferential waves in soft electroactive tubes under radially inhomogeneous biasing fields

    Science.gov (United States)

    Wu, Bin; Su, Yipin; Chen, Weiqiu; Zhang, Chuanzeng

    2017-02-01

    Soft electroactive (EA) tube actuators and many other cylindrical devices have been proposed recently in literature, which show great advantages over those made from conventional hard solid materials. However, their practical applications may be limited because these soft EA devices are prone to various failure modes. In this paper, we present an analysis of the guided circumferential elastic waves in soft EA tube actuators, which has potential applications in the in-situ nondestructive evaluation (NDE) or online structural health monitoring (SHM) to detect structural defects or fatigue cracks in soft EA tube actuators and in the self-sensing of soft EA tube actuators based on the concept of guided circumferential elastic waves. Both circumferential SH and Lamb-type waves in an incompressible soft EA cylindrical tube under inhomogeneous biasing fields are considered. The biasing fields, induced by the application of an electric voltage difference to the electrodes on the inner and outer cylindrical surfaces of the EA tube in addition to an axial pre-stretch, are inhomogeneous in the radial direction. Dorfmann and Ogden's theory of nonlinear electroelasticity and the associated linear theory for small incremental motion constitute the basis of our analysis. By means of the state-space formalism for the incremental wave motion along with the approximate laminate technique, dispersion relations are derived in a particularly efficient way. For a neo-Hookean ideal dielectric model, the proposed approach is first validated numerically. Numerical examples are then given to show that the guided circumferential wave propagation characteristics are significantly affected by the inhomogeneous biasing fields and the geometrical parameters. Some particular phenomena such as the frequency veering and the nonlinear dependence of the phase velocity on the radial electric voltage are discussed. Our numerical findings demonstrate that it is feasible to use guided circumferential

  13. Repair of Double Orifice Left AV Valve (DOLAVV with Endocardial Cushion Defect in Adult

    Directory of Open Access Journals (Sweden)

    Vivek Velayudhan Pillai

    Full Text Available Abstract Double orifice left atrioventricular valve (DOLAVV or double orifice mitral valve (DOMV is a rare congenital cardiac anomaly manifesting either as an isolated lesion (mitral stenosis or mitral insufficiency or in association with other congenital cardiac defects. Signs of mitral valve disease are usually present along with the symptoms of associated coexistent congenital heart diseases. Mitral insufficiency due to annular dilatation is seen when DOLAVV is associated with endocardial cushion defects. Surgical intervention like mitral valve repair or replacement is required in 50% of patients and yields good results. We report a case of a 56-year-old lady who successfully underwent surgical correction of DOLAVV with partial atrioventricular canal defect.

  14. Comparison of instrumented anterior interbody fusion with instrumented circumferential lumbar fusion.

    Science.gov (United States)

    Madan, S S; Boeree, N R

    2003-12-01

    Posterior lumbar interbody fusion (PLIF) restores disc height, the load bearing ability of anterior ligaments and muscles, root canal dimensions, and spinal balance. It immobilizes the painful degenerate spinal segment and decompresses the nerve roots. Anterior lumbar interbody fusion (ALIF) does the same, but could have complications of graft extrusion, compression and instability contributing to pseudarthrosis in the absence of instrumentation. The purpose of this study was to assess and compare the outcome of instrumented circumferential fusion through a posterior approach [PLIF and posterolateral fusion (PLF)] with instrumented ALIF using the Hartshill horseshoe cage, for comparable degrees of internal disc disruption and clinical disability. It was designed as a prospective study, comparing the outcome of two methods of instrumented interbody fusion for internal disc disruption. Between April 1994 and June 1998, the senior author (N.R.B.) performed 39 instrumented ALIF procedures and 35 instrumented circumferential fusion with PLIF procedures. The second author, an independent assessor (S.M.), performed the entire review. Preoperative radiographic assessment included plain radiographs, magnetic resonance imaging (MRI) and provocative discography in all the patients. The outcome in the two groups was compared in terms of radiological improvement and clinical improvement, measured on the basis of improvement of back pain and work capacity. Preoperatively, patients were asked to fill out a questionnaire giving their demographic details, maximum walking distance and current employment status in order to establish the comparability of the two groups. Patient assessment was with the Oswestry Disability Index, quality of life questionnaire (subjective), pain drawing, visual analogue scale, disability benefit, compensation status, and psychological profile. The results of the study showed a satisfactory outcome (scorelife questionnaire) score of 71.8% (28 patients) in

  15. Dynamic circumferential ductile crack motion in finite length pipes with various end loadings

    International Nuclear Information System (INIS)

    Emery, A.F.; Kobayashi, A.S.; Love, W.J.; Perl, M.; Kistler, B.

    1981-01-01

    The computed time history, crack opening shape and tip velocity are presented for the ductile crack extension of circumferential cracks in finite length pipes. The pipes are loaded by: a) constant axial tension, b) constant axial displacement, c) constant end moment, and d) constant end rotation to study the effects of these significantly different types of loads. The crack extension is based upon a critical crack opening angle criterion. The results indicate that the extent of the crack movement and the extension velocity is primarily dependent upon the inertia of the moving pipe segments. With sufficient linear momentum, complete severance is obtained, while if the movement is more rotation than translation the cracks either do not extend or do so only slightly. Thus in tougher material, once it begins to extend, the crack may easily encircle the pipe while in more brittle materials it may not, since the moving segments of the pipe have not had time to develop sufficient momentum to force the continued extension of the crack into regions which are initially in compression. (orig.)

  16. Crack-opening area calculations for circumferential through-wall pipe cracks

    Energy Technology Data Exchange (ETDEWEB)

    Kishida, K.; Zahoor, A.

    1988-08-01

    This report describes the estimation schemes for crack opening displacement (COD) of a circumferential through-wall crack, then compares the COD predictions with pipe experimental data. Accurate predictions for COD are required to reliably predict the leak rate through a crack in leak-before-break applications.

  17. Crack-opening area calculations for circumferential through-wall pipe cracks

    International Nuclear Information System (INIS)

    Kishida, K.; Zahoor, A.

    1988-08-01

    This report describes the estimation schemes for crack opening displacement (COD) of a circumferential through-wall crack, then compares the COD predictions with pipe experimental data. Accurate predictions for COD are required to reliably predict the leak rate through a crack in leak-before-break applications

  18. A Critical Appraisal of Circumferential Resection Margins in Esophageal Carcinoma

    NARCIS (Netherlands)

    Pultrum, Bareld B.; Honing, Judith; Smit, Justin K.; van Dullemen, Hendrik M.; van Dam, Gooitzen M.; Groen, Henk; Hollema, Harry; Plukker, John Th. M.

    In esophageal cancer, circumferential resection margins (CRMs) are considered to be of relevant prognostic value, but a reliable definition of tumor-free CRM is still unclear. The aim of this study was to appraise the clinical prognostic value of microscopic CRM involvement and to determine the

  19. Crack resistance of austenitic pipes with circumferential through-wall cracks

    International Nuclear Information System (INIS)

    Foerster, K.; Grueter, L.; Setz, W.; Bhandari, S.; Debaene, J.P.; Faidy, C.; Schwalbe, K.H.

    1993-01-01

    For monotonously increasing load the correct evaluation of the crack resistance properties of a structure is essential for safety analyses. Considerable attention has been given to the through-wall case, since this is generally believed to be the controlling case with regard to complete pipe failure. The maximum load conditions for circumferential crack growth in pipes under displacement-controlled loadings has been determined. The need for crack resistance curves, measured on circumferentially through-wall cracked straight pipes of austenitic stainless steel 316L under bending, is emphasized by the limitation in the data range on small specimens and by the differences in the procedures. To answer open questions and to improve calculational methods a joint fracture mechanics program is being performed by Electricite de France, Novatome and Siemens-Interatom. The working program contains experimental and theoretical investigations on the applicability of small-specimen data to real structures. 10 refs., 10 figs., 4 tabs

  20. Finite Element Limit Pressures for Circumferential Through-Wall Cracks in the Interface between Elbow and Pipe

    International Nuclear Information System (INIS)

    Jang, Yoon-Young; Han, Tae-Song; Huh, Nam-Su; Jeong, Jae-Uk

    2014-01-01

    Among integrity assessment method based on a fracture mechanics concept for piping system, a limit load method is one of the important way to predict a maximum load carrying capacity in the materials with high ductility in the sense that it is used to either assess directly structural integrity of pipe based on fully plastic fracture mechanics or calculate elasticplastic fracture mechanics parameters based on reference stress concept. In nuclear power plants, piping system often involves elbows welded to straight pipe. Since welded regions are vulnerable to cracking, it is important to predict an accurate limit load for pipes with a crack in the interface between elbows and attached pipes. However, although extensive works have been made for developing limit analysis methods for cracked pipes, they were mainly for straight pipes. Recently, limit moment solutions for elbow that is attached to straight pipe with a circumferential through-wall crack(TWC) in the interface were proposed, whereas limit pressure for this geometry is not suggested yet. In this context, plastic limit pressures of circumferential TWCs between elbow and straight pipe were calculated in the present study considering geometric parameters such as an elbow curvature, a pipe size and a crack length. In the present study, the FE plastic limit analyses for circumferential TWC in the interface between elbow and pipe under internal pressure were conducted based on elastic perfectly plastic assumption. Based on the present FE results, it is found that plastic limit pressures of straight pipes with circumferential TWC are not appropriate for predicting plastic limit pressures of circumferential TWC in the interface between elbow and pipe for shorter crack length

  1. Fracture toughness evaluation of circumferentially-cracked round bars

    International Nuclear Information System (INIS)

    Scibetta, M.

    1996-05-01

    The measure of the fracture toughness of a circumferentially-cracked round bar is generally performed through approximate formulae. Comparison of existing formulae to finite element results does not always show good agreement. Therefore an eta factor is introduced in order to improve the existing analytical formula. The axisymmetrical geometry is generally considered to be a high constrained geometry. Finite element calculations are performed to verify and quantify the constraint relative to the three point bending configuration (precracked Charpy)

  2. Endocardial-epicardial distribution of myocardial perfusion reserve assessed by multidetector computed tomography in symptomatic patients without significant coronary artery disease

    DEFF Research Database (Denmark)

    Kühl, Jørgen Tobias; George, Richard T; Mehra, Vishal C

    2016-01-01

    (MPR) in humans. We aimed to test the hypothesis that MPR in all myocardial layers is determined by age, gender, and cardiovascular risk profile in patients with ischaemic symptoms or equivalent but without obstructive coronary artery disease (CAD). METHODS AND RESULTS: A total of 149 patients enrolled...... in endocardial-epicardial distribution of perfusion reserve may be demonstrated with static CT perfusion. Low MPR in all myocardial layers was observed specifically in obese patients....

  3. Validation of the Predicted Circumferential and Radial Mode Sound Power Levels in the Inlet and Exhaust Ducts of a Fan Ingesting Distorted Inflow

    Science.gov (United States)

    Koch, L. Danielle

    2012-01-01

    Fan inflow distortion tone noise has been studied computationally and experimentally. Data from two experiments in the NASA Glenn Advanced Noise Control Fan rig have been used to validate acoustic predictions. The inflow to the fan was distorted by cylindrical rods inserted radially into the inlet duct one rotor chord length upstream of the fan. The rods were arranged in both symmetric and asymmetric circumferential patterns. In-duct and farfield sound pressure level measurements were recorded. It was discovered that for positive circumferential modes, measured circumferential mode sound power levels in the exhaust duct were greater than those in the inlet duct and for negative circumferential modes, measured total circumferential mode sound power levels in the exhaust were less than those in the inlet. Predicted trends in overall sound power level were proven to be useful in identifying circumferentially asymmetric distortion patterns that reduce overall inlet distortion tone noise, as compared to symmetric arrangements of rods. Detailed comparisons between the measured and predicted radial mode sound power in the inlet and exhaust duct indicate limitations of the theory.

  4. Primary cardiac tumor presenting as left ventricular outflow tract obstruction and complex arrhythmia.

    Science.gov (United States)

    Fries, R; Achen, S; O'Brien, M T; Jackson, N D; Gordon, S

    2017-10-01

    An adult female mixed breed dog presented for recurrent collapsing episodes over several weeks. Holter evaluation revealed periods of sinus arrest and echocardiography identified a soft tissue mass with subsequent severe dynamic obstruction of the left ventricular outflow tract. The patient was euthanized five days after presentation for severe dyspnea. Necropsy revealed an irregular mass circumferentially lining the left ventricular outflow tract as well as multiple myocardial metastases. The final diagnosis was an undifferentiated pleomorphic endocardial sarcoma. Published by Elsevier B.V.

  5. Net-section limit moments and approximate J estimates for circumferential cracks at the interface between elbows and pipes

    International Nuclear Information System (INIS)

    Song, Tae-Kwang; Kim, Yun-Jae; Oh, Chang-Kyun; Jin, Tae-Eun; Kim, Jong-Sung

    2009-01-01

    This paper firstly presents net-section limit moments for circumferential through-wall and part-through surface cracks at the interface between elbows and attached straight pipes under in-plane bending. Closed-form solutions are proposed based on fitting results from small strain FE limit analyses using elastic-perfectly plastic materials. Net-section limit moments for circumferential cracks at the interface between elbows and attached straight pipes are found to be close to those for cracks in the centre of elbows, implying that the location of the circumferential crack within an elbow has a minimal effect on the net-section limit moment. Accordingly it is also found that the assumption that the crack locates in a straight pipe could significantly overestimate the net-section limit load (and thus maximum load-carrying capacity) of the cracked component. Based on the proposed net-section limit moment, a method to estimate elastic-plastic J based on the reference stress approach is proposed for circumferential cracks at the interface between elbows and attached straight pipes under in-plane bending.

  6. Failure Assessment for the High-Strength Pipelines with Constant-Depth Circumferential Surface Cracks

    Directory of Open Access Journals (Sweden)

    X. Liu

    2018-01-01

    Full Text Available In the oil and gas transportation system over long distance, application of high-strength pipeline steels can efficiently reduce construction and operation cost by increasing operational pressure and reducing the pipe wall thickness. Failure assessment is an important issue in the design, construction, and maintenance of the pipelines. The small circumferential surface cracks with constant depth in the welded pipelines are of practical interest. This work provides an engineering estimation procedure based upon the GE/EPRI method to determine the J-integral for the thin-walled pipelines with small constant-depth circumferential surface cracks subject to tension and bending loads. The values of elastic influence functions for stress intensity factor and plastic influence functions for fully plastic J-integral estimation are derived in tabulated forms through a series of three-dimensional finite element calculations for different crack geometries and material properties. To check confidence of the J-estimation solution in practical application, J-integral values obtained from detailed finite element (FE analyses are compared with those estimated from the new influence functions. Excellent agreement of FE results with the proposed J-estimation solutions for both tension and bending loads indicates that the new solutions can be applied for accurate structural integrity assessment of high-strength pipelines with constant-depth circumferential surface cracks.

  7. Ductile fracture of circumferentially cracked pipes subjected to bending loads

    International Nuclear Information System (INIS)

    Zahoor, A.; Kanninen, M.F.

    1981-01-01

    A plastic fracture mechanics methodology is presented for part-through cracks in pipes under bending. A previous analysis result on the behavior of part-through cracks in pipes is reviewed. Example quantitative results for the initiation and instability of radial growth of part-through cracks are presented and compared with the experimental data to demonstrate the applicability of the method. The analyses in our previous work are further developed to include the instability of circumferential growth of part-through cracks. Numerical results are then presented for a compliant piping system, under displacement controlled bending, which focus on (1) instability of radial growth (unstable wall breakthrough) and (2) instability of circumferential growth of the resulting throughthe-thickness crack. The combined results of the above two types of analyses are presented on a safety assessment diagram. This diagram defines a curve of critical combination of length and depth of part-through cracks which delineates leak from fracture. The effect of piping compliance on the leak-before-break assessment is discussed

  8. Ductile fracture of circumferentially cracked pipes subjected to bending loads

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.; Kanninen, M.F.

    1981-10-01

    A plastic fracture mechanics methodology is presented for part-through cracks in pipes under bending. A previous analysis result on the behavior of part-through cracks in pipes is reviewed. Example quantitative results for the initiation and instability of radial growth of part-through cracks are presented and compared with the experimental data to demonstrate the applicability of the method. The analyses in our previous work are further developed to include the instability of circumferential growth of part-through cracks. Numerical results are then presented for a compliant piping system, under displacement controlled bending, which focus on (1) instability of radial growth (unstable wall breakthrough) and (2) instability of circumferential growth of the resulting throughthe-thickness crack. The combined results of the above two types of analyses are presented on a safety assessment diagram. This diagram defines a curve of critical combination of length and depth of part-through cracks which delineates leak from fracture. The effect of piping compliance on the leak-before-break assessment is discussed.

  9. AMPTRACT: an algebraic model for computing pressure tube circumferential and steam temperature transients under stratified channel coolant conditions

    International Nuclear Information System (INIS)

    Gulshani, P.; So, C.B.

    1986-10-01

    In a number of postulated accident scenarios in a CANDU reactor, some of the horizontal fuel channels are predicted to experience periods of stratified channel coolant condition which can lead to a circumferential temperature gradient around the pressure tube. To study pressure tube strain and integrity under stratified flow channel conditions, it is, necessary to determine the pressure tube circumferential temperature distribution. This paper presents an algebraic model, called AMPTRACT (Algebraic Model for Pressure Tube TRAnsient Circumferential Temperature), developed to give the transient temperature distribution in a closed form. AMPTRACT models the following modes of heat transfer: radiation from the outermost elements to the pressure tube and from the pressure to calandria tube, convection between the fuel elements and the pressure tube and superheated steam, and circumferential conduction from the exposed to submerged part of the pressure tube. An iterative procedure is used to solve the mass and energy equations in closed form for axial steam and fuel-sheath transient temperature distributions. The one-dimensional conduction equation is then solved to obtain the pressure tube circumferential transient temperature distribution in a cosine series expansion. In the limit of large times and in the absence of convection and radiation to the calandria tube, the predicted pressure tube temperature distribution reduces identically to a parabolic profile. In this limit, however, radiation cannot be ignored because the temperatures are generally high. Convection and radiation tend to flatten the parabolic distribution

  10. Determination of the axial and circumferential mechanical properties of the skin tissue using experimental testing and constitutive modeling.

    Science.gov (United States)

    Karimi, Alireza; Navidbakhsh, Mahdi; Haghighatnama, Maedeh; Haghi, Afsaneh Motevalli

    2015-01-01

    The skin, being a multi-layered material, is responsible for protecting the human body from the mechanical, bacterial, and viral insults. The skin tissue may display different mechanical properties according to the anatomical locations of a body. However, these mechanical properties in different anatomical regions and at different loading directions (axial and circumferential) of the mice body to date have not been determined. In this study, the axial and circumferential loads were imposed on the mice skin samples. The elastic modulus and maximum stress of the skin tissues were measured before the failure occurred. The nonlinear mechanical behavior of the skin tissues was also computationally investigated through a suitable constitutive equation. Hyperelastic material model was calibrated using the experimental data. Regardless of the anatomic locations of the mice body, the results revealed significantly different mechanical properties in the axial and circumferential directions and, consequently, the mice skin tissue behaves like a pure anisotropic material. The highest elastic modulus was observed in the back skin under the circumferential direction (6.67 MPa), while the lowest one was seen in the abdomen skin under circumferential loading (0.80 MPa). The Ogden material model was narrowly captured the nonlinear mechanical response of the skin at different loading directions. The results help to understand the isotropic/anisotropic mechanical behavior of the skin tissue at different anatomical locations. They also have implications for a diversity of disciplines, i.e., dermatology, cosmetics industry, clinical decision making, and clinical intervention.

  11. ELESTRES: performance of nuclear fuel, circumferential ridging, and multiaxial elastic-plastic stresses in sheaths

    International Nuclear Information System (INIS)

    Tayal, M.

    1986-10-01

    The finite element code ELESTRES models the two-dimensional axisymmetric behaviour of a CANDU fuel element during normal operation. The main focus of the code is to estimate temperatures, fission gas release, and axial variations of deformation/stresses in the pellet and in the sheath. Thus the code is able to predict details like stresses/strains at circumferential ridges. This paper describes the current version of ELESTRES. The emphasis is on a recent addition: multiaxial stresses in the sheath near circumferential ridges. For accuracy in the critical region, a fine mesh is used near the ridge. To keep computing costs low, a coarse mesh is used near the midplane of the pellet. Predictions of ELESTRES show good agreement with abouth 80 measurements of fission-gas-release. In this paper, we also present ELESTRES predictions of hoop strains in sheaths, for two irradiations: element ABS and bundle GB. For both irradiations, predictions, compare favourably with measurements. An illustrative example shows that near circumferential ridges, bending contributes to multiaxial stresses in the sheath. This can have a significant effect on sheath integrity, such as during stress-corrosion-cracking due to power-increases, or during corrosion-assisted-fatigue due to power cycling

  12. Esophageal circumferential en bloc endoscopic submucosal dissection: assessment of a new technique.

    Science.gov (United States)

    Barret, Maximilien; Pratico, Carlos Alberto; Beuvon, Frédéric; Mangialavori, Luigi; Chryssostalis, Ariane; Camus, Marine; Chaussade, Stanislas; Prat, Frédéric

    2013-10-01

    Endoscopic esophageal piecemeal mucosectomy for high-grade dysplasia on Barrett's esophagus leads to suboptimal histologic evaluation, as well as recurrence on remaining mucosa. Circumferential en bloc mucosal resection would significantly improve the management of dysplastic Barrett's esophagus. Our aim was to describe a new method of esophageal circumferential endoscopic en bloc submucosal dissection (CESD) in a swine model. After submucosal injection, circumferential incision was performed at each end of the esophageal segment to be removed. Mechanical submucosal dissection was performed from the proximal to the distal incision, using a mucosectomy cap over the endoscope. The removed mucosal ring was retrieved. Clinical, endoscopic, and histologic data were prospectively collected. Esophageal CESD was conducted on 5 pigs. A median mucosal length of 6.5 cm (range, 4 to 8 cm) was removed in the lower third of the esophagus. The mean duration of the procedure was 36 minutes (range, 17 to 80 min). No procedure-related complication, including perforation, was observed. All animals exhibited a mild esophageal stricture at day 7, and a severe symptomatic stricture at day 14. Necropsy confirmed endoscopic findings with cicatricial fibrotic strictures. On histologic examination, an inflammatory cell infiltrate, diffuse fibrosis reaching the muscular layer, and incomplete reepithelialization were observed. CESD enables expeditious resection and thorough examination of large segments of esophageal mucosa in safe procedural conditions, but esophageal strictures occur in the majority of the cases. Efficient methods for stricture prevention are needed for this technique to be developed in humans.

  13. Variation in circumferential resection margin: Reporting and involvement in the South-Netherlands

    NARCIS (Netherlands)

    Homan, J.; Bokkerink, G.M.J.; Aarts, M.J.; Lemmens, V.E.; Lijnschoten, G. van; Rutten, H.J.; Wijsman, J.H.; Nagtegaal, I.D.; Wilt, J.H.W. de

    2015-01-01

    BACKGROUND: Since the introduction of total mesorectal surgery the outcome of rectal cancer patients has improved significantly. Involvement of the circumferential resection margin (CRM) is an important predictor of increased local recurrence, distant metastases and decreased overall survival.

  14. ISSLS prize winner: cost-effectiveness of two forms of circumferential lumbar fusion

    DEFF Research Database (Denmark)

    Freeman, Brian J C; Steele, Nicholas A; Sach, Tracey H

    2007-01-01

    employment was also monitored. Bootstrapped mean differences in discounted costs and benefits were generated in order to explore cost-effectiveness. RESULTS: A significant cost difference of pound 1950 (95% CI, pound 849 to pound 3145) in favor of FRA was found. Mean QALYs per patient over the 24-month trial......STUDY DESIGN: Economic evaluation alongside a prospective, randomized controlled trial from a secondary care National Health Service (NHS) perspective. OBJECTIVE: To determine the cost-effectiveness of titanium cages (TC) compared with femoral ring allografts (FRA) in circumferential lumbar spinal...... is less effective and, all things being equal, is assumed more costly than FRA. METHODS: Eighty-three patients were randomly allocated to receive either the TC or FRA as part of a circumferential lumbar fusion between 1998 and 2002. NHS costs related to the surgery and revision surgery needed during...

  15. Circumferential Ciliary Body Cysts Presenting as Acute Pigment Dispersion and Ocular Hypertension.

    Science.gov (United States)

    Sarıgül Sezenöz, Almila; Güngör, Sirel Gür; Kıratlı, Hayyam; Akman, Ahmet

    2017-09-15

    To report a case of circumferential neuroepithelial cyst of the ciliary body presenting with pigment dispersion (PD) and ocular hypertension. 48-year-old female patient presented with a complaint of pain in the left eye. On examination, visual acuity of the left eye was 0.9, and the intraocular pressure was 48 mmHg. Biomicroscopic anterior segment examination of the left eye revealed 4+ pigmented cells in the anterior chamber. Active PD from the pupillary region at 11 o'clock was noticed at the time of the examination. Ultrasound biomicroscopy demonstrated 360º cystic lesions of the ciliary body in the left eye. The patient was diagnosed as neuroepithelial cyst of the ciliary body. Our case is unique as it is the first case of circumferential neuroepithelial ciliary body cyst presenting with acute PD and ocular hypertension.

  16. Elastic-Plastic Fracture Mechanics Analyses for Circumferential Part-Through Surface Cracks at the Interface Between elbows and Pipes

    International Nuclear Information System (INIS)

    Song, Tae Kwang; Oh, Chang Kyun; Kim, Yun Jae; Kim, Jong Sung; Jin, Tae Eun

    2007-01-01

    This paper presents plastic limit loads and approximate J-integral estimates for circumferential part-through surface crack at the interface between elbows and pipes. Based on finite element limit analyses using elastic-perfectly plastic materials, plastic limit moments under in-plane bending are obtained and it is found that they are similar those for circumferential part-through surface cracks in the center of elbow. Based on present FE results, closed-form limit load solutions are proposed. Welds are not explicitly considered and all materials are assumed to be homogeneous. And the method to estimate the elastic-plastic J-integral for circumferential part-through surface cracks at the interface between elbows and straight pipes is proposed based on the reference stress approach, which was compared with corresponding solutions for straight pipes

  17. Elastic-Plastic Fracture Mechanics Analyses For circumferential Part-through Surface Cracks At The Interface Between Elbows and Pipes

    International Nuclear Information System (INIS)

    Song, Tae Kwang; Kim, Yun Jae; Oh, Chang Kyun; Kim, Jong Sung; Jin, Tae Eun

    2007-01-01

    This paper presents plastic limit loads and approximate J-integral estimates for circumferential part-through surface crack at the interface between elbows and pipes. Based on finite element limit analyses using elastic-perfectly plastic materials, plastic limit moments under in-plane bending are obtained and it is found that they are similar those for circumferential part-through surface cracks in the center of elbow. Based on present FE results, closed-form limit load solutions are proposed. Welds are not explicitly considered and all materials are assumed to be homogeneous. And the method to estimate the elastic-plastic J-integral for circumferential part-through surface cracks at the interface between elbows and straight pipes is proposed based on the reference stress approach, which was compared with corresponding solutions for straight pipes

  18. Low cycle fatigue of pressurized pipes with circumferential flaws under cyclic bending moment

    International Nuclear Information System (INIS)

    Stoppler, W.; Sturm, D.

    1993-01-01

    Pipes of 706 mm inner diameter, 47 mm wall thickness and about 5,000 mm in length were provided with circumferential surface cracks and loaded by internal pressure of 15 MPa whilst being simultaneously subjected to an alternating external bending moment. Usually a load ratio R of -1 (M min /M max ), in one case R = 0.1, was applied. The pipes were fabricated of two types of ferritic steel: one, grade 20 MnMoNi 5 5, with a high upper shelf impact energy of about 200 J and one, MnMoNiV-special melt, with a low upper shelf impact energy of about 60 J. Deformation and crack growth in the wall thickness and circumferential direction were determined and compared with calculated values. 9 refs., 13 figs

  19. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  20. J-integral estimation analysis for circumferential throughwall cracked pipes

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.

    J-integral estimation solution is derived for pipes containing a circumferential throughwall crack. Bending moment and axial tension loadings are considered. These solutions are useful for calculating J from single load-displacement record obtained as part of pipe fracture testing, and are applicable for a wide range of flaw length to pipe circumference ratios. Results for J at initiation of crack growth generated using the solution developed in this paper agree well with J results from finite elements analyses.

  1. A floating right heart thrombus in transit across tricuspid valve causing an endocardial friction rub

    Directory of Open Access Journals (Sweden)

    Babu Kanjirakadavath

    2013-07-01

    Full Text Available We report a 42-year-old lady on combined oral contraceptive pills with deep venous thrombosis and mild pulmonary embolism, who developed shock, while being treated with heparin. On auscultation, there was an unexpected loud, superficial, squeaky, triphasic friction rub over the left lower parasternal area. Simultaneous echocardiogram revealed a large serpiginous, freely floating mass in right atrium, prolapsing freely to right ventricular inlet across the tricuspid valve. The endocardial friction rub persisted for about 24 h as long as the thrombus was intracardiac and disappeared when the thrombus disappeared from right heart, occluding the proximal left pulmonary artery. She died due to shock awaiting surgery. We highlight that such a rub in a patient with deep venous thrombosis, though rare, may be an important clue to impending pulmonary embolism.

  2. Automated circumferential construction of first-order aqueous humor outflow pathways using spectral-domain optical coherence tomography.

    Science.gov (United States)

    Huang, Alex S; Belghith, Akram; Dastiridou, Anna; Chopra, Vikas; Zangwill, Linda M; Weinreb, Robert N

    2017-06-01

    The purpose was to create a three-dimensional (3-D) model of circumferential aqueous humor outflow (AHO) in a living human eye with an automated detection algorithm for Schlemm’s canal (SC) and first-order collector channels (CC) applied to spectral-domain optical coherence tomography (SD-OCT). Anterior segment SD-OCT scans from a subject were acquired circumferentially around the limbus. A Bayesian Ridge method was used to approximate the location of the SC on infrared confocal laser scanning ophthalmoscopic images with a cross multiplication tool developed to initiate SC/CC detection automated through a fuzzy hidden Markov Chain approach. Automatic segmentation of SC and initial CC’s was manually confirmed by two masked graders. Outflow pathways detected by the segmentation algorithm were reconstructed into a 3-D representation of AHO. Overall, only time and time with 1.4% false positive detection. 3-D representation of AHO pathways demonstrated variably thicker and thinner SC with some clear CC roots. Circumferential (360 deg), automated, and validated AHO detection of angle structures in the living human eye with reconstruction was possible.

  3. Functional evaluation of repairs to circumferential labral lesions of the glenoid - Case series

    Directory of Open Access Journals (Sweden)

    Alexandre Tadeu do Nascimento

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the clinical results among patients undergoing arthroscopic repair of circumferential labral lesions. METHODS: This was a retrospective study on 10 patients who underwent arthroscopic repair to circumferential labral lesions of the shoulder, between September 2012 and September 2015. The patients were evaluated by means of the Carter-Rowe score, DASH score, UCLA score, visual analog scale (VAS for pain and Short-Form 36 (SF36. The average age at surgery was 29.6 years. The mean follow-up was 27.44 months (range: 12-41.3. RESULTS: The mean score was 16 points for DASH; 32 points for UCLA, among which six patients (60% had excellent results, three (30% good and one (10% poor; 1.8 points for VAS, among which nine patients (90% had minor pain and one (10% moderate pain; 79.47 for SF-36; and 92.5 for Carter-Rowe, among which nine patients (90% had excellent results and one (10% good. Joint degeneration was present in one case (10%, of grade 1. We did not observe any significant complications, except for grade 1 glenohumeral arthrosis, which one patient developed after the operation. CONCLUSION: Arthroscopic repair of circumferential labral lesions of the shoulder through use of absorbable anchors is effective, with improvements in all scores applied, and it presents low complication rates. Cases associated with glenohumeral dislocation have lower long-term residual pain.

  4. J-integral estimation analysis for circumferential throughwall cracked pipes

    International Nuclear Information System (INIS)

    Zahoor, A.

    1988-01-01

    J-integral estimation solution is derived for pipes containing a circumferential throughwall crack. Bending moment and axial tension loadings are considered. These solutions are useful for calculating J from single load-displacement record obtained as part of pipe fracture testing, and are applicable for a wide range of flaw length to pipe circumference ratios. Results for J at initiation of crack growth generated using the solution developed in this paper agree well with J results from finite elements analyses. (orig.)

  5. Improved circumferential shaft seal for aircraft gear transmissions

    Science.gov (United States)

    Ludwig, L. P.; Strom, T. N.

    1973-01-01

    Operation under simulated aircraft transmission conditions of speeds to 2850 m/min (9350 ft/min), lubricant temperatures to 394 K (250 F), shaft radial runouts to 0.254 mm (0.010 in.) F.I.R. (full indicator reading), and pressure differentials to 1.03 N/cm2 (1.5 psi) revealed that conventional circumferential seals leaked excessively. Modifying the conventional seal by adding helical grooves to the seal bore reduced leakage rates to within the acceptable level of 10 cm3/hr. The leakage rate of this modified seal was not significantly affected by lubricant flooding or by shaft radial runout.

  6. Complete 360° circumferential SSOCT gonioscopy of the iridocorneal angle

    Science.gov (United States)

    McNabb, Ryan P.; Kuo, Anthony N.; Izatt, Joseph A.

    2014-02-01

    The ocular iridocorneal angle is generally an optically inaccessible area when viewed directly through the cornea due to the high angle of incidence required and the large index of refraction difference between air and cornea (nair = 1.000 and ncornea = 1.376) resulting in total internal reflection. Gonioscopy allows for viewing of the angle by removing the aircornea interface through the use of a special contact lens on the eye. Gonioscopy is used clinically to visualize the angle directly but only en face. Optical coherence tomography (OCT) has been used to image the angle and deeper structures via an external approach. Typically, this imaging technique is performed by utilizing a conventional anterior segment OCT scanning system. However, instead of imaging the apex of the cornea, either the scanner or the subject is tilted such that the corneoscleral limbus is orthogonal to the optical axis of the scanner requiring multiple volumes to obtain complete circumferential coverage of the ocular angle. We developed a novel gonioscopic OCT (GOCT) system that images the entire ocular angle within a single volume via an "internal" approach through the use of a custom radially symmetric gonioscopic contact lens. We present, to our knowledge, the first complete 360° circumferential volumes of the iridocorneal angle from a direct, internal approach.

  7. Effect of surface contamination on osseointegration of dental implants surrounded by circumferential bone defects.

    LENUS (Irish Health Repository)

    Mohamed, Seif

    2010-05-01

    This study was designed to evaluate the effect of surface contamination on osseointegration of dental implants surrounded by a circumferential bone defect and to compare osseointegration around Osseotite with that around Nanotite implants.

  8. Circumferential fusion is dominant over posterolateral fusion in a long-term perspective: cost-utility evaluation of a randomized controlled trial in severe, chronic low back pain

    DEFF Research Database (Denmark)

    Soegaard, Rikke; Bünger, Cody E; Christiansen, Terkel

    2007-01-01

    STUDY DESIGN: Cost-utility evaluation of a randomized, controlled trial with a 4- to 8-year follow-up. OBJECTIVE: To investigate the incremental cost per quality-adjusted-life-year (QALY) when comparing circumferential fusion to posterolateral fusion in a long-term, societal perspective. SUMMARY...... OF BACKGROUND DATA: The cost-effectiveness of circumferential fusion in a long-term perspective is uncertain but nonetheless highly relevant as the ISSLS prize winner 2006 in clinical studies reported the effect of circumferential fusion superior to the effect of posterolateral fusion. A recent trial found...... no significant difference between posterolateral and circumferential fusion reporting cost-effectiveness from a 2-year viewpoint. METHODS: A total of 146 patients were randomized to posterolateral or circumferential fusion and followed 4 to 8 years after surgery. The mean age of the cohort was 46 years (range...

  9. Skin resurfacing in a circumferential full thickness burn to the penis: lessons learnt.

    Science.gov (United States)

    Jabir, Shehab; Frew, Quentin; Thompson, Richard; Dziewulski, Peter

    2013-08-13

    A circumferential full-thickness burn to the penis is a rarely encountered injury. However, when it does occur, it proves a management challenge to the plastic and burns surgeon in terms of reconstruction. This is due to the need of not only regaining adequate function of the organ, but also because of the need for a pleasing aesthetic outcome. Split-skin grafts have been utilised successfully to resurface full thickness burns of the penis and have given good results. Yet the success of split-skin grafts, especially those applied to an anatomically challenging region of the body such as the penis, depends on a number of carefully thought-out steps. We discuss the case of a circumferential full-thickness burn to the penis which was treated with split-skin grafting and highlight important pitfalls that the plastic and burns surgeon need to be aware of to ensure a successful outcome.

  10. Circumferential electrocautery of the patella in primary total knee replacement without patellar replacement: a meta-analysis and systematic review

    Science.gov (United States)

    Fan, Lihong; Ge, Zhaogang; Zhang, Chen; Li, Jia; Yu, Zefeng; Dang, Xiaoqian; Wang, Kunzheng

    2015-03-01

    The purpose of this meta-analysis and systematic review was to identify and assess whether circumferential electrocautery is useful for improving outcomes after primary total knee replacement(TKR). We searched MEDLINE, EMBASE, PubMed, SpringerLink, Web of Knowledge, OVID CINAHL, OVID EBM and Google Scholar and included articles published through January 2014. A total of 6 articles met the inclusion criteria. Of the 776 cases included in the analysis, 388 cases involved patellar denervation, and 388 cases were designated as the control group. The meta-analysis revealed no significant difference in the incidence of anterior knee pain (AKP, p = 0.18) or in the visual analogue scale score (VAS, p = 0.23) between the two groups. In addition, AKSS Function Score indicated no significant difference between the two groups (p = 0.28). However, the OKS (p = 0.02), patellar score (p = 0.01), AKSS-Knee Score (p = 0.004), range of motion (ROM, p electrocautery. The results indicate that circumferential electrocautery of the patella does not significantly improve AKP compared with non-electrocautery techniques but that circumferential electrocautery significantly improves patients' knee function after surgery. Therefore, we believe that circumferential electrocautery is beneficial to the outcome of primary TKR surgery without patellar replacement.

  11. Soft Sensor for Oxide Scales on the Steam Side of Superheater Tubes under Uneven Circumferential Load

    Directory of Open Access Journals (Sweden)

    Qing Wei Li

    2015-01-01

    Full Text Available A soft sensor for oxide scales on the steam side of superheater tubes of utility boiler under uneven circumferential loading is proposed for the first time. First finite volume method is employed to simulate oxide scales growth temperature on the steam side of superheater tube. Then appropriate time and spatial intervals are selected to calculate oxide scales thickness along the circumferential direction. On the basis of the oxide scale thickness, the stress of oxide scales is calculated by the finite element method. At last, the oxide scale thickness and stress sensors are established on support vector machine (SMV optimized by particle swarm optimization (PSO with time and circumferential angles as inputs and oxide scale thickness and stress as outputs. Temperature and stress calculation methods are validated by the operation data and experimental data, respectively. The soft sensor is applied to the superheater tubes of some power plant. Results show that the soft sensor can give enough accurate results for oxide scale thickness and stress in reasonable time. The forecasting model provides a convenient way for the research of the oxide scale failure.

  12. Circumferential scouting punch biopsies to delineate surgical margin for dermatofibrosarcoma protuberans

    Directory of Open Access Journals (Sweden)

    Tsung-Mao Huang

    2012-03-01

    Full Text Available Dermatofibrosarcoma protuberans (DFSP is an uncommon soft-tissue tumor involving the dermis and subcutaneous tissue with a high local recurrence rate after standard excision. Mohs micrographic surgery offers a lower recurrence rate. However, the procedure requires multiple stages of excision with intraoperative histopathological mapping, which is time consuming and expensive. We report our experience of using circumferential scouting punch biopsy technique in five patients to determine in advance the resection margins for DFSP prior to wide excision. Multiple 4 mm punches, usually eight in number, were performed 1–2.5 cm around the palpable borders of DFSP to delineate the resection margins in five consecutive patients. Tumors were excised at a later date along the margin defined by these biopsies and the wounds were repaired with skin graft. The operation was completed in 2 hours in all cases excluding one that required frozen sections for deep margin. No recurrence was noted 2–10 years after the operations. The results suggest that circumferential scouting punch biopsies before wide excision may be an alternative method to define the resection margins for DFSP when Mohs surgery is not available.

  13. Burnout in a channel with non-uniform circumferential heat flux

    International Nuclear Information System (INIS)

    Lee, D.H.

    1966-03-01

    Burnout experiments are reported for uniform flux and circumferential flux tilt (maximum/average flux about 1.25) with tubes and annuli, all the experiments having uniform axial heating. These show similar results, the burnout power with flux tilt being within 10% of that with uniform flux. For the same mean exit steam quality, the local maximum flux is higher than the predicted burnout value and generally a better prediction is obtained using the average flux. (author)

  14. Plastic fracture mechanics prediction of fracture instability in a circumferentially cracked pipe in bending--1. J-integral analysis

    International Nuclear Information System (INIS)

    Zahoor, A.; Kanninen, M.F.

    1980-01-01

    A method of evaluating the J-integral for a circumferentially cracked pipe in bending is proposed. The method allows a J-resistance curve to be evaluated directly from the load-displacement record obtained in a pipe fracture experiment. This method also permits an analysis for fracture instability in a circumferential crack growth using a J-resistance curve and the tearing modulus parameter. The importance of using a J-resistance curve that is consistent with the type of constraint for a given application is emphasized. 18 refs

  15. Quantitative circumferential strain analysis using adenosine triphosphate-stress/rest 3-T tagged magnetic resonance to evaluate regional contractile dysfunction in ischemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Masashi, E-mail: m.nakamura1230@gmail.com [Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon-city, Ehime 791-0295 (Japan); Kido, Tomoyuki [Department of Radiology, Saiseikai Matsuyama Hospital, Ehime 791-0295 (Japan); Kido, Teruhito; Tanabe, Yuki; Matsuda, Takuya; Nishiyama, Yoshiko; Miyagawa, Masao; Mochizuki, Teruhito [Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon-city, Ehime 791-0295 (Japan)

    2015-08-15

    Highlights: • Infarcted segments could be differentiated from non-ischemic and ischemic segments with high sensitivity and specificity under at rest conditions. • The time-to-peak circumferential strain values in infarcted segments were more significantly delayed than those in non-ischemic and ischemic segments. • Both circumferential strain and circumferential systolic strain rate values under ATP-stress conditions were significantly lower in ischemic segments than in non-ischemic segments. • Subtracting stress and rest circumferential strain had a higher diagnostic capability for ischemia relative to only utilizing rest or ATP-stress circumferential strain values. • A circumferential strain analysis using tagged MR can quantitatively assess contractile dysfunction in ischemic and infarcted myocardium. - Abstract: Purpose: We evaluated whether a quantitative circumferential strain (CS) analysis using adenosine triphosphate (ATP)-stress/rest 3-T tagged magnetic resonance (MR) imaging can depict myocardial ischemia as contractile dysfunction during stress in patients with suspected coronary artery disease (CAD). We evaluated whether it can differentiate between non-ischemia, myocardial ischemia, and infarction. We assessed its diagnostic performance in comparison with ATP-stress myocardial perfusion MR and late gadolinium enhancement (LGE)-MR imaging. Methods: In 38 patients suspected of having CAD, myocardial segments were categorized as non-ischemic (n = 485), ischemic (n = 74), or infarcted (n = 49) from the results of perfusion MR and LGE-MR. The peak negative CS value, peak circumferential systolic strain rate (CSR), and time-to-peak CS were measured in 16 segments. Results: A cutoff value of −12.0% for CS at rest allowed differentiation between infarcted and other segments with a sensitivity of 79%, specificity of 76%, accuracy of 76%, and an area under the curve (AUC) of 0.81. Additionally, a cutoff value of 477.3 ms for time-to-peak CS at rest

  16. Plastic fracture instability analysis of wall breakthrough in a circumferentially cracked pipe subjected to bending loads

    International Nuclear Information System (INIS)

    Zahoor, A.; Kanninen, M.F.

    1981-01-01

    A method of analyzing internal surface circumferential cracks in ductile reactor piping is presented. The method utilizes an alternate but equivalent definition of the J-integral based on nonlinear structural compliance. The analysis is valid for situations where the cross section containing the crack is fully yielded. Results are obtained for radial and circumferential crack growth for pipes subjected to bending. The stability of radial crack growth (wall breakthrough) is assessed using the J-integral-based tearing modulus approach. The analysis is shown to be in agreement with experimental results on the stability of surface crack growth in Type 304 stainless stee pipes. Example quantitative results for fracture instability assessments for nuclear piping are presented. 23 refs

  17. Plastic fracture instability analysis of wall breakthrough in a circumferentially cracked pipe subjected to bending loads

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.; Kanninen, M.F.

    1981-07-01

    A method of analyzing internal surface circumferential cracks in ductile reactor piping is presented. The method utilizes an alternate but equivalent definition of the J-integral based on nonlinear structural compliance. The analysis is valid for situations where the cross section containing the crack is fully yielded. Results are obtained for radial and circumferential crack growth for pipes subjected to bending. The stability of radial crack growth (wall breakthrough) is assessed using the J-integral-based tearing modulus approach. The analysis is shown to be in agreement with experimental results on the stability of surface crack growth in Type 304 stainless stee pipes. Example quantitative results for fracture instability assessments for nuclear piping are presented. 23 refs.

  18. Development of new Z-factors for the evaluation of the circumferential surface crack in nuclear pipes

    International Nuclear Information System (INIS)

    Choi, Y.H.; Chung, Y.K.; Park, Y.W.; Lee, J.B.

    1997-01-01

    The purpose of this study is to develop new Z-factors to evaluate the behavior of a circumferential surface crack in nuclear pipe. Z-factor is a load multiplier used in the Z-factor method, which is one of the ASME Code Sec. XI's recommendations for the estimation of a surface crack in nuclear pipe. It has been reported that the load carrying capacities predicted from the current ASME Code Z-factors, are not well in agreement with the experimental results for nuclear pipes with a surface crack. In this study, new Z-factors for ferritic base metal, ferritic submerged arc welding (SAW) weld metal, austenitic base metal, and austenitic SAW weld metal are obtained by use of the surface crack for thin pipe (SC.TNP) method based on GE/EPRI method. The desirability of both the SC.TNP method and the new Z-factors is examined using the results from 48 pipe fracture experiments for nuclear pipes with a circumferential surface crack. The results show that the SC.TNP method is good for describing the circumferential surface crack behavior and the new Z-factors are well in agreement with the measured Z-factors for both ferritic and austenitic pipes. (orig.)

  19. Automated circumferential construction of first-order aqueous humor outflow pathways using spectral-domain optical coherence tomography

    Science.gov (United States)

    Huang, Alex S.; Belghith, Akram; Dastiridou, Anna; Chopra, Vikas; Zangwill, Linda M.; Weinreb, Robert N.

    2017-06-01

    The purpose was to create a three-dimensional (3-D) model of circumferential aqueous humor outflow (AHO) in a living human eye with an automated detection algorithm for Schlemm's canal (SC) and first-order collector channels (CC) applied to spectral-domain optical coherence tomography (SD-OCT). Anterior segment SD-OCT scans from a subject were acquired circumferentially around the limbus. A Bayesian Ridge method was used to approximate the location of the SC on infrared confocal laser scanning ophthalmoscopic images with a cross multiplication tool developed to initiate SC/CC detection automated through a fuzzy hidden Markov Chain approach. Automatic segmentation of SC and initial CC's was manually confirmed by two masked graders. Outflow pathways detected by the segmentation algorithm were reconstructed into a 3-D representation of AHO. Overall, only <1% of images (5114 total B-scans) were ungradable. Automatic segmentation algorithm performed well with SC detection 98.3% of the time and <0.1% false positive detection compared to expert grader consensus. CC was detected 84.2% of the time with 1.4% false positive detection. 3-D representation of AHO pathways demonstrated variably thicker and thinner SC with some clear CC roots. Circumferential (360 deg), automated, and validated AHO detection of angle structures in the living human eye with reconstruction was possible.

  20. Quantitative Differentiation of LV Myocardium with and without Layer-Specific Fibrosis Using MRI in Hypertrophic Cardiomyopathy and Layer-Specific Strain TTE Analysis.

    Science.gov (United States)

    Funabashi, Nobusada; Takaoka, Hiroyuki; Ozawa, Koya; Kamata, Tomoko; Uehara, Masae; Komuro, Issei; Kobayashi, Yoshio

    2018-05-30

    To achieve further risk stratification in hypertrophic cardiomyopathy (HCM) patients, we localized and quantified layer-specific LVM fibrosis on MRI in HCM patients using regional layer-specific peak longitudinal strain (PLS) and peak circumferential strain (PCS) in LV myocardium (LVM) on speckle tracking transthoracic echocardiography (TTE). A total of 18 HCM patients (14 males; 58 ± 17 years) underwent 1.5T-MRI and TTE. PLS and PCS in each layer of the LVM (endocardium, epicardium, and whole-layer myocardium) were calculated for 17 AHA-defined lesions. MRI assessment showed that fibrosis was classified as endocardial, epicardial, or whole-layer (= either or both of these). Regional PLS was smaller in fibrotic endocardial lesions than in non-fibrotic endocardial lesions (P = 0.004). To detect LV endocardial lesions with fibrosis, ROC curves of regional PLS revealed an area under the curve (AUC) of 0.609 and a best cut-off point of 13.5%, with sensitivity of 65.3% and specificity of 54.3%. Regional PLS was also smaller in fibrotic epicardial lesions than in non-fibrotic epicardial lesions (P layer myocardium analysis, PLS was smaller in fibrotic lesions than in non-fibrotic lesions (P layer LV lesions with fibrosis, ROC curves of regional PLS revealed an AUC of 0.674 and a best cut-off point of 12.5%, with sensitivity of 79.0% and specificity of 50.7%. There were no significant differences in PCS of LV myocardium (endocardium, epicardium, and whole-layer) between fibrotic and non-fibrotic lesions. Quantitative regional PLS but not PCS in LV endocardium, epicardium, and whole-layer myocardium provides useful non-invasive information for layer-specific localization of fibrosis in HCM patients.

  1. Recent evaluations of crack-opening-area in circumferentially cracked pipes

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, S.; Brust, F.; Ghadiali, N.; Wilkowski, G.; Miura, N.

    1997-04-01

    Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. The leak rates depend on the crack-opening area of the through-wall crack in the pipe. In addition to LBB analyses which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessing temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section XI. The objectives of this study were to review, evaluate, and refine current predictive models for performing crack-opening-area analyses of circumferentially cracked pipes. The results from twenty-five full-scale pipe fracture experiments, conducted in the Degraded Piping Program, the International Piping Integrity Research Group Program, and the Short Cracks in Piping and Piping Welds Program, were used to verify the analytical models. Standard statistical analyses were performed to assess used to verify the analytical models. Standard statistical analyses were performed to assess quantitatively the accuracy of the predictive models. The evaluation also involved finite element analyses for determining the crack-opening profile often needed to perform leak-rate calculations.

  2. Numerical analysis of flow in a centrifugal compressor with circumferential grooves: influence of groove location and number on flow instability

    Science.gov (United States)

    Chen, X.; Qin, G.; Ai, Z.; Ji, Y.

    2017-08-01

    As an effective and economic method for flow range enhancement, circumferential groove casing treatment (CGCT) is widely used to increase the stall margin of compressors. Different from traditional grooved casing treatments, in which the grooves are always located over the rotor in both axial and radial compressors, one or several circumferential grooves are located along the shroud side of the diffuser passage in this paper. Numerical investigations were conducted to predict the performance of a low flow rate centrifugal compressor with CGCT in diffuser. Computational fluid dynamics (CFD) analysis is performed under stage environment in order to find the optimum location of the circumferential casing groove in consideration of stall margin enhancement and efficiency gain at design point, and the impact of groove number to the effect of this grooved casing treatment configuration in enhancing the stall margin of the compressor stage is studied. The results indicate that the centrifugal compressor with circumferential groove in vaned diffuser can obtain obvious improvement in the stall margin with sacrificing design efficiency a little. Efforts were made to study blade level flow mechanisms to determine how the CGCT impacts the compressor’s stall margin (SM) and performance. The flow structures in the passage, the tip gap, and the grooves as well as their mutual interactions were plotted and analysed.

  3. Standard practice for estimating the approximate residual circumferential stress in straight thin-walled tubing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 A qualitative estimate of the residual circumferential stress in thin-walled tubing may be calculated from the change in outside diameter that occurs upon splitting a length of the tubing. This practice assumes a linear stress distribution through the tube wall thickness and will not provide an estimate of local stress distributions such as surface stresses. (Very high local residual stress gradients are common at the surface of metal tubing due to cold drawing, peening, grinding, etc.) The Hatfield and Thirkell formula, as later modified by Sachs and Espey, provides a simple method for calculating the approximate circumferential stress from the change in diameter of straight, thin-walled, metal tubing. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Circumferential Stent Fracture: Novel Detection and Treatment with the Use of StentBoost

    OpenAIRE

    Ramegowda, Raghu T.; Chikkaswamy, Srinivas B.; Bharatha, Ashalatha; Radhakrishna, Jayashree; Krishnanaik, Geetha B.; Nanjappa, Manjunath C.; Panneerselvam, Arunkumar

    2012-01-01

    Circumferential stent fracture is extremely uncommon, and in rare cases, it can cause stent thrombosis. Recognizing stent fracture can be difficult on conventional fluoroscopy because of poor stent radiopacity. We found that StentBoost image acquisition yields improved visibility of stent struts, enabling the identification of stent fracture and the precise positioning of new stents over previously stented segments.

  5. Prognostic Value of the Circumferential Resection Margin in Esophageal Cancer Patients After Neoadjuvant Chemoradiotherapy

    NARCIS (Netherlands)

    Hulshoff, J. B.; Faiz, Z.; Karrenbeld, A.; Kats-Ugurlu, G.; Burgerhof, J. G. M.; Smit, J. K.; Plukker, J. Th. M.

    2015-01-01

    Background. Circumferential resection margins (CRM) for esophageal cancer (EC), defined by the College of American Pathologists (CAP; >0 mm) or the Royal College of Pathologists (RCP; >1 mm) as tumor-free (R0), are based on a surgery-alone approach. We evaluated the usefulness of both definitions in

  6. Measurements of the Exerted Pressure by Pelvic Circumferential Compression Devices

    Science.gov (United States)

    Knops, Simon P; van Riel, Marcel P.J.M; Goossens, Richard H.M; van Lieshout, Esther M.M; Patka, Peter; Schipper, Inger B

    2010-01-01

    Background: Data on the efficacy and safety of non-invasive Pelvic Circumferential Compression Devices (PCCDs) is limited. Tissue damage may occur if a continuous pressure on the skin exceeding 9.3 kPa is sustained for more than two or three hours. The aim of this study was to gain insight into the pressure build-up at the interface, by measuring the PCCD-induced pressure when applying pulling forces to three different PCCDs (Pelvic Binder® , SAM-Sling ® and T-POD® ) in a simplified model. Methods: The resulting exerted pressures were measured at four ‘anatomical’ locations (right, left, posterior and anterior) in a model using a pressure measurement system consisting of pressure cuffs. Results: The exerted pressure varied substantially between the locations as well as between the PCCDs. Maximum pressures ranged from 18.9-23.3 kPa and from 19.2-27.5 kPa at the right location and left location, respectively. Pressures at the posterior location stayed below 18 kPa. At the anterior location pressures varied markedly between the different PCCDs. Conclusion: The circumferential compression by the different PCCDs showed high pressures measured at the four locations using a simplified model. Difference in design and functional characteristics of the PCCDs resulted in different pressure build-up at the four locations. When following the manufacturer’s instructions, the exerted pressure of all three PCCDs tested exceeded the tissue damaging level (9.3 kPa). In case of prolonged use in a clinical situation this might put patients at risk for developing tissue damage. PMID:20361001

  7. Reduced Circumferential Resection Margin Involvement in Rectal Cancer Surgery: Results of the Dutch Surgical Colorectal Audit

    NARCIS (Netherlands)

    Gietelink, Lieke; Wouters, Michel W. J. M.; Tanis, Pieter J.; Deken, Marion M.; ten Berge, Martijn G.; Tollenaar, Rob A. E. M.; van Krieken, J. Han; de Noo, Mirre E.

    2015-01-01

    Background: The circumferential resection margin (CRM) is a significant prognostic factor for local recurrence, distant metastasis, and survival after rectal cancer surgery. Therefore, availability of this parameter is essential. Although the Dutch total mesorectal excision trial raised awareness

  8. Reduced Circumferential Resection Margin Involvement in Rectal Cancer Surgery: Results of the Dutch Surgical Colorectal Audit

    NARCIS (Netherlands)

    Gietelink, L.; Wouters, M.W.; Tanis, P.J.; Deken, M.M.; Berge, M.G. Ten; Tollenaar, R.A.; Krieken, J.H.J.M. van; Noo, M.E. de

    2015-01-01

    BACKGROUND: The circumferential resection margin (CRM) is a significant prognostic factor for local recurrence, distant metastasis, and survival after rectal cancer surgery. Therefore, availability of this parameter is essential. Although the Dutch total mesorectal excision trial raised awareness

  9. Fracture behavior of circumferentially surface-cracked elbows. Technical report, October 1993--March 1996

    International Nuclear Information System (INIS)

    Kilinski, T.; Mohan, R.; Rudland, D.; Fleming, M.

    1996-12-01

    This report presents the results from Task 2 of the Second International Piping Integrity Research Group (IPIRG-2) program. The focus of the Task 2 work was directed towards furthering the understanding of the fracture behavior of long-radius elbows. This was accomplished through a combined analytical and experimental program. J-estimation schemes were developed for both axial and circumferential surface cracks in elbows. Large-scale, quasi-static and dynamic, pipe-system, elbow fracture experiments under combined pressure and bending loads were performed on elbows containing an internal surface crack at the extrados. In conjunction with the elbow experiments, material property data were developed for the A106-90 carbon steel and WP304L stainless steel elbow materials investigated. A comparison of the experimental data with the maximum stress predictions using existing straight pipe fracture prediction analysis methods, and elbow fracture prediction methods developed in this program was performed. This analysis was directed at addressing the concerns regarding the validity of using analysis predictions developed for straight pipe to predict the fracture stresses of cracked elbows. Finally, a simplified fitting flaw acceptance criteria incorporating ASME B2 stress indices and straight pipe, circumferential-crack analysis was developed

  10. Estimation of leak rate through circumferential cracks in pipes in nuclear power plants

    Directory of Open Access Journals (Sweden)

    Jai Hak Park

    2015-04-01

    Full Text Available The leak before break (LBB concept is widely used in designing pipe lines in nuclear power plants. According to the concept, the amount of leaking liquid from a pipe should be more than the minimum detectable leak rate of a leak detection system before catastrophic failure occurs. Therefore, accurate estimation of the leak rate is important to evaluate the validity of the LBB concept in pipe line design. In this paper, a program was developed to estimate the leak rate through circumferential cracks in pipes in nuclear power plants using the Henry–Fauske flow model and modified Henry–Fauske flow model. By using the developed program, the leak rate was calculated for a circumferential crack in a sample pipe, and the effect of the flow model on the leak rate was examined. Treating the crack morphology parameters as random variables, the statistical behavior of the leak rate was also examined. As a result, it was found that the crack morphology parameters have a strong effect on the leak rate and the statistical behavior of the leak rate can be simulated using normally distributed crack morphology parameters.

  11. Fracture behavior of circumferentially surface-cracked elbows. Technical report, October 1993--March 1996

    Energy Technology Data Exchange (ETDEWEB)

    Kilinski, T.; Mohan, R.; Rudland, D.; Fleming, M. [and others

    1996-12-01

    This report presents the results from Task 2 of the Second International Piping Integrity Research Group (IPIRG-2) program. The focus of the Task 2 work was directed towards furthering the understanding of the fracture behavior of long-radius elbows. This was accomplished through a combined analytical and experimental program. J-estimation schemes were developed for both axial and circumferential surface cracks in elbows. Large-scale, quasi-static and dynamic, pipe-system, elbow fracture experiments under combined pressure and bending loads were performed on elbows containing an internal surface crack at the extrados. In conjunction with the elbow experiments, material property data were developed for the A106-90 carbon steel and WP304L stainless steel elbow materials investigated. A comparison of the experimental data with the maximum stress predictions using existing straight pipe fracture prediction analysis methods, and elbow fracture prediction methods developed in this program was performed. This analysis was directed at addressing the concerns regarding the validity of using analysis predictions developed for straight pipe to predict the fracture stresses of cracked elbows. Finally, a simplified fitting flaw acceptance criteria incorporating ASME B2 stress indices and straight pipe, circumferential-crack analysis was developed.

