WorldWideScience

Sample records for yttrium-90 glass microspheres

  1. Effects of hepatic arterial yttrium 90 glass microspheres in dogs.

    Science.gov (United States)

    Wollner, I; Knutsen, C; Smith, P; Prieskorn, D; Chrisp, C; Andrews, J; Juni, J; Warber, S; Klevering, J; Crudup, J

    1988-04-01

    A 22-micron glass microsphere called TheraSphere (Theragenics Corp., Atlanta, GA) has been developed in which yttrium 89 oxide is incorporated into the glass matrix and is activated by neutron bombardment to form the beta-emitting isotope yttrium 90 (Y 90) before using the spheres as radiotherapeutic vehicles. The injection of up to 12 times (on a liver weight basis) the anticipated human dose of nonradioactive TheraSphere into the hepatic arteries of dogs was well tolerated and produced clinically silent alterations within centrolobular areas. The hepatic arterial (HA) injection of radioactive TheraSphere also produced portal changes similar to those observed in humans after external beam therapy. While the extent of damage increased with the delivered dose, radiation exposures in excess of 30,000 cGy did not cause total hepatic necrosis and were compatible with survival. No microspheres distributed to the bone marrow and absolutely no myelosuppression was encountered in any animal. Proposed hepatic exposures to humans of 5000 to 10,000 cGy by means of these microspheres, therefore, would appear to be feasible and tolerable. Radiotherapeutic microsphere administration preceded by regional infusion of a radiosensitizing agent and/or immediately following the redistribution of blood flow toward intrahepatic tumor by vasoactive agents can potentially yield a synergistic, highly selective attack on tumors confined to the liver.

  2. The behaviour of selected yttrium containing bioactive glass microspheres in simulated body environments.

    Science.gov (United States)

    Cacaina, D; Ylänen, H; Simon, S; Hupa, M

    2008-03-01

    The study aims at the manufacture and investigation of biodegradable glass microspheres incorporated with yttrium potentially useful for radionuclide therapy of cancer. The glass microspheres in the SiO2-Na2O-P2O5-CaO-K2O-MgO system containing yttrium were prepared by conventional melting and flame spheroidization. The behaviour of the yttrium silicate glass microspheres was investigated under in vitro conditions using simulated body fluid (SBF) and Tris buffer solution (TBS), for different periods of time, according to half-life time of the Y-90. The local structure of the glasses and the effect of yttrium on the biodegradability process were evaluated by Fourier Transform Infrared (FT-IR) spectroscopy and Back Scattered Electron Imaging of Scanning Electron Microscopy (BEI-SEM) equipped with Energy Dispersive X-ray (EDX) analysis. UV-VIS spectrometry and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used for analyzing the release behaviour of silica and yttrium in the two used solutions. The results indicate that the addition of yttrium to a bioactive glass increases its structural stability which therefore, induced a different behaviour of the glasses in simulated body environments.

  3. radio embolization of yttrium 90 glass microspheres in treatment of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    El Fouly, A.H.A.

    2010-01-01

    Hepatocellular carcinoma (HCC) is a common cancer that typically occurs in the setting of cirrhosis and chronic hepatitis virus infections. HCC is considered currently as global problem; its incidence is expected to increase dramatically by the next few decades. More than 90 % of the accidentally diagnosed patients have non resectable tumor. Portal vein thrombosis, diffuse multifocal liver infiltration and large tumor burden are considered to be a great obstacle in front of the modern lines of treatment, even with Child A liver cirrhosis. Transarterial intrahepatic application of Yttrium-90 glass microspheres may allow effective local ablative treatment of patients with intrahepatic advanced hepatocellular carcinoma (HCC) with or without portal vein thrombosis. The aim of this open-label phase II study was to validate evidence on the safety and efficacy of this treatment in an European cohort of patients with locally advanced HCC such as (large tumor burden, multifocal distribution, portal vein thrombosis). And to assess the response rate according to different approved response assessment guidelines (WHO, RECIST and EASL). Patients and Methods Starting from November 2006 till March 2009, one hundred and eight advanced unresectable HCC patients with and without portal vein thrombosis were included in this prospective study. Yttrium-90 microspheres radiotherapy was performed in a lobar fashion through the right or left hepatic artery. In bilobar disease, right and left liver lobe were treated with 4-6 weeks intervals in between. Response rate was assessed according to different international response assessment criteria (WHO, RECIST and EASL) with sequential computed tomography scans till the last clinical visit or death. The safety of this technique was assessed according to the Common Toxicity Criteria version 3

  4. Yttrium-90 microspheres for the treatment of hepatocellular carcinoma.

    Science.gov (United States)

    Geschwind, Jean Francois H; Salem, Riad; Carr, Brian I; Soulen, Michael C; Thurston, Kenneth G; Goin, Kathleen A; Van Buskirk, Mark; Roberts, Carol A; Goin, James E

    2004-11-01

    Unresectable hepatocellular carcinoma is extremely difficult to treat. TheraSphere consists of yttrium-90 (a pure beta emitter) microspheres, which are injected into the hepatic arteries. This article reviews the safety and survival of patients with hepatocellular carcinoma who were treated with yttrium-90 microspheres. Eighty patients were selected from a database of 108 yttrium-90 microsphere-treated patients and were staged by using Child-Pugh, Okuda, and Cancer of the Liver Italian Program scoring systems. Patients were treated with local, regional, and whole-liver approaches. Survival from first treatment was analyzed with Kaplan-Meier and Cox regression methods. Adverse events and complications of treatment were coded by using the Southwest Oncology Group toxicity scoring system. Patients received liver doses ranging from 47 to 270 Gy. Thirty-two patients (40%) received more than 1 treatment. Survival correlated with pretreatment Cancer of the Liver Italian Program scores ( P = .002), as well as with the individual Cancer of the Liver Italian Program components, Child-Pugh class, alpha-fetoprotein levels, and percentage of tumor replacement. Patients classified as Okuda stage I (n = 54) and II (n = 26) had median survival durations and 1-year survival rates of 628 days and 63%, and 384 days and 51%, respectively ( P = .02). One patient died of liver failure judged as possibly related to treatment. Thus, in selected patients with hepatocellular carcinoma, yttrium-90 microsphere treatment is safe and well tolerated. On the basis of these results, a randomized controlled trial is warranted comparing yttrium-90 microsphere treatment with transarterial chemoembolization by using the Cancer of the Liver Italian Program system for prospective stratified randomization.

  5. Yttrium-90 resin microspheres and their use in the treatment of intrahepatic cholangiocarcinoma.

    Science.gov (United States)

    Filippi, Luca; Schillaci, Orazio; Cianni, Roberto; Bagni, Oreste

    2018-04-01

    Intrahepatic cholangiocarcinoma (ICC) is a severe and rapidly progressive hepatic tumor. Surgery is often impracticable due to locally advanced presentation. On the other hand, chemotherapy has demonstrated only limited effectiveness. For these reasons, liver-directed therapies have been successfully applied for treating ICC. In particular, radioembolization with Yttrium-90 ( 90 Y)-labeled spheres has been reported to be a promising therapeutic approach for this neoplasia. Two commercial forms of 90 Y-labeled spheres are available: glass (TheraSphere ® ) and resin (SIR-Spheres ® ) microspheres. The aim of the present paper is to review the existing literature on the use of the resin microspheres for the treatment of unresectable and chemorefractory ICC, focusing on the methodology, clinical applications and side effects.

  6. Yttrium-90 Selective Internal Radiation Therapy with Glass Microspheres for Hepatocellular Carcinoma: Current and Updated Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Edward Wolfgang; Alanis, Lourdes [Division of Interventional Radiology, Department of Radiology, UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095 (United States); Cho, Sung-Ki [Division of Interventional Radiology, Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351 (Korea, Republic of); Saab, Sammy [Division of Hepatology, Department of Medicine, Pfleger Liver Institute, University of California at Los Angeles, Los Angeles, CA 90024 (United States)

    2016-11-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma.

  7. Yttrium-90 selective internal radiation therapy with glass microspheres for hepatocellular carcinoma: Current and updated literature review

    International Nuclear Information System (INIS)

    Lee, Edward Wolfgang; Alanic, Lourdes; Cho, Sung Ki; Saab, Sammy

    2016-01-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma

  8. Yttrium-90 Selective Internal Radiation Therapy with Glass Microspheres for Hepatocellular Carcinoma: Current and Updated Literature Review

    International Nuclear Information System (INIS)

    Lee, Edward Wolfgang; Alanis, Lourdes; Cho, Sung-Ki; Saab, Sammy

    2016-01-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma

  9. Yttrium-90 selective internal radiation therapy with glass microspheres for hepatocellular carcinoma: Current and updated literature review

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Edward Wolfgang; Alanic, Lourdes [Div. of Interventional Radiology, Dept. of Radiology, UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles (United States); Cho, Sung Ki [Div. of Interventional Radiology, Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Saab, Sammy [Div. of Hepatology, Dept. of Medicine, Pfleger Liver Institute, University of California at Los Angeles, Los Angeles (United States)

    2016-07-15

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma.

  10. Yttrium-90 Selective Internal Radiation Therapy with Glass Microspheres for Hepatocellular Carcinoma: Current and Updated Literature Review.

    Science.gov (United States)

    Lee, Edward Wolfgang; Alanis, Lourdes; Cho, Sung-Ki; Saab, Sammy

    2016-01-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma.

  11. Yttrium 90 microspheres for the treatment of hepatocellular carcinoma.

    Science.gov (United States)

    Memon, Khairuddin; Lewandowski, Robert J; Riaz, Ahsun; Salem, Riad

    2013-01-01

    Yttrium-90 microspheres are radioactive particles which are increasingly being employed for treating patients with unresectable hepatocellular carcinoma (HCC). The procedure is called radioembolization. It involves the injection of micron-sized embolic particles loaded with a radioisotope by use of transarterial techniques. Because of the sensitivity of liver parenchyma and relative insensitivity of tumor, external radiation has played a limited role in treating HCC. (90)Y administered via arterial route directs the highly concentrated radiation to the tumor while healthy liver parenchyma is relatively spared due to its preferential blood supply from portal venous blood. This technique has proven useful for the majority of patients with HCC as most of them present in advanced stage, beyond potentially curative options (resection/liver transplantation). (90)Y microspheres can be used in downstaging large tumors to bring within transplantable criteria, in patients with portal venous thrombosis due to tumor invasion and as palliative therapy. There are two available devices for (90)Y administration; TheraSphere® (glass based) and SIR-Spheres® (resin based). The procedure is performed on an outpatient basis. The incidence of complications is comparatively less and may include nausea, fatigue, abdominal pain, hepatic dysfunction, biliary injury, fibrosis, radiation pneumonitis, GI ulcers, and vascular injury; however, these can be avoided by meticulous pretreatment assessment, careful patient selection, and adequate dosimetry. This article explores the technical and clinical aspects of (90)Y radioembolization with keeping emphasis on patient selection, uses, and complications.

  12. Yttrium-90 microsphere induced gastrointestinal tract ulceration

    Directory of Open Access Journals (Sweden)

    Rikabi Ali A

    2008-09-01

    Full Text Available Abstract Background Radiomicrosphere therapy (RT utilizing yttrium-90 (90Y microspheres has been shown to be an effective regional treatment for primary and secondary hepatic malignancies. We sought to determine a large academic institution's experience regarding the extent and frequency of gastrointestinal complications. Methods Between 2004 and 2007, 27 patients underwent RT for primary or secondary hepatic malignancies. Charts were subsequently reviewed to determine the incidence and severity of GI ulceration. Results Three patients presented with gastrointestinal bleeding and underwent upper endoscopy. Review of the pretreatment angiograms showed normal vascular anatomy in one patient, sclerosed hepatic vasculature in a patient who had undergone prior chemoembolization in a second, and an aberrant left hepatic artery in a third. None had undergone prophylactic gastroduodenal artery embolization. Endoscopic findings included erythema, mucosal erosions, and large gastric ulcers. Microspheres were visible on endoscopic biopsy. In two patients, gastric ulcers were persistent at the time of repeat endoscopy 1–4 months later despite proton pump inhibitor therapy. One elderly patient who refused surgical intervention died from recurrent hemorrhage. Conclusion Gastrointestinal ulceration is a known yet rarely reported complication of 90Y microsphere embolization with potentially life-threatening consequences. Once diagnosed, refractory ulcers should be considered for aggressive surgical management.

  13. Microstructure and magnetic properties of yttrium alumina silicate glass microspheres containing iron oxide

    International Nuclear Information System (INIS)

    Sharma, K.; Basak, C.B.; Prajapat, C.L.; Singh, M.R.

    2015-01-01

    Yttrium alumino-silicate glass microspheres have been used for localized delivery of high radiation dose to tissues in the treatment of hepatocellular carcinoma (BCC) and synovitis. 90 Y is a pure beta emitter with beta emission energy of 0.9367 MeV, average penetration range in tissue 2.5 mm, physical half-life of 64.2 h, thus an effective radioisotope for delivering high radiation dose to the tumor. The efficacy of radiotherapy can further be improved if the glass microspheres are doped with magnetic particles for targeted delivery of high radiation dose. Magnetic glass microspheres can also be utilized for cancer treatment using the magnetic heating of tumor cell. The magnetic glass microspheres are obtained from the glasses with nominal composition (64-x) SiO 2 -17Y 2 O 3 -19 Al 2 O 3 -xFe 2 O 3 (x=4-16 mol %). Density of glasses increases from 3.5g/cc to 3.8g/cc as iron oxide content is increased from 4 to 16 mol %. The glass transition temperature and peak crystallization temperature decreases as the iron oxide content increases. T g values of glass samples decreases with increase of Fe 2 O 3 , while SiO 2 content is decreased. SiO 2 is a network forming oxide and a decrease in the network former in glass lead to decrease in thermo-physical properties like T g . The development of ferrimagnetic crystallites in glasses arise from the conversion of iron oxide into magnetite, magnemite and hematite, which is influenced by the structural and ordering of magnetic particles. The microstructure of glass-ceramic exhibited the formation of 50-100 nm size particles. The magnetite and hematite are formed as major crystalline phases. The magnetization values increased with an increase of iron oxide content and attributed to formation of magnetite phase. Results have shown that the glass microspheres with magnetic properties can be used as potential materials for cancer treatment. (author)

  14. Yttrium-90 radioembolization of hepatocellular carcinoma and metastatic disease to the liver.

    Science.gov (United States)

    Lewandowski, Robert J; Salem, Riad

    2006-03-01

    Yttrium-90 ((90)Y) radioembolization is a catheter-based therapy that delivers internal radiation to hepatic tumors in the form of microspheres. (90)Y can be delivered to the hepatic tumor as either a constituent of a glass microsphere, TheraSphere(®), or as a biocompatible resin-based microsphere, SIR-Spheres(®). Once embedded within the tumor microcirculation, these microspheres emit β-radiation at therapeutic levels. While the technical aspects of radioembolization are quite complex, the collective clinical experience presented in the literature supports the use of (90)Y radioembolization for unresectable hepatic malignancies.

  15. Yttrium-90 microspheres (TheraSphere and SIR-Spheres) for the treatment of unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Allison, C

    2007-09-01

    (1) Microspheres containing radioactive yttrium-90 (90Y) are infused into the hepatic artery. These deliver high doses of ionizing radiation to inoperable hepatocellular carcinoma, the most common type of primary liver cancer. (2) Limited evidence from several case series indicates that palliative therapy with 90Y microspheres may reduce tumour size and increase survival time. (3) In some patients, 90Y treatment may result in enough tumour reduction to permit liver resection or transplantation. (4) While 90Y microsphere therapy is generally well tolerated, major complications and several treatment-related deaths have occurred. Improved patient selection criteria and technical changes to microsphere delivery have reduced the risks of complications and death. (5) Patient selection and the technical aspects of 90Y microsphere treatment are complex and require the coordinated expertise of a multidisciplinary team.

  16. Histological Comparison of Kidney Tissue Following Radioembolization with Yttrium-90 Resin Microspheres and Embolization with Bland Microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Suresh de, E-mail: suresh.desilva@unsw.edu.au [Southern Radiology Group, Radiology Department Sutherland Hospital (Australia); Mackie, Simon [Western General Hospital, Department of Urology (United Kingdom); Aslan, Peter [St George Hospital, Department of Urology (Australia); Cade, David [Sirtex Technology Pty Ltd (Australia); Delprado, Warick [Douglass Hanly Moir Pathology (Australia)

    2016-12-15

    BackgroundIntra-arterial brachytherapy with yttrium-90 ({sup 90}Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of {sup 90}Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model.MethodsIn each of six pigs, ~25–33 % of the kidney volume was embolized with {sup 90}Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8–9 weeks after the procedure to assess the locations of the microspheres and extent of tissue necrosis from {sup 90}Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed.ResultsKidneys embolized with {sup 90}Y-radioembolization decreased in mass by 30–70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the {sup 90}Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 10{sup 6}) of bland microspheres.ConclusionThis study showed that radioembolization with {sup 90}Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of {sup 90}Y resin microspheres for the localized treatment of kidney tumors.

  17. Histological Comparison of Kidney Tissue Following Radioembolization with Yttrium-90 Resin Microspheres and Embolization with Bland Microspheres

    International Nuclear Information System (INIS)

    Silva, Suresh de; Mackie, Simon; Aslan, Peter; Cade, David; Delprado, Warick

    2016-01-01

    BackgroundIntra-arterial brachytherapy with yttrium-90 ("9"0Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of "9"0Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model.MethodsIn each of six pigs, ~25–33 % of the kidney volume was embolized with "9"0Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8–9 weeks after the procedure to assess the locations of the microspheres and extent of tissue necrosis from "9"0Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed.ResultsKidneys embolized with "9"0Y-radioembolization decreased in mass by 30–70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the "9"0Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 10"6) of bland microspheres.ConclusionThis study showed that radioembolization with "9"0Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of "9"0Y resin microspheres for the localized treatment of kidney tumors.

  18. Crystallization of Yttrium and Samarium Aluminosilicate Glasses

    OpenAIRE

    Lago, Diana Carolina; Prado, Miguel Oscar

    2016-01-01

    Aluminosilicate glasses containing samarium and yttrium (SmAS and YAS glasses) exhibit high glass transition temperatures, corrosion resistance, and glass stability on heating which make them useful for technological applications. Yttrium aluminosilicate glass microspheres are currently being used for internal selective radiotherapy of liver cancer. During the preparation process, crystallization needs to be totally or partially avoided depending on the final application. Thus knowing the cry...

  19. Peripheral Blood Lymphocyte Depletion After Hepatic Arterial {sup 90}Yttrium Microsphere Therapy for Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Carr, Brian I., E-mail: brianicarr@hotmail.com [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA and Department of Nutrition and Exptl Biology, Saverio De Bellis Medical Research Institute, Castellana Grotte, Bari (Italy); Metes, Diana M. [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA and Department of Nutrition and Exptl Biology, Saverio De Bellis Medical Research Institute, Castellana Grotte, Bari (Italy)

    2012-03-01

    Purpose: The short- and long-term effects of {sup 90}Yttrium microspheres therapy for hepatocellular carcinoma (HCC) on peripheral blood lymphocytes are unknown and were therefore examined. Methods and Materials: Ninety-two HCC patients were enrolled in a {sup 90}Yttrium therapy study and routine blood counts were examined as part of standard clinical monitoring. Results: We found an early, profound, and prolonged lymphopenia. In a subsequent cohort of 25 additional HCC patients, prospective flow cytometric immune-monitoring analysis was performed to identify specific changes on distinct lymphocyte subsets (i.e., CD3, CD4, CD8 T, and CD19 B lymphocytes) and NK cells absolute numbers, in addition to the granulocytes and platelets subsets. We found that the pretreatment lymphocyte subset absolute numbers (with the exception of NK cells) had a tendency to be lower compared with healthy control values, but no significant differences were detected between groups. Posttherapy follow-up revealed that overall, all lymphocyte subsets, except for NK cells, were significantly (>50% from pretherapy values), promptly (as early as 24 h) and persistently (up to 30 months) depleted post-{sup 90}Yttrium microspheres therapy. In contrast, granulocytes increased rapidly (24 h) to compensate for lymphocyte depletion, and remained increased at 1-year after therapy. We further stratified patients into two groups, according to survival at 1 year. We found that lack of recovery of CD19, CD3, CD8, and especially CD4 T cells was linked to poor patient survival. No fungal or bacterial infections were noted during the 30-month follow-up period. Conclusions: The results show that lymphocytes (and not granulocytes, platelets, or NK cells) are sensitive to hepatic arterial {sup 90}Yttrium without associated clinical toxicity, and lack of lymphocyte recovery (possibly leading to dysregulation of adaptive cellular immunity) posttherapy indicates poor survival.

