WorldWideScience

Sample records for blood analysis

  1. Correlation between arterial blood gas analysis and peripheral blood gas analysis in acid-base unbalance state

    Directory of Open Access Journals (Sweden)

    Hyun Lee Kim

    2012-06-01

    Full Text Available Acid-base unbalance is most common problem in severe ill patient, especially in condition of abnormal renal function state. Acid-base unbalances are respiratory acidosis, respiratory alkalosis, metabolic acidosis, and metabolic alkalosis. Metabolic acidosis is frequently appeared in clinical state. Arterial blood gas analysis is considered as a basic test to the intensive care unit patient and emergency state. Recently some researches were done, comparing with arterial blood gas analysis and venous blood gas analysis. Because of venous blood sampling is safer than arterial blood gas analysis, and beside not so different among them for detecting pH, pCO2, HCO3, except pO2 measuring. This research was done in emergency room, and for explaining no different between arterial blood gas analysis and peripheral blood gas analysis result in acid-base unbalance state patient. Especially in kidney functions decreased state. : The study was done from March, 2010 to January, 2011. The object was 89 peoples who came to emergency room for treating internal medicine problem. (Women 53, average age: 66.7±12.1 Then compare between arterial blood gas analysis and peripheral blood gas analysis. Result: The mean arterial minus venous difference for pH, pCO2, and bicarbonate was −0.0170, 2.6528, and 0.6124. Bland-Altman plot was done for predicting agreement of two groups, and the scale was pH −2.95 to 4.17, pCO2 −4.45 to 9.76, bicarbonate −2.95 to 4.16, in 95% relative. Conclusion: The peripheral blood gas pH, pCO2, bicarbonate level is almost same as arterial blood gas analysis results. And enough to measuring acid-base unbalance state, in absent of arterial blood testing.

  2. Polynomial analysis of ambulatory blood pressure measurements

    NARCIS (Netherlands)

    Zwinderman, A. H.; Cleophas, T. A.; Cleophas, T. J.; van der Wall, E. E.

    2001-01-01

    In normotensive subjects blood pressures follow a circadian rhythm. A circadian rhythm in hypertensive patients is less well established, and may be clinically important, particularly with rigorous treatments of daytime blood pressures. Polynomial analysis of ambulatory blood pressure monitoring

  3. Blood analysis in newborn donkeys: hematology, biochemistry, and blood gases analysis.

    Science.gov (United States)

    Veronesi, M C; Gloria, A; Panzani, S; Sfirro, M P; Carluccio, A; Contri, A

    2014-07-15

    The knowledge of reference ranges for hematologic, biochemical, and blood gas parameters in the different species and the influence of breed and age on them is a fundamental tool for the clinician. For this reason, the aim of this study was to evaluate the age-related changes of hematologic and biochemical parameters in Martina Franca donkey foals during the first 3 weeks of life and of blood gases during the first 24 hours of age. Fifteen healthy donkey foals were enrolled; blood samples were collected from each foal at 10 minutes after birth, 1 hour after the first and second suckles, 12 and 24 hours after birth, daily from Day 2 to 7, and at Days 10, 14, and 21 of life. Erythrocytes, leukocytes, and platelets counts were assessed; also metabolic (alanine aminotransferase, aspartate aminotransferase, gamma glutamyl transferase, creatinphospokinase, lactate dehydrogenase, alkaline phosphatase, glucose, blood urea nitrogen, creatinine, total proteins, albumins, cholesterol, and total bilirubin) and electrolytic parameters (Ca, P, Mg, Na, K, and Cl) were evaluated. Finally, blood gases and metabolic parameters (pH, pCO2, pO2, sO2, TCO2, HCO3, lactate, and base excess) on venous blood were assessed with a portable analyzer. A statistical analysis to evaluate the influence of age and sex was performed. Several differences were found between sampling times, demonstrating that age influences these parameters. Moreover differences were found compared with data reported in literature for donkey foals of another species, horse foals, and adult donkeys. Although a great interindividual variation for some parameters exists, this study demonstrated that interval references should be addressed not only to different species, but also to specific breeds and to the neonatal period. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Computational Analysis of Human Blood Flow

    Science.gov (United States)

    Panta, Yogendra; Marie, Hazel; Harvey, Mark

    2009-11-01

    Fluid flow modeling with commercially available computational fluid dynamics (CFD) software is widely used to visualize and predict physical phenomena related to various biological systems. In this presentation, a typical human aorta model was analyzed assuming the blood flow as laminar with complaint cardiac muscle wall boundaries. FLUENT, a commercially available finite volume software, coupled with Solidworks, a modeling software, was employed for the preprocessing, simulation and postprocessing of all the models.The analysis mainly consists of a fluid-dynamics analysis including a calculation of the velocity field and pressure distribution in the blood and a mechanical analysis of the deformation of the tissue and artery in terms of wall shear stress. A number of other models e.g. T branches, angle shaped were previously analyzed and compared their results for consistency for similar boundary conditions. The velocities, pressures and wall shear stress distributions achieved in all models were as expected given the similar boundary conditions. The three dimensional time dependent analysis of blood flow accounting the effect of body forces with a complaint boundary was also performed.

  5. Does chocolate reduce blood pressure? A meta-analysis

    Directory of Open Access Journals (Sweden)

    Ried Karin

    2010-06-01

    Full Text Available Abstract Background Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. Methods We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive. Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P Results Fifteen trial arms of 13 assessed studies met the inclusion criteria. Pooled meta-analysis of all trials revealed a significant blood pressure-reducing effect of cocoa-chocolate compared with control (mean BP change ± SE: SBP: -3.2 ± 1.9 mmHg, P = 0.001; DBP: -2.0 ± 1.3 mmHg, P = 0.003. However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 ± 3.0 mmHg; P = 0.0009; DBP: -2.7 ± 2.2 mm Hg, P = 0.01, while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 ± 2.3 mmHg, P = 0.17; DBP: -1.3 ± 1.6 mmHg, P = 0.12. Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30

  6. Phase analysis in gated blood pool tomography

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro

    1984-01-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome. (author)

  7. Does chocolate reduce blood pressure? A meta-analysis.

    Science.gov (United States)

    Ried, Karin; Sullivan, Thomas; Fakler, Peter; Frank, Oliver R; Stocks, Nigel P

    2010-06-28

    Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP) for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive). Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P chocolate compared with control (mean BP change +/- SE: SBP: -3.2 +/- 1.9 mmHg, P = 0.001; DBP: -2.0 +/- 1.3 mmHg, P = 0.003). However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 +/- 3.0 mmHg; P = 0.0009; DBP: -2.7 +/- 2.2 mm Hg, P = 0.01), while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 +/- 2.3 mmHg, P = 0.17; DBP: -1.3 +/- 1.6 mmHg, P = 0.12). Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30 mg to 1000 mg in the active treatment groups, and interventions ran for 2 to 18 weeks. Meta-regression analysis found study design and type of control to be borderline significant but possibly indirect predictors

  8. Analysis and optimization of blood-testing procedures.

    NARCIS (Netherlands)

    Bar-Lev, S.K.; Boxma, O.J.; Perry, D.; Vastazos, L.P.

    2017-01-01

    This paper is devoted to the performance analysis and optimization of blood testing procedures. We present a queueing model of two queues in series, representing the two stages of a blood-testing procedure. Service (testing) in stage 1 is performed in batches, whereas it is done individually in

  9. Analysis of RBC-microparticles in stored whole blood bags - a promising marker to detect blood doping in sports?

    Science.gov (United States)

    Voss, Sven Christian; Jaganjac, Morana; Al-Thani, Amna Mohamed; Grivel, Jean-Charles; Raynaud, Christophe Michel; Al-Jaber, Hind; Al-Menhali, Afnan Saleh; Merenkov, Zeyed Ahmad; Alsayrafi, Mohammed; Latiff, Aishah; Georgakopoulos, Costas

    2017-11-01

    Blood doping in sports is prohibited by the World Anti-Doping Agency (WADA). To find a possible biomarker for the detection of blood doping, we investigated the changes in blood stored in CPDA-1 blood bags of eight healthy subjects who donated one unit of blood. Aliquots were taken on days 0, 14, and 35. Platelet-free plasma was prepared and stored at -80°C until analysis on a flow cytometer dedicated for the analysis of microparticles (MPs). Changes in the number of red blood cell (RBC) -MPs were highly significant (p doping control but confirmation by a transfusion study is necessary. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Blood analysis by Raman spectroscopy.

    Science.gov (United States)

    Enejder, Annika M K; Koo, Tae-Woong; Oh, Jeankun; Hunter, Martin; Sasic, Slobodan; Feld, Michael S; Horowitz, Gary L

    2002-11-15

    Concentrations of multiple analytes were simultaneously measured in whole blood with clinical accuracy, without sample processing, using near-infrared Raman spectroscopy. Spectra were acquired with an instrument employing nonimaging optics, designed using Monte Carlo simulations of the influence of light-scattering-absorbing blood cells on the excitation and emission of Raman light in turbid medium. Raman spectra were collected from whole blood drawn from 31 individuals. Quantitative predictions of glucose, urea, total protein, albumin, triglycerides, hematocrit, and hemoglobin were made by means of partial least-squares (PLS) analysis with clinically relevant precision (r(2) values >0.93). The similarity of the features of the PLS calibration spectra to those of the respective analyte spectra illustrates that the predictions are based on molecular information carried by the Raman light. This demonstrates the feasibility of using Raman spectroscopy for quantitative measurements of biomolecular contents in highly light-scattering and absorbing media.

  11. Blood proteins analysis by Raman spectroscopy method

    Science.gov (United States)

    Artemyev, D. N.; Bratchenko, I. A.; Khristoforova, Yu. A.; Lykina, A. A.; Myakinin, O. O.; Kuzmina, T. P.; Davydkin, I. L.; Zakharov, V. P.

    2016-04-01

    This work is devoted to study the possibility of plasma proteins (albumin, globulins) concentration measurement using Raman spectroscopy setup. The blood plasma and whole blood were studied in this research. The obtained Raman spectra showed significant variation of intensities of certain spectral bands 940, 1005, 1330, 1450 and 1650 cm-1 for different protein fractions. Partial least squares regression analysis was used for determination of correlation coefficients. We have shown that the proposed method represents the structure and biochemical composition of major blood proteins.

  12. Using Willie's Acid-Base Box for Blood Gas Analysis

    Science.gov (United States)

    Dietz, John R.

    2011-01-01

    In this article, the author describes a method developed by Dr. William T. Lipscomb for teaching blood gas analysis of acid-base status and provides three examples using Willie's acid-base box. Willie's acid-base box is constructed using three of the parameters of standard arterial blood gas analysis: (1) pH; (2) bicarbonate; and (3) CO[subscript…

  13. [Immunologic risk analysis of blood transfusion: 1991-1998].

    Science.gov (United States)

    Rouger, P; Le Pennec, P Y; Noizat-Pirenne, F

    2000-02-01

    The immunologic risk associated to erythrocyte transfusions is bound to the polymorphism of blood group systems and to the respect of blood transfusion regulations. The results of three studies are presented, which were carried out respectively by the French Society of Blood Transfusion, the National Institute of Blood Transfusion and the National Haemovigilance Network. Two hundred and twenty-seven cases of immunologic accidents are analysed using the Kaplan's interpretation model and the traditional method of process analysis. The results show three critical factors in the occurrence of this type of incident: the relevance of the clinical examinations prescribed, the way in which the biological results are taken into account, and the relationship/exchange of information between private and public hospitals, and blood transfusion centers.

  14. Blood management in total hip replacement: an analysis of factors associated with allogenic blood transfusion.

    Science.gov (United States)

    Wong, Samuel; Tang, Howard; de Steiger, Richard

    2015-06-01

    The aim of this study was to audit the blood transfusion practice throughout the Epworth Healthcare Hospitals for patients undergoing primary total hip replacement (THR). We determined if blood-saving techniques were having an impact on the risk of allogenic blood transfusion and which patients were at risk of receiving allogenic blood transfusion. This study uses a retrospective audit of 787 patients who had undergone primary THR surgery at three Melbourne hospitals: Epworth Richmond, Epworth Eastern and Epworth Freemasons in 2010. Patient demographics, transfusion requirements and blood-conserving techniques were recorded. One hundred and eighty (23%) patients received allogenic blood transfusion and 18 (2.3%) patients received autologous blood transfusion. On multivariate analysis, preoperative anaemia (odds ratio (OR) 4.7, P blood transfusion. Use of spinal anaesthetic was found to be associated with lower risk of transfusion (OR 0.6, P = 0.0180) compared with general anaesthetic alone. Cell saver, acute normovolaemic haemodilution and re-infusion drain tube usage did not have a significant impact on reducing the risk of allogenic blood transfusion. Identification of patients at risk of blood transfusion, correction of preoperative anaemia and a restrictive transfusion policy are important factors to consider in effective perioperative blood management. © 2015 Royal Australasian College of Surgeons.

  15. White blood cell counting analysis of blood smear images using various segmentation strategies

    Science.gov (United States)

    Safuan, Syadia Nabilah Mohd; Tomari, Razali; Zakaria, Wan Nurshazwani Wan; Othman, Nurmiza

    2017-09-01

    In white blood cell (WBC) diagnosis, the most crucial measurement parameter is the WBC counting. Such information is widely used to evaluate the effectiveness of cancer therapy and to diagnose several hidden infection within human body. The current practice of manual WBC counting is laborious and a very subjective assessment which leads to the invention of computer aided system (CAS) with rigorous image processing solution. In the CAS counting work, segmentation is the crucial step to ensure the accuracy of the counted cell. The optimal segmentation strategy that can work under various blood smeared image acquisition conditions is remain a great challenge. In this paper, a comparison between different segmentation methods based on color space analysis to get the best counting outcome is elaborated. Initially, color space correction is applied to the original blood smeared image to standardize the image color intensity level. Next, white blood cell segmentation is performed by using combination of several color analysis subtraction which are RGB, CMYK and HSV, and Otsu thresholding. Noises and unwanted regions that present after the segmentation process is eliminated by applying a combination of morphological and Connected Component Labelling (CCL) filter. Eventually, Circle Hough Transform (CHT) method is applied to the segmented image to estimate the number of WBC including the one under the clump region. From the experiment, it is found that G-S yields the best performance.

  16. Blood Warming and Hemolysis: A Systematic Review With Meta-Analysis.

    Science.gov (United States)

    Poder, Thomas G; Nonkani, Wendyam G; Tsakeu Leponkouo, Élyonore

    2015-07-01

    The use of fluid warmers during blood transfusion is recommended to avoid inducing hypothermia and its harmful effects. Fluid warmers offered by manufacturers can reach temperatures of 43°C. However, the recommendations of national regulatory organizations do not clearly indicate the maximum heating temperature in relation to the risk of hemolysis. To fill this gap, we conducted a systematic review of the literature with meta-analysis. To match clinical practice, this review was limited to fluid warmers that used contact heating; thus, studies that used radiofrequency or microwave heating were excluded. Twenty-four observational studies were included, 17 of which were the subject of a meta-analysis. A preliminary descriptive analysis indicated that multiple factors can influence the level of hemolysis during blood heating with a liquid warmer, including blood age, anticoagulant type, duration of exposure to heat, stirring the blood during heating, and various elements of the circuit through which blood flows (eg, type of infusion pump with pressure and flow, type of microfilter, and type of tubing). Moreover, the duration between sampling and hemolysis assay was a source of heterogeneity among studies, as were the initial free hemoglobin levels in the various experiments. In general, the increase generated by each of these factors other than temperature appears to have been limited except for blood age, which is an important parameter of hemolysis, the length of exposure to heat, and, in some studies, the type of infusion pump used. Regarding the meta-analysis, at temperatures at or less than 43°C and even up to 45-46°C, it appears that blood heating is safe and causes hemolysis only in clinically negligible proportions. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Total reflection x-ray analysis of metals in blood samples

    International Nuclear Information System (INIS)

    Nakamura, Takuya; Matsui, Hiroshi; Kawamata, Masaya

    2009-01-01

    The sample preparation for TXRF (total reflection X-ray fluorescence) quantitative analysis of trace elements in human blood samples was investigated. In the TXRF analysis, a solution sample is dropped and dried on a flat substrate, and then the dried residue is measured. In this case, the dried residue should be flat not to disturb X-ray total reflection on the substrate. In addition, it is required to simply measure the whole blood sample by TXRF method, although a serum is analyzed in many cases. Thus, we studied the optimum conditions of the sample preparation of the whole blood by adding the pure water to apply Hemolysis phenomenon, where blood cells are destroyed due to different of the osmotic pressure, leading to flat residue. It was found that the best S/B ratio was obtained when the whole blood was diluted 8 times with pure water. Moreover, it was investigated the influence of the surface chemical condition of the glass substrate on the shape of the dried reside of the blood sample. When the surface of the glass substrate was hydrophilic, the shape of the dried residues was not uniform, as a result, the quantitative data of TXRF analysis gave a large deviation. On the other hand, when the surface of the glass was hydrophobic, the shape of the residue was almost uniform, as a result, a good reproducibility was obtained. Another problem was an outer ring of the dried residue of the blood. This uneven ring absorbs the primary X-rays, caused to low determined quantitative data. Thus, we tried the heating way of the dropped blood sample at a high temperature of 200 degrees. In this case, the blood sample was dried immediately, and a flat homogeneous dried residue was obtained without the outer ring. Using the optimized conditions for sample preparation, human blood sample was quantitatively measured by TXRF and ICP-AES. A good agreement was obtained in TXRF and ICP-AES determinations; however, the measurement of Cl and Br will be an advantage of TXRF, because

  18. [Economic analysis versus the principle of guaranteed safety in blood transfusion].

    Science.gov (United States)

    Moatti, J P; Loubière, S; Rotily, M

    2000-06-01

    This article shows that policies aimed at reducing risks of infectious agents transmissible through blood unfortunately follow a law of 'diminishing returns': increasing marginal costs have to be devoted for limited reductions in the risks of contamination through blood donations. Therefore, the economic cost-effectiveness analysis is appropriate to identify screening strategies which may minimize costs to reach a certain level of safety. Moreover, economic analysis can contribute to public debates about the level of residual risk that society is willing to accept. Empirical results from French studies about screening for hepatitis C virus (HCV) in individuals who have received blood transfusions and in blood donations are presented to illustrate these points.

  19. Estimating the measurement uncertainty in forensic blood alcohol analysis.

    Science.gov (United States)

    Gullberg, Rod G

    2012-04-01

    For many reasons, forensic toxicologists are being asked to determine and report their measurement uncertainty in blood alcohol analysis. While understood conceptually, the elements and computations involved in determining measurement uncertainty are generally foreign to most forensic toxicologists. Several established and well-documented methods are available to determine and report the uncertainty in blood alcohol measurement. A straightforward bottom-up approach is presented that includes: (1) specifying the measurand, (2) identifying the major components of uncertainty, (3) quantifying the components, (4) statistically combining the components and (5) reporting the results. A hypothetical example is presented that employs reasonable estimates for forensic blood alcohol analysis assuming headspace gas chromatography. These computations are easily employed in spreadsheet programs as well. Determining and reporting measurement uncertainty is an important element in establishing fitness-for-purpose. Indeed, the demand for such computations and information from the forensic toxicologist will continue to increase.

  20. Cost-effective and rapid blood analysis on a cell-phone.

    Science.gov (United States)

    Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan

    2013-04-07

    We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.

  1. A retrospective analysis of blood gases with two different insulin ...

    African Journals Online (AJOL)

    A retrospective analysis of blood gases with two different insulin infusion protocols in patients undergoing cardiovascular surgery. ... In this study, we aimed to look into the effect of glycemic control on arterial blood gas parameters, serum electrolytes, and hemoglobin (Hb). Materials and Methods: We collected data from ...

  2. Red blood cell antigen genotype analysis for 9087 Asian, Asian American, and Native American blood donors.

    Science.gov (United States)

    Delaney, Meghan; Harris, Samantha; Haile, Askale; Johnsen, Jill; Teramura, Gayle; Nelson, Karen

    2015-10-01

    There has yet to be a comprehensive analysis of blood group antigen prevalence in Asian Americans and Native Americans. There may be ethnic differences in blood group frequencies that would result in clinically important mismatches through transfusion. Blood donors who self-identified as Asian or Native American were tested using a single-nucleotide polymorphism (SNP) DNA array (HEA BeadChip kit, Bioarray Solutions Ltd) that predicts expression of 38 human erythrocyte antigens (HEAs) and by serology for ABO, D, C, M, N, Jk(a) , and Jk(b) . The prevalence of blood group antigens was compared to published European prevalence. Discrepancies between SNP-predicted and serology-detected antigens were tallied. A total of 9087 blood donors were tested from nine Asian and Native American heritages. The predicted prevalence of selected antigens in the RHCE, JK, FY, MNS, LU, CO, and DO blood group systems were variable between Asian populations, but overall not significantly different than Europeans. Compared to European frequencies, Kell blood group allele frequencies were significantly different in the Chinese, Native American, Hawaiian/Pacific Islander, South Asian, and Southeast Asian heritage blood donors; Diego antigens Di(a) and Di(b) were different in donors of Native American and South Asian ancestries (p Asian and Native Americans donors. Several ethnic groups exhibited differences in HEA frequencies compared to Europeans. Genotype-serotype discrepancies were detected in all systems studied. © 2015 AABB.

  3. Whole blood analysis rotor assembly having removable cellular sedimentation bowl

    Science.gov (United States)

    Burtis, C.A.; Johnson, W.F.

    1975-08-26

    A rotor assembly for performing photometric analyses using whole blood samples is described. Following static loading of a gross blood sample within a centrally located, removable, cell sedimentation bowl, the red blood cells in the gross sample are centrifugally separated from the plasma, the plasm displaced from the sedimentation bowl, and measured subvolumes of plasma distributed to respective sample analysis cuvettes positioned in an annular array about the rotor periphery. Means for adding reagents to the respective cuvettes are also described. (auth)

  4. Analysis of Arterial and Venous Blood Gases in Healthy Gyr Falcons ( Falco rusticolus ) Under Anesthesia.

    Science.gov (United States)

    Raghav, Raj; Middleton, Rachael; BSc, Rinshiya Ahamed; Arjunan, Raji; Caliendo, Valentina

    2015-12-01

    Arterial and venous blood gas analysis is useful in the assessment of tissue oxygenation and ventilation and in diagnosis of metabolic and respiratory derangements. It can be performed with a relatively small volume of blood in avian patients under emergency situations. Arterial and venous blood gas analysis was performed in 30 healthy gyr falcons ( Falco rusticolus ) under anaesthesia to establish temperature-corrected reference intervals for arterial blood gas values and to compare them to temperature-corrected venous blood gas values with a portable point-of-care blood gas analyzer (i-STAT 1, Abbott Laboratories, Abbott Park, IL, USA). Statistically significant differences were observed between the temperature-corrected values of pH, partial pressure of carbon dioxide (Pco2), and partial pressure of oxygen (Po2) and the corresponding nontemperature-corrected values of these parameters in both arterial and venous blood. Values of temperature-corrected pH, temperature-corrected Pco2, bicarbonate concentrations, and base excess of extra cellular fluid did not differ significantly between arterial and venous blood, suggesting that, in anesthetized gyr falcons, venous blood gas analysis can be used in place of arterial blood gas analysis in clinical situations. Values for hematocrit, measured by the point-of-care analyzer, were significantly lower compared with those obtained by the microhematocrit method.

  5. Non-invasive pulmonary blood flow analysis and blood pressure mapping derived from 4D flow MRI

    Science.gov (United States)

    Delles, Michael; Rengier, Fabian; Azad, Yoo-Jin; Bodenstedt, Sebastian; von Tengg-Kobligk, Hendrik; Ley, Sebastian; Unterhinninghofen, Roland; Kauczor, Hans-Ulrich; Dillmann, Rüdiger

    2015-03-01

    In diagnostics and therapy control of cardiovascular diseases, detailed knowledge about the patient-specific behavior of blood flow and pressure can be essential. The only method capable of measuring complete time-resolved three-dimensional vector fields of the blood flow velocities is velocity-encoded magnetic resonance imaging (MRI), often denoted as 4D flow MRI. Furthermore, relative pressure maps can be computed from this data source, as presented by different groups in recent years. Hence, analysis of blood flow and pressure using 4D flow MRI can be a valuable technique in management of cardiovascular diseases. In order to perform these tasks, all necessary steps in the corresponding process chain can be carried out in our in-house developed software framework MEDIFRAME. In this article, we apply MEDIFRAME for a study of hemodynamics in the pulmonary arteries of five healthy volunteers. The study included measuring vector fields of blood flow velocities by phase-contrast MRI and subsequently computing relative blood pressure maps. We visualized blood flow by streamline depictions and computed characteristic values for the left and the right pulmonary artery (LPA and RPA). In all volunteers, we observed a lower amount of blood flow in the LPA compared to the RPA. Furthermore, we visualized blood pressure maps using volume rendering and generated graphs of pressure differences between the LPA, the RPA and the main pulmonary artery. In most volunteers, blood pressure was increased near to the bifurcation and in the proximal LPA, leading to higher average pressure values in the LPA compared to the RPA.

  6. Screening hypochromism (sieve effect) in red blood cells: a quantitative analysis.

    Science.gov (United States)

    Razi Naqvi, K

    2014-04-01

    Multiwavelength UV-visible spectroscopy, Kramers-Kronig analysis, and several other experimental and theoretical tools have been applied over the last several decades to fathom absorption and scattering of light by suspensions of micron-sized pigmented particles, including red blood cells, but a satisfactory quantitative analysis of the difference between the absorption spectra of suspension of intact and lysed red blood cells is still lacking. It is stressed that such a comparison is meaningful only if the pertinent spectra are free from, or have been corrected for, scattering losses, and it is shown that Duysens' theory can, whereas that of Vekshin cannot, account satisfactorily for the observed hypochromism of suspensions of red blood cells.

  7. A numerical analysis on the curved bileaflet Mechanical Heart Valve (MHV) : leaflet motion and blood flow in an elastic blood vessel

    International Nuclear Information System (INIS)

    Bang, Jin Seok; Kim, Chang Nyung; Choi, Choeng Ryul

    2005-01-01

    In blood flow passing through the Mechanical Heart Valve (MHV) and elastic blood vessel, hemolysis and platelet activation causing thrombus formation can be seen owing to the shear stress in the blood. Also, fracture and deformation of leaflets can be observed depending on the shape and material properties of the leaflets which is opened and closed in a cycle. Hence, comprehensive study is needed on the hemodynamics which is associated with the motion of leaflet and elastic blood vessel in terms of fluid-structure interaction. In this paper, a numerical analysis has been performed for a three-dimensional pulsatile blood flow associated with the elastic blood vessel and curved bileaflet for multiple cycles in light of fluid-structure interaction. From this analysis fluttering phenomenon and rebound of the leaflet have been observed and recirculation and regurgitation have been found in the flow fields of the blood. Also, the pressure distribution and the radial displacement of the elastic blood vessel have been obtained. The motion of the leaflet and flow fields of the blood have shown similar tendency compared with the previous experiments carried out in other studies. The present study can contribute to the design methodology for the curved bileaflet mechanical heart valve. Furthermore, the proposed fluid-structure interaction method will be effectively used in various fields where the interaction between fluid flow and structure are involved

  8. Linearity analysis and comparison study on the epoc® point-of-care blood analysis system in cardiopulmonary bypass patients

    Directory of Open Access Journals (Sweden)

    Jianing Chen

    2016-03-01

    Full Text Available The epoc® blood analysis system (Epocal Inc., Ottawa, Ontario, Canada is a newly developed in vitro diagnostic hand-held analyzer for testing whole blood samples at point-of-care, which provides blood gas, electrolytes, ionized calcium, glucose, lactate, and hematocrit/calculated hemoglobin rapidly. The analytical performance of the epoc® system was evaluated in a tertiary hospital, see related research article “Analytical evaluation of the epoc® point-of-care blood analysis system in cardiopulmonary bypass patients” [1]. Data presented are the linearity analysis for 9 parameters and the comparison study in 40 cardiopulmonary bypass patients on 3 epoc® meters, Instrumentation Laboratory GEM4000, Abbott iSTAT, Nova CCX, and Roche Accu-Chek Inform II and Performa glucose meters.

  9. Microfluidic Cytometer for Complete Blood Count Analysis, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We will fabricate and test microfluidic designs for a micro-electromechanical system based complete blood count (CBC) analysis in separate modules and integrate them...

  10. Regional quality control survey of blood-gas analysis.

    Science.gov (United States)

    Minty, B D; Nunn, J F

    1977-09-01

    We undertook an external quality control survey of blood-gas analysis in 16 laboratories at 13 hospitals. All samples were prepared in the laboratories under investigation by equilibration of blood or serum with gas mixtures of known composition. pH of serum was measured with no significant bias but with an SD of random error 0.026 pH units, which was almost twice the SD of the reference range (0.015). An acceptable random error (half SD of reference range) was not obtained in a longitudinal internal quality control suvey although there were acceptable results for buffer pH in both field and internal surveys. Blood PO2 was measured with no significant bias but with SD of random error 1.38 kPa which reduced to 0.72 kPa by excluding one egregious result. The latter value was just over half of the SD of the reference range (1.2 kPa). PCO2 of blood was also measured without significant bias but with a much smaller SD of random error of 0.28 kPa (by excluding one egregious result), which was again just over half the SD of the reference range (0.51 kPa). Measurements of blood PO2 and PCO2 seem generally acceptable in relation to their respective reference ranges but measurements of pH were unsatisfactory in both internal and external trials.

  11. Hyperspectral imaging and multivariate analysis in the dried blood spots investigations

    Science.gov (United States)

    Majda, Alicja; Wietecha-Posłuszny, Renata; Mendys, Agata; Wójtowicz, Anna; Łydżba-Kopczyńska, Barbara

    2018-04-01

    The aim of this study was to apply a new methodology using the combination of the hyperspectral imaging and the dry blood spot (DBS) collecting. Application of the hyperspectral imaging is fast and non-destructive. DBS method offers the advantage also on the micro-invasive blood collecting and low volume of required sample. During experimental step, the reflected light was recorded by two hyperspectral systems. The collection of 776 spectral bands in the VIS-NIR range (400-1000 nm) and 256 spectral bands in the SWIR range (970-2500 nm) was applied. Pixel has the size of 8 × 8 and 30 × 30 µm for VIS-NIR and SWIR camera, respectively. The obtained data in the form of hyperspectral cubes were treated with chemometric methods, i.e., minimum noise fraction and principal component analysis. It has been shown that the application of these methods on this type of data, by analyzing the scatter plots, allows a rapid analysis of the homogeneity of DBS, and the selection of representative areas for further analysis. It also gives the possibility of tracking the dynamics of changes occurring in biological traces applied on the surface. For the analyzed 28 blood samples, described method allowed to distinguish those blood stains because of time of apply.

  12. Phase analysis in gated blood pool tomography. Detection of accessory conduction pathway

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro (Kanazawa Univ. (Japan). School of Medicine)

    1984-02-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome.

  13. Dried blood spot analysis of creatinine with LC-MS/MS in addition to immunosuppressants analysis

    NARCIS (Netherlands)

    Koster, Remco A.; Greijdanus, Ben; Alffenaar, Jan-Willem C.; Touw, Daan J.

    In order to monitor creatinine levels or to adjust the dosage of renally excreted or nephrotoxic drugs, the analysis of creatinine in dried blood spots (DBS) could be a useful addition to DBS analysis. We developed a LC-MS/MS method for the analysis of creatinine in the same DBS extract that was

  14. Body size and blood pressure: an analysis of Africans and the African diaspora.

    Science.gov (United States)

    Cappuccio, Francesco P; Kerry, Sally M; Adeyemo, Adebowale; Luke, Amy; Amoah, Albert G B; Bovet, Pascal; Connor, Myles D; Forrester, Terrence; Gervasoni, Jean-Pierre; Kaki, Gisela Kimbally; Plange-Rhule, Jacob; Thorogood, Margaret; Cooper, Richard S

    2008-01-01

    Blood pressure is directly and causally associated with body mass index (BMI) in populations worldwide. However, the relationship may vary across BMI in populations of African origin. We compared the relationship between blood pressure and BMI in populations of African origin, using 13 samples from Africa, the Caribbean, the United Kingdom and the United States. We had access to data from individual participants for age, height, weight, blood pressure, and treatment of hypertension. Analysis was restricted to 18,072 participants (age 35-64 years; 44% men). We carried out multivariate regression analysis to estimate the relationship between blood pressure and BMI by country and by sex. The use of antihypertensive treatment was taken into account by exclusion and by sensitivity analysis. There was a positive relationship between both systolic and diastolic blood pressure and BMI. In men the slopes for systolic blood pressure varied from 0.27 mm Hg per kg/m (95% confidence interval = -0.01 to 0.56) in the United States to 1.72 mm Hg per kg/m (95% confidence interval = 0.92 to 2.53) in Ghana (Kumasi). In women, the slopes varied from 0.08 (-0.54 to 0.72) in South Africa to 1.32 (0.98 to 1.66) in the Republic of Congo. Similar variation in trends was seen for diastolic blood pressure. The higher the BMI, the shallower the slopes [-0.10 (-0.15 to -0.06) for systolic, -0.09 (-0.12 to -0.06) for diastolic]. No differences were seen after excluding persons who were being treated for hypertension. Blood pressure and BMI levels vary among populations of the African diaspora. The effect of BMI on blood pressure levels diminishes as BMI increases. These results suggest a complex relationship among excess body weight, adiposity, and energy expenditure.

  15. Effect of melatonin on nocturnal blood pressure: meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Laudon M

    2011-09-01

    Full Text Available Ehud Grossman1,4, Moshe Laudon2, Nava Zisapel2,31Department of Internal Medicine D and Hypertension Unit, The Chaim Sheba Medical Center, Tel-Hashomer, Israel; 2Neurim Pharmaceuticals Ltd, Tel Aviv, Israel and 3Department of Neurobiology, Faculty of Life Sciences, Tel Aviv University, Tel Aviv, Israel; 4Sackler School of Medicine, Tel Aviv University, Tel Aviv, IsraelBackground: Patients with nocturnal hypertension are at higher risk for cardiovascular complications such as myocardial infarction and cerebrovascular insult. Published studies inconsistently reported decreases in nocturnal blood pressure with melatonin.Methods: A meta-analysis of the efficacy and safety of exogenous melatonin in ameliorating nocturnal blood pressure was performed using a random effects model of all studies fitting the inclusion criteria, with subgroup analysis of fast-release versus controlled-release preparations.Results: Seven trials (three of controlled-release and four of fast-release melatonin with 221 participants were included. Meta-analysis of all seven studies did not reveal significant effects of melatonin versus placebo on nocturnal blood pressure. However, subgroup analysis revealed that controlled-release melatonin significantly reduced nocturnal blood pressure whereas fast-release melatonin had no effect. Systolic blood pressure decreased significantly with controlled-release melatonin (-6.1 mmHg; 95% confidence interval [CI] -10.7 to -1.5; P = 0.009 but not fast-release melatonin (-0.3 mmHg; 95% CI -5.9 to 5.30; P = 0.92. Diastolic blood pressure also decreased significantly with controlled-release melatonin (-3.5 mmHg; 95% CI -6.1 to -0.9; P = 0.009 but not fast-release melatonin (-0.2 mmHg; 95% CI -3.8 to 3.3; P = 0.89. No safety concerns were raised.Conclusion: Add-on controlled-release melatonin to antihypertensive therapy is effective and safe in ameliorating nocturnal hypertension, whereas fast-release melatonin is ineffective. It is necessary

  16. Analysis of skin blood microflow oscillations in patients with rheumatic diseases

    Science.gov (United States)

    Mizeva, Irina; Makovik, Irina; Dunaev, Andrey; Krupatkin, Alexander; Meglinski, Igor

    2017-07-01

    Laser Doppler flowmetry (LDF) has been applied for the assessment of variation in blood microflows in patients with rheumatic diseases and healthy volunteers. Oscillations of peripheral blood microcirculation observed by LDF have been analyzed utilizing a wavelet transform. A higher amplitude of blood microflow oscillations has been observed in a high frequency band (over 0.1 Hz) in patients with rheumatic diseases. Oscillations in the high frequency band decreased in healthy volunteers in response to the cold pressor test, whereas lower frequency pulsations prevailed in patients with rheumatic diseases. A higher perfusion rate at normal conditions was observed in patients, and a weaker response to cold stimulation was observed in healthy volunteers. Analysis of blood microflow oscillations has a high potential for evaluation of mechanisms of blood flow regulation and diagnosis of vascular abnormalities associated with rheumatic diseases.

  17. Gene expression analysis in human breast cancer associated blood vessels.

    Directory of Open Access Journals (Sweden)

    Dylan T Jones

    Full Text Available Angiogenesis is essential for solid tumour growth, whilst the molecular profiles of tumour blood vessels have been reported to be different between cancer types. Although presently available anti-angiogenic strategies are providing some promise for the treatment of some cancers it is perhaps not surprisingly that, none of the anti-angiogenic agents available work on all tumours. Thus, the discovery of novel anti-angiogenic targets, relevant to individual cancer types, is required. Using Affymetrix microarray analysis of laser-captured, CD31-positive blood vessels we have identified 63 genes that are upregulated significantly (5-72 fold in angiogenic blood vessels associated with human invasive ductal carcinoma (IDC of the breast as compared with blood vessels in normal human breast. We tested the angiogenic capacity of a subset of these genes. Genes were selected based on either their known cellular functions, their enriched expression in endothelial cells and/or their sensitivity to anti-VEGF treatment; all features implicating their involvement in angiogenesis. For example, RRM2, a ribonucleotide reductase involved in DNA synthesis, was upregulated 32-fold in IDC-associated blood vessels; ATF1, a nuclear activating transcription factor involved in cellular growth and survival was upregulated 23-fold in IDC-associated blood vessels and HEX-B, a hexosaminidase involved in the breakdown of GM2 gangliosides, was upregulated 8-fold in IDC-associated blood vessels. Furthermore, in silico analysis confirmed that AFT1 and HEX-B also were enriched in endothelial cells when compared with non-endothelial cells. None of these genes have been reported previously to be involved in neovascularisation. However, our data establish that siRNA depletion of Rrm2, Atf1 or Hex-B had significant anti-angiogenic effects in VEGF-stimulated ex vivo mouse aortic ring assays. Overall, our results provide proof-of-principle that our approach can identify a cohort of

  18. Peripheral blood smear image analysis: A comprehensive review

    Directory of Open Access Journals (Sweden)

    Emad A Mohammed

    2014-01-01

    Full Text Available Peripheral blood smear image examination is a part of the routine work of every laboratory. The manual examination of these images is tedious, time-consuming and suffers from interobserver variation. This has motivated researchers to develop different algorithms and methods to automate peripheral blood smear image analysis. Image analysis itself consists of a sequence of steps consisting of image segmentation, features extraction and selection and pattern classification. The image segmentation step addresses the problem of extraction of the object or region of interest from the complicated peripheral blood smear image. Support vector machine (SVM and artificial neural networks (ANNs are two common approaches to image segmentation. Features extraction and selection aims to derive descriptive characteristics of the extracted object, which are similar within the same object class and different between different objects. This will facilitate the last step of the image analysis process: pattern classification. The goal of pattern classification is to assign a class to the selected features from a group of known classes. There are two types of classifier learning algorithms: supervised and unsupervised. Supervised learning algorithms predict the class of the object under test using training data of known classes. The training data have a predefined label for every class and the learning algorithm can utilize this data to predict the class of a test object. Unsupervised learning algorithms use unlabeled training data and divide them into groups using similarity measurements. Unsupervised learning algorithms predict the group to which a new test object belong to, based on the training data without giving an explicit class to that object. ANN, SVM, decision tree and K-nearest neighbor are possible approaches to classification algorithms. Increased discrimination may be obtained by combining several classifiers together.

  19. High-speed video analysis of forward and backward spattered blood droplets

    Science.gov (United States)

    Comiskey, Patrick; Yarin, Alexander; Attinger, Daniel

    2017-11-01

    High-speed videos of blood spatter due to a gunshot taken by the Ames Laboratory Midwest Forensics Resource Center are analyzed. The videos used in this analysis were focused on a variety of targets hit by a bullet which caused either forward, backward, or both types of blood spatter. The analysis process utilized particle image velocimetry and particle analysis software to measure drop velocities as well as the distributions of the number of droplets and their respective side view area. This analysis revealed that forward spatter results in drops travelling twice as fast compared to backward spatter, while both types of spatter contain drops of approximately the same size. Moreover, the close-to-cone domain in which drops are issued is larger in forward spatter than in the backward one. The inclination angle of the bullet as it penetrates the target is seen to play a significant role in the directional preference of the spattered blood. Also, the aerodynamic drop-drop interaction, muzzle gases, bullet impact angle, as well as the aerodynamic wake of the bullet are seen to greatly influence the flight of the drops. The aim of this study is to provide a quantitative basis for current and future research on bloodstain pattern analysis. This work was financially supported by the United States National Institute of Justice (award NIJ 2014-DN-BXK036).

  20. Transcriptome analysis of Neisseria meningitidis in human whole blood and mutagenesis studies identify virulence factors involved in blood survival.

    Directory of Open Access Journals (Sweden)

    Hebert Echenique-Rivera

    2011-05-01

    Full Text Available During infection Neisseria meningitidis (Nm encounters multiple environments within the host, which makes rapid adaptation a crucial factor for meningococcal survival. Despite the importance of invasion into the bloodstream in the meningococcal disease process, little is known about how Nm adapts to permit survival and growth in blood. To address this, we performed a time-course transcriptome analysis using an ex vivo model of human whole blood infection. We observed that Nm alters the expression of ≈30% of ORFs of the genome and major dynamic changes were observed in the expression of transcriptional regulators, transport and binding proteins, energy metabolism, and surface-exposed virulence factors. In particular, we found that the gene encoding the regulator Fur, as well as all genes encoding iron uptake systems, were significantly up-regulated. Analysis of regulated genes encoding for surface-exposed proteins involved in Nm pathogenesis allowed us to better understand mechanisms used to circumvent host defenses. During blood infection, Nm activates genes encoding for the factor H binding proteins, fHbp and NspA, genes encoding for detoxifying enzymes such as SodC, Kat and AniA, as well as several less characterized surface-exposed proteins that might have a role in blood survival. Through mutagenesis studies of a subset of up-regulated genes we were able to identify new proteins important for survival in human blood and also to identify additional roles of previously known virulence factors in aiding survival in blood. Nm mutant strains lacking the genes encoding the hypothetical protein NMB1483 and the surface-exposed proteins NalP, Mip and NspA, the Fur regulator, the transferrin binding protein TbpB, and the L-lactate permease LctP were sensitive to killing by human blood. This increased knowledge of how Nm responds to adaptation in blood could also be helpful to develop diagnostic and therapeutic strategies to control the devastating

  1. Benzodiazepine Consumption Is Associated With Lower Blood Pressure in Ambulatory Blood Pressure Monitoring (ABPM): Retrospective Analysis of 4938 ABPMs.

    Science.gov (United States)

    Mendelson, Nitsan; Gontmacher, Bella; Vodonos, Allina; Novack, Victor; Abu-AjAj, Muhammad; Wolak, Arik; Shalev, Haddar; Wolak, Talya

    2018-03-10

    The effect of chronic benzodiazepine use on blood pressure has not been documented. We aimed to evaluate whether regular benzodiazepine use can be associated to the results of ambulatory blood pressure monitoring (ABPM). A retrospective analysis of the ABPM database between 2009 and 2015 was performed. The study groups were divided according to benzodiazepine treatment at least 3 months before ABPM. Generalized estimating equation (GEE) model analysis was conducted to estimate the association between benzodiazepine treatment and ABPM test measurements. Multivariable COX regression survival analysis model for mortality and cardiovascular (CV) events was performed. A total of 4,938 ABPM studies were included in final analysis, 670 ABPMs of benzodiazepine-treated patients, and 4,268 of untreated patients. The benzodiazepine-treated group was significantly older, with a predominance of female patients, comprised more diabetic patients and consumed more antihypertensive medications. Adjustment for age, gender, diabetes mellitus, and number of antihypertensive medications, showed an association between benzodiazepine treatment and significantly lower ABPM measurements. When the analysis was split into those ≥60 years old and the other ABPM measurements only among ≥60 years old. Multivariable Cox regression survival analysis showed that regular benzodiazepine consumption was not associated with increased mortality or CV events (mean follow-up period of 42.4 ± 19.8 and 42.1 ± 20.0 months, respectively). Long-term use of benzodiazepines by ≥60 years old was independently associated with lower diastolic and systolic blood pressure in all parameters of ABPM, but not among younger patients.

  2. A Meta-Analysis of Blood Glucose Effects on Human Decision Making

    DEFF Research Database (Denmark)

    Orquin, Jacob L.; Kurzban, Robert

    2016-01-01

    The academic and public interest in blood glucose and its relationship to decision making has been increasing over the last decade. To investigate and evaluate competing theories about this relationship, we conducted a psychometric meta-analysis on the effect of blood glucose on decision making. We...... and willingness to work when a situation is food related, but decrease willingness to pay and work in all other situations. Low levels of blood glucose increase the future discount rate for food; that is, decision makers become more impatient, and to a lesser extent increase the future discount rate for money...

  3. Analysis of elements in human blood of patients with chronic kidney disease using neutron activation analysis

    International Nuclear Information System (INIS)

    Metairon, S.; Zamboni, C.B.; Kovacs, L.; Genezini, F.A.; Santos, N.F.; Vilela, E.C.

    2009-01-01

    Neutron activation analysis has been used to determine Br, Ca, Cl, K, Mg and Na concentrations in whole blood of patients with chronic kidney disease (CKD) as well as in whole blood of normal individuals (control group). The dependence of the elements concentration in function of sex, age, time and type of treatment were investigated. The similarities and differences between healthy individuals and CKD are discussed. (author)

  4. RNA/DNA co-analysis from blood stains--Results of a second collaborative EDNAP exercise

    DEFF Research Database (Denmark)

    Haas, C.; Hanson, E.; Anjos, M.J.

    2012-01-01

    A second collaborative exercise on RNA/DNA co-analysis for body fluid identification and STR profiling was organized by the European DNA Profiling Group (EDNAP). Six human blood stains, two blood dilution series (5-0.001 [mu]l blood) and, optionally, bona fide or mock casework samples of human or...

  5. Contributions of social context to blood pressure: findings from a multilevel analysis of social capital and systolic blood pressure.

    Science.gov (United States)

    Hamano, Tsuyoshi; Fujisawa, Yoshikazu; Yamasaki, Masayuki; Ito, Katsuhisa; Nabika, Toru; Shiwaku, Kuninori

    2011-06-01

    In recent years, few studies have quantified the effect of residential context on blood pressure. Although these studies have emphasized the importance of socioeconomic influences such as education or poverty levels, the association between the features of social structure such as social capital and blood pressure remain unclear. Therefore, we investigated whether social capital was associated with systolic blood pressure after controlling for individual potential confounders. We analyzed data from the Shimane Study conducted from 2006 to 2008 in rural mountainous regions of Japan. After excluding the missing data and data of participants taking hypertension medication, we conducted a multilevel analysis of the data for 335 individuals nested within 30 postcode sectors. Systolic blood pressure increased with increasing age and body mass index. We also found that a higher systolic blood pressure was observed among smokers and those taking medication for diabetes. Regarding the contextual effects of social capital, systolic blood pressure increased with an increasing proportion of lack of fairness, after adjustment for individual confounders. To the best of our knowledge, this study is the first to investigate the association between social capital and systolic blood pressure by using a multilevel methodological framework. Surprisingly, we found that lack of fairness had a strong effect on systolic blood pressure. However, we could not find any significant associations between other items of social capital and systolic blood pressure. Further studies are needed to clarify the mechanism by which lack of fairness may have an effect on systolic blood pressure.

  6. Automatic analysis of microscopic images of red blood cell aggregates

    Science.gov (United States)

    Menichini, Pablo A.; Larese, Mónica G.; Riquelme, Bibiana D.

    2015-06-01

    Red blood cell aggregation is one of the most important factors in blood viscosity at stasis or at very low rates of flow. The basic structure of aggregates is a linear array of cell commonly termed as rouleaux. Enhanced or abnormal aggregation is seen in clinical conditions, such as diabetes and hypertension, producing alterations in the microcirculation, some of which can be analyzed through the characterization of aggregated cells. Frequently, image processing and analysis for the characterization of RBC aggregation were done manually or semi-automatically using interactive tools. We propose a system that processes images of RBC aggregation and automatically obtains the characterization and quantification of the different types of RBC aggregates. Present technique could be interesting to perform the adaptation as a routine used in hemorheological and Clinical Biochemistry Laboratories because this automatic method is rapid, efficient and economical, and at the same time independent of the user performing the analysis (repeatability of the analysis).

  7. Emergency medical technician-performed point-of-care blood analysis using the capillary blood obtained from skin puncture.

    Science.gov (United States)

    Kim, Changsun; Kim, Hansol

    2017-12-09

    Comparing a point-of-care (POC) test using the capillary blood obtained from skin puncture with conventional laboratory tests. In this study, which was conducted at the emergency department of a tertiary care hospital in April-July 2017, 232 patients were enrolled, and three types of blood samples (capillary blood from skin puncture, arterial and venous blood from blood vessel puncture) were simultaneously collected. Each blood sample was analyzed using a POC analyzer (epoc® system, USA), an arterial blood gas analyzer (pHOx®Ultra, Nova biomedical, USA) and venous blood analyzers (AU5800, DxH2401, Beckman Coulter, USA). Twelve parameters were compared between the epoc and reference analyzers, with an equivalence test, Bland-Altman plot analysis and linear regression employed to show the agreement or correlation between the two methods. The pH, HCO 3 , Ca 2+ , Na + , K + , Cl - , glucose, Hb and Hct measured by the epoc were equivalent to the reference values (95% confidence interval of mean difference within the range of the agreement target) with clinically inconsequential mean differences and narrow limits of agreement. All of them, except pH, had clinically acceptable agreements between the two methods (results within target value ≥80%). Of the remaining three parameters (pCO 2, pO 2 and lactate), the epoc pCO 2 and lactate values were highly correlated with the reference device values, whereas pO 2 was not. (pCO 2 : R 2 =0.824, y=-1.411+0.877·x; lactate: R 2 =0.902, y=-0.544+0.966·x; pO 2 : R 2 =0.037, y=61.6+0.431·x). Most parameters, except only pO 2 , measured by the epoc were equivalent to or correlated with those from the reference method. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Pleiotropic Analysis of Lung Cancer and Blood Triglycerides.

    Science.gov (United States)

    Zuber, Verena; Marconett, Crystal N; Shi, Jianxin; Hua, Xing; Wheeler, William; Yang, Chenchen; Song, Lei; Dale, Anders M; Laplana, Marina; Risch, Angela; Witoelar, Aree; Thompson, Wesley K; Schork, Andrew J; Bettella, Francesco; Wang, Yunpeng; Djurovic, Srdjan; Zhou, Beiyun; Borok, Zea; van der Heijden, Henricus F M; de Graaf, Jacqueline; Swinkels, Dorine; Aben, Katja K; McKay, James; Hung, Rayjean J; Bikeböller, Heike; Stevens, Victoria L; Albanes, Demetrius; Caporaso, Neil E; Han, Younghun; Wei, Yongyue; Panadero, Maria Angeles; Mayordomo, Jose I; Christiani, David C; Kiemeney, Lambertus; Andreassen, Ole A; Houlston, Richard; Amos, Christopher I; Chatterjee, Nilanjan; Laird-Offringa, Ite A; Mills, Ian G; Landi, Maria Teresa

    2016-12-01

    Epidemiologically related traits may share genetic risk factors, and pleiotropic analysis could identify individual loci associated with these traits. Because of their shared epidemiological associations, we conducted pleiotropic analysis of genome-wide association studies of lung cancer (12 160 lung cancer case patients and 16 838 control subjects) and cardiovascular disease risk factors (blood lipids from 188 577 subjects, type 2 diabetes from 148 821 subjects, body mass index from 123 865 subjects, and smoking phenotypes from 74 053 subjects). We found that 6p22.1 (rs6904596, ZNF184) was associated with both lung cancer (P = 5.50x10(-6)) and blood triglycerides (P = 1.39x10(-5)). We replicated the association in 6097 lung cancer case patients and 204 657 control subjects (P = 2.40 × 10(-4)) and in 71 113 subjects with triglycerides data (P = .01). rs6904596 reached genome-wide significance in lung cancer meta-analysis (odds ratio = 1.15, 95% confidence interval = 1.10 to 1.21 ,: Pcombined = 5.20x10(-9)). The large sample size provided by the lipid GWAS data and the shared genetic risk factors between the two traits contributed to the uncovering of a hitherto unidentified genetic locus for lung cancer. Published by Oxford University Press 2016. This work is written by US Government employees and is in the public domain in the United States.

  9. Predicting blood transfusion using automated analysis of pulse oximetry signals and laboratory values.

    Science.gov (United States)

    Shackelford, Stacy; Yang, Shiming; Hu, Peter; Miller, Catriona; Anazodo, Amechi; Galvagno, Samuel; Wang, Yulei; Hartsky, Lauren; Fang, Raymond; Mackenzie, Colin

    2015-10-01

    Identification of hemorrhaging trauma patients and prediction of blood transfusion needs in near real time will expedite care of the critically injured. We hypothesized that automated analysis of pulse oximetry signals in combination with laboratory values and vital signs obtained at the time of triage would predict the need for blood transfusion with accuracy greater than that of triage vital signs or pulse oximetry analysis alone. Continuous pulse oximetry signals were recorded for directly admitted trauma patients with abnormal prehospital shock index (heart rate [HR] / systolic blood pressure) of 0.62 or greater. Predictions of blood transfusion within 24 hours were compared using Delong's method for area under the receiver operating characteristic (AUROC) curves to determine the optimal combination of triage vital signs (prehospital HR + systolic blood pressure), pulse oximetry features (40 waveform features, O2 saturation, HR), and laboratory values (hematocrit, electrolytes, bicarbonate, prothrombin time, international normalization ratio, lactate) in multivariate logistic regression models. We enrolled 1,191 patients; 339 were excluded because of incomplete data; 40 received blood within 3 hours; and 14 received massive transfusion. Triage vital signs predicted need for transfusion within 3 hours (AUROC, 0.59) and massive transfusion (AUROC, 0.70). Pulse oximetry for 15 minutes predicted transfusion more accurately than triage vital signs for both time frames (3-hour AUROC, 0.74; p = 0.004) (massive transfusion AUROC, 0.88; p transfusion prediction (3-hour AUROC, 0.84; p transfusion AUROC, 0.91; p blood transfusion during trauma resuscitation more accurately than triage vital signs or pulse oximetry analysis alone. Results suggest automated calculations from a noninvasive vital sign monitor interfaced with a point-of-care laboratory device may support clinical decisions by recognizing patients with hemorrhage sufficient to need transfusion. Epidemiologic

  10. Analysis of blood transfusion predictors in patients undergoing elective oesophagectomy for cancer

    Directory of Open Access Journals (Sweden)

    Welch Neil T

    2008-01-01

    Full Text Available Abstract Background Oesophagectomy for cancers is a major operation with significant blood loss and usage. Concerns exist about the side effects of blood transfusion, cost and availability of donated blood. We are not aware of any previous study that has evaluated predictive factors for perioperative blood transfusion in patients undergoing elective oesophagectomy for cancer. This study aimed to audit the pattern of blood crossmatch and to evaluate factors predictive of transfusion requirements in oesophagectomy patients. Methods Data was collected from the database of all patients who underwent oesophagectomy for cancer over a 2-year period. Clinico-pathological data collected included patients demographics, clinical factors, tumour histopathological data, preoperative and discharge haemoglobin levels, total blood loss, number of units of blood crossmatched pre-, intra- and postoperatively, number of blood units transfused, crossmatched units reused for another patient and number of blood units wasted. Clinico-pathological variables were evaluated and logistic regression analysis was performed to determine which factors were predictive of blood transfusion. Results A total of 145 patients with a male to female ratio of 2.5:1 and median age of 68 (40–85 years were audited. The mean preoperative haemoglobin (Hb was 13.0 g/dl. 37% of males (Hb 70 years, Hb level Conclusion The cohort of patients audited was over-crossmatched. The identified independent predictors of blood transfusion should be considered in preoperative blood ordering for oesophagectomy patients. This study has directly led to a reduction in the maximum surgical blood-ordering schedule for oesophagectomy to 2 units and a reaudit is underway.

  11. Patient-specific coronary blood supply territories for quantitative perfusion analysis

    Science.gov (United States)

    Zakkaroff, Constantine; Biglands, John D.; Greenwood, John P.; Plein, Sven; Boyle, Roger D.; Radjenovic, Aleksandra; Magee, Derek R.

    2018-01-01

    Abstract Myocardial perfusion imaging, coupled with quantitative perfusion analysis, provides an important diagnostic tool for the identification of ischaemic heart disease caused by coronary stenoses. The accurate mapping between coronary anatomy and under-perfused areas of the myocardium is important for diagnosis and treatment. However, in the absence of the actual coronary anatomy during the reporting of perfusion images, areas of ischaemia are allocated to a coronary territory based on a population-derived 17-segment (American Heart Association) AHA model of coronary blood supply. This work presents a solution for the fusion of 2D Magnetic Resonance (MR) myocardial perfusion images and 3D MR angiography data with the aim to improve the detection of ischaemic heart disease. The key contribution of this work is a novel method for the mediated spatiotemporal registration of perfusion and angiography data and a novel method for the calculation of patient-specific coronary supply territories. The registration method uses 4D cardiac MR cine series spanning the complete cardiac cycle in order to overcome the under-constrained nature of non-rigid slice-to-volume perfusion-to-angiography registration. This is achieved by separating out the deformable registration problem and solving it through phase-to-phase registration of the cine series. The use of patient-specific blood supply territories in quantitative perfusion analysis (instead of the population-based model of coronary blood supply) has the potential of increasing the accuracy of perfusion analysis. Quantitative perfusion analysis diagnostic accuracy evaluation with patient-specific territories against the AHA model demonstrates the value of the mediated spatiotemporal registration in the context of ischaemic heart disease diagnosis. PMID:29392098

  12. Opto-fluidics based microscopy and flow cytometry on a cell phone for blood analysis.

    Science.gov (United States)

    Zhu, Hongying; Ozcan, Aydogan

    2015-01-01

    Blood analysis is one of the most important clinical tests for medical diagnosis. Flow cytometry and optical microscopy are widely used techniques to perform blood analysis and therefore cost-effective translation of these technologies to resource limited settings is critical for various global health as well as telemedicine applications. In this chapter, we review our recent progress on the integration of imaging flow cytometry and fluorescent microscopy on a cell phone using compact, light-weight and cost-effective opto-fluidic attachments integrated onto the camera module of a smartphone. In our cell-phone based opto-fluidic imaging cytometry design, fluorescently labeled cells are delivered into the imaging area using a disposable micro-fluidic chip that is positioned above the existing camera unit of the cell phone. Battery powered light-emitting diodes (LEDs) are butt-coupled to the sides of this micro-fluidic chip without any lenses, which effectively acts as a multimode slab waveguide, where the excitation light is guided to excite the fluorescent targets within the micro-fluidic chip. Since the excitation light propagates perpendicular to the detection path, an inexpensive plastic absorption filter is able to reject most of the scattered light and create a decent dark-field background for fluorescent imaging. With this excitation geometry, the cell-phone camera can record fluorescent movies of the particles/cells as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the solution under test. With a similar opto-fluidic design, we have recently demonstrated imaging and automated counting of stationary blood cells (e.g., labeled white blood cells or unlabeled red blood cells) loaded within a disposable cell counting chamber. We tested the performance of this cell-phone based imaging cytometry and blood analysis platform

  13. Suspected hypoglycaemia in out patient practice: accuracy of dried blood spot analysis.

    Science.gov (United States)

    Parker, D R; Bargiota, A; Cowan, F J; Corrall, R J

    1997-12-01

    The assay of dried blood spots on filter paper to determine blood glucose concentration has been used to detect hypoglycaemia in out patients. We assessed the accuracy of this approach in assaying blood glucose concentrations in the hypoglycaemic range. Volunteers were rendered hypoglycaemic by intravenous infusion of insulin. The glucose concentration in simultaneously taken blood samples was measured either fresh or after drying on filter paper. Twenty-four healthy young volunteers and 9 patients with insulin-dependent diabetes were studied. Plasma glucose concentrations were measured using a standard auto analyser glucose oxidase method. Whole blood taken simultaneously was placed on prepared filter paper and allowed to dry; glucose concentration was then measured using a well-established technique. A correction factor was applied to convert the glucose concentration of plasma to that of whole blood. The relationship between glucose concentrations measured by the two methods was determined by regression coefficient. In the unequivocally hypoglycaemic range (plasma dried blood spot glucose concentrations significantly correlated with standard plasma glucose concentrations (r = 0.81; P dried blood spot method had a sensitivity of 91%. In the range designated probable hypoglycaemia (plasma dried blood spot method was 100% in both ranges. Measurement of glucose concentrations in dried blood spots is specific and sensitive in the hypoglycaemic range. The present study indicates that hypoglycaemia may be excluded or confirmed respectively when levels in excess of 3.7 or below 2.8 mmol/l are found in uncorrected dried blood spot analysis.

  14. Isolation of human genomic DNA for genetic analysis from premature neonates: a comparison between newborn dried blood spots, whole blood and umbilical cord tissue

    Science.gov (United States)

    2013-01-01

    Background Genotyping requires biological sample collection that must be reliable, convenient and acceptable for patients and clinicians. Finding the most optimal procedure of sample collection for premature neonates who have a very limited blood volume is a particular challenge. The aim of the current study was to evaluate the use of umbilical cord (UC) tissue and newborn dried blood spot (DBS)-extracted genomic DNA (gDNA) as an alternative to venous blood-derived gDNA from premature neonates for molecular genetic analysis. All samples were obtained from premature newborn infants between 24-32 weeks of gestation. Paired blood and UC samples were collected from 31 study participants. gDNA was extracted from ethylenediaminetetraacetic acid (EDTA) anticoagulant-treated blood samples (~500 μl) and newborn DBSs (n = 723) using QIAamp DNA Micro kit (Qiagen Ltd., Crawley, UK); and from UC using Qiagen DNAeasy Blood and Tissue kit (Qiagen Ltd., Crawley, UK). gDNA was quantified and purity confirmed by measuring the A260:A280 ratio. PCR amplification and pyrosequencing was carried out to determine suitability of the gDNA for molecular genetic analysis. Minor allele frequency of two unrelated single nucleotide polymorphisms (SNPs) was calculated using the entire cohort. Results Both whole blood samples and UC tissue provided good quality and yield of gDNA, which was considerably less from newborn DBS. The gDNA purity was also reduced after 3 years of storage of the newborn DBS. PCR amplification of three unrelated genes resulted in clear products in all whole blood and UC samples and 86%-100% of newborn DBS. Genotyping using pyrosequencing showed 100% concordance in the paired UC and whole blood samples. Minor allele frequencies of the two SNPs indicated that no maternal gDNA contamination occurred in the genotyping of the UC samples. Conclusions gDNAs from all three sources are suitable for standard PCR and pyrosequencing assays. Given that UC provide good quality

  15. Blood Lead Toxicity Analysis of Multipurpose Canines and Military Working Dogs.

    Science.gov (United States)

    Reid, Paul; George, Clinton; Byrd, Christopher M; Miller, Laura; Lee, Stephen J; Motsinger-Reif, Alison; Breen, Matthew; Hayduk, Daniel W

    Special Operations Forces and their accompanying tactical multipurpose canines (MPCs) who are involved in repeated live-fire exercises and military operations have the potential for increased blood lead levels and toxicity due to aerosolized and environmental lead debris. Clinical lead-toxicity symptoms can mimic other medical disorders, rendering accurate diagnosis more challenging. The objective of this study was to examine baseline lead levels of MPCs exposed to indoor firing ranges compared with those of nontactical military working dogs (MWDs) with limited or no exposure to the same environment. In the second part of the study, results of a commercially available, human-blood lead testing system were compared with those of a benchtop inductively coupled plasma-mass spectrometry (ICP-MS) analysis technique. Blood samples from 18 MPCs were tested during routine clinical blood draws, and six samples from a canine group with limited exposure to environmental lead (nontactical MWDs) were tested for comparison. There was a high correlation between results of the commercial blood-testing system compared with ICP-MS when blood lead levels were higher than 4.0µg/dL. Both testing methods recorded higher blood lead levels in the MPC blood samples than in those of the nontactical MWDs, although none of the MPC samples tested contained lead levels approaching those at which symptoms of lead toxicity have previously been reported in animals (i.e., 35µg/dL). 2018.

  16. Analysis of Cyanide in Blood by Headspace-Isotope-Dilution-GC-MS

    DEFF Research Database (Denmark)

    Løbger, Lise Lotte; Petersen, Henning Willads; Andersen, Jens Enevold Thaulov

    2008-01-01

    An uncomplicated, rapid, automated procedure for the analysis of low cyanide concentrations in whole blood is reported. The analysis was performed by headspace gas chromatography and mass spectrometry in the (1H12C14N) and m/z 29 (1H13C15N). Carryover from cyanide adsorption onto the surface...

  17. PIXE analysis of chinese chicken-blood stone

    International Nuclear Information System (INIS)

    Lin, E.K.; Wang, C.W.; Yu, Y.C.; Liu, T.Y.; Cheng, H.S.; Zhu, H.X.; Yang, H.J.

    1999-01-01

    This paper reports the chemical compositions of chicken-blood stone Ji Xue Shi measured by Proton Induced X-ray Emission (PIXE). The experimental result show that for the red portion of chicken-blood stone, the concentration of Hg is as high as 20 wt%, and the concentration of S can be above 10 wt%. For the non-red portion the main chemical compositions are Al 2 O 3 and SiO 2 . The obtained chemical compositions are close to those of kaolinite for Balin chicken-blood stone, and of pyrophyllite for Changhua chicken-blood stone, respectively. So far many Changhua chicken-blood stones and Balin chicken-blood stones were found in China, the PIXE method can be used to explore the provenance of available chicken-blood stones. (author)

  18. Laboratory Workflow Analysis of Culture of Periprosthetic Tissues in Blood Culture Bottles.

    Science.gov (United States)

    Peel, Trisha N; Sedarski, John A; Dylla, Brenda L; Shannon, Samantha K; Amirahmadi, Fazlollaah; Hughes, John G; Cheng, Allen C; Patel, Robin

    2017-09-01

    Culture of periprosthetic tissue specimens in blood culture bottles is more sensitive than conventional techniques, but the impact on laboratory workflow has yet to be addressed. Herein, we examined the impact of culture of periprosthetic tissues in blood culture bottles on laboratory workflow and cost. The workflow was process mapped, decision tree models were constructed using probabilities of positive and negative cultures drawn from our published study (T. N. Peel, B. L. Dylla, J. G. Hughes, D. T. Lynch, K. E. Greenwood-Quaintance, A. C. Cheng, J. N. Mandrekar, and R. Patel, mBio 7:e01776-15, 2016, https://doi.org/10.1128/mBio.01776-15), and the processing times and resource costs from the laboratory staff time viewpoint were used to compare periprosthetic tissues culture processes using conventional techniques with culture in blood culture bottles. Sensitivity analysis was performed using various rates of positive cultures. Annualized labor savings were estimated based on salary costs from the U.S. Labor Bureau for Laboratory staff. The model demonstrated a 60.1% reduction in mean total staff time with the adoption of tissue inoculation into blood culture bottles compared to conventional techniques (mean ± standard deviation, 30.7 ± 27.6 versus 77.0 ± 35.3 h per month, respectively; P < 0.001). The estimated annualized labor cost savings of culture using blood culture bottles was $10,876.83 (±$337.16). Sensitivity analysis was performed using various rates of culture positivity (5 to 50%). Culture in blood culture bottles was cost-effective, based on the estimated labor cost savings of $2,132.71 for each percent increase in test accuracy. In conclusion, culture of periprosthetic tissue in blood culture bottles is not only more accurate than but is also cost-saving compared to conventional culture methods. Copyright © 2017 American Society for Microbiology.

  19. Analysis of Ca and Mg in blood of golden hamster using NAA technique

    International Nuclear Information System (INIS)

    Aguiar, Rodrigo O.; Zamboni, Cibele B.; Medeiros, Jose A.G.

    2009-01-01

    Neutron activation analysis (NAA) technique has been used to determine simultaneously Ca and Mg concentrations in whole blood of Golden Hamster. The reference values for Ca (0.17 - 0.29 gL -1 ) and Mg (0.042 - 0.074 gL -1 ) can be used to performed biochemistry investigation using whole blood. (author)

  20. Analysis of Ca and Mg in blood of golden hamster using NAA technique

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, Rodrigo O.; Zamboni, Cibele B.; Medeiros, Jose A.G. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil)], e-mail: rodrigoaguiar@usp.br, e-mail: czamboni@ipen.br, e-mail: jageiros@yahoo.com.br

    2009-07-01

    Neutron activation analysis (NAA) technique has been used to determine simultaneously Ca and Mg concentrations in whole blood of Golden Hamster. The reference values for Ca (0.17 - 0.29 gL{sup -1} ) and Mg (0.042 - 0.074 gL{sup -1} ) can be used to performed biochemistry investigation using whole blood. (author)

  1. Blood pressure-lowering effect of Shinrin-yoku (Forest bathing): a systematic review and meta-analysis.

    Science.gov (United States)

    Ideno, Yuki; Hayashi, Kunihiko; Abe, Yukina; Ueda, Kayo; Iso, Hiroyasu; Noda, Mitsuhiko; Lee, Jung-Su; Suzuki, Shosuke

    2017-08-16

    Shinrin-yoku (experiencing the forest atmosphere or forest bathing) has received increasing attention from the perspective of preventive medicine in recent years. Some studies have reported that the forest environment decreases blood pressure. However, little is known about the possibility of anti-hypertensive applications of Shinrin-yoku. This study aimed to evaluate preventive or therapeutic effects of the forest environment on blood pressure. We systematically reviewed the medical literature and performed a meta-analysis.Four electronic databases were systematically searched for the period before May 2016 with language restriction of English and Japanese. The review considered all published, randomized, controlled trials, cohort studies, and comparative studies that evaluated the effects of the forest environment on changes in systolic blood pressure. A subsequent meta-analysis was performed. Twenty trials involving 732 participants were reviewed. Systolic blood pressure of the forest environment was significantly lower than that of the non-forest environment. Additionally, diastolic blood pressure of the forest environment was significantly lower than that of the non-forest environment. This systematic review shows a significant effect of Shinrin-yoku on reduction of blood pressure.

  2. [Analysis for Discordance of Positive and Negative Blood Typing by Gel Card].

    Science.gov (United States)

    Li, Cui-Ying; Xu, Hong; Lei, Hui-Fen; Liu, Juan; Li, Xiao-Wei

    2017-08-01

    To explore the method of Gel card identifying ABO blood group, determine the inconsistent cause and the distribution of disease affecting factors, and put forward a method of its solutions. To collect 240 positive and negative typing-discordant blood speciments from patients examined by Gel card and send these speciments to blood type reference laboratory for examining with the classic tube method and serological test, such as salivary blood-group substance, in order to performe genotyping method when serologic test can not be determined. Among 240 positive and negative typing-discordant blood speciments from patients examined by Gel card, 107 blood speciments were positive and negative consistent examined by false agglutination test (44.58%), 133 blood specinents were discordent examined by false agglutination (55.42%), out of them, 35 cases (14.58%) with inconsistent cold agglutination test, 22 cases (9.17%) with weakened AB antigenicity, 16 cases (6.67%) with ABO subtyping, 12 cases (5.00%) with positive direct antiglobulin test, 11 cases (4.58%) with reduced or without antibodies, 11 cases (4.58%) with false aggregation caused by drugs or protein, 11 cases (4.58%) with salivary blood-type substances, 8 cases (3.33%) with non-ABO alloantibody, and 7 cases (2.92%) with allogeneic bone marrow transplantation. The distribution of disease were following: blood disease (16.83%), tumor (11.88%), and cardiopulmonary diseases (11.39%); chi-square test results indicated that the distribution significantly different. The analysis of ABO blood grouping shows a variety factors influencing positive and negative blood typing, and the Gel Card identification can produc more false positive blood types. Therefore, more attention should be paid on the high incidence diseases, such as blood disease, tumor, and cardiopulmonary disease.

  3. Blood, urine, and hair kinetic analysis following an acute lead intoxication.

    Science.gov (United States)

    Ho, G; Keutgens, A; Schoofs, R; Kotolenko, S; Denooz, R; Charlier, C

    2011-01-01

    A case of lead exposure resulting from the accidental ingestion of a lead-containing solution is reported. Because of clinical management rapidly performed through chelation therapy by 2,3-dimercaptopropane sulfonate sodium and meso-2,3-dimercaptosuccinic acid, blood lead levels of this 51-year-old patient were moderate (412.9 μg/L) and no clinical symptoms were observed. Numerous blood and urine samples were collected for kinetic analysis of lead elimination. However, we report the first case in which hair samples were analyzed to determine the excretion level of lead after acute intoxication.

  4. Blood elements concentration in cyclists investigated by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Zamboni, C.B.; Kovacs, L.; Metairon, S.; Azevedo, M.R.A.; Furholz, C.F.; Uchida, M.C.

    2016-01-01

    In this study Br, Ca, Cl, Fe, K, Mg, Na, S and Zn levels in blood samples of cyclists were investigated using neutron activation analysis technique. The results were compared to individuals of the same age and gender, but not involved with physical activities (control group), which showed considerable differences. A decrease mainly in Br (91 %) and Ca (78 %) and an increase in Fe (26 %), S (82 %) and Zn (22 %) levels were evidenced. These results emphasize the importance of blood monitoring for the maintenance of endurance athletes performance, particularly for Br, Ca and S. (author)

  5. ABO blood group and esophageal carcinoma risk: from a case-control study in Chinese population to meta-analysis.

    Science.gov (United States)

    Wang, Wei; Liu, Lei; Wang, Zhiwei; Lu, Xiaopeng; Wei, Min; Lin, Tianlong; Zhang, Yixin; Jiang, Songqi; Wang, Qiang; Cao, Ziang; Shi, Minxin

    2014-10-01

    The association between ABO blood group and the risk of esophageal carcinoma (EC) in previously published studies is uncertain and conflicting. The aim of the current study was to determine the correlation of ABO blood group with EC risk via a case-control study and meta-analysis. We performed a population-based case-control study of 3,595 cases and 41,788 controls in Chinese population to evaluate the association between ABO blood group and EC risk. Then, a comprehensive meta-analysis combining our original data and previously published data was conducted to clearly discern the real relationship. The strength of association was measured by odds ratios (ORs) with 95% confidence intervals (CI). In our case-control study, the risk of EC in blood group B was significantly higher than that in non-B groups (A, O, and AB) (OR = 1.15, 95% CI 1.09-1.21). Compared with non-O groups (A, B, and AB), individuals with blood group O demonstrated a reduced risk of EC (OR = 0.90, 95% CI 0.85-0.94). The meta-analysis also indicated that blood group B was associated with significantly higher EC risk (OR = 1.20, 95% CI 1.10-1.31), and people with blood group O had a decreased EC risk (OR = 0.94, 95% CI 0.90-0.99). Neither the case-control study nor the meta-analysis produced any significant association of blood group A or AB with EC risk. Results from our case-control study and the followed meta-analysis confirmed that there was an increased risk of EC in blood group B individuals, whereas a decreased risk of EC was observed in blood group O individuals.

  6. Reliability on intra-laboratory and inter-laboratory data of hair mineral analysis comparing with blood analysis.

    Science.gov (United States)

    Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol

    2013-02-01

    Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

  7. Whole Blood PCR Amplification with Pfu DNA Polymerase and Its Application in Single-Nucleotide Polymorphism Analysis.

    Science.gov (United States)

    Liu, Er-Ping; Wang, Yan; He, Xiao-Hui; Guan, Jun-Jie; Wang, Jin; Qin, Zheng-Hong; Sun, Wan-Ping

    2015-11-01

    Point-of-care genetic analysis may require polymerase chain reaction (PCR) to be carried out on whole blood. However, human blood contains natural inhibitors of PCR such as hemoglobin, immunoglobulin G, lactoferrin, and proteases, as well as anticoagulant agents, including EDTA and heparin that can reduce whole blood PCR efficiency. Our purpose was to develop a highly specific, direct whole blood single-nucleotide polymorphism (SNP) analysis method based on allele-specific (AS) PCR that is mediated by Pfu DNA polymerase and phosphorothioate-modified AS primers. At high Mg(2+) concentrations, Pfu DNA polymerase efficiently amplified genomic DNA in a reaction solution containing up to 14% whole blood. Among the three anticoagulants tested, Pfu DNA polymerase showed the highest activity with sodium citrate. Meanwhile, Triton X-100 and betaine inhibited Pfu DNA polymerase activity in whole blood PCR, whereas trehalose had virtually no effect. These findings provided for the development of a low-cost, simple, and fast direct whole blood genotyping method that uses Pfu DNA polymerase combined with phosphorothioate AS primers for CYP2C9*3 and VKORC1(-1639) loci. With its high DNA amplification efficiency and tolerance of various blood conditions, Pfu DNA polymerase can be used in clinical laboratories to analyze SNPs in whole blood samples.