  12. Interaction of thermal stress with mechanical stress in circumferentially cracked pipe

    International Nuclear Information System (INIS)

    Song, Tae Kwang; Kim, Yun Jae; Oh, Chang Kyun

    2008-01-01

    For the cracked component under combined primary and secondary stress, an interacion between the loads occurs and the secondary stress is relaxed by the primary load. To account for this phenomena, R6 code provides the correction factor which is called V-factor. However, evaluation corrected with V-factor need to be examined for its conservatism. In this paper the conservatism of the current V-factor is examined for the circumferentially cracked pipe under the combined load and new evaluation method is proposed to reduce the conservatism

  13. Robust assessment of the transmural extent of myocardial infarction in late gadolinium-enhanced MRI studies using appropriate angular and circumferential subdivision of the myocardium

    International Nuclear Information System (INIS)

    Kachenoura, Nadjia; Herment, Alain; Frouin, Frederique; Redheuil, Alban; Mousseaux, Elie

    2008-01-01

    A computer-assisted method is proposed to estimate transmural extent of myocardial infarction. In 40 patients with chronic myocardial infarction and 3 control subjects, late gadolinium enhancement images were acquired with magnetic resonance imaging. Segmental infarct transmural extent was visually assessed by two experts on a 5-point scale. A fuzzy c-means algorithm was applied on both the cavity and myocardium to estimate an enhancement index for 12 sub-regions of each segment. A threshold was defined on a training database (n=29) to establish the transmurality extent of each sub-segment and was applied to the validation database (n=14). Inter-observer reproducibility reached an absolute agreement (Aa) of 85% and a kappa value (κ) of 0.83 when considering the whole training database; Aa decreased to 62% and κ to 0.68 when excluding homogeneous segments. On the validation database, segments were subdivided into three angular sub-segments. Then, inter-observer visual reproducibility reached Aa of 93% and κ of 0.92. Moreover, the absolute comparison of each expert with the computer-assisted method yielded Aa higher than 88% and κ higher than 0.86. The computer-assisted method quantifies infarct transmurality without defining remote and infarcted regions, and the transmural extent is accurately characterized when dividing each segment into three angular sub-segments. (orig.)

  14. Elastic-plastic finite element analyses for reducers with constant-depth internal circumferential surface cracks

    International Nuclear Information System (INIS)

    Wu, Szu-Ying; Tsai, Bor-Jiun; Chen, Jien-Jong

    2015-01-01

    In this study, a 3-D automatic elastic-plastic finite element mesh generator is established to accurately predict the J-integral value of an arbitrary reducer with a constant-depth internal circumferential surface crack under bending and axial force. The contact pairs are used on the crack surfaces to simulate the actual contact behaviors of the crack model under loadings. In order to verify the accuracy of the proposed elastic-plastic finite element model for a reducer with a surface crack, the cracked straight pipe models are generated according to a special modeling procedure for a flawed reducer. The J-integral values along the crack front of surface crack are calculated and compared with the straight pipe models which have been verified in the previous published studies. Based on the comparison of computed results, good agreements are obtained to show the accuracy of present numerical models. More confidence on using the 3-D elastic-plastic finite element analysis for reducers with internal circumferential surface cracks can be thus established in this work

  15. Prediction of leakage and rotordynamic coefficients for the circumferential-groove pump seal using CFD analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Ho; Ha, Tae Woong [Gachon University, Seongnam (Korea, Republic of)

    2016-05-15

    The circumferential-groove seal is commonly used in various turbopumps to reduce leakage. The main goal of this paper is to develop the method of three-dimensional CFD analysis for determining leakage and rotordynamic coefficients of the circumferential-groovepump seal. A relative coordinate system was defined for steady-state simulation to calculate the velocity and pressure distributions of the seal clearance at each rotor whirl speed. Instead of setting the inlet and outlet pressures as the boundary conditions in the three dimensional CFD analysis, as it is more commonly done, we used the inlet velocity and outlet pressure obtained from a preliminary two dimensional CFD analysis. For prediction leakage, the presented analysis shows improvement from the bulk-flow model analysis. For the prediction of rotordynamic coefficients of K, k and C, the presented analysis provides results in closer agreement with the experimental values than those of the bulk-flow model analysis at several rotor speeds.

  16. Strain dyssynchrony index determined by three-dimensional speckle area tracking can predict response to cardiac resynchronization therapy

    Directory of Open Access Journals (Sweden)

    Onishi Tetsuari

    2011-04-01

    Full Text Available Abstract Background We have previously reported strain dyssynchrony index assessed by two-dimensional speckle tracking strain, and a marker of both dyssynchrony and residual myocardial contractility, can predict response to cardiac resynchronization therapy (CRT. A newly developed three-dimensional (3-D speckle tracking system can quantify endocardial area change ratio (area strain, which coupled with the factors of both longitudinal and circumferential strain, from all 16 standard left ventricular (LV segments using complete 3-D pyramidal datasets. Our objective was to test the hypothesis that strain dyssynchrony index using area tracking (ASDI can quantify dyssynchrony and predict response to CRT. Methods We studied 14 heart failure patients with ejection fraction of 27 ± 7% (all≤35% and QRS duration of 172 ± 30 ms (all≥120 ms who underwent CRT. Echocardiography was performed before and 6-month after CRT. ASDI was calculated as the average difference between peak and end-systolic area strain of LV endocardium obtained from 3-D speckle tracking imaging using 16 segments. Conventional dyssynchrony measures were assessed by interventricular mechanical delay, Yu Index, and two-dimensional radial dyssynchrony by speckle-tracking strain. Response was defined as a ≥15% decrease in LV end-systolic volume 6-month after CRT. Results ASDI ≥ 3.8% was the best predictor of response to CRT with a sensitivity of 78%, specificity of 100% and area under the curve (AUC of 0.93 (p Conclusions ASDI can predict responders and LV reverse remodeling following CRT. This novel index using the 3-D speckle tracking system, which shows circumferential and longitudinal LV dyssynchrony and residual endocardial contractility, may thus have clinical significance for CRT patients.

  17. K{sub I}-T estimation for embedded flaws in pipes - Part II: Circumferentially oriented cracks

    Energy Technology Data Exchange (ETDEWEB)

    Qian Xudong, E-mail: cveqx@nus.edu.s [Department of Civil Engineering, National University of Singapore, 1 Engineering Drive 2, Singapore 117576 (Singapore)

    2010-04-15

    This paper, in parallel to the investigation on axially embedded cracks reported in the companion paper, presents a numerical study on the linear-elastic K{sub I} and T-stress values over the front of elliptical cracks circumferentially embedded in the wall of a pipe/cylindrical structure, under a uniform pressure applied on the inner surface of the pipe. The numerical procedure employs the interaction-integral approach to compute the linear-elastic stress-intensity factor (SIF) K{sub I} and T-stress values for embedded cracks with practical sizes at different locations in the wall of the pipe. The parametric study covers a wide range of geometric parameters for embedded cracks in the pipe, including: the wall thickness to the inner radius ratio (t/R{sub i}), the crack depth over the wall thickness ratio (a/t), the crack aspect ratio (a/c) and the ratio of the distance from the centerline of the crack to the outer surface of the pipe over the pipe wall thickness (e{sub M}/t). The parametric investigation identifies a significant effect of the remaining ligament length on both the T-stress and K{sub I} values at the crack-front location (denoted by point O) nearest to the outer surface of the pipe and at the crack-front location (denoted by point I) nearest to the inner surface of the pipe. The numerical investigation establishes the database to derive approximate functions from a nonlinear curve-fitting procedure to predict the T-stress and K{sub I} values at three critical front locations of the circumferentially embedded crack in a pipe: points O, I and M. The proposed T-stress and K{sub I} functions utilize a combined second-order polynomial and a power-law expression, which presents a close agreement with the T-stress and K{sub I} values computed from the very detailed finite element models. The comparison between the circumferentially embedded crack and the axially embedded crack indicates that both the T-stress and K{sub I} values at crack-front points O and

  18. Failure Assessment for the High-Strength Pipelines with Constant-Depth Circumferential Surface Cracks

    OpenAIRE

    X. Liu; Z. X. Lu; Y. Chen; Y. L. Sui; L. H. Dai

    2018-01-01

    In the oil and gas transportation system over long distance, application of high-strength pipeline steels can efficiently reduce construction and operation cost by increasing operational pressure and reducing the pipe wall thickness. Failure assessment is an important issue in the design, construction, and maintenance of the pipelines. The small circumferential surface cracks with constant depth in the welded pipelines are of practical interest. This work provides an engineering estimation pr...

  19. The May 2005 eruption of Fernandina volcano, Galápagos: The first circumferential dike intrusion observed by GPS and InSAR

    Science.gov (United States)

    Chadwick, W.W.; Jonsson, Sigurjon; Geist, Dennis J.; Poland, M.; Johnson, Daniel J.; Batt, S.; Harpp, Karen S.; Ruiz, A.

    2011-01-01

    The May 2005 eruption of Fernandina volcano, Galápagos, occurred along circumferential fissures parallel to the caldera rim and fed lava flows down the steep southwestern slope of the volcano for several weeks. This was the first circumferential dike intrusion ever observed by both InSAR and GPS measurements and thus provides an opportunity to determine the subsurface geometry of these enigmatic structures that are common on Galápagos volcanoes but are rare elsewhere. Pre- and post- eruption ground deformation between 2002 and 2006 can be modeled by the inflation of two separate magma reservoirs beneath the caldera: a shallow sill at ~1 km depth and a deeper point-source at ~5 km depth, and we infer that this system also existed at the time of the 2005 eruption. The co-eruption deformation is dominated by uplift near the 2005 eruptive fissures, superimposed on a broad subsidence centered on the caldera. Modeling of the co-eruption deformation was performed by including various combinations of planar dislocations to simulate the 2005 circumferential dike intrusion. We found that a single planar dike could not match both the InSAR and GPS data. Our best-fit model includes three planar dikes connected along hinge lines to simulate a curved concave shell that is steeply dipping (~45–60°) toward the caldera at the surface and more gently dipping (~12–14°) at depth where it connects to the horizontal sub-caldera sill. The shallow sill is underlain by the deep point source. The geometry of this modeled magmatic system is consistent with the petrology of Fernandina lavas, which suggest that circumferential eruptions tap the shallowest parts of the system, whereas radial eruptions are fed from deeper levels. The recent history of eruptions at Fernandina is also consistent with the idea that circumferential and radial intrusions are sometimes in a stress-feedback relationship and alternate in time with one another.

  20. The May 2005 eruption of Fernandina volcano, Galápagos: The first circumferential dike intrusion observed by GPS and InSAR

    KAUST Repository

    Chadwick, William W Jr; Jonsson, Sigurjon; Geist, Dennis J.; Poland, Michael P.; Johnson, Daniel J.; Batt, Spencer; Harpp, Karen S.; Ruiz, André s Gorki

    2010-01-01

    The May 2005 eruption of Fernandina volcano, Galápagos, occurred along circumferential fissures parallel to the caldera rim and fed lava flows down the steep southwestern slope of the volcano for several weeks. This was the first circumferential dike intrusion ever observed by both InSAR and GPS measurements and thus provides an opportunity to determine the subsurface geometry of these enigmatic structures that are common on Galápagos volcanoes but are rare elsewhere. Pre- and post- eruption ground deformation between 2002 and 2006 can be modeled by the inflation of two separate magma reservoirs beneath the caldera: a shallow sill at ~1 km depth and a deeper point-source at ~5 km depth, and we infer that this system also existed at the time of the 2005 eruption. The co-eruption deformation is dominated by uplift near the 2005 eruptive fissures, superimposed on a broad subsidence centered on the caldera. Modeling of the co-eruption deformation was performed by including various combinations of planar dislocations to simulate the 2005 circumferential dike intrusion. We found that a single planar dike could not match both the InSAR and GPS data. Our best-fit model includes three planar dikes connected along hinge lines to simulate a curved concave shell that is steeply dipping (~45-60°) toward the caldera at the surface and more gently dipping (~12-14°) at depth where it connects to the horizontal sub-caldera sill. The shallow sill is underlain by the deep point source. The geometry of this modeled magmatic system is consistent with the petrology of Fernandina lavas, which suggest that circumferential eruptions tap the shallowest parts of the system, whereas radial eruptions are fed from deeper levels. The recent history of eruptions at Fernandina is also consistent with the idea that circumferential and radial intrusions are sometimes in a stress-feedback relationship and alternate in time with one another. © 2010 Springer-Verlag.

  1. The May 2005 eruption of Fernandina volcano, Galápagos: The first circumferential dike intrusion observed by GPS and InSAR

    KAUST Repository

    Chadwick, William W Jr

    2010-12-15

    The May 2005 eruption of Fernandina volcano, Galápagos, occurred along circumferential fissures parallel to the caldera rim and fed lava flows down the steep southwestern slope of the volcano for several weeks. This was the first circumferential dike intrusion ever observed by both InSAR and GPS measurements and thus provides an opportunity to determine the subsurface geometry of these enigmatic structures that are common on Galápagos volcanoes but are rare elsewhere. Pre- and post- eruption ground deformation between 2002 and 2006 can be modeled by the inflation of two separate magma reservoirs beneath the caldera: a shallow sill at ~1 km depth and a deeper point-source at ~5 km depth, and we infer that this system also existed at the time of the 2005 eruption. The co-eruption deformation is dominated by uplift near the 2005 eruptive fissures, superimposed on a broad subsidence centered on the caldera. Modeling of the co-eruption deformation was performed by including various combinations of planar dislocations to simulate the 2005 circumferential dike intrusion. We found that a single planar dike could not match both the InSAR and GPS data. Our best-fit model includes three planar dikes connected along hinge lines to simulate a curved concave shell that is steeply dipping (~45-60°) toward the caldera at the surface and more gently dipping (~12-14°) at depth where it connects to the horizontal sub-caldera sill. The shallow sill is underlain by the deep point source. The geometry of this modeled magmatic system is consistent with the petrology of Fernandina lavas, which suggest that circumferential eruptions tap the shallowest parts of the system, whereas radial eruptions are fed from deeper levels. The recent history of eruptions at Fernandina is also consistent with the idea that circumferential and radial intrusions are sometimes in a stress-feedback relationship and alternate in time with one another. © 2010 Springer-Verlag.

  2. Single stage circumferential lingual mucosal graft urethroplasty in near obliterative bulbar urethra stricture: A novel technique

    Directory of Open Access Journals (Sweden)

    Umesh Sharma

    2016-01-01

    Full Text Available Aims: This is a prospective study of the use and efficacy of a novel technique of circumferential tubularised lingual mucosal graft (LMG in obliterative and near obliterative bulbar urethral stricture of >2 cm where excisional and augmented anastomotic urethroplasty are not feasible. Materials and Methods: The stenotic urethral segment was opened dorsally in midline and fibrosed urethra was excised taking care to preserve the healthy spongiosum tissue. LMG (av. Length 3 cm was placed from one end of corporal body towards spongy tissue in a circumferential manner. Another LMG was placed in similar manner to deal with longer stricture. The urethra was tubularised over 14 Fr silicone catheter. Results: A total of 12 men, of mean age 47 years underwent this procedure. The mean follow up period was 11 months starting from July 2014 till manuscript submission. Follow up included voiding cystourethrogram at 3 weeks, cystoscopy at 3 months (one patient didn't turned up and subsequent follow up. Mean stricture length was 4.66 cm (range, 3–8.5 cm and mean operative time was 195 min. (range, 160 to 200 min.. The technique was successful (normal voiding with no need for any post-operative procedure in 11(91.6% patients. One patient developed early recurrence at 4 month of surgery and had anastomotic stricture which was successfully managed by direct visual internal urethrotomy. Conclusion: Single stage circumferential tubularised graft urethroplasty is an excellent technique for strictures that include segments of obliterative and near obliterative diseased urethra. It provide a wider neourethra than patch graft urethroplasty.

  3. Single stage circumferential lingual mucosal graft urethroplasty in near obliterative bulbar urethra stricture: A novel technique.

    Science.gov (United States)

    Sharma, Umesh; Yadav, Sher Singh; Tomar, Vinay; Garg, Amit

    2016-01-01

    This is a prospective study of the use and efficacy of a novel technique of circumferential tubularised lingual mucosal graft (LMG) in obliterative and near obliterative bulbar urethral stricture of >2 cm where excisional and augmented anastomotic urethroplasty are not feasible. The stenotic urethral segment was opened dorsally in midline and fibrosed urethra was excised taking care to preserve the healthy spongiosum tissue. LMG (av. Length 3 cm) was placed from one end of corporal body towards spongy tissue in a circumferential manner. Another LMG was placed in similar manner to deal with longer stricture. The urethra was tubularised over 14 Fr silicone catheter. A total of 12 men, of mean age 47 years underwent this procedure. The mean follow up period was 11 months starting from July 2014 till manuscript submission. Follow up included voiding cystourethrogram at 3 weeks, cystoscopy at 3 months (one patient didn't turned up) and subsequent follow up. Mean stricture length was 4.66 cm (range, 3-8.5 cm) and mean operative time was 195 min. (range, 160 to 200 min.). The technique was successful (normal voiding with no need for any post-operative procedure) in 11(91.6%) patients. One patient developed early recurrence at 4 month of surgery and had anastomotic stricture which was successfully managed by direct visual internal urethrotomy. Single stage circumferential tubularised graft urethroplasty is an excellent technique for strictures that include segments of obliterative and near obliterative diseased urethra. It provide a wider neourethra than patch graft urethroplasty.

  4. Instrumented circumferential fusion for tuberculosis of the dorso-lumbar spine. A single or double stage procedure?

    Science.gov (United States)

    El-Sharkawi, Mohammad Mostafa; Said, Galal Zaki

    2012-02-01

    The purpose of this study was to present our experience in treating dorso-lumbar tuberculosis by one-stage posterior circumferential fusion and to compare this group with a historical group treated by anterior debridement followed by postero-lateral fusion and stabilization. Between 2003 and 2008, 32 patients with active spinal tuberculosis were treated by one-stage posterior circumferential fusion and prospectively followed for a minimum of two years. Pain severity was measured using Visual Analogue Scale (VAS). Neurological assessment was done using the Frankel scale. The operative data, clinical, radiological, and functional outcomes were also compared to a similar group of 25 patients treated with anterior debridement and fusion, followed 10-14 days later by posterior stabilization and postero-lateral fusion. The mean operative time and duration of hospital stay were significantly longer in the two-stage group. The mean estimated blood loss was also larger, though insignificantly, in the two-stage group. The incidence of complications was significantly lower in the one-stage group. At final follow-up, all 34 patients with pre-operative neurological deficits showed at least one Frankel grade of neurological improvement, all 57 patients showed significant improvement of their VAS back pain score, the mean kyphotic angle has significantly improved, all patients achieved solid fusion and 43 (75.4%) patients returned to their pre-disease activity level or work. Instrumented circumferential fusion, whether in one or two stages, is an effective treatment for dorso-lumbar tuberculosis. One-stage surgery, however, is advantageous because it has lower complication rate, shorter hospital stay, less operative time and blood loss.

  5. A study of the effect of circumferential temperature variations on fuel-sheath strain in an inert atmosphere

    International Nuclear Information System (INIS)

    Ferner, J.; Rondeau, R.K.; Rosinger, H.E.

    1983-07-01

    A failure model for Zircaloy-4 fuel sheaths has been developed and used to predict the effect of circumferential temperature variations (ΔT) on fuel-sheath strain behaviour in an inert atmosphere. In addition, experimental data were generated for fuel-sheath failures in the α and (α+β)-phase regions and compared to the predictions of the model. For both the experimental data and the model predictions it was found that increasing ΔT decreases sheath strain. Most of the reduction in burst strain with increasing ΔT occurs in the first 15 K to 20 K. For high ΔT values, burst strains in the α- and (α+β)-phase regions tend to an asymptotic value in the range 5 to 20 percent, irrespective of both heating rate and circumferential temperature variation. The BURST-2 computer code was used for these calculations

  6. Circumferential resection margin (CRM) positivity after MRI assessment and adjuvant treatment in 189 patients undergoing rectal cancer resection.

    Science.gov (United States)

    Simpson, G S; Eardley, N; McNicol, F; Healey, P; Hughes, M; Rooney, P S

    2014-05-01

    The management of rectal cancer relies on accurate MRI staging. Multi-modal treatments can downstage rectal cancer prior to surgery and may have an effect on MRI accuracy. We aim to correlate the findings of MRI staging of rectal cancer with histological analysis, the effect of neoadjuvant therapy on this and the implications of circumferential resection margin (CRM) positivity following neoadjuvant therapy. An analysis of histological data and radiological staging of all cases of rectal cancer in a single centre between 2006 and 2011 were conducted. Two hundred forty-one patients had histologically proved rectal cancer during the study period. One hundred eighty-two patients underwent resection. Median age was 66.6 years, and male to female ratio was 13:5. R1 resection rate was 11.1%. MRI assessments of the circumferential resection margin in patients without neoadjuvant radiotherapy were 93.6 and 88.1% in patients who underwent neoadjuvant radiotherapy. Eighteen patients had predicted positive margins following chemoradiotherapy, of which 38.9% had an involved CRM on histological analysis. MRI assessment of the circumferential resection margin in rectal cancer is associated with high accuracy. Neoadjuvant chemoradiotherapy has a detrimental effect on this accuracy, although accuracy remains high. In the presence of persistently predicted positive margins, complete resection remains achievable but may necessitate a more radical approach to resection.

  7. Analysis on Propagation Characteristics and Experimental Verification of A1 Circumferential Waves in Nuclear Fuel Rods Coated with Oxide Layers

    International Nuclear Information System (INIS)

    Joo, Young Sang; Jung, Hyun Kyu; Cheong, Yong Moo; Ih, Jeong Guon

    1999-01-01

    The resonance scattering of acoustic waves from the cylindrical shells of nuclear fuel rods coated with oxide layers has been theoretically modeled and numerically analyzed for the propagation characteristics of the circumferential waves. The normal mode solutions of the scattering pressure of the coated shells have been obtained. The pure resonance components have been isolated using the newly proposed inherent background coefficients. The propagation characteristics of resonant circumferential waves for the shells coated with oxide layers are affected by the presence and the thickness of an oxide layer. The characteristics have been experimentally confirmed through the method of isolation and identification of resonances. The change of the phase velocity of the A 1 circumferential wave mode for the coated shell is negligible at the specified partial waves in spite of the presence of the oxide layer and the increase in coating thickness. Utilizing the invariability characteristics of the phase velocity of the A 1 mode, the oxide layer thickness of the coated shells can be estimated. A new nondestructive technique for the relative measurement of the coating thickness of coated shells has been proposed

  8. An efficient and low resistant circumferential overlap trisection helical baffle heat exchanger with folded baffles

    International Nuclear Information System (INIS)

    Dong, Cong; Li, Dongshuang; Zheng, Youqu; Li, Guoneng; Suo, Yange; Chen, Yaping

    2016-01-01

    Highlights: • The novel cothHXf with circumferential overlap and folded baffles is first proposed. • The key sections of cylindrical and dumbbell are constructed to analyze local flow field characteristics. • The restricted leakage, easier to install and low resistant characteristics are emphasized. • The enhanced heat transfer mechanism of Dean Vortex secondary flow is analyzed. • A variety of comprehensive efficiency assessments are used. - Abstract: An efficient and low resistant circumferential overlap trisection helical baffle shell-and-tube heat exchanger with folded baffles (cothHXf) is presented. It is a modified trisection helical baffle heat exchanger with folded helical baffles for setting rods-and-spanning sleeves. It not only inherits all the merits of circumferential overlap helical baffle scheme, but also adds many additional advantages, such as supporting the inclined baffles with the least rods, simplifying the manufacturing process of spanning tubes and effectively inhibiting the reverse leakage at triangular areas between adjacent baffles. The improved flow characteristic and heat transfer enhancement mechanism of this heat exchanger were numerically investigated in comparison with conventional segmental baffles shell-and-tube heat exchanger (segHX). The flow fields within triangular area of adjacent baffles and nearby regions were depicted. The impacts of the folded baffles on shell-side helical flow, secondary vortex flow, and leakage pattern were analyzed. The distribution configurations of fields of velocity, pressure, temperature and local heat flow rate were revealed. The results show that the heat transfer performance and comprehensive performance evaluation indexes of the cothHXf are much better than those of the segHX while the pressure drop of the cothHXf is much lower than that of the segHX. The numerical simulation results of vivid distributions of flow and thermal fields of the cothHXf can provide theoretical basis for an

  9. Automated assessments of circumferential strain from cine CMR correlate with LVEF declines in cancer patients early after receipt of cardio-toxic chemotherapy.

    Science.gov (United States)

    Jolly, Marie-Pierre; Jordan, Jennifer H; Meléndez, Giselle C; McNeal, Gary R; D'Agostino, Ralph B; Hundley, W Gregory

    2017-08-02

    In patients with cancer receiving potentially cardio-toxic chemotherapy, measurements of left ventricular (LV) circumferential or longitudinal strain are often used clinically to identify myocardial dysfunction. Using a new software algorithm, we sought to determine in individuals receiving treatment for cancer the association between automated assessments of LV mean mid-wall circumferential strain and conventional measures of LV ejection fraction (EF) both obtained from cardiovascular magnetic resonance (CMR) cine balanced steady-state free-precession (bSSFP) white-blood acquisitions. Before and 3 months after initiating treatment with potentially cardio-toxic chemotherapy, 72 individuals (aged 54 ± 14 years with breast cancer [39%], lymphoma [49%], or sarcoma [12%]) underwent serial CMR cine bSSFP assessments of LV volumes and EF, and mean mid-wall circumferential strain determined from these same cine images as well as from additional tagged CMR images. On the cine images, assessments of strain were obtained using the newly developed deformation-based segmentation algorithm. Assessments of LV volumes/EF from the cine images and strain from tagged CMR were accomplished using commercially available software. All measures were analyzed in a blinded fashion independent of one another. Acceptable measures for the automated assessments of mean mid-wall circumferential strain from the cine images were obtained in 142 of 144 visits (98.6%) with an overall analysis time averaging 6:47 ± 1:06 min. The results from these automated measures averaged -18.8 ± 2.9 at baseline and -17.6 ± 3.1 at 3 months (p = 0.001). Left ventricular EF declined slightly from 65 ± 7% at baseline to 62 ± 7% at 3 months (p = 0.0002). The correlation between strain from cine imaging and LVEF was r = -0.61 (p cine and tagged derived assessments of strain was r = 0.23; p = 0.01. Automated measures of LV mean mid-wall circumferential strain can be obtained in 6

  10. Association of left ventricular longitudinal and circumferential systolic dysfunction with diastolic function in hypertension: a nonlinear analysis focused on the interplay with left ventricular geometry.

    Science.gov (United States)

    Ballo, Piercarlo; Nistri, Stefano; Cameli, Matteo; Papesso, Barbara; Dini, Frank Lloyd; Galderisi, Maurizio; Zuppiroli, Alfredo; Mondillo, Sergio

    2014-02-01

    The relationships of left ventricular (LV) longitudinal and circumferential systolic dysfunction with diastolic performance in hypertensive patients have never been compared. In 532 asymptomatic hypertensive patients, circumferential function was assessed with the use of midwall fractional shortening (mFS) and stress-corrected mFS (SCmFS), whereas longitudinal function was assessed with the use of left atrioventricular plane displacement (AVPD) and systolic mitral annulus velocity (s'). Early diastolic annular velocity (e') and the E/e' ratio were measured. Global longitudinal and circumferential strain were determined in a subset of 210 patients. e' was linearly related to all systolic indexes (AVPD: R = 0.40; s': R = 0.39; mFS: R = 0.16; SCmFS: R = 0.17; all P SCmFS. Longitudinal indexes were superior to circumferential ones in predicting e' <8 cm/s, E/e' <8, and E/e' ≥13. The effect of LV geometry on LV diastolic function was evident among patients with preserved systolic longitudinal function, but was blunted among patients with impaired longitudinal function. In multivariable analyses, only longitudinal indexes remained associated with e' and E/e'. Analyses using strains provided similar results. In asymptomatic hypertensive subjects, LV diastolic performance is independently associated with longitudinal systolic dysfunction, but not with circumferential systolic dysfunction. Subtle longitudinal systolic impairment plays a role in mediating the effect of LV geometry on diastolic performance. These findings may support the need of critically revising the concept of isolated diastolic dysfunction in these patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. The Influence of Hospital Volume on Circumferential Resection Margin Involvement: Results of the Dutch Surgical Colorectal Audit

    NARCIS (Netherlands)

    Gietelink, Lieke; Henneman, Daniel; van Leersum, Nicoline J.; de Noo, Mirre; Manusama, Eric; Tanis, Pieter J.; Tollenaar, Rob A. E. M.; Wouters, Michel W. J. M.

    2016-01-01

    This population-based study evaluates the association between hospital volume and CRM (circumferential resection margin) involvement, adjusted for other confounders, in rectal cancer surgery. A low hospital volume ( <20 cases/year) was independently associated with a higher risk of CRM involvement

  12. Quantitative lymphoscintigraphy in post-mastectomy lymphedema: correlation with circumferential measurements

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Joon Young; Lee, Kyung Han; Kim, Sang Eun; Kim, Byung Tae; Hwang, Jee Hea; Lee, Byung Boong [Samsung Medical Center, Seoul (Korea, Republic of)

    1997-07-01

    An objective measure for the severity and progression is important for the management of lymphedema. To evaluate the usefulness of lympho-scintigraphy in this regard, we compared various quantitative indices from upper extremity lymphoscintigraphy with circumferential measurements, before and after physiotheraphy. Upper extremity lymphoscintigraphy was performed in 38 patients with unilateral postmastectomy lymphedema. Tc-99m antimony sulfide colloid (37 MBq) was injected s.c. into the second and third interdigital spaces. The injection sites were imaged immediately after injection. After standardized exercise for 15 min, upper extremity images were acquired 30 min, 1 hr and 2 hr after injection. The clearance of the injection site (CL), and % uptake in regional lymph nodes (%LN) and soft tissue of the extremity (i.e., the degree of dermal backflow) (%EXT) compared to the initial injection site were calculated. Circumference of each extremity was measured at 7 levels; the severity of lymphedema was expressed as the percentage difference of total circumferential difference (TCD) between healthy and edematous extremities compared to the total circumference of healthy extremity (%TCD). In 19 patients who received physiotherapy, the therapeutic effect was measured by % decrease of TCD (%DTCD) before and after therapy (Raines. et al., 1977). The quantitative indices calculated in the image at 2 hr p.i. had better correlation with either %TCD or %DTCD than those from earlier images (Table). The CL, %LN and %EXT of edematous extremity had a significant correlation with TCD. The %EXT was correlated best with either TCD or %DTCD. The results suggest that the %EXT which corresponds to the degree of dermal backflow may be a simple and useful quantitative index for evaluating the severity and progression in lymphedema and predicting the effect of therapy.

  13. Quantitative lymphoscintigraphy in post-mastectomy lymphedema: correlation with circumferential measurements

    International Nuclear Information System (INIS)

    Choi, Joon Young; Lee, Kyung Han; Kim, Sang Eun; Kim, Byung Tae; Hwang, Jee Hea; Lee, Byung Boong

    1997-01-01

    An objective measure for the severity and progression is important for the management of lymphedema. To evaluate the usefulness of lympho-scintigraphy in this regard, we compared various quantitative indices from upper extremity lymphoscintigraphy with circumferential measurements, before and after physiotheraphy. Upper extremity lymphoscintigraphy was performed in 38 patients with unilateral postmastectomy lymphedema. Tc-99m antimony sulfide colloid (37 MBq) was injected s.c. into the second and third interdigital spaces. The injection sites were imaged immediately after injection. After standardized exercise for 15 min, upper extremity images were acquired 30 min, 1 hr and 2 hr after injection. The clearance of the injection site (CL), and % uptake in regional lymph nodes (%LN) and soft tissue of the extremity (i.e., the degree of dermal backflow) (%EXT) compared to the initial injection site were calculated. Circumference of each extremity was measured at 7 levels; the severity of lymphedema was expressed as the percentage difference of total circumferential difference (TCD) between healthy and edematous extremities compared to the total circumference of healthy extremity (%TCD). In 19 patients who received physiotherapy, the therapeutic effect was measured by % decrease of TCD (%DTCD) before and after therapy (Raines. et al., 1977). The quantitative indices calculated in the image at 2 hr p.i. had better correlation with either %TCD or %DTCD than those from earlier images (Table). The CL, %LN and %EXT of edematous extremity had a significant correlation with TCD. The %EXT was correlated best with either TCD or %DTCD. The results suggest that the %EXT which corresponds to the degree of dermal backflow may be a simple and useful quantitative index for evaluating the severity and progression in lymphedema and predicting the effect of therapy

  14. The role of infarct transmural extent in infarct extension: A computational study.

    Science.gov (United States)

    Leong, Chin-Neng; Lim, Einly; Andriyana, Andri; Al Abed, Amr; Lovell, Nigel Hamilton; Hayward, Christopher; Hamilton-Craig, Christian; Dokos, Socrates

    2017-02-01

    Infarct extension, a process involving progressive extension of the infarct zone (IZ) into the normally perfused border zone (BZ), leads to continuous degradation of the myocardial function and adverse remodelling. Despite carrying a high risk of mortality, detailed understanding of the mechanisms leading to BZ hypoxia and infarct extension remains unexplored. In the present study, we developed a 3D truncated ellipsoidal left ventricular model incorporating realistic electromechanical properties and fibre orientation to examine the mechanical interaction among the remote, infarct and BZs in the presence of varying infarct transmural extent (TME). Localized highly abnormal systolic fibre stress was observed at the BZ, owing to the simultaneous presence of moderately increased stiffness and fibre strain at this region, caused by the mechanical tethering effect imposed by the overstretched IZ. Our simulations also demonstrated the greatest tethering effect and stress in BZ regions with fibre direction tangential to the BZ-remote zone boundary. This can be explained by the lower stiffness in the cross-fibre direction, which gave rise to a greater stretching of the IZ in this direction. The average fibre strain of the IZ, as well as the maximum stress in the sub-endocardial layer, increased steeply from 10% to 50% infarct TME, and slower thereafter. Based on our stress-strain loop analysis, we found impairment in the myocardial energy efficiency and elevated energy expenditure with increasing infarct TME, which we believe to place the BZ at further risk of hypoxia. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Risk factors of circumferential resection margin involvement in the patients with extraperitoneal rectal cancer.

    Science.gov (United States)

    Oh, Sung Jin; Shin, Jin Yong

    2012-03-01

    Currently, circumferential resection margins (CRM) are used as a clinical endpoint in studies on the prognosis of rectal cancer. Although the concept of a circumferential resection margin in extraperitoneal rectal cancer differs from that in intraperitoneal rectal cancer due to differences in anatomical and biologic behaviors, previous reports have provided information on CRM involvement in all types of rectal cancer including intraperitoneal lesions. Therefore, the aim of this study was to analyze risk factors of CRM involvement in extraperitoneal rectal cancer. From January 2005 to December 2008, 306 patients with extraperitoneal rectal cancer were enrolled in a prospectively collected database. Multivariate logistic regression analysis was used to identify predictors of CRM involvement. The overall rate of CRM involvement was found to be 16.0%. Multivariate analysis showed that male sex, larger tumor size (≥4 cm), stage higher than T3, nodal metastasis, tumor perforation and non-sphincter preserving proctectomy (NSPP) were risk factors for CRM involvement. Male sex, larger tumor size (≥4 cm), advanced T stage, nodal metastasis, tumor perforation, and NSPP are significant risk factors of CRM involvement in extraperitoneal rectal cancer. Given that postoperative chemoradiotherapy is recommended for patients with a positive CRM, further oncologic studies are warranted to ascertain which patients with these risk factors would require adjuvant therapy.

  16. Milligan-Morgan hemorrhoidectomy with anal cushion suspension and partial internal sphincter resection for circumferential mixed hemorrhoids

    Science.gov (United States)

    Lu, Ming; Shi, Guang-Ying; Wang, Guo-Qiang; Wu, Yan; Liu, Yang; Wen, Hao

    2013-01-01

    AIM: To identify a more effective treatment protocol for circumferential mixed hemorrhoids. METHODS: A total of 192 patients with circumferential mixed hemorrhoids were randomized into the treatment group, where they underwent Milligan-Morgan hemorrhoidectomy with anal cushion suspension and partial internal sphincter resection, or the control group, where traditional external dissection and internal ligation were performed. Postoperative recovery and complications were monitored. RESULTS: The time to wound healing was 12.96 ± 2.25 d in the treatment group shorter than 19.58 ± 2.71 d in the control group. Slight pain rate was 58.3% in the treatment group higher than 22.9% in the control group; moderate pain rate was 33.3% in the treatment group lower than 56.3% in the control group severe pain rate was 8.4% in the treatment group lower than 20.8% in the control group. No edema rate was 70.8% in the treatment group higher than 43.8% in the control group; mild local edema rate was 26% in the treatment group lower than 39.6% in the control group obvious local edema was 3.03% in the treatment group lower than 16.7% in the control group. No stenosis rate was 85.4% in the treatment group higher than 63.5% in the control group; moderate stenosis rate was 14.6% in the treatment group Lower than 27.1% in the control group severe anal stenosis rate was 0% in the treatment group lower than 9.4% in the control group. CONCLUSION: Milligan-Morgan hemorrhoidectomy with anal cushion suspension and partial internal sphincter resection is the optimal treatment for circumferential mixed hemorrhoids and can be widely applied in clinical settings. PMID:23946609

  17. Development of K and COD Solutions of Non-idealized Circumferential Through-wall Cracks for PARTRIDGE

    International Nuclear Information System (INIS)

    Park, Jeong Soon; Kim, Sun Hye; Kim, Jin Su and others

    2013-01-01

    PARTRIDGE (Probabilistic Analysis as a Regulatory Tool for Risk Informed Decision GuidancE) is an international research program, main purposes of which are to enhance PRO-LOCA (PRObabilistic-Loss Of Coolant Accident) code, a research piping probabilistic fracture mechanics code originally developed for USNRC, and to support the development of a new modular probabilistic fracture mechanics code, xLPR(Extremely Low Probability of Rupture). KINS, KHNP, and KEPCO E and C established a Korea Consortium to take part in the PARTRIDGE and have provided not only financial but also technical contribution to it. As part of the research in-kind contribution, Korea Consortium has developed new Mode I stress intensity factors (KI) and crack opening displacements (COD, δ) for non-idealized through-wall cracks along with EMC2 (Engineering Mechanics Corporation of Columbus). In this paper, the results of linear elastic fracture mechanics (LEFM) analysis for non-idealized circumferential through-wall cracks performed by Korea Consortium were provided. Korea Consortium, KINS, KHNP, and KEPCO E and C, performs LEFM analyses for non-idealized circumferential through-wall cracks as part of in-kind contribution to the international research program called PARTRIDGE

  18. Influence of circumferential notch and fatigue crack on the mechanical integrity of biodegradable magnesium-based alloy in simulated body fluid.

    Science.gov (United States)

    Bobby Kannan, M; Singh Raman, R K; Witte, F; Blawert, C; Dietzel, W

    2011-02-01

    Applications of magnesium alloys as biodegradable orthopaedic implants are critically dependent on the mechanical integrity of the implant during service. In this study, the mechanical integrity of an AZ91 magnesium alloy was studied using a constant extension rate tensile (CERT) method. The samples in two different geometries that is, circumferentially notched (CN), and circumferentially notched and fatigue cracked (CNFC), were tested in air and in simulated body fluid (SBF). The test results show that the mechanical integrity of the AZ91 magnesium alloy decreased substantially (∼50%) in both the CN and CNFC samples exposed to SBF. Fracture surface analysis revealed secondary cracks suggesting stress corrosion cracking susceptibility of the alloy in SBF. Copyright © 2010 Wiley Periodicals, Inc.

  19. Burn-out, Circumferential Film Flow Distribution and Pressure Drop for an Eccentric Annulus with Heated Rod

    DEFF Research Database (Denmark)

    Andersen, P. S.; Jensen, A.; Mannov, G.

    1974-01-01

    Measurements of (1) burn-out, (2) circumferential film flow distribution, and (3) pressure drop in a 17 × 27.2 × 3500 mm concentric and eccentric annulus geometry are presented. The eccentric displacement was varied between 0 and 3 mm. The working fluid was water. Burn-out curves at 70 bar...... flow variation on burn-out is discussed....

  20. Crack shape developments and leak rates for circumferential complex-cracked pipes

    Energy Technology Data Exchange (ETDEWEB)

    Brickstad, B.; Bergman, M. [SAQ Inspection Ltd., Stockholm (Sweden)

    1997-04-01

    A computerized procedure has been developed that predicts the growth of an initial circumferential surface crack through a pipe and further on to failure. The crack growth mechanism can either be fatigue or stress corrosion. Consideration is taken to complex crack shapes and for the through-wall cracks, crack opening areas and leak rates are also calculated. The procedure is based on a large number of three-dimensional finite element calculations of cracked pipes. The results from these calculations are stored in a database from which the PC-program, denoted LBBPIPE, reads all necessary information. In this paper, a sensitivity analysis is presented for cracked pipes subjected to both stress corrosion and vibration fatigue.

  1. Circumferential skin folds in a child: A case of Michelin tire baby syndrome

    Directory of Open Access Journals (Sweden)

    Palit Aparna

    2007-01-01

    Full Text Available A six-month-old girl who presented with dermatitis was found to have multiple, symmetric, deep, gyrate skin folds involving her trunk and similar circumferential lesions on her extremities since birth. She had a characteristic round face with hypertelorism, depressed nasal bridge, thin, down-turned vermillion border of upper lip and short neck. Skin biopsy demonstrated increased smooth muscle fibers in the deeper dermis. A diagnosis of Michelin tire baby syndrome was made. Clinical features, histopathology, differential diagnosis and prognosis of this rare disorder have been discussed.

  2. End-systolic stress-velocity relation and circumferential fiber velocity shortening for analysing left ventricular function in mice

    Energy Technology Data Exchange (ETDEWEB)

    Fayssoil, A. [Cardiologie, Hopital europeen Georges Pompidou, 20, rue le blanc, Paris (France)], E-mail: fayssoil2000@yahoo.fr; Renault, G. [CNRS UMR 8104, Inserm, U567, Institut Cochin, Universite Paris Descartes, Paris (France); Fougerousse, F. [Genethon, RD, Evry (France)

    2009-08-15

    Traditionally, analysing left ventricular (LV) performance relies on echocardiography by evaluating shortening fraction (SF) in mice. SF is influenced by load conditions. End-systolic stress-velocity (ESSV) relation and circumferential fiber velocity (VcF) shortening are more relevant parameters for evaluating systolic function regardless load conditions particularly in mice's models of heart failure.

  3. An approximative solution for limit load of piping branch junctions with circumferential crack and finite element validation

    International Nuclear Information System (INIS)

    Xuan Fuzhen; Liu Changjun; Li Peining

    2005-01-01

    This paper is concerned with the prediction of limit load of the piping branch junctions with circumferential crack under internal pressure. Recently, we have developed a new approach for predicting the limit load of two-cylinder intersection structures with diameter ratio larger than 0.5, which has been successfully applied to defect free cases under various loading conditions. In the present work, we consider the extension of the approach to cover cracked piping branch junctions. On the basis of stress analysis in the vicinity of intersection line, a closed form of limit load solution for piping branch junctions with circumferential crack was developed. Then, 36 finite element (FE) models of piping branch junction with various dimensions of structure and crack were analyzed by using nonlinear finite element software. The limit loads from FE analysis and the proposed solution are compared with each other. Overall good agreement between the estimated solutions and the FE results provides confidence in the use of the proposed formulae for defect assessment of piping branch junctions in practice

  4. Refinement and evaluation of crack-opening-area analyses for circumferential through-wall cracks in pipes

    International Nuclear Information System (INIS)

    Rahman, S.; Brust, F.; Ghadiali, N.; Krishnaswamy, P.; Wilkowski, G.; Choi, Y.H.; Moberg, F.; Brickstad, B.

    1995-04-01

    Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet impingement shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. These leak rates depend on the crack-opening area of a through-wall crack in the pipe. In addition to LBB analyses, which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessing temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section 11. This study was requested by the NRC to review, evaluate, and refine current analytical models for crack-opening-area analyses of pipes with circumferential through-wall cracks. Twenty-five pipe experiments were analyzed to determine the accuracy of the predictive models. Several practical aspects of crack-opening such as; crack-face pressure, off-center cracks, restraint of pressure-induced bending, cracks in thickness transition regions, weld residual stresses, crack-morphology models, and thermal-hydraulic analysis, were also investigated. 140 refs., 105 figs., 41 tabs

  5. Calculation of stress intensity factors for circumferential semi-elliptical cracks with high aspect ratio in pipes

    International Nuclear Information System (INIS)

    Zareei, A.; Nabavi, S.M.

    2016-01-01

    In this paper, stress intensity factors are calculated at the deepest point of an internal circumferential semi-elliptical crack in a pipe subjected to any arbitrary load. Based on the three dimensional finite element analysis, a weight function is proposed for high aspect ratio semi-elliptical cracks in pipes. An effective expression is developed analytically to evaluate the stress intensity factor using the weight function method. For several crack face stress fields and welding residual stress distributions, the weight function is validated against finite element data and those in the literature. Based on the comparison results, it can be concluded that the solution proposed in this paper is effective in engineering applications. - Highlights: • Analysis of internal circumferential semi-elliptical cracks with high aspect ratio in pipes. • A weight function is proposed for the calculation of the stress intensity factors for the deepest point of the crack. • An effective closed form expression is proposed to evaluate the stress intensity factors. • Prediction of stress intensity factors for any applied stress gradients through the wall thickness without any limitations. • A three-dimensional finite element modeling employs to calculate the stress intensity factors for different geometries.

  6. An appraisal of procedures used to give the criterion for instability of a through-wall circumferential crack in a stainless steel piping system

    International Nuclear Information System (INIS)

    Smith, E.

    1989-01-01

    Against the background of the problem of intergranular stress corrosion cracking of 304 stainless steel in Boiling Water Reactor piping systems, this paper presents a critical appraisal of procedures that are currently used to give the criterion for instability of a through-wall circumferential crack in a stainless steel piping system. Particular attention is focussed on a simple procedure developed by Cotter, Chang and Zahoor, which has been applied to specific piping systems, the objective being to underpin its viability. The considerations are applicable to not only Boiling Water Reactor piping systems, but to other piping systems where pipe failure due to circumferential cracking is a potential problem. (author)

  7. Time displacement pictures with multi-mode probes from circumferential welds

    International Nuclear Information System (INIS)

    Wustenberg, H.; Jaffrey, D.; Ludwig, B.; Bertus, N.; Erhard, A.

    1985-01-01

    If a creeping wave probe is applied to butt welds typical echo patterns from weld defects can be received. It seems possible that echoes from the geometric shape of the root or the crown and defect echoes can be separated by simple means. This has been the reason for the development of a special presentation of the echo patterns received by this multi-mode creeping wave probe. The so called time displacement pictures show the AD-converted A-scans in a gray scale along a line corresponding to the time axis of the propagation. Perpendicular to this time axis results obtained from displacement of the probe parallel to the weld are presented. This kind of picture immediately provides the whole A-scan information. This paper presents some first results on simulated welds with artificial defects and on circumferential welds with typical geometric imperfections

  8. Fracture behavior of short circumferentially surface-cracked pipe

    International Nuclear Information System (INIS)

    Krishnaswamy, P.; Scott, P.; Mohan, R.

    1995-11-01

    This topical report summarizes the work performed for the Nuclear Regulatory Comniission's (NRC) research program entitled ''Short Cracks in Piping and Piping Welds'' that specifically focuses on pipes with short, circumferential surface cracks. The following details are provided in this report: (i) material property deteminations, (ii) pipe fracture experiments, (iii) development, modification and validation of fracture analysis methods, and (iv) impact of this work on the ASME Section XI Flaw Evaluation Procedures. The material properties developed and used in the analysis of the experiments are included in this report and have been implemented into the NRC's PIFRAC database. Six full-scale pipe experiments were conducted during this program. The analyses methods reported here fall into three categories (i) limit-load approaches, (ii) design criteria, and (iii) elastic-plastic fracture methods. These methods were evaluated by comparing the analytical predictions with experimental data. The results, using 44 pipe experiments from this and other programs, showed that the SC.TNP1 and DPZP analyses were the most accurate in predicting maximum load. New Z-factors were developed using these methods. These are being considered for updating the ASME Section XI criteria

  9. Transient thermal stress problem for a circumferentially cracked hollow cylinder

    Science.gov (United States)

    Nied, H. F.; Erdogan, F.

    1982-01-01

    The transient thermal stress problem for a hollow elasticity cylinder containing an internal circumferential edge crack is considered. It is assumed that the problem is axisymmetric with regard to the crack geometry and the loading, and that the inertia effects are negligible. The problem is solved for a cylinder which is suddenly cooled from inside. First the transient temperature and stress distributions in an uncracked cylinder are calculated. By using the equal and opposite of this thermal stress as the crack surface traction in the isothermal cylinder the crack problem is then solved and the stress intensity factor is calculated. The numerical results are obtained as a function of the Fourier number tD/b(2) representing the time for various inner-to-outer radius ratios and relative crack depths, where D and b are respectively the coefficient of diffusivity and the outer radius of the cylinder.

  10. Nonlinear Local Bending Response and Bulging Factors for Longitudinal and Circumferential Cracks in Pressurized Cylindrical Shells

    Science.gov (United States)

    Young, Richard D.; Rose, Cheryl A.; Starnes, James H., Jr.

    2000-01-01

    Results of a geometrically nonlinear finite element parametric study to determine curvature correction factors or bulging factors that account for increased stresses due to curvature for longitudinal and circumferential cracks in unstiffened pressurized cylindrical shells are presented. Geometric parameters varied in the study include the shell radius, the shell wall thickness, and the crack length. The major results are presented in the form of contour plots of the bulging factor as a function of two nondimensional parameters: the shell curvature parameter, lambda, which is a function of the shell geometry, Poisson's ratio, and the crack length; and a loading parameter, eta, which is a function of the shell geometry, material properties, and the applied internal pressure. These plots identify the ranges of the shell curvature and loading parameters for which the effects of geometric nonlinearity are significant. Simple empirical expressions for the bulging factor are then derived from the numerical results and shown to predict accurately the nonlinear response of shells with longitudinal and circumferential cracks. The numerical results are also compared with analytical solutions based on linear shallow shell theory for thin shells, and with some other semi-empirical solutions from the literature, and limitations on the use of these other expressions are suggested.

  11. Experimental verification on limit load estimation method for pipes with an arbitrary shaped circumferential surface flaw

    International Nuclear Information System (INIS)

    Li, Yinsheng; Hasegawa, Kunio; Miura, Naoki; Hoshino, Katsuaki

    2010-01-01

    When a flaw is detected in stainless steel pipes during in-service inspection, the limit load criterion given in the codes such as JSME Rules on Fitness-for-Service for Nuclear Power Plants or ASME Boiler and Pressure Vessel Code Section XI can be applied to evaluate the integrity of the pipe. However, in these codes, the limit load criterion is only provided for pipes containing a flaw with uniform depth, although many flaws with complicated shape such as stress corrosion cracking have been actually detected in pipes. In order to evaluate the integrity of the flawed pipes for general case, a limit load estimation method has been proposed by authors considering a circumferential surface flaw with arbitrary shape. The plastic collapse bending moment and corresponding stress are obtained by dividing the surface flaw into several segmented sub-flaws. In this paper, the proposed method was verified by comparing with experimental results. Four-point bending experiments were carried out for full scale stainless steel pipes with a symmetrical or non-symmetrical circumferential flaw. Estimated failure bending moments by the proposed method were found to be in good agreement with the experimental results, and the proposed method was confirmed to be effective for evaluating bending failure of pipes with flaw. (author)

  12. Failure behaviour of a piping system with a circumferentially orientated flaw

    International Nuclear Information System (INIS)

    Mikkola, T.P.J.; Diem, H.; Blind, D.; Hunger, H.

    1987-01-01

    The experiments were conducted on the recently installed feedwater line of the HDR reactor in Kahl. The investigations were focused on analysing both the crack propagation of a circumferentially flowed pipe under the influence of corrosion and cyclic load, together with the pipeline's subsequent failure behaviour. The experimental conditions were selected in a manner representing those which can, for example, prevait during start-up or shut-down of reactor. To this aim, the pipes were internally stressed with high pressure and temperature oxygenic water in conjunction with an externally applied bending moment. The investigations are supplemented by elastic-plastic triaxial finite element (FE) calculations for various assumed crack configurations, both prior to and following the experiments, thus granting a fracture-mechanical assessment of the structural behaviour. (orig./DG) [de

  13. Stepwise circumferential and focal ablation of Barrett's esophagus with high-grade dysplasia: results of the first prospective series of 11 patients

    NARCIS (Netherlands)

    Gondrie, J. J.; Pouw, R. E.; Sondermeijer, C. M. T.; Peters, F. P.; Curvers, W. L.; Rosmolen, W. D.; Krishnadath, K. K.; ten Kate, F.; Fockens, P.; Bergman, J. J.

    2008-01-01

    BACKGROUND AND STUDY AIMS: Stepwise circumferential and focal ablation of nondysplastic Barrett's esophagus has proven safe and effective. This study assessed the efficacy and safety of ablation for Barrett's esophagus with high-grade dysplasia (HGD), and residual Barrett's esophagus with dysplasia

  14. The Aerodynamic Performance of an Over-the-Rotor Liner With Circumferential Grooves on a High Bypass Ratio Turbofan Rotor

    Science.gov (United States)

    Bozak, Richard F.; Hughes, Christopher E.; Buckley, James

    2013-01-01

    While liners have been utilized throughout turbofan ducts to attenuate fan noise, additional attenuation is obtainable by placing an acoustic liner over-the-rotor. Previous experiments have shown significant fan performance losses when acoustic liners are installed over-the-rotor. The fan blades induce an oscillating flow in the acoustic liners which results in a performance loss near the blade tip. An over-the-rotor liner was designed with circumferential grooves between the fan blade tips and the acoustic liner to reduce the oscillating flow in the acoustic liner. An experiment was conducted in the W-8 Single-Stage Axial Compressor Facility at NASA Glenn Research Center on a 1.5 pressure ratio fan to evaluate the impact of this over-the-rotor treatment design on fan aerodynamic performance. The addition of a circumferentially grooved over-the-rotor design between the fan blades and the acoustic liner reduced the performance loss, in terms of fan adiabatic efficiency, to less than 1 percent which is within the repeatability of this experiment.

  15. Smooth muscle-like tissue constructs with circumferentially oriented cells formed by the cell fiber technology.

    Science.gov (United States)

    Hsiao, Amy Y; Okitsu, Teru; Onoe, Hiroaki; Kiyosawa, Mahiro; Teramae, Hiroki; Iwanaga, Shintaroh; Kazama, Tomohiko; Matsumoto, Taro; Takeuchi, Shoji

    2015-01-01

    The proper functioning of many organs and tissues containing smooth muscles greatly depends on the intricate organization of the smooth muscle cells oriented in appropriate directions. Consequently controlling the cellular orientation in three-dimensional (3D) cellular constructs is an important issue in engineering tissues of smooth muscles. However, the ability to precisely control the cellular orientation at the microscale cannot be achieved by various commonly used 3D tissue engineering building blocks such as spheroids. This paper presents the formation of coiled spring-shaped 3D cellular constructs containing circumferentially oriented smooth muscle-like cells differentiated from dedifferentiated fat (DFAT) cells. By using the cell fiber technology, DFAT cells suspended in a mixture of extracellular proteins possessing an optimized stiffness were encapsulated in the core region of alginate shell microfibers and uniformly aligned to the longitudinal direction. Upon differentiation induction to the smooth muscle lineage, DFAT cell fibers self-assembled to coiled spring structures where the cells became circumferentially oriented. By changing the initial core-shell microfiber diameter, we demonstrated that the spring pitch and diameter could be controlled. 21 days after differentiation induction, the cell fibers contained high percentages of ASMA-positive and calponin-positive cells. Our technology to create these smooth muscle-like spring constructs enabled precise control of cellular alignment and orientation in 3D. These constructs can further serve as tissue engineering building blocks for larger organs and cellular implants used in clinical treatments.

  16. Design and control of a novel gastroscope intervention mechanism with circumferentially pneumatic-driven clamping function.

    Science.gov (United States)

    Li, Yanmin; Liu, Hao; Hao, Siwen; Li, Hongyi; Han, Jianda; Yang, Yunsheng

    2017-03-01

    Robot-assisted manipulation is promising for solving problems such as understaffing and the risk of infection in gastro-intestinal endoscopy. However, the commonly used friction rollers in few existing systems have a potential risk of deforming flexible endoscopes for non-uniform clamping. This paper presents a robotic system for a standard flexible endoscope and focuses on a novel gastroscope intervention mechanism (GIM), which provides circumferentially uniform clamping with an airbag. The GIM works with a relay-on mechanism in a way similar to manual operation. The shear stiffness of airbag and the critical slipping force (CSF) were analysed to determine the parameters of the airbag. A fuzzy PID controller was employed to realize a fast response and high accuracy of pneumatic actuation. Experiments were performed to evaluate the accuracy, stiffness and CSF. In vitro and in vivo animal experiments were also carried out. The GIM realized an accuracy of 0.025 ± 0.2 mm and -0.03 ± 0.25° for push-pull and rotation without delivery resistance. Under polynomial could be used to describe the relationship between the CSF and pneumatic pressure. The novel GIM could effectively deliver gastroscopes. The pneumatic-driven clamping method proposed could protect the gastroscope by circumferentially uniform clamping force and the CSF could be properly controlled to guarantee operating safety. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Value of the magnetic resonance imaging in the assessment of the circumferential resection margin (CRM) in patients with rectal cancer

    International Nuclear Information System (INIS)

    Seehaus, A.; Fatal Jaef, V.; Pietrani, M.; Ocantos, J.

    2009-01-01

    Purpose: To determine whether magnetic resonance imaging (MRI) can predict tumor involvement of the circumferential resection margin (CRM) in patients with rectal cancer. Materials and methods: Between april 2005 and march 2008, 70 consecutive patients (mean age 64, range 34-78 years), 40 F and 30 M, with endoscopy and biopsy- proven middle and lower rectal cancer. Non contrast enhanced MRI was performed on a Siemens Avanto 1.5 T. A phased array coil was used and T2 weighted thin section sequences (TR/TE 4200/88, slice thickness 3mm, gap 0, matrix 256 x 256, field of view 150 x 150 mm) were performed in axial, sagittal and coronal orientations. Patients received a 150 ml glycerin enema before examination. No air insufflations or intramuscular antispasmodic was used. The shortest distance from the tumor edge to the circumferential margin was measured. A distance ≤ ?2 mm, analyzed in axial slices, was considered as definition of circumferential margin involvement. Results: The CRM was 2 mm in both MRI and histopathological findings in 26 patients. In 8 cases the CRM was shorter on MRI than in histopathological sections. In 32 patients the CRM was respected in both exams and 4 patients were considered positive on histopathological findings but negative in MRI. The sensitivity, specificity, positive and negative predictive values for prediction of tumor involvement of CRM were 86%, 80%, 76% and 88%, respectively. Conclusions: MRI gives reliable information on tumor involvement of the CRM in patients with rectal cancer. This may provide accurate identification of an important prognostic risk factor in patients prior to surgical treatment. (authors) [es

  18. Transpedicular fixation and fusion-arthrodesis circumferential for the treatment of lumbosacral spondylolisthesis of high degree - Multi centric experience

    International Nuclear Information System (INIS)

    Javier Matta Ibarra; Mauricio Rozo Franco; Francisco Restrepo Suarez

    2004-01-01

    The objective is to present the high-grade lumbosacral spondylolisthesis surgical experience. Spondylolisthesis causes chronic disabling pain, postural alteration and/or motor and sensory deficits in the lower extremities. Surgical stabilization is recommended in symptomatic adult and even in children or adolescents without symptoms because of the deformity progression potential. Stabilization can be done with or without reduction of the slippage; reduction implies neurological damage risk, bone (loosening) or implant (rupture) failure. Many authors recommended to do an in situ circumferential fusion arthrosis (inter body and inter transverse) associated with a transpedicular fixation in order to minimize the described risk. Eight patients were operated from 1993 to 2002. spondylolisthesis was analyzed according to clinical presentation, neurological dysfunction, postural alterations (slip angle, sacral inclination) complications and follow up. During follow up solid fusion was obtained with a better neurological function in all cases. One patient presented with a drop foot that reverted posteriorly; other patient had a superficial infection of the wound that was controlled. Slip angle improved between 8 - 42 and sacral inclination to 20 degrades. Present technique is recommended because it can be done a circumferential in situ arthrodesis in a single stage operation

  19. Failure maps for internally pressurized Zr-2.5% Nb pressure tubes with circumferential temperature variations

    International Nuclear Information System (INIS)

    Shewfelt, R.S.W.