  20. Treatment of primary liver tumors with Yttrium-90 microspheres (TheraSphere) in high risk patients: analysis of survival and toxicities.

    Science.gov (United States)

    Reardon, Kelli A; McIntosh, Alyson F; Shilling, A Tanner; Hagspiel, Klaus D; Al-Osaimi, Abdullah; Berg, Carl; Caldwell, Stephen H; Northup, Patrick G; Angle, Fritz; Mulder, Robert; Rich, Tyvin A

    2009-02-01

    This retrospective study was undertaken to obtain information regarding the survival and toxicities after Yttrium-90 microspheres treatment in patients with primary liver malignancies. Baseline, treatment, and follow-up data were collected and analyzed for 21 patients treated with Yttrium-90 microspheres. Survival analysis was then performed. The results of this study showed that median survival for all the patients was 120 days. Twenty of 21 patients were categorized as high-risk with a median survival of 114 days. It was also found that one high-risk patient has survived 858 days with no recurrence of disease. Acute grade 3-5 toxicities were recorded for nine patients and consisted of elevations in AST and bilirubin, thrombocytopenia, abdominal pain, ascites, nausea, fatigue, and death. This study concluded that Yttrium-90 is a low-toxicity, outpatient alternative for individuals with liver cancer and without many options. The maximal value, however, may lie in the treatment of low-risk patients.

  1. Aspects of radiation protection during the treatment of liver cancer using yttrium-90 labelled microspheres

    International Nuclear Information System (INIS)

    Klemp, P.F.B.; Perry, A.M.; Fox, R.A.; Gray, B.N.; Burton, M.A.

    1989-01-01

    Twenty eight patients have received treatment for liver cancer by the intra-hepatic arterial injection of between 1 and 4 GBq of yttrium-90 labelled microspheres. The injection was performed at laparotomy. If 11.1 MBq of yttrium-90 are distributed evenly over 1 sq cm of tissue, the tissue surface will suffer an initial beta dose rate of 16.2 Gy h -1 . Special precautions are therefore essential during the injection procedure, subsequently in nursing the patient and if further intervention becomes necessary. A specially designed apparatus is used for the injection, glass spectacles are worn and if the active liver is to be handled, lead rubber gloves are used. The theatre is prepared so that contaminated items can be easily isolated and a 'spill pack' is readily available. At completion of the operation, the bremsstrahlung dose rate at 15 cm from the liver is initially 15 μSv h -1 GBq -1 . Contamination of urine is typically 20 to 50 kBq L -1 while the contamination of other body fluids is negligible. Finger doses to the surgeons has varied from 2 to 5 mSv GBq -1 injected while personnel film badges used to monitor the dose equivalent to the surgeons and ward staff have recorded maximum doses of 1.5 mSv and 300 μSv respectively. 11 refs., 1 fig., 3 tabs

  2. Temporary balloon occlusion of the common hepatic artery for administration of yttrium-90 resin microspheres in a patient with patent hepatoenteric collaterals.

    Science.gov (United States)

    Mahvash, Armeen; Zaer, Navid; Shaw, Colette; Chasen, Beth; Avritscher, Rony; Murthy, Ravi

    2012-02-01

    The most common serious complication of yttrium-90 ((90)Y) therapy is gastrointestinal ulceration caused by extrahepatic microsphere dispersion. The authors describe the use of a balloon catheter for temporary occlusion of the common hepatic artery to reverse hepatoenteric flow for lobar administration of resin microspheres when coil embolization of a retroportal artery was impossible. At 9 months after treatment, the patient had no gastrointestinal side effects and showed a partial response. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  3. Occupational exposure following Yttrium-90 microspheres SIR therapy

    International Nuclear Information System (INIS)

    Fontaine, P.; Boirie, G.; Dieudonne, A.; Leguludec, D.; Lebtahi, R.; Ben Reguiga, M.

    2015-01-01

    Full text of publication follows. Introduction: Selective Internal Radiation Therapy (SIRT) is a promising technique for solid hepatic neoplasms treatment. SIRT consists in implanting radioactive microspheres (RMS) in targeted hepatic lesions via femoral artery. Two RMS-Therapsheres [glass-microspheres/TSR] and Sir-Spheres [resin-spheres/SSR]- are marketed in the European market, both radiolabeled with Yttrium-90. The objective of this study is to assess occupational exposure for nuclear medicine, radiology and clinical staff involved in Y 90 -RMS preparation and implantation. Materials and methods: The study was conducted on 20 patients treated for Hepato-Cellular Carcinoma: 10 treated with TSR and 10 with SSR. Dose rate (DR, mSv/h) or absorbed doses (mSv) measurements were made during all steps of TSR and SSR handling: sources receipt and unpacking, preparation, transport to radiology, implantation, and patient care. Measurements were made with portable ionization chamber(Babyline/Nardeux), spectrometer(FieldSpect/Aries), digital dosimeter (NED/Unfors) and operational dosimeter (Mk2/Siemens). Values were expressed as mean±SD. Results: patients received of 1.8 GBq to 3.1 GBq of TSR and 0.55 GBq to 2.4 GBq of SSR. TSR were delivered ready-to-use with the prescribed activity. For SSR only one activity was commercially available and shipped (3 GBq at calibration-time)requiring a preparation step to adjust needed activity. DR measured during RMS was 1723 ± 157 μSv/h SSR and 1189 ± 92 μSv/h for TSR. When preparing spheres in radiopharmacy, fingers and whole body doses were respectively 8326 ± 2360 μSv and 12.3 ± 5,2 μSv for Sir-Spheres vs. 33.5 ± 7.8 μSv and 1.1 ± 0.3 μSv for TSR. DR in contact with carrying case during RMS transfer to radiology were 299 ± 102 μSv/h for SSR and 5.3 ± 1.2 μSv/h for TSR. During RMS infusion, radiologist's finger doses were limited to 3.6 ± 1 μSv for SSR and 0.7± 0.3 μSv for TSR. Finally, following RMS

  4. Treatment of diffuse large B-cell lymphoma of the liver with yttrium-90 microsphere embolization.

    Science.gov (United States)

    Fenske, Timothy S; Benjamin, Heather; Kroft, Steven H; Hohenwalter, Eric J; Rilling, William S

    2008-11-01

    A 41-year-old male with a 4-year history of chronic hepatitis C presented with a 1-month history of abdominal pain, fatigue, weight loss, and night sweats. Laboratory examinations, chest, abdomen, and pelvic CT scans, PET-CT scans, ultrasound-guided needle biopsies of liver lesions, bone-marrow biopsy, flow cytometry, and immunohistochemical staining for B-cell markers including CD20. Chemoresistant diffuse large B-cell lymphoma, with gradual loss of CD20 antigen expression. Embolization of hepatic tumors using yttrium-90 microspheres (Therasphere, Theragenics Corporation, Buford, GA).

  5. Pilot trial of Y-90 glass microspheres in the treatment of primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Houle, S.; Yip, T.C.K.; Shepherd, F.A.; Rotstein, L.E.; Theis, B.; Cawthorn, R.; Barnes, K.

    1987-01-01

    A pilot trial is currently under way at our institution to determine the potential of new Y-90 glass microspheres (Theraspheres, Theragenics Corp., Atlanta) for the treatment of primary hepatocellular carcinoma. The Y-90 microspheres are injected through a percutaneous hepatic artery catheter positioned angiographically. The injection is facilitated by a new delivery system. Prior to the injection of the Y-90 microspheres, the presence of shunting is assessed by injecting Tc-99m human albumin microspheres (HAM) via the hepatic artery catheter. Bremsstrahlung scans done after injection demonstrate the distribution the Y-90 microspheres within the liver and the lack of extrahepatic activity. In the first group of patients treated, no significant toxicity was demonstrated for absorbed doses between 5,000 and 10,000 rad to the liver, and up to 20,000 rad to the tumor itself

  6. Model-Based Radiation Dose Correction for Yttrium-90 Microsphere Treatment of Liver Tumors With Central Necrosis

    International Nuclear Information System (INIS)

    Liu, Ching-Sheng; Lin, Ko-Han; Lee, Rheun-Chuan; Tseng, Hsiou-Shan; Wang, Ling-Wei; Huang, Pin-I; Chao, Liung-Sheau; Chang, Cheng-Yen; Yen, Sang-Hue; Tung, Chuan-Jong; Wang, Syh-Jen; Oliver Wong, Ching-yee; Liu, Ren-Shyan

    2011-01-01

    Purpose: The objectives of this study were to model and calculate the absorbed fraction φ of energy emitted from yttrium-90 ( 90 Y) microsphere treatment of necrotic liver tumors. Methods and Materials: The tumor necrosis model was proposed for the calculation of φ over the spherical shell region. Two approaches, the semianalytic method and the probabilistic method, were adopted. In the former method, the range--energy relationship and the sampling of electron paths were applied to calculate the energy deposition within the target region, using the straight-ahead and continuous-slowing-down approximation (CSDA) method. In the latter method, the Monte Carlo PENELOPE code was used to verify results from the first method. Results: The fraction of energy, φ, absorbed from 90 Y by 1-cm thickness of tumor shell from microsphere distribution by CSDA with complete beta spectrum was 0.832 ± 0.001 and 0.833 ± 0.001 for smaller (r T = 5 cm) and larger (r T = 10 cm) tumors (where r is the radii of the tumor [T] and necrosis [N]). The fraction absorbed depended mainly on the thickness of the tumor necrosis configuration, rather than on tumor necrosis size. The maximal absorbed fraction φ that occurred in tumors without central necrosis for each size of tumor was different: 0.950 ± 0.000, and 0.975 ± 0.000 for smaller (r T = 5 cm) and larger (r T = 10 cm) tumors, respectively (p 90 Y microsphere treatment of hepatic tumors with central necrosis. With this model, important information is provided regarding the absorbed fraction applicable to clinical 90 Y microsphere treatment.

  7. Review: microspheres for radioembolization therapy

    International Nuclear Information System (INIS)

    Zhao Mingqiang; Xu Shuhe

    2007-12-01

    Radioembolization of liver cancer has been proven to be an effective therapy in nuclear medicine. The yttrium-90 glass microspheres has been used to treat both primary and metastatic liver tumors in clinic which shown encouraging results. The preparation, stability, degradation and application for medical purpose of radioactive microspheres are reviewed. At first, the theory of radioem- bolization treating cancer is discussed; and then three major radiolabled micro- sphere materials are expounded: viz. glass, resin-based and polymer-based; Future improvements in the preparation and use of radioactive microspheres are prospected at last. (authors)

  8. Review: microspheres for radioembolization therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mingqiang, Zhao; Shuhe, Xu [China Inst. of Atomic Energy, Beijing (China)

    2007-12-15

    Radioembolization of liver cancer has been proven to be an effective therapy in nuclear medicine. The yttrium-90 glass microspheres has been used to treat both primary and metastatic liver tumors in clinic which shown encouraging results. The preparation, stability, degradation and application for medical purpose of radioactive microspheres are reviewed. At first, the theory of radioem- bolization treating cancer is discussed; and then three major radiolabled micro- sphere materials are expounded: viz. glass, resin-based and polymer-based; Future improvements in the preparation and use of radioactive microspheres are prospected at last. (authors)

  9. Use of Yttrium-90 glass microspheres (TheraSphere) for the treatment of unresectable hepatocellular carcinoma in patients with portal vein thrombosis.

    Science.gov (United States)

    Salem, Riad; Lewandowski, Robert; Roberts, Carol; Goin, James; Thurston, Kenneth; Abouljoud, Marwan; Courtney, Angi

    2004-04-01

    Intra-arterial injection of Yttrium-90 glass microspheres ((90)Y- microS; TheraSphere, MDS Nordion, Ottawa, Canada) is indicated for treatment of unresectable hepatocellular carcinoma (HCC) in the presence of acceptable liver function. This study presents hepatic toxicity results after unilobar and bilobar intra-arterial administration of (90)Y- microS in patients with unresectable HCC who had known portal vein thrombosis (PVT) without evidence of cavernous transformation. Fifteen patients with unresectable HCC and PVT of one or both first order and related segmental portal venous branches received a total of 29 infusions of (90)Y- microS for treatment of HCC. All patients had pretreatment evaluation including: computed tomography (CT) imaging, alpha-fetoprotein (AFP) levels, liver function tests, technetium-99m macroaggregated albumin ((99)Tc-MAA) scan for evaluation of lung and visceral shunting, and angiography with visualization into the portal venous phase. (90)Y- micro S dose was based on lobar hepatic volume with adjustment for lung shunt activity. Liver toxicity was assessed by serum total bilirubin graded for severity according to the NIH NCI Clinical Toxicity Criteria (CTC version 2.0). Other adverse events were reported according to the standards established by the Society of Interventional Radiology. There were no procedural complications with delivery of (90)Y- microS, and treatment was well tolerated by all patients. Increased post-treatment bilirubin levels were observed across all treatments in five patients, four of whom had CT or AFP evidence of intrahepatic disease progression. After initial treatment, two patients developed bilirubin toxicity (grades 1 and 2); one patient demonstrated an increment in bilirubin toxicity grade (grade 1 to grade 3) and one patient had an improvement in grade after initial treatment. There were no new treatment-related toxicities in nine patients after a second treatment. (90)Y- microS treatment was well tolerated

  10. {sup 90}Y microspheres prepared by sol-gel method, promising medical material for radioembolization of liver malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Łada, Wiesława, E-mail: w.lada@ichtj.waw.pl [Institute of Nuclear Chemistry and Technology, 03-195 Warsaw, Dorodna 16 (Poland); Iller, Edward [National Centre for Nuclear Research, Radioisotope Centre POLATOM, 05-400 Otwock, Andrzej Sołtan 7 (Poland); Wawszczak, Danuta [Institute of Nuclear Chemistry and Technology, 03-195 Warsaw, Dorodna 16 (Poland); Konior, Marcin, E-mail: marcin.konior@polatom.pl [National Centre for Nuclear Research, Radioisotope Centre POLATOM, 05-400 Otwock, Andrzej Sołtan 7 (Poland); Dziel, Tomasz [National Centre for Nuclear Research, Radioisotope Centre POLATOM, 05-400 Otwock, Andrzej Sołtan 7 (Poland)

    2016-10-01

    A new technology for the production of radiopharmaceutical {sup 90}Y microspheres in the form of spherical yttrium oxide grains obtained by sol-gel method has been described. The authors present and discuss the results of investigations performed in the development of new production technology of yttrium microspheres and determination of their physic-chemical properties. The final product has the structure of spherical yttrium oxide grains with a diameter 25–100 μm, is stable and free from contaminants. Irradiation of 20 mg samples of grains with diameter of 20–50 μm in the thermal neutron flux of 1.7 × 10{sup 14} cm{sup −2} s{sup −1} at the core of MARIA research nuclear reactor allowed to obtain microspheres labelled with the {sup 90}Y isotope on the way of the nuclear reaction {sup 89}Y(n, γ){sup 90}Y. Specific activity of irradiated microspheres has been determined by application of absolute triple to double coincidence ratio method (TDCR) and has been evaluated at 190 MBq/mg Y. {sup 90}Y microspheres prepared by the proposed technique can be regarded as a promising medical material for radioembolization of liver malignancies. - Highlights: • Sol-gel methods for preparation of spherical yttrium trioxide grains have been proposed. • Determination condition for irradiation {sup 89}Y{sub 2}O{sub 3} grains in nuclear reactor • Evaluation of specific activity of {sup 90}Y microspheres • Estimation of {sup 90}Y microspheres as promising medical material for radioembolization.

  11. Root Cause Analysis of Gastroduodenal Ulceration After Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Marnix G. E. H. [Stanford University School of Medicine, Division of Interventional Radiology (United States); Banerjee, Subhas [Stanford University School of Medicine, Division of Gastroenterology and Hepatology (United States); Louie, John D.; Abdelmaksoud, Mohamed H. K. [Stanford University School of Medicine, Division of Interventional Radiology (United States); Iagaru, Andrei H. [Stanford University School of Medicine, Division of Nuclear Medicine and Molecular Imaging (United States); Ennen, Rebecca E.; Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-12-15

    IntroductionA root cause analysis was performed on the occurrence of gastroduodenal ulceration after hepatic radioembolization (RE). We aimed to identify the risk factors in the treated population and to determine the specific mechanism of nontarget RE in individual cases. Methods: The records of 247 consecutive patients treated with yttrium-90 RE for primary (n = 90) or metastatic (n = 157) liver cancer using either resin (n = 181) or glass (n = 66) microspheres were reviewed. All patients who developed a biopsy-proven microsphere-induced gastroduodenal ulcer were identified. Univariate and multivariate analyses were performed on baseline parameters and procedural data to determine possible risk factors in the total population. Individual cases were analyzed to ascertain the specific cause, including identification of the culprit vessel(s) leading to extrahepatic deposition of the microspheres. Results: Eight patients (3.2 %) developed a gastroduodenal ulcer. Stasis during injection was the strongest independent risk factor (p = 0.004), followed by distal origin of the gastroduodenal artery (p = 0.004), young age (p = 0.040), and proximal injection of the microspheres (p = 0.043). Prolonged administrations, pain during administration, whole liver treatment, and use of resin microspheres also showed interrelated trends in multivariate analysis. Retrospective review of intraprocedural and postprocedural imaging showed a probable or possible culprit vessel, each a tiny complex collateral vessel, in seven patients. Conclusion: Proximal administrations and those resulting in stasis of flow presented increased risk for gastroduodenal ulceration. Patients who had undergone bevacizumab therapy were at high risk for developing stasis.

  12. Root Cause Analysis of Gastroduodenal Ulceration After Yttrium-90 Radioembolization

    International Nuclear Information System (INIS)

    Lam, Marnix G. E. H.; Banerjee, Subhas; Louie, John D.; Abdelmaksoud, Mohamed H. K.; Iagaru, Andrei H.; Ennen, Rebecca E.; Sze, Daniel Y.