  8. Life course path analysis of birth weight, childhood growth, and adult systolic blood pressure

    DEFF Research Database (Denmark)

    Gamborg, Michael; Andersen, Per Kragh; Baker, Jennifer L

    2009-01-01

    body size, and thereby the total effect, of size and changes in size on later outcomes. Using data on childhood body size and adult systolic blood pressure from a sample of 1,284 Danish men born between 1936 and 1970, the authors compared results from path analysis with results from 3 standard...... regression methods. Path analysis produced easily interpretable results, and compared with standard regression methods it produced a noteworthy gain in statistical power. The effect of change in relative body size on adult blood pressure was more pronounced after age 11 years than in earlier childhood....... These results suggest that increases in body size prior to age 11 years are less harmful to adult blood pressure than increases occurring after this age....

  9. In vivo flow cytometry for blood cell analysis using differential epi-detection of forward scattered light

    Science.gov (United States)

    Paudel, Hari P.; Jung, Yookyung; Raphael, Anthony; Alt, Clemens; Wu, Juwell; Runnels, Judith; Lin, Charles P.

    2018-02-01

    The present standard of blood cell analysis is an invasive procedure requiring the extraction of patient's blood, followed by ex-vivo analysis using a flow cytometer or a hemocytometer. We are developing a noninvasive optical technique that alleviates the need for blood extraction. For in-vivo blood analysis we need a high speed, high resolution and high contrast label-free imaging technique. In this proceeding report, we reported a label-free method based on differential epi-detection of forward scattered light, a method inspired by Jerome Mertz's oblique back-illumination microscopy (OBM) (Ford et al, Nat. Meth. 9(12) 2012). The differential epi-detection of forward light gives phase contrast image at diffraction-limited resolution. Unlike reflection confocal microscopy (RCM), which detects only sharp refractive index variation and suffers from speckle noise, this technique is suitable for detection of subtle variation of refractive index in biological tissue and it provides the shape and the size of cells. A custom built high speed electronic detection circuit board produces a real-time differential signal which yields image contrast based on phase gradient in the sample. We recorded blood flow in-vivo at 17.2k lines per second in line scan mode, or 30 frames per second (full frame), or 120 frame per second (quarter frame) in frame scan mode. The image contrast and speed of line scan data recording show the potential of the system for noninvasive blood cell analysis.

  10. Tracking flow of leukocytes in blood for drug analysis

    Science.gov (United States)

    Basharat, Arslan; Turner, Wesley; Stephens, Gillian; Badillo, Benjamin; Lumpkin, Rick; Andre, Patrick; Perera, Amitha

    2011-03-01

    Modern microscopy techniques allow imaging of circulating blood components under vascular flow conditions. The resulting video sequences provide unique insights into the behavior of blood cells within the vasculature and can be used as a method to monitor and quantitate the recruitment of inflammatory cells at sites of vascular injury/ inflammation and potentially serve as a pharmacodynamic biomarker, helping screen new therapies and individualize dose and combinations of drugs. However, manual analysis of these video sequences is intractable, requiring hours per 400 second video clip. In this paper, we present an automated technique to analyze the behavior and recruitment of human leukocytes in whole blood under physiological conditions of shear through a simple multi-channel fluorescence microscope in real-time. This technique detects and tracks the recruitment of leukocytes to a bioactive surface coated on a flow chamber. Rolling cells (cells which partially bind to the bioactive matrix) are detected counted, and have their velocity measured and graphed. The challenges here include: high cell density, appearance similarity, and low (1Hz) frame rate. Our approach performs frame differencing based motion segmentation, track initialization and online tracking of individual leukocytes.

  11. Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses.

    Science.gov (United States)

    Jousi, Milla; Saikko, Simo; Nurmi, Jouni

    2017-09-11

    Point-of-care (POC) testing is highly useful when treating critically ill patients. In case of difficult vascular access, the intraosseous (IO) route is commonly used, and blood is aspirated to confirm the correct position of the IO-needle. Thus, IO blood samples could be easily accessed for POC analyses in emergency situations. The aim of this study was to determine whether IO values agree sufficiently with arterial values to be used for clinical decision making. Two samples of IO blood were drawn from 31 healthy volunteers and compared with arterial samples. The samples were analysed for sodium, potassium, ionized calcium, glucose, haemoglobin, haematocrit, pH, blood gases, base excess, bicarbonate, and lactate using the i-STAT® POC device. Agreement and reliability were estimated by using the Bland-Altman method and intraclass correlation coefficient calculations. Good agreement was evident between the IO and arterial samples for pH, glucose, and lactate. Potassium levels were clearly higher in the IO samples than those from arterial blood. Base excess and bicarbonate were slightly higher, and sodium and ionised calcium values were slightly lower, in the IO samples compared with the arterial values. The blood gases in the IO samples were between arterial and venous values. Haemoglobin and haematocrit showed remarkable variation in agreement. POC diagnostics of IO blood can be a useful tool to guide treatment in critical emergency care. Seeking out the reversible causes of cardiac arrest or assessing the severity of shock are examples of situations in which obtaining vascular access and blood samples can be difficult, though information about the electrolytes, acid-base balance, and lactate could guide clinical decision making. The analysis of IO samples should though be limited to situations in which no other option is available, and the results should be interpreted with caution, because there is not yet enough scientific evidence regarding the agreement of IO

  12. Analysis of the progression of systolic blood pressure using imputation of missing phenotype values

    OpenAIRE

    Vaitsiakhovich, Tatsiana; Drichel, Dmitriy; Angisch, Marina; Becker, Tim; Herold, Christine; Lacour, André

    2014-01-01

    We present a genome-wide association study of a quantitative trait, "progression of systolic blood pressure in time," in which 142 unrelated individuals of the Genetic Analysis Workshop 18 real genotype data were analyzed. Information on systolic blood pressure and other phenotypic covariates was missing at certain time points for a considerable part of the sample. We observed that the dropout process causing missingness is not independent of the initial systolic blood pressure; that is, the ...

  13. [Analysis of Arsenic Compounds in Blood and Urine by HPLC-ICP-MS].

    Science.gov (United States)

    Lin, L; Zhang, S J; Xu, W C; Luo, R X; Ma, D; Shen, M

    2018-02-01

    To establish an analysis method for the detection of 6 arsenic compounds [AsC, AsB, As(Ⅲ), DMA, MMA and As(V)] in blood and urine by high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS), and apply it to real cases. Triton was used to damage cells, and then EDTA·2Na·2H2O was used to complex arsenic compounds in cells, and sonication and protein deposition by acetonitrile were performed for sample pretreatment. With the mobile phase consisted of ammonium carbonate and ultrapure water, gradient elution was performed for obtaining the arsenic compounds in samples, which were analysed by ICP-MS with Hamilton PRP-X100 column. The limits of detection in blood were 1.66-10 ng/mL, while the lower limits of quantitation in blood ranged from 5 to 30 ng/mL. The limits of detection in urine were 0.5-10 ng/mL, while the lower limits of quantitation in urine were 5-30 ng/mL. The relative standard deviation of inter-day and intra-day precisions was less than 10%. This method had been successfully applied to 3 cases. This study has established an analysis method for detecting 6 common arsenic compounds in blood and urine, which can be used to detect the arsenic compounds in the blood and urine from arsenic poisoning cases as well as the patients under arsenic treatment. Copyright© by the Editorial Department of Journal of Forensic Medicine.

  14. Determination of manganese in blood by neutron activation analysis

    International Nuclear Information System (INIS)

    Kocsis, E.; Kovats, M.; Molnar, M.

    1981-01-01

    A new method has been elaborated: the manganese content of a blood sample was precipitated by H 2 O 2 , and analysed by neutron activation analysis. The mean value was 2.67x10 -8 g/g in men, 3.25x10 -8 g/g in women and 3.57x10 -8 g/g in men working as welders for several years. (L.E.)

  15. A meta-analysis of peripheral blood nerve growth factor levels in patients with schizophrenia.

    Science.gov (United States)

    Qin, X-Y; Wu, H-T; Cao, C; Loh, Y P; Cheng, Y

    2017-09-01

    Neurotrophins particularly brain-derived neurotrophic factor (BDNF) and nerve growth factor (NGF) are crucial modulators in the neurodevelopment and maintenance of central and peripheral nervous systems. Neurotrophin hypothesis of schizophrenia (SCZ) postulated that the changes in the brains of SCZ patients are the result of disturbances of developing processes involving neurotrophic factors. This hypothesis was mainly supported by the abnormal regulation of BDNF in SCZ, especially the decreased peripheral blood BDNF levels in SCZ patients validated by several meta-analyses. However, the regulation of NGF in SCZ remains unclear because of the inconsistent findings from the clinical studies. Therefore, we undertook, to the best of our knowledge, the first systematic review with a meta-analysis to quantitatively summarize the peripheral blood NGF data in SCZ patients compared with healthy control (HC) subjects. A systematic search of Pubmed, PsycINFO and Web of Science identified 13 articles encompassing a sample of 1693 individuals for the meta-analysis. Random-effects meta-analysis showed that patients with SCZ had significantly decreased peripheral blood levels of NGF when compared with the HC subjects (Hedges's g=-0.633, 95% confidence interval (CI)=-0.948 to -0.318, Pmeta-regression analyses showed that age, gender and sample size had no moderating effects on the outcome of the meta-analysis, whereas disease severity might be a confounding factor for the meta-analysis. These results demonstrated that patients with SCZ are accompanied by the decreased peripheral blood NGF levels, strengthening the clinical evidence of an abnormal neurotrophin profile in the patients with SCZ.

  16. In vivo analysis of physiological 3D blood flow of cerebral veins

    Energy Technology Data Exchange (ETDEWEB)

    Schuchardt, Florian; Schroeder, Laure; Baeuerle, Jochen; Harloff, Andreas [University Medical Centre, Department of Neurology, Freiburg (Germany); Anastasopoulos, Constantin [University Medical Center, Department of Neuropaediatrics and Muscle Disorders, Freiburg (Germany); University Medical Centre, Department of Neuroradiology, Freiburg (Germany); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine and McCormick School of Engineering, Chicago, IL (United States); Hennemuth, Anja; Drexl, Johann [Fraunhofer MEVIS, Bremen (Germany); Valdueza, Jose M. [Neurological Center, Segeberger Kliniken, Bad Segeberg (Germany); Mader, Irina [University Medical Centre, Department of Neuroradiology, Freiburg (Germany)

    2015-08-15

    To visualize and quantify physiological blood flow of intracranial veins in vivo using time-resolved, 3D phase-contrast MRI (4D flow MRI), and to test measurement accuracy. Fifteen healthy volunteers underwent repeated ECG-triggered 4D flow MRI (3 Tesla, 32-channel head coil). Intracranial venous blood flow was analysed using dedicated software allowing for blood flow visualization and quantification in analysis planes at the superior sagittal, straight, and transverse sinuses. MRI was evaluated for intra- and inter-observer agreement and scan-rescan reproducibility. Measurements of the transverse sinuses were compared with transcranial two-dimensional duplex ultrasound. Visualization of 3D blood flow within cerebral sinuses was feasible in 100 % and within at least one deep cerebral vein in 87 % of the volunteers. Blood flow velocity/volume increased along the superior sagittal sinus and was lower in the left compared to the right transverse sinus. Intra- and inter-observer reliability and reproducibility of blood flow velocity (mean difference 0.01/0.02/0.02 m/s) and volume (mean difference 0.0002/-0.0003/0.00003 l/s) were good to excellent. High/low velocities were more pronounced (8 % overestimation/9 % underestimation) in MRI compared to ultrasound. Four-dimensional flow MRI reliably visualizes and quantifies three-dimensional cerebral venous blood flow in vivo and is promising for studies in patients with sinus thrombosis and related diseases. (orig.)

  17. Blood lead and preeclampsia: A meta-analysis and review of implications.

    Science.gov (United States)

    Poropat, Arthur E; Laidlaw, Mark A S; Lanphear, Bruce; Ball, Andrew; Mielke, Howard W

    2018-01-01

    Multiple cross-sectional studies suggest that there is an association between blood lead and preeclampsia. We performed a systematic review and meta-analysis to summarize information on the association between preeclampsia and lead poisoning. Searches of Medline, Web of Science, Scopus, Pubmed, Science Direct and ProQuest (dissertations and theses) identified 2089 reports, 46 of which were downloaded after reviewing the abstracts, and 11 studies were evaluated as meeting the selection criteria. Evaluation using the ROBINS-I template (Sterne, et al., 2016), indicated moderate risk of bias in all studies. We found that blood lead concentrations were significantly and substantially associated with preeclampsia (k = 12; N = 6069; Cohen's d = 1.26; odds ratio = 9.81; odds ratio LCL = 8.01; odds ratio UCL = 12.02; p = 0.005). Eliminating one study produced a homogeneous meta-analysis and stronger estimates, despite the remaining studies coming from eight separate countries and having countervailing risks of bias. Blood lead concentrations in pregnant women are a major risk factor for preeclampsia, with an increase of 1μg/dL associated with a 1.6% increase in likelihood of preeclampsia, which appears to be the strongest risk factor for preeclampsia yet reported. Pregnant women with historical lead exposure should routinely have blood lead concentrations tested, especially after mid-term. Women with concentrations higher than 5μg/dL should be actively monitored for preeclampsia and be advised to take prophylactic calcium supplementation. All pregnant women should be advised to actively avoid lead exposure. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. [Systematic umbilical cord blood analysis at birth: feasibility and reliability in a French labour ward].

    Science.gov (United States)

    Ernst, D; Clerc, J; Decullier, E; Gavanier, G; Dupuis, O

    2012-10-01

    At birth, evaluation of neonatal well-being is crucial. It is though important to perform umbilical cord blood gas analysis, and then to analyze the samples. We wanted to establish the feasibility and reliability of systematic umbilical cord blood sampling in a French labour ward. Study of systematic umbilical cord blood gas analysis was realized retrospectively from 1000 consecutive deliveries. We first established the feasibility of the samples. Feasibility was defined by the ratio of complete cord acid-base data on the number of deliveries from alive newborns. Afterwards, we established the reliability on the remaining cord samples. Reliability was the ratio of samples that fulfilled quality criteria defined by Westgate et al. and revised by Kro et al., on the number of complete samples from alive newborns. At last, we looked for factors that would influence these results. The systematic umbilical cord blood sample feasibility reached 91.6%, and the reliability reached 80.7%. About the delivery mode, 38.6% of emergency caesarians (IC 95% [30.8-46.3]; Panalysis were significantly less validated during emergency caesarians. Realization of systematic cord blood gas analysis was followed by 8.4% of incomplete samples, and by 19.3% that were uninterpretable. Training sessions should be organized to improve the feasibility and reliability, especially during emergency caesarians. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  19. Simultaneously Measured Interarm Blood Pressure Difference and Stroke: An Individual Participants Data Meta-Analysis.

    Science.gov (United States)

    Tomiyama, Hirofumi; Ohkuma, Toshiaki; Ninomiya, Toshiharu; Mastumoto, Chisa; Kario, Kazuomi; Hoshide, Satoshi; Kita, Yoshikuni; Inoguchi, Toyoshi; Maeda, Yasutaka; Kohara, Katsuhiko; Tabara, Yasuharu; Nakamura, Motoyuki; Ohkubo, Takayoshi; Watada, Hirotaka; Munakata, Masanori; Ohishi, Mitsuru; Ito, Norihisa; Nakamura, Michinari; Shoji, Tetsuo; Vlachopoulos, Charalambos; Yamashina, Akira

    2018-06-01

    We conducted individual participant data meta-analysis to examine the validity of interarm blood pressure difference in simultaneous measurement as a marker to identify subjects with ankle-brachial pressure index blood pressure difference >5 mm Hg as being associated with a significant odds ratio for the presence of ankle-brachial pressure index blood pressure difference >15 mm Hg was associated with a significant Cox stratified adjusted hazard ratio for subsequent stroke (hazard ratio, 2.42; 95% confidence interval, 1.27-4.60; P blood pressure differences, measured simultaneously in both arms, may be associated with vascular damage in the systemic arterial tree. These differences may be useful for identifying subjects with an ankle-brachial pressure index of blood pressure in both arms at the first visit. © 2018 American Heart Association, Inc.

  20. Dried Blood Spot Analysis Suitable for Therapeutic Drug Monitoring of Voriconazole, Fluconazole, and Posaconazole

    Science.gov (United States)

    van der Elst, Kim C. M.; Span, Lambert F. R.; van Hateren, Kai; Vermeulen, Karin M.; van der Werf, Tjip S.; Greijdanus, Ben; Kosterink, Jos G. W.; Uges, Donald R. A.

    2013-01-01

    Invasive aspergillosis and candidemia are important causes of morbidity and mortality in immunocompromised and critically ill patients. The triazoles voriconazole, fluconazole, and posaconazole are widely used for the treatment and prophylaxis of these fungal infections. Due to the variability of the pharmacokinetics of the triazoles among and within individual patients, therapeutic drug monitoring is important for optimizing the efficacy and safety of antifungal treatment. A dried blood spot (DBS) analysis was developed and was clinically validated for voriconazole, fluconazole, and posaconazole in 28 patients. Furthermore, a questionnaire was administered to evaluate the patients' opinions of the sampling method. The DBS analytical method showed linearity over the concentration range measured for all triazoles. Results for accuracy and precision were within accepted ranges; samples were stable at room temperature for at least 12 days; and different hematocrit values and blood spot volumes had no significant influence. The ratio of the drug concentration in DBS samples to that in plasma was 1.0 for voriconazole and fluconazole and 0.9 for posaconazole. Sixty percent of the patients preferred DBS analysis as a sampling method; 15% preferred venous blood sampling; and 25% had no preferred method. There was significantly less perception of pain with the DBS sampling method (P = 0.021). In conclusion, DBS analysis is a reliable alternative to venous blood sampling and can be used for therapeutic drug monitoring of voriconazole, fluconazole, and posaconazole. Patients were satisfied with DBS sampling and had less pain than with venous sampling. Most patients preferred DBS sampling to venous blood sampling. PMID:23896473

  1. An analysis of mobile whole blood collection labor efficiency.

    Science.gov (United States)

    Rose, William N; Dayton, Paula J; Raife, Thomas J

    2011-07-01

    Labor efficiency is desirable in mobile blood collection. There are few published data on labor efficiency. The variability in the labor efficiency of mobile whole blood collections was analyzed. We determined to improve our labor efficiency using lean manufacturing principles. Workflow changes in mobile collections were implemented with the goal of minimizing labor expenditures. To measure success, data on labor efficiency measured by units/hour/full-time equivalent (FTE) were collected. The labor efficiency in a 6-month period before the implementation of changes, and in months 1 to 6 and 7 to 12 after implementation was analyzed and compared. Labor efficiency in the 6-month period preceding implementation was 1.06 ± 0.4 units collected/hour/FTE. In months 1 to 6, labor efficiency declined slightly to 0.92 ± 0.4 units collected/hour/FTE (p = 0.016 vs. preimplementation). In months 7 to 12, the mean labor efficiency returned to preimplementation levels of 1.09 ±0.4 units collected/hour/FTE. Regression analysis correlating labor efficiency with total units collected per drive revealed a strong correlation (R(2) = 0.48 for the aggregate data from all three periods), indicating that nearly half of labor efficiency was associated with drive size. The lean-based changes in workflow were subjectively favored by employees and donors. The labor efficiency of our mobile whole blood drives is strongly influenced by size. Larger drives are more efficient, with diminishing returns above 40 units collected. Lean-based workflow changes were positively received by employees and donors. © 2011 American Association of Blood Banks.

  2. Association Between Blood Glucose and Functional Outcome in Intracerebral Hemorrhage: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Zheng, Jun; Yu, Zhiyuan; Ma, Lu; Guo, Rui; Lin, Sen; You, Chao; Li, Hao

    2018-03-16

    Intracerebral hemorrhage (ICH) is a devastating subtype of stroke. Patients with ICH have poor functional outcomes. The association between blood glucose level and functional outcome in ICH remains unclear. This systematic review and meta-analysis aimed to investigate the association between blood glucose level and functional outcomes in patients with ICH. Literature was searched systemically in PubMed, EMBASE, Web of Science, and Cochrane Library. Published cohort studies evaluating the association between blood glucose and functional outcome in patients with ICH were included. This meta-analysis was performed using odds ratios (ORs) and 95% confidence intervals (CIs). A total of 16 studies were included in our meta-analysis. Our data show that hyperglycemia defined by cutoff values was significantly associated with unfavorable functional outcome (OR, 1.80; 95% CI, 1.36-2.39; P analysis also suggested a significant association between increased blood glucose levels and functional outcomes (OR, 1.05; 95% CI, 1.03-1.07; P functional outcome in ICH. Further studies with larger sample sizes, more time points, and longer follow-up times are necessary to confirm this association. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Global Overexpression of ET-1 Decreases Blood Pressure - A Systematic Review and Meta-Analysis of ET-1 Transgenic Mice.

    Science.gov (United States)

    Lu, Yong Ping; Tsuprykov, Oleg; Vignon-Zellweger, Nicolas; Heiden, Susi; Hocher, Berthold

    2016-01-01

    ET-1 has independent effects on blood pressure regulation in vivo, it is involved in tubular water and salt excretion, promotes constriction of smooth muscle cells, modulates sympathetic nerve activity, and activates the liberation of nitric oxide. To determine the net effect of these partially counteracting mechanisms on blood pressure, a systematic meta-analysis was performed. Based on the principles of Cochrane systematic reviews, we searched in major literature databases - MEDLINE (PubMed), Embase, Google Scholar, and the China Biological Medicine Database (CBM-disc) - for articles relevant to the topic of the blood pressure phenotype of endothelin-1 transgenic (ET-1+/+) mice from January 1, 1988 to March 31, 2016. Review Manager Version 5.0 (Rev-Man 5.0) software was applied for statistical analysis. In total thirteen studies reported blood pressure data. The meta-analysis of blood pressure data showed that homozygous ET-1 transgenic mice (ET-1+/+ mice) had a significantly lower blood pressure as compared to WT mice (mean difference: -2.57 mmHg, 95% CI: -4.98∼ -0.16, P = 0.04), with minimal heterogeneity (P = 0.86). A subgroup analysis of mice older than 6 months revealed that the blood pressure difference between ET-1+/+ mice and WT mice was even more pronounced (mean difference: -6.19 mmHg, 95% CI: -10.76∼ -1.62, P = 0.008), with minimal heterogeneity (P = 0.91). This meta-analysis provides robust evidence that global ET-1 overexpression in mice lowers blood pressure in an age-dependent manner. Older ET-1+/+ mice have a somewhat more pronounced reduction of blood pressure. © 2016 The Author(s) Published by S. Karger AG, Basel.

  4. [Quantitative analysis of blood loss in liposuction].

    Science.gov (United States)

    Schor, N; Zatz, R M; Mendonça, A R; Takatu, P M; Patto, G S

    1989-01-01

    This study was performed in 15 female patients submitted to suction lipectomy as an isolated procedure, to establish blood loss in the procedure. A wide variation of blood-to-fat ratios was observed (17 to 59%) with a mean blood loss in lipoaspirates of 34 +/- 3%. Internal blood losses occurring in the first 72 post-operative hours were as important as or more important than external losses, and responsible for a mean 7% fall in the level of hemoglobin. Internal blood losses occurred between 72 hours and the 7th to the 10th post-operative days and were responsible for a mean 3% fall in the level of hemoglobin. Blood losses occurring in this study were demonstrated to be greater than usually assumed. Some prophylactic measures are recommended to provide for a safer treatment of these patients: an iron supplementation during the pre-operative period; careful clinical and laboratorial screening for bleeding disorders and for the intake of drugs that can interfere with coagulation; use of smaller-diameter cannulas for aspiration, auto-transfusion when aspirating in excess of 1,000 ml, and limiting the aspiration to 1,500 ml.

  5. Study on effect of supplementing iron-fortified food to children athletes by nuclear analysis and blood analysis techniques

    International Nuclear Information System (INIS)

    Qian Qinfang; Sun Jianguo; Feng Weiyue

    1996-01-01

    The iron content in hair and blood for 37 children athletes who were supplemented with 0, 8 and 16 mg Fe/d, respectively, in the form of ferrous gluconate-containing chocolate for 3 months was determined before and after the supplement by INAA, SRXRF and blood analysis. The experimental results indicated that after the supplement of the iron-fortified food, the ferritin level in blood of the male athletes attained to normal and the iron content in hair was increased with the increasing level of supplement, but not in direct proportion. Most of the female athletes had similar results. It is suggested that supplement of 8 mg Fe/d to a child athlete may be adequate

  6. Simplifying sample pretreatment: application of dried blood spot (DBS) method to blood samples, including postmortem, for UHPLC-MS/MS analysis of drugs of abuse.

    Science.gov (United States)

    Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina

    2014-10-01

    The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Direct Trace Element Analysis of Liquid Blood Samples by In-Air Ion Beam Analytical Techniques (PIXE-PIGE).

    Science.gov (United States)

    Huszank, Robert; Csedreki, László; Török, Zsófia

    2017-02-07

    There are various liquid materials whose elemental composition is of interest in various fields of science and technology. In many cases, sample preparation or the extraction can be complicated, or it would destroy the original environment before the analysis (for example, in the case of biological samples). However, multielement direct analysis of liquid samples can be realized by an external PIXE-PIGE measurement system. Particle-induced X-ray and gamma-ray emission spectroscopy (PIXE, PIGE) techniques were applied in external (in-air) microbeam configuration for the trace and main element determination of liquid samples. The direct analysis of standard solutions of several metal salts and human blood samples (whole blood, blood serum, blood plasma, and formed elements) was realized. From the blood samples, Na, P, S, Cl, K, Ca, Fe, Cu, Zn, and Br elemental concentrations were determined. The focused and scanned ion beam creates an opportunity to analyze very small volume samples (∼10 μL). As the sample matrix consists of light elements, the analysis is possible at ppm level. Using this external beam setup, it was found that it is possible to determine elemental composition of small-volume liquid samples routinely, while the liquid samples do not require any preparation processes, and thus, they can be analyzed directly. In the case of lower concentrations, the method is also suitable for the analysis (down to even ∼1 ppm level) but with less accuracy and longer measurement times.

  8. Analysis of baseline, average, and longitudinally measured blood pressure data using linear mixed models.

    Science.gov (United States)

    Hossain, Ahmed; Beyene, Joseph

    2014-01-01

    This article compares baseline, average, and longitudinal data analysis methods for identifying genetic variants in genome-wide association study using the Genetic Analysis Workshop 18 data. We apply methods that include (a) linear mixed models with baseline measures, (b) random intercept linear mixed models with mean measures outcome, and (c) random intercept linear mixed models with longitudinal measurements. In the linear mixed models, covariates are included as fixed effects, whereas relatedness among individuals is incorporated as the variance-covariance structure of the random effect for the individuals. The overall strategy of applying linear mixed models decorrelate the data is based on Aulchenko et al.'s GRAMMAR. By analyzing systolic and diastolic blood pressure, which are used separately as outcomes, we compare the 3 methods in identifying a known genetic variant that is associated with blood pressure from chromosome 3 and simulated phenotype data. We also analyze the real phenotype data to illustrate the methods. We conclude that the linear mixed model with longitudinal measurements of diastolic blood pressure is the most accurate at identifying the known single-nucleotide polymorphism among the methods, but linear mixed models with baseline measures perform best with systolic blood pressure as the outcome.

  9. Determination of mercury in human serum and packed blood cells by neutron activation analysis

    International Nuclear Information System (INIS)

    Versieck, J.; Vanballenberghe, L.; Wittoek, A.; Vermeir, G.; Vandecasteele, C.

    1990-01-01

    A method is described for the determination of mercury in human blood serum and packed blood cells employing neutron activation analysis. Great attention was devoted to the collection and manipulation of the samples. The accuracy and precision of the method were tested by analyzing biological reference materials and by comparing the concentrations measured in a number of serum samples to those obtained by another, independent technique (cold vapor atomic absorption spectrometry) in the same samples. The article reports the levels measured in blood serum and packed blood cells samples from 15 adult volunteers, as well as the figures determined in a open-quotes second-generationclose quotes biological reference material (freeze-dried human serum), prepared and conditioned at the University of Ghent

  10. Energy dispersive X-ray fluorescence spectrometry for the direct multi-element analysis of dried blood spots

    Science.gov (United States)

    Marguí, E.; Queralt, I.; García-Ruiz, E.; García-González, E.; Rello, L.; Resano, M.

    2018-01-01

    Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients. In this sense, dried blood spots (DBS) are proposed as a non-invasive and even self-administered alternative to sampling whole venous blood. This contribution explores the potential of energy dispersive X-ray fluorescence spectrometry for the simultaneous and direct determination of some major (S, Cl, K, Na), minor (P, Fe) and trace (Ca, Cu, Zn) elements in blood, after its deposition onto clinical filter papers, thus giving rise to DBS. For quantification purposes the best strategy was to use matrix-matched blood samples of known analyte concentrations. The accuracy and precision of the method were evaluated by analysis of a blood reference material (Seronorm™ trace elements whole blood L3). Quantitative results were obtained for the determination of P, S, Cl, K and Fe, and limits of detection for these elements were adequate, taking into account their typical concentrations in real blood samples. Determination of Na, Ca, Cu and Zn was hampered by the occurrence of high sample support (Na, Ca) and instrumental blanks (Cu, Zn). Therefore, the quantitative determination of these elements at the levels expected in blood samples was not feasible. The methodology developed was applied to the analysis of several blood samples and the results obtained were compared with those reported by standard techniques. Overall, the performance of the method developed is promising and it could be used to determine the aforementioned elements in blood samples in a simple, fast and economic way. Furthermore, its non-destructive nature enables further analyses by means of complementary techniques to be carried out.

  11. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system.

    Science.gov (United States)

    Cao, Jing; Edwards, Rachel; Chairez, Janette; Devaraj, Sridevi

    2017-12-01

    Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc). Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory) was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics) was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer) for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing.

  12. Retinol analysis in dried blood spots by HPLC.

    Science.gov (United States)

    Craft, N E; Haitema, T; Brindle, L K; Yamini, S; Humphrey, J H; West, K P

    2000-04-01

    There are many advantages to measuring vitamin A in dried blood spots (DBS) from a finger prick as compared to plasma collected by venipuncture. The advantages include easier collection, transport and storage; accessibility to younger and more remote populations; and decreased risk of disease transmission. We describe a method for the extraction of retinol from DBS for analysis by HPLC and initial comparison to plasma retinol. The effects of various buffers, detergents, antioxidants and chelators were evaluated to establish the most effective approach to elute the retinol: retinol binding protein (holo-RBP) complex from the blood collection cards. The process involves ultrasonic agitation to elute holo-RBP into a phosphate buffer containing an antioxidant and metal chelator. The holo-RBP complex was denatured by the addition of ethanol containing additional antioxidants permitting the extraction of free retinol into hexane. Following solvent evaporation, the extract was dissolved in methanol for HPLC analysis. The initial measured retinol levels in freshly collected DBS declined for 6-10 d whether stored at 25, 4 or -20 degrees C, but remained consistent thereafter (homeostatic). By incorporating a "recovery/volume adjustment" factor, measured retinol values in homeostatic DBS were adjusted to the equivalent of plasma retinol. For 17 normal adults, the correlation coefficient was 0.90 between plasma retinol and adjusted DBS retinol in samples that had been stored at -70 degrees C for < 9 mo. The use of this new sample matrix for vitamin A assessment will allow access to previously unavailable populations.

  13. Discrepancy in abo blood grouping

    International Nuclear Information System (INIS)

    Khan, M.N.; Ahmed, Z.; Khan, T.A.

    2013-01-01

    Discrepancies in blood typing is one of the major reasons in eliciting a transfusion reaction. These discrepancies can be avoided through detailed analysis for the blood typing. Here, we report a subgroup of blood group type-B in the ABO system. Donor's blood was analyzed by employing commercial antisera for blood grouping. The results of forward (known antisera) and reverse (known antigen) reaction were not complimentary. A detailed analysis using the standard protocols by American Association of Blood Banking revealed the blood type as a variant of blood group-B instead of blood group-O. This is suggestive of the fact that blood group typing should be performed with extreme care and any divergence, if identified, should be properly resolved to avoid transfusion reactions. Moreover, a major study to determine the blood group variants in Pakistani population is needed. (author)

  14. Analysis of the postoperative status of peripheral blood caused by gastric volvulus of dogs

    OpenAIRE

    VATNIKOV Y.A.; SAHNO N.V.; GOLEVA A.A.

    2016-01-01

    The paper presents analysis of post-operative state of peripheral blood caused by volvulus of the dogs’ stomach. The use of erythrocyte mass in early post-operative period reduces severity of anemia and inflammatory process. The introduction of donor red blood cells reduces severity of action immunosuppressive splenectomy and effects of anesthesia, causing the production of platelets, reticulocytes thus improving reparative processes in the postoperative period.

  15. Plasmodium falciparum HRP2 ELISA for analysis of dried blood spot samples in rural Zambia.

    Science.gov (United States)

    Gibson, Lauren E; Markwalter, Christine F; Kimmel, Danielle W; Mudenda, Lwiindi; Mbambara, Saidon; Thuma, Philip E; Wright, David W

    2017-08-23

    Dried blood spots are commonly used for sample collection in clinical and non-clinical settings. This method is simple, and biomolecules in the samples remain stable for months at room temperature. In the field, blood samples for the study and diagnosis of malaria are often collected on dried blood spot cards, so development of a biomarker extraction and analysis method is needed. A simple extraction procedure for the malarial biomarker Plasmodium falciparum histidine-rich protein 2 (HRP2) from dried blood spots was optimized to achieve maximum extraction efficiency. This method was used to assess the stability of HRP2 in dried blood spots. Furthermore, 328 patient samples made available from rural Zambia were analysed for HRP2 using the developed method. These samples were collected at the initial administration of artemisinin-based combination therapy and at several points following treatment. An average extraction efficiency of 70% HRP2 with a low picomolar detection limit was achieved. In specific storage conditions HRP2 was found to be stable in dried blood spots for at least 6 months. Analysis of patient samples showed the method to have a sensitivity of 94% and a specificity of 89% when compared with microscopy, and trends in HRP2 clearance after treatment were observed. The dried blood spot ELISA for HRP2 was found to be sensitive, specific and accurate. The method was effectively used to assess biomarker clearance characteristics in patient samples, which prove it to be ideal for gaining further insight into the disease and epidemiological applications.

  16. An ARGS-aggrecan assay for analysis in blood and synovial fluid

    DEFF Research Database (Denmark)

    Larsson, S; Lohmander, Stefan; Struglics, A

    2014-01-01

    OBJECTIVE: To validate a modified ligand-binding assay for the detection of aggrecanase generated aggrecan fragments with the ARGS neoepitope in synovial fluid (SF) and blood, and to verify the identity of aggrecan fragments found in blood. DESIGN: An enzyme-linked immunosorbent assay (ELISA....... Aggrecan was purified from serum and plasma pools and analysed by Western blot. RESULTS: The limits of quantification for the ARGS-aggrecan assay was between 0.2 and 0.025 pmol ARGS/ml, and the sensitivity of the assay was improved two-fold compared to when using a standard purified from human donors...... similar, and correlated (r(S) = 0.773, P assay is highly sensitive and suited for analysis...

  17. Meta-analysis of peripheral blood apolipoprotein E levels in Alzheimer's disease.

    Directory of Open Access Journals (Sweden)

    Chong Wang

    Full Text Available BACKGROUND: Peripheral blood Apolipoprotein E (ApoE levels have been proposed as biomarkers of Alzheimer's disease (AD, but previous studies on levels of ApoE in blood remain inconsistent. This meta-analysis was designed to re-examine the potential role of peripheral ApoE in AD diagnosis and its potential value as a candidate biomarker. METHODS: We conducted a systematic literature search of MEDLINE, EMBASE, the Cochrane library, and BIOSIS previews for case-control studies measuring ApoE levels in serum or plasma from AD subjects and healthy controls. The pooled weighted mean difference (WMD and 95% confidence interval (CI were used to estimate the association between ApoE levels and AD risk. RESULTS: Eight studies with a total of 2250 controls and 1498 AD cases were identified and analyzed. The pooled WMD from a random-effect model of AD participants compared with the healthy controls was -5.59 mg/l (95% CI: [-8.12, -3.06]. The overall pattern in WMD was not varied by characteristics of study, including age, country, assay method, publication year, and sample type. CONCLUSIONS: Our meta-analysis supports a lowered level of blood ApoE in AD patients, and indicates its potential value as an important risk factor for AD. Further investigation employing standardized assay for ApoE measurement are still warranted to uncover the precise role of ApoE in the pathophysiology of AD.

  18. Analysis of anaerobic blood cultures in burned patients.

    Science.gov (United States)

    Regules, Jason A; Carlson, Misty D; Wolf, Steven E; Murray, Clinton K

    2007-08-01

    The utility of anaerobic blood culturing is often debated in the general population, but there is limited data on the modern incidence, microbiology, and utility of obtaining routine anaerobic blood cultures for burned patients. We performed a retrospective review of the burned patients electronic medical records database for all blood cultures drawn between January 1997 and September 2005. We assessed blood cultures for positivity, organisms identified, and growth in aerobic or anaerobic media. 85,103 blood culture sets were drawn, with 4059 sets from burned patients. Three hundred and forty-five single species events (619 total blood culture isolates) were noted in 240 burned patients. For burned patients, four isolates were obligate anaerobic bacteria (all Propionibacterium acnes). Anaerobic versus aerobic culture growth was recorded in 310 of 619 (50.1%) burned patient blood culture sets. 46 (13.5%) of the identified organisms, most of which were not obligate anaerobic bacteria, were identified from solely anaerobic media. The results of our study suggest that the detection of significant anaerobic bacteremia in burned patients is very rare and that anaerobic bottles are not needed in this population for that indication. However anaerobic blood cultures systems are also able to detect facultative and obligate aerobic bacteria; therefore, the deletion of the anaerobic culture medium may have deleterious clinical impact.

  19. Silica Coated Paper Substrate for Paper-Spray Analysis of Therapeutic Drugs in Dried Blood Spots

    Science.gov (United States)

    Zhang, Zhiping; Xu, Wei; Manicke, Nicholas E.; Cooks, R. Graham; Ouyang, Zheng

    2011-01-01

    Paper spray is a newly developed ambient ionization method that has been applied for direct qualitative and quantitative analysis of biological samples. The properties of the paper substrate and spray solution have a significant impact on the release of chemical compounds from complex sample matrices, the diffusion of the analytes through the substrate, and the formation of ions for mass spectrometry analysis. In this study, a commercially available silica-coated paper was explored in an attempt to improve the analysis of therapeutic drugs in dried blood spots (DBS). The dichloromethane/isopropanol solvent has been identified as an optimal spray solvent for the analysis. The comparison was made with paper spray using chromatography paper as substrate with methanol/water as solvent for the analysis of verapamil, citalopram, amitriptyline, lidocaine and sunitinib in dried blood spots. It has been demonstrated the efficiency of recovery of the analytes was notably improved with the silica coated paper and the limit of quantitation (LOQ) for the drug analysis was 0.1 ng mL−1 using a commercial triple quadrupole mass spectrometer. The use of silica paper substrate also resulted in a sensitivity improvement of 5-50 fold in comparison with chromatography papers, including the Whatmann ET31 paper used for blood card. Analysis using a handheld miniature mass spectrometer Mini 11 gave LOQs of 10~20 ng mL−1 for the tested drugs, which is sufficient to cover the therapeutic ranges of these drugs. PMID:22145627

  20. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system

    Directory of Open Access Journals (Sweden)

    Jing Cao

    2017-12-01

    Full Text Available Background: Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc. Methods: Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Results: Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Conclusion: Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. Impact of the study: This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing. Keywords: Epoc, Capillary, Transport, Blood gas, Point of care

  1. Meta-analysis identifies common and rare variants influencing blood pressure and overlapping with metabolic trait loci

    NARCIS (Netherlands)

    Liu, C. (Chunyu); A. Kraja (Aldi); J.A. Smith (Jennifer A); J. Brody (Jennifer); N. Franceschini (Nora); J.C. Bis (Joshua); K.M. Rice (Kenneth); A.C. Morrison (Alanna); Y. Lu (Yingchang); Weiss, S. (Stefan); X. Guo (Xiuqing); W. Palmas (Walter); L.W. Martin (Lisa); Y.D. Chen (Y.); Surendran, P. (Praveen); F. Drenos (Fotios); Cook, J.P. (James P.); P. Auer (Paul); A.Y. Chu (Audrey); Giri, A. (Ayush); Zhao, W. (Wei); M. Jakobsdottir (Margret); Lin, L.-A. (Li-An); J.M. Stafford (Jeanette M.); N. Amin (Najaf); Mei, H. (Hao); J. Yao (Jiefen); J.M. Voorman (Jeanine); M.G. Larson (Martin); M.L. Grove (Megan); A.V. Smith (Albert Vernon); S.J. Hwang; H. Chen (Han); T. Huan (Tianxiao); Kosova, G. (Gulum); N.O. Stitziel (Nathan); S. Kathiresan (Sekar); N.J. Samani (Nilesh); H. Schunkert (Heribert); P. Deloukas (Panagiotis); M. Li (Man); C. Fuchsberger (Christian); C. Pattaro (Cristian); M. Gorski (Mathias); C. Kooperberg (Charles); G. Papanicolaou (George); Rossouw, J.E. (Jacques E.); J.D. Faul (Jessica D.); S.L.R. Kardia (Sharon); C. Bouchard (Claude); L.J. Raffel (Leslie); Uitterlinden, A.G. (André G.); O.H. Franco (Oscar); R. Vasan (Ramachandran); C.J. O'Donnell (Christopher); K.D. Taylor (Kent); K.Y. Liu; E.P. Bottinger (Erwin); R.F. Gottesman (Rebecca); E.W. Daw (E. Warwick); F. Giulianini (Franco); S.K. Ganesh (Santhi); E. Salfati (Elias); T.B. Harris (Tamara); Launer, L.J. (Lenore J.); M. Dörr (Marcus); S.B. Felix (Stephan); R. Rettig (Rainer); H. Völzke (Henry); E. Kim (Eric); W.-J. Lee (Wen-Jane); I.T. Lee; Sheu, W.H.-H. (Wayne H.-H.); Tsosie, K.S. (Krystal S.); Edwards, D.R.V. (Digna R. Velez); Y. Liu (YongMei); Correa, A. (Adolfo); D.R. Weir (David); U. Völker (Uwe); P.M. Ridker (Paul); E.A. Boerwinkle (Eric); V. Gudnason (Vilmundur); A. Reiner (Alexander); Van Duijn, C.M. (Cornelia M.); I.B. Borecki (Ingrid); T.L. Edwards (Todd L.); A. Chakravarti (Aravinda); Rotter, J.I. (Jerome I.); B.M. Psaty (Bruce); R.J.F. Loos (Ruth); M. Fornage (Myriam); G.B. Ehret (Georg); C. Newton-Cheh (Christopher); D. Levy (Daniel); D.I. Chasman (Daniel)

    2016-01-01

    textabstractMeta-analyses of association results for blood pressure using exome-centric single-variant and gene-based tests identified 31 new loci in a discovery stage among 146,562 individuals, with follow-up and meta-analysis in 180,726 additional individuals (total n = 327,288). These blood

  2. Spatio-temporal analysis of blood perfusion by imaging photoplethysmography

    Science.gov (United States)

    Zaunseder, Sebastian; Trumpp, Alexander; Ernst, Hannes; Förster, Michael; Malberg, Hagen

    2018-02-01

    Imaging photoplethysmography (iPPG) has attracted much attention over the last years. The vast majority of works focuses on methods to reliably extract the heart rate from videos. Only a few works addressed iPPGs ability to exploit spatio-temporal perfusion pattern to derive further diagnostic statements. This work directs at the spatio-temporal analysis of blood perfusion from videos. We present a novel algorithm that bases on the two-dimensional representation of the blood pulsation (perfusion map). The basic idea behind the proposed algorithm consists of a pairwise estimation of time delays between photoplethysmographic signals of spatially separated regions. The probabilistic approach yields a parameter denoted as perfusion speed. We compare the perfusion speed versus two parameters, which assess the strength of blood pulsation (perfusion strength and signal to noise ratio). Preliminary results using video data with different physiological stimuli (cold pressure test, cold face test) show that all measures are influenced by those stimuli (some of them with statistical certainty). The perfusion speed turned out to be more sensitive than the other measures in some cases. However, our results also show that the intraindividual stability and interindividual comparability of all used measures remain critical points. This work proves the general feasibility of employing the perfusion speed as novel iPPG quantity. Future studies will address open points like the handling of ballistocardiographic effects and will try to deepen the understanding of the predominant physiological mechanisms and their relation to the algorithmic performance.

  3. DNA and RNA analysis of blood and muscle from bodies with variable postmortem intervals

    DEFF Research Database (Denmark)

    Hansen, Jakob; Lesnikova, Iana; Funder, Anette Mariane Daa

    2014-01-01

    The breakdown of DNA and RNA in decomposing human tissue represents a major obstacle for postmortem forensic molecular analysis. This study investigated the feasibility of performing PCR-based molecular analysis of blood and muscle tissue from 45 autopsy cases with defined postmortem intervals...... for postmortem forensic molecular analysis as well as for retrospective research projects based on archived FFPE specimens....

  4. Cytogenetic analysis of peripheral blood lymphocytes after arteriography (exposure to x-rays and contrast medium)

    International Nuclear Information System (INIS)

    Popova, L.; Hadjidekova, V.; Karadjov, G.; Agova, S.; Traskov, D.; Hadjidekov, V.

    2005-01-01

    Backgrounds. The purpose of our study is to investigate the cytogenetic analysis findings in peripheral blood lymphocytes of 29 patients who had undergone diagnostic radiography. Methods. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13-68 years). Cytogenetic analyses of peripheral lymphocytes were performed before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03-0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency were used as biomarkers of genotoxicity. Results. The estimated frequency of chromosomal aberrations and micronuclei in the peripheral blood lymphocytes of patients after arteriography examination was significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations was nearly double after examination and proved to be constant in the analysis after 24 hours. Conclusions. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase in cytogenetic damage in peripheral blood lymphocytes. (author)

  5. Cytogenetic analysis in peripheral blood lymphocytes after arteriography (exposure to X-rays and contrast medium)

    International Nuclear Information System (INIS)

    Hadjidekova, V.; Popova, L.; Hristova, R.; Hadjidekov, V.

    2006-01-01

    Full text: The purpose of our study is to investigate the cytogenetic effects in peripheral blood lymphocytes of 29 patients who had undergone diagnostic angiography. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13 and 68 years). Cytogenetic analysis was performed in peripheral lymphocytes before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03 - 0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency was used as biomarkers of genotoxicity. The estimated frequency of chromosomal aberrations and micronuclei in peripheral blood lymphocytes of patients after arteriography examination is significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations nearly double after examination and remained constant at 24h analysis. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase of the cytogenetic injury in peripheral blood lymphocytes

  6. Osteopontin (OPN) as a CSF and blood biomarker for multiple sclerosis: A systematic review and meta-analysis.

    Science.gov (United States)

    Agah, Elmira; Zardoui, Arshia; Saghazadeh, Amene; Ahmadi, Mona; Tafakhori, Abbas; Rezaei, Nima

    2018-01-01

    Identifying a reliable biomarker may accelerate diagnosis of multiple sclerosis (MS) and lead to early management of the disease. Accumulating evidence suggest that cerebrospinal fluid (CSF) and peripheral blood concentration of osteopontin (OPN) may have diagnostic and prognostic value in MS. We conducted a systematic review and meta-analysis of studies that measured peripheral blood and CSF levels of OPN in MS patients and controls to evaluate the diagnostic potential of this biomarker better. We searched PubMed, Web of Science and Scopus databases to find articles that measured OPN concentration in peripheral blood and CSF samples from MS patients up to October 19, 2016. Q statistic tests and the I2 index were applied for heterogeneity assessment. If the I2 index was less than 40%, the fixed-effects model was used for meta-analysis. Random-effects meta-analysis was chosen if the I2 value was greater than 40%. After removal of duplicates, 918 articles were identified, and 27 of them fulfilled the inclusion criteria. We included 22 eligible studies in the final meta-analysis. MS patients, in general, had considerably higher levels of OPN in their CSF and blood when compared to all types of controls (pCSF of MS subgroups (pCSF concentrations of OPN between MS patient subtypes. CIS patients had significantly lower levels of OPN both in their peripheral blood and CSF compared to patients with progressive subtypes of MS (pCSF concentration of OPN was significantly higher among RRMS patients compared to the CIS patients and SPMS patients (PCSF compared to patients with stable disease (P = 0.007). The result of this study confirms that increased levels of OPN exist in CSF and peripheral blood of MS patients and strengthens the evidence regarding the clinical utility of OPN as a promising and validated biomarker for MS.

  7. Rapid analysis of malathion in blood using head space-solid phase microextraction and selected ion monitoring.

    Science.gov (United States)

    Namera, A; Yashiki, M; Nagasawa, N; Iwasaki, Y; Kojima, T

    1997-08-04

    A simple and rapid method for analysis of malathion in blood was developed using head space-solid phase microextraction (HS-SPME) and gas chromatography mass spectrometry/ electron impact ionization-selected ion monitoring (GC-MS/EI-SIM). A vial containing a blood sample, ammonium sulphate, sulphuric acid and fenitrothion as an internal standard, was heated at 90 degrees C for 15 min. The extraction fiber of the SPME was exposed for 5 min in the head space of the vial. The compounds absorbed on the fiber were detached by exposing the fibre in the injection port of GC-MS. A straight calibration curve was obtained between malathion concentrations of 2.5 to 50.0 micrograms g-1 in blood. No interfering substances were found, and the time for analysis was 40 min for one sample.

  8. Effects of Vegetarian Diets on Blood Lipids: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Wang, Fenglei; Zheng, Jusheng; Yang, Bo; Jiang, Jiajing; Fu, Yuanqing; Li, Duo

    2015-10-27

    Vegetarian diets exclude all animal flesh and are being widely adopted by an increasing number of people; however, effects on blood lipid concentrations remain unclear. This meta-analysis aimed to quantitatively assess the overall effects of vegetarian diets on blood lipids. We searched PubMed, Scopus, Embase, ISI Web of Knowledge, and the Cochrane Library through March 2015. Studies were included if they described the effectiveness of vegetarian diets on blood lipids (total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, and triglyceride). Weighted mean effect sizes were calculated for net changes by using a random-effects model. We performed subgroup and univariate meta-regression analyses to explore sources of heterogeneity. Eleven trials were included in the meta-analysis. Vegetarian diets significantly lowered blood concentrations of total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, and non-high-density lipoprotein cholesterol, and the pooled estimated changes were -0.36 mmol/L (95% CI -0.55 to -0.17; PVegetarian diets did not significantly affect blood triglyceride concentrations, with a pooled estimated mean difference of 0.04 mmol/L (95% CI -0.05 to 0.13; P=0.40). This systematic review and meta-analysis provides evidence that vegetarian diets effectively lower blood concentrations of total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, and non-high-density lipoprotein cholesterol. Such diets could be a useful nonpharmaceutical means of managing dyslipidemia, especially hypercholesterolemia. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  9. Gram-negative and -positive bacteria differentiation in blood culture samples by headspace volatile compound analysis.

    Science.gov (United States)

    Dolch, Michael E; Janitza, Silke; Boulesteix, Anne-Laure; Graßmann-Lichtenauer, Carola; Praun, Siegfried; Denzer, Wolfgang; Schelling, Gustav; Schubert, Sören

    2016-12-01

    Identification of microorganisms in positive blood cultures still relies on standard techniques such as Gram staining followed by culturing with definite microorganism identification. Alternatively, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or the analysis of headspace volatile compound (VC) composition produced by cultures can help to differentiate between microorganisms under experimental conditions. This study assessed the efficacy of volatile compound based microorganism differentiation into Gram-negatives and -positives in unselected positive blood culture samples from patients. Headspace gas samples of positive blood culture samples were transferred to sterilized, sealed, and evacuated 20 ml glass vials and stored at -30 °C until batch analysis. Headspace gas VC content analysis was carried out via an auto sampler connected to an ion-molecule reaction mass spectrometer (IMR-MS). Measurements covered a mass range from 16 to 135 u including CO2, H2, N2, and O2. Prediction rules for microorganism identification based on VC composition were derived using a training data set and evaluated using a validation data set within a random split validation procedure. One-hundred-fifty-two aerobic samples growing 27 Gram-negatives, 106 Gram-positives, and 19 fungi and 130 anaerobic samples growing 37 Gram-negatives, 91 Gram-positives, and two fungi were analysed. In anaerobic samples, ten discriminators were identified by the random forest method allowing for bacteria differentiation into Gram-negative and -positive (error rate: 16.7 % in validation data set). For aerobic samples the error rate was not better than random. In anaerobic blood culture samples of patients IMR-MS based headspace VC composition analysis facilitates bacteria differentiation into Gram-negative and -positive.

  10. Analysis of photogem (hematoporphyrin derivative) and blood interaction

    Science.gov (United States)

    Corrêa, Thaila Quatrini; Pratavieira, Sebastião.; Bagnato, Vanderlei Salvador

    2017-07-01

    Sepsis is a potentially fatal condition that occurs when an infectious agent, such as bacteria, gets in a person's bloodstream. The infection affects the immune system, which then triggers a reaction that can cause uncontrolled inflammation in the body1 . All blood components may present the contamination. Once inoculated bacteria in a blood component, it can proliferate rapidly reaching high levels within few hours and, in a short period, it may lead to several basal changes in the individual and even death2 . Studies have shown an increase in the incidence of sepsis over the years, and it is mainly due to the growing resistance of microorganisms to antibiotics since these drugs are still sold and used improperly3 . The photodynamic inactivation (PDI) has been one of the most promising alternatives for microbiological control and other diseases. Its principle of action is based on a photosensitizer (PS) activated by light at the correct wavelength to oxidize organic substrates, resulting in cytotoxic effects4,5. The technique is being applied to a large variety of microorganisms and decontaminating blood. Some studies have investigated the action of PDI in blood6-9, and even then, there is a need to understand better what happens when we apply PS and light in blood in an attempt to eliminate the microorganisms. Photogem is a hematoporphyrin derivative that has been used with success in many clinical cases such as skin cancer and inactivation of bacteria10,11. Previous studies have shown that PDI using Photogem as a photosensitizing molecule is a good alternative for blood decontamination12,13. In the previous studies were observed hemolysis when red blood cells (RBCs) were submitted to PS concentration and light dose tested. This study has been conducted to further understand through absorption spectroscopy and fluorescence confocal microscope the PS-blood interaction. This is important because the PDI damage needs to be restricted to the bacteria and the blood

  11. Effects of garlic on blood pressure in patients with and without systolic hypertension: a meta-analysis.

    Science.gov (United States)

    Reinhart, Kurt M; Coleman, Craig I; Teevan, Colleen; Vachhani, Payal; White, C Michael

    2008-12-01

    Garlic has been suggested to lower blood pressure; however, studies evaluating this parameter have provided conflicting results. To examine the effect of garlic on blood pressure in patients with and without elevated systolic blood pressure (SPB) through meta-analyses of randomized controlled trials. A systematic search of MEDLINE, CINAHL, and the Cochrane Central Register of Controlled Trials was conducted to identify randomized controlled trials in humans evaluating garlic's effect on blood pressure. All databases were searched from their inception through June 26, 2008, using the key words garlic, Allium sativum, and allicin. A manual search of published literature was used to identify additional relevant studies. To be included in the analysis, studies must have been written in English or German and reported endpoints of SBP or diastolic blood pressure (DBP). Studies whose population had a mean baseline SBP greater than 140 mm Hg were evaluated separately from those whose population had lower baseline blood pressures. Garlic's effect on SBP and DBP was treated as a continuous variable and weighted mean differences were calculated using a random-effects model. Ten trials were included in the analysis; 3 of these had patients with elevated SBP. Garlic reduced SBP by 16.3 mm Hg (95% CI 6.2 to 26.5) and DBP by 9.3 mm Hg (95% CI 5.3 to 13.3) compared with placebo in patients with elevated SBP. However, the use of garlic did not reduce SBP or DBP in patients without elevated SBP. There was only a minor degree of heterogeneity in the analyses and publication bias did not appear to influence the results. This meta-analysis suggests that garlic is associated with blood pressure reductions in patients with an elevated SBP although not in those without elevated SBP. Future research should focus on the impact of garlic on clinical events and the assessment of the long-term risk of harm.

  12. Laser speckle imaging of rat retinal blood flow with hybrid temporal and spatial analysis method

    Science.gov (United States)

    Cheng, Haiying; Yan, Yumei; Duong, Timothy Q.

    2009-02-01

    Noninvasive monitoring of blood flow in retinal circulation will reveal the progression and treatment of ocular disorders, such as diabetic retinopathy, age-related macular degeneration and glaucoma. A non-invasive and direct BF measurement technique with high spatial-temporal resolution is needed for retinal imaging. Laser speckle imaging (LSI) is such a method. Currently, there are two analysis methods for LSI: spatial statistics LSI (SS-LSI) and temporal statistical LSI (TS-LSI). Comparing these two analysis methods, SS-LSI has higher signal to noise ratio (SNR) and TSLSI is less susceptible to artifacts from stationary speckle. We proposed a hybrid temporal and spatial analysis method (HTS-LSI) to measure the retinal blood flow. Gas challenge experiment was performed and images were analyzed by HTS-LSI. Results showed that HTS-LSI can not only remove the stationary speckle but also increase the SNR. Under 100% O2, retinal BF decreased by 20-30%. This was consistent with the results observed with laser Doppler technique. As retinal blood flow is a critical physiological parameter and its perturbation has been implicated in the early stages of many retinal diseases, HTS-LSI will be an efficient method in early detection of retina diseases.

  13. Erythrocyte 2,3-diphosphoglycerate depletion associated with hypophosphatemia detected by routine arterial blood gas analysis.

    Science.gov (United States)

    Larsen, V H; Waldau, T; Gravesen, H; Siggaard-Andersen, O

    1996-01-01

    To describe a clinical case where an extremely low erythrocyte 2,3-diphosphoglycerate concentration (2,3-DPG) was discovered by routine blood gas analysis supplemented by computer calculation of derived quantities. The finding of a low 2,3-DPG revealed a severe hypophosphatemia. Open uncontrolled study of a patient case. Intensive care observation during 41 days. A 44 year old woman with an abdominal abscess. Surgical drainage, antibiotics and parenteral nutrition. daily routine blood gas analyses with computer calculation of the hemoglobin oxygen affinity and estimation of the 2,3-DPG. An abrupt decline of 2,3-DPG was observed late in the course coincident with a pronounced hypophosphatemia. The fall in 2,3-DPG was verified by enzymatic analysis. 2,3-DPG may be estimated by computer calculation of routine blood gas data. A low 2,3-DPG which may be associated with hypophosphatemia causes an unfavorable increase in hemoglobin oxygen affinity which reduces the oxygen release to the tissues.

  14. Microchip analysis of lithium in blood using moving boundary electrophoresis and zone electrophoresis

    NARCIS (Netherlands)

    Vrouwe, E.X.; Lüttge, Regina; Olthuis, Wouter; van den Berg, Albert

    The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration

  15. Microchip analysis of lithium in blood using moving boundary electrophoresis and zone electrophoresis

    NARCIS (Netherlands)

    Vrouwe, E.X.; Luttge, R.; Olthuis, W.; Berg, van den A.

    2005-01-01

    The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration

  16. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    International Nuclear Information System (INIS)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon

    2002-01-01

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  17. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2002-09-15

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  18. Risk of transmission of Creutzfeldt-Jakob disease via blood and blood products. The French risk-analysis over the last 15 years.

    Science.gov (United States)

    Martin, M; Trouvin, J-H

    2013-09-01

    Risk of transmission of Creutzfeldt-Jakob disease (infectious agent, responsible of spongiform encephalopathy) via blood and blood components (including the plasma-derived medicinal products such as coagulation factors and immunoglobulins) have been a subject of concern for Health authorities since the early 1980s, with a regain of interest in the 1990s, with the bovine spongiform encephalopathy outbreak followed few years after with the notification of the first cases of variant Creutzfeldt-Jakob disease in humans. The risk-analysis and measures taken by the French authorities in the period 1990-2010 will be described with the various assumptions and working hypothesis used and revisited as new findings become available. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  19. Analysis of the stability of urea in dried blood spots collected and stored on filter paper.

    Science.gov (United States)

    Quraishi, Rizwana; Lakshmy, Ramakrishnan; Mukhopadhyay, Ashok Kumar; Jailkhani, Bansi Lal

    2013-05-01

    The ability to use dry blood spots (DBSs) on filter paper for the analysis of urea levels could be an important diagnostic tool for areas that have limited access to laboratory facilities. We developed a method for the extraction and quantification of urea from DBSs that were stored on 3M Whatman filter paper and investigated the effect of long-term storage on the level of urea in DBSs. DBSs of 4.5 mm in diameter were used for our assay, and we determined the urea levels in blood using a commercially available enzymatic kit (UV GLDH-method; Randox laboratories Ltd., UK). The DBSs on filter discs were stored at 4℃ or at 37℃ for 120 days. The mean intra- and inter-assay coefficient of variance for our method of urea extraction from dried blood was 4.2% and 6.3%, respectively. We collected 75 fresh blood samples and compared the urea content of each fresh sample with the urea content of DBSs taken from corresponding fresh blood samples. Regression analysis reported a regression coefficient (r) value of 0.97 and a recovery of urea from dried spots was 102.2%. Urea concentrations in DBSs were stable for up to 120 and 90 days when stored at 4℃ and 37℃, respectively. Our results show that urea can be stored and quantitatively recovered from small volumes of blood that was collected on filter paper.

  20. Analysis of inventory strategies for blood components in a regional blood center using process simulation.

    Science.gov (United States)

    Baesler, Felipe; Nemeth, Matías; Martínez, Cristina; Bastías, Alfonso

    2014-02-01

    The storage of blood components is an important concern in the blood supply chain. Because these are perishable products, the definition of good inventory policies is crucial to reduce shortages and spills. To analyze and propose inventory policies in a regional blood center, a discrete event simulation model was created using simulation software (Arena 12.0, Rockwell Software). The model replicates the activities that are performed along the supply chain including donation arrivals, testing, production, inventory management, and dispatching. Twelve different scenarios were analyzed, with each one representing different inventory policies composed of a combination of an optimal inventory, a reorder point, and a level of extra donations. The best scenario demonstrates that it is possible to decrease unsatisfied demand and wastage of red blood cell units by 2.5 and 3%, respectively, when compared to current practices. This study shows that simulation is an alternative that can be used to model inventory components in blood centers. A responsible selection of inventory variables can improve the capability of the system to respond to the final patient requirements. © 2013 American Association of Blood Banks.

  1. Qualitative analysis fingertip patterns in ABO blood group

    OpenAIRE

    S. V. KShirsagar

    2013-01-01

    The inheritance of the dermatoglyphic patterns is polygenic. The genetic basis of the blood group is well established. The correlation between the dermatoglyphic patterns and the ABO blood group is studied by some workers in different populations. In the present study, the correlation between dermatoglyphics and ABO blood group is studied in the Marathwada Region of Maharashtra. The qualitative data included fingertip patterns and three indices. It was observed that, the Arch pattern is more ...

  2. Blood cholesterol and vascular mortality by age, sex, and blood pressure: a meta-analysis of individual data from 61 prospective studies with 55,000 vascular deaths

    DEFF Research Database (Denmark)

    NN, NN; Jensen, Gorm Boje

    2007-01-01

    BACKGROUND: Age, sex, and blood pressure could modify the associations of total cholesterol (and its main two fractions, HDL and LDL cholesterol) with vascular mortality. This meta-analysis combined prospective studies of vascular mortality that recorded both blood pressure and total cholesterol...... pressures, is unexplained, and invites further research. Nevertheless, there is conclusive evidence from randomised trials that statins substantially reduce not only coronary event rates but also total stroke rates in patients with a wide range of ages and blood pressures....... and blood pressure. During nearly 12 million person years at risk between the ages of 40 and 89 years, there were more than 55,000 vascular deaths (34,000 ischaemic heart disease [IHD], 12,000 stroke, 10,000 other). Information about HDL cholesterol was available for 150,000 participants, among whom...

  3. Advantages and Challenges of Dried Blood Spot Analysis by Mass Spectrometry Across the Total Testing Process

    Science.gov (United States)

    Zakaria, Rosita; Allen, Katrina J.; Koplin, Jennifer J.; Roche, Peter

    2016-01-01

    Introduction Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. Methods To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; “blood spot” and “mass spectrometry”; while excluding “newborn”; and “neonate”. In addition, databases were restricted to English language and human specific. There was no time period limit applied. Results As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. Conclusions DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required. PMID:28149263

  4. Comparative analysis of autologous blood transfusion and allogeneic blood transfusion in surgical patients

    OpenAIRE

    Long, Miao-Yun; Liu, Zhong-Han; Zhu, Jian-Guang

    2014-01-01

    Objective: To investigate application effects of autologous blood transfusion and allogeneic blood transfusion in surgically treated patients receiving spine surgery, abdomen surgery and ectopic pregnancy surgery. Methods: 130 patients who would undergo selective operations were divided into autologous transfusion group and allogeneic transfusion group. Both groups received the same anesthesia, and there was no significant difference in transfusion volume or fluid infusion volume. Results: Th...

  5. Study on the effect of supplementation of ironfortified food to chinese juvenile athletes by nuclear analysis techniques and blood analysis

    International Nuclear Information System (INIS)

    Qian, Q.F.; Feng, W.Y.; Zhang, P.Q.; Chai, C.F.; Pan, J.X.; Wu, Y.Y.; Chao, Z.Y.

    1996-01-01

    The iron contents in the hair and blood samples of 37 juvenile athletes who were supplemented with 0, 8 and 16 mg Fe/day, respectively, in the food of ferrous gluconatecontaining chocolate for 3 months were determined before and after the supplementation by INAA, SRXRF and blood analysis. The experimental results showed that after supplementation of the iron-fortified food, the normal ferritin level in the blood of the male athletes was attained and the iron content in the hair was increased with supplementation, but both are not in the positive proportion. Most of the female athletes had similar results. It is suggested that supplementation of 8 mg iron/day to juvenile athletes may be desirable. (author). 3 refs., 4 figs., 1 tab

  6. Garlic intake lowers fasting blood glucose: meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Hou, Li-qiong; Liu, Yun-hui; Zhang, Yi-yi

    2015-01-01

    Garlic is a common spicy flavouring agent also used for certain therapeutic purposes. Garlic's effects on blood glucose have been the subject of many clinical and animal studies, however, studies reporting hypoglycemic effects of garlic in humans are conflicting. A comprehensive literature search was conducted to identify relevant trials of garlic or garlic extracts on markers of glycemic control [fasting blood glucose (FBG), postprandial glucose (PPG), glycosylated haemoglobin (HbA1c)]. A meta-analysis of the effect of garlic intake on human was done to assess garlic's effectiveness in lowering glucose levels. Two reviewers extracted data from each of the identified studies. Seven eligible randomized controlled trials with 513 subjects were identified. Pooled analyses showed that garlic intake results in a statistically significant lowering in FBG [SMD=-1.67; 95% CI (-2.80, -0.55), p=0.004]. Our pooled analyses did not include PPG control and HbA1c outcomes. Because only 1 study included in the meta-analysis reported PPG variables and only 2 studies reported HbA1c variables. In conclusion, the current meta-analysis showed that the administration of garlic resulted in a significant reduction in FBG concentrations. More trials are needed to investigate the effectiveness of garlic on HbA1c and PPG.

  7. Does whole blood coagulation analysis reflect developmental haemostasis?

    DEFF Research Database (Denmark)

    Ravn, Hanne Berg; Andreasen, Jo Bønding; Hvas, Anne-Mette

    2017-01-01

    .05), but there was no sign of developmental changes in whole blood coagulation assessment when applying ROTEM, apart from clotting time in the EXTEM assay (P reach statistical significance. Citrate-anticoagulated blood showed...

  8. Application of the adaptive wavelet transform for analysis of blood flow oscillations in the human skin

    International Nuclear Information System (INIS)

    Tankanag, Arina; Chemeris, Nikolay

    2008-01-01

    An original method for the analysis of oscillations of cutaneous blood flow has been developed, which makes use of laser Doppler flowmetry (LDF) data and is based on the continuous wavelet transform and adaptive wavelet theory. The potential of the method has been demonstrated in experiments with the response of microcirculatory bed to the local linearly-increasing heating of a skin spot. The use of adaptive wavelet transform for analysis of peripheral blood flow oscillations enables one to process short (5 min) LDF signals in a wide frequency range (0.009-2 Hz). The major advantage of the method proposed, as compared to traditional wavelet analysis, has been shown to be a significant reduction of 'border effects'. This makes possible a correct low-frequency component analysis of much shorter LDF signals compared to those used in traditional wavelet processing.

  9. Quantification of surgical blood loss.

    Science.gov (United States)

    Lee, Marcel H; Ingvertsen, Britt T; Kirpensteijn, Jolle; Jensen, Asger L; Kristensen, Annemarie T

    2006-06-01

    To compare gravimetric and colorimetric methods of quantifying surgical blood loss, and to determine if there is a correlation between preoperative hemostatic tests (buccal mucosa bleeding time [BMBT] and intraoperative blood loss). Prospective clinical study. Dogs (n=15) admitted for cutaneous tumor excision, orthopedic procedure, or exploratory laparotomy. Intraoperative blood loss was quantified by measuring irrigation fluid and weighing surgical sponges used for blood and fluid collection during surgery. Results of gravimetric measurements were then correlated to blood loss quantified using spectrophotometric analysis of hemoglobin (Hb) content. Hemostatic variables including BMBT were measured before surgery and compared with the calculated amount of blood loss. Blood loss quantified by gravimetric measurement showed a significant correlation with colorimetric determination of Hb content in surgical sponges and collected irrigation fluid (r=0.93, P<.0001). BMBT correlated weakly but significantly with intraoperative blood loss (r=0.56, P<.05). Quantifying intraoperative blood loss using spectrophotometric Hb analysis accurately assessed the amount of blood loss; however, it is a time-consuming procedure, primarily applicable as a research tool. Gravimetric evaluation of intraoperative blood loss was found to be an accurate method, which can be recommended for use in a clinical setting. Estimation of blood loss using a gravimetric method is accurate and applicable in the clinical setting and provides surgeons with a simple and objective tool to evaluate intraoperative blood loss.

  10. Application of a stereoscopic digital subtraction angiography approach to blood flow analysis

    International Nuclear Information System (INIS)

    Fencil, L.E.; Doi, K.; Hoffmann, K.R.

    1986-01-01

    The authors are developing a stereoscopic digital subtraction angiographic (DSA) approach for accurate measurement of the size, magnification factor, orientation, and blood flow of a selected vessel segment. We employ a Siemens Digitron 2 and a Stereolix x-ray tube with a 25-mm tube shift. Absolute vessel sizes in each stereoscopic image are determined using the magnification factor and an iterative deconvolution technique employing the LSF of the DSA system. From data on vessel diameter and three-dimensional orientation, the effective attenuation coefficient of the diluted contrast medium can be determined, thus allowing accurate blood flow analysis in high-frame-rate DSA images. The accuracy and precision of the approach will be studied using both static and dynamic phantoms

  11. Temporal distribution of blood donations in three Brazilian blood centers and its repercussion on the blood supply.

    Science.gov (United States)

    Oliveira, Claudia Di Lorenzo; de Almeida-Neto, Cesar; Liu, Emily Jing; Sabino, Ester Cerdeira; Leão, Silvana Carneiro; Loureiro, Paula; Wright, David; Custer, Brian; Gonçalez, Thelma Therezinha; Capuani, Ligia; Busch, Michael; Proietti, Anna Bárbara de Freitas Carneiro

    2013-01-01

    Seasonal distribution of blood donation hinders efforts to provide a safe and adequate blood supply leading to chronic and persistent shortages. This study examined whether holidays, geographical area and donation type (community versus replacement) has any impact on the fluctuation of donations. The numbers of blood donations from 2007 through 2010 in three Brazilian Retrovirus Epidemiological Donor Study II (REDS-II) participating centers were analyzed according to the week of donation. The weeks were classified as holiday or non-holiday. To compare donations performed during holiday versus non-holiday weeks, tabulations and descriptive statistics for weekly donations by blood center were examined and time series analysis was conducted. The average weekly number of donations varied according to the blood center and type of week. The average number of donations decreased significantly during Carnival and Christmas and increased during the Brazilian National Donor Week. The fluctuation was more pronounced in Recife and Belo Horizonte when compared to São Paulo and higher among community donors. National bank holidays affect the blood supply by reducing available blood donations. Blood banks should take into account these oscillations in order to plan local campaigns, aiming at maintaining the blood supply at acceptable levels.

  12. Portable real time analysis system for regional cerebral blood flow

    International Nuclear Information System (INIS)

    Tiernan, T.; Entine, G.; Stump, D.A.; Prough, D.S.

    1988-01-01

    A very portable, regional cerebral blood flow (rCBF) analysis instrument system suitable for use in the operating theater during surgery is under development. Cadmium telluride (CdTe) solid state radiation detectors, an 8086 based data acquisition and communications module and a DEC Microvax computer are used so that the instrument is very compact, yet has the computational power to provide real time data analysis in the clinical environment. The instrument is currently being used at Bowman Gray School of Medicine to study rCBF during cardiopulmonary bypass surgery (CPB). Preliminary studies indicate that monitoring rCBF during this surgical procedure may provide insights into the mechanism that causes a significant fraction of these patients to suffer post operative neuropsychological deficit

  13. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    Science.gov (United States)

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1988-01-01

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.

  14. Improving left ventricular segmentation in four-dimensional flow MRI using intramodality image registration for cardiac blood flow analysis.

    Science.gov (United States)

    Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino

    2018-01-01

    Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P  0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Smartphone-based assessment of blood alteration severity

    Science.gov (United States)

    Li, Xianglin; Xue, Jiaxin; Li, Wei; Li, Ting

    2018-02-01

    Blood quality and safety management is a critical issue for cold chain transportation of blood or blood-based biological reagent. The conventional methods of blood alteration severity assessment mainly rely on kit test or blood-gas analysis required opening the blood package to get samples, which cause possible blood pollution and are complicate, timeconsuming, and expensive. Here we proposed to develop a portable, real-time, safety, easy-operated and low cost method aimed at assessing blood alteration severity. Color images of the blood in transparent blood bags were collected with a smartphone and the alteration severity of the blood was assessed by the smartphone app offered analysis of RGB color values of the blood. The algorithm is based on a large number sample of RGB values of blood at different alteration degree. The blood quality results evaluated by the smartphone are in accordance with the actual data. This study indicates the potential of smart phone in real time, convenient, and reliable blood quality assessment.

  16. Blood donors and factors impacting the blood donation decision: motives for donating blood in Turkish sample.

    Science.gov (United States)

    Karacan, Eda; Cengiz Seval, Guldane; Aktan, Zeynep; Ayli, Meltem; Palabiyikoglu, Refia

    2013-12-01

    Donations in Turkey are insufficient to cover the high transfusion needs arising from large numbers of thalassemia and sickle cell anemia patients and increasing demands for blood due to advanced surgery and cancer treatment. The most acceptable means to get blood is voluntary blood donation and the blood donor system in Turkey mostly depends on a combination of voluntary and involuntary donors. The main aim of this study is to explore the motivations of Turkish voluntary blood donors toward blood donation and to determine predictors of blood donation motivation. A cross-sectional sample survey of active blood donors in Ankara, Turkey was conducted. The sample consisted of 189 male volunteer blood donor adults. Donors filled in a self-administered questionnaire including the measures of demographic information, empathetic concern, altruism, social responsibility and blood donation motivation questionnaire during donation. Factor analysis of Blood Donation Motivation Measure with varimax rotation revealed a three-factor solution named as "values and moral duty", "positive feelings and esteem" and "self-benefit and external reasons". The results with regression analyses showed that only social responsibility had an significant effect independent of age, income, and education on blood donation motivation. These result reflects that blood donation motivation not only linked to a high degree of altruistic reasons, but also to a combination of some self-regarding motives. Additionally, feelings of empathy or altruism may be less strong at the time the decision to help, other factors may have a larger influence on helping decisions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Local cooling reduces skin ischemia under surface pressure in rats: an assessment by wavelet analysis of laser Doppler blood flow oscillations

    International Nuclear Information System (INIS)

    Jan, Yih-Kuen; Liao, Fuyuan; Lee, Bernard; Foreman, Robert D

    2012-01-01

    The objectives of this study were to investigate the effects of local cooling on skin blood flow response to prolonged surface pressure and to identify associated physiological controls mediating these responses using the wavelet analysis of blood flow oscillations in rats. Twelve Sprague–Dawley rats were randomly assigned to three protocols, including pressure with local cooling (Δt = −10 °C), pressure with local heating (Δt = 10 °C) and pressure without temperature changes. Pressure of 700 mmHg was applied to the right trochanter area of rats for 3 h. Skin blood flow was measured using laser Doppler flowmetry. The 3 h loading period was divided into non-overlapping 30 min epochs for the analysis of the changes of skin blood flow oscillations using wavelet spectral analysis. The wavelet amplitudes and powers of three frequencies (metabolic, neurogenic and myogenic) of skin blood flow oscillations were calculated. The results showed that after an initial loading period of 30 min, skin blood flow continually decreased under the conditions of pressure with heating and of pressure without temperature changes, but maintained stable under the condition of pressure with cooling. Wavelet analysis revealed that stable skin blood flow under pressure with cooling was attributed to changes in the metabolic and myogenic frequencies. This study demonstrates that local cooling may be useful for reducing ischemia of weight-bearing soft tissues that prevents pressure ulcers. (paper)

  18. Blood flow analysis with considering nanofluid effects in vertical channel

    Science.gov (United States)

    Noreen, S.; Rashidi, M. M.; Qasim, M.