    1986-01-01

    During some postulated loss-of-coolant accidents, the pressure tube temperature may rise before the internal pressure drops, causing the pressure tube to balloon. The temperature around the pressure tube circumference would likely be nonuniform, producing localized deformation that could possibly cause failure. The computer program, GRAD, was used to determine the circumferential temperature distribution required to cause an internally pressurized Zr-2.5% Nb pressure tube to fail before coming into full contact with its calandria tube. These results were used to construct failure maps. 7 refs

  20. Circumferential nonuniformity of cladding radiation swelling of fast reactor peripheral fuel elements

    International Nuclear Information System (INIS)

    Reutov, V.F.; Farkhutdinov, K.G.

    1977-01-01

    The results are presented of the investigation into the perimeter radiation swelling of Kh18N10T stainless steel cladding in different cross sections of a peripheral fuel element of the BR-5 reactor. The fluence on the cladding is 1.8-2.9 x 10 22 fast neutr/cm 2 , the operating temperatures in different parts of the fuel element being 430 deg to 585 deg C. There has been observed circumferential non-uniformity of the distribution, concentration, and of the total volume of radiation cavities, which is due to temperature non-uniformity along the cladding perimeter. It is shown that such non-uniformity of radiation swelling of the cladding material may result in bending of the peripheral fuel element with regard to the fuel assembly sheath walls

  1. Circumferential bone loss around splinted and nonsplinted immediately loaded implants retaining mandibular overdentures: A randomized controlled clinical trial using cone beam computed tomography.

    Science.gov (United States)

    Elsyad, Moustafa Abdou; Khirallah, Ahmed Samir

    2016-11-01

    Circumferential marginal bone around 2 splinted and nonsplinted immediately loaded implants in the edentulous mandible has not been previously investigated. The purpose of this randomized controlled clinical trial was to assess circumferential bone loss around splinted and nonsplinted immediately loaded implants retaining mandibular overdentures, using cone beam computed tomography (CBCT). Thirty participants with complete edentulism were allocated to 2 groups and received 2 implants in the canine region of the mandible. Implants were either left nonsplinted (with ball attachment [BA]) or splinted (with bar attachment [RA]). Mandibular overdentures were connected to the implants 1 week later. CBCT was used to evaluate vertical bone loss (VBL) and horizontal bone loss (HBLo) bone loss at the distal (D), buccal (B), mesial (M), and lingual (L) sites of each implant upon overdenture insertion (baseline, T0), 1 year (T1) and 3 years (T3) after insertion. Repeated measures ANOVA was used for statistical analysis (α=.05). No significant difference in the survival rate (93.3% for BA and 100% for RA) was found between groups (P=.156). VBL and HBLo increased significantly at T3 compared with T1 for both groups (Poverdentures were associated with significantly higher vertical and horizontal circumferential bone loss than those associated with splinted implants after a follow-up of 3 years. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Cerebral hemodynamic difference between early- and late-onset Alzheimer's disease by circumferential profile analysis with 123I-IMP brain SPECT

    International Nuclear Information System (INIS)

    Arai, Hisayuki; Hanyu, Haruo; Abe, Shinei; Asano, Tetsuichi; Takasaki, Masaru; Suzuki, Takanari; Abe, Kimihiko; Katsunuma, Hideyo.

    1992-01-01

    We conducted investigation to determine whether early- and late-onset Alzheimer's diseases differ pathophysiologically. Five patients with the early-onset (65 years and under) of the disease and 11 with the late-onset (65 years and over) of the disease were studied by single photon emission CT (SPECT) with N-isopropyl-p-[ 123 I]iodoamphetamine (IMP). Circumferential profile analysis (CPA) was performed to examine differences in the predominant hypoperfusion in the temporoparietal lobe, which is considered to be functionally damaged the most in Alzheimer's disease. The Xm values, calculated from gradients between the motorsensory or occipital cortices and temporoparietal cortex in the circumferential profile curve, were compared in both groups. The Xm values for patients with early- and late-onset Alzheimer's disease were 6.81±2.10 (counts/degree) and 3.28±1.58, respectively, the difference being significant. Our results suggest that functional abnormalities in the temporoparietal area severer in early- than late-onset Alzheimer's disease and that the application of CPA to IMP SPECT is useful to elucidate the pathophysiological difference between each of the disease. (author)

  3. Deficient Circumferential Growth Is the Primary Determinant of Aortic Obstruction Attributable to Partial Elastin Deficiency.

    Science.gov (United States)

    Jiao, Yang; Li, Guangxin; Korneva, Arina; Caulk, Alexander W; Qin, Lingfeng; Bersi, Matthew R; Li, Qingle; Li, Wei; Mecham, Robert P; Humphrey, Jay D; Tellides, George

    2017-05-01

    Williams syndrome is characterized by obstructive aortopathy attributable to heterozygous loss of ELN , the gene encoding elastin. Lesions are thought to result primarily from excessive smooth muscle cell (SMC) proliferation and consequent medial expansion, although an initially smaller caliber and increased stiffness of the aorta may contribute to luminal narrowing. The relative contributions of such abnormalities to the obstructive phenotype had not been defined. We quantified determinants of luminal stenosis in thoracic aortas of Eln -/- mice incompletely rescued by human ELN . Moderate obstruction was largely because of deficient circumferential growth, most prominently of ascending segments, despite increased axial growth. Medial thickening was evident in these smaller diameter elastin-deficient aortas, with medial area similar to that of larger diameter control aortas. There was no difference in cross-sectional SMC number between mutant and wild-type genotypes at multiple stages of postnatal development. Decreased elastin content was associated with medial fibrosis and reduced aortic distensibility because of increased structural stiffness but preserved material stiffness. Elastin-deficient SMCs exhibited greater contractile-to-proliferative phenotypic modulation in vitro than in vivo. We confirmed increased medial collagen without evidence of increased medial area or SMC number in a small ascending aorta with thickened media of a Williams syndrome subject. Deficient circumferential growth is the predominant mechanism for moderate obstructive aortic disease resulting from partial elastin deficiency. Our findings suggest that diverse aortic manifestations in Williams syndrome result from graded elastin content, and SMC hyperplasia causing medial expansion requires additional elastin loss superimposed on ELN haploinsufficiency. © 2017 American Heart Association, Inc.

  4. Instability predictions for circumferentially cracked Type-304 stainless-steel pipes under dynamic loading. Final report

    International Nuclear Information System (INIS)

    Zahoor, A.; Wilkowski, G.; Abou-Sayed, I.; Marschall, C.; Broek, D.; Sampath, S.; Rhee, H.; Ahmad, J.

    1982-04-01

    This report provides methods to predict margins of safety for circumferentially cracked Type 304 stainless steel pipes subjected to applied bending loads. An integrated combination of experimentation and analysis research was pursued. Two types of experiments were performed: (1) laboratory-scale tests on center-cracked panels and bend specimens to establish the basic mechanical and fracture properties of Type 304 stainless steel, and (2) full-scale pipe fracture tests under quasi-static and dynamic loadings to assess the analysis procedures. Analyses were based upon the simple plastic collapse criterion, a J-estimation procedure, and elastic-plastic large-deformation finite element models

  5. Effects of circumferential rigid wrist orthoses in rehabilitation of patients with radius fracture at typical site

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2005-01-01

    Full Text Available Background. The use of orthoses is a questionable rehabilitation method for patients with the distal radius fracture at typical site. The aim of this study was to compare the effects of the rehabilitation on patients with radius fracture at the typical site, who wore circumferential static wrist orthoses, with those who did not wear them. Methods. Thirty patients were divided into 3 equal groups, 2 experimental groups, and 1 control group. The patients in the experimental groups were given the rehabilitation program of wearing serially manufactured (off-the-shelf, as well as custom-fit orthoses. Those in the control group did not wear wrist orthoses. Evaluation parameters were pain, edema, the range of the wrist motion, the quality of cylindrical, spherical, and pinch-spherical grasp, the strength of pinch and hand grasp, and patient's assessment of the effects of rehabilitation. Results. No significant difference in the effects of rehabilitation on the patients in experimental groups as opposed to control group was found. Patients in the first experimental group, and in control group were more satisfied with the effects of rehabilitation, as opposed to the patients in the second experimental group (p<0,05. Conclusion. The effects of circumferential static wrist orthoses in the rehabilitation of patients with distal radius fracture at the typical site were not clinically significant. There was no significant difference between the custom and off-the-shelf orthoses.

  6. Cylindrical magnetization model for glass-coated microwires with circumferential anisotropy: Comparison with experiments and skin effect

    Energy Technology Data Exchange (ETDEWEB)

    Torrejon, J., E-mail: torrejondiaz.jacob@nims.go.jp [Laboratoire de Physique des Solides, Univ. Paris-Sud, CNRS UMR 8502, 91405 Orsay (France); Instituto de Ciencia de Materiales, CSIC, 28049 Madrid (Spain); Thiaville, A. [Laboratoire de Physique des Solides, Univ. Paris-Sud, CNRS UMR 8502, 91405 Orsay (France); Adenot-Engelvin, A.-L. [CEA, DAM, Le Ripault, 37260 Monts (France); Vazquez, M. [Instituto de Ciencia de Materiales, CSIC, 28049 Madrid (Spain)

    2014-05-01

    The present manuscript represents the third part of a series of studies about a continuous micromagnetic model for amorphous microwires with non-uniform magnetic structure (Torrejon et al., J. Magn. Magn. Mater. 323 (2011) 283; Torrejon et al., J. Magn. Magn. Mater. 333 (2013) 144). Here we compare the predictions of this model with experiments, and show the validity of this approach when a uniform magnetic structure in the microwire cannot be considered. The analyzed microwires exhibit ultrasoft magnetic behaviour and negative magnetostriction, with a non-uniform magnetic structure composed of an axially magnetized inner core exchange-coupled with a circumferentially magnetized outer shell. The static properties were obtained by magnetometry. The high frequency response, axial permeability, was measured from a conventional single coil permeameter connected to a network analyzer. The microwave response is strongly affected by skin effect, which therefore needs to be taken into account for comparison with theory. The validity of the continuous model is proved through the experimental dependence of the permeability on axial static field. Finally, the efficient dynamic magnetization is evaluated from the imaginary component of permeability. - Highlights: • We model magnetic properties of microwires with circumferential anisotropy. • Skin effect correction has to be considered for small microwires. • Validity of model is proved by permeability dependence on axial static field. • Wires with small volume of the core can be well described by macrospin approach. • The exchange-coupled continuous core-shell model is compared to experiments.

  7. Transient Stress Intensity Factors of Functionally Graded Hollow Cylinders with Internal Circumferential Cracks

    Directory of Open Access Journals (Sweden)

    Iman Eshraghi

    Full Text Available Abstract In this paper, transient thermomechanical stress intensity factors for functionally graded cylinders with complete internal circumferential cracks are obtained using the weight function method. The finite difference method is used to calculate the time dependent temperature distribution and thermal stresses along the cylinder thickness. Furthermore, finite element analysis is performed to determine the weight function coefficients and to investigate the accuracy of the predicted stress intensity factors from the weight functions. Variation of the stress intensity factors with time and effects of the material gradation on the results are investigated, as well. It is shown that the proposed technique can be used to accurately predict transient thermomechanical stress intensity factors for functionally graded cylinders with arbitrary material gradation.

  8. A comparison between Philips and Tomtec for left ventricular deformation and volume measurements in neonatal intensive care patients.

    Science.gov (United States)

    de Waal, Koert; Phad, Nilkant

    2018-03-01

    Two-dimensional speckle tracking echocardiography is an emerging technique for analyzing cardiac function in newborns. Strain is a highly reliable and reproducible parameter, and reference values have been established for term and preterm newborns. Its implementation into clinical practice has been slow, partly due to lack of inter-vendor consistency. Our aim was to compare recent versions of Philips and Tomtec speckle tracking software for deformation and semiautomated volume and area measurements in neonatal intensive care patients. Longitudinal and circumferential deformation and cavity dimensions (volume, area) were determined off line from apical and short-axis images in 50 consecutive newborns with a median birthweight of 760 g (range 460-3200 g). Absolute mean endocardial global longitudinal strain measurements were similar between vendors, but with wide limits of agreement (Philips -18.9 [2.1]%, Tomtec -18.6 [2.5]%, bias -0.3 [1.7]%, and limits of agreement -3.6%-3.1%). Longitudinal strain rate and circumferential measurements showed poor correlation. All volume and area measurements correlated well between the vendors, but with significant bias. Global longitudinal strain measurements compared well between vendors but wide limits of agreement, suggesting that longitudinal measurements are preferred using similar hardware and software. © 2017, Wiley Periodicals, Inc.

  9. Id4 functions downstream of Bmp signaling to restrict TCF function in endocardial cells during atrioventricular valve development.

    Science.gov (United States)

    Ahuja, Suchit; Dogra, Deepika; Stainier, Didier Y R; Reischauer, Sven

    2016-04-01

    The atrioventricular canal (AVC) connects the atrial and ventricular chambers of the heart and its formation is critical for the development of the cardiac valves, chamber septation and formation of the cardiac conduction system. Consequently, problems in AVC formation can lead to congenital defects ranging from cardiac arrhythmia to incomplete cardiac septation. While our knowledge about early heart tube formation is relatively comprehensive, much remains to be investigated about the genes that regulate AVC formation. Here we identify a new role for the basic helix-loop-helix factor Id4 in zebrafish AVC valve development and function. id4 is first expressed in the AVC endocardium and later becomes more highly expressed in the atrial chamber. TALEN induced inactivation of id4 causes retrograde blood flow at the AV canal under heat induced stress conditions, indicating defects in AV valve function. At the molecular level, we found that id4 inactivation causes misexpression of several genes important for AVC and AV valve formation including bmp4 and spp1. We further show that id4 appears to control the number of endocardial cells that contribute to the AV valves by regulating Wnt signaling in the developing AVC endocardium. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Influence of operating conditions and atomizer design on circumferential liquid distribution from small pressure-swirl atomizer

    Science.gov (United States)

    Malý, Milan; Janáčková, Lada; Jedelský, Jan; Jícha, Miroslav

    The spray symmetry is an important aspect in most practical applications. However, it is often an overlooked parameter. A measurement of circumferential distribution was carried out by a circular-sectored vessel on several pressure-swirl atomizers with spill-line over a wide range of injection pressure. The obtained results show that the spray uniformity improves markedly with the injection pressure. The increase in a number of tangential entry ports has only a minor effect on the spray uniformity. Even a small mechanical corruption of the atomizer internal parts negatively affects the spray patternation.

  11. Amniotic membrane grafts for the prevention of esophageal stricture after circumferential endoscopic submucosal dissection.

    Science.gov (United States)

    Barret, Maximilien; Pratico, Carlos Alberto; Camus, Marine; Beuvon, Frédéric; Jarraya, Mohamed; Nicco, Carole; Mangialavori, Luigi; Chaussade, Stanislas; Batteux, Frédéric; Prat, Frédéric

    2014-01-01

    The prevention of esophageal strictures following circumferential mucosal resection remains a major clinical challenge. Human amniotic membrane (AM) is an easily available material, which is widely used in ophthalmology due to its wound healing, anti-inflammatory and anti-fibrotic properties. We studied the effect of AM grafts in the prevention of esophageal stricture after endoscopic submucosal dissection (ESD) in a swine model. In this prospective, randomized controlled trial, 20 swine underwent a 5 cm-long circumferential ESD of the lower esophagus. In the AM Group (n = 10), amniotic membrane grafts were placed on esophageal stents; a subgroup of 5 swine (AM 1 group) was sacrificed on day 14, whereas the other 5 animals (AM 2 group) were kept alive. The esophageal stent (ES) group (n = 5) had ES placement alone after ESD. Another 5 animals served as a control group with only ESD. The prevalence of symptomatic strictures at day 14 was significantly reduced in the AM group and ES groups vs. the control group (33%, 40% and 100%, respectively, p = 0.03); mean esophageal diameter was 5.8±3.6 mm, 6.8±3.3 mm, and 2.6±1.7 mm for AM, ES, and control groups, respectively. Median (range) esophageal fibrosis thickness was 0.87 mm (0.78-1.72), 1.19 mm (0.28-1.95), and 1.65 mm (0.7-1.79) for AM 1, ES, and control groups, respectively. All animals had developed esophageal strictures by day 35. The anti-fibrotic effect of AM on esophageal wound healing after ESD delayed the development of esophageal stricture in our model. However, this benefit was of limited duration in the conditions of our study.

  12. Amniotic membrane grafts for the prevention of esophageal stricture after circumferential endoscopic submucosal dissection.

    Directory of Open Access Journals (Sweden)

    Maximilien Barret

    Full Text Available The prevention of esophageal strictures following circumferential mucosal resection remains a major clinical challenge. Human amniotic membrane (AM is an easily available material, which is widely used in ophthalmology due to its wound healing, anti-inflammatory and anti-fibrotic properties. We studied the effect of AM grafts in the prevention of esophageal stricture after endoscopic submucosal dissection (ESD in a swine model.In this prospective, randomized controlled trial, 20 swine underwent a 5 cm-long circumferential ESD of the lower esophagus. In the AM Group (n = 10, amniotic membrane grafts were placed on esophageal stents; a subgroup of 5 swine (AM 1 group was sacrificed on day 14, whereas the other 5 animals (AM 2 group were kept alive. The esophageal stent (ES group (n = 5 had ES placement alone after ESD. Another 5 animals served as a control group with only ESD.The prevalence of symptomatic strictures at day 14 was significantly reduced in the AM group and ES groups vs. the control group (33%, 40% and 100%, respectively, p = 0.03; mean esophageal diameter was 5.8±3.6 mm, 6.8±3.3 mm, and 2.6±1.7 mm for AM, ES, and control groups, respectively. Median (range esophageal fibrosis thickness was 0.87 mm (0.78-1.72, 1.19 mm (0.28-1.95, and 1.65 mm (0.7-1.79 for AM 1, ES, and control groups, respectively. All animals had developed esophageal strictures by day 35.The anti-fibrotic effect of AM on esophageal wound healing after ESD delayed the development of esophageal stricture in our model. However, this benefit was of limited duration in the conditions of our study.

  13. LONG-TERM EFFICACY AND HEALTH STATUS IN PATIENTS WITH ATRIAL FIBRILLATION AFTER RADIOFREQUENCY ENDOCARDIAL CATHETER ABLATION IN MAZE REGIMEN

    Directory of Open Access Journals (Sweden)

    M. E. Protasov

    2015-01-01

    Full Text Available Aim: To evaluate efficacy of endocardial radiofrequency catheter ablation (RFA in atrial fibrillation (AF in Maze regimen, to assess patients’ health status with a European Quality of Life Questionnaire (EQ-5D and cardiovascular mortality in patients after the intervention taking anticoagulants.Materials and methods: 391 patients with AF (247 of them males aged from 18 to 77 years (mean age 54.9 ± 10.1 years were examined and got treatment. All patients underwent RFA, including pulmonary vein isolation, linear ablations of the posterior wall, left atrial roof and mitral isthmus. Their health status was assessed according to efficacy of the intervention and data from EQ-5D questionnaires.Results: At 3 and 36 months after the intervention, RFA efficacy in patients with paroxysmal AF was 92% and 83.3%, respectively, and in patients with persistent AF, 89.7% and 72.4%. According to EQ-5D “thermometer”, after 36 months patients with successful catheter ablation assessed their health status as being approximately at the same level as during initial hospitalization, i.e., in patients with paroxysmal AF this scale scored at 79.74% and 81.4%, and in patients with persistent AF, at 79.94% and 81.06%, respectively. However, if the endocardial Maze procedure was unsuccessful, there was a deterioration of health status from 80.8% to 70.14% in patients with paroxysmal AF and from 77.82% to 69.46% in those with persistent AF. The same trend was observed in the analysis of other EQ-5D items. All-cause cardiovascular mortality in the subgroup with successful RFA was lower than in the subgroup with unsuccessful RFA, irrespective of AF form (p < 0.001. A 36-month mortality rate in patients with paroxysmal AF after a successful RFA was 2.1% and in patients with persistent AF, 1.2%, after unsuccessful RFA the corresponding values being 13.4% and 9.6%. Causes of death in patients with successful and unsuccessful RFA were different. After successful RFA for

  14. Recent investigations and tests with the BBR winding system for circumferential prestressing of concrete vessels and containments

    International Nuclear Information System (INIS)

    Schuett, K.; Speck, F.E.

    1993-01-01

    Prestressed concrete pressure vessels for nuclear power stations need post-tensioning systems of large capacity. For the circumferential prestressing, the continuous winding of prestressing steel has several advantages when compared to the use of large numbers of single tendons. About 15 years ago Bureau BBR Ltd (Zuerich) developed the winding system SW 8500. The further development work interrupted at that time for lack of immediate applications was resumed 4 years ago by Bureau BBR together with SUSPA on the ground of new projects being evaluated

  15. Ductile fracture of circumferentially cracked type-304 stainless steel pipes in tension

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.; Norris, D.M.

    1984-11-01

    Circumferentially cracked pipes subjected to tensile load were analyzed for finite length and constant depth part-through cracks located at the inside of the pipe wall. The analysis postulated loads sufficient to cause net-section yielding of the flawed section. It was demonstrated that a propensity for predominantly radial growth exists for part-through cracks loaded in tension. This result is similar to the result for bend loading, except that bend loading causes more favorable conditions for wall breakthrough than tension loading. Numerical results were developed for 4-in. and 24-in-dia pipes. Safety margins for displacement controlled loads were described by a safety assessment diagram. This diagram defines a curve delineating leak from fracture in a space of nondimensional crack length and crack depth. 4-india schedule 80 Type-304 stainless steel pipes with length to radius ratio (L/R) of up to 100 exhibited leak-before-break behavior.

  16. Ductile fracture of circumferentially cracked type-304 stainless steel pipes in tension

    International Nuclear Information System (INIS)

    Zahoor, A.; Norris, D.M.

    1984-01-01

    Circumferentially cracked pipes subjected to tensile load were analyzed for finite length and constant depth part-through cracks located at the inside of the pipe wall. The analysis postulated loads sufficient to cause net-section yielding of the flawed section. It was demonstrated that a propensity for predominantly radial growth exists for part-through cracks loaded in tension. This result is similar to the result for bend loading, except that bend loading causes more favorable conditions for wall breakthrough than tension loading. Numerical results were developed for 4-in. and 24-in-dia pipes. Safety margins for displacement controlled loads were described by a safety assessment diagram. This diagram defines a curve delineating leak from fracture in a space of nondimensional crack length and crack depth. 4-india schedule 80 Type-304 stainless steel pipes with length to radius ratio (L/R) of up to 100 exhibited leak-before-break behavior

  17. Blade row dynamic digital compression program. Volume 2: J85 circumferential distortion redistribution model, effect of Stator characteristics, and stage characteristics sensitivity study

    Science.gov (United States)

    Tesch, W. A.; Steenken, W. G.

    1978-01-01

    The results of dynamic digital blade row compressor model studies of a J85-13 engine are reported. The initial portion of the study was concerned with the calculation of the circumferential redistribution effects in the blade-free volumes forward and aft of the compression component. Although blade-free redistribution effects were estimated, no significant improvement over the parallel-compressor type solution in the prediction of total-pressure inlet distortion stability limit was obtained for the J85-13 engine. Further analysis was directed to identifying the rotor dynamic response to spatial circumferential distortions. Inclusion of the rotor dynamic response led to a considerable gain in the ability of the model to match the test data. The impact of variable stator loss on the prediction of the stability limit was evaluated. An assessment of measurement error on the derivation of the stage characteristics and predicted stability limit of the compressor was also performed.

  18. Plastic fracture mechanics prediction of fracture instability in a circumferentially cracked pipe in bending - 1. J-integral analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.; Kanninen, M.F.

    1981-11-01

    A method of evaluating the J-integral for a circumferentially cracked pipe in bending is proposed. The method allows a J-resistance curve to be evaluated directly from the load-displacement record obtained in a pipe fracture experiment. It permits an analysis for fracture instability in a circumferential crack growth using a J-resistance curve and the tearing modulus parameter. The influence of the system compliance on fracture instability is discussed in conjunction with the latter application. The importance of using a J-resistance curve that is consistent with the type of constraint for a given application is emphasized. The possibility of a pipe fracture emanating from a stress corrosion crack in the heat-affected zones of girth-welds in Type 304 stainless steel pipes was investigated. The J-resistance curve was employed. A pipe fracture experiment was performed using a spring-loaded four-point bending system that simulated an 8.8-m long section of unsupported 102-mm-dia pipe. An initial through-wall crack of length equal to 104 mm was used. Fracture instability was predicted to occur between 15.2 and 22.1 mm of stable crack growth at each tip. In the actual experiment, the onset of fracture instability occurred beyond maximum load at an average stable crack growth of 11.7 to 19 mm at each tip. 24 refs.

  19. Plastic fracture mechanics prediction of fracture instability in a circumferentially cracked pipe in bending - 1. J-integral analysis

    International Nuclear Information System (INIS)

    Zahoor, A.; Kanninen, M.F.

    1981-01-01

    A method of evaluating the J-integral for a circumferentially cracked pipe in bending is proposed. The method allows a J-resistance curve to be evaluated directly from the load-displacement record obtained in a pipe fracture experiment. It permits an analysis for fracture instability in a circumferential crack growth using a J-resistance curve and the tearing modulus parameter. The influence of the system compliance on fracture instability is discussed in conjunction with the latter application. The importance of using a J-resistance curve that is consistent with the type of constraint for a given application is emphasized. The possibility of a pipe fracture emanating from a stress corrosion crack in the heat-affected zones of girth-welds in Type 304 stainless steel pipes was investigated. The J-resistance curve was employed. A pipe fracture experiment was performed using a spring-loaded four-point bending system that simulated an 8.8-m long section of unsupported 102-mm-dia pipe. An initial through-wall crack of length equal to 104 mm was used. Fracture instability was predicted to occur between 15.2 and 22.1 mm of stable crack growth at each tip. In the actual experiment, the onset of fracture instability occurred beyond maximum load at an average stable crack growth of 11.7 to 19 mm at each tip. 24 refs

  20. Influence of operating conditions and atomizer design on circumferential liquid distribution from small pressure-swirl atomizer

    Directory of Open Access Journals (Sweden)

    Malý Milan

    2017-01-01

    Full Text Available The spray symmetry is an important aspect in most practical applications. However, it is often an overlooked parameter. A measurement of circumferential distribution was carried out by a circular-sectored vessel on several pressure-swirl atomizers with spill-line over a wide range of injection pressure. The obtained results show that the spray uniformity improves markedly with the injection pressure. The increase in a number of tangential entry ports has only a minor effect on the spray uniformity. Even a small mechanical corruption of the atomizer internal parts negatively affects the spray patternation.

  1. Instability predictions for circumferentially cracked Type-304 stainless-steel pipes under dynamic loading. Final report. [BWR

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.; Wilkowski, G.; Abou-Sayed, I.; Marschall, C.; Broek, D.; Sampath, S.; Rhee, H.; Ahmad, J.

    1982-04-01

    This report provides methods to predict margins of safety for circumferentially cracked Type 304 stainless steel pipes subjected to applied bending loads. An integrated combination of experimentation and analysis research was pursued. Two types of experiments were performed: (1) laboratory-scale tests on center-cracked panels and bend specimens to establish the basic mechanical and fracture properties of Type 304 stainless steel, and (2) full-scale pipe fracture tests under quasi-static and dynamic loadings to assess the analysis procedures. Analyses were based upon the simple plastic collapse criterion, a J-estimation procedure, and elastic-plastic large-deformation finite element models.

  2. Contribution to the Evaluation of the Circumferentially-Cracked Round Bar for Fracture Toughness Determination of Reactor Pressure

    International Nuclear Information System (INIS)

    Scibetta, M.

    1999-06-01

    The subject of this PhD dissertation is the use of the Circumferentially-Cracked Round Bar (CRB) for fracture toughness measurements. The main advantages of CRB are the relatively small size requirements of the testing specimens, the low cost to machine the specimen, the rotating bending fatigue allowing for easy precracking of specimens, the use of standard tensile test fixture and the axisymmetry of the specimen that avoids time consuming 3D finite element calculations. An in-depth study of the most widely used precracking technique for CRB, namely the rotating bending fatigue, is made

  3. Contribution to the Evaluation of the Circumferentially-Cracked Round Bar for Fracture Toughness Determination of Reactor Pressure

    Energy Technology Data Exchange (ETDEWEB)

    Scibetta, M

    1999-06-01

    The subject of this PhD dissertation is the use of the Circumferentially-Cracked Round Bar (CRB) for fracture toughness measurements. The main advantages of CRB are the relatively small size requirements of the testing specimens, the low cost to machine the specimen, the rotating bending fatigue allowing for easy precracking of specimens, the use of standard tensile test fixture and the axisymmetry of the specimen that avoids time consuming 3D finite element calculations. An in-depth study of the most widely used precracking technique for CRB, namely the rotating bending fatigue, is made.

  4. Stress intensity magnification factors for fully circumferential cracks in valve bodies (thick cylinders)

    International Nuclear Information System (INIS)

    Toor, P.M.

    1998-01-01

    The stress intensity solutions presented herein were obtained using an energy method in conjunction with a two-dimensional finite element program in order to explicitly account for curvature effect for fully circumferential cracks. The magnification factors for a specific crack depth were calculated by successively loading the crack surface by a uniform, linear, quadratic, and a cubic loading distribution. The magnification factors can be used to calculate the stress intensity factors by superposition method. The functions for each load condition in terms of radius to thickness ratio (R/t) and a fractional distance in terms of crack depth to thickness ratio (a/t) were developed. The validity of these functions is R/t = 1.5 to 10.0 and for 0.0125 ≤ a/t ≤ 0.8125. The functions agree to within 1% of the finite elements solutions for most magnification factors

  5. Leak before break behaviour of austenitic and ferritic pipes containing circumferential defects

    Energy Technology Data Exchange (ETDEWEB)

    Stadtmueller, W.; Sturm, D.

    1997-04-01

    Several research projects carried out at MPA Stuttgart to investigate the Leak-before-Break (LBB) behavior of safety relevant pressure bearing components are summarized. Results presented relate to pipes containing circumferential defects subjected to internal pressure and external bending loading. An overview of the experimentally determined results for ferritic components is presented. For components containing postulated or actual defects, the dependence of the critical loading limit on the defect size is shown in the form of LBB curves. These are determined experimentally and/or by calculation for through-wall slits, and represent the boundary curve between leakage and massive fracture. For surface defects and a given bending moment and internal pressure, no fracture will occur if the length at leakage remains smaller than the critical defect length given by the LBB curve for through-wall defects. The predictive capability of engineering calculational methods are presented by way of example. The investigation programs currently underway, testing techniques, and initial results are outlined.

  6. A rotordynamic analysis of circumferentially-grooved pump seals based on a three-control-volume theory

    International Nuclear Information System (INIS)

    Ha, Tae Woong; Lee, An Sung

    2000-01-01

    In this paper the leakage prediction and rotordynamic analysis of an annular seal with a smooth rotor and circumferentially grooved stator are performed based on a three-control-volume theory. The present analysis is validated by comparing with the experimental data of Iwatsubo and Sheng and theoretical results suggested by Marquette and Childs. For the leakage prediction the present analysis shows a good agreement with Marquette and Childs' result and a qualitation agreement with Iwatsubo and Shengs' experimental data. Direct and cross-coupled stiffness coefficients show closer agreement with the experimental values than those of Marquette and Childs. However, direct damping coefficient shows greater discrepancy from the experimental value than Marquette and Childs'

  7. Fracture toughness evaluation using circumferential notched tensile specimens by the tensile test and ANSYS software

    Energy Technology Data Exchange (ETDEWEB)

    Meydanlik, N. [Mechanical Engineering Department, Trakya University, Edirne (Turkey)

    2013-07-01

    Fracture toughness (K{sub Ic} ) is the most important parameter that defines mechanical behaviour of the materials using machine design. Since, fracture tests are both difficult and time consuming, the researchers have been investigating for the easier evaluation of K{sub Ic} for many years. In this work; K{sub Ic} values have been obtained by using ANSYS software based on the experimental values evaluated in the previous studies. It was shown that there is no significant difference between the experimental ones and the ones obtained by ANSYS. This procedure can provide an important advantage on obtaining of the K{sub IC} values. Key words: Fracture toughness (K{sub Ic} ), circumferential notched tensile specimens, ANSYS.

  8. Investigation on inlet recirculation characteristics of double suction centrifugal compressor with unsymmetrical inlet

    Science.gov (United States)

    Yang, Ce; Wang, Yingjun; Lao, Dazhong; Tong, Ding; Wei, Longyu; Liu, Yixiong

    2016-08-01

    The inlet recirculation characteristics of double suction centrifugal compressor with unsymmetrical inlet structures were studied in numerical method, mainly focused on three issues including the amounts and differences of the inlet recirculation in different working conditions, the circumferential non-uniform distributions of the inlet recirculation, the recirculation velocity distributions of the upstream slot of the rear impeller. The results show that there are some differences between the recirculation of the front impeller and that of the rear impeller in whole working conditions. In design speed, the recirculation flow rate of the rear impeller is larger than that of the front impeller in the large flow range, but in the small flow range, the recirculation flow rate of the rear impeller is smaller than that of the front impeller. In different working conditions, the recirculation velocity distributions of the front and rear impeller are non-uniform along the circumferential direction and their non-uniform extents are quite different. The circumferential non-uniform extent of the recirculation velocity varies with the working conditions change. The circumferential non-uniform extent of the recirculation velocity of front impeller and its distribution are determined by the static pressure distribution of the front impeller, but that of the rear impeller is decided by the coupling effects of the inlet flow distortion of the rear impeller, the circumferential unsymmetrical distribution of the upstream slot and the asymmetric structure of the volute. In the design flow and small flow conditions, the recirculation velocities at different circumferential positions of the mean line of the upstream slot cross-section of the rear impeller are quite different, and the recirculation velocities distribution forms at both sides of the mean line are different. The recirculation velocity distributions in the cross-section of the upstream slot depend on the static pressure

  9. Mechanisms of Left Ventricular Dysfunction Assessed by Layer-Specific Strain Analysis in Patients With Repaired Tetralogy of Fallot.

    Science.gov (United States)

    Yamada, Mariko; Takahashi, Ken; Kobayashi, Maki; Yazaki, Kana; Takayasu, Hirobumi; Akimoto, Katsumi; Kishiro, Masahiko; Inage, Akio; Yoshikawa, Tadahiro; Park, In-Sam; Nakanishi, Keisuke; Kawasaki, Shiori; Shimizu, Toshiaki

    2017-05-25

    Left ventricular (LV) dysfunction in patients with repaired tetralogy of Fallot (rTOF) is an important risk factor for adverse outcomes. The aim of this study was to assess the details and time course of such LV dysfunction using layer-specific strain analysis by echocardiography.Methods and Results:The 66 patients with rTOF (mean age, 16.3±9.3 years) were divided into 3 groups (T1: 4-10 years, T2: 11-20 years, T3: 21-43 years), and 113 controls of similar age (mean age, 17.2±9.3 years) were divided into 3 corresponding groups (C1, C2, and C3). Layer-specific longitudinal strain (LS) and circumferential strain (CS) of 3 myocardial layers (endocardial, midmyocardial, and epicardial) were determined by echocardiography. Basal and papillary endocardial CS values were decreased in T1 compared with C1. With the exception of papillary epicardial CS, basal/papillary CS and LS of all 3 layers decreased in T2 compared with C2. Excepting papillary epicardial CS, all other values were decreased in T3 compared with C3. Potential myocardial damage was found in the endocardium at the basal and papillary levels of the LV in young patients with rTOF, extending from the endocardium to the epicardium and from the base to the apex. This is the possible time course of LV dysfunction in patients with rTOF.

  10. Spontaneous slip reduction of low-grade isthmic spondylolisthesis following circumferential release via bilateral minimally invasive transforaminal lumbar interbody fusion: technical note and short-term outcome.

    Science.gov (United States)

    Pan, Jie; Li, Lijun; Qian, Lie; Zhou, Wei; Tan, Jun; Zou, Le; Yang, Mingjie

    2011-02-15

    STUDY DESIGN.: Retrospective clinical data analysis. OBJECTIVE.: To investigate and verify our philosophy of spontaneous slip reduction following circumferential release via bilateral minimally invasive transforaminal lumbar interbody fusion (Mini-TLIF) for treatment of low-grade symptomatic isthmic spondylolisthesis. SUMMARY OF BACKGROUND DATA.: Symptomatic isthmic spondylolisthesis usually requires surgical intervention, and the most currently controversial focus is on method and degree of reduction; and Mini-TLIF is an attractive surgical procedure for isthmic spondylolisthesis. METHODS.: Between February 2004 and June 2008, 21 patients with low-grade isthmic spondylolisthesis underwent Mini-TLIF in our institute. Total resection of the scar around the pars interarticularis liberated the nerve roots, achieving posterior release as well. The disc was thoroughly resected, and the disc space was gradually distracted and thoroughly released with sequential disc shavers until rupture of anulus conjunct with anterior longitudinal ligament, accomplishing anterior release, so as to insert Cages. Because of circumferential release, the slipped vertebrae would tend to obtain spontaneous reduction, and with pedicle screw fixation, additional reduction would be achieved without any application of posterior translation force. Radiographs, Visual Analogue Scale, and Oswestry Disability Index were documented. All the cases were followed up for 10 to 26 months. RESULTS.: Slip percentage was reduced from 24.2% ± 6.9% to 10.5% ± 4.0%, and foraminal area percentage increased from 89.1% ± 3.0% to 93.6% ± 2.1%. Visual Analogue Scale and Oswestry Disability Index decreased from 7.8 ± 1.5 to 2.1 ± 1.1 and from 53.3 ± 16.2 to 17.0 ± 7.8, respectively. No neurologic complications were encountered. There were no signs of instrumentation failure. The fusion rate approached 100%. CONCLUSION.: Slip reduction is based on circumferential release. The procedure can be well performed

  11. Circumferential targeted renal sympathetic nerve denervation with preservation of the renal arterial wall using intra-luminal ultrasound

    Science.gov (United States)

    Roth, Austin; Coleman, Leslie; Sakakura, Kenichi; Ladich, Elena; Virmani, Renu

    2015-03-01

    An intra-luminal ultrasound catheter system (ReCor Medical's Paradise System) has been developed to provide circumferential denervation of the renal sympathetic nerves, while preserving the renal arterial intimal and medial layers, in order to treat hypertension. The Paradise System features a cylindrical non-focused ultrasound transducer centered within a balloon that circulates cooling fluid and that outputs a uniform circumferential energy pattern designed to ablate tissues located 1-6 mm from the arterial wall and protect tissues within 1 mm. RF power and cooling flow rate are controlled by the Paradise Generator which can energize transducers in the 8.5-9.5 MHz frequency range. Computer simulations and tissue-mimicking phantom models were used to develop the proper power, cooling flow rate and sonication duration settings to provide consistent tissue ablation for renal arteries ranging from 5-8 mm in diameter. The modulation of these three parameters allows for control over the near-field (border of lesion closest to arterial wall) and far-field (border of lesion farthest from arterial wall, consisting of the adventitial and peri-adventitial spaces) depths of the tissue lesion formed by the absorption of ultrasonic energy and conduction of heat. Porcine studies have confirmed the safety (protected intimal and medial layers) and effectiveness (ablation of 1-6 mm region) of the system and provided near-field and far-field depth data to correlate with bench and computer simulation models. The safety and effectiveness of the Paradise System, developed through computer model, bench and in vivo studies, has been demonstrated in human clinical studies.

  12. Assessment of circumferential cracks in hypereutectic Al-Si clutch housings

    Directory of Open Access Journals (Sweden)

    M. Haghshenas

    2017-04-01

    Full Text Available As in situ natural composites with silicon phase acting as the reinforcing phase, Al-Si alloys are among most commonly used aluminum alloys in automotive applications (i.e. engine component. Silicon contributes to the strength of Al-Si alloys through load transfer from the Al matrix to the hard (rigid Si phase in the microstructure (load-carrying capacity. Casting parameters (i.e. solidification rate, elemental segregation, secondary dendrite spacing… as well as the size and distribution of the microstructural constituents in Al-Si alloys (i.e. morphology of Si particles, intermetallic compounds, secondary dendrite spacing contribute directly to the mechanical response and failure (or fracture behavior of the alloy within the service. In hyper-eutectic Al-Si alloys (i.e. B390.0, distribution of coarse pre-eutectic Si particle mainly contribute to stress concentration, crack initiation and propagation during the actual service condition. In the present paper, the parameters contribution to the formation of the circumferential cracks in clutch housings made of die cast hyper-eutectics B390.0 Al-Si alloys are assessed through optical microscopy and scanning electron microscopy. Casting variable, cooling rate, their effect on the cracks as well some of the possible causes are also discussed in detail.

  13. The use of technetium-99m hexamethylpropylene amine oxime labelled granulocytes with single-photon emission tomography imaging in the detection and follow-up of recurrence of infective endocarditis complicating transvenous endocardial pacemaker

    International Nuclear Information System (INIS)

    Ramackers, J.M.; Kotzki, P.O.; Couret, I.; Messner-Pellenc, P.; Davy, J.M.; Rossi, M.

    1995-01-01

    In this case report we present a patient with a recurrence of subacute bacterial infectious endocarditis (IE) complicating a transvenous endocardial pacemaker. Technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO) labelled granulocytes were used for diagnosis and follow-up under medical treatment only, since surgical removal of the pacemaker lead was ruled out because of the general condition of the patient. Single-photon emission tomography (SPET) imaging displayed the active lesion previously suspected on echography. At the end of antibiotic therapy, SPET indicated a favourable disease outcome whereas echocardiographic abnormalities remained nearly unchanged. The medical treatment had eradicated the IE, and the patient did well for more than 1 year thereafter. (orig.)

  14. The use of technetium-99m hexamethylpropylene amine oxime labelled granulocytes with single-photon emission tomography imaging in the detection and follow-up of recurrence of infective endocarditis complicating transvenous endocardial pacemaker

    Energy Technology Data Exchange (ETDEWEB)

    Ramackers, J M [Department of Nuclear Medicine, CHU E. Herriot, Lyon (France); Kotzki, P O [Department of Nuclear Medicine, CHU Lapeyronie et A. de Villeneuve, Montpellier (France); Couret, I [Department of Nuclear Medicine, CHU Lapeyronie et A. de Villeneuve, Montpellier (France); Messner-Pellenc, P [Department of Cardiology, CHU Lapeyronie et A. Villeneuve, Montpellier (France); Davy, J M [Department of Cardiology, CHU Lapeyronie et A. Villeneuve, Montpellier (France); Rossi, M [Department of Nuclear Medicine, CHU Lapeyronie et A. de Villeneuve, Montpellier (France)

    1995-11-01

    In this case report we present a patient with a recurrence of subacute bacterial infectious endocarditis (IE) complicating a transvenous endocardial pacemaker. Technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) labelled granulocytes were used for diagnosis and follow-up under medical treatment only, since surgical removal of the pacemaker lead was ruled out because of the general condition of the patient. Single-photon emission tomography (SPET) imaging displayed the active lesion previously suspected on echography. At the end of antibiotic therapy, SPET indicated a favourable disease outcome whereas echocardiographic abnormalities remained nearly unchanged. The medical treatment had eradicated the IE, and the patient did well for more than 1 year thereafter. (orig.)

  15. Myocardial Tbx20 regulates early atrioventricular canal formation and endocardial epithelial-mesenchymal transition via Bmp2.

    Science.gov (United States)

    Cai, Xiaoqiang; Nomura-Kitabayashi, Aya; Cai, Weibin; Yan, Jianyun; Christoffels, Vincent M; Cai, Chen-Leng

    2011-12-15

    During early embryogenesis, the formation of the cardiac atrioventricular canal (AVC) facilitates the transition of the heart from a linear tube into a chambered organ. However, the genetic pathways underlying this developmental process are poorly understood. The T-box transcription factor Tbx20 is expressed predominantly in the AVC of early heart tube. It was shown that Tbx20 activates Nmyc1 and suppresses Tbx2 expression to promote proliferation and specification of the atrial and ventricular chambers, yet it is not known if Tbx20 is involved in early AVC development. Here, we report that mice lacking Tbx20 in the AVC myocardium fail to form the AVC constriction, and the endocardial epithelial-mesenchymal transition (EMT) is severely perturbed. Tbx20 maintains expression of a variety of genes, including Bmp2, Tbx3 and Hand1 in the AVC myocardium. Intriguingly, we found Bmp2 downstream genes involved in the EMT initiation are also downregulated. In addition, re-expression of Bmp2 in the AVC myocardium substantially rescues the EMT defects resulting from the lack of Tbx20, suggesting Bmp2 is one of the key downstream targets of Tbx20 in AVC development. Our data support a complex signaling network with Tbx20 suppressing Tbx2 in the AVC myocardium but also indirectly promoting Tbx2 expression through Bmp2. The spatiotemporal expression of Tbx2 in the AVC appears to be balanced between these two opposing signals. Overall, our study provides genetic evidence that Tbx20 has essential roles in regulating AVC development that coordinate early cardiac chamber formation. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Local heart irradiation of ApoE−/− mice induces microvascular and endocardial damage and accelerates coronary atherosclerosis

    International Nuclear Information System (INIS)

    Gabriels, Karen; Hoving, Saske; Seemann, Ingar; Visser, Nils L.; Gijbels, Marion J.; Pol, Jeffrey F.; Daemen, Mat J.; Stewart, Fiona A.; Heeneman, Sylvia

    2012-01-01

    Background and purpose: Radiotherapy of thoracic and chest-wall tumors increases the long-term risk of radiation-induced heart disease, like a myocardial infarct. Cancer patients commonly have additional risk factors for cardiovascular disease, such as hypercholesterolemia. The goal of this study is to define the interaction of irradiation with such cardiovascular risk factors in radiation-induced damage to the heart and coronary arteries. Material and methods: Hypercholesterolemic and atherosclerosis-prone ApoE −/− mice received local heart irradiation with a single dose of 0, 2, 8 or 16 Gy. Histopathological changes, microvascular damage and functional alterations were assessed after 20 and 40 weeks. Results: Inflammatory cells were significantly increased in the left ventricular myocardium at 20 and 40 weeks after 8 and 16 Gy. Microvascular density decreased at both follow-up time-points after 8 and 16 Gy. Remaining vessels had decreased alkaline phosphatase activity (2–16 Gy) and increased von Willebrand Factor expression (16 Gy), indicative of endothelial cell damage. The endocardium was extensively damaged after 16 Gy, with foam cell accumulations at 20 weeks, and fibrosis and protein leakage at 40 weeks. Despite an accelerated coronary atherosclerotic lesion development at 20 weeks after 16 Gy, gated SPECT and ultrasound measurements showed only minor changes in functional cardiac parameters at 20 weeks. Conclusions: The combination of hypercholesterolemia and local cardiac irradiation induced an inflammatory response, microvascular and endocardial damage, and accelerated the development of coronary atherosclerosis. Despite these pronounced effects, cardiac function of ApoE −/− mice was maintained.

  17. Simplified method of calculating residual stress in circumferential welding of piping

    International Nuclear Information System (INIS)

    Umemoto, Tadahiro

    1984-01-01

    Many circumferential joints of piping are used in as-welded state, but in these welded joints, the residual stress as high as the yield stress of materials arises, and causes to accelerate stress corrosion cracking and corrosion fatigue. The experiment or the finite element method to clarify welding residual stress requires much time and labor, and is expensive, therefore, the author proposed the simplified method of calculation. The heating and cooling process of welding is very complex, and cannot be modeled as it is, therefore, it was assumed that in multiple layer welding, the welding condition of the last layer determines the residual stress, that material constants are invariable regardless of temperature, that the temperature distribution and residual stress are axisymmetric, and that there is repeated stress-strain relation in the vicinity of welded parts. The temperature distribution at the time of welding, thermal stress and welding residual stress are analyzed, and the material constants used for the calculation of residual stress are given. As the example of calculation, the effect of welding heat input and materials is shown. The extension of the method to a thick-walled pipe is discussed. (Kako, I.)

  18. PWR clad ballooning: The effect of circumferential clad temperature variations on the burst strain/burst temperature relationship

    International Nuclear Information System (INIS)

    Barlow, P.

    1983-01-01

    By experiment, it has been shown by other workers that there is a reduction in the creep ductility of Zircaloy 4 in the α+β phase transition region. Results from single rod burst tests also show a reduction in burst strain in the α+β phase region. In this report it is shown theoretically that for single rod burst tests in the presence of circumferential temperature gradients, the temperature dependence of the mean burst strain is not determined by temperature variations in creep ductility, but is governed by the temperature sensitivity of the creep strain rate, which is shown to be a maximum in the α+β phase transition region. To demonstrate this effect, the mean clad strain at burst was calculated for creep straining at different temperature levels in the α, α+β and β phase regions. Cross-pin temperature gradients were applied which produced strain variations around the clad which were greatest in the α+β phase region. The mean strain at burst was determined using a maximum local burst strain (i.e. a creep ductility) which is independent of temperature. By assuming cross-pin temperature gradients which are typical of those observed during burst tests, then the calculated mean burst strain/burst temperature relationship gave good agreement with experiment. The calculations also show that when circumferential temperature differences are present, the calculated mean strain at burst is not sensitive to variations in the magnitude of the assumed creep ductility. This reduces the importance of the assumed burst criterion in the calculations. Hence a temperature independent creep ductility (e.g. 100% local strain) is adequate as a burst criterion for calculations under PWR LOCA conditions. (author)

  19. Estimations of creep behavior and failure life for a circumferentially notched specimen

    International Nuclear Information System (INIS)

    Kobayashi, Ken-ichi; Yokobori, Toshimitsu; Kikuchi, Kenji.

    1997-01-01

    No method with which to characterize and/or illustrate total creep behavior for specimens with notches, holes or cracks has been proposed. In this paper it is proposed that most creep curves can be drawn with a master curve for each creep test whenever test conditions and failure modes are similar to each other, and the lifetime ratio normalized by the rupture time is introduced. Using smooth and circumferentially notched specimens of 2.25 Cr-1 Mo steel, creep tests were performed at 600degC for examination of this concept. Furthermore, a θ projection method was used to describe creep curves for notched specimens and to extrapolate longer creep lives. Then, the whole creep curve shape for notched specimens could be easily drawn, except for that in the vicinity of the rupture point. However, longer creep lives of notched specimens were underestimated in comparison with a simple extrapolation of the experimental data. This resulted from the negative dependence of the parameter of θ 3 on the applied stress. (author)

  20. Instability predictions for circumferentially cracked Type-304 stainless steel pipes under dynamic loading. Volume 2. Appendixes. Final report

    International Nuclear Information System (INIS)

    Zahoor, A.; Wilkowski, G.; Abou-Sayed, I.; Marschall, C.; Broek, D.; Sampath, S.; Rhee, H.; Ahmad, J.

    1982-04-01

    This report provides methods to predict margins of safety for circumferentially cracked Type 304 stainless steel pipes subjected to applied bending loads. An integrated combination of experimentation and analysis research was pursued. Two types of experiments were performed: (1) laboratory-scale tests on center-cracked panels and bend specimens to establish the basic mechanical and fracture properties of Type 304 stainless steel, and (2) full-scale pipe fracture tests under quasi-static and dynamic loadings to assess the analysis procedures. Analyses were based upon the simple plastic collapse criterion, a J-estimation procedure, and elastic-plastic large-deformation finite element models

  1. Detection of leak-defective fuel rods using the circumferential Lamb waves excited by the resonance backscattering of ultrasonic pulses

    International Nuclear Information System (INIS)

    Choi, M.S.; Yang, M.S.; Kim, H.C.

    1992-01-01

    A new ultrasonic technique for detecting the infiltrated water in leaked fuel rods is developed. Propagation characteristics of the circumferential Lamb waves in the cladding tubes are estimated by the resonance scattering theory. The Lamb waves are excited by the resonance backscattering of ultrasonic pulses. In sound fuel rods, the existence of the Lamb waves is revealed by a series of periodic echoes. In leaked fuel rods, however, the Lamb waves are perturbed strongly by the scattered waves from the surface of fuel pellets, thus the periodic echoes are not observed. (author)

  2. A Steel Ball Surface Quality Inspection Method Based on a Circumferential Eddy Current Array Sensor.

    Science.gov (United States)

    Zhang, Huayu; Xie, Fengqin; Cao, Maoyong; Zhong, Mingming

    2017-07-01

    To efficiently inspect surface defects on steel ball bearings, a new method based on a circumferential eddy current array (CECA) sensor was proposed here. The best probe configuration, in terms of the coil quality factor (Q-factor), magnetic field intensity, and induced eddy current density on the surface of a sample steel ball, was determined using 3-, 4-, 5-, and 6-coil probes, for analysis and comparison. The optimal lift-off from the measured steel ball, the number of probe coils, and the frequency of excitation current suitable for steel ball inspection were obtained. Using the resulting CECA sensor to inspect 46,126 steel balls showed a miss rate of ~0.02%. The sensor was inspected for surface defects as small as 0.05 mm in width and 0.1 mm in depth.

  3. Rectal cancer: involved circumferential resection margin - a root cause analysis.

    Science.gov (United States)

    Youssef, H; Collantes, E C; Rashid, S H; Wong, L S; Baragwanath, P

    2009-06-01

    An involved circumferential resection margin (CRM) following surgery for rectal cancer is the strongest predictor of local recurrence and may represent a failure of the multidisciplinary team (MDT) process. The study analyses the causes of positive CRM in patients undergoing elective surgery for rectal cancer with respect to the decision-making process of the MDT, preoperative rectal cancer staging and surgical technique. From March 2002 to September 2005, data were collected prospectively on all patients undergoing elective rectal cancer surgery with curative intent. The data on all patients identified with positive CRM were analysed. Of 158 patients (male:female = 2.2:1) who underwent potentially curative surgery, 16 (10%) patients had a positive CRM on postoperative histology. Four were due to failure of the pelvic magnetic resonance imaging (MRI) staging scans to predict an involved margin, two with an equivocal CRM on MRI did not have preoperative radiotherapy, one had an inaccurate assessment of the site of primary tumour and in one intra-operative difficulty was encountered. No failure of staging or surgery was identified in the remaining eight of the 16 patients. Abdominoperineal resection (APR) was associated with a 26% positive CRM, compared with 5% for anterior resection. No single consistent cause was found for a positive CRM. The current MDT process and/or surgical technique may be inadequate for low rectal tumours requiring APR.

  4. Lagrangian displacement tracking using a polar grid between endocardial and epicardial contours for cardiac strain imaging.

    Science.gov (United States)

    Ma, Chi; Varghese, Tomy

    2012-04-01

    Accurate cardiac deformation analysis for cardiac displacement and strain imaging over time requires Lagrangian description of deformation of myocardial tissue structures. Failure to couple the estimated displacement and strain information with the correct myocardial tissue structures will lead to erroneous result in the displacement and strain distribution over time. Lagrangian based tracking in this paper divides the tissue structure into a fixed number of pixels whose deformation is tracked over the cardiac cycle. An algorithm that utilizes a polar-grid generated between the estimated endocardial and epicardial contours for cardiac short axis images is proposed to ensure Lagrangian description of the pixels. Displacement estimates from consecutive radiofrequency frames were then mapped onto the polar grid to obtain a distribution of the actual displacement that is mapped to the polar grid over time. A finite element based canine heart model coupled with an ultrasound simulation program was used to verify this approach. Segmental analysis of the accumulated displacement and strain over a cardiac cycle demonstrate excellent agreement between the ideal result obtained directly from the finite element model and our Lagrangian approach to strain estimation. Traditional Eulerian based estimation results, on the other hand, show significant deviation from the ideal result. An in vivo comparison of the displacement and strain estimated using parasternal short axis views is also presented. Lagrangian displacement tracking using a polar grid provides accurate tracking of myocardial deformation demonstrated using both finite element and in vivo radiofrequency data acquired on a volunteer. In addition to the cardiac application, this approach can also be utilized for transverse scans of arteries, where a polar grid can be generated between the contours delineating the outer and inner wall of the vessels from the blood flowing though the vessel.

  5. The Influence of Hospital Volume on Circumferential Resection Margin Involvement: Results of the Dutch Surgical Colorectal Audit.

    Science.gov (United States)

    Gietelink, Lieke; Henneman, Daniel; van Leersum, Nicoline J; de Noo, Mirre; Manusama, Eric; Tanis, Pieter J; Tollenaar, Rob A E M; Wouters, Michel W J M

    2016-04-01

    This population-based study evaluates the association between hospital volume and CRM (circumferential resection margin) involvement, adjusted for other confounders, in rectal cancer surgery. A low hospital volume (risk of CRM involvement (odds ratio=1.54; 95% CI: 1.12-2.11). To evaluate the association between hospital volume and CRM (circumferential resection margin) involvement in rectal cancer surgery. To guarantee the quality of surgical treatment of rectal cancer, the Association of Surgeons of the Netherlands has stated a minimal annual volume standard of 20 procedures per hospital. The influence of hospital volume has been examined for different outcome variables in rectal cancer surgery. Its influence on the pathological outcome (CRM) however remains unclear. As long-term outcomes are best predicted by the CRM status, this parameter is of essential importance in the debate on the justification of minimal volume standards in rectal cancer surgery. Data from the Dutch Surgical Colorectal Audit (2011-2012) were used. Hospital volume was divided into 3 groups, and baseline characteristics were described. The influence of hospital volume on CRM involvement was analyzed, in a multivariate model, between low- and high-volume hospitals, according to the minimal volume standards. This study included 5161 patients. CRM was recorded in 86% of patients. CRM involvement was 11% in low-volume group versus 7.7% and 7.9% in the medium- and high-volume group (P≤0.001). After adjustment for relevant confounders, the influence of hospital volume on CRM involvement was still significant odds ratio (OR) = 1.54; 95% CI: 1.12-2.11). The outcomes of this pooled analysis support minimal volume standards in rectal cancer surgery. Low hospital volume was independently associated with a higher risk of CRM involvement (OR = 1.54; 95% CI: 1.12-2.11).

  6. Posterior transpedicular approach with circumferential debridement and anterior reconstruction as a salvage procedure for symptomatic failed vertebroplasty.

    Science.gov (United States)

    Chiu, Yen-Chun; Yang, Shih-Chieh; Chen, Hung-Shu; Kao, Yu-Hsien; Tu, Yuan-Kun

    2015-02-10

    Complications and failure of vertebroplasty, such as cement dislodgement, cement leakage, or spinal infection, usually result in spinal instability and neural element compression. Combined anterior and posterior approaches are the most common salvage procedure for symptomatic failed vertebroplasty. The purpose of this study is to evaluate the feasibility and efficacy of a single posterior approach technique for the treatment of patients with symptomatic failed vertebroplasty. Ten patients with symptomatic failed vertebroplasty underwent circumferential debridement and anterior reconstruction surgery through a single-stage posterior transpedicular approach (PTA) from January 2009 to December 2011 at our institution. The differences of visual analog scale (VAS), neurologic status, and vertebral body reconstruction before and after surgery were recorded. The clinical outcomes of patients were categorized as excellent, good, fair, or poor based on modified Brodsky's criteria. The symptomatic failed vertebroplasty occurred between the T11 and L3 vertebrae with one- or two-level involvement. The average VAS score was 8.3 (range, 7 to 9) before surgery, significantly decreased to 3.2 (range, 2 to 4) after surgery (p surgery was 17.3° (range, 4° to 35°) (p surgery was 1 mm (range, 0 to 2). The neurologic status of Frankel's scale significantly improved after surgery (p = 0.014) and at 1 year after surgery (p = 0.046). No one experienced severe complications such as deep wound infection or neurologic deterioration. All patients achieved good or excellent outcomes after surgery based on modified Brodsky's criteria (p surgery with circumferential debridement and anterior reconstruction technique provides good clinical outcomes and low complication rate, which can be considered as an alternative method to combined anterior and posterior approaches for patients with symptomatic failed vertebroplasty.