    2013-01-01

    IntroductionA root cause analysis was performed on the occurrence of gastroduodenal ulceration after hepatic radioembolization (RE). We aimed to identify the risk factors in the treated population and to determine the specific mechanism of nontarget RE in individual cases. Methods: The records of 247 consecutive patients treated with yttrium-90 RE for primary (n = 90) or metastatic (n = 157) liver cancer using either resin (n = 181) or glass (n = 66) microspheres were reviewed. All patients who developed a biopsy-proven microsphere-induced gastroduodenal ulcer were identified. Univariate and multivariate analyses were performed on baseline parameters and procedural data to determine possible risk factors in the total population. Individual cases were analyzed to ascertain the specific cause, including identification of the culprit vessel(s) leading to extrahepatic deposition of the microspheres. Results: Eight patients (3.2 %) developed a gastroduodenal ulcer. Stasis during injection was the strongest independent risk factor (p = 0.004), followed by distal origin of the gastroduodenal artery (p = 0.004), young age (p = 0.040), and proximal injection of the microspheres (p = 0.043). Prolonged administrations, pain during administration, whole liver treatment, and use of resin microspheres also showed interrelated trends in multivariate analysis. Retrospective review of intraprocedural and postprocedural imaging showed a probable or possible culprit vessel, each a tiny complex collateral vessel, in seven patients. Conclusion: Proximal administrations and those resulting in stasis of flow presented increased risk for gastroduodenal ulceration. Patients who had undergone bevacizumab therapy were at high risk for developing stasis

  13. Photoluminescence and lasing in whispering gallery mode glass microspherical resonators

    Energy Technology Data Exchange (ETDEWEB)

    Ristić, D. [Ruđer Bošković Institute, Division of Materials Physics, Laboratory for Molecular Physics, Bijenička c. 54, Zagreb (Croatia); Center of Excellence for Advanced Materials and Sensing Devices, Research unit New Functional Materials, Bijenička c. 54, Zagreb (Croatia); Berneschi, S.; Camerini, M. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Farnesi, D.; Pelli, S. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Centro Studi e Ricerche ' E. Fermi' , Piazza del Viminale 2, 00184 Roma (Italy); Trono, C. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Chiappini, A.; Chiasera, A.; Ferrari, M. [CSMFO Group, Istituto di Fotonica e Nanotecnologie, IFN-CNR, Via alla Cascata 56/C, 38050 Povo-Trento (Italy); Lukowiak, A. [Institute of Low Temperature and Structure Research, PAS, ul. Okolna 2, Wroclaw 50-950 (Poland); Dumeige, Y.; Féron, P. [Laboratoire d' Optronique, (CNRS-UMR 6082-Foton), ENSSAT, 6 rue de Kérampont, 22300 Lannion (France); Righini, G.C. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Centro Studi e Ricerche ' E. Fermi' , Piazza del Viminale 2, 00184 Roma (Italy); Soria, S., E-mail: s.soria@ifac.cnr.it [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Conti, G. Nunzi [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Centro Studi e Ricerche ' E. Fermi' , Piazza del Viminale 2, 00184 Roma (Italy)

    2016-02-15

    We report experimental results regarding the development of Er{sup 3+}-doped glass microspherical cavities for the fabrication of compact sources at 1.55 μm. We investigate several different approaches in order to fabricate the microspheres including direct melting of Er{sup 3+}-doped glass powders, synthesis of Er{sup 3+}-doped monolithic microspheres by drawing Er{sup 3+}-doped glass, and coating of silica microspheres with an Er{sup 3+}-doped sol–gel layer. Details of the different fabrication processes are presented together with the photoluminescence characterization in free space configuration of the microspheres and of the glass precursor. We have analyzed the photoluminescence spectra of the whispering gallery modes of the microspheres excited using evanescent coupling and we demonstrate tunable laser action in a wide range of wavelengths around 1.55 μm. As much as 90 μW of laser output power was measured in Er{sup 3+}-doped glass microspheres. - Highlights: • Different approaches in microsphere fabrication and various types of post-processing. • Trimming of photorefractive glass microsphere lasers with UV light. • Peak power record of 90 μW by pumping at 1480 nm.

  14. Sustained safety and efficacy of extended-shelf-life {sup 90}Y glass microspheres: long-term follow-up in a 134-patient cohort

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowski, Robert J.; Minocha, Jeet; Memon, Khairuddin; Riaz, Ahsun; Gates, Vanessa L.; Ryu, Robert K.; Sato, Kent T.; Omary, Reed; Salem, Riad [Northwestern University, Department of Radiology, Chicago, IL (United States)

    2014-03-15

    To validate our initial pilot study and confirm sustained safety and tumor response of extended-shelf-life {sup 90}Y glass microspheres. We hypothesized that for the same planned tissue dose, the increase in number of glass microspheres (decayed to the second week of their allowable shelf-life) administered for the same absorbed dose would result in better tumor distribution of the microspheres without causing additional adverse events. Between June 2007 and January 2010, 134 patients underwent radioembolization with extended-shelf-life {sup 90}Y glass microspheres; data from 84 new patients were combined with data from our 50-patient pilot study cohort. Baseline and follow-up imaging and laboratory data were obtained 1 and 3 months after therapy and every 3 months thereafter. Clinical and biochemical toxicities were prospectively captured and categorized according to the Common Terminology Criteria. Response in the index lesion was assessed using WHO and EASL guidelines. The mean delivered radiation dose was 123 Gy to the target liver tissue. The mean increase in number of microspheres with this approach compared to standard {sup 90}Y glass microsphere dosimetry was 103 %, corresponding to an increase from 3.84 to 7.78 million microspheres. Clinical toxicities included fatigue (89 patients, 66 %), abdominal pain (49 patients, 36.6 %), and nausea/vomiting (25 patients, 18.7 %). Grade 3/4 bilirubin toxicity was seen in three patients (2 %). Two (1 %) of the initial 50-patient cohort showed gastroduodenal ulcers; gastroduodenal ulcers were not seen in any of the subsequent 84 patients. According to WHO and EASL guidelines, response rates were 48 % and 57 %, respectively, and 21 % demonstrated a complete EASL response. This study showed sustained safety and efficacy of extended-shelf-life {sup 90}Y glass microspheres in a larger, 134-patient cohort. The increase in number of microspheres administered theoretically resulted in better tumor distribution of the

  15. Yttrium-90 microspheres for the treatment of hepatocellular carcinoma: A review

    International Nuclear Information System (INIS)

    Salem, Riad; Hunter, Russell D.

    2006-01-01

    To present a critical review of yttrium-90 (TheraSphere) for the treatment of hepatocellular carcinoma (HCC). Medical literature databases (Medline, Cochrane Library, and CANCERLIT) were searched for available literature concerning the treatment of HCC with TheraSphere. These publications were reviewed for scientific and clinical validity. Studies pertaining to the use of yttrium-90 for HCC date back to the 1960s. The results from the early animal safety studies established a radiation exposure range of 50-100 Gy to be used in human studies. Phase I dose escalation studies followed, which were instrumental in delineating radiation dosimetry and safety parameters in humans. These early studies emphasized the importance of differential arteriolar density between hypervascular HCC and surrounding liver parenchyma. Current trends in research have focused on advancing techniques to safely implement this technology as an alternative to traditional methods of treating unresectable HCC, such as external beam radiotherapy, conformal beam radiotherapy, ethanol ablation, trans-arterial chemoembolization, and radiofrequency ablation. Yttrium-90 (TheraSphere) is an outpatient treatment option for HCC. Current and future research should focus on implementing multicenter phase II and III trials comparing TheraSphere with other therapies for HCC

  16. Yttrium-90 microspheres for the treatment of hepatocellular carcinoma: a review.

    Science.gov (United States)

    Salem, Riad; Hunter, Russell D

    2006-01-01

    To present a critical review of yttrium-90 (TheraSphere) for the treatment of hepatocellular carcinoma (HCC). Medical literature databases (Medline, Cochrane Library, and CANCERLIT) were searched for available literature concerning the treatment of HCC with TheraSphere. These publications were reviewed for scientific and clinical validity. Studies pertaining to the use of yttrium-90 for HCC date back to the 1960s. The results from the early animal safety studies established a radiation exposure range of 50-100 Gy to be used in human studies. Phase I dose escalation studies followed, which were instrumental in delineating radiation dosimetry and safety parameters in humans. These early studies emphasized the importance of differential arteriolar density between hypervascular HCC and surrounding liver parenchyma. Current trends in research have focused on advancing techniques to safely implement this technology as an alternative to traditional methods of treating unresectable HCC, such as external beam radiotherapy, conformal beam radiotherapy, ethanol ablation, trans-arterial chemoembolization, and radiofrequency ablation. Yttrium-90 (TheraSphere) is an outpatient treatment option for HCC. Current and future research should focus on implementing multicenter phase II and III trials comparing TheraSphere with other therapies for HCC.

  17. Right Gastric Artery Embolization Prior to Treatment with Yttrium-90 Microspheres

    International Nuclear Information System (INIS)

    Cosin, Octavio; Bilbao, Jose Ignacio; Alvarez, Sergio; Luis, Esther de; Alonso, Alberto; Martinez-Cuesta, Antonio

    2007-01-01

    Purpose. Intra-arterial infusion of yttrium-90 microspheres is a form of radiation treatment for unresectable hepatic neoplasms. Misdeposition of particles in the gastroduodenal area such as the right gastric artery (RGA) may occur with serious consequences. We present a series of patients who underwent a detailed vascular study followed by RGA embolization. Special emphasis is placed on anatomic variations and technical considerations .Methods. In a 1 year period, 27 patients were treated. Initial vascular evaluation was performed, with careful attention to anatomic variants or extrahepatic arterial supply, especially to the gastroduodenal area. Embolization of such arteries was planned if needed. RGA embolization was performed antegradely from the hepatic artery or retrogradely via the left gastric artery (LGA). Postprocedural follow-up included clinical interview and gastroscopy if necessary. Results. RGA embolization was performed in 9 patients presenting with primary (n = 3) or metastatic liver tumors (n 6). Six patients underwent antegrade RGA embolization and 3 had embolization done retrogradely via the LGA. Retrograde access was chosen for anatomic reasons. None of the patients complained of gastroduodenal symptoms. Conclusion. RGA embolization can help minimize the gastroduodenal deposition of radioactive particles. RGA embolization should routinely be carried out. The procedure can be performed, with similar technical success, by both anterograde and retrograde approaches

  18. Hepatobiliary effects of 90yttrium microsphere therapy for unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Nalesnik, Michael A; Federle, Michael; Buck, David; Fontes, Paulo; Carr, Brian I

    2009-01-01

    (90)Yttrium (Therasphere) microspheres administered via hepatic artery are a valuable option for treatment of hepatocellular carcinoma. This therapy targets tumor nodules while largely sparing hepatic parenchyma. This retrospective study examines liver explants from 13 adult patients with hepatocellular carcinoma who received intrahepatic Theraspheres and subsequently underwent liver transplantation. Histopathologic and laboratory reviews are performed. Theraspheres preferentially migrated to the lobe(s) supplied by the injected artery branches and frequently localized to tumors. Tumors showed a chronology of changes beginning with confluent necrosis typically accompanied by hemorrhage and later by fibrinoid change. This was followed by fibrosis with regenerative activity at tumor peripheries. Adjacent hepatic parenchyma went through a similar sequence of injury and repair that could lead to markedly fibrotic cirrhotic nodules in the vicinity of treated tumors. No consistent pattern of thrombomodulin loss was seen in endothelial cells of the tumors or adjacent parenchyma, suggesting that direct endothelial cell injury was likely not a major contributor to the necrotic process. However, the pattern of injury and repair is suggestive of a localized and subclinical form of radiation-induced liver disease. The pathologist should be aware of these changes to distinguish them from the diffuse "radiation hepatitis" associated with older forms of radiotherapy.

  19. Quantitative and Qualitative Assessment of Yttrium-90 PET/CT Imaging

    OpenAIRE

    Attarwala, Ali Asgar; Molina-Duran, Flavia; Büsing, Karen-Anett; Schönberg, Stefan O.; Bailey, Dale L.; Willowson, Kathy; Glatting, Gerhard

    2014-01-01

    Yttrium-90 is known to have a low positron emission decay of 32 ppm that may allow for personalized dosimetry of liver cancer therapy with (90)Y labeled microspheres. The aim of this work was to image and quantify (90)Y so that accurate predictions of the absorbed dose can be made. The measurements were performed within the QUEST study (University of Sydney, and Sirtex Medical, Australia). A NEMA IEC body phantom containing 6 fillable spheres (10-37 mm ∅) was used to measure the 90Y distribut...

  20. Hepatic arterial 90Yttrium glass microspheres (Therasphere) for unresectable hepatocellular carcinoma: interim safety and survival data on 65 patients.

    Science.gov (United States)

    Carr, Brian I

    2004-02-01

    Hepatocellular carcinoma (HCC) generally arises in a cirrhotic liver and, in most cases, is multifocal and bilobar. Although trans-hepatic artery chemoembolization (TACE) can be highly affective in shrinking tumors, it is limited by virtue of the damage that it can cause to the liver that is already damaged by chronic disease. A high priority in HCC research, after primary prevention and early detection, is to find new treatment modalities that are both effective and non-toxic to the underlying cirrhotic liver. A cohort of 65 patients with biopsy-proven unresectable HCC have been treated with hepatic arterial 90Yttrium microspheres (Therasphere), and the interim results are reported here. Only 1 cycle of Therasphere treatment ever was performed on 46 patients, 17 patients had 2 cycles, and 2 patients had 3 cycles of therapy. The median dose delivered was 134 Gy, typically as either 5 or 10 GBq (2-4 million microspheres). Clinical toxicities include 9 episodes of abdominal pain and 2 episodes of acute cholecystitis, requiring cholecystectomy. A main lab toxicity was elevated bilirubin which increased by more than 200% in 25 patients (30.5%) during 6 months of therapy, although 18 of these patients had only transient elevation. A prominent finding was prolonged and profound (>70%) lymphopenia in more than 75% of the patients, but without clinical significance. Forty-two patients (64.6%) had a substantial decrease in tumor vascularity in response to therapy, and 25 patients (38.4%) had a partial response, by computed tomography scan. Median survival for Okuda stage I patients (n=42) was 649 days (historical comparison 244) and for Okuda stage II patients (n=23) was 302 days (historical comparison 64 days). All patients were followed after therapy for a minimum of 6 months. There were 42 deaths, 21 due to liver failure, 6 from HCC progression, and 3 from metastases. Therasphere appears to be a relatively safe and effective therapy for advanced-stage unresectable HCC.

  1. Comparison of post-embolization syndrome in the treatment of patients with unresectable hepatocellular carcinoma: Trans-catheter arterial chemo-embolization versus Yttrium-90 glass microspheres

    International Nuclear Information System (INIS)

    Goin, J.E.; Roberts, C.A.; Dancey, J.E.; Sickles, C.J.; Leung, D.A.; Soulen, M.C.

    2004-01-01

    Post-embolization syndrome (PES) occurs in most patients who undergo trans-catheter arterial chemoembolization (TACE) for treatment of unresectable hepatocellular carcinoma (HCC). Intra-hepatic arterial administration of TheraSphere, yttrium-90 glass microspheres, is an alternative treatment for unresectable HCC that does not require embolization of major vessels and may have a more favorable toxicity profile than TACE. This paper compares the incidence of PES after TACE vs. TheraSphere treatment in unresectable HCC patients. Data for 29 TACE-treated and 34 TheraSphere-treated patients were evaluated for PES. PES toxicities (i.e., nausea, vomiting, fever in the absence of infection, and abdominal pain) were scored according to Southwest Oncology Group (SWOG) toxicity criteria. PES was defined as a total score for the four toxicities of 2 or greater. Survival was defined from the date of treatment to the date of death. TACE patients underwent one to seven treatment procedures; TheraSphere patients underwent one to two treatment procedures. The incidence of PES was 3.8-times (95% confidence interval 1.6-16.3) higher after TACE [20/29(69%)] than after TheraSphere [6/34 (18%)] treatment; this difference was statistically significant (p=.003). Median survival was similar for TheraSphere (N=20; 378 days, CI 209-719) and TACE (N=29; 343 days, CI 217-511) patients. It was concluded that treatment of unresectable HCC with TheraSphere results in a much lower incidence of PES compared to TACE. Since TheraSphere is a pure beta emitter; it can potentially be administered safely on an outpatient basis, and appears to be at least as efficacious as TACE on survival with fewer treatments per patient. (author)

  2. Patent hepatic falciform artery detected after Tc-99m-macroaggregated albumin injection on SPECT/CT prior to Yttrium-90 microsphere radioembolization: a case report

    International Nuclear Information System (INIS)

    Karaman, B.; Aslan, A.; Hamcan, S.; Ugurel, M.

    2012-01-01

    Full text: Introduction: Yttrium-90 (Y-90) microsphere radioembolization is increasingly used for the treatment of unresectable hepatocellular carcinoma and liver metastasis. Objectives and tasks: We aim to present the upper abdominal wall skin involvement detected during routine pre-therapy Technetium-99m-macroaggregated albumin (Tc-99m-MAA) on SPECT/CT due to patent hepatic falciform artery and the precautions to avoid this potential complication. Material and methods: 38-year-old male with colon cancer and multiple liver metastasis was evaluated prior to radioembolization and Tc-99 MAA was slowly hand injected at the bifurcation of the proper hepatic artery. Then, the SPECT/CT scan was performed in order to investigate the systemic shunt or gastric involvement. Results: On SPECT/CT scan, involvement of the upper abdominal wall through falciform ligament was seen. Re-evaluation of the hepatic angiogram identified a patent hepatic falciform artery arising from the left hepatic artery. Y-90 microspheres were slowly hand injected to the left hepatic artery superselectively and no extra-hepatic activity was seen on SPECT/CT scan. Conclusion: Upper abdominal pain and dermatitis are uncommon findings after radioembolization and may occur due to inadvertent delivery of Y-90 microspheres into patent hepatic falciform artery. To prevent these complications, either patent hepatic falciform artery must be embolized by coil or Y-90 injection must be performed superselectively

  3. Radiolabeling Of Albumin Particles With Yttrium-90

    International Nuclear Information System (INIS)

    Nguyen Thi Thu; Nguyen Thi Khanh Giang; Bui Van Cuong, Vo Thi Cam Hoa

    2011-01-01

    This paper presents the process of the radiolabeling of microaggregated albumin particles with radionuclide Yttrium-90 using the directed method. The albumin microsphere kit was prepared in sodium phosphate buffer. The original solution includes 2 mg albumin particle and 0.5 mg stannous chloride dihydrate. The albumin particles size was ranged from 5 ?m to 30 ?m. The mixture was washed three times with phosphate buffer saline, pH 7.2 by centrifugation and suspended in 0.5 M sodium acetate buffer, pH 6. Yttrium - 90 in 1.0 M acetic acid was collected from 90 Sr/ 90 Y generator. The labeling of the particles with Y-90 (185 MBq) was performed at pH 5.5 in acetate buffer with agitating for 60 min at room temperature. The labeled albumin suspensions were centrifuged at 3000 rpm for 15 min. Labeling yields was calculated using centrifugation, filtration and compared with paper chromatography, which is developed in the Tris Acetic EDTA. In this system, the unbound of Y-90 migrates to an R f of 0.9-1.0 and the radiolabeled albumin particles remains at the point of origin (R f = 0). The size of 90 Y-albumin particles was compared with the albumin particles in the original solution to be sure that they did not change during the labeling treatment. The radiolabeling yields were more than 80%. The labeled compound was dialysis in phosphate buffer. The radiochemical purity was 98%. The 90 Y- albumin is an ideal radiopharmaceutical for potential use in malignant cancer treatment as brachytherapy. (author)

  4. A Comparative Study of Production of Glass Microspheres by using Thermal Process

    Science.gov (United States)

    Lee, May Yan; Tan, Jully; Heng, Jerry YY; Cheeseman, Christopher

    2017-06-01

    Microspheres are spherical particles that can be distinguished into two categories; solid or hollow. Microspheres typical ranges from 1 to 200 μm in diameter. Microsphere are made from glass, ceramic, carbon or plastic depending on applications. Solid glass microsphere is manufactured by direct burning of glass powders while hollow glass microspheres is produced by adding blowing agent to glass powder. This paper presented the production of glass microspheres by using the vertical thermal flame (VTF) process. Pre-treated soda lime glass powder with particle sized range from 90 to 125μm was used in this work. The results showed that glass microspheres produced by two passes through the flame have a more spherical shape as compared with the single pass. Under the Scanning Electron Microscope (SEM), it is observed that there is a morphology changed from uneven surface of glass powders to smooth spherical surface particles. Qualitative analysis for density of the pre-burned and burned particles was performed. Burned particles floats in water while pre-burned particles sank indicated the change of density of the particles. Further improvements of the VTF process in terms of the VTF set-up are required to increase the transformation of glass powders to glass microspheres.