    2017-06-01

    Manipulation of heat convection of copper particles in blood has been considered peristaltically. Two-phase flow model is used in a channel with insulating walls. Flow analysis has been approved by assuming small Reynold number and infinite length of wave. Coupled equations are solved. Numerical solution are computed for the pressure gradient, axial velocity function and temperature. Influence of attention-grabbing parameters on flow entities has been analyzed. This study can be considered as mathematical representation to the vibrance of physiological systems/tissues/organs provided with medicine.

  19. Blood creatinine level in postmortem cases.

    Science.gov (United States)

    Nishida, Atsushi; Funaki, Hironao; Kobayashi, Masaki; Tanaka, Yuka; Akasaka, Yoshihisa; Kubo, Toshikazu; Ikegaya, Hiroshi

    2015-05-01

    Blood chemical analysis for the diagnosis of diseases in forensic cases should be conducted in the same way as for clinical cases. However, it is sometimes difficult to obtain serum samples in forensic cases because of postmortem changes such as hemolysis and putrefaction. This study aimed to evaluate renal function in postmortem cases by blood creatinine analysis. The blood creatinine level was measured by high performance liquid chromatography (HPLC) using whole blood samples taken from 77 postmortem cases, and the relationships between blood creatinine level, postmortem interval, and cause of death were examined. The median blood creatinine level was found to be 1.15 mg/dL, with no significant differences between blood samples taken from different parts of the body. The blood creatinine level was stable for 3 days after death and gradually increased after that period, in line with a previous study using enzymatic analysis that found the serum creatinine level was stable in the early postmortem period. The blood creatinine level was high in the cases of blunt injury, intoxication, and in deaths caused by fire. This was considered to reflect acute renal dysfunction. However, the postmortem blood creatinine level remained higher than the clinical normal value despite omitting cases with renal dysfunction from the analysis. Therefore, we next investigated the change in postmortem creatinine levels in mice and found that the blood creatinine level increased with the emergence of rigor mortis. Our findings indicate that HPLC is useful in the postmortem evaluation of renal function even in the cases where serum cannot be obtained. However, the presence of rigor mortis should be considered in the evaluation of blood creatinine values. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  20. Does Ramadan fasting alter body weight and blood lipids and fasting blood glucose in a healthy population? A meta-analysis.

    Science.gov (United States)

    Kul, Seval; Savaş, Esen; Öztürk, Zeynel Abidin; Karadağ, Gülendam

    2014-06-01

    In this study, we conducted a meta-analysis of self-controlled cohort studies comparing body weights, blood levels of lipids and fasting blood glucose levels before and after Ramadan taking into account gender differences. Several databases were searched up to June 2012 for studies showing an effect of Ramadan fasting in healthy subjects, yielding 30 articles. The primary finding of this meta-analysis was that after Ramadan fasting, low-density lipoprotein (SMD = -1.67, 95 % CI = -2.48 to -0.86) and fasting blood glucose levels (SMD = -1.10, 95 % CI = -1.62 to -0.58) were decreased in both sex groups and also in the entire group compared to levels prior to Ramadan. In addition, in the female subgroup, body weight (SMD = -0.04, 95 % CI = -0.20, 0.12), total cholesterol (SMD = 0.05, 95 % CI = -0.51 to 0.60), and triglyceride levels (SMD = 0.03, 95 % CI = -0.31, 0.36) remained unchanged, while HDL levels (SMD = 0.86, 95 % CI = 0.11 to 1.61, p = 0.03) were increased. In males, Ramadan fasting resulted in weight loss (SMD = -0.24, 95 % CI = -0.36, -0.12, p = 0.001). Also, a substantial reduction in total cholesterol (SMD = -0.44, 95 % CI = -0.77 to -0.11) and LDL levels (SMD = -2.22, 95 % CI = -3.47 to -0.96) and a small decrease in triglyceride levels (SMD = -0.35, 95 % CI = -0.67 to -0.02) were observed in males. In conclusion, by looking at this data, it is evident that Ramadan fasting can effectively change body weight and some biochemical parameters in healthy subjects especially in males compared to pre-Ramadan period.

  1. Improved removal of blood contamination from ThinPrep cervical cytology samples for Raman spectroscopic analysis.

    Science.gov (United States)

    Traynor, Damien; Duraipandian, Shiyamala; Martin, Cara M; O'Leary, John J; Lyng, Fiona M

    2018-05-01

    There is an unmet need for methods to help in the early detection of cervical precancer. Optical spectroscopy-based techniques, such as Raman spectroscopy, have shown great potential for diagnosis of different cancers, including cervical cancer. However, relatively few studies have been carried out on liquid-based cytology (LBC) pap test specimens and confounding factors, such as blood contamination, have been identified. Previous work reported a method to remove blood contamination before Raman spectroscopy by pretreatment of the slides with hydrogen peroxide. The aim of the present study was to extend this work to excessively bloody samples to see if these could be rendered suitable for Raman spectroscopy. LBC ThinPrep specimens were treated by adding hydrogen peroxide directly to the vial before slide preparation. Good quality Raman spectra were recorded from negative and high grade (HG) cytology samples with no blood contamination and with heavy blood contamination. Good classification between negative and HG cytology could be achieved for samples with no blood contamination (sensitivity 92%, specificity 93%) and heavy blood contamination (sensitivity 89%, specificity 88%) with poorer classification when samples were combined (sensitivity 82%, specificity 87%). This study demonstrates for the first time the improved potential of Raman spectroscopy for analysis of ThinPrep specimens regardless of blood contamination. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  2. Blood cholesterol and vascular mortality by age, sex, and blood pressure: a meta-analysis of individual data from 61 prospective studies with 55,000 vascular deaths

    DEFF Research Database (Denmark)

    NN, NN; Jensen, Gorm Boje

    2007-01-01

    BACKGROUND: Age, sex, and blood pressure could modify the associations of total cholesterol (and its main two fractions, HDL and LDL cholesterol) with vascular mortality. This meta-analysis combined prospective studies of vascular mortality that recorded both blood pressure and total cholesterol.......65-0.68]), and a sixth (0.83 [0.81-0.85]) lower IHD mortality in both sexes at ages 40-49, 50-69, and 70-89 years, respectively, throughout the main range of cholesterol in most developed countries, with no apparent threshold. The proportional risk reduction decreased with increasing blood pressure, since the absolute......). Total cholesterol was weakly positively related to ischaemic and total stroke mortality in early middle age (40-59 years), but this finding could be largely or wholly accounted for by the association of cholesterol with blood pressure. Moreover, a positive relation was seen only in middle age and only...

  3. Investigating complex patterns of blocked intestinal artery blood pressure signals by empirical mode decomposition and linguistic analysis

    International Nuclear Information System (INIS)

    Yeh, J-R; Lin, T-Y; Shieh, J-S; Chen, Y; Huang, N E; Wu, Z; Peng, C-K

    2008-01-01

    In this investigation, surgical operations of blocked intestinal artery have been conducted on pigs to simulate the condition of acute mesenteric arterial occlusion. The empirical mode decomposition method and the algorithm of linguistic analysis were applied to verify the blood pressure signals in simulated situation. We assumed that there was some information hidden in the high-frequency part of the blood pressure signal when an intestinal artery is blocked. The empirical mode decomposition method (EMD) has been applied to decompose the intrinsic mode functions (IMF) from a complex time series. But, the end effects and phenomenon of intermittence damage the consistence of each IMF. Thus, we proposed the complementary ensemble empirical mode decomposition method (CEEMD) to solve the problems of end effects and the phenomenon of intermittence. The main wave of blood pressure signals can be reconstructed by the main components, identified by Monte Carlo verification, and removed from the original signal to derive a riding wave. Furthermore, the concept of linguistic analysis was applied to design the blocking index to verify the pattern of riding wave of blood pressure using the measurements of dissimilarity. Blocking index works well to identify the situation in which the sampled time series of blood pressure signal was recorded. Here, these two totally different algorithms are successfully integrated and the existence of the existence of information hidden in high-frequency part of blood pressure signal has been proven

  4. Investigating complex patterns of blocked intestinal artery blood pressure signals by empirical mode decomposition and linguistic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, J-R; Lin, T-Y; Shieh, J-S [Department of Mechanical Engineering, Yuan Ze University, 135 Far-East Road, Chung-Li, Taoyuan, Taiwan (China); Chen, Y [Far Eastern Memorial Hospital, Taiwan (China); Huang, N E [Research Center for Adaptive Data Analysis, National Central University, Taiwan (China); Wu, Z [Center for Ocean-Land-Atmosphere Studies (United States); Peng, C-K [Beth Israel Deaconess Medical Center, Harvard Medical School (United States)], E-mail: s939205@ mail.yzu.edu.tw

    2008-02-15

    In this investigation, surgical operations of blocked intestinal artery have been conducted on pigs to simulate the condition of acute mesenteric arterial occlusion. The empirical mode decomposition method and the algorithm of linguistic analysis were applied to verify the blood pressure signals in simulated situation. We assumed that there was some information hidden in the high-frequency part of the blood pressure signal when an intestinal artery is blocked. The empirical mode decomposition method (EMD) has been applied to decompose the intrinsic mode functions (IMF) from a complex time series. But, the end effects and phenomenon of intermittence damage the consistence of each IMF. Thus, we proposed the complementary ensemble empirical mode decomposition method (CEEMD) to solve the problems of end effects and the phenomenon of intermittence. The main wave of blood pressure signals can be reconstructed by the main components, identified by Monte Carlo verification, and removed from the original signal to derive a riding wave. Furthermore, the concept of linguistic analysis was applied to design the blocking index to verify the pattern of riding wave of blood pressure using the measurements of dissimilarity. Blocking index works well to identify the situation in which the sampled time series of blood pressure signal was recorded. Here, these two totally different algorithms are successfully integrated and the existence of the existence of information hidden in high-frequency part of blood pressure signal has been proven.

  5. Quantitative evaluation of blood elements by neutron activation analysis in mice immunized with Bothrops snake venoms

    International Nuclear Information System (INIS)

    Zamboni, C.B.; Metairon, S.; Suzuki, M.F.; Furtado, M.F.; Sant'Anna, O.A.; Tambourgi, D.V.

    2009-01-01

    Mice genetically selected for high antibody responsiveness (HIII) were immunized against different Bothrops species snake venoms from distinct region of Brazil. The Neutron Activation Analysis technique was used to evaluate the whole blood concentrations of elements of clinical relevance [Ca, Cl, K, Mg and Na] in order to establish a potential correlation between antibody response and blood constituents after Bothrops venom administration for clinical screening of envenomed patients. (author)

  6. Physically consistent data assimilation method based on feedback control for patient-specific blood flow analysis.

    Science.gov (United States)

    Ii, Satoshi; Adib, Mohd Azrul Hisham Mohd; Watanabe, Yoshiyuki; Wada, Shigeo

    2018-01-01

    This paper presents a novel data assimilation method for patient-specific blood flow analysis based on feedback control theory called the physically consistent feedback control-based data assimilation (PFC-DA) method. In the PFC-DA method, the signal, which is the residual error term of the velocity when comparing the numerical and reference measurement data, is cast as a source term in a Poisson equation for the scalar potential field that induces flow in a closed system. The pressure values at the inlet and outlet boundaries are recursively calculated by this scalar potential field. Hence, the flow field is physically consistent because it is driven by the calculated inlet and outlet pressures, without any artificial body forces. As compared with existing variational approaches, although this PFC-DA method does not guarantee the optimal solution, only one additional Poisson equation for the scalar potential field is required, providing a remarkable improvement for such a small additional computational cost at every iteration. Through numerical examples for 2D and 3D exact flow fields, with both noise-free and noisy reference data as well as a blood flow analysis on a cerebral aneurysm using actual patient data, the robustness and accuracy of this approach is shown. Moreover, the feasibility of a patient-specific practical blood flow analysis is demonstrated. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Human blood serum analysis using TRXRF

    International Nuclear Information System (INIS)

    Zarkadas, C.; Karydas, A.G.; Paradellis, T.

    2000-01-01

    Total reflection x-ray fluorescence was applied in the analysis of a pool human blood serum sample, which was collected out of 100 healthy individuals during an ordinary day at a hospital in Athens. Direct measurements of 4 1 quantities were performed in a standard TRXRF module, but with the addition of a Mo filter after the cut-off reflector. In this way the exciting beam was further monochromatized leading to an improved peak to background ratio. The elements S, Cl, K, Ca, Fe, Cu, Zn, Se, Br, Rb were detected, with detection limits in the low ppb region for the elements of interest. The determined trace elements concentrations were found to be in very good agreement with values already reported in literature. For intercomparison a quantity of the same sample was freeze dried and measured in a secondary target assembly, in the form of pellets, giving almost identical results. The trace elements concentrations obtained can be considered as representative values for healthy population of Athens and therefore can be used as a monitor in order to associate the lack or excess of certain trace elements with pathological cases. (author)

  8. Scale Space Methods for Analysis of Type 2 Diabetes Patients' Blood Glucose Values

    Directory of Open Access Journals (Sweden)

    Stein Olav Skrøvseth

    2011-01-01

    Full Text Available We describe how scale space methods can be used for quantitative analysis of blood glucose concentrations from type 2 diabetes patients. Blood glucose values were recorded voluntarily by the patients over one full year as part of a self-management process, where the time and frequency of the recordings are decided by the patients. This makes a unique dataset in its extent, though with a large variation in reliability of the recordings. Scale space and frequency space techniques are suited to reveal important features of unevenly sampled data, and useful for identifying medically relevant features for use both by patients as part of their self-management process, and provide useful information for physicians.

  9. Can gingival crevicular blood be relied upon for assessment of blood glucose level?

    Science.gov (United States)

    Dwivedi, Shivani; Verma, Sharmila J; Shah, Monali; Jain, Kapil

    2014-11-01

    Diabetes mellitus (DM) is undiagnosed in approximately half of the patients actually suffering from the disease. In addition, the prevalence of DM is more than twice as high as in patients with periodontitis when compared to periodontally healthy subjects. Thus, a high number of patients with periodontitis may have undiagnosed DM. The purpose of the present study was to evaluate whether blood oozing from a gingival crevice during routine periodontal examination can be used for determining glucose levels. Observational cross-sectional studies were carried out in 75 patients (43 males and 32 females) with chronic periodontitis who were divided into two groups: Group I and Group II, respectively. Blood oozing from the gingival crevices of anterior teeth following periodontal probing was collected with the stick of glucose self-monitoring device, and the blood glucose levels were measured. At the same time, finger-prick blood was taken for glucometric analysis and subsequent readings were recorded. The patient's blood glucose values ranged from 74 to 256 mg/dl. The comparison between gingival crevicular blood and finger-prick blood showed a very strong correlation, with a t value of 3.97 (at P value = 0.001). The data from this study has shown that GCB collected during diagnostic periodontal examination can be an excellent source of blood for glucometric analysis.

  10. Potential biomarkers of tardive dyskinesia: A multiplex analysis of blood serum

    OpenAIRE

    Boiko, Anastasia S; Kornetova, Elena G; Ivanova, Svetlana A.; Loonen, Antonius

    2017-01-01

    Potential biomarkers of tardive dyskinesia: a multiplex analysis of blood serum A.S. Boiko(1), E.G. Kornetova(2), S.A. Ivanova(1), A.J.M. Loonen(3) (1)Mental Health Research Institute, Tomsk National Research Medical Center of the Russian Academy of Sciences, Laboratory of Molecular Genetics and Biochemistry, Tomsk, Russia (2)Mental Health Research Institute, Tomsk National Research Medical Center of the Russian Academy of Sciences, Department of Endogenous Disorders, Tomsk, Russia (3)Univers...

  11. Blood transfusion after percutaneous coronary intervention and risk of subsequent adverse outcomes: a systematic review and meta-analysis.

    Science.gov (United States)

    Kwok, Chun Shing; Sherwood, Matthew W; Watson, Sarah M; Nasir, Samina B; Sperrin, Matt; Nolan, Jim; Kinnaird, Tim; Kiatchoosakun, Songsak; Ludman, Peter F; de Belder, Mark A; Rao, Sunil V; Mamas, Mamas A

    2015-03-01

    This study sought to define the prevalence and prognostic impact of blood transfusions in contemporary percutaneous coronary intervention (PCI) practice. Although the presence of anemia is associated with adverse outcomes in patients undergoing PCI, the optimal use of blood products in patients undergoing PCI remains controversial. A search of EMBASE and MEDLINE was conducted to identify PCI studies that evaluated blood transfusions and their association with major adverse cardiac events (MACE) and mortality. Two independent reviewers screened the studies for inclusion, and data were extracted from relevant studies. Random effects meta-analysis was used to estimate the risk of adverse outcomes with blood transfusions. Statistical heterogeneity was assessed by considering the I(2) statistic. Nineteen studies that included 2,258,711 patients with more than 54,000 transfusion events were identified (prevalence of blood transfusion 2.3%). Crude mortality rate was 6,435 of 50,979 (12.6%, 8 studies) in patients who received a blood transfusion and 27,061 of 2,266,111 (1.2%, 8 studies) in the remaining patients. Crude MACE rates were 17.4% (8,439 of 48,518) in patients who had a blood transfusion and 3.1% (68,062 of 2,212,730) in the remaining cohort. Meta-analysis demonstrated that blood transfusion was independently associated with an increase in mortality (odds ratio: 3.02, 95% confidence interval: 2.16 to 4.21, I(2) = 91%) and MACE (odds ratio: 3.15, 95% confidence interval: 2.59 to 3.82, I(2) = 81%). Similar observations were recorded in studies that adjusted for baseline hematocrit, anemia, and bleeding. Blood transfusion is independently associated with increased risk of mortality and MACE events. Clinicians should minimize the risk for periprocedural transfusion by using available bleeding-avoidance strategies and avoiding liberal transfusion practices. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Association of ABO and Rh Blood Groups to Blood-Borne Infections among Blood Donors in Tehran-Iran.

    Science.gov (United States)

    Mohammadali, Fatemeh; Pourfathollah, Aliakbar

    2014-07-01

    The aim of this study was to investigate the prevalence of hepatitis B, hepatitis C, HIV and syphilis infections in blood donors referred to Tehran Blood Transfusion Center (TBTC), and determine any association between blood groups and blood- borne infections between the years of 2005 and 2011. This was a retrospective study conducted at TBTC. All of the donor serum samples were screened for HBV, HCV, HIV and syphilis by using third generation ELISA kits and RPR test. Initial reactive samples were tested in duplicate. Confirmatory tests were performed on all repeatedly reactive donations. Blood group was determined by forward and reverse blood grouping. The results were subjected to chi square analysis for determination of statistical difference between the values among different categories according to SPSS program. Overall, 2031451 donor serum samples were collected in 2005-2011. Totally, 10451 were positive test for HBV, HCV, HIV and syphilis. The overall seroprevalence of HBV, HCV, HIV, and syphilis was 0.39%, 0.11%, 0.005%, and 0.010%, respectively. Hepatitis B and HIV infections were significantly associated with blood group of donors (P blood group "A" and percentage of HBs Ag was lower in donors who had blood group O. There was no significant association between Hepatitis C and syphilis infections with ABO and Rh blood groups (P>0.05). Compared with neighboring countries and the international standards, prevalence of blood-borne infections is relatively low.

  13. Inferring common cognitive mechanisms from brain blood-flow lateralization data: a new methodology for fTCD analysis.

    Science.gov (United States)

    Meyer, Georg F; Spray, Amy; Fairlie, Jo E; Uomini, Natalie T

    2014-01-01

    Current neuroimaging techniques with high spatial resolution constrain participant motion so that many natural tasks cannot be carried out. The aim of this paper is to show how a time-locked correlation-analysis of cerebral blood flow velocity (CBFV) lateralization data, obtained with functional TransCranial Doppler (fTCD) ultrasound, can be used to infer cerebral activation patterns across tasks. In a first experiment we demonstrate that the proposed analysis method results in data that are comparable with the standard Lateralization Index (LI) for within-task comparisons of CBFV patterns, recorded during cued word generation (CWG) at two difficulty levels. In the main experiment we demonstrate that the proposed analysis method shows correlated blood-flow patterns for two different cognitive tasks that are known to draw on common brain areas, CWG, and Music Synthesis. We show that CBFV patterns for Music and CWG are correlated only for participants with prior musical training. CBFV patterns for tasks that draw on distinct brain areas, the Tower of London and CWG, are not correlated. The proposed methodology extends conventional fTCD analysis by including temporal information in the analysis of cerebral blood-flow patterns to provide a robust, non-invasive method to infer whether common brain areas are used in different cognitive tasks. It complements conventional high resolution imaging techniques.

  14. Urinary and Blood MicroRNA-126 and -770 are Potential Noninvasive Biomarker Candidates for Diabetic Nephropathy: a Meta-Analysis.

    Science.gov (United States)

    Park, Sungjin; Moon, SeongRyeol; Lee, Kiyoung; Park, Ie Byung; Lee, Dae Ho; Nam, Seungyoon

    2018-01-01

    Diabetic nephropathy (DN), a major diabetic microvascular complication, has a long and growing list of biomarkers, including microRNA biomarkers, which have not been consistent across preclinical and clinical studies. This meta-analysis aims to identify significant blood- and urine-incident microRNAs as diagnostic/prognostic biomarker candidates for DN. PubMed, Web of Science, and Cochrane Library were searched from their earliest records through 12th Dec 2016. Relevant publications for the meta-analysis included (1) human participants; (2) microRNAs in blood and urine; (3) DN studies; and (4) English language. Four reviewers, including two physicians, independently and blindly extracted published data regarding microRNA profiles in blood and/or urine from subjects with diabetic nephropathy. A random-effect model was used to pool the data. Statistical associations between diabetic nephropathy and urinary or blood microRNA expression levels were assessed. Fourteen out of 327 studies (n=2,747 patients) were selected. Blood or urinary microRNA expression data of diabetic nephropathy were pooled for this analysis. The hsa-miR-126 family was significantly (OR: 0.57; 95% CI: 0.44-0.74; p-value diabetic kidney disease, while its urinary level was upregulated (OR: 2931.12; 95% CI: 9.96-862623.21; p-value = 0.0059). The hsa-miR-770 family microRNA were significantly (OR: 10.24; 95% CI: 2.37-44.25; p-value = 0.0018) upregulated in both blood and urine from patients with diabetic nephropathy. Our meta-analysis suggests that hsa-miR-126 and hsa-miR-770 family microRNA may have important diagnostic and pathogenetic implications for DN, which warrants further systematic clinical studies. © 2018 The Author(s). Published by S. Karger AG, Basel.

  15. On the suitability of refractometry for the analysis of glucose in blood-derived fluids.

    Science.gov (United States)

    Zirk, K; Poetzschke, H

    2004-07-01

    Refractometry is the determination of the optical refractive index of a substance or a mixture of substances. It is a very sensitive method for the detection and quantification of dissolved analytes, but it is incapable of distinguishing between different analytes. The aim of this investigation was to determine the principle suitability of refractometry for the quantification of glucose (blood sugar) in blood and various blood fluids which can readily be obtained for medical diagnosis, in particular blood plasma, blood serum, and their ultrafiltrates. After the oral intake of freshly dissolved alpha-glucose, the in vivo blood contents of the alpha and beta anomers of glucose were found to be in an at least approximate equilibrium at all times. This observation is a prerequisite for a refractometrical determination of glucose due to the fact that both molecule forms have different refractive index increments. An assessment of the glucose content in untreated blood fluids was not possible, since no suitable relationship to the refractive index was found, most probably due to the influence of the many other substances present in blood on this parameter. However, after removal of certain macromolecules by ultrafiltration, value pairs showed a high level of correlation, providing the nominal molecular weight limit (cut-off) of the ultrafilter used possessed a maximum of 300 kDa. Besides macromolecules, the osmolality of the fluids undergoing measurement also proved to be a considerable interfering factor, particularly when values were outside the normal physiological range between 285 and 293 mmol/L. If a clinical application of this method is to be contemplated it is imperative (1) that blood cells are separated and removed, (2) that macromolecules present in plasma or serum are removed, e.g. by ultrafiltration, and (3) that beyond the results presented the influence of all small molecules other than glucose on the overall refractive index be determined and included in

  16. Biochemical analysis of CTLA-4 immunoreactive material from human blood

    Directory of Open Access Journals (Sweden)

    Dennert Kate

    2009-09-01

    Full Text Available Abstract Background CTLA-4 was initially described as a membrane-bound molecule that inhibited lymphocyte activation by interacting with B7.1 and B7.2 molecules on antigen presenting cells. Alternative splicing of mRNA encoding the CTLA-4 receptor leads to the production of a molecule (sCTLA-4 that lacks a membrane anchor and is therefore secreted into the extracellular space. Despite studies finding that people with autoimmune disease more frequently express high levels of sCTLA-4 in their blood than apparently healthy people, the significance of these findings is unclear. Methods Molecules isolated from blood using CTLA-4 specific antibodies were analyzed with ligand binding assays, mass spectroscopy, and biochemical fractionation in an effort to increase our understanding of CTLA-4 immunoreactive material. Results Mass spectroscopy analysis of the molecules recognized by multiple CTLA-4-specific antibodies failed to identify any CTLA-4 protein. Even though these molecules bind to the CTLA-4 receptors B7.1 and B7.2, they also exhibit properties common to immunoglobulins. Conclusion We have identified molecules in blood that are recognized by CTLA-4 specific antibodies but also exhibit properties of immunoglobulins. Our data indicates that what has been called sCTLA-4 is not a direct product of the CTLA-4 gene, and that the CTLA-4 protein is not part of this molecule. These results may explain why the relationship of sCTLA-4 to immune system activity has been difficult to elucidate.

  17. Improvement of retinal blood vessel detection using morphological component analysis.

    Science.gov (United States)

    Imani, Elaheh; Javidi, Malihe; Pourreza, Hamid-Reza

    2015-03-01

    Detection and quantitative measurement of variations in the retinal blood vessels can help diagnose several diseases including diabetic retinopathy. Intrinsic characteristics of abnormal retinal images make blood vessel detection difficult. The major problem with traditional vessel segmentation algorithms is producing false positive vessels in the presence of diabetic retinopathy lesions. To overcome this problem, a novel scheme for extracting retinal blood vessels based on morphological component analysis (MCA) algorithm is presented in this paper. MCA was developed based on sparse representation of signals. This algorithm assumes that each signal is a linear combination of several morphologically distinct components. In the proposed method, the MCA algorithm with appropriate transforms is adopted to separate vessels and lesions from each other. Afterwards, the Morlet Wavelet Transform is applied to enhance the retinal vessels. The final vessel map is obtained by adaptive thresholding. The performance of the proposed method is measured on the publicly available DRIVE and STARE datasets and compared with several state-of-the-art methods. An accuracy of 0.9523 and 0.9590 has been respectively achieved on the DRIVE and STARE datasets, which are not only greater than most methods, but are also superior to the second human observer's performance. The results show that the proposed method can achieve improved detection in abnormal retinal images and decrease false positive vessels in pathological regions compared to other methods. Also, the robustness of the method in the presence of noise is shown via experimental result. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Clinical Utility of Blood Cell Histogram Interpretation.

    Science.gov (United States)

    Thomas, E T Arun; Bhagya, S; Majeed, Abdul

    2017-09-01

    An automated haematology analyser provides blood cell histograms by plotting the sizes of different blood cells on X-axis and their relative number on Y-axis. Histogram interpretation needs careful analysis of Red Blood Cell (RBC), White Blood Cell (WBC) and platelet distribution curves. Histogram analysis is often a neglected part of the automated haemogram which if interpreted well, has significant potential to provide diagnostically relevant information even before higher level investigations are ordered.

  19. Effect of vitamin D supplementation on blood pressure parameters in patients with vitamin D deficiency: a systematic review and meta-analysis.

    Science.gov (United States)

    Shu, Liqin; Huang, Kun

    2018-07-01

    Evidence suggests that supplementation of vitamin D cannot decrease blood pressure in normal populations. However, in randomized controlled trials (RCTs) with vitamin D deficient participants (defined as baseline serum 25[OH]D levels ScienceDirect, and Cochrane library databases were searched. Extracted data were pooled as weighted mean differences with 95% confidence intervals to evaluate the effects. Subgroup analysis was further conducted according to the characteristics of included studies. Seven RCTs that contained 560 participants were included in our meta-analysis. The pooled weighted mean difference of peripheral diastolic blood pressure was -1.65 mm Hg (95% confidence interval: -3.05 to -0.25, I 2  = 30.3%). No significant effect of vitamin D supplementation was found on other parameters. Subgroup analysis showed a significant decrease in peripheral systolic blood pressure and diastolic blood pressure in Asia, 8 weeks of intervention, and more than 5000 IU of daily vitamin D supplementation subgroups. For vitamin D-deficient patients, there is a small but significant fall in peripheral blood pressure but no significant fall in other blood pressure parameters with vitamin D supplementation. Further RCTs with large numbers of participants is still warranted to confirm these effects. Copyright © 2018 American Heart Association. Published by Elsevier Inc. All rights reserved.

  20. Development of a preparation and staining method for fetal erythroblasts in maternal blood : Simultaneous immunocytochemical staining and FISH analysis

    NARCIS (Netherlands)

    Oosterwijk, JC; Mesker, WE; Ouwerkerk-van Velzen, MCM; Knepfle, CFHM; Wiesmeijer, KC; van den Burg, MJM; Beverstock, GC; Bernini, LF; van Ommen, Gert-Jan B; Kanhai, HHH; Tanke, HJ

    1998-01-01

    In order to detect fetal nucleated red blood cells (NRBCs) in maternal blood, a protocol was developed which aimed at producing a reliable staining method for combined immunocytochemical and FISH analysis. The technique had to be suitable for eventual automated screening of slides. Chorionic villi

  1. The determination of chromium-50 in human blood and its utilization for blood volume measurements

    International Nuclear Information System (INIS)

    Zeisler, R.; Young, I.

    1986-01-01

    Possible relationships between insufficient blood volume increases during pregnancy and infant mortality could be established with an adequate measurement procedure. An accurate and precise technique for blood volume measurements has been found in the isotope dilution technique using chromium-51 as a label for red blood cells. However, in a study involving pregnant women, only stable isotopes can be used for labeling. Stable chromium-50 can be determined in total blood samples before and after dilution experiments by neutron activation analysis (NAA) or mass spectrometry. However, both techniques may be affected by insufficient sensitivity and contamination problems at the inherently low natural chromium concentrations to be measured in the blood. NAA procedures involving irradiations with highly thermalized neutrons at a fluence rate of 2x10 13 n/cm 2 xs and low background gamma spectrometry are applied to the analysis of total blood. Natural levels of chromium-50 in human and animal blood have been found to be <0.1 ng/mL; i.e., total chromium levels of <3 ng/mL. Based on the NAA procedure, a new approach to the blood volume measurement via chromium-50 isotope dilution has been developed which utilizes the ratio of the induced activities of chromium-51 to the iron-59 in three blood samples taken from each individual, namely blank, labeled and diluted labeled blood. (author)

  2. A microfluidic chip for direct and rapid trapping of white blood cells from whole blood

    Science.gov (United States)

    Chen, Jingdong; Chen, Di; Yuan, Tao; Xie, Yao; Chen, Xiang

    2013-01-01

    Blood analysis plays a major role in medical and science applications and white blood cells (WBCs) are an important target of analysis. We proposed an integrated microfluidic chip for direct and rapid trapping WBCs from whole blood. The microfluidic chip consists of two basic functional units: a winding channel to mix and arrays of two-layer trapping structures to trap WBCs. Red blood cells (RBCs) were eliminated through moving the winding channel and then WBCs were trapped by the arrays of trapping structures. We fabricated the PDMS (polydimethylsiloxane) chip using soft lithography and determined the critical flow velocities of tartrazine and brilliant blue water mixing and whole blood and red blood cell lysis buffer mixing in the winding channel. They are 0.25 μl/min and 0.05 μl/min, respectively. The critical flow velocity of the whole blood and red blood cell lysis buffer is lower due to larger volume of the RBCs and higher kinematic viscosity of the whole blood. The time taken for complete lysis of whole blood was about 85 s under the flow velocity 0.05 μl/min. The RBCs were lysed completely by mixing and the WBCs were trapped by the trapping structures. The chip trapped about 2.0 × 103 from 3.3 × 103 WBCs. PMID:24404026

  3. Molecular identification and phylogenetic analysis of Wuchereria bancrofti from human blood samples in Egypt.

    Science.gov (United States)

    Abdel-Shafi, Iman R; Shoieb, Eman Y; Attia, Samar S; Rubio, José M; Ta-Tang, Thuy-Huong; El-Badry, Ayman A

    2017-03-01

    Lymphatic filariasis (LF) is a serious vector-borne health problem, and Wuchereria bancrofti (W.b) is the major cause of LF worldwide and is focally endemic in Egypt. Identification of filarial infection using traditional morphologic and immunological criteria can be difficult and lead to misdiagnosis. The aim of the present study was molecular detection of W.b in residents in endemic areas in Egypt, sequence variance analysis, and phylogenetic analysis of W.b DNA. Collected blood samples from residents in filariasis endemic areas in five governorates were subjected to semi-nested PCR targeting repeated DNA sequence, for detection of W.b DNA. PCR products were sequenced; subsequently, a phylogenetic analysis of the obtained sequences was performed. Out of 300 blood samples, W.b DNA was identified in 48 (16%). Sequencing analysis confirmed PCR results identifying only W.b species. Sequence alignment and phylogenetic analysis indicated genetically distinct clusters of W.b among the study population. Study results demonstrated that the semi-nested PCR proved to be an effective diagnostic tool for accurate and rapid detection of W.b infections in nano-epidemics and is applicable for samples collected in the daytime as well as the night time. PCR products sequencing and phylogenitic analysis revealed three different nucleotide sequences variants. Further genetic studies of W.b in Egypt and other endemic areas are needed to distinguish related strains and the various ecological as well as drug effects exerted on them to support W.b elimination.

  4. Direct speciation analysis of arsenic in whole blood and blood plasma at low exposure levels by hydride generation-cryotrapping-inductively coupled plasma mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Matoušek, Tomáš; Wang, Z.; Douillet, Ch.; Musil, Stanislav; Stýblo, M.

    2017-01-01

    Roč. 89, č. 18 (2017), s. 9633-9637 ISSN 0003-2700 R&D Projects: GA MŠk(CZ) LH15174 Institutional support: RVO:68081715 Keywords : speciation analysis * arsenic * blood Subject RIV: CB - Analytical Chemistry , Separation OBOR OECD: Analytical chemistry Impact factor: 6.320, year: 2016

  5. Direct speciation analysis of arsenic in whole blood and blood plasma at low exposure levels by hydride generation-cryotrapping-inductively coupled plasma mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Matoušek, Tomáš; Wang, Z.; Douillet, Ch.; Musil, Stanislav; Stýblo, M.

    2017-01-01

    Roč. 89, č. 18 (2017), s. 9633-9637 ISSN 0003-2700 R&D Projects: GA MŠk(CZ) LH15174 Institutional support: RVO:68081715 Keywords : speciation analysis * arsenic * blood Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 6.320, year: 2016

  6. Blood transport method for chromosome analysis of residents living near Semipalatinsk nuclear test site.

    Science.gov (United States)

    Rodzi, Mohd; Ihda, Shozo; Yokozeki, Masako; Takeichi, Nobuo; Tanaka, Kimio; Hoshi, Masaharu

    2009-12-01

    A study was conducted to compare the storage conditions and transportation period for blood samples collected from residents living in areas near the Semipalatinsk nuclear test site (SNTS). Experiments were performed to simulate storage and shipping environments. Phytohaemagglutinin (PHA)-stimulated blood was stored in 15-ml tubes (condition A: current transport method) in the absence or in 50-ml flasks (condition B: previous transport method) in the presence of RPMI-1640 and 20% fetal bovine serum (FBS). Samples were kept refrigerated at 4 degrees C and cell viability was assessed after 3, 8, 12 and 14 days of storage. RPMI-1640, 20% FBS and further PHA were added to blood samples under condition A in 50-ml flasks for culture. Whole-blood samples under condition B were directly incubated without further sub-culturing process, neither media nor PHA were added, to adopt a similar protocol to that employed in the previous transport method. Samples in condition A and condition B were incubated for 48 hr at 37 degrees C and their mitotic index was determined. The results showed that viable lymphocytes were consistent in both storage conditions but the mitotic index was higher in condition A than in condition B. Although further confirmation studies have to be carried out, previous chromosomal studies and the present experiment have shown that PHA-stimulated blood could be stored without culture medium for up to 8 days under condition A. The present results will be useful for cytogenetic analysis of blood samples that have been transported long distances wherever a radiation accident has occurred.

  7. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    Science.gov (United States)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  8. Longitudinal peripheral blood transcriptional analysis of a patient with severe Ebola virus disease.

    Science.gov (United States)

    Kash, John C; Walters, Kathie-Anne; Kindrachuk, Jason; Baxter, David; Scherler, Kelsey; Janosko, Krisztina B; Adams, Rick D; Herbert, Andrew S; James, Rebekah M; Stonier, Spencer W; Memoli, Matthew J; Dye, John M; Davey, Richard T; Chertow, Daniel S; Taubenberger, Jeffery K

    2017-04-12

    The 2013-2015 outbreak of Ebola virus disease in Guinea, Liberia, and Sierra Leone was unprecedented in the number of documented cases, but there have been few published reports on immune responses in clinical cases and their relationships with the course of illness and severity of Ebola virus disease. Symptoms of Ebola virus disease can include severe headache, myalgia, asthenia, fever, fatigue, diarrhea, vomiting, abdominal pain, and hemorrhage. Although experimental treatments are in development, there are no current U.S. Food and Drug Administration-approved vaccines or therapies. We report a detailed study of host gene expression as measured by microarray in daily peripheral blood samples collected from a patient with severe Ebola virus disease. This individual was provided with supportive care without experimental therapies at the National Institutes of Health Clinical Center from before onset of critical illness to recovery. Pearson analysis of daily gene expression signatures revealed marked gene expression changes in peripheral blood leukocytes that correlated with changes in serum and peripheral blood leukocytes, viral load, antibody responses, coagulopathy, multiple organ dysfunction, and then recovery. This study revealed marked shifts in immune and antiviral responses that preceded changes in medical condition, indicating that clearance of replicating Ebola virus from peripheral blood leukocytes is likely important for systemic viral clearance. Copyright © 2017, American Association for the Advancement of Science.

  9. Comparison between autologous blood transfusion drainage and closed-suction drainage/no drainage in total knee arthroplasty: a meta-analysis.

    Science.gov (United States)

    Hong, Kun-Hao; Pan, Jian-Ke; Yang, Wei-Yi; Luo, Ming-Hui; Xu, Shu-Chai; Liu, Jun

    2016-08-01

    Autologous blood transfusion (ABT) drainage system is a new unwashed salvaged blood retransfusion system for total knee replacement (TKA). However, whether to use ABT drainage, closed-suction (CS) drainage or no drainage in TKA surgery remains controversial. This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT drains compared with closed-suction/no drainage. PubMed, Embase, and the Cochrane Library were comprehensively searched in March 2015. Fifteen randomized controlled trials (RCTs) were identified and pooled for statistical analysis. The primary outcome evaluated was homologous blood transfusion rate. The secondary outcomes were post-operative haemoglobin on days 3-5, length of hospital stay and wound infections after TKA surgery. The pooled data included 1,721 patients and showed that patients in the ABT drainage group might benefit from lower blood transfusion rates (16.59 % and 37.47 %, OR: 0.28 [0.14, 0.55]; 13.05 % and 16.91 %, OR: 0.73 [0.47,1.13], respectively). Autologous blood transfusion drainage and closed-suction drainage/no drainage have similar clinical efficacy and safety with regard to post-operative haemoglobin on days 3-5, length of hospital stay and wound infections. Autologous blood transfusion drainage offers a safe and efficient alternative to CS/no drainage with a lower blood transfusion rate. Future large-volume high-quality RCTs with extensive follow-up will affirm and update this system review.

  10. Analysis of 24-Hour Ambulatory Blood Pressure Monitoring Data using Orthonormal Polynomials in the Linear Mixed Model

    OpenAIRE

    Edwards, Lloyd J.; Simpson, Sean L.

    2010-01-01

    The use of 24-hour ambulatory blood pressure monitoring (ABPM) in clinical practice and observational epidemiological studies has grown considerably in the past 25 years. ABPM is a very effective technique for assessing biological, environmental, and drug effects on blood pressure. In order to enhance the effectiveness of ABPM for clinical and observational research studies via analytical and graphical results, developing alternative data analysis approaches are important. The linear mixed mo...

  11. Effects of endurance training on blood pressure, blood pressure-regulating mechanisms, and cardiovascular risk factors.

    Science.gov (United States)

    Cornelissen, Véronique A; Fagard, Robert H

    2005-10-01

    Previous meta-analyses of randomized controlled trials on the effects of chronic dynamic aerobic endurance training on blood pressure reported on resting blood pressure only. Our aim was to perform a comprehensive meta-analysis including resting and ambulatory blood pressure, blood pressure-regulating mechanisms, and concomitant cardiovascular risk factors. Inclusion criteria of studies were: random allocation to intervention and control; endurance training as the sole intervention; inclusion of healthy sedentary normotensive or hypertensive adults; intervention duration of > or =4 weeks; availability of systolic or diastolic blood pressure; and publication in a peer-reviewed journal up to December 2003. The meta-analysis involved 72 trials, 105 study groups, and 3936 participants. After weighting for the number of trained participants and using a random-effects model, training induced significant net reductions of resting and daytime ambulatory blood pressure of, respectively, 3.0/2.4 mm Hg (Phypertensive study groups (-6.9/-4.9) than in the others (-1.9/-1.6; Pendurance training decreases blood pressure through a reduction of vascular resistance, in which the sympathetic nervous system and the renin-angiotensin system appear to be involved, and favorably affects concomitant cardiovascular risk factors.

  12. Dried Blood Spot Proteomics: Surface Extraction of Endogenous Proteins Coupled with Automated Sample Preparation and Mass Spectrometry Analysis

    Science.gov (United States)

    Martin, Nicholas J.; Bunch, Josephine; Cooper, Helen J.

    2013-08-01

    Dried blood spots offer many advantages as a sample format including ease and safety of transport and handling. To date, the majority of mass spectrometry analyses of dried blood spots have focused on small molecules or hemoglobin. However, dried blood spots are a potentially rich source of protein biomarkers, an area that has been overlooked. To address this issue, we have applied an untargeted bottom-up proteomics approach to the analysis of dried blood spots. We present an automated and integrated method for extraction of endogenous proteins from the surface of dried blood spots and sample preparation via trypsin digestion by use of the Advion Biosciences Triversa Nanomate robotic platform. Liquid chromatography tandem mass spectrometry of the resulting digests enabled identification of 120 proteins from a single dried blood spot. The proteins identified cross a concentration range of four orders of magnitude. The method is evaluated and the results discussed in terms of the proteins identified and their potential use as biomarkers in screening programs.

  13. [Prehospital arterial blood gas analysis after collapse connected to triathlon participation].

    Science.gov (United States)

    Ettrup-Christensen, Asbjørn; Amstrup-Hansen, Louise; Zwisler, Stine T

    2017-05-01

    Long-distance athletes are at risk of serious fluid and electrolyte disturbances, such as hypernatraemia (dehydration). Recently, cases of serious morbidity have been reported, due to acute exercise-associated hyponatraemia, which can advance to encephalopathy. An arterial blood gas analysis (ABG) was drawn from collapsed athletes at the championship of full-distance triathlon 2015, and different electrolyte imbalances were found. Our findings show that prehospital ABG can assist in differentiating the cause of collapse, and presumably, targeted treatment can be initiated already on scene.

  14. Nanoscale Test Strips for Multiplexed Blood Analysis

    Science.gov (United States)

    Chan, Eugene

    2015-01-01

    A critical component of the DNA Medicine Institute's Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) sensor are nanoscale test strips, or nanostrips, that enable multiplexed blood analysis. Nanostrips are conceptually similar to the standard urinalysis test strip, but the strips are shrunk down a billionfold to the microscale. Each nanostrip can have several sensor pads that fluoresce in response to different targets in a sample. The strips carry identification tags that permit differentiation of a specific panel from hundreds of other nanostrip panels during a single measurement session. In Phase I of the project, the company fabricated, tested, and demonstrated functional parathyroid hormone and vitamin D nanostrips for bone metabolism, and thrombin aptamer and immunoglobulin G antibody nanostrips. In Phase II, numerous nanostrips were developed to address key space flight-based medical needs: assessment of bone metabolism, immune response, cardiac status, liver metabolism, and lipid profiles. This unique approach holds genuine promise for space-based portable biodiagnostics and for point-of-care (POC) health monitoring and diagnostics here on Earth.

  15. Peripheral blood collection

    DEFF Research Database (Denmark)

    Franken, Carmen; Remy, Sylvie; Lambrechts, Nathalie

    2016-01-01

    A crucial challenge for gene expression analysis in human biomonitoring studies on whole blood samples is rapid sample handling and mRNA stabilization. This study was designed to evaluate the impact of short bench times (less than 30 min) on yield, quality and gene expression of mRNA in the prese......A crucial challenge for gene expression analysis in human biomonitoring studies on whole blood samples is rapid sample handling and mRNA stabilization. This study was designed to evaluate the impact of short bench times (less than 30 min) on yield, quality and gene expression of m......RNA in the presence of different stabilization buffers (TempusTM Blood RNA tube and RNAlater® Stabilization Reagent). Microarray analyzes showed significant changes over short periods of time in expression of a considerate part of the transcriptome (2356 genes) with a prominent role for NFкB-, cancer......- and glucocorticoid-mediated networks, and specifically interleukin-8 (IL-8). These findings suggest that even short bench times affect gene expression, requiring to carry out blood collection in a strictly standardized way. © 2016 Informa UK Limited, trading as Taylor & Francis Group....

  16. [Investigation of reference intervals of blood gas and acid-base analysis assays in China].

    Science.gov (United States)

    Zhang, Lu; Wang, Wei; Wang, Zhiguo

    2015-10-01

    To investigate and analyze the upper and lower limits and their sources of reference intervals in blood gas and acid-base analysis assays. The data of reference intervals were collected, which come from the first run of 2014 External Quality Assessment (EQA) program in blood gas and acid-base analysis assays performed by National Center for Clinical Laboratories (NCCL). All the abnormal values and errors were eliminated. Data statistics was performed by SPSS 13.0 and Excel 2007 referring to upper and lower limits of reference intervals and sources of 7 blood gas and acid-base analysis assays, i.e. pH value, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), Na+, K+, Ca2+ and Cl-. Values were further grouped based on instrument system and the difference between each group were analyzed. There were 225 laboratories submitting the information on the reference intervals they had been using. The three main sources of reference intervals were National Guide to Clinical Laboratory Procedures [37.07% (400/1 079)], instructions of instrument manufactures [31.23% (337/1 079)] and instructions of reagent manufactures [23.26% (251/1 079)]. Approximately 35.1% (79/225) of the laboratories had validated the reference intervals they used. The difference of upper and lower limits in most assays among 7 laboratories was moderate, both minimum and maximum (i.e. the upper limits of pH value was 7.00-7.45, the lower limits of Na+ was 130.00-156.00 mmol/L), and mean and median (i.e. the upper limits of K+ was 5.04 mmol/L and 5.10 mmol/L, the upper limits of PCO2 was 45.65 mmHg and 45.00 mmHg, 1 mmHg = 0.133 kPa), as well as the difference in P2.5 and P97.5 between each instrument system group. It was shown by Kruskal-Wallis method that the P values of upper and lower limits of all the parameters were lower than 0.001, expecting the lower limits of Na+ with P value 0.029. It was shown by Mann-Whitney that the statistic differences were found among instrument

  17. Efficient and Specific Analysis of Red Blood Cell Glycerophospholipid Fatty Acid Composition

    OpenAIRE

    Klem, Sabrina; Klingler, Mario; Demmelmair, Hans; Koletzko, Berthold

    2012-01-01

    BACKGROUND: Red blood cell (RBC) n-3 fatty acid status is related to various health outcomes. Accepted biological markers for the fatty acid status determination are RBC phospholipids, phosphatidylcholine, and phosphatidyletholamine. The analysis of these lipid fractions is demanding and time consuming and total phospholipid n-3 fatty acid levels might be affected by changes of sphingomyelin contents in the RBC membrane during n-3 supplementation. AIM: We developed a method for the specific a...

  18. Functional proteomic analysis of Ankaferd® Blood Stopper

    Directory of Open Access Journals (Sweden)

    Duygu Özel Demiralp

    2010-06-01

    Full Text Available Objective: Ankaferd® Blood Stopper (ABS comprises a standardized mixture of the plants Thymus vulgaris, Glycyrrhiza glabra, Vitis vinifera, Alpinia officinarum, and Urtica dioica. The basic mechanism of action for ABS is the formation of an encapsulated protein network that provides focal points for vital erythrocyte aggregation. ABS–induced protein network formation with blood cells, particularly erythrocytes, covers the primary and secondary hemostatic system without disturbing individual coagulation factors. Materials and Methods: To understand the effect mechanisms of ABS on hemostasis, a proteomic analysis using 2D gel electrophoresis and mass spectrometer was performed. Results: Proteins of plant origin in Ankaferd® were NADP-dependent-malic enzyme, ribulose bisphosphate-carboxylase-large chain, maturase K, ATP synthase subunit-beta, ATP synthase subunit-alpha, chalcone-flavanone isomerase-1, chalcone-flavanone isomerase-2, and actin-depolymerizing factor. Furthermore, functional proteomic studies revealed that proteins resembling human peptides have been detected within Ankaferd®, including ATP synthase, mucin-16 (CD164 sialomucin-like 2 protein, coiled-coil domain containing 141 hypothetical protein LOC283638 isoform 1, hypothetical protein LOC283638 isoform 2, dynactin 5, complex I intermediate-associated protein 30, mitochondrial, NADH dehydrogenase (ubiquinone 1 alpha subcomplex, TP synthase, H+ transporting, mitochondrial actin binding 1 isoform, LIM domain and actin binding 1 isoform a, LIM domain and actin binding 1 isoform b, spectrin alpha non erythrocytic 1, prolactin releasing hormone receptor, utrophin, tet oncogene family member 2 isoform b, protein phosphatase 1 regulatory subunit 12A, NIMA (never in mitosis gene a-related kinase, ATP-binding cassette protein C12, Homo sapiens malic enzyme 1, mitochondrial NADP(+-dependent malic enzyme 3, ME2 protein, nuclear factor 1 B-type, abhydrolase domain-containing protein 12B, E

  19. Application of wavelet analysis to detect dysfunction in cerebral blood flow autoregulation during experimental hyperhomocysteinaemia.

    Science.gov (United States)

    Aleksandrin, Valery V; Ivanov, Alexander V; Virus, Edward D; Bulgakova, Polina O; Kubatiev, Aslan A

    2018-04-03

    The purpose of the present study was to investigate the use of laser Doppler flowmetry (LDF) signals coupled with spectral wavelet analysis to detect endothelial link dysfunction in the autoregulation of cerebral blood flow in the setting of hyperhomocysteinaemia (HHcy). Fifty-one rats were assigned to three groups (intact, control, and HHcy) according to the results of biochemical assays of homocysteine level in blood plasma. LDF signals on the rat brain were recorded by LAKK-02 device to measure the microcirculatory blood flow. The laser operating wavelength and output power density were1064 nm and 0.051 W/mm 2 , respectively. A Morlet mother wavelet transform was applied to the measured 8-min LDF signals, and periodic oscillations with five frequency intervals were identified (0.01-0.04 Hz, 0.04-0.15 Hz, 0.15-0.4 Hz, 0.4-2 Hz, and 2-5 Hz) corresponding to endothelial, neurogenic, myogenic, respiratory, and cardiac origins, respectively. In initial state, the amplitude of the oscillations decreased by 38% (P wavelet analysis may be successfully applied to detect the dysfunction of the endothelial link in cerebral vessel tone and to reveal the pathological shift of lower limit of autoregulation.

  20. Comparative transcriptomic analysis of endothelial progenitor cells derived from umbilical cord blood and adult peripheral blood: Implications for the generation of induced pluripotent stem cells

    Directory of Open Access Journals (Sweden)

    Xiugong Gao

    2017-12-01

    Full Text Available Induced pluripotent stem cells (iPSCs offer the potential to generate tissues with ethnic diversity enabling toxicity testing on selected populations. Recently, it has been reported that endothelial progenitor cells (EPCs derived from umbilical cord blood (CB or adult peripheral blood (PB afford a practical and efficient cellular substrate for iPSC generation. However, differences between EPCs from different blood sources have rarely been studied. In the current study, we derived EPCs from blood mononuclear cells (MNCs and reprogrammed EPCs into iPSCs. We also explored differences between CB-EPCs and PB-EPCs at the molecular and cellular levels through a combination of transcriptomic analysis and cell biology techniques. EPC colonies in CB-MNCs emerged 5–7 days earlier, were 3-fold higher in number, and consistently larger in size than in PB-MNCs. Similarly, iPSC colonies generated from CB-EPCs was 2.5-fold higher in number than from PB-EPCs, indicating CB-EPCs have a higher reprogramming efficiency than PB-EPCs. Transcriptomic analysis using microarrays found a total of 1133 genes differentially expressed in CB-EPCs compared with PB-EPCs, with 675 genes upregulated and 458 downregulated. Several canonical pathways were impacted, among which the human embryonic stem cell pluripotency pathway was of particular interest. The differences in the gene expression pattern between CB-EPCs and PB-EPCs provide a molecular basis for the discrepancies seen in their derivation and reprogramming efficiencies, and highlight the advantages of using CB as the cellular source for the generation of iPSCs and their derivative tissues for ethnic-related toxicological applications.

  1. Comparative transcriptomic analysis of endothelial progenitor cells derived from umbilical cord blood and adult peripheral blood: Implications for the generation of induced pluripotent stem cells.

    Science.gov (United States)

    Gao, Xiugong; Yourick, Jeffrey J; Sprando, Robert L

    2017-12-01

    Induced pluripotent stem cells (iPSCs) offer the potential to generate tissues with ethnic diversity enabling toxicity testing on selected populations. Recently, it has been reported that endothelial progenitor cells (EPCs) derived from umbilical cord blood (CB) or adult peripheral blood (PB) afford a practical and efficient cellular substrate for iPSC generation. However, differences between EPCs from different blood sources have rarely been studied. In the current study, we derived EPCs from blood mononuclear cells (MNCs) and reprogrammed EPCs into iPSCs. We also explored differences between CB-EPCs and PB-EPCs at the molecular and cellular levels through a combination of transcriptomic analysis and cell biology techniques. EPC colonies in CB-MNCs emerged 5-7days earlier, were 3-fold higher in number, and consistently larger in size than in PB-MNCs. Similarly, iPSC colonies generated from CB-EPCs was 2.5-fold higher in number than from PB-EPCs, indicating CB-EPCs have a higher reprogramming efficiency than PB-EPCs. Transcriptomic analysis using microarrays found a total of 1133 genes differentially expressed in CB-EPCs compared with PB-EPCs, with 675 genes upregulated and 458 downregulated. Several canonical pathways were impacted, among which the human embryonic stem cell pluripotency pathway was of particular interest. The differences in the gene expression pattern between CB-EPCs and PB-EPCs provide a molecular basis for the discrepancies seen in their derivation and reprogramming efficiencies, and highlight the advantages of using CB as the cellular source for the generation of iPSCs and their derivative tissues for ethnic-related toxicological applications. Published by Elsevier B.V.

  2. The cost of blood collection in Greece: an economic analysis.

    Science.gov (United States)

    Fragoulakis, Vassilis; Stamoulis, Kostas; Grouzi, Elisabeth; Maniadakis, Nikolaos

    2014-07-01

    The goal of this study was to estimate the cost of production of 1 unit of blood from a National Health Service perspective in Greece. In agreement with guidelines, the cost of blood production in this study accounted only for the resources expended for collection, processing, laboratory testing, and storage. Hence, the costs associated with donor recruitment, pretransfusion preparation, transfusion administration, follow-up management of adverse events, and other long-term relevant costs were not taken into consideration. The indirect cost of blood donations for donors (productivity loss) was also considered. A questionnaire was used to collect data regarding personnel time, annual blood quantities collected, percentage of wastage, utilization of consumables, institutional overhead, information technology expenditure, medical equipment utilized, nuclear acid tests, and other factors. Data gathered by 53 hospitals across the country were assessed. A model was constructed with economic data collected by the National School of Public Health and the Ministry of Health. All data refer to the year 2013. The weighted mean direct cost of producing 1 unit of blood was estimated at €131.49 (SD, €22.12; minimum/maximum, €94.96-€239.20). The mean total indirect cost was estimated at €34 per unit of blood. The cost distribution was positively skewed (skewness, 1.642 [0.327]). The major cost component was the cost of personnel, accounting for 32.5% of total costs, and the average of blood unit wastage was estimated at 4.90%. There were no differences between the cost of producing 1 unit of blood in Athens compared with the rest of the country (Mann-Whitney test, P = 0.341). This study suggests that the cost of producing 1 unit of blood is not insignificant. These figures need to be complemented with those concerning the cost of transfusion to have a complete picture of producing and using 1 unit of blood locally. Copyright © 2014 Elsevier HS Journals, Inc. All

  3. Neutron activation analysis of Cl, K and Na content in whole blood of horses used in hyperimmune sera production

    International Nuclear Information System (INIS)

    Baptista, T.S.; Zamboni, C.B.; Medeiros, J.A.G.; Freitas, M.G.; Higashi, H.G.; Marcelino, J.R.

    2009-01-01

    Using neutron activation analysis technique Cl, K and Na concentration were obtained in whole blood of equines used for antivenom production at Butantan Institute (Sao Paulo, Brazil). These data were compared with the human whole blood estimation. No significant difference was observed suggesting that this model animal is adequate sera production. (author)

  4. Direct chromatographic analysis of metabolites of lipophilic tracers in whole blood by ISRP chromatography

    International Nuclear Information System (INIS)

    Rosenspire, K.C.; Hirth, W.; Jurisson, S.; Nowotnik, D.P.; Eckelman, W.C.; Nunn, A.D.

    1991-01-01

    HPLC using columns packed with 5 μ Internal Surface Reverse Phase (ISRP) resin have shown utility in the analysis of lipophilic drugs and their metabolites by direct injection of serum or plasma samples. We have developed a method for rapid on-line separation of small hydrophobic components from cellular whole blood components. This is achieved through the use of 75 μ GFF (glycine-phenylalanine-phenylalanine) glass bead ISRP chromatographic material packed into a small HPLC column, and used in conjunction with an HPLC system containing a switching valve and a second analytical column. When heparinized whole blood is applied to a 75 μ GFF ISRP column, and the column eluted with an isotonic eluent, lipophilic compounds free in plasma are retained by the column, while plasma proteins, blood cells, and compounds bound to these blood components pass through the ISRP column. Following the elution of these components, the lipophilic compounds retained on the ISRP column are eluted by increasing the percentage of organic solvent in the eluent, and are further resolved (if required) by the analytical column. We have applied this analytical method to the study of metabolism of the 99m Tc-BATO (Boronic acid Adducts of Technetium diOxime) cerebral and myocardial perfusion tracers. (author)

  5. Blood management and transfusion strategies in 600 patients undergoing total joint arthroplasty: an analysis of pre-operative autologous blood donation.

    Science.gov (United States)

    Perazzo, Paolo; Viganò, Marco; De Girolamo, Laura; Verde, Francesco; Vinci, Anna; Banfi, Giuseppe; Romagnoli, Sergio

    2013-07-01

    Blood loss during total joint arthroplasty strongly influences the time to recover after surgery and the quality of the recovery. Blood conservation strategies such as pre-operative autologous blood donation and post-operative cell salvage are intended to avoid allogeneic blood transfusions and their associated risks. Although widely investigated, the real effectiveness of these alternative transfusion practices remains controversial. The surgery reports of 600 patients undergoing total joint arthroplasty (312 hip and 288 knee replacements) were retrospectively reviewed to assess transfusion needs and related blood management at our institute. Evaluation parameters included post-operative blood loss, haemoglobin concentration measured at different time points, ASA score, and blood transfusion strategies. Autologous blood donation increased the odds of receiving a red blood cell transfusion. Reinfusion by a cell salvage system of post-operative shed blood was found to limit adverse effects in cases of severe post-operative blood loss. The peri-operative net decrease in haemoglobin concentration was higher in patients who had predeposited autologous blood than in those who had not. The strengths of this study are the high number of cases and the standardised procedures, all operations having been performed by a single orthopaedic surgeon and a single anaesthesiologist. Our data suggest that a pre-operative autologous donation programme may often be useless, if not harmful. Conversely, the use of a cell salvage system may be effective in reducing the impact of blood transfusion on a patient's physiological status. Basal haemoglobin concentration emerged as a useful indicator of transfusion probability in total joint replacement procedures.

  6. Determination of reference values of elements in whole blood of the wistar rats using neutron activation analysis (NAA)

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Laura C.; Zamboni, Cibele B., E-mail: laura@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    Some investigations, especially biochemistry analysis, can be performed using whole blood if the normality limits are established. The present study deals with the determination of reference values for elements of clinical interest, in whole blood of Wistar rats using the Neutron Activation Analysis technique. Usually these small-sized animals are used as guinea-pig on experiments that involves testing new medicines and medical diagnostic studies. In this investigation, the reference values for blood were determined for: Br (0.0011 - 0.0095 gL{sup -1}), Ca (0.0 - 0.66 gL{sup -1}), Cl (2.35 - 4.91 gL{sup -1}), K (1.00 - 3.12 gL{sup -1}), Mg (0.044 - 0.108 gL{sup -1}), Na (1.13 - 3.09 gL{sup -1}) and S (0.53 - 1.81 gL{sup -1}). These data will allow researchers to optimize their studies, both in terms of cost and time by selecting species that fits to the experimental model as a clinical reference as well as performing biochemical analyses in whole blood using small quantities (few {mu}L) compared to the conventional analyses performed in serum (few mL). (author)

  7. Determination of reference values of elements in whole blood of the wistar rats using neutron activation analysis (NAA)

    International Nuclear Information System (INIS)

    Oliveira, Laura C.; Zamboni, Cibele B.

    2011-01-01

    Some investigations, especially biochemistry analysis, can be performed using whole blood if the normality limits are established. The present study deals with the determination of reference values for elements of clinical interest, in whole blood of Wistar rats using the Neutron Activation Analysis technique. Usually these small-sized animals are used as guinea-pig on experiments that involves testing new medicines and medical diagnostic studies. In this investigation, the reference values for blood were determined for: Br (0.0011 - 0.0095 gL -1 ), Ca (0.0 - 0.66 gL -1 ), Cl (2.35 - 4.91 gL -1 ), K (1.00 - 3.12 gL -1 ), Mg (0.044 - 0.108 gL -1 ), Na (1.13 - 3.09 gL -1 ) and S (0.53 - 1.81 gL -1 ). These data will allow researchers to optimize their studies, both in terms of cost and time by selecting species that fits to the experimental model as a clinical reference as well as performing biochemical analyses in whole blood using small quantities (few μL) compared to the conventional analyses performed in serum (few mL). (author)

  8. Comparison of utility of blood cultures from intravascular catheters and peripheral veins: a systematic review and decision analysis.

    Science.gov (United States)

    Falagas, Matthew E; Kazantzi, Maria S; Bliziotis, Ioannis A

    2008-01-01

    Blood cultures are sometimes obtained from intravascular catheters for convenience. However, there is controversy regarding this practice. The authors compared the diagnostic test characteristics of blood cultures obtained from intravascular catheters and peripheral veins. Relevant studies for inclusion in this review were identified through PubMed (January 1970-October 2005) and the Cochrane Central Register of Controlled Trials. Studies that reported clear definitions of true bacteraemia were included in the analysis. Two reviewers independently extracted the data. Six studies were included in the analysis, providing data for 2677 pairs of blood cultures obtained from an intravascular catheter and a peripheral venipuncture. A culture obtained from an intravascular catheter was found to be a diagnostic test for bacteraemia with better sensitivity (OR 1.85, 95 % CI 1.14-2.99, fixed effects model) and better negative predictive value (almost with statistical significance) (OR 1.55, 95 % CI 0.999-2.39, fixed effects model) but with less specificity (OR 0.33, 95 % CI 0.18-0.59, random effects model) and lower positive predictive value (OR 0.41, 95 % CI 0.23-0.76, random effects model) compared to a culture taken by peripheral venipuncture. In a group of 1000 patients, eight additional patients with true bacteraemia would be identified and 59 falsely diagnosed as having bacteraemia by a blood culture obtained from an intravascular catheter compared to results of the peripheral blood culture. Given the consequences of undertreating patients with bacteraemia, the authors believe that, based on the available evidence, at least one blood culture should be obtained from the intravascular catheter.

  9. Hematocrit analysis through the use of an inexpensive centrifugal polyester-toner device with finger-to-chip blood loading capability

    International Nuclear Information System (INIS)

    Thompson, Brandon L.; Gilbert, Rachel J.; Mejia, Maximo; Shukla, Nishant; Haverstick, Doris M.; Garner, Gavin T.; Landers, James P.

    2016-01-01

    Hematocrit (HCT) measurements are important clinical diagnostic variables that help physicians diagnose and treat various medical conditions, ailments, and diseases. In this work, we present the HCT Disc, a centrifugal microdevice fabricated by a Print, Cut and Laminate (PCL) method to generate a 12-sample HCT device from materials costing <0.5 USD (polyester and toner or PeT). Following introduction from a drop of blood (finger stick), whole blood metering and cell sedimentation are controlled by centrifugal force, only requiring a CD player motor as external hardware and, ultimately, a cell phone for detection. The sedimented volume from patient blood in the HCT Disc was analyzed using a conventional scanner/custom algorithm for analysis of the image to determine a hematocrit value, and these were compared to values generated in a clinical laboratory, which correlated well. To enhance portability and assure simplicity of the HCT measurement, values from image analysis by a cell phone using a custom application was compared to the scanner. Fifteen samples were analyzed with cell phone image analysis system and were found to be within 4% of the HCT values determined in the clinical lab. We demonstrate the feasibility of the PeT device for HCT measurement, and highlight its uniquely low cost (<0.5 USD), speed (sample-to-answer <8 min), multiplexability (12 samples), low volume whole blood requirement (<3 μL), rotation speeds (<4000 rpm) needed for effective measurement as well as the direct finger-to-chip sample loading capability. - Highlights: • A 12-sample hematocrit device was developed from polyester-toner materials. • The device can analyze a patient's hematocrit within 8 min from 3 μL of blood. • Cell phone image analysis is used to correctly determine clinical hematocrits.

  10. Hematocrit analysis through the use of an inexpensive centrifugal polyester-toner device with finger-to-chip blood loading capability

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Brandon L.; Gilbert, Rachel J. [Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904 (United States); Mejia, Maximo [Department of Mechanical Engineering, Engineer' s Way, University of Virginia, Charlottesville, VA 22904 (United States); Shukla, Nishant [Department of Computer Science, Engineer' s Way, University of Virginia, Charlottesville, VA 22904 (United States); Haverstick, Doris M. [Department of Pathology, University of Virginia Health Science Center, Charlottesville, VA 22908 (United States); Garner, Gavin T. [Department of Mechanical Engineering, Engineer' s Way, University of Virginia, Charlottesville, VA 22904 (United States); Landers, James P., E-mail: landers@virginia.edu [Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904 (United States); Department of Mechanical Engineering, Engineer' s Way, University of Virginia, Charlottesville, VA 22904 (United States); Department of Pathology, University of Virginia Health Science Center, Charlottesville, VA 22908 (United States)

    2016-06-14

    Hematocrit (HCT) measurements are important clinical diagnostic variables that help physicians diagnose and treat various medical conditions, ailments, and diseases. In this work, we present the HCT Disc, a centrifugal microdevice fabricated by a Print, Cut and Laminate (PCL) method to generate a 12-sample HCT device from materials costing <0.5 USD (polyester and toner or PeT). Following introduction from a drop of blood (finger stick), whole blood metering and cell sedimentation are controlled by centrifugal force, only requiring a CD player motor as external hardware and, ultimately, a cell phone for detection. The sedimented volume from patient blood in the HCT Disc was analyzed using a conventional scanner/custom algorithm for analysis of the image to determine a hematocrit value, and these were compared to values generated in a clinical laboratory, which correlated well. To enhance portability and assure simplicity of the HCT measurement, values from image analysis by a cell phone using a custom application was compared to the scanner. Fifteen samples were analyzed with cell phone image analysis system and were found to be within 4% of the HCT values determined in the clinical lab. We demonstrate the feasibility of the PeT device for HCT measurement, and highlight its uniquely low cost (<0.5 USD), speed (sample-to-answer <8 min), multiplexability (12 samples), low volume whole blood requirement (<3 μL), rotation speeds (<4000 rpm) needed for effective measurement as well as the direct finger-to-chip sample loading capability. - Highlights: • A 12-sample hematocrit device was developed from polyester-toner materials. • The device can analyze a patient's hematocrit within 8 min from 3 μL of blood. • Cell phone image analysis is used to correctly determine clinical hematocrits.

  11. Analysis of Macular Drusen and Blood Test Results in 945 Macaca fascicularis.

    Directory of Open Access Journals (Sweden)

    Koji M Nishiguchi

    Full Text Available Age-dependent formation of macular drusen caused by the focal accumulation of extracellular deposits beneath the retinal pigment epithelium precede the development of age-related macular degeneration (AMD, one of the leading causes of blindness worldwide. It is established that inflammation contributes to the pathogenesis of drusen and AMD. However, development of a preemptive therapeutic strategy targeting macular drusen and AMD has been impeded by the lack of relevant animal models because most laboratory animals lack macula, an anatomic feature present only in humans and a subset of monkeys. Reportedly, macular drusen and macular degeneration develop in monkeys in an age-dependent manner. In this study, we analyzed blood test results from 945 Macaca fascicularis, 317 with and 628 without drusen. First, a trend test for drusen frequency (the Cochran-Armitage test was applied to the quartile data for each parameter. We selected variables with an increasing or decreasing trend with higher quartiles at P < 0.05, to which multivariate logistic regression analysis was applied. This revealed a positive association of age (odds ratio [OR]: 1.10 per year, 95% confidence interval [CI]: 1.07-1.12 and white blood cell count (OR: 1.01 per 1 × 103/μl, 95% CI: 1.00-1.01 with drusen. When the monkeys were divided by age, the association between drusen and white blood cell count was only evident in younger monkeys (OR: 1.01 per 1 × 103/μl, 95% CI: 1.00-1.02. In conclusion, age and white blood cell count may be associated with drusen development in M. fascicularis. Systemic inflammation may contribute to drusen formation in monkeys.

  12. The cost of post-operative shed blood salvage after total knee arthroplasty: an analysis of 1,093 consecutive procedures

    Science.gov (United States)

    Muñoz, Manuel; Ariza, Daniel; Campos, Arturo; Martín-Montañez, Elisa; Pavía, José

    2013-01-01

    Background Requirements for allogeneic red cell transfusion after total knee arthroplasty are still high (20–50%), and salvage and reinfusion of unwashed, filtered post-operative shed blood is an established method for reducing transfusion requirements following this operation. We performed a cost analysis to ascertain whether this alternative is likely to be cost-effective. Materials and methods Data from 1,093 consecutive primary total knee arthroplasties, managed with (reinfusion group, n=763) or without reinfusion of unwashed salvaged blood (control group, n=330), were retrospectively reviewed. The costs of low-vacuum drains, shed blood collection canisters (Bellovac ABT®, Wellspect HealthCare and ConstaVac CBC II®, Stryker), shed blood reinfusion, acquisition and transfusion of allogeneic red cell concentrate, haemoglobin measurements, and prolonged length of hospital stay were used for the blood management cost analysis. Results Patients in the reinfusion group received 152±64 mL of red blood cells from postoperatively salvaged blood, without clinically relevant incidents, and showed a lower allogeneic transfusion rate (24.5% vs 8.5%, for the control and reinfusion groups, respectively; p =0.001). There were no differences in post-operative infection rates. Patients receiving allogeneic transfusions stayed in hospital longer (+1.9 days [95% CI: 1.2 to 2.6]). As reinfusion of unwashed salvaged blood reduced the allogeneic transfusion rate, both reinfusion systems may provide net savings in different cost scenarios (€ 4.6 to € 106/patient for Bellovac ABT, and € −51.9 to € 49.9/patient for ConstaVac CBCII). Discussion Return of unwashed salvaged blood after total knee arthroplasty seems to save costs in patients with pre-operative haemoglobin between 12 and 15 g/dL. It is not cost-saving in patients with a pre-operative haemoglobin >15 g/dL, whereas in those with a pre-operative haemoglobin cost-saving, its efficacy could be increased by

  13. Neutron activation analysis of some trace elements (selenium, chromium, cobalt and nickel) in the blood of vitiligo patients

    International Nuclear Information System (INIS)

    Teherani, D.K.

    1986-01-01

    Samples of full blood of vitiligo patients and those of control persons were analyzed for Se, Cr, Co and Ni contents by neutron activation analysis. The concentrations are reported in ppm/dry weight. The results showed that the Se and Co levels were significantly higher in the blood of vitiligo patients while the increase of Cr and Ni was not significant as compared to the controls. (author)

  14. Biomarker Analysis of Stored Blood Products: Emphasis on Pre-Analytical Issues

    Science.gov (United States)

    Delobel, Julien; Rubin, Olivier; Prudent, Michel; Crettaz, David; Tissot, Jean-Daniel; Lion, Niels

    2010-01-01

    Millions of blood products are transfused every year; many lives are thus directly concerned by transfusion. The three main labile blood products used in transfusion are erythrocyte concentrates, platelet concentrates and fresh frozen plasma. Each of these products has to be stored according to its particular components. However, during storage, modifications or degradation of those components may occur, and are known as storage lesions. Thus, biomarker discovery of in vivo blood aging as well as in vitro labile blood products storage lesions is of high interest for the transfusion medicine community. Pre-analytical issues are of major importance in analyzing the various blood products during storage conditions as well as according to various protocols that are currently used in blood banks for their preparations. This paper will review key elements that have to be taken into account in the context of proteomic-based biomarker discovery applied to blood banking. PMID:21151459

  15. Thematic analysis of tiles painted by blood and marrow transplant patients during treatment.

    Science.gov (United States)

    Mische Lawson, L; Chau, J; Schoel, A

    2016-11-01

    The majority of research on understanding the illness focuses on analysing the written or verbal content. Thematic analysis of images is a novel qualitative approach that can enhance knowledge of the experience of illness. This study used thematic analysis to examine 171 tiles painted by patients through the Tiles of Hope programme in an outpatient blood and marrow transplant unit. Major themes identified in this study were Faith, Hope, Positive Attitude, Nature and Social Support. These themes provided a better understanding of patients' perceptions in relation to their experience with illness through the art-making process. © 2015 John Wiley & Sons Ltd.

  16. The efficacy of bipolar sealer on blood loss in spine surgery: a meta-analysis.

    Science.gov (United States)

    Lan, Tao; Hu, Shi-Yu; Yang, Xin-Jian; Chen, Yang; Qiu, Yi-Yan; Guo, Wei-Zhuang; Lin, Jian-Ze; Ren, Kai

    2017-07-01

    The purpose of this meta-analysis of randomized controlled trials (RCTs) and non-RCTs was to gather data to evaluate the efficacy and safety of bipolar sealer versus standard electrocautery in the management of spinal disease. The electronic databases including Embase, PubMed and Cochrane library were searched to identify relevant studies published from the time of the establishment of these databases up to January 2017. The primary outcomes were total blood loss, requirement of transfusion (rate and amount), and operation time. The secondary outcomes were length of hospital stay and postoperative wound infection. Data analysis was conducted with RevMan 5.3 software. A total of five studies involving 500 patients (261 patients in the BS group and 239 in the control group) were included in the meta-analysis. The pooled results revealed that application of bipolar sealer could decrease the total blood loss in spine surgery [WMD = -467.49, 95% CI (685.47 to -249.51); p SMD = -0.36, 95% CI (-0.60 to -0.13), p infection [OR = 0.88, 95% CI (0.31-2.48), p = 0.81; I 2  = 0.0%] between both groups. The available evidence suggests that bipolar sealer is superior to standard electrocautery with less blood loss, shorter operation time and less transfusion requirement. There is no significant difference between both groups regarding length of hospitalization and wound infection. Hence, bipolar sealer is recommended in spine surgery. Because of the limitation of our study, more well-designed RCTs with large sample are required to provide further evidence of safety and efficacy between bipolar sealer and standard electrocautery in the treatment of spinal disease.