  7. Statistical and Graphical Assessment of Circumferential and Radial Hardness Variation of AISI 4140, AISI 1020 and AA 6082 Aluminum Alloy

    Directory of Open Access Journals (Sweden)

    Hamad Al-Khalid

    2011-12-01

    Full Text Available Hardness homogeneity of the commonly used structural ferrous and nonferrous engineering materials is of vital importance in the design stage, therefore, reliable information regarding material properties homogeneity should be validated and any deviation should be addressed. In the current study the hardness variation, over wide spectrum radial locations of some ferrous and nonferrous structural engineering materials, was investigated. Measurements were performed over both faces (cross-section of each stock bar according to a pre-specified stratified design, ensuring the coverage of the entire area both in radial and circumferential directions. Additionally the credibility of the apparatus and measuring procedures were examined through a statistically based calibration process of the hardness reference block. Statistical and response surface graphical analysis are used to examine the nature, adequacy and significance of the measured hardness values. Calibration of the apparatus reference block proved the reliability of the measuring system, where no strong evidence was found against the stochastic nature of hardness measures over the various stratified locations. Also, outlier elimination procedures were proved to be beneficial only at fewer measured points. Hardness measurements showed a dispersion domain that is within the acceptable confidence interval. For AISI 4140 and AISI 1020 steels, hardness is found to have a slight decrease trend as the diameter is reduced, while an opposite behavior is observed for AA 6082 aluminum alloy. However, no definite significant behavior was noticed regarding the effect of the sector sequence (circumferential direction.

  8. Failure behavior of a pipe system with a circumferentially orientated flaw - analytical and experimental investigations

    International Nuclear Information System (INIS)

    Mikkola, T.P.J.; Diem, H.; Blind, D.; Hunger, H.

    1989-01-01

    At the german HDR-test-facility a pipe failure experiment was performed at a fullsize feedwater piping system under operating conditions of T=240 0 C, p=10.6 MPa and with an elevated oxygen content in the pressure medium. The loading was internal pressure and a cyclic varying bending moment with an R-ratio of 0.5. The in form of a circumferentially orientated notch initially weakened piping system failed after a total number of 4773 loaded cycles with different frequencies in form of a small leak. The analyses of the fracture surface indicated the strongly growing influence of corrosion effects on the crack propagation rate with decreasing loading frequency. The cyclic crack growth and the leak-before-break behavior of the piping system could be explained on the basis of results of finite element calculations using ADINA-code. (orig.)

  9. A Steel Ball Surface Quality Inspection Method Based on a Circumferential Eddy Current Array Sensor

    Directory of Open Access Journals (Sweden)

    Huayu Zhang

    2017-07-01

    Full Text Available To efficiently inspect surface defects on steel ball bearings, a new method based on a circumferential eddy current array (CECA sensor was proposed here. The best probe configuration, in terms of the coil quality factor (Q-factor, magnetic field intensity, and induced eddy current density on the surface of a sample steel ball, was determined using 3-, 4-, 5-, and 6-coil probes, for analysis and comparison. The optimal lift-off from the measured steel ball, the number of probe coils, and the frequency of excitation current suitable for steel ball inspection were obtained. Using the resulting CECA sensor to inspect 46,126 steel balls showed a miss rate of ~0.02%. The sensor was inspected for surface defects as small as 0.05 mm in width and 0.1 mm in depth.

  10. Assessment of circumferential angle-closure by the iris-trabecular contact index with swept-source optical coherence tomography.

    Science.gov (United States)

    Baskaran, Mani; Ho, Sue-Wei; Tun, Tin A; How, Alicia C; Perera, Shamira A; Friedman, David S; Aung, Tin

    2013-11-01

    To evaluate the diagnostic performance of the iris-trabecular contact (ITC) index, a measure of the degree of angle-closure, using swept-source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan) in comparison with gonioscopy. Prospective observational study. A total of 108 normal subjects and 32 subjects with angle-closure. The SSOCT 3-dimensional angle scans, which obtain radial scans for the entire circumference of the angle, were performed under dark conditions and analyzed using customized software by a single examiner masked to the subjects' clinical details. The ITC index was calculated as a percentage of the angle that was closed on SSOCT images. First-order agreement coefficient (AC1) statistics and area under the receiver operating characteristic curve (AUC) analyses were performed for angle-closure on the basis of the ITC index in comparison with gonioscopy. Angle-closure on gonioscopy was defined as nonvisibility of posterior trabecular meshwork for at least 2 quadrants. Agreement of the ITC index with gonioscopically defined angle-closure was assessed using the AC1 statistic. Study subjects were predominantly Chinese (95.7%) and female (70.7%), with a mean age of 59.2 (standard deviation, 8.9) years. The median ITC index was 15.24% for gonioscopically open-angle eyes (n = 108) and 48.5% for closed-angle eyes (n = 32) (P = 0.0001). The agreement for angle-closure based on ITC index cutoffs (>35% and ≥50%) and gonioscopic angle-closure was 0.699 and 0.718, respectively. The AUC for angle-closure detection using the ITC index was 0.83 (95% confidence interval, 0.76-0.89), with an ITC index >35% having a sensitivity of 71.9% and specificity of 84.3%. The ITC index is a summary measure of the circumferential extent of angle-closure as imaged with SSOCT. The index had moderate agreement and good diagnostic performance for angle-closure with gonioscopy as the reference standard. Copyright © 2013 American Academy of

  11. Mis-Match Limit Load Analyses and Fracture Mechanics Assessment for Welded Pipe with Circumferential Crack at the Center of Weldment

    Energy Technology Data Exchange (ETDEWEB)

    Song, Tae Kwang; Jeon, Jun Young; Shim, Kwang Bo; Kim, Yun Jae [Korea University, Seoul (Korea, Republic of); Kim, Jong Sung [Sunchon University, Suncheon (Korea, Republic of); Jin, Tae Eun [Korea Power Engineering Company, Daejeon (Korea, Republic of)

    2010-01-15

    In this paper, limit load analyses and fracture mechanics analyses were conducted via finite element analyses for the welded pipe with circumferential crack at the center of the weldment. Systematic changes for strength mismatch ratio, width of weldment, crack shape and thickness ratio of the pipe were considered to provide strength mismatch limit load. And J-integral calculations based on reference stress method were conducted for two materials, stainless steel and ferritic steel. Reference stress defined by provided strength mis-match limit load gives much more accurate J-integral.

  12. Instability predictions for circumferentially cracked Type-304 stainless steel pipes under dynamic loading. Volume 2. Appendixes. Final report. [BWR

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.; Wilkowski, G.; Abou-Sayed, I.; Marschall, C.; Broek, D.; Sampath, S.; Rhee, H.; Ahmad, J.

    1982-04-01

    This report provides methods to predict margins of safety for circumferentially cracked Type 304 stainless steel pipes subjected to applied bending loads. An integrated combination of experimentation and analysis research was pursued. Two types of experiments were performed: (1) laboratory-scale tests on center-cracked panels and bend specimens to establish the basic mechanical and fracture properties of Type 304 stainless steel, and (2) full-scale pipe fracture tests under quasi-static and dynamic loadings to assess the analysis procedures. Analyses were based upon the simple plastic collapse criterion, a J-estimation procedure, and elastic-plastic large-deformation finite element models.

  13. Cut-off frequencies of circumferential horizontal shear waves in various functionally graded cylinder shells.

    Science.gov (United States)

    Shen, Xiaoqin; Ren, Dawei; Cao, Xiaoshan; Wang, Ji

    2018-03-01

    In this study, cut-off frequencies of the circumferential SH waves in functionally graded piezoelectric-piezomagnetic material (FGPPM) cylinder shells with traction free, electrical and magnetic open boundary conditions are investigated analytically. The Wentzel-Kramers-Brillouin (WKB) method is employed for solving differential equations with variable coefficients for general cases. For comparison, Bessel functions and Kummer functions are used for solving cut-off frequency problems in homogenous and ideal FGPPM cylinder shells. It is shown that the WKB solution for the cut-off frequencies has good precise. The set of cut-off frequencies is a series of approximate arithmetic progressions, for which the difference is a function of the density and the effective elastic parameter. The relationship between the difference and the gradient coefficient is described. These results provide theoretical guidance for the non-destructive evaluation of curved shells based on the cut-off frequencies. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Normal nonuniformity of left ventricular contraction. Assessment by cine MR imaging with presaturation myocardial tagging

    International Nuclear Information System (INIS)

    Naito, H.; Arisawa, J.; Harada, K.; Yamagami, H.; Kozuka, T.; Tamura, S.

    1996-01-01

    Purpose: To identify the normal performance of left ventricular (LV) regional contraction using cine MR imaging with presaturation myocardial tagging. Material and Methods: Sixteen normal volunteers were examined on a 1.5 T MR system with tagging cine sequences. Tags were applied at end-diastole as 2 parallel black lines on short-axis and 4-chamber sections, and the fractional shortenings were calculated at 7 LV locations. Results: The following results were obtained with significance: A transmural gradient of contractility in the short-axis section; prolonged late-systolic endocardial shortening and epicardial early termination in the free wall; initial delay of shortening in the anterior wall; apical predominance of contractility; predominance of circumferential shortening in the free wall and of meridional shortening in the septum. These findings could be associated with myocardial fiber architecture, presumed wall stress and temporal asynergy of excitation. Conclusion: Cine MR imaging with myocardial tagging proved to be useful in assessing the nonuniformity of LV contraction. (orig.)

  15. Global limit load solutions for thick-walled cylinders with circumferential cracks under combined internal pressure, axial force and bending moment − Part II: Finite element validation

    International Nuclear Information System (INIS)

    Li, Yuebing; Lei, Yuebao; Gao, Zengliang

    2014-01-01

    Global limit load solutions for thick-walled cylinders with circumferential internal/external surface and through-wall defects under combined positive/negative axial force, positive/negative global bending moment and internal pressure have been developed in Part I of this paper. In this Part II, elastic-perfectly plastic 3-D finite element (FE) analyses are performed for selected cases, covering a wide range of geometries and load combinations, to validate the developed limit load solutions. The results show that these limit load solutions can predict the FE data very well for the cases with shallow or deep and short cracks and are conservative. For the cases with very long and deep cracks, the predictions are reasonably accurate and more conservative. -- Highlights: • Elastic-perfectly plastic 3D finite element limiting analyses of cylinders. • Thin/thick-walled cylinders with circumferential surface defects. • Combined loading for pressure, end-force and global bending moment. • Totally 1458 cases analysed and tabulated normalised results provided. • Results used to validate the developed limit load solutions in Part I of this paper

  16. The stability of growth of a through-wall circumferential crack in a cylindrical pipe subjected to bending deformation

    International Nuclear Information System (INIS)

    Smith, E.

    1987-01-01

    Tada, Paris and Gamble have used the tearing modulus approach to examine the stability of growth of a through-wall circumferential crack in a 304 stainless steel circular cylindrical pipe subject to bending deformation. They showed that crack growth is stable, in the sense that growth requires the rotation imposed at the pipe-ends to be increased, provided the pipe length is less than a critical length Lsub(c), which is given by their analysis. The Tada-Paris-Gamble analysis focuses on the question of the stability, or otherwise, of crack growth at the onset of crack extension. The analysis does not consider the possibilities that (a) instability might occur after some stable crack growth, and (b) arrest might occur after some unstable growth. A study of these aspects of the circumferential crack growth problem using the tearing modulus approach is precluded by the geometry dependence of the J-crack growth resistance curve. Consequently the present paper uses a crack tip opening angle criterion to describe crack growth, and thereby demonstrates that possibilities (a) and (b) should both occur, depending on the initial crack length and pipe length. In terms of relevance to the technologically important problem of cracking in Boiling Water Reactor piping, the important conclusion stemming from the paper's analysis is that stability of crack growth after the onset of crack extension is assured if the pipe length is less than a critical length L'sub(c). L'sub(c) is less than Lsub(c), the critical length relevant to the onset of crack extension, but it is still appreciably greater than the pipe run lengths in actual reactor piping systems, and safety against guillotine failure of a pipe is therefore generally assured. (author)

  17. Computerized Cuff Pressure Algometry as Guidance for Circumferential Tissue Compression for Wearable Soft Robotic Applications: A Systematic Review.

    Science.gov (United States)

    Kermavnar, Tjaša; Power, Valerie; de Eyto, Adam; O'Sullivan, Leonard W

    2018-02-01

    In this article, we review the literature on quantitative sensory testing of deep somatic pain by means of computerized cuff pressure algometry (CPA) in search of pressure-related safety guidelines for wearable soft exoskeleton and robotics design. Most pressure-related safety thresholds to date are based on interface pressures and skin perfusion, although clinical research suggests the deep somatic tissues to be the most sensitive to excessive loading. With CPA, pain is induced in deeper layers of soft tissue at the limbs. The results indicate that circumferential compression leads to discomfort at ∼16-34 kPa, becomes painful at ∼20-27 kPa, and can become unbearable even below 40 kPa.

  18. Enhancement of J estimation for typical nuclear pipes with a circumferential surface crack under tensile load

    International Nuclear Information System (INIS)

    Cho, Doo Ho; Woo, Seung Wan; Choi, Jae Boong; Kim, Young Jin; Chang, Yoon Suk; Jhung, Myung Jo; Choi, Young Hwan

    2010-01-01

    This paper is to report enhancement of engineering J estimation for semi-elliptical surface cracks under tensile load. Firstly, limitation of the sole solution suggested by Zahoor is shown for reliable structural integrity assessment of thin-walled nuclear pipes. An improved solution is then developed based on extensive 3D FE analyses employing deformation plasticity theory for typical nuclear piping materials. It takes over the structure of the existing solution but provides new tabulated plastic influence functions to cover a wide range of pipe geometry and crack shape. Furthermore, to facilitate easy prediction of the plastic influence function, an alternative simple equation is also developed by using a statistical response surface method. The proposed H 1 values can be used for elastic-plastic fracture analyses of thin-walled pipes with a circumferential surface crack subjected to tensile loading

  19. Enhancement of J estimation for typical nuclear pipes with a circumferential surface crack under tensile load

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Doo Ho; Woo, Seung Wan; Choi, Jae Boong; Kim, Young Jin [Sungkyunkwan University, Suwon (Korea, Republic of); Chang, Yoon Suk [Kyung Hee University, Yongin (Korea, Republic of); Jhung, Myung Jo; Choi, Young Hwan [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2010-03-15

    This paper is to report enhancement of engineering J estimation for semi-elliptical surface cracks under tensile load. Firstly, limitation of the sole solution suggested by Zahoor is shown for reliable structural integrity assessment of thin-walled nuclear pipes. An improved solution is then developed based on extensive 3D FE analyses employing deformation plasticity theory for typical nuclear piping materials. It takes over the structure of the existing solution but provides new tabulated plastic influence functions to cover a wide range of pipe geometry and crack shape. Furthermore, to facilitate easy prediction of the plastic influence function, an alternative simple equation is also developed by using a statistical response surface method. The proposed H{sub 1} values can be used for elastic-plastic fracture analyses of thin-walled pipes with a circumferential surface crack subjected to tensile loading

  20. Positioning means for circumferentially locating inspection apparatus in a nuclear reactor vessel

    International Nuclear Information System (INIS)

    Burns, D.C.

    1980-01-01

    There is provided for a reactor vessel inspection device a support ring sized to accommodate the circular path defined by three or more guide studs extending upwardly from the vessel. The support ring has at least three movably mounted guide stud bushings which can be positionally adjusted to align each bushing with one of the studs. When engaged, the guide studs and bushings yield a coarse positioning of the inspection device relative to the reactor vessel. Also provided are three support legs which are clamped to the support ring and dimensioned to an appropriate length. Two of the support legs have shoes clamped thereto, configured to rest on an internal circumferential flange within the reactor vessel. The third support leg is provided with a specially adapted shoe configured to engage a locating element, the exact position of which is known, within the vessel to achieve fine positioning of the inspection device relative to the reactor vessel. The support ring is additionally provided with an annular key which runs longitudinally about its outer periphery. Clamping means utilized to secure the guide stud bushings and the support legs to the support ring are provided with keyways to insure automatic self-alignment when fully tightened. (auth)

  1. Cell lineage patterns in the shoot meristem of the sunflower embryo in the dry seed

    International Nuclear Information System (INIS)

    Jegla, D.E.; Sussex, I.M.

    1989-01-01

    We mapped the fate of cells in the shoot meristem of the dry-seed embryo of sunflower, Helianthus annuus L. cv. Peredovic, using irradiation-induced somatic sectors. We analyzed 249 chlorophyll-deficient or glabrous (hairless) sectors generated in 236 plants. Most sectors observed in the inflorescence extended into vegetative nodes. Thus cell lineages that ultimately gave rise to reproductive structures also contributed to vegetative structures. No single sector extended the entire length of the shoot. Thus the shoot is not derived from one or a few apical initials. Rather, the position, vertical extent, and width of the sectors at different levels of the shoot suggest that the shoot is derived from three to four circumferential populations of cells in each of three cell layers of the embryo meristem. Sectors had no common boundaries even in plants with two or three independent sectors, but varied in extent and overlapped along the length of the shoot. Thus individual cells in a single circumferential population behaved independently to contribute lineages of different vertical extents to the growing shoot. The predicted number of circumferential populations of cells as well as the apparent cell number in each population was consistent with the actual number of cells in the embryo meristem observed in histological sections

  2. Plastic Limit Loads for Slanted Circumferential Through-Wall Cracked Pipes Using 3D Finite-Element Limit Analyses

    International Nuclear Information System (INIS)

    Jang, Hyun Min; Cho, Doo Ho; Kim, Young Jin; Huh, Nam Su; Shim, Do Jun; Choi, Young Hwan; Park, Jung Soon

    2011-01-01

    On the basis of detailed 3D finite-element (FE) limit analyses, the plastic limit load solutions for pipes with slanted circumferential through-wall cracks (TWCs) subjected to axial tension, global bending, and internal pressure are reported. The FE model and analysis procedure employed in the present numerical study were validated by comparing the present FE results with existing solutions for plastic limit loads of pipes with idealized TWCs. For the quantification of the effect of slanted crack on plastic limit load, slant correction factors for calculating the plastic limit loads of pipes with slanted TWCs from pipes with idealized TWCs are newly proposed from extensive 3D FE calculations. These slant-correction factors are presented in tabulated form for practical ranges of geometry and for each set of loading conditions

  3. Anastomosis in the absence of a suprahyoid release following circumferential sleeve resection is feasible in differentiated thyroid carcinoma patients with tracheal invasion.

    Science.gov (United States)

    Chen, Wanjun; Zou, Shujuan; Wang, Liang; Wu, Changhua; Wang, Zhiqi; Li, Ke; Zhang, Shuguang

    2017-09-01

    Invasion of the trachea is observed in ~6% of patients with differentiated thyroid carcinoma (DTC), and surgery is accepted as the treatment of choice. However, surgical procedures can be challenging and are associated with various risks. The authors of the present study performed a retrospective study of patients with DTC and tumor invasion of the trachea. Outcomes from patients that received circumferential sleeve resection (CSR) of the trachea followed by anastomosis in the absence of suprahyoid release (n=21; CSR group) and patients that underwent tangential resections [n=103; tangential 'shave' resection (TSR) group) were analyzed. In the CSR group, 4 to 8 tracheal rings were circumferentially resected. All patients underwent end-to-end anastomosis in the absence of suprahyoid release following CSR, and 7 patients developed cancer metastasis following surgery. With the exception of 2 patients that succumbed to disease, the remaining patients in the CSR group survived without cancer recurrence. In the TSR group, all of the patients experienced cancer recurrence within five years post-surgery. A total of 61 patients developed metastases in the three years following surgery, and 71 patients succumbed to cancer metastasis within five years. The survival rate of the CSR group was significantly increased compared with the TSR group. The results of the present study suggest that in DTC patients with defects involving up to 8 tracheal rings, it may be appropriate to perform anastomosis without suprahyoid tissue release as it is associated with a reduced incidence of perioperative morbidity.

  4. Circumferential lesion formation around the pulmonary veins in the left atrium with focused ultrasound using a 2D-array endoesophageal device: a numerical study

    Energy Technology Data Exchange (ETDEWEB)

    Pichardo, Samuel; Hynynen, Kullervo [Imaging Research-Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, Room C713, Toronto, ON M4N 3M5 (Canada)

    2007-08-21

    Atrial fibrillation (AF) is the most frequently sustained cardiac arrhythmia affecting humans. The electrical isolation by ablation of the pulmonary veins (PVs) in the left atrium (LA) of the heart has been proven as an effective cure of AF. The ablation consists mainly in the formation of a localized circumferential thermal coagulation of the cardiac tissue surrounding the PVs. In the present numerical study, the feasibility of producing the required circumferential lesion with an endoesophageal ultrasound probe is investigated. The probe operates at 1 MHz and consists of a 2D array with enough elements (114 x 20) to steer the acoustic field electronically in a volume comparable to the LA. Realistic anatomical conditions of the thorax were considered from the segmentation of histological images of the thorax. The cardiac muscle and the blood-filled cavities in the heart were identified and considered in the sound propagation and thermal models. The influence of different conditions of the thermal sinking in the LA chamber was also studied. The circumferential ablation of the PVs was achieved by the sum of individual lesions induced with the proposed device. Different scenarios of lesion formation were considered where ultrasound exposures (1, 2, 5 and 10 s) were combined with maximal peak temperatures (60, 70 and 80 {sup 0}C). The results of this numerical study allowed identifying the limits and best conditions for controlled lesion formation in the LA using the proposed device. A controlled situation for the lesion formation surrounding the PVs was obtained when the targets were located within a distance from the device in the range of 26 {+-} 7 mm. When combined with a maximal temperature of 70 {sup 0}C and an exposure time between 5 and 10 s, this distance ensured preservation of the esophageal structures, controlled lesion formation and delivery of an acoustic intensity at the transducer surface that is compatible with existing materials. With a peak

  5. Influence of circumferential flaw length on internal burst pressure of a wall-thinned pipe

    Energy Technology Data Exchange (ETDEWEB)

    Tsuji, Masataka, E-mail: tsuji-m@u-fukui.ac.jp [Graduate School of Engineering, University of Fukui, 3-9-1 Bunkyo, Fukui, Fukui (Japan); Meshii, Toshiyuki [Graduate School of Engineering, University of Fukui, 3-9-1 Bunkyo, Fukui, Fukui (Japan)

    2013-02-15

    Highlights: ► The effect of θ on p{sub f} was examined by experimental analysis and FEA. ► Here θ is the circumferential angle of a flaw, p{sub f} is the internal burst pressure. ► p{sub f} decreased as θ increased in some cases. ► The effect of θ on p{sub f} should be taken into consideration in evaluating p{sub f}. -- Abstract: This paper examines the effect of the circumferential angle of a flaw θ on the internal burst pressure p{sub f} of pipes with artificial wall-thinned flaws. The effect of θ has conventionally been regarded as unimportant in the evaluation of the p{sub f} of wall-thinned straight pipes. Therefore, a burst pressure equation for an axial crack inside a cylinder (Fig. 1, left), such as Kiefner's equation (Kiefner et al., 1973), has been widely applied (ANSI/ASME B31.G., 1991; Hasegawa et al., 2011). However, the following implicit assumptions notably exist when applying the equation to planar flaws in situations with non-planar flaws. 1)The fracture mode of the non-planar flaw under consideration is identical to that of the crack. 2)The effect of θ on p{sub f}, which is not considered for an axial crack, is small or negligible. However, the experimental results from the systematic burst tests for carbon steel pipes with artificial wall-thinned flaws examined in this paper showed that these implicit assumptions may be incorrect. In this paper the experimental results are evaluated in further detail. The purpose of the evaluation was to clarify the effect of θ on p{sub f}. Specifically, the significance of the flaw configuration (axial length δ{sub z} and wall-thinning ratio t{sub 1}/t) was studied for its effects on θ and p{sub f}. In addition, a simulation of this effect was conducted using a large strain elastic-plastic Finite Element Analysis (FEA) model. As observed from the experimental results, θ tended to affect p{sub f} in cases with large δ{sub z}, and t{sub 1}/t was also correlated with a decrease in p{sub f

  6. Crack tip field in circumferentially-cracked round bar (CCRB in tension affected by loss of axial symmetry

    Directory of Open Access Journals (Sweden)

    J. Toribio

    2017-07-01

    Full Text Available In this paper, the stress intensity factor (SIF is computed in a circumferentially-cracked round bar (CCRB subjected to tensile loading, considering that the resistant ligament is circular and exhibits certain eccentricity in relation to the cylinder axis. The computation was performed by means of the finite element method (FEM using a three dimensional (3D model and the J-integral, the analyzed variable being the eccentricity of the circular ligament. Results show that the SIF is higher at the deepest point of the crack and that an increase of eccentricity (in relation to the bar axis raises the difference between the SIF values along the crack front. From a certain value of the misalignment a bending effect appears, so that the crack remains closed in the area near the point of lower depth.

  7. Assessment of Myocardial Contractile Function Using Global and Segmental Circumferential Strain following Intracoronary Stem Cell Infusion after Myocardial Infarction: MRI Feature Tracking Feasibility Study

    International Nuclear Information System (INIS)

    Bhatti, Sabha; Al-Khalidi, Hussein; Hor, Kan; Hakeem, Abdul; Taylor, Michael; Quyyumi, Arshed A.; Oshinski, John; Pecora, Andrew L.; Kereiakes, Dean; Chung, Eugene; Pedrizzetti, Gianni; Miszalski-Jamka, Tomasz; Mazur, Wojciech

    2012-01-01

    Background. Magnetic resonance imaging (MRI) strain analysis is a sensitive method to assess myocardial function. Our objective was to define the feasibility of MRI circumferential strain (ε cc ) analysis in assessing subtle changes in myocardial function following stem cell therapy. Methods and Results. Patients in the Amorcyte Phase I trial were randomly assigned to treatment with either autologous bone-marrow-derived stem cells infused into the infarct-related artery 5 to 11 days following primary PCI or control. MRI studies were obtained at baseline, 3, and 6 months. ε cc was measured in the short axis views at the base, mid and apical slices of the left ventricle (LV) for each patient (13 treatments and 10 controls). Mid-anterior LV ε cc improved between baseline −18.5 ± 8.6 and 3 months −22.6 ± 7.0, P = 0.03. There were no significant changes in ε cc at 3 months and 6 months compared to baseline for other segments. There was excellent intraobserver and interobserver agreement for basal and mid circumferential strain. Conclusion. MRI segmental strain analysis is feasible in assessment of regional myocardial function following cell therapy with excellent intra- and inter-observer variability's. Using this method, a modest interval change in segmental ε cc was detected in treatment group

  8. Optimization of Reinforced Concrete Reservoir with Circumferential Stiffeners Strips by Particle Swarm Algorithm

    Directory of Open Access Journals (Sweden)

    GholamReza Havaei

    2015-09-01

    Full Text Available Reinforced concrete reservoirs (RCR have been used extensively in municipal and industrial facilities for several decades. The design of these structures requires that attention be given not only to strength requirements, but to serviceability requirements as well. These types of structures will be square, round, and oval reinforced concrete structures which may be above, below, or partially below ground. The main challenge is to design concrete liquid containing structures which will resist the extremes of seasonal temperature changes, a variety of loading conditions, and remain liquid tight for useful life of 50 to 60 years. In this study, optimization is performed by particle swarm algorithm basd on structural design. Firstly by structural analysis all range of shell thickness and areas of rebar find. In the second step by parameter identification system interchange algorithm, source code which developed in particle swarm algorithm by MATLAB software linked to analysis software. Therefore best and optimized thicknesses and total area of bars for each element find. Lastly with circumferential stiffeners structure optimize and show 19% decrease in weight of rebar, 20% decrease in volume of concrete, and 13% minimum cost reduction in construction procedure compared with conventional 10,000 m3 RCR structures.

  9. Parametric Study of Defect Detection in Pipes with Bend Using Guided Ultrasonic Waves

    Directory of Open Access Journals (Sweden)

    Jack Tan Jin

    2016-01-01

    Full Text Available The propagation behaviour of guided ultrasonic waves in a steel pipe with welded bend is studied by finite element simulation. The effectiveness of the longitudinal L(0,2 and torsional T(0,1 guided waves in detecting circumferential cut near the weld is investigated. In order to identify the presence of the defect, the reflection strength due to the cut is studied. The geometry of the weld is constructed based on common V-bevel butt joints and the anisotropy of the 316L stainless steel weld is included to correctly predict the scattering of ultrasonic waves. The finite element model is built to allow high accuracy. Detection of small circumferential cut (up to 60° circumferential extent can be achieved with longitudinal L(0,2 mode. Detection of moderate to large circumferential cut can be achieved by torsional T(0,1 or longitudinal L(0,2 modes, with T(0,1 mode preferred due to its less mode conversion to higher order modes.

  10. Development of a J-estimation scheme for internal circumferential and axial surface cracks in elbows

    International Nuclear Information System (INIS)

    Mohan, R.; Brust, F.W.; Ghadiali, N.; Wilkowski, G.

    1996-06-01

    This report summarizes efforts to develop elastic and elastic-plastic fracture mechanics analyses for internal surface cracks in elbows. The analyses involved development of a GE/EPRI type J-estimation scheme which requires an elastic and fully plastic contribution to crack-driving force in terms of the J-integral parameter. The elastic analyses require the development of F-function values to relate the J e term to applied loads. Similarly, the fully plastic analyses require the development of h-functions to relate the J p term to the applied loads. The F- and h-functions were determined from a matrix of finite element analyses. To minimize the cost of the analyses, three-dimensional ABAQUS finite element analyses were compared to a simpler finite element technique called the line-spring method. The line-spring method provides a significant computational savings over the full three-dimensional analysis. The comparison showed excellent agreement between the line-spring and three-dimensional analysis. This experience was consistent with comparisons with circumferential surface-crack analyses in straight pipes during the NRC's Short Cracks in Piping and Piping Welds program

  11. Ultrasonic phased array examination of circumferential weld joint in reactor pressure vessel of BWR

    Energy Technology Data Exchange (ETDEWEB)

    Nanekar, Paritosh, E-mail: pnanekar@barc.gov.in [Quality Assurance Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Jothilakshmi, N. [Quality Assurance Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Jayakumar, T. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    2013-12-15

    Highlights: • Phased array technique developed for weld joint inspection in BWR pressure vessel. • Simulation studies were carried out for conventional and phased array probe. • Conventional ultrasonic test shows in-adequate weld coverage and poor resolution. • Focused sound beam in phased array results in good resolution and sensitivity. • Ultrasonic phased array technique is validated on mock-up with reference defects. - Abstract: The weld joints in the reactor pressure vessel (RPV) of Boiling Water Reactors (BWR) are required to be examined periodically for assurance of structural integrity. Ultrasonic phased array examination technique has been developed in authors’ laboratory for inspection of the top flange to shell circumferential weld joint in RPV of BWRs, which are in operation in India since the late 1960s. The development involved detailed simulation studies for computation of focal laws followed by validation on mock-up. The paper brings out the limitations of the conventional ultrasonic technique and how this can be overcome by the phased array approach for the weld joint under consideration. The phased array technique was successfully employed for field examination of this weld joint in RPV during the re-fuelling outage.

  12. Circumferential tensile test method for mechanical property evaluation of SiC/SiC tube

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ju-Hyeon, E-mail: 15096018@mmm.muroran-it.ac.jp [Graduate School, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan); Kishimoto, Hirotatsu [Graduate School, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan); OASIS, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan); Park, Joon-soo [OASIS, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan); Nakazato, Naofumi [Graduate School, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan); Kohyama, Akira [OASIS, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan)

    2016-11-01

    Highlights: • NITE SiC/SiC cooling channel system to be a candidate of divertor system in future. • Hoop strength is one of the important factors for a tube. • This research studies the relationship between deformation and strain of SiC/SiC tube. - Abstract: SiC fiber reinforced/SiC matrix (SiC/SiC) composite is expected to be a candidate material for the first-wall, components in the blanket and divertor of fusion reactors in future. In such components, SiC/SiC composites need to be formed to be various shapes. SiC/SiC tubes has been expected to be employed for blanket and divertor after DEMO reactor, but there is not established mechanical investigation technique. Recent progress of SiC/SiC processing techniques is likely to realize strong, having gas tightness SiC/SiC tubes which will contribute for the development of fusion reactors. This research studies the relationship between deformation and strain of SiC/SiC tube using a circumferential tensile test method to establish a mechanical property investigation method of SiC/SiC tubes.

  13. 27 CFR 4.2 - Territorial extent.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Territorial extent. 4.2 Section 4.2 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LABELING AND ADVERTISING OF WINE Scope § 4.2 Territorial extent. This part...

  14. Marcapasso endocárdico definitivo na primeira década de vida Permanent endocardial pacemaker in the first decade of life

    Directory of Open Access Journals (Sweden)

    Roberto Costa

    1986-12-01

    ão necessita outros tipos de prótese para acomodar o eletrodo; 3 permite o acompanhamento seguro da criança com simples estudo radiológico; 4 preserva o sistema cava superior para a utilização na idade adulta; 5 permite, ainda, a integração social perfeita da criança, que poderá participar de atividades esportiva e de lazer, sem que o marcapasso seja notado pelas outras crianças.Pacemaker implantation in children represents a challenge due to the lack of flexibility of the existing system in relation to the growth of the patients to difficulties in choosing the best place to insert the pulse generator and to technical and social problems as well. Even in Services where the first option should have been the endocardial via, the epicardial implantation has been employed in low weight children. At the INCOR - USP, from November 1980 to October 1985, there were 21 endocardial pacemaker implantations in children at the first decade of their lives. The implantation technique consists of lead insertion through the femoral vein, leaving a loop in the right atrium and placing of the pulse generator in the illiac region. After few years, when the growth of the patient has stretched the lead, the child is reoperated to liberate more leak and to form a new loop, thus allowing the use of the same system for a very long period. The age of the patients varied from 2 months to 10 years. Thirteen of the 21 children were less than 5 years old, and 5 were in their first year of life. The predominant indication was 3rd. degree A-V block (90%, which in 75% of the cases was postoperative. In the follow-up period - three to 63 months and mean of 26 months - 3 patients died from causes unrelated to the pacemaker; the remaining patientsare well. Five children have been reoperated on to liberate the lead from the pulse generator pocket and to form a new loop in the atrium. The advantages of this technique were observed in the follow-up, as compared to epicardial and conventional endocardial

  15. Structural integrity of whipping pipes following a postulated circumferential break - a contribution to determining strain levels acceptable under faulted conditions

    International Nuclear Information System (INIS)

    Charalambus, B.; Labes, M.

    1993-01-01

    It is postulated that a break of a thin-walled pipe does not cause a subsequent break in the pipe in the vicinity of a plastic hinge even when the wall is weakened by a 60 circumferential crack of a depth of 30% of the wall thickness on the tension side. This pipe behavior is the result of plastic buckling in the compression side and applies to pipes of diameter-to-thickness ratio larger than 20. For this type of pipe, the axial strains decrease with increasing diameter-to-thickness ratio in the tension side. As the pipe is only loaded in one direction, there is no cyclic behavior that can trigger a subsequent break. (orig.)

  16. Integrated Assessment of Left Ventricular Electrical Activation and Myocardial Strain Mapping in Heart Failure Patients: A Holistic Diagnostic Approach for Endocardial Cardiac Resynchronization Therapy, Ablation of Ventricular Tachycardia, and Biological Therapy.

    Science.gov (United States)

    Maffessanti, Francesco; Prinzen, Frits W; Conte, Giulio; Regoli, François; Caputo, Maria Luce; Suerder, Daniel; Moccetti, Tiziano; Faletra, Francesco; Krause, Rolf; Auricchio, Angelo

    2018-01-01

    This study sought to test the accuracy of strain measurements based on anatomo-electromechanical mapping (AEMM) measurements compared with magnetic resonance imaging (MRI) tagging, to evaluate the diagnostic value of AEMM-based strain measurements in the assessment of myocardial viability, and the additional value of AEMM over peak-to-peak local voltages. The in vivo identification of viable tissue, evaluation of mechanical contraction, and simultaneous left ventricular activation is currently achieved using multiple complementary techniques. In 33 patients, AEMM maps (NOGA XP, Biologic Delivery Systems, Division of Biosense Webster, a Johnson & Johnson Company, Irwindale, California) and MRI images (Siemens 3T, Siemens Healthcare, Erlangen, Germany) were obtained within 1 month. MRI tagging was used to determine circumferential strain (E cc ) and delayed enhancement to obtain local scar extent (%). Custom software was used to measure E cc and local area strain (LAS) from the motion field of the AEMM catheter tip. Intertechnique agreement for E cc was good (R 2  = 0.80), with nonsignificant bias (0.01 strain units) and narrow limits of agreement (-0.03 to 0.06). Scar segments showed lower absolute strain amplitudes compared with nonscar segments: E cc (median [first to third quartile]: nonscar -0.10 [-0.15 to -0.06] vs. scar -0.04 [-0.06 to -0.02]) and LAS (-0.20 [-0.27 to -0.14] vs. -0.09 [-0.14 to -0.06]). AEMM strains accurately discriminated between scar and nonscar segments, in particular LAS (area under the curve: 0.84, accuracy = 0.76), which was superior to peak-to-peak voltages (nonscar 9.5 [6.5 to 13.3] mV vs. scar 5.6 [3.4 to 8.3] mV; area under the curve: 0.75). Combination of LAS and peak-to-peak voltages resulted in 86% accuracy. An integrated AEMM approach can accurately determine local deformation and correlates with the scar extent. This approach has potential immediate application in the diagnosis, delivery of intracardiac therapies, and their

  17. Global Bi-ventricular endocardial distribution of activation rate during long duration ventricular fibrillation in normal and heart failure canines.

    Science.gov (United States)

    Luo, Qingzhi; Jin, Qi; Zhang, Ning; Han, Yanxin; Wang, Yilong; Huang, Shangwei; Lin, Changjian; Ling, Tianyou; Chen, Kang; Pan, Wenqi; Wu, Liqun

    2017-04-13

    The objective of this study was to detect differences in the distribution of the left and right ventricle (LV & RV) activation rate (AR) during short-duration ventricular fibrillation (SDVF, 1 min) in normal and heart failure (HF) canine hearts. Ventricular fibrillation (VF) was electrically induced in six healthy dogs (control group) and six dogs with right ventricular pacing-induced congestive HF (HF group). Two 64-electrode basket catheters deployed in the LV and RV were used for global endocardium electrical mapping. The AR of VF was estimated by fast Fourier transform analysis from each electrode. In the control group, the LV was activated faster than the RV in the first 20 s, after which there was no detectable difference in the AR between them. When analyzing the distribution of the AR within the bi-ventricles at 3 min of LDVF, the posterior LV was activated fastest, while the anterior was slowest. In the HF group, a detectable AR gradient existed between the two ventricles within 3 min of VF, with the LV activating more quickly than the RV. When analyzing the distribution of the AR within the bi-ventricles at 3 min of LDVF, the septum of the LV was activated fastest, while the anterior was activated slowest. A global bi-ventricular endocardial AR gradient existed within the first 20 s of VF but disappeared in the LDVF in healthy hearts. However, the AR gradient was always observed in both SDVF and LDVF in HF hearts. The findings of this study suggest that LDVF in HF hearts can be maintained differently from normal hearts, which accordingly should lead to the development of different management strategies for LDVF resuscitation.

  18. Quantification of the extent and severity of myocardial ischemia in single-vessel disease using stress-redistribution thallium-201 single-photon emission computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Prigent, F.; Maddahi, J.; Garcia, E.; VanTrain, K.; Friedman, J.; Bietendorf, J.; Swan, H.J.C.; Waxman, A.; Berman, D.

    1984-01-01

    Single-vessel coronary artery (CA) disease (SVD) is not uniformly benign: long-term prognosis is likely to be related to the extent (E) and severity (S) of myocardial ischemia (isch). To assess the ability of stress thalium-201 (Tl) single photon emission computerized tomography (SPECT) to quantify E and S of isch, the authors studied 15 patients (pts) without myocardial infarction who had SVD (8 LAD, 4 RCA, and 3 LCX). SPECT cuts were analyzed using maximum count circumferential profiles (CPs) which were compared with previously established normal (nl) limits derived from 20 nl pts. E of isch was defined as the % of the CP points falling below nl, S and depth (D) of ischemia respectively expressed the total and the mean % by which the abnormal points fell below normal limits. Although all pts had SVD, the range of E, S and D of isch was wide (0 to 48% and 0 to 38% and 0 to 20% respectively). CA scores (CS) were derived using a 15-point system accounting for the distribution of the diseased CA, location, and degree of stenosis, and collateral supply. CS varied from 1.2 to 8. E and S significantly correlated with CS (r=.74,p=.001, and r=.78, p=.000, respectively). The 6 pts with a D less than or equal to .1 had 75% CA stenosis whereas 5 of the 9 pts with D <.1 had only 50-75% stenosis. Thus, the authors conclude that: 1) pts with SVD have highly differing degrees of isch; 2) E, S and D scores from Tl SPECT correlate favorably with the angiographic extent and severity of disease; and 3) SPECT offers potential for quantification of the magnitude of isch and may become a useful, noninvasive prognostic indicator.

  19. 球笼式等速万向节圆周间隙分析%Analysis on Circumferential Clearance of Rzeppa Constant Velocity Joint

    Institute of Scientific and Technical Information of China (English)

    黄钟灵; 郭常宁; 石宝枢

    2011-01-01

    针对球笼式等速万向节的结构与运动形式,建立了椭圆沟道截面圆周间隙的空间立体模型,推导了圆周间隙角θ在任意摆角和转角条件下的计算公式,使用Matlab软件研究了θ随摆角和转角变化的规律.结果表明:θ与椭圆沟道长、短半轴、钢球半径、钢球回转半径、偏心距、摆角以及转角有关,θ的6次波动是导致汽车行驶过程中振动和噪声的主要原因.%Based on structure and motion forms of rzeppa constant velocity joint,the three-dimensional model of circumferential clearance of elliptic section was established,and the formula of circumferential clearance angle(θ) at any swing angle and rotating angle was deduced,the changing law of θ with swing angle and rotating angle was obtained by using Matlab software.The results show that θ is related to the short and long half axle of the elliptical raceway,radius of steal ball,turning radius of steal ball,eccentricity,swing angle and rotating angle.The six fluctuations of θ lead to the vibration and noise during the travelling.

  20. The circumferential resection margins status: A comparison of robotic, laparoscopic and open total mesorectal excision for mid and low rectal cancer.

    Science.gov (United States)

    de Jesus, J P; Valadão, M; de Castro Araujo, R O; Cesar, D; Linhares, E; Iglesias, A C

    2016-06-01

    Minimally invasive surgery for rectal cancer (RC) is now widely performed via the laparoscopic approach, but robotic-assisted surgery may overcome some limitations of laparoscopy in RC treatment. We compared the rate of positive circumferential margins between robotic, laparoscopic and open total mesorectal excision (TME) for RC in our institution. Mid and low rectal adenocarcinoma patients consecutively submitted to robotic surgery were compared to laparoscopic and open approach. From our prospective database, 59 patients underwent robotic-assisted rectal surgery from 2012 to 2015 (RTME group) were compared to our historical control group comprising 200 open TME (OTME group) and 41 laparoscopic TME (LTME group) approaches from July 2008 to February 2012. Primary endpoint was to compare the rate of involved circumferential resection margins (CRM) and the mean CRM between the three groups. Secondary endpoint was to compare the mean number of resected lymph nodes between the three groups. CRM involvement was demonstrated in 20 patients (15.5%) in OTME, 4 (16%) in LTME and 9 (16.4%) in the RTME (p = 0.988). The mean CRM in OTME, LTME and RTME were respectively 0.6 cm (0-2.7), 0.7 cm (0-2.0) and 0.6 cm (0-2.0) (p = 0.960). Overall mean LN harvest was 14 (0-56); 16 (0-52) in OTME, 13 (1-56) in LTME and 10 (0-45) in RTME (p = 0.156). Our results suggest that robotic TME has the same oncological short-term results when compared to the open and laparoscopic technique, and it could be safely offered for the treatment of mid and low rectal cancer. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Assessment of Extent and Degree of Thermal Damage to Polymeric Materials in the Three Mile Island Unit 2 Reactor Building

    International Nuclear Information System (INIS)

    Alvares, N. J.

    1984-02-01

    Thermal damage to susceptible materials in accessible regions of the TMI-2 reactor building shows damage-distribution patterns that indicate non-uniform intensity of exposure. No clear explanation for non-uniformity is found in existing evidence; e.g., in some regions a lack of thermally susceptible materials frustrates analysis. Elsewhere, burned materials are present next to materials that seem similar but appear unscathed-leading to conjecture that the latter materials preferentially absorb water vapor during periods of high local steam concentration. Most of the polar crane pendant shows heavy burns on one half of its circumferential surface. This evidence suggests that the polar crane pendant side that experienced heaviest burn damage was exposed to intense radiant energy from a transient fire plume in the reactor containment volume. Tests and simple heat-transfer calculations based on pressure and temperature records from the accident show that the atmosphere inside the reactor building was probably 8% hydrogen in air, a value not inconsistent with the extent of burn damage. Burn-pattern geography indicates uniform thermal exposure in the dome volume to the 406-ft level (about 6 ft below the polar crane girder), partial thermal exposure in the volume between the 406- and 347-ft levels as indicated by the polar crane cable, and lack of damage to most thermally susceptible materials in the west quadrant of the reactor building; some evidence of thermal exposure Is seen in the free volume between the 305- and 347-ft levels. (author)

  2. Effect of the circumferential resection margin on survival following rectal cancer surgery.

    Science.gov (United States)

    Kelly, S B; Mills, S J; Bradburn, D M; Ratcliffe, A A; Borowski, D W

    2011-04-01

    The aim was to determine the effect of the circumferential resection margin (CRM) on overall survival following surgical excision of rectal cancer. The effect of CRM on survival was examined by case mix-adjusted analysis of patients undergoing potentially curative excision of a rectal cancer between 1998 and 2002. Of 1896 patients, 1561 (82.3 per cent) had recorded data on the CRM. In 232 patients (14.9 per cent) tumour was found 1 mm or less from the CRM. In 370 patients (23.7 per cent) it was over 1 mm but no more than 5 mm from the CRM, and in 288 (18.4 per cent) it was over 5 mm but no more than 10 mm from the CRM. The remaining 671 patients (43.0 per cent) had a CRM exceeding 10 mm. Overall 5-year survival rates for these groups were 43.2, 51.7, 66.6 and 66.0 per cent respectively. Compared with patients with a CRM exceeding 10 mm, the adjusted risk of death was significantly increased for patients with a CRM of 1 mm or less (hazard ratio (HR) 1.61, P CRM (HR 1.02, P = 0.873). The adverse effect of a CRM greater than 1 mm but no larger than 5 mm was found particularly in mid-rectal cancers. A predicted CRM of 5 mm or less on preoperative staging should be considered for neoadjuvant treatment. Copyright © 2011 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

  3. Investigations of leak opening and outflow behaviour on straight pipes with circumferential cracks with internal pressure and bending load

    International Nuclear Information System (INIS)

    Grebner, H.; Hoefler, A.; Hunger, H.

    1989-01-01

    The experiments carried out so far on straight pipes with circumferential cracks and results of subsequent calculations from this experiment are introduced. The subsequent calculations are not yet completed at all points. From the experiments one can record that the selected crack sizes and stresses have guaranteed stable crack behaviour in all cases. The comparison of experimental and calculated crack openings shows satisfactory agreement (difference about 20% for experiment E22.03. The compared leak rates show differences of up to about 50% (in isolated cases even more). For small leak rates (0.01 to 0.1 kg/sec), one can expect a difference of about 100% between calculation and experiment. For medium leak rates, we regard a maximum difference of about 30% as achievable. For large leak rates, the achievable accuracy plays no part for the detectability. (orig./DG) [de

  4. A new method to estimate left ventricular circumferential midwall systolic function by standard echocardiography: Concordance between models and validation by speckle tracking.

    Science.gov (United States)

    Ballo, Piercarlo; Nistri, Stefano; Bocelli, Arianna; Mele, Donato; Dini, Frank L; Galderisi, Maurizio; Zuppiroli, Alfredo; Mondillo, Sergio

    2016-01-15

    Assessment of left ventricular circumferential (LVcirc) systolic function by standard echocardiography can be performed by estimating midwall fractional shortening (mFS) and stress-corrected mFS (ScmFS). Their determination is based on spherical or cylindrical LV geometric models, which often yield discrepant values. We developed a new model based on a more realistic truncated ellipsoid (TE) LV shape, and explored the concordance between models among hypertensive patients. We also compared the relationships of different mFS and ScmFS estimates with indexes of LVcirc systolic strain. In 364 hypertensive subjects, mFS was determined using the spherical (mFSspher), cylindrical (mFScyl), and TE model (mFSTE). Corresponding values of ScmFSspher, ScmFScyl, and ScmFSTE were obtained. Global circumferential strain (GCS) and systolic strain rate (GCSR) were also measured by speckle tracking. The three models showed poor concordance for the estimation of mFS, with average differences ranging between 11% and 30% and wide limits of agreement. Similar results were found for ScmFS, where reclassification rates for the identification of abnormal LVcirc systolic function ranged between 18% and 29%. When tested against strain indexes, mFSTE and ScmFSTE showed the best correlations (R=0.81 and R=0.51, p<0.0001 for both) with GCS and GCSR. Multivariable analysis confirmed that mFSTE and ScmFSTE showed the strongest independent associations with LVcirc strain measures. Substantial discrepancies in LVcirc midwall systolic indexes exist between different models, supporting the need of model-specific normative data. The use of the TE model might provide indexes that show the best associations with established strain measures of LVcirc systolic function. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Radiofrequency catheter ablation of idiopathic ventricular arrhythmias originating from intramural foci in the left ventricular outflow tract: efficacy of sequential versus simultaneous unipolar catheter ablation.

    Science.gov (United States)

    Yamada, Takumi; Maddox, William R; McElderry, H Thomas; Doppalapudi, Harish; Plumb, Vance J; Kay, G Neal

    2015-04-01

    Idiopathic ventricular arrhythmias (VAs) originating from the left ventricular outflow tract (LVOT) sometimes require catheter ablation from the endocardial and epicardial sides for their elimination, suggesting the presence of intramural VA foci. This study investigated the efficacy of sequential and simultaneous unipolar radiofrequency catheter ablation from the endocardial and epicardial sides in treating intramural LVOT VAs. Fourteen consecutive LVOT VAs, which required sequential or simultaneous irrigated unipolar radiofrequency ablation from the endocardial and epicardial sides for their elimination, were studied. The first ablation was performed at the site with the earliest local ventricular activation and best pace map on the endocardial or epicardial side. When the first ablation was unsuccessful, the second ablation was delivered on the other surface. If this sequential unipolar ablation failed, simultaneous unipolar ablation from both sides was performed. The first ablation was performed on the epicardial side in 9 VAs and endocardial side in 5 VAs. The intramural LVOT VAs were successfully eliminated by the sequential (n=9) or simultaneous (n=5) unipolar catheter ablation. Simultaneous ablation was most likely to be required for the elimination of the VAs when the distance between the endocardial and epicardial ablation sites was >8 mm and the earliest local ventricular activation time relative to the QRS onset during the VAs of sequential unipolar radiofrequency ablation and sometimes required simultaneous ablation from both the endocardial and epicardial sides. © 2015 American Heart Association, Inc.

  6. Tissue Motion and Assembly During Early Cardiovascular Morphogenesis

    Science.gov (United States)

    Rongish, Brenda

    2010-03-01

    Conventional dogma in the field of cardiovascular developmental biology suggests that cardiac precursor cells migrate to the embryonic midline to form a tubular heart. These progenitors are believed to move relative to their extracellular matrix (ECM); responding to stimulatory and inhibitory cues in their environment. The tubular heart that is formed by 30 hours post fertilization is comprised of two concentric layers: the muscular myocardium and the endothelial-like endocardium, which are separated by a thick layer of ECM believed to be secreted predominantly by the myocardial cells. Here we describe the origin and motility of fluorescently tagged endocardial precursors in transgenic (Tie1-YFP) quail embryos (R. Lansford, Caltech) using epifluorescence time-lapse imaging. To visualize the environment of migrating endocardial progenitors, we labeled two ECM components, fibronectin and fibrillin-2, via in vivo microinjection of fluorochrome-conjugated monoclonal antibodies. Dynamic imaging was performed at stages encompassing tubular heart assembly and early looping. We established the motion of endocardial precursor cells and presumptive cardiac ECM fibrils using both object tracking and particle image velocimetry (image cross correlation). We determined the relative importance of directed cell autonomous motility versus passive tissue movements in endocardial morphogenesis. The data show presumptive endocardial cells and cardiac ECM fibrils are swept passively into the anterior and posterior poles of the elongating tubular heart. These quantitative data indicate the contribution of cell autonomous motility displayed by endocardial precursors is limited. Thus, tissue motion drives most of the cell displacements during endocardial morphogenesis.

  7. Circumferential or sectored beam arrangements for stereotactic body radiation therapy (SBRT) of primary lung tumors: Effect on target and normal-structure dose-volume metrics

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Mara W. [Broad Institute of MIT and Harvard, Cambridge, MA (United States); Department of Physics, Brandeis University, Waltham, MA (United States); Kato, Catherine M. [Macalester College, St. Paul, MN (United States); Carson, Kelly M.P. [The University of North Carolina, Chapel Hill, NC (United States); Matsunaga, Nathan M. [Santa Clara University, Santa Clara, CA (United States); Arao, Robert F. [Department of Public Health and Preventive Medicine, Oregon Health and Science University, Portland, OR (United States); Doss, Emily J. [Department of Internal Medicine, Providence St. Vincent Medical Center, Portland, OR (United States); McCracken, Charles L. [Department of Radiation Medicine, Oregon Health and Science University, Portland, OR (United States); Meng, Lu Z. [Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, Sacramento, CA (United States); Chen, Yiyi [Department of Public Health and Preventive Medicine, Oregon Health and Science University, Portland, OR (United States); Laub, Wolfram U.; Fuss, Martin [Department of Radiation Medicine, Oregon Health and Science University, Portland, OR (United States); Department of Nuclear Engineering and Radiation Health Physics, Oregon State University, Corvallis, OR (United States); Tanyi, James A., E-mail: tanyij@ohsu.edu [Department of Radiation Medicine, Oregon Health and Science University, Portland, OR (United States); Department of Nuclear Engineering and Radiation Health Physics, Oregon State University, Corvallis, OR (United States)

    2013-01-01

    To compare 2 beam arrangements, sectored (beam entry over ipsilateral hemithorax) vs circumferential (beam entry over both ipsilateral and contralateral lungs), for static-gantry intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 60 consecutive patients treated using stereotactic body radiation therapy (SBRT) for primary non–small-cell lung cancer (NSCLC) formed the basis of this study. Four treatment plans were generated per data set: IMRT/VMAT plans using sectored (-s) and circumferential (-c) configurations. The prescribed dose (PD) was 60 Gy in 5 fractions to 95% of the planning target volume (PTV) (maximum PTV dose ∼ 150% PD) for a 6-MV photon beam. Plan conformality, R{sub 50} (ratio of volume circumscribed by the 50% isodose line and the PTV), and D{sub 2} {sub cm} (D{sub max} at a distance ≥2 cm beyond the PTV) were evaluated. For lungs, mean doses (mean lung dose [MLD]) and percent V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} Gy were assessed. Spinal cord and esophagus D{sub max} and D{sub 5}/D{sub 50} were computed. Chest wall (CW) D{sub max} and absolute V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} {sub Gy} were reported. Sectored SBRT planning resulted in significant decrease in contralateral MLD and V{sub 10}/V{sub 5} {sub Gy}, as well as contralateral CW D{sub max} and V{sub 10}/V{sub 5} {sub Gy} (all p < 0.001). Nominal reductions of D{sub max} and D{sub 5}/D{sub 50} for the spinal cord with sectored planning did not reach statistical significance for static-gantry IMRT, although VMAT metrics did show a statistically significant decrease (all p < 0.001). The respective measures for esophageal doses were significantly lower with sectored planning (p < 0.001). Despite comparable dose conformality, irrespective of planning configuration, R{sub 50} significantly improved with IMRT

  8. The stability of through-wall circumferential cracks in cylindrical pipes subjected to bending loads

    International Nuclear Information System (INIS)

    Smith, E.

    1983-01-01

    Tada, Paris and Gamble have used the tearing modulus approach to show that when a circumferential through-wall crack exists in a 304 SS circular cylindrical pipe, and the pipe is subjected to an applied bending moment, then crack growth requires the rotation at the pipe-ends to be increased, (i.e. crack growth is stable), unless the pipe length is unduly large. On this basis it was concluded that unstable fracture is unlikely to occur in BWR SS piping, when the system is designed in accord with the ASME Code load levels for normal operation and anticipated transients. The Tada-Paris-Gamble analysis focuses on the inter-relation between instability and the onset of crack extension, and does not specifically consider the possibility that a crack might become unstable after some stable crack extension. The paper addresses this aspect of the crack stability problem using a crack tip opening angle criterion for crack extension, which has similarities with the tearing modulus approach. The results show that unstable fracture should not occur even after some stable crack extension, again provided that the pipe length is not unduly large. In other words, guillotine failure of a pipe in a BWR system is unlikely, even though the ASME Code limiting stress levels as might be exceeded, as may be the case with a very severe earthquake. (orig./HP)

  9. Occurrence and prognostic value of circumferential resection margin involvement for patients with rectal cancer.

    Science.gov (United States)

    Wang, Cun; Zhou, Zong-guang; Yu, Yong-yang; Shu, Ye; Li, Yuan; Yang, Lie; Li, Li

    2009-04-01

    Total mesorectal excision (TME) was advocated owning to the reduction in local failure, while deficiency in pathologic details limited monitoring of surgical quality assurance. Here, we aimed to examine circumferential resection margin (CRM) by large tissue slice, discussing its rule in occurrence and relationship with prognosis, thus providing proof for the adoption of TME principles and the application of adjuvant therapy. Specimens of 106 patients with rectal cancer, who underwent potentially curative resection from December 2001 to September 2002, were examined. Follow-up data were collected. Altogether, 2,068 mesorectal nodes were examined with 272 involved by tumor. CRM involvement (CRMI) was examined in 20 specimens. In these 20 cases, seven, nine, and four were caused by tumor infiltration, lymph node metastasis, and both, respectively. Occurrence of CRMI was more common for lower-located cancers while also statistically related to tumor differentiation, infiltration, and lymph node metastasis. The difference in local recurrence rate, general recurrence rate, disease-free survival rate, and overall survival rate between the group with CRMI and the group without were all proven to be significant. Detailed pathologic examination, including status of CRM, is advocated since it provides accurate prognostic information. Surgeons could maximize the probability of cure by following the principle of TME. Preoperative adjuvant therapy was essential for advanced staged and lower-located lesions, which implied likelihood of CRMI.

  10. Circumferential tracheal resection with primary anastomosis for post-intubation tracheal stenosis: study of 24 cases.

    Science.gov (United States)

    Negm, Hesham; Mosleh, Mohamed; Fathy, Hesham

    2013-09-01

    The objective of this study is to evaluate the results of circumferential tracheal and cricotracheal resection with primary anastomosis for the treatment of post-intubation tracheal and cricotracheal stenosis. This is a retrospective analytical study. A total number of 24 patients were included in this study. The relevant preoperative, operative and postoperative records were collected and analyzed. Twenty patients were finally symptom-free reflecting an anastomosis success rate of 83.3 %. Variable grades of anastomotic restenosis occurred in 11 (45.8 %) patients, three patients were symptom-free and eight had airway obstructive symptoms. Four out of the eight patients with symptomatic restenosis were symptom-free with endoscopic dilatation while the remaining four patients required a permanent airway appliance (T-tube, tracheostomy) for the relief of airway obstruction and this group was considered as anastomotic failure. Cricoid involvement, associated cricoid resection and the type of anastomosis were the variables that had statistical impact on the occurrence of restenosis (P = 0.017, 0.017, 0.05; respectively). Tracheal resection with primary anastomosis is a safe effective treatment method for post-intubation tracheal stenosis in carefully selected patients. Restenosis does not always mean failure of the procedure since it may be successfully managed with endoscopic dilatation.

  11. Quantitative stress-redistribution planar T1-201 scintigraphy: Assessment of the extent of hypoperfused myocardium by relationship to angiographic findings

    International Nuclear Information System (INIS)

    Bassir, R.; Maddahi, J.; Garcia, E.