  5. Resin 90Y microsphere activity measurements for liver brachytherapy

    International Nuclear Information System (INIS)

    Dezarn, William A.; Kennedy, Andrew S.

    2007-01-01

    The measurement of the radioactivity administered to the patient is one of the major components of 90 Y microsphere liver brachytherapy. The activity of 90 Y microspheres in a glass delivery vial was measured in a dose calibrator. The calibration value to use for 90 Y in the dose calibrator was verified using an activity calibration standard provided by the microsphere manufacturer. This method allowed for the determination of a consistent, reproducible local activity standard. Additional measurements were made to determine some of the factors that could affect activity measurement. The axial response of the dose calibrator was determined by the ratio of activity measurements at the bottom and center of the dose calibrator. The axial response was 0.964 for a glass shipping vial, 1.001 for a glass V-vial, and 0.988 for a polycarbonate V-vial. Comparisons between activity measurements in the dose calibrator and those using a radiation survey meter were found to agree within 10%. It was determined that the dose calibrator method was superior to the survey meter method because the former allowed better defined measurement geometry and traceability of the activity standard back to the manufacturer. Part of the preparation of resin 90 Y microspheres for patient delivery is to draw out a predetermined activity from a shipping vial and place it into a V-vial for delivery to the patient. If the drawn activity was placed in a glass V-vial, the activity measured in the dose calibrator with a glass V-vial was 4% higher than the drawn activity from the shipping vial standard. If the drawn activity was placed in a polycarbonate V-vial, the activity measured in the dose calibrator with a polycarbonate V-vial activity was 20% higher than the drawn activity from the shipping vial standard. Careful characterization of the local activity measurement standard is recommended instead of simply accepting the calibration value of the dose calibrator manufacturer

  6. Occupational radiation exposure of medical staff performing 90Y-loaded microsphere radioembolization

    International Nuclear Information System (INIS)

    Laffont, Sophie; Ardisson, Valerie; Lenoir, Laurence; Rolland, Yan; Rohou, Tanguy; Edeline, Julien; Pracht, Marc; Sourd, Samuel Le; Lepareur, Nicolas; Garin, Etienne

    2016-01-01

    Radioembolization of liver cancer with 90 Y-loaded microspheres is increasingly used but data regarding hospital staff exposure are scarce. We evaluated the radiation exposure of medical staff while preparing and injecting 90 Y-loaded glass and resin microspheres especially in view of the increasing use of these products. Exposure of the chest and finger of the radiopharmacist, nuclear medicine physician and interventional radiologist during preparation and injection of 78 glass microsphere preparations and 16 resin microsphere preparations was monitored. Electronic dosimeters were used to measure chest exposure and ring dosimeters were used to measure finger exposure. Chest exposure was very low for both products used (<10 μSv from preparation and injection). In our experience, finger exposure was significantly lower than the annual limit of 500 mSv for both products. With glass microspheres, the mean finger exposure was 13.7 ± 5.2 μSv/GBq for the radiopharmacist, and initially 17.9 ± 5.4 μSv/GBq for the nuclear medicine physician reducing to 13.97 ± 7.9 μSv/GBq with increasing experience. With resin microspheres, finger exposure was more significant: mean finger exposure for the radiopharmacist was 295.1 ± 271.9 μSv/GBq but with a reduction with increasing experience to 97.5 ± 35.2 μSv/GBq for the six most recent dose preparations. For administration of resin microspheres, the greatest mean finger exposure for the nuclear medicine physician (the most exposed operator) was 235.5 ± 156 μSv/GBq. Medical staff performing 90 Y-loaded microsphere radioembolization procedures are exposed to safe levels of radiation. Exposure is lower than that from treatments using 131 I-lipiodol. The lowest finger exposure is from glass microspheres. With resin microspheres finger exposure is acceptable but could be optimized in accordance with the ALARA principle, and especially in view of the increasing use of radioembolization. (orig.)

  7. Dose-response evaluation after Yttrium-90 resin microsphere radio-embolization of breast cancer liver metastases

    International Nuclear Information System (INIS)

    Gnesin, S.; Verdun, F.R.; Baechler, S.; Boubacker, A.; Adib, S.; Cherbuin, N.; Prior, J.O.; Bize, P.; Denys, A.

    2015-01-01

    Full text of publication follows. Aim: Yttrium-90 resin microsphere radio-embolization is a valuable therapeutic option in metastatic breast cancer patients with progressive disease refractory to chemotherapy. The goal of this study was to evaluate the dose-response relationship of liver metastasis based on a 3D voxelized 90 Y PET dosimetry. Materials and methods: we studied the dose-response relationship of twelve hepatic lesions in four selected patients with metastatic breast cancer who underwent 90 Y radio-embolization (Sirtex SIR-Spheres Pty Ltd.). The administered activity ranged from 1 to 1.3 GBq. Ten days before treatment, patients underwent a baseline 18 F-FDG PET/CT. The determination of the 90 Y-microsphere activity to administer for treatment was based on the BSA method refined with the partition model derived from a 99m Tc-MAA SPECT/CT performed a week prior to radio-embolization. Within 24 hours after treatment, 90 Y TOF PET/CT imaging was performed. A follow-up 18 F-FDG PET/CT was performed 1 month after the treatment to evaluate the response to radio-embolization. For each patient, 3D voxelized dose-maps were obtained from the post-treatment 90 Y TOF PET/CT. A volume of interest (VOI) was drawn for each selected hepatic lesion using the baseline 18 F-FDG PET/CT. To obtain dose-volume histogram (DVH) for each lesion, image co-registration and VOI masks were generated using the PMOD 3.4 software and then exported in Matlab for dose calculation. Furthermore, the average absorbed dose in lesions was corrected for PVE effects by multiplication for appropriate (phantom-based) recovery coefficients according to the lesion size. Early metabolic lesion response was assessed in terms of variation in the maximum standard uptake value (ΔSUVmax) between baseline and follow-up 18 F-FDG PET/CT. The average absorbed dose for each lesion was associated with the respective metabolic response. Results: for the 12 selected lesions, the average volume was 35 cm 3

  8. Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer

    International Nuclear Information System (INIS)

    Ho, S.; Lau, W.Y.; Leung, T.W.T.; Chan, M.; Johnson, P.J.; Li, A.K.C.

    1997-01-01

    Radiation doses to the tumour and non-tumorous liver compartments from yttrium-90 microspheres in the treatment of hepatic cancer, as estimated by a partition model, have been verified by correlation with the actual doses measured with a beta probe at open surgery. The validity of the doses to the lungs, the tumour and non-tumours liver compartment as estimated by the partition model was further evaluated in clinical settings. On the basis of the observation that one of three patients who received more than 30 Gy from a single treatment and one of two patients who received more than 50 Gy from multiple treatments developed radiation pneumonitis, it was deduced that an estimated lung dose 30 Gy as estimated by the partition model and were predicted to develop radiation pneumonitis, did so despite the use of partial hepatic embolization to reduce the degree of lung shunting. Furthermore, a higher radiological response rate and prolonged survival were found in the group of patients who received higher tumour doses, as estimated by the partition model, than in the group with lower estimated tumour doses. Thus the radiation doses estimated by the partition model can be used to predict (a) complication rate, (b) response rate and (c) duration of survival in the same manner as the actual radiation doses measured with a beta probe at open surgery. The partition model has made selective internal radiation therapy using 90 Y microspheres safe and repeatable without laparotomy. (orig.)

  9. Recommendations for radioembolisation after liver surgery using yttrium-90 resin microspheres based on a survey of an international expert panel

    International Nuclear Information System (INIS)

    Samim, Morsal; Veenendaal, Linde M. van; Braat, Manon N.G.J.A.; Hoven, Andor F. van den; Bosch, Maurice A.A.J. van den; Lam, Marnix G.E.H.; Hillegersberg, Richard van; Sangro, Bruno; Kao, Yung Hsiang; Liu, Dave; Louie, John D.; Sze, Daniel Y.; Rose, Steven C.; Brown, Daniel B.; Ahmadzadehfar, Hojjat; Kim, Edward

    2017-01-01

    Guidelines on how to adjust activity in patients with a history of liver surgery who are undergoing yttrium-90 radioembolisation ( 90 Y-RE) are lacking. The aim was to study the variability in activity prescription in these patients, between centres with extensive experience using resin microspheres 90 Y-RE, and to draw recommendations on activity prescription based on an expert consensus. The variability in activity prescription between centres was investigated by a survey of international experts in the field of 90 Y-RE. Six representative post-surgical patients (i.e. comparable activity prescription, different outcome) were selected. Information on patients' disease characteristics and data needed for activity calculation was presented to the expert panel. Reported was the used method for activity prescription and whether, how and why activity reduction was found indicated. Ten experts took part in the survey. Recommendations on activity reduction were highly variable between the expert panel. The median intra-patient range was 44 Gy (range 18-55 Gy). Reductions in prescribed activity were recommended in 68% of the cases. In consensus, a maximum D Target of 50 Gy was recommended. With a current lack of guidelines, large variability in activity prescription in post-surgical patients undergoing 90 Y-RE exists. In consensus, D Target ≤50 Gy is recommended. (orig.)

  10. Glass microspheres for brachytherapy

    International Nuclear Information System (INIS)

    Prado, Miguel O.; Prastalo, Simon; Blaumann, Herman; Longhino, Juan M.; Repetto Llamazares, A.H.V.

    2007-01-01

    We developed the capacity to produce glass microspheres containing in their structure one or more radioactive isotopes useful for brachytherapy. We studied the various facts related with their production: (Rare earth) alumino silicate glass making, glass characterization, microspheres production, nuclear activation through (n,γ) nuclear reactions, mechanical characterization before and after irradiation. Corrosion tests in simulated human plasma and mechanical properties characterization were done before and after irradiation. (author) [es

  11. Treatment of hepatocellular carcinoma (HCC) with intra-arterial Yttrium-90 microspheres for down-staging patients to transplantation

    International Nuclear Information System (INIS)

    De Man, K.; Defreyne, L.; Delanghe, E.; Smeets, P.; Verhelst, X.; Geerts, A.; Van Vlierberghe, H.; Rogiers, X.; Troisi, R.; Lambert, B.

    2015-01-01

    Full text of publication follows. Introduction and aim: in our hospital, patients are referred for intra-arterial treatment with Yttrium-90 microspheres if they present with an HCC confined to the liver, but are ineligible for curative treatment options such as liver transplantation, partial hepatectomy or radio-frequent ablation. Additional eligibility criteria for radio-embolisation consist of Child-P ugh score Yttrium-90 microspheres in our hospital since 2008 and who presented at an age <70 and with a disease load exceeding the Milan criteria (single tumour ≤5 cm or ≤ 3 lesions ≤ 3 cm). We recorded whether the patient was down staged to a tumour load complying with the Milan criteria, and if so, whether transplantation was carried out. Results: 40 patients aged <70 years and with a tumour load exceeding the Milan criteria (all treated with TheraSphere, Nordion except 1 with SIR-Spheres, Sirtex) were evaluable. 35 had Barcelona Clinic Liver Cancer (BCLC) B stage disease and 5 had BCLC C. Overall median survival was 12.9 months. 16 out of 40 patients were down staged to the Milan criteria (40%, all BCLC B), of whom 8 were actually transplanted so far. Two patients are on the waiting list, 1 patient refuses to be listed and 1 patient suffers co-morbidity that excludes him from abdominal surgery. Unfortunately 4 patients died before or during work-out for transplantation: 1 unexplained sudden death, 1 lung embolism and 2 due to liver failure. The overall median survival was 30,4 months in the down staged patients. 24 out 40 patients (60%) did not have a tumour load within the Milan criteria at any point of their follow up and had a significant worse

  12. Recommendations for radioembolisation after liver surgery using yttrium-90 resin microspheres based on a survey of an international expert panel

    Energy Technology Data Exchange (ETDEWEB)

    Samim, Morsal [University Medical Center Utrecht, Department of Surgery, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Veenendaal, Linde M. van; Braat, Manon N.G.J.A.; Hoven, Andor F. van den; Bosch, Maurice A.A.J. van den; Lam, Marnix G.E.H. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Hillegersberg, Richard van [University Medical Center Utrecht, Department of Surgery, Utrecht (Netherlands); Sangro, Bruno [Clinica Universidad de Navarra-IDISNA and CIBEREHD, Liver Unit, Pamplona (Spain); Kao, Yung Hsiang [Cabrini Hospital, Department of Nuclear Medicine, Melbourne (Australia); Liu, Dave [Vancouver General Hospital, University of British Columbia, Department of Radiology, Vancouver, British Columbia (Canada); Louie, John D.; Sze, Daniel Y. [Stanford University Medical Center, Division of Interventional Radiology, Stanford (United States); Rose, Steven C. [University of California, Department of Radiology, San Diego (United States); Brown, Daniel B. [Vanderbilt University, Medical Center North, Department of Radiology, Nashville (United States); Ahmadzadehfar, Hojjat [University Hospital Bonn, Department of Nuclear Medicine, Bonn (Germany); Kim, Edward [Icahn School of Medicine at Mount Sinai, Division of Vascular and Interventional Radiology, New York (United States)

    2017-12-15

    Guidelines on how to adjust activity in patients with a history of liver surgery who are undergoing yttrium-90 radioembolisation ({sup 90}Y-RE) are lacking. The aim was to study the variability in activity prescription in these patients, between centres with extensive experience using resin microspheres {sup 90}Y-RE, and to draw recommendations on activity prescription based on an expert consensus. The variability in activity prescription between centres was investigated by a survey of international experts in the field of {sup 90}Y-RE. Six representative post-surgical patients (i.e. comparable activity prescription, different outcome) were selected. Information on patients' disease characteristics and data needed for activity calculation was presented to the expert panel. Reported was the used method for activity prescription and whether, how and why activity reduction was found indicated. Ten experts took part in the survey. Recommendations on activity reduction were highly variable between the expert panel. The median intra-patient range was 44 Gy (range 18-55 Gy). Reductions in prescribed activity were recommended in 68% of the cases. In consensus, a maximum D{sub Target} of 50 Gy was recommended. With a current lack of guidelines, large variability in activity prescription in post-surgical patients undergoing {sup 90}Y-RE exists. In consensus, D{sub Target} ≤50 Gy is recommended. (orig.)

  13. Yttrium-90 radioembolization using TheraSphere in the management of primary and secondary liver tumors.

    Science.gov (United States)

    Riaz, A; Lewandowski, R J; Kulik, L; Salem, R

    2009-06-01

    Locoregional therapies, such as transarterial chemoembolization, radioembolization and thermal ablation (e.g., radiofrequency ablation) are establishing their roles in the management of liver malignancies. With yYttrium-90 radioembolization therapy (90Y) radionuclide labeled microspheres are injected into the tumor feeding artery. This allows the delivery of a high radioactive dose to the tumor with minimal toxicity to normal tissues. 90Y has demonstrated to be safe and effective in the management of liver tumors. Authors present a review of the literature available for the use of TheraSphere for radioembolization in the management of liver tumors.

  14. Development and evaluation of holmium doped phosphate glass microspheres for selective internal radiotherapy

    International Nuclear Information System (INIS)

    Barros Filho, Eraldo C.; Martinelli, Jose Roberto; Squair, Peterson L; Osso Junior, Joao A.; Sene, Frank Ferrer

    2013-01-01

    Selective Internal Radiotherapy is used to treat hepatocellular carcinoma. In this treatment 90 Y -doped aluminosilicate glass microspheres are introduced in the hepatic artery and they migrate to the liver near to the tumor where they are trapped in the arterioles. The radiation β- emitted by the decay of 90 Y annihilates the cancer cells. A macroaggregate of albumin containing technetium is previously used to monitor the lung shunt and to prevent the spreading of 90 Y during the treatment. In the present work, 165 Ho- doped phosphate glass microspheres were developed aiming that application. 165 Ho has high cross section for neutron capture (64 bars) and 166 Ho decays emitting β- radiation with appropriate energy for killing cancer cells, and gamma rays with low energy which can be used to obtain images of the microspheres location and to check possible occurrence of lung shunt. Holmium also is highly paramagnetic and can be used to obtain images whereby NMR. The glass matrix consists of (P 2 O 5 ) tetrahedrons and can be produced by a relatively lower melting temperature of chemical compounds. The 31 P decays by emitting β- radiation and contributes to the absorbed dose, helping to annihilate the cancer cells. The microspheres were produced by using two methods: the flame and the gravitation falling methods to obtain microspheres with appropriate properties. (author)

  15. Hydrogen transport and storage in engineered glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Rambach, G.D.

    1994-04-20

    New, high-strength, hollow, glass microspheres filled with pressurized hydrogen exhibit storage densities which make them attractive for bulk hydrogen storage and transport. The hoop stress at failure of our engineered glass microspheres is about 150,000 psi, permitting a three-fold increase in pressure limit and storage capacity above commercial microspheres, which fail at wall stresses of 50,000 psi. For this project, microsphere material and structure will be optimized for storage capacity and charge/discharge kinetics to improve their commercial practicality. Microsphere production scale up will be performed, directed towards large-scale commercial use. Our analysis relating glass microspheres for hydrogen transport with infrastructure and economics` indicate that pressurized microspheres can be economically competitive with other forms of bulk rail and truck transport such as hydride beds, cryocarbons and pressurized tube transports. For microspheres made from advanced materials and processes, analysis will also be performed to identify the appropriate applications of the microspheres considering property variables, and different hydrogen infrastructure, end use, production and market scenarios. This report presents some of the recent modelling results for large beds of glass microspheres in hydrogen storage applications. It includes plans for experiments to identify the properties relevant to large-bed hydrogen transport and storage applications, of the best, currently producible, glass microspheres. This work began in March, 1994. Project successes will be manifest in the matching of cur-rent glass microspheres with a useful application in hydrogen bulk transport and storage, and in developing microsphere materials and processes that increase the storage density and reduce the storage energy requirement.

  16. Hydrogen transport and storage in engineered glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Rambach, G.D.

    1995-02-28

    New, high strength glass microspheres filled with pressurized hydrogen exhibit densities which make them attractive for bulk hydrogen storage and transport. The membrane tensile stress at failure for engineered glass microspheres is about 150,000 psi, permitting a three-fold increase in pressure limit and storage capacity above commercial microspheres, which have been studied a decade ago and have been shown to fail at membrane stresses of 50,000 psi. This analysis relating glass microspheres for hydrogen transport with infrastructure and economics, indicate that pressurized microspheres can be economically competitive with other forms of bulk rail and truck transport such as pressurized tube transports and liquid hydrogen trailers. This paper will describe the matching of current glass microspheres with the useful application in commercial hydrogen bulk transport and storage.