  17. High-resolution melting (HRM) analysis as a feasible method for detecting spinal muscular atrophy via dried blood spots.

    Science.gov (United States)

    Er, Tze-Kiong; Kan, Tzu-Min; Su, Yu-Fa; Liu, Ta-Chih; Chang, Jan-Gowth; Hung, Shih-Ya; Jong, Yuh-Jyh

    2012-11-12

    Spinal muscular atrophy (SMA) is a neurodegenerative disease with the leading genetic cause of infant mortality. More than 95% of patients with SMA have a homozygous disruption in the survival motor neuron1 (SMN1) gene, caused by mutation, deletion, or rearrangement. Recently, treatment in humans in the immediate postnatal period, prior to the development of weakness or very early in the course of the disease, may be effective. Therefore, our objective was to establish a feasible method for SMA screening. High-resolution melting (HRM) analysis is rapidly becoming the most important mutation-scanning methodology that allows mutation scanning and genotyping without the need for costly labeled oligonucleotides. In the current study, we aim to develop a method for identifying the substitution of single nucleotide in SMN1 exon 7 (c.840C>T) by HRM analysis. Genomic DNA was extracted from peripheral blood samples and dried blood spots obtained from 30 patients with SMA and 30 normal individuals. All results were previously confirmed by denaturing high-performance liquid chromatography (DHPLC). In order to identify the substitution of single nucleotide in SMN1 exon 7 (c.840C>T) by HRM analysis, a primer set was used in HRM analysis. At first, we failed to identify the substitution of single nucleotide in SMN1 exon 7 (c.840C>T) by HRM analysis because the homozygous CC and homozygous TT cannot be distinguished by HRM analysis. Therefore, all samples were mixed with a known SMN1/SMN2 copy number (SMN1/SMN2=0:3), which we may call driver. This strategy is used to differentiate between homozygous CC and homozygous TT. After mixing with driver, the melting profile of homozygous CC becomes heteroduplex; however, the homozygous TT remains the same in the normalized and temperature-shifted difference plots. HRM analysis can be successfully applied to screen SMA via DNA obtained from whole blood and dried blood spots. We strongly believe that HRM analysis, a high-throughput method

  18. Analysis of blood spots for polyfluoroalkyl chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Kayoko; Wanigatunga, Amal A.; Needham, Larry L. [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA (United States); Calafat, Antonia M., E-mail: acalafat@cdc.gov [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA (United States)

    2009-12-10

    Polyfluoroalkyl chemicals (PFCs) have been detected in humans, in the environment, and in ecosystems around the world. The potential for developmental and reproductive toxicities of some PFCs is of concern especially to children's health. In the United States, a sample of a baby's blood, called a 'dried blood spot' (DBS), is obtained from a heel stick within 48 h of a child's birth. DBS could be useful for assessing prenatal exposure to PFCs. We developed a method based on online solid phase extraction coupled with high performance liquid chromatography-isotope dilution tandem mass spectrometry for measuring four PFCs in DBS, perfluorooctane sulfonate (PFOS), perfluorohexane sulfonate, perfluorooctanoate (PFOA), and perfluorononanoate. The analytical limits of detection using one whole DBS ({approx}75 {mu}L of blood) were <0.5 ng mL{sup -1}. To validate the method, we analyzed 98 DBS collected in May 2007 in the United States. PFOS and PFOA were detected in all DBS at concentrations in the low ng mL{sup -1} range. These data suggest that DBS may be a suitable matrix for assessing perinatal exposure to PFCs, but additional information related to sampling and specimen storage is needed to demonstrate the utility of these measures for assessing exposure.

  19. Investigating Functional Extension of Optical Coherence Tomography for Spectroscopic Analysis of Blood Oxygen Saturation

    Science.gov (United States)

    Chen, Siyu

    Over the past two decades, optical coherence tomography (OCT) has been successfully applied to various fields of biomedical researching and clinical studies, including cardiology, urology, dermatology, dentistry, oncology, and most successfully, ophthalmology. This dissertation seeks to extend the current OCT practice, which is still largely morphology-based, into a new dimension, functional analysis of metabolic activities in vivo. More specifically, the investigation is focused on retrieving blood oxygen saturation (sO2) using intrinsic hemoglobin optical absorption contrast. Most mammalian cells rely on aerobic respiration to support cellular function, which means they consume oxygen to create adenosine triphosphate (ATP). Metabolic rate of oxygen (MRO2), a key hemodynamic parameter, characterizes how much oxygen is consumed during a given period of time, reflecting the metabolic activity of the target tissue. For example, retinal neurons are highly active and almost entirely rely on the moment-to-moment oxygen supply from retinal circulations. Thus, variation in MRO2 reveals the instantaneous activity of these neurons, shedding light on the physiological and pathophysiological change of cellular functions. Eventually, measuring MRO2 can potentially provide a biomarker for early-stage disease diagnosis, and serve as one benchmark for evaluating effectiveness of medical intervention during disease management. Essential in calculating MRO2, blood sO2 measurements using spectroscopic OCT analysis has been attempted as early as 2003. OCT is intrinsically sensitive to the blood optical absorption spectrum due to its wide-band illumination and detection scheme relying on back-scattered photon. However, accurate retrieval of blood sO2 using conventional near infrared (NIR) OCT systems in vivo has remained challenging. It was not until the development of OCT systems using visible light illumination (vis-OCT) when accurate measurement of blood sO2 was reported in live

  20. Two-Dimensional Computational Flow Analysis and Frictional Characteristics Model for Red Blood Cell under Inclined Centrifuge Microscopy

    Science.gov (United States)

    Funamoto, Kenichi; Hayase, Toshiyuki; Shirai, Atsushi

    Simplified two-dimensional flow analysis is performed in order to simulate frictional characteristics measurement of red blood cells moving on a glass plate in a medium with an inclined centrifuge microscope. Computation under various conditions reveals the influences of parameters on lift, drag, and moment acting on a red blood cell. Among these forces, lift appears only when the cell is longitudinally asymmetric. By considering the balance of forces, the frictional characteristics of the red blood cell are modeled as the sum of Coulomb friction and viscous drag. The model describes the possibility that the red blood cell deforms to expand in the front side in response to the inclined centrifugal force. When velocity exceeds some critical value, the lift overcomes the normal centrifugal force component, and the thickness of the plasma layer between the cell and the glass plate increases from the initial value of the plasma protein thickness.

  1. Low Temperature Irradiation Applied to Neutron Activation Analysis of Mercury In Human Whole Blood

    Energy Technology Data Exchange (ETDEWEB)

    Brune, D

    1966-02-15

    The distribution of mercury in human whole blood has been studied by means of neutron activation analysis. During the irradiation procedure the samples were kept at low temperature by freezing them in a cooling device in order to prevent interferences caused by volatilization and contamination. The mercury activity was separated by means of distillation and ion exchange techniques.

  2. Low Temperature Irradiation Applied to Neutron Activation Analysis of Mercury In Human Whole Blood

    International Nuclear Information System (INIS)

    Brune, D.

    1966-02-01

    The distribution of mercury in human whole blood has been studied by means of neutron activation analysis. During the irradiation procedure the samples were kept at low temperature by freezing them in a cooling device in order to prevent interferences caused by volatilization and contamination. The mercury activity was separated by means of distillation and ion exchange techniques

  3. Heavy metals analysis in blood by the X-ray fluorescence method

    International Nuclear Information System (INIS)

    Perez Novara, Ana Ma.

    1988-05-01

    The analytical procedure for determination of heavy metals in blood is described. Blood was taken from active smelter workers, samples were stored in special flasks at 2 grades C. After freeze drying, dried samples was analyzed using X-ray fluorescence, sources excited: Pu-238 and Cd-109 was used. Br in Pb interferences were corrected. The agreement of the results with values in similar workers is satisfactory Median Pb level was 42.6 micro grams/100 ml (total blood), Cu was less 2.5 micro grams/g (dry blood) and Zn was 11 micro grams/g (dry blood). (author)

  4. Epsilon aminocaproic acid reduces blood transfusion and improves the coagulation test after pediatric open-heart surgery: a meta-analysis of 5 clinical trials.

    Science.gov (United States)

    Lu, Jun; Meng, Haoyu; Meng, Zhaoyi; Sun, Ying; Pribis, John P; Zhu, Chunyan; Li, Quan

    2015-01-01

    Excessive postoperative blood loss after cardiopulmonary bypass is a common problem, especially in patients suffering from congenital heart diseases. The efficacy of epsilon aminocaproic acid (EACA) as a prophylactic treatment for postoperative bleeding after pediatric open-heart surgery has not been determined. This meta-analysis investigates the efficacy of EACA in the minimization of bleeding and blood transfusion and the maintenance of coagulation tests after pediatric open-heart surgery. A comprehensive literature search was performed to identify all randomized clinical trials on the subject. PubMed, Embase, the Cochrane Library, and the Chinese Medical Journal Network were screened. The primary outcome used for the analysis was postoperative blood loss. Secondary outcomes included postoperative blood transfusion, re-exploration rate and postoperative coagulation tests. The mean difference (MD) and risk ratio (RR) with 95% confidence intervals (CI) were used as summary statistics. Five trials were included in this meta-analysis of 515 patients. Prophylactic EACA was associated with a reduction in postoperative blood loss, but this difference did not reach statistical significance (MD: -7.08; 95% CI: -16.11 to 1.95; P = 0.12). Patients treated with EACA received fewer postoperative blood transfusions, including packed red blood cells (MD: -8.36; 95% CI: -12.63 to -4.09; P = 0.0001), fresh frozen plasma (MD: -3.85; 95% CI: -5.63 to -2.08; P open-heart surgery. Prophylactic EACA minimizes postoperative blood transfusion and helps maintain coagulation in pediatric patients undergoing open-heart surgery. Therefore, the results of this study indicate that adjunctive EACA is a good choice for the prevention of postoperative blood transfusion following pediatric cardiac surgery.

  5. Diet, blood pressure, and multicollinearity.

    Science.gov (United States)

    Reed, D; McGee, D; Yano, K; Hankin, J

    1985-01-01

    Recent reports of an inverse association between dietary calcium intake and hypertension stimulated this analysis of the relationship of blood pressure to more than 20 dietary factors among a group of 8000 Japanese men in Hawaii. Reported intakes of potassium, calcium, protein, and milk were all inversely associated with blood pressure levels when examined one at a time while controlling for other risk factors. Alcohol intake was directly associated with blood pressure, and was treated as a confounding variable in the analysis. The association of potassium intake with blood pressure was relatively stronger than the associations for other nutrients, but the intake of potassium was so highly correlated with intakes of calcium, milk, and protein that it was not statistically possible to identify the independent association of potassium and blood pressure. Calcium intake was strongly correlated with milk and potassium intakes, and only calcium from dairy sources was associated with blood pressure. These data thus indicate that several dietary factors are inversely related to blood pressure levels independently of other risk factors such as age, body mass, and alcohol intake. The high degree of intercorrelation (multicollinearity) among these dietary factors, however, indicates that the independent role of any specific nutrient cannot be conclusively separated from the possible effects of other nutrients in this type of study.

  6. BLOOD DOPING AND RISKS

    Directory of Open Access Journals (Sweden)

    Goran Vasić

    2015-05-01

    Full Text Available Doping is the way in which athletes misuse of chemicals and other types of medical interventions (eg, blood replacement, try to get ahead in the results of other athletes or their performance at the expense of their own health. The aim of this work is the analysis of blood doping and the display of negative consequences that this way of increasing capabilities brings. Method: The methodological work is done descriptively. Results: Even in 1972 at the Stockholm Institute for gymnastics and sport, first Dr. Bjorn Ekblom started having blood doping. Taken from the blood, athletes through centifuge separating red blood cells from blood plasma, which is after a month of storage in the fridge, every athlete back into the bloodstream. Tests aerobic capacity thereafter showed that the concerned athletes can run longer on average for 25% of the treadmill than before. Discussion: Blood doping carries with it serious risks, excessive amount of red cells “thickens the blood,” increased hematocrit, which reduces the heart’s ability to pump blood to the periphery. All this makes it difficult for blood to flow through blood vessels, and there is a great danger that comes to a halt in the circulation, which can cause cardiac arrest, stroke, pulmonary edema, and other complications that can be fatal.

  7. Pleomorphic Structures in Human Blood Are Red Blood Cell-Derived Microparticles, Not Bacteria.

    Science.gov (United States)

    Mitchell, Adam J; Gray, Warren D; Schroeder, Max; Yi, Hong; Taylor, Jeannette V; Dillard, Rebecca S; Ke, Zunlong; Wright, Elizabeth R; Stephens, David; Roback, John D; Searles, Charles D

    2016-01-01

    Red blood cell (RBC) transfusions are a common, life-saving therapy for many patients, but they have also been associated with poor clinical outcomes. We identified unusual, pleomorphic structures in human RBC transfusion units by negative-stain electron microscopy that appeared identical to those previously reported to be bacteria in healthy human blood samples. The presence of viable, replicating bacteria in stored blood could explain poor outcomes in transfusion recipients and have major implications for transfusion medicine. Here, we investigated the possibility that these structures were bacteria. Flow cytometry, miRNA analysis, protein analysis, and additional electron microscopy studies strongly indicated that the pleomorphic structures in the supernatant of stored RBCs were RBC-derived microparticles (RMPs). Bacterial 16S rDNA PCR amplified from these samples were sequenced and was found to be highly similar to species that are known to commonly contaminate laboratory reagents. These studies suggest that pleomorphic structures identified in human blood are RMPs and not bacteria, and they provide an example in which laboratory contaminants may can mislead investigators.

  8. Performance Analysis of Fuzzy-PID Controller for Blood Glucose Regulation in Type-1 Diabetic Patients.

    Science.gov (United States)

    Yadav, Jyoti; Rani, Asha; Singh, Vijander

    2016-12-01

    This paper presents Fuzzy-PID (FPID) control scheme for a blood glucose control of type 1 diabetic subjects. A new metaheuristic Cuckoo Search Algorithm (CSA) is utilized to optimize the gains of FPID controller. CSA provides fast convergence and is capable of handling global optimization of continuous nonlinear systems. The proposed controller is an amalgamation of fuzzy logic and optimization which may provide an efficient solution for complex problems like blood glucose control. The task is to maintain normal glucose levels in the shortest possible time with minimum insulin dose. The glucose control is achieved by tuning the PID (Proportional Integral Derivative) and FPID controller with the help of Genetic Algorithm and CSA for comparative analysis. The designed controllers are tested on Bergman minimal model to control the blood glucose level in the facets of parameter uncertainties, meal disturbances and sensor noise. The results reveal that the performance of CSA-FPID controller is superior as compared to other designed controllers.

  9. Multidimensional protein fractionation of blood proteins coupled to data-independent nanoLC-MS/MS analysis.

    Science.gov (United States)

    Levin, Yishai; Jaros, Julian A J; Schwarz, Emanuel; Bahn, Sabine

    2010-01-03

    In order to exploit human blood as a source of protein disease biomarkers, robust analytical methods are needed to overcome the inherent molecular complexity of this bio-fluid. We present the coupling of label-free SAX chromatography and IMAC to a data-independent nanoLC-MS/MS (nanoLC-MS(E)) platform for analysis of blood plasma and serum proteins. The methods were evaluated using protein standards added at different concentrations to two groups of samples. The results demonstrate that both techniques enable accurate protein quantitation using low sample volumes and a minimal number of fractions. Combining both methods, 883 unique proteins were identified, of which 423 proteins showed high reproducibility. The two approaches resulted in identification of unique molecular signatures with an overlap of approximately 30%, thus providing complimentary information on sub-proteomes. These methods are potentially useful for systems biology, biomarker discovery, and investigation of phosphoproteins in blood. (c) 2009 Elsevier B.V. All rights reserved.

  10. A Systematic Review and Meta-Analysis of the Clinical Appropriateness of Blood Transfusion in China.

    Science.gov (United States)

    Zhu, Changtai; Gao, Yulu; Li, Zhiqiang; Li, Qinyun; Gao, Zongshuai; Liao, Yanqiu; Deng, Zhifeng

    2015-12-01

    The issue of the clinical appropriateness of blood transfusion has become a focus of transfusion medicine worldwide. In China, irrational uses of blood have often been reported in recent years. However, to date there lacks a systematic review of the rational uses of blood. This study aimed to determine the clinical appropriateness of blood transfusion in China. We searched PubMed, Web of Science, the Cochrane Library, China National Knowledge Infrastructure (CNKI), China Science and Technology Journal Database, WanFang Database, and Chinese BioMedical Literature Database, and the retrieval cut-off date was June 31, 2015. SPSS 17.0 and MetaAnalyst 3.13 were employed as the statistics tools in this review. A pooled rate of clinical inappropriateness of transfusion was analyzed by DerSimonian-Laird method. In this study, a total of 39 observational studies were included, which related to 75,132 cases of blood transfusion. According to the meta-analysis results, the overall incidence of clinical inappropriateness of transfusion in China was estimated to be 37.3% (95% confidence interval [CI] [32.1, 42.8]). The subgroup analyses revealed that the pooled rates of clinical inappropriateness of transfusion of plasma, red blood cells (RBCs), cryoprecipitate, and platelets were 56.3% (95% CI [45.8, 66.2]), 30.9% (95% CI [27.1, 35.0]), 25.2% (95% CI [13.2, 42.7]), and 14.1% (95% CI [8.8, 21.9]), respectively. However, the pooled incidence of inappropriateness of transfusion in operative departments was 47.5% (95% CI [36.8, 58.3]), which was significantly higher than that in nonoperative departments, 25.8% (95% CI [18.7, 34.4], P  0.05). In conclusion, China has suffered from a disadvantage in the clinical appropriateness of blood transfusion, especially in plasma and RBC use. In future, comprehensive measures should be implemented in order to improve the clinical appropriateness of blood transfusion.

  11. Can we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?

    Directory of Open Access Journals (Sweden)

    Pedram Niknafs

    2015-05-01

    Full Text Available Neonates with respiratory distress syndrome (RDS, who are treated according to INSURE protocol; require arterial blood gas (ABG analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS, 7.2% were found to have one or more of the followings: acidosis, hypercapnia, or hypoxemia. We found that pulse oximetry in the detection of hyperoxemia had a good validity to appropriately manage patients without blood gas analysis. However, the validity of pulse oximetry was not good enough to detect acidosis, hypercapnia, and hypoxemia.

  12. Blood plasma sample preparation method to determine thyroid hormone-disrupting compounds in Effect-Directed Analysis

    NARCIS (Netherlands)

    Simon, E.; Bytingsvik, J.; Jonker, W.; Leonards, P.E.G.; de Boer, J.; Jenssen, B.M.; Lie, E.; Aars, J.; Hamers, T.H.M.; Lamoree, M.H.

    2011-01-01

    A sample preparation method combining solid-phase extraction (SPE) and liquid-liquid extraction (LLE) was developed to be used in Effect-Directed Analysis (EDA) of blood plasma. Until now such a method was not available. It can be used for extraction of a broad range of thyroid hormone

  13. Donor vigilance data of a blood transfusion service: A multicenter analysis.

    Science.gov (United States)

    Burkhardt, T; Dimanski, B; Karl, R; Sievert, U; Karl, A; Hübler, C; Tonn, T; Sopvinik, I; Ertl, H; Moog, R

    2015-10-01

    Donor vigilance is an important part of the quality management system of blood transfusion services. The evaluation of donor side effects helps to improve the donation process and donor compliance. The aim of the present study was to evaluate donor vigilance data in whole blood and plasmapheresis donors of a blood donor service. Donors fulfilling current national and European eligibility criteria underwent whole blood and plasmapheresis donation (PCS and MCS+ (Haemonetics, Braintree, USA), A 200 (Fenwal, Round Lake, USA). Whole blood was collected at fixed and mobile sites while plasmaphereses were performed at 8 plasma centers. From 2011 to 2013 donor information was provided for gender, age, body weight, height, first and repeat donation. Donors were monitored for venipuncture and circulatory associated side effects. The total incidences of adverse events were 5004 (0.56%) in repeat donors and 2111 (2.78%) in first time donors for whole blood donation and 3323 (1.01%) and 514 (7.96%) for plasmaphereses, respectively. Circulatory associated events were 2679 (0.30%) for whole blood donation and 1624 (0.49%) for plasmaphereses. Our donor vigilance data of a blood transfusion service show that whole blood and plasmapheresis are safe with low incidences of adverse events. Repeat donation and age are predictors for low rates of adverse events. On the other hand, first time donation and female gender were associated with higher incidences of adverse events. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Meta-analysis of peripheral blood gene expression modules for COPD phenotypes.

    Directory of Open Access Journals (Sweden)

    Dominik Reinhold

    Full Text Available Chronic obstructive pulmonary disease (COPD occurs typically in current or former smokers, but only a minority of people with smoking history develops the disease. Besides environmental factors, genetics is an important risk factor for COPD. However, the relationship between genetics, environment and phenotypes is not well understood. Sample sizes for genome-wide expression studies based on lung tissue have been small due to the invasive nature of sample collection. Increasing evidence for the systemic nature of the disease makes blood a good alternative source to study the disease, but there have also been few large-scale blood genomic studies in COPD. Due to the complexity and heterogeneity of COPD, examining groups of interacting genes may have more relevance than identifying individual genes. Therefore, we used Weighted Gene Co-expression Network Analysis to find groups of genes (modules that are highly connected. However, module definitions may vary between individual data sets. To alleviate this problem, we used a consensus module definition based on two cohorts, COPDGene and ECLIPSE. We studied the relationship between the consensus modules and COPD phenotypes airflow obstruction and emphysema. We also used these consensus module definitions on an independent cohort (TESRA and performed a meta analysis involving all data sets. We found several modules that are associated with COPD phenotypes, are enriched in functional categories and are overrepresented for cell-type specific genes. Of the 14 consensus modules, three were strongly associated with airflow obstruction (meta p ≤ 0.0002, and two had some association with emphysema (meta p ≤ 0.06; some associations were stronger in the case-control cohorts, and others in the cases-only subcohorts. Gene Ontology terms that were overrepresented included "immune response" and "defense response." The cell types whose type-specific genes were overrepresented in modules (p < 0.05 included

  15. Home blood pressure monitoring, secure electronic messaging and medication intensification for improving hypertension control: a mediation analysis.

    Science.gov (United States)

    Ralston, J D; Cook, A J; Anderson, M L; Catz, S L; Fishman, P A; Carlson, J; Johnson, R; Green, B B

    2014-01-01

    We evaluated the role of home monitoring, communication with pharmacists, medication intensification, medication adherence and lifestyle factors in contributing to the effectiveness of an intervention to improve blood pressure control in patients with uncontrolled essential hypertension. We performed a mediation analysis of a published randomized trial based on the Chronic Care Model delivered over a secure patient website from June 2005 to December 2007. Study arms analyzed included usual care with a home blood pressure monitor and usual care with home blood pressure monitor and web-based pharmacist care. Mediator measures included secure messaging and telephone encounters; home blood pressure monitoring; medications intensification and adherence and lifestyle factors. Overall fidelity to the Chronic Care Model was assessed with the Patient Assessment of Chronic Care (PACIC) instrument. The primary outcome was percent of participants with blood pressure (BP) <140/90 mm Hg. At 12 months follow-up, patients in the web-based pharmacist care group were more likely to have BP <140/90 mm Hg (55%) compared to patients in the group with home blood pressure monitors only (37%) (p = 0.001). Home blood pressure monitoring accounted for 30.3% of the intervention effect, secure electronic messaging accounted for 96%, and medication intensification for 29.3%. Medication adherence and self-report of fruit and vegetable intake and weight change were not different between the two study groups. The PACIC score accounted for 22.0 % of the main intervention effect. The effect of web-based pharmacist care on improved blood pressure control was explained in part through a combination of home blood pressure monitoring, secure messaging, and antihypertensive medication intensification.

  16. Triggers of blood transfusion in percutaneous nephrolithotomy

    International Nuclear Information System (INIS)

    Zehri, A.K.; Biyabani, S.R.; Siddiqui, K.M.; Memon, A.

    2011-01-01

    To determine the triggers of blood transfusion in patients undergoing percutaneous nephrolithotomy (PCNL). The percutaneous surgery database was retrospectively reviewed to identify patients with postoperative haemorrhage and need for blood transfusion. Blood loss was estimated by the postoperative drop in haemoglobin factored by the quantity of any blood transfusion. Various patients and procedure-related factors were assessed for association with total blood loss or blood transfusion requirement using stepwise univariate, forward multivariate regression analysis. A total of 326 procedures were performed in 316 patients. Two hundred and thirty two procedures were included in the study. There were 167 males and 65 females. The mean age was 41+14 years. The mean haemoglobin drop was 1.68 +1.3 gm/dL. The overall blood transfusion rate was 14.2%. Stepwise multivariate regression analysis showed that female gender (p = 0.003), staghorn stone (p = 0.023), stone fragmentation with ultrasound (p = 0.054) and chronic renal failure (p = 0.001) were significantly predictive of the need for blood transfusion. Chronic renal failure, female gender, presence of staghorn calculi and stone fragmentation using ultrasonic device were predictive of blood transfusion in this cohort of patients. (author)

  17. HIV and the Blood Supply: An Analysis of Crisis Decisionmaking

    National Research Council Canada - National Science Library

    Leveton, Lauren B; Sox, Harold C. Jr; Stoto, Michael A

    .... Because little reliable information existed at the time AIDS first began showing up in hemophiliacs and in others who had received transfusions, experts disagreed about whether blood and blood...

  18. Impact of blood sampling in very preterm infants

    DEFF Research Database (Denmark)

    Madsen, L P; Rasmussen, M K; Bjerregaard, L L

    2000-01-01

    ; the groups were then subdivided into critically ill or not. Diagnostic blood sampling and blood transfusion events were recorded. In total, 1905 blood samples (5,253 analysis) were performed, corresponding to 0.7 samples (1.9 analysis) per day per infant. The highest frequencies were found during the first....../kg. For the extremely preterm infants a significant correlation between sampled and transfused blood volume was found (mean 37.1 and 33.3 ml/kg, respectively, r = + 0.71, p = 0.0003). The most frequently requested analyses were glucose, sodium and potassium. Few blood gas analyses were requested (1.9/ infant). No blood...... losses attributable to excessive generous sampling were detected. The results show an acceptable low frequency of sampling and transfusion events for infants of GA 28-32 weeks. The study emphasizes the necessity of thorough reflection and monitoring of blood losses when ordering blood sampling...

  19. An Analysis of and Recommendations for the Peruvian Blood Collection and Transfusion System.

    Science.gov (United States)

    George, Paul E; Vidal, Julio; Garcia, Patricia J

    2016-05-01

    Peru experienced a crisis in its blood collection and supply system in the mid-2000s, as contaminated blood led to several transfusion-transmitted infections (TTI), occurring in the backdrop of extremely low voluntary donation rates and a national blood supply shortage. Thus, the Peruvian Ministry of Health (MINSA) implemented a national investigation on the safety and quality of the Peruvian blood collection/transfusion network. Every Peruvian blood bank was evaluated by MINSA from 2007-2008. These evaluations consisted of an update of the national registry of blood banks and visits to each blood bank from MINSA oversight teams. Information was collected on the condition of the blood bank personnel, equipment, supplies, and practices. Further, previously-collected blood at each blood bank was randomly selected and screened for TTI-causing pathogens. Uncovered in this investigation was a fragmented, under-equipped, and poorly-staffed blood collection and transfusion network, consisting of 241 independent blood banks and resulting in suboptimal allocation of resources. Further, blood with evidence of TTI-causing pathogens (including Hepatitis B, Hepatitis C, and syphilis) and set for transfusion was discovered at three separate blood banks as part of the random screening process. Using the successful reorganizations of national blood supply systems in other Latin American countries as examples, Peru would be well-served to form large, high-volume, regional blood collection and transfusion centers, responsible for blood collection and screening for the entire country. The small, separate blood banks would then be transformed into a network of blood transfusion centers, not responsible for blood collection. This reorganization would allow Peru to better utilize its resources, standardize the blood collection and transfusion process, and increase voluntary donation, resulting in a safer, more abundant national blood product.

  20. Do autologous blood transfusion systems reduce allogeneic blood transfusion in total knee arthroplasty?

    Science.gov (United States)

    Pawaskar, Aditya; Salunke, Abhijeet Ashok; Kekatpure, Aashay; Chen, Yongsheng; Nambi, G I; Tan, Junhao; Sonawane, Dhiraj; Pathak, Subodhkumar

    2017-09-01

    To study whether autologus blood transfusion systems reduce the requirement of allogneic blood transfusion in patients undergoing total knee arthroplasty. A comprehensive search of the published literature with PubMed, Scopus and Science direct database was performed. The following search terms were used: (total knee replacement) OR (total knee arthroplasty) OR (TKA) AND (blood transfusion) OR (autologous transfusion) OR (autologous transfusion system). Using search syntax, a total of 748 search results were obtained (79 from PubMed, 586 from Science direct and 83 from Scopus). Twenty-one randomized control trials were included for this meta-analysis. The allogenic transfusion rate in autologus blood transfusion (study) group was significantly lower than the control group (28.4 and 53.5 %, respectively) (p value 0.0001, Relative risk: 0.5). The median units of allogenic blood transfused in study control group and control group were 0.1 (0.1-3.0) and 1.3 (0.3-2.6), respectively. The median hospital stay in study group was 9 (6.7-15.6) days and control group was 8.7 (6.6-16.7) days. The median cost incurred for blood transfusion per patient in study and control groups was 175 (85.7-260) and 254.7 (235-300) euros, respectively. This meta-analysis demonstrates that the use of auto-transfusion systems is a cost-effective method to reduce the need for and quantity of allogenic transfusion in elective total knee arthroplasty. Level I.

  1. Quantitative Analysis of Therapeutic Drugs in Dried Blood Spot Samples by Paper Spray Mass Spectrometry: An Avenue to Therapeutic Drug Monitoring

    Science.gov (United States)

    Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham

    2011-09-01

    A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.

  2. Miltenberger blood group typing by real-time polymerase chain reaction (qPCR) melting curve analysis in Thai population.

    Science.gov (United States)

    Vongsakulyanon, A; Kitpoka, P; Kunakorn, M; Srikhirin, T

    2015-12-01

    To develop reliable and convenient methods for Miltenberger (Mi(a) ) blood group typing. To apply real-time polymerase chain reaction (qPCR) melting curve analysis to Mi(a) blood group typing. The Mi(a) blood group is the collective set of glycophorin hybrids in the MNS blood group system. Mi(a+) blood is common among East Asians and is also found in the Thai population. Incompatible Mi(a) blood transfusions pose the risk of life-threatening haemolysis; therefore, Mi(a) blood group typing is necessary in ethnicities where the Mi(a) blood group is prevalent. One hundred and forty-three blood samples from Thai blood donors were used in the study. The samples included 50 Mi(a+) samples and 93 Mi(a-) samples, which were defined by serology. The samples were typed by Mi(a) typing qPCR, and 50 Mi(a+) samples were sequenced to identify the Mi(a) subtypes. Mi(a) subtyping qPCR was performed to define GP.Mur. Both Mi(a) typing and Mi(a) subtyping were tested on a conventional PCR platform. The results of Mi(a) typing qPCR were all concordant with serology. Sequencing of the 50 Mi(a+) samples revealed 47 GP.Mur samples and 3 GP.Hop or Bun samples. Mi(a) subtyping qPCR was the supplementary test used to further define GP.Mur from other Mi(a) subtypes. Both Mi(a) typing and Mi(a) subtyping performed well using a conventional PCR platform. Mi(a) typing qPCR correctly identified Mi(a) blood groups in a Thai population with the feasibility of Mi(a) subtype discrimination, and Mi(a) subtyping qPCR was able to further define GP.Mur from other Mi(a) subtypes. © 2015 British Blood Transfusion Society.

  3. Relationship between blood manganese and blood pressure in the Korean general population according to KNHANES 2008

    International Nuclear Information System (INIS)

    Lee, Byung-Kook; Kim, Yangho

    2011-01-01

    Introduction: We present data on the association of manganese (Mn) level with hypertension in a representative sample of the adult Korean population who participated in the Korean National Health and Nutrition Examination Survey (KNHANES) 2008. Methods: This study was based on the data obtained by KNHANES 2008, which was conducted for three years (2007-2009) using a rolling sampling design involving a complex, stratified, multistage, probability-cluster survey of a representative sample of the noninstitutionalized civilian population of South Korea. Results: Multiple regression analysis after controlling for covariates, including gender, age, regional area, education level, smoking, drinking status, hemoglobin, and serum creatinine, showed that the beta coefficients of log blood Mn were 3.514, 1.878, and 2.517 for diastolic blood pressure, and 3.593, 2.449, and 2.440 for systolic blood pressure in female, male, and all participants, respectively. Multiple regression analysis including three other blood metals, lead, mercury, and cadmium, revealed no significant effects of the three metals on blood pressure and showed no effect on the association between blood Mn and blood pressure. In addition, doubling the blood Mn increased the risk of hypertension 1.828, 1.573, and 1.567 fold in women, men, and all participants, respectively, after adjustment for covariates. The addition of blood lead, mercury, and cadmium as covariates did not affect the association between blood Mn and the prevalence of hypertension. Conclusion: Blood Mn level was associated with an increased risk of hypertension in a representative sample of the Korean adult population. - Highlights: → We showed the association of manganese with hypertension in Korean population. → This study was based on the data obtained by KNHANES 2008. → Blood manganese level was associated with an increased risk of hypertension.

  4. Job strain and blood pressure in employed men and women: a pooled analysis of four northern italian population samples.

    Science.gov (United States)

    Cesana, Giancarlo; Sega, Roberto; Ferrario, Marco; Chiodini, Paolo; Corrao, Giovanni; Mancia, Giuseppe

    2003-01-01

    The extent to which psychosocial stress concurs to raise blood pressure is still uncertain. Here the association between job strain and office blood pressure in a pooled analysis of four population samples from northern Italy is assessed. Four surveys assessing prevalence of major coronary risk factors were performed in 1986, 1990, 1991, and 1993 in area "Brianza" (Milan), a World Health Organization-MONItoring cardiovascular disease (WHO-MONICA) Project collaborating center. Ten year age- and gender-stratified independent samples were randomly recruited from the 25- to 64-year-old residents. The methods used to assess coronary risk factors strictly adhered to the MONICA manual, were kept constant, and underwent internal and external quality controls. Job strain was investigated through the administration to employed participants of a questionnaire derived from the Karasek model, assessing job demand/control latitude. Analysis was restricted to 25- to 54-year-old participants, untreated for hypertension (1799 men and 1010 women). Among men, there was a 3 mm Hg increase of systolic blood pressure (pjob categories. This difference was independent from age, education, body mass index, alcohol intake, smoking habits, leisure time physical activity, and survey. No relevant differences among job strain categories were found in women and for diastolic blood pressure in both gender groups. These results carried out on a large population-based sample confirm previous findings obtained adopting ambulatory blood pressure measurements in more restricted samples of population or patients. Further research is needed to clarify the relationship between perceived work stress and blood pressure in women.

  5. Analysis of the Factors Affecting the Interval between Blood Donations Using Log-Normal Hazard Model with Gamma Correlated Frailties.

    Science.gov (United States)

    Tavakol, Najmeh; Kheiri, Soleiman; Sedehi, Morteza

    2016-01-01

    Time to donating blood plays a major role in a regular donor to becoming continues one. The aim of this study was to determine the effective factors on the interval between the blood donations. In a longitudinal study in 2008, 864 samples of first-time donors in Shahrekord Blood Transfusion Center,  capital city of Chaharmahal and Bakhtiari Province, Iran were selected by a systematic sampling and were followed up for five years. Among these samples, a subset of 424 donors who had at least two successful blood donations were chosen for this study and the time intervals between their donations were measured as response variable. Sex, body weight, age, marital status, education, stay and job were recorded as independent variables. Data analysis was performed based on log-normal hazard model with gamma correlated frailty. In this model, the frailties are sum of two independent components assumed a gamma distribution. The analysis was done via Bayesian approach using Markov Chain Monte Carlo algorithm by OpenBUGS. Convergence was checked via Gelman-Rubin criteria using BOA program in R. Age, job and education were significant on chance to donate blood (Pdonation for the higher-aged donors, clericals, workers, free job, students and educated donors were higher and in return, time intervals between their blood donations were shorter. Due to the significance effect of some variables in the log-normal correlated frailty model, it is necessary to plan educational and cultural program to encourage the people with longer inter-donation intervals to donate more frequently.

  6. Analysis of gingival pocket microflora and biochemical blood parameters in dogs suffering from periodontal disease.

    Science.gov (United States)

    Polkowska, Izabela; Sobczyńska-Rak, Aleksandra; Gołyńska, Magdalena

    2014-01-01

    Periodontal diseases in dogs are caused by bacteria colonising the oral cavity. The presence of plaque comprising accumulations of aerobic and anaerobic bacteria leads to the development of periodontitis. Due to the fact that in a large percentage of cases periodontal diseases remain undiagnosed, and consequently untreated, they tend to acquire a chronic character, lead to bacteraemia and negatively impact the health of internal organs. The aim of the present study was to perform a qualitative microbiological analysis of gingival pockets and determine the correlations between selected morphological and biochemical blood parameters and the extent periodontal diseases. Twenty-one dogs treated for periodontal diseases were qualified for the study and subsequently divided into two groups: with 3rd and 4th stage of periodontal disease. Swabs from the patients' gingival pockets were taken for bacteriological testing. Blood was tested for parameters including erythrocyte count, haemoglobin concentration, haematocrit values and leukocyte count. Blood serum was analyzed with respect to the concentrations of alanine transaminase (ALT), aspartate transaminase (AspAT/AST) and urea. The microbiological analysis of gingival pockets indicated the presence of numerous pathogens with a growth tendency in bacterial cultures observed in dogs with advanced-stage periodontal disease. The concentration of biochemical blood markers was significantly higher in dogs with 4th stage of periodontal disease, to compared to the 3rd-stage group. Morphological parameters were not significantly different with the exception of haemoglobin concentration, which was lower in dogs with 4th stage disease. In both groups, elevated leukocyte counts were observed. By conducting a detailed microbiological examination, it is possible to provide a better prognosis, plan adequate treatment and monitor dogs treated for peridontopathy. Copyright © 2014 International Institute of Anticancer Research (Dr. John G

  7. Blood alcohol concentration in drivers of Liege area (Belgium): a 5-year analysis.

    Science.gov (United States)

    Deville, M; Charlier, C

    2015-10-01

    The objective of the study was to describe 'the results of the blood alcohol determinations made on drivers from the Liege area between 2007 and 2012. The results were interpreted according to the sex, to the age, to the circumstances and temporal variation of the test. Statistical analysis was performed using R® software. 2725 determinations were done, mainly after crashes. The mean blood alcohol concentration (BAC) was 1.69 g/L, and 2132 drivers were above the legal threshold. A majority of offenders were men, but the mean BAC did not differ significantly between men and women. A correlation between age and mean BAC can be observed on the positive cases. Lowest and highest mean BACs are observed during the daytime and during the night, respectively, but no significant difference can be observed between the week and the weekend. Finally, no significant difference in BAC was observed over years.

  8. HIV and the Blood Supply: An Analysis of Crisis Decisionmaking

    National Research Council Canada - National Science Library

    Leveton, Lauren B; Sox, Harold C. Jr; Stoto, Michael A

    .... This volume provides a balanced inquiry into the blood safety controversy, which involves private sexual practices, personal tragedy for the victims of HIV/AIDS, and public confidence in America's blood services system...

  9. Cost effectiveness of cord blood versus bone marrow and peripheral blood stem cells

    Directory of Open Access Journals (Sweden)

    Thomas Bart

    2010-10-01

    Full Text Available Thomas BartSwiss Blood Stem Cells, Bern, SwitzerlandAbstract: Umbilical cord blood (CB has become, since its first successful use more than two decades ago, an increasingly important source of blood stem cells. In this light, an overview of current usage of CB in the field of unrelated hematopoietic blood stem cell transplantation (HSCT is given. The three main sources of hematopoietic stem cells: bone marrow (BM, peripheral blood stem cells (PBSC, and cord blood (CB are compared as regards their current quantitative usage in HSCT. A cost analysis of the named three hematopoietic blood stem cell (HSC sources, taking into account various factors, is undertaken. The health economical comparison shows significant differences between CB on the one side, and BM and PBSC on the other. The consequences for the public health side and propositions for a possible health care policy, especially regarding future resource allocation towards the different choices for HSCT products, are discussed. An outlook on the possible future usage of BM, PBSC, and CB and its implications on health systems, donor registries, and CB banks is given.Keywords: health economy, cord blood, hematopoietic stem cell transplantation

  10. Recruitment and retention of blood donors in four Canadian cities: an analysis of the role of community and social networks.

    Science.gov (United States)

    Smith, André; Matthews, Ralph; Fiddler, Jay

    2013-12-01

    This study approaches the decision to donate blood as a dynamic process involving interplay between blood donors' personal motives, donors' social contexts, and the donor recruitment and retention activities of blood collection agencies. Data were gathered from four blood donation clinics using in-depth interviews with Canadian Blood Services employees, donors, and nondonors in 25 organizations participating in Life Link, a donor recruitment program that supports organizations to educate employees about the benefits of blood donation. Further data were obtained from ethnographic observations of blood collection and donor recruitment activities. Thematic analysis resulted in three umbrella themes: leveraging social networks, embedding the clinic in the community, and donating blood and social reciprocity. Donor recruitment activities at all four clinics enhanced awareness of blood donation in the workplace by using experienced donors to motivate their coworkers in making a first-time donation. Clinic employees reported varying success in improving awareness of blood donation in the broader community, in part because of varying employee engagement in community-wide activities and celebrations. Altruistic motives were mentioned by experienced donors, who also identified a desire to reciprocate to their community as another strong motive. This study contextualizes donor recruitment and retention as involving activities that tie blood donation to meaningful aspects of donors' social networks and community. The findings point to the need for further analyses of the institutional dimensions of blood donation to develop effective strategies beyond appeals to altruism. © 2013 American Association of Blood Banks.

  11. Predicting blood transfusion in patients undergoing minimally invasive oesophagectomy.

    Science.gov (United States)

    Schneider, Crispin; Boddy, Alex P; Fukuta, Junaid; Groom, William D; Streets, Christopher G

    2014-12-01

    To evaluate predictors of allogenic blood transfusion requirements in patients undergoing minimal invasive oesophagectomy at a tertiary high volume centre for oesophago-gastric surgery. Retrospective analysis of all patients undergoing minimal access oesophagectomy in our department between January 2010 and December 2011. Patients were divided into two groups depending on whether they required a blood transfusion at any time during their index admission. Factors that have been shown to influence perioperative blood transfusion requirements in major surgery were included in the analysis. Binary logistic regression analysis was performed to determine the impact of patient and perioperative characteristics on transfusion requirements during the index admission. A total of 80 patients underwent minimal access oesophagectomy, of which 61 patients had a laparoscopic assisted oesophagectomy and 19 patients had a minimal invasive oesophagectomy. Perioperative blood transfusion was required in 28 patients at any time during hospital admission. On binary logistic regression analysis, a lower preoperative haemoglobin concentration (p blood transfusion requirements. It has been reported that requirement for blood transfusion can affect long-term outcomes in oesophageal cancer resection. Two factors which could be addressed preoperatively; haemoglobin concentration and type of oesophageal resection, may be valuable in predicting blood transfusions in patients undergoing minimally invasive oesophagectomy. Our analysis revealed that preoperative haemoglobin concentration, occurrence of significant complications and type of minimal access oesophagectomy predicted blood transfusion requirements in the patient population examined. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  12. Analysis of perfluoroalkyl substances in cord blood by turbulent flow chromatography coupled to tandem mass spectrometry

    International Nuclear Information System (INIS)

    Llorca, Marta; Pérez, Francisca; Farré, Marinella; Agramunt, Sílvia; Kogevinas, Manolis; Barceló, Damià

    2012-01-01

    A fast on-line analytical method based on turbulent flow chromatography (TFC) in combination with tandem mass spectrometry has been applied for the first time for the analysis of eighteen perfluoroalkyl substances (PFASs), in cord blood. A simple and rapid sample pre-treatment was optimised consisting on protein precipitation of 100 μL of sample with acetonitrile (1:1) followed by centrifugation during 10 min. The method was adapted to be sensitive enough and robust with minimum sample injection volume requirements (20 μL). The optimised methodology presented method limits of detection (MLOD) between 0.031 and 0.76 μg/L, detection capabilities (CCα) in the range between 0.005 and 0.99 μg/L and decision limits (CCβ) ranging from 0.006 to 1.16 μg/L. The recoveries in blank blood were calculated by spiking experiments with a mixture of 18 PFASs and established between 70 and 126% for most of compounds. Isotopic dilution was carried out for quantification of selected analytes. In-house validation of this new approach was carried out according to the requirements in the 2002/657/EC Decision. Finally the good applicability of this new approach was proved by the analysis of 60 cord blood samples from two different Mediterranean cities, Barcelona (Spain) and Heraklion (Greece). Ions perfluorohexanesulfonate (PFHxS) and perfluorooctanesulfonate (PFOS) were found at highest concentration and the more frequently compounds were PFHxS, PFOS and perfluorooctanoic acid (PFOA). The newly developed method proved to be suitable for large-scale epidemiologic studies, and to the data on PFASs exposure during pregnancy. -- Highlights: ► An on-line method has been developed for the analysis of 18 perfluoroalkyl substances. ► The method is based on turbulent flow chromatography tandem mass spectrometry. ► The method was applied in 60 cord blood samples from 2 Mediterranean cities. ► Acidic compounds were more frequently found and the method was proved to be suitable for

  13. Analysis of perfluoroalkyl substances in cord blood by turbulent flow chromatography coupled to tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Llorca, Marta; Perez, Francisca [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Farre, Marinella, E-mail: mfuqam@cid.csic.es [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Agramunt, Silvia [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); Kogevinas, Manolis [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP), Barcelona (Spain); National School of Public Health, Athens (Greece); Barcelo, Damia [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Catalan Institute for Water Research (ICRA), Girona (Spain); King Saud University, Riyadh (Saudi Arabia)

    2012-09-01

    A fast on-line analytical method based on turbulent flow chromatography (TFC) in combination with tandem mass spectrometry has been applied for the first time for the analysis of eighteen perfluoroalkyl substances (PFASs), in cord blood. A simple and rapid sample pre-treatment was optimised consisting on protein precipitation of 100 {mu}L of sample with acetonitrile (1:1) followed by centrifugation during 10 min. The method was adapted to be sensitive enough and robust with minimum sample injection volume requirements (20 {mu}L). The optimised methodology presented method limits of detection (MLOD) between 0.031 and 0.76 {mu}g/L, detection capabilities (CC{alpha}) in the range between 0.005 and 0.99 {mu}g/L and decision limits (CC{beta}) ranging from 0.006 to 1.16 {mu}g/L. The recoveries in blank blood were calculated by spiking experiments with a mixture of 18 PFASs and established between 70 and 126% for most of compounds. Isotopic dilution was carried out for quantification of selected analytes. In-house validation of this new approach was carried out according to the requirements in the 2002/657/EC Decision. Finally the good applicability of this new approach was proved by the analysis of 60 cord blood samples from two different Mediterranean cities, Barcelona (Spain) and Heraklion (Greece). Ions perfluorohexanesulfonate (PFHxS) and perfluorooctanesulfonate (PFOS) were found at highest concentration and the more frequently compounds were PFHxS, PFOS and perfluorooctanoic acid (PFOA). The newly developed method proved to be suitable for large-scale epidemiologic studies, and to the data on PFASs exposure during pregnancy. -- Highlights: Black-Right-Pointing-Pointer An on-line method has been developed for the analysis of 18 perfluoroalkyl substances. Black-Right-Pointing-Pointer The method is based on turbulent flow chromatography tandem mass spectrometry. Black-Right-Pointing-Pointer The method was applied in 60 cord blood samples from 2 Mediterranean cities

  14. Detection of haemoglobins with abnormal oxygen affinity by single blood gas analysis and 2,3-diphosphoglycerate measurement.

    Science.gov (United States)

    Guerrini, G; Morabito, A; Samaja, M

    2000-10-01

    The aim is to determine if a single measurement of blood 2,3-diphosphoglycerate combined with gas analysis (pH, PCO2, PO2 and saturation) can identify the cause of an altered blood-oxygen affinity: the presence of an abnormal haemoglobin or a red cell disorder. The population (n=94) was divided into healthy controls (A, n=14), carriers of red cell disorders (B, n=72) and carriers of high oxygen affinity haemoglobins (C, n=8). Those variables were measured both in samples equilibrated at selected PCO2 and PO2 and in venous blood. In the univariable approach applied to equilibrated samples, we correctly identified C subjects in 93.6% or 96.8% of the cases depending on the selected variable, the standard P50 (PO2 at which 50% of haemoglobin is oxygenated) or a composite variable calculated from the above measurements. After introducing the haemoglobin concentration as a further discriminating variable, the A and B subjects were correctly identified in 91.9% or 94.2% of the cases, respectively. These figures become 93.0% or 86.1%, and 93.7% or 94.9% of the cases when using direct readings from venous blood, thereby avoiding the blood equilibration step. This test is feasible also in blood samples stored at 4 degrees C for 48 h, or at room temperature for 8 h.

  15. Blood conservation operations in pediatric cardiac patients: a paradigm shift of blood use.

    Science.gov (United States)

    Karimi, Mohsen; Florentino-Pineda, Ivan; Weatherred, Ted; Qadeer, Ahsan; Rosenberg, Carol Ann; Hudacko, Andrea; Ryu, Duchwan

    2013-03-01

    Red blood cell transfusion is associated with high morbidity in pediatric patients undergoing cardiac operations. The aim of this study was to evaluate the clinical effects and outcomes of blood conservation for our pediatric patients undergoing cardiac operations. We retrospectively analyzed a collected database of 168 pediatric patients who underwent biventricular (BV) and univentricular (UV) cardiac operations from 2006 to 2010. Patients were grouped into no blood conservation (n = 86 [BV = 74, UV = 12]) and blood conservation (n = 82 [BV = 68, UV = 14]) cohorts. There were no statistical differences in age, sex, weight, and preoperative or postoperative hemoglobin levels in the BV groups. Even though the blood conservation group had longer cardiopulmonary bypass (CPB) (p conservation group, there were no statistical differences in age, sex, weight, CPB and cross-clamp times, preoperative and postoperative hemoglobin levels, and red blood cell transfusions despite lower intraoperative hemoglobin levels (p conservation group. Logistic regression analysis demonstrated a significant correlation between intraoperative blood transfusion and increased inotropic score, longer duration on the ventilator, and increased length of hospitalization. Blood conservation in pediatric cardiac operations is associated with fewer ventilator days, lower inotropic scores, and shorter lengths of stay. These findings, in addition to attendant risks and side effects of blood transfusion and the rising cost of safer blood products, justify blood conservation in pediatric cardiac operations. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. [Nailfold capillaroscopy and blood flow laser-doppler analysis of the microvascular damage in systemic sclerosis: preliminary results].

    Science.gov (United States)

    Secchi, M E; Sulli, A; Pizzorni, C; Cutolo, M

    2009-01-01

    Systemic sclerosis (SSc) is characterized by altered microvascular structure and function. Nailfold videocapillaroscopy (NVC) is the tool to evaluate capillary morphological structure and laser-Doppler Blood flowmetry (LDF) can be used to estimate cutaneous blood flow of microvessels. The aim of this study was to investigate possible relationships between capillary morphology and blood flow in SSc. Twenty-seven SSc patients and 12 healthy subjects were enrolled. SSc microvascular involvement, as evaluated by NVC, was classified in three different patterns ("Early", "Active", "Late"). LDF analysis was performed at the II, III, IV, V hand fingers in both hands and both at cutaneous temperature and at 36 degrees C. Statistical evaluation was carried out by non-parametric procedures. Blood flow was found significantly lower in SSc patients when compared with healthy subjects (p<0.05). The heating of the probe to 36 degrees C induced a significant increase in peripheral blood flow in all subjects compared to baseline (p <0.05), however, the amount of variation was significantly lower in patients with SSc, compared with healthy controls (p <0.05). The SSc patients with NVC "Late" pattern, showed lower values of peripheral blood flow than patients with NVC "Active" or "Early" patterns (p<0.05). Moreover, a negative correlation between the tissue perfusion score and the progression of the SSc microangiopathy was observed, as well as between the tissue perfusion and the duration of the Raynaud's phenomenon (p <0.03). LDF can be employed to evaluate blood perfusion in the microvascular circulation in SSc patients. The blood flow changes observed with the LDF seem to correlate with the severity of microvascular damage in SSc as detected by NVC.

  17. Analysis of hemoglobin adducts from acrylamide, glycidamide, and ethylene oxide in paired mother/cord blood samples from Denmark

    DEFF Research Database (Denmark)

    von Stedingk, Hans; Vikström, Anna C; Rydberg, Per

    2011-01-01

    The knowledge about fetal exposure to acrylamide/glycidamide from the maternal exposure through food is limited. Acrylamide, glycidamide, and ethylene oxide are electrophiles and form adducts with hemoglobin (Hb), which could be used for in vivo dose measurement. In this study, a method.......20-0.73) for glycidamide, and 0.43 (range 0.17-1.34) for ethylene oxide. In vitro studies with acrylamide and glycidamide showed a lower (0.38-0.48) rate of adduct formation with Hb in cord blood than with Hb in maternal blood, which is compatible with the structural differences in fetal and adult Hb. Together...... for analysis of Hb adducts by liquid chromatography-mass spectrometry, the adduct FIRE procedure, was applied to measurements of adducts from these compounds in maternal blood samples (n = 87) and umbilical cord blood samples (n = 219). The adduct levels from the three compounds, acrylamide, glycidamide...

  18. COMPARATIVE ANALYSIS OF BLOOD GROUPING IN HEALTHY BLOOD DONOR USING GEL CARD TECHNIQUE AND TUBE METHOD

    Directory of Open Access Journals (Sweden)

    Muhammad Usman

    2016-12-01

    Full Text Available Blood grouping is a vital test in pre-transfusion testing. Both tube and gel agglutination assays are used for ABO grouping. The main object of this study was to compare ABO grouping and D typing on tube and gel agglutination assay in order to assess the efficacy of each technique. A total of 100 healthy blood donors irrespective of age and sex were included in this study. Results showed that there is no significant difference between these two techniques. However, in 10 samples it was detected that the reaction strength in serum ABO grouping by gel agglutination assay is varied by only one grade when compared to tube agglutination assay. Due to numerous positive effects of gel assay it is more beneficial to implement this technique in the setups where blood banks bear heavy routine work load.

  19. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    Science.gov (United States)

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1985-08-05

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.

  20. Preventing blood transfusion failures: FMEA, an effective assessment method.

    Science.gov (United States)

    Najafpour, Zhila; Hasoumi, Mojtaba; Behzadi, Faranak; Mohamadi, Efat; Jafary, Mohamadreza; Saeedi, Morteza

    2017-06-30

    Failure Mode and Effect Analysis (FMEA) is a method used to assess the risk of failures and harms to patients during the medical process and to identify the associated clinical issues. The aim of this study was to conduct an assessment of blood transfusion process in a teaching general hospital, using FMEA as the method. A structured FMEA was recruited in our study performed in 2014, and corrective actions were implemented and re-evaluated after 6 months. Sixteen 2-h sessions were held to perform FMEA in the blood transfusion process, including five steps: establishing the context, selecting team members, analysis of the processes, hazard analysis, and developing a risk reduction protocol for blood transfusion. Failure modes with the highest risk priority numbers (RPNs) were identified. The overall RPN scores ranged from 5 to 100 among which, four failure modes were associated with RPNs over 75. The data analysis indicated that failures with the highest RPNs were: labelling (RPN: 100), transfusion of blood or the component (RPN: 100), patient identification (RPN: 80) and sampling (RPN: 75). The results demonstrated that mis-transfusion of blood or blood component is the most important error, which can lead to serious morbidity or mortality. Provision of training to the personnel on blood transfusion, knowledge raising on hazards and appropriate preventative measures, as well as developing standard safety guidelines are essential, and must be implemented during all steps of blood and blood component transfusion.

  1. Local corticosteroid versus autologous blood injections in lateral epicondylitis: meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Sirico, Felice; Ricca, Flavia; DI Meglio, Franca; Nurzynska, Daria; Castaldo, Clotilde; Spera, Rocco; Montagnani, Stefania

    2017-06-01

    Lateral epicondylitis is a common painful elbow disorder. Several approaches to treatment have been proposed, with a local injection of corticosteroids being the most frequently used. Recent insights into the pathophysiology encouraged the introduction of autologous blood injections as an alternative treatment method. The aim of this meta-analysis is to summarize quantitatively the evidence regarding the efficacy of corticosteroids and autologous blood injections for treatment of pain in lateral epicondylitis. Studies were considered eligible based on the following inclusion criteria: adult human, diagnosis of lateral epicondylitis, randomized controlled trials comparing corticosteroids versus autologous blood injections, pain assessment. Exclusion criteria were previous surgery for lateral epicondylitis or for other elbow disorders, concurrent treatment with drugs or physiotherapy, diagnosis of musculoskeletal systemic disorder. A systematic search of literature was performed according to the PRISMA statement. Effect size of each included study was calculated and analyzed in a random-effects model. Four studies, enrolling total of 218 patients (139 females and 79 males), were included in quantitative analysis. At 2 weeks, there was a trend towards a reduction of VAS score in the corticosteroid group (WMD=2.12 [95% CI: 4.38 to 0.14], P=0.07). No significant differences were recorded in the medium-term (4-12 weeks; WMD=0.85 [95% CI: -0.44 to 2.15], P=0.19) and long-term (24 weeks; WMD=0.63 [95% CI: -2.40 to 3.66], P=0.68) follow-up. Few high-quality trials compare the efficacy of corticosteroid and autologous blood injections in the control of pain related to lateral epicondylitis. Available data indicate that corticosteroids tend to reduce VAS score in short-term follow-up, although these data are not statistically significant. No differences were recorded in the medium and long term. Contrary to popular opinion among medical professionals, and despite

  2. Trends of Blood and Plasma Donations in Kazakhstan: 12-Years Retrospective Analysis.

    Science.gov (United States)

    Igissinov, Nurbek; Kulmirzayeva, Dariyana; Magzumova, Raushan; Sibinga, Cees Th Smit; Alpeissova, Sholpan

    2014-05-01

    Each country faces a continuing challenge to collect enough blood to meet the national needs. According to WHO, there should be at least 20 blood donations per 1,000 population for developing countries, in Kazakhstan this indicator was only 16.8 in 2011. Thus, we conducted an epidemiological assessment and drew a map of the regional distribution of blood and plasma donations in Kazakhstan during the years 2000-2011. The retrospective study was conducted from 2000 to 2011. Data on blood and its components donations were acquired from the Ministry of Health (annual statistical reporting form N° 39). During 2000-2011, number of blood donors decreased to 17.4% and blood donations to 6.3%. The proportion of non-remunerated blood donations and donors decreased from 97.6% to 77.9% and 97.9% to 87.7%, respectively. The paid donations had the opposite trend. Number of plasma donors increased in 2.1 times, plasma donations in 2.4 times, nevertheless the proportion of non-remunerated plasma donations decreased from 60.1% to 29.8%. The average number of blood donations per 1,000 population decreased from 19.8 (2000) to 16.8 (2011), plasma donations increased from 1.4 to 3.1. Regionally, annual average rates of blood and plasma donations per 1,000 population over 12 years varied greatly. This is the first study conducted in Kazakhstan to provide detailed information, including the regional characteristics of blood and plasma donations over an extended period of time, which can be used in blood transfusion services work.

  3. Applications of blood group genotyping

    Directory of Open Access Journals (Sweden)

    Mariza A. Mota

    2006-03-01

    Full Text Available Introduction: The determination of blood group polymorphism atthe genomic level facilitates the resolution of clinical problemsthat cannot be addressed by hemagglutination. They are useful to(a determine antigen types for which currently available antibodiesare weakly reactive; (b type patients who have been recentlytransfused; (c identify fetuses at risk for hemolytic disease of thenewborn; and (d to increase the reliability of repositories of antigennegative RBCs for transfusion. Objectives: This review assessedthe current applications of blood group genotyping in transfusionmedicine and hemolytic disease of the newborn. Search strategy:Blood group genotyping studies and reviews were searched ingeneral database (MEDLINE and references were reviewed.Selection criteria: All published data and reviews were eligible forinclusion provided they reported results for molecular basis ofblood group antigens, DNA analysis for blood group polymorphisms,determination of fetal group status and applications of blood groupgenotyping in blood transfusion. Data collection: All data werecollected based on studies and reviews of blood grouppolymorphisms and their clinical applications.

  4. Blood pressure-lowering treatment based on cardiovascular risk: a meta-analysis of individual patient data.

    Science.gov (United States)

    2014-08-16

    We aimed to investigate whether the benefits of blood pressure-lowering drugs are proportional to baseline cardiovascular risk, to establish whether absolute risk could be used to inform treatment decisions for blood pressure-lowering therapy, as is recommended for lipid-lowering therapy. This meta-analysis included individual participant data from trials that randomly assigned patients to either blood pressure-lowering drugs or placebo, or to more intensive or less intensive blood pressure-lowering regimens. The primary outcome was total major cardiovascular events, consisting of stroke, heart attack, heart failure, or cardiovascular death. Participants were separated into four categories of baseline 5-year major cardiovascular risk using a risk prediction equation developed from the placebo groups of the included trials (21%). 11 trials and 26 randomised groups met the inclusion criteria, and included 67,475 individuals, of whom 51,917 had available data for the calculation of the risk equations. 4167 (8%) had a cardiovascular event during a median of 4·0 years (IQR 3·4-4·4) of follow-up. The mean estimated baseline levels of 5-year cardiovascular risk for each of the four risk groups were 6·0% (SD 2·0), 12·1% (1·5), 17·7% (1·7), and 26·8% (5·4). In each consecutive higher risk group, blood pressure-lowering treatment reduced the risk of cardiovascular events relatively by 18% (95% CI 7-27), 15% (4-25), 13% (2-22), and 15% (5-24), respectively (p=0·30 for trend). However, in absolute terms, treating 1000 patients in each group with blood pressure-lowering treatment for 5 years would prevent 14 (95% CI 8-21), 20 (8-31), 24 (8-40), and 38 (16-61) cardiovascular events, respectively (p=0·04 for trend). Lowering blood pressure provides similar relative protection at all levels of baseline cardiovascular risk, but progressively greater absolute risk reductions as baseline risk increases. These results support the use of predicted baseline cardiovascular

  5. Garlic Lowers Blood Pressure in Hypertensive Individuals, Regulates Serum Cholesterol, and Stimulates Immunity: An Updated Meta-analysis and Review.

    Science.gov (United States)

    Ried, Karin

    2016-02-01

    Garlic has been shown to have cardiovascular protective and immunomodulatory properties. We updated a previous meta-analysis on the effect of garlic on blood pressure and reviewed the effect of garlic on cholesterol and immunity. We searched the Medline database for randomized controlled trials (RCTs) published between 1955 and December 2013 on the effect of garlic preparations on blood pressure. In addition, we reviewed the effect of garlic on cholesterol and immunity. Our updated meta-analysis on the effect of garlic on blood pressure, which included 20 trials with 970 participants, showed a mean ± SE decrease in systolic blood pressure (SBP) of 5.1 ± 2.2 mm Hg (P garlic on blood lipids, which included 39 primary RCTs and 2300 adults treated for a minimum of 2 wk, suggested garlic to be effective in reducing total and LDL cholesterol by 10% if taken for >2 mo by individuals with slightly elevated concentrations [e.g., total cholesterol >200 mg/dL (>5.5 mmol/L)]. Garlic has immunomodulating effects by increasing macrophage activity, natural killer cells, and the production of T and B cells. Clinical trials have shown garlic to significantly reduce the number, duration, and severity of upper respiratory infections. Our review suggests that garlic supplements have the potential to lower blood pressure in hypertensive individuals, to regulate slightly elevated cholesterol concentrations, and to stimulate the immune system. Garlic supplements are highly tolerated and may be considered as a complementary treatment option for hypertension, slightly elevated cholesterol, and stimulation of immunity. Future long-term trials are needed to elucidate the effect of garlic on cardiovascular morbidity and mortality. © 2016 American Society for Nutrition.

  6. Systematic review and meta-analysis of circulating S100B blood levels in schizophrenia.

    Directory of Open Access Journals (Sweden)

    Katina Aleksovska

    Full Text Available S100B is a calcium-binding protein secreted in central nervous system from astrocytes and other glia cells. High blood S100B levels have been linked to brain damage and psychiatric disorders. S100B levels have been reported to be higher in schizophrenics than healthy controls. To quantify the relationship between S100B blood levels and schizophrenia a systematic literature review of case-control studies published on this topic within July 3rd 2014 was carried out using three bibliographic databases: Medline, Scopus and Web of Science. Studies reporting mean and standard deviation of S100B blood levels both in cases and controls were included in the meta-analysis. The meta-Mean Ratio (mMR of S100B blood levels in cases compared to controls was used as a measure of effect along with its 95% Confidence Intervals (CI. 20 studies were included totaling for 994 cases and 785 controls. Schizophrenia patients showed 76% higher S100B blood levels than controls with mMR = 1.76 95% CI: 1.44-2.15. No difference could be found between drug-free patients with mMR = 1.84 95%CI: 1.24-2.74 and patients on antipsychotic medication with mMR = 1.75 95% CI: 1.41-2.16. Similarly, ethnicity and stage of disease didn't affect results. Although S100B could be regarded as a possible biomarker of schizophrenia, limitations should be accounted when interpreting results, especially because of the high heterogeneity that remained >70%, even after carrying out subgroups analyses. These results point out that approaches based on traditional categorical diagnoses may be too restrictive and new approaches based on the characterization of new complex phenotypes should be considered.

  7. The effects of hypotension on differences between the results of simultaneous venous and arterial blood gas analysis

    Directory of Open Access Journals (Sweden)

    Farhad Shirani

    2011-01-01

    Full Text Available Background: Analysis of venous blood gas (VBG can represent arterial blood gas (ABG analysis in patients with various diseases. The effects of hypotension on differences between the results of simultaneous venous and arterial blood gas analyses were reviewed. Methods: This observational, cross-sectional study was conducted from March to October 2010 in emergency depart-ments of two university hospitals in Tehran (Iran on consecutive adult patients for whom ABG had been indicated for diagnosis/treatment. Arterial and peripheral venous bloods were simultaneously sampled with blood pressure measure-ment. The VBG-ABG amount of difference regarding pH, HCO 3 , PCO 2 , PO 2 , SO 2 , and Base Excess (BE was com-pared between those with and without hypotension. Results: During the study, 192 patients (51.6 ± 23.6 years, 67.7% males were entered into the hypotension (n = 78 and normotensive groups (n = 114. The average VBG-ABG amount of difference (95% limits of agreement in the hypotension versus normotensive group were -0.030 (-0.09 to 0.03 vs. -0.016 (-0.1 to 0.068 for pH (p = 0.01, 1.79 (-1.91 to 5.49 vs. 1.32 (-1.94 to 4.58 mEq/L for HCO 3 (p = 0.032, 2.69 (-20.43 to 25.81 vs. 2.03 (-7.75 to 11.81 mmHg for PCO 2 (p = 0.295, -35.97 (-130.17 to 58.23 vs. -32.65 (-104.79 to 39.49 mmHg for PO 2 (p = 0.293, -18.58 (-14.66 to 51.82 vs. -9.06 (-31.28 to 13.16 percent (p < 0.001 for SO 2 , and 0.25 (-3.73 to 4.23 vs. 0.79 (-2.51 to 4.09 for BE (p = 0.036. Conclusions: Hypotensive status is associated with an increase in the amount of difference between VBG and ABG analysis regarding pH, HCO 3 , and BE, though the amount of increase does not seem to be clinically important. Studying the precise effects of replacing ABG with VBG on the clinical decision-making and the following outcomes is worth-while.

  8. Incidence and Risk Factors for Blood Transfusion in Total Joint Arthroplasty: Analysis of a Statewide Database.

    Science.gov (United States)

    Slover, James; Lavery, Jessica A; Schwarzkopf, Ran; Iorio, Richard; Bosco, Joseph; Gold, Heather T

    2017-09-01

    Significant attempts have been made to adopt practices to minimize blood transfusion after total joint arthroplasty (TJA) because of transfusion cost and potential negative clinical consequences including allergic reactions, transfusion-related lung injuries, and immunomodulatory effects. We aimed to evaluate risk factors for blood transfusion in a large cohort of TJA patients. We used the all-payer California Healthcare Cost and Utilization Project data from 2006 to 2011 to examine the trends in utilization of blood transfusion among arthroplasty patients (n = 320,746). We performed descriptive analyses and multivariate logistic regression clustered by hospital, controlling for Deyo-Charlson comorbidity index, age, insurance type (Medicaid vs others), gender, procedure year, and race/ethnicity. Eighteen percent (n = 59,038) of TJA patients underwent blood transfusion during their surgery, from 15% with single knee to 45% for bilateral hip arthroplasty. Multivariate analysis indicated that compared with the referent category of single knee arthroplasty, single hip had a significantly higher odds of blood transfusion (odds ratio [OR], 1.76; 95% confidence interval [CI], 1.68-1.83), as did bilateral knee (OR, 3.57; 95% CI, 3.20-3.98) and bilateral hip arthroplasty (OR, 6.17; 95% CI, 4.85-7.85). Increasing age (eg, age ≥80 years; OR, 2.99; 95% CI, 2.82-3.17), Medicaid insurance (OR, 1.36; 95% CI, 1.27-1.45), higher comorbidity index (eg, score of ≥3; OR, 2.33; 95% CI, 2.22-2.45), and females (OR, 1.75; 95% CI, 1.70-1.80) all had significantly higher odds of blood transfusion after TJA. Primary hip arthroplasties have significantly greater risk of transfusion than knee arthroplasties, and bilateral procedures have even greater risk, especially for hips. These factors should be considered when evaluating the risk for blood transfusions. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Analysis of the impact of race on blood transfusion in pediatric scoliosis surgery.

    Science.gov (United States)

    Maher, Keila M; Owusu-Akyaw, Kwadwo; Zhou, Jingzhu; Cooter, Mary; Ross, Allison K; Lark, Robert K; Taicher, Brad M

    2018-04-01

    Surgical correction of pediatric scoliosis is associated with significant blood loss. Minimizing estimated blood loss and blood transfusion is beneficial as transfusions have been associated with increased morbidity, including risk of surgical site infections, longer hospitalizations, and increased cost. Although there is evidence that African-American or Black adults are more likely to require intraoperative blood transfusion compared with Caucasian or White adults, the reasons for this difference are unclear. The electronic records for all patients blood loss/transfusion in primary pediatric scoliosis surgery. In a multivariate model, Black race was independently associated with 1.61 times higher estimated blood loss than White race (P blood transfusion was 6.25 times higher (P = .03; 95% CI = 1.56-25.06) and among the patients who received blood transfusion, Black race was independently associated with 2.61 times greater volume of blood transfusion than White race (P blood loss, increased rate of blood transfusion, and increased amount of blood transfused during surgical correction of pediatric scoliosis. Further investigation is needed to better understand the etiology of the disparity and assess opportunities for improving outcomes. © 2018 John Wiley & Sons Ltd.

  10. Microfluidic-Based Bacteria Isolation from Whole Blood for Diagnostics of Blood Stream Infection.

    Science.gov (United States)

    Zelenin, Sergey; Ramachandraiah, Harisha; Faridi, Asim; Russom, Aman

    2017-01-01

    Bacterial blood stream infection (BSI) potentially leads to life-threatening clinical conditions and medical emergencies such as severe sepsis, septic shock, and multi organ failure syndrome. Blood culturing is currently the gold standard for the identification of microorganisms and, although it has been automated over the decade, the process still requires 24-72 h to complete. This long turnaround time, especially for the identification of antimicrobial resistance, is driving the development of rapid molecular diagnostic methods. Rapid detection of microbial pathogens in blood related to bloodstream infections will allow the clinician to decide on or adjust the antimicrobial therapy potentially reducing the morbidity, mortality, and economic burden associated with BSI. For molecular-based methods, there is a lot to gain from an improved and straightforward method for isolation of bacteria from whole blood for downstream processing.We describe a microfluidic-based sample-preparation approach that rapidly and selectively lyses all blood cells while it extracts intact bacteria for downstream analysis. Whole blood is exposed to a mild detergent, which lyses most blood cells, and then to osmotic shock using deionized water, which eliminates the remaining white blood cells. The recovered bacteria are 100 % viable, which opens up possibilities for performing drug susceptibility tests and for nucleic-acid-based molecular identification.

  11. Relationship of blood lead levels and blood pressure in NHANES II: additional calculations

    International Nuclear Information System (INIS)

    Gartside, P.S.

    1988-01-01

    In performing research for associations and relationships among the data thus far published from the NHANES II survey, only the data for the 64 communities involved may be used. The simple omission of a few essential data makes impossible any valid analysis from the data for the 20,325 individual respondents. In this research for associations between blood lead levels and blood pressure in NHANES II, the method of forward stepwise regression was used. This avoids the problem of inflated error rates for blood lead, maximizes the number of data analyzed, and minimizes the number of independent variables entered into the regression model, thus avoiding the pitfalls that previous NHANES II research of blood lead and blood pressure has fallen into when using backward stepwise regression. The results of this research for white male adults, white female adults, and black adults were contradictory and lacked consistency and reliability. In addition, the overall average association between blood lead level and blood pressure was so minute that the only rational conclusion is that there is no evidence for this association to be found in the NHANES II data

  12. Prediction of blood pressure and blood flow in stenosed renal arteries using CFD

    Science.gov (United States)

    Jhunjhunwala, Pooja; Padole, P. M.; Thombre, S. B.; Sane, Atul

    2018-04-01

    In the present work an attempt is made to develop a diagnostive tool for renal artery stenosis (RAS) which is inexpensive and in-vitro. To analyse the effects of increase in the degree of severity of stenosis on hypertension and blood flow, haemodynamic parameters are studied by performing numerical simulations. A total of 16 stenosed models with varying degree of stenosis severity from 0-97.11% are assessed numerically. Blood is modelled as a shear-thinning, non-Newtonian fluid using the Carreau model. Computational Fluid Dynamics (CFD) analysis is carried out to compute the values of flow parameters like maximum velocity and maximum pressure attained by blood due to stenosis under pulsatile flow. These values are further used to compute the increase in blood pressure and decrease in available blood flow to kidney. The computed available blood flow and secondary hypertension for varying extent of stenosis are mapped by curve fitting technique using MATLAB and a mathematical model is developed. Based on these mathematical models, a quantification tool is developed for tentative prediction of probable availability of blood flow to the kidney and severity of stenosis if secondary hypertension is known.

  13. A Meta-Analysis of Blood Glucose Effects on Human Decision Making

    DEFF Research Database (Denmark)

    Orquin, Jacob L.; Kurzban, Robert

    2016-01-01

    identified 42 studies relating to 4 dimensions of decision making: willingness to pay, willingness to work, time discounting, and decision style. We did not find a uniform influence of blood glucose on decision making. Instead, we found that low levels of blood glucose increase the willingness to pay...... and willingness to work when a situation is food related, but decrease willingness to pay and work in all other situations. Low levels of blood glucose increase the future discount rate for food; that is, decision makers become more impatient, and to a lesser extent increase the future discount rate for money....... Low levels of blood glucose also increase the tendency to make more intuitive rather than deliberate decisions. However, this effect was only observed in situations unrelated to food. We conclude that blood glucose has domain-specific effects, influencing decision making differently depending...

  14. Effect of perioperative blood transfusion on the long-term survival of patients undergoing esophagectomy for esophageal cancer: a systematic review and meta-analysis.

