Antibiotic resistance of fecal coliforms after long-term withdrawal of therapeutic and subtherapeutic antibiotic use in a swine herd.  

UK PubMed Central (United Kingdom)

Tetracycline resistance of fecal coliforms isolated from swine decreased from 82 to 42%, a decrease of less than 50%, after the use of all forms of antimicrobial agents were discontinued in the herd...Full Text Available

1983-12-01

2

Sensitivity of Freshly Isolated Bacterial Pathogens to Certain Antibiotics and Nitrofurazone  

UK PubMed Central (United Kingdom)

The results of antibiotic tests on bacterial pathogens freshly isolated from avian tissues and bovine milk are presented. Coliform isolates from the avian species showed an increased resistance to...Full Text Available

1969-01-01

3

Prevention of clinical coliform mastitis in dairy cows by a mutant Escherichia coli vaccine.  

UK PubMed Central (United Kingdom)

A prospective cohort study was undertaken in two commercial California dairies. The treatment group, 246 cows, received three doses of a whole cell bacterin of J5 Escherichia coli (mutant of E. coli...Full Text Available

1989-07-01

4

Identification of immune genes and proteins involved in the response of bovine mammary tissue to Staphylococcus aureus infection  

UK PubMed Central (United Kingdom)

BackgroundMastitis in dairy cattle results from infection of mammary tissue by a range of micro-organisms but principally coliform bacteria and Gram positive bacteria such as Staphylococcus...Full Text Available

5

Microbial indicators of environmental water pollution. Mizu kankyo ni okeru biseibutsu shihyo  

Energy Technology Data Exchange (ETDEWEB)

Microbial indicators in the environmental water are categorized as follows. 1. Index for pathogenic microbial contamination, especially enteric canal based ones. 2. Index for the ordinary microbial contamination. 3. Index for nutritive assessment. 4. Index for the treating effect of final effluent discharged into an environmental water. 5. Index for distinction of of the contamination source. Above 1 and 2'' are among the indices which cannot be replaced by other physico-chemical substances or indices. Up to the present time, 1'' is assessed by a coliform group and 2'' by the bacteria. Recently, however, the status on the microbial contamination of the environmental water is changing, thus urging the reexamination of the assessment systems. This report describes the following items. Characteristics and the elements of the indices (enteric canal based pathogenic microbial contamination); indices under examination ...

1990-08-10

6

Series of surveys for enteric viruses and indicator organisms in Tokyo Bay after an event of combined sewer overflow.  

Science.gov (United States)

Combined sewer overflows (CSOs) have been recognised as one of the serious sources of pollution to the water environment during rain events, although field surveys to investigate the effect of their magnitude and duration on receiving waters have been very limited. The fates of enteric viruses (norovirus G1, G2, enteroviruses) and coliforms were determined in the wastewater treatment plant on a fine day and on a rainy day. Not all microorganisms were reduced in the primary treatment, but were reduced in the secondary treatment. Occurrences of enteric viruses and levels of coliforms were surveyed in the receiving coastal area after a CSO event, with the profiles of the enteric viruses in the coastal seawater being almost at the same positive ratio for 4 d after the CSO event. PMID:15318519

2004-01-01

7

Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico  

Energy Technology Data Exchange (ETDEWEB)

Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm water detection tanks, gates, pumping stations, etc)., the interceptor, the WWTP and the receiving waters. Only an integral planning of ...

2005-07-01

8

Development of a new tool for predicting water quality. Verification on a stretch of the river Ebro; Desarrollo de una nueva herramienta para la prediccion de la calidad del agua. Verificacion en un tramo del rio Ebro  

Energy Technology Data Exchange (ETDEWEB)

The Water Frame work Directive (December 2000) proposes integrated water management in regard to both quality and quality. A mathematical model has therefore been produced at the CEIT and EPTISA research centre, in collaboration with the Ebro Hydrographic. Confederation (CHE), to predict water quality and thus begin integrated management of it in the river basins. A description is given of the characteristics of the simulation tool. The hydraulic model is based on the numerical (weighted, four-point implicit) resolution of the complete Saint Venant equations. The quality model is based on the IWA River Water Quality Model Number 1 which has clear advantages (consistency, mass balance and easy integration with the biological models of the waste water treatment plants and the collector networks compared to traditional models. The experimental validation, which includes calibration in wintertime of the hydraulic and quality models most representative coefficients was assessed on the basis ...