  17. Glass microspheres for medical applications

    Science.gov (United States)

    Conzone, Samuel David

    Radioactive dysprosium lithium borate glass microspheres have been developed as biodegradable radiation delivery vehicles for the radiation synovectomy treatment of rheumatoid arthritis. Once injected into a diseased joint, the microspheres deliver a potent dose of radiation to the diseased tissue, while a non-uniform chemical reaction converts the glass into an amorphous, porous, hydrated dysprosium phosphate reaction product. The non-radioactive, lithium-borate component is dissolved from the glass (up to 94% weight loss), while the radioactive 165Dy reacts with phosphate anions in the body fluids, and becomes "chemically" trapped in a solid, dysprosium phosphate reaction product that has the same size as the un-reacted glass microsphere. Ethylene diamine tetraacetate (EDTA) chelation therapy can be used to dissolve the dysprosium phosphate reaction product after the radiation delivery has subsided. The dysprosium phosphate reaction product, which formed in vivo in the joint of a Sprague-Dawley rat, was dissolved by EDTA chelation therapy in 100 Gy) of localized beta radiation to a treatment site within the body, followed by complete biodegradability. The non-uniform reaction process is a desirable characteristic for a biodegradable radiation delivery vehicle, but it is also a novel material synthesis technique that can convert a glass to a highly porous materials with widely varying chemical composition by simple, low-temperature, glass/solution reaction. The reaction product formed by nonuniform reaction occupies the same volume as the un-reacted glass, and after drying for 1 h at 300°C, has a specific surface area of ≈200 m2/g, a pore size of ≈30 nm, and a nominal crushing strength of ≈10 MPa. Finally, rhenium glass microspheres, composed of micron-sized, metallic rhenium particles dispersed within a magnesium alumino borate glass matrix were produced by sintering ReO2 powder and glass frit at 1050°C. A 50 mg injection of radioactive rhenium glass

  18. Treatment of unresectable hepatocellular carcinoma with intrahepatic yttrium 90 microspheres: factors associated with liver toxicities.

    Science.gov (United States)

    Goin, James E; Salem, Riad; Carr, Brian I; Dancey, Janet E; Soulen, Michael C; Geschwind, Jean Francois H; Goin, Kathleen; Van Buskirk, Mark; Thurston, Kenneth

    2005-02-01

    Intraarterial injection of yttrium 90 microspheres (TheraSpheres) is used in the treatment of hepatocellular carcinoma (HCC). This article presents an analysis of the incidence of liver toxicities (liver-related events) and pretreatment factors associated with liver toxicities after TheraSphere treatment. Eighty-eight TheraSphere-treated patients with low 90-day mortality risk were selected for analysis, with liver toxicities coded with use of standard oncology criteria. Descriptive and inferential statistical methods were applied to estimate the incidence of liver toxicities and to evaluate the influence of liver radiation dose and various pretreatment factors on the risk of their occurrence. Sixty-eight liver toxicities occurred in 37 of the 88 patients (42%). Thirty-two patients (36%) experienced 50 liver toxicities after the first treatment and nine of 23 patients (39%) who received a second treatment experienced 18 liver toxicities. Pretreatment total bilirubin and liver radiation dose were found to be associated with the risk of at least one liver toxicity and with the time to first occurrence of a liver toxicity after first treatment. Pretreatment total bilirubin also was associated with liver toxicities after the second treatment. Most of the toxicities resolved; however, those that did not resolve were attributed to tumor progression or advancing cirrhosis. The risk of liver toxicities in patients with unresectable HCC treated with TheraSpheres increases with increasing pretreatment total bilirubin level and liver radiation dose to a maximum of 150 Gy for a single administration. The toxicities attributed to treatment resolved over time, and none of the patients studied had confirmed radiation-induced liver disease. Consequently, doses as high as 150 Gy on a single administration and as high as 268 Gy on repeated administrations were well tolerated.

  19. Innovative hydrogen storage in hollow glass-microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Keding, M.; Schmid, G.; Tajmar, M. [Austrian Research Centers, Vienna (Austria)

    2009-07-01

    Hydrogen storage technologies are becoming increasingly important for a number of future applications. The Austrian Research Centers (ARC) are developing a unique hydrogen storage system that combines the advantages of both hollow glass microsphere and chemical compound hydrogen storage, but eliminates their respective drawbacks. Water is utilized as a functional liquid to carry the hollow glass microspheres that are loaded with up to 700 bar of hydrogen gas. Sodium borohydride (NaBH{sub 4}) is then injected together with the glass microspheres into a reaction chamber where the water reacts catalytically with the NaBH{sub 4} producing hydrogen and heat. The heat is then utilized to release the hydrogen from the hollow glass microspheres providing a double hydrogen generation process without any external energy or heat during storage or gas release. The paper described this hydrogen storage system with particular reference to microspheres, the coating process, the experimental facility and NaBH{sub 4} test results. It was concluded that hydrogen storage and production on demand is possible with microspheres and sodium borohydride solution. 9 refs., 16 figs.

  20. WE-AB-BRA-05: PET-Guided Delivery Quality Evaluation of Yttrium-90 Microsphere Radioembolizaton for Hepatocellular Carcinoma Patients: The Optimal Sequence of Radioembolizaton and Chemoembolization Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Lin, M [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States); Saboury, B [University of Maryland School of Medicine, Baltimore, MD (United States)

    2016-06-15

    Purpose: Selective-internal-radiation-therapy (SIRT) and transarterial-chemoembolization (TACE) are commonly used for treatment of liver tumors. The use of TACE, which is macroembolic, prior to SIRT may cause hemodynamic changes in tumor vasculature that impair yttrium-90 (90Y) microsphere delivery to the targeted lesions. This work aims to quantify dosimetric tumor coverage using 90Y positron emission tomography (PET) dosimetry after SIRT alone compared to TACE followed by SIRT. Methods: A total of 40 consecutive hepatocellular carcinoma (HCC) SIRT patients who had a post-SIRT 90Y PET/CT scan were evaluated. The patient-specific-3D-dose was reconstructed from the PET images. Patients were categorized into two groups: patients received TACE prior SIRT procedure (n=18) and patient received SIRT alone (n=22). The lesions and liver were delineated by a senior radiologist. We evaluated both the lesion-specific dose-volume-histogram (DVH) and the selectivity index (SI) defined as the ratio of the average dose inside the total lesion(s) and the average dose of the normal liver. The SI values of patients were compared based on whether TACE was previously used. Results: A wide spectrum was observed in the lesion-specific DVH-evaluation and SI appeared to be suitable of evaluating the quality of each SIRT infusion. The average SI of the entire patient group was 3.0, i.e. targeted lesion receiving three times higher dose than normal liver. The average SI was 1.8 for patients who had prior TACE and 3.9 for patients who did not have prior TACE (p=0.008). 85% of the patients with prior TACE demonstrated poor 90Y-microsphere delivery (SI <2) while none demonstrated excellent delivery (SI >4). On the other hand, the incidence SI >4 among patients with no prior TACE was 37%. Conclusion: 3D dose evaluation using post-SIRT PET suggests that 90Y microsphere delivery to liver tumors is impaired among patients who received prior TACE compared to those who receive SIRT alone.

  1. Hollow porous-wall glass microspheres for hydrogen storage

    Science.gov (United States)

    Heung, Leung K.; Schumacher, Ray F.; Wicks, George G.

    2010-02-23

    A porous wall hollow glass microsphere is provided having a diameter range of between 1 to 200 microns, a density of between 1.0 to 2.0 gm/cc, a porous-wall structure having wall openings defining an average pore size of between 10 to 1000 angstroms, and which contains therein a hydrogen storage material. The porous-wall structure facilitates the introduction of a hydrogen storage material into the interior of the porous wall hollow glass microsphere. In this manner, the resulting hollow glass microsphere can provide a membrane for the selective transport of hydrogen through the porous walls of the microsphere, the small pore size preventing gaseous or liquid contaminants from entering the interior of the hollow glass microsphere.

  2. A Woman with Black Beads in Her Stomach: Severe Gastric Ulceration Caused by Yttrium-90 Radioembolization

    Directory of Open Access Journals (Sweden)

    Indu S. Voruganti

    2018-01-01

    Full Text Available Radioembolization (RE is a selective internal radiation therapy (SIRT delivering targeted, high-dose, intra-arterial radiation directly to the vascular supply of liver tumors. Complications can occur due to aberrant deposition or migration of radiation microspheres into nontarget locations, including normal hepatic parenchyma, lungs, pancreas, and upper gastrointestinal (UGI tract. We report a case of gastric ulcers due to yttrium-90 (90Y seed migration to the stomach to alert clinicians to this rare cause of gastric injury. A 57-year-old woman with stage IV breast cancer with liver and lung metastases presented to the hospital with 2 months of worsening nausea and vomiting. Two months prior, she had received SIRT with 90Y microspheres without complications. Upper GI endoscopy showed diffuse gastritis and extensive antral ulceration. Biopsies revealed black, spherical foreign bodies, consistent with 90Y microspheres, documenting radiation injury. Radiation-induced UGI ulceration is caused by direct radiation injury from beta-radiation. Delay in diagnosis may be due to the nonspecificity of symptoms and temporal delay of symptom onset from SIRT, which was 2 months in our patient. Also, complaints may be attributed erroneously to adjuvant chemotherapy or widespread metastatic disease. Clinicians must consider radiation-associated toxicity in any SIRT-treated patient developing abdominal symptoms.

  3. Hydrogen transport and storage in engineered glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Rambach, G.D.

    1995-04-18

    New, high strength glass microspheres filled with pressurized hydrogen exhibit densities which make them attractive for bulk hydrogen storage and transport. The membrane tensile stress at failure for our engineered glass microspheres is about 150,000 psi, permitting a threefold increase in pressure limit and storage capacity above commercial microspheres, which have been studied a decade ago and have been shown to fail at membrane stresses of 50,000 psi. Our analysis relating glass microspheres for hydrogen transport with infrastructure and economics, indicate that pressurized microspheres can be economically competitive with other forms of bulk rail and truck transport such as pressurized tube transports and liquid hydrogen trailers.

  4. PET/MRI of Hepatic 90Y Microsphere Deposition Determines Individual Tumor Response

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, Kathryn J. [Washington University, Department of Radiology (United States); Maughan, Nichole M. [Washington University, Department of Biomedical Engineering (United States); Laforest, Richard [Washington University, Department of Nuclear Medicine (United States); Saad, Nael E. [Washington University, Department of Radiology (United States); Sharma, Akash [Washington University, Department of Nuclear Medicine (United States); Olsen, Jeffrey; Speirs, Christina K.; Parikh, Parag J., E-mail: parikh@wustl.edu [Washington University, Department of Radiation Oncology (United States)

    2016-06-15

    PurposeThe purpose of our study is to determine if there is a relationship between dose deposition measured by PET/MRI and individual lesion response to yttrium-90 ({sup 90}Y) microsphere radioembolization.Materials and Methods26 patients undergoing lobar treatment with {sup 90}Y microspheres underwent PET/MRI within 66 h of treatment and had follow-up imaging available. Adequate visualization of tumor was available in 24 patients, and contours were drawn on simultaneously acquired PET/MRI data. Dose volume histograms (DVHs) were extracted from dose maps, which were generated using a voxelized dose kernel. Similar contours to capture dimensional and volumetric change of tumors were drawn on follow-up imaging. Response was analyzed using both RECIST and volumetric RECIST (vRECIST) criteria.ResultsA total of 8 hepatocellular carcinoma (HCC), 4 neuroendocrine tumor (NET), 9 colorectal metastases (CRC) patients, and 3 patients with other metastatic disease met inclusion criteria. Average dose was useful in predicting response between responders and non-responders for all lesion types and for CRC lesions alone using both response criteria (p < 0.05). D70 (minimum dose to 70 % of volume) was also useful in predicting response when using vRECIST. No significant trend was seen in the other tumor types. For CRC lesions, an average dose of 29.8 Gy offered 76.9 % sensitivity and 75.9 % specificity for response.ConclusionsPET/MRI of {sup 90}Y microsphere distribution showed significantly higher DVH values for responders than non-responders in patients with CRC. DVH analysis of {sup 90}Y microsphere distribution following treatment may be an important predictor of response and could be used to guide future adaptive therapy trials.

  5. Utility of Quantitative 99mTc-MAA SPECT/CT for 90yttrium-Labelled Microsphere Treatment Planning: Calculating Vascularized Hepatic Volume and Dosimetric Approach

    Science.gov (United States)

    Garin, Etienne; Rolland, Yan; Lenoir, Laurence; Pracht, Marc; Mesbah, Habiba; Porée, Philippe; Laffont, Sophie; Clement, Bruno; Raoul, Jean-Luc; Boucher, Eveline

    2011-01-01

    Objectives. The aim of this study was to assess the effectiveness of SPECT/CT for volume measurements and to report a case illustrating the major impact of SPECT/CT in calculating the vascularized liver volume and dosimetry prior to injecting radiolabelled yttrium-90 microspheres (Therasphere). Materials and Methods. This was a phantom study, involving volume measurements carried out by two operators using SPECT and SPECT/CT images. The percentage of error for each method was calculated, and interobserver reproducibility was evaluated. A treatment using Therasphere was planned in a patient with three hepatic arteries, and the quantitative analysis of SPECT/CT for this patient is provided. Results. SPECT/CT volume measurements proved to be accurate (mean error Therasphere used. Conclusions. MAA SPECT/CT is accurate for vascularized liver volume measurements, providing a valuable contribution to the therapeutic planning of patients with complex hepatic vascularization. PMID:21822489

  6. Non-target activity detection by post-radioembolization yttrium-90 PET/CT: Image assessment technique and case examples

    Directory of Open Access Journals (Sweden)

    Yung Hsiang eKao

    2014-02-01

    Full Text Available High-resolution yttrium-90 (90Y imaging of post-radioembolization microsphere biodistribution may be achieved by conventional positron emission tomography with integrated computed tomography (PET/CT scanners that have time-of-flight capability. However, reconstructed 90Y PET/CT images have high background noise, making non-target activity detection technically challenging. This educational article describes our image assessment technique for non-target activity detection by 90Y PET/CT which qualitatively overcomes the problem of background noise. We present selected case examples of non-target activity in untargeted liver, stomach, gallbladder, chest wall and kidney, supported by angiography and 90Y bremsstrahlung single photon emission computed tomography with integrated computed tomography (SPECT/CT or technetium-99m macroaggregated albumin SPECT/CT.

  7. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    International Nuclear Information System (INIS)

    Morshedi, Maud M.; Bauman, Michael; Rose, Steven C.; Kikolski, Steven G.

    2015-01-01

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization

  8. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    Energy Technology Data Exchange (ETDEWEB)

    Morshedi, Maud M., E-mail: maud.morshedi@my.rfums.org; Bauman, Michael, E-mail: mbauman@ucsd.edu; Rose, Steven C., E-mail: scrose@ucsd.edu; Kikolski, Steven G., E-mail: skikolski@gmail.com [University of California San Diego Health Sciences, Radiology Department, University of California San Diego Medical Center (United States)

    2015-04-15

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.

  9. Yttrium aluminum garnet coating on glass substrate

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Camila M.A.; Freiria, Gabriela S.; Faria, Emerson H. de; Rocha, Lucas A.; Ciuffi, Katia J.; Nassar, Eduardo J., E-mail: eduardo.nassar@unifran.edu.br

    2016-02-15

    Thin luminescent films have seen great technological advances and are applicable in the production of a variety of materials such as sensors, solar cells, photovoltaic devices, optical magnetic readers, waveguides, lasers, and recorders. Systems that contain yttrium aluminum oxide are important hosts for lanthanide ions and serve as light emission devices. This work deals with the deposition of yttrium aluminum garnet (YAG) film doped with Eu{sup 3+} onto a glass substrate obtained by the sol–gel methodology. Spray pyrolysis furnished the yttrium aluminum oxide powder. Dip-coating at a withdrawal speed of 10 mm min{sup −1} and evaporation led to deposition of different numbers of layers of the YAG:Eu{sup 3+} film onto the glass substrate from a YAG:Eu{sup 3+} powder suspension containing ethanol, water, and tetraethylorthosilicate. Photoluminescence, X-ray diffraction, scanning electron microscopy, and transparency measurements aided film characterization. The emission spectra revealed that the number of layers influenced film properties. - Highlights: • The spray pyrolysis was used to obtain luminescent YAG:Eu{sup 3+}. • The matrix was deposited as transparent films. • The YAG:Eu{sup 3+} was deposited by sol–gel process onto glass substrate.

  10. Yttrium aluminum garnet coating on glass substrate

    International Nuclear Information System (INIS)

    Ferreira, Camila M.A.; Freiria, Gabriela S.; Faria, Emerson H. de; Rocha, Lucas A.; Ciuffi, Katia J.; Nassar, Eduardo J.

    2016-01-01

    Thin luminescent films have seen great technological advances and are applicable in the production of a variety of materials such as sensors, solar cells, photovoltaic devices, optical magnetic readers, waveguides, lasers, and recorders. Systems that contain yttrium aluminum oxide are important hosts for lanthanide ions and serve as light emission devices. This work deals with the deposition of yttrium aluminum garnet (YAG) film doped with Eu 3+ onto a glass substrate obtained by the sol–gel methodology. Spray pyrolysis furnished the yttrium aluminum oxide powder. Dip-coating at a withdrawal speed of 10 mm min −1 and evaporation led to deposition of different numbers of layers of the YAG:Eu 3+ film onto the glass substrate from a YAG:Eu 3+ powder suspension containing ethanol, water, and tetraethylorthosilicate. Photoluminescence, X-ray diffraction, scanning electron microscopy, and transparency measurements aided film characterization. The emission spectra revealed that the number of layers influenced film properties. - Highlights: • The spray pyrolysis was used to obtain luminescent YAG:Eu 3+ . • The matrix was deposited as transparent films. • The YAG:Eu 3+ was deposited by sol–gel process onto glass substrate.

  11. Yttrium-90 - ED 4310

    International Nuclear Information System (INIS)

    Ammerich, M.; Frot, P.; Gambini, D.; Gauron, C.; Moureaux, P.; Herbelet, G.; Lahaye, T.; Pihet, P.; Rannou, A.; Vidal, E.