    Science.gov (United States)

    Boshier, P R; Ziff, C; Adam, M E; Fehervari, M; Markar, S R; Hanna, G B

    2017-12-18

    Perioperative blood transfusion has been linked to poorer long-term survival in patients undergoing esophagectomy, presumably due to its potential immunomodulatory effects. This review aims to summarize existing evidence relating to the influence of blood transfusion on long-term survival following esophagectomy for esophageal cancer. A systematic literature search (up to February 2017) was conducted for studies reporting the effects of perioperative blood transfusion on survival following esophagectomy for esophageal cancer. Meta-analysis was used to summate survival outcomes. Twenty observational studies met the criteria for inclusion. Eighteen of these studies compared the outcomes of patients who received allogenic blood transfusion to patients who did not receive this intervention. Meta-analysis of outcomes revealed that allogenic blood transfusion significantly reduced long-term survival (HR = 1.49; 95% CI 1.26 to 1.76; P blood having lower long-term survival compared to patient who received between 0 and 2 units (HR = 1.59; 95% CI 1.31 to 1.93; P blood transfusion showed superior survival in the latter group. Factors associated with the requirement for perioperative blood transfusion included: intraoperative blood loss; preoperative hemoglobin; operative approach; operative time, and; presences of advanced disease. These findings indicate that perioperative blood transfusion is associated with significantly worse long-term survival in patients undergoing esophagectomy for esophageal cancer. Autologous donation of blood, meticulous intraoperative hemostasis, and avoidance of unnecessary transfusions may prevent additional deaths attributed to this intervention. © The Author(s) 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. A rational framework for production decision making in blood establishments.

    Science.gov (United States)

    Ramoa, Augusto; Maia, Salomé; Lourenço, Anália

    2012-07-24

    SAD_BaSe is a blood bank data analysis software, created to assist in the management of blood donations and the blood production chain in blood establishments. In particular, the system keeps track of several collection and production indicators, enables the definition of collection and production strategies, and the measurement of quality indicators required by the Quality Management System regulating the general operation of blood establishments. This paper describes the general scenario of blood establishments and its main requirements in terms of data management and analysis. It presents the architecture of SAD_BaSe and identifies its main contributions. Specifically, it brings forward the generation of customized reports driven by decision making needs and the use of data mining techniques in the analysis of donor suspensions and donation discards.

  16. EFFECT OF ADDING THE INTERNAL STANDARD TO BLOOD SAMPLES, PRIOR TO THE PREPARATION OF BLOOD SPOTS FOR ACYLCARNITINE ANALYSIS

    OpenAIRE

    Osorio, José Henry; Pourfarzam, Morteza

    2010-01-01

    Background: some general factors can influence when determining acylcarnitines through tandem mass spectrometry. Objective: to study the effect of adding the internal standard to blood samples before the preparation of filter paper cards compared with the addition of internal standard after having the filter paper cards prepared for determining acylcarnitines in blood for tandem mass spectrometry. Methodology: two groups of blood samples were prepared: group one without adding internal standa...

  17. [Hemolysis Performance Analysis of the Centrifugal Maglev Blood Pump].

    Science.gov (United States)

    Wang, Yiwen; Zhang, Fan; Fang, Yuan; Dong, Baichuan; Zhou, Liang

    2016-05-01

    In order to analyze and study the hemolysis performance of the centrifugal maglev blood pump, which was designed by ourselves, this paper built the mathematical model and computational fluid dynamics analyzed it using Fluent. Then we set up the in vitro hemolysis experiment platform, in case of the design condition, the content of free hemoglobin and hematocrit in plasma were measured in a certain time interval, and calculated the normalized index of hemolysis of the blood pump. The numerical simulation results show the internal static pressure distribution is smooth inside the pump, the wal shear stress inside the pump is less than 150 Pa. Therefore, the red blood cel damage and exposure time is independent. The normalized index of hemolysis is (0.002 9±0.000 7) mg/L, which is in accordance with human physiological requirement.

  18. Quantitative evaluation of regional blood flow in pulmonary sarcoidosis with Bull's eye analysis

    International Nuclear Information System (INIS)

    Akaki, Shiro

    1991-01-01

    Lung perfusion scintigraphy was performed in 23 patients with pulmonary sarcoidosis and in 11 normal volunteers. Bull's eye analysis was used to analyze regional pulmonary blood flow quantitatively. First, whole lung perfusion images were divided into three regions by three concentric circles. Then radial axes were projected from the center to define 36 x 10deg sectors. The counts for each sector were calculated and a Bull's eye image was displayed. The counts were compared with the lower limit of normal (mean -2SD), and as the indices of reduction in perfusion, extent score (ES) and severity score (SS) were calculated. ES and SS showed significant reduction in perfusion 16 patients (70%) with sarcoidosis. In stage II sarcoidosis, both ES and SS were significantly higher than in stage I sarcoidosis (p 67 Ga scintigraphy findings. In comparison with clinical data, ES had a positive correlation with serum angiotensin-converting enzyme activity (p + /CD8 + ratio (p<0.05). The Bull's eye analysis was considered useful for the quantitative evaluation of regional pulmonary blood flow in pulmonary sarcoidosis, and it was suggested that the mechanism of reduction in perfusion might result mainly in its alveolitis and angitis. Ventilation abnormality, which may happen prior to reduction in perfusion, may be an important factor of reduction in perfusion. (author)

  19. On-chip sample preparation for complete blood count from raw blood.

    Science.gov (United States)

    Nguyen, John; Wei, Yuan; Zheng, Yi; Wang, Chen; Sun, Yu

    2015-03-21

    This paper describes a monolithic microfluidic device capable of on-chip sample preparation for both RBC and WBC measurements from whole blood. For the first time, on-chip sample processing (e.g. dilution, lysis, and filtration) and downstream single cell measurement were fully integrated to enable sample preparation and single cell analysis from whole blood on a single device. The device consists of two parallel sub-systems that perform sample processing and electrical measurements for measuring RBC and WBC parameters. The system provides a modular environment capable of handling solutions of various viscosities by adjusting the length of channels and precisely controlling mixing ratios, and features a new 'offset' filter configuration for increased duration of device operation. RBC concentration, mean corpuscular volume (MCV), cell distribution width, WBC concentration and differential are determined by electrical impedance measurement. Experimental characterization of over 100,000 cells from 10 patient blood samples validated the system's capability for performing on-chip raw blood processing and measurement.

  20. Phase analysis of gated blood pool scintigraphy in traumatic myocardial contusion

    International Nuclear Information System (INIS)

    Nishimaki, Hiroshi; Kobayashi, Akiyoshi

    1994-01-01

    It is not easy to make a diagnosis of myocardial contusion following blunt chest trauma, because most patients have many other concurrent injuries with diverse symptoms. The usefulness of phase analysis of gated blood pool scintigraphy (GBPS) for myocardial contusion following blunt chest trauma was evaluated. Thirty-eight patients who had been strongly suspected of having myocardial contusion from clinical symptoms and electrocardiograms underwent phase analysis of GBPS. The results of phase analysis were compared with those of two-dimensional echocardiography (2-D Echo) and CPK-MB fraction measurement in all patients, with those of 201 TlCl myocardial scintigraphy in 35 patients and with those of 99m Tc-pyrophosphate scintigraphy in 10 patients. In 29 patients (76.3%), the results of phase analysis matched those of 2-D Echo. Two patients (5.3%) who were judged as positive by 2-D Echo and as negative by phase analysis had only rupture of the chordae. Only one of two other patients who were judged as negative by 2-D Echo and as positive by phase analysis was judged as positive by 201 TlCl myocardial scintigraphy. The results of both 2-D Echo and phase analysis were not well correlated with those of CPK-MB fraction measurement and 99m Tc pyrophosphate scintigraphy. It is concluded that phase analysis of GBPS, as well as 2-D Echo, is useful for diagnosing myocardial contusion, and that phase analysis is most useful for diagnosing myocardial contusion in patients who cannot be examined by 2-D Echo because of the presence of pneumothorax and/or subcutaneous emphysema in the anterior chest wall. (author)

  1. Phase analysis of gated blood pool scintigraphy in traumatic myocardial contusion

    Energy Technology Data Exchange (ETDEWEB)

    Nishimaki, Hiroshi; Kobayashi, Akiyoshi (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine)

    1994-01-01

    It is not easy to make a diagnosis of myocardial contusion following blunt chest trauma, because most patients have many other concurrent injuries with diverse symptoms. The usefulness of phase analysis of gated blood pool scintigraphy (GBPS) for myocardial contusion following blunt chest trauma was evaluated. Thirty-eight patients who had been strongly suspected of having myocardial contusion from clinical symptoms and electrocardiograms underwent phase analysis of GBPS. The results of phase analysis were compared with those of two-dimensional echocardiography (2-D Echo) and CPK-MB fraction measurement in all patients, with those of [sup 201]TlCl myocardial scintigraphy in 35 patients and with those of [sup 99m]Tc-pyrophosphate scintigraphy in 10 patients. In 29 patients (76.3%), the results of phase analysis matched those of 2-D Echo. Two patients (5.3%) who were judged as positive by 2-D Echo and as negative by phase analysis had only rupture of the chordae. Only one of two other patients who were judged as negative by 2-D Echo and as positive by phase analysis was judged as positive by [sup 201]TlCl myocardial scintigraphy. The results of both 2-D Echo and phase analysis were not well correlated with those of CPK-MB fraction measurement and [sup 99m]Tc pyrophosphate scintigraphy. It is concluded that phase analysis of GBPS, as well as 2-D Echo, is useful for diagnosing myocardial contusion, and that phase analysis is most useful for diagnosing myocardial contusion in patients who cannot be examined by 2-D Echo because of the presence of pneumothorax and/or subcutaneous emphysema in the anterior chest wall. (author).

  2. Analysis of multiple single nucleotide polymorphisms (SNP) on DNA traces from plasma and dried blood samples

    NARCIS (Netherlands)

    Catsburg, Arnold; van der Zwet, Wil C.; Morre, Servaas A.; Ouburg, Sander; Vandenbroucke-Grauls, Christina M. J. E.; Savelkoul, Paul H. M.

    2007-01-01

    Reliable analysis of single nucleotide polymorphisms (SNPs) in DNA derived from samples containing low numbers of cells or from suboptimal sources can be difficult. A new procedure to characterize multiple SNPs in traces of DNA from plasma and old dried blood samples was developed. Six SNPs in the

  3. Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples.

    Science.gov (United States)

    Mohammadhoseini, Elham; Safavi, Enayat; Seifi, Sepideh; Seifirad, Soroush; Firoozbakhsh, Shahram; Peiman, Soheil

    2015-03-01

    Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples. 2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling. PaO2 of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO2 of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes. In samples stored in plastic syringes, overestimation of PaO2 levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.

  4. Income inequality and high blood pressure in Colombia: a multilevel analysis.

    Science.gov (United States)

    Lucumi, Diego I; Schulz, Amy J; Roux, Ana V Diez; Grogan-Kaylor, Andrew

    2017-11-21

    The objective of this research was to examine the association between income inequality and high blood pressure in Colombia. Using a nationally representative Colombian sample of adults, and data from departments and municipalities, we fit sex-stratified linear and logistic multilevel models with blood pressure as a continuous and binary variable, respectively. In adjusted models, women living in departments with the highest quintile of income inequality in 1997 had higher systolic blood pressure than their counterparts living in the lowest quintile of income inequality (mean difference 4.42mmHg; 95%CI: 1.46, 7.39). Women living in departments that were at the fourth and fifth quintile of income inequality in 1994 were more likely to have hypertension than those living in departments at the first quintile in the same year (OR: 1.56 and 1.48, respectively). For men, no associations of income inequality with either systolic blood pressure or hypertension were observed. Our findings are consistent with the hypothesis that income inequality is associated with increased risk of high blood pressure for women. Future studies to analyze pathways linking income inequality to high blood pressure in Colombia are needed.

  5. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  6. HPLC-MS/MS method optimisation for matrix metalloproteinase 3 and matrix metalloproteinase 9 determination in human blood serum using target analysis.

    Science.gov (United States)

    Kotnik, Petra; Krajnc, Metka Koren; Pahor, Artur; Finšgar, Matjaž; Knez, Željko

    2018-02-20

    A quantitative analysis of zinc endopeptidases matrix metalloproteinase 9 (MMP9) and matrix metalloproteinase 3 (MMP3) from human blood serum are presented. Both matrix metalloproteinases (MMP) are present in human blood serum and can be used as biomarkers for different diseases. The analysis was performed using LC-MS/MS with a triple quadrupole mass spectrometer, based on two specific peptides of each MMP in comparison with an enzyme-linked immunosorbent assay (ELISA). While the conditions for the LC-MS/MS analysis of MMP9 peptides were previously reported for bronchoalveolar lavage fluid, the analysis of MMP3 peptides was newly quantified for human blood serum herein for the first time. For MMP3, the linear behaviour was determined in the concentration range from 1.0-200.0ng/mL (R 2 =0.997) with an LLOD of 0.5ng/mL. For MMP9, linearity was determined in the concentration range from 6.5-65.0ng/mL (R 2 =0.995) with an LLOD of 2.0ng/mL. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Nailfold capillaroscopy and blood flow laser-doppler analysis of the microvascular damage in systemic sclerosis: preliminary results

    Directory of Open Access Journals (Sweden)

    C. Pizzorni

    2011-06-01

    Full Text Available Objectives: Systemic sclerosis (SSc is characterized by altered microvascular structure and function. Nailfold videocapillaroscopy (NVC is the tool to evaluate capillary morphological structure and laser-Doppler Blood flowmetry (LDF can be used to estimate cutaneous blood flow of microvessels. The aim of this study was to investigate possible relationships between capillary morphology and blood flow in SSc. Methods: 27 SSc patients and 12 healthy subjects were enrolled. SSc microvascular involvement, as evaluated by NVC, was classified in three different patterns (“Early”, “Active”, “Late”. LDF analysis was performed at the II, III, IV, V hand fingers in both hands and both at cutaneous temperature and at 36°C. Statistical evaluation was carried out by non-parametric procedures. Results: Blood flow was found significantly lower in SSc patients when compared with healthy subjects (p<0.05. The heating of the probe to 36°C induced a significant increase in peripheral blood flow in all subjects compared to baseline (p <0.05, however, the amount of variation was significantly lower in patients with SSc, compared with healthy controls (p <0.05. The SSc patients with NVC “Late” pattern, showed lower values of peripheral blood flow than patients with NVC “Active” or “Early” patterns (p<0.05. Moreover, a negative correlation between the tissue perfusion score and the progression of the SSc microangiopathy was observed, as well as between the tissue perfusion and the duration of the Raynaud’s phenomenon (p <0.03. Conclusions: LDF can be employed to evaluate blood perfusion in the microvascular circulation in SSc patients. The blood flow changes observed with the LDF seem to correlate with the severity of microvascular damage in SSc as detected by NVC.

  8. Prospective evaluation of the diagnostic value of sensitive KIT D816V mutation analysis of blood in adults with suspected systemic mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, H; Bindslev-Jensen, C

    2017-01-01

    BACKGROUND: Sensitive KIT D816V mutation analysis of blood has been proposed to guide bone marrow (BM) investigation in suspected systemic mastocytosis (SM). The aim of this prospective study was for the first time to compare the D816V status of the "screening blood sample" used to guide BM biopsy...... in suspected SM to the outcome of the subsequent BM investigation. METHODS: Fifty-eight adult patients with suspected SM were included. The outcome of sensitive KIT D816V analysis of blood was compared to the result of the BM investigation. RESULTS: Screening blood samples from 44 of 58 patients tested D816V...... patients did not fulfill any diagnostic SM criteria (excluding tryptase criterion). Of the 48 SM patients, 90% tested D816V-positive. Thirteen SM patients presented with Hymenoptera venom-induced anaphylaxis, no skin lesions, and baseline serum tryptase ≤20 ng/mL. Of these, 92% tested D816V...

  9. Statistical analysis of dose heterogeneity in circulating blood: Implications for sequential methods of total body irradiation

    International Nuclear Information System (INIS)

    Molloy, Janelle A.

    2010-01-01

    Purpose: Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these ''sequential'' techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Methods: Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. Results: The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than ±10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times

  10. Statistical analysis of dose heterogeneity in circulating blood: implications for sequential methods of total body irradiation.

    Science.gov (United States)

    Molloy, Janelle A

    2010-11-01

    Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these "sequential" techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than +/- 10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times. However, the EUD was

  11. Comparison of two methods for blood lead analysis in cattle: graphite-furnace atomic absorption spectrometry and LeadCare(R) II system.

    Science.gov (United States)

    Bischoff, Karyn; Gaskill, Cynthia; Erb, Hollis N; Ebel, Joseph G; Hillebrandt, Joseph

    2010-09-01

    The current study compared the LeadCare(R) II test kit system with graphite-furnace atomic absorption spectrometry for blood lead (Pb) analysis in 56 cattle accidentally exposed to Pb in the field. Blood Pb concentrations were determined by LeadCare II within 4 hr of collection and after 72 hr of refrigeration. Blood Pb concentrations were determined by atomic absorption spectrometry, and samples that were coagulated (n = 12) were homogenized before analysis. There was strong rank correlation (R(2) = 0.96) between atomic absorption and LeadCare II (within 4 hr of collection), and a conversion formula was determined for values within the observed range (3-91 mcg/dl, although few had values >40 mcg/dl). Median and mean blood pb concentrations for atomic absorption were 7.7 and 15.9 mcg/dl, respectively; for LeadCare II, medians were 5.2 mcg/dl at 4 hr and 4.9 mcg/dl at 72 hr, and means were 12.4 and 11.7, respectively. LeadCare II results at 4 hr strongly correlated with 72 hr results (R(2) = 0.96), but results at 72 hr were lower (P atomic absorption. Although there have been several articles that compared LeadCare with other analytical techniques, all were for the original system, not LeadCare II. The present study indicated that LeadCare II results correlated well with atomic absorption over a wide range of blood Pb concentrations and that refrigerating samples for up to 72 hr before LeadCare II analysis was acceptable for clinical purposes.

  12. Development of quantification methods for the myocardial blood flow using ensemble independent component analysis for dynamic H215O PET

    International Nuclear Information System (INIS)

    Lee, Byeong Il; Lee, Jae Sung; Lee, Dong Soo; Kang, Won Jun; Lee, Jong Jin; Kim, Soo Jin; Chung, June Key; Lee, Myung Chul; Choi, Seung Jin

    2004-01-01

    Factor analysis and independent component analysis (lCA) has been used for handling dynamic image sequences. Theoretical advantages of a newly suggested ICA method, ensemble ICA, leaded us to consider applying this method to the analysis of dynamic myocardial H 2 15 O PET data. In this study, we quantified patients, blood flow using the ensemble ICA method. Twenty subjects underwent H 2 15 O PET scans using ECAT EXACT 47 scanner and myocardial perfusion SPECT using Vertex scanner. After transmission scanning, dynamic emission scans were initiated simultaneously with the injection of 555∼740 MBq H 2 15 O. Hidden independent components can be extracted from the observed mixed data (PET image) by means of ICA algorithms. Ensemble learning is a variational Bayesian method that provides an analytical approximation to the parameter posterior using a tractable distribution. Variational approximation forms a lower bound on the ensemble likelihood and the maximization of the lower bound is achieved through minimizing the Kullback-Leibler divergence between the true posterior and the variational posterior. In this study, posterior pdf was approximated by a rectified Gaussian distribution to incorporate non-negativity constraint, which is suitable to dynamic images in nuclear medicine. Blood flow was measured in 9 regions - apex, four areas in mid wall, and four areas in base wall. Myocardial perfusion SPECT score and angiography results were compared with the regional blood flow. Major cardiac components were separated successfully by the ensemble ICA method and blood flow could be estimated in 15 among 20 patients. Mean myocardial blood flow was 1.2±0.40 ml/min/g in rest, 1.85±1.12 ml/min/g in stress state. Blood flow values obtained by an operator in two different occasion were highly correlated (r=0.99). In myocardium component image, the image contrast between left ventricle and myocardium was 1:2.7 in average. Perfusion reserve was significantly different between

  13. Quantitative blood flow analysis with digital techniques

    International Nuclear Information System (INIS)

    Forbes, G.

    1984-01-01

    The general principles of digital techniques in quantitating absolute blood flow during arteriography are described. Results are presented for a phantom constructed to correlate digitally calculated absolute flow with direct flow measurements. The clinical use of digital techniques in cerebrovascular angiography is briefly described. (U.K.)

  14. Comparative analysis of blood and saliva expression profiles in chronic and refractory periodontitis patients.

    Science.gov (United States)

    Zhang, Bin; Lin, Ting; He, Hong

    2015-12-24

    This study aimed to identify characteristic representative genes through a comparative analysis of gene expression profiles in the blood and saliva of chronic periodontitis (CP) and refractory periodontitis (RP) patients to provide new treatment strategies that may be helpful in the treatment of different forms of periodontitis. GSE43525 was downloaded from Gene Expression Omnibus. In the dataset, thirteen samples were from blood including 4 controls, 4 CP and 5 RP samples, and ten samples were from saliva including 3 controls, 4 CP and 3 RP samples. After comparing the CP and RP samples, differentially expressed genes (DEGs) between these two types of periodontitis in the blood and saliva samples were identified by an LIMMA package. Then, functional and pathway enrichment analyses were performed by DAVID and KOBAS, respectively. The significantly associated miRNAs in CP and RP were searched by WebGestalt. In total, 213 DEGs in CP and 45 DEGs in RP were identified. Functional enrichment showed that the DEGs of CP were mainly enriched in ribosome and regulation of apoptosis-related pathways in blood as well as saliva, while the DEGs of RP were significantly enriched in immune responses and response to organic substance-related pathways. Several miRNAs, such as miR-381 and miR-494, were identified as being closely associated with CP. In addition, CD24, EST1, MTSS1, ING3, CCND2 and SYNE2 might be potential targets for diagnosis and treatment of CP. The identified DEGs and miRNAs might be potential targets for the treatment of chronic and refractory periodontitis.

  15. Newborn screening blood spot analysis in the UK: influence of spot size, punch location and haematocrit.

    Science.gov (United States)

    Lawson, A J; Bernstone, L; Hall, S K

    2016-03-01

    In dried blood spot analysis, punch location and variations in applied sample volume and haematocrit can produce different measured concentrations of analytes. We investigated the magnitude of these effects in newborn screening in the UK. Heparinized blood spiked with thyroid stimulating hormone (TSH), phenylalanine, tyrosine, leucine, methionine, octanoyl carnitine (C8), and immunoreactive trypsinogen (IRT) was spotted onto filter paper: (i) at a constant haematocrit of 50% at various volumes, and (ii) at a range of haematocrits using a constant volume. Subpunches (3.2 mm) of the dried blood spots were then analysed. Compared with a central punch from a 50 µL blood spot with 50% haematocrit, 10 µL spots can have significantly lower measured concentrations of all analytes, with decreases of 15% or more observed for leucine, methionine, phenylalanine, and tyrosine. Punching at the edge of a spot can increase measured concentrations up to 35%. Higher haematocrit decreased measured TSH and C8 yet increased amino acids and IRT by 15% compared with 50% haematocrit. Lower haematocrits had the opposite effect, but only with higher concentrations of some analytes. Differences in blood spot size, haematocrit and punch location substantially affect measured concentrations for analytes used in the UK newborn screening programme, and this could affect false positive and negative rates. To minimize analytical bias, these variables should be controlled or adjusted for where possible. © The Author(s) 2015.

  16. Weighted gene co-expression network analysis of the peripheral blood from Amyotrophic Lateral Sclerosis patients

    Directory of Open Access Journals (Sweden)

    DeYoung Joseph

    2009-08-01

    Full Text Available Abstract Background Amyotrophic Lateral Sclerosis (ALS is a lethal disorder characterized by progressive degeneration of motor neurons in the brain and spinal cord. Diagnosis is mainly based on clinical symptoms, and there is currently no therapy to stop the disease or slow its progression. Since access to spinal cord tissue is not possible at disease onset, we investigated changes in gene expression profiles in whole blood of ALS patients. Results Our transcriptional study showed dramatic changes in blood of ALS patients; 2,300 probes (9.4% showed significant differential expression in a discovery dataset consisting of 30 ALS patients and 30 healthy controls. Weighted gene co-expression network analysis (WGCNA was used to find disease-related networks (modules and disease related hub genes. Two large co-expression modules were found to be associated with ALS. Our findings were replicated in a second (30 patients and 30 controls and third dataset (63 patients and 63 controls, thereby demonstrating a highly significant and consistent association of two large co-expression modules with ALS disease status. Ingenuity Pathway Analysis of the ALS related module genes implicates enrichment of functional categories related to genetic disorders, neurodegeneration of the nervous system and inflammatory disease. The ALS related modules contain a number of candidate genes possibly involved in pathogenesis of ALS. Conclusion This first large-scale blood gene expression study in ALS observed distinct patterns between cases and controls which may provide opportunities for biomarker development as well as new insights into the molecular mechanisms of the disease.

  17. Association Analysis of FOXO3 Longevity Variants With Blood Pressure and Essential Hypertension.

    Science.gov (United States)

    Morris, Brian J; Chen, Randi; Donlon, Timothy A; Evans, Daniel S; Tranah, Gregory J; Parimi, Neeta; Ehret, Georg B; Newton-Cheh, Christopher; Seto, Todd; Willcox, D Craig; Masaki, Kamal H; Kamide, Kei; Ryuno, Hirochika; Oguro, Ryosuke; Nakama, Chikako; Kabayama, Mai; Yamamoto, Koichi; Sugimoto, Ken; Ikebe, Kazunori; Masui, Yukie; Arai, Yasumichi; Ishizaki, Tatsuro; Gondo, Yasuyuki; Rakugi, Hiromi; Willcox, Bradley J

    2016-11-01

    The minor alleles of 3 FOXO3 single nucleotide polymorphisms (SNPs)- rs2802292 , rs2253310 , and rs2802288 -are associated with human longevity. The aim of the present study was to test these SNPs for association with blood pressure (BP) and essential hypertension (EHT). In a primary study involving Americans of Japanese ancestry drawn from the Family Blood Pressure Program II we genotyped 411 female and 432 male subjects aged 40-79 years and tested for statistical association by contingency table analysis and generalized linear models that included logistic regression adjusting for sibling correlation in the data set. Replication of rs2802292 with EHT was attempted in Japanese SONIC study subjects and of each SNP in a meta-analysis of genome-wide association studies of BP in individuals of European ancestry. In Americans of Japanese ancestry, women homozygous for the longevity-associated (minor) allele of each FOXO3 SNP had 6mm Hg lower systolic BP and 3mm Hg lower diastolic BP compared with major allele homozygotes (Bonferroni corrected P 0.05, respectively). Frequencies of minor allele homozygotes were 3.3-3.9% in women with EHT compared with 9.5-9.6% in normotensive women ( P = 0.03-0.04; haplotype analysis P = 0.0002). No association with BP or EHT was evident in males. An association with EHT was seen for the minor allele of rs2802292 in the Japanese SONIC cohort ( P = 0.03), while in European subjects the minor allele of each SNP was associated with higher systolic and diastolic BP. Longevity-associated FOXO3 variants may be associated with lower BP and EHT in Japanese women.

  18. Blood Pressure Response to Meditation and Yoga: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Park, Seong-Hi; Han, Kuem Sun

    2017-09-01

    To introduce research that presents scientific evidence regarding the effects of mantra and mindfulness meditation techniques and yoga on decreasing blood pressure (BP) in patients who have hypertension. A literature search was performed to identify all studies published between 1946 and 2014 from periodicals indexed in Ovid Medline, EMBASE, CINAHL, PsycINFO, KoreaMed, and NDSL by using the following keywords: "hypertension," "blood pressure," "psychotherapy," "relaxation therapy," "meditation," "yoga," and "mind-body therapy." The Cochrane's Risk of Bias was applied to assess the internal validity of the randomized controlled trial studies. Thirteen studies were analyzed in this meta-analysis by using Review Manager 5.3. Among 510 possible studies, 13 met the selection criteria. Seven examined meditation, and six examined yoga. The meta-analysis indicated that meditation and yoga appeared to decrease both systolic and diastolic BP, which were within similar baseline ranges, and the reduction was statistically significant; however, some results showed little difference. After an in-depth analysis of those results, BP range and patient age were revealed as the factors that affected the different results in some reports. In particular, meditation played a noticeable role in decreasing the BP of subjects older than 60 years of age, whereas yoga seemed to contribute to the decrease of subjects aged less than 60 years. While acknowledging the limitations of this research due to the differences in BP and the participants' ages, meditation and yoga are demonstrated to be effective alternatives to pharmacotherapy. Given that BP decreased with the use of meditation and yoga, and this effect varied in different age groups, scientifically measured outcomes indicate that these practices are safe alternatives in some cases.

  19. Blood pressure-lowering treatment strategies based on cardiovascular risk versus blood pressure: A meta-analysis of individual participant data.

    Science.gov (United States)

    Karmali, Kunal N; Lloyd-Jones, Donald M; van der Leeuw, Joep; Goff, David C; Yusuf, Salim; Zanchetti, Alberto; Glasziou, Paul; Jackson, Rodney; Woodward, Mark; Rodgers, Anthony; Neal, Bruce C; Berge, Eivind; Teo, Koon; Davis, Barry R; Chalmers, John; Pepine, Carl; Rahimi, Kazem; Sundström, Johan

    2018-03-01

    Clinical practice guidelines have traditionally recommended blood pressure treatment based primarily on blood pressure thresholds. In contrast, using predicted cardiovascular risk has been advocated as a more effective strategy to guide treatment decisions for cardiovascular disease (CVD) prevention. We aimed to compare outcomes from a blood pressure-lowering treatment strategy based on predicted cardiovascular risk with one based on systolic blood pressure (SBP) level. We used individual participant data from the Blood Pressure Lowering Treatment Trialists' Collaboration (BPLTTC) from 1995 to 2013. Trials randomly assigned participants to either blood pressure-lowering drugs versus placebo or more intensive versus less intensive blood pressure-lowering regimens. We estimated 5-y risk of CVD events using a multivariable Weibull model previously developed in this dataset. We compared the two strategies at specific SBP thresholds and across the spectrum of risk and blood pressure levels studied in BPLTTC trials. The primary outcome was number of CVD events avoided per persons treated. We included data from 11 trials (47,872 participants). During a median of 4.0 y of follow-up, 3,566 participants (7.5%) experienced a major cardiovascular event. Areas under the curve comparing the two treatment strategies throughout the range of possible thresholds for CVD risk and SBP demonstrated that, on average, a greater number of CVD events would be avoided for a given number of persons treated with the CVD risk strategy compared with the SBP strategy (area under the curve 0.71 [95% confidence interval (CI) 0.70-0.72] for the CVD risk strategy versus 0.54 [95% CI 0.53-0.55] for the SBP strategy). Compared with treating everyone with SBP ≥ 150 mmHg, a CVD risk strategy would require treatment of 29% (95% CI 26%-31%) fewer persons to prevent the same number of events or would prevent 16% (95% CI 14%-18%) more events for the same number of persons treated. Compared with treating

  20. Blood pressure-lowering treatment strategies based on cardiovascular risk versus blood pressure: A meta-analysis of individual participant data.

    Directory of Open Access Journals (Sweden)

    Kunal N Karmali

    2018-03-01

    Full Text Available Clinical practice guidelines have traditionally recommended blood pressure treatment based primarily on blood pressure thresholds. In contrast, using predicted cardiovascular risk has been advocated as a more effective strategy to guide treatment decisions for cardiovascular disease (CVD prevention. We aimed to compare outcomes from a blood pressure-lowering treatment strategy based on predicted cardiovascular risk with one based on systolic blood pressure (SBP level.We used individual participant data from the Blood Pressure Lowering Treatment Trialists' Collaboration (BPLTTC from 1995 to 2013. Trials randomly assigned participants to either blood pressure-lowering drugs versus placebo or more intensive versus less intensive blood pressure-lowering regimens. We estimated 5-y risk of CVD events using a multivariable Weibull model previously developed in this dataset. We compared the two strategies at specific SBP thresholds and across the spectrum of risk and blood pressure levels studied in BPLTTC trials. The primary outcome was number of CVD events avoided per persons treated. We included data from 11 trials (47,872 participants. During a median of 4.0 y of follow-up, 3,566 participants (7.5% experienced a major cardiovascular event. Areas under the curve comparing the two treatment strategies throughout the range of possible thresholds for CVD risk and SBP demonstrated that, on average, a greater number of CVD events would be avoided for a given number of persons treated with the CVD risk strategy compared with the SBP strategy (area under the curve 0.71 [95% confidence interval (CI 0.70-0.72] for the CVD risk strategy versus 0.54 [95% CI 0.53-0.55] for the SBP strategy. Compared with treating everyone with SBP ≥ 150 mmHg, a CVD risk strategy would require treatment of 29% (95% CI 26%-31% fewer persons to prevent the same number of events or would prevent 16% (95% CI 14%-18% more events for the same number of persons treated. Compared with

  1. Comparative Analysis of Compatibility Effects on Invigorating Blood Circulation for Cyperi Rhizoma Series of Herb Pairs Using Untargeted Metabolomics

    Directory of Open Access Journals (Sweden)

    Pei Liu

    2017-09-01

    Full Text Available The mutual-assistance compatibility of Cyperi Rhizoma (Xiangfu, XF and Angelicae Sinensis Radix (Danggui, DG, Chuanxiong Rhizoma (Chuanxiong, CX, Paeoniae Radix Alba (Baishao, BS, or Corydalis Rhizoma (Yanhusuo, YH, found in a traditional Chinese medicine (TCM named Xiang-Fu-Si-Wu Decoction (XFSWD, can produce synergistic and promoting blood effects. Nowadays, XFSWD has been proved to be effective in activating blood circulation and dissipating blood stasis. However, the role of the herb pairs synergistic effects in the formula were poorly understood. In order to quantitatively assess the compatibility effects of herb pairs, mass spectrometry-based untargeted metabolomics studies were performed. The plasma and urine metabolic profiles of acute blood stasis rats induced by adrenaline hydrochloride and ice water and administered with Cyperi Rhizoma—Angelicae Sinensis Radix (XD, Cyperi Rhizoma—Chuanxiong Rhizoma (XC, Cyperi Rhizoma—Paeoniae Radix Alba (XB, Cyperi Rhizoma—Corydalis Rhizoma (XY were compared. Relative peak area of identified metabolites was calculated and principal component analysis (PCA score plot from the potential markers was used to visualize the overall differences. Then, the metabolites results were used with biochemistry indicators and genes expression values as parameters to quantitatively evaluate the compatibility effects of XF series of herb pairs by PCA and correlation analysis. The collective results indicated that the four XF herb pairs regulated glycerophospholipid metabolism, steroid hormone biosynthesis and arachidonic acid metabolism pathway. XD was more prominent in regulating the blood stasis during the four XF herb pairs. This study demonstrated that metabolomics was a useful tool to efficacy evaluation and compatibility effects of TCM elucidation.

  2. The midgut transcriptome of Lutzomyia longipalpis: comparative analysis of cDNA libraries from sugar-fed, blood-fed, post-digested and Leishmania infantum chagasi-infected sand flies

    Directory of Open Access Journals (Sweden)

    Elnaiem Dia-Eldin

    2008-01-01

    Full Text Available Abstract Background In the life cycle of Leishmania within the alimentary canal of sand flies the parasites have to survive the hostile environment of blood meal digestion, escape the blood bolus and attach to the midgut epithelium before differentiating into the infective metacyclic stages. The molecular interactions between the Leishmania parasites and the gut of the sand fly are poorly understood. In the present work we sequenced five cDNA libraries constructed from midgut tissue from the sand fly Lutzomyia longipalpis and analyzed the transcripts present following sugar feeding, blood feeding and after the blood meal has been processed and excreted, both in the presence and absence of Leishmania infantum chagasi. Results Comparative analysis of the transcripts from sugar-fed and blood-fed cDNA libraries resulted in the identification of transcripts differentially expressed during blood feeding. This included upregulated transcripts such as four distinct microvillar-like proteins (LuloMVP1, 2, 4 and 5, two peritrophin like proteins, a trypsin like protein (Lltryp1, two chymotrypsin like proteins (LuloChym1A and 2 and an unknown protein. Downregulated transcripts by blood feeding were a microvillar-like protein (LuloMVP3, a trypsin like protein (Lltryp2 and an astacin-like metalloprotease (LuloAstacin. Furthermore, a comparative analysis between blood-fed and Leishmania infected midgut cDNA libraries resulted in the identification of the transcripts that were differentially expressed due to the presence of Leishmania in the gut of the sand fly. This included down regulated transcripts such as four microvillar-like proteins (LuloMVP1,2, 4 and 5, a Chymotrypsin (LuloChym1A and a carboxypeptidase (LuloCpepA1, among others. Upregulated midgut transcripts in the presence of Leishmania were a peritrophin like protein (LuloPer1, a trypsin-like protein (Lltryp2 and an unknown protein. Conclusion This transcriptome analysis represents the largest set

  3. A policy of routine umbilical cord blood gas analysis decreased missing samples from high-risk births.

    Science.gov (United States)

    Ahlberg, M; Elvander, C; Johansson, S; Cnattingius, S; Stephansson, O

    2017-01-01

    This study compared obstetric units practicing routine or selective umbilical cord blood gas analysis, with respect to the risk of missing samples in high-risk deliveries and in infants with birth asphyxia. This was a Swedish population-based cohort study that used register data for 155 235 deliveries of live singleton infants between 2008 and 2014. Risk ratios and 95% confidence intervals were calculated to estimate the association between routine and selective umbilical cord blood gas sampling strategies and the risk of missing samples. Selective sampling increased the risk ratios when routine sampling was used as the reference, with a value of 1.0, and these were significant in high-risk deliveries and birth asphyxia. The risk ratios for selective sampling were large-for-gestational age (9.07), preterm delivery at up to 36 weeks of gestation (8.24), small-for-gestational age (7.94), two or more foetal scalp blood samples (5.96), an Apgar score of less than seven at one minute (2.36), emergency Caesarean section (1.67) and instrumental vaginal delivery (1.24). Compared with routine sampling, selective umbilical cord blood gas sampling significantly increased the risks of missing samples in high-risk deliveries and in infants with birth asphyxia. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  4. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhkio

    1985-03-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images.

  5. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhiko.

    1985-01-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images. (author)

  6. Continuous intra-arterial blood-gas monitoring

    Science.gov (United States)

    Divers, George A.; Riccitelli, Samuel D.; Blais, Maurice; Hui, Henry K.

    1993-05-01

    Fiber optic technology and optical fluorescence have made the continuous monitoring of arterial blood gases a reality. Practical products that continuously monitor blood gases by use of an invasive sensor are now available. Anesthesiologists and intensive care physicians are beginning to explore the practical implications of this technology. With the advent of intra- arterial blood gas monitors it is possible to assess arterial blood gas values without the labor intensive steps of drawing blood and transporting a blood sample to the lab followed by the actual analysis. These intra-arterial blood gas monitors use new optical sensor technologies that can be reduced in size to the point that the sensor can be inserted into the arterial blood flow through a 20-gauge arterial cannula. In the best of these technologies the sensors accuracy and precision are similar to those in vitro analyzers. This presentation focuses on background technology and in vivo performance of a device developed, manufactured, and marketed by Puritan-Bennett Corporation.

  7. Effects of blueberry supplementation on blood pressure: a systematic review and meta-analysis of randomized clinical trials.

    Science.gov (United States)

    Zhu, Y; Sun, J; Lu, W; Wang, X; Wang, X; Han, Z; Qiu, C

    2017-03-01

    Blueberries belong to the genus Vaccinium of the family Ericaceae. A series of epidemiological studies have demonstrated that blueberry polyphenols, particularly blueberry anthocyanins provide significant beneficial effects for humans. However, the findings of clinical studies have been equivocal. Therefore, we sought to assess the potential anti-hypertensive effects of blueberry supplementation through a meta-analysis of available randomized controlled trials (RCTs). A comprehensive literature search of PubMed, The Cochrane Library, AMED (Allied and Complementary Medicine Database), Embase, Web of Science, Wanfang Database, and China National Knowledge Infrastructure were performed to identify potential studies published before June 2015. The standardized mean difference and 95% confidence interval (CI) were used as summary statistics. Net changes in systolic blood pressure (SBP) and diastolic blood pressure (DBP) between the blueberry and placebo groups were calculated by subtracting the values at the end of follow-up from those at baseline. Meta-regression was used to identify potential moderators of effect size. Six RCT studies with 204 participants were included in our meta-analysis. There was no significant effect of blueberry supplementation on changes in blood pressure (BP) relative to baseline, and there was a mean difference of -0.28 (95% CI: -1.11 to 0.56, I 2 =87%) and -0.5 (95% CI: -1.24 to 0.24, I 2 =84%) mmHg for SBP and DBP, respectively. In summary, the results from this meta-analysis do not favor any clinical efficacy of blueberry supplementation in improving BP. Further well-designed larger RCTs are required to verify the association between blueberry supplementation and BP.

  8. Transcriptome analysis describing new immunity and defense genes in peripheral blood mononuclear cells of rheumatoid arthritis patients.

    Directory of Open Access Journals (Sweden)

    Vitor Hugo Teixeira

    Full Text Available BACKGROUND: Large-scale gene expression profiling of peripheral blood mononuclear cells from Rheumatoid Arthritis (RA patients could provide a molecular description that reflects the contribution of diverse cellular responses associated with this disease. The aim of our study was to identify peripheral blood gene expression profiles for RA patients, using Illumina technology, to gain insights into RA molecular mechanisms. METHODOLOGY/PRINCIPAL FINDINGS: The Illumina Human-6v2 Expression BeadChips were used for a complete genome-wide transcript profiling of peripheral blood mononuclear cells (PBMCs from 18 RA patients and 15 controls. Differential analysis per gene was performed with one-way analysis of variance (ANOVA and P values were adjusted to control the False Discovery Rate (FDR<5%. Genes differentially expressed at significant level between patients and controls were analyzed using Gene Ontology (GO in the PANTHER database to identify biological processes. A differentially expression of 339 Reference Sequence genes (238 down-regulated and 101 up-regulated between the two groups was observed. We identified a remarkably elevated expression of a spectrum of genes involved in Immunity and Defense in PBMCs of RA patients compared to controls. This result is confirmed by GO analysis, suggesting that these genes could be activated systemically in RA. No significant down-regulated ontology groups were found. Microarray data were validated by real time PCR in a set of nine genes showing a high degree of correlation. CONCLUSIONS/SIGNIFICANCE: Our study highlighted several new genes that could contribute in the identification of innovative clinical biomarkers for diagnostic procedures and therapeutic interventions.

  9. Clinicopathologic analysis of Passeriform venous blood reflects transitions in elevation and habitat

    Directory of Open Access Journals (Sweden)

    Heatley JJ

    2013-06-01

    Full Text Available J Jill Heatley,1 Jennifer Cary,2 Karen E Russell,3 Gary Voelker2 1Department of Small Animal Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, 2Department of Wildlife and Fisheries Sciences and Texas A&M Biodiversity Research and Teaching Collections, Texas A&M University, 3Department of Pathobiology, College of Veterinary Medicine and Biomedical Sciences, College Station, TX, USA Abstract: Jugular blood samples from 110 Passeriformes collected at several Texas locations were analyzed for multiple clinicopathologic parameters between April 2010 and August 2011. Electrolyte, blood gas, and select erythrocyte parameters were analyzed on site with a point of care analyzer, and gender, age, body condition score, location, and species were recorded. Many analytes exhibited a Gaussian distribution across species and are reported as a single range. Taxon affected electrolyte and red blood cell parameters, but not most blood gas or acid base variables. Migratory status affected select electrolytes but few blood gas variables. Red blood cell parameters were affected the most by variables of age, taxonomic group, and gender, but not migratory life history. We found significant changes in glucose and numerous acid base analytes in birds sampled from habitats with evolutionarily recent ecologic degradation. We advocate the use of these analytes, particularly venous blood gas values, as determined by a point of care analyzer, as reasonable biomarkers for determination of Passeriform population health, but also recommend that red blood cell parameters and electrolyte concentrations be controlled for age, species, and gender in future studies. Further, based on our investigation, venous blood gas values and acid base balance in Passeriformes can assess the health of an ecosystem. Keywords: avian, biochemistry, blood gas, electrolyte, hematology, Passerine

  10. Sex-specific and blood meal-induced proteins of Anopheles gambiae midguts: analysis by two-dimensional gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Laurent-Winter C

    2003-02-01

    Full Text Available Abstract Background Anopheles gambiae is the main vector of Plasmodium falciparum in Africa. The mosquito midgut constitutes a barrier that the parasite must cross if it is to develop and be transmitted. Despite the central role of the mosquito midgut in the host/parasite interaction, little is known about its protein composition. Characterisation of An. gambiae midgut proteins may identify the proteins that render An. gambiae receptive to the malaria parasite. Methods We carried out two-dimensional gel electrophoresis of An. gambiae midgut proteins and compared protein profiles for midguts from males, sugar-fed females and females fed on human blood. Results Very few differences were detected between male and female mosquitoes for the approximately 375 silver-stained proteins. Male midguts contained ten proteins not detected in sugar-fed or blood-fed females, which are therefore probably involved in male-specific functions; conversely, female midguts contained twenty-three proteins absent from male midguts. Eight of these proteins were specific to sugar-fed females, and another ten, to blood-fed females. Conclusion Mass spectrometry analysis of the proteins found only in blood-fed female midguts, together with data from the recent sequencing of the An. gambiae genome, should make it possible to determine the role of these proteins in blood digestion or parasite receptivity.

  11. Remifentanil Reduces Blood Loss During Orthognathic Surgery.

    Science.gov (United States)

    Matsuura, Nobuyuki; Okamura, Taiki; Ide, Satoko; Ichinohe, Tatsuya

    2017-01-01

    Remifentanil is reported to reduce oral tissue blood flow. We performed a retrospective investigation using logistic regression analysis of anesthesia records to investigate whether the use of remifentanil infusion in a balanced anesthesia technique was useful as a primary technique to reduce blood loss during orthognathic surgery. Subjects were 80 patients who underwent Le Fort I osteotomy and sagittal split ramus osteotomy of the mandible. The variables included gender, age, weight, type of maintenance anesthetic, type and dose or infusion rate of opioid, mean systolic blood pressure (SBP-mean), coefficient of variation of systolic blood pressure (CVSBP) during surgery, mean heart rate (HR-mean), duration of surgery, total blood loss, volume of infusion used, amount of local anesthetic used, body temperature, and urine output. Gender, type of maintenance anesthetic, type of opioid, SBP-mean, CVSBP, HR-mean, and duration of surgery were used as candidates for independent variables. Logistic regression analysis was performed for the selected independent variables with the total blood loss as the dependent variable. The factors associated with the reduction of blood loss were the use of remifentanil (odds ratio, 3.112; 95% CI, 1.166-8.307; P = .023) and smaller CVSBP (odds ratio, 2.747; 95% CI, 1.07-7.053; P = .036). Use of remifentanil and smaller CVSBP were associated with a reduction of blood loss during orthognathic surgery.

  12. A new approach to age-period-cohort analysis using partial least squares regression: the trend in blood pressure in the Glasgow Alumni cohort.

    Directory of Open Access Journals (Sweden)

    Yu-Kang Tu

    2011-04-01

    Full Text Available Due to a problem of identification, how to estimate the distinct effects of age, time period and cohort has been a controversial issue in the analysis of trends in health outcomes in epidemiology. In this study, we propose a novel approach, partial least squares (PLS analysis, to separate the effects of age, period, and cohort. Our example for illustration is taken from the Glasgow Alumni cohort. A total of 15,322 students (11,755 men and 3,567 women received medical screening at the Glasgow University between 1948 and 1968. The aim is to investigate the secular trends in blood pressure over 1925 and 1950 while taking into account the year of examination and age at examination. We excluded students born before 1925 or aged over 25 years at examination and those with missing values in confounders from the analyses, resulting in 12,546 and 12,516 students for analysis of systolic and diastolic blood pressure, respectively. PLS analysis shows that both systolic and diastolic blood pressure increased with students' age, and students born later had on average lower blood pressure (SBP: -0.17 mmHg/per year [95% confidence intervals: -0.19 to -0.15] for men and -0.25 [-0.28 to -0.22] for women; DBP: -0.14 [-0.15 to -0.13] for men; -0.09 [-0.11 to -0.07] for women. PLS also shows a decreasing trend in blood pressure over the examination period. As identification is not a problem for PLS, it provides a flexible modelling strategy for age-period-cohort analysis. More emphasis is then required to clarify the substantive and conceptual issues surrounding the definitions and interpretations of age, period and cohort effects.

  13. Water-Soluble Dried Blood Spot in Protein Analysis: A Proof-of-Concept Study.

    Science.gov (United States)

    Rosting, Cecilie; Gjelstad, Astrid; Halvorsen, Trine Grønhaug

    2015-08-04

    In the present work human chorionic gonadotropin (hCG) was used as a model protein in a proof-of-concept study combining water-soluble dried blood spot (DBS) material in liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based protein analysis. A water-soluble material consisting of commercially available carboxymethyl cellulose (CMC) was evaluated as sampling material for this purpose. The material dissolved readily at physiological pH. Different sample preparation methods were evaluated, and in the final method, 15 μL of whole blood was deposited and dried on CMC before the whole spot was dissolved prior to cleanup by immunoaffinity extraction, tryptic digest, and preconcentration by solid-phase extraction (SPE). The results indicated complete dissolution of hCG from the spots, acceptable limit of detection (LOD) (0.1 IU/mL), linearity (R(2) = 0.959), accuracy (16%), and precision (≤22%). Long-term stability (45 days) of hCG in dried spots at reduced temperatures (≤8 °C) was also demonstrated. The analyte recovery was comparable to the commercially available nonsolvable cellulose material (FTA DMPK-C card).

  14. Intraneural blood flow analysis during an intraoperative Phalen's test in carpal tunnel syndrome.

    Science.gov (United States)

    Yayama, Takafumi; Kobayashi, Shigeru; Awara, Kousuke; Takeno, Kenichi; Miyazaki, Tsuyoshi; Kubota, Masafumi; Negoro, Kohei; Baba, Hisatoshi

    2010-08-01

    Phalen's test has been one of the most significant of clinical signs when making a clinical diagnosis of idiopathic carpal tunnel syndrome (CTS). However, it is unknown whether intraneural blood flow changes during Phalen's test in patients with CTS. In this study, an intraoperative Phalen's test was conducted in patients with CTS to observe the changes in intraneural blood flow using a laser Doppler flow meter. During Phalen's test, intraneural blood flow showed a sharp decrease, which lasted for 1 min. Intraneural blood flow decreased by 56.7%-100% (average, 78.0%) in the median nerve relative to the blood flow before the test. At 1 min after completing the test, intraneural blood flow returned to the baseline value. After carpal tunnel release, there was no marked decrease in intraneural blood flow. This study demonstrated that the blood flow in the median nerve is reduced when Phalen's test is performed in vivo. Copyright 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Analysis of inorganic elements in blood of albino rabbit using NAA

    International Nuclear Information System (INIS)

    Metairon, Sabrina; Zamboni, Cibele B.; Medeiros, Ilca M.M.A.

    2009-01-01

    In this work Br, Cl, K and Na concentrations in albino rabbit blood were determinate using NAA. They are the first indicative interval for reference values in whole blood and they could be used for checking the clinical status of this specie when it will be used was animal model. The results when compared with human whole blood estimation suggest compatibility for Br, Cl and K considering 95% of confidence interval but, for Na the levels are altered, suggesting physiologic differences. (author)

  16. Recovery of Unrelated Donors of Peripheral Blood Stem Cells versus Recovery of Unrelated Donors of Bone Marrow: A Prespecified Analysis from the Phase III Blood and Marrow Transplant Clinical Trials Network Protocol 0201.

    Science.gov (United States)

    Burns, Linda J; Logan, Brent R; Chitphakdithai, Pintip; Miller, John P; Drexler, Rebecca; Spellman, Stephen; Switzer, Galen E; Wingard, John R; Anasetti, Claudio; Confer, Dennis L

    2016-06-01

    We report a comparison of time to recovery, side effects, and change in blood counts from baseline to after donation from unrelated donors who participated in the Blood and Marrow Transplant Clinical Trials Network phase III randomized, multicenter trial (0201) in which donor-recipient pairs were randomized to either peripheral blood stem cell (PBSC) or bone marrow (BM) donation. Of the entire cohort, 262 donated PBSC and 264 donated BM; 372 (71%) donors were from domestic and 154 (29%) were from international centers (145 German and 9 Canadian). PBSC donors recovered in less time, with a median time to recovery of 1 week compared with 2.3 weeks for BM donors. The number of donors reporting full recovery was significantly greater for donors of PBSC than of BM at 1, 2, and 3 weeks and 3 months after donation. Multivariate analysis showed that PBSC donors were more likely to recover at any time after donation compared with BM donors (hazard ratio, 2.08; 95% confidence interval [CI], 1.73 to 2.50; P donor and donation in more recent years. Donors of BM were more likely to report grades 2 to 4 skeletal pain, body symptoms, and fatigue at 1 week after donation. In logistic regression analysis of domestic donors only in which toxicities at peri-collection time points (day 5 filgrastim for PBSC donors and day 2 after collection of BM donors) could be analyzed, no variable was significantly associated with grades 2 to 4 skeletal pain, including product donated (BM versus PBSC; odds ratio, 1.13; 95% CI, .74 to 1.74; P = .556). Blood counts were affected by product donated, with greater mean change from baseline to after donation for white blood cells, neutrophils, mononuclear cells, and platelets in PBSC donors whereas BM donors experienced a greater mean change in hemoglobin. This analysis provided an enhanced understanding of donor events as product donated was independent of physician bias or donor preference. Copyright © 2016 The American Society for Blood and

  17. A meta-analysis of gene expression signatures of blood pressure and hypertension.

    Directory of Open Access Journals (Sweden)

    Tianxiao Huan

    2015-03-01

    Full Text Available Genome-wide association studies (GWAS have uncovered numerous genetic variants (SNPs that are associated with blood pressure (BP. Genetic variants may lead to BP changes by acting on intermediate molecular phenotypes such as coded protein sequence or gene expression, which in turn affect BP variability. Therefore, characterizing genes whose expression is associated with BP may reveal cellular processes involved in BP regulation and uncover how transcripts mediate genetic and environmental effects on BP variability. A meta-analysis of results from six studies of global gene expression profiles of BP and hypertension in whole blood was performed in 7017 individuals who were not receiving antihypertensive drug treatment. We identified 34 genes that were differentially expressed in relation to BP (Bonferroni-corrected p<0.05. Among these genes, FOS and PTGS2 have been previously reported to be involved in BP-related processes; the others are novel. The top BP signature genes in aggregate explain 5%-9% of inter-individual variance in BP. Of note, rs3184504 in SH2B3, which was also reported in GWAS to be associated with BP, was found to be a trans regulator of the expression of 6 of the transcripts we found to be associated with BP (FOS, MYADM, PP1R15A, TAGAP, S100A10, and FGBP2. Gene set enrichment analysis suggested that the BP-related global gene expression changes include genes involved in inflammatory response and apoptosis pathways. Our study provides new insights into molecular mechanisms underlying BP regulation, and suggests novel transcriptomic markers for the treatment and prevention of hypertension.

  18. Intelligent micro blood typing system using a fuzzy algorithm

    International Nuclear Information System (INIS)

    Kang, Taeyun; Cho, Dong-Woo; Lee, Seung-Jae; Kim, Yonggoo; Lee, Gyoo-Whung

    2010-01-01

    ABO typing is the first analysis performed on blood when it is tested for transfusion purposes. The automated machines used in hospitals for this purpose are typically very large and the process is complicated. In this paper, we present a new micro blood typing system that is an improved version of our previous system (Kang et al 2004 Trans. ASME, J. Manuf. Sci. Eng. 126 766, Lee et al 2005 Sensors Mater. 17 113). This system, fabricated using microstereolithography, has a passive valve for controlling the flow of blood and antibodies. The intelligent micro blood typing system has two parts: a single-line micro blood typing device and a fuzzy expert system for grading the strength of agglutination. The passive valve in the single-line micro blood typing device makes the blood stop at the entrance of a micro mixer and lets it flow again after the blood encounters antibodies. Blood and antibodies are mixed in the micro mixer and agglutination occurs in the chamber. The fuzzy expert system then determines the degree of agglutination from images of the agglutinated blood. Blood typing experiments using this device were successful, and the fuzzy expert system produces a grading decision comparable to that produced by an expert conducting a manual analysis

  19. Diagnostic prediction of renal failure from blood serum analysis by FTIR spectrometry and chemometrics

    Science.gov (United States)

    Khanmohammadi, Mohammdreza; Ghasemi, Keyvan; Garmarudi, Amir Bagheri; Ramin, Mehdi

    2015-02-01

    A new diagnostic approach based on Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) spectrometry and classification algorithm has been introduced which provides a rapid, reliable, and easy way to perform blood test for the diagnosis of renal failure. Blood serum samples from 35 renal failure patients and 40 healthy persons were analyzed by ATR-FTIR spectrometry. The resulting data was processed by Quadratic Discriminant Analysis (QDA) and QDA combined with simple filtered method. Spectroscopic studies were performed in 900-2000 cm-1 spectral region with 3.85 cm-1 data space. Results showed 93.33% and 100% of accuracy for QDA and filter-QDA models, respectively. In the first step, 30 samples were applied to construct the model. In order to modify the capability of QDA in prediction of test samples, filter-based feature selection methods were applied. It was found that the filtered spectra coupled with QDA could correctly predict the test samples in most of the cases.

  20. Unusual spontaneous cold auto-hemagglutination phenomenon in blood units stored under blood bank condition: A retrospective analysis

    Directory of Open Access Journals (Sweden)

    Sanmukh R Joshi

    2015-01-01

    Full Text Available Background: Cold agglutinins (CA are benign naturally occurring low titer autoantibodies present in most individuals. Those with moderate strength are found in infections, malignancies or autoimmune conditions with diagnostic importance. Aim: Present report deals with CA that brought spontaneous hemagglutination in blood units stored at 2-6°C. Study design: Over 32 months period between July 1993 and December 1995, blood units were inspected for spontaneous cold auto-hemagglutination (SpCA phenomenon. The plasma from these units was separated and investigated for serological specificity using in house red cell panel and standard serological methods. Results: Among 51,671 blood units, 112 units showed SpCA phenomenon. A rising trend seen in first half of study period significantly fell in remaining half. Specificities of the antibodies detected include anti-I (27, anti-i (53, anti-Pr (21 with remaining few being undetermined specificity. Absorption of serum using enzyme-treated red cells revealed a presence of anti-Pr among the cases, the two of which with new specificities that reacted preferentially with red cells from either new-born or adults and were tentatively named as anti-Pr Fetal and anti-Pr adult , respectively. While 9 cases showed optimum reaction at neutral pH of 7, 68 (62% cases reacted at pH 5.8 through 8.0, 28 (26% cases preferred an acidic pH 5.8 and 4 cases opted an alkaline pH 8. Of 28 cases with antibodies preferentially reacting in acidic medium, 17 (60% cases were anti-i and 7 (25% cases were anti-Pr. Conclusion: Unique SpCA phenomenon observed in blood units stored under blood bank conditions seems to be due to CA developed in response to vector-borne infectious agents. Majority of the cases displayed their specificities, otherwise are rare to be encountered.

  1. Analysis of blood donor pre-donation deferral in Dubai: characteristics and reasons

    Directory of Open Access Journals (Sweden)

    Al Shaer L

    2017-05-01

    Full Text Available Laila Al Shaer,1 Ranjita Sharma,2 Mahera AbdulRahman2 1College of Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai, UAE; 2Dubai Health Authority, Dubai, UAE Background: To ensure an adequate and safe blood supply, it is crucial to select suitable donors according to stringent eligibility criteria. Understanding the reasons for donor deferral can help in planning more efficient recruitment strategies and evaluating donor selection criteria. This study aims to define donor pre-donation deferral rates, causes of deferral, and characteristics of deferred donors in Dubai.Materials and methods: This retrospective study was conducted on all donors who presented for allogeneic blood donation between January 1, 2010, until June 30, 2013, in Dubai Blood Donation Centre, accredited by the American Association of Blood Banks. The donation and deferral data were analyzed to determine the demographic characteristics of accepted and deferred donors, and frequency analyses were also conducted.Results: Among 142,431 individuals presenting during the study period, 114,827 (80.6% were accepted for donation, and 27,604 (19.4% were deferred. The overall proportion of deferrals was higher among individuals less than 21 years old (35%, P<0.000, females (44% were deferred compared to 15% of males, P<0.0001, and first-time donors (22% were deferred vs 14% of repeat donors, P<0.0001. The main causes for a temporary deferral were low hemoglobin and high blood pressure.Discussion: The deferral rate among blood donors in Dubai is relatively high compared to the internationally reported rates. This rate was higher among first-time donors and females, with low hemoglobin as the major factor leading to a temporary deferral of donors. Strategies to mitigate deferral and improve blood donor retention are urged in Dubai to avoid additional stress on the blood supply. Keywords: blood donation, blood safety, donor deferral, selection criteria 

  2. Analysis of adverse events and predisposing factors in voluntary and replacement whole blood donors: A study from north India

    Directory of Open Access Journals (Sweden)

    Naveen Agnihotri

    2012-01-01

    Full Text Available Background: Lack of awareness and community motivation, compounded with fragmented blood transfusion services in our country, Often leads to shortage of blood. Donor recruitment and retention are essential for ensuring adequate blood supply. However, adverse events (AEs in donors have a negative impact on donor return. Aims and Objectives: The present study was aimed to assess the frequency of AEs in whole blood donors and analyze the predisposing factors for AEs. Material and Methods: The study was conducted on allogeneic whole blood donors over a period of 14 months, i.e., from January 2002 to February 2003. A total of 37,896 donors were monitored for any AEs: 22587 (59.6% were voluntary donors (VD and 15,309 (40.4% were replacement donors (RD. Results: Overall reaction rate was 2.5% with vasovagal reactions constituting 63.5% and hematomas 35.0% of all reactions. Vasovagal reactions showed a significant association with young age, lower weight, first time donation status, female gender, and nature of blood donation camps. Amongst male donors, RDs had more reactions (P=0.03 than VDs. Majority of donors (85% with vasovagal reactions admitted to some fear or anxiety prior to donation. Hematoma formation occurred significantly more when less trained staff performed phlebotomy. Conclusion: Donor safety is an essential prerequisite to increase voluntary blood donation. AE analysis helps in identifying the blood donors at risk of donor reactions and adopting appropriate donor motivational strategies, pre-donation counseling, and care during and after donation.

  3. Dried blood spot analysis of creatinine with LC-MS/MS in addition to immunosuppressants analysis.

    Science.gov (United States)

    Koster, Remco A; Greijdanus, Ben; Alffenaar, Jan-Willem C; Touw, Daan J

    2015-02-01

    In order to monitor creatinine levels or to adjust the dosage of renally excreted or nephrotoxic drugs, the analysis of creatinine in dried blood spots (DBS) could be a useful addition to DBS analysis. We developed a LC-MS/MS method for the analysis of creatinine in the same DBS extract that was used for the analysis of tacrolimus, sirolimus, everolimus, and cyclosporine A in transplant patients with the use of Whatman FTA DMPK-C cards. The method was validated using three different strategies: a seven-point calibration curve using the intercept of the calibration to correct for the natural presence of creatinine in reference samples, a one-point calibration curve at an extremely high concentration in order to diminish the contribution of the natural presence of creatinine, and the use of creatinine-[(2)H3] with an eight-point calibration curve. The validated range for creatinine was 120 to 480 μmol/L (seven-point calibration curve), 116 to 7000 μmol/L (1-point calibration curve), and 1.00 to 400.0 μmol/L for creatinine-[(2)H3] (eight-point calibration curve). The precision and accuracy results for all three validations showed a maximum CV of 14.0% and a maximum bias of -5.9%. Creatinine in DBS was found stable at ambient temperature and 32 °C for 1 week and at -20 °C for 29 weeks. Good correlations were observed between patient DBS samples and routine enzymatic plasma analysis and showed the capability of the DBS method to be used as an alternative for creatinine plasma measurement.

  4. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    Science.gov (United States)

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  5. Topical fibrin sealant versus intravenous tranexamic acid for reducing blood loss following total knee arthroplasty: A systematic review and meta-analysis.

    Science.gov (United States)

    Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo

    2016-08-01

    Efficacy and safety of topical application of a fibrin sealant (FS) compared with intravenous administration of tranexamic acid (TXA) for reducing blood loss after total knee arthroplasty (TKA) is controversial. We undertook a meta-analysis to compare the effects of topical application of FS or intravenous administration of TXA on blood loss after TKA. PubMed, Medline, Embase, Web of Science and the Cochrane Library were searched to identify studies comparing FS with TXA for TKA patients. The mean difference (MD) of blood loss, hemoglobin value, and odds ratios (ORs) of transfusion requirements and adverse events in FS and TXA groups were pooled throughout the study. Relevant data were analyzed using RevMan v5.3. Five studies involving 359 patients were included (181 FS vs. 178 TXA). TXA use had a significantly lower prevalence of blood transfusion (OR = 3.14; 95% confidence interval (CI), 1.67 to 5.90, P = 0.0004) and higher hemoglobin level (MD = -1.23; 95% CI, -2.19 to -0.27, P = 0.01) than FS in the early postoperative period. No significant difference was seen in total blood loss between the two groups (MD = 198.06; 95% CI, -267.45 to 663.57; P = 0.40). There were no significant differences in adverse events, superficial infections, or deep-vein thrombosis among study groups. Our meta-analysis suggests that intravenous administration of TXA for patients undergoing TKA may reduce blood-transfusion requirements and maintain higher hemoglobin levels compared with topical application of FS in the early postoperative period. There were no significant differences in total calculated blood loss and prevalence of complications between the two groups. However, owing to the variation of included studies, no firm conclusions can be drawn. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  6. High-throughput miRNA profiling of human melanoma blood samples

    Directory of Open Access Journals (Sweden)

    Rass Knuth

    2010-06-01

    Full Text Available Abstract Background MicroRNA (miRNA signatures are not only found in cancer tissue but also in blood of cancer patients. Specifically, miRNA detection in blood offers the prospect of a non-invasive analysis tool. Methods Using a microarray based approach we screened almost 900 human miRNAs to detect miRNAs that are deregulated in their expression in blood cells of melanoma patients. We analyzed 55 blood samples, including 20 samples of healthy individuals, 24 samples of melanoma patients as test set, and 11 samples of melanoma patients as independent validation set. Results A hypothesis test based approch detected 51 differentially regulated miRNAs, including 21 miRNAs that were downregulated in blood cells of melanoma patients and 30 miRNAs that were upregulated in blood cells of melanoma patients as compared to blood cells of healthy controls. The tets set and the independent validation set of the melanoma samples showed a high correlation of fold changes (0.81. Applying hierarchical clustering and principal component analysis we found that blood samples of melanoma patients and healthy individuals can be well differentiated from each other based on miRNA expression analysis. Using a subset of 16 significant deregulated miRNAs, we were able to reach a classification accuracy of 97.4%, a specificity of 95% and a sensitivity of 98.9% by supervised analysis. MiRNA microarray data were validated by qRT-PCR. Conclusions Our study provides strong evidence for miRNA expression signatures of blood cells as useful biomarkers for melanoma.

  7. The effect of ventricular assist devices on cerebral blood flow and blood pressure fractality

    International Nuclear Information System (INIS)

    Bellapart, Judith; Fraser, John F; Chan, Gregory S H; Tzeng, Yu-Chieh; Ainslie, Philip N; Dunster, Kimble R; Barnett, Adrian G; Boots, Rob

    2011-01-01

    Biological signals often exhibit self-similar or fractal scaling characteristics which may reflect intrinsic adaptability to their underlying physiological system. This study analysed fractal dynamics of cerebral blood flow in patients supported with ventricular assist devices (VAD) to ascertain if sustained modifications of blood pressure waveform affect cerebral blood flow fractality. Simultaneous recordings of arterial blood pressure and cerebral blood flow velocity using transcranial Doppler were obtained from five cardiogenic shock patients supported by VAD, five matched control patients and five healthy subjects. Computation of a fractal scaling exponent (α) at the low-frequency time scale by detrended fluctuation analysis showed that cerebral blood flow velocity exhibited 1/f fractal scaling in both patient groups (α = 0.95 ± 0.09 and 0.97 ± 0.12, respectively) as well as in the healthy subjects (α = 0.86 ± 0.07). In contrast, fluctuation in blood pressure was similar to non-fractal white noise in both patient groups (α = 0.53 ± 0.11 and 0.52 ± 0.09, respectively) but exhibited 1/f scaling in the healthy subjects (α = 0.87 ± 0.04, P < 0.05 compared with the patient groups). The preservation of fractality in cerebral blood flow of VAD patients suggests that normal cardiac pulsation and central perfusion pressure changes are not the integral sources of cerebral blood flow fractality and that intrinsic vascular properties such as cerebral autoregulation may be involved. However, there is a clear difference in the fractal scaling properties of arterial blood pressure between the cardiogenic shock patients and the healthy subjects

  8. Sensitive KIT D816V mutation analysis of blood as a diagnostic test in mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, Hanne; Bindslev-Jensen, Carsten

    2014-01-01

    The recent progress in sensitive KIT D816V mutation analysis suggests that mutation analysis of peripheral blood (PB) represents a promising diagnostic test in mastocytosis. However, there is a need for systematic assessment of the analytical sensitivity and specificity of the approach in order...... to establish its value in clinical use. We therefore evaluated sensitive KIT D816V mutation analysis of PB as a diagnostic test in an entire case-series of adults with mastocytosis. We demonstrate for the first time that by using a sufficiently sensitive KIT D816V mutation analysis, it is possible to detect...... the mutation in PB in nearly all adult mastocytosis patients. The mutation was detected in PB in 78 of 83 systemic mastocytosis (94%) and 3 of 4 cutaneous mastocytosis patients (75%). The test was 100% specific as determined by analysis of clinically relevant control patients who all tested negative. Mutation...

  9. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros.

    Science.gov (United States)

    Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N; Payne, Junaidi

    2013-02-01

    To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA(®) blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases.

  10. Comparative study of human blood Raman spectra and biochemical analysis of patients with cancer

    Science.gov (United States)

    Shamina, Lyudmila A.; Bratchenko, Ivan A.; Artemyev, Dmitry N.; Myakinin, Oleg O.; Moryatov, Alexander A.; Orlov, Andrey E.; Kozlov, Sergey V.; Zakharov, Valery P.

    2018-04-01

    In this study we measured spectral features of blood by Raman spectroscopy. Correlation of the obtained spectral data and biochemical studies results is investigated. Analysis of specific spectra allows for identification of informative spectral bands proportional to components whose content is associated with body fluids homeostasis changes at various pathological conditions. Regression analysis of the obtained spectral data allows for discriminating the lung cancer from other tumors with a posteriori probability of 88.3%. The potentiality of applying surface-enhanced Raman spectroscopy with utilized experimental setup for further studies of the body fluids component composition was estimated. The greatest signal amplification was achieved for the gold substrate with a surface roughness of 1 μm. In general, the developed approach of body fluids analysis provides the basis of a useful and minimally invasive method of pathologies screening.

  11. No impact of perioperative blood transfusion on prognosis after curative resection for hepatocellular carcinoma: a propensity score matching analysis.

    Science.gov (United States)

    Peng, T; Zhao, G; Wang, L; Wu, J; Cui, H; Liang, Y; Zhou, R; Liu, Z; Wang, Q

    2017-10-27

    The relationship between perioperative blood transfusion and long-term survival after curative resection for hepatocellular carcinoma (HCC) remains controversial. The aim of the present study was to investigate the impact of blood transfusion on the long-term prognosis of HCC patients. Patients with primary HCC who underwent a curative hepatectomy from 2003 to 2011 were enrolled and then retrospectively studied. The clinicopathologic characteristics between patients in the blood transfusion and non-transfusion groups were matched using a propensity score matching (PSM) analysis. Univariate and multivariate Cox regression analyses were used to identify whether perioperative blood transfusion affects long-term survival after resection for HCC. A total of 374 patients were enrolled and 113 patients received perioperative transfusions. The 1-, 3- and 5-year disease-free and overall survival rates of the entire cohort were 65.0, 37.3 and 23.9%, and 90.9, 70.7 and 57.5%, respectively. The disease-free and overall survival rates of the blood transfusion group were significantly worse than the disease-free and overall survival rates of the non-transfusion group in the entire cohort (p blood transfusion was not an independent predictor of disease-free and overall survival in the propensity-matched cohort (p = 0.154, p = 0.667). The present study demonstrates that perioperative blood transfusion has no impact on disease-free and overall survival after curative resection for HCC.

  12. Blood donor deferral: time for change? An evidence-based analysis

    Directory of Open Access Journals (Sweden)

    Borra V

    2016-05-01

    Full Text Available Vere Borra,1 Giovani Vandewalle,1 Hans Van Remoortel,1 Veerle Compernolle,1,2 Emmy De Buck,1 Philippe Vandekerckhove1–31Belgian Red Cross-Flanders, Mechelen, 2Faculty of Medicine, University of Ghent, Ghent, 3Department of Public Health and Primary Care, Faculty of Medicine, KU Leuven, Leuven, BelgiumAbstract: Donor selection remains an important part in the safety of the blood supply all over the world. Yet, donor deferral criteria seem to be strongly based on the precautionary principle protecting safety and quality, and on supply and expense considerations. This review therefore provides an overview of the available evidence on donor exclusion criteria, as well as on their cost-effectiveness, for the most frequent reasons of donor deferral in our region. PubMed was queried to retrieve primary research studies, systematic reviews, and health technology assessments (HTAs concerning donor exclusion criteria. With a similar approach, HTAs about the different blood-banking safety interventions were included. Reasons for donor deferral were recorded via the blood bank information system of the Belgian Red Cross-Flanders. Seven systematic reviews were identified: four on donor safety (hypotension, hypertension/type 2 diabetes, epilepsy, and higher age and three on recipient safety (hemochromatosis, men who have sex with men, and endoscopy. Forty-three low-quality observational studies were included, as well as 16 HTAs: three about donor exclusion criteria and 13 cost-utility analyses about blood-banking safety interventions. In general, the available evidence for deferral reasons was of low quality, and for 60% of the top 30 reasons for excluding donors, no evidence was found. Blood banking shows its unique position as many safety measures far exceed the normally accepted cost of €50,000/quality-adjusted life-years. The historical model based on the precautionary principle and on supply and expense considerations provides adequate supplies of

  13. Microarray analysis of peripheral blood lymphocytes from ALS patients and the SAFE detection of the KEGG ALS pathway

    Science.gov (United States)

    2011-01-01

    Background Sporadic amyotrophic lateral sclerosis (sALS) is a motor neuron disease with poorly understood etiology. Results of gene expression profiling studies of whole blood from ALS patients have not been validated and are difficult to relate to ALS pathogenesis because gene expression profiles depend on the relative abundance of the different cell types present in whole blood. We conducted microarray analyses using Agilent Human Whole Genome 4 × 44k Arrays on a more homogeneous cell population, namely purified peripheral blood lymphocytes (PBLs), from ALS patients and healthy controls to identify molecular signatures possibly relevant to ALS pathogenesis. Methods Differentially expressed genes were determined by LIMMA (Linear Models for MicroArray) and SAM (Significance Analysis of Microarrays) analyses. The SAFE (Significance Analysis of Function and Expression) procedure was used to identify molecular pathway perturbations. Proteasome inhibition assays were conducted on cultured peripheral blood mononuclear cells (PBMCs) from ALS patients to confirm alteration of the Ubiquitin/Proteasome System (UPS). Results For the first time, using SAFE in a global gene ontology analysis (gene set size 5-100), we show significant perturbation of the KEGG (Kyoto Encyclopedia of Genes and Genomes) ALS pathway of motor neuron degeneration in PBLs from ALS patients. This was the only KEGG disease pathway significantly upregulated among 25, and contributing genes, including SOD1, represented 54% of the encoded proteins or protein complexes of the KEGG ALS pathway. Further SAFE analysis, including gene set sizes >100, showed that only neurodegenerative diseases (4 out of 34 disease pathways) including ALS were significantly upregulated. Changes in UBR2 expression correlated inversely with time since onset of disease and directly with ALSFRS-R, implying that UBR2 was increased early in the course of ALS. Cultured PBMCs from ALS patients accumulated more ubiquitinated proteins

  14. Blood compatibility of magnesium and its alloys.

    Science.gov (United States)

    Feyerabend, Frank; Wendel, Hans-Peter; Mihailova, Boriana; Heidrich, Stefanie; Agha, Nezha Ahmad; Bismayer, Ulrich; Willumeit-Römer, Regine

    2015-10-01

    Blood compatibility analysis in the field of biomaterials is a highly controversial topic. Especially for degradable materials like magnesium and its alloys no established test methods are available. The purpose of this study was to apply advanced test methodology for the analysis of degrading materials to get a mechanistic insight into the corrosion process in contact with human blood and plasma. Pure magnesium and two magnesium alloys were analysed in a modified Chandler-Loop setup. Standard clinical parameters were determined, and a thorough analysis of the resulting implant surface chemistry was performed. The contact of the materials to blood evoked an accelerated inflammatory and cell-induced osteoconductive reaction. Corrosion products formed indicate a more realistic, in vivo like situation. The active regulation of corrosion mechanisms of magnesium alloys by different cell types should be more in the focus of research to bridge the gap between in vitro and in vivo observations and to understand the mechanism of action. This in turn could lead to a better acceptance of these materials for implant applications. The presented study deals with the first mechanistic insights during whole human blood contact and its influence on a degrading magnesium-based biomaterial. The combination of clinical parameters and corrosion layer analysis has been performed for the first time. It could be of interest due to the intended use of magnesium-based stents and for orthopaedic applications for clinical applications. An interest for the readers of Acta Biomaterialia may be given, as one of the first clinically approved magnesium-based devices is a wound-closure device, which is in direct contact with blood. Moreover, for orthopaedic applications also blood contact is of high interest. Although this is not the focus of the manuscript, it could help to rise awareness for potential future applications. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All

  15. Effect of ABO blood type on ovarian reserve in Chinese women.

    Science.gov (United States)

    Lin, Shengli; Li, Rong; Chi, Hongbin; Huang, Shuo; Zhang, Hua; Zheng, Xiaoying; Liu, Ping; Qiao, Jie

    2014-12-01

    To explore the effect of ABO blood type on ovarian reserve in Chinese women. Retrospective analysis. University-affiliated IVF center. The retrospective analysis involved 35,479 women who underwent in vitro fertilization and embryo transfer (IVF-ET) cycles between 2006 and 2012. None. The association between ABO blood types and diminished ovarian reserve (DOR). Among 35,479 Chinese women, 11,395 (32.12%) had blood type B, 10,583 (29.83%) had blood type O, 9,861 (27.79%) had blood type A, and 3,640 (10.26%) had blood type AB. There was a statistically significantly higher percentage of blood type O among those with follicle-stimulating hormone (FSH) levels ≤10 IU/L compared with those with FSH levels >10 IU/L. Conversely, among the women with DOR, there was statistically significantly higher percentage of those with blood types B and AB. Blood type A was not associated with DOR occurrence. Multivariate logistic regression analysis showed that blood type O was statistically significantly less often associated with DOR occurrence, whereas the B antigen (blood type B or AB) was statistically significantly associated with an increased risk of DOR. Our results have shown that there is an association between ABO blood type and DOR occurrence in Chinese women. Women with blood type O were statistically significantly less likely to have DOR, whereas those with B antigen (blood type B or AB) were statistically significantly more likely to have DOR. Blood type A was not associated with ovarian reserve. Copyright © 2014. Published by Elsevier Inc.