    1984-01-01

    The size of hypoperfused myocardium (HM) in coronary artery (CA) disease (D) potentially provides a prognostic index that may not be accurately assess by conventional angiographic classification. The authors studied 62 consecutive patients (pts) with planar stress-redistribution T1-201 scintigraphy (T1-201) and coronary arteriography who did not have prior myocardial infarction and achieved 85% predicted maximum heart rate on exercise. Of 62 pts, 42 had CAD (>50% stenosis). For T1-201 quantification of the size of HM, maximum count circumferential profiles of initial distribution and % washout were obtained and compared to previously established normal limits. The area enclosed between the normal limits and the abnormal portion of the pt's profiles represented a quantitative T1-201 jeopardy score (JS). Despite increasing T1-201 JS from 1 to 3 vessel (V) and left-main (LM) D, significant overlap between the different angiographic groups was observed; of 45 pts with mild JS (<300), 14 (31%) had 3VD and/or LMD. The angiographic extent of CAD was also analyzed using a method (CLASS) proposed by Gensini et al based on the CA territory, location and severity of stenosis, and collateral circulation. T1-201 JS correlated significantly with CLASS (r=.78, p<.01). Of the 45 pts with mild JS, only 5 (11%) had severe CLASS score. Thus, the size of the hypoperfused myocardium by quantitative stress- and redistribution T1-201 correlates better with a more complex angiographic estimate of myocardium at risk than conventional 1, 2, and 3 vessel disease classification

  12. The Prognostic Value of Circumferential Resection Margin Involvement in Patients with Extraperitoneal Rectal Cancer.

    Science.gov (United States)

    Shin, Dong Woo; Shin, Jin Yong; Oh, Sung Jin; Park, Jong Kwon; Yu, Hyeon; Ahn, Min Sung; Bae, Ki Beom; Hong, Kwan Hee; Ji, Yong Il

    2016-04-01

    The prognostic influence of circumferential resection margin (CRM) status in extraperitoneal rectal cancer probably differs from that of intraperitoneal rectal cancer because of its different anatomical and biological behaviors. However, previous reports have not provided the data focused on extraperitoneal rectal cancer. Therefore, the aim of this study was to examine the prognostic significance of the CRM status in patients with extraperitoneal rectal cancer. From January 2005 to December 2008, 248 patients were treated for extraperitoneal rectal cancer and enrolled in a prospectively collected database. Extraperitoneal rectal cancer was defined based on tumors located below the anterior peritoneal reflection, as determined intraoperatively by a surgeon. Cox model was used for multivariate analysis to examine risk factors of recurrence and mortality in the 248 patients, and multivariate logistic regression analysis was performed to identify predictors of recurrence and mortality in 135 patients with T3 rectal cancer. CRM involvement for extraperitoneal rectal cancer was present in 29 (11.7%) of the 248 patients, and was the identified predictor of local recurrence, overall recurrence, and death by multivariate Cox analysis. In the 135 patients with T3 cancer, CRM involvement was found to be associated with higher probability of local recurrence and mortality. In extraperitoneal rectal cancer, CRM involvement is an independent risk factor of recurrence and survival. Based on the results of the present study, it seems that CRM involvement in extraperitoneal rectal cancer is considered an indicator for (neo)adjuvant therapy rather than conventional TN status.

  13. Limitations and ceiling effects with circumferential minimally invasive correction techniques for adult scoliosis: analysis of radiological outcomes over a 7-year experience.

    Science.gov (United States)

    Anand, Neel; Baron, Eli M; Khandehroo, Babak

    2014-05-01

    Minimally invasive correction of adult scoliosis is a surgical method increasing in popularity. Limited data exist, however, as to how effective these methodologies are in achieving coronal plane and sagittal plane correction in addition to improving spinopelvic parameters. This study serves to quantify how much correction is possible with present circumferential minimally invasive surgical (cMIS) methods. Ninety patients were selected from a database of 187 patients who underwent cMIS scoliosis correction. All patients had a Cobb angle greater than 15°, 3 or more levels fused, and availability of preoperative and postoperative 36-inch standing radiographs. The mean duration of follow-up was 37 months. Preoperative and postoperative Cobb angle, sagittal vertical axis (SVA), coronal balance, lumbar lordosis (LL), and pelvic incidence (PI) were measured. Scatter plots were performed comparing the pre- and postoperative radiological parameters to calculate ceiling effects for SVA correction, Cobb angle correction, and PI-LL mismatch correction. The mean preoperative SVA value was 60 mm (range 11.5-151 mm); the mean postoperative value was 31 mm (range 0-84 mm). The maximum SVA correction achieved with cMIS techniques in any of the cases was 89 mm. In terms of coronal Cobb angle, a mean correction of 61% was noted, with a mean preoperative value of 35.8° (range 15°-74.7°) and a mean postoperative value of 13.9° (range 0°-32.5°). A ceiling effect for Cobb angle correction was noted at 42°. The ability to correct the PI-LL mismatch to 10° was limited to cases in which the preoperative PI-LL mismatch was 38° or less. Circumferential MIS techniques as currently used for the treatment of adult scoliosis have limitations in terms of their ability to achieve SVA correction and lumbar lordosis. When the preoperative SVA is greater than 100 mm and a substantial amount of lumbar lordosis is needed, as determined by spinopelvic parameter calculations, surgeons should

  14. Thermal fatigue crack growth on a thick wall tube containing a semi elliptical circumferential crack

    International Nuclear Information System (INIS)

    Deschanels, H.; Wakai, T.; Lacire, M.H.; Michel, B.

    2001-01-01

    In order to check the ability of the simplified assessment procedure (A16 guide) to predict fatigue crack growth, a benchmark problem was conducted. This work is carried out under the project ''agreement on the Exchange of Information and Collaboration in the field of Research and Development of Fast Breeder Reactor (FBR) between Europe (EU) and Japan''. Experimental work is conducted by PNC using Air cooled Thermal transient Test Facility (ATTF). Specimen is a thick wall tube containing a semi elliptical (3-D) circumferential crack and subjected to cyclic thermal transients. The constitutive material is the 304 austenitic stainless steel type SUS304. Due to thermal shock (650 C-300 C) the stress distribution through the wall is non-linear and well approximated using a 3 rd order polynomial. When comparing computations and tests data we observe a good agreement for the crack propagation in length. In crack depth, accurate results are obtained in the first part of the test, but on the later stage of the experiment the computations slightly underestimate the propagation (deep crack). In addition, we notice the importance of good evaluation of fracture mechanics parameters for non-linear stress distribution through the wall. At present A16 guide handbook gives stress intensity factor solutions for non-linear stress distribution through the wall. (author)

  15. Crack opening displacement of circumferential through-wall cracked cylinders subjected to tension and in-plane bending loads

    International Nuclear Information System (INIS)

    Yoo, Yeon-Sik

    2003-01-01

    This study is concerned with crack opening displacements (CODs) of cylinders with a circumferential through-crack which is subjected to tension and in-plane bending loads. Most studies about crack opening behavior have performed on membrane and global bending stresses. Moreover, they cannot be valid for large-scale structures. For simplicity on evaluation for structural integrity, crack opening displacement has been often calculated by plate or pipe model considering almost stresses as a membrane component. However, it is important to investigate ones close to real crack opening behaviors under stress states for reliability on evaluation. The results must be directly related to evaluate leakage detection in reactor vessel and the primary piping system of FBR structures. From that purpose, a series of FEM analyses were performed, and hence the characteristics of COD under an in-plane bending stress were compared with those under a membrane stress. In addition, the plate model was indicated to be unreasonable for application on large-scale pipes by comparing the plate model with the pipe model. The results of this study are expected to be valid for leakage evaluation of high temperature structures especially. (author)

  16. Multisensor Analyzed Sea Ice Extent - Northern Hemisphere (MASIE-NH)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Multisensor Analyzed Sea Ice Extent Northern Hemisphere (MASIE-NH) products provide measurements of daily sea ice extent and sea ice edge boundary for the...

  17. Real-time flood extent maps based on social media

    Science.gov (United States)

    Eilander, Dirk; van Loenen, Arnejan; Roskam, Ruud; Wagemaker, Jurjen

    2015-04-01

    During a flood event it is often difficult to get accurate information about the flood extent and the people affected. This information is very important for disaster risk reduction management and crisis relief organizations. In the post flood phase, information about the flood extent is needed for damage estimation and calibrating hydrodynamic models. Currently, flood extent maps are derived from a few sources such as satellite images, areal images and post-flooding flood marks. However, getting accurate real-time or maximum flood extent maps remains difficult. With the rise of social media, we now have a new source of information with large numbers of observations. In the city of Jakarta, Indonesia, the intensity of unique flood related tweets during a flood event, peaked at 8 tweets per second during floods in early 2014. A fair amount of these tweets also contains observations of water depth and location. Our hypothesis is that based on the large numbers of tweets it is possible to generate real-time flood extent maps. In this study we use tweets from the city of Jakarta, Indonesia, to generate these flood extent maps. The data-mining procedure looks for tweets with a mention of 'banjir', the Bahasa Indonesia word for flood. It then removes modified and retweeted messages in order to keep unique tweets only. Since tweets are not always sent directly from the location of observation, the geotag in the tweets is unreliable. We therefore extract location information using mentions of names of neighborhoods and points of interest. Finally, where encountered, a mention of a length measure is extracted as water depth. These tweets containing a location reference and a water level are considered to be flood observations. The strength of this method is that it can easily be extended to other regions and languages. Based on the intensity of tweets in Jakarta during a flood event we can provide a rough estimate of the flood extent. To provide more accurate flood extend

  18. Zero-fluoroscopy cryothermal ablation of atrioventricular nodal re-entry tachycardia guided by endovascular and endocardial catheter visualization using intracardiac echocardiography (Ice&ICE Trial).

    Science.gov (United States)

    Luani, Blerim; Zrenner, Bernhard; Basho, Maksim; Genz, Conrad; Rauwolf, Thomas; Tanev, Ivan; Schmeisser, Alexander; Braun-Dullaeus, Rüdiger C

    2018-01-01

    Stochastic damage of the ionizing radiation to both patients and medical staff is a drawback of fluoroscopic guidance during catheter ablation of cardiac arrhythmias. Therefore, emerging zero-fluoroscopy catheter-guidance techniques are of great interest. We investigated, in a prospective pilot study, the feasibility and safety of the cryothermal (CA) slow-pathway ablation in patients with symptomatic atrioventricular-nodal-re-entry-tachycardia (AVNRT) using solely intracardiac echocardiography (ICE) for endovascular and endocardial catheter visualization. Twenty-five consecutive patients (mean age 55.6 ± 12.0 years, 17 female) with ECG-documentation or symptoms suggesting AVNRT underwent an electrophysiology study (EPS) in our laboratory utilizing ICE for catheter navigation. Supraventricular tachycardia was inducible in 23 (92%) patients; AVNRT was confirmed by appropriate stimulation maneuvers in 20 (80%) patients. All EPS in the AVNRT subgroup could be accomplished without need for fluoroscopy, relying solely on ICE-guidance. CA guided by anatomical location and slow-pathway potentials was successful in all patients, median cryo-mappings = 6 (IQR:3-10), median cryo-ablations = 2 (IQR:1-3). Fluoroscopy was used to facilitate the trans-septal puncture and localization of the ablation substrate in the remaining 3 patients (one focal atrial tachycardia and two atrioventricular-re-entry-tachycardias). Mean EPS duration in the AVNRT subgroup was 99.8 ± 39.6 minutes, ICE guided catheter placement 11.9 ± 5.8 minutes, time needed for diagnostic evaluation 27.1 ± 10.8 minutes, and cryo-application duration 26.3 ± 30.8 minutes. ICE-guided zero-fluoroscopy CA in AVNRT patients is feasible and safe. Real-time visualization of the true endovascular borders and cardiac structures allow for safe catheter navigation during the ICE-guided EPS and might be an alternative to visualization technologies using geometry reconstructions. © 2017 Wiley Periodicals, Inc.

  19. Improvement of C*-integral and Crack Opening Displacement Estimation Equations for Thin-walled Pipes with Circumferential Through-wall Cracks

    International Nuclear Information System (INIS)

    Park, Jeong Soon; Jhung, Myung Jo

    2012-01-01

    Since the LBB(Leak-Before-Break) concept has been widely applied to high energy piping systems in the pressurized water reactors, a number of engineering estimation methods had been developed for J-integral and COD values. However, those estimation methods were mostly reliable for relatively thick-walled pipes about R m /t=5 or 10. As the LBB concept might be considered in the design stage of the SFR (Sodium-cooled Fast Reactor) which has relatively thin-walled pipes due to its low design pressure, the applicability of current estimation methods should be investigated for thin-walled pipes. Along with the J-integral and COD, the estimation method for creep fracture mechanics parameters, C*- integral and COD rate, is required because operating temperature of SFR is high enough to induce creep in the structural materials. In this study, the applicability of the current C*- integral and COD estimation methods to thin-walled pipes is studied for a circumferential through-wall crack using the finite element (FE) method. Based on the FE results, enhancement of the current estimation methods is made

  20. Endocardial cushion defect

    Science.gov (United States)

    ... Philadelphia, PA: Elsevier; 2016:chap 426. Kouchoukos NT, Blackstone EH, Hanley FL, Kirklin JK. Atrioventricular septal defect. In: Kouchoukos NT, Blackstone EH, Hanley FL, Kirklin JK, eds. Kirklin/Barratt- ...

  1. Quantitative analysis of Tl-201 myocardial perfusion image with special reference to circumferential profile method

    Energy Technology Data Exchange (ETDEWEB)

    Miyanaga, Hajime [Kyoto Prefectural Univ. of Medicine (Japan)

    1982-08-01

    A quantitative analysis of thallium-201 myocardial perfusion image (MPI) was attempted by using circumferential profile method (CPM) and the first purpose of this study is to assess the clinical utility of this method for the detection of myocardial ischemia. In patients with coronary artery disease, CPM analysis to exercise T1-MPI showed high sensitivity (9/12, 75%) and specificity (9/9, 100%), whereas exercise ECG showed high sensitivity (9/12, 75%), but relatively low specificity (7/9, 78%). In patients with myocardial infarction, CPM also showed high sensitivity (34/38, 89%) for the detection of myocardial necrosis, compared with visual interpretation (31/38, 81%) and with ECG (31/38, 81%). Defect score was correlated well with the number of abnormal Q waves. In exercise study, CPM was also sensitive to the change of perfusion defect in T1-MPI produced by exercise. So the results indicate that CPM is a good method not only quantitatively but also objectively to analyze T1-MPI. Although ECG is the most commonly used diagnostic tool for ischemic heart disease, several exercise induced ischemic changes in ECG have been still on discussion as criteria. So the second purpose of this study is to evaluate these ischemic ECG changes by exercise T1-MPI analized quantitatively. ST depression (ischemic 1 mm and junctional 2 mm or more), ST elevation (1 mm or more), and coronary T wave reversion in exercise ECG were though to be ischemic changes.

  2. Gonioscopy-assisted Transluminal Trabeculotomy: An Ab Interno Circumferential Trabeculotomy: 24 Months Follow-up.

    Science.gov (United States)

    Grover, Davinder S; Smith, Oluwatosin; Fellman, Ronald L; Godfrey, David G; Gupta, Aditi; Montes de Oca, Ildamaris; Feuer, William J

    2018-05-01

    The purpose of this study was to provide 24-month follow-up on surgical success and safety of an ab interno circumferential 360-degree trabeculotomy. Chart review of patients who underwent a gonioscopy-assisted transluminal trabeculotomy (GATT) procedure was performed by 4 of the authors (D.S.G., O.S., R.L.F., and D.G.G.). The surgery was performed in adults with various types of open-angle glaucoma with preoperative intraocular pressures (IOPs) of ≥18 mm Hg. In total, 198 patients aged 24 to 89 years underwent the GATT procedure with at least 18 months follow-up. Patients with primary open-angle glaucoma had an average IOP decrease of 9.2 mm Hg at 24 months with an average decrease of 1.43 glaucoma medications. The mean percentage of IOP decrease in these primary open-angle glaucoma groups at 24 months was 37.3%. In secondary open-angle glaucoma, at 24 months there was an average decrease in IOP of 14.1 mm Hg on an average of 2.0 fewer medications. The mean percentage of IOP decrease in the secondary open-angle glaucoma groups at 24 months was 49.8%. The cumulative proportion of failure at 24 months ranged from 0.18 to 0.48, depending on the group. In all 6 study groups, at all 5 postoperative time points (3, 6, 12, 18, and 24 mo) the mean IOP and reduction in glaucoma medications was significantly reduced from baseline (P<0.001) with the exception of one time point. The 24-month results demonstrate that GATT is relatively safe and effective in treating various forms of open-angle glaucoma. The long-term results for GATT are relatively equivalent to those previously reported for GATT and ab externo trabeculotomy studies.

  3. The influence of circumferential resection margin status on loco-regional recurrence in esophageal squamous cell carcinoma.

    Science.gov (United States)

    Park, Hae Jin; Kim, Hak Jae; Chie, Eui Kyu; Kang, Chang Hyun; Kim, Young Tae

    2013-06-01

    To analyze treatment outcomes and patterns of recurrence, and to examine the impact of adjuvant postoperative radiotherapy (PORT) after esophagectomy in esophageal squamous cell carcinoma (SqCC) regarding the status of circumferential resection margin (CRM). We performed a retrospective review of esophageal cancer patients operated in Seoul National University Hospital between 2003 and 2010. Pathologically proven T3 SqCC patients with written reports mentioning the status of CRM were selected. Fifty-nine out of 71 patients (83.1%) had CRM+. Twenty-eight patients had radiotherapy in CRM+ and CRM-, respectively. The median follow-up period was 17.1 months (range: 5.2-63.1). Median survival and 2-year overall survival were 13.8 months and 41.9% in CRM+, and 27.3 months and 74.1% in CRM-, respectively. Loco-regional relapse-free survival (LRRFS) rate at 2 years was 33.6% and 74.1% in each groups (P = 0.029). Loco-regional recurrence was the major pattern of failure in CRM+. PORT did not improve LRRFS. The esophageal SqCC patients with CRM+ after resection showed worse LRRFS. This finding validated the prognostic value of CRM status. Nevertheless, we failed to demonstrate the benefits of adjuvant PORT in CRM+. This might suggest the necessity of neoadjuvant therapy to decrease the CRM+ rate after esophagectomy. Copyright © 2012 Wiley Periodicals, Inc.

  4. Updated Vertical Extent of Collision Damage

    DEFF Research Database (Denmark)

    Tagg, R.; Bartzis, P.; Papanikolaou, P.

    2002-01-01

    The probabilistic distribution of the vertical extent of collision damage is an important and somewhat controversial component of the proposed IMO harmonized damage stability regulations for cargo and passenger ships. The only pre-existing vertical distribution, currently used in the international...

  5. Nondestructive Evaluation of Functionally Graded Subsurface Damage on Cylinders in Nuclear Installations Based on Circumferential SH Waves

    Directory of Open Access Journals (Sweden)

    Zhen Qu

    2016-01-01

    Full Text Available Subsurface damage could affect the service life of structures. In nuclear engineering, nondestructive evaluation and detection of the evaluation of the subsurface damage region are of great importance to ensure the safety of nuclear installations. In this paper, we propose the use of circumferential horizontal shear (SH waves to detect mechanical properties of subsurface regions of damage on cylindrical structures. The regions of surface damage are considered to be functionally graded material (FGM and the cylinder is considered to be a layered structure. The Bessel functions and the power series technique are employed to solve the governing equations. By analyzing the SH waves in the 12Cr-ODS ferritic steel cylinder, which is frequently applied in the nuclear installations, we discuss the relationship between the phase velocities of SH waves in the cylinder with subsurface layers of damage and the mechanical properties of the subsurface damaged regions. The results show that the subsurface damage could lead to decrease of the SH waves’ phase velocity. The gradient parameters, which represent the degree of subsurface damage, can be evaluated by the variation of the SH waves’ phase velocity. Research results of this study can provide theoretical guidance in nondestructive evaluation for use in the analysis of the reliability and durability of nuclear installations.

  6. A method for the measurement of dispersion curves of circumferential guided waves radiating from curved shells: experimental validation and application to a femoral neck mimicking phantom

    Science.gov (United States)

    Nauleau, Pierre; Minonzio, Jean-Gabriel; Chekroun, Mathieu; Cassereau, Didier; Laugier, Pascal; Prada, Claire; Grimal, Quentin

    2016-07-01

    Our long-term goal is to develop an ultrasonic method to characterize the thickness, stiffness and porosity of the cortical shell of the femoral neck, which could enhance hip fracture risk prediction. To this purpose, we proposed to adapt a technique based on the measurement of guided waves. We previously evidenced the feasibility of measuring circumferential guided waves in a bone-mimicking phantom of a circular cross-section of even thickness. The goal of this study is to investigate the impact of the complex geometry of the femoral neck on the measurement of guided waves. Two phantoms of an elliptical cross-section and one phantom of a realistic cross-section were investigated. A 128-element array was used to record the inter-element response matrix of these waveguides. This experiment was simulated using a custom-made hybrid code. The response matrices were analyzed using a technique based on the physics of wave propagation. This method yields portions of dispersion curves of the waveguides which were compared to reference dispersion curves. For the elliptical phantoms, three portions of dispersion curves were determined with a good agreement between experiment, simulation and theory. The method was thus validated. The characteristic dimensions of the shell were found to influence the identification of the circumferential wave signals. The method was then applied to the signals backscattered by the superior half of constant thickness of the realistic phantom. A cut-off frequency and some portions of modes were measured, with a good agreement with the theoretical curves of a plate waveguide. We also observed that the method cannot be applied directly to the signals backscattered by the lower half of varying thicknesses of the phantom. The proposed approach could then be considered to evaluate the properties of the superior part of the femoral neck, which is known to be a clinically relevant site.

  7. Spiral-wave dynamics in a mathematical model of human ventricular tissue with myocytes and Purkinje fibers.

    Science.gov (United States)

    Nayak, Alok Ranjan; Panfilov, A V; Pandit, Rahul

    2017-02-01

    We present systematic numerical studies of the possible effects of the coupling of human endocardial and Purkinje cells at cellular and two-dimensional tissue levels. We find that the autorhythmic-activity frequency of the Purkinje cell in a composite decreases with an increase in the coupling strength; this can even eliminate the autorhythmicity. We observe a delay between the beginning of the action potentials of endocardial and Purkinje cells in a composite; such a delay increases as we decrease the diffusive coupling, and eventually a failure of transmission occurs. An increase in the diffusive coupling decreases the slope of the action-potential-duration-restitution curve of an endocardial cell in a composite. By using a minimal model for the Purkinje network, in which we have a two-dimensional, bilayer tissue, with a layer of Purkinje cells on top of a layer of endocardial cells, we can stabilize spiral-wave turbulence; however, for a sparse distribution of Purkinje-ventricular junctions, at which these two layers are coupled, we can also obtain additional focal activity and many complex transient regimes. We also present additional effects resulting from the coupling of Purkinje and endocardial layers and discuss the relation of our results to the studies performed in anatomically accurate models of the Purkinje network.

  8. The role of surgery in the treatment of post-infarction ventricular tachycardia. A 5 year experience.

    Science.gov (United States)

    Martinelli, L; Goggi, C; Graffigna, A; Salerno, J A; Chimienti, M; Klersy, C; Viganò, M

    1987-01-01

    The purpose of this report is to present a 5 year experience in electrophysiologically guided surgical treatment of post-infarction ventricular tachycardia (VT) in a consecutive series of 39 patients. In every case the arrhythmia was not responsive to pluripharmacological therapy. The diagnostic steps included preoperative endocardial, intraoperative epi- and endocardial mapping, automatically carried out when possible. Surgical techniques were: classic Guiraudon's encircling endocardial ventriculotomy (EEV), partial EEV, endocardial resection (ER), cryoablation or combined procedures. The hospital mortality was of 4 patients (10%). During the follow-up period (1-68 mo), 4 patients (11%) died of cardiac non-VT related causes. Among the survivors, 90% are in sinus rhythm. The authors consider electrophysiologically guided surgery a safe and reliable method for the treatment of post-infarction VT and suggest more extensive indications. They stress the importance of automatic mapping in pleomorphic and non-sustained VT, and the necessity of tailoring the surgical technique to the characteristics of each case.

  9. Michelin tire baby syndrome: a review of the literature and a proposal for diagnostic criteria with adoption of the name circumferential skin folds syndrome.

    Science.gov (United States)

    Rothman, Ilene L

    2014-01-01

    The term Michelin tire baby (MTB), named for the cartoon mascot of the Michelin Tire Company, has been used to describe babies with multiple symmetric circumferential rings of folded skin. In those reported with this phenotype who had skin biopsies, pathology has shown nevus lipomatosis, smooth muscle hamartoma, degenerative collagen, and scarring. Others did not undergo biopsy or had normal skin. Many individuals with the MTB phenotype have had a variety of other congenital anomalies. I review the literature on MTB and the history of the designation Michelin tire baby Syndrome (MTBS). Because the term MTBS has been poorly defined or not defined at all, I propose strict criteria for diagnosis. In doing so, it is recommended that the syndrome be renamed to avoid further confusion. © 2014 Wiley Periodicals, Inc.

  10. Ticagrelor, but not clopidogrel active metabolite, displays antithrombotic properties in the left atrial endocardium.

    Science.gov (United States)

    Reiner, Martin F; Breitenstein, Alexander; Holy, Erik W; Glanzmann, Martina; Amstalden, Heidi; Stämpfli, Simon F; Bonetti, Nicole R; Falk, Volkmar; Keller, Stephan; Savarese, Gianluigi; Benussi, Stefano; Maisano, Francesco; Lüscher, Thomas F; Beer, Jürg H; Steffel, Jan; Camici, Giovanni G

    2017-03-21

    Oral anticoagulation is considered standard therapy for stroke prevention in atrial fibrillation (AF). Endocardial activation triggers expression of pro-thrombotic mediators including tissue factor (TF) and plasminogen activator inhibitor-1 (PAI-1), and contributes to thrombus formation in the left atrial appendage (LAA) of AF patients. Recently, pleiotropic effects of specific P2Y12 receptor antagonists were demonstrated; however, whether these drugs possess antithrombotic effects on LAA endocardial cells currently remains unknown. LAA were obtained from 14 patients with known AF undergoing elective cardiac surgery including LAA removal at the University Hospital Zurich. LAA endocardial cells were isolated and pre-incubated with ticagrelor (10-7, 10-6, 10-5M) or clopidogrel active metabolite (CAM) (1.5 × 10-8, 1.5 × 10-7, 1.5 × 10-6 M) before stimulation with tumour necrosis factor-alpha (TNF-α) (10 ng/mL). Finally, TF and PAI-1 expression and activity were analysed. Ticagrelor, unlike CAM, concentration dependently decreased TNF-α-induced TF expression and TF activity in LAA endocardial cells. Further, ticagrelor, but not CAM reduced PAI-1 expression and enzyme activity in TNF-α-stimulated LAA endocardial cells. In contrast, TF pathway inhibitor (TFPI) remained unaffected by both dugs. Ticagrelor, but not CAM, reduces expression and activity of TF and PAI-1 in LAA endocardial cells isolated from patients with AF, indicating possible local antithrombotic effects. Such pleiotropic properties of ticagrelor may contribute to a reduction in thromboembolic complications in patients with AF. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  11. Crack-tip constraint analyses and constraint-dependent LBB curves for circumferential through-wall cracked pipes

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y.L.; Wang, G.Z., E-mail: gzwang@ecust.edu.cn; Xuan, F.Z.; Tu, S.T.

    2015-04-15

    Highlights: • Solution of constraint parameter τ* for through-wall cracked pipes has been obtained. • Constraint increases with increasing crack length and radius–thickness ratio of pipes. • Constraint-dependent LBB curve for through-wall cracked pipes has been constructed. • For increasing accuracy of LBB assessments, constraint effect should be considered. - Abstract: The leak-before-break (LBB) concept has been widely applied in the structural integrity assessments of pressured pipes in nuclear power plants. However, the crack-tip constraint effects in LBB analyses and designs cannot be incorporated. In this paper, by using three-dimensional finite element calculations, the modified load-independent T-stress constraint parameter τ* for circumferential through-wall cracked pipes with different geometries and crack sizes has been analyzed under different loading conditions, and the solutions of the crack-tip constraint parameter τ* have been obtained. Based on the τ* solutions and constraint-dependent J–R curves of a steel, the constraint-dependent LBB (leak-before-break) curves have been constructed. The results show that the constraint τ* increases with increasing crack length θ, mean radius R{sub m} and radius–thickness ratio R{sub m}/t of the pipes. In LBB analyses, the critical crack length calculated by the J–R curve of the standard high constraint specimen for pipes with shorter cracks is over-conservative, and the degree of conservatism increases with decreasing crack length θ, R{sub m} and R{sub m}/t. Therefore, the constraint-dependent LBB curves should be constructed to modify the over-conservatism and increase accuracy of LBB assessments.

  12. Reconstructed North American Snow Extent, 1900-1993

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains reconstructed monthly North American snow extent values for November through March, 1900-1993. Investigators used a combination of satellite...

  13. A quantitative analysis of Tl-201 myocardial perfusion image with special reference to circumferential profile method

    International Nuclear Information System (INIS)

    Miyanaga, Hajime

    1982-01-01

    A quantitative analysis of thallium-201 myocardial perfusion image (MPI) was attempted by using circumferential profile method (CPM) and the first purpose of this study is to assess the clinical utility of this method for the detection of myocardial ischemia. In patients with coronary artery disease, CPM analysis to exercise T1-MPI showed high sensitivity (9/12, 75%) and specificity (9/9, 100%), whereas exercise ECG showed high sensitivity (9/12, 75%), but relatively low specificity (7/9, 78%). In patients with myocardial infarction, CPM also showed high sensitivity (34/38, 89%) for the detection of myocardial necrosis, compared with visual interpretation (31/38, 81%) and with ECG (31/38, 81%). Defect score was correlated well with the number of abnormal Q waves. In exercise study, CPM was also sensitive to the change of perfusion defect in T1-MPI produced by exercise. So the results indicate that CPM is a good method not only quantitatively but also objectively to analyze T1-MPI. Although ECG is the most commonly used diagnostic tool for ischemic heart disease, several exercise induced ischemic changes in ECG have been still on discussion as criteria. So the second purpose of this study is to evaluate these ischemic ECG changes by exercise T1-MPI analized quantitatively. ST depression (ischemic 1 mm and junctional 2 mm or more), ST elevation (1 mm or more), and coronary T wave reversion in exercise ECG were though to be ischemic changes. (J.P.N.)

  14. Predictors of chronic pulmonary vein reconnections after contact force-guided ablation: importance of completing electrical isolation with circumferential lines and creating sufficient ablation lesion densities.

    Science.gov (United States)

    Nakamura, Kohki; Naito, Shigeto; Sasaki, Takehito; Minami, Kentaro; Take, Yutaka; Shimizu, Satoru; Yamaguchi, Yoshiaki; Yano, Toshiaki; Senga, Michiharu; Yamashita, Eiji; Sugai, Yoshinao; Kumagai, Koji; Funabashi, Nobusada; Oshima, Shigeru

    2016-12-01

    We aimed to identify the predictors of chronic pulmonary vein reconnections (CPVRs) after contact force (CF)-guided circumferential PV isolation (CPVI) of atrial fibrillation (AF). Forty-nine consecutive patients undergoing second ablation procedures for recurrent AF after CF-guided ablation were retrospectively studied. The CPVI was performed by point-by-point ablation with a target CF of 15-20 g. The incidence of CPVRs was evaluated along the right- and left-sided anterior and posterior CPVI regions (Ant-RPVs, Post-RPVs, Ant-LPVs, and Post-LPVs). CPVRs were observed in 30.6, 22.4, 20.4, and 32.7 % of patients along the Ant-RPVs, Post-RPVs, Ant-LPVs, and Post-LPVs, respectively (P = 0.436). In the multivariate logistic analyses, completing a left atrium-PV conduction block with touch-up ablation inside the initially estimated CPVI lines (Ant-RPVs, Post-RPVs, Ant-LPVs, Post-LPVs; odds ratio [OR] 5.747, 15.000, 207.619, 7.940; P = 0.032, 0.004, 0.034, 0.021) and region length (Post-LPVs; OR 3.183, P = 0.027) were positive predictors of CPVRs, while the mean CF (Ant-RPVs; OR 0.861, P = 0.045) and number of radiofrequency applications per unit length (Ant-LPVs, Post-LPVs; OR 0.038, 0.122; P = 0.034, 0.029) were negative predictors. At optimal cutoffs of 5.8 cm for the region length, 14.2 g for the mean CF, and 1.97/cm (Ant-LPVs) and 2.01/cm (Post-LPVs) for the radiofrequency application density, the sensitivity and specificity were 93.8 and 63.6 %, 60.0 and 76.5 %, 90.0 and 64.1 %, and 75.0 and 63.6 %, respectively. Completing PVI with circumferential lines without touch-up ablation and creating a sufficient density of radiofrequency ablation lesions on the lines with a sufficient CF may be necessary to prevent CPVRs after a CF-guided CPVI.

  15. An assessment of composite repair system in offshore platform for corroded circumferential welds in super duplex steel pipe

    Directory of Open Access Journals (Sweden)

    Silvio de Barros

    2018-04-01

    Full Text Available The main aim of this study is to assess the effectiveness of a composite repair system in severely corroded circumferential welds in super duplex stainless steel pipes as a preventive measure against the premature corrosion damage at the welds. Artificial defects were fabricated on the super duplex steel tube in order to reproduce the localized corrosion damage defects found in real welded joints. Three kinds of through thickness defects were considered: 25%, 50% and 96% of the perimeter of the pipe. The performance of the repaired pipe was assessed by hydrostatic tests as per ISO 24817 standard. The results showed that the composite repair system can sustain the designed failure pressure even for the pipe damaged with through-wall defect up to 96% of the perimeter of the pipe. Hence, the composite repair system can be used as a preliminary tool to protect the unexpected or premature failure at the welds and maintain an adequate level of mechanical strength for a given operating pressure. This composite repair system can assure that the pipe will not leak until a planned maintenance of the line. Nevertheless, further work is still desirable to improve the confidence in the long-term performance of bonded composite

  16. Spatial extent in demographic research - approach and problems

    Directory of Open Access Journals (Sweden)

    Knežević Aleksandar

    2015-01-01

    Full Text Available One of the starting methodological problems in demographic research is the definition of spatial extent, which mostly doesn’t correspond to spatial extent already defined by different levels of administrative-territorial unitsthat are used for distribution of usable statistical data. That’s why determining the spatial extent of a demographic research is closely tied with administrative-territorial division of the territory that is being researched, wherein the fact that differentiation of demographic phenomena and processes cannot be the only basis of setting the principles of regionalization must be strictly acknowledged. This problem is particularly common in historical demographic analyses of geographically determined wholes, which are in administratively-territorial sense represented by one or more smaller territorial units, with their borders changing through the history, which directly affects comparability of the statistical data, and makes it considerably more difficult to track demographic change through longer time intervals. The result of these efforts is usually a solution based on a compromise which enables us to examine the dynamics of population change with little deviation from already defined borders of regional geographic wholes. For that reason in this paper the problem of defining spatial extent in demographic research is examined trough several different approaches in case of Eastern Serbia, as a geographically determined region, a historic area, a spatially functioning whole and as a statistical unit for demographic research, with no judgment calls in regard to any of the regionalization principles. [Projekat Ministarstva nauke Republike Srbije, br. III 47006

  17. Extent of reaction in open systems with multiple heterogeneous reactions

    Science.gov (United States)

    Friedly, John C.

    1991-01-01

    The familiar batch concept of extent of reaction is reexamined for systems of reactions occurring in open systems. Because species concentrations change as a result of transport processes as well as reactions in open systems, the extent of reaction has been less useful in practice in these applications. It is shown that by defining the extent of the equivalent batch reaction and a second contribution to the extent of reaction due to the transport processes, it is possible to treat the description of the dynamics of flow through porous media accompanied by many chemical reactions in a uniform, concise manner. This approach tends to isolate the reaction terms among themselves and away from the model partial differential equations, thereby enabling treatment of large problems involving both equilibrium and kinetically controlled reactions. Implications on the number of coupled partial differential equations necessary to be solved and on numerical algorithms for solving such problems are discussed. Examples provided illustrate the theory applied to solute transport in groundwater flow.

  18. Is Eurasian October snow cover extent increasing?

    International Nuclear Information System (INIS)

    Brown, R D; Derksen, C

    2013-01-01

    A number of recent studies present evidence of an increasing trend in Eurasian snow cover extent (SCE) in the October snow onset period based on analysis of the National Oceanic and Atmospheric Administration (NOAA) historical satellite record. These increases are inconsistent with fall season surface temperature warming trends across the region. Using four independent snow cover data sources (surface observations, two reanalyses, satellite passive microwave retrievals) we show that the increasing SCE is attributable to an internal trend in the NOAA CDR dataset to chart relatively more October snow cover extent over the dataset overlap period (1982–2005). Adjusting the series for this shift results in closer agreement with other independent datasets, stronger correlation with continentally-averaged air temperature anomalies, and a decrease in SCE over 1982–2011 consistent with surface air temperature warming trends over the same period. (letter)

  19. Improved determination of left ventricular volume with myocardial tagging

    International Nuclear Information System (INIS)

    Peshock, R.M.; Takai, H.; Baker, K.V.; Clarke, G.D.; McDonald, G.G.; Parkey, R.W.

    1991-01-01

    Cine MR imaging can be used to determine ventricular volume and ejection fraction. However, definition of the endocardial surface can be difficult, leading some investigators to suggest that black-blood studies are preferable. Grid tagging with use of spatial modulation of magnetization has been used to improve assessments of wall motion. The purpose of this paper, is to determine if grid tagging would also facilitate definition of the endocardial border for volume and ejection fraction calculations. Grid tagging based on spatial modulation of magnetization was implemented on a Toshiba 0.5-T MR imaging device. Standard RAO images were obtained in 10 normal volunteers with use of standard cine MR imaging sequences (33/22) with and without grid tagging. Images were analyzed to determine ventricular volume, cardiac output and wall motion. Images obtained without tagging generally showed good contrast at end diastole, but definition of the endocardial border was frequently more difficult in middle to late systole. Images with tagging provided significantly better definition of endocardial borders, particularly during systole

  20. Ventricular tachycardia in post-myocardial infarction patients. Results of surgical therapy.

    Science.gov (United States)

    Viganò, M; Martinelli, L; Salerno, J A; Minzioni, G; Chimienti, M; Graffigna, A; Goggi, C; Klersy, C; Montemartini, C

    1986-05-01

    This report addresses the problems related to surgical treatment of post-infarction ventricular tachycardia (VT) and is based on a 5 year experience of 36 consecutive patients. In every case the arrhythmia was unresponsive to pharmacological therapy. All patients were operated on after the completion of a diagnostic protocol including preoperative endocardial, intra-operative epi-endocardial mapping, the latter performed automatically when possible. Surgical techniques were: classical Guiraudon's encircling endocardial ventriculotomy (EEV); partial EEV, endocardial resection (ER); cryoablation or a combination of these procedures. The in-hospital mortality (30 days) was 8.3% (3 patients). During the follow-up period (1-68 months), 3 patients (9%) died of cardiac but not VT related causes. Of the survivors, 92% are VT-free. We consider electrophysiologically guided surgery a safe and reliable method for the treatment of post-infarction VT and suggest its more extensive use. We stress the importance of automatic mapping in pleomorphic and non-sustained VT, and the necessity of tailoring the surgical technique to the characteristics of each case.

  1. Identification of Biokinetic Models Using the Concept of Extents.

    Science.gov (United States)

    Mašić, Alma; Srinivasan, Sriniketh; Billeter, Julien; Bonvin, Dominique; Villez, Kris

    2017-07-05

    The development of a wide array of process technologies to enable the shift from conventional biological wastewater treatment processes to resource recovery systems is matched by an increasing demand for predictive capabilities. Mathematical models are excellent tools to meet this demand. However, obtaining reliable and fit-for-purpose models remains a cumbersome task due to the inherent complexity of biological wastewater treatment processes. In this work, we present a first study in the context of environmental biotechnology that adopts and explores the use of extents as a way to simplify and streamline the dynamic process modeling task. In addition, the extent-based modeling strategy is enhanced by optimal accounting for nonlinear algebraic equilibria and nonlinear measurement equations. Finally, a thorough discussion of our results explains the benefits of extent-based modeling and its potential to turn environmental process modeling into a highly automated task.

  2. Benchmarking circumferential resection margin (R1) resection rate for rectal cancer in the neoadjuvant era.

    Science.gov (United States)

    Chambers, W; Collins, G; Warren, B; Cunningham, C; Mortensen, N; Lindsey, I

    2010-09-01

    Circumferential resection margin (CRM) involvement (R1) is used to audit rectal cancer surgical quality. However, when downsizing chemoradiation (dCRT) is used, CRM audits both dCRT and surgery, its use reflecting a high casemix of locally advanced tumours. We aimed to evaluate predictors of R1 and benchmark R1 rates in the dCRT era, and to assess the influence of failure of steps in the multidisciplinary team (MDT) process to CRM involvement. A retrospective analysis of prospectively collected rectal cancer data was undertaken. Patients were classified according to CRM status. Uni- and multivariate analysis was undertaken of risk factors for R1 resection. The contribution of the steps of the MDT process to CRM involvement was assessed. Two hundred and ten rectal cancers were evaluated (68% T3 or T4 on preoperative staging). R1 (microscopic) and R2 (macroscopic) resections occurred in 20 (10%) and 6 patients (3%), respectively. Of several factors associated with R1 resections on univariate analysis, only total mesorectal excision (TME) specimen defects and threatened/involved CRM on preoperative imaging remained as independent predictors of R1 resections on multivariate analysis. Causes of R1 failure by MDT step classification found that less than half were associated with and only 15% solely attributable to a suboptimal TME specimen. Total mesorectal excision specimen defects and staging-predicted threatened or involved CRM are independent strong predictors of R1 resections. In most R1 resections, the TME specimen was intact. It is important to remember the contribution of both the local staging casemix and dCRT failure when using R1 rates to assess purely surgical competence.

  3. Forest extent and deforestation in tropical Africa since 1900.

    Science.gov (United States)

    Aleman, Julie C; Jarzyna, Marta A; Staver, A Carla

    2018-01-01

    Accurate estimates of historical forest extent and associated deforestation rates are crucial for quantifying tropical carbon cycles and formulating conservation policy. In Africa, data-driven estimates of historical closed-canopy forest extent and deforestation at the continental scale are lacking, and existing modelled estimates diverge substantially. Here, we synthesize available palaeo-proxies and historical maps to reconstruct forest extent in tropical Africa around 1900, when European colonization accelerated markedly, and compare these historical estimates with modern forest extent to estimate deforestation. We find that forests were less extensive in 1900 than bioclimatic models predict. Resultantly, across tropical Africa, ~ 21.7% of forests have been deforested, yielding substantially slower deforestation than previous estimates (35-55%). However, deforestation was heterogeneous: West and East African forests have undergone almost complete decline (~ 83.3 and 93.0%, respectively), while Central African forests have expanded at the expense of savannahs (~ 1.4% net forest expansion, with ~ 135,270 km 2 of savannahs encroached). These results suggest that climate alone does not determine savannah and forest distributions and that many savannahs hitherto considered to be degraded forests are instead relatively old. These data-driven reconstructions of historical biome distributions will inform tropical carbon cycle estimates, carbon mitigation initiatives and conservation planning in both forest and savannah systems.

  4. The Geographic Extent of Global Supply Chains

    DEFF Research Database (Denmark)

    Machikita, Tomohiro; Ueki, Yasushi

    2012-01-01

    We study the extent to which inter-firm relationships are locally concentrated and what determines firm differences in geographic proximity to domestic or foreign suppliers and customers. From micro-data on selfreported customer and supplier data of firms in Indonesia, the Philippines, Thailand, ...

  5. Reduced Circumferential Resection Margin Involvement in Rectal Cancer Surgery: Results of the Dutch Surgical Colorectal Audit.

    Science.gov (United States)

    Gietelink, Lieke; Wouters, Michel W J M; Tanis, Pieter J; Deken, Marion M; Ten Berge, Martijn G; Tollenaar, Rob A E M; van Krieken, J Han; de Noo, Mirre E

    2015-09-01

    The circumferential resection margin (CRM) is a significant prognostic factor for local recurrence, distant metastasis, and survival after rectal cancer surgery. Therefore, availability of this parameter is essential. Although the Dutch total mesorectal excision trial raised awareness about CRM in the late 1990s, quality assurance on pathologic reporting was not available until the Dutch Surgical Colorectal Audit (DSCA) started in 2009. The present study describes the rates of CRM reporting and involvement since the start of the DSCA and analyzes whether improvement of these parameters can be attributed to the audit. Data from the DSCA (2009-2013) were analyzed. Reporting of CRM and CRM involvement was plotted for successive years, and variations of these parameters were analyzed in a funnelplot. Predictors of CRM involvement were determined in univariable analysis and the independent influence of year of registration on CRM involvement was analyzed in multivariable analysis. A total of 12,669 patients were included for analysis. The mean percentage of patients with a reported CRM increased from 52.7% to 94.2% (2009-2013) and interhospital variation decreased. The percentage of patients with CRM involvement decreased from 14.2% to 5.6%. In multivariable analysis, the year of DSCA registration remained a significant predictor of CRM involvement. After the introduction of the DSCA, a dramatic improvement in CRM reporting and a major decrease of CRM involvement after rectal cancer surgery have occurred. This study suggests that a national quality assurance program has been the driving force behind these achievements. Copyright © 2015 by the National Comprehensive Cancer Network.

  6. The extent of emphysema in patients with COPD.

    Science.gov (United States)

    Shaker, Saher Burhan; Stavngaard, Trine; Hestad, Marianne; Bach, Karen Skjoelstrup; Tonnesen, Philip; Dirksen, Asger

    2009-01-01

    The global initiative for COPD (GOLD) adopted the degree of airway obstruction as a measure of the severity of the disease. The objective of this study was to apply CT to assess the extent of emphysema in patients with chronic obstructive pulmonary disease (COPD) and relate this extent to the GOLD stage of airway obstruction. We included 209 patients with COPD. COPD was defined as FEV(1)/FVC or=20 pack-years. Patients were assessed by lung function measurement and visual and quantitative assessment of CT, from which the relative area of emphysema below -910 Hounsfield units (RA-910) was extracted. Mean RA-910 was 7.4% (n = 5) in patients with GOLD stage I, 17.0% (n = 119) in stage II, 24.2% (n = 79) in stage III and 33.9% (n = 6) in stage IV. Regression analysis showed a change in RA-910 of 7.8% with increasing severity according to GOLD stage (P < 0.001). Combined visual and quantitative assessment of CT showed that 184 patients had radiological evidence of emphysema, whereas 25 patients had no emphysema. The extent of emphysema increases with increasing severity of COPD and most patients with COPD have emphysema. Tissue destruction by emphysema is therefore an important determinant of disease severity in COPD.

  7. Assessing the Global Extent of Rivers Observable by SWOT

    Science.gov (United States)

    Pavelsky, T.; Durand, M. T.; Andreadis, K.; Beighley, E.; Allen, G. H.; Miller, Z.

    2013-12-01

    Flow of water through rivers is among the key fluxes in the global hydrologic cycle and its knowledge would advance the understanding of flood hazards, water resources management, ecology, and climate. However, gauges providing publicly accessible measurements of river stage or discharge remain sparse in many regions. The Surface Water and Ocean Topography (SWOT) satellite mission is a joint project of NASA and the French Centre National d'Etudes Spatiales (CNES) that would provide the first high-resolution images of simultaneous terrestrial water surface height, inundation extent, and ocean surface elevation. Among SWOT's primary goals is the direct observation of variations in river water surface elevation and, where possible, estimation of river discharge from SWOT measurements. The mission science requirements specify that rivers wider than 100 m would be observed globally, with a goal of observing rivers wider than 50m. However, the extent of anticipated SWOT river observations remains fundamentally unknown because no high-resolution, global dataset of river widths exists. Here, we estimate the global extent of rivers wider than 50 m-100 m thresholds using established relationships among river width, discharge, and drainage area. We combine a global digital elevation model with in situ river discharge data to estimate the global extent of SWOT-observable rivers, and validate these estimates against satellite-derived measurements of river width in two large river basins (the Yukon and the Ohio). We then compare the extent of SWOT-observed rivers with the current publicly-available, global gauge network included in the Global Runoff Data Centre (GRDC) database to examine the impact of SWOT on the availability of river observation over continental and global scales. Results suggest that if SWOT observes 100 m wide rivers, river basins with areas greater than 50,000 km2 will commonly be measured. If SWOT could observe 50 m wide rivers, then most 10,000 km2 basins

  8. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    International Nuclear Information System (INIS)

    Iannicelli, Elsa; Di Renzo, Sara; Ferri, Mario; Pilozzi, Emanuela; Di Girolamo, Marco; Sapori, Alessandra; Ziparo, Vincenzo; David, Vincenzo

    2014-01-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting

  9. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    Energy Technology Data Exchange (ETDEWEB)

    Iannicelli, Elsa; Di Renzo, Sara [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ferri, Mario [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Pilozzi, Emanuela [Department of Clinical and Molecular Sciences, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Di Girolamo, Marco; Sapori, Alessandra [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ziparo, Vincenzo [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); David, Vincenzo [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy)

    2014-07-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting.

  10. Lack of independent significance of a close (<1 mm) circumferential resection margin involvement in esophageal and junctional cancer.

    Science.gov (United States)

    O'Farrell, N J; Donohoe, C L; Muldoon, C; Costelloe, J M; King, S; Ravi, N; Reynolds, J V

    2013-08-01

    For rectal cancer, an involved circumferential resection margin (CRM), defined as tumor cells within 1 mm of the CRM, is of established prognostic significance. This definition for the esophagus, however, is controversial, with the UK Royal College of Pathologists (RCP) recommending the 1 mm definition, while the College of American Pathologists (CAP) advises that only tumor cells at the cut margin (0 mm) define an incomplete (R1) resection. The aim of this study was to compare the clinical significance of both definitions in patients with pT3 tumors. CAP- and RCP-defined CRM status in patients treated by surgery only or by multimodal therapy was recorded prospectively in a comprehensive database from May 2003 to May 2011. Kaplan-Meier survival curves were generated, and factors affecting survival were assessed by univariate and multivariate analysis. A total of 157 of 340 patients had pT3 esophageal tumors, with RCP-positive CRM in 60 %, and 18 % by CAP. There were no significant differences between RCP-positive CRM and negative margins for node-positive disease, local recurrence, and survival. CAP-positive CRM was associated with positive nodes (P = 0.036) and poorer survival (P = 0.023). Multivariate analysis revealed nodal invasion to be the only independent prognostic variable (P = 0.004). A CRM margin of CRM.

  11. High-grade spondylolisthesis: gradual reduction using Magerl's external fixator followed by circumferential fusion technique and long-term results.

    Science.gov (United States)

    Karampalis, Christos; Grevitt, Michael; Shafafy, Masood; Webb, John

    2012-05-01

    To report the results of a cohort of patients treated with this technique high lighting radiological and functional outcomes, discussing also benefits arising from a gradual reduction procedure compared with other techniques. We evaluated nine patients who have undergone high-grade listhesis reduction and circumferential fusion at our institution from 1988 to 2006. Average length of follow-up was 11 years (5-19). Functional outcomes and radiological measurements were recorded and reported. Slip magnitude was reduced by an average of 2.9 grades (Meyerding classification). Slip angle improved by an average of 66% (p = 0.0001), lumbosacral angle by 47% (p = 0.0002), sacral rotation by 51% (p = 0.0068) and sacral inclination by 47% (p = 0.0055). At the latest follow-up 88.9% had achieved solid fusion. Post-operative 10-point Visual Analogue Score (VAS) for back pain had improved by 70% (p Average postoperative Oswestry Disability Index for all patients was 8% (range 0-16%) and that for Low Back Outcome Scores was 56.6 (range 44-70). All components of Short Form 36 Health Survey were greater than 80%. Overall patients' expectations were met in 100%. This is an effective and safe technique which addresses the lumbosacral kyphosis and cosmetic deformity without the neurological complications which accompany other reduction and fusion techniques for high-grade spondylolisthesis.

  12. Fuel rod end plug

    International Nuclear Information System (INIS)

    McGeary, R.K.; Bucher, G.D.

    1989-01-01

    This patent describes an end plug for welded disposition within the end of a tube. It comprises a circumferentially extending, axially oriented land surface, having a radial extent defined by means of a first predetermined dimension, for disposition within the end of the tube; a circumferentially extending, axially oriented land surface, having a radial extent defined by means of a second predetermined dimension which is greater than the first predetermined dimension, for disposition outside of the end of the tube. The second land surface being disposed upstream of the first land surface; an annularly extending, radially oriented shoulder portion, defined at the downstream end of the second land surface and having a radially inward depth which is greater than the difference defined between the first and second radial dimensions of the first and second land surfaces, for engaging the end of the tube in a butt contact fashion; and annular groove means defined between the upstream end of the first land surface and the shoulder portion of the end plug, for eliminating porosity defects normally developed within a weldment defined between the tube end and the end plug when the end plug is welded within the tube end, and including a conical surface which extends radially outwardly from the innermost radial depth extent of the shoulder portion to the upstream end of the first land surface

  13. Effects of geographical extent on the determinants of woody plant diversity

    DEFF Research Database (Denmark)

    Wang, Zhiheng; Rahbek, Carsten; Fang, Jingyun

    2012-01-01

    the quantitative effects of geographical extent are rarely tested. Here, using distribution maps of 11,405 woody species found in China and associated environmental data to the domain, we investigated the influence of geographical extent on the determinants of species richness patterns. Our results revealed...

  14. Modeling of second-harmonic generation of circumferential guided wave propagation in a composite circular tube

    Science.gov (United States)

    Li, Mingliang; Deng, Mingxi; Gao, Guangjian; Xiang, Yanxun

    2018-05-01

    This paper investigated modeling of second-harmonic generation (SHG) of circumferential guided wave (CGW) propagation in a composite circular tube, and then analyzed the influences of interfacial properties on the SHG effect of primary CGW. Here the effect of SHG of primary CGW propagation is treated as a second-order perturbation to its linear wave response. Due to the convective nonlinearity and the inherent elastic nonlinearity of material, there are second-order bulk driving forces and surface/interface driving stresses in the interior and at the surface/interface of a composite circular tube, when a primary CGW mode propagates along its circumference. Based on the approach of modal expansion analysis for waveguide excitation, the said second-order driving forces/stresses are regarded as the excitation sources to generate a series of double-frequency CGW modes that constitute the second-harmonic field of the primary CGW propagation. It is found that the modal expansion coefficient of each double-frequency CGW mode is closely related to the interfacial stiffness constants that are used to describe the interfacial properties between the inner and outer circular parts of the composite tube. Furthermore, changes in the interfacial stiffness constants essentially influence the dispersion relation of CGW propagation. This will remarkably affect the efficiency of cumulative SHG of primary CGW propagation. Some finite element simulations have been implemented of response characteristics of cumulative SHG to the interfacial properties. Both the theoretical analyses and numerical simulations indicate that the effect of cumulative SHG is found to be much more sensitive to changes in the interfacial properties than primary CGW propagation. The potential of using the effect of cumulative SHG by primary CGW propagation to characterize a minor change in the interfacial properties is considered.

  15. Regional Mapping of Plantation Extent Using Multisensor Imagery

    Science.gov (United States)

    Torbick, N.; Ledoux, L.; Hagen, S.; Salas, W.

    2016-12-01

    Industrial forest plantations are expanding rapidly across the tropics and monitoring extent is critical for understanding environmental and socioeconomic impacts. In this study, new, multisensor imagery were evaluated and integrated to extract the strengths of each sensor for mapping plantation extent at regional scales. Three distinctly different landscapes with multiple plantation types were chosen to consider scalability and transferability. These were Tanintharyi, Myanmar, West Kalimantan, Indonesia, and southern Ghana. Landsat-8 Operational Land Imager (OLI), Phased Array L-band Synthetic Aperture Radar-2 (PALSAR-2), and Sentinel-1A images were fused within a Classification and Regression Tree (CART) framework using random forest and high-resolution surveys. Multi-criteria evaluations showed both L-and C-band gamma nought γ° backscatter decibel (dB), Landsat reflectance ρλ, and texture indices were useful for distinguishing oil palm and rubber plantations from other land types. The classification approach identified 750,822 ha or 23% of the Taninathryi, Myanmar, and 216,086 ha or 25% of western West Kalimantan as plantation with very high cross validation accuracy. The mapping approach was scalable and transferred well across the different geographies and plantation types. As archives for Sentinel-1, Landsat-8, and PALSAR-2 continue to grow, mapping plantation extent and dynamics at moderate resolution over large regions should be feasible.

  16. 34 CFR 600.10 - Date, extent, duration, and consequence of eligibility.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 3 2010-07-01 2010-07-01 false Date, extent, duration, and consequence of eligibility... EDUCATION ACT OF 1965, AS AMENDED General § 600.10 Date, extent, duration, and consequence of eligibility... statutory and regulatory requirements governing its eligibility. (e) Consequence of eligibility. (1) If, as...

  17. Comparison of osmotic swelling influences on meniscal fibrocartilage and articular cartilage tissue mechanics in compression and shear.

    Science.gov (United States)

    Nguyen, An M; Levenston, Marc E

    2012-01-01

    Although the contribution of the circumferential collagen bundles to the anisotropic tensile stiffness of meniscal tissue has been well described, the implications of interactions between tissue components for other mechanical properties have not been as widely examined. This study compared the effects of the proteoglycan-associated osmotic swelling stress on meniscal fibrocartilage and articular cartilage (AC) mechanics by manipulating the osmotic environment and tissue compressive offset. Cylindrical samples were obtained from the menisci and AC of bovine stifles, equilibrated in phosphate-buffered saline solutions ranging from 0.1× to 10×, and tested in oscillatory torsional shear and unconfined compression. Biochemical analysis indicated that treatments and testing did not substantially alter tissue composition. Mechanical testing revealed tissue-specific responses to both increasing compressive offset and decreasing bath salinity. Most notably, reduced salinity dramatically increased the shear modulus of both axially and circumferentially oriented meniscal tissue explants to a much greater extent than for cartilage samples. Combined with previous studies, these findings suggest that meniscal proteoglycans have a distinct structural role, stabilizing, and stiffening the matrix surrounding the primary circumferential collagen bundles. Copyright © 2011 Orthopaedic Research Society.

  18. The conservatism of the net-section stress procedure for predicting the failure of cracked piping systems: the effect of crack shape complexity on the degree of conservatism

    International Nuclear Information System (INIS)

    Smith, E.