    2013-03-01

    This sheet presents the characteristics of yttrium-90, its origin, and its radio-physical and biological properties. It briefly describes its use in nuclear medicine. It indicates its dosimetric parameters for external exposure, cutaneous contamination, and internal exposure due to acute contamination or to chronic contamination. It indicates and comments the various exposure control techniques: ambient dose rate measurement, surface contamination measurement, atmosphere contamination. It addresses the means of protection: premise design, protection against external exposure and against internal exposure. It describes how areas are delimited and controlled within the premises: regulatory areas, controls to be performed. It addresses the personnel classification, training and medical survey. It addresses the issue of solid and liquid wastes and liquid or gaseous effluents. It briefly recalls the administrative procedures related to the authorization and declaration of possession and use of sealed and unsealed sources. It indicates regulatory aspects related to the transport of yttrium-90, describes what is to be done in case of incident or accident (for the different types of contamination or exposure)

  12. Radioembolization using 90Y-resin microspheres for patients with advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Sangro, Bruno; Bilbao, Jose I.; Boan, Jose; Martinez-Cuesta, Antonio; Benito, Alberto; Rodriguez, Javier; Panizo, Angel; Gil, Belen; Inarrairaegui, Mercedes; Herrero, Ignacio; Quiroga, Jorge; Prieto, Jesus

    2006-01-01

    Purpose: To investigate the antitumor effect of resin microspheres loaded with 90-yttrium against hepatocellular carcinoma and their safety in the setting of liver cirrhosis. Patients and Methods: Data from 24 consecutive patients with hepatocellular carcinoma (HCC) treated by radioembolization in the period from September 2003 to February 2005 were reviewed. Patients received no further antineoplastic therapy. A comprehensive evaluation was performed to prevent the risk of damage due to microsphere misplacing. Patients were discharged the day after microspheres injection. Results: Serious liver toxicity observed among cirrhotic patients in a first period was subsequently prevented by modifying the selection criteria and the method for calculating the activity to be administered. Among 21 patients evaluable for response using Response Evaluation Criteria in Solid Tumors (RECIST) criteria, a reduction in size of target lesions was observed in all but 1 patient. When considering only target lesions, disease control rate and response rate were 100% and 23.8%, respectively. However, 43% of patients progressed in the liver in the form of new lesions appearing a median time of 3 months after radioembolization. Conclusion: Our experience in these series of patients indicates that radioembolization using resin microspheres has a significant antitumor effect against HCC and that using stringent selection criteria and conservative models for calculating Radiation activity to be administered, radioembolization can be performed safely even in cirrhotic patients

  13. Radiation protection data sheets for the use of Strontium 90-Yttrium 90 in unsealed sources

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This radiation protection data sheet is intended for supervisors and staff in the different medical, hospital, pharmaceutical, university and industrial laboratories and departments where Strontium 90-Yttrium 90 is handled, and also for all those involved in risk prevention in this field. It provides essential data on radiation protection measures during the use of Strontium 90-Yttrium 90 in unsealed sources: physical characteristics, risk assessment, administrative procedures, recommendations, regulations and bibliography

  14. Preparation and characterization of composite microspheres for brachytherapy and hyperthermia treatment of cancer

    International Nuclear Information System (INIS)

    Zhao Di; Huang Wenhai; Rahaman, Mohamed N.; Day, Delbert E.; Wang Deping; Gu Yifei

    2012-01-01

    Composite microspheres were prepared by coating yttrium–aluminum–silicate (YAS) glass microspheres (20–30 μm) with a layer of Fe 3 O 4 nanoparticles and evaluated for potential use in brachytherapy and hyperthermia treatment of cancer. After neutron activation to form the β-emitting 90 Y radionuclide, the composite microspheres can be injected into a patient to destroy cancerous tumors; at the same time, the composite microspheres can generate heat upon application of a magnetic field to also destroy the tumors. The results showed that the composite microspheres were chemically durable when immersed in a simulated body fluid (SBF), with ∼ 0.25% weight loss and ∼ 3.2% yttrium dissolved into the SBF after 30 days at 37 °C. The composite microspheres also showed ferromagnetic properties as a result of the Fe 3 O 4 coating; when immersed in water at 20 °C (20 mg in 1 mL of water), the application of an alternating magnetic field produced a temperature increase from 20 °C to 38−46 °C depending on the thickness of the Fe 3 O 4 coating. The results indicate that these composite microspheres have promising potential in combined brachytherapy and hyperthermia treatment of cancerous tumors. - Highlights: ► Composite microspheres for brachytherapy and hyperthermia treatment of cancer. ► Fe 3 O 4 nanoparticles coated on the yttrium–aluminum–silicate glass microspheres. ► Microspheres are chemically stable in SBF. ► Microspheres can generate heat for hyperthermia under an alternating magnetic field. ► Microspheres can emit β-rays for brachytherapy after neutron activation.

  15. Porous-wall hollow glass microspheres as carriers for biomolecules

    Science.gov (United States)

    Li, Shuyi; Dynan, William S; Wicks, George; Serkiz, Steven

    2013-09-17

    The present invention includes compositions of porous-wall hollow glass microspheres and one or more biomolecules, wherein the one or more biomolecules are positioned within a void location within the hollow glass microsphere, and the use of such compositions for the diagnostic and/or therapeutic delivery of biomolecules.

  16. Radioembolization with Yttrium-90 microspheres for patients with unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Bhangoo, Munveer Singh; Karnani, Diraj R; Hein, Paul N; Giap, Huan; Knowles, Harry; Issa, Chris; Steuterman, Steve; Pockros, Paul; Frenette, Catherine

    2015-10-01

    Hepatocellular carcinoma (HCC) is aggressive primary malignancy of the liver that most commonly presents late in the disease course. As a result, the majority of patients are not candidates for curative therapies. Locoregional therapies including Yttrium-90 (Y-90) radioembolization play an important role in management of the vast majority of patients with HCC. Patients with unnresectable HCC (n=17) treated with Y-90 radioembolization from 2005 to 2014 were evaluated retrospectively. Data was abstracted from medical records including patient charts, laboratory data, and imaging. Toxicities were recorded using Common Terminology Criteria 3.0. Response was recorded according to modified RECIST (mRECIST) criteria. Seventeen patients received 33 treatments with Y-90 radioembolization. A majority (65%) received TheraSphere with a minority (35%) receiving SIR-Spheres. The median treatment activity delivered was 1.725 gBq (range, 1.4-2.5 gBq). The median treatment dose delivered was 100 Gy (range, 90-120 Gy). The median lung shunt fraction was 2.02% (range, 1.5-4.1%). The most common clinical toxicity among all patients was nausea and vomiting (59%), primarily grade 1 and 2. Other post-treatment findings included abdominal pain (29%), fatigue (53%), and weight loss (18%). One patient developed a grade 5 gastric ulcer after the treatment. A clinical benefit, defined as patients achieving complete response (CR), partial response (PR) or stable disease (SD), was seen in 48% of patients. PR was seen in 24% of cases; progressive disease (PD) was noted in 35%. Patients survived for a median of 8.4 months (range, 1.3 to 21.1 months) after the first radioembolization treatment. Median survival after Y-90 treatment was 8.4 months among patients treated TheraSphere as compared with 7.8 months in patients treated with SIR-Spheres. The mean overall survival from the time of diagnosis was 11.7 months (range, 3.4 to 43.2 months). For patients with unresectable HCC, Y-90

  17. The prognostic value of functional and anatomical parameters for the selection of patients receiving yttrium-90 microspheres for the treatment of liver cancer

    Science.gov (United States)

    Mesoloras, Geraldine

    Yttrium-90 (90Y) microsphere therapy is being utilized as a treatment option for patients with primary and metastatic liver cancer due to its ability to target tumors within the liver. The success of this treatment is dependent on many factors, including the extent and type of disease and the nature of prior treatments received. Metabolic activity, as determined by PET imaging, may correlate with the number of viable cancer cells and reflect changes in viable cancer cell volume. However, contouring of PET images by hand is labor intensive and introduces an element of irreproducibility into the determination of functional target/tumor volume (FTV). A computer-assisted method to aid in the automatic contouring of FTV has the potential to substantially improve treatment individualization and outcome assessment. Commercial software to determine FTV in FDG-avid primary and metastatic liver tumors has been evaluated and optimized. Volumes determined using the automated technique were compared to those from manually drawn contours identified using the same cutoff in the standard uptake value (SUV). The reproducibility of FTV is improved through the introduction of an optimal threshold value determined from phantom experiments. Application of the optimal threshold value from the phantom experiments to patient scans was in good agreement with hand-drawn determinations of the FTV. It is concluded that computer-assisted contouring of the FTV for primary and metastatic liver tumors improves reproducibility and increases accuracy, especially when combined with the selection of an optimal SUV threshold determined from phantom experiments. A method to link the pre-treatment assessment of functional (PET based) and anatomical (CT based) parameters to post-treatment survival and time to progression was evaluated in 22 patients with colorectal cancer liver metastases treated using 90Y microspheres and chemotherapy. The values for pre-treatment parameters that were the best

  18. Boosted selective internal radiation therapy with 90Y-loaded glass microspheres (B-SIRT) for hepatocellular carcinoma patients: a new personalized promising concept

    International Nuclear Information System (INIS)

    Garin, E.; Lenoir, L.; Edeline, J.; Laffont, S.; Mesbah, H.; Poree, P.; Sulpice, L.; Boudjema, K.; Mesbah, M.; Guillygomarc'h, A.; Quehen, E.; Pracht, M.; Raoul, J.L.; Clement, B.; Rolland, Y.; Boucher, E.

    2013-01-01

    To evaluate the impact of dosimetry based on MAA SPECT/CT for the prediction of response, toxicity and survival, and for treatment planning in patients with hepatocellular carcinoma (HCC) treated with 90 Y-loaded glass microspheres (TheraSphere registered). TheraSphere registered was administered to 71 patients with inoperable HCC. MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), healthy injected liver dose (HILD), and total injected liver dose. Response was evaluated at 3 months using EASL criteria. Time to progression (TTP) and overall survival (OS) were evaluated using the Kaplan-Meier method. Factors potentially associated with liver toxicity were combined to construct a liver toxicity score (LTS). The response rate was 78.8 %. Median TD were 342 Gy for responding lesions and 191 Gy for nonresponding lesions (p 205 Gy (p = 0.0015 and not significant). Among patients with portal vein thrombosis (PVT) (n = 33), the median TTP and OS were 4.5 months (2-7 months) and 5 months (2-8 months), respectively, in patients with TD 205 Gy (p = 0.039 and 0.005). The median OS was 24.5 months (18-28.5 months) in PVT patients with TD >205 Gy and good PVT targeting on MAA SPECT/CT. The LTS was able to detect severe liver toxicity (n = 6) with a sensitivity of 83 % and overall accuracy of 97 %. Dosimetry based on MAA SPECT/CT was able to accurately predict response and survival in patients treated with glass microspheres. This method can be used to adapt the injected activity without increasing liver toxicity, thus defining a new concept of boosted selective internal radiation therapy (B-SIRT). This new concept and LTS enable fully personalized treatment planning with glass microspheres to be achieved. (orig.)

  19. Boosted selective internal radiation therapy with 90Y-loaded glass microspheres (B-SIRT) for hepatocellular carcinoma patients: a new personalized promising concept.

    Science.gov (United States)

    Garin, E; Lenoir, L; Edeline, J; Laffont, S; Mesbah, H; Porée, P; Sulpice, L; Boudjema, K; Mesbah, M; Guillygomarc'h, A; Quehen, E; Pracht, M; Raoul, J L; Clement, B; Rolland, Y; Boucher, E

    2013-07-01

    To evaluate the impact of dosimetry based on MAA SPECT/CT for the prediction of response, toxicity and survival, and for treatment planning in patients with hepatocellular carcinoma (HCC) treated with (90)Y-loaded glass microspheres (TheraSphere®). TheraSphere® was administered to 71 patients with inoperable HCC. MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), healthy injected liver dose (HILD), and total injected liver dose. Response was evaluated at 3 months using EASL criteria. Time to progression (TTP) and overall survival (OS) were evaluated using the Kaplan-Meier method. Factors potentially associated with liver toxicity were combined to construct a liver toxicity score (LTS). The response rate was 78.8%. Median TD were 342 Gy for responding lesions and 191 Gy for nonresponding lesions (p 205 Gy (p = 0.0015 and not significant). Among patients with portal vein thrombosis (PVT) (n = 33), the median TTP and OS were 4.5 months (2-7 months) and 5 months (2-8 months), respectively, in patients with TD 205 Gy (p = 0.039 and 0.005). The median OS was 24.5 months (18-28.5 months) in PVT patients with TD >205 Gy and good PVT targeting on MAA SPECT/CT. The LTS was able to detect severe liver toxicity (n = 6) with a sensitivity of 83% and overall accuracy of 97%. Dosimetry based on MAA SPECT/CT was able to accurately predict response and survival in patients treated with glass microspheres. This method can be used to adapt the injected activity without increasing liver toxicity, thus defining a new concept of boosted selective internal radiation therapy (B-SIRT). This new concept and LTS enable fully personalized treatment planning with glass microspheres to be achieved.

  20. Yttrium-90

    International Nuclear Information System (INIS)

    Ammerich, Marc; Frot, Patricia; Gambini, Denis-Jean; Gauron, Christine; Moureaux, Patrick; Herbelet, Gilbert; Lahaye, Thierry; Pihet, Pascal; Rannou, Alain; Vial, Eric

    2013-03-01

    This sheet belongs to a collection which relates to the use of radionuclides essentially in unsealed sources. Its goal is to gather on a single document the most relevant information as well as the best prevention practices to be implemented. These sheets are made for the persons in charge of radiation protection: users, radioprotection-skill persons, labor physicians. Each sheet treats of: 1 - the radio-physical and biological properties; 2 - the main uses; 3 - the dosimetric parameters; 4 - the measurement; 5 - the protection means; 6 - the areas delimitation and monitoring; 7 - the personnel classification, training and monitoring; 8 - the effluents and wastes; 9 - the authorization and declaration administrative procedures; 10 - the transport; and 11 - the right conduct to adopt in case of incident or accident. This sheet deals specifically with Yttrium-90

  1. Quality of life in patients diagnosed with primary hepatocellular carcinoma: hepatic arterial infusion of Cisplatin versus 90-Yttrium microspheres (Therasphere).

    Science.gov (United States)

    Steel, Jennifer; Baum, Andrew; Carr, Brian

    2004-02-01

    The aims of the study were to test the difference in health-related quality (HRQL) of life and survival in patients diagnosed with primary hepatocellular carcionma (HCC) and treated with either hepatic arterial infusion (HAI) of Cisplatin or 90-Yttrium microspheres (Therasphere). The design of the study was a non-randomized parallel cohort study. Twenty-eight patients participated in the present study. HRQL was assessed by administration of the Functional Assessment of Cancer Therapy-Hepatobiliary. Survival was measured using Kaplan Meier methods. The results of present study suggest treatment with Therasphere) had an advantage in regard to HRQL and survival when compared to Cisplatin. At 3-month follow-up, patients who were treated with Therasphere had a higher level of functional well-being as well as overall quality of life when compared to patients treated with Cisplatin. At 6-month follow-up patients (treated with Therasphere) continued to have better functional well-being when compared to patients being treated with HAI of Cisplatin. At 6-month follow-up, survival was found to be similar for patients treated with Therasphere when compared to patients being treated with Cisplatin. Preliminary data suggest that treatment with Therasphere has a modest advantage in regard to HRQL when compared patients treated with HAI of Cisplatin. Future research with Therasphere, that includes a larger sample size and longer follow-up, is necessary to make definitive conclusions regarding the efficacy and effect on HRQL. Copyright 2003 John Wiley & Sons, Ltd.

  2. Treatment of unresectable primary and metastatic liver cancer with yttrium-90 microspheres (TheraSphere): assessment of hepatic arterial embolization.

    Science.gov (United States)

    Sato, Kent; Lewandowski, Robert J; Bui, James T; Omary, Reed; Hunter, Russell D; Kulik, Laura; Mulcahy, Mary; Liu, David; Chrisman, Howard; Resnick, Scott; Nemcek, Albert A; Vogelzang, Robert; Salem, Riad

    2006-01-01

    In Canada and Europe, yttrium-90 microspheres (TheraSphere); MDS Nordion, Ottawa, Canada) are a primary treatment option for primary and secondary hepatic malignancies. We present data from 30 patients with hepatocellular carcinoma (HCC) and metastatic liver disease treated with TheraSphere from a single academic institution to evaluate the angiographically evident embolization that follows treatment. Seven interventional radiologists from one treatment center compared pretreatment and posttreatment angiograms. The reviewers were blinded to the timing of the studies. The incidence of postembolization syndrome (PES) was determined as well as objective tumor response rates by the World Health Organization (WHO), Response Evaluation Criteria in Solid Tumors (RECIST), and European Association for the Study of the Liver (EASL) criteria. There were 420 independent angiographic observations that were assessed using the chi-squared statistic. The pretreatment and posttreatment angiograms could not be correctly identified on average more than 43% of the time (p = 0.0004). The postprocedure arterial patency rate was 100%. The objective tumor response rates for all patients were 24%, 31%, and 72% for WHO, RECIST, and EASL criteria, respectively. All of the patients tolerated the procedure without complications and were treated on an outpatient basis, and four patients had evidence of PES. This treatment method does not result in macroscopic embolization of the hepatic arteries, thereby maintaining hepatic tissue perfusion. These data support the principle that the favorable response rates reported with TheraSphere are likely due to radiation and microscopic embolization rather than flow-related macroscopic embolization and ischemia.

  3. Automated characterization of glass microspheres used for laser fusion experiments

    International Nuclear Information System (INIS)

    Tajima, Tsuyoshi; Norimatsu, Takayoshi; Izawa, Yasukazu; Yamanaka, Chiyoe.

    1985-01-01

    In laser fusion experiments glass microspheres of 100 to 1000 μm in diameter and 1 to 20 μm in wall thickness are most commonly used as fuel containers. The glass microspheres should be characterized precisely to meet stringent experimental requirements. Much time is consumed to characterize and select good quality spheres among thousands of spheres. We have developed an automated system to characterize and select glass microspheres. The system consists of charger, quadrupole rail, image processing and X-Y stage control with micro-computer. Total processing time primarily depends on the time required for image analysis, which should be compromised with the accuracy of characterization. The time for simple characterization requires about 10 sec. at present. (author)

  4. Power output and efficiency of beta-emitting microspheres

    International Nuclear Information System (INIS)

    Cheneler, David; Ward, Michael

    2015-01-01

    Current standard methods to calculate the dose of radiation emitted during medical applications by beta-minus emitting microspheres rely on an over-simplistic formalism. This formalism is a function of the average activity of the radioisotope used and the physiological dimensions of the patient only. It neglects the variation in energy of the emitted beta particle due to self-attenuation, or self-absorption, effects related to the finite size of the sphere. Here it is assumed the sphere is comprised of a pure radioisotope with beta particles being emitted isotropically throughout the material. The full initial possible kinetic energy distribution of a beta particle is taken into account as well as the energy losses due to scattering by other atoms in the microsphere and bremsstrahlung radiation. By combining Longmire’s theory of the mean forward range of charged particles and the Rayleigh distribution to take into account the statistical nature of scattering and energy straggling, the linear attenuation, or self-absorption, coefficient for beta-emitting radioisotopes has been deduced. By analogy with gamma radiation transport in spheres, this result was used to calculate the rate of energy emitted by a beta-emitting microsphere and its efficiency. Comparisons to standard point dose kernel formulations generated using Monte Carlo data show the efficacy of the proposed method. Yttrium-90 is used as a specific example throughout, as a medically significant radioisotope, frequently used in radiation therapy for treating cancer. - Highlights: • Range-energy relationship for the beta particles in yttrium-90 is calculated. • Formalism for the semi-analytical calculation of self-absorption coefficients. • Energy-dependent self-absorption coefficient calculated for yttrium-90. • Flux rate of beta particles from a self-attenuating radioactive sphere is shown. • The efficiency of beta particle emitting radioactive microspheres is calculated

  5. Lead recovery and glass microspheres synthesis from waste CRT funnel glasses through carbon thermal reduction enhanced acid leaching process.