  16. Value of self-monitoring blood glucose pattern analysis in improving diabetes outcomes.

    Science.gov (United States)

    Parkin, Christopher G; Davidson, Jaime A

    2009-05-01

    Self-monitoring of blood glucose (SMBG) is an important adjunct to hemoglobin A1c (HbA1c) testing. This action can distinguish between fasting, preprandial, and postprandial hyperglycemia; detect glycemic excursions; identify and monitor resolution of hypoglycemia; and provide immediate feedback to patients about the effect of food choices, activity, and medication on glycemic control. Pattern analysis is a systematic approach to identifying glycemic patterns within SMBG data and then taking appropriate action based upon those results. The use of pattern analysis involves: (1) establishing pre- and postprandial glucose targets; (2) obtaining data on glucose levels, carbohydrate intake, medication administration (type, dosages, timing), activity levels and physical/emotional stress; (3) analyzing data to identify patterns of glycemic excursions, assessing any influential factors, and implementing appropriate action(s); and (4) performing ongoing SMBG to assess the impact of any therapeutic changes made. Computer-based and paper-based data collection and management tools can be developed to perform pattern analysis for identifying patterns in SMBG data. This approach to interpreting SMBG data facilitates rational therapeutic adjustments in response to this information. Pattern analysis of SMBG data can be of equal or greater value than measurement of HbA1c levels. 2009 Diabetes Technology Society.

  17. [Comparative analysis on the biological basis of blood stasis syndrome induced by qi-stagnation and qi-deficiency in patients with unstable angina pectoris].

    Science.gov (United States)

    Ren, Jian-xun; Liu, Jian-xun; Lin, Cheng-ren

    2010-04-01

    To comparatively analyse the objective characteristics of different syndrome types of qi-disturbance-induced blood stasis syndrome (QDBS) in the pathogenetic evolution of unstable angina coronary heart disease (UA-CHD). Seventy-eight patients with UA-CHD of QDBS were differentiated into 2 groups: 55 in the qi-deficiency-induced blood-stasis syndrome group (A) and 23 in the qi-stagnation-induced blood-stasis syndrome group (B). The comparative analysis on them was carried out through comparing their blood pressure, glucose and lipid metabolisms, coagulation function, thyroid function and inflammation reaction changes, etc. In the pathogenetic process of qi-disturbance induced blood stasis, the initiating age, levels of HbA1c, TSH, PT and APTT between the two groups were significantly different (P emotional stress is possibly the essence of qi-stagnation induced blood stasis syndrome.

  18. Appropriate Handling, Processing and Analysis of Blood Samples Is Essential to Avoid Oxidation of Vitamin C to Dehydroascorbic Acid.

    Science.gov (United States)

    Pullar, Juliet M; Bayer, Simone; Carr, Anitra C

    2018-02-11

    Vitamin C (ascorbate) is the major water-soluble antioxidant in plasma and its oxidation to dehydroascorbic acid (DHA) has been proposed as a marker of oxidative stress in vivo. However, controversy exists in the literature around the amount of DHA detected in blood samples collected from various patient cohorts. In this study, we report on DHA concentrations in a selection of different clinical cohorts (diabetes, pneumonia, cancer, and critically ill). All clinical samples were collected into EDTA anticoagulant tubes and processed at 4 °C prior to storage at -80 °C for subsequent analysis by HPLC with electrochemical detection. We also investigated the effects of different handling and processing conditions on short-term and long-term ascorbate and DHA stability in vitro and in whole blood and plasma samples. These conditions included metal chelation, anticoagulants (EDTA and heparin), and processing temperatures (ice, 4 °C and room temperature). Analysis of our clinical cohorts indicated very low to negligible DHA concentrations. Samples exhibiting haemolysis contained significantly higher concentrations of DHA. Metal chelation inhibited oxidation of vitamin C in vitro, confirming the involvement of contaminating metal ions. Although EDTA is an effective metal chelator, complexes with transition metal ions are still redox active, thus its use as an anticoagulant can facilitate metal ion-dependent oxidation of vitamin C in whole blood and plasma. Handling and processing blood samples on ice (or at 4 °C) delayed oxidation of vitamin C by a number of hours. A review of the literature regarding DHA concentrations in clinical cohorts highlighted the fact that studies using colourimetric or fluorometric assays reported significantly higher concentrations of DHA compared to those using HPLC with electrochemical detection. In conclusion, careful handling and processing of samples, combined with appropriate analysis, is crucial for accurate determination of ascorbate

  19. A high plasma: red blood cell transfusion ratio during liver transplantation is associated with decreased blood utilization.

    Science.gov (United States)

    Pagano, M B; Metcalf, R A; Hess, J R; Reyes, J; Perkins, J D; Montenovo, M I

    2018-04-01

    During massive transfusion, the volume ratio of administered plasma (PL Vol) to red blood cell (RBC Vol) appears to be associated with reduced blood utilization and improved survival. The aim of this study was to evaluate the optimal component ratio in the setting of liver transplantation. This is a retrospective chart review of patients who underwent liver transplantation and received at least 500 ml of red blood cells from January 2013 through December 2015. Kernel smoothing analysis determined the proper component ratios to evaluate were a ≥0·85:1 ratio (high) to a ≤0·85:1 ratio (low). Two groups, plasma volume to RBC volume (PL Vol/RBC Vol) and plasma contained in the platelet units added to the plasma calculation [PL + PLT (platelet)] Vol/RBC Vol, were used to evaluate the component ratios. A total of 188 patients were included in the analysis. In the PL Vol/RBC Vol evaluation, a low ratio revealed that 1238 ml (977-1653 ml) (P ratio, in the univariable and multivariable analysis, respectively. In the PL +PLT Vol/RBC Vol evaluation, a low ratio used 734 ml (193-1275) (P = 0·008) and 886 ml (431-1340) (P ratio in the univariable and multivariable analysis, respectively. In patients undergoing liver transplantation, the transfusion of plasma to RBC ratio ≥0·85 was associated with decreased need of RBC transfusions. © 2018 International Society of Blood Transfusion.

  20. Response of selenium changes in blood using cyclic activation analysis

    International Nuclear Information System (INIS)

    Spyrou, N.M.; Akanle, O.B.; Damyanova, A.A.

    1986-01-01

    A study was undertaken to investigate the response of selenium uptake and washout in whole blood and its components in healthy subjects, aged 20 to 30 yr, who were given selenium as a supplement to their usual diet, in the form of a yeast tablet (200 mg) containing 100 μg of the element together with vitamins A, C, and E (natural). Selenium has gained worldwide interest not only as an essential trace element but as a potent modifier of environmental hazards and as a naturally occurring toxicant. It is important therefore to investigate the character and the degree of the changes in healthy people on selenium supplementation. Cyclic activation analysis was used for the determination of selenium concentration through the detection of /sup 77m/Se (17.5 s), because of the increased sensitivity of the method and the large number of samples involved

  1. Associations between postprandial insulin and blood glucose responses, appetite sensations and energy intake in normal weight and overweight individuals: a meta-analysis of test meal studies

    DEFF Research Database (Denmark)

    Flint, Anne; Gregersen, Nikolaj T.; Gluud, Lise L.

    2007-01-01

    is unclear whether postprandial blood glucose or insulin exerts a regulatory function in short-term appetite regulation in humans. The aim of this study was to investigate, by use of meta-analysis, the role of blood glucose and insulin in short-term appetite sensation and energy intake (EI......) in normal weight and overweight participants. Data from seven test meal studies were used, including 136 healthy participants (ALL) (92 normal weight (NW) and 44 overweight or obese (OW)). All meals were served as breakfasts after an overnight fast, and appetite sensations and blood samples were obtained...... frequently in the postprandial period. Finally, an ad libitum lunch was served. Data were analysed by fixed effects study level (SL) meta-regression analysis and individual participant data (IPD) regression analysis, using STATA software. In SL analysis, postprandial insulin response was associated...

  2. The effects of intraoperative autologous whole blood sequestration on the need for transfusion of allogenic blood and blood products in coronary bypass operations.

    Science.gov (United States)

    Canver, C C; Kroncke, G M; Nichols, R D; Murray, E L; Mentzer, R M

    1995-10-01

    We investigated the effect of intraoperative autologous blood sequestration (IABS), an old blood conservation method, on transfusion requirements for homologous packed red blood cells (PRBC), platelets, and fresh frozen plasma (FFP) for patients undergoing coronary bypass surgery. This non-randomized retrospective study involved 204 patients who underwent isolated primary coronary artery bypass grafting (CABG). In 140 patients (IABS Group), autologous heparinized whole blood was removed intraoperatively via aortic cannula before bypass and retransfused at the conclusion of extracorporeal circulation. In 64 control patients, no IABS was performed. Demographic characteristics and operative and perioperative variables for both groups were similar (p > 0.05). In 140 patients, the mean sequestered blood volume was 1430 ml (range = 700-2100 ml). The banked PRBC requirement during hospitalization was 1.91 units in the No IABS Group and 2.25 units for the IABS Group (p = 0.2957). The need for platelet transfusion was 3.06 units in the No IABS Group and 1.09 units in the IABS Group (p = 0.0003). In the No IABS Group, 1.31 units of FFP was transfused and in the IABS Group, 0.49 units was transfused (p = 0.0004). To identify possible confounding factors, we performed a multivariate Poisson regression analysis for the 22 patient variables by a forward stepwise procedure. Regression analysis indicated that IABS did not alter the need for PRBC transfusion (p = 0.6194) but adjusted differences did confirm that IABS was associated with decreased need for transfusion of platelets and FFP (p = 0.0001 and p = 0.0002, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Influence of ABO blood group on sports performance.

    Science.gov (United States)

    Lippi, Giuseppe; Gandini, Giorgio; Salvagno, Gian Luca; Skafidas, Spyros; Festa, Luca; Danese, Elisa; Montagnana, Martina; Sanchis-Gomar, Fabian; Tarperi, Cantor; Schena, Federico

    2017-06-01

    Despite being a recessive trait, the O blood group is the most frequent worldwide among the ABO blood types. Since running performance has been recognized as a major driver of evolutionary advantage in humans, we planned a study to investigate whether the ABO blood group may have an influence on endurance running performance in middle-aged recreational athletes. The study population consisted of 52 recreational, middle-aged, Caucasian athletes (mean age: 49±13 years, body mass index, 23.4±2.3 kg/m 2 ), regularly engaged in endurance activity. The athletes participated to a scientific event called "Run for Science" (R4S), entailing the completion of a 21.1 km (half-marathon) run under competing conditions. The ABO blood type status of the participants was provided by the local Service of Transfusion Medicine. In univariate analysis, running performance was significantly associated with age and weekly training, but not with body mass index. In multiple linear regression analysis, age and weekly training remained significantly associated with running performance. The ABO blood group status was also found to be independently associated with running time, with O blood type athletes performing better than those with non-O blood groups. Overall, age, weekly training and O blood group type explained 62.2% of the total variance of running performance (age, 41.6%; training regimen, 10.5%; ABO blood group, 10.1%). The results of our study show that recreational athletes with O blood group have better endurance performance compared to those with non-O blood group types. This finding may provide additional support to the putative evolutionary advantages of carrying the O blood group.

  4. Structural analysis of the RH-like blood group gene products in nonhuman primates

    Energy Technology Data Exchange (ETDEWEB)

    Salvignol, I. [Centre Regional de Transfusion Sanguine, Toulouse (France); Calvas, P.; Blancher, A. [Universitaire d`Immunogenetique moleculaire, Toulouse (France); Socha, W.W. [University Medical Center, New York, NY (United States); Colin, Y.; Le Van Kim, C.; Bailly, P.; Cartron, J.P. [Institut National de la Transfusion Sanguine, Paris (France); Ruffie, J.; Blancher, A. [College de France, Paris (France)

    1995-03-01

    Rh-related transcripts present in bone marrow samples from several species of nonhuman primates (chimpanzee, gorilla, gibbon, crab-eating macaque) have been amplified by RT-polymerase chain reaction using primers deduced from the sequence of human RH genes. Nucleotide sequence analysis of the nonhuman transcripts revealed a high degree of similarity to human blood group Rh sequences, suggesting a great conservation of the RH genes throughout evolution. Full-length transcripts, potentially encoding 417 amino acid long proteins homologous to Rh polypeptides, were characterized, as well as mRNA isoforms which harbored nucleotide deletions or insertions and potentially encode truncated proteins. Proteins of 30-40,000 M{sub r}, immunologically related to human Rh proteins, were detected by western blot analysis with antipeptide antibodies, indicating that Rh-like transcripts are translated into membrane proteins. Comparison of human and nonhuman protein sequences was pivotal in clarifying the molecular basis of the blood group C/c polymorphism, showing that only the Pro103Ser substitution was correlated with C/c polymorphism. In addition, it was shown that a proline residue at position 102 was critical in the expression of C and c epitopes, most likely by providing an appropriate conformation of Rh polypeptides. From these data a phylogenetic reconstruction of the RH locus evolution has been calculated from which an unrooted phylogenetic tree could be proposed, indicating that African ape Rh-like genes would be closer to the human RhD gene than to the human RhCE gene. 55 refs., 4 figs., 1 tab.

  5. Implementation of laser speckle contrast analysis as connection kit for mobile phone for assessment of skin blood flow

    Science.gov (United States)

    Jakovels, Dainis; Saknite, Inga; Spigulis, Janis

    2014-05-01

    Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new implementations as connection kits for mobile phones thus offering low cost screening devices. In this work we demonstrate simple implementation of LASCA imaging technique as connection kit for mobile phone for primary low-cost assessment of skin blood flow. Stabilized 650 nm and 532 nm laser diode modules were used for LASCA illumination. Dual wavelength illumination could provide additional information about skin hemoglobin and oxygenation level. The proposed approach was tested for arterial occlusion and heat test. Besides, blood flow maps of injured and provoked skin were demonstrated.

  6. Changing trends in blood transfusion: an analysis of 244,013 hospitalizations.

    Science.gov (United States)

    Shehata, Nadine; Forster, Alan; Lawrence, Nadine; Rothwell, Deanna M; Fergusson, Dean; Tinmouth, Alan; Wilson, Kumanan

    2014-10-01

    Identifying recipients of blood transfusion and the trends in transfusion are needed to properly identify and target clinical services in need of patient blood management strategies. We determined the proportion of admissions to each clinical service that received blood, the mean number of units utilized, and the 5-year trends in utilization. We used a large administrative database, a repository for three campuses of one university-affiliated hospital, and included all adults that were hospitalized from November 1, 2006, to June 2012. The data were analyzed as the proportion of admissions transfused and the mean number units transfused per admission. Of 244,013 hospitalizations, 38,265 received at least one transfusion (29,165 for red blood cells [RBCs], 6760 for plasma, and 5795 for platelets [PLTs]). Although there has been a gradual decrease in the mean number of RBCs transfused (percent change, -9.8%; p = 0.002), an increase in the proportion of admissions receiving RBCs (17.2% increase, p conservation strategies. © 2014 AABB.

  7. Distribution of trace elements in whole blood of Syrian lymphomas patients using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Bakir, M. A.; Serhil, A.; Mohammad, A.; Habil, K.

    2013-12-01

    In recent years, there had been much interest in the concentrations of trace metals occurring in human and animal tissues and in the manner in which these concentrations may alter in malignant and other diseases. Neutron activation analysis is consider one of several methods that have been described for the determination of trace elements in biological materials. This method possesses the sensitivity and specificity necessary for the estimation at the concentrations existing naturally in most tissues, particularly when only small samples are available for analysis. The purpose of this study was to compare blood concentrations of trace elements Co, Cr, Fe, Rb, Sc, Se, Th, and Zn of lymphomas Syrian patients with those of healthy volunteers. Also, determine the relationships between trace elements concentration and the histological type of lymphomas. The blood samples were collected from 39 healthy volunteers and 49 patients with histologically confirmed lymphomas (29 Hodgkin's HL and 20 non-Hodgkin's lymphomas NHL), and analyzed to obtain the concentration of the trace elements in blood. Then, comparison between the healthy volunteers and lymphomas patients (both HL and NHL) was made to elucidate differences of the concentration distributions of the elements in blood. However, statistical analysis using Student's t test revealed significantly high concentrations of Co, Cr, Sc, and Th in lymphoma patients. Whereas Fe and Rb were found significantly decreased in lymphomas patient comparing to control group. Increasing or decreasing concentrations of Se and Zn in lymphoma patients was found not significant. Comparison between the healthy volunteers and non-Hodgkin's lymphomas patients reveled that Co, Cr, Sc, and Th were significantly elevated whereas, Rb only one trace element was decreased and all change in concentrations (elevating or decreasing) of Se and Zn were not significant. Comparison between the healthy volunteers and Hodgkin

  8. Blood specimen labelling errors: Implications for nephrology nursing practice.

    Science.gov (United States)

    Duteau, Jennifer

    2014-01-01

    Patient safety is the foundation of high-quality health care, as recognized both nationally and worldwide. Patient blood specimen identification is critical in ensuring the delivery of safe and appropriate care. The practice of nephrology nursing involves frequent patient blood specimen withdrawals to treat and monitor kidney disease. A critical review of the literature reveals that incorrect patient identification is one of the major causes of blood specimen labelling errors. Misidentified samples create a serious risk to patient safety leading to multiple specimen withdrawals, delay in diagnosis, misdiagnosis, incorrect treatment, transfusion reactions, increased length of stay and other negative patient outcomes. Barcode technology has been identified as a preferred method for positive patient identification leading to a definitive decrease in blood specimen labelling errors by as much as 83% (Askeland, et al., 2008). The use of a root cause analysis followed by an action plan is one approach to decreasing the occurrence of blood specimen labelling errors. This article will present a review of the evidence-based literature surrounding blood specimen labelling errors, followed by author recommendations for completing a root cause analysis and action plan. A failure modes and effects analysis (FMEA) will be presented as one method to determine root cause, followed by the Ottawa Model of Research Use (OMRU) as a framework for implementation of strategies to reduce blood specimen labelling errors.

  9. Effect of Childhood Obesity Prevention Programs on Blood Pressure: A Systematic Review and Meta-Analysis

    Science.gov (United States)

    Cai, Li; Wu, Yang; Wilson, Renee F.; Segal, Jodi B.; Kim, Miyong T.; Wang, Youfa

    2015-01-01

    Background Childhood overweight and obesity are associated with elevated blood pressure (BP). However, little is known about how childhood obesity lifestyle prevention programs affect BP. We assessed the effects of childhood obesity prevention programs on BP in children in developed countries. Methods and Results We searched databases up to April 22, 2013 for relevant randomized controlled trials, quasi-experimental studies, and natural experiments. Studies were included if they applied a diet and/or physical activity intervention(s) and were followed for ≥1 year (or ≥ 6 months for school-based intervention studies); they were excluded if they targeted only overweight/obese subjects or those with a medical condition. In our meta-analysis, intervention effects were calculated for systolic blood pressure (SBP) and diastolic blood pressure (DBP) using weighted random effects models. Of the 23 included intervention studies (involving 18,925 participants), 21 involved a school setting. Our meta-analysis included 19 studies reporting on SBP and 18 on DBP. The pooled intervention effect was −1.64 mmHg (95% CI: -2.56, −0.71; P=0.001) for SBP and -1.44 mmHg (95% CI: −2.28, −0.60; P=0.001) for DBP. The combined diet and physical activity interventions led to a significantly greater reduction in both SBP and DBP than the diet-only or physical activity-only intervention. Thirteen interventions (46%) had a similar effect on both adiposity-related outcomes and BP; while 11 interventions (39%) showed a significant desirable effect on BP, but not on adiposity-related outcomes. Conclusions Obesity prevention programs have a moderate effect on reducing BP and those targeting at both diet and physical activity seem to be more effective. PMID:24552832

  10. Operative time, blood loss, hemoglobin drop, blood transfusion, and hospital stay in orthognathic surgery.

    Science.gov (United States)

    Salma, Ra'ed Ghaleb; Al-Shammari, Fahad Mohammed; Al-Garni, Bishi Abdullah; Al-Qarzaee, Mohammed Abdullah

    2017-06-01

    This study was conducted to evaluate the operative time, blood loss, hemoglobin drop, blood transfusion, and length of hospital stay in orthognathic surgery. A 10-year retrospective analysis was performed on patients who underwent bilateral sagittal split osteotomy (with or without genioplasty), Le Fort I osteotomy (with or without genioplasty), or any combination of these procedures. A total of 271 patients were included. The age range was 17 to 49 years, with a mean age of 24.13 ± 4.51 years. Approximately 62% of patients underwent double-jaw surgery. The most common procedure was bilateral sagittal split with Le Fort I (37%). The average operative time was 3.96 ± 1.25 h. The mean estimated blood loss was 345.2 ± 149.74 mL. Approximately 9% of patients received intraoperative blood transfusion. The mean hemoglobin drop in the non-transfusion cases was 2.38 ± 0.89 g/dL. The mean postoperative hospital stay was 1.85 ± 0.83 days. Only one patient was admitted to the ICU for one night. In orthognathic surgery, blood loss is relatively minor, blood transfusion is frequent, and ICU admission is unlikely. Operative time, blood loss, blood transfusion, and the complexity of the surgical procedure can significantly increase the length of hospital stay. Males may bleed more than females in orthognathic surgery. Hemoglobin drop can be overestimated due to hemodilution in orthognathic surgery, which may influence the decision to use blood transfusion.

  11. Qualitative Analysis of Primary Fingerprint Pattern in Different Blood Group and Gender in Nepalese

    Directory of Open Access Journals (Sweden)

    Sudikshya KC

    2018-01-01

    Full Text Available Dermatoglyphics, the study of epidermal ridges on palm, sole, and digits, is considered as most effective and reliable evidence of identification. The fingerprints were studied in 300 Nepalese of known blood groups of different ages and classified into primary patterns and then analyzed statistically. In both sexes, incidence of loops was highest in ABO blood group and Rh +ve blood types, followed by whorls and arches, while the incidence of whorls was highest followed by loops and arches in Rh −ve blood types. Loops were higher in all blood groups except “A –ve” and “B –ve” where whorls were predominant. The fingerprint pattern in Rh blood types of blood group “A” was statistically significant while in others it was insignificant. In middle and little finger, loops were higher whereas in ring finger whorls were higher in all blood groups. Whorls were higher in thumb and index finger except in blood group “O” where loops were predominant. This study concludes that distribution of primary pattern of fingerprint is not related to gender and blood group but is related to individual digits.

  12. Effect of hematocrit and systolic blood pressure on cerebral blood flow in newborn infants

    International Nuclear Information System (INIS)

    Younkin, D.P.; Reivich, M.; Jaggi, J.L.; Obrist, W.D.; Delivoria-Papadopoulos, M.

    1987-01-01

    The effects of hematocrit and systolic blood pressure on cerebral blood flow were measured in 15 stable, low birth weight babies. CBF was measured with a modification of the xenon-133 ( 133 Xe) clearance technique, which uses an intravenous bolus of 133 Xe, an external chest detector to estimate arterial 133 Xe concentration, eight external cranial detectors to measure cephalic 133 Xe clearance curves, and a two-compartmental analysis of the cephalic 133 Xe clearance curves to estimate CBF. There was a significant inverse correlation between hematocrit and CBF, presumably due to alterations in arterial oxygen content and blood viscosity. Newborn CBF varied independently of systolic blood pressure between 60 and 84 mm Hg, suggesting an intact cerebrovascular autoregulatory mechanism. These results indicate that at least two of the factors that affect newborn animal CBF are operational in human newborns and may have important clinical implications

  13. Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree

    International Nuclear Information System (INIS)

    Molloi, Sabee; Wong, Jerry T

    2007-01-01

    The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions (30-70% diameter stenosis) where it is difficult to determine whether a particular lesion is the cause of ischaemia. Therefore, a functional measure of stenosis severity is needed. The purpose of this study is to determine whether the expected maximum coronary blood flow in an arterial tree is predictable from its sum of arterial branch lengths or lumen volume. Using a computer model of a porcine coronary artery tree, an analysis of blood flow distribution was conducted through a network of millions of vessels that included the entire coronary artery tree down to the first capillary branch. The flow simulation results show that there is a linear relationship between coronary blood flow and the sum of its arterial branch lengths. This relationship holds over the entire arterial tree. The flow simulation results also indicate that there is a 3/4 er relation between coronary blood flow (Q) and the sum of its arterial lumen volume (V). Moreover, there is a linear relationship between normalized Q and normalized V raised to a power of 3/4 over the entire arterial tree. These results indicate that measured arterial branch lengths or lumen volumes can be used to predict the expected maximum blood flow in an arterial tree. This theoretical maximum blood flow, in conjunction with an angiographically measured blood flow, can potentially be used to calculate fractional flow reserve based entirely on angiographic data

  14. Dried blood spot analysis of (+) and (-) darunavir enantiomers on immobilized amylose tris-(3, 5-dimethylphenylcarbamate) LC and its application to pharmacokinetics.

    Science.gov (United States)

    Ramisetti, Nageswara Rao; Arnipalli, Manikanta Swamy; Nimmu, Narendra Varma

    2015-12-01

    Dried blood spot analysis is an innovative novel blood sampling technique gaining interest in drug discovery and development processes owing to its inherent advantages over the conventional whole blood, plasma or serum sample collection. The present manuscript describes the development and validation of a highly sensitive and precise method of evaluation of pharmacokinetics of (+) and (-) darunavir enantiomers on rat dried blood spots. The enantiomers on rat dried blood spots were extracted into methanol and separated by LC on a Chiralpak IA column using hexane and ethanol containing 0.1% DEA (75:25, v/v) as a mobile phase at 20°C; both the enantiomers were detected at 266 nm using a photodiode array detector. The method was validated in terms of selectivity, linearity, accuracy, precision and stability as per the US Food and Drug and Administration guidelines. The hematocrit effect on extraction recovery was evaluated and the mean recoveries of (-) and (+) enantiomers of darunavir from dried blood spots were found to be 85.76 and 88.91% respectively. The intra- and inter-day precision and accuracy were 3.1-8.4 and 0.8-4.8% respectively. The developed method was successfully applied to a pharmacokinetic study of (+) and (-) enantiomers of darunavir on rat dried blood spots. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Automated measurement and classification of pulmonary blood-flow velocity patterns using phase-contrast MRI and correlation analysis.

    Science.gov (United States)

    van Amerom, Joshua F P; Kellenberger, Christian J; Yoo, Shi-Joon; Macgowan, Christopher K

    2009-01-01

    An automated method was evaluated to detect blood flow in small pulmonary arteries and classify each as artery or vein, based on a temporal correlation analysis of their blood-flow velocity patterns. The method was evaluated using velocity-sensitive phase-contrast magnetic resonance data collected in vitro with a pulsatile flow phantom and in vivo in 11 human volunteers. The accuracy of the method was validated in vitro, which showed relative velocity errors of 12% at low spatial resolution (four voxels per diameter), but was reduced to 5% at increased spatial resolution (16 voxels per diameter). The performance of the method was evaluated in vivo according to its reproducibility and agreement with manual velocity measurements by an experienced radiologist. In all volunteers, the correlation analysis was able to detect and segment peripheral pulmonary vessels and distinguish arterial from venous velocity patterns. The intrasubject variability of repeated measurements was approximately 10% of peak velocity, or 2.8 cm/s root-mean-variance, demonstrating the high reproducibility of the method. Excellent agreement was obtained between the correlation analysis and radiologist measurements of pulmonary velocities, with a correlation of R2=0.98 (P<.001) and a slope of 0.99+/-0.01.

  16. Impact of perioperative blood pressure variability on health resource utilization after cardiac surgery: an analysis of the ECLIPSE trials.

    Science.gov (United States)

    Aronson, Solomon; Levy, Jerrold H; Lumb, Philip D; Fontes, Manuel; Wang, Yamei; Crothers, Tracy A; Sulham, Katherine A; Navetta, Marco S

    2014-06-01

    To examine the impact of blood pressure control on hospital health resource utilization using data from the ECLIPSE trials. Post-hoc analysis of data from 3 prospective, open-label, randomized clinical trials (ECLIPSE trials). Sixty-one medical centers in the United States. Patients 18 years or older undergoing cardiac surgery. Clevidipine was compared with nitroglycerin, sodium nitroprusside, and nicardipine. The ECLIPSE trials included 3 individual randomized open-label studies comparing clevidipine to nitroglycerin, sodium nitroprusside, and nicardipine. Blood pressure control was assessed as the integral of the cumulative area under the curve (AUC) outside specified systolic blood pressure ranges, such that lower AUC represents less variability. This analysis examined surgery duration, time to extubation, as well as intensive care unit (ICU) and hospital length of stay (LOS) in patients with AUC≤10 mmHg×min/h compared to patients with AUC>10 mmHg×min/h. One thousand four hundred ten patients were included for analysis; 736 patients (52%) had an AUC≤10 mmHg×min/h, and 674 (48%) had an AUC>10 mmHg×min/h. The duration of surgery and ICU LOS were similar between groups. Time to extubation and postoperative LOS were both significantly shorter (p = 0.05 and pAUC≤10. Multivariate analysis demonstrates AUC≤10 was significantly and independently associated with decreased time to extubation (hazard ratio 1.132, p = 0.0261) and postoperative LOS (hazard ratio 1.221, p = 0.0006). Based on data derived from the ECLIPSE studies, increased perioperative BP variability is associated with delayed time to extubation and increased postoperative LOS. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Analysis of blood donor pre-donation deferral in Dubai: characteristics and reasons.

    Science.gov (United States)

    Al Shaer, Laila; Sharma, Ranjita; AbdulRahman, Mahera

    2017-01-01

    To ensure an adequate and safe blood supply, it is crucial to select suitable donors according to stringent eligibility criteria. Understanding the reasons for donor deferral can help in planning more efficient recruitment strategies and evaluating donor selection criteria. This study aims to define donor pre-donation deferral rates, causes of deferral, and characteristics of deferred donors in Dubai. This retrospective study was conducted on all donors who presented for allogeneic blood donation between January 1, 2010, until June 30, 2013, in Dubai Blood Donation Centre, accredited by the American Association of Blood Banks. The donation and deferral data were analyzed to determine the demographic characteristics of accepted and deferred donors, and frequency analyses were also conducted. Among 142,431 individuals presenting during the study period, 114,827 (80.6%) were accepted for donation, and 27,604 (19.4%) were deferred. The overall proportion of deferrals was higher among individuals less than 21 years old (35%, P Dubai is relatively high compared to the internationally reported rates. This rate was higher among first-time donors and females, with low hemoglobin as the major factor leading to a temporary deferral of donors. Strategies to mitigate deferral and improve blood donor retention are urged in Dubai to avoid additional stress on the blood supply.

  18. Cinnamomum zeylanicum extract on the radiolabelling of blood constituents and the morphometry of red blood cells: In vitro assay

    International Nuclear Information System (INIS)

    Benarroz, M.O.; Fonseca, A.S.; Rocha, G.S.; Frydman, J.N.G.; Rocha, V.C.; Pereira, M.O.

    2008-01-01

    Effects of Cinnamomum zeylanicum (cinnamon) on the labelling of blood constituents with technetium-99 m( 99m Tc) and on the morphology of red blood cells were studied. Blood samples from Wistar rats were incubated with cinnamon extract for 1hour or with 0.9% NaCl, as control. Labelling of blood constituents with 99m Tc was performed. Plasma (P) and blood cells (BC), soluble (SF-P and SF-BC) and insoluble (IF-P and IF-BC) fractions were separated. The radioactivity in each fraction was counted and the percentage of radioactivity incorporated (%ATI) was calculated. Blood smears were prepared, fixed, stained and the qualitative and quantitative morphological analysis of the red blood cells was evaluated. The data showed that the cinnamon extract decreased significantly (p 99m Tc, and although our results were obtained with animals, precaution is suggested in interpretations of nuclear medicine examinations involving the labelling of blood constituents in patients who are using cinnamon

  19. Interactions between cadmium and decabrominated diphenyl ether on blood cells count in rats—Multiple factorial regression analysis

    International Nuclear Information System (INIS)

    Curcic, Marijana; Buha, Aleksandra; Stankovic, Sanja; Milovanovic, Vesna; Bulat, Zorica; Đukić-Ćosić, Danijela; Antonijević, Evica; Vučinić, Slavica; Matović, Vesna; Antonijevic, Biljana

    2017-01-01

    The objective of this study was to assess toxicity of Cd and BDE-209 mixture on haematological parameters in subacutely exposed rats and to determine the presence and type of interactions between these two chemicals using multiple factorial regression analysis. Furthermore, for the assessment of interaction type, an isobologram based methodology was applied and compared with multiple factorial regression analysis. Chemicals were given by oral gavage to the male Wistar rats weighing 200–240 g for 28 days. Animals were divided in 16 groups (8/group): control vehiculum group, three groups of rats were treated with 2.5, 7.5 or 15 mg Cd/kg/day. These doses were chosen on the bases of literature data and reflect relatively high Cd environmental exposure, three groups of rats were treated with 1000, 2000 or 4000 mg BDE-209/kg/bw/day, doses proved to induce toxic effects in rats. Furthermore, nine groups of animals were treated with different mixtures of Cd and BDE-209 containing doses of Cd and BDE-209 stated above. Blood samples were taken at the end of experiment and red blood cells, white blood cells and platelets counts were determined. For interaction assessment multiple factorial regression analysis and fitted isobologram approach were used. In this study, we focused on multiple factorial regression analysis as a method for interaction assessment. We also investigated the interactions between Cd and BDE-209 by the derived model for the description of the obtained fitted isobologram curves. Current study indicated that co-exposure to Cd and BDE-209 can result in significant decrease in RBC count, increase in WBC count and decrease in PLT count, when compared with controls. Multiple factorial regression analysis used for the assessment of interactions type between Cd and BDE-209 indicated synergism for the effect on RBC count and no interactions i.e. additivity for the effects on WBC and PLT counts. On the other hand, isobologram based approach showed slight

  20. The challenges of analysing blood stains with hyperspectral imaging

    Science.gov (United States)

    Kuula, J.; Puupponen, H.-H.; Rinta, H.; Pölönen, I.

    2014-06-01

    Hyperspectral imaging is a potential noninvasive technology for detecting, separating and identifying various substances. In the forensic and military medicine and other CBRNE related use it could be a potential method for analyzing blood and for scanning other human based fluids. For example, it would be valuable to easily detect whether some traces of blood are from one or more persons or if there are some irrelevant substances or anomalies in the blood. This article represents an experiment of separating four persons' blood stains on a white cotton fabric with a SWIR hyperspectral camera and FT-NIR spectrometer. Each tested sample includes standardized 75 _l of 100 % blood. The results suggest that on the basis of the amount of erythrocytes in the blood, different people's blood might be separable by hyperspectral analysis. And, referring to the indication given by erythrocytes, there might be a possibility to find some other traces in the blood as well. However, these assumptions need to be verified with wider tests, as the number of samples in the study was small. According to the study there also seems to be several biological, chemical and physical factors which affect alone and together on the hyperspectral analyzing results of blood on fabric textures, and these factors need to be considered before making any further conclusions on the analysis of blood on various materials.

  1. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros

    OpenAIRE

    Jeffrine Japning Rovie-Ryan; Zainal Zahari Zainuddin; Wahap Marni; Abdul Hamid Ahmad; Laurentius N. Ambu; Junaidi Payne

    2013-01-01

    Objective: To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Methods: Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA® blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair fo...

  2. Blood hyperviscosity identification with reflective spectroscopy of tongue tip based on principal component analysis combining artificial neural network.

    Science.gov (United States)

    Liu, Ming; Zhao, Jing; Lu, XiaoZuo; Li, Gang; Wu, Taixia; Zhang, LiFu

    2018-05-10

    With spectral methods, noninvasive determination of blood hyperviscosity in vivo is very potential and meaningful in clinical diagnosis. In this study, 67 male subjects (41 health, and 26 hyperviscosity according to blood sample analysis results) participate. Reflectance spectra of subjects' tongue tips is measured, and a classification method bases on principal component analysis combined with artificial neural network model is built to identify hyperviscosity. Hold-out and Leave-one-out methods are used to avoid significant bias and lessen overfitting problem, which are widely accepted in the model validation. To measure the performance of the classification, sensitivity, specificity, accuracy and F-measure are calculated, respectively. The accuracies with 100 times Hold-out method and 67 times Leave-one-out method are 88.05% and 97.01%, respectively. Experimental results indicate that the built classification model has certain practical value and proves the feasibility of using spectroscopy to identify hyperviscosity by noninvasive determination.

  3. Advanced statistical analysis of Raman spectroscopic data for the identification of body fluid traces: semen and blood mixtures.

    Science.gov (United States)

    Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K

    2012-10-10

    Conventional confirmatory biochemical tests used in the forensic analysis of body fluid traces found at a crime scene are destructive and not universal. Recently, we reported on the application of near-infrared (NIR) Raman microspectroscopy for non-destructive confirmatory identification of pure blood, saliva, semen, vaginal fluid and sweat. Here we expand the method to include dry mixtures of semen and blood. A classification algorithm was developed for differentiating pure body fluids and their mixtures. The classification methodology is based on an effective combination of Support Vector Machine (SVM) regression (data selection) and SVM Discriminant Analysis of preprocessed experimental Raman spectra collected using an automatic mapping of the sample. This extensive cross-validation of the obtained results demonstrated that the detection limit of the minor contributor is as low as a few percent. The developed methodology can be further expanded to any binary mixture of complex solutions, including but not limited to mixtures of other body fluids. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. Impact of blood collection and processing on peripheral blood gene expression profiling in type 1 diabetes.

    Science.gov (United States)

    Yip, Linda; Fuhlbrigge, Rebecca; Atkinson, Mark A; Fathman, C Garrison

    2017-08-18

    The natural history of type 1 diabetes (T1D) is challenging to investigate, especially as pre-diabetic individuals are difficult to identify. Numerous T1D consortia have been established to collect whole blood for gene expression analysis from individuals with or at risk to develop T1D. However, with no universally accepted protocol for their collection, differences in sample processing may lead to variances in the results. Here, we examined whether the choice of blood collection tube and RNA extraction kit leads to differences in the expression of genes that are changed during the progression of T1D, and if these differences could be minimized by measuring gene expression directly from the lysate of whole blood. Microarray analysis showed that the expression of 901 genes is highly influenced by sample processing using the PAXgene versus the Tempus system. These included a significant number of lymphocyte-specific genes and genes whose expression has been reported to differ in the peripheral blood of at-risk and T1D patients compared to controls. We showed that artificial changes in gene expression occur when control and T1D samples were processed differently. The sample processing-dependent differences in gene expression were largely due to loss of transcripts during the RNA extraction step using the PAXgene system. The majority of differences were not observed when gene expression was measured in whole blood lysates prepared from blood collected in PAXgene and Tempus tubes. We showed that the gene expression profile of samples processed using the Tempus system is more accurate than that of samples processed using the PAXgene system. Variation in sample processing can result in misleading changes in gene expression. However, these differences can be minimized by measuring gene expression directly in whole blood lysates.

  5. Dried blood spots of pooled samples for RHD gene screening in blood donors of mixed ancestry.

    Science.gov (United States)

    Silva-Malta, M C F; Araujo, N C Fidélis; Vieira, O V Neves; Schmidt, L Cayres; Gonçalves, P de Cassia; Martins, M Lobato

    2015-10-01

    In this study, we present a strategy for RHD gene screening based on real-time polymerase chain reaction (PCR) using dried blood spots of pooled samples. Molecular analysis of blood donors may be used to detect RHD variants among the presumed D-negative individuals. RHD genotyping using pooled samples is a strategy to test a large number of samples at a more reasonable cost. RHD gene detection based on real-time PCR using dried blood spots of pooled samples was standardised and used to evaluate 1550 Brazilian blood donors phenotyped as RhD-negative. Positive results were re-evaluated by retesting single samples using real-time PCR and conventional multiplex PCR to amplify five RHD-specific exons. PCR-sequence-specific primers was used to amplify RHDψ allele. We devised a strategy for RHD gene screening using dried blood spots of five pooled samples. Among 1550 serologically D-negative blood donors, 58 (3.74%) had the RHD gene. The non-functional RHDψ allele was detected in 47 samples (3.02%). The present method is a promising strategy to detect the RHD gene among presumed RhD-negative blood donors, particularly for populations with African ancestry. © 2015 British Blood Transfusion Society.

  6. Application of dried blood spot cards to determine olive oil phenols (hydroxytyrosol metabolites) in human blood.

    Science.gov (United States)

    de Las Hazas, María Carmen López; Motilva, Maria José; Piñol, Carme; Macià, Alba

    2016-10-01

    In this study, a fast and simple blood sampling and sample pre-treatment method based on the use of the dried blood spot (DBS) cards and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) for the quantification of olive oil phenolic metabolites in human blood was developed and validated. After validation, the method was applied to determine hydroxytyrosol metabolites in human blood samples after the acute intake of an olive oil phenolic extract. Using the FTA DMPK-A DBS card under optimum conditions, with 20µL as the blood solution volume, 100µL of methanol/Milli-Q water (50/50, v/v) as the extraction solvent and 7 disks punched out from the card, the main hydroxytyrosol metabolites (hydroxytyrosol-3-O-sulphate and hydroxytyrosol acetate sulphate) were identified and quantified. The developed methodology allowed detecting and quantifying the generated metabolites at low μM levels. The proposed method is a significant improvement over existing methods to determine phenolic metabolites circulating in blood and plasma samples, thus making blood sampling possible with the volunteer pricking their own finger, and the subsequent storage of the blood in the DBS cards prior to chromatographic analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Dietary Interventions and Blood Pressure in Latin America - Systematic Review and Meta-Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mazzaro, Caroline Cantalejo; Klostermann, Flávia Caroline; Erbano, Bruna Olandoski [Faculdade Evangélica do Paraná, Curitiba, PR (Brazil); Schio, Nicolle Amboni; Guarita-Souza, Luiz César; Olandoski, Marcia; Faria-Neto, José Rocha, E-mail: jrochafaria@cardiol.br; Baena, Cristina Pellegrino [Pontifícia Universidade Católica do Paraná (PUC-PR), Curitiba, PR (Brazil)

    2014-04-15

    High blood pressure is the major risk factor for cardiovascular disease. Low blood pressure control rates in Latin American populations emphasize the need for gathering evidence on effective therapies. To evaluate the effects of dietary interventions on blood pressure in Latin American populations. Systematic review. Electronic databases (MEDLINE/PubMed, Embase, Cochrane Library, CINAHL, Web of Science, Scopus, SciELO, LILACS and VHL) were searched and manual search for studies published up to April 2013 was performed. Parallel studies about dietary interventions in Latin American adult populations assessing arterial blood pressure (mm Hg) before and after intervention were included. Of the 405 studies identified, 10 randomized controlled trials were included and divided into 3 subgroups according to the proposed dietary intervention. There was a non-significant reduction in systolic blood pressure in the subgroups of mineral replacement (-4.82; 95% CI: -11.36 to 1.73) and complex pattern diets (-3.17; 95% CI: -7.62 to 1.28). Regarding diastolic blood pressure, except for the hyperproteic diet subgroup, all subgroups showed a significant reduction in blood pressure: -4.66 mmHg (95% CI: -9.21 to -0.12) and -4.55 mmHg (95% CI: -7.04 to -2.06) for mineral replacement and complex pattern diets, respectively. Available evidence on the effects of dietary changes on blood pressure in Latin American populations indicates a homogeneous effect of those interventions, although not significant for systolic blood pressure. Samples were small and the quality of the studies was generally low. Larger studies are required to build robust evidence.

  8. Dietary Interventions and Blood Pressure in Latin America - Systematic Review and Meta-Analysis

    International Nuclear Information System (INIS)

    Mazzaro, Caroline Cantalejo; Klostermann, Flávia Caroline; Erbano, Bruna Olandoski; Schio, Nicolle Amboni; Guarita-Souza, Luiz César; Olandoski, Marcia; Faria-Neto, José Rocha; Baena, Cristina Pellegrino

    2014-01-01

    High blood pressure is the major risk factor for cardiovascular disease. Low blood pressure control rates in Latin American populations emphasize the need for gathering evidence on effective therapies. To evaluate the effects of dietary interventions on blood pressure in Latin American populations. Systematic review. Electronic databases (MEDLINE/PubMed, Embase, Cochrane Library, CINAHL, Web of Science, Scopus, SciELO, LILACS and VHL) were searched and manual search for studies published up to April 2013 was performed. Parallel studies about dietary interventions in Latin American adult populations assessing arterial blood pressure (mm Hg) before and after intervention were included. Of the 405 studies identified, 10 randomized controlled trials were included and divided into 3 subgroups according to the proposed dietary intervention. There was a non-significant reduction in systolic blood pressure in the subgroups of mineral replacement (-4.82; 95% CI: -11.36 to 1.73) and complex pattern diets (-3.17; 95% CI: -7.62 to 1.28). Regarding diastolic blood pressure, except for the hyperproteic diet subgroup, all subgroups showed a significant reduction in blood pressure: -4.66 mmHg (95% CI: -9.21 to -0.12) and -4.55 mmHg (95% CI: -7.04 to -2.06) for mineral replacement and complex pattern diets, respectively. Available evidence on the effects of dietary changes on blood pressure in Latin American populations indicates a homogeneous effect of those interventions, although not significant for systolic blood pressure. Samples were small and the quality of the studies was generally low. Larger studies are required to build robust evidence

  9. Dietary interventions and blood pressure in Latin America - systematic review and meta-analysis.

    Science.gov (United States)

    Mazzaro, Caroline Cantalejo; Klostermann, Flávia Caroline; Erbano, Bruna Olandoski; Schio, Nicolle Amboni; Guarita-Souza, Luiz César; Olandoski, Marcia; Faria-Neto, José Rocha; Baena, Cristina Pellegrino

    2014-04-01

    High blood pressure is the major risk factor for cardiovascular disease. Low blood pressure control rates in Latin American populations emphasize the need for gathering evidence on effective therapies. To evaluate the effects of dietary interventions on blood pressure in Latin American populations. Systematic review. Electronic databases (MEDLINE/PubMed, Embase, Cochrane Library, CINAHL, Web of Science, Scopus, SciELO, LILACS and VHL) were searched and manual search for studies published up to April 2013 was performed. Parallel studies about dietary interventions in Latin American adult populations assessing arterial blood pressure (mm Hg) before and after intervention were included. Of the 405 studies identified, 10 randomized controlled trials were included and divided into 3 subgroups according to the proposed dietary intervention. There was a non-significant reduction in systolic blood pressure in the subgroups of mineral replacement (-4.82; 95% CI: -11.36 to 1.73) and complex pattern diets (-3.17; 95% CI: -7.62 to 1.28). Regarding diastolic blood pressure, except for the hyperproteic diet subgroup, all subgroups showed a significant reduction in blood pressure: -4.66 mmHg (95% CI: -9.21 to -0.12) and -4.55 mmHg (95% CI: -7.04 to -2.06) for mineral replacement and complex pattern diets, respectively. Available evidence on the effects of dietary changes on blood pressure in Latin American populations indicates a homogeneous effect of those interventions, although not significant for systolic blood pressure. Samples were small and the quality of the studies was generally low. Larger studies are required to build robust evidence.

  10. The relationship between vacuum and hemolysis during catheter blood collection: a retrospective analysis of six large cohorts.

    Science.gov (United States)

    Mrazek, Cornelia; Simundic, Ana-Maria; Wiedemann, Helmut; Krahmer, Florian; Felder, Thomas Klaus; Kipman, Ulrike; Hoppe, Uta; Haschke-Becher, Elisabeth; Cadamuro, Janne

    2017-07-26

    Blood collection through intravenous (IV) catheters is a common practice at emergency departments (EDs). This technique is associated with higher in vitro hemolysis rates and may even be amplified by the use of vacuum collection tubes. Our aim was to investigate the association of five different vacuum tubes with hemolysis rates in comparison to an aspiration system under real-life conditions and to propose an equation to estimate the amount of hemolysis, depending on the vacuum collection tube type. We retrospectively evaluated hemolysis data of plasma samples from our ED, where blood is drawn through IV catheters. Over the past 5 years, we compared 19,001 hemolysis index values amongst each other and against the respective vacuum pressure (Pv) of the collection tubes, which were used within the six observational periods. The highest hemolysis rates were associated with full-draw evacuated tubes. Significantly reduced hemolysis was observed for two kinds of partial-draw tubes. The hemolysis rate of one partial-draw blood collection tube was comparable to those of the aspiration system. Regression analysis of Pv and mean free hemoglobin (fHb) values yielded the formula fHb (g/L)=0.0082*Pv2-0.1143*Pv+ 0.5314 with an R2 of 0.99. If IV catheters are used for blood collection, hemolysis rates directly correlate with the vacuum within the tubes and can be estimated by the proposed formula. By the use of partial-draw vacuum blood collection tubes, hemolysis rates in IV catheter collections can be reduced to levels comparable with collections performed by aspiration systems.

  11. Blood mercury can be a factor of elevated serum ferritin: analysis of Korea National Health and Nutrition Examination Survey (KNHANES 2008-2012).

    Science.gov (United States)

    Joo, Nam-Seok; Choi, Young-Hwa; Yeum, Kyung-Jin; Park, Soo-Jung; Choi, Beomhee; Kim, Young-Sang

    2015-03-01

    Serum ferritin as well as blood mercury are reported to be associated with chronic inflammation. However, the relation between serum ferritin and blood mercury has not yet been established. We utilized the Korea National Health and Nutrition Examination Survey (KNHANES, 2008-2012) 10,977 subjects (5433 males and 5544 females). To evaluate the association of serum ferritin and blood mercury cross-sectionally, complex sample analysis was conducted after adjustment for the relevant variables. Serum concentrations of ferritin and blood mercury were higher in males than in females (115.7 ± 1.7 vs. 40.9 ± 0.7 ng/mL and 5.0 ± 0.1 vs. 3.6 ± 0.1 μg/L, respectively). Serum ferritin and blood mercury concentrations had significant correlations in both genders after adjustment (r = 0.062, P mercury (P = 0.007) in males. The adjusted odds ratio of having the highest tertile of serum ferritin in the top tertile of blood mercury in males was 1.52 (95 % confidence interval (CI), 1.05-2.21). Thus, the current study indicates that blood mercury concentration can be a factor for the elevated serum ferritin concentration.

  12. Procedure for the in vitro determination of ammonia in blood

    International Nuclear Information System (INIS)

    Jung, K.; Faust, H.

    1985-01-01

    The invention has been aimed at a procedure for the in vitro determination of ammonia in blood based on microdiffusion and isotope dilution analysis. A definite quantity of blood serum has been mixed with a definite quantity of ammonium chloride labelled with the stable isotope 15 N. The mixture has been subjected to the microdiffusion (K 2 CO 3 additives and absorption of released ammonia in sulphuric acid). The ammonia bound in sulphuric acid has been devoted to a isotope analysis and the ammonia concentration of blood has been determined according to the isotope dilution analysis equation

  13. In-flight Blood Analysis Technology for Astronaut Health Monitoring

    Data.gov (United States)

    National Aeronautics and Space Administration — Blood staining and testing procedure optimization: A 5-part WBC differential (Lymphocyte, Monocyte, Neutrophil, Eosinophil, and Basophil) assay using a...

  14. [Patient blood management].

    Science.gov (United States)

    Folléa, G

    2016-11-01

    In a context of regular review of transfusion practice, the aim of this review is to present an update of the scientific basis of the so-called "patient blood management" (PBM), the state of its development in Europe, and possible ways to progress its development further in France. Analysis and synthesis of the data from scientific literature on the scientific basis of PBM (methods, indications, efficacy, risks, efficiency). PBM appears as an evidence-based, patient centred, multidisciplinary approach, aiming to optimise the care of patients who might need transfusion and, consequently, the use of blood products. PBM is based on three pillars: optimise the patient's own blood supplies, minimise blood loss, optimise patient's tolerance of anaemia. Available scientific evidence can be considered as sufficient to consider PBM guidelines and practices as an indispensable complement to the transfusion medicine guidelines and practices. Several countries have launched PBM programmes (alternatives to allogeneic transfusion and optimisation of the use of blood components). Although current French national transfusion guidelines contain some PBM measures, PBM programmes should be further developed in France, primarily for medical reasons. Possible ways, using the existing basis having proved to be effective, are proposed to further develop PBM in France, as a complement to transfusion medicine, with the participation of involved stakeholders, including experts from relevant medical specialties, both at local and national levels. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  15. Determination of lead in whole blood: Comparison of the LeadCare blood lead testing system with zeeman longitudinal electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pineau, A.; Viallefont, A.; Fauconneau, B.; Rafael, M.; Guillard, O.

    2002-01-01

    This study compares the efficiency of blood lead level analysis by graphite furnace atomic absorption spectrometry (GFAAS) and the portable LeadCare Blood lead testing system (LCS). Recoveries of two added lead concentrations of 22 and 42 μg/dL ranged from 102.4 to 105.5% for LCS and from 96.3 to 97.2% for GFAAS. Measurement of a certified sample (Certified Danish Whole Blood) at a blood lead concentration of 26.2 μg/dL gave within- and between-run coefficients of variation which were both approximately 8% by LCS and 2% by GFAAS. Comparison of the tested method (LCS) versus GFAAS from analysis of 76 samples of blood lead collected from workers in different industrial sectors showed imperfect overall correlation (r = 0.95). The LCS is quite suitable for screening purposes, but requires the use of non-frozen blood collected less than 24 h before. Conservative threshold values should be applied when using the LCS for initial screening in the field. (orig.)

  16. Data-driven analysis of blood glucose management effectiveness

    NARCIS (Netherlands)

    Nannings, B.; Abu-Hanna, A.; Bosman, R. J.

    2005-01-01

    The blood-glucose-level (BGL) of Intensive Care (IC) patients requires close monitoring and control. In this paper we describe a general data-driven analytical method for studying the effectiveness of BGL management. The method is based on developing and studying a clinical outcome reflecting the

  17. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  18. A Rational Framework for Production Decision Making in Blood Establishments

    Directory of Open Access Journals (Sweden)

    Ramoa Augusto

    2012-12-01

    Full Text Available SAD_BaSe is a blood bank data analysis software, created to assist in the management of blood donations and the blood production chain in blood establishments. In particular, the system keeps track of several collection and production indicators, enables the definition of collection and production strategies, and the measurement of quality indicators required by the Quality Management System regulating the general operation of blood establishments.

  19. At what age group blood pressure discontinue to increase? An assessment using change-point analysis

    Directory of Open Access Journals (Sweden)

    Khalib A. Latiff

    2010-05-01

    Full Text Available Aim To study at what age group blood pressure ceases to increase for women and men.Methods Applying change-point technique, we used our existing database - mega base-line cross-sectional Hulu Langat Health Study that was initiated in 2000 - to locate the most appropriate age limit in planning promotive, preventive and controlling strategies against systolic hypertension.Results Systolic hypertension was found to be constantly increasing for both gender right from the early age until the middle age group. However, women achieved the systolic peak 15 years earlier (at 41-45 years old than men (at 56-60 years old. Systolic blood pressure was steadily declined after the peak.Conclusions Hypertension intervention, we recommend age before 40 (women and 55 (men be the most appropriate period to apply various public health intervention, after that, the action must be exclusively curative. (Med J Indones 2010; 19:136-41Keywords: change-point analysis, public health intervention, systolic hypertension

  20. [Analysis on geographic distribution of high blood pressure prevalence in children and adolescents aged 7-18 years in China, 2014].

    Science.gov (United States)

    Dong, Y H; Zou, Z Y; Wang, Z H; Wang, S; Yang, Z P; Chen, Y J; Ma, J

    2017-07-10

    Objective: To understand and evaluate the characteristics of geographic distribution of high blood pressure prevalence in children and adolescents aged 7-18 years in China in 2014, and provide evidence for the prevention of hypertension in children and adolescents. Methods: The data of 2014 Chinese National Surveys on Students Constitution and Health conducting 31 provinces (except Hong Kong, Macao and Taiwan) were collected. A total of 216 299 children and adolescents who had complete blood pressure records were selected as study subjects. The low, middle and high prevalence areas were identified according to their high blood pressure detection rates in the children and adolescents,7 % , to analyze the geographic distribution of high blood pressure prevalence in the children and adolescents. The environmental data in the capitals of 31 provinces in 2014 were collected to analyze the correlation between environmental factors and blood pressure Z score in the children and adolescents. Results: The average detection rates of high blood pressure was 6.4 % in 31 provinces (1.5 % -14.2 % ). The high prevalence areas were mainly distributed in the eastern China, especially the Circum-Bohai sea area, low prevalence areas were mainly distributed in the central and western areas of China and some provinces in the east. Correlation analysis results showed that the annual average temperature, annual average air humidity and local altitude were negatively correlated with blood pressure Z score, including diastolic and systolic blood pressure, in both boys and girls. The annual average sunshine time, PM(2.5) and PM(10) concentrations, content of SO(2) were positively correlated with blood pressure Z score in both boys and girls. Conclusions: There was a significant difference in high blood pressure of children and adolescents among 31 provinces. More attention should be paid to the children and adolescents living high prevalence area. And it is necessary to understand

  1. The Amounts of As, Au, Br, Cu, Fe, Mo, Se and Zn in Normal and Uraemic Human whole Blood. A. Comparison by Means of Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Brune, D; Samsahl, K [AB Atomenergi, Nykoeping (Sweden); Wester, P O [Dept. of Medicine, Karolinska Inst., Serafimerlasarettet, Stockholm (Sweden)

    1964-01-15

    Quantitative determination of the elements As, Au, Br, Cu, Fe, Mo, Se and Zn have been performed in normal and uraemic human whole blood by means of H{sub 2}SO{sub 4} - H-O- digestion, distillation and ion exchange, combined with gamma-spectrometric analysis. The uraemic blood was found to contain about 10 times as much As and twice as much Mo as did the normal blood. As regards Fe, the uraemic blood contained slightly less than the normal blood. For the other elements there were no detectable difference.

  2. ASSOCIATION OF BIRTH ASPHYXIA WITH CORD BLOOD NUCLEATED RED BLOOD CELL

    Directory of Open Access Journals (Sweden)

    Poornima Shankar

    2018-02-01

    Full Text Available BACKGROUND Asphyxia can lead to severe hypoxic ischaemic organ damage in new-borns which may cause postnatal manifestation of hypoxicischaemic encephalopathy. Studies have found that the Apgar score failed to predict specific neurologic outcomes of the infants. Increased cord blood nucleated red blood cell in term neonates is an indicator of chronic intrauterine hypoxia. We set out to assess the role of nucleated RBC as a non-invasive, easy, cheap and at the same time early biochemical means of asphyxia diagnosis in our clinical setting. MATERIALS AND METHODS All inborn babies with Apgar scores <7 at 1 and 5 minutes of life were reviewed. Relevant information from mother case sheet were obtained. Cord blood samples was drawn and sent for blood gas analysis and number of NRBCs/100 white blood cells (WBC was determined using Leishman stain. RESULTS Our study proves the relevance of increase nucleated RBC in terms of early detection of birth asphyxia. Most common cause of birth asphyxia found was meconium aspiration. No co-relation was found with chorioamnionitis or maternal obstetrical history. CONCLUSION Many specific biomarkers are being investigated now a day for early detection of birth asphyxia. Umbilical cord pH is costly and may be underestimated in birth asphyxia. In our study, the elevated cord blood nRBC count was shown to be a good predictor of perinatal asphyxia. Since, it is cost-effective and does not require any special expertise or any high-tech facilities, it may be a useful, reliable, inexpensive and easily available marker to evaluate perinatal asphyxia. Hence, increase nucleated RBC has an important role in diagnosing and predicting the outcome of perinatal asphyxia.

  3. Whole blood donor deferral analysis at a center in Western India

    Directory of Open Access Journals (Sweden)

    Agnihotri Naveen

    2010-01-01

    Full Text Available Introduction: Deferrals lead to loss of precious whole blood donors (WBD and blood units available for transfusion purposes. Knowledge of rate and causes of donor deferral can guide the recruitment strategy for WBD. Aim: To find the incidence and causes of deferral in Indian WBD and apply relevant findings to modify recruitment strategy for blood donors. Materials and Methods: Data for WBD presenting for donation in a blood center and outdoor camps over one and half year were analyzed retrospectively. National guidelines were used for selection and deferral of WBD. Result: 736 (11.6% WBD were deferred out of 6357 presenting for donation during the study period. Most (69.8% of the donors were deferred on physical examination and hemoglobin (Hb testing. Most common reasons for deferral were low Hb (55.8%, abnormal blood pressure (11.1%, medication (6.9% and underweight donors (2.9%. Significantly more volunteers were deferred than relative donors (13.97% vs 5.80%; P<0.000. Females were found to have higher deferral rate than males (53.5% vs 6.9%; P=0.000 and higher odds ratio for deferral (15.4. Donors older than 40 years of age had significantly higher chance of being deferred (P<0.05. Discussion and Conclusion: It is important to determine the rate and causes of WBD deferral to guide the recruitment and retention efforts at local, regional, and national level.

  4. Association of betaine with blood pressure in dialysis patients.

    Science.gov (United States)

    Wang, Lulu; Zhao, Mingming; Liu, Wenjin; Li, Xiurong; Chu, Hong; Bai, Youwei; Sun, Zhuxing; Gao, Chaoqing; Zheng, Lemin; Yang, Junwei

    2018-02-01

    Mechanisms underlying elevated blood pressure in dialysis patients are complex as a variety of non-traditional factors are involved. We sought to explore the association of circulating betaine, a compound widely distributed in food, with blood pressure in dialysis patients. We used baseline data of an ongoing cohort study involving patients on hemodialysis. Plasma betaine was measured by high performance liquid chromatography in 327 subjects. Blood pressure level was determined by intradialytic ambulatory blood pressure monitoring. The mean age of the patients was 52.6 ± 11.9 years, and 58.4% were male. Average interdialytic ambulatory systolic and diastolic blood pressure were 138.4 ± 22.7 mm Hg and 84.4 ± 12.5 mm Hg, respectively. Mean plasma betaine level was 37.6 μmol/L. Multiple linear regression analysis revealed significant associations of betaine with both systolic blood pressure (β = -3.66, P = .003) and diastolic blood pressure (β = -2.00, P = .004). The associations persisted even after extensive adjustment for cardiovascular covariates. Subgroup analysis revealed that the association between betaine and blood pressure was mainly limited to female patients. Our data suggest that alteration of circulating betaine possibly contributes to blood pressure regulation in these patients. ©2018 Wiley Periodicals, Inc.

  5. Distribution of ABO Blood Groups and Coronary Artery Calcium.

    Science.gov (United States)

    Wang, Yao; Zhou, Bing-Yang; Zhu, Cheng-Gang; Guo, Yuan-Lin; Wu, Na-Qiong; Qing, Ping; Gao, Ying; Liu, Geng; Dong, Qian; Li, Jian-Jun

    2017-06-01

    ABO blood groups have been confirmed to be associated with cardiovascular diseases such as coronary artery disease. However, whether ABO blood group is correlated with coronary artery calcium (CAC) is still unknown. 301 patients with coronary artery calcium score (CACS) assessed by computed tomography were consecutively enrolled and divided into two groups: with calcium group (CACS>0, n=104) and without calcium group (CACS=0, n=197). Distribution of ABO blood groups was evaluated between the two groups. The percentage of A blood type was significantly higher (p=0.008) and O blood type was significantly lower (p=0.037) in the calcium group. Univariate regression analysis showed that age, total cholesterol, low density lipoprotein cholesterol, high-sensitivity C-reactive protein, A blood type were positively correlated with CAC, and O blood type was inversely associated with CAC. Multivariate regression analysis showed that A blood type was independently associated with CAC (odds ratio: 2.217, 95% confidence interval: 1.260-3.900, p=0.006) even after further adjustment for variables that were clearly different between the two groups. Our data has suggested for the first time that A blood type was an independent risk marker for CAC. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  6. Impact of the May 12, 2008, Earthquake on blood donations across five Chinese blood centers.

    Science.gov (United States)

    Liu, Jing; Huang, Yi; Wang, Jingxing; Bi, Xinhong; Li, Julin; Lu, Yunlai; Wen, Xiuqiong; Yao, Fuzhu; Dong, Xiangdong; He, Weilan; Huang, Mei; Ma, Hongli; Mei, Heili; King, Melissa; Wright, David J; Ness, Paul M; Shan, Hua

    2010-09-01

    On May 12, 2008, a severe earthquake struck China's Sichuan Province. The nationwide outpouring of charity resulted in a surge of subsequent blood donations. The quantity and quality of these donations were examined in comparison with routine donations. Whole blood and apheresis donations from five geographically different blood centers collected within 1 week postearthquake were compared with those collected during the rest of the year. Regional differences, demographic characteristics, first-time and repeat donor status, and infectious disease screening markers associated with these donations were compared by earthquake status using chi-square statistics. Poisson regression analysis examined the number of daily donations by earthquake status after adjusting for center, day of week, and seasonal variations. The number of daily donations across five blood centers increased from 685 on a typical day to 1151 in the postearthquake week. The surge was observed in both sexes and across different education levels, age, and ethnicity groups and three blood centers and was significant after adjusting for confounding covariates. The influx of first-time donors (89.5%) was higher than that of repeat donors (34%). There was a significant change in the overall screening reactive marker rates excluding alanine aminotransferase (2.06% vs. 1.72%% vs. 4.96%). However, when the individual screening test was analyzed separately, no significant differences were found. Timely donations in response to a disaster are crucial to ensure emergency blood transfusion. The dramatically increased postearthquake donations suggest that Chinese blood centers are capable of handling emergency blood needs. Measures to maintain blood safety should be taken in times of emergency. © 2010 American Association of Blood Banks.

  7. Analysis of Proteolytic and Fibrinolytic Activity of the Blood Plasma in Patients with Bronchial Asthma Combined with Obesity

    Directory of Open Access Journals (Sweden)

    Fediv A.I. Fediv A.I.

    2016-09-01

    Full Text Available Aim of the study — to conduct the analysis of the performance of proteolytic and fibrinolytic activity of the blood plasma in patients with bronchial asthma (BA combined with obesity. Materials and methods. The study included 40 patients divided into groups. The basic group consisted of 20 patients with BA associated with obesity (ІI group, two comparison groups — of 10 patients with BA and normal body weight (I group and 10 patients with obesity and without pathology of the bronchopulmonary system (ІІІ group. Control group included 10 apparently healthy persons. In patients with BA, there were investigated the indexes of proteolytic and fibrinolytic activity of the blood plasma. Results. Analysis of the obtained data in patients with BA showed an increase of activity of plasma coagulation factors: total fibrinolytic activity increased in comparison to the control group, and in patients with BA it was 1.46 ± 0.13 Е440/ml/h, while in apparently healthy persons — 1.23 ± 0.16 Е440/ml/h (р < 0.05. In addition, an increase was marked and in the group of patients with the isolated obesity (by 38.5 % as compared to the group of apparently healthy persons, that can be explained by the growth of activity of inflammatory process due to the immune changes related to biological activity of fatty tissue as an additional source of proinflammatory cytokines. Conclusions. In combination of bronchial asthma and obesity, there is an activation of fibrinolytic and proteolytic systems of the blood that leads to microcirculatory and hemostatic disorders, enhancement of inflammatory process. In obesity as the state of systemic inflammatory response, the activation of fibrinolytic and proteolytic blood systems is more significant, than in bronchial asthma.

  8. Predictive Value of Intraoperative Thromboelastometry for the Risk of Perioperative Excessive Blood Loss in Infants and Children Undergoing Congenital Cardiac Surgery: A Retrospective Analysis.

    Science.gov (United States)

    Kim, Eunhee; Shim, Haeng Seon; Kim, Won Ho; Lee, Sue-Young; Park, Sun-Kyung; Yang, Ji-Hyuk; Jun, Tae-Gook; Kim, Chung Su

    2016-10-01

    Laboratory hemostatic variables and parameters of rotational thromboelastometry (ROTEM) were evaluated for their ability to predict perioperative excessive blood loss (PEBL) after congenital cardiac surgery. Retrospective and observational. Single, large university hospital. The study comprised 119 children younger than 10 years old undergoing congenital cardiac surgery with cardiopulmonary bypass (CPB). Intraoperative excessive blood loss was defined as estimated blood loss≥50% of estimated blood volume (EBV). Postoperative excessive blood loss was defined as measured postoperative chest tube and Jackson-Pratt drainage≥30% of EBV over 12 hours or≥50% of EBV over 24 hours in the intensive care unit. PEBL was defined as either intraoperative or postoperative excessive blood loss. External temogram (EXTEM) and fibrinogen temogram (FIBTEM) were analyzed before and after CPB with ROTEM and laboratory hemostatic variables. Multivariate logistic regression was performed. Incidence of PEBL was 19.3% (n = 23). Independent risk factors for PEBL were CPB time>120 minutes, post-CPB FIBTEM alpha-angle, clot firmness after 10 minutes20%. Laboratory hemostatic variables were not significant in multivariate analysis. The risk prediction model was developed from the results of multivariate analysis. The area under the receiver operating characteristic curve was 0.94 (95% confidence interval: 0.90-0.99). Post-CPB ROTEM may be useful for predicting both intraoperative and postoperative excessive blood loss in congenital cardiac surgery. This study provided an accurate prediction model for PEBL and supported intraoperative transfusion guidance using post-CPB FIBTEM-A10 and EXTEM-A10. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Direct analysis of formate in human plasma, serum and whole blood by in-line coupling of microdialysis to capillary electrophoresis for rapid diagnosis of methanol poisoning

    OpenAIRE

    Kubáň, P. (Pavel); Boček, P. (Petr)

    2013-01-01

    A microdialytic device was in-line coupled to capillary electrophoresis for direct injection of blood samples. Its performance was demonstrated on rapid analysis of formic acid in various blood samples including serum samples of a patient diagnosed with acute methanol poisoning.

  10. TRANSFUSION OF BLOOD AND BLOOD COMPONENTS IN POLYTRAUMATISED PATIENTS AT CELJE HOSPITAL (1998–2001

    Directory of Open Access Journals (Sweden)

    Slavomir Milovanović

    2003-12-01

    Full Text Available Background. The replacement of fluids after severe injuries is always a complex issue, either in medical doctrine or in clinical practice. Regardless of the fact, daily work with patients requires the clearest possible guidelines and their regular monitoring.Methods. We made a chart showing the number of patients and the quantity of blood or blood components used in the Celje General Hospital in the past four years.Results. The analyses have shown that indications for the use of blood or blood components have narrowed. At the same time, it is quite evident that it is difficult and also risky to decide on a transfusion only on the given laboratory values. Only a careful analysis of the therapy has shown that the decision on a transfusion is based on both, the clinical picture and its development, the evaluation of visible and invisible loss of blood, and on regular and extensive laboratory monitoring.Conclusions. Despite improved surgical techniques and introduction of new transfusion strategies loss of blood and need for transfusion during and after polytrauma surgeries is still rather high. In the analysed four year period, the maintained level of haemoglobin in patients that had a major surgery has slightly declined. It is therefore essential to cooperate with the respective hospital transfusion committee and prepare as well as follow up some clear guidelines for the rationalisation, not only restriction of transfusion of blood and blood components.

  11. Economic burden of malignant blood disorders across Europe: a population-based cost analysis.

    Science.gov (United States)

    Burns, Richeal; Leal, Jose; Sullivan, Richard; Luengo-Fernandez, Ramon

    2016-08-01

    Malignant blood disorders are a leading contributor to cancer incidence and mortality across Europe. Despite their burden, no study has assessed the economic effect of blood cancers in Europe. We aimed to assess the economic burden of malignant blood disorders across the 28 countries in the European Union (EU), Iceland, Norway, and Switzerland. Malignant blood disorder-related costs were estimated for 28 EU countries, Iceland, Norway, and Switzerland for 2012. Country-specific costs were estimated with aggregate data on morbidity, mortality, and health-care resource use obtained from international and national sources. Health-care costs were estimated from expenditure on primary, outpatient, emergency, inpatient care, and drugs. Costs of informal care and productivity losses due to morbidity and early death were also included. For countries in the EU, malignant blood disorders were compared with the economic burden of overall cancer. Malignant blood disorders cost the 31 European countries €12 billion in 2012. Health-care cost €7·3 billion (62% of total costs), productivity losses cost €3·6 billion (30%), and informal care cost €1 billion (8%). For the EU countries, malignant blood disorders cost €6·8 billion (12%) of the total health-care expenditure on cancer (€57 billion), with this proportion being second only to breast cancer. In terms of total cancer costs in the EU (€143 billion), malignant blood disorders cost €12 billion (8%). Malignant blood disorders represent a leading cause of death, health-care service use, and costs, not only to European health-care systems, but to society overall. Our results add to essential public health knowledge needed for effective national cancer-control planning and priorities for public research funding. European Hematology Association. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Analysis of human serum and whole blood for mineral content by ICP-MS and ICP-OES: development of a mineralomics method.

    Science.gov (United States)

    Harrington, James M; Young, Daniel J; Essader, Amal S; Sumner, Susan J; Levine, Keith E

    2014-07-01

    Minerals are inorganic compounds that are essential to the support of a variety of biological functions. Understanding the range and variability of the content of these minerals in biological samples can provide insight into the relationships between mineral content and the health of individuals. In particular, abnormal mineral content may serve as an indicator of illness. The development of robust, reliable analytical methods for the determination of the mineral content of biological samples is essential to developing biological models for understanding the relationship between minerals and illnesses. This paper describes a method for the analysis of the mineral content of small volumes of serum and whole blood samples from healthy individuals. Interday and intraday precision for the mineral content of the blood (250 μL) and serum (250 μL) samples was measured for eight essential minerals--sodium (Na), calcium (Ca), magnesium (Mg), potassium (K), iron (Fe), zinc (Zn), copper (Cu), and selenium (Se)--by plasma spectrometric methods and ranged from 0.635 to 10.1% relative standard deviation (RSD) for serum and 0.348-5.98% for whole blood. A comparison of the determined ranges for ten serum samples and six whole blood samples provided good agreement with literature reference ranges. The results demonstrate that the digestion and analysis methods can be used to reliably measure the content of these minerals and potentially of other minerals.

  13. Quantitative interpretations of Visible-NIR reflectance spectra of blood.

    Science.gov (United States)

    Serebrennikova, Yulia M; Smith, Jennifer M; Huffman, Debra E; Leparc, German F; García-Rubio, Luis H

    2008-10-27

    This paper illustrates the implementation of a new theoretical model for rapid quantitative analysis of the Vis-NIR diffuse reflectance spectra of blood cultures. This new model is based on the photon diffusion theory and Mie scattering theory that have been formulated to account for multiple scattering populations and absorptive components. This study stresses the significance of the thorough solution of the scattering and absorption problem in order to accurately resolve for optically relevant parameters of blood culture components. With advantages of being calibration-free and computationally fast, the new model has two basic requirements. First, wavelength-dependent refractive indices of the basic chemical constituents of blood culture components are needed. Second, multi-wavelength measurements or at least the measurements of characteristic wavelengths equal to the degrees of freedom, i.e. number of optically relevant parameters, of blood culture system are required. The blood culture analysis model was tested with a large number of diffuse reflectance spectra of blood culture samples characterized by an extensive range of the relevant parameters.