    1996-01-01

    The failure of circumferentially cracked steel piping is often predicted by assuming that failure conforms to a net-section stress criterion using as input an appropriate value for the critical net-section stress together with a knowledge of the anticipated loadings. The stress at the cracked section is usually calculated via a purely elastic analysis based on the piping being uncracked. however, because the piping is built-in at the ends into a larger component, and since the onset of crack extension requires some plastic deformation, use of the net-section stress approach can give overly conservative failure predictions. In earlier work, the author has quantified the extent of this conservatism, and has shown how it depends on the geometry of the cracked section, the material ductility and the elastic flexibility of a piping system. This paper quantifies the conservatism with regard to the case where a through-wall crack extends over a prescribed fraction of the pipe circumference, while there is also an internal circumferential crack extending around the remainder of the pipe section. This is an extreme form of circumferential cracking but nevertheless, simulates the well-known Duane Arnold safe-end crack. (Author)

  19. Fast Simulation of Mechanical Heterogeneity in the Electrically Asynchronous Heart Using the MultiPatch Module.

    Directory of Open Access Journals (Sweden)

    John Walmsley

    2015-07-01

    Full Text Available Cardiac electrical asynchrony occurs as a result of cardiac pacing or conduction disorders such as left bundle-branch block (LBBB. Electrically asynchronous activation causes myocardial contraction heterogeneity that can be detrimental for cardiac function. Computational models provide a tool for understanding pathological consequences of dyssynchronous contraction. Simulations of mechanical dyssynchrony within the heart are typically performed using the finite element method, whose computational intensity may present an obstacle to clinical deployment of patient-specific models. We present an alternative based on the CircAdapt lumped-parameter model of the heart and circulatory system, called the MultiPatch module. Cardiac walls are subdivided into an arbitrary number of patches of homogeneous tissue. Tissue properties and activation time can differ between patches. All patches within a wall share a common wall tension and curvature. Consequently, spatial location within the wall is not required to calculate deformation in a patch. We test the hypothesis that activation time is more important than tissue location for determining mechanical deformation in asynchronous hearts. We perform simulations representing an experimental study of myocardial deformation induced by ventricular pacing, and a patient with LBBB and heart failure using endocardial recordings of electrical activation, wall volumes, and end-diastolic volumes. Direct comparison between simulated and experimental strain patterns shows both qualitative and quantitative agreement between model fibre strain and experimental circumferential strain in terms of shortening and rebound stretch during ejection. Local myofibre strain in the patient simulation shows qualitative agreement with circumferential strain patterns observed in the patient using tagged MRI. We conclude that the MultiPatch module produces realistic regional deformation patterns in the asynchronous heart and that

  20. The effect of exercise training on left ventricular function in young elite athletes

    Directory of Open Access Journals (Sweden)

    De Luca Alessio

    2011-10-01

    Full Text Available Abstract Background Regular training, in particular endurance exercise, induces structural myocardial adaptation, so-called "athlete's heart". In addition to the 2D standard echo parameters, assessment of myocardial function is currently possible by deformation parameters (strain, rotation and twist. Aim of study is to assess the role of rotation and twist parameters for better characterize the heart performance in trained elite young athletes from different kind of sports. Eventually, verify early on any possible impact due to the regular sport activity not revealed by the standard parameters. Methods 50 young athletes (16 cyclists, 17 soccer players, 17 basket players regularly trained at least three times a week for at least 9 months a year and 10 young controls (mean age 18.5 ± 0.5 years were evaluated either by to 2D echocardiography or by a Speckle Tracking (ST multi-layer approach to calculate Left Ventricle (LV endocardial and epicardial rotation, twist, circumferential strain (CS and longitudinal strain (LS. Data were compared by ANOVA test. Results All the found values were within the normal range. Left Ventricle Diastolic Diameter (LVDD 51.7 ± 2.6 mm, Cardiac Mass index (CMi 114.5 ± 18.5 g/m2, epi-CS, epi-LS, epicardial apex rotation and the Endo/Epi twist were significantly higher only in cyclists. In all the groups, a physiological difference of the Endo/Epi basal circumferential strain and twist values have been found. A weak but not significant relationship between the Endo and twist values and LVDD (r2 = 0.44, p = .005 and CMi was also reported in cyclists. Conclusions Progressive increase of apical LV twist may represent an important component of myocardial remodelling. This aspect is particularly evident in the young cyclists group where the CMi and the LVDD are higher. ST multilayer approach completes the LV performance evaluation in young trained athletes showing values similar to adults.

  1. Correlation between left ventricular filling and ischemic extent during exercise-induced myocardial ischemia

    International Nuclear Information System (INIS)

    Ando, Akitada; Yokota, Mitsuhiro; Iwase, Mitsunori

    1993-01-01

    The aim of this study was to determine how the extent of exercise-induced myocardial ischemia influence left ventricular filling. Twenty-two consecutive patients with effort angina, consisting of 16 with single vessel disease and 6 with double vessel disease, underwent exercise studies in lying and sitting positions. Extent score (ES) and severity score (SS) were calculated on polar map prepared from early exercise Tl-201 myocardial SPECT images to determine ischemic extent. Pulmonary arterial wedge pressure (PAWP), as obtained at exercise in lying position, correlated significantly well with both ES (r=0.75, p<0.001) and SS (r=0.61, p<0.01). There was, however, no significant correlation between the other hemodynamic parameters, such as heart rate, systolic pressure, rate-pressure product, cardiac index and stroke index, and both ES and SS. Either increased PAWP or ischemic extent was not dependent on the number of diseased vessels. In conclusion, the extent of increased left ventricular filling did not correlate with the number of diseased vessels, but correlated positively with ischemic extent. (N.K.)

  2. Computerized analysis of the 12-lead electrocardiogram to identify epicardial ventricular tachycardia exit sites.

    Science.gov (United States)

    Yokokawa, Miki; Jung, Dae Yon; Joseph, Kim K; Hero, Alfred O; Morady, Fred; Bogun, Frank

    2014-11-01

    Twelve-lead electrocardiogram (ECG) criteria for epicardial ventricular tachycardia (VT) origins have been described. In patients with structural heart disease, the ability to predict an epicardial origin based on QRS morphology is limited and has been investigated only for limited regions in the heart. The purpose of this study was to determine whether a computerized algorithm is able to accurately differentiate epicardial vs endocardial origins of ventricular arrhythmias. Endocardial and epicardial pace-mapping were performed in 43 patients at 3277 sites. The 12-lead ECGs were digitized and analyzed using a mixture of gaussian model (MoG) to assess whether the algorithm was able to identify an epicardial vs endocardial origin of the paced rhythm. The MoG computerized algorithm was compared to algorithms published in prior reports. The computerized algorithm correctly differentiated epicardial vs endocardial pacing sites for 80% of the sites compared to an accuracy of 42% to 66% of other described criteria. The accuracy was higher in patients without structural heart disease than in those with structural heart disease (94% vs 80%, P = .0004) and for right bundle branch block (82%) compared to left bundle branch block morphologies (79%, P = .001). Validation studies showed the accuracy for VT exit sites to be 84%. A computerized algorithm was able to accurately differentiate the majority of epicardial vs endocardial pace-mapping sites. The algorithm is not region specific and performed best in patients without structural heart disease and with VTs having a right bundle branch block morphology. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  3. Usefulness of Epicardial Area in the Short Axis to Identify Elevated Left Ventricular Mass in Men.

    Science.gov (United States)

    Fitzpatrick, Jesse K; Cohen, Beth E; Rosenblatt, Andrew; Shaw, Richard E; Schiller, Nelson B

    2018-06-15

    Left ventricular (LV) hypertrophy is strongly associated with increased cardiovascular morbidity and mortality. The 2-dimensional LV mass algorithms suffer from measurement variability that can lead to misclassification of patients with LV hypertrophy as normal, or vice versa. Among the 4 echocardiographic measurements required by the 2-dimensional LV mass algorithms, epicardial and endocardial area have the lowest interobserver variation and could be used to corroborate LV mass calculations. We sought cut-off values that are able to discriminate between elevated and normal LV mass based on endocardial or epicardial area alone. Using data from 664 men enrolled in the Mind Your Heart Study, we calculated the correlation of LV mass index with epicardial area and endocardial area. We then used receiver operator characteristic curves to identify epicardial and endocardial area cut-points that could discriminate subjects with normal LV mass and LV hypertrophy. LV mass index was more strongly correlated with epicardial area compared with endocardial area, r = 0.70 versus r = 0.27, respectively. Epicardial area had a significantly higher area under the receiver operator characteristic curve (p versus 0.63 (95% confidence interval 0.57 to 0.71). An epicardial area cut-point of ≥38.0 cm 2 corresponded to a sensitivity of 95.0% and specificity of 54.4% for detecting LV hypertrophy. In conclusion, epicardial area showed promise as a method of rapid screening for LV hypertrophy and could be used to validate formal LV mass calculations. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. What is the significance of the circumferential margin in locally advanced rectal cancer after neoadjuvant chemoradiotherapy?

    Science.gov (United States)

    Trakarnsanga, Atthaphorn; Gonen, Mithat; Shia, Jinru; Goodman, Karyn A; Nash, Garrett M; Temple, Larissa K; Guillem, José G; Paty, Philip B; Garcia-Aguilar, Julio; Weiser, Martin R

    2013-04-01

    The circumferential resection margin (CRM) is highly prognostic for local recurrence in rectal cancer surgery without neoadjuvant treatment. However, its significance in the setting of long-course neoadjuvant chemoradiotherapy (nCRT) is not well defined. Review of a single institution's prospectively maintained database from 1998 to 2007 identified 563 patients with locally advanced rectal cancer (T3/T4 and/or N1) receiving nCRT, followed after 6 weeks by total mesorectal excision (TME). Kaplan-Meier, Cox regression, and competing risk analysis were performed. The authors noted that 75 % of all patients had stage III disease as determined by endorectal ultrasound (ERUS) and/or magnetic resonance imaging (MRI). With median follow-up of 39 months after resection, local and distant relapse were noted in 12 (2.1 %) and 98 (17.4 %) patients, respectively. On competing risk analysis, the optimal cutoff point of CRM was 1 mm for local recurrence and 2 mm for distant metastasis. Factors independently associated with local recurrence included CRM ≤1 mm, and high-grade tumor (p = 0.012 and 0.007, respectively). CRM ≤2 mm, as well as pathological, nodal, and overall tumor stage are also significant independent risk factors for distant metastasis (p = 0.025, 0.010, and dataset of locally advanced rectal cancer treated with nCRT followed by TME, CRM ≤1 mm is an independent risk factor for local recurrence and is considered a positive margin. CRM ≤2 mm was associated with distant recurrence, independent of pathological tumor and nodal stage.

  5. 27 CFR 24.158 - Extent of relief.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Extent of relief. 24.158 Section 24.158 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT..., until all tax is fully paid. (d) Wine vinegar plant bond. The surety will be relieved of liability for...

  6. Extent, accuracy, and credibility of breastfeeding information on the Internet.

    Science.gov (United States)

    Shaikh, Ulfat; Scott, Barbara J

    2005-05-01

    Our objective was to test and describe a model for evaluating Websites related to breastfeeding. Forty Websites most likely to be accessed by the public were evaluated for extent, accuracy, credibility, presentation, ease of use, and adherence to ethical and medical Internet publishing standards. Extent and accuracy of Website content were determined by a checklist of critical information. The majority of Websites reviewed provided accurate information and complied with the International Code of Marketing of Breast-milk Substitutes. Approximately half the Websites complied with standards of medical Internet publishing. While much information on breastfeeding on the Internet is accurate, there is wide variability in the extent of information, usability of Websites, and compliance with standards of medical Internet publishing. Results of this study may be helpful to health care professionals as a model for evaluating breastfeeding-related Websites and to highlight considerations when recommending or designing Websites.

  7. 32 CFR 728.12 - Extent of care.

    Science.gov (United States)

    2010-07-01

    ... § 728.12 Extent of care. Members who are away from their duty stations or are on duty where there is no... providing authorization for non-Federal care at DHHS expense. (b) Maternity episode for active duty female... facilities (once the mother has been admitted to the USMTF) from funds available for care of active duty...

  8. Exploring the Origin, Extent, and Future of Life

    Science.gov (United States)

    Bertka, Constance M.

    2009-09-01

    1. Astrobiology in societal context Constance Bertka; Part I. Origin of Life: 2. Emergence and the experimental pursuit of the origin of life Robert Hazen; 3. From Aristotle to Darwin, to Freeman Dyson: changing definitions of life viewed in historical context James Strick; 4. Philosophical aspects of the origin-of-life problem: the emergence of life and the nature of science Iris Fry; 5. The origin of terrestrial life: a Christian perspective Ernan McMullin; 6. The alpha and the omega: reflections on the origin and future of life from the perspective of Christian theology and ethics Celia Deane-Drummond; Part II. Extent of Life: 7. A biologist's guide to the Solar System Lynn Rothschild; 8. The quest for habitable worlds and life beyond the Solar System Carl Pilcher; 9. A historical perspective on the extent and search for life Steven J. Dick; 10. The search for extraterrestrial life: epistemology, ethics, and worldviews Mark Lupisella; 11. The implications of discovering extraterrestrial life: different searches, different issues Margaret S. Race; 12. God, evolution, and astrobiology Cynthia S. W. Crysdale; Part III. Future of Life: 13. Planetary ecosynthesis on Mars: restoration ecology and environmental ethics Christopher P. McKay; 14. The trouble with intrinsic value: an ethical primer for astrobiology Kelly C. Smith; 15. God's preferential option for life: a Christian perspective on astrobiology Richard O. Randolph; 16. Comparing stories about the origin, extent, and future of life: an Asian religious perspective Francisca Cho; Index.

  9. Sparing Sphincters and Laparoscopic Resection Improve Survival by Optimizing the Circumferential Resection Margin in Rectal Cancer Patients.

    Science.gov (United States)

    Keskin, Metin; Bayraktar, Adem; Sivirikoz, Emre; Yegen, Gülcin; Karip, Bora; Saglam, Esra; Bulut, Mehmet Türker; Balik, Emre

    2016-02-01

    The goal of rectal cancer treatment is to minimize the local recurrence rate and extend the disease-free survival period and survival. For this aim, obtainment of negative circumferential radial margin (CRM) plays an important role. This study evaluated predictive factors for positive CRM status and its effect on patient survival in mid- and distal rectal tumors.Patients who underwent curative resection for rectal cancer were included. The main factors were demographic data, tumor location, surgical technique, neoadjuvant therapy, tumor diameter, tumor depth, lymph node metastasis, mesorectal integrity, CRM, the rate of local recurrence, distant metastasis, and overall and disease-free survival. Statistical analyses were performed by using the Chi-squared test, Fisher exact test, Student t test, Mann-Whitney U test and the Mantel-Cox log-rank sum test.A total of 420 patients were included, 232 (55%) of whom were male. We observed no significant differences in patient characteristics or surgical treatment between the patients who had positive CRM and who had negative CRM, but a higher positive CRM rate was observed in patients undergone abdominoperineal resection (APR) (P CRM status. Logistic regression analysis revealed that APR (P CRM status. Moreover, positive CRM was associated with decreased 5-year overall and disease-free survival (P = 0.002 and P = 0.004, respectively).This large single-institution series demonstrated that APR and open resection were independent predictive factors for positive CRM status in rectal cancer. Positive CRM independently decreased the 5-year overall and disease-free survival rates.

  10. The extent of emphysema in patients with COPD

    DEFF Research Database (Denmark)

    Shaker, Saher Burhan; Stavngaard, Trine; Hestad, Marianne

    2009-01-01

    BACKGROUND AND AIMS: The global initiative for COPD (GOLD) adopted the degree of airway obstruction as a measure of the severity of the disease. The objective of this study was to apply CT to assess the extent of emphysema in patients with chronic obstructive pulmonary disease (COPD) and relate...... measurement and visual and quantitative assessment of CT, from which the relative area of emphysema below -910 Hounsfield units (RA-910) was extracted. RESULTS: Mean RA-910 was 7.4% (n = 5) in patients with GOLD stage I, 17.0% (n = 119) in stage II, 24.2% (n = 79) in stage III and 33.9% (n = 6) in stage IV....... Regression analysis showed a change in RA-910 of 7.8% with increasing severity according to GOLD stage (P emphysema, whereas 25 patients had no emphysema. CONCLUSION: The extent of emphysema...

  11. Research Misconduct—Definitions, Manifestations and Extent

    Directory of Open Access Journals (Sweden)

    Lutz Bornmann

    2013-10-01

    Full Text Available In recent years, the international scientific community has been rocked by a number of serious cases of research misconduct. In one of these, Woo Suk Hwang, a Korean stem cell researcher published two articles on research with ground-breaking results in Science in 2004 and 2005. Both articles were later revealed to be fakes. This paper provides an overview of what research misconduct is generally understood to be, its manifestations and the extent to which they are thought to exist.

  12. Atrial fibrillation driven by micro-anatomic intramural re-entry revealed by simultaneous sub-epicardial and sub-endocardial optical mapping in explanted human hearts.

    Science.gov (United States)

    Hansen, Brian J; Zhao, Jichao; Csepe, Thomas A; Moore, Brandon T; Li, Ning; Jayne, Laura A; Kalyanasundaram, Anuradha; Lim, Praise; Bratasz, Anna; Powell, Kimerly A; Simonetti, Orlando P; Higgins, Robert S D; Kilic, Ahmet; Mohler, Peter J; Janssen, Paul M L; Weiss, Raul; Hummel, John D; Fedorov, Vadim V

    2015-09-14

    The complex architecture of the human atria may create physical substrates for sustained re-entry to drive atrial fibrillation (AF). The existence of sustained, anatomically defined AF drivers in humans has been challenged partly due to the lack of simultaneous endocardial-epicardial (Endo-Epi) mapping coupled with high-resolution 3D structural imaging. Coronary-perfused human right atria from explanted diseased hearts (n = 8, 43-72 years old) were optically mapped simultaneously by three high-resolution CMOS cameras (two aligned Endo-Epi views (330 µm2 resolution) and one panoramic view). 3D gadolinium-enhanced magnetic resonance imaging (GE-MRI, 80 µm3 resolution) revealed the atrial wall structure varied in thickness (1.0 ± 0.7-6.8 ± 2.4 mm), transmural fiber angle differences, and interstitial fibrosis causing transmural activation delay from 23 ± 11 to 43 ± 22 ms at increased pacing rates. Sustained AF (>90 min) was induced by burst pacing during pinacidil (30-100 µM) perfusion. Dual-sided sub-Endo-sub-Epi optical mapping revealed that AF was driven by spatially and temporally stable intramural re-entry with 107 ± 50 ms cycle length and transmural activation delay of 67 ± 31 ms. Intramural re-entrant drivers were captured primarily by sub-Endo mapping, while sub-Epi mapping visualized re-entry or 'breakthrough' patterns. Re-entrant drivers were anchored on 3D micro-anatomic tracks (15.4 ± 2.2 × 6.0 ± 2.3 mm2, 2.9 ± 0.9 mm depth) formed by atrial musculature characterized by increased transmural fiber angle differences and interstitial fibrosis. Targeted radiofrequency ablation of the tracks verified these re-entries as drivers of AF. Integrated 3D structural-functional mapping of diseased human right atria ex vivo revealed that the complex atrial microstructure caused significant differences between Endo vs. Epi activation during pacing and sustained AF driven by intramural re-entry anchored to fibrosis-insulated atrial bundles. Published on

  13. Circumferential welding applied for inox steel super duplex UNS S32750 using the process MIG using CMT® control

    International Nuclear Information System (INIS)

    Invernizzi, Bruno Pizol

    2017-01-01

    This study carried out circumferential welding experiments in UNS S32750 Super Duplex Stainless Steel tubes using diameters of 19,05 mm and 48,20 mm. Welds were performed using various welding parameters on a MIG machine with Cold Metal Transfer® CMT control. The weld joints were evaluated by visual and dimensional inspection in addition to the Vickers microhardness and traction tests, as well as the microstructural analysis in conjunction with phase precipitation analysis, which was performed according to practice A of ASTM A923, and corrosion test in accordance with practice A of ASTM G48 in conjunction with ASTM A923. The results indicated that welds performed in pipes with a diameter of 19.05 mm showed a weld joint with unacceptable dimensions according to the standard, this condition being attributed the use of a high wire diameter for the welding conditions used. Welding performed for pipes with a diameter of 48.20 mm showed a lack of penetration under the conditions employed when welded by the conventional CMT® process. In the case of the use of CMT® combined with pulsed arc, under conditions that generated greater heat input during welding, this resulted in total penetration of the joint and adequate surface finish. The results indicated that welding using the CMT® process combined with pulsed arc, under the conditions (parameters) employed generated good surface finish, combined mechanical properties, meeting standards requirements, as well as a balanced microstructure and high resistance to corrosion. (author)

  14. Studies on the behavior of part-through circumferential crack at intrados in elbows under in-plane bending moment

    International Nuclear Information System (INIS)

    Srivastava, A.; Prabhakaran, K.M.; Ghosh, A.K.

    2011-01-01

    Highlights: → Behavior of cracked elbows with part-through crack at intrados under bending moment is studied. → Some part of crack always opens and some part gets closed irrespective of mode of applied moment. → Fraction of the crack that opens basically decides the weakening effect of the cracked elbow. → Results will be useful for fracture studies and limit load estimation especially for LBB. - Abstract: This paper presents the behavior of part-through circumferential crack at intrados in elbows under in-plane bending moment. This is based on detailed non-linear (both material and geometric) finite element analysis performed on various sizes of elbows (generally used in piping industry), having different crack sizes. It is observed that some part of the crack always opens and some part gets closed irrespective of the mode of applied bending moment (opening/closing). The fraction of the crack that opens basically decides the weakening effect of the cracked elbow. It is observed that there is a threshold value of crack length and crack depth, before which no crack opening is observed under opening mode. Also as elbow becomes thinner, the threshold value of above two parameters increases. Quite interestingly, the part of crack which closes in opening mode opens under closing mode. The above mentioned study on the behavior of crack will be useful for fracture studies and limit load estimation especially when leak before break concept is to be employed.

  15. Capturing heterogeneity: The role of a study area's extent for estimating mean throughfall

    Science.gov (United States)

    Zimmermann, Alexander; Voss, Sebastian; Metzger, Johanna Clara; Hildebrandt, Anke; Zimmermann, Beate

    2016-11-01

    The selection of an appropriate spatial extent of a sampling plot is one among several important decisions involved in planning a throughfall sampling scheme. In fact, the choice of the extent may determine whether or not a study can adequately characterize the hydrological fluxes of the studied ecosystem. Previous attempts to optimize throughfall sampling schemes focused on the selection of an appropriate sample size, support, and sampling design, while comparatively little attention has been given to the role of the extent. In this contribution, we investigated the influence of the extent on the representativeness of mean throughfall estimates for three forest ecosystems of varying stand structure. Our study is based on virtual sampling of simulated throughfall fields. We derived these fields from throughfall data sampled in a simply structured forest (young tropical forest) and two heterogeneous forests (old tropical forest, unmanaged mixed European beech forest). We then sampled the simulated throughfall fields with three common extents and various sample sizes for a range of events and for accumulated data. Our findings suggest that the size of the study area should be carefully adapted to the complexity of the system under study and to the required temporal resolution of the throughfall data (i.e. event-based versus accumulated). Generally, event-based sampling in complex structured forests (conditions that favor comparatively long autocorrelations in throughfall) requires the largest extents. For event-based sampling, the choice of an appropriate extent can be as important as using an adequate sample size.

  16. Testing of VVER reactor pressure vessels by TOFD method

    International Nuclear Information System (INIS)

    Skala, Z.; Vit, J.

    2002-01-01

    The Time of Flight Diffraction Method (TOFD) - one of the new testing methods capable to obtain the real dimensions of flaws - is presented in the paper.The laboratory experiments on samples with artificial flaws and samples with artificially prepared cracks confirmed the high accuracy of flaw through wall extent sizing by TOFD. This accuracy was confirmed by qualification of methods and systems used by Skoda JS for the in-service inspections of WWER 440 vessel circumferential weld. The qualification also confirmed the ability of TOFD to detect reliably flaws, which can are not reliably detected by standard pulse echo testing. Based on the result of experiments and qualification, the TOFD method shall be used routinely by Skoda JS for the inspection of vessel circumferential welds root area and for sizing of flaws exceeding the acceptance level

  17. Left ventricular functional, structural and energetic effects of normal aging: Comparison with hypertension.

    Directory of Open Access Journals (Sweden)

    Jehill D Parikh

    Full Text Available Both aging and hypertension are significant risk factors for heart failure in the elderly. The purpose of this study was to determine how aging, with and without hypertension, affects left ventricular function.Cross-sectional study of magnetic resonance imaging and 31P spectroscopy-based measurements of left ventricular structure, global function, strains, pulse wave velocity, high energy phosphate metabolism in 48 normal subjects and 40 treated hypertensive patients (though no other cardiovascular disease or diabetes stratified into 3 age deciles from 50-79 years.Normal aging was associated with significant increases in systolic blood pressure, vascular stiffness, torsion, and impaired diastolic function (all P<0.05. Age-matched hypertension exacerbated the effects of aging on systolic pressure, and diastolic function. Hypertension alone, and not aging, was associated with increased left ventricular mass index, reduced energetic reserve, reduced longitudinal shortening and increased endocardial circumferential shortening (all P<0.05. Multiple linear regression analysis showed that these unique hypertensive features were significantly related to systolic blood pressure (P<0.05.1 Hypertension adds to the age-related changes in systolic blood pressure and diastolic function; 2 hypertension is uniquely associated with changes in several aspects of left ventricular structure, function, systolic strains, and energetics; and 3 these uniquely hypertensive-associated parameters are related to the level of systolic blood pressure and so are potentially modifiable.

  18. The Extent of Reversibility of Polychlorinated Biphenyl Adsorption

    Science.gov (United States)

    The extent of reversibility of PCB bonding to sediments has been characterized in studies on the partitioning behavior of a hexachlorobiphenyl isomer. Linear non-singular isotherms have been observed for the adsorption and desorption of 2.4.5.2?,4?,5? hexachlorobiphenyl (HCBP) to...

  19. The extent of forest in dryland biomes

    Science.gov (United States)

    Jean-Francois Bastin; Nora Berrahmouni; Alan Grainger; Danae Maniatis; Danilo Mollicone; Rebecca Moore; Chiara Patriarca; Nicolas Picard; Ben Sparrow; Elena Maria Abraham; Kamel Aloui; Ayhan Atesoglu; Fabio Attore; Caglar Bassullu; Adia Bey; Monica Garzuglia; Luis G. GarcÌa-Montero; Nikee Groot; Greg Guerin; Lars Laestadius; Andrew J. Lowe; Bako Mamane; Giulio Marchi; Paul Patterson; Marcelo Rezende; Stefano Ricci; Ignacio Salcedo; Alfonso Sanchez-Paus Diaz; Fred Stolle; Venera Surappaeva; Rene Castro

    2017-01-01

    Dryland biomes cover two-fifths of Earth’s land surface, but their forest area is poorly known. Here, we report an estimate of global forest extent in dryland biomes, based on analyzing more than 210,000 0.5-hectare sample plots through a photo-interpretation approach using large databases of satellite imagery at (i) very high spatial resolution and (ii) very high...

  20. Accuracy of determining preoperative cancer extent measured by automated breast ultrasonography.

    Science.gov (United States)

    Tozaki, Mitsuhiro; Fukuma, Eisuke

    2010-12-01

    The aim of this study was to determine the accuracy of measuring preoperative cancer extent using automated breast ultrasonography (US). This retrospective study consisted of 40 patients with histopathologically confirmed breast cancer. All of the patients underwent automated breast US (ABVS; Siemens Medical Solutions, Mountain View, CA, USA) on the day before the surgery. The sizes of the lesions on US were measured on coronal multiplanar reconstruction images using the ABVS workstation. Histopathological measurement of tumor size included not only the invasive foci but also any in situ component and was used as the gold standard. The discrepancy of the tumor extent between automated breast US and the histological examination was calculated. Automated breast US enabled visualization of the breast carcinomas in all patients. The mean size of the lesions on US was 12 mm (range 4-62 mm). The histopathological diagnosis was ductal carcinoma in situ (DCIS) in seven patients and invasive ductal carcinoma in 33 patients (18 without an intraductal component, 15 with an intraductal component). Lesions ranged in diameter from 4 to 65 mm (mean 16 mm). The accuracy of determination of the tumor extent with a deviation in length of <2 cm was 98% (39/40). Automated breast US is thought to be useful for evaluating tumor extent preoperatively.

  1. Northern Alaskan land surface response to reduced Arctic sea ice extent

    Energy Technology Data Exchange (ETDEWEB)

    Higgins, Matthew E. [University of Colorado, Cooperative Institute for Research in Environmental Sciences, Boulder, CO (United States); Cassano, John J. [University of Colorado, Cooperative Institute for Research in Environmental Sciences, Department of Atmospheric and Oceanic Sciences, Boulder, CO (United States)

    2012-05-15

    With Arctic sea ice extent at near-record lows, an improved understanding of the relationship between sea ice and the land surface is warranted. We examine the land surface response to changing sea ice by first conducting a simulation using the Community Atmospheric Model version 3.1 with end of the twenty-first century sea ice extent. This future atmospheric response is then used to force the Weather and Research Forecasting Model version 3.1 to examine the terrestrial land surface response at high resolution over the North Slope of Alaska. Similar control simulations with twentieth century sea ice projections are also performed, and in both simulations only sea ice extent is altered. In the future sea ice extent experiment, atmospheric temperature increases significantly due to increases in latent and sensible heat flux, particularly in the winter season. Precipitation and snow pack increase significantly, and the increased snow pack contributes to warmer soil temperatures for most seasons by insulating the land surface. In the summer, however, soil temperatures are reduced due to increased albedo. Despite warmer near-surface atmospheric temperatures, it is found that spring melt is delayed throughout much of the North Slope due to the increased snow pack, and the growing season length is shortened. (orig.)

  2. Combined Circumferential and Longitudinal Left Ventricular Systolic Dysfunction in Patients with Rheumatoid Arthritis without Overt Cardiac Disease.

    Science.gov (United States)

    Cioffi, Giovanni; Viapiana, Ombretta; Ognibeni, Federica; Dalbeni, Andrea; Gatti, Davide; Mazzone, Carmine; Faganello, Giorgio; Di Lenarda, Andrea; Adami, Silvano; Rossini, Maurizio

    2016-07-01

    Patients with rheumatoid arthritis have an increased risk for cardiovascular disease. Because of accelerated atherosclerosis and changes in left ventricular (LV) geometry, circumferential and longitudinal (C&L) LV systolic dysfunction (LVSD) may be impaired in these patients despite preserved LV ejection fraction. The aim of this study was to determine the prevalence of and factors associated with combined C&L LVSD in patients with rheumatoid arthritis. One hundred ninety-eight outpatients with rheumatoid arthritis without overt cardiac disease were prospectively analyzed from January through June 2014 and compared with 198 matched control subjects. C&L systolic function was evaluated by stress-corrected midwall shortening (sc-MS) and tissue Doppler mitral annular peak systolic velocity (S'). Combined C&L LVSD was defined if sc-MS was cite either of them in the other one and, afterward, we just did not think about this point anymore. Of note, the idea to combine in the analysis longitudinal function came therefore well after the starting process of revision of the paper E and was, in some way inspired by a reviewer's comment. That is why we did not put both findings in the same paper. We think that our explanations provide the broad audience of your journal a perspective of transparency and our respect for the readers' right to understand how the work described in the paper J relates to other work by our research group. Giovanni Cioffi On behalf of all co-authors Ombretta Viapiana, Federica Ognibeni, Andrea Dalbeni, Davide Gatti, Carmine Mazzone, Giorgio Faganello, Andrea Di Lenarda, Silvano Adami, and Maurizio Rossini. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  3. Valvular Disorders in Carcinoid Heart Disease

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    Full Text Available Abstract Carcinoid heart disease is a rare but important cause of intrinsic right heart valve disorders leading to right heart failure. Occasionally, left-sided heart valves may also be involved. The characteristic cardiac pathological findings of carcinoid heart disease are endocardial thickening as a result of fibrous deposits on the endocardium. Echocardiographic examination and right heart catheterization are very useful for the diagnosis of the lesion. If more cardiac valves are affected, multiple valve replacement should be considered. The management of the pulmonary valve lesion depends on the extent of the diseased valve, either by valvulotomy, valvectomy, or valve replacement. Percutaneous valve implantations in the pulmonary and in the inferior vena cava positions have been advocated for high-risk patients.

  4. Factors influencing the spatial extent of mobile source air pollution impacts: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Levy Jonathan I

    2007-05-01

    Full Text Available Abstract Background There has been growing interest among exposure assessors, epidemiologists, and policymakers in the concept of "hot spots", or more broadly, the "spatial extent" of impacts from traffic-related air pollutants. This review attempts to quantitatively synthesize findings about the spatial extent under various circumstances. Methods We include both the peer-reviewed literature and government reports, and focus on four significant air pollutants: carbon monoxide, benzene, nitrogen oxides, and particulate matter (including both ultrafine particle counts and fine particle mass. From the identified studies, we extracted information about significant factors that would be hypothesized to influence the spatial extent within the study, such as the study type (e.g., monitoring, air dispersion modeling, GIS-based epidemiological studies, focus on concentrations or health risks, pollutant under study, background concentration, emission rate, and meteorological factors, as well as the study's implicit or explicit definition of spatial extent. We supplement this meta-analysis with results from some illustrative atmospheric dispersion modeling. Results We found that pollutant characteristics and background concentrations best explained variability in previously published spatial extent estimates, with a modifying influence of local meteorology, once some extreme values based on health risk estimates were removed from the analysis. As hypothesized, inert pollutants with high background concentrations had the largest spatial extent (often demonstrating no significant gradient, and pollutants formed in near-source chemical reactions (e.g., nitrogen dioxide had a larger spatial extent than pollutants depleted in near-source chemical reactions or removed through coagulation processes (e.g., nitrogen oxide and ultrafine particles. Our illustrative dispersion model illustrated the complex interplay of spatial extent definitions, emission rates

  5. Extent of implementation of Collection Development Policies (CDP ...

    African Journals Online (AJOL)

    The study was on the extent of implementation of collection development policies by public University libraries in the Niger Delta Area, Nigeria. Descriptive survey design was employed. Population for the study consisted of all the 16 Colle ction Development Librarians in the Area studied. No sample was used because the ...

  6. Extent of implementation of collection development policies in ...

    African Journals Online (AJOL)

    The study is a survey research on the extent of implementation of collection development policies in academic libraries in Imo state. The population of the study comprises five (5) academic libraries in the area of study. The academic libraries understudy are: Imo State University Owerri (IMSU), Federal University of ...

  7. Analysis of fuel rod behaviour within a rod bundle of a pressurized water reactor under the conditions of a loss of coolant accident (LOCA) using probabilistic methodology

    International Nuclear Information System (INIS)

    Sengpiel, W.

    1980-12-01

    The assessment of fuel rod behaviour under PWR LOCA conditions aims at the evaluation of the peak cladding temperatures and the (final) maximum circumferential cladding strains. Moreover, the estimation of the amount of possible coolant channel blockages within a rod bundle is of special interest, as large coplanar clad strains of adjacent rods may result in strong local reductions of coolant channel areas. Coolant channel blockages of large radial extent may impair the long-term coolability of the corresponding rods. A model has been developed to describe these accident consequences using probabilistic methodology. This model is applied to study the behaviour of fuel rods under accident conditions following the double-ended pipe rupture between collant pump and pressure vessel in the primary system of a 1300 MW(el)-PWR. Specifically a rod bundle is considered consisting of 236 fuel rods, that is subjected to severe thermal and mechanical loading. The results obtained indicate that plastic clad deformations with circumferential clad strains of more than 30% cannot be excluded for hot rods of the reference bundle. However, coplanar coolant channel blockages of significant extent seem to be probable within that bundle only under certain boundary conditions which are assumed to be pessimistic. (orig./RW) [de

  8. Mapping US Urban Extents from MODIS Data Using One-Class Classification Method

    Directory of Open Access Journals (Sweden)

    Bo Wan

    2015-08-01

    Full Text Available Urban areas are one of the most important components of human society. Their extents have been continuously growing during the last few decades. Accurate and timely measurements of the extents of urban areas can help in analyzing population densities and urban sprawls and in studying environmental issues related to urbanization. Urban extents detected from remotely sensed data are usually a by-product of land use classification results, and their interpretation requires a full understanding of land cover types. In this study, for the first time, we mapped urban extents in the continental United States using a novel one-class classification method, i.e., positive and unlabeled learning (PUL, with multi-temporal Moderate Resolution Imaging Spectroradiometer (MODIS data for the year 2010. The Defense Meteorological Satellite Program Operational Linescan System (DMSP-OLS night stable light data were used to calibrate the urban extents obtained from the one-class classification scheme. Our results demonstrated the effectiveness of the use of the PUL algorithm in mapping large-scale urban areas from coarse remote-sensing images, for the first time. The total accuracy of mapped urban areas was 92.9% and the kappa coefficient was 0.85. The use of DMSP-OLS night stable light data can significantly reduce false detection rates from bare land and cropland far from cities. Compared with traditional supervised classification methods, the one-class classification scheme can greatly reduce the effort involved in collecting training datasets, without losing predictive accuracy.

  9. Extent of resection and timing of surgery in adult low grade glioma.

    Science.gov (United States)

    A Mirza, Farhan; Shamim, Muhammad Shahzad

    2017-06-01

    Low grade glioma is a group of WHO grade II tumours including diffuse astrocytoma, oligodendroglioma, and oligoastrocytoma. Strong evidence exists in literature now to support early surgery and higher extent of safe resection in improving outcomes. In this review, we are highlighting some of the important studies done in the last few years specifically addressing timing of surgery and extent of resection.

  10. Successes and challenges from formation to implementation of eleven broad-extent conservation programs.

    Science.gov (United States)

    Beever, Erik A; Mattsson, Brady J; Germino, Matthew J; Burg, Max Post Van Der; Bradford, John B; Brunson, Mark W

    2014-04-01

    Integration of conservation partnerships across geographic, biological, and administrative boundaries is increasingly relevant because drivers of change, such as climate shifts, transcend these boundaries. We explored successes and challenges of established conservation programs that span multiple watersheds and consider both social and ecological concerns. We asked representatives from a diverse set of 11 broad-extent conservation partnerships in 29 countries 17 questions that pertained to launching and maintaining partnerships for broad-extent conservation, specifying ultimate management objectives, and implementation and learning. Partnerships invested more funds in implementing conservation actions than any other aspect of conservation, and a program's context (geographic extent, United States vs. other countries, developed vs. developing nation) appeared to substantially affect program approach. Despite early successes of these organizations and benefits of broad-extent conservation, specific challenges related to uncertainties in scaling up information and to coordination in the face of diverse partner governance structures, conflicting objectives, and vast uncertainties regarding future system dynamics hindered long-term success, as demonstrated by the focal organizations. Engaging stakeholders, developing conservation measures, and implementing adaptive management were dominant challenges. To inform future research on broad-extent conservation, we considered several challenges when we developed detailed questions, such as what qualities of broad-extent partnerships ensure they complement, integrate, and strengthen, rather than replace, local conservation efforts and which adaptive management processes yield actionable conservation strategies that account explicitly for dynamics and uncertainties regarding multiscale governance, environmental conditions, and knowledge of the system? © 2014 Society for Conservation Biology.

  11. A method for determining the extent of thermal burns in elephants

    Directory of Open Access Journals (Sweden)

    A. Shakespeare

    2006-06-01

    Full Text Available A practical method was developed to assess the extent of burns suffered by elephants caught in bush fires. In developing this method, the surface areas of the different body parts of juvenile, subadult and adult elephants were first determined using standard equations, and then expressed as a percentage of the total body surface area. When viewed from a distance, the burnt proportion of all body segments is estimated, converted to percentages of total body surface area, and then summed to determine the extent of burns suffered.

  12. Monitoring the Extent of Forests on National to Global Scales

    Science.gov (United States)

    Townshend, J.; Townshend, J.; Hansen, M.; DeFries, R.; DeFries, R.; Sohlberg, R.; Desch, A.; White, B.

    2001-05-01

    Information on forest extent and change is important for many purposes, including understanding the global carbon cycle and managing natural resources. International statistics on forest extent are generated using many different sources often producing inconsistent results spatially and through time. Results will be presented comparing forest extent derived from the recent global Food and Agricultural Organization's (FAO) FRA 2000 report with products derived using wall-to-wall Landsat, AVHRR and MODIS data sets. The remotely sensed data sets provide consistent results in terms of total area despite considerable differences in spatial resolution. Although the location of change can be satisfactorily detected with all three remotely sensed data sets, reliable measurement of change can only be achieved through use of Landsat-resolution data. Contrary to the FRA 2000 results we find evidence of an increase in deforestation rates in the late 1990s in several countries. Also we have found evidence of considerable changes in some countries for which little or no change is reported by FAO. The results indicate the benefits of globally consistent analyses of forest cover based on multiscale remotely sensed data sets rather than a reliance on statistics generated by individual countries with very different definitions of forest and methods used to derive them.

  13. Extent of pyrolysis impacts on fast pyrolysis biochar properties.

    Science.gov (United States)

    Brewer, Catherine E; Hu, Yan-Yan; Schmidt-Rohr, Klaus; Loynachan, Thomas E; Laird, David A; Brown, Robert C

    2012-01-01

    A potential concern about the use of fast pyrolysis rather than slow pyrolysis biochars as soil amendments is that they may contain high levels of bioavailable C due to short particle residence times in the reactors, which could reduce the stability of biochar C and cause nutrient immobilization in soils. To investigate this concern, three corn ( L.) stover fast pyrolysis biochars prepared using different reactor conditions were chemically and physically characterized to determine their extent of pyrolysis. These biochars were also incubated in soil to assess their impact on soil CO emissions, nutrient availability, microorganism population growth, and water retention capacity. Elemental analysis and quantitative solid-state C nuclear magnetic resonance spectroscopy showed variation in O functional groups (associated primarily with carbohydrates) and aromatic C, which could be used to define extent of pyrolysis. A 24-wk incubation performed using a sandy soil amended with 0.5 wt% of corn stover biochar showed a small but significant decrease in soil CO emissions and a decrease in the bacteria:fungi ratios with extent of pyrolysis. Relative to the control soil, biochar-amended soils had small increases in CO emissions and extractable nutrients, but similar microorganism populations, extractable NO levels, and water retention capacities. Corn stover amendments, by contrast, significantly increased soil CO emissions and microbial populations, and reduced extractable NO. These results indicate that C in fast pyrolysis biochar is stable in soil environments and will not appreciably contribute to nutrient immobilization. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  14. Evaluation of diagnostic efficiency of intelligence program for automatic diagnosis of circumferential profiles of myocardial short axial SPECT

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Tada, Akira; Nakajima, Kenichi; Taki, Junichi; Kojima, Kazuhiko.

    1984-01-01

    Quantitative diagnosis using circumferential profile (CFP) is widely employed for Tl-201 myocardial imaging. However, its diagnostic efficiency is susceptible to the number and composition of the confirmed normal (CN) group. Intelligence program for CFP data file and automatic diagnosis (CAD), which was previously developed by us, was modified for creating universal data file (d-base) and evaluated its diagnostic efficiency for myocardial short axial images according to the number of CNs. CAD consists of following 3 major functions: (1) CFP data filing to d-base, (2) modification and correction of file data, and (3) automatic diagnosis of CFP. When function (1) or (2) is completed, new diagnostic criteria (mean-2 sd) are generated automatically using CN data in the d-base at that time. Because of this function, diagnostic criteria are changeable according to the number of CNs. Sensitivity (TP) and specificity (TN) of CAD program for Tl-201 7-pinhole images of 16 normals and 17 ischemic heart diseases (IHDs) were 100%, 44% (CN = 4), 88%, 94% (CN = 8 or 16) and 88%, 100% (CN = 12), respectively. Diagnostic efficiency reached plateau in more than 8 CNs. Although number of patients were limited (8 CNs and 6 IHDs), results of CAD for short axial SPECT showed consistent tendency with 7-pinhole images. In conclusion, intelligence program is necessary for automatic diagnosis using quantitative criteria under the clinical condition of daily increasing informations. Automatic diagnosis of CFP using CAD program is simple, effective and useful for interpretation of Tl-201 myocardial short axial images. CAD program is applicable to any quantitative distribution study using CFPs. (author)

  15. Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

    Science.gov (United States)

    Trott, C M; Ouyang, J; El Fakhri, G

    2010-11-21

    Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest (99m)Tc-sestamibi/(123)I-BMIPP imaging protocol in place of the commonly used sequential rest/stress (99m)Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.

  16. Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects

    International Nuclear Information System (INIS)

    Trott, C M; Ouyang, J; El Fakhri, G

    2010-01-01

    Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest 99m Tc-sestamibi/ 123 I-BMIPP imaging protocol in place of the commonly used sequential rest/stress 99m Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.

  17. Effect of Emphysema Extent on Serial Lung Function in Patients with Idiopathic Pulmonary Fibrosis.

    Science.gov (United States)

    Cottin, Vincent; Hansell, David M; Sverzellati, Nicola; Weycker, Derek; Antoniou, Katerina M; Atwood, Mark; Oster, Gerry; Kirchgaessler, Klaus-Uwe; Collard, Harold R; Wells, Athol U

    2017-11-01

    Patients with idiopathic pulmonary fibrosis and emphysema may have artificially preserved lung volumes. In this post hoc analysis, we investigated the relationship between baseline emphysema and fibrosis extents, as well as pulmonary function changes, over 48 weeks. Data were pooled from two phase III, randomized, double-blind, placebo-controlled trials of IFN-γ-1b in idiopathic pulmonary fibrosis (GIPF-001 [NCT00047645] and GIPF-007 [NCT00075998]). Patients with Week 48 data, baseline high-resolution computed tomographic images, and FEV 1 /FVC ratios less than 0.8 or greater than 0.9 (0.9 in GIPF-007), as well as randomly selected patients with ratios of 0.8-0.9 and 0.7-0.8, were included. Changes from baseline in pulmonary function at Week 48 were analyzed by emphysema extent. The relationship between emphysema and fibrosis extents and change in pulmonary function was assessed using multivariate linear regression. Emphysema was identified in 38% of patients. A negative correlation was observed between fibrosis and emphysema extents (r = -0.232; P emphysema extent (28 to 65%) showed the smallest FVC decline, with a difference of 3.32% at Week 48 versus patients with no emphysema (P = 0.047). In multivariate analyses, emphysema extent greater than or equal to 15% was associated with significantly reduced FVC decline over 48 weeks versus no emphysema or emphysema less than 15%. No such association was observed for diffusing capacity of the lung for carbon monoxide or composite physiologic index. FVC measurements may not be appropriate for monitoring disease progression in patients with idiopathic pulmonary fibrosis and emphysema extent greater than or equal to 15%.

  18. Prediction of fracture parameters of circumferential through-wall cracks in the interface between an elbow and a pipe under internal pressure

    International Nuclear Information System (INIS)

    Jang, Youn Young; Huh, Nam Su; Jeong, Jae Uk

    2016-01-01

    This paper provides plastic influence functions of GE/EPRI method for calculating J and Crack opening displacement (COD) of pipes with a circumferential Through-wall crack (TWC) in the interface between an elbow and a straight pipe by using 3-dimensional (3-D) elastic-plastic finite element analyses for Ramberg-Osgood (R-O) materials, in which internal pressure was considered as a loading condition. The proposed plastic influence functions are tabulated as a function of the pipe geometries, crack length and strain hardening exponent. In order to provide sufficient confidence for the proposed plastic influence functions, the estimation scheme using the proposed plastic influence functions for J and COD of cracked elbows was validated against FE results using R-O parameters for the SA312 TP316 stainless steel. Moreover, the predicted J and COD for elbows with a TWC in the interface between an elbow and a pipe by the proposed scheme were compared with those for cracked straight pipes to investigate the effect of the elbow geometries on crack behavior of elbows. One important point is that crack behaviors in the interface between an elbow and a straight pipe can be significantly different with those in straight pipes according to pipe thickness, crack length and bend radius of elbows. Thus, the proposed plastic influence functions can be useful to predict accurate J and COD for cracked elbows

  19. Prediction of fracture parameters of circumferential through-wall cracks in the interface between an elbow and a pipe under internal pressure

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Youn Young; Huh, Nam Su [Dept. of Mechanical System Design Engineering, Seoul National Univ. of Science and Technology, Seoul (Korea, Republic of); Jeong, Jae Uk [Doosan Heavy Industries and Construction, Changwon (Korea, Republic of)

    2016-09-15

    This paper provides plastic influence functions of GE/EPRI method for calculating J and Crack opening displacement (COD) of pipes with a circumferential Through-wall crack (TWC) in the interface between an elbow and a straight pipe by using 3-dimensional (3-D) elastic-plastic finite element analyses for Ramberg-Osgood (R-O) materials, in which internal pressure was considered as a loading condition. The proposed plastic influence functions are tabulated as a function of the pipe geometries, crack length and strain hardening exponent. In order to provide sufficient confidence for the proposed plastic influence functions, the estimation scheme using the proposed plastic influence functions for J and COD of cracked elbows was validated against FE results using R-O parameters for the SA312 TP316 stainless steel. Moreover, the predicted J and COD for elbows with a TWC in the interface between an elbow and a pipe by the proposed scheme were compared with those for cracked straight pipes to investigate the effect of the elbow geometries on crack behavior of elbows. One important point is that crack behaviors in the interface between an elbow and a straight pipe can be significantly different with those in straight pipes according to pipe thickness, crack length and bend radius of elbows. Thus, the proposed plastic influence functions can be useful to predict accurate J and COD for cracked elbows.

  20. Safety and effectiveness of a circumferential clip-based vascular closure device for hemostasis in off-label applications: Comparison with standard applications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Chan; Kim, Chang Won [Dept. of Radiology, Pusan National University School of Medicine, Pusan National University Hospital, Busan (Korea, Republic of); Jeon, Ung Bae [Dept. of Radiology, Pusan National University School of Medicine, Yangsan Pusan National University Hospital, Yangsan (Korea, Republic of)

    2016-09-15

    We investigated the efficacy and safety of a circumferential nitinol clip based arterial closure device following arteriotomy, especially in off-label applications. Consecutive patients who underwent the procedure with arteriotomy from January 2011 to February 2014 were included in this study. We defined standard use as the use of StarClose for retrograde puncture of the common femoral artery (CFA) and off-label use as the use of StarClose for retrograde puncture of the superficial femoral artery (SFA), antegrade puncture of the CFA or SFA, puncture of the brachial artery or puncture of the vascular graft. The procedures performed included percutaneous transluminal angioplasty and thrombolysis. Technical success was defined as complete hemostasis achieved within 3 minute after the closure. Complications, and laboratory findings associated with coagulation function, were also investigated. There were 146 cases of standard applications and 111 cases of off-label applications. Technical success was achieved in all cases. The off-label group comprised the use of StarClose for retrograde puncture of the SFA (n = 19), antegrade puncture of the CFA or SFA (n = 74), brachial artery puncture (n = 5), larger sheath than 6 Fr (n = 7) and vascular graft puncture (n = 6). Minor complications were noted in both groups (standard group: 7.5%, off-label group: 2.7%). Off-label use of StarClose is safe and feasible.

  1. Safety and effectiveness of a circumferential clip-based vascular closure device for hemostasis in off-label applications: Comparison with standard applications

    International Nuclear Information System (INIS)

    Lee, Seung Chan; Kim, Chang Won; Jeon, Ung Bae

    2016-01-01

    We investigated the efficacy and safety of a circumferential nitinol clip based arterial closure device following arteriotomy, especially in off-label applications. Consecutive patients who underwent the procedure with arteriotomy from January 2011 to February 2014 were included in this study. We defined standard use as the use of StarClose for retrograde puncture of the common femoral artery (CFA) and off-label use as the use of StarClose for retrograde puncture of the superficial femoral artery (SFA), antegrade puncture of the CFA or SFA, puncture of the brachial artery or puncture of the vascular graft. The procedures performed included percutaneous transluminal angioplasty and thrombolysis. Technical success was defined as complete hemostasis achieved within 3 minute after the closure. Complications, and laboratory findings associated with coagulation function, were also investigated. There were 146 cases of standard applications and 111 cases of off-label applications. Technical success was achieved in all cases. The off-label group comprised the use of StarClose for retrograde puncture of the SFA (n = 19), antegrade puncture of the CFA or SFA (n = 74), brachial artery puncture (n = 5), larger sheath than 6 Fr (n = 7) and vascular graft puncture (n = 6). Minor complications were noted in both groups (standard group: 7.5%, off-label group: 2.7%). Off-label use of StarClose is safe and feasible

  2. Assessing the extent of bone degradation using glutamine deamidation in collagen.

    Science.gov (United States)

    Wilson, Julie; van Doorn, Nienke L; Collins, Matthew J

    2012-11-06

    Collagen peptides are analyzed using a low-cost, high-throughput method for assessing deamidation using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). For each chosen peptide, the theoretical distribution is calculated and the measured distribution for each sample compared with this to determine the extent of glutamine deamidation. The deamidation of glutamine (Q) to glutamic acid (E) results in a mass shift of +0.984 Da. Thus, from the resolution of our data, the second peak in the isotope distribution for a peptide containing one glutamine residue coincides with the first peak of the isotope distribution for the peptide in which the residue is deamidated. A genetic algorithm is used to determine the extent of deamidation that gives the best fit to the measured distribution. The method can be extended to peptides containing more than one glutamine residue. The extent of protein degradation assessed in this way could be used, for example, to assess the damage of collagen, and screen samples for radiocarbon dating and DNA analysis.

  3. Efficacy of helical CT in evaluating local tumor extent of breast cancer

    International Nuclear Information System (INIS)

    Ozaki, Yutaka

    2001-01-01

    The purpose of this study is to clarify the diagnostic accuracy of helical CT (HCT) in the determination of local tumor extent of breast cancer. One hundred forty consecutive patients with breast cancer, including 87 invasive ductal carcinomas without extensive intraductal components (EIC), 44 invasive ductal carcinomas with EIC, 2 non-invasive ductal carcinomas, and 7 invasive lobular carcinomas, were included in the study. Three-dimensional tumor diameter including whole extent was measured on HCT, and the amount of invasion to fat tissue, skin, pectoral muscle, and chest wall was estimated using a three-step scale. These results were then compared with the pathological findings. Breast cancers appeared as areas of high attenuation compared with the surrounding breast tissue in all patients. Tumor extent was correctly diagnosed by HCT to within a maximum difference of 1 cm in 88 patients (63%) and within 2 cm in 122 patients (87%). Sensitivity, specificity, and accuracy in diagnosing muscular invasion of breast cancer using HCT were 100%, 99%, and 99%, respectively. Sensitivity, specificity, and accuracy in diagnosing skin invasion of breast cancer using HCT were 84%, 93%, and 91%, respectively. HCT was able to visualize all of the tumors and detect the correct tumor extent in most patients. (author)

  4. Efficacy of helical CT in evaluating local tumor extent of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Yutaka [Juntendo Univ., Chiba (Japan). Urayasu Hospital

    2001-04-01

    The purpose of this study is to clarify the diagnostic accuracy of helical CT (HCT) in the determination of local tumor extent of breast cancer. One hundred forty consecutive patients with breast cancer, including 87 invasive ductal carcinomas without extensive intraductal components (EIC), 44 invasive ductal carcinomas with EIC, 2 non-invasive ductal carcinomas, and 7 invasive lobular carcinomas, were included in the study. Three-dimensional tumor diameter including whole extent was measured on HCT, and the amount of invasion to fat tissue, skin, pectoral muscle, and chest wall was estimated using a three-step scale. These results were then compared with the pathological findings. Breast cancers appeared as areas of high attenuation compared with the surrounding breast tissue in all patients. Tumor extent was correctly diagnosed by HCT to within a maximum difference of 1 cm in 88 patients (63%) and within 2 cm in 122 patients (87%). Sensitivity, specificity, and accuracy in diagnosing muscular invasion of breast cancer using HCT were 100%, 99%, and 99%, respectively. Sensitivity, specificity, and accuracy in diagnosing skin invasion of breast cancer using HCT were 84%, 93%, and 91%, respectively. HCT was able to visualize all of the tumors and detect the correct tumor extent in most patients. (author)

  5. Intrafamiliar clinical variability of circumferential skin creases Kunze type caused by a novel heterozygous mutation of N-terminal TUBB gene.

    Science.gov (United States)

    Dentici, M L; Terracciano, A; Bellacchio, E; Capolino, R; Novelli, A; Digilio, M C; Dallapiccola, B

    2018-02-10

    Circumferential skin creases Kunze type (CSC-KT; OMIM 156610, 616734) is a rare disorder characterized by folding of excess skin, which leads to ringed creases, known as Michelin Tire Baby Syndrome (MTBS). CSC-KT patients also exhibit facial dysmorphism, growth retardation, intellectual disability (ID) and multiple congenital malformations. Recently, 2 heterozygous mutations in TUBB gene and 4 mutations (both homozygous and heterozygous) in MAPRE2 gene were identified in 3 and 4 CSC-KT patients, respectively. In the 3 TUBB gene-related CSC-KT patients, all mutations fall in the N-terminal gene domain and were de novo. Mutations in the C-terminal of TUBB gene have been associated to microcephaly and structural brain malformation, in the absence of CSC-KT features. We report a 9-year-old boy with a diagnosis of CSC-KT based on MTBS, facial dysmorphism, microcephaly, severe ID, cortical atrophy and corpus callosum hypoplasia. Sanger sequencing identified a novel heterozygous c.218T>C (p.Met73Thr) mutation in the N-terminal of TUBB gene, that was inherited from the mother affected by isolated MTBS. This is the first report of inherited TUBB gene-related CSC-KT resulting from a novel heterozygous mutation in the N-terminal domain. Present data support the role of TUBB mutations in CSC-KT and definitely includes CSC-KT syndrome within the tubulinopathies. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Prognostic significance of cancer within 1 mm of the circumferential resection margin in oesophageal cancer patients following neo-adjuvant chemotherapy.

    Science.gov (United States)

    Salih, Tamir; Jose, Paul; Mehta, Samir P; Mirza, Ahmed; Udall, Gavin; Pritchard, Susan A; Hayden, Jeremy D; Grabsch, Heike I

    2013-03-01

    The prognostic significance of the circumferential resection margin (CRM) status in oesophageal cancer patients treated with neo-adjuvant chemotherapy and radical resection is controversial. Furthermore, it is currently unclear whether patients with cancer located at the CRM have a prognosis different from that of those with cancer within 1 mm of the CRM. This is the first study aiming to establish the optimal tumour-free distance from the CRM of an oesophagectomy in patients who have undergone neo-adjuvant chemotherapy. The clinicopathological data of 232 oesophageal cancer patients from two UK centres were analysed. The CRM status was classified as Group A (cancer at the CRM), Group B (cancer within 1 mm but not at the CRM) and Group C (no cancer within 1 mm from the CRM). The relationship between the CRM status and patient survival was investigated. Thirty-eight specimens were classified as Group A, 89 as Group B and 105 as Group C. CRM status was related to the depth of tumour invasion (P CRM or within 1 mm of the CRM of the resected specimen have a significantly worse survival than patients with no cancer cells within 1 mm of the margin. However, this study suggests that the overall prognostic significance of the CRM status is limited in this cohort and the postoperative lymph node status is the most important prognostic factor in oesophageal cancer patients treated with neo-adjuvant chemotherapy and surgery.

  7. Extent of hippocampal atrophy predicts degree of deficit in recall.

    Science.gov (United States)

    Patai, Eva Zita; Gadian, David G; Cooper, Janine M; Dzieciol, Anna M; Mishkin, Mortimer; Vargha-Khadem, Faraneh

    2015-10-13

    Which specific memory functions are dependent on the hippocampus is still debated. The availability of a large cohort of patients who had sustained relatively selective hippocampal damage early in life enabled us to determine which type of mnemonic deficit showed a correlation with extent of hippocampal injury. We assessed our patient cohort on a test that provides measures of recognition and recall that are equated for difficulty and found that the patients' performance on the recall tests correlated significantly with their hippocampal volumes, whereas their performance on the equally difficult recognition tests did not and, indeed, was largely unaffected regardless of extent of hippocampal atrophy. The results provide new evidence in favor of the view that the hippocampus is essential for recall but not for recognition.

  8. An essay on the extent and significance of the Greek athletic culture in the classical period

    DEFF Research Database (Denmark)

    Nielsen, Thomas Heine

    2014-01-01

    This article discusses the extent of the Greek athletic culture in the classical period. It is demonstrated that the athletic culture had a surprising extent, and the article goes on the discuss the historical significance of this fact.......This article discusses the extent of the Greek athletic culture in the classical period. It is demonstrated that the athletic culture had a surprising extent, and the article goes on the discuss the historical significance of this fact....

  9. Effects of circumferential ankle pressure on ankle proprioception, stiffness, and postural stability: a preliminary investigation.