    Science.gov (United States)

    Mingfei, Xing; Yaping, Wang; Jun, Li; Hua, Xu

    2016-03-15

    In this study, a novel process for detoxification and reutilization of waste cathode ray tube (CRT) funnel glass was developed by carbon thermal reduction enhanced acid leaching process. The key to this process is removal of lead from the CRT funnel glass and synchronous preparation of glass microspheres. Carbon powder was used as an isolation agent and a reducing agent. Under the isolation of the carbon powder, the funnel glass powder was sintered into glass microspheres. In thermal reduction, PbO in the funnel glass was first reduced to elemental Pb by carbon monoxide and then located on the surface of glass microspheres which can be removed easily by acid leaching. Experimental results showed that temperature, carbon adding amount and holding time were the major parameters that controlled lead removal rate. The maximum lead removal rate was 94.80% and glass microspheres that measured 0.73-14.74μm were obtained successfully by setting the temperature, carbon adding amount and holding time at 1200°C, 10% and 30min, respectively. The prepared glass microspheres may be used as fillers in polymer materials and abrasive materials, among others. Accordingly, this study proposed a practical and economical process for detoxification and recycling of waste lead-containing glass. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Clinical feasibility of {sup 90}Y digital PET/CT for imaging microsphere biodistribution following radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Chadwick L.; Binzel, Katherine; Zhang, Jun; Knopp, Michael V. [The Ohio State University Wexner Medical Center, Wright Center of Innovation in Biomedical Imaging, Department of Radiology, Columbus, OH (United States); Wuthrick, Evan J. [The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Columbus, OH (United States)

    2017-07-15

    The purpose of this study was to evaluate the clinical feasibility of next generation solid-state digital photon counting PET/CT (dPET/CT) technology and imaging findings in patients following {sup 90}Y microsphere radioembolization in comparison with standard of care (SOC) bremsstrahlung SPECT/CT (bSPECT/CT). Five patients underwent SOC {sup 90}Y bremsstrahlung imaging immediately following routine radioembolization with 3.5 ± 1.7 GBq of {sup 90}Y-labeled glass microspheres. All patients also underwent dPET/CT imaging at 29 ± 11 h following radioembolization. Matched pairs comparison was used to compare image quality, image contrast and {sup 90}Y biodistribution between dPET/CT and bSPECT/CT images. Volumetric assessments of {sup 90}Y activity using different isocontour thresholds on dPET/CT and bSPECT/CT images were also compared. Digital PET/CT consistently provided better visual image quality and {sup 90}Y-to-background image contrast while depicting {sup 90}Y biodistribution than bSPECT/CT. Isocontour volumetric assessment using a 1% threshold precisely outlined {sup 90}Y activity and the treatment volume on dPET/CT images, whereas a more restrictive 20% threshold on bSPECT/CT images was needed to obtain comparable treatment volumes. The use of a less restrictive 10% threshold isocontour on bSPECT/CT images grossly overestimated the treatment volume when compared with the 1% threshold on dPET/CT images. Digital PET/CT is clinically feasible for the assessment of {sup 90}Y microsphere biodistribution following radioembolization, and provides better visual image quality and image contrast than routine bSPECT/CT with comparable acquisition times. With further optimization and clinical validation, dPET technology may allow faster and more accurate imaging-based assessment of {sup 90}Y microsphere biodistribution. (orig.)

  7. Treatment of rheumatoid arthritis with 90yttrium. Follow up studies

    International Nuclear Information System (INIS)

    Teuber, J.; Baenkler, H.W.; Regler, G.; Erlangen-Nuernberg Univ., Erlangen

    1978-01-01

    90 Yttrium-silicate was injected into 131 knee-joints from patients with rheumatoid arthritis with stadium II-IV according to Steinbrocker. The observation period lasted until two years. After three months about 80% and after 24 months still more than 50% of the patients treated showed complete or partial remission. Side-effects as formerly observed with 198 -goldpreparations did not occur. Therefore the treatment with 90 Yttrium-silicate offers an alternative to surgical synovectomy. (orig.) [de

  8. 90Y microsphere therapy: does 90Y PET/CT imaging obviate the need for 90Y Bremsstrahlung SPECT/CT imaging?

    Science.gov (United States)

    Zade, Anand A; Rangarajan, Venkatesh; Purandare, Nilendu C; Shah, Sneha A; Agrawal, Archi R; Kulkarni, Suyash S; Shetty, Nitin

    2013-11-01

    Transarterial radioembolization using Y microspheres is a novel therapeutic option for inoperable hepatic malignancies. As these spheres are radiolucent, real-time assessment of their distribution during the infusion process under fluoroscopic guidance is not possible. Bremsstrahlung radiations arising from 90Y have conventionally been used for imaging its biodistribution. Recent studies have proved that sources of 90Y also emit positrons, which can further be used for PET/computed tomography (CT) imaging. This study aimed to assess the feasibility of 90Y PET/CT imaging in evaluating microsphere distributions and to compare its findings with those of Bremsstrahlung imaging. Thirty-five sessions of 90Y microsphere transarterial radioembolization were performed on 30 patients with hepatic malignancies. 90Y PET/CT imaging was performed within 3 h of therapy. Bremsstrahlung imaging was also performed for each patient. The imaging findings were compared for concordance in the distribution of microspheres. Exact one-to-one correspondence between 90Y PET/CT imaging and 90Y Bremsstrahlung imaging was observed in 97.14% of cases (i.e. in 34/35 cases). Discordance was observed only in one case in which 90Y PET/CT imaging resolved the microsphere uptake in the inferior vena cava tumor thrombus, which was, however, not visualized on Bremsstrahlung imaging. There is good concordance in the imaging findings of 90Y PET/CT and 90Y Bremsstrahlung imaging. 90Y PET/CT imaging scores over the conventionally used Bremsstrahlung imaging in terms of better resolution, ease of technique, and comparable image acquisition time. This makes it a preferred imaging modality for assessment of the distribution of 90Y microspheres.

  9. Glass microspheres covering film: first field evaluations

    International Nuclear Information System (INIS)

    Magnani, G.; Filippi, F.

    2006-01-01

    A trial was carried out to evaluate, in the North-Centre of Italy, the behaviour in field of a new plastic covering film, prepared with the inclusion of empty glass microspheres (Solex). The trial was conducted on tomato (Lycopersicon esculentum L.) and eggplant (Solanum melongena L.). The new film was compared to a covering film with the same optical (diffuse light) and constitutional (co-extruded three layers EVA-WPE) characteristics. Since the first results, the innovative film showed a better behaviour than the control one. It presented light and thermal conditions (lower temperature during the day and slightly higher temperature in the night, compared to the control film) that allowed a better growth and yield than the control film. The growth analysis of tomato showed that plants grown under glass microsphere film had an higher growth rate (dry weight/days) and thickness of leaves compared to the control one. The yield of tomato and eggplant presented an increase in plants cultivated under the innovative film, especially for number and weight of fruits. The commercial quality did not show any differences between the films, except for the flesh hardness of tomato: this could be explained with the fact that the glass microspheres film provides environmental conditions avoiding plant stress during some stages of its cycle [it

  10. Treatment of Unresectable Primary and Metastatic Liver Cancer with Yttrium-90 Microspheres (TheraSphere (registered) ): Assessment of Hepatic Arterial Embolization

    International Nuclear Information System (INIS)

    Sato, Kent; Lewandowski, Robert J.; Bui, James T.; Omary, Reed; Hunter, Russell D.; Kulik, Laura; Mulcahy, Mary; Liu, David; Chrisman, Howard; Resnick, Scott; Nemcek, Albert A.; Vogelzang, Robert; Salem, Riad

    2006-01-01

    In Canada and Europe, yttrium-90 microspheres (TheraSphere); MDS Nordion, Ottawa, Canada) are a primary treatment option for primary and secondary hepatic malignancies. We present data from 30 patients with hepatocellular carcinoma (HCC) and metastatic liver disease treated with TheraSphere from a single academic institution to evaluate the angiographically evident embolization that follows treatment. Seven interventional radiologists from one treatment center compared pretreatment and posttreatment angiograms. The reviewers were blinded to the timing of the studies. The incidence of postembolization syndrome (PES) was determined as well as objective tumor response rates by the World Health Organization (WHO), Response Evaluation Criteria in Solid Tumors (RECIST), and European Association for the Study of the Liver (EASL) criteria. There were 420 independent angiographic observations that were assessed using the chi-squared statistic. The pretreatment and posttreatment angiograms could not be correctly identified on average more than 43% of the time (p = 0.0004). The postprocedure arterial patency rate was 100%. The objective tumor response rates for all patients were 24%, 31%, and 72% for WHO, RECIST, and EASL criteria, respectively. All of the patients tolerated the procedure without complications and were treated on an outpatient basis, and four patients had evidence of PES. This treatment method does not result in macroscopic embolization of the hepatic arteries, thereby maintaining hepatic tissue perfusion. These data support the principle that the favorable response rates reported with TheraSphere are likely due to radiation and microscopic embolization rather than flow-related macroscopic embolization and ischemia

  11. Yttrium-90 microspheres (TheraSphere) treatment of unresectable hepatocellular carcinoma: downstaging to resection, RFA and bridge to transplantation.

    Science.gov (United States)

    Kulik, Laura M; Atassi, Bassel; van Holsbeeck, Lodewijk; Souman, Tameem; Lewandowski, Robert J; Mulcahy, Mary F; Hunter, Russell D; Nemcek, Albert A; Abecassis, Michael M; Haines, Kenneth G; Salem, Riad

    2006-12-01

    To present the clinical data of 35 patients with T3 unresectable hepatocellular carcinoma (HCC) that were treated with (90)Y with the specific intent of downstaging to resection, radiofrequency ablation (RFA) candidate, United Network for Organ Sharing (UNOS) stage T2 or liver transplantation. One hundred fifty patients with unresectable HCC were treated with (90)Y microspheres. Of these, 35 patients were UNOS stage T3 at the time of treatment. Patients were followed for clinical toxicities, alterations in model for end-stage-liver disease (MELD) score, tumor response, downstaging to RFA, resection, transplantation, and survival. Nineteen of 34 patients (56%) were successfully downstaged from T3 to T2 following treatment. 11 of 34 (32%) patients treated were downstaged to target lesions measuring 3.0 cm or less. Twenty-three of 35 (66%) were downstaged to either T2 status, lesion < 3.0 cm (RFA candidate), or resection. Seventeen of 34 (50%) had an objective tumor response by WHO criteria. Eight patients (23%) were successfully downstaged and underwent OLT following treatment. 1, 2, and 3-year survival was 84%, 54%, and 27%, respectively. Median survival by Kaplan-Meier analysis for the entire cohort was 800 days. These data suggest that intra-arterial (90)Y microspheres can be used as a bridge to transplantation, surgical resection, or RFA. (c) 2006 Wiley-Liss, Inc.

  12. XPS analysis of aluminosilicate microspheres bioactivity tested in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Todea, M.; Vanea, E. [Faculty of Physics and Institute of Interdisciplinary Research on Bio-Nano-Sciences, Babes Bolyai University, Cluj-Napoca 400084 (Romania); Bran, S. [University of Medicine and Pharmacy “Iuliu Haţieganu”, Department of Cranio-Maxillofacial Surgery, 400029 Cluj-Napoca (Romania); Berce, P. [Technical University of Cluj-Napoca, Faculty of Machine Building and National Centre of Rapid Prototyping, 400641 Cluj-Napoca (Romania); Simon, S., E-mail: simons@phys.ubbcluj.ro [Faculty of Physics and Institute of Interdisciplinary Research on Bio-Nano-Sciences, Babes Bolyai University, Cluj-Napoca 400084 (Romania)

    2013-04-01

    The study aims to characterize surface properties of aluminosilicate microspheres incorporating yttrium, with potential biomedical applications. Micrometric particles of spherical shape were obtained by spray drying method. The behavior of aluminosilicate microspheres without yttrium and with yttrium was investigated under in vitro conditions, by seven days incubation in simulated body fluid (SBF). The surface elemental composition and the atomic environments on outermost layer of the microspheres, prior to and after incubation in SBF were evaluated by X-ray photoelectron spectroscopy (XPS) in order to investigate their bioactivity. The results were analyzed to underline the effect of yttrium addition on surface properties of the aluminosilicate microspheres and implicitly on the behavior of the samples in simulated body environments.

  13. Preparation of hollow hydroxyapatite microspheres by the conversion of borate glass at near room temperature

    International Nuclear Information System (INIS)

    Yao, Aihua; Ai, Fanrong; Liu, Xin; Wang, Deping; Huang, Wenhai; Xu, Wei

    2010-01-01

    Hollow hydroxyapatite microspheres, consisting of a hollow core and a porous shell, were prepared by converting Li 2 O-CaO-B 2 O 3 glass microspheres in dilute phosphate solution at 37 o C. The results confirmed that Li 2 O-CaO-B 2 O 3 glass was transformed to hydroxyapatite without changing the external shape and dimension of the original glass object. Scanning electron microscopy images showed the shell wall of the microsphere was built from hydroxyapatite particles, and these particles spontaneously align with one another to form a porous sphere with an interior cavity. Increase in phosphate concentration resulted in an increase in the reaction rate, which in turn had an effect on shell wall structure of the hollow hydroxyapatite microsphere. For the Li 2 O-CaO-B 2 O 3 glass microspheres reacted in low-concentration K 2 HPO 4 solution, lower reaction rate and a multilayered microstructure were observed. On the other hand, the glass microspheres reacted in higher phosphate solution converted more rapidly and produced a single hydroxyapatite layer. Furthermore, the mechanism of forming hydroxyapatite hollow microsphere was described.

  14. PREPARATION AND CHARACTERIZATION OF POROUS WALLED HOLLOW GLASS MICROSPHERES

    Energy Technology Data Exchange (ETDEWEB)

    Raszewski, F; Erich Hansen, E; Ray Schumacher, R; David Peeler, D

    2008-04-21

    Porous-walled hollow glass microspheres (PWHGMs) of a modified alkali borosilicate composition have been successfully fabricated by combining the technology of producing hollow glass microspheres (HGMs) with the knowledge associated with porous glasses. HGMs are first formed by a powder glass--flame process, which are then transformed to PWHGMs by heat treatment and subsequent treatment in acid. Pore diameter and pore volume are most influenced by heat treatment temperature. Pore diameter is increased by a factor of 10 when samples are heat treated prior to acid leaching; 100 {angstrom} in non-heat treated samples to 1000 {angstrom} in samples heat treated at 600 C for 8 hours. As heat treatment time is increased from 8 hours to 24 hours there is a slight shift increase in pore diameter and little or no change in pore volume.

  15. Absorbed dose kernel and self-shielding calculations for a novel radiopaque glass microsphere for transarterial radioembolization.

    Science.gov (United States)

    Church, Cody; Mawko, George; Archambault, John Paul; Lewandowski, Robert; Liu, David; Kehoe, Sharon; Boyd, Daniel; Abraham, Robert; Syme, Alasdair

    2018-02-01

    Radiopaque microspheres may provide intraprocedural and postprocedural feedback during transarterial radioembolization (TARE). Furthermore, the potential to use higher resolution x-ray imaging techniques as opposed to nuclear medicine imaging suggests that significant improvements in the accuracy and precision of radiation dosimetry calculations could be realized for this type of therapy. This study investigates the absorbed dose kernel for novel radiopaque microspheres including contributions of both short and long-lived contaminant radionuclides while concurrently quantifying the self-shielding of the glass network. Monte Carlo simulations using EGSnrc were performed to determine the dose kernels for all monoenergetic electron emissions and all beta spectra for radionuclides reported in a neutron activation study of the microspheres. Simulations were benchmarked against an accepted 90 Y dose point kernel. Self-shielding was quantified for the microspheres by simulating an isotropically emitting, uniformly distributed source, in glass and in water. The ratio of the absorbed doses was scored as a function of distance from a microsphere. The absorbed dose kernel for the microspheres was calculated for (a) two bead formulations following (b) two different durations of neutron activation, at (c) various time points following activation. Self-shielding varies with time postremoval from the reactor. At early time points, it is less pronounced due to the higher energies of the emissions. It is on the order of 0.4-2.8% at a radial distance of 5.43 mm with increased size from 10 to 50 μm in diameter during the time that the microspheres would be administered to a patient. At long time points, self-shielding is more pronounced and can reach values in excess of 20% near the end of the range of the emissions. Absorbed dose kernels for 90 Y, 90m Y, 85m Sr, 85 Sr, 87m Sr, 89 Sr, 70 Ga, 72 Ga, and 31 Si are presented and used to determine an overall kernel for the

  16. Initial experience with Yttrium-90 microsphere therapy in patients with end stage metastatic liver disease due to colorectal cancer

    International Nuclear Information System (INIS)

    Poot, M.; Janssen, J.; McKay, E.; Clingan, P.; Morris, D.; Butler, S.P.

    2002-01-01

    Full text: Yttrium-90 labelled microspheres (SIR-Spheres) delivered via the hepatic artery are used in the treatment of non-resectable metastatic liver disease, with the spheres becoming trapped in hepatic tumours. Sixteen patients (9 males, 7 females, 43-80 years) were assessed for therapy. All had failed chemotherapy and had evidence of progressive disease. Extrahepatic disease, ascites and abnormal liver function were first taken into consideration, eliminating 3 patients. The remaining patients underwent a breakthrough scan where Tc99m-MAA was administered intra-hepatically. This scan was used to calculate the level of shunting to the lungs, stomach and bowel and was co-registered with a recent CT scan to confirm MAA uptake corresponded with tumour sites. These breakthrough scans excluded 6 patients, 1 demonstrating high lung activity and 5 not showing focal metastatic accumulation of Tc-99m MAA. Another patient declined. Post-treatment, 4 patients spent 1-2 nights hospitalised for observation with no complications. One patient experienced pain requiring narcotic analgesia and 3 nights in hospital, the other experienced pain, fever, rigours, nausea and vomiting requiring 5 nights hospitalisation. For all patients, liver and bone marrow function was relatively unchanged 1 week post-therapy indicating no acute toxicity. Since receiving therapy, 2 patients survived less than 2 months, dying of disease progression. Two had progressive extrahepatic disease, and the remaining 2 patients, who also received chemotherapy, currently report a good quality of life, although no objective data is currently available to evaluate tumour response. In this selected group of patients, SIR therapy appears to have limited toxicity with yet to be demonstrated efficacy. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  17. Hepatic vein tumor thrombus as a risk factor for excessive pulmonary deposition of microspheres during TheraSphere therapy for unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Fleming, Chad J; Andrews, James C; Wiseman, Gregory A; Gansen, Denise N; Roberts, Lewis R

    2009-11-01

    To evaluate the impact of identifiable hepatic vein tumor thrombus on the ability to safely deliver TheraSphere (yttrium 90-containing glass microspheres) for the treatment of hepatocellular carcinoma (HCC). A retrospective review was performed of 87 patients (71 men, 16 women; mean age, 64.5 years; age range, 25-83 y) referred for TheraSphere therapy for HCC during a 2-year period between April 2005 and May 2007. Evaluation included contrast-enhanced computed tomography or magnetic resonance imaging, selective mesenteric angiography, and radionuclide perfusion scintigraphy to measure the arteriovenous shunting through the tumor. Of the 87 patients, 83 underwent angiography and perfusion scintigraphy; 53 were ultimately treated with 65 glass microsphere infusions. Twelve of 83 were identified as having tumor thrombus in a hepatic vein or extending into the inferior vena cava. The mean lung shunt for the patients with hepatic vein tumor thrombus was 30% (range, 11%-60%), compared with 8.2% (range, 3%-23%) for patients without identifiable tumor thrombus. Two of the 12 patients were treated with reduced doses of glass microspheres, and the remaining 10 were offered alternative therapies. The presence of hepatic vein tumor thrombus is a risk factor for an increased lung shunt that may prohibit delivery of a therapeutic dose of TheraSphere to hepatic tumor.

  18. Decision tree analysis to assess the cost-effectiveness of yttrium microspheres for treatment of hepatic metastases from colorectal cancer

    International Nuclear Information System (INIS)

    Kelley, B.B.; Walker, G.D.; Miles, K.A.