2004-07-01

9

Antimicrobial silver-montmorillonite nanoparticles to prolong the shelf life of fresh fruit salad  

British Library Electronic Table of Contents (United Kingdom)

In this work, silver-montmorillonite (Ag-MMT) antimicrobial nanoparticles have been obtained by allowing silver ions from nitrate solutions to replace the Na^+ of natural montmorillonite and then to be reduced by a thermal treatment. Ag-MMT were used as active antimicrobial compounds to improve the shelf life of fresh fruit salad. In order to assess their influence on product shelf life, sensorial and microbiological quality has been monitored during the storage. The microbiological quality was determined by monitoring the principal spoilage microorganisms (mesophilic and psychrotrophic bacteria, coliforms, lactic acid bacteria, yeasts and molds). Additionally, the evolution of sensorial quality was assessed by monitoring color, odor, firmness and product overall quality. The Ag-MMT nanopa...

2011-01-01

10

Active packaging of ground beef patties by edible zein films incorporated with partially purified lysozyme and Na2EDTA  

British Library Electronic Table of Contents (United Kingdom)

Summary In this study, antimicrobial activity of zein films incorporated with partially purified lysozyme and disodium ethylenediaminetetraacetic acid (Na2EDTA) has been tested on selected pathogenic bacteria and refrigerated ground beef patties. The developed films containing 700-g-cm-2 lysozyme and 300-g-cm-2 Na2EDTA showed antimicrobial activity on Listeria monocytogenes, Escherichia coli O157:H7, and Salmonella typhimurium. The application of lysozyme and Na2EDTA incorporated zein films on beef patties significantly decreased total viable counts (TVC) and total coliform counts after 5-days of storage compared to those of control patties (P-2EDTA or Na2EDTA alone significantly slowed down the oxidative changes in patties during storage (P-P-2EDTA for active packaging of refrigerated mea...

2011-01-01

11

Qualitative aspects in the projects that are developed in the Instituto de Investigaciones Electricas; Aspectos cualitativos en los proyectos que se desarrollan en el Instituto de Investigaciones Electricas  

Energy Technology Data Exchange (ETDEWEB)

The globalization of markets has generated more options of purchase of all type of goods and services, these options have generated opportunities and threats for all the companies and have looked for the satisfaction of the client as a strategy to remain or incursion into the global market. The Instituto de Investigaciones Electricas (IIE) is not the exception and therefore it looks for the identification of the qualitative aspects and to systematize its application in the projects that executes by means of the implantation of a system of quality assurance based on the series of ISO 9000 Standards. Some examples are described to identify the qualitative aspects of the projects that are developed in the Institute. [Spanish] La globalizacion de los mercados ha generado mas opciones de compra de todo tipo de bienes y servicios, dichas opciones han generado oportunidades y amenazas para todas las empresas y se ha buscado satisfacer al cliente como estrategia para permanecer o incursionar ...

1999-07-01

12

Quality of water and time-of-travel in Bakers Creek near Clinton, Mississippi. [Bakers Creek  

Energy Technology Data Exchange (ETDEWEB)

A short-term intensive quality-of-water study was conducted during a period of generally low streamflow in Bakers Creek and its tributary, Lindsey Creek, near Clinton, Mississippi. During the September 15-18, 1980 study, dissolved oxygen concentrations in Bakers Creek were less than 5 milligrams per liter. The specific conductance, 5-day biochemical oxygen demand, nutrient concentrations, and bacteria densities in Bakers Creek decreased downstream through the study reach. The mean specific conductance decreased from 670 to 306 microhms per centimeter. The 5-day biochemical oxygen demand decreased from 19 to 2.8 milligrams per liter. The mean total nitrogen and phosphorous concentrations decreased from 10 and 7.1 to 1.0 and 0.87 milligram per litter, respectively. The maximum fecal bacteria decreased from 7200 to 400 colonies per 100 milliliter. The concentrations of mercury, iron, and manganese in a sample collected at the downstream site exceeded recommended limits. Diazinon and 2,4-D ...

1982-01-01

13

Environmental and plant effects of sewage sludge application to forests and pastures  

Energy Technology Data Exchange (ETDEWEB)

Digested sewage sludge was applied to pastures and tree plantations at 19 to 44 Mg/ha (dry weight) as part of a municipal sludge disposal program. The sludge had low concentrations of heavy metals and traces of /sup 137/Cs and /sup 60/Co. Monitoring of soils, soil solutions, and runoff indicated that N, P, heavy metals, and radionuclides were largely retained in the upper 15cm of the soil. Soil solutions had elevated NO/sub 3//sup /minus// concentrations often >100 mg/L, but no significant increases in groundwater NO/sub 3//sup /minus// were found during the first year. Runoff from active sites had elevated concentrations of NO/sub 3//sup /minus// (20--30 mg/L), soluble P (1 mg/L), BOD/sub 5/ (5--30 mg/L), and fecal coliform (up to 14,000 colonies per 100 ml), not unlike runoff from pastures with cattle. Enrichment of organic N (2 times), available (inorganic) N (5 to 10 times), and Bray-P in the upper soils persisted for several years following sludge ...

1989-01-01