  14. Effect of cocoa products on blood pressure: systematic review and meta-analysis.

    Science.gov (United States)

    Desch, Steffen; Schmidt, Johanna; Kobler, Daniela; Sonnabend, Melanie; Eitel, Ingo; Sareban, Mahdi; Rahimi, Kazem; Schuler, Gerhard; Thiele, Holger

    2010-01-01

    Cocoa products such as dark chocolate and cocoa beverages may have blood pressure (BP)-lowering properties due to their high content of plant-derived flavanols. We performed a meta-analysis of randomized controlled trials assessing the antihypertensive effects of flavanol-rich cocoa products. The primary outcome measure was the change in systolic and diastolic BP between intervention and control groups. In total, 10 randomized controlled trials comprising 297 individuals were included in the analysis. The populations studied were either healthy normotensive adults or patients with prehypertension/stage 1 hypertension. Treatment duration ranged from 2 to 18 weeks. The mean BP change in the active treatment arms across all trials was -4.5 mm Hg (95% confidence interval (CI), -5.9 to -3.2, P cocoa products in a larger set of trials than previously reported. However, significant statistical heterogeneity across studies could be found, and questions such as the most appropriate dose and the long-term side effect profile warrant further investigation before cocoa products can be recommended as a treatment option in hypertension.

  15. Quantification of facial contamination with blood during orthopaedic procedures.

    LENUS (Irish Health Repository)

    Collins, D

    2012-02-03

    Operative surgery exposes the surgeon to possible blood-borne infections. Risks include pen-etrating injuries and conjunctival contact with infected blood. Visor masks worn during orthopaedic trauma procedures were assessed for blood contamination using computer analysis. This was found to be present on 86% of masks, of which only 15% was recognized by the surgeon intraoperatively. Of the blood splashes 80% were less than 0.6mm in diameter. We conclude that power instrumentation produces a blood particulate mist causing considerable microscopic, facial contamination which is a significant risk to the surgeon.

  16. Limiting excessive postoperative blood transfusion after cardiac procedures. A review.

    OpenAIRE

    Ferraris, V A; Ferraris, S P

    1995-01-01

    Analysis of blood product use after cardiac operations reveals that a few patients ( 80%). The risk factors that predispose a minority of patients to excessive blood use include patient-related factors, transfusion practices, drug-related causes, and procedure-related factors. Multivariate studies suggest that patient age and red blood cell volume are independent patient-related variables that predict excessive blood product transfusion aft...

  17. Analysis of the complex formation of heparin with protamine by light scattering and analytical ultracentrifugation: implications for blood coagulation management.

    Science.gov (United States)

    Maurer, Jürgen; Haselbach, Stephanie; Klein, Oliver; Baykut, Doan; Vogel, Vitali; Mäntele, Werner

    2011-02-02

    Heparin, a linear glycosaminoglycan, is used in different forms in anticoagulation treatment. Protamine, a highly positive charged peptide containing about 32 amino acids, acts as an antagonist for heparin to restore normal blood coagulation. The complex formation of protamine with heparin was analyzed by a combination of analytical ultracentrifugation and light scattering. Titration of heparin with protamine in blood plasma preparations results in a drastic increase of turbidity, indicating the formation of nanoscale particles. A similar increase of turbidity was observed in physiological saline solution with or without human serum albumin (HSA). Particle size analysis by analytical ultracentrifugation revealed a particle radius of approximately 30 nm for unfractionated heparin and of approximately 60 nm for low molecular weight heparin upon complexation with excess protamine, in agreement with atomic force microscopy data. In the absence of HSA, larger and more heterogeneous particles were observed. The particles obtained were found to be stable for hours. The particle formation kinetics was analyzed by light scattering at different scattering angles and was found to be complete within several minutes. The time course of particle formation suggests a condensation reaction, with sigmoidal traces for low heparin concentrations and quasi-first-order reaction for high heparin concentrations. Under all conditions, the final scattering intensity reached after several minutes was found to be proportional to the amount of heparin in the blood plasma or buffer solution, provided that excess protamine was available and no multiple scattering occurred. On the basis of a direct relation between particle concentration and the heparin concentration present before protaminization, a light scattering assay was developed which permits the quantitative analysis of the heparin concentration in blood plasma and which could complement or even replace the activated clotting time test

  18. Resistance training alone reduces systolic and diastolic blood pressure in prehypertensive and hypertensive individuals: meta-analysis.

    Science.gov (United States)

    de Sousa, Evitom Corrêa; Abrahin, Odilon; Ferreira, Ana Lorena Lima; Rodrigues, Rejane Pequeno; Alves, Erik Artur Cortinhas; Vieira, Rodolfo Paula

    2017-11-01

    The purpose of this study was to evaluate the effects of resistance training alone on the systolic and diastolic blood pressure in prehypertensive and hypertensive individuals. Our meta-analysis, followed the guidelines of PRISMA. The search for articles was realized by November 2016 using the following electronic databases: BIREME, PubMed, Cochrane Library, LILACS and SciELO and a search strategy that included the combination of titles of medical affairs and terms of free text to the key concepts: 'hypertension' 'hypertensive', 'prehypertensive', 'resistance training', 'strength training', and 'weight-lifting'. These terms were combined with a search strategy to identify randomized controlled trials (RCTs) and identified a total of 1608 articles: 644 articles BIREME, 53 SciELO, 722 PubMed, 122 Cochrane Library and 67 LILACS. Of these, five RCTs met the inclusion criteria and provided data on 201 individuals. The results showed significant reductions for systolic blood pressure (-8.2 mm Hg CI -10.9 to -5.5;I 2 : 22.5% P valor for heterogeneity=0.271 and effect size=-0.97) and diastolic blood pressure (-4.1 mm Hg CI -6.3 to -1.9; I 2 : 46.5% P valor for heterogeneity=0.113 and effect size=-0.60) when compared to group control. In conclusion, resistance training alone reduces systolic and diastolic blood pressure in prehypertensive and hypertensive subjects. The RCTs studies that investigated the effects of resistance training alone in prehypertensive and hypertensive patients support the recommendation of resistance training as a tool for management of systemic hypertension.

  19. Microfluidic Cytometer for Complete Blood Count Analysis, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — RMD proposes to develop a MEMS based complete blood count (CBC) instrument that can be used aboard a spacecraft. We will produce a microfluidic scale combination...

  20. Analysis of tacrolimus and creatinine from a single dried blood spot using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Koop, Dennis R; Bleyle, Lisa A; Munar, Myrna; Cherala, Ganesh; Al-Uzri, Amira

    2013-05-01

    Long term therapeutic drug monitoring and assessment of renal function are required in renal transplant recipients on immunosuppressant therapy such as tacrolimus. Dry blood spots (DBS) have been used successfully in the clinic for many years and offers a convenient, simple and non-invasive method for repeated blood tests. We developed and performed a preliminary validation of a method for the analysis of tacrolimus and creatinine from a single DBS using liquid chromatography-tandem mass spectrometric (LC-MS/MS). Tacrolimus and creatinine were extracted from a 6mm punch with a mixture of methanol/acetonitrile containing ascomycin and deuterated creatinine as internal standards. A 10 μl aliquot of the extract was analyzed directly after dilution for creatinine with normal phase high performance liquid chromatography and multiple reaction monitoring. The remainder of the extract was processed and analyzed for tacrolimus. The lower limit of quantification for tacrolimus was 1 ng/ml with accuracy of 0.34% bias and precision (CV) of 11.1%. The precision ranged from 1.33% to 7.68% and accuracy from -4.44% to 11.6% bias for the intra- and inter-day analysis. The lower limit of quantification of creatinine was 0.01 mg/dL with precision of 7.94%. Accuracy was based on recovery of additional creatinine spiked into whole blood samples and ranged from -2.45% bias at 5 mg/dL to 3.75% bias at 0.5 mg/dL. Intra- and inter-day precision was from 3.48 to 4.11%. The assay was further validated with DBS prepared from pediatric renal transplant recipients. There was excellent correlation between the levels of tacrolimus and creatinine obtained from the clinical laboratory and the DBS method developed. After additional validation, this assay may have a significant impact on compliance with medication intake as well as potentially lowering the cost associated with intravenous blood draws in clinical laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Restrictive versus liberal blood transfusion in patients with coronary artery disease: a meta-analysis.

    Science.gov (United States)

    Wang, Yushu; Shi, Xiuli; Wen, Meiqin; Chen, Yucheng; Zhang, Qing

    2017-04-01

    To compare clinical outcomes between restrictive versus liberal blood transfusion strategies in patients with coronary artery disease (CAD). A literature search from January 1966 to May 2016 was performed in PubMed, EMBASE and Cochrane Library to find trials evaluating a restrictive hemoglobin transfusion trigger of ≤8 g/dL, compared with a more liberal trigger. Two study authors independently extracted data from the trials. The primary outcome was mortality and the secondary outcome was subsequent myocardial infarction. Relative risks (RRs) with their 95% confidence intervals (CIs) were assessed. Six trials involving 133,058 participants were included in this study. Pooled results revealed no difference in mortality between the liberal transfusion and restrictive transfusions (RR = 1.17, 95% CI = 0.91-1.52, P = .22). Subgroup analysis revealed that a restrictive transfusion strategy was associated with a higher risk of in-hospital mortality (RR = 1.38, 95% CI = 1.15-1.67, P transfusion strategy and restrictive transfusion strategy in risk for subsequent myocardial infarction (RR = 1.09, 95% CI = 0.57-2.06, P = .80). Limitations include (1) limited number of trials, especially those evaluating myocardial infarction, (2) observed heterogeneity, (3) confounding by indication and other inherent bias may exist. The findings suggest that restrictive blood transfusion was associated with higher in-hospital and 30 day mortality than liberal blood transfusion in CAD patients. The conclusions are mainly based on retrospective studies and should not be considered as recommendation before they are supported by randomized controlled trials.

  2. Blood transfusion in preterm infants improves intestinal tissue oxygenation without alteration in blood flow.

    Science.gov (United States)

    Banerjee, J; Leung, T S; Aladangady, N

    2016-11-01

    The objective of the study was to investigate the splanchnic blood flow velocity and oximetry response to blood transfusion in preterm infants according to postnatal age. Preterm infants receiving blood transfusion were recruited to three groups: 1-7 (group 1; n = 20), 8-28 (group 2; n = 21) and ≥29 days of life (group 3; n = 18). Superior mesenteric artery (SMA) peak systolic (PSV) and diastolic velocities were measured 30-60 min pre- and post-transfusion using Doppler ultrasound scan. Splanchnic tissue haemoglobin index (sTHI), tissue oxygenation index (sTOI) and fractional tissue oxygen extraction (sFTOE) were measured from 15-20 min before to post-transfusion using near-infrared spectroscopy. The mean pretransfusion Hb in group 1, 2 and 3 was 11, 10 and 9 g/dl, respectively. The mean (SD) pretransfusion SMA PSV in group 1, 2 and 3 was 0·63 (0·32), 0·81 (0·33) and 0·97 (0·40) m/s, respectively, and this did not change significantly following transfusion. The mean (SD) pretransfusion sTOI in group 1, 2 and 3 was 36·7 (19·3), 44·6 (10·4) and 41·3 (10·4)%, respectively. The sTHI and sTOI increased (P transfusion in all groups. On multivariate analysis, changes in SMA PSV and sTOI following blood transfusion were not associated with PDA, feeding, pretransfusion Hb and mean blood pressure. Pretransfusion baseline splanchnic tissue oximetry and blood flow velocity varied with postnatal age. Blood transfusion improved intestinal tissue oxygenation without altering mesenteric blood flow velocity irrespective of postnatal ages. © 2016 International Society of Blood Transfusion.

  3. Quantitative Analysis of Regional Cerebral Blood Flow using 99mTc-HMPAO SPECT in Parkinson's Disease

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Bae, Sang Kyun; Chung, June Key; Koh, Chang Soon; Roh, Jae Kyu; Myung, Ho Jin; Lee, Myung Hae

    1992-01-01

    Regional cerebral blood flow were measured in 10 patients with Parkinson's disease and 12 normal persons using 99m Tc-HMPAO SPECT. Reconstructed images were interpreted qualitatively and were compared with those findings of CT. For the quantitative analysis, six pairs of region of interest matched with the perfusion territories of large cerebral arteries and cerebellar hemisphere were determined. From the count values, indices showing the degree of asymmetry between right and left cerebral or cerebellar hemisphere, cerebral asymmetry index (ASI) and percent index of cerebellar asymmetry (PIA), and an index showing change of each region, region to cerebellum ratio (RCR) were obtained. ASI of normal persons and patients were 0.082 ± 0.033 and 0.108 ± 0.062, respectively and PIA were -0.4 ± 0.7% and -0.7 ± 1.0%, respectively, which showed no statistically significant difference between normal persons and patients. Among 10 RCR's, those of both regions of basal ganglia and both regions of anterior cerebral artery were significantly reduced. We concluded that the most significant reduction of regional cerebral blood flow in patients with Parkinson's disease was observed in the regions of basal ganglia and in the regions of anterior cerebral artery, and the degree of change in hemispheric blood flow was similar in both hemisphere.

  4. Time-Series Analysis of Continuously Monitored Blood Glucose: The Impacts of Geographic and Daily Lifestyle Factors

    Directory of Open Access Journals (Sweden)

    Sean T. Doherty

    2015-01-01

    Full Text Available Type 2 diabetes is known to be associated with environmental, behavioral, and lifestyle factors. However, the actual impacts of these factors on blood glucose (BG variation throughout the day have remained relatively unexplored. Continuous blood glucose monitors combined with human activity tracking technologies afford new opportunities for exploration in a naturalistic setting. Data from a study of 40 patients with diabetes is utilized in this paper, including continuously monitored BG, food/medicine intake, and patient activity/location tracked using global positioning systems over a 4-day period. Standard linear regression and more disaggregated time-series analysis using autoregressive integrated moving average (ARIMA are used to explore patient BG variation throughout the day and over space. The ARIMA models revealed a wide variety of BG correlating factors related to specific activity types, locations (especially those far from home, and travel modes, although the impacts were highly personal. Traditional variables related to food intake and medications were less often significant. Overall, the time-series analysis revealed considerable patient-by-patient variation in the effects of geographic and daily lifestyle factors. We would suggest that maps of BG spatial variation or an interactive messaging system could provide new tools to engage patients and highlight potential risk factors.

  5. Certain Red Blood Cell Indices of Maternal and Umbilical Cord ...

    African Journals Online (AJOL)

    Uche

    Background: Umbilical cord blood analysis may give a clue to the state of health of both pregnant mothers and their neonates. However ... Keywords: Umbilical cord blood; maternal blood; haemoglobin concentration; packed cell volume; red cell indices. Received on .... The packed cell volume was measured using the.

  6. Analysis of blood clearance and labeled metabolites for the estrogen receptor tracer [F-18]-16α-fluorestradiol (FES)

    International Nuclear Information System (INIS)

    Mankoff, David A.; Tewson, Timothy J.; Eary, Janet F.

    1997-01-01

    [F-18] 16α-Fluoroestradiol (FES) has been shown to be a tracer of estrogen receptor content in breast tumors; however, quantitative analysis of FES images is complicated by the rapid metabolism of the tracer in vivo. To optimize FES PET imaging studies and to provide an input function for the quantitative analysis of the tracer FES uptake in breast tumors, we studied the clearance and metabolism of FES in 15 breast cancer patients. FES clearance, protein binding, and metabolite production and limited assays to determine the identity of labeled metabolites were performed. These studies show that FES was rapidly cleared from the blood and metabolized; at 20 min only 20% of the circulating radioactivity was unmetabolized FES, and much of this was protein bound. The detectable metabolites in either blood or urine are conjugation products, largely the glucuronide and the sulfate of FES, and these are excreted through the kidneys at a rate comparable to their introduction into the circulation. After 20 min postinjection the blood levels of radioactivity remain fairly constant. Our results, the first report on human metabolites, are in close agreement with previous animal studies of FES metabolism. These studies show that because FES clearance is rapid and metabolite background is nearly constant, imaging starting at 20 to 30 min after injection may provide good visualization of estrogen-containing tissues. Labeled metabolites need to be accounted for in quantifying FES uptake

  7. Interaction between peri-operative blood transfusion, tidal volume, airway pressure and postoperative ARDS: an individual patient data meta-analysis.

    Science.gov (United States)

    Serpa Neto, Ary; Juffermans, Nicole P; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Biehl, Michelle; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; Jaber, Samir; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Memtsoudis, Stavros G; Miranda, Dinis Reis; Moine, Pierre; Paparella, Domenico; Ranieri, Marco; Scavonetto, Federica; Schilling, Thomas; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2018-01-01

    Transfusion of blood products and mechanical ventilation with injurious settings are considered risk factors for postoperative lung injury in surgical Patients. A systematic review and individual patient data meta-analysis was done to determine the independent effects of peri-operative transfusion of blood products, intra-operative tidal volume and airway pressure in adult patients undergoing mechanical ventilation for general surgery, as well as their interactions on the occurrence of postoperative acute respiratory distress syndrome (ARDS). Observational studies and randomized trials were identified by a systematic search of MEDLINE, CINAHL, Web of Science, and CENTRAL and screened for inclusion into a meta-analysis. Individual patient data were obtained from the corresponding authors. Patients were stratified according to whether they received transfusion in the peri-operative period [red blood cell concentrates (RBC) and/or fresh frozen plasma (FFP)], tidal volume size [≤7 mL/kg predicted body weight (PBW), 7-10 and >10 mL/kg PBW] and airway pressure level used during surgery (≤15, 15-20 and >20 cmH 2 O). The primary outcome was development of postoperative ARDS. Seventeen investigations were included (3,659 patients). Postoperative ARDS occurred in 40 (7.2%) patients who received at least one blood product compared to 40 patients (2.5%) who did not [adjusted hazard ratio (HR), 2.32; 95% confidence interval (CI), 1.25-4.33; P=0.008]. Incidence of postoperative ARDS was highest in patients ventilated with tidal volumes of >10 mL/kg PBW and having airway pressures of >20 cmH 2 O receiving both RBC and FFP, and lowest in patients ventilated with tidal volume of ≤7 mL/kg PBW and having airway pressures of ≤15 cmH 2 O with no transfusion. There was a significant interaction between transfusion and airway pressure level (P=0.002) on the risk of postoperative ARDS. Peri-operative transfusion of blood products is associated with an increased risk of

  8. [Traces of blood. The significance of blood in criminology at the turn of the 19th century].

    Science.gov (United States)

    Bachhiesl, Christian

    2010-03-01

    In late 19th and early 20th century, criminology became institutionalized as an independent branch of science. Methodologically it focused on the 'exact' methods of the natural sciences, but also it tried to integrate the methods of the humanities. This mix of methods becomes visible in the treatment of blood, which on the one hand was an object of then brand new methods of scientific analysis (identification of human blood by the biological or precipitin method), and on the other hand was analyzed as a product of the magic and superstitious mentalities of criminals. The methodical tension resulting from this epistemological crossbreeding did not disturb the criminologists, for whom the reconciliation of opposite ways of thinking and researching seemed to be possible. In this encyclopaedic analysis of blood early criminology tried to combine the anthropological exploration of vampirism with the chemical and microscopic detection of antibodies and haemoglobin, thus mirroring the positivistic optimism that was then prevalent.

  9. Hepatobiliary system functional analysis by blood flow and clearance delay model

    International Nuclear Information System (INIS)

    Aboltins, A.; Reinholds, E.

    2002-01-01

    A mathematical model for describing liver uptake-excretion is developed and approved. Model is based on different timing delays in hepatobiliary and blood flow system elements. Series of scintigraphic images with 99m Tc-mebrofenins or 99m Tc-HIDA taken with standard nuclear medicine gamma camera are used as the real data for calculations. The time-activity curves are obtained from many regions of human body - heart, liver, gallbladder, spleen, aorta, vein, etc. Both first pass and dynamic acquisition data are used. Results are calculated using real system parameters and compared to real scintigraphy data. Mathematical simulations are made to show difference of hepatobiliary system function at three main points: normal function, good blood flow with bad hepatic function and bad blood flow with good hepatic function. (authors)

  10. Worldwide trends in blood pressure from 1975 to 2015

    DEFF Research Database (Denmark)

    Linneberg, Allan René; Sørensen, Thorkild I.A.

    2017-01-01

    BACKGROUND: Raised blood pressure is an important risk factor for cardiovascular diseases and chronic kidney disease. We estimated worldwide trends in mean systolic and mean diastolic blood pressure, and the prevalence of, and number of people with, raised blood pressure, defined as systolic blood...... pressure of 140 mm Hg or higher or diastolic blood pressure of 90 mm Hg or higher. METHODS: For this analysis, we pooled national, subnational, or community population-based studies that had measured blood pressure in adults aged 18 years and older. We used a Bayesian hierarchical model to estimate trends...... from 1975 to 2015 in mean systolic and mean diastolic blood pressure, and the prevalence of raised blood pressure for 200 countries. We calculated the contributions of changes in prevalence versus population growth and ageing to the increase in the number of adults with raised blood pressure. FINDINGS...

  11. Analysis of Hypodermic Needles and Syringes for the Presence of Blood and Polydimethylsiloxane (Silicone) Utilizing Microchemical Tests and Infrared Spectroscopy.

    Science.gov (United States)

    Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E

    2015-07-01

    Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  12. Beat-to-Beat Blood Pressure Monitor

    Science.gov (United States)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

  13. Red blood cell alloimmunization in transfused patients in sub-Saharan Africa: A systematic review and meta-analysis.

    Science.gov (United States)

    Ngoma, Alain M; Mutombo, Paulin B; Ikeda, Kazuhiko; Nollet, Kenneth E; Natukunda, Bernard; Ohto, Hitoshi

    2016-04-01

    Previous studies of Sub-Saharan Africans show significant alloimmunization to red blood cell (RBC) antigens, but country-specific data are limited. Thus, the aim of this study was to estimate, by meta-analysis, the overall proportion of red blood cell alloantibodies among transfused patients. We systematically searched Medline, Embase, and the Africa-Wide Information database to identify relevant studies in any language. Case reports, comments, letters, conference abstracts, editorials, and review articles were excluded. Of the 269 potentially relevant articles, 11 studies fulfilled our selection criteria. Overall proportions of alloimmunization were 6.7 (95% CI: 5.7, 7.8) per 100 transfused patients. With regard to antibody specificity, among clinically significant antibodies, anti-E ranked as the most common, followed by anti-K, anti-C and anti-D. Meta-analysis of available literature quantifies and qualifies the clinical challenge of RBC alloimmunization among transfused patients in Sub-Saharan Africa. These results should drive policy decisions in favour of routine testing of RBC antigens and irregular antibodies for transfused patients as a standard of care throughout Sub-Saharan Africa. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Quantitative Clinical Diagnostic Analysis of Acetone in Human Blood by HPLC: A Metabolomic Search for Acetone as Indicator

    Directory of Open Access Journals (Sweden)

    Esin Akgul Kalkan

    2016-01-01

    Full Text Available Using high-performance liquid chromatography (HPLC and 2,4-dinitrophenylhydrazine (2,4-DNPH as a derivatizing reagent, an analytical method was developed for the quantitative determination of acetone in human blood. The determination was carried out at 365 nm using an ultraviolet-visible (UV-Vis diode array detector (DAD. For acetone as its 2,4-dinitrophenylhydrazone derivative, a good separation was achieved with a ThermoAcclaim C18 column (15 cm × 4.6 mm × 3 μm at retention time (tR 12.10 min and flowrate of 1 mL min−1 using a (methanol/acetonitrile water elution gradient. The methodology is simple, rapid, sensitive, and of low cost, exhibits good reproducibility, and allows the analysis of acetone in biological fluids. A calibration curve was obtained for acetone using its standard solutions in acetonitrile. Quantitative analysis of acetone in human blood was successfully carried out using this calibration graph. The applied method was validated in parameters of linearity, limit of detection and quantification, accuracy, and precision. We also present acetone as a useful tool for the HPLC-based metabolomic investigation of endogenous metabolism and quantitative clinical diagnostic analysis.

  15. High-performance liquid chromatographic analysis of cyclosporin A in rat blood and liver using a commercially available internal standard.

    Science.gov (United States)

    Chimalakonda, Anjaneya P; Shah, Rakhi B; Mehvar, Reza

    2002-05-25

    All the available HPLC assays of cyclosporin A (CyA) use internal standards that are not commercially available. Our purpose was to develop an HPLC assay for measurements of CyA in rat blood and liver using a commercially available internal standard (I.S.). After the addition of tamoxifen (I.S.), blood (0.25 ml) or the liver homogenate (1 ml) samples were extracted into a mixture of ether:methanol (95:5). The residue after evaporation of the organic layer was dissolved in 200 microl of an injection solution and washed with 1 ml of hexane before analysis. The separation was achieved using an LC-1 column (70 degrees C) with a mobile phase of methanol-acetonitrile-0.01 M KH(2)PO(4) (50:25:25, v/v) and a flow-rate of 1 ml/min. Detection was at 205 nm. Cyclosporin A and I.S. eluted at 5 and 7 min, respectively, free from endogenous peaks. Linear relationships (r>0.98) were observed between the CyA:I.S. peak area ratios and the CyA concentrations within the range of 0.2-10 microg/ml for blood and 0.1-4 microg/ml for the liver homogenates. The intra- and inter-run C.V.s and errors for both the blood and liver samples were <15%. The extraction efficiency (n=5) was close to 100% for both CyA and I.S. in both blood and liver homogenates. The lower limit of quantitation of the assay was 0.2 or 0.1 microg/ml based on 250 microl of blood or 1 ml of liver homogenate, respectively. The assay was capable of measuring blood and liver concentrations of CyA in a rat injected intravenously with a single 5-mg/kg dose of the drug.

  16. Interactions between cadmium and decabrominated diphenyl ether on blood cells count in rats-Multiple factorial regression analysis.

    Science.gov (United States)

    Curcic, Marijana; Buha, Aleksandra; Stankovic, Sanja; Milovanovic, Vesna; Bulat, Zorica; Đukić-Ćosić, Danijela; Antonijević, Evica; Vučinić, Slavica; Matović, Vesna; Antonijevic, Biljana

    2017-02-01

    The objective of this study was to assess toxicity of Cd and BDE-209 mixture on haematological parameters in subacutely exposed rats and to determine the presence and type of interactions between these two chemicals using multiple factorial regression analysis. Furthermore, for the assessment of interaction type, an isobologram based methodology was applied and compared with multiple factorial regression analysis. Chemicals were given by oral gavage to the male Wistar rats weighing 200-240g for 28days. Animals were divided in 16 groups (8/group): control vehiculum group, three groups of rats were treated with 2.5, 7.5 or 15mg Cd/kg/day. These doses were chosen on the bases of literature data and reflect relatively high Cd environmental exposure, three groups of rats were treated with 1000, 2000 or 4000mg BDE-209/kg/bw/day, doses proved to induce toxic effects in rats. Furthermore, nine groups of animals were treated with different mixtures of Cd and BDE-209 containing doses of Cd and BDE-209 stated above. Blood samples were taken at the end of experiment and red blood cells, white blood cells and platelets counts were determined. For interaction assessment multiple factorial regression analysis and fitted isobologram approach were used. In this study, we focused on multiple factorial regression analysis as a method for interaction assessment. We also investigated the interactions between Cd and BDE-209 by the derived model for the description of the obtained fitted isobologram curves. Current study indicated that co-exposure to Cd and BDE-209 can result in significant decrease in RBC count, increase in WBC count and decrease in PLT count, when compared with controls. Multiple factorial regression analysis used for the assessment of interactions type between Cd and BDE-209 indicated synergism for the effect on RBC count and no interactions i.e. additivity for the effects on WBC and PLT counts. On the other hand, isobologram based approach showed slight antagonism

  17. Self-monitoring of blood glucose measurements and glycaemic ...

    African Journals Online (AJOL)

    Background. Intensive diabetes management requires intensive insulin treatment and self-monitoring of blood glucose (SMBG) measurements to obtain immediate information on the status of the blood glucose level and to obtain data for pattern analysis on which meal planning, insulin and lifestyle adjustments can be ...

  18. Preoperative Acute Normovolemic Hemodilution for Minimizing Allogeneic Blood Transfusion: A Meta-Analysis.

    Science.gov (United States)

    Zhou, Xuelong; Zhang, Chenjing; Wang, Yin; Yu, Lina; Yan, Min

    2015-12-01

    Previous studies have evaluated the efficacy of preoperative acute normovolemic hemodilution (PANH) in reducing the need for allogeneic blood transfusion. However, the results to date have been controversial. In this study, we sought to reassess the efficacy and safety of PANH based on newly emerging evidence. Medline, EMBASE, ISI Web of Knowledge, and Cochrane Central Register of Controlled Trials databases were searched using the key words "hemodilution," "autotransfusion," or "hemorrhage" to retrieve all randomized controlled trials examining the benefits of PANH compared with control patients not undergoing PANH in any type of surgery. Sixty-three studies involving 3819 patients were identified. The risk of requiring an allogeneic blood transfusion and the overall volume of allogeneic red blood cell transfused during the perioperative period were reduced in the PANH group compared with the control group (relative risk, 0.74; 95% confidence interval, 0.63 to 0.88; P = 0.0006; weighted mean difference, -0.94 units; 95% confidence interval, -1.27 to -0.61 units; P transfusion. Perioperative blood loss, adverse events, and the length of hospitalization were comparable between these groups. Although these results suggest that PANH is effective in reducing allogeneic blood transfusion, we identified significant heterogeneity and publication bias, which raises concerns about the true efficacy of PANH.

  19. Development of a method for the analysis of perfluoroalkylated compounds in whole blood

    Energy Technology Data Exchange (ETDEWEB)

    Kaerrman, A.; Bavel, B. van; Lindstroem, G. [Oerebro Univ. (Sweden). Man-Technology-Environmental Research Centre; Jaernberg, U. [Stockholm Univ. (Sweden). Inst. of Applied Environmental Research

    2004-09-15

    The commercialisation of interfaced high performance liquid chromatography mass spectrometry (HPLC-MS) facilitated selective and sensitive analysis of perfluoroalkylated (PFA) acids, a group of compounds frequently used for example as industrial surfactants and which are very persistent and biologically active, in a more convenient way than before. Since then a number of reports on PFA compounds found in humans and wildlife have been published. The most used technique for the analysis of perfluoroalkylated compounds has been ion-pair extraction followed by high performance liquid chromatography (HPLC) and negative electrospray tandem mass spectrometry (MS/MS). Tetrabutylammonium ion as the counter ion in the ion-pair extraction has been used together with GC-analysis, LC-fluorescence and LC-MS/MS. Recently, solid phase extraction (SPE) has been used instead of ion-pair extraction for the extraction of human serum. Previously reported studies on human exposure have mainly been on serum, probably because there are indications that PFA acids bind to plasma proteins. We here present a fast and simple method that involves SPE and which is suitable for extracting whole blood samples. Further more, 13 PFAs were included in the method, which uses HPLC and single quadropole mass spectrometry.

  20. Analysis of Blood Transfusion Data Using Bivariate Zero-Inflated Poisson Model: A Bayesian Approach.

    Science.gov (United States)

    Mohammadi, Tayeb; Kheiri, Soleiman; Sedehi, Morteza

    2016-01-01

    Recognizing the factors affecting the number of blood donation and blood deferral has a major impact on blood transfusion. There is a positive correlation between the variables "number of blood donation" and "number of blood deferral": as the number of return for donation increases, so does the number of blood deferral. On the other hand, due to the fact that many donors never return to donate, there is an extra zero frequency for both of the above-mentioned variables. In this study, in order to apply the correlation and to explain the frequency of the excessive zero, the bivariate zero-inflated Poisson regression model was used for joint modeling of the number of blood donation and number of blood deferral. The data was analyzed using the Bayesian approach applying noninformative priors at the presence and absence of covariates. Estimating the parameters of the model, that is, correlation, zero-inflation parameter, and regression coefficients, was done through MCMC simulation. Eventually double-Poisson model, bivariate Poisson model, and bivariate zero-inflated Poisson model were fitted on the data and were compared using the deviance information criteria (DIC). The results showed that the bivariate zero-inflated Poisson regression model fitted the data better than the other models.

  1. Optimized multiparametric flow cytometric analysis of circulating endothelial cells and their subpopulations in peripheral blood of patients with solid tumors: a technical analysis.

    Science.gov (United States)

    Zhou, Fangbin; Zhou, Yaying; Yang, Ming; Wen, Jinli; Dong, Jun; Tan, Wenyong

    2018-01-01

    Circulating endothelial cells (CECs) and their subpopulations could be potential novel biomarkers for various malignancies. However, reliable enumerable methods are warranted to further improve their clinical utility. This study aimed to optimize a flow cytometric method (FCM) assay for CECs and subpopulations in peripheral blood for patients with solid cancers. An FCM assay was used to detect and identify CECs. A panel of 60 blood samples, including 44 metastatic cancer patients and 16 healthy controls, were used in this study. Some key issues of CEC enumeration, including sample material and anticoagulant selection, optimal titration of antibodies, lysis/wash procedures of blood sample preparation, conditions of sample storage, sufficient cell events to enhance the signal, fluorescence-minus-one controls instead of isotype controls to reduce background noise, optimal selection of cell surface markers, and evaluating the reproducibility of our method, were integrated and investigated. Wilcoxon and Mann-Whitney U tests were used to determine statistically significant differences. In this validation study, we refined a five-color FCM method to detect CECs and their subpopulations in peripheral blood of patients with solid tumors. Several key technical issues regarding preanalytical elements, FCM data acquisition, and analysis were addressed. Furthermore, we clinically validated the utility of our method. The baseline levels of mature CECs, endothelial progenitor cells, and activated CECs were higher in cancer patients than healthy subjects ( P technical issues found in previously published assays and validated the reproducibility and sensitivity of our proposed method. Future work is required to explore the potential of our optimized method in clinical oncologic applications.

  2. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, Mudassar; Byrne, James V. [University of Oxford, Nuffield Department of Surgical Sciences, Oxford (United Kingdom)

    2015-09-15

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  3. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    International Nuclear Information System (INIS)

    Kamran, Mudassar; Byrne, James V.

    2015-01-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  4. A simple assay of paracetamol based on dried blood spot suitable ...

    African Journals Online (AJOL)

    Dried blood spots in Guthrie cards are a reliable means of blood sampling suitable for pharmacoki-netic analysis in children. The aim of this study was to develop a simple and reliable bioanalytical method to measure the concentration of paracetamol in dried blood spots. Paracetamol was ex-tracted from dry blood spots by ...

  5. [Efficacy of high versus low plasma: red blood cell ratio resuscitation in patients with severe trauma requiring massive blood transfusion: a meta-analysis].

    Science.gov (United States)

    Yu, Fang; Zhong, Tao; Wu, Gang

    2017-01-20

    To evaluate the efficacy of high (≥1:2) and low (ratio resuscitation in patients with severe trauma requiring massive blood transfusion. The databases including the Cochrane Library, Pubmed, Web of Science, and EMBASE were systemically searched for relevant studies published between January, 2009 and April, 2016. The selection of studies, assessment of methodological quality and data extraction were performed by two researchers independently according to the inclusion and exclusion criteria. The main endpoint was 24-h mortality, 30-day mortality and 24-h survival rate. Five observational studies reporting outcomes of 1024 patients were included in this meta-analysis. Four studies documented civilian cases and one study had a military setting. No significant differences were found in the Injury Severity Score (ISS) between patient groups receiving high and low plasma: RBC ratio resuscitation. Compared with the low-ratio group, the patients with high-ratio resuscitation showed a significant reduction in the 24-h mortality rate (OR=0.35, 95%CI [0.25, 0.48], Pratio resuscitation within the initial 24 h following the trauma (HR=2.34, 95%CI [1.46, 3.73], P=0.00001). Raising the plasma: RBC ratio to 0.5 or higher may decrease the mortality rate of the patients with severe trauma who need massive blood transfusion.

  6. Computer-aided detection of basal cell carcinoma through blood content analysis in dermoscopy images

    Science.gov (United States)

    Kharazmi, Pegah; Kalia, Sunil; Lui, Harvey; Wang, Z. Jane; Lee, Tim K.

    2018-02-01

    Basal cell carcinoma (BCC) is the most common type of skin cancer, which is highly damaging to the skin at its advanced stages and causes huge costs on the healthcare system. However, most types of BCC are easily curable if detected at early stage. Due to limited access to dermatologists and expert physicians, non-invasive computer-aided diagnosis is a viable option for skin cancer screening. A clinical biomarker of cancerous tumors is increased vascularization and excess blood flow. In this paper, we present a computer-aided technique to differentiate cancerous skin tumors from benign lesions based on vascular characteristics of the lesions. Dermoscopy image of the lesion is first decomposed using independent component analysis of the RGB channels to derive melanin and hemoglobin maps. A novel set of clinically inspired features and ratiometric measurements are then extracted from each map to characterize the vascular properties and blood content of the lesion. The feature set is then fed into a random forest classifier. Over a dataset of 664 skin lesions, the proposed method achieved an area under ROC curve of 0.832 in a 10-fold cross validation for differentiating basal cell carcinomas from benign lesions.

  7. The relationship between blood viscosity and blood pressure in a random sample of the population aged 55 to 74 years.

    Science.gov (United States)

    Fowkes, F G; Lowe, G D; Rumley, A; Lennie, S E; Smith, F B; Donnan, P T

    1993-05-01

    Blood viscosity is elevated in hypertensive subjects, but the association of viscosity with arterial blood pressure in the general population, and the influence of social, lifestyle and disease characteristics on this association, are not established. In the Edinburgh Artery Study, 1592 men and women aged 55-74 years selected randomly from the general population attended a university clinic. A fasting blood sample was taken for the measurement of blood viscosity and its major determinants (haematocrit, plasma viscosity and fibrinogen). Systolic pressure was related univariately to blood viscosity (P viscosity (P index. Diastolic pressure was related univariately to blood viscosity (P viscosity (P viscosity and systolic pressure was confined to males. Blood viscosity was associated equally with systolic and diastolic pressures in males, and remained independently related on multivariate analysis adjusting for age, sex, body mass index, social class, smoking, alcohol intake, exercise, angina, HDL and non-HDL cholesterol, diabetes mellitus, plasma viscosity, fibrinogen, and haematocrit.

  8. ABO blood groups and susceptibility to brucellosis.

    Science.gov (United States)

    Mohsenpour, Behzad; Hajibagheri, Katayon; Afrasiabian, Shahla; Ghaderi, Ebrahim; Ghasembegloo, Saeideh

    2015-01-01

    The relationship between blood groups and some infections such as norovirus, cholera, and malaria has been reported. Despite the importance of brucellosis, there is a lack of data on the relationship between blood groups and brucellosis. Thus, in this study, we examined the relationship between blood groups and brucellosis. In this case-control study, the blood groups of 100 patients with brucellosis and 200 healthy individuals were studied. Exclusion criteria for the control group consisted of a positive Coombs Wright test or a history of brucellosis. The chi-square test was used to compare qualitative variables between the two groups. The variables that met inclusion criteria for the regression model were entered into the logistic regression model. A total of 43% patients were female and 57% male; 27% were urban and 73% rural. Regression analysis showed that the likelihood of brucellosis infection was 6.26 times more in people with blood group AB than in those with blood group O (Pblood group and brucellosis. People with blood group AB were susceptible to brucellosis, but no difference was observed for brucellosis infection in terms of blood Rh type.

  9. Effects of blood pressure reduction in mild hypertension : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Sundström, Johan; Arima, Hisatomi; Jackson, Rod; Turnbull, Fiona; Rahimi, Kazem; Chalmers, John; Woodward, Mark; Neal, Bruce; de Zeeuw, Dick

    2015-01-01

    BACKGROUND: Effects of blood pressure reduction in persons with grade 1 hypertension are unclear. PURPOSE: To investigate whether pharmacologic blood pressure reduction prevents cardiovascular events and deaths in persons with grade 1 hypertension. DATA SOURCES: Trials included in the BPLTTC (Blood

  10. Association of sputum and blood eosinophil concentrations with clinical measures of COPD severity: an analysis of the SPIROMICS cohort.

    Science.gov (United States)

    Hastie, Annette T; Martinez, Fernando J; Curtis, Jeffrey L; Doerschuk, Claire M; Hansel, Nadia N; Christenson, Stephanie; Putcha, Nirupama; Ortega, Victor E; Li, Xingnan; Barr, R Graham; Carretta, Elizabeth E; Couper, David J; Cooper, Christopher B; Hoffman, Eric A; Kanner, Richard E; Kleerup, Eric; O'Neal, Wanda K; Paine, Richard; Peters, Stephen P; Alexis, Neil E; Woodruff, Prescott G; Han, MeiLan K; Meyers, Deborah A; Bleecker, Eugene R

    2017-12-01

    Increased concentrations of eosinophils in blood and sputum in chronic obstructive pulmonary disease (COPD) have been associated with increased frequency of exacerbations, reduced lung function, and corticosteroid responsiveness. We aimed to assess whether high eosinophil concentrations in either sputum or blood are associated with a severe COPD phenotype, including greater exacerbation frequency, and whether blood eosinophils are predictive of sputum eosinophils. We did a multicentre observational study analysing comprehensive baseline data from SPIROMICS in patients with COPD aged 40-80 years who had a smoking history of at least 20 pack-years, recruited from six clinical sites and additional subsites in the USA between Nov 12, 2010, and April 21, 2015. Inclusion criteria for this analysis were SPIROMICS baseline visit data with complete blood cell counts and, in a subset, acceptable sputum counts. We stratified patients on the basis of blood and sputum eosinophil concentrations and compared their demographic characteristics, as well as results from questionnaires, clinical assessments, and quantitative CT (QCT). We also analysed whether blood eosinophil concentrations reliably predicted sputum eosinophil concentrations. This study is registered with ClinicalTrials.gov (NCT01969344). Of the 2737 patients recruited to SPIROMICS, 2499 patients were smokers and had available blood counts, and so were stratified by mean blood eosinophil count: 1262 patients with low (George Respiratory Questionnaire symptom scores (p=0·037), and increased wheezing (p=0·018), but no evidence of an association with COPD exacerbations (p=0·35) or the other indices of COPD severity, such as emphysema measured by CT density, COPD assessment test scores, Body-mass index, airflow Obstruction, Dyspnea, and Exercise index, or Global Initiative for Chronic Obstructive Lung Disease stage. Blood eosinophil counts showed a weak but significant association with sputum eosinophil counts

  11. A simple method for measurement of cerebral blood flow using 123I-IMP SPECT with calibrated standard input function by one point blood sampling. Validation of calibration by one point venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Akaizawa, Takashi; Goto, Ryoui

    1994-01-01

    In a simplified method for measurement of cerebral blood flow using one 123 I-IMP SPECT scan and one point arterial blood sampling (Autoradiography method), input function is obtained by calibrating a standard input function by one point arterial blood sampling. A purpose of this study is validation of calibration by one point venous blood sampling as a substitute for one point arterial blood sampling. After intravenous infusion of 123 I-IMP, frequent arterial and venous blood sampling were simultaneously performed on 12 patients of CNS disease without any heart and lung disease and 5 normal volunteers. The radioactivity ratio of venous whole blood which obtained from cutaneous cubital vein to arterial whole blood were 0.76±0.08, 0.80±0.05, 0.81±0.06, 0.83±0.11 at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivities were always 20% lower than those of arterial blood radioactivity during 50 min. However, the ratio which obtained from cutaneous dorsal hand vein to artery were 0.93±0.02, 0.94±0.05, 0.98±0.04, 0.98±0.03, at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivity was consistent with artery. These indicate that arterio-venous difference of radioactivity in a peripheral cutaneous vein like a dorsal hand vein is minimal due to arteriovenous shunt in palm. Therefore, a substitution by blood sampling from cutaneous dorsal hand vein for artery will be possible. Optimized time for venous blood sampling evaluated by error analysis was 20 min after 123 I-IMP infusion, which is 10 min later than that of arterial blood sampling. (author)

  12. Association of adiposity measures with blood lipids and blood pressure in children aged 8-11 years.

    Science.gov (United States)

    Vizcaíno, Vicente Martínez; Aguilar, Fernando Salcedo; Martínez, Montserrat Solera; López, Mairena Sánchez; Gutiérrez, Ricardo Franquelo; Rodríguez-Artalejo, Fernando

    2007-09-01

    To examine the association of body mass index (BMI), triceps skinfold thickness (TST) and percentage body fat (%BF) from bioelectrical impedance analysis (BIA) with blood lipids, systolic blood pressure (SBP) and diastolic blood pressure (DBP) in children. Cross-sectional study was conducted on 1280 schoolchildren aged 8-11 years from the Cuenca province (Spain). Data collection was conducted under standardized conditions, taking several measurements of each variable to enhance accuracy. Analyses were performed using age-adjusted correlation coefficients, and multiple linear regression adjusted for age, BMI, TST and %BF. Correlations between %BF and apolipoprotein (apo) B, total cholesterol, low-density lipoprotein cholesterol (LDL-c), total cholesterol/HDL-c ratio and DBP were higher than those for BMI and TST. In contrast, the correlations between BMI, and apo A-I and SBP were higher than those for %BF and TST. The results were similar across the sexes. The correlations between each of the three measures of body fatness, and blood lipids and blood pressure were highest in children with greatest BMI and %BF. When analyses were adjusted for the three body fatness measures, %BF showed stronger associations than did BMI or TST with blood lipids and blood pressure, with the exception of apo A-I and SBP, which were more closely associated with BMI. %BF from BIA is more strongly associated than either BMI or TST with most of the blood lipid fractions in schoolchildren aged 8-11 years.

  13. Quality Improvement Methodologies Increase Autologous Blood Product Administration

    Science.gov (United States)

    Hodge, Ashley B.; Preston, Thomas J.; Fitch, Jill A.; Harrison, Sheilah K.; Hersey, Diane K.; Nicol, Kathleen K.; Naguib, Aymen N.; McConnell, Patrick I.; Galantowicz, Mark

    2014-01-01

    Abstract: Whole blood from the heart–lung (bypass) machine may be processed through a cell salvaging device (i.e., cell saver [CS]) and subsequently administered to the patient during cardiac surgery. It was determined at our institution that CS volume was being discarded. A multidisciplinary team consisting of anesthesiologists, perfusionists, intensive care physicians, quality improvement (QI) professionals, and bedside nurses met to determine the challenges surrounding autologous blood delivery in its entirety. A review of cardiac surgery patients’ charts (n = 21) was conducted for analysis of CS waste. After identification of practices that were leading to CS waste, interventions were designed and implemented. Fishbone diagram, key driver diagram, Plan–Do–Study–Act (PDSA) cycles, and data collection forms were used throughout this QI process to track and guide progress regarding CS waste. Of patients under 6 kg (n = 5), 80% had wasted CS blood before interventions, whereas those patients larger than 36 kg (n = 8) had 25% wasted CS before interventions. Seventy-five percent of patients under 6 kg who had wasted CS blood received packed red blood cell transfusions in the cardiothoracic intensive care unit within 24 hours of their operation. After data collection and didactic education sessions (PDSA Cycle I), CS blood volume waste was reduced to 5% in all patients. Identification and analysis of the root cause followed by implementation of education, training, and management of change (PDSA Cycle II) resulted in successful use of 100% of all CS blood volume. PMID:24783313

  14. Blood pressure documentation in the emergency department

    Science.gov (United States)

    Daniel, Ana Carolina Queiroz Godoy; Machado, Juliana Pereira; Veiga, Eugenia Velludo

    2017-01-01

    ABSTRACT Objective To analyze the frequency of blood pressure documentation performed by nursing professionals in an emergency department. Methods This is a cross-sectional, observational, descriptive, and analytical study, which included medical records of adult patients admitted to the observation ward of an emergency department, between March and May 2014. Data were obtained through a collection instrument divided into three parts: patient identification, triage data, and blood pressure documentation. For statistical analysis, Pearson’s correlation coefficient was used, with a significance level of α<0.05. Results One hundred fifty-seven records and 430 blood pressure measurements were analyzed with an average of three measurements per patient. Of these measures, 46.5% were abnormal. The mean time from admission to documentation of the first blood pressure measurement was 2.5 minutes, with 42 minutes between subsequent measures. There is no correlation between the systolic blood pressure values and the mean time interval between blood pressure documentations: 0.173 (p=0.031). Conclusion The present study found no correlation between frequency of blood pressure documentation and blood pressure values. The frequency of blood pressure documentation increased according to the severity of the patient and decreased during the length of stay in the emergency department. PMID:28444085

  15. Frequency encoding in renal blood flow regulation

    DEFF Research Database (Denmark)

    Marsh, D.J.; Sosnovtseva, Olga; Pavlov, A.N.

    2005-01-01

    With a model of renal blood flow regulation, we examined consequences of tubuloglomerular feedback (TGF) coupling to the myogenic mechanism via voltage-gated Ca channels. The model reproduces the characteristic oscillations of the two mechanisms and predicts frequency and amplitude modulation...... of the myogenic oscillation by TGF. Analysis by wavelet transforms of single-nephron blood flow confirms that both amplitude and frequency of the myogenic oscillation are modulated by TGF. We developed a double-wavelet transform technique to estimate modulation frequency. Median value of the ratio of modulation...... TGF cycle to the next. We used a blood pressure signal recorded by telemetry from a conscious rat as the input to the model. Blood pressure fluctuations induced variability in the modulation records similar to those found in the nephron blood flow results. Frequency and amplitude modulation can...

  16. The prevalence of HIV among blood donors at Juba Teaching Hospital Blood Bank, South Sudan

    Directory of Open Access Journals (Sweden)

    Kenneth L L Sube

    2014-11-01

    Full Text Available Objectives The aim of this study is to determine the prevalence of HIV among blood donors in Juba Teaching Hospital Blood Bank, South Sudan in 2013. Method and Materials This is a retrospective study that involved the abstraction of data from registers at the blood bank. Data were collected onto data sheets and entered into a computer database. Statistical analysis was performed using SPSS Version 20 Software. A p value of <0.05 was considered statistically significant. Results Out of 1095 blood donors, 1074 (98.1% were males and 21 (1.9% were females. The mean age and the range for the whole group was 29+7.16 (15-69 yrs. The prevalence of HIV was higher among males than females 85 (7.9% vs 1 (4.8% respectively but this was not statistical significant (p=0.6. The 20 to 29 year age group had the highest prevalence of 49 (57% with no statistical significance (p=0.3.The prevalence of HIV was 7.0 % (86 and there were co-infections between HIV and HBV, HCV and syphilis of 14 (50%, 5 (18%, 9 (32% with p=0.7, p=0.1, p=0.8 respectively. Blood group O positive had the highest percentage 58.1 % (n=50 and was the commonest group. Conclusion In this study, HIV prevalence is very high among blood donors at the Juba Teaching Hospital blood bank.

  17. Determination of blood cell subtype concentrations from frozen whole blood samples using TruCount beads.

    Science.gov (United States)

    Langenskiöld, Cecilia; Mellgren, Karin; Abrahamsson, Jonas; Bemark, Mats

    2016-06-24

    In many studies it would be advantageous if blood samples could be collected and analyzed using flow cytometry at a later stage. Ideally, sample collection should involve little hands-on time, allow for long-term storage, and minimally influence the samples. Here we establish a flow cytometry antibody panel that can be used to determine granulocytes, monocytes, and lymphocyte subset concentrations in fresh and frozen whole blood using TruCount technology. The panel can be used on fresh whole-blood samples as well as whole-blood samples that have been frozen after mixing with 10% DMSO. Concentrations in frozen and fresh sample is highly correlated both when frozen within 4 h and the day after collection (r ≥ 0.98), and the estimated concentration in frozen samples was between 91 and 94% of that in fresh samples for all cell types. Using this method whole-blood samples can be frozen using a simple preparation method, and stored long-term before accurate determination of cell concentration. This allows for standardized analysis of the samples at a reference laboratory in multi-center studies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  18. The influence of the non-Newtonian properties of blood on blood-hammer through the posterior cerebral artery.

    Science.gov (United States)

    Tazraei, Pedram; Riasi, Alireza; Takabi, Behrouz

    2015-06-01

    This work investigates a two dimensional numerical analysis of blood hammer through the posterior cerebral artery. The non-Newtonian and usual Newtonian blood models are compared in the case of blood hammer through the posterior cerebral artery to quantify the differences between the models. In this way, a validated CFD simulation is used to study non-Newtonian shear-thinning effects of blood. The governing equations for the modeling of two-dimensional transient flow are solved using a combination of characteristics and central finite difference methods, respectively for the hyperbolic and parabolic parts. Herein, the non-Newtonian viscosity characteristic of blood is incorporated by using the Carreau model. To convert the nonlinear terms available in the characteristics equation into the linear ones, the Newton-Kantorovich method is implemented. The verification and validation of the numerical results are carried out in detail. Hemodynamic characteristics of blood hammer through the posterior cerebral artery are derived with both the Newtonian and non-Newtonian models, and the results are meticulously compared and discussed. The results show that when blood hammer occurs, the non-Newtonian properties greatly influence the velocity and shear stress profiles. At the early stages of blood hammer, there is a 64% difference between magnitudes of wall shear stress in these two models, and the magnitude of the wall shear stress for the shear-thinning blood flow is lower than the Newtonian one. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Adverse reactions to blood donation: A descriptive study of 3520 blood donors in a Nigerian tertiary hospital

    Directory of Open Access Journals (Sweden)

    C Aneke John

    2017-01-01

    Full Text Available Background: The occurrence of adverse reactions to blood donation significantly hampers donor retention and negatively impacts on the universal availability of adequate numbers of blood donor units. Objective: To analyze the spectrum and prevalence of adverse reactions in blood donors in a tertiary hospital-based blood bank in Nigeria. Subjects and Methods: The details of 3520 blood donors who presented for donation over a 12 months period were retrieved from the departmental archives for analysis. These included sociodemographic information, type of donor, type and frequency of adverse reactions to blood donation. Data were analyzed using the Statistical Package for Social Sciences version 20.0 (SPSS Inc., Chicago, IL, USA computer software. Descriptive and inferential statistics were employed to represent the distribution of donor characteristics (as percentages and compare reaction rates by gender and severity, respectively. Results: The prevalence of adverse reactions to blood donation was (56/3520 1.60%; this occurred more frequently in male and family replacement donors (55.35% and 100.0%, respectively. The spectrum of donor adverse reactions included anxiety 25 (44.64%, generalized body weakness 11 (19.64%, hematoma 10 (17.86%, fainting 5 (8.93%, and vomiting 5 (8.93%. Vasovagal reactions were the most frequent adverse reaction encountered among the donors (46/56; 82.14%. Conclusion: Vasovagal reactions are common adverse phenomena in our blood donor set; this has implications on transfusion safety and blood donor retention.

  20. RNA/DNA co-analysis from human menstrual blood and vaginal secretion stains

    DEFF Research Database (Denmark)

    Haas, Claus; Hanson, E; Anjos, M J

    2014-01-01

    housekeeping genes for their suitability as reference genes. Six menstrual blood and six vaginal secretion stains, two dilution series (1/4-1/64 pieces of a menstrual blood/vaginal swab) and, optionally, bona fide or mock casework samples of human or non-human origin were analyzed by 24 participating...

  1. Multispectral Imaging Analysis of Circulating Tumor Cells in Negatively Enriched Peripheral Blood Samples.

    Science.gov (United States)

    Miller, Brandon; Lustberg, Maryam; Summers, Thomas A; Chalmers, Jeffrey J

    2017-01-01

    A variety of biomarkers are present on cells in peripheral blood of patients with a variety of disorders, including solid tumor malignancies. While rare, characterization of these cells for specific protein levels with the advanced technology proposed, will lead to future validation studies of blood samples as "liquid biopsies" for the evaluation of disease status and therapeutic response. While circulating tumor cells (CTCs) have been isolated in the blood samples of patients with solid tumors, the exact role of CTCs as clinically useful predictive markers is still debated. Current commercial technology has significant bias in that a positive selection technology is used that preassumes specific cell surface markers (such as EpCAM) are present on CTCs. However, CTCs with low EpCAM expression have been experimentally demonstrated to be more likely to be missed by this method. In contrast, this application uses a previously developed, technology that performs a purely negative enrichment methodology on peripheral blood, yielding highly enriched blood samples that contain CTCs as well as other, undefined cell types. The focus of this contribution is the use of multispectral imaging of epifluorescent, microscopic images of these enriched cells in order to help develop clinically relevant liquid biopsies from peripheral blood samples.

  2. Quantification of renal cortical blood flow using factor analysis of O-15 water dynamic PET images

    International Nuclear Information System (INIS)

    Seo, Kang Jun; Ahn, Ji Young; Lee, Jae Sung; Paeng, Jin Chul; Cheon, Gi Jeong; Lee, Dong Soo; Noh, Tae Won; Chung, June Key; Lee, Myung Chul

    2000-01-01

    To obtain spatial distribution of renal factor images, input function, and regional tissue time-activity curve (TAC) from O-15 water dynamic PET images non-invasively, factor analysis (FA) was used. O-15 water dynamic PET scans were performed on 3 normal dogs (22 ∼ 29 kg) with the bolus injection of O-15 water (555 ∼ 740 Mbq). We performed FA on the masked dynamic images and obtained the pure TACs and the corresponding factor images. Microsphere experiment also was performed. 37MBq of microsphere labeled with Sc-46 was injected into the left ventricle. Arterial input functions derived from the PET images using FA were compared with the invasively derived arterial blood samples. The renal cortical blood flow using the TACs by FA was within the normal range of 1.23 ∼ 2.46 ml/min/g. In microsphere study, the renal cortical blood flow of left kidney by FA was 2.49±0.47 ml/min/g (1.81∼2.90 ml/min/g) and by microsphere was 2.52 ±0.19 ml/min/g (2.34 ∼2.68 ml/min/g). In right kidney, flow by FA was 2.02 ±0.32 ml/min/g (1.82∼2.49 ml/min/g) and by microsphere was 2.49 ±0.27 ml/min/g (2.02∼2.7). FA is a useful and robust method to extract input functions and tissue TACs from O-15 dynamic renal PET. Renal cortical blood flow can be estimated non-invasively using FA and it will be helpful for the assessment of renal functional disease

  3. Blood Types

    Science.gov (United States)

    ... blood, safe blood transfusions depend on careful blood typing and cross-matching. There are four major blood ... cause exceptions to the above patterns. ABO blood typing is not sufficient to prove or disprove paternity ...

  4. Red blood cell alloimmunization among sickle cell Kuwaiti Arab patients who received red blood cell transfusion.

    Science.gov (United States)

    Ameen, Reem; Al Shemmari, Salem; Al-Bashir, Abdulaziz

    2009-08-01

    Sickle cell disease (SCD) is common in the Arabian Gulf region. Most cases require a red blood cell (RBC) transfusion, increasing the potential for RBC alloantibody development. The incidence of RBC alloimmunization among Kuwaiti Arab SCD patients is not yet known. This study retrospectively assessed the effect of using two different matching protocols on the incidence of alloimmunization among multiply transfused Kuwaiti Arab SCD patients. A total of 233 Kuwaiti Arab SCD patients were divided into two groups: Group 1 (n = 110) received RBC transfusion through standard ABO- and D-matched nonleukoreduced blood; Group 2 (n = 123) received RBCs matched for ABO, Rh, and K1 poststorage-leukoreduced blood. Multivariate analysis was performed on the factors associated with RBC alloimmunization and antibody specificity. Sixty-five percent of patients in Group 1 developed clinically significant RBC alloantibody with an increased prevalence in females; in patients in Group 2, 23.6% developed RBC alloantibodies (p = 0.01). In Group 1, 72 patients (65.5%) had alloantibodies directed against Rh and Kell systems (p = 0.01). Multivariate analysis further confirmed the results, showing that blood transfusion type and sex have significant effects on the rate of alloimmunizations. This study confirms the importance of selecting RBCs matched for Rh and Kell to reduce the risk of alloimmunizations among Kuwaiti Arab SCD patients.

  5. Cost-effectiveness of private umbilical cord blood banking.

    Science.gov (United States)

    Kaimal, Anjali J; Smith, Catherine C; Laros, Russell K; Caughey, Aaron B; Cheng, Yvonne W

    2009-10-01

    To investigate the cost-effectiveness of private umbilical cord blood banking. A decision-analytic model was designed comparing private umbilical cord blood banking with no umbilical cord blood banking. Baseline assumptions included a cost of $3,620 for umbilical cord blood banking and storage for 20 years, a 0.04% chance of requiring an autologous stem cell transplant, a 0.07% chance of a sibling requiring an allogenic stem cell transplant, and a 50% reduction in risk of graft-versus-host disease if a sibling uses banked umbilical cord blood. Private cord blood banking is not cost-effective because it cost an additional $1,374,246 per life-year gained. In sensitivity analysis, if the cost of umbilical cord blood banking is less than $262 or the likelihood of a child needing a stem cell transplant is greater than 1 in 110, private umbilical cord blood banking becomes cost-effective. Currently, private umbilical cord blood banking is cost-effective only for children with a very high likelihood of needing a stem cell transplant. Patients considering private blood banking should be informed of the remote likelihood that a unit will be used for a child or another family member. III.

  6. Image resizing using saliency strength map and seam carving for white blood cell analysis

    Directory of Open Access Journals (Sweden)

    Nam JaeYeal

    2010-09-01

    Full Text Available Abstract Background A new image-resizing method using seam carving and a Saliency Strength Map (SSM is proposed to preserve important contents, such as white blood cells included in blood cell images. Methods To apply seam carving to cell images, a SSM is initially generated using a visual attention model and the structural properties of white blood cells are then used to create an energy map for seam carving. As a result, the energy map maximizes the energies of the white blood cells, while minimizing the energies of the red blood cells and background. Thus, the use of a SSM allows the proposed method to reduce the image size efficiently, while preserving the important white blood cells. Results Experimental results using the PSNR (Peak Signal-to-Noise Ratio and ROD (Ratio of Distortion of blood cell images confirm that the proposed method is able to produce better resizing results than conventional methods, as the seam carving is performed based on an SSM and energy map. Conclusions For further improvement, a faster medical image resizing method is currently being investigated to reduce the computation time, while maintaining the same image quality.

  7. Image resizing using saliency strength map and seam carving for white blood cell analysis.

    Science.gov (United States)

    Ko, ByoungChul; Kim, SeongHoon; Nam, JaeYeal

    2010-09-20

    A new image-resizing method using seam carving and a Saliency Strength Map (SSM) is proposed to preserve important contents, such as white blood cells included in blood cell images. To apply seam carving to cell images, a SSM is initially generated using a visual attention model and the structural properties of white blood cells are then used to create an energy map for seam carving. As a result, the energy map maximizes the energies of the white blood cells, while minimizing the energies of the red blood cells and background. Thus, the use of a SSM allows the proposed method to reduce the image size efficiently, while preserving the important white blood cells. Experimental results using the PSNR (Peak Signal-to-Noise Ratio) and ROD (Ratio of Distortion) of blood cell images confirm that the proposed method is able to produce better resizing results than conventional methods, as the seam carving is performed based on an SSM and energy map. For further improvement, a faster medical image resizing method is currently being investigated to reduce the computation time, while maintaining the same image quality.

  8. Molecular approaches for blood meal analysis and species identification of mosquitoes (Insecta: Diptera: Culicidae) in rural locations in southern England, United Kingdom.

    Science.gov (United States)

    Hernández-Triana, Luis Miguel; Brugman, Victor Albert; Prosser, Sean Williams John; Weland, Chris; Nikolova, Nadya; Thorne, Leigh; Marco, Mar Fernández DE; Fooks, Anthony Richard; Johnson, Nicholas

    2017-04-03

    Thirty-four species of Culicidae are present in the UK, of which 15 have been implicated as potential vectors of arthropod-borne viruses such as West Nile virus. Identification of mosquito feeding preferences is paramount to the understanding of vector-host-pathogen interactions which, in turn, would assist in the control of disease outbreaks. Results are presented on the application of DNA barcoding for vertebrate species identification in blood-fed female mosquitoes in rural locations. Blood-fed females (n = 134) were collected in southern England from rural sites and identified based on morphological criteria. Blood meals from 59 specimens (44%) were identified as feeding on eight hosts: European rabbit, cow, human, barn swallow, dog, great tit, magpie and blackbird. Analysis of the cytochrome c oxidase subunit I mtDNA barcoding region and the internal transcribed spacer 2 rDNA region of the specimens morphologically identified as Anopheles maculipennis s.l. revealed the presence of An. atroparvus and An. messeae. A similar analysis of specimens morphologically identified as Culex pipiens/Cx. torrentium showed all specimens to be Cx. pipiens (typical form). This study demonstrates the importance of using molecular techniques to support species-level identification in blood-fed mosquitoes to maximize the information obtained in studies investigating host feeding patterns.

  9. Study of ABO blood types by combining membrane electrophoresis with surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Wang, Jing; Lin, Juqiang; Huang, Zufang; Sun, Liqing; Shao, Yonghong; Lu, Peng; Shi, Wei; Lin, Jinyong; Chen, Rong

    2012-12-01

    The molecular characterization of ABO blood types, which is clinically significant in blood transfusion, has clinical and anthropological importance. Polymerase chain reaction sequence-based typing (PCR-SBT) is one of the most commonly used methods for the analysis of genetic bases of ABO blood types. However, such methods as PCR-SBT are time-consuming and are high in demand of equipments and manipulative skill. Here we showed that membrane electrophoresis based SERS method employed for studying the molecular bases of ABO blood types can provide rapidand easy-operation with high sensitivity and specificity. The plasma proteins were firstly purified by membrane electrophoresis and then mixed with silver nanoparticles to perform SERS detection. We use this method to classify different blood types, including blood type A (n=13), blood type B (n=9) and blood type O (n=10). Combination of principal component analysis (PCA) and liner discriminant analysis (LDA) was then performed on the SERS spectra of purified albumin, showing good classification results among different blood types. Our experimental outcomes represent a critical step towards the rapid, convenient and accurate identification of ABO blood types.

  10. Variability in blood and blood component utilization as assessed by an anesthesia information management system.

    Science.gov (United States)

    Frank, Steven M; Savage, Will J; Rothschild, Jim A; Rivers, Richard J; Ness, Paul M; Paul, Sharon L; Ulatowski, John A

    2012-07-01

    Data can be collected for various purposes with anesthesia information management systems. The authors describe methods for using data acquired from an anesthesia information management system to assess intraoperative utilization of blood and blood components. Over an 18-month period, data were collected on 48,086 surgical patients at a tertiary care academic medical center. All data were acquired with an automated anesthesia recordkeeping system. Detailed reports were generated for blood and blood component utilization according to surgical service and surgical procedure, and for individual surgeons and anesthesiologists. Transfusion hemoglobin trigger and target concentrations were compared among surgical services and procedures, and between individual medical providers. For all patients given erythrocytes, the mean transfusion hemoglobin trigger was 8.4 ± 1.5, and the target was 10.2 ± 1.5 g/dl. Variation was significant among surgical services (trigger range: 7.5 ± 1.2-9.5 ± 1.1, P = 0.0001; target range: 9.1 ± 1.2-11.3 ± 1.4 g/dl, P = 0.002), surgeons (trigger range: 7.2 ± 0.7-9.8 ± 1.0, P = 0.001; target range: 8.8 ± 0.9-11.8 ± 1.3 g/dl, P = 0.001), and anesthesiologists (trigger range: 7.2 ± 0.8-9.6 ± 1.2, P = 0.001; target range: 9.0 ± 0.9-11.7 ± 1.3 g/dl, P = 0.0004). The use of erythrocyte salvage, fresh frozen plasma, and platelets varied threefold to fourfold among individual surgeons compared with their peers performing the same surgical procedure. The use of data acquired from an anesthesia information management system allowed a detailed analysis of blood component utilization, which revealed significant variation among surgical services and surgical procedures, and among individual anesthesiologists and surgeons compared with their peers. Incorporating these methods of data acquisition and analysis into a blood management program could reduce unnecessary transfusions, an outcome that may increase patient safety and reduce costs.

  11. Development and validation of a magneto-hydrodynamic solver for blood flow analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kainz, W; Guag, J; Krauthamer, V; Myklebust, J; Bassen, H; Chang, I [Center for Devices and Radiological Health, FDA, Silver Spring, MD (United States); Benkler, S; Chavannes, N [Schmid and Partner Engineering AG, Zurich (Switzerland); Szczerba, D; Neufeld, E; Kuster, N [Foundation for Research on Information Technology in Society (IT' IS), Zurich (Switzerland); Kim, J H; Sarntinoranont, M, E-mail: wolfgang.kainz@fda.hhs.go [Soft Tissue Mechanics and Drug Delivery Laboratory, Mechanical and Aerospace Engineering, University of Florida, FL (United States)

    2010-12-07

    The objective of this study was to develop a numerical solver to calculate the magneto-hydrodynamic (MHD) signal produced by a moving conductive liquid, i.e. blood flow in the great vessels of the heart, in a static magnetic field. We believe that this MHD signal is able to non-invasively characterize cardiac blood flow in order to supplement the present non-invasive techniques for the assessment of heart failure conditions. The MHD signal can be recorded on the electrocardiogram (ECG) while the subject is exposed to a strong static magnetic field. The MHD signal can only be measured indirectly as a combination of the heart's electrical signal and the MHD signal. The MHD signal itself is caused by induced electrical currents in the blood due to the moving of the blood in the magnetic field. To characterize and eventually optimize MHD measurements, we developed a MHD solver based on a finite element code. This code was validated against literature, experimental and analytical data. The validation of the MHD solver shows good agreement with all three reference values. Future studies will include the calculation of the MHD signals for anatomical models. We will vary the orientation of the static magnetic field to determine an optimized location for the measurement of the MHD blood flow signal.

  12. Identification and red blood cell automated counting from blood smear images using computer-aided system.

    Science.gov (United States)

    Acharya, Vasundhara; Kumar, Preetham

    2018-03-01

    Red blood cell count plays a vital role in identifying the overall health of the patient. Hospitals use the hemocytometer to count the blood cells. Conventional method of placing the smear under microscope and counting the cells manually lead to erroneous results, and medical laboratory technicians are put under stress. A computer-aided system will help to attain precise results in less amount of time. This research work proposes an image-processing technique for counting the number of red blood cells. It aims to examine and process the blood smear image, in order to support the counting of red blood cells and identify the number of normal and abnormal cells in the image automatically. K-medoids algorithm which is robust to external noise is used to extract the WBCs from the image. Granulometric analysis is used to separate the red blood cells from the white blood cells. The red blood cells obtained are counted using the labeling algorithm and circular Hough transform. The radius range for the circle-drawing algorithm is estimated by computing the distance of the pixels from the boundary which automates the entire algorithm. A comparison is done between the counts obtained using the labeling algorithm and circular Hough transform. Results of the work showed that circular Hough transform was more accurate in counting the red blood cells than the labeling algorithm as it was successful in identifying even the overlapping cells. The work also intends to compare the results of cell count done using the proposed methodology and manual approach. The work is designed to address all the drawbacks of the previous research work. The research work can be extended to extract various texture and shape features of abnormal cells identified so that diseases like anemia of inflammation and chronic disease can be detected at the earliest.

  13. Donor Hemovigilance Programme in managing Blood Transfusion Needs: Complications of Whole Blood Donation

    Directory of Open Access Journals (Sweden)

    S Mangwana

    2013-10-01

    Full Text Available Background: Hemovigilance like quality systems and audits have become an integral part of Blood Transfusion Services in the developed countries and has contributed greatly to its development. Hemovigilance begins with donors and must enable the collection of information on reactions occurring during the donation of blood, selections of donors and to prevent such incidents. The aim of study was to help identify the trends of adverse events , occurring in blood donors at a tertiary-care hospital, to recommend best practices to improve donor care and safety Materials and Methods: This record-based study was conducted on all adverse events related to allogenic whole blood donations performed over 24 months. All whole blood donations were analyzed. All adverse events occurring during or at the end of the donation were noted using a standardized format and analyzed determining significance at p<0.05. Results: Overall rate was 0.3% with vasovagal reactions constituting 82%, and 18% mild syncopal reactions (p<0.001. Immediate vasovagal reaction with injury was very rare (0.007%. Vasovagal reactions showed a significant association with young age, female gender, first time donation status. Mean age of persons recording adverse effects was 30.23 ± 7.49 years as compared to those without adverse effects, 31.14 ± 8.56 years. Conclusion: Donor safety is an essential perquisite to increase voluntary blood donation. AE analysis helps in identifying the blood donors at risk of AE, applying appropriate motivational strategies, predonation counseling, care during and after donation, developing guidelines and hemovigilance programme in countries with limited resources. DOI: http://dx.doi.org/10.3126/jpn.v3i6.8993   Journal of Pathology of Nepal (2013 Vol. 3, 459-463

  14. Blood pressure

    Science.gov (United States)

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  15. An accurate, flexible and small optical fiber sensor: a novel technological breakthrough for real-time analysis of dynamic blood flow data in vivo.

    Directory of Open Access Journals (Sweden)

    Qiao-ying Yuan

    Full Text Available Because of the limitations of existing methods and techniques for directly obtaining real-time blood data, no accurate microflow in vivo real-time analysis method exists. To establish a novel technical platform for real-time in vivo detection and to analyze average blood pressure and other blood flow parameters, a small, accurate, flexible, and nontoxic Fabry-Perot fiber sensor was designed. The carotid sheath was implanted through intubation of the rabbit carotid artery (n = 8, and the blood pressure and other detection data were determined directly through the veins. The fiber detection results were compared with test results obtained using color Doppler ultrasound and a physiological pressure sensor recorder. Pairwise comparisons among the blood pressure results obtained using the three methods indicated that real-time blood pressure information obtained through the fiber sensor technique exhibited better correlation than the data obtained with the other techniques. The highest correlation (correlation coefficient of 0.86 was obtained between the fiber sensor and pressure sensor. The blood pressure values were positively related to the total cholesterol level, low-density lipoprotein level, number of red blood cells, and hemoglobin level, with correlation coefficients of 0.033, 0.129, 0.358, and 0.373, respectively. The blood pressure values had no obvious relationship with the number of white blood cells and high-density lipoprotein and had a negative relationship with triglyceride levels, with a correlation coefficient of -0.031. The average ambulatory blood pressure measured by the fiber sensor exhibited a negative correlation with the quantity of blood platelets (correlation coefficient of -0.839, P<0.05. The novel fiber sensor can thus obtain in vivo blood pressure data accurately, stably, and in real time; the sensor can also determine the content and status of the blood flow to some extent. Therefore, the fiber sensor can obtain

  16. Frequency of different blood groups and its association with BMI and blood pressure among the female medical students of Faisalabad.

    Science.gov (United States)

    Jawed, Shireen; Zia, Sadaf; Tariq, Sundus

    2017-08-01

    To determine the frequency of different blood groups among female medical students and to find the association of blood groups and body mass index with blood pressure. This cross-sectional study was performed at the University Medical and Dental College, Faisalabad, Pakistan, from March to April 2016, and comprised female medical students. Participants were divided into groups on the basis of their ABO blood groups and on body mass index criteria. Blood groups were determined by simple conventional slide method. Blood pressure was estimated by manual auscultatory technique with a mercury sphygmomanometer. Data was analysed usingSPSS20. There were 145 students with an overall mean age of18.4±0.75 years (range: 17-23 years). Blood group B was the predominant group 65(44.8%). Besides, 130(89.6%) subjects were rhesus positive and 23(53%) subjects of blood group O were pre-hypertensive. Multiple regression analysis indicated significant positive association of blood group O with both systolic and diastolic blood pressure (p=0.002, 0.001). However, subsequent logistic regression showed significant association only with diastolic blood pressure (p=0.001). Relative risk of pre-hypertension for obese (p=0.001) was greater than non-obese subjects. Body mass index was significantly associated with both systolic and diastolic blood pressure (p=0.004, 0.042). Blood group B was the most common blood group. Blood group O was associated with diastolic pre-hypertension, while body mass index was associated with both systolic and diastolic pre-hypertension.

  17. High-speed imaging of blood splatter patterns

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, T.E.; Albright, K.A.; King, N.S.P.; Yates, G.J. (Los Alamos National Lab., NM (United States)); Levine, G.F. (California Dept. of Justice, Sacramento, CA (United States). Bureau of Forensic Services)

    1993-01-01

    The interpretation of blood splatter patterns is an important element in reconstructing the events and circumstances of an accident or crime scene. Unfortunately, the interpretation of patterns and stains formed by blood droplets is not necessarily intuitive and study and analysis are required to arrive at a correct conclusion. A very useful tool in the study of blood splatter patterns is high-speed photography. Scientists at the Los Alamos National Laboratory, Department of Energy (DOE), and Bureau of Forensic Services, State of California, have assembled a high-speed imaging system designed to image blood splatter patterns. The camera employs technology developed by Los Alamos for the underground nuclear testing program and has also been used in a military mine detection program. The camera uses a solid-state CCD sensor operating at approximately 650 frames per second (75 MPixels per second) with a microchannel plate image intensifier that can provide shuttering as short as 5 ns. The images are captured with a laboratory high-speed digitizer and transferred to an IBM compatible PC for display and hard copy output for analysis. The imaging system is described in this paper.