    Science.gov (United States)

    You, Sung H; Granata, Kevin P; Bunker, Linda K

    2004-08-01

    Cross-sectional repeated-measures design. Determine the effects of circumferential ankle pressure (CAP) intervention on proprioceptive acuity, ankle stiffness, and postural stability. The application of CAP using braces, taping, and adaptive shoes or military boots is widely used to address chronic ankle instability (CAI). An underlying assumption is that the CAP intervention might improve ankle stability through increased proprioceptive acuity and stiffness in the ankle. METHOD AND MEASURES: A convenience sample of 10 subjects was recruited from the local university community and categorized according to proprioceptive acuity (high, low) and ankle stability (normal, CAI). Proprioceptive acuity was measured when blindfolded subjects were asked to accurately reproduce a self-selected target ankle position before and after the application of CAP. Proprioceptive acuity was determined in 5 different ankle joint position sense tests: neutral, inversion, eversion, plantar flexion, and dorsiflexion. Joint position angles were recorded electromechanically using a potentiometer. Passive ankle stiffness was computed from the ratio of applied static moment versus angular displacement. Active ankle stiffness was determined from biomechanical analyses of ankle motion following a mediolateral perturbation. Postural stability was quantified from the center of pressure displacement in the mediolateral and the anteroposterior directions in unipedal stance. All measurements were recorded with and without CAP applied by a pediatric blood pressure cuff. Data were analyzed using a separate mixed-model analysis of variance (ANOVA) for each dependent variable. Post hoc comparison using Tukey's honestly significant difference (HSD) test was performed if significant interactions were obtained. Significance level was set at P<.05 for all analyses. Significant group (high versus low proprioceptive acuity) x CAP interactions were identified for postural stability. Passive ankle stiffness was

  10. To what extent can the nuclear public relations be effective?

    International Nuclear Information System (INIS)

    Ohnishi, Teruaki

    1996-01-01

    The effect of public relations (PRs) on the public's attitude to nuclear energy was assessed using a model developed under the assumption that the extent of attitude change of the public by the PRs activity is essentially the same as that by the nuclear information released by the newsmedia. The attitude change of the public was quantitatively estimated by setting variables explicitly manifesting the activities such as the circulation of exclusive publicity and the area of advertising messages in the newspaper as parameters. The public's attitude became clear to have a nonlinear dependence on the amount of activity, the extent of its change being varied considerably with demographic classes. Under a given financial condition, the offer of PRs information to the people, as many as possible in a target region, in spite of its little force of appeal, was found to be more effective for the amelioration of public attitude than the repeated offer of the information to a limited member of the public. It also became clear that there exists the most effective media mix for the activity depending on the extent of target region and on the target class of demography, therefore, it is quite significant to determine beforehand the proper conditions for the activity to be executed, such a situation indicating the need for the introduction of nuclear PRs management. (Author)

  11. To what extent can the nuclear public relations be effective?

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Teruaki [CRC Research Institute, Tokyo (Japan)

    1996-06-01

    The effect of public relations (PRs) on the public`s attitude to nuclear energy was assessed using a model developed under the assumption that the extent of attitude change of the public by the PRs activity is essentially the same as that by the nuclear information released by the newsmedia. The attitude change of the public was quantitatively estimated by setting variables explicitly manifesting the activities such as the circulation of exclusive publicity and the area of advertising messages in the newspaper as parameters. The public`s attitude became clear to have a nonlinear dependence on the amount of activity, the extent of its change being varied considerably with demographic classes. Under a given financial condition, the offer of PRs information to the people, as many as possible in a target region, in spite of its little force of appeal, was found to be more effective for the amelioration of public attitude than the repeated offer of the information to a limited member of the public. It also became clear that there exists the most effective media mix for the activity depending on the extent of target region and on the target class of demography, therefore, it is quite significant to determine beforehand the proper conditions for the activity to be executed, such a situation indicating the need for the introduction of nuclear PRs management. (Author).

  12. Does Trust Influence the Extent of Inter-Organizational Barter?

    DEFF Research Database (Denmark)

    Sudzina, Frantisek

    2014-01-01

    The 1999 World Business Environment Survey investigated, among many other things, the extent of inter-organizational barter in various countries. Reported values differed a lot, e.g. it was less than 1% in Hungary but more than 30% in neighboring Croatia. Since in many such contracts goods and...

  13. An investigation into Nigerian teacher's attitude towards and extent ...

    African Journals Online (AJOL)

    The attitude of Biology teachers towards and their extent of improvisation, were investigated 80 teachers from 50 randomly selected secondary schools in Oyo state of Nigeria participated in the study. Analysis of the twenty item questionnaire administered to the teachers revealed that though many of them exhibited positive ...

  14. Extent and Distribution of Groundwater Resources in Parts of ...

    African Journals Online (AJOL)

    The extent and distribution of groundwater resources in parts of Anambra State, Nigeria has been investigated. The results show that the study area is directly underlain by four different geological formations including, Alluvial Plain Sands, Ogwashi-Asaba Formation, Ameki/Nanka Sands and Imo Shale, with varying water ...

  15. Determining wetland spatial extent and seasonal variations of the ...

    African Journals Online (AJOL)

    This study, done in the Witbank Dam Catchment in Mpumalanga Province of South Africa, explores a remote-sensing technique to delineate wetland extent and assesses the seasonal variations of the inundated area. The objective was to monitor the spatio-temporal changes of wetlands over time through remote sensing ...

  16. The Extent of computerization in big companies of the Spanish hotel sector

    OpenAIRE

    Infante Moro, Alfonso; Martínez López, Francisco José; Infante Moro, Juan Carlos

    2015-01-01

    This is the first study of the hotel sector regarding the extent of computerization in its big companies. This study examines the extent of computerization in big companies of the Spanish hotel sector with the aim of confirming the viability and sustainability of this sector relative to changes in ICT, a stage which is defined by the extensive use of the Internet and online social networks, and the handling of large quantities of information generated within these new env...

  17. Automated Snow Extent Mapping Based on Orthophoto Images from Unmanned Aerial Vehicles

    Science.gov (United States)

    Niedzielski, Tomasz; Spallek, Waldemar; Witek-Kasprzak, Matylda

    2018-04-01

    The paper presents the application of the k-means clustering in the process of automated snow extent mapping using orthophoto images generated using the Structure-from-Motion (SfM) algorithm from oblique aerial photographs taken by unmanned aerial vehicle (UAV). A simple classification approach has been implemented to discriminate between snow-free and snow-covered terrain. The procedure uses the k-means clustering and classifies orthophoto images based on the three-dimensional space of red-green-blue (RGB) or near-infrared-red-green (NIRRG) or near-infrared-green-blue (NIRGB) bands. To test the method, several field experiments have been carried out, both in situations when snow cover was continuous and when it was patchy. The experiments have been conducted using three fixed-wing UAVs (swinglet CAM by senseFly, eBee by senseFly, and Birdie by FlyTech UAV) on 10/04/2015, 23/03/2016, and 16/03/2017 within three test sites in the Izerskie Mountains in southwestern Poland. The resulting snow extent maps, produced automatically using the classification method, have been validated against real snow extents delineated through a visual analysis and interpretation offered by human analysts. For the simplest classification setup, which assumes two classes in the k-means clustering, the extent of snow patches was estimated accurately, with areal underestimation of 4.6% (RGB) and overestimation of 5.5% (NIRGB). For continuous snow cover with sparse discontinuities at places where trees or bushes protruded from snow, the agreement between automatically produced snow extent maps and observations was better, i.e. 1.5% (underestimation with RGB) and 0.7-0.9% (overestimation, either with RGB or with NIRRG). Shadows on snow were found to be mainly responsible for the misclassification.

  18. Successes and challenges from formation to implementation of eleven broad-extent conservation programs

    Science.gov (United States)

    Beever, Erik A.; Bradford, John B.; Germino, Matthew J.; Mattsson, Brady J.; Post van der Burg, Max; Brunson, Mark

    2014-01-01

    Integration of conservation partnerships across geographic, biological, and administrative boundaries is increasingly relevant because drivers of change, such as climate shifts, transcend these boundaries. We explored successes and challenges of established conservation programs that span multiple watersheds and consider both social and ecological concerns. We asked representatives from a diverse set of 11 broadextent conservation partnerships in 29 countries 17 questions that pertained to launching and maintaining partnerships for broad-extent conservation, specifying ultimate management objectives, and implementation and learning. Partnerships invested more funds in implementing conservation actions than any other aspect of conservation, and a program’s context (geographic extent, United States vs. other countries, developed vs. developing nation) appeared to substantially affect program approach. Despite early successes of these organizations and benefits of broad-extent conservation, specific challenges related to uncertainties in scaling up information and to coordination in the face of diverse partner governance structures, conflicting objectives, and vast uncertainties regarding future system dynamics hindered long-term success, as demonstrated by the focal organizations. Engaging stakeholders, developing conservation measures, and implementing adaptive management were dominant challenges. To inform future research on broad-extent conservation, we considered several challenges when we developed detailed questions, such as what qualities of broad-extent partnerships ensure they complement, integrate, and strengthen, rather than replace, local conservation efforts and which adaptive management processes yield actionable conservation strategies that account explicitly for dynamics and uncertainties regarding multiscale governance, environmental conditions, and knowledge of the system?

  19. Detecting the Extent of Eutectoid Transformation in U-10Mo

    International Nuclear Information System (INIS)

    Devaraj, Arun; Jana, Saumyadeep; McInnis, Colleen A.; Lombardo, Nicholas J.; Joshi, Vineet V.; Sweet, Lucas E.; Manandhar, Sandeep; Lavender, Curt A.

    2016-01-01

    During eutectoid transformation of U-10Mo alloy, uniform metastable ? UMo phase is expected to transform to a mixture of ?-U and ?'-U_2Mo phase. The presence of transformation products in final U-10Mo fuel, especially the ? phase is considered detrimental for fuel irradiation performance, so it is critical to accurately evaluate the extent of transformation in the final U-10Mo alloy. This phase transformation can cause a volume change that induces a density change in final alloy. To understand this density and volume change, we developed a theoretical model to calculate the volume expansion and resultant density change of U-10Mo alloy as a function of the extent of eutectoid transformation. Based on the theoretically calculated density change for 0 to 100% transformation, we conclude that an experimental density measurement system will be challenging to employ to reliably detect and quantify the extent of transformation. Subsequently, to assess the ability of various methods to detect the transformation in U-10Mo, we annealed U-10Mo alloy samples at 500°C for various times to achieve in low, medium, and high extent of transformation. After the heat treatment at 500°C, the samples were metallographically polished and subjected to optical microscopy and x-ray diffraction (XRD) methods. Based on our assessment, optical microscopy and image processing can be used to determine the transformed area fraction, which can then be correlated with the ? phase volume fraction measured by XRD analysis. XRD analysis of U-10Mo aged at 500°C detected only ? phase and no ?' was detected. To further validate the XRD results, atom probe tomography (APT) was used to understand the composition of transformed regions in U-10Mo alloys aged at 500°C for 10 hours. Based on the APT results, the lamellar transformation product was found to comprise ? phase with close to 0 at% Mo and ? phase with 28-32 at% Mo, and the Mo concentration was highest at the ?/? interface.

  20. Integrating remotely sensed surface water extent into continental scale hydrology.

    Science.gov (United States)

    Revilla-Romero, Beatriz; Wanders, Niko; Burek, Peter; Salamon, Peter; de Roo, Ad

    2016-12-01

    In hydrological forecasting, data assimilation techniques are employed to improve estimates of initial conditions to update incorrect model states with observational data. However, the limited availability of continuous and up-to-date ground streamflow data is one of the main constraints for large-scale flood forecasting models. This is the first study that assess the impact of assimilating daily remotely sensed surface water extent at a 0.1° × 0.1° spatial resolution derived from the Global Flood Detection System (GFDS) into a global rainfall-runoff including large ungauged areas at the continental spatial scale in Africa and South America. Surface water extent is observed using a range of passive microwave remote sensors. The methodology uses the brightness temperature as water bodies have a lower emissivity. In a time series, the satellite signal is expected to vary with changes in water surface, and anomalies can be correlated with flood events. The Ensemble Kalman Filter (EnKF) is a Monte-Carlo implementation of data assimilation and used here by applying random sampling perturbations to the precipitation inputs to account for uncertainty obtaining ensemble streamflow simulations from the LISFLOOD model. Results of the updated streamflow simulation are compared to baseline simulations, without assimilation of the satellite-derived surface water extent. Validation is done in over 100 in situ river gauges using daily streamflow observations in the African and South American continent over a one year period. Some of the more commonly used metrics in hydrology were calculated: KGE', NSE, PBIAS%, R 2 , RMSE, and VE. Results show that, for example, NSE score improved on 61 out of 101 stations obtaining significant improvements in both the timing and volume of the flow peaks. Whereas the validation at gauges located in lowland jungle obtained poorest performance mainly due to the closed forest influence on the satellite signal retrieval. The conclusion is that

  1. Prevalence, Vascular Distribution, and Multiterritorial Extent of Subclinical Atherosclerosis in a Middle-Aged Cohort

    DEFF Research Database (Denmark)

    Fernández-Friera, Leticia; Peñalvo, José L; Fernández-Ortiz, Antonio

    2015-01-01

    age, 45.8 years; 63% male) to evaluate the systemic extent of atherosclerosis in the carotid, abdominal aortic, and iliofemoral territories by 2-/3-dimensional ultrasound and coronary artery calcification by computed tomography. The extent of subclinical atherosclerosis, defined as presence of plaque...

  2. Chromosphere of K giant stars. Geometrical extent and spatial structure detection

    Science.gov (United States)

    Berio, P.; Merle, T.; Thévenin, F.; Bonneau, D.; Mourard, D.; Chesneau, O.; Delaa, O.; Ligi, R.; Nardetto, N.; Perraut, K.; Pichon, B.; Stee, P.; Tallon-Bosc, I.; Clausse, J. M.; Spang, A.; McAlister, H.; ten Brummelaar, T.; Sturmann, J.; Sturmann, L.; Turner, N.; Farrington, C.; Goldfinger, P. J.

    2011-11-01

    Context. Interferometers provide accurate diameter measurements of stars by analyzing both the continuum and the lines formed in photospheres and chromospheres. Tests of the geometrical extent of the chromospheres are therefore possible by comparing the estimated radius in the continuum of the photosphere and the estimated radii in chromospheric lines. Aims: We aim to constrain the geometrical extent of the chromosphere of non-binary K giant stars and detect any spatial structures in the chromosphere. Methods: We performed observations with the CHARA interferometer and the VEGA beam combiner at optical wavelengths. We observed seven non-binary K giant stars (β and η Cet, δ Crt, ρ Boo, β Oph, 109 Her, and ι Cep). We measured the ratio of the radii of the photosphere to the chromosphere using the interferometric measurements in the Hα and the Ca II infrared triplet line cores. For β Cet, spectro-interferometric observations are compared to a non-local thermal equilibrium (NLTE) semi-empirical model atmosphere including a chromosphere. The NLTE computations provide line intensities and contribution functions that indicate the relative locations where the line cores are formed and can constrain the size of the limb-darkened disk of the stars with chromospheres. We measured the angular diameter of seven K giant stars and deduced their fundamental parameters: effective temperatures, radii, luminosities, and masses. We determined the geometrical extent of the chromosphere for four giant stars (β and η Cet, δ Crt and ρ Boo). Results: The chromosphere extents obtained range between 16% to 47% of the stellar radius. The NLTE computations confirm that the Ca II/849 nm line core is deeper in the chromosphere of β Cet than either of the Ca II/854 nm and Ca II/866 nm line cores. We present a modified version of a semi-empirical model atmosphere derived by fitting the Ca II triplet line cores of this star. In four of our targets, we also detect the signature of a

  3. Generation of plastic influence functions for J-integral and crack opening displacement of thin-walled pipes with a short circumferential through-wall crack

    International Nuclear Information System (INIS)

    Park, Jeong Soon; Choi, Young Hwan; Im, Seyoung

    2014-01-01

    Fracture mechanics parameters such as the J-integral and crack opening displacement (COD), are necessary for Leak-Before-Break (LBB) evaluation. The famous two estimation methods, the GE/EPRI and the Reference Stress Method (RSM), have their applicability limit with regard to the ratio of a pipe mean radius to thickness (R m /t). In order to extend their applicability limit to a thin walled pipe, several finite element analyses are performed for the J-integral and COD, and then new plastic influence functions are developed for thin-walled pipes with a short circumferential through-wall crack. With the newly generated plastic influence functions, the GE/EPRI and the RSM give closer results with those obtained from detailed finite element analyses. In addition, C*-integral and COD rate are estimated by using the new plastic influence functions and they are well matched with elastic–creep finite element analysis results under the power-law creep condition. Since the LBB concept can be applied to a piping system in a Korean Sodium-cooled Fast Reactor (SFR) which is designed to have thin-walled pipes and to operate in high temperature enough to cause creep, this paper can be applied for the LBB assessment of thin-walled pipes with a short through-wall crack in the SFR

  4. Left ventricular strain and its pattern estimated from cine CMR and validation with DENSE.

    Science.gov (United States)

    Gao, Hao; Allan, Andrew; McComb, Christie; Luo, Xiaoyu; Berry, Colin

    2014-07-07

    Measurement of local strain provides insight into the biomechanical significance of viable myocardium. We attempted to estimate myocardial strain from cine cardiovascular magnetic resonance (CMR) images by using a b-spline deformable image registration method. Three healthy volunteers and 41 patients with either recent or chronic myocardial infarction (MI) were studied at 1.5 Tesla with both cine and DENSE CMR. Regional circumferential and radial left ventricular strains were estimated from cine and DENSE acquisitions. In all healthy volunteers, there was no difference for peak circumferential strain (- 0.18 ± 0.04 versus - 0.18 ± 0.03, p = 0.76) between cine and DENSE CMR, however peak radial strain was overestimated from cine (0.84 ± 0.37 versus 0.49 ± 0.2, p cine were similar to the patterns from DENSE, including the strain evolution related to recovery time and strain patterns related to MI scar extent. Furthermore, cine-derived strain disclosed different strain patterns in MI and non-MI regions, and regions with transmural and non-transmural MI as DENSE. Although there were large variations with radial strain measurements from cine CMR images, useful circumferential strain information can be obtained from routine clinical CMR imaging. Cine strain analysis has potential to improve the diagnostic yield from routine CMR imaging in clinical practice.

  5. Determining the ice seasons severity during 1982-2015 using the ice extents sum as a new characteristic

    Science.gov (United States)

    Rjazin, Jevgeni; Pärn, Ove

    2016-04-01

    Sea ice is a key climate factor and it restricts considerably the winter navigation in sever seasons on the Baltic Sea. So determining ice conditions severity and describing ice cover behaviour at severe seasons interests scientists, engineers and navigation managers. The present study is carried out to determine the ice seasons severity degree basing on the ice seasons 1982 to 2015. A new integrative characteristic is introduced to describe the ice season severity. It is the sum of ice extents of the ice season id est the daily ice extents of the season are summed. The commonly used procedure to determine the ice season severity degree by the maximal ice extent is in this research compared to the new characteristic values. The remote sensing data on the ice concentrations on the Baltic Sea published in the European Copernicus Programme are used to obtain the severity characteristic values. The ice extents are calculated on these ice concentration data. Both the maximal ice extent of the season and a newly introduced characteristic - the ice extents sum are used to classify the winters with respect of severity. The most severe winter of the reviewed period is 1986/87. Also the ice seasons 1981/82, 1984/85, 1985/86, 1995/96 and 2002/03 are classified as severe. Only three seasons of this list are severe by both the criteria. They are 1984/85, 1985/86 and 1986/87. We interpret this coincidence as the evidence of enough-during extensive ice cover in these three seasons. In several winters, for example 2010/11 ice cover extended enough for some time, but did not endure. At few other ice seasons as 2002/03 the Baltic Sea was ice-covered in moderate extent, but the ice cover stayed long time. At 11 winters the ice extents sum differed considerably (> 10%) from the maximal ice extent. These winters yield one third of the studied ice seasons. The maximal ice extent of the season is simple to use and enables to reconstruct the ice cover history and to predict maximal ice

  6. Extent and distribution of skeletal muscle necrosis after graded periods of complete ischemia

    International Nuclear Information System (INIS)

    Labbe, R.; Lindsay, T.; Walker, P.M.

    1987-01-01

    The management of an acutely ischemic extremity requires knowledge of the response of skeletal muscle (the largest component of the lower limb) to prolonged periods of complete normothermic ischemia. We have used the canine gracilis muscle model to evaluate the extent and distribution of ischemic necrosis after 3 and 5 hours of ischemia and 48 hours of reperfusion. Each muscle was cut into six slices, and the extent and distribution of postischemic necrosis identified by means of nitroblue tetrazolium staining and 99mTc pyrophosphate uptake. After 3, 4, and 5 hours of ischemia the extent of necrosis was 2.0% +/- 0.9%, 30.3% +/- 6.0%, and 90.1% +/- 3.5% (mean +/- SEM), respectively. A statistically significant correlation exists between the extent of necrosis and the uptake of 99mTc pyrophosphate uptake per gram of tissue (y = 1574.9x - 8.4, r = 0.84, p less than 0.001). Most necrosis was centrally located and found in the thickest portion of the muscle. We conclude that there is a graded response in the extent of skeletal muscle necrosis related to the length of ischemic stress rather than an ''all-or-none'' phenomenon. This central distribution of necrosis makes the usual external evaluation of ischemic damage clinically unreliable. In addition, since there was no enveloping fascia in this model, a compartment release alone may not prevent the development of skeletal muscle necrosis. This knowledge of the response of skeletal muscle to ischemia may lead to an improved clinical approach to an extremity suffering a prolonged ischemic insult

  7. Evaluation of circumferential angle closure using iridotrabecular contact index after laser iridotomy by swept-source optical coherence tomography.

    Science.gov (United States)

    Cho, Hyun-Kyung; Ahn, Dongsub; Kee, Changwon

    2017-05-01

    To investigate the quantitative changes of circumferential angle closure after laser iridotomy (LI) using the iridotrabecular contact (ITC) index by Swept-Source optical coherence tomography (OCT). In this prospective observational study conducted in a hospital setting, 42 eyes of 36 patients (five males, 31 females) who underwent LI were included. The mean age was 65.00 ± 8.13 years old and the diagnosis included primary angle closure (PAC, 21 eyes), PAC suspect (16 eyes) and PAC glaucoma (five eyes). Optical coherence tomography (OCT) images were obtained pre-LI and at 1 week post-LI. In each image frame, the scleral spur (SS) and the ITC end-point were marked, from which the ITC index was calculated as a percentage of the angle closure across 360°. Measurements inspected before and after LI included: central anterior chamber depth (ACD), anterior chamber volume (ACV), lens vault (LV), nasal and temporal angle opening distance (AOD), angle recess area (ARA), trabecular-iris space area (TISA), trabecular-iris angle (TIA) at 500 μm and 750 μm from the SS and intraocular pressure (IOP). The ITC index and IOP decreased significantly after LI from 71.52 ± 26.29 to 35.31 ± 27.19 and from 20.64 ± 12.72 mmHg to 14.02 ± 3.49 mmHg, respectively (p  0.05), but ACV increased significantly after LI (p angle parameters except for nasal TIAs increased significantly after LI (all p angle showed a significant decrease after LI, but part of the angle closure was not relieved after LI. Other mechanisms besides pupillary block may play a role together in causing angle closure. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. A new application of Bull's eye analysis to lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yasui, Kotaro; Kohno, Yoshihiro; Akaki, Shiro; Hasegawa, Mari; Nakagawa, Tomio; Simizu, Mitsuharu; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao.

    1990-01-01

    Technetium-99m macroaggregated albumin lung perfusion scintigraphy was performed and evaluated semiquantitatively by Bull's eye analysis in 24, including 7 with central pulmonary carcinoma, 3 with hypersensitivity pneumonitis (HP), 3 with diffuse panbronchiolitis (DPB) and 11 normal subjects. First, whole lung field was divided into three regions by three concentric circles. And then radial axes were projected from the center to define 36 sectors, 10 degree each. The counts of each sector was calculated and Bull's eye image and circumferential profile curve were displayed. The patient's map was compared with the lower limit of normal (mean-2 SD), and the extent score (ES) and the severity score (SS) were calculated. The ES was 0.25±0.12 in pulmonary carcinoma (n=7), 0.08±0.07 in HP (n=3), 0.06±0.04 in DPB (n=3). The SS was 26.39±15.17 in pulmonary carcinoma, 4.75±5.57 in HP, 4.29±3.67 in DPB. In one case of central pulmonary carcinoma, segmental perfusion defect was evaluated semiquantitatively by Bull's eye image and circumferential profile curve. And in one case of HP, the change of regional pulmonary blood flow could be followed easily using extent and severity map. This new application of Bull's eye analysis to lung perfusion scintigraphy might be useful to evaluate regional pulmonary blood flow. (author)

  9. Learning Curve in a Western Training Center of the Circumferential En Bloc Esophageal Endoscopic Submucosal Dissection in an In Vivo Animal Model

    Directory of Open Access Journals (Sweden)

    Miguel A. Tanimoto

    2011-01-01

    Full Text Available Aim. Evaluate the feasibility to overcome the learning curve in a western training center of the en bloc circumferential esophageal (ECE- ESD in an in vivo animal model. Methods. ECE-ESD was performed on ten canine models under general anesthesia on artificial lesions at the esophagus marked with coagulation points. After the ESD each canine model was euthanized and surgical resection of the esophagus and stomach was carried out according to “the Principles of Humane Experimental Technique, Russel and Burch.” The specimen was fixed with needles on cork submerged in formalin with the esophagus and stomach then delivered to the pathology department to be analyzed. Results. ECE-ESD was completed without complications in the last 3/10 animal models. Mean duration for the procedures was 192±35 minutes (range 140–235 minutes. All the procedures were done at the animal lab surgery room with cardio pulmonary monitoring and artificial ventilation by staff surgery members and a staff member of the Gastroenterology department trained during 1999–2001 at the Fujigaoka hospital of the Showa U. in Yokohama, Japan, length (range 15–18 mm and 51±6.99 width (range 40–60 mm. Conclusion. ECE-ESD training is feasible in canine models for postgraduate endoscopy fellows.

  10. Exploring the extent to which ELT students utilise smartphones for ...

    African Journals Online (AJOL)

    Zehra

    2015-11-09

    Nov 9, 2015 ... aimed to explore the extent to which English Language Teaching (ELT) students utilise ... Given the fact that almost all students have a personal smartphone, and use it ..... ears as a disadvantage for smartphones (Kétyi,.

  11. Flood extent and water level estimation from SAR using data-model integration

    Science.gov (United States)

    Ajadi, O. A.; Meyer, F. J.

    2017-12-01

    Synthetic Aperture Radar (SAR) images have long been recognized as a valuable data source for flood mapping. Compared to other sources, SAR's weather and illumination independence and large area coverage at high spatial resolution supports reliable, frequent, and detailed observations of developing flood events. Accordingly, SAR has the potential to greatly aid in the near real-time monitoring of natural hazards, such as flood detection, if combined with automated image processing. This research works towards increasing the reliability and temporal sampling of SAR-derived flood hazard information by integrating information from multiple SAR sensors and SAR modalities (images and Interferometric SAR (InSAR) coherence) and by combining SAR-derived change detection information with hydrologic and hydraulic flood forecast models. First, the combination of multi-temporal SAR intensity images and coherence information for generating flood extent maps is introduced. The application of least-squares estimation integrates flood information from multiple SAR sensors, thus increasing the temporal sampling. SAR-based flood extent information will be combined with a Digital Elevation Model (DEM) to reduce false alarms and to estimate water depth and flood volume. The SAR-based flood extent map is assimilated into the Hydrologic Engineering Center River Analysis System (Hec-RAS) model to aid in hydraulic model calibration. The developed technology is improving the accuracy of flood information by exploiting information from data and models. It also provides enhanced flood information to decision-makers supporting the response to flood extent and improving emergency relief efforts.

  12. Circumferential margin involvement after total mesorectal excision for mid or low rectal cancer: are all R1 resections equal?

    Science.gov (United States)

    Beaufrère, A; Guedj, N; Maggiori, L; Patroni, A; Bedossa, P; Panis, Y

    2017-11-01

    Our aim was to assess the prognostic influence of the circumferential resection margin (CRM) exact value after total mesorectal excision for mid or low rectal cancer. All patients (n = 321) who underwent total mesorectal excision from 2005 to 2013 were identified from a prospective database, including 49 (15%) who presented with a CRM ≤ 1 mm. Four groups were defined: group 1, CRM = 0 mm (n = 21); group 2, 0 CRM ≤ 0.4 mm (n = 13); group 3, 0.4 CRM ≤ 1 mm (n = 15); group 4, CRM > 1 mm (n = 272). After a mean follow-up of 42 ± 26 months, locoregional recurrence rates were 8/21 (38%) in group 1, 3/13 (23%) in group 2, 0/12 (0%) in group 3 and 26/272 (10%) in group 4 (P CRM ≤ 0.4 mm was identified as an independent factor impairing both locoregional recurrence-free survival (OR 3.14, 95% CI 1.53-6.46; P = 0.002) and disease-free survival (OR 2.15, 95% CI 1.28-3.63; P = 0.004). Our study suggests that the prognosis after mid or low rectal cancer surgery was worse with a CRM ≤ 0.4 mm. The prognosis was similar in patients with a CRM > 0.4 mm or ≤ 1 mm and patients with an R0 resection. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  13. To what extent does banks' credit stimulate economic growth ...

    African Journals Online (AJOL)

    This study examines the extent to which banks' credit affects economic growth in Nigeria. The data used was collected from the Central Bank of Nigeria statistical bulletin for a period of 24 years from 1990 to 2013. We used credit to the private sector, credit to the public sector and inflation to proxy commercial bank credit ...

  14. Absence of Rapid Propagation through the Purkinje Network as a Potential Cause of Line Block in the Human Heart with Left Bundle Branch Block.

    Science.gov (United States)

    Okada, Jun-Ichi; Washio, Takumi; Nakagawa, Machiko; Watanabe, Masahiro; Kadooka, Yoshimasa; Kariya, Taro; Yamashita, Hiroshi; Yamada, Yoko; Momomura, Shin-Ichi; Nagai, Ryozo; Hisada, Toshiaki; Sugiura, Seiryo

    2018-01-01

    Background: Cardiac resynchronization therapy is an effective device therapy for heart failure patients with conduction block. However, a problem with this invasive technique is the nearly 30% of non-responders. A number of studies have reported a functional line of block of cardiac excitation propagation in responders. However, this can only be detected using non-contact endocardial mapping. Further, although the line of block is considered a sign of responders to therapy, the mechanism remains unclear. Methods: Herein, we created two patient-specific heart models with conduction block and simulated the propagation of excitation based on a cellmodel of electrophysiology. In one model with a relatively narrow QRS width (176 ms), we modeled the Purkinje network using a thin endocardial layer with rapid conduction. To reproduce a wider QRS complex (200 ms) in the second model, we eliminated the Purkinje network, and we simulated the endocardial mapping by solving the inverse problem according to the actual mapping system. Results: We successfully observed the line of block using non-contact mapping in the model without the rapid propagation of excitation through the Purkinje network, although the excitation in the wall propagated smoothly. This model of slow conduction also reproduced the characteristic properties of the line of block, including dense isochronal lines and fractionated local electrocardiograms. Further, simulation of ventricular pacing from the lateral wall shifted the location of the line of block. By contrast, in the model with the Purkinje network, propagation of excitation in the endocardial map faithfully followed the actual propagation in the wall, without showing the line of block. Finally, switching the mode of propagation between the two models completely reversed these findings. Conclusions: Our simulation data suggest that the absence of rapid propagation of excitation through the Purkinje network is the major cause of the functional line

  15. Detecting the Extent of Eutectoid Transformation in U-10Mo

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, Arun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jana, Saumyadeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McInnis, Colleen A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lombardo, Nicholas J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Joshi, Vineet V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sweet, Lucas E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Manandhar, Sandeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-08-31

    During eutectoid transformation of U-10Mo alloy, uniform metastable γ UMo phase is expected to transform to a mixture of α-U and γ’-U2Mo phase. The presence of transformation products in final U-10Mo fuel, especially the α phase is considered detrimental for fuel irradiation performance, so it is critical to accurately evaluate the extent of transformation in the final U-10Mo alloy. This phase transformation can cause a volume change that induces a density change in final alloy. To understand this density and volume change, we developed a theoretical model to calculate the volume expansion and resultant density change of U-10Mo alloy as a function of the extent of eutectoid transformation. Based on the theoretically calculated density change for 0 to 100% transformation, we conclude that an experimental density measurement system will be challenging to employ to reliably detect and quantify the extent of transformation. Subsequently, to assess the ability of various methods to detect the transformation in U-10Mo, we annealed U-10Mo alloy samples at 500°C for various times to achieve in low, medium, and high extent of transformation. After the heat treatment at 500°C, the samples were metallographically polished and subjected to optical microscopy and x-ray diffraction (XRD) methods. Based on our assessment, optical microscopy and image processing can be used to determine the transformed area fraction, which can then be correlated with the α phase volume fraction measured by XRD analysis. XRD analysis of U-10Mo aged at 500°C detected only α phase and no γ’ was detected. To further validate the XRD results, atom probe tomography (APT) was used to understand the composition of transformed regions in U-10Mo alloys aged at 500°C for 10 hours. Based on the APT results, the lamellar transformation product was found to comprise α phase with close to 0 at% Mo and γ phase with 28–32 at% Mo, and the Mo concentration was highest at the

  16. The regional extent of suppression: strabismics versus nonstrabismics.

    Science.gov (United States)

    Babu, Raiju Jacob; Clavagnier, Simon R; Bobier, William; Thompson, Benjamin; Hess, Robert F

    2013-10-09

    Evidence is accumulating that suppression may be the cause of amblyopia rather than a secondary consequence of mismatched retinal images. For example, treatment interventions that target suppression may lead to better binocular and monocular outcomes. Furthermore, it has recently been demonstrated that the measurement of suppression may have prognostic value for patching therapy. For these reasons, the measurement of suppression in the clinic needs to be improved beyond the methods that are currently available, which provide a binary outcome. We describe a novel quantitative method for measuring the regional extent of suppression that is suitable for clinical use. The method involves a dichoptic perceptual matching procedure at multiple visual field locations. We compare a group of normal controls (mean age: 28 ± 5 years); a group with strabismic amblyopia (four with microesotropia, five with esotropia, and one with exotropia; mean age: 35 ± 10 years); and a group with nonstrabismic anisometropic amblyopia (mean age: 33 ± 12 years). The extent and magnitude of suppression was similar for observers with strabismic and nonstrabismic amblyopia. Suppression was strongest within the central field and extended throughout the 20° field that we measured. Suppression extends throughout the central visual field in both strabismic and anisometropic forms of amblyopia. The strongest suppression occurs within the region of the visual field corresponding to the fovea of the fixing eye.

  17. Extent and impact of industry sponsorship conflicts of interest in dermatology research.

    Science.gov (United States)

    Perlis, Clifford S; Harwood, Michael; Perlis, Roy H

    2005-06-01

    Many published clinical trials are authored by investigators with financial conflicts of interest. The general medical literature documents the pervasive extent and sometimes problematic impact of these conflicts. Accordingly, there is renewed discussion about author disclosure and clinical trial registry to minimize publication bias from financial conflicts of interest. Despite this evolving discussion in the general medical literature, little is known about the extent or role of financial conflicts of interest in dermatology research. Our purpose was to determine the extent and impact of industry sponsorship conflicts of interest in dermatology research. We recorded potential financial conflicts of interest, study design, and study outcome in 179 clinical trials published between Oct 1, 2000 and Oct 1, 2003 in four leading dermatology journals. Forty-three percent of analyzed studies included at least one author with a reported conflict of interest. These studies were more likely to report a positive result, demonstrate higher methodological quality, and include a larger sample size. Conflict of interest in clinical investigations in dermatology appears to be prevalent and associated with potentially significant differences in study methodology and reporting.

  18. The Combined Incremental Prognostic Value of LVEF, Late Gadolinium Enhancement, and Global Circumferential Strain Assessed by CMR.

    Science.gov (United States)

    Mordi, Ify; Bezerra, Hiram; Carrick, David; Tzemos, Nikolaos

    2015-05-01

    This study aimed to assess the incremental prognostic value of global circumferential strain (GCS), as measured using cardiac magnetic resonance (CMR) tagging, in addition to baseline clinical characteristics, left ventricular ejection fraction (LVEF), and late gadolinium enhancement (LGE), in the prediction of major adverse cardiovascular events (MACE) in an unselected cohort of patients. LVEF is a powerful predictor of mortality and is used for guiding treatment decisions. It is, however, subject to limitations. The value of GCS measured by CMR tagging in patients with suspected cardiac disease has not been fully explored despite its being considered as the gold standard noninvasive method of assessment of LV deformation. We prospectively evaluated data from 539 consecutive patients referred for CMR who underwent a CMR protocol that included cine imaging, tagging, and LGE. The primary endpoint was the prevalence of MACE, defined as a composite of all-cause mortality, heart failure-related hospitalization, and aborted sudden cardiac death. MACE occurred in 62 of 539 patients (11.5%) over a mean follow-up period of 2.2 years. History of ischemic heart disease (IHD) and beta-blocker use were both significant clinical predictors of adverse outcomes. All 3 CMR parameters were significant multivariate predictors of the primary outcome when added to significant clinical predictors (LVEF, hazard ratio [HR]: 0.96 [95% confidence interval [CI]: 0.94 to 0.99; p = 0.005]; presence of LGE, HR: 2.07 [95% CI: 1.03 to 4.14; p = 0.04]; GCS, HR: 1.11 [95% CI: 1.02 to 1.21; p = 0.041]). Global chi-square increased significantly with the addition of both LGE and GCS. Both the presence of LGE and reduced GCS had independent prognostic value in the overall cohort. Patients with LVEF ≥35% but LGE present and reduced GCS had a poor outcome similar to that in those with LVEF value. This measure could provide further risk stratification, especially in patients with mild LV impairment

  19. Quantifying emphysema extent from weakly labeled CT scans of the lungs using label proportions learning

    DEFF Research Database (Denmark)

    Ørting, Silas Nyboe; Petersen, Jens; Wille, Mathilde

    2016-01-01

    Quantification of emphysema extent is important in diagnosing and monitoring patients with chronic obstructive pulmonary disease (COPD). Several studies have shown that emphysema quantification by supervised texture classification is more robust and accurate than traditional densitometry. Current...... techniques require highly time consuming manual annotations of patches or use only weak labels indicating overall disease status (e.g, COPD or healthy). We show how visual scoring of regional emphysema extent can be exploited in a learning with label proportions (LLP) framework to both predict presence...... of emphysema in smaller patches and estimate regional extent. We evaluate performance on 195 visually scored CT scans and achieve an intraclass correlation of 0.72 (0.65–0.78) between predicted region extent and expert raters. To our knowledge this is the first time that LLP methods have been applied...

  20. Evolutionary history, immigration history, and the extent of diversification in community assembly.

    Science.gov (United States)

    Knope, Matthew L; Forde, Samantha E; Fukami, Tadashi

    2011-01-01

    During community assembly, species may accumulate not only by immigration, but also by in situ diversification. Diversification has intrigued biologists because its extent varies even among closely related lineages under similar ecological conditions. Recent research has suggested that some of this puzzling variation may be caused by stochastic differences in the history of immigration (relative timing and order of immigration by founding populations), indicating that immigration and diversification may affect community assembly interactively. However, the conditions under which immigration history affects diversification remain unclear. Here we propose the hypothesis that whether or not immigration history influences the extent of diversification depends on the founding populations' prior evolutionary history, using evidence from a bacterial experiment. To create genotypes with different evolutionary histories, replicate populations of Pseudomonas fluorescens were allowed to adapt to a novel environment for a short or long period of time (approximately 10 or 100 bacterial generations) with or without exploiters (viral parasites). Each evolved genotype was then introduced to a new habitat either before or after a standard competitor genotype. Most genotypes diversified to a greater extent when introduced before, rather than after, the competitor. However, introduction order did not affect the extent of diversification when the evolved genotype had previously adapted to the environment for a long period of time without exploiters. Diversification of these populations was low regardless of introduction order. These results suggest that the importance of immigration history in diversification can be predicted by the immigrants' evolutionary past. The hypothesis proposed here may be generally applicable in both micro- and macro-organisms.

  1. Arterial Stiffness and its Correlation with the Extent of Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Hourak Poorzand

    2018-06-01

    Full Text Available Introduction: Coronary artery disease secondary to atherosclerosis is the most common cause of mortality. Coronary angiography is the most precise method for determining the extent of disease in the coronary vascular bed. Arterial stiffness has been proposed as a marker of atherosclerosis in some studies. One of the noninvasive methods for the determination of arterial stiffness is Doppler echocardiography. In this study, we aimed to find the correlation between arterial stiffness as measured by echocardiography and the extent of coronary artery disease as evaluated through angiography. Materials and Methods: Aortic pulse wave velocity (APWV was measured by using the Doppler method in 70 patients, who were candidates for coronary angiography. The extent of coronary artery disease was determined quantitatively in terms of Friesinger index and semi-quantitatively as the number of vessels with stenosis of over 50%. Then, the correlation between arterial stiffness and these factors was evaluated. Results: The mean APWV was 9.1±5 m/s. There was a direct relationship between APWV and Friesinger index, which was not statistically significant (P=0.67. The mean APWV for patients with one-vessel disease was 4.4±1.8 m/s, while it was 9.9±3.6 m/s in patients with two and 7.9±4 m/s in three-vessel disease which did not show statistically significant difference. Conclusion: Doppler echocardiography to measure APWV was not considered as a promising tool to predict the extent of coronary artery disease.

  2. Predictors of circumferential resection margin involvement in surgically resected rectal cancer: A retrospective review of 23,464 patients in the US National Cancer Database.

    Science.gov (United States)

    Al-Sukhni, Eisar; Attwood, Kristopher; Gabriel, Emmanuel; Nurkin, Steven J

    2016-04-01

    The circumferential resection margin (CRM) is a key prognostic factor after rectal cancer resection. We sought to identify factors associated with CRM involvement (CRM+). A retrospective review was performed of the National Cancer Database, 2004-2011. Patients with rectal cancer who underwent radical resection and had a recorded CRM were included. Multivariable analysis of the association between clinicopathologic characteristics and CRM was performed. Tumor CRM+. Of 23,464 eligible patients, 13.3% were CRM+. Factors associated with CRM+ were diagnosis later in the study period, lack of insurance, advanced stage, higher grade, undergoing APR, and receiving radiation. Nearly half of CRM+ patients did not receive neoadjuvant therapy. CRM+ patients who did not receive neoadjuvant therapy were more likely to be female, older, with more comorbidities, smaller tumors, earlier clinical stage, advanced pathologic stage, and CEA-negative disease compared to those who received it. Factors associated with CRM+ include features of advanced disease, undergoing APR, and lack of health insurance. Half of CRM+ patients did not receive neoadjuvant treatment. These represent cases where CRM status may be modifiable with appropriate pre-operative selection and multidisciplinary management. Copyright © 2016 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  3. Veterinary drug prescriptions: to what extent do pet owners comply ...

    African Journals Online (AJOL)

    Separate questionnaires were designed for pet owners (clients) and veterinarians to ascertain the existence and extent of noncompliance in veterinary practice in lbadan and to elucidate the influence of such factors as logistics, education, economy, attitudes and veterinarian/client relationship on non-compliance. Analyses ...

  4. 241-AY-101 Tank Construction Extent of Condition Review for Tank Integrity

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Travis J.; Gunter, Jason R.

    2013-08-26

    This report provides the results of an extent of condition construction history review for tank 241-AY-101. The construction history of tank 241-AY-101 has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In tank 241-AY-101, the second double-shell tank constructed, similar issues as those with tank 241-AY-102 construction reoccurred. The overall extent of similary and affect on tank 241-AY-101 integrity is described herein.

  5. Reassessing the extent of the Q classification for containment paint

    International Nuclear Information System (INIS)

    Spires, G.

    1995-01-01

    A mounting number of site-specific paint debris transport and screen clogging analyses submitted to justify substandard containment paint work have been deemed persuasive by virtue of favorable U.S. Nuclear Regulatory Commission safety evaluation report (SER) findings. These lay a strong foundation for a standardized approach to redefining the extent to which paint in containment needs to be considered open-quotes Q.close quotes This information justifies an initiative by licensees to roll back paint work quality commitments made at the design phase. This paper questions the validity of the basic premise that all primary containment paint can significantly compromise core and containment cooling [emergency core cooling system/engineered safeguard feature (ECCS/ESF)]. It is posited that the physical extent of painted containment surfaces for which extant material qualification and quality control (QC) structures need apply can be limited to zones relatively proximate to ECCS/ESF suction points. For other painted containment surfaces, simplified criteria should be allowed

  6. LEVEL AND EXTENT OF MERCURY CONTAMINATION IN OREGON LOTIC FISH

    Science.gov (United States)

    As part of the U.S. EPA's EMAP Oregon Pilot project, we conducted a probability survey of 154 Oregon streams and rivers to assess the spatial extent of mercury (Hg) contamination in fish tissue across the state. Samples consisted of whole fish analyses of both small (< 120 mm) a...

  7. Global Human Built-up And Settlement Extent (HBASE) Dataset From Landsat

    Data.gov (United States)

    National Aeronautics and Space Administration — The Global Human Built-up And Settlement Extent (HBASE) Dataset from Landsat is a global map of HBASE derived from the Global Land Survey (GLS) Landsat dataset for...

  8. Corticocortical feedback increases the spatial extent of normalization.

    Science.gov (United States)

    Nassi, Jonathan J; Gómez-Laberge, Camille; Kreiman, Gabriel; Born, Richard T

    2014-01-01

    Normalization has been proposed as a canonical computation operating across different brain regions, sensory modalities, and species. It provides a good phenomenological description of non-linear response properties in primary visual cortex (V1), including the contrast response function and surround suppression. Despite its widespread application throughout the visual system, the underlying neural mechanisms remain largely unknown. We recently observed that corticocortical feedback contributes to surround suppression in V1, raising the possibility that feedback acts through normalization. To test this idea, we characterized area summation and contrast response properties in V1 with and without feedback from V2 and V3 in alert macaques and applied a standard normalization model to the data. Area summation properties were well explained by a form of divisive normalization, which computes the ratio between a neuron's driving input and the spatially integrated activity of a "normalization pool." Feedback inactivation reduced surround suppression by shrinking the spatial extent of the normalization pool. This effect was independent of the gain modulation thought to mediate the influence of contrast on area summation, which remained intact during feedback inactivation. Contrast sensitivity within the receptive field center was also unaffected by feedback inactivation, providing further evidence that feedback participates in normalization independent of the circuit mechanisms involved in modulating contrast gain and saturation. These results suggest that corticocortical feedback contributes to surround suppression by increasing the visuotopic extent of normalization and, via this mechanism, feedback can play a critical role in contextual information processing.

  9. 241-AW Tank Farm Construction Extent of Condition Review for Tank Integrity

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Travis J.; Gunter, Jason R.; Reeploeg, Gretchen E.

    2013-11-19

    This report provides the results of an extent of condition construction history review for the 241-AW tank farm. The construction history of the 241-AW tank farm has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In the 241-AW tank farm, the fourth double-shell tank farm constructed, similar issues as those with tank 241-AY-102 construction occured. The overall extent of similary and affect on 241-AW tank farm integrity is described herein.

  10. Inability to determine tissue health is main indication of allograft use in intermediate extent burns.

    Science.gov (United States)

    Fletcher, John L; Cancio, Leopoldo C; Sinha, Indranil; Leung, Kai P; Renz, Evan M; Chan, Rodney K

    2015-12-01

    Cutaneous allograft is commonly used in the early coverage of excised burns when autograft is unavailable. However, allograft is also applied in intermediate-extent burns (25-50%), during cases in which it is possible to autograft. In this population, there is a paucity of data on the indications for allograft use. This study explores the indications for allograft usage in moderate size burns. Under an IRB-approved protocol, patients admitted to our burn unit between March 2003 and December 2010 were identified through a review of the burn registry. Data on allograft use, total burn surface area, operation performed, operative intent, number of operations, intensive care unit length of stay, and overall length of stay were collected and analyzed. Data are presented as means±standard deviations, except where noted. In the study period, 146 patients received allograft during their acute hospitalization. Twenty-five percent of allograft recipients sustained intermediate-extent burns. Patients with intermediate-extent burns received allograft later in their hospitalization than those with large-extent (50-75% TBSA) burns (6.8 days vs. 3.4 days, p=0.01). Allografted patients with intermediate-extent burns underwent more operations (10.8 vs. 6.1, p=0.002) and had longer hospitalizations (78.3 days vs. 40.9 days, ppatients, when controlled for TBSA. Clinical rationale for placement of allograft in this population included autograft failure, uncertain depth of excision, lack of autograft donor site, and wound complexity. When uncertain depth of excision was the indication, allograft was universally applied onto the face. In half of allografted intermediate-extent burn patients the inability to identify a viable recipient bed was the ultimate reason for allograft use. Unlike large body surface area burns, allograft skin use in intermediate-extent injury occurs later in the hospitalization and is driven by the inability to determine wound bed suitability for autograft

  11. Endoscopic Mucosal Resection with Circumferential Mucosal Incision for Colorectal Neoplasms: Comparison with Endoscopic Submucosal Dissection and between Two Endoscopists with Different Experiences

    Directory of Open Access Journals (Sweden)

    Dong-Hoon Yang

    2017-07-01

    Full Text Available Background/Aims Endoscopic mucosal resection with circumferential mucosal incision (CMI-EMR may offer benefits comparable to those of endoscopic submucosal dissection (ESD, while requiring less technical proficiency than ESD. Methods We retrospectively compared the outcomes of CMI-EMR (n=34 and size-matched ESD (n=102, which were performed by a Korean endoscopist for colorectal epithelial lesions of 20–35 mm. Procedural parameters of CMI-EMRs performed by an American ESD novice (n=30 were compared with those performed by the Korean endoscopist. Results The lesion size was 22.3±3.9 mm and 22.9±2.4 mm in the CMI-EMR and size-matched ESD groups, respectively (p=0.730. The resection time was 12.7±7.0 minutes in the CMI-EMR group and 45.6±30.1 minutes in the ESD group (p<0.001. The en bloc resection rate was 94.1% in the CMI-EMR group and 100% in the ESD group (p=0.061. There were no differences in the en bloc resection and complication rates of CMI-EMRs between a Korean and an American endoscopist. Conclusions For the treatment of moderate-size colorectal lesions, CMI-EMR showed a trend toward lower en bloc resection rate, but required shorter procedure time than ESD. CMI-EMR outcomes were similar when performed by a Korean ESD expert and an American ESD novice.

  12. Is circumferential urethral mobilisation an overdo? A prospective outcome analysis of dorsal onlay and dorso - lateral onlay BMGU for anterior urethral strictures.

    Science.gov (United States)

    Prakash, Gaurav; Singh, Bhupendra Pal; Sinha, Rahul Janak; Jhanwar, Ankur; Sankhwar, Satyanarayan

    2018-01-01

    For dorsal onlay graft placement, unilateral urethral mobilization is less invasive than standard circumferential urethral mobilization. Apart from success in terms of patency of urethra, other issues like sexual function, overall quality of life and patient satisfaction remain important issues while comparing outcomes of urethroplasty. To prospectively compare the objective as well as subjective outcomes of two approaches. Between July 2011 and January 2015, 136 adult males having anterior urethral stricture with urethral lumen ≥ 6 Fr. were prospectively assigned between two groups by alternate randomization. Operative time, complications, success rate (no obstructive symptoms, no need of any postoperative intervention, Q max > 15mL/sec), sexual functions (using Brief Male Sexual Function Inventory) were compared. Baseline parameters were similar in both groups (68 in each group). Overall success rate was similar in both groups (89 % and 91 % respectively). Improvement in total LUTS scores was similar in groups. Changes in overall health status (VAS and EQ 5D) was equal in both groups. Erectile function score was significantly decreased in DO than DL group while ejaculatory function and sexual desire remained stable after urethroplasty in both groups. In anterior urethral stricture buccal mucosa graft provides satisfactory results as onlay technique. No technique whether dorsolateral and dorsal techniques is superior to other. Dorsolateral technique needs minimal urethral mobilization and should be preferred whenever feasible. Copyright® by the International Brazilian Journal of Urology.

  13. Gonioscopy assisted transluminal trabeculotomy: an ab interno circumferential trabeculotomy for the treatment of primary congenital glaucoma and juvenile open angle glaucoma.

    Science.gov (United States)

    Grover, Davinder S; Smith, Oluwatosin; Fellman, Ronald L; Godfrey, David G; Butler, Michelle R; Montes de Oca, Ildamaris; Feuer, William J

    2015-08-01

    To introduce a novel ab interno 360° trabeculotomy for treating primary congenital glaucoma (PCG) and juvenile open angle glaucoma (JOAG) and report preliminary results. A retrospective chart review of patients who underwent a gonioscopy assisted transluminal trabeculotomy (GATT) procedure by four of the authors (DSG, OS, RLF and DGG) between October 2011 and October 2013. The surgery was performed in patients ≤30 years old with a dysgenic anterior segment angle and uncontrolled PCG and JOAG. Fourteen eyes of 10 patients underwent GATT with follow-up >12 months (12-33 months; mean 20.4). Patients ranged in age from 17 months to 30 years (mean=18.4 years), and five (50%) were female patients. No complications occurred during or following surgery except for early postoperative hyphema in five (36%) of eyes, all cleared by 1 month. The mean intraocular pressure (IOP) decreased from 27.3 to 14.8 mm Hg and the mean number of medications required decreased from 2.6 to 0.86. Five eyes had a drop in IOP ≥15 mm Hg (range 15-39). The preliminary results and safety for GATT, a minimally invasive conjunctival sparing circumferential trabeculotomy, are promising and at least equivalent to previous results for ab externo trabeculotomy for the treatment of PCG and JOAG. All eyes in the study were considered a clinical success. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Comment on ''Canonical formalism for Lagrangians with nonlocality of finite extent''

    International Nuclear Information System (INIS)

    Llosa, Josep

    2003-01-01

    The paper by Woodward [Phys. Rev. A 62, 052105 (2000)] claimed to have proved that Lagrangian theories with a nonlocality of finite extent are necessarily unstable. In this Comment we propose that this conclusion is false

  15. Cook Inlet and Kenai Peninsula, Alaska ESI: ICE (Ice Extent Lines)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains locations of ice extent in Cook Inlet, Alaska. Vector lines in the data set represent 50 percent ice coverage. Location-specific type and...

  16. The value and extent of religious participation of members of the ...

    African Journals Online (AJOL)

    2013-01-14

    Jan 14, 2013 ... ... of Human. Resource Management, .... This is why employees of the SAPS, as human beings, to a large extent ... everywhere, supporting us in the workplace, at home and in hospitals. ..... such as diversity interventions).

  17. The extent of problematic alcohol and other drug use within selected ...

    African Journals Online (AJOL)

    Objective. To describe the nature and extent of AOD problems in selected workplace ... compiled by an Employee Assistance Programme (EAP) service provider in SA. As part of an EAP risk audit, assessments for AOD-related problems were ...

  18. Left ventricular strain and its pattern estimated from cine CMR and validation with DENSE

    International Nuclear Information System (INIS)

    Gao, Hao; Luo, Xiaoyu; Allan, Andrew; McComb, Christie; Berry, Colin

    2014-01-01

    Measurement of local strain provides insight into the biomechanical significance of viable myocardium. We attempted to estimate myocardial strain from cine cardiovascular magnetic resonance (CMR) images by using a b-spline deformable image registration method. Three healthy volunteers and 41 patients with either recent or chronic myocardial infarction (MI) were studied at 1.5 Tesla with both cine and DENSE CMR. Regional circumferential and radial left ventricular strains were estimated from cine and DENSE acquisitions. In all healthy volunteers, there was no difference for peak circumferential strain (− 0.18 ± 0.04 versus − 0.18 ± 0.03, p = 0.76) between cine and DENSE CMR, however peak radial strain was overestimated from cine (0.84 ± 0.37 versus 0.49 ± 0.2, p < 0.01). In the patient study, the peak strain patterns predicted by cine were similar to the patterns from DENSE, including the strain evolution related to recovery time and strain patterns related to MI scar extent. Furthermore, cine-derived strain disclosed different strain patterns in MI and non-MI regions, and regions with transmural and non-transmural MI as DENSE. Although there were large variations with radial strain measurements from cine CMR images, useful circumferential strain information can be obtained from routine clinical CMR imaging. Cine strain analysis has potential to improve the diagnostic yield from routine CMR imaging in clinical practice. (paper)

  19. A Global Geospatial Database of 5000+ Historic Flood Event Extents

    Science.gov (United States)

    Tellman, B.; Sullivan, J.; Doyle, C.; Kettner, A.; Brakenridge, G. R.; Erickson, T.; Slayback, D. A.

    2017-12-01

    A key dataset that is missing for global flood model validation and understanding historic spatial flood vulnerability is a global historical geo-database of flood event extents. Decades of earth observing satellites and cloud computing now make it possible to not only detect floods in near real time, but to run these water detection algorithms back in time to capture the spatial extent of large numbers of specific events. This talk will show results from the largest global historical flood database developed to date. We use the Dartmouth Flood Observatory flood catalogue to map over 5000 floods (from 1985-2017) using MODIS, Landsat, and Sentinel-1 Satellites. All events are available for public download via the Earth Engine Catalogue and via a website that allows the user to query floods by area or date, assess population exposure trends over time, and download flood extents in geospatial format.In this talk, we will highlight major trends in global flood exposure per continent, land use type, and eco-region. We will also make suggestions how to use this dataset in conjunction with other global sets to i) validate global flood models, ii) assess the potential role of climatic change in flood exposure iii) understand how urbanization and other land change processes may influence spatial flood exposure iv) assess how innovative flood interventions (e.g. wetland restoration) influence flood patterns v) control for event magnitude to assess the role of social vulnerability and damage assessment vi) aid in rapid probabilistic risk assessment to enable microinsurance markets. Authors on this paper are already using the database for the later three applications and will show examples of wetland intervention analysis in Argentina, social vulnerability analysis in the USA, and micro insurance in India.

  20. The extent of groundwater use for domestic and irrigation activities ...

    African Journals Online (AJOL)

    AKMENSAH

    2015-06-04

    Jun 4, 2015 ... Albert Kobina Mensah1*, Evans Appiah Kissi2, Kwabena Krah3 and Okoree D. Mireku4. 1Department of Geography, Kenyatta University, Nairobi. 2Department of .... catchment in Kiambu County in Kenya had limited themselves to the assessment of water quality. Little work has been done on the extent to ...

  1. The extent and impact of outsourcing: evidence from Germany

    OpenAIRE

    Craig P. Aubuchon; Subhayu Bandyopadhyay; Sumon Bhaumik

    2012-01-01

    The authors use data from several sources, including plant-level data from the manufacturing sector in Germany, to expand the literature on outsourcing. They find that, in Germany, the extent of outsourcing among manufacturing industries is higher than among service industries and that the outsourcing intensity of these industries did not change much between 1995 and 2005. They also find a statistically significantly positive impact of industry-level outsourcing intensity on German plant-leve...

  2. Corticocortical feedback increases the spatial extent of normalization

    Science.gov (United States)

    Nassi, Jonathan J.; Gómez-Laberge, Camille; Kreiman, Gabriel; Born, Richard T.

    2014-01-01

    Normalization has been proposed as a canonical computation operating across different brain regions, sensory modalities, and species. It provides a good phenomenological description of non-linear response properties in primary visual cortex (V1), including the contrast response function and surround suppression. Despite its widespread application throughout the visual system, the underlying neural mechanisms remain largely unknown. We recently observed that corticocortical feedback contributes to surround suppression in V1, raising the possibility that feedback acts through normalization. To test this idea, we characterized area summation and contrast response properties in V1 with and without feedback from V2 and V3 in alert macaques and applied a standard normalization model to the data. Area summation properties were well explained by a form of divisive normalization, which computes the ratio between a neuron's driving input and the spatially integrated activity of a “normalization pool.” Feedback inactivation reduced surround suppression by shrinking the spatial extent of the normalization pool. This effect was independent of the gain modulation thought to mediate the influence of contrast on area summation, which remained intact during feedback inactivation. Contrast sensitivity within the receptive field center was also unaffected by feedback inactivation, providing further evidence that feedback participates in normalization independent of the circuit mechanisms involved in modulating contrast gain and saturation. These results suggest that corticocortical feedback contributes to surround suppression by increasing the visuotopic extent of normalization and, via this mechanism, feedback can play a critical role in contextual information processing. PMID:24910596

  3. The value of the 12-lead electrocardiogram in localizing the scar in non-ischaemic cardiomyopathy.

    Science.gov (United States)

    Oloriz, Teresa; Wellens, Hein J J; Santagostino, Giulia; Trevisi, Nicola; Silberbauer, John; Peretto, Giovanni; Maccabelli, Giuseppe; Della Bella, Paolo

    2016-12-01

    Patients with non-ischaemic cardiomyopathy (NICM) and ventricular tachycardia can be categorized as anteroseptal (AS) or inferolateral (IL) scar sub-types based on imaging and voltage mapping studies. The aim of this study was to correlate the baseline electrocardiogram (ECG) with endo-epicardial voltage maps created during ablation procedures and identify the ECG characteristics that may help to distinguish the scar as AS or IL. We assessed 108 baseline ECGs; 72 patients fulfilled criteria for dilated cardiomyopathy whereas 36 showed minimal structural abnormalities. Based on the unipolar low-voltage distribution, the scar pattern was classified as predominantly AS (n = 59) or IL (n = 49). Three ECG criteria (PR interval 230 ms or QRS > 170 ms or an r ≤ 0.3 mV in V3 having 92 and 81% of sensitivity and specificity, respectively, in predicting AS scar pattern. A significant negative correlation was found between the extension of the endocardial unipolar low voltage area and left ventricular EF (r s = -0.719, P < 0.001). The extent of endocardial AS unipolar low voltage was correlated with PR interval and QRS duration (r s = 0.583 and r s = 0.680, P < 0.001, respectively) and the IL epicardial unipolar low voltage with the mean voltage of the limb leads (r s = -0.639, P < 0.001). Baseline ECG features are well correlated with the distribution of unipolar voltage abnormalities in NICM and may help to predict the location of scar in this population. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. Estimating the seaward extent of sea breeze from QuickSCAT scatterometry

    Digital Repository Service at National Institute of Oceanography (India)

    Aparna, M.; Shetye, S.R.; Shankar, D.; Shenoi, S.S.C.; Mehra, P.; Desai, R.G.P.