  18. High-speed imaging of blood splatter patterns

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, T.E.; Albright, K.A.; King, N.S.P.; Yates, G.J. [Los Alamos National Lab., NM (United States); Levine, G.F. [California Dept. of Justice, Sacramento, CA (United States). Bureau of Forensic Services

    1993-05-01

    The interpretation of blood splatter patterns is an important element in reconstructing the events and circumstances of an accident or crime scene. Unfortunately, the interpretation of patterns and stains formed by blood droplets is not necessarily intuitive and study and analysis are required to arrive at a correct conclusion. A very useful tool in the study of blood splatter patterns is high-speed photography. Scientists at the Los Alamos National Laboratory, Department of Energy (DOE), and Bureau of Forensic Services, State of California, have assembled a high-speed imaging system designed to image blood splatter patterns. The camera employs technology developed by Los Alamos for the underground nuclear testing program and has also been used in a military mine detection program. The camera uses a solid-state CCD sensor operating at approximately 650 frames per second (75 MPixels per second) with a microchannel plate image intensifier that can provide shuttering as short as 5 ns. The images are captured with a laboratory high-speed digitizer and transferred to an IBM compatible PC for display and hard copy output for analysis. The imaging system is described in this paper.

  19. An optimized hollow microneedle for minimally invasive blood extraction.

    Science.gov (United States)

    Li, Cheng Guo; Lee, Chang Yeol; Lee, Kwang; Jung, Hyungil

    2013-02-01

    The healthcare system relies widely on biochemical information obtained from blood sample extracted via hypodermic needles, despite the invasiveness and pain associated with this procedure. Therefore, an alternative micro-scale needle for minimally invasive blood sampling is highly desirable. Traditional fabrication techniques to create microneedles do not generate needles with the combined features of a sharp tip, long length, and hollow structure concurrently. Here, we report the fabrication of a microneedle long enough to reach blood vessels and sharp enough to minimize nerve contact for minimally invasive blood extraction. The microneedle structure was precisely controlled using a drawing lithography technique, and a sharp tip angle was introduced using a laser-cutting system. We investigated the characteristics of a microneedle with a length of 1,800 μm length, an inner diameter of 60 μm, a tip diameter of 120 μm, and a 15° bevel angle through in-vitro liquid extraction and mechanical strength analysis. We demonstrated that the proposed structure results in blood extraction at a reasonable rate, and that a microneedle with this geometry can reliably penetrate skin without breaking. We integrated this microneedle into a blood extraction device to extract a 20 μl volume of mouse blood in-vivo. Our optimized, hollow microneedle can potentially be incorporated with other cutting-edge technologies such as microactuators, biosensors, and microfluidic chips to create blood analysis systems for point-of-care diagnostics.

  20. Blood wastage management in a regional blood transfusion centre.

    Science.gov (United States)

    Javadzadeh Shahshahani, H; Taghvai, N

    2017-10-01

    The aim of this study was to determine the rate of blood component wastage before and after interventions at Yazd Blood Transfusion Center. The growing need for blood components along with blood safety issues and rising costs constantly pressurise blood centres to improve their efficiency. Reducing the quantity of discarded blood at all stages of the supply chain can decrease the total costs. Data on discarded blood components were extracted from the database of Yazd Blood Transfusion Center. Multiple interventions, including implementation of wastage management standard operating procedures and reduction of red blood cells (RBCs) inventory level, were implemented. Discard rates of blood components in the 3 years after intervention (2013-2015) were compared with the discard rates in the 3 years before interventions. The total wastage rate of blood components decreased by almost 60%. Discard rates of RBCs, platelets and plasma decreased from 9·7%, 18·5% and 5·4% to 2·9%, 10·5% and 2·3%, (P supply saving. © 2017 British Blood Transfusion Society.

  1. Novel approach for deriving genome wide SNP analysis data from archived blood spots

    Science.gov (United States)

    2012-01-01

    Background The ability to transport and store DNA at room temperature in low volumes has the advantage of optimising cost, time and storage space. Blood spots on adapted filter papers are popular for this, with FTA (Flinders Technology Associates) Whatman™TM technology being one of the most recent. Plant material, plasmids, viral particles, bacteria and animal blood have been stored and transported successfully using this technology, however the method of porcine DNA extraction from FTA Whatman™TM cards is a relatively new approach, allowing nucleic acids to be ready for downstream applications such as PCR, whole genome amplification, sequencing and subsequent application to single nucleotide polymorphism microarrays has hitherto been under-explored. Findings DNA was extracted from FTA Whatman™TM cards (following adaptations of the manufacturer’s instructions), whole genome amplified and subsequently analysed to validate the integrity of the DNA for downstream SNP analysis. DNA was successfully extracted from 288/288 samples and amplified by WGA. Allele dropout post WGA, was observed in less than 2% of samples and there was no clear evidence of amplification bias nor contamination. Acceptable call rates on porcine SNP chips were also achieved using DNA extracted and amplified in this way. Conclusions DNA extracted from FTA Whatman cards is of a high enough quality and quantity following whole genomic amplification to perform meaningful SNP chip studies. PMID:22974252

  2. Magnetophoretic separation of blood cells at the microscale

    International Nuclear Information System (INIS)

    Furlani, E P

    2007-01-01

    We present a method and model for the direct and continuous separation of red and white blood cells in plasma. The method is implemented at the microscale using a microfluidic system that consists of an array of integrated soft-magnetic elements embedded adjacent to a microfluidic channel. The microsystem is passive and is activated via application of a bias field that magnetizes the elements. Once magnetized, the elements produce a nonuniform magnetic field distribution in the microchannel, which gives rise to a force on blood cells as they pass through the microsystem. In whole blood, white blood cells behave as diamagnetic microparticles while red blood cells exhibit diamagnetic or paramagnetic behaviour depending on the oxygenation of their haemoglobin. We develop a mathematical model for predicting the motion of blood cells in the microsystem that takes into account the dominant magnetic, fluidic and buoyant forces on the cells. We use the model to study red/white blood cell transport, and our analysis indicates that the microsystem is capable of rapid and efficient red/white blood cell separation

  3. Phosphatidylethanol in Blood as a Marker of Chronic Alcohol Use: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Santo Davide Ferrara

    2012-11-01

    Full Text Available The present paper aims at a systematic review of the current knowledge on phosphatidylethanol (PEth in blood as a direct marker of chronic alcohol use and abuse. In March 2012, the search through “MeSH” and “free-text” protocols in the databases Medline/PubMed, SCOPUS, Web of Science, and Ovid/Embase, combining the terms phosphatidylethanol and alcohol, provided 444 records, 58 of which fulfilled the inclusion criteria and were used to summarize the current evidence on the formation, distribution and degradation of PEth in human blood: (1, the presence and distribution of different PEth molecular species (2, the most diffused analytical methods devoted to PEth identification and quantization (3, the clinical efficiency of total PEth quantification as a marker of chronic excessive drinking (4, and the potential utility of this marker for identifying binge drinking behaviors (5. Twelve papers were included in the meta-analysis and the mean (M and 95% confidence interval (CI of total PEth concentrations in social drinkers (DAI ≤ 60 g/die; M = 0.288 µM; CI 0.208–0.367 µM and heavy drinkers (DAI > 60 g/die; M = 3.897 µM; CI 2.404–5.391 µM were calculated. The present analysis demonstrates a good clinical efficiency of PEth for detecting chronic heavy drinking.

  4. Phosphatidylethanol in Blood as a Marker of Chronic Alcohol Use: A Systematic Review and Meta-Analysis

    Science.gov (United States)

    Viel, Guido; Boscolo-Berto, Rafael; Cecchetto, Giovanni; Fais, Paolo; Nalesso, Alessandro; Ferrara, Santo Davide

    2012-01-01

    The present paper aims at a systematic review of the current knowledge on phosphatidylethanol (PEth) in blood as a direct marker of chronic alcohol use and abuse. In March 2012, the search through “MeSH” and “free-text” protocols in the databases Medline/PubMed, SCOPUS, Web of Science, and Ovid/Embase, combining the terms phosphatidylethanol and alcohol, provided 444 records, 58 of which fulfilled the inclusion criteria and were used to summarize the current evidence on the formation, distribution and degradation of PEth in human blood: (1), the presence and distribution of different PEth molecular species (2), the most diffused analytical methods devoted to PEth identification and quantization (3), the clinical efficiency of total PEth quantification as a marker of chronic excessive drinking (4), and the potential utility of this marker for identifying binge drinking behaviors (5). Twelve papers were included in the meta-analysis and the mean (M) and 95% confidence interval (CI) of total PEth concentrations in social drinkers (DAI ≤ 60 g/die; M = 0.288 μM; CI 0.208–0.367 μM) and heavy drinkers (DAI > 60 g/die; M = 3.897 μM; CI 2.404–5.391 μM) were calculated. The present analysis demonstrates a good clinical efficiency of PEth for detecting chronic heavy drinking. PMID:23203094

  5. Analysis of blood flow patterns in aortic aneurysm by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Matsuoka, Hiroshi

    1993-01-01

    Cine MRI (0.5 T) using rephased gradient echo technique was performed to study the patterns of blood flow in the aortic aneurysm of 16 patients with aortic aneurysm, and the data were compared with those of 5 healthy volunteers. In the transaxial section, the blood flow in normal aorta appeared as homogeneous high intensity during systole. On the other hand, the blood flow in the aneurysm appeared as inhomogeneous flow enhancement with flow void. In the sagittal scan, the homogeneous flow enhancement in a normal aorta was also observed during systole and its apex of flow enhancement was 'taper'. The blood flow patterns in the aneurysm were classified as 'irregular', 'zonal', 'eddy', and 'obscure' depending on the contrast of flow enhancement and flow void. Their apexes were 'taper' or 'round'. The blood flow patterns in the aneurysm were related to the size of aneurysm. In patients with a large size 'aneurysm, their flow patterns were 'eddy' or 'obscure' and the flow enhancement was 'round'. On the other hand, in patients with a small size aneurysm, their flow patterns were 'irregular' or 'zonal', and their flow enhancement was 'taper'. Though the exact mechanism of abnormal flow patterns in an aortic aneurysm remains to be determined, cine MRI gives helpful informations in assessing blood flow dynamics in the aneurysm. (author)

  6. Donating Blood

    Science.gov (United States)

    ... The medical history includes questions that help blood bank staff decide if a person is healthy enough to donate blood. They'll ... Food and Drug Administration (FDA) regulates U.S. blood banks. All blood ... operating. Sometimes people who donate blood notice a few minor side ...

  7. Cost-effectiveness of Intensive Blood Pressure Management

    DEFF Research Database (Denmark)

    Richman, Ilana B; Fairley, Michael; Jørgensen, Mads Emil

    2016-01-01

    Importance: Among high-risk patients with hypertension, targeting a systolic blood pressure of 120 mm Hg reduces cardiovascular morbidity and mortality compared with a higher target. However, intensive blood pressure management incurs additional costs from treatment and from adverse events......-effectiveness of intensive blood pressure management among 68-year-old high-risk adults with hypertension but not diabetes. We used the Systolic Blood Pressure Intervention Trial (SPRINT) to estimate treatment effects and adverse event rates. We used Centers for Disease Control and Prevention Life Tables to project age...... and accrued $155 261 in lifetime costs, while intensive management yielded 10.5 QALYs and accrued $176 584 in costs. Intensive blood pressure management cost $23 777 per QALY gained. In a sensitivity analysis, serious adverse events would need to occur at 3 times the rate observed in SPRINT and be 3 times...

  8. Handheld Microfluidic Blood Ananlyzer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Nanohmics proposes to develop a handheld blood analyzer for micro- and hypo-gravity missions. The prototype instrument will combine impedance analysis with optical...

  9. Screening of gingival crevicular blood glucose and capillary finger blood glucose in the diagnosis of diabetes

    Directory of Open Access Journals (Sweden)

    Alka S Waghmare

    2011-01-01

    Full Text Available Aim: The study aimed at obtaining glucose readings using gingival crevicular blood (GCB to screen for undiagnosed diabetes during routine dental visits. Materials and Methods: The present study included 50 patients who were divided into two groups, i.e. Group A and Group B, based on bleeding on probing at the site of collection of GCB. Group A participants had blood collected from sites having adequate bleeding on probing, whereas Group B participants had blood collected from sites with little bleeding on probing. GCB and capillary finger-stick blood (CFB] glucose readings were obtained using a self-monitoring glucometer. Statistical Analysis: Correlations between both the samples were done using Pearson′s correlation. Results: Group A patients′ correlations between GCB and CFB glucose readings were high, whereas in Group B patients, correlations between glucose readings were low. Conclusion: GCB can be an excellent source for screening diabetes during routine dental visits.

  10. Cytogenetical analysis in blood lymphocytes of cigarette smokers in ...

    African Journals Online (AJOL)

    Comet assay showed increased percentage of abnormalities in smokers (light, medium and heavy) than non-smokers. Conclusion: The frequencies of MN in buccal epithelial and blood lymphocytes are high in smokers; particularly heavy smoker group showed significantly increased results. Among them, the lymphocytic ...

  11. Cord Blood

    Directory of Open Access Journals (Sweden)

    Saeed Abroun

    2014-05-01

    Full Text Available   Stem cells are naïve or master cells. This means they can transform into special 200 cell types as needed by body, and each of these cells has just one function. Stem cells are found in many parts of the human body, although some sources have richer concentrations than others. Some excellent sources of stem cells, such as bone marrow, peripheral blood, cord blood, other tissue stem cells and human embryos, which last one are controversial and their use can be illegal in some countries. Cord blood is a sample of blood taken from a newborn baby's umbilical cord. It is a rich source of stem cells, umbilical cord blood and tissue are collected from material that normally has no use following a child’s birth. Umbilical cord blood and tissue cells are rich sources of stem cells, which have been used in the treatment of over 80 diseases including leukemia, lymphoma and anemia as bone marrow stem cell potency.  The most common disease category has been leukemia. The next largest group is inherited diseases. Patients with lymphoma, myelodysplasia and severe aplastic anemia have also been successfully transplanted with cord blood. Cord blood is obtained by syringing out the placenta through the umbilical cord at the time of childbirth, after the cord has been detached from the newborn. Collecting stem cells from umbilical blood and tissue is ethical, pain-free, safe and simple. When they are needed to treat your child later in life, there will be no rejection or incompatibility issues, as the procedure will be using their own cells. In contrast, stem cells from donors do have these potential problems. By consider about cord blood potency, cord blood banks (familial or public were established. In IRAN, four cord blood banks has activity, Shariati BMT center cord blood bank, Royan familial cord blood banks, Royan public cord blood banks and Iranian Blood Transfusion Organ cord blood banks. Despite 50,000 sample which storage in these banks, but the

  12. Myocardial blood flow quantification by Rb-82 cardiac PET/CT: A detailed reproducibility study between two semi-automatic analysis programs.

    OpenAIRE

    Dunet, V.; Klein, R.; Allenbach, G.; Renaud, J.; deKemp, R.A.; Prior, J.O.

    2016-01-01

    Background Several analysis software packages for myocardial blood flow (MBF) quantification from cardiac PET studies exist, but they have not been compared using concordance analysis, which can characterize precision and bias separately. Reproducible measurements are needed for quantification to fully develop its clinical potential. Methods Fifty-one patients underwent dynamic Rb-82 PET at rest and during adenosine stress. Data were processed with PMOD and FlowQuant (Lortie model). MBF and m...

  13. Associations of blood lead, cadmium, and mercury with estimated glomerular filtration rate in the Korean general population: Analysis of 2008-2010 Korean National Health and Nutrition Examination Survey data

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yangho [Department of Occupational and Environmental Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan (Korea, Republic of); Lee, Byung-Kook, E-mail: bklee@sch.ac.kr [Institute of Environmental and Occupational Medicine, Soonchunhyang University 646 Eupnae-ri, Shinchang-myun, Asan-si, Choongnam 336-745 (Korea, Republic of)

    2012-10-15

    Introduction: The objective of this study was to evaluate associations between blood lead, cadmium, and mercury levels with estimated glomerular filtration rate in a general population of South Korean adults. Methods: This was a cross-sectional study based on data obtained in the Korean National Health and Nutrition Examination Survey (KNHANES) (2008-2010). The final analytical sample consisted of 5924 participants. Estimated glomerular filtration rate (eGFR) was calculated using the MDRD Study equation as an indicator of glomerular function. Results: In multiple linear regression analysis of log2-transformed blood lead as a continuous variable on eGFR, after adjusting for covariates including cadmium and mercury, the difference in eGFR levels associated with doubling of blood lead were -2.624 mL/min per 1.73 m Superscript-Two (95% CI: -3.803 to -1.445). In multiple linear regression analysis using quartiles of blood lead as the independent variable, the difference in eGFR levels comparing participants in the highest versus the lowest quartiles of blood lead was -3.835 mL/min per 1.73 m Superscript-Two (95% CI: -5.730 to -1.939). In a multiple linear regression analysis using blood cadmium and mercury, as continuous or categorical variables, as independent variables, neither metal was a significant predictor of eGFR. Odds ratios (ORs) and 95% CI values for reduced eGFR calculated for log2-transformed blood metals and quartiles of the three metals showed similar trends after adjustment for covariates. Discussion: In this large, representative sample of South Korean adults, elevated blood lead level was consistently associated with lower eGFR levels and with the prevalence of reduced eGFR even in blood lead levels below 10 {mu}g/dL. In conclusion, elevated blood lead level was associated with lower eGFR in a Korean general population, supporting the role of lead as a risk factor for chronic kidney disease.

  14. [Central blood pressure and vascular damage].

    Science.gov (United States)

    Pérez-Lahiguera, Francisco; Rodilla, Enrique; Costa, José Antonio; Pascual, José María

    2015-07-20

    The aim of this study was to assess the relationship between central blood pressure and vascular damage. This cross-sectional study involved 393 never treated hypertensive patients (166 women). Clinical blood pressure (BP), 24h blood pressure (BP24h) and central blood pressure (CBP) were measured. Vascular organ damage (VOD) was assessed by calculating the albumin/creatinine ratio (ACR), wave pulse pressure velocity and echocardiographic left ventricular mass index (LVMI). Patients with VOD had higher values of BP, BP24h, and CBP than patients without ACR. When comparing several systolic BP, systolic BP24h had a higher linear correlation with CBP (Z Steiger test: 2.26; P=.02) and LVMI (Z Steiger test: 3.23; P=.01) than PAC. In a multiple regression analysis corrected by age, sex and metabolic syndrome, all pressures were related with VOD but systolic BP24h showed the highest correlation. In a logistic regression analysis, having the highest tercile of systolic BP24h was the stronger predictor of VOD (multivariate odds ratio: 3.4; CI 95%: 2.5-5.5, P=.001). CBP does not have more correlation with VOD than other measurements of peripheral BP. Systolic BP24h is the BP measurement that best predicts VOD. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  15. Quantitative Analysis of Regional Cerebral Blood Flow using {sup 99m}Tc-HMPAO SPECT in Parkinson's Disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Chul; Bae, Sang Kyun; Chung, June Key; Koh, Chang Soon; Roh, Jae Kyu; Myung, Ho Jin [Seoul National University College of Medicine, Seoul (Korea, Republic of); Lee, Myung Hae [Asan Medical Center, Seoul (Korea, Republic of)

    1992-07-15

    Regional cerebral blood flow were measured in 10 patients with Parkinson's disease and 12 normal persons using {sup 99m}Tc-HMPAO SPECT. Reconstructed images were interpreted qualitatively and were compared with those findings of CT. For the quantitative analysis, six pairs of region of interest matched with the perfusion territories of large cerebral arteries and cerebellar hemisphere were determined. From the count values, indices showing the degree of asymmetry between right and left cerebral or cerebellar hemisphere, cerebral asymmetry index (ASI) and percent index of cerebellar asymmetry (PIA), and an index showing change of each region, region to cerebellum ratio (RCR) were obtained. ASI of normal persons and patients were 0.082 +- 0.033 and 0.108 +- 0.062, respectively and PIA were -0.4 +- 0.7% and -0.7 +- 1.0%, respectively, which showed no statistically significant difference between normal persons and patients. Among 10 RCR's, those of both regions of basal ganglia and both regions of anterior cerebral artery were significantly reduced. We concluded that the most significant reduction of regional cerebral blood flow in patients with Parkinson's disease was observed in the regions of basal ganglia and in the regions of anterior cerebral artery, and the degree of change in hemispheric blood flow was similar in both hemisphere.

  16. Blood volume studies

    International Nuclear Information System (INIS)

    Lewis, S.M.; Yin, J.A.L.

    1986-01-01

    The use of dilution analysis with such radioisotopes as 51 Cr, 32 P, sup(99m)Tc and sup(113m)In for measuring red cell volume is reviewed briefly. The use of 125 I and 131 I for plasma volume studies is also considered and the subsequent determination of total blood volume discussed, together with the role of the splenic red cell volume. Substantial bibliography. (UK)

  17. Blood lead levels and chronic blood loss

    Energy Technology Data Exchange (ETDEWEB)

    Manci, E.A.; Cabaniss, M.L.; Boerth, R.C.; Blackburn, W.R.

    1986-03-01

    Over 90% of lead in blood is bound to the erythrocytes. This high affinity of lead for red cells may mean that chronic blood loss is a significant means for excretion of lead. This study sought correlations between blood lead levels and clinical conditions involving chronic blood loss. During May, June and July, 146 patients with normal hematocrits and red cell indices were identified from the hospital and clinic populations. For each patient, age, race, sex and medical history were noted, and a whole blood sample was analyzed by flameless atomic absorption spectrophotometry. Age-and race-matched pairs showed a significant correlation of chronic blood loss with lead levels. Patients with the longest history of blood loss (menstruating women) had the lowest level (mean 6.13 ..mu..g/dl, range 3.6-10.3 ..mu..g/dl). Post-menopausal women had levels (7.29 ..mu..g/dl, 1.2-14 ..mu..g/dl) comparable to men with peptic ulcer disease, or colon carcinoma (7.31 ..mu..g/dl, 5.3-8.6 ..mu..g/dl). The highest levels were among men who had no history of bleeding problems (12.39 ..mu..g/dl, 2.08-39.35 ..mu..g/dl). Chronic blood loss may be a major factor responsible for sexual differences in blood lead levels. Since tissue deposition of environmental pollutants is implicated in diseases, menstruation may represent a survival advantage for women.

  18. Prehospital point of care testing of blood gases and electrolytes — an evaluation of IRMA

    OpenAIRE

    Prause, Gerhard; Ratzenhofer-Komenda, Beatrice; Offner, Anton; Lauda, Peter; Voit, Henrika; Pojer, Horst

    1997-01-01

    Background: This study evaluated the feasibility of blood gas analysis and electrolyte measurements during emergency transport prior to hospital admission. Results: A portable, battery-powered blood analyzer was used on patients in life threatening conditions to determine pH, pCO2, pO2, sodium, potassium and ionized calcium. Arterial blood was used for blood gas analysis and electrolyte measurements. Venous blood was used for electrolyte measurement alone. During the observation period of 4 m...

  19. Hypertension. Age-specificity of blood-pressure-associated complications

    OpenAIRE

    Staessen, Jan A

    2014-01-01

    In an analysis of electronic health records, 1.25 million patients aged ≥30 years without diagnosed cardiovascular disease experienced 83,098 cardiovascular events during follow-up (median 5.2 years). Associations between incident cardiovascular disease and blood pressure differed for systolic and diastolic blood pressures and between the 12 cardiovascular end points examined.

  20. Blood-alcohol proficiency test program

    Science.gov (United States)

    1975-01-01

    A preliminary survey has been performed to ascertain the validity of the blood alcohol analysis performed by a number of laboratories on a voluntary basis. Values of accuracy and precision of the tests are presented. /Abstract from report summary pag...

  1. Comparative effects of different dietary approaches on blood pressure in hypertensive and pre-hypertensive patients: A systematic review and network meta-analysis.

    Science.gov (United States)

    Schwingshackl, Lukas; Chaimani, Anna; Schwedhelm, Carolina; Toledo, Estefania; Pünsch, Marina; Hoffmann, Georg; Boeing, Heiner

    2018-05-02

    Pairwise meta-analyses have shown beneficial effects of individual dietary approaches on blood pressure but their comparative effects have not been established. Therefore we performed a systematic review of different dietary intervention trials and estimated the aggregate blood pressure effects through network meta-analysis including hypertensive and pre-hypertensive patients. PubMed, Cochrane CENTRAL, and Google Scholar were searched until June 2017. The inclusion criteria were defined as follows: i) Randomized trial with a dietary approach; ii) hypertensive and pre-hypertensive adult patients; and iii) minimum intervention period of 12 weeks. In order to determine the pooled effect of each intervention relative to each of the other intervention for both diastolic and systolic blood pressure (SBP and DBP), random effects network meta-analysis was performed. A total of 67 trials comparing 13 dietary approaches (DASH, low-fat, moderate-carbohydrate, high-protein, low-carbohydrate, Mediterranean, Palaeolithic, vegetarian, low-GI/GL, low-sodium, Nordic, Tibetan, and control) enrolling 17,230 participants were included. In the network meta-analysis, the DASH, Mediterranean, low-carbohydrate, Palaeolithic, high-protein, low-glycaemic index, low-sodium, and low-fat dietary approaches were significantly more effective in reducing SBP (-8.73 to -2.32 mmHg) and DBP (-4.85 to -1.27 mmHg) compared to a control diet. According to the SUCRAs, the DASH diet was ranked the most effective dietary approach in reducing SBP (90%) and DBP (91%), followed by the Palaeolithic, and the low-carbohydrate diet (ranked 3rd for SBP) or the Mediterranean diet (ranked 3rd for DBP). For most comparisons, the credibility of evidence was rated very low to moderate, with the exception for the DASH vs. the low-fat dietary approach for which the quality of evidence was rated high. The present network meta-analysis suggests that the DASH dietary approach might be the most effective dietary measure

  2. Renal blood flow dynamics in inbred rat strains provides insight into autoregulation.

    Science.gov (United States)

    A Mitrou, Nicholas G; Cupples, William A

    2014-01-01

    Renal autoregulation maintains stable renal blood flow in the face of constantly fluctuating blood pressure. Autoregulation is also the only mechanism that protects the delicate glomerular capillaries when blood pressure increases. In order to understand autoregulation, the renal blood flow response to changing blood pressure is studied. The steadystate response of blood flow is informative, but limits investigation of the individual mechanisms of autoregulation. The dynamics of autoregulation can be probed with transfer function analysis. The frequency-domain analysis of autoregulation allows investigators to probe the relative activity of each mechanism of autoregulation. We discuss the methodology and interpretation of transfer function analysis. Autoregulation is routinely studied in the rat, of which there are many inbred strains. There are multiple strains of rat that are either selected or inbred as models of human pathology. We discuss relevant characteristics of Brown Norway, Spontaneously hypertensive, Dahl, and Fawn-Hooded hypertensive rats and explore differences among these strains in blood pressure, dynamic autoregulation, and susceptibility to hypertensive renal injury. Finally we show that the use of transfer function analysis in these rat strains has contributed to our understanding of the physiology and pathophysiology of autoregulation and hypertensive renal disease.Interestingly all these strains demonstrate effective tubuloglomerular feedback suggesting that this mechanism is not sufficient for effective autoregulation. In contrast, obligatory or conditional failure of the myogenic mechanism suggests that this component is both necessary and sufficient for autoregulation.

  3. A simple assay of paracetamol based on dried blood

    African Journals Online (AJOL)

    User

    Dried blood spots in Guthrie cards are a reliable means of blood sampling suitable for pharmacoki- netic analysis in .... pers were then packed in plastic bags and stored at. 4ºC in the ..... of paracetamol and its metabolites in urine, plasma and ...

  4. Spatial Temporal Image Correlation Spectroscopy (STICS) for Flow Analysis with Application for Blood Flow Mapping

    International Nuclear Information System (INIS)

    Rossow, Molly; Gratton, Enrico; Mantulin, William M.

    2009-01-01

    It is important for surgeons to be able to measure blood flow in exposed arterioles during surgery. We report our progress in the development of an optical technique that will measure blood flow in surgically exposed blood vessels and enable previously difficult measurements. By monitoring optical fluctuations, the optical technique, based on Spatial Temporal Image Correlation (STICS), will directly measure the velocity of micron-scale particles--such as red blood cells. It will complement existing technology and provide qualitative measurements that were not previously possible. It relies on the concept that blood, when viewed on a small enough scale, is an inhomogeneous substance. Individual blood cells passing between a near-infrared light source and a detector will cause fluctuations in the transmitted optical signal. The speed, direction, and flow pattern of blood cells can be determined from these optical fluctuations. We present a series of computer simulations and experiments on phantom and animal systems to test this technique's ability to map complex flow patterns.

  5. Complete blood count reference values of cord blood in Taiwan and the influence of gender and delivery route on them.

    Science.gov (United States)

    Chang, Yu-Hsun; Yang, Shang-Hsien; Wang, Tso-Fu; Lin, Teng-Yi; Yang, Kuo-Liang; Chen, Shu-Huey

    2011-06-01

    Cord blood banking has become more popular in recent years. Checking cord blood complete blood count (CBC) and white blood cell (WBC) differential counts (DCs) is essential before cryopreserving the cord blood units. Therefore, establishing the normal reference values of cord blood CBC and WBC DC is important in clinical practice and research. To obtain a large-scale population-based normal CBC and WBC DC reference values of healthy neonates' cord blood from a public cord blood bank and to investigate the influence of the gender and delivery route. From September 2001 to November 2006, the cord blood of healthy Taiwanese neonates with gestational age 36 weeks and more were collected by Tzu Chi Cord Blood Bank with written informed consents. All cord blood samples were analyzed by Sysmex XE2100 automated hematology analyzer (Sysmex Corporation, Kobe, Japan) to obtain the CBC. The WBC DC was calculated by manual method. We used Student's t test and Mann-Whitney U test for investigating the influences of gender and delivery route on the CBC and WBC DC reference values. The results were presented by mean±standard deviation or 2.5-97.5th percentiles. In the study period, totally 5602 cord blood samples were collected eligibly for analysis. The cord blood CBC and WBC DC normal reference values were calculated. The female neonates had significantly higher mean corpuscular volume, platelet count, and WBC count, but lower red blood cell (RBC) count, hemoglobin (Hb), hematocrit, and mean corpuscular Hb concentration values (pTaiwan. Gender and delivery routes were important confounding factors that influenced the cord blood CBC and WBC DC values. Copyright © 2011. Published by Elsevier B.V.

  6. Outcome analysis of hemoglobin A1c, weight, and blood pressure in a VA diabetes education program.

    Science.gov (United States)

    North, Susan L; Palmer, Glen A

    2015-01-01

    To determine the effect of a specific diabetes education class (Basics) on hemoglobin A1c values, weight, and systolic blood pressure. In this retrospective study, the researchers compared 2 groups of male veterans with a recent diagnosis of type 2 diabetes. One group received diabetes group education (n = 175) over a 4-month period, and the other received standard diabetes management follow-up (n = 184). Outpatient clinic setting in the Midwest. Basics class compared with standard level of care. Pre- and post-laboratory values for hemoglobin A1c, weight, and systolic blood pressure. Multivariate analysis of covariance and follow-up univariate statistics for significant differences. Findings revealed significant differences in hemoglobin A1c (P education curriculum and reduction of hemoglobin A1c values. Some participants also had added benefit of significant weight loss. Published by Elsevier Inc.

  7. Dengue antibodies in blood donors.

    Science.gov (United States)

    Ribas-Silva, Rejane Cristina; Eid, Andressa Ahmad

    2012-01-01

    Dengue is an urban arbovirus whose etiologic agent is a virus of the genus Flavorius with four distinct antigen serotypes (DENV-1, DENV-2, DENV-3 and DENV-4) that is transmitted to humans through the bite of the mosquito Aedes aegypti. The Campo Mourão region in Brazil is endemic for dengue fever. OBTECTIVE: The aim of this study was to evaluate the presence of IgG and IgM antibodies specific to the four serotypes of dengue in donors of the blood donor service in the city of Campo Mourão. Epidemiological records were evaluated and 4 mL of peripheral blood from 213 blood donors were collected in tubes without anticoagulant. Serum was then obtained and immunochromatographic tests were undertaken (Imuno-Rápido Dengue IgM/IgG(TM)). Individuals involved in the study answered a social and epidemiological questionnaire on data which included age, gender and diagnosis of dengue. Only three (1.4%) of the 213 blood tests were positive for IgG anti-dengue antibodies. No donors with IgM antibody, which identifies acute infection, were identified. The results of the current analysis show that the introduction of quantitative or molecular serological methods to determine the presence of anti-dengue antibodies or the detection of the dengue virus in blood donors in endemic regions should be established so that the quality of blood transfusions is guaranteed.

  8. [Correlation analysis of the pre-pregnant body mass index, the gestational weight gain and umbilical cord blood C peptide].

    Science.gov (United States)

    Chen, X L; Han, Y; Zhao, X M; Liu, Y; Lü, J J

    2017-01-03

    Objective: To explore the correlation among the pre-pregnant body mass index (BMI), gestational weight gain (GWG) and umbilical cord blood C peptide, and to investigate the influence of maternal weight management on the incidence of baby long-term metabolic syndrome. Methods: During May to Aug.2015, 485 pregnant women in Zhejiang Taizhou first people's hospital and Taizhou Huangyan maternal &child care service centre were selected in random and divided into four groups according to pre-pregnant BMI: low body mass, normal body mass, over body mass and obese group, and also divided into two groups for getting gestational diabetes mellitus (GDM) or not. According to the gestational weight gain (GWG), all the cases were divided into two groups: above the Institute Of Medicine (IMO) 2009 recommendations or not. According to the outcome, the GDM group which had received weight control treatment, was divided into successful treat group or not. At last, we tested the umbilical cord blood C peptide and birth weight of each newborn and compared the difference in all subgroups. The correlation between the umbilical cord blood C peptide and birth weight were analysed. Results: (1) In the pre-pregnant BMI groups, there were significant differences of incidence of GDM ( P 0.05). (2) Newborn birth weight and the umbilical cord blood C peptide were positively correlated ( r =0.673, P newborn birth weight in all subgroups. (4) All groups showed correlations with neonatal umbilical cord blood C peptide, the GDM mostly (β=0.58), pre-pregnant BMI secondly (β: 0.36, 0.38) , and GWG weakly (β=0.17). (5) By stratification analysis, in GDM group, low body mass was negatively correlated with umbilical cord blood C peptide ( P gestational weight gain and umbilical cord blood C peptide. Suitable maternal weight control especially pre-pregnant body mass index control will lower the baby long-term metabolic syndrome incidence.

  9. Selling blood and gametes during tough economic times: insights from Google search.

    Science.gov (United States)

    Wu, Jonathan A; Ngo, Tin C; Rothman, Cappy; Breyer, Benjamin N; Eisenberg, Michael L

    2015-10-01

    To use Google Insights search volume and publicly available economic indicators to test the hypothesis that sperm, egg, and blood donations increase during economic downturns and to demonstrate the feasibility of using Google search volume data to predict national trends in actual sperm, egg, and blood donations rates. Cross-correlation statistical analysis comparing Google search data for terms relating to blood, egg, and sperm donations with various economic indicators including the S&P 500 closing values, gross domestic product (GDP), the U.S. Index of Leading Indicators (U.S. Leading Index), gross savings rate, mortgage interest rates, unemployment rate, and consumer price index (CPI) from 2004-2011. A secondary analysis determined the Pearson correlation coefficient between Google search data with actual sperm, egg, and blood donation volume in the U.S. as measured by California Cryobank, the National Assisted Reproductive Technology Surveillance System, and the National Blood Collection and Utilization Survey, respectively. Significance of cross-correlation and Pearson correlation analysis as indicated by p value. There were several highly significant cross-correlation relationships between search volume and various economic indicators. Correlation between Google search volume for the term 'sperm donation,' 'egg donation,' and 'blood donation' with actual number of sperm, egg and blood donations in the United States demonstrated Pearson correlation coefficients of 0.2 (p > 0.10), -0.1 (p > 0.10), and 0.07 (p > 0.10), respectively. Temporal analysis showed an improved correlation coefficient of 0.9 (p Google search volume. Google search volume data for search terms relating to sperm, egg, and blood donation increase during economic downturns. This finding suggests gamete and bodily fluid donations are influenced by market forces like other commodities. Google search may be useful for predicting blood donation trends but is more limited in predicting actual

  10. Clinical effects of blood donor characteristics in transfusion recipients: protocol of a framework to study the blood donor-recipient continuum.

    Science.gov (United States)

    Chassé, Michaël; McIntyre, Lauralyn; Tinmouth, Alan; Acker, Jason; English, Shane W; Knoll, Greg; Forster, Alan; Shehata, Nadine; Wilson, Kumanan; van Walraven, Carl; Ducharme, Robin; Fergusson, Dean A

    2015-01-19

    When used appropriately, transfusion of red blood cells (RBCs) is a necessary life-saving therapy. However, RBC transfusions have been associated with negative outcomes such as infection and organ damage. Seeking explanations for the beneficial and deleterious effects of RBC transfusions is necessary to ensure the safe and optimal use of this precious resource. This study will create a framework to analyse the influence of blood donor characteristics on recipient outcomes. We will conduct a multisite, longitudinal cohort study using blood donor data routinely collected by Canadian Blood Services, and recipient data from health administrative databases. Our project will include a thorough validation of primary data, the linkage of various databases into one large longitudinal database, an in-depth epidemiological analysis and a careful interpretation and dissemination of the results to assist the decision-making process of clinicians, researchers and policymakers in transfusion medicine. Our primary donor characteristic will be age of blood donors and our secondary donor characteristics will be donor-recipient blood group compatibility and blood donor sex. Our primary recipient outcome will be a statistically appropriate survival analysis post-RBC transfusion up to a maximum of 8 years. Our secondary recipient outcomes will include 1-year, 2-year and 5-year mortality; hospital and intensive care unit length of stay; rehospitalisation; new cancer and cancer recurrence rate; infection rate; new occurrence of myocardial infarctions and need for haemodialysis. Our results will help determine whether we need to tailor transfusion based on donor characteristics, and perhaps this will improve patient outcome. Our results will be customised to target the different stakeholders involved with blood transfusions and will include presentations, peer-reviewed publications and the use of the dissemination network of blood supply organisations. We obtained approval from the

  11. Analysis of different anthropometric indicators in the detection of high blood pressure in school adolescents: a cross-sectional study with 8295 adolescents.

    Science.gov (United States)

    Christofaro, Diego G D; Farah, Breno Q; Vanderlei, Luiz Carlos M; Delfino, Leandro D; Tebar, William R; Barros, Mauro Virgílio G de; Ritti-Dias, Raphael M

    High blood pressure is strongly associated with obesity in different populations. However, it is unclear whether different anthropometric indicators of obesity can satisfactorily predict high blood pressure in the school setting. This study evaluated the sensitivity and specificity of body mass index, waist circumference, and waist to height ratio in the detection of high blood pressure in adolescents. The sample consisted of 8295 adolescents aged 10-17 years. Weight was measured using a digital scale, height with a stadiometer, and waist circumference using a tape measure. Blood pressure was measured by an automatic blood pressure measuring device. ROC curves were used for the analysis of sensitivity and specificity of the three anthropometric indices in identifying high blood pressure. Binary Logistic Regression was used to assess the association of body mass index, waist circumference, and waist to height ratio with high blood pressure. Low values of sensitivity were observed for body mass index (0.35), waist circumference (0.37), and waist to height ratio (0.31) and high values of specificity for body mass index (0.86), waist circumference (0.82), and waist to height ratio (0.83) in the detection of high blood pressure. An association was observed between adolescents classified with high body mass index (OR=3.57 [95% CI=3.10-4.10]), waist cirumference (OR=3.24 [95% CI=2.83-3.72]), and waist to height ratio (OR=2.94 [95% CI=2.54-3.40]) with high blood pressure. Body mass index, waist circumference, and waist to height ratio presented low sensitivity to identify adolescents with high blood pressure. However, adolescents classified with high body mass index, waist circumference, and waist to height ratio demonstrated a high association of presenting high blood pressure. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  12. Hip Resurfacing Arthroplasty and Perioperative Blood Testing

    Directory of Open Access Journals (Sweden)

    Andrew Cook

    2014-01-01

    Full Text Available It is standard practice in many institutions to routinely perform preoperative and postoperative haemoglobin level testing in association with hip joint arthroplasty procedures. It is our observation, however, that blood transfusion after uncomplicated primary hip arthroplasty in healthy patients is uncommon and that the decision to proceed with blood transfusion is typically made on clinical grounds. We therefore question the necessity and clinical value of routine perioperative blood testing about the time of hip resurfacing arthroplasty. We present analysis of perioperative blood tests and transfusion rates in 107 patients undertaking unilateral hybrid hip resurfacing arthroplasty by the senior author at a single institution over a three-year period. We conclude that routine perioperative testing of haemoglobin levels for hip resurfacing arthroplasty procedures does not assist in clinical management. We recommend that postoperative blood testing only be considered should the patient demonstrate clinical signs of symptomatic anaemia or if particular clinical circumstances necessitate.

  13. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  14. Blood alcohol analysis alone versus comprehensive toxicological analysis - Systematic investigation of missed co-ingested other drugs in suspected alcohol-impaired drivers.

    Science.gov (United States)

    Steuer, Andrea E; Eisenbeiss, Lisa; Kraemer, Thomas

    2016-10-01

    Driving under the influence of alcohol and/or drugs (DUID) is a safety issue of increasing public concern. When a police officer has reasonable grounds to classify a driver as impaired, he may arrange for a blood sample to be taken. In many countries, alcohol analysis only is ordered if impairment is suspected to be exclusively due to alcohol while comprehensive toxicological screening will be performed if additional suspicion for other illegal drugs of abuse (DoA) or medicinal drugs is on hand. The aim of the present study was firstly to evaluate whether signs of impairment can be differentiated to be caused by alcohol alone or a combination of alcohol and other driving-impairing drugs and secondly to which extent additional drugs are missed in suspected alcohol-impaired drivers. A total of 293 DUID cases (negative n=41; alcohol positive only, n=131; alcohol+active drug positive, n=121) analyzed in 2015 in the Canton of Zurich were evaluated for their documented impairment symptoms by translating these into a severity score and comparing them applying principle component analysis (PCA). Additional 500 cases suspected for alcohol-impaired driving only were reanalyzed using comprehensive LC-MS/MS screening methods covering about 1500 compounds. Drugs detected were classified for severity of driving impairment using the classification system established in the DRUID study of the European Commission. As partly expected from the pharmacological and toxicological point of view, PCA analysis revealed no differences between signs of impairment caused by alcohol alone and those caused by alcohol plus at least one active drug. Breaking it down to different blood alcohol concentration ranges, only between 0.3 and 0.5g/kg trends could be observed in terms of more severe impairment for combined alcohol and drug intake. In the 500 blood samples retrospectively analyzed in this study, a total of 330 additional drugs could be detected; in some cases up to 9 co-ingested ones. In

  15. Trace element analysis of human blood serum by neutron activation analysis

    International Nuclear Information System (INIS)

    Nakahara, H.; Nagame, Y.; Yoshizawa, Y.; Oda, H.; Gotoh, S.; Murakami, Y.

    1979-01-01

    An attempt was made to determine if there is any correlation between trace element concentrations in human blood serum and some specific diseases. The serum samples of the patients suffering from cancer, Down syndrome, and Banti syndrome were analyzed by the neutron activation method and compared with the trace element concentrations observed among clinically healthy men. The cancer patients had concentrations in Rb, Mn, Fe, Co, Cu, Zn, Al and Se below normal. The Down syndrome patients were found to have similar deficiencies in Cr, Mn, Fe, Co, Zn, Cu and Sb. (author)

  16. Recovery of Unrelated Donors of Peripheral Blood Stem Cells versus Bone Marrow: A Prespecified Analysis from the Phase III BMT CTN Protocol 0201

    Science.gov (United States)

    Burns, Linda J.; Logan, Brent R.; Chitphakdithai, Pintip; Miller, John P.; Drexler, Rebecca; Spellman, Stephen; Switzer, Galen E.; Wingard, John R.; Anasetti, Claudio; Confer, Dennis L.

    2016-01-01

    We report a comparison of time to recovery, side effects, and change in blood counts from baseline to post-donation of unrelated donors who participated in the Blood and Marrow Transplant Clinical Trials Network (BMT CTN) phase III randomized, multicenter trial (0201) in which donor/recipient pairs were randomized to either peripheral blood stem cell (PBSC) or bone marrow (BM) donation. Of the entire cohort, 262 donated PBSC and 264 donated BM; 372 (71%) donors were from domestic and 154 (29%) from international centers (145 German and 9 Canadian). PBSC donors recovered in less time with a median time to recovery of 1 week compared to 2.3 weeks for BM donors. The number of donors reporting full recovery was significantly greater for donors of PBSC than of BM at 1, 2, and 3 weeks and 3 months post-donation. Multivariate analysis showed that PBSC donors were more likely to recover at any time post donation compared to BM donors (HR 2.08 [95% CI 1.73–2.50], pdonor and donation in more recent years. Donors of BM were more likely to report grade 2–4 skeletal pain, body symptoms and fatigue at 1 week post donation. In logistic regression analysis of domestic donors only in which toxicities at peri-collection time points (day 5 filgrastim for PBSC donors and day 2 post-collection of BM donors) could be analyzed, no variable was significantly associated with grade 2–4 skeletal pain, including product donated (BM vs PBSC, OR 1.13 [95% CI 0.74–1.74], p=0.556). Blood counts were impacted by product donated, with mean change from baseline to post-donation being greater for white blood cells, neutrophils, mononuclear cells and platelets in PBSC donors whereas BM donors experienced a greater mean change in hemoglobin. This analysis provided an enhanced understanding of donor events as product donated was independent of physician bias or donor preference. PMID:27013014

  17. Is There an Association between Keloids and Blood Groups?

    Science.gov (United States)

    Mouhari-Toure, Abas; Saka, Bayaki; Kombaté, Koussaké; Akakpo, Sefako; Egbohou, Palakiyem; Tchangaï-Walla, Kissem; Pitche, Palokinam

    2012-01-01

    Objective. The aim of the study is to investigate the possible associations between the blood groups ABO and Rhesus systems and the presence of keloids in patients with black skin. Method. This case-control study was conducted between September 2007 and August 2011 comparing dermatologic outpatients with keloids to matched controls recruited in preanesthetic consultation at Tokoin Teaching Hospital of Lomé (Togo). Results. The distribution of different ABO blood groups and Rhesus blood groups in both groups (cases versus controls) was not significantly different. This distribution of different blood groups was superimposed on the general population of blood donors at the National Blood Transfusion Center of Lomé. Univariate analysis between each blood group and the presence of keloid does not yield any statistically significant association between blood groups and presence of keloids in the subjects. Conclusion. The study shows no significant association between blood groups and the presence of keloids in our patients. Further investigation needs to be conducted to elucidate this hypothesis further by conducting multicenter studies of several ethnic groups.

  18. A smart core-sheath nanofiber that captures and releases red blood cells from the blood

    Science.gov (United States)

    Shi, Q.; Hou, J.; Zhao, C.; Xin, Z.; Jin, J.; Li, C.; Wong, S.-C.; Yin, J.

    2016-01-01

    A smart core-sheath nanofiber for non-adherent cell capture and release is demonstrated. The nanofibers are fabricated by single-spinneret electrospinning of poly(N-isopropylacrylamide) (PNIPAAm), polycaprolactone (PCL) and nattokinase (NK) solution blends. The self-assembly of PNIPAAm and PCL blends during the electrospinning generates the core-sheath PCL/PNIPAAm nanofibers with PNIPAAm as the sheath. The PNIPAAm-based core-sheath nanofibers are switchable between hydrophobicity and hydrophilicity with temperature change and enhance stability in the blood. When the nanofibers come in contact with blood, the NK is released from the nanofibers to resist platelet adhesion on the nanofiber surface, facilitating the direct capture and isolation of red blood cells (RBCs) from the blood above phase-transition temperature of PNIPAAm. Meanwhile, the captured RBCs are readily released from the nanofibers with temperature stimuli in an undamaged manner. The release efficiency of up to 100% is obtained while maintaining cellular integrity and function. This work presents promising nanofibers to effectively capture non-adherent cells and release for subsequent molecular analysis and diagnosis of single cells.A smart core-sheath nanofiber for non-adherent cell capture and release is demonstrated. The nanofibers are fabricated by single-spinneret electrospinning of poly(N-isopropylacrylamide) (PNIPAAm), polycaprolactone (PCL) and nattokinase (NK) solution blends. The self-assembly of PNIPAAm and PCL blends during the electrospinning generates the core-sheath PCL/PNIPAAm nanofibers with PNIPAAm as the sheath. The PNIPAAm-based core-sheath nanofibers are switchable between hydrophobicity and hydrophilicity with temperature change and enhance stability in the blood. When the nanofibers come in contact with blood, the NK is released from the nanofibers to resist platelet adhesion on the nanofiber surface, facilitating the direct capture and isolation of red blood cells (RBCs) from

  19. Perceptions of donors and recipients regarding blood donation.

    Science.gov (United States)

    Conceição, Vander Monteiro da; Araújo, Jeferson Santos; Oliveira, Rafaela Azevedo Abrantes de; Santana, Mary Elizabeth de; Zago, Márcia Maria Fontão

    2016-01-01

    The aim of this study was to identify the perceptions of blood donors and recipients regarding the act of donating blood. This descriptive study with a survey design focuses on subjective and cultural aspects. Twenty donors and 20 recipients in the blood bank at the time of data collection participated in the study. Interviews were analyzed according to deductive thematic analysis. Two themes emerged - perceptions of donors and perceptions of recipients. Both groups saw the act of donating blood as something positive, though donors associated their reports with the experiences of people close to them who needed blood transfusions, while the recipients associated donations with the maintenance of their lives as, for them, a blood transfusion was a necessary medical treatment. Perceptions regarding blood donations are culturally constructed, as the participants associated knowledge acquired in the social world with moral issues and their life experiences. Hence, in addition to helping others, these individuals feel socially and morally rewarded. Copyright © 2016 Associação Brasileira de Hematologia, Hemoterapia e Terapia Celular. Published by Elsevier Editora Ltda. All rights reserved.

  20. Empirical modelling to predict the refractive index of human blood

    Science.gov (United States)

    Yahya, M.; Saghir, M. Z.

    2016-02-01

    Optical techniques used for the measurement of the optical properties of blood are of great interest in clinical diagnostics. Blood analysis is a routine procedure used in medical diagnostics to confirm a patient’s condition. Measuring the optical properties of blood is difficult due to the non-homogenous nature of the blood itself. In addition, there is a lot of variation in the refractive indices reported in the literature. These are the reasons that motivated the researchers to develop a mathematical model that can be used to predict the refractive index of human blood as a function of concentration, temperature and wavelength. The experimental measurements were conducted on mimicking phantom hemoglobin samples using the Abbemat Refractometer. The results analysis revealed a linear relationship between the refractive index and concentration as well as temperature, and a non-linear relationship between refractive index and wavelength. These results are in agreement with those found in the literature. In addition, a new formula was developed based on empirical modelling which suggests that temperature and wavelength coefficients be added to the Barer formula. The verification of this correlation confirmed its ability to determine refractive index and/or blood hematocrit values with appropriate clinical accuracy.

  1. Numerical analysis of the internal flow field in screw centrifugal blood pump based on CFD

    Science.gov (United States)

    Han, W.; Han, B. X.; Y Wang, H.; Shen, Z. J.

    2013-12-01

    As to the impeller blood pump, the high speed of the impeller, the local high shear force of the flow field and the flow dead region are the main reasons for blood damage. The screw centrifugal pump can effectively alleviate the problems of the high speed and the high shear stress for the impeller. The softness and non-destructiveness during the transfer process can effectively reduce the extent of the damage. By using CFD software, the characteristics of internal flow are analyzed in the screw centrifugal pump by exploring the distribution rules of the velocity, pressure and shear deformation rate of the blood when it flows through the impeller and the destructive effects of spiral blades on blood. The results show that: the design of magnetic levitation solves the sealing problems; the design of regurgitation holes solves the problem of the flow dead zone; the magnetic levitated microcirculation screw centrifugal pump can effectively avoid the vortex, turbulence and high shear forces generated while the blood is flowing through the pump. Since the distribution rules in the velocity field, pressure field and shear deformation rate of the blood in the blood pump are comparatively uniform and the gradient change is comparatively small, the blood damage is effectively reduced.

  2. Impact of Physical Activity Interventions on Blood Pressure in Brazilian Populations

    Directory of Open Access Journals (Sweden)

    Vivian Freitas Rezende Bento

    2015-01-01

    Full Text Available Background: High blood pressure is associated with cardiovascular disease, which is the leading cause of mortality in the Brazilian population. Lifestyle changes, including physical activity, are important for lowering blood pressure levels and decreasing the costs associated with outcomes. Objective: Assess the impact of physical activity interventions on blood pressure in Brazilian individuals. Methods: Meta-analysis and systematic review of studies published until May 2014, retrieved from several health sciences databases. Seven studies with 493 participants were included. The analysis included parallel studies of physical activity interventions in adult populations in Brazil with a description of blood pressure (mmHg before and after the intervention in the control and intervention groups. Results: Of 390 retrieved studies, eight matched the proposed inclusion criteria for the systematic review and seven randomized clinical trials were included in the meta-analysis. Physical activity interventions included aerobic and resistance exercises. There was a reduction of -10.09 (95% CI: -18.76 to -1.43 mmHg in the systolic and -7.47 (95% CI: -11.30 to -3.63 mmHg in the diastolic blood pressure. Conclusions: Available evidence on the effects of physical activity on blood pressure in the Brazilian population shows a homogeneous and significant effect at both systolic and diastolic blood pressures. However, the strength of the included studies was low and the methodological quality was also low and/or regular. Larger studies with more rigorous methodology are necessary to build robust evidence.

  3. Rational Clinical Use of Blood and Blood products – A summary

    Directory of Open Access Journals (Sweden)

    D Ghartimagar

    2017-03-01

    Full Text Available Blood transfusion is an essential therapeutic intervention. The main role of the blood centre is to provide safe and timely blood and blood component(s to the patients that will improve the physiological status of the patient. Various blood components can be harvested from a single donation of whole blood. The blood centre ensures that there is an adequate inventory of all blood types and blood components to meet the needs of the patients. The blood centre does donor selection, blood collection, component preparation, screening for transfusion – transmitted infections and blood processing. Serologically compatible blood and components are provided to the patients after meticulous pre-transfusion testing as per the standard protocol. Rational use of blood and blood products means right product is used with the right dose on right time for the right reason.

  4. Efficacy of Blood Sources and Artificial Blood Feeding Methods in Rearing of Aedes aegypti (Diptera: Culicidae) for Sterile Insect Technique and Incompatible Insect Technique Approaches in Sri Lanka.

    Science.gov (United States)

    Gunathilaka, Nayana; Ranathunge, Tharaka; Udayanga, Lahiru; Abeyewickreme, Wimaladharma

    2017-01-01

    Selection of the artificial membrane feeding technique and blood meal source has been recognized as key considerations in mass rearing of vectors. Artificial membrane feeding techniques, namely, glass plate, metal plate, and Hemotek membrane feeding method, and three blood sources (human, cattle, and chicken) were evaluated based on feeding rates, fecundity, and hatching rates of Aedes aegypti . Significance in the variations among blood feeding was investigated by one-way ANOVA, cluster analysis of variance (ANOSIM), and principal coordinates (PCO) analysis. Feeding rates of Ae. aegypti significantly differed among the membrane feeding techniques as suggested by one-way ANOVA ( p feeding technique. Blood feeding rate of Ae. aegypti was higher with human blood followed by cattle and chicken blood, respectively. However, no significant difference was observed from the mosquitoes fed with cattle and human blood, in terms of fecundity, oviposition rate, and fertility as suggested by one-way ANOVA ( p > 0.05). Metal plate method could be recommended as the most effective membrane feeding technique for mass rearing of Ae. aegypti , due to its high feeding rate and cost effectiveness. Cattle blood could be recommended for mass rearing Ae. aegypti .

  5. Development of a miniaturized mass-flow meter for an axial flow blood pump based on computational analysis.

    Science.gov (United States)

    Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi

    2011-09-01

    In order to monitor the condition of patients with implantable left ventricular assist systems (LVAS), it is important to measure pump flow rate continuously and noninvasively. However, it is difficult to measure the pump flow rate, especially in an implantable axial flow blood pump, because the power consumption has neither linearity nor uniqueness with regard to the pump flow rate. In this study, a miniaturized mass-flow meter for discharged patients with an implantable axial blood pump was developed on the basis of computational analysis, and was evaluated in in-vitro tests. The mass-flow meter makes use of centrifugal force produced by the mass-flow rate around a curved cannula. An optimized design was investigated by use of computational fluid dynamics (CFD) analysis. On the basis of the computational analysis, a miniaturized mass-flow meter made of titanium alloy was developed. A strain gauge was adopted as a sensor element. The first strain gauge, attached to the curved area, measured both static pressure and centrifugal force. The second strain gauge, attached to the straight area, measured static pressure. By subtracting the output of the second strain gauge from the output of the first strain gauge, the mass-flow rate was determined. In in-vitro tests using a model circulation loop, the mass-flow meter was compared with a conventional flow meter. Measurement error was less than ±0.5 L/min and average time delay was 0.14 s. We confirmed that the miniaturized mass-flow meter could accurately measure the mass-flow rate continuously and noninvasively.

  6. Study on the alteration of bubaline blood biochemical composition ...

    African Journals Online (AJOL)

    Bubaline blood biochemistry as affected by slaughter was the agenda for this work. Blood samples were collected from 30 buffaloes from abattoirs before and at slaughter. After biochemical and statistical analysis (mean was compared with t-test), it was observed that the albumin, lactate dehydrogenase and creatine kinase ...

  7. Distribution of blood groups in blood donors in the blood bank of Jagdalpur, Bastar district, Chhattisgarh

    Directory of Open Access Journals (Sweden)

    Sachin A Badge

    2017-01-01

    Full Text Available Aims and Objectives: The incidence of ABO and rhesus (Rh groups varies markedly in different races, ethnic groups, and socioeconomic groups in different parts of the world. The frequencies of ABO and Rh blood groups vary from one population to another and time to time in the same region. The present study was carried out to find the distribution of blood group in rural and tribal populations of Bastar district of Chhattisgarh. Materials and Methods: The present retrospective study was carried out at late Shri Baliram Kashyap Memorial Government Medical College and Maharani Hospital blood bank, Jagdalpur, Bastar district, Chhattisgarh, India, during the 2-year period from January 2014 to December 2015. The blood collections were taken from the voluntary donors at outdoor blood donation camp and in-house blood bank as well as from replacement donors at blood bank. Totally 12,852 donors were considered medically fit and accepted for blood donation during the study period. Results: Out of the total 12,852 donors, most of the donors, i.e., 3996 (31.09% were with blood Group O followed by B (30.44%, A (24.95%, and AB (13.52%. Out of the 12,852 blood donors, majority, i.e., 12,779 (99.43% were male and 73 (0.57% were female. Maximum blood donors, i.e., 12,777 (99.42% were Rh positive while only 75 (0.58% were Rh negative. Conclusion: The knowledge of distribution of ABO and Rh blood groups at local and regional levels is helpful in effective management of blood banks and safe blood transfusion services.

  8. Quantitative analysis of optical properties of flowing blood using a photon-cell interactive Monte Carlo code: effects of red blood cells' orientation on light scattering.

    Science.gov (United States)

    Sakota, Daisuke; Takatani, Setsuo

    2012-05-01

    Optical properties of flowing blood were analyzed using a photon-cell interactive Monte Carlo (pciMC) model with the physical properties of the flowing red blood cells (RBCs) such as cell size, shape, refractive index, distribution, and orientation as the parameters. The scattering of light by flowing blood at the He-Ne laser wavelength of 632.8 nm was significantly affected by the shear rate. The light was scattered more in the direction of flow as the flow rate increased. Therefore, the light intensity transmitted forward in the direction perpendicular to flow axis decreased. The pciMC model can duplicate the changes in the photon propagation due to moving RBCs with various orientations. The resulting RBC's orientation that best simulated the experimental results was with their long axis perpendicular to the direction of blood flow. Moreover, the scattering probability was dependent on the orientation of the RBCs. Finally, the pciMC code was used to predict the hematocrit of flowing blood with accuracy of approximately 1.0 HCT%. The photon-cell interactive Monte Carlo (pciMC) model can provide optical properties of flowing blood and will facilitate the development of the non-invasive monitoring of blood in extra corporeal circulatory systems.

  9. Efficient and specific analysis of red blood cell glycerophospholipid fatty acid composition.

    Directory of Open Access Journals (Sweden)

    Sabrina Klem

    Full Text Available BACKGROUND: Red blood cell (RBC n-3 fatty acid status is related to various health outcomes. Accepted biological markers for the fatty acid status determination are RBC phospholipids, phosphatidylcholine, and phosphatidyletholamine. The analysis of these lipid fractions is demanding and time consuming and total phospholipid n-3 fatty acid levels might be affected by changes of sphingomyelin contents in the RBC membrane during n-3 supplementation. AIM: We developed a method for the specific analysis of RBC glycerophospholipids. The application of the new method in a DHA supplementation trial and the comparison to established markers will determine the relevance of RBC GPL as a valid fatty acid status marker in humans. METHODS: Methyl esters of glycerophospholipid fatty acids are selectively generated by a two step procedure involving methanolic protein precipitation and base-catalysed methyl ester synthesis. RBC GPL solubilisation is facilitated by ultrasound treatment. Fatty acid status in RBC glycerophospholipids and other established markers were evaluated in thirteen subjects participating in a 30 days supplementation trial (510 mg DHA/d. OUTCOME: The intra-assay CV for GPL fatty acids ranged from 1.0 to 10.5% and the inter-assay CV from 1.3 to 10.9%. Docosahexaenoic acid supplementation significantly increased the docosahexaenoic acid contents in all analysed lipid fractions. High correlations were observed for most of the mono- and polyunsaturated fatty acids, and for the omega-3 index (r = 0.924 between RBC phospholipids and glycerophospholipids. The analysis of RBC glycerophospholipid fatty acids yields faster, easier and less costly results equivalent to the conventional analysis of RBC total phospholipids.

  10. Profiling analysis of circulating microRNA in peripheral blood of patients with class IV lupus nephritis.

    Directory of Open Access Journals (Sweden)

    Elkin Navarro-Quiroz

    Full Text Available Renal involvement in Systemic Lupus Erythematous (SLE patients is one of the leading causes of morbidity and a significant contributor to mortality. It's estimated that nearly 50% of SLE individuals develop kidney disease in the first year of the diagnosis. Class IV lupus nephritis (LN-IV is the class of lupus nephritis most common in Colombian patients with SLE. Altered miRNAs expression levels have been reported in human autoimmune diseases including lupus. Variations in the expression pattern of peripheral blood circulating miRNAs specific for this class of lupus nephritis could be correlated with the pathophysiological status of this group of individuals. The aim of this study was to evaluate the relative abundance of circulating microRNAs in peripheral blood from Colombian patients with LN-IV. Circulating miRNAs in plasma of patients with diagnosis of LN-IV were compared with individuals without renal involvement (LNN group and healthy individuals (CTL group. Total RNA was extracted from 10 ml of venous blood and subsequently sequenced using Illumina. The sequences were processed and these were analyzed using miRBase and Ensembl databases. Differential gene expression analysis was carried out with edgeR and functional analysis were done with DIANA-miRPath. Analysis was carried out using as variables of selection fold change (≥2 o ≤-2 and false discovery rate (0.05. We identified 24 circulating microRNAs with differential abundance between LN-IV and CTL groups, fourteen of these microRNAs are described for the first time to lupus nephritis (hsa-miR-589-3p, hsa-miR-1260b, hsa-miR-4511, hsa-miR-485-5p, hsa-miR-584-5p, hsa-miR-543, hsa-miR-153-3p, hsa-miR-6087, hsa-miR-3942-5p, hsa-miR-7977, hsa-miR-323b-3p, hsa-miR-4732-3p and hsa-miR-6741-3p. These changes in the abundance of miRNAs could be interpreted as alterations in the miRNAs-mRNA regulatory network in the pathogenesis of LN, preceding the clinical onset of the disease. The findings

  11. Associations of blood lead, cadmium, and mercury with estimated glomerular filtration rate in the Korean general population: Analysis of 2008–2010 Korean National Health and Nutrition Examination Survey data

    International Nuclear Information System (INIS)

    Kim, Yangho; Lee, Byung-Kook

    2012-01-01

    Introduction: The objective of this study was to evaluate associations between blood lead, cadmium, and mercury levels with estimated glomerular filtration rate in a general population of South Korean adults. Methods: This was a cross-sectional study based on data obtained in the Korean National Health and Nutrition Examination Survey (KNHANES) (2008–2010). The final analytical sample consisted of 5924 participants. Estimated glomerular filtration rate (eGFR) was calculated using the MDRD Study equation as an indicator of glomerular function. Results: In multiple linear regression analysis of log2-transformed blood lead as a continuous variable on eGFR, after adjusting for covariates including cadmium and mercury, the difference in eGFR levels associated with doubling of blood lead were −2.624 mL/min per 1.73 m² (95% CI: −3.803 to −1.445). In multiple linear regression analysis using quartiles of blood lead as the independent variable, the difference in eGFR levels comparing participants in the highest versus the lowest quartiles of blood lead was −3.835 mL/min per 1.73 m² (95% CI: −5.730 to −1.939). In a multiple linear regression analysis using blood cadmium and mercury, as continuous or categorical variables, as independent variables, neither metal was a significant predictor of eGFR. Odds ratios (ORs) and 95% CI values for reduced eGFR calculated for log2-transformed blood metals and quartiles of the three metals showed similar trends after adjustment for covariates. Discussion: In this large, representative sample of South Korean adults, elevated blood lead level was consistently associated with lower eGFR levels and with the prevalence of reduced eGFR even in blood lead levels below 10 μg/dL. In conclusion, elevated blood lead level was associated with lower eGFR in a Korean general population, supporting the role of lead as a risk factor for chronic kidney disease.

  12. Structured self monitoring of blood glucose in Iranian people with type 2 diabetes; A cost consequence analysis

    Directory of Open Access Journals (Sweden)

    Aghili Rokhsareh

    2012-09-01

    Full Text Available Abstract Background Self-Monitoring of Blood Glucose (SMBG is considered as a key factor in management of people with diabetes which is a growing and cost demanding health problem. The purpose of this study was to investigate the effect of comprehensive patient management using structured SMBG on metabolic control as well as its cost consequence analysis. Methods Sixty subjects were recruited in an observational study for a period of 6 months. They were provided with the ACCU-CHEK 360° View tool to fill in the values of the 7-point blood glucose profiles in three consecutive days during the study on a monthly basis. Changes in metabolic control were assessed by HbA1c and lipid profile measurement at the beginning and at the end of the study. In addition, cost consequence analysis was done considering different level of health care professionals with or without insurance coverage. The Average Cost Effectiveness Ratio (ACER as well as Cost saving analysis were calculated and compared. Results The analysis showed significant reduction in HbA1c during the 6-month period in all subjects (P = 0.000. Furthermore, a positive effect was observed on lipid profile. The cost of endocrinologist’s visit in private sector was estimated to be 265.76 USD while this figure was149.15 USD for general practitioner in public sector with insurance coverage. Total complications and mortality cost saving was 154.8 USD. The lowest ACER was calculated for intervention with general practitioner in public sector with insurance coverage. Conclusion Structured SMBG results in significant improvement of glycemic status. Moreover, it is more cost saving in public sector with insurance coverage. It seems that general practitioner visits with insurance coverage is the most affordable option for people with type 2 diabetes.

  13. [Situation and perspectives of blood transfusion in Togo].

    Science.gov (United States)

    Ségbéna, A Y; Fétéké, L; Bikandou, B; Awitala, E J; Koura, A G

    2009-01-01

    We report the successive stages of the reorganization of the blood transfusion sector in Togo. The starting point was the elaboration of the national policy of blood transfusion, then the adoption of a decree organizing the sector as well the various decree of application, particularly that related to transfusion good practices. The current policy recommends two poles of qualification of the blood ant its components and the creation of six stations of collection and distribution attached to these poles. The reorganization started with the rehabilitation of the National Blood Transfusion Centre (CNTS) in Lomé. If the problem of human resources is alarming, especially the availability of hemobiologists, the rehabilitation allowed the increase of the blood collection passing from 5272 donations in December 2003 to 18 164 in December 2008. However, the requirement of blood products is satisfied in 50% in all the country. In 2003, 24% of the blood products were rejected for positive viral markers against 8.37% in 2008 in relation with the improvement of blood safety. Efforts must be continued to reinforce it in the CNTS and to make a better selection of the donors at the Regional Blood Transfusion Centre (CRTS) de Sokodé. The analysis of the weak points of the sector (human resource insufficiency, shortage of the blood products, blood safety) made it possible to indicate solutions to improve the sector of blood transfusion sector. Future outcome is funded in the blood transfusion safety development project in Togo financed by the Agence française de développement (AFD, French development agency).

  14. Effects of blood pressure reduction in mild hypertension: a systematic review and meta-analysis.

    Science.gov (United States)

    Sundström, Johan; Arima, Hisatomi; Jackson, Rod; Turnbull, Fiona; Rahimi, Kazem; Chalmers, John; Woodward, Mark; Neal, Bruce

    2015-02-03

    Effects of blood pressure reduction in persons with grade 1 hypertension are unclear. To investigate whether pharmacologic blood pressure reduction prevents cardiovascular events and deaths in persons with grade 1 hypertension. Trials included in the BPLTTC (Blood Pressure Lowering Treatment Trialists' Collaboration) and trials identified from a previous review and electronic database searches. Patients without cardiovascular disease with blood pressures in the grade 1 hypertension range (140 to 159/90 to 99 mm Hg) who were randomly assigned to an active (antihypertensive drug or more intensive regimen) or control (placebo or less intensive regimen) blood pressure-lowering regimen. Individual-patient data from BPLTTC trials and aggregate data from other trials were extracted. Risk of bias was assessed for all trials. Individual-patient data involved 10 comparisons from trials where most patients had diabetes, and aggregate data involved 3 comparisons from trials of patients without diabetes. The average blood pressure reduction was about 3.6/2.4 mm Hg. Over 5 years, odds ratios were 0.86 (95% CI, 0.74 to 1.01) for total cardiovascular events, 0.72 (CI, 0.55 to 0.94) for strokes, 0.91 (CI, 0.74 to 1.12) for coronary events, 0.80 (CI, 0.57 to 1.12) for heart failure, 0.75 (CI, 0.57 to 0.98) for cardiovascular deaths, and 0.78 (CI, 0.67 to 0.92) for total deaths. Results were similar in secondary analyses. Withdrawal from treatment due to adverse effects was more common in the active groups. Blood pressure reductions and numbers of events were small. Blood pressure-lowering therapy is likely to prevent stroke and death in patients with uncomplicated grade 1 hypertension. Swedish Heart-Lung Foundation, Swedish Research Council, Australian Research Council, and National Health and Medical Research Council of Australia.

  15. [Experimental study on two-way application of traditional Chinese medicines capable of promoting blood circulation and removing blood stasis with neutral property in cold and hot blood stasis syndrome I].

    Science.gov (United States)

    Hao, Er-Wei; Deng, Jia-Gang; Du, Zheng-Cai; Yan, Ke; Zheng, Zuo-Wen; Wang, Qin; Huang, Li-Zhen; Bao, Chuan-Hong; Deng, Xiu-Qiong; Lu, Xiao-Yan; Tang, Zhi-Ling

    2012-11-01

    To study the action characteristics of "two-way application and conditioned dominance" of traditional Chinese medicines with neutral property by observing the action characteristic of 10 traditional Chinese medicines capable of promoting blood circulation and removing blood stasis with neutral property in the microcirculation in rats with heat stagnation and blood stasis syndrome. The rat model with heat stagnation and blood stasis syndrome was established by injecting carrageenan and dry yeast, and the rat model with cold stagnation and blood stasis syndrome was built by the body freezing method. Ten traditional Chinese medicines with neutral property, including 5 with hot property and 5 with cold property, were selected for intervention to observe blood flow rate and flow state indicators in rat auricles and make a comparative analysis on action characteristics of traditional Chinese medicines with neutral property. ANOVA showed that among the 10 traditional Chinese medicines with neutral property, 6 such as Typhae Pollen, Sappan Lignum and Vaccariae Semen can obviously increase the blood flow rate (P traditional Chinese medicines with cold property can increase the blood flow rate (P medicines showed no notable effect; among the 5 traditional Chinese medicines with hot property, Carthamus tinctorius and Ligusticum chuanxiong can increase the blood flow rate (P traditional Chinese medicines with natural and cold properties showed similar effect on heat stagnation and blood stasis syndrome and better effect in increasing blood flow rate than those with hot property; those with natural and hot properties showed similar effect and better effect in increasing blood flow rate than those with cold property. Under the condition of heat stagnation and blood stasis syndrome, traditional Chinese medicines with neutral property have the similar action characteristics with those with cold property; wile under the condition of cold stagnation and blood stasis syndrome

  16. Sequential topographical portrayal of myocardial blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Richeson, J.F.; Waag, R.C.; Zwierzynski, D.; Schenk, E.A. (Univ. of Rochester School of Medicine and Dentistry, NY (USA))

    1989-08-01

    Methods to portray myocardial blood flow in a two-dimensional continuum are advantageous in that they allow blood flow history to be overlaid on histological or histochemical descriptions of the consequences of ischemia. We describe here autoradiographic methods that allow such portrayals at three separate times during the evolution of ischemic injury. A computer-based image-analysis system was used to derive such flow maps by taking advantage of the physical characteristics of radioactive isotopes.

  17. Blood and Blood Components: From Similarities to Differences

    Directory of Open Access Journals (Sweden)

    Olivier Garraud

    2018-04-01

    Full Text Available Blood transfusion is made possible because, in most countries and organizations, altruistic individuals voluntarily, anonymously, and generously donate (without compensation either whole blood or separated components that are then processed and distributed by professionals, prior to being allocated to recipients in need. Being part of modern medicine, blood transfusion uses so-called standard blood components when relative to cellular fractions and fresh plasma. However, as will be discussed in this paper, strictly speaking, such so-called labile blood components are not completely standard. Furthermore, the prevalent system based on voluntary, non-remunerated blood donation is not yet universal and, despite claims by the World Health Organization that 100% of blood collection will be derived from altruistic donations by 2020 (postponed to 2025, many obstacles may hinder this ambition, especially when relative to the collection of the enormous amount of plasma destined for fractionation into plasma derivative or drugs. Finally, country organizations also vary due to the economy, sociology, politics, and epidemiology. This paper then, discusses the particulars (of which ethical considerations of blood transfusion diversity and the consequences for donors, patients, and society.

  18. Blood and Blood Components: From Similarities to Differences

    Science.gov (United States)

    Garraud, Olivier; Tissot, Jean-Daniel

    2018-01-01

    Blood transfusion is made possible because, in most countries and organizations, altruistic individuals voluntarily, anonymously, and generously donate (without compensation) either whole blood or separated components that are then processed and distributed by professionals, prior to being allocated to recipients in need. Being part of modern medicine, blood transfusion uses so-called standard blood components when relative to cellular fractions and fresh plasma. However, as will be discussed in this paper, strictly speaking, such so-called labile blood components are not completely standard. Furthermore, the prevalent system based on voluntary, non-remunerated blood donation is not yet universal and, despite claims by the World Health Organization that 100% of blood collection will be derived from altruistic donations by 2020 (postponed to 2025), many obstacles may hinder this ambition, especially when relative to the collection of the enormous amount of plasma destined for fractionation into plasma derivative or drugs. Finally, country organizations also vary due to the economy, sociology, politics, and epidemiology. This paper then, discusses the particulars (of which ethical considerations) of blood transfusion diversity and the consequences for donors, patients, and society. PMID:29686986

  19. Direct analysis of [6,6-(2)H2]glucose and [U-(13)C6]glucose dry blood spot enrichments by LC-MS/MS.

    Science.gov (United States)

    Coelho, Margarida; Mendes, Vera M; Lima, Inês S; Martins, Fátima O; Fernandes, Ana B; Macedo, M Paula; Jones, John G; Manadas, Bruno

    2016-06-01

    A liquid chromatography tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) in a triple-quadrupole scan mode was developed and comprehensively validated for the determination of [6,6-(2)H2]glucose and [U-(13)C6]glucose enrichments from dried blood spots (DBS) without prior derivatization. The method is demonstrated with dried blood spots obtained from rats administered with a primed-constant infusion of [U-(13)C6]glucose and an oral glucose load enriched with [6,6-(2)H2]glucose. The sensitivity is sufficient for analysis of the equivalent to blood and the overall method was accurate and precise for the determination of DBS isotopic enrichments. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Biology of Blood

    Science.gov (United States)

    ... switch to the Professional version Home Blood Disorders Biology of Blood Overview of Blood Resources In This ... Version. DOCTORS: Click here for the Professional Version Biology of Blood Overview of Blood Components of Blood ...