    An objective method for quantifying the seaward extent of the sea breeze is presented. The underlying assumption is that the offshore decay in the strength of the sea breeze results in an offshore decay of the vector correlation between the wind...

  5. A method for predicting the extent of petroleum hydrocarbon biodegradation in contaminated soils

    International Nuclear Information System (INIS)

    Huesemann, M.H.

    1994-01-01

    A series of solid- and slurry-phase soil bioremediation experiments involving different crude oils and refined petroleum products were performed to investigate the factors which affect the maximum extent of total petroleum hydrocarbon (TPH) biodegradation. The authors used a comprehensive petroleum hydrocarbon characterization procedure involving group-type separation analyses, boiling-point distributions, and hydrocarbon typing by field ionization mass spectroscopy. Initial and final concentrations of specified hydrocarbon classes were determined in each of seven different bioremediation treatments. Generally, they found that the degree of TPH biodegradation was affected mainly by the type of hydrocarbons in the contaminant matrix. In contrast, the influence of experimental variables such as soil type, fertilizer concentrations, microbial plate counts, and treatment type (slurry versus landfarming) on the overall extent of TPH biodegradation was insignificant. Based on these findings, a predictive algorithm was developed to estimate the extent of TPH biodegradation from the average reduction of 86 individual hydrocarbon classes and their respective initial concentrations. Model predictions for gravimetric TPH removals were in close agreement with analytical results from two independent laboratories

  6. The Extent of Immature Fish Harvesting by the Commercial Fishery ...

    African Journals Online (AJOL)

    The sustainability of a given fishery is a function of the number of sexually matured fish present in water. If there is intensive immature fishing, the population of fish reaching the stage of recruitment will decrease, which in turn results in lower yield and biomass. The present study was conducted to estimate the extent of ...

  7. Qualification of UT methods and systems used for in-service inspections of VVER 440 vessels

    International Nuclear Information System (INIS)

    Skala, Z.; Vit, J.

    2003-01-01

    SKODA JS has been performing automated in-service inspections VVER reactor pressure vessels for more than twenty years. All of these inspections were performed by ultrasonic pulse echo method, combined from 1996 with eddy current testing. The Time of Flight Diffraction Method (TOFD) is one of modern methods of ultrasonic testing. The accuracy of sizing the through wall extent of a flaw by TOFD is much better than the accuracy achievable by the pulse echo method. A series of laboratory tests were performed by SKODA JS and confirmed the suitability of TOFD method for VVER reactor parts testing. The Czech Atomic law demands the qualification of systems and methods used for the in-service inspections of nuclear reactors. The qualification is done in accordance with ENIQ methodology and consists of preparation of the Technical Justification and practical tests made under the surveillance of Qualification Body. SKODA JS intends to qualify systems and methods used for the automated ultrasonic testing of VVER 440 and VVER 1000 reactor components from the inner as well as from the outer surface. The accuracy of the flaw through wall extent sizing by TOFD was confirmed by the qualification of methods and systems used for the testing of VVER 440 vessel circumferential weld and so the TOFD method shall be used routinely by SKODA JS for the inspection of vessel circumferential welds root area and for sizing of flaws exceeding the acceptance level. (author)

  8. Extent and application of patient diaries in Austria

    DEFF Research Database (Denmark)

    Heindl, Patrik; Bachlechner, Adelbert; Nydahl, Peter

    2017-01-01

    Background: Diaries written for patients in the intensive care unit (ICU) are offered in many European countries. In Austria, ICU diaries have been relatively unknown, but since 2012, they have started to emerge. Aim: The aim of this study was to explore the extent and application of ICU diaries...... in Austria in 2015. Method: The study had a prospective multiple methods design of survey and interviews. All ICUs in Austria were surveyed in 2015 to identify which ICUs used diaries. ICUs using diaries were selected for semi-structured key-informant telephone interviews on the application of ICU diaries...

  9. Rapid Estimates of Rupture Extent for Large Earthquakes Using Aftershocks

    Science.gov (United States)

    Polet, J.; Thio, H. K.; Kremer, M.

    2009-12-01

    The spatial distribution of aftershocks is closely linked to the rupture extent of the mainshock that preceded them and a rapid analysis of aftershock patterns therefore has potential for use in near real-time estimates of earthquake impact. The correlation between aftershocks and slip distribution has frequently been used to estimate the fault dimensions of large historic earthquakes for which no, or insufficient, waveform data is available. With the advent of earthquake inversions that use seismic waveforms and geodetic data to constrain the slip distribution, the study of aftershocks has recently been largely focused on enhancing our understanding of the underlying mechanisms in a broader earthquake mechanics/dynamics framework. However, in a near real-time earthquake monitoring environment, in which aftershocks of large earthquakes are routinely detected and located, these data may also be effective in determining a fast estimate of the mainshock rupture area, which would aid in the rapid assessment of the impact of the earthquake. We have analyzed a considerable number of large recent earthquakes and their aftershock sequences and have developed an effective algorithm that determines the rupture extent of a mainshock from its aftershock distribution, in a fully automatic manner. The algorithm automatically removes outliers by spatial binning, and subsequently determines the best fitting “strike” of the rupture and its length by projecting the aftershock epicenters onto a set of lines that cross the mainshock epicenter with incremental azimuths. For strike-slip or large dip-slip events, for which the surface projection of the rupture is recti-linear, the calculated strike correlates well with the strike of the fault and the corresponding length, determined from the distribution of aftershocks projected onto the line, agrees well with the rupture length. In the case of a smaller dip-slip rupture with an aspect ratio closer to 1, the procedure gives a measure

  10. The Extent of Educational Technology's Influence on Contemporary Educational Practices

    OpenAIRE

    Kim, Bradford-Watts

    2005-01-01

    This paper investigates how advances in educational technologies have influenced contemporary educational practices.It discusses the nature of educational technology, the limitations imposed by the digital divide and other factors of uptake, and the factors leading to successful implementation of educational technologies.The extent of influence is then discussed,together with the probable implications for educational sites for the future.

  11. Real-time 3D visualization of cellular rearrangements during cardiac valve formation.

    Science.gov (United States)

    Pestel, Jenny; Ramadass, Radhan; Gauvrit, Sebastien; Helker, Christian; Herzog, Wiebke; Stainier, Didier Y R

    2016-06-15

    During cardiac valve development, the single-layered endocardial sheet at the atrioventricular canal (AVC) is remodeled into multilayered immature valve leaflets. Most of our knowledge about this process comes from examining fixed samples that do not allow a real-time appreciation of the intricacies of valve formation. Here, we exploit non-invasive in vivo imaging techniques to identify the dynamic cell behaviors that lead to the formation of the immature valve leaflets. We find that in zebrafish, the valve leaflets consist of two sets of endocardial cells at the luminal and abluminal side, which we refer to as luminal cells (LCs) and abluminal cells (ALCs), respectively. By analyzing cellular rearrangements during valve formation, we observed that the LCs and ALCs originate from the atrium and ventricle, respectively. Furthermore, we utilized Wnt/β-catenin and Notch signaling reporter lines to distinguish between the LCs and ALCs, and also found that cardiac contractility and/or blood flow is necessary for the endocardial expression of these signaling reporters. Thus, our 3D analyses of cardiac valve formation in zebrafish provide fundamental insights into the cellular rearrangements underlying this process. © 2016. Published by The Company of Biologists Ltd.

  12. Obesity and extent of emphysema depicted at CT

    International Nuclear Information System (INIS)

    Gu, S.; Li, R.; Leader, J.K.; Zheng, B.; Bon, J.; Gur, D.; Sciurba, F.; Jin, C.; Pu, J.

    2015-01-01

    Aim: To investigate the underlying relationship between obesity and the extent of emphysema depicted at CT. Methods and materials: A dataset of 477 CT examinations was retrospectively collected from a study of chronic obstructive pulmonary disease (COPD). The low attenuation areas (LAAs; ≤950 HU) of the lungs were identified. The extent of emphysema (denoted as %LAA) was defined as the percentage of LAA divided by the lung volume. The association between log-transformed %LAA and body mass index (BMI) adjusted for age, sex, the forced expiratory volume in one second as percent predicted value (FEV1% predicted), and smoking history (pack years) was assessed using multiple linear regression analysis. Results: After adjusting for age, gender, smoking history, and FEV1% predicted, BMI was negatively associated with severe emphysema in patients with COPD. Specifically, one unit increase in BMI is associated with a 0.93-fold change (95% CI: 0.91–0.96, p < 0.001) in %LAA; the estimated %LAA for males was 1.75 (95% CI: 1.36–2.26, p < 0.001) times that of females; per 10% increase in FEV1% predicated is associated with a 0.72-fold change (95% CI: 0.69–0.76, p < 0.001) in %LAA. Conclusion: Increasing obesity is negatively associated with severity of emphysema independent of gender, age, and smoking history. - Highlights: • BMI is inversely associated with emphysema depicted on CT. • Emphysema severity in men was higher than that in women. • ∼50% of the subjects with COPD in our dataset were either overweight or obese. • Age and smoking status are not significantly associated with %LAA

  13. Automated flood extent identification using WorldView imagery for the insurance industry

    Science.gov (United States)

    Geller, Christina

    2017-10-01

    Flooding is the most common and costly natural disaster around the world, causing the loss of human life and billions in economic and insured losses each year. In 2016, pluvial and fluvial floods caused an estimated 5.69 billion USD in losses worldwide with the most severe events occurring in Germany, France, China, and the United States. While catastrophe modeling has begun to help bridge the knowledge gap about the risk of fluvial flooding, understanding the extent of a flood - pluvial and fluvial - in near real-time allows insurance companies around the world to quantify the loss of property that their clients face during a flooding event and proactively respond. To develop this real-time, global analysis of flooded areas and the associated losses, a new methodology utilizing optical multi-spectral imagery from DigitalGlobe (DGI) WorldView satellite suite is proposed for the extraction of pluvial and fluvial flood extents. This methodology involves identifying flooded areas visible to the sensor, filling in the gaps left by the built environment (i.e. buildings, trees) with a nearest neighbor calculation, and comparing the footprint against an Industry Exposure Database (IE) to calculate a loss estimate. Full-automation of the methodology allows production of flood extents and associated losses anywhere around the world as required. The methodology has been tested and proven effective for the 2016 flood in Louisiana, USA.

  14. a research tool for analysing and monitoring the Extent to which ...

    African Journals Online (AJOL)

    practice at the majority of under-resourced rural schools in the country. ... into the extent to which they integrate natural resource management issues. ... education is promoted as the best educational strategy to deal with the ... environmental sustainability and human wellbeing. ..... Comparative Education, 38(2), 171–187.

  15. The Role of Deposition in Limiting the Hazard Extent of Dense-Gas Plumes

    Energy Technology Data Exchange (ETDEWEB)

    Dillon, M B

    2008-01-29

    Accidents involving release of large (multi-ton) quantities of toxic industrial chemicals often yield far fewer fatalities and causalities than standard, widely-used assessment and emergency response models predict. While recent work has suggested that models should incorporate the protection provided by buildings, more refined health effect methodologies, and more detailed consideration of the release process; investigations into the role of deposition onto outdoor surfaces has been lacking. In this paper, we examine the conditions under which dry deposition may significantly reduce the extent of the downwind hazard zone. We provide theoretical arguments that in congested environments (e.g. suburbs, forests), deposition to vertical surfaces (such as building walls) may play a significant role in reducing the hazard zone extent--particularly under low-wind, stable atmospheric conditions which are often considered to be the worst-case scenario for these types of releases. Our analysis suggests that in these urban or suburban environments, the amount of toxic chemicals lost to earth's surface is typically a small fraction of overall depositional losses. For isothermal gases such as chlorine, the degree to which the chemicals stick to (or react with) surfaces (i.e. surface resistance) is demonstrated to be a key parameter controlling hazard extent (the maximum distance from the release at which hazards to human health are expected). This analysis does not consider the depositional effects associated with particulate matter or gases that undergo significant thermal change in the atmosphere. While no controlled experiments were available to validate our hypothesis, our analysis results are qualitatively consistent with the observed downwind extent of vegetation damage in two chlorine accidents.

  16. LBA-ECO LC-07 Wetland Extent, Vegetation, and Inundation: Lowland Amazon Basin

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set provides a map of wetland extent, vegetation type, and dual-season flooding state of the entire lowland Amazon basin. The map was derived from mosaics...

  17. Not Extent of Telecommuting, But Job Characteristics as Proximal Predictors of Work-Related Well-Being.

    Science.gov (United States)

    Vander Elst, Tinne; Verhoogen, Ronny; Sercu, Maarten; Van den Broeck, Anja; Baillien, Elfi; Godderis, Lode

    2017-10-01

    This study aimed to investigate the curvilinear relationship between extent of telecommuting and work-related well-being (ie, burnout, work engagement, and cognitive stress complaints), as well as to test whether job characteristics act as explanatory mechanisms underlying this relationship. A sample of 878 employees from an international telecommunication company with a long history of telecommuting participated in a survey on psychosocial risk factors and well-being at work. Mediation path analyses were conducted to test the hypotheses. Social support from colleagues, participation in decision-making, task autonomy, and work-to-family conflict, but not extent of telecommuting, were directly related to work-related well-being. Extent of telecommuting was indirectly related to well-being via social support. Employers should invest in creating good work environments in general, among both telecommuters and nontelecommuters.

  18. Extent of reference services to users in Ebonyi State Public Libraary ...

    African Journals Online (AJOL)

    Users are very satisfied with the extent of reference services provided to them by the public library studied. Findings further show that the reference section of Ebonyi State Public Library, Abakiliki is faced with the problems of inadequate reading space, equipment and furniture, reference information sources, unconducive ...

  19. Tracking fine-scale seasonal evolution of surface water extent in Central Alaska and the Canadian Shield

    Science.gov (United States)

    Cooley, S. W.; Smith, L. C.; Pitcher, L. H.; Pavelsky, T.; Topp, S.

    2017-12-01

    Quantifying spatial and temporal variability in surface water storage at high latitudes is critical for assessing environmental sensitivity to climate change. Traditionally the tradeoff between high spatial and high temporal resolution space-borne optical imagery has limited the ability to track fine-scale changes in surface water extent. However, the recent launch of hundreds of earth-imaging CubeSats by commercial satellite companies such as Planet opens up new possibilities for monitoring surface water from space. In this study we present a comparison of seasonal evolution of surface water extent in two study areas with differing geologic, hydrologic and permafrost regimes, namely, the Yukon Flats in Central Alaska and the Canadian Shield north of Yellowknife, N.W.T. Using near-daily 3m Planet CubeSat imagery, we track individual lake surface area from break-up to freeze-up during summer 2017 and quantify the spatial and temporal variability in inundation extent. We validate our water delineation method and inundation extent time series using WorldView imagery, coincident in situ lake shoreline mapping and pressure transducer data for 19 lakes in the Northwest Territories and Alaska collected during the NASA Arctic Boreal Vulnerability Experiment (ABoVE) 2017 field campaign. The results of this analysis demonstrate the value of CubeSat imagery for dynamic surface water research particularly at high latitudes and illuminate fine-scale drivers of cold regions surface water extent.

  20. Measurement of extent of intense ion beam charge neutralization

    Energy Technology Data Exchange (ETDEWEB)

    Engelko, V [Efremov Institute of Electrophysical Apparatus, St. Petersburg (Russian Federation); Giese, H; Schalk, S [Forschungszentrum Karlsruhe (Germany). INR

    1997-12-31

    Various diagnostic tools were employed to study and optimize the extent of space charge neutralization in the pulsed intense proton beam facility PROFA, comprising Langmuir probes, capacitive probes, and a novel type of the three electrode collector. The latter does not only allow us to measure ion and electron beam current densities in a high magnetic field environment, but also to deduce the density spectrum of the beam electrons. Appropriate operating conditions were identified to attain a complete space charge neutralisation. (author). 5 figs., 4 refs.

  1. Assessment of the depth and extent of myometrial invasion in uterine adenomyosis using MRI

    International Nuclear Information System (INIS)

    Yi, Mi Gyung; Cho, Jae Ho; Chang, Jay Chun; Park, Bok Hwan

    2000-01-01

    To determine the detection rate of MRI in the diagnosis of adenomyosis and ascertain the accuracy of MRI in assessing the extent and depth of the myometrial invasion. By retrospective analysis of MR images of the pelvis in 65 pathologically proven cases of uterine adenomyosis, we investigated the detection rate and differences of in the detection rate when this was based on (a) the extent, and (b) the depth of myometrial invasion. The condition was classified as diffuse or focal according to the extent of invasion, and mild, moderate, or severe according to its depth. Pathologically, there were 35 cases of focal adenomyosis (53.8%), and 30 of diffuse adenomyosis (46.2%). Among patients with the focal variety of this condition, 12 cases were mild, 14 were mild, 14 were moderate, and nine were severe, while among those with the diffuse variety, two were mild, ten were moderate and 18 were severe. A total of 48 cases (73.8%) were detected on MR images; the detection rate of focal adenomyosis was 60.0% (21/35) and that of diffuse adenomyosis was 90.0% (27/30). The detection rates of mild, moderate, and severe adenomyosis were 42.9% (6/14), 79.2% (19/24), and 85.2% (23/27), respectively. Among the 48 cases detected on MR images, the pathologic and MR findings were consistent with regard to both the extent and depth of myometrial invasion in 26 (54.2%). For diffuse adenomyosis, the consistency rate was higher than for the focal variety (81.5%, 22/27; compared with 19%, 4/21). The extent of myometrial invasion was correctly evaluated in 32 cases (66.7%); the consistency rate for the diffuse form was higher than for the focal form (96.3%(26/27), compared with 28.6% (6/21)). In 42 cases (87.5%), the depth of invasion was correctly evaluated, though differences in this depth were not significant. MR imaging was a useful imaging modality in the diagnosis of uterine adenomyosis. With regard to the extent of myometrial invasion, the detection rate was higher among cases of the

  2. Extent of Surgery Does Not Influence 30-Day Mortality in Surgery for Metastatic Bone Disease

    DEFF Research Database (Denmark)

    Sørensen, Michala Skovlund; Hindsø, Klaus; Hovgaard, Thea Bechmann

    2016-01-01

    describing the extent of the surgical trauma were found to be associated with 30-day mortality. The 30-day mortality in patients undergoing surgery for MBD is highly dependent on the general health status of the patients as measured by the ASA score and the Karnofsky performance status. The extent of surgery......, measured as duration of surgery, blood loss, and degree of bone resection were not associated with 30-day mortality....

  3. Human activities on the deep seafloor in the North East Atlantic: an assessment of spatial extent.

    Directory of Open Access Journals (Sweden)

    Angela R Benn

    Full Text Available BACKGROUND: Environmental impacts of human activities on the deep seafloor are of increasing concern. While activities within waters shallower than 200 m have been the focus of previous assessments of anthropogenic impacts, no study has quantified the extent of individual activities or determined the relative severity of each type of impact in the deep sea. METHODOLOGY: The OSPAR maritime area of the North East Atlantic was chosen for the study because it is considered to be one of the most heavily impacted by human activities. In addition, it was assumed data would be accessible and comprehensive. Using the available data we map and estimate the spatial extent of five major human activities in the North East Atlantic that impact the deep seafloor: submarine communication cables, marine scientific research, oil and gas industry, bottom trawling and the historical dumping of radioactive waste, munitions and chemical weapons. It was not possible to map military activities. The extent of each activity has been quantified for a single year, 2005. PRINCIPAL FINDINGS: Human activities on the deep seafloor of the OSPAR area of the North Atlantic are significant but their footprints vary. Some activities have an immediate impact after which seafloor communities could re-establish, while others can continue to make an impact for many years and the impact could extend far beyond the physical disturbance. The spatial extent of waste disposal, telecommunication cables, the hydrocarbon industry and marine research activities is relatively small. The extent of bottom trawling is very significant and, even on the lowest possible estimates, is an order of magnitude greater than the total extent of all the other activities. CONCLUSIONS/SIGNIFICANCE: To meet future ecosystem-based management and governance objectives for the deep sea significant improvements are required in data collection and availability as well as a greater awareness of the relative impact of

  4. Coil supporting device for thermonuclear device

    International Nuclear Information System (INIS)

    Okubo, Minoru; Ando, Toshiro; Ota, Mitsuru; Ishimura, Masabumi.

    1979-01-01

    Purpose: To lower the bending stress exerted on coils thereby preventing the coils from deformation by branching the outer circumferential support frames of coil support frames disposed at an equal pitch circumferentially to the coils into plurality, and integrally forming them to the inner circumferential support frames. Constitution: Each of the support frames for supporting poloidal coils winding around a vacuum vessel is bisected at the radial midway so that the outer circumferential branches are disposed at an equal pitch and they are formed integrally with the inner circumferential support frames. The inner circumferential support frames are fixed by support posts on a bed and the outer circumferential support frames are mounted to the outer edge of wedge-like support posts. Accordingly, if the coils expand outwardly upon increase in the temperature, the stress exerted on the support frame can be decreased. (Yoshino, Y.)

  5. Reconstructed North American, Eurasian, and Northern Hemisphere Snow Cover Extent, 1915-1997

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains time series of monthly snow cover extent (SCE) for North America, Eurasia, and the Northern Hemisphere from 1915 to 1997, based on snow cover...

  6. Sea Ice Edge Location and Extent in the Russian Arctic, 1933-2006

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Sea Ice Edge Location and Extent in the Russian Arctic, 1933-2006 data are derived from sea ice charts from the Arctic and Antarctic Research Institute (AARI),...

  7. Flood Extent Mapping for Namibia Using Change Detection and Thresholding with SAR

    Science.gov (United States)

    Long, Stephanie; Fatoyinbo, Temilola E.; Policelli, Frederick

    2014-01-01

    A new method for flood detection change detection and thresholding (CDAT) was used with synthetic aperture radar (SAR) imagery to delineate the extent of flooding for the Chobe floodplain in the Caprivi region of Namibia. This region experiences annual seasonal flooding and has seen a recent renewal of severe flooding after a long dry period in the 1990s. Flooding in this area has caused loss of life and livelihoods for the surrounding communities and has caught the attention of disaster relief agencies. There is a need for flood extent mapping techniques that can be used to process images quickly, providing near real-time flooding information to relief agencies. ENVISAT/ASAR and Radarsat-2 images were acquired for several flooding seasons from February 2008 to March 2013. The CDAT method was used to determine flooding from these images and includes the use of image subtraction, decision based classification with threshold values, and segmentation of SAR images. The total extent of flooding determined for 2009, 2011 and 2012 was about 542 km2, 720 km2, and 673 km2 respectively. Pixels determined to be flooded in vegetation were typically flooding in vegetation was much greater (almost one third of the total flooded area). The time to maximum flooding for the 2013 flood season was determined to be about 27 days. Landsat water classification was used to compare the results from the new CDAT with SAR method; the results show good spatial agreement with Landsat scenes.

  8. To what extent do science ESP learning materials fit the purpose for ...

    African Journals Online (AJOL)

    To what extent do science ESP learning materials fit the purpose for which they have been devised? An evaluation in terms of Cronje's (1993) criteria. ... Journal for Language Teaching. Journal Home · ABOUT THIS JOURNAL · Advanced ...

  9. Global extent and determinants of savanna and forest as alternative biome states

    CSIR Research Space (South Africa)

    Staver, C

    2011-10-01

    Full Text Available Theoretically, fire–tree cover feedbacks can maintain savanna and forest as alternative stable states. However, the global extent of fire- driven discontinuities in tree cover is unknown, especially accounting for seasonality and soils. The authors...

  10. The Extent to which the Chemistry Textbook of Grade 11 is ...

    African Journals Online (AJOL)

    The purpose of this study was to identify the extent to which the chemistry textbook of grade 11 in Ethiopian schools is appropriate for learner-centered approach. The content of the new chemistry textbook for grade 11 was analyzed vis-à-vis the suggested evidence of learnercentered techniques. The analysis covered the ...

  11. Determination of extent of surgical intervention for endometrial carcinoma

    International Nuclear Information System (INIS)

    Smakhtina, O.L.; Nugmanova, M.I.; Nigaj, S.V.

    1986-01-01

    Clinical, cytologic, histologic and X-ray procedures were used in examining 120 patients with endometrial carcinoma. The results of pre- and intraoperative determination of clinical stage were compared in 65 cases of uterine extirpation with appendages and lymphadenectomy. Errors in preoperative identification of the extent of tumor expansion were made in 9 cases (13.8+-4.3%). It was found that determinations of the site and expansion of tumor make the case for hysterocervico-angiolymphography whereas identification of tumor pattern and degree of cell differentiation-for cytologic and histologic assays

  12. Total Quality Management in Secondary Schools in Kenya: Extent of Practice

    Science.gov (United States)

    Ngware, Moses Waithanji; Wamukuru, David Kuria; Odebero, Stephen Onyango

    2006-01-01

    Purpose: To investigate the extent to which secondary schools practiced aspects of total quality management (TQM). Design/methodology/approach: A cross-sectional research design was used in this study. A sample of 300 teachers in a residential session during a school holiday provided their perceptions on the practice of TQM in their schools. Data…

  13. Quantifying Forest Spatial Pattern Trends at Multiple Extents: An Approach to Detect Significant Changes at Different Scales

    Directory of Open Access Journals (Sweden)

    Ludovico Frate

    2014-09-01

    Full Text Available We propose a procedure to detect significant changes in forest spatial patterns and relevant scales. Our approach consists of four sequential steps. First, based on a series of multi-temporal forest maps, a set of geographic windows of increasing extents are extracted. Second, for each extent and date, specific stochastic simulations that replicate real-world spatial pattern characteristics are run. Third, by computing pattern metrics on both simulated and real maps, their empirical distributions and confidence intervals are derived. Finally, multi-temporal scalograms are built for each metric. Based on cover maps (1954, 2011 with a resolution of 10 m we analyze forest pattern changes in a central Apennines (Italy reserve at multiple spatial extents (128, 256 and 512 pixels. We identify three types of multi-temporal scalograms, depending on pattern metric behaviors, describing different dynamics of natural reforestation process. The statistical distribution and variability of pattern metrics at multiple extents offers a new and powerful tool to detect forest variations over time. Similar procedures can (i help to identify significant changes in spatial patterns and provide the bases to relate them to landscape processes; (ii minimize the bias when comparing pattern metrics at a single extent and (iii be extended to other landscapes and scales.

  14. Effect of ischemia and postischemic dysfunction on myocardial uptake of technetium-99m-labeled methoxyisobutyl isonitrile and thallium-201

    International Nuclear Information System (INIS)

    Sinusas, A.J.; Watson, D.D.; Cannon, J.M. Jr.; Beller, G.A.

    1989-01-01

    The myocardial uptake of a new technetium-99m-labeled myocardial perfusion agent, methoxyisobutyl isonitrile (Tc-99m MIBI), and thallium-201 was correlated with microsphere flow in an open chest canine model of low coronary flow and postischemic dysfunction. Eighteen dogs were given an injection of thallium-201 (0.5 mCi) and Tc-99m MIBI (5 mCi) either after 40 min of partial left anterior descending artery occlusion (Group I, 10 dogs) or during reperfusion after 15 min of left anterior descending artery occlusion (Group II, 8 dogs). Regional dysfunction was documented during injection in both groups by quantitative two-dimensional echocardiography. Regional blood flow was assessed by radiolabeled microspheres. The heart was excised 15 min after radionuclide injection and the left ventricle divided into 96 segments for gamma well counting. Among Group I dogs, central ischemic thallium-201 and Tc-99m MIBI activity (expressed as a percent of the activity in the corresponding nonischemic zone) was comparable, respectively, for endocardial (54 +/- 17% and 52 +/- 17%), mid-wall (71 +/- 20% and 69 +/- 17%) and epicardial (89 +/- 13% and 94 +/- 9%) segments and increased proportionally with flow. There was a good linear correlation among these endocardial segments between flow and both thallium-201 (r = 0.78) and Tc-99m MIBI (r = 0.85) activity. Among Group II dogs, central ischemic endocardial flow (59 +/- 14%) was comparable to thallium-201 (70 +/- 18%) and Tc-99m MIBI (74 +/- 12%) activity. Similarly, relative endocardial flow in the intermediate ischemic region (71 +/- 11%) was comparable to thallium-201 (77 +/- 11%) and Tc-99m MIBI (81 +/- 10%) activity. Thus, myocardial uptake of Tc-99m MIBI and thallium-201 is comparable under conditions of low coronary flow and postischemic dysfunction and closely parallels flow alterations

  15. Association between the extent of sigmoid sinus dehiscence and an occurrence of pulsatile tinnitus: a retrospective imaging study

    International Nuclear Information System (INIS)

    Dong, C.; Zhao, P.; Liu, Z.; Xu, W.; Lv, H.; Pang, S.; Wang, Z.

    2016-01-01

    Aim: To assess the extent of sigmoid sinus dehiscence (SSD) on high-resolution computed tomography venography (HRCTV) or high-resolution computed tomography (HRCT) images in pulsatile tinnitus (PT) and non-PT groups to determine whether there is an association between the extent of SSD and occurrence of PT. Materials and methods: Twenty-eight SSD patients with ipsilateral PT and 28 age- and gender-matched SSD patients without PT who underwent HRCTV or HRCT were enrolled in this study and categorised into two groups: “PT group” and “non-PT group”. The extent of SSD in each group was calculated and compared. Results: The largest transverse diameter and largest vertical diameter of SSD in the PT group were 6.21±1.7 and 6.15±2.19 mm, respectively. The largest transverse diameter and largest vertical diameter of SSD in the non-PT group were 3.06±1.38 and 2.51±1.03 mm, respectively. The extent of SSD was statistically different between the two groups (p<0.001; p<0.001). Conclusions: As a cause of PT, SSD can also occur in individuals without PT symptoms. Preliminary findings suggest that there may be a potential correlation between the extent of SSD and an occurrence of PT. - Highlights: • We compared the extent of sigmoid sinus dehiscence in pulsatile tinnitus and non-pulsatile tinnitus groups. • The sigmoid sinus dehiscence in the pulsatile tinnitus patients was larger than those in non-pulsatile tinnitus patients. • There may be a potential correlation between the extent of sigmoid sinus dehiscence and an occurrence of pulsatile tinnitus.

  16. N-acetylcysteine for the prevention of stricture after circumferential endoscopic submucosal dissection of the esophagus: a randomized trial in a porcine model.

    Science.gov (United States)

    Barret, Maximilien; Batteux, Frédéric; Beuvon, Frédéric; Mangialavori, Luigi; Chryssostalis, Ariane; Pratico, Carlos; Chaussade, Stanislas; Prat, Frédéric

    2012-05-28

    Circumferential endoscopic submucosal dissection (CESD) of the esophagus would allow for both the eradication of Barrett's esophagus and its related complications, such as advanced neoplasia. However, such procedures generally induce inflammatory repair resulting in a fibrotic stricture. N-acetylcysteine (NAC) is an antioxidant that has shown some efficacy against pulmonary and hepatic fibrosis. The aim of our study was to evaluate the benefit of NAC in the prevention of esophageal cicatricial stricture after CESD in a swine model. Two groups of six pigs each were subjected to general anesthesia and CESD: after randomization, a first group received an oral NAC treatment regimen of 100 mg/kg/day, initiated one week before the procedure, whereas a second group was followed without any prophylactic treatment. Follow-up endoscopies took place seven, fourteen, twenty-one, and twenty-eight days after CESD. Necropsy, histological assessment of esophageal inflammation, and fibrosis were performed on day 28. The median esophageal lumen diameter on day 21 (main judgment criterion) was 4 mm (range 2 to 5) in group 1 and 3 mm (range 1 to 7) in group 2 (P = 0.95). No significant difference was observed between the two groups regarding clinical evaluation (time before onset of clinically significant esophageal obstruction), number of dilations, esophageal inflammation and fibrosis, or oxidative stress damage on immunohistochemistry. Despite its antioxidant effect, systemic administration of NAC did not show significant benefit on esophageal fibrosis in our animal model of esophageal wound healing within the experimental conditions of this study. Since the administered doses were relatively high, it seems unlikely that NAC might be a valuable option for the prevention of post-endoscopic esophageal stricture.

  17. Hilar cholangiocarcinoma: controversies on the extent of surgical resection aiming at cure.

    Science.gov (United States)

    Xiang, Shuai; Lau, Wan Yee; Chen, Xiao-ping

    2015-02-01

    Hilar cholangiocarcinoma is the most common malignant tumor affecting the extrahepatic bile duct. Surgical treatment offers the only possibility of cure, and it requires removal of all tumoral tissues with adequate resection margins. The aims of this review are to summarize the findings and to discuss the controversies on the extent of surgical resection aiming at cure for hilar cholangiocarcinoma. The English medical literatures on hilar cholangiocarcinoma were studied to review on the relevance of adequate resection margins, routine caudate lobe resection, extent of liver resection, and combined vascular resection on perioperative and long-term survival outcomes of patients with resectable hilar cholangiocarcinoma. Complete resection of tumor represents the most important prognostic factor of long-term survival for hilar cholangiocarcinoma. The primary aim of surgery is to achieve R0 resection. When R1 resection is shown intraoperatively, further resection is recommended. Combined hepatic resection is now generally accepted as a standard procedure even for Bismuth type I/II tumors. Routine caudate lobe resection is also advocated for cure. The extent of hepatic resection remains controversial. Most surgeons recommend major hepatic resection. However, minor hepatic resection has also been advocated in most patients. The decision to carry out right- or left-sided hepatectomy is made according to the predominant site of the lesion. Portal vein resection should be considered when its involvement by tumor is suspected. The curative treatment of hilar cholangiocarcinoma remains challenging. Advances in hepatobiliary techniques have improved the perioperative and long-term survival outcomes of this tumor.

  18. Statistics of Radial Ship Extent as Seen by a Seeker

    Science.gov (United States)

    2014-06-01

    Auckland in pure and applied mathematics and physics, and a Master of Science in physics from the same university with a thesis in applied accelerator...does not demand contributions from two angle bins to one extent bin, unlike the rectangle; this is a very big advantage of the ellipse model. However...waveform that mimics the full length of a ship. This allows more economical use to be made of available false-target generation resources. I wish to

  19. Cartilage link protein 1 (Crtl1), an extracellular matrix component playing an important role in heart development.

    Science.gov (United States)

    Wirrig, Elaine E; Snarr, Brian S; Chintalapudi, Mastan R; O'neal, Jessica L; Phelps, Aimee L; Barth, Jeremy L; Fresco, Victor M; Kern, Christine B; Mjaatvedt, Corey H; Toole, Bryan P; Hoffman, Stanley; Trusk, Thomas C; Argraves, W Scott; Wessels, Andy

    2007-10-15

    To expand our insight into cardiac development, a comparative DNA microarray analysis was performed using tissues from the atrioventricular junction (AVJ) and ventricular chambers of mouse hearts at embryonic day (ED) 10.5-11.0. This comparison revealed differential expression of approximately 200 genes, including cartilage link protein 1 (Crtl1). Crtl1 stabilizes the interaction between hyaluronan (HA) and versican, two extracellular matrix components essential for cardiac development. Immunohistochemical studies showed that, initially, Crtl1, versican, and HA are co-expressed in the endocardial lining of the heart, and in the endocardially derived mesenchyme of the AVJ and outflow tract (OFT). At later stages, this co-expression becomes restricted to discrete populations of endocardially derived mesenchyme. Histological analysis of the Crtl1-deficient mouse revealed a spectrum of cardiac malformations, including AV septal and myocardial defects, while expression studies showed a significant reduction in versican levels. Subsequent analysis of the hdf mouse, which carries an insertional mutation in the versican gene (CSPG2), demonstrated that haploinsufficient versican mice display septal defects resembling those seen in Crtl1(-/-) embryos, suggesting that reduced versican expression may contribute to a subset of the cardiac abnormalities observed in the Crtl1(-/-) mouse. Combined, these findings establish an important role for Crtl1 in heart development.

  20. In vivo imaging of the cyclic changes in cross-sectional shape of the ventricular segment of pulsating embryonic chick hearts at stages 14 to 17: a contribution to the understanding of the ontogenesis of cardiac pumping function.

    Science.gov (United States)

    Männer, Jörg; Thrane, Lars; Norozi, Kambiz; Yelbuz, T Mesud

    2009-12-01

    The cardiac cycle-related deformations of tubular embryonic hearts were traditionally described as concentric narrowing and widening of a tube of circular cross-section. Using optical coherence tomography (OCT), we have recently shown that, during the cardiac cycle, only the myocardial tube undergoes concentric narrowing and widening while the endocardial tube undergoes eccentric narrowing and widening, having an elliptic cross-section at end-diastole and a slit-shaped cross-section at end-systole. Due to technical limitations, these analyses were confined to early stages of ventricular development (chick embryos, stages 10-13). Using a modified OCT-system, we now document, for the first time, the cyclic changes in cross-sectional shape of beating embryonic ventricles at stages 14 to 17. We show that during these stages (1) a large area of diminished cardiac jelly appears at the outer curvature of the ventricular region associated with formation of endocardial pouches; (2) the ventricular endocardial lumen acquires a bell-shaped cross-section at end-diastole and becomes compressed like a fireplace bellows during systole; (3) the contracting portions of the embryonic ventricles display stretching along its baso-apical axis at end-systole. The functional significance of our data is discussed with respect to early cardiac pumping function. (c) 2009 Wiley-Liss, Inc.

  1. Does oxygen exposure time control the extent of organic matter decomposition in peatlands?

    Science.gov (United States)

    Philben, Michael; Kaiser, Karl; Benner, Ronald

    2014-05-01

    The extent of peat decomposition was investigated in four cores collected along a latitudinal gradient from 56°N to 66°N in the West Siberian Lowland. The acid:aldehyde ratios of lignin phenols were significantly higher in the two northern cores compared with the two southern cores, indicating peats at the northern sites were more highly decomposed. Yields of hydroxyproline, an amino acid found in plant structural glycoproteins, were also significantly higher in northern cores compared with southern cores. Hydroxyproline-rich glycoproteins are not synthesized by microbes and are generally less reactive than bulk plant carbon, so elevated yields indicated that northern cores were more extensively decomposed than the southern cores. The southern cores experienced warmer temperatures, but were less decomposed, indicating that temperature was not the primary control of peat decomposition. The plant community oscillated between Sphagnum and vascular plant dominance in the southern cores, but vegetation type did not appear to affect the extent of decomposition. Oxygen exposure time appeared to be the strongest control of the extent of peat decomposition. The northern cores had lower accumulation rates and drier conditions, so these peats were exposed to oxic conditions for a longer time before burial in the catotelm, where anoxic conditions prevail and rates of decomposition are generally lower by an order of magnitude.

  2. Dynamic and thermodynamic impacts of the winter Arctic Oscillation on summer sea ice extent.

    Science.gov (United States)

    Park, H. S.; Stewart, A.

    2017-12-01

    Arctic summer sea ice extent exhibits substantial interannual variability, as is highlighted by the remarkable recovery in sea ice extent in 2013 following the record minimum in the summer of 2012. Here, we explore the mechanism via which Arctic Oscillation (AO)-induced ice thickness changes impact summer sea ice, using observations and reanalysis data. A positive AO weakens the basin-scale anticyclonic sea ice drift and decreases the winter ice thickness by 15cm and 10cm in the Eurasian and the Pacific sectors of the Arctic respectively. Three reanalysis datasets show that the (upward) surface heat fluxes are reduced over wide areas of the Arctic, suppressing the ice growth during the positive AO winters. The winter dynamic and thermodynamic thinning preconditions the ice for enhanced radiative forcing via the ice-albedo feedback in late spring-summer, leading to an additional 8-10 cm of thinning over the Pacific sector of the Arctic. Because of these winter AO-induced dynamic and thermodynamics effects, the winter AO explains about 22% (r = -0.48) of the interannual variance of September sea ice extent from year 1980 to 2015.

  3. Northward extent of East Asian monsoon covaries with intensity on orbital and millennial timescales

    Science.gov (United States)

    Goldsmith, Yonaton; Broecker, Wallace S.; Xu, Hai; Polissar, Pratigya J.; deMenocal, Peter B.; Porat, Naomi; Lan, Jianghu; Cheng, Peng; Zhou, Weijian; An, Zhisheng

    2017-02-01

    The magnitude, rate, and extent of past and future East Asian monsoon (EAM) rainfall fluctuations remain unresolved. Here, late Pleistocene-Holocene EAM rainfall intensity is reconstructed using a well-dated northeastern China closed-basin lake area record located at the modern northwestern fringe of the EAM. The EAM intensity and northern extent alternated rapidly between wet and dry periods on time scales of centuries. Lake levels were 60 m higher than present during the early and middle Holocene, requiring a twofold increase in annual rainfall, which, based on modern rainfall distribution, requires a ˜400 km northward expansion/migration of the EAM. The lake record is highly correlated with both northern and southern Chinese cave deposit isotope records, supporting rainfall “intensity based” interpretations of these deposits as opposed to an alternative “water vapor sourcing” interpretation. These results indicate that EAM intensity and the northward extent covary on orbital and millennial timescales. The termination of wet conditions at 5.5 ka BP (˜35 m lake drop) triggered a large cultural collapse of Early Neolithic cultures in north China, and possibly promoted the emergence of complex societies of the Late Neolithic.

  4. Northward extent of East Asian monsoon covaries with intensity on orbital and millennial timescales.

    Science.gov (United States)

    Goldsmith, Yonaton; Broecker, Wallace S; Xu, Hai; Polissar, Pratigya J; deMenocal, Peter B; Porat, Naomi; Lan, Jianghu; Cheng, Peng; Zhou, Weijian; An, Zhisheng

    2017-02-21

    The magnitude, rate, and extent of past and future East Asian monsoon (EAM) rainfall fluctuations remain unresolved. Here, late Pleistocene-Holocene EAM rainfall intensity is reconstructed using a well-dated northeastern China closed-basin lake area record located at the modern northwestern fringe of the EAM. The EAM intensity and northern extent alternated rapidly between wet and dry periods on time scales of centuries. Lake levels were 60 m higher than present during the early and middle Holocene, requiring a twofold increase in annual rainfall, which, based on modern rainfall distribution, requires a ∼400 km northward expansion/migration of the EAM. The lake record is highly correlated with both northern and southern Chinese cave deposit isotope records, supporting rainfall "intensity based" interpretations of these deposits as opposed to an alternative "water vapor sourcing" interpretation. These results indicate that EAM intensity and the northward extent covary on orbital and millennial timescales. The termination of wet conditions at 5.5 ka BP (∼35 m lake drop) triggered a large cultural collapse of Early Neolithic cultures in north China, and possibly promoted the emergence of complex societies of the Late Neolithic.

  5. Restoration of optimal ellipsoid left ventricular geometry: lessons learnt from in silico surgical modelling.

    Science.gov (United States)

    Adhyapak, Srilakshmi M; Menon, Prahlad G; Rao Parachuri, V

    2014-02-01

    Several issues that are inherent in the surgical techniques of surgical ventricular restoration (SVR) need specialized devices or techniques to overcome them, which may not always result in optimal outcomes. We used a non-invasive novel in silico modelling technique to study left ventricular (LV) morphology and function before and after SVR. The cardiac magnetic resonance imaging derived actual pre- and postoperative endocardial morphology and function was compared with the in silico analysis of the same. Cardiac magnetic resonance steady state free precession (SSFP) cine images were employed to segment endocardial surface contours over the cardiac cycle. Using the principle of Hausdorff distance to examine phase-to-phase regional endocardial displacement, dyskinetic/akinetic areas were identified at the instant of peak basal contraction velocity. Using a three-dimensional (3D) surface clipping tool, the maximally scarred, dyskinetic or akinetic LV antero-apical areas were virtually resected and a new apex was created. A virtual rectangular patch was created upon the clipped surface LV model by 3D Delaunay triangulation. Presurgical endocardial mechanical function quantified from cine cardiac magnetic resonance, using a technique of spherical harmonics (SPHARM) surface parameterization, was applied onto the virtually clipped and patched LV surface model. Finally, the in silico model of post-SVR LV shape was analysed for quantification of regional left ventricular volumes (RLVVs) and function. This was tested in 2 patients with post-myocardial infarction antero-apical LV aneuryms. Left ventricular mechanical dysynchrony was evaluated by RLVV analysis of pre-SVR, in silico post-SVR and actual post-SVR LV endocardial surface data. Following exclusion of the scarred areas, the virtual resected LV model demonstrated significantly lesser areas of akinesia. The decreases in regional LV volumes in the in silico modelling were significant and comparable with the actual

  6. Fascin expression in cholesteatoma: correlation with destruction of the ossicular chain and extent of disease.

    Science.gov (United States)

    Binnetoglu, A; Sari, M; Baglam, T; Erbarut Seven, I; Yumusakhuylu, A C; Topuz, M F; Batman, C

    2015-08-01

    Fascin is an actin-bundling protein found in cell membrane protrusions and increases cell motility. The expression of fascin in epithelial neoplasms has been described only recently. No data are available concerning the role of this protein in invasive cholesteatoma. Thus, we investigated the expression of fascin in cholesteatoma tissue and the relationship between fascin expression and intraoperative evaluation of the destruction of the ossicular chain and extent of disease. Cholesteatoma specimens of 28 patients and external auditory canal (EAC) skin specimens of the same patients (as the control group) were collected from mastoidectomies. Immunohistochemical technique was used to investigate the fascin expression in all cholesteatoma tissues and EAC skin specimens. Immunohistochemical staining was assessed semiquantitatively based on the thickness of epithelium. SPSS software version 16.0 (SPSS Inc., Chicago, IL, USA) was performed to statistically analyse the relationships between fascin expression and intraoperative evaluation destruction of ossicular chain and extent of the disease. Immunohistochemically, there was no or very low fascin expression observed in normal epithelial cells of EAC skin, while expressed in cholesteatoma tissue. Also, fascin expression in cholesteatoma tissues was significantly correlated with destruction of ossicular chain and extent of the disease. Fascin expression is usually found in cholesteatoma epithelium and is correlated with destruction of the ossicular chain and extent of disease. Considering all of the correlations between the clinical and histopathological findings, 'fascin immunoexpression scoring' may be used for histological grading of cholesteatoma. © 2015 John Wiley & Sons Ltd.

  7. A report on the extent of radioisotope usage in Malaysia

    International Nuclear Information System (INIS)

    1983-04-01

    A market survey was carried out to study the extent of radioisotope usage in Malaysia. From the survey, the radioisotopes and their activities/quantities that are used in Industry, Medicine and Research were identified. The radioisotopes that are frequently needed or routinely used were also determined and this formed the basis of the recommendations put forward in this report. It is proposed that PUSPATI adopt the concept of a Distribution Centre in order to provide a service to the Malaysian community. (author)

  8. Microstructure and Ductility-Dip Cracking Susceptibility of Circumferential Multipass Dissimilar Weld Between 20MND5 and Z2CND18-12NS with Ni-Base Filler Metal 52

    Science.gov (United States)

    Qin, Renyao; Duan, Zhaoling; He, Guo

    2013-10-01

    The large circumferential multipass dissimilar weld between 20MND5 steel and Z2CND18-12NS stainless steel welded with FM52 filler material was investigated in terms of the diluted composition, the grain boundary precipitation, and the ductility-dip cracking (DDC) susceptibility of the weld. The diluted composition of the weld is composed of 37 to 47 pct Ni, 21 to 24 pct Cr, and 28 to 40 pct Fe, which are inhomogeneous along the depth and over the width of the deep weld. The carbon content has a distribution in the region of the surface weld from a high level (~0.20 pct) in the zone near 20MND5 steel to a normal level (~0.03 pct) in the zone near Z2CND18-12NS stainless steel. The carbon distribution is corresponding to the grain boundary carbides. The minimum threshold strains for DDC occur in the temperature range of 1223 K to 1323 K (950 °C to 1050 °C), which are 0.5, 0.35, and 0.4 pct for the root weld, middle region, and the surface weld, respectively. The dissimilar weld has the largest susceptibility to the DDC compared to the filler metal 52 and the Inconel 690.

  9. Flood extent mapping for Namibia using change detection and thresholding with SAR

    International Nuclear Information System (INIS)

    Long, Stephanie; Fatoyinbo, Temilola E; Policelli, Frederick

    2014-01-01

    A new method for flood detection change detection and thresholding (CDAT) was used with synthetic aperture radar (SAR) imagery to delineate the extent of flooding for the Chobe floodplain in the Caprivi region of Namibia. This region experiences annual seasonal flooding and has seen a recent renewal of severe flooding after a long dry period in the 1990s. Flooding in this area has caused loss of life and livelihoods for the surrounding communities and has caught the attention of disaster relief agencies. There is a need for flood extent mapping techniques that can be used to process images quickly, providing near real-time flooding information to relief agencies. ENVISAT/ASAR and Radarsat-2 images were acquired for several flooding seasons from February 2008 to March 2013. The CDAT method was used to determine flooding from these images and includes the use of image subtraction, decision-based classification with threshold values, and segmentation of SAR images. The total extent of flooding determined for 2009, 2011 and 2012 was about 542 km 2 , 720 km 2 , and 673 km 2 respectively. Pixels determined to be flooded in vegetation were typically <0.5% of the entire scene, with the exception of 2009 where the detection of flooding in vegetation was much greater (almost one third of the total flooded area). The time to maximum flooding for the 2013 flood season was determined to be about 27 days. Landsat water classification was used to compare the results from the new CDAT with SAR method; the results show good spatial agreement with Landsat scenes. (paper)

  10. The relation between pain extent and quality-of-life, psychological factors and neck funktion in patients with chronic neck pain

    DEFF Research Database (Denmark)

    Ris Hansen, Inge; Barbero, Marco; Falla, Deborah

    factors and/or decreased function of the involved body parts. Purpose: To study the relation between pain extent with 1) quality of life, 2) kinesiophobia, depression, 3) cervical muscle function and mobility and additionally the relation of pain extent with the origin of pain being traumatic or non...... of Kinesiophobia (TSK), Beck Depression Inventory-II (BDI-ll), Neck Disability Index (NDI) and clinical tests: Craniocervical Flexion Test (CCFT), Cervical Extension Test (CE), and Cervical Range of Motion (CROM). Results: Significant positive correlations were observed between pain extent and NDI (r = 0.33; p... to the origin being traumatic or non-traumatic. Conclusion: Pain extent extracted from pain drawings are moderately correlated with patient-reported neck function, and weakly correlated with depression, kinesiophobia and cervical clinical tests. In clinical decision-making, pain extent may indicate reduced neck...

  11. Desensitizing Flame Structure and Exhaust Emissions to Flow Parameters in an Ultra-Compact Combustor

    Science.gov (United States)

    2012-03-22

    circumferential cavity and the core flow. Radtke [16] explored the effects of operating the RVC facing into and away from the circumferential flow on the AFRL...into the circumferential flow if it was located on the opposite side of the vane. Radtke noticed minimal differences in bulk emission performance, but...did note that on average the combustion efficiency was slightly higher when the RVC was facing into the circumferential flow direction. Radtke also

  12. Catheter ablation in the treatment of electrical storm: Integrative review

    Directory of Open Access Journals (Sweden)

    Ricardo Teixeira Leal

    2017-09-01

    Conclusion: Catheter ablation is the initial therapy for patients with ischemic cardiomyopathy (ICM and ES. The endocardial approach presents more relevant success rates than the other therapeutic methods presented.

  13. A novel method to calculate the extent and amount of drug transported into CSF after intranasal administration.

    Science.gov (United States)

    Shi, Zhenqi; Zhang, Qizhi; Jiang, Xinguo

    2005-01-31

    The aim of this paper is to establish a novel method to calculate the extent and amount of drug transported to brain after administration. The cerebrospinal fluid (CSF) was chosen as the target region. The intranasal administration of meptazinol hydrochloride (MEP) was chosen as the model administration and intravenous administration was selected as reference. According to formula transform, the extent was measured by the equation of X(A)CSF, infinity/X0 = Cl(CSF) AUC(0-->infinity)CSF/X0 and the drug amount was calculated by multiplying the dose with the extent. The drug clearance in CSF (Cl(CSF)) was calculated by a method, in which a certain volume of MEP solution was injected directly into rat cistern magna and then clearance was assessed as the reciprocal of the zeroth moment of a CSF level-time curve normalized for dose. In order to testify the accurateness of the method, 14C-sucrose was chosen as reference because of its impermeable characteristic across blood-brain barrier (BBB). It was found out that the MEP concentrations in plasma and CSF after intranasal administration did not show significant difference with those after intravenous administration. However, the extent and amount of MEP transported to CSF was significantly lower compared with those to plasma after these two administrations. In conclusion, the method can be applied to measure the extent and amount of drug transported to CSF, which would be useful to evaluate brain-targeting drug delivery.

  14. Extent of the Immirzi ambiguity in quantum general relativity

    International Nuclear Information System (INIS)

    Marugan, Guillermo A Mena

    2002-01-01

    The Ashtekar-Barbero formulation of general relativity admits a one-parameter family of canonical transformations that preserves the expressions of the Gauss and diffeomorphism constraints. The loop quantization of the connection formalism based on each of these canonical sets leads to different predictions. This phenomenon is called the Immirzi ambiguity. It has been recently argued that this ambiguity could be generalized to the extent of a spatially dependent function instead of a parameter. This would ruin the predictability of loop quantum gravity. We prove that such expectations are not realized, so that the Immirzi ambiguity introduces exclusively a freedom in the choice of a real number. (letter to the editor)

  15. Extent of linkage disequilibrium in the domestic cat, Felis silvestris catus, and its breeds.

    Directory of Open Access Journals (Sweden)

    Hasan Alhaddad

    Full Text Available Domestic cats have a unique breeding history and can be used as models for human hereditary and infectious diseases. In the current era of genome-wide association studies, insights regarding linkage disequilibrium (LD are essential for efficient association studies. The objective of this study is to investigate the extent of LD in the domestic cat, Felis silvestris catus, particularly within its breeds. A custom illumina GoldenGate Assay consisting of 1536 single nucleotide polymorphisms (SNPs equally divided over ten 1 Mb chromosomal regions was developed, and genotyped across 18 globally recognized cat breeds and two distinct random bred populations. The pair-wise LD descriptive measure (r(2 was calculated between the SNPs in each region and within each population independently. LD decay was estimated by determining the non-linear least-squares of all pair-wise estimates as a function of distance using established models. The point of 50% decay of r(2 was used to compare the extent of LD between breeds. The longest extent of LD was observed in the Burmese breed, where the distance at which r(2 ≈ 0.25 was ∼380 kb, comparable to several horse and dog breeds. The shortest extent of LD was found in the Siberian breed, with an r(2 ≈ 0.25 at approximately 17 kb, comparable to random bred cats and human populations. A comprehensive haplotype analysis was also conducted. The haplotype structure of each region within each breed mirrored the LD estimates. The LD of cat breeds largely reflects the breeds' population history and breeding strategies. Understanding LD in diverse populations will contribute to an efficient use of the newly developed SNP array for the cat in the design of genome-wide association studies, as well as to the interpretation of results for the fine mapping of disease and phenotypic traits.

  16. Extent of availability and utilization of law reports by law students in ...

    African Journals Online (AJOL)

    This study investigates the extent of availability and utilization of law reports by final year lawstudents in the Universities of Uyo and Calabar law libraries. Survey research design was adopted for the study. A total of 450 under graduate final year Law students projects were examined to determine thefrequencyofcitations of ...

  17. The visual extent of an object: suppose we know the object locations

    NARCIS (Netherlands)

    Uijlings, J.R.R.; Smeulders, A.W.M.; Scha, R.J.H.

    2012-01-01

    The visual extent of an object reaches beyond the object itself. This is a long standing fact in psychology and is reflected in image retrieval techniques which aggregate statistics from the whole image in order to identify the object within. However, it is unclear to what degree and how the visual

  18. Influence of heat input and radius to pipe thickness ratio on the residual stresses in circumferential arc welded pipes of API X46 steels

    International Nuclear Information System (INIS)

    Hemmatzadeh, Majid; Moshayedi, Hessamoddin; Sattari-Far, Iradj

    2017-01-01

    The present work aims to study residual stresses caused by circumferentially welding of two similar API X46 steel pipes by means of finite element modeling. Considering the metallurgical phase transformations and through thermal-mechanical uncoupled analysis, the 3D modeling was carried out by SYSWELD software. Materialistic thermal and mechanical properties of all phases were defined in terms of temperature as well as phase transformation properties. Residual stress was measured through hole-drilling method. The obtained results were used to verify the finite element model. By means of full factorial experiment designing method, effects of heat input and radius to pipe thickness ratio on maximum values of hoop and axial residual stresses were investigated. The effect of each factor was studied in 3 levels and by 9 experiments. Results of statistical analysis revealed that increase in heat input and radius-thickness ratio would lead to higher values of maximum hoop and axial residual stresses. However, interactions of high level of heat input and a low level of radius-thickness ratio increased inter-pass temperature and consequently caused a sudden raise in maximum values of residual stresses. - Highlights: • A FEM model was developed to simulate welding considering phase transformations. • The obtained residual stresses were validated by experiments. • Effect of heat input and radius-to-thickness ratio on residual stress were investigated. • Increasing heat input for 100% caused increasing hoop and axial residual stress until 200%. • Interaction of high heat input and low R/t causes a sudden increase in axial residual stresses.

  19. The Role of Deposition in Limiting the Hazard Extent of Dense-Gas Plumes

    Energy Technology Data Exchange (ETDEWEB)

    Dillon, M B

    2008-05-11

    Accidents that involve large (multi-ton) releases of toxic industrial chemicals and form dense-gas clouds often yield far fewer fatalities, casualties and environmental effects than standard assessment and emergency response models predict. This modeling study, which considers both dense-gas turbulence suppression and deposition to environmental objects (e.g. buildings), demonstrates that dry deposition to environmental objects may play a significant role in reducing the distance at which adverse impacts occur - particularly under low-wind, stable atmospheric conditions which are often considered to be the worst-case scenario for these types of releases. The degree to which the released chemical sticks to (or reacts with) environmental surfaces is likely a key parameter controlling hazard extents. In all modeled cases, the deposition to vertical surfaces of environmental objects (e.g. building walls) was more efficient in reducing atmospheric chemical concentrations than deposition to the earth's surface. This study suggests that (1) hazard extents may vary widely by release environment (e.g. grasslands vs. suburbia) and release conditions (e.g. sunlight or humidity may change the rate at which chemicals react with a surface) and (2) greenbelts (or similar structures) may dramatically reduce the impacts of large-scale releases. While these results are demonstrated to be qualitatively consistent with the downwind extent of vegetation damage in two chlorine releases, critical knowledge gaps exist and this study provides recommendations for additional experimental studies.

  20. Strategic environmental assessment in tourism planning - Extent of application and quality of documentation

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho Lemos, Clara, E-mail: clara@sc.usp.br [Environmental Engineering Science, Engineering School of Sao Carlos, University of Sao Paulo, Av. Trabalhador Saocarlense, 400, Caixa Postal 292, Sao Carlos, Sao Paulo, 13566-590 (Brazil); Fischer, Thomas B., E-mail: fischer@liverpool.ac.uk [Department of Civic Design, University of Liverpool, 74 Bedford Street South, Liverpool, L69 7ZQ (United Kingdom); Pereira Souza, Marcelo, E-mail: mps@usp.br [Environmental Engineering Science, Engineering School of Sao Carlos, University of Sao Paulo, Av. Trabalhador Saocarlense, 400, Caixa Postal 292, Sao Carlos, Sao Paulo, 13566-590 (Brazil)

    2012-07-15

    Strategic environmental assessment (SEA) has been applied throughout the world in different sectors and in various ways. This paper reports on results of a PhD research on SEA applied to tourism development planning, reflecting the situation in mid-2010. First, the extent of tourism specific SEA application world-wide is established. Then, based on a review of the quality of 10 selected SEA reports, good practice, as well as challenges, trends and opportunities for tourism specific SEA are identified. Shortcomings of SEA in tourism planning are established and implications for future research are outlined. - Highlights: Black-Right-Pointing-Pointer The extent of tourism specific SEA practice is identified. Black-Right-Pointing-Pointer Selected SEA/Tourism reports are evaluated. Black-Right-Pointing-Pointer SEA application to tourism planning is still limited. Black-Right-Pointing-Pointer A number of shortcomings can be pointed out.