    2002-01-01

    Full text: The aim is to determine the cost-effectiveness of yttrium microsphere treatment of hepatic metastases from colorectal cancer, with and without FDG-PET for detection of extra-hepatic disease. A decision tree was created comparing two strategies for yttrium treatment with chemotherapy, one incorporating PET in addition to CT in the pre-treatment work-up, to a strategy of chemotherapy alone. The sensitivity and specificity of PET and CT were obtained from the Federal Government PET review. Imaging costs were obtained from the Medicare benefits schedule with an additional capital component added for PET (final cost $1200). The cost of yttrium treatment was determined by patient-tracking. Previously published reports indicated a mean gain in life-expectancy from treatment of 0.52 years. Patients with extra-hepatic metastases were assumed to receive no survival benefit. Cost effectiveness was expressed as incremental cost per life-year gained (ICER). Sensitivity analysis determined the effect of prior probability of extra-hepatic disease on cost-savings and cost-effectiveness. The cost of yttrium treatment including angiography, particle perfusion studies and bed-stays, was $10530. A baseline value for prior probability of extra-hepatic disease of 0.35 gave ICERs of $26,378 and $25,271 for the no-PET and PET strategies respectively. The PET strategy was less expensive if the prior probability of extra-hepatic metastases was greater than 0.16 and more cost-effective if above 0.28. Yttrium microsphere treatment is less cost-effective than other interventions for colon cancer but comparable to other accepted health interventions. Incorporating PET into the pre-treatment assessment is likely to save costs and improve cost-effectiveness. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  19. A method and apparatus for the manufacture of glass microspheres adapted to contain a thermonuclear fuel

    International Nuclear Information System (INIS)

    Budrick, R.G.; Nolen, R.L. Jr.; Solomon, D.E.; King, F.T.

    1975-01-01

    The invention relates to the manufacture of glass microspheres. It refers to a method according to which a sintered glass-powder, whose particles are calibrated, is introduced into a blow-pipe adapted to project said glass-powder particles into a heated flue, said sintered glass-powder containing a pore-forming agent adapted to expand the glass particles into microspheres which are collected in a chamber situated abode said flue. The method can be applied to the manufacture of microspheres adapted to contain a thermonuclear fuel [fr

  20. Studies on the preparation and plasma spherodization of yttrium aluminosilicate glass microspheres for their potential application in liver brachytherapy

    Science.gov (United States)

    Sreekumar, K. P.; Saxena, S. K.; Kumar, Yogendra; Thiyagarajan, T. K.; Dash, Ashutosh; Ananthapadmanabhan, P. V.; Venkatesh, Meera

    2010-02-01

    Plasma spheroidization exploits the high temperature and high enthalpy available in the thermal plasma jet to melt irregularly shaped powder particles and quench them to get dense spherical particles. Plasma spheroidization is a versatile process and can be applied to metals, ceramics, alloys and composites to obtain fine spherical powders. Radioactive microspheres incorporated with high energetic beta emitting radioisotopes have been reported to be useful in the palliative treatment of liver cancer. These powders are to be prepared in closer range of near spherical morphology in the size range 20-35 microns. Inactive glass samples were prepared by heating the pre-calculated amount of glass forming ingredients in a recrystallized alumina crucible. The glass was formed by keeping the glass forming ingredients at 1700°C for a period of three hours to form a homogeneous melt. After cooling, the glass was recovered from the crucible by crushing and was subsequently powdered mechanically with the help of mortar and pestle. This powder was used as the feed stock for plasma spheroidization using an indigenously developed 40 kW plasma spray system. Experiments were carried out at various operating parameters. The operating parameters were optimised to get spheroidised particles. The powder was sieved to get the required size range before irradiation.

  1. Studies on the preparation and plasma spherodization of yttrium aluminosilicate glass microspheres for their potential application in liver brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sreekumar, K P; Saxena, S K; Kumar, Yogendra; Thiyagarajan, T K; Dash, Ashutosh; Ananthapadmanabhan, P V; Venkatesh, Meera, E-mail: nair.sreekumar@gmail.co [Laser and Plasma Technology Division, Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Trombay, Mumbai - 400 085 (India)

    2010-02-01

    Plasma spheroidization exploits the high temperature and high enthalpy available in the thermal plasma jet to melt irregularly shaped powder particles and quench them to get dense spherical particles. Plasma spheroidization is a versatile process and can be applied to metals, ceramics, alloys and composites to obtain fine spherical powders. Radioactive microspheres incorporated with high energetic beta emitting radioisotopes have been reported to be useful in the palliative treatment of liver cancer. These powders are to be prepared in closer range of near spherical morphology in the size range 20-35 microns. Inactive glass samples were prepared by heating the pre-calculated amount of glass forming ingredients in a recrystallized alumina crucible. The glass was formed by keeping the glass forming ingredients at 1700{sup 0}C for a period of three hours to form a homogeneous melt. After cooling, the glass was recovered from the crucible by crushing and was subsequently powdered mechanically with the help of mortar and pestle. This powder was used as the feed stock for plasma spheroidization using an indigenously developed 40 kW plasma spray system. Experiments were carried out at various operating parameters. The operating parameters were optimised to get spheroidised particles. The powder was sieved to get the required size range before irradiation.

  2. Studies on the preparation and plasma spherodization of yttrium aluminosilicate glass microspheres for their potential application in liver brachytherapy

    International Nuclear Information System (INIS)

    Sreekumar, K P; Saxena, S K; Kumar, Yogendra; Thiyagarajan, T K; Dash, Ashutosh; Ananthapadmanabhan, P V; Venkatesh, Meera

    2010-01-01

    Plasma spheroidization exploits the high temperature and high enthalpy available in the thermal plasma jet to melt irregularly shaped powder particles and quench them to get dense spherical particles. Plasma spheroidization is a versatile process and can be applied to metals, ceramics, alloys and composites to obtain fine spherical powders. Radioactive microspheres incorporated with high energetic beta emitting radioisotopes have been reported to be useful in the palliative treatment of liver cancer. These powders are to be prepared in closer range of near spherical morphology in the size range 20-35 microns. Inactive glass samples were prepared by heating the pre-calculated amount of glass forming ingredients in a recrystallized alumina crucible. The glass was formed by keeping the glass forming ingredients at 1700 0 C for a period of three hours to form a homogeneous melt. After cooling, the glass was recovered from the crucible by crushing and was subsequently powdered mechanically with the help of mortar and pestle. This powder was used as the feed stock for plasma spheroidization using an indigenously developed 40 kW plasma spray system. Experiments were carried out at various operating parameters. The operating parameters were optimised to get spheroidised particles. The powder was sieved to get the required size range before irradiation.

  3. Preparation and properties of hollow glass microspheres for use in laser fusion experiments

    International Nuclear Information System (INIS)

    Campbell, J.H.; Grens, J.Z.; Poco, J.F.

    1983-01-01

    We review the preparation of high quality, hollow-glass microspheres for use in laser driven fusion experiments at LLNL. The primary focus of this paper is on the liquid-droplet method for making glass spheres, which has been in use at LLNL for over six years. We have combined the results from previous studies with our current results to present a detailed description of the preparation and the composition and physical properties of the glass microspheres. We also present a mathematical model that simulates the microsphere formation process. Examples are given of the application of the model to study the effects of various process parameters

  4. Preparation and properties of hollow glass microspheres for use in laser fusion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.H.; Grens, J.Z.; Poco, J.F.

    1983-11-01

    We review the preparation of high quality, hollow-glass microspheres for use in laser driven fusion experiments at LLNL. The primary focus of this paper is on the liquid-droplet method for making glass spheres, which has been in use at LLNL for over six years. We have combined the results from previous studies with our current results to present a detailed description of the preparation and the composition and physical properties of the glass microspheres. We also present a mathematical model that simulates the microsphere formation process. Examples are given of the application of the model to study the effects of various process parameters.

  5. First experience of hepatic radioembolization using microspheres labelled with yttrium-90 (TheraSphere): practical aspects concerning its implementation

    International Nuclear Information System (INIS)

    Garin, Etienne; Bourguet, Patrick; Rolland, Yan; Boucher, Eveline; Ardisson, Valerie; Laffont, Sophie; Boudjema, Karim; Raoul, Jean-Luc

    2010-01-01

    We report a first experience involving the use of 90 Y radiolabelled microspheres (TheraSphere) for the treatment of mainly primary hepatic tumours. Treatment using TheraSphere microspheres was planned in 15 patients (13 with hepatocellular carcinoma, 2 with neuroendocrine tumour metastases). The treatment was preceded by a first angiography aimed at embolizing the vascularizing arterial branches of other structures outside the liver and evaluating the percentage of pulmonary shunt by scintiscanning after perfusion with 99m Tc-MAA. The objective of the treatment carried out during a second angiography was to deliver a dose of 120±20 Gy (mean±SD) to the target hepatic volume. Technical difficulties were encountered in embolizing gastroduodenal or gastric branches in two patients and in one patient these led to cancellation of the treatment. A total of 14 patients were treated with an average activity of 3.18 GBq. In one patient, the injection was defective (stagnation of microspheres at the outlet of the catheter). SPECT/CT acquisitions provided important information in four patients (visualization of the gallbladder in three; visualization of the stomach in one, leading to a new coiling). The average exposure of the nuclear medicine physician carrying out the injections was 64±80μSv at the fingers. A partial response was seen in six patients, stabilization in five and progression in three. One patient presented with a gastric ulcer and two showed an increase in their hepatocellular insufficiency. Although sometimes technically difficult, the use of TheraSphere microspheres is a worthwhile therapeutic approach because of the low level exposure of operators and the encouraging rate of response or stabilization. The use of SPECT/CT contributes greatly to helping therapeutic planning, especially in the learning curve or when the angiographic procedure is difficult. (orig.)

  6. First experience of hepatic radioembolization using microspheres labelled with yttrium-90 (TheraSphere): practical aspects concerning its implementation.

    Science.gov (United States)

    Garin, Etienne; Rolland, Yan; Boucher, Eveline; Ardisson, Valérie; Laffont, Sophie; Boudjema, Karim; Bourguet, Patrick; Raoul, Jean-Luc

    2010-03-01

    We report a first experience involving the use of (90)Y radiolabelled microspheres (TheraSphere) for the treatment of mainly primary hepatic tumours. Treatment using TheraSphere microspheres was planned in 15 patients (13 with hepatocellular carcinoma, 2 with neuroendocrine tumour metastases). The treatment was preceded by a first angiography aimed at embolizing the vascularizing arterial branches of other structures outside the liver and evaluating the percentage of pulmonary shunt by scintiscanning after perfusion with (99m)Tc-MAA. The objective of the treatment carried out during a second angiography was to deliver a dose of 120+/-20 Gy (mean+/-SD) to the target hepatic volume. Technical difficulties were encountered in embolizing gastroduodenal or gastric branches in two patients and in one patient these led to cancellation of the treatment. A total of 14 patients were treated with an average activity of 3.18 GBq. In one patient, the injection was defective (stagnation of microspheres at the outlet of the catheter). SPECT/CT acquisitions provided important information in four patients (visualization of the gallbladder in three; visualization of the stomach in one, leading to a new coiling). The average exposure of the nuclear medicine physician carrying out the injections was 64+/-80 microSv at the fingers. A partial response was seen in six patients, stabilization in five and progression in three. One patient presented with a gastric ulcer and two showed an increase in their hepatocellular insufficiency. Although sometimes technically difficult, the use of TheraSphere microspheres is a worthwhile therapeutic approach because of the low level exposure of operators and the encouraging rate of response or stabilization. The use of SPECT/CT contributes greatly to helping therapeutic planning, especially in the learning curve or when the angiographic procedure is difficult.

  7. First experience of hepatic radioembolization using microspheres labelled with yttrium-90 (TheraSphere): practical aspects concerning its implementation

    Energy Technology Data Exchange (ETDEWEB)

    Garin, Etienne; Bourguet, Patrick [Comprehensive Cancer Center Eugene Marquis, Department of Nuclear Medicine, Rennes (France); University of Rennes 1, European University of Brittany/EA MDC, Rennes (France); Rolland, Yan [Comprehensive Cancer Center Eugene Marquis, Department of Medical Imaging, Rennes (France); Boucher, Eveline [Comprehensive Cancer Center Eugene Marquis, Department of Medical Oncology, Rennes (France); Ardisson, Valerie; Laffont, Sophie [Comprehensive Cancer Center Eugene Marquis, Department of Nuclear Medicine, Rennes (France); Boudjema, Karim [University of Rennes 1, European University of Brittany/EA MDC, Rennes (France); CHU Pontchaillou, Department of Digestive Surgery, Rennes (France); Raoul, Jean-Luc [University of Rennes 1, European University of Brittany/EA MDC, Rennes (France); Comprehensive Cancer Center Eugene Marquis, Department of Medical Oncology, Rennes (France)

    2010-03-15

    We report a first experience involving the use of {sup 90}Y radiolabelled microspheres (TheraSphere) for the treatment of mainly primary hepatic tumours. Treatment using TheraSphere microspheres was planned in 15 patients (13 with hepatocellular carcinoma, 2 with neuroendocrine tumour metastases). The treatment was preceded by a first angiography aimed at embolizing the vascularizing arterial branches of other structures outside the liver and evaluating the percentage of pulmonary shunt by scintiscanning after perfusion with {sup 99m}Tc-MAA. The objective of the treatment carried out during a second angiography was to deliver a dose of 120{+-}20 Gy (mean{+-}SD) to the target hepatic volume. Technical difficulties were encountered in embolizing gastroduodenal or gastric branches in two patients and in one patient these led to cancellation of the treatment. A total of 14 patients were treated with an average activity of 3.18 GBq. In one patient, the injection was defective (stagnation of microspheres at the outlet of the catheter). SPECT/CT acquisitions provided important information in four patients (visualization of the gallbladder in three; visualization of the stomach in one, leading to a new coiling). The average exposure of the nuclear medicine physician carrying out the injections was 64{+-}80{mu}Sv at the fingers. A partial response was seen in six patients, stabilization in five and progression in three. One patient presented with a gastric ulcer and two showed an increase in their hepatocellular insufficiency. Although sometimes technically difficult, the use of TheraSphere microspheres is a worthwhile therapeutic approach because of the low level exposure of operators and the encouraging rate of response or stabilization. The use of SPECT/CT contributes greatly to helping therapeutic planning, especially in the learning curve or when the angiographic procedure is difficult. (orig.)

  8. Quantitative and qualitative assessment of Yttrium-90 PET/CT imaging.

    Directory of Open Access Journals (Sweden)

    Ali Asgar Attarwala

    Full Text Available Yttrium-90 is known to have a low positron emission decay of 32 ppm that may allow for personalized dosimetry of liver cancer therapy with (90Y labeled microspheres. The aim of this work was to image and quantify (90Y so that accurate predictions of the absorbed dose can be made. The measurements were performed within the QUEST study (University of Sydney, and Sirtex Medical, Australia. A NEMA IEC body phantom containing 6 fillable spheres (10-37 mm ∅ was used to measure the 90Y distribution with a Biograph mCT PET/CT (Siemens, Erlangen, Germany with time-of-flight (TOF acquisition. A sphere to background ratio of 8:1, with a total (90Y activity of 3 GBq was used. Measurements were performed for one week (0, 3, 5 and 7 d. he acquisition protocol consisted of 30 min-2 bed positions and 120 min-single bed position. Images were reconstructed with 3D ordered subset expectation maximization (OSEM and point spread function (PSF for iteration numbers of 1-12 with 21 (TOF and 24 (non-TOF subsets and CT based attenuation and scatter correction. Convergence of algorithms and activity recovery was assessed based on regions-of-interest (ROI analysis of the background (100 voxels, spheres (4 voxels and the central low density insert (25 voxels. For the largest sphere, the recovery coefficient (RC values for the 30 min -2-bed position, 30 min-single bed and 120 min-single bed were 1.12 ± 0.20, 1.14 ± 0.13, 0.97 ± 0.07 respectively. For the smaller diameter spheres, the PSF algorithm with TOF and single bed acquisition provided a comparatively better activity recovery. Quantification of Y-90 using Biograph mCT PET/CT is possible with a reasonable accuracy, the limitations being the size of the lesion and the activity concentration present. At this stage, based on our study, it seems advantageous to use different protocols depending on the size of the lesion.

  9. Boosted selective internal radiation therapy with {sup 90}Y-loaded glass microspheres (B-SIRT) for hepatocellular carcinoma patients: a new personalized promising concept

    Energy Technology Data Exchange (ETDEWEB)

    Garin, E.; Lenoir, L. [Comprehensive Cancer Center, Institute Eugene Marquis, Department of Nuclear Medicine, CS 44229, Rennes (France); University of Rennes 1, Rennes (France); INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Edeline, J. [University of Rennes 1, Rennes (France); Comprehensive Cancer Center, Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France); Laffont, S. [Comprehensive Cancer Center, Institute Eugene Marquis, Department of Nuclear Medicine, CS 44229, Rennes (France); Mesbah, H.; Poree, P. [Comprehensive Cancer Center, Institute Eugene Marquis, Department of Medical Informatics, CS 44229, Rennes (France); Sulpice, L. [INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Centre Hospitalier Universitaire Pontchaillou, Department of Digestive Surgery, Rennes (France); Boudjema, K. [University of Rennes 1, Rennes (France); INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Centre Hospitalier Universitaire Pontchaillou, Department of Digestive Surgery, Rennes (France); Mesbah, M. [University of Pierre et Marie Curie, Paris (France); Guillygomarc' h, A. [Centre Hospitalier Universitaire Pontchaillou, Department of Hepatology, Rennes (France); Quehen, E. [Centre Hospitalier Universitaire Pontchaillou, Department of Radiology, Rennes (France); Pracht, M. [Comprehensive Cancer Center, Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France); Raoul, J.L. [Comprehensive Cancer Center, Institute Paoli Calmette, Department of Medical Oncology, Marseille (France); Clement, B. [INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Rolland, Y. [Comprehensive Cancer Center, Institute Eugene Marquis, Department of Medical Imaging, CS 44229, Rennes (France); Boucher, E. [INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Comprehensive Cancer Center, Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France)

    2013-07-15

    To evaluate the impact of dosimetry based on MAA SPECT/CT for the prediction of response, toxicity and survival, and for treatment planning in patients with hepatocellular carcinoma (HCC) treated with {sup 90}Y-loaded glass microspheres (TheraSphere registered). TheraSphere registered was administered to 71 patients with inoperable HCC. MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), healthy injected liver dose (HILD), and total injected liver dose. Response was evaluated at 3 months using EASL criteria. Time to progression (TTP) and overall survival (OS) were evaluated using the Kaplan-Meier method. Factors potentially associated with liver toxicity were combined to construct a liver toxicity score (LTS). The response rate was 78.8 %. Median TD were 342 Gy for responding lesions and 191 Gy for nonresponding lesions (p < 0.001). With a threshold TD of 205 Gy, MAA SPECT/CT predicted response with a sensitivity of 100 % and overall accuracy of 90 %. Based on TD and HILD, 17 patients underwent treatment intensification resulting in a good response rate (76.4 %), without increased grade III liver toxicity. The median TTP and OS were 5.5 months (2-9.5 months) and 11.5 months (2-31 months), respectively, in patients with TD <205 Gy and 13 months (10-16 months) and 23.2 months (17.5-28.5 months), respectively, in those with TD >205 Gy (p = 0.0015 and not significant). Among patients with portal vein thrombosis (PVT) (n = 33), the median TTP and OS were 4.5 months (2-7 months) and 5 months (2-8 months), respectively, in patients with TD <205 Gy and 10 months (6-15.2 months) and 21.5 months (12-28.5 months), respectively, in those with TD >205 Gy (p = 0.039 and 0.005). The median OS was 24.5 months (18-28.5 months) in PVT patients with TD >205 Gy and good PVT targeting on MAA SPECT/CT. The LTS was able to detect severe liver toxicity (n = 6) with a sensitivity of 83 % and overall accuracy of 97 %. Dosimetry based on MAA SPECT/CT was

  10. Development of phosphate glass microspheres containing holmium for selective internal radiotherapy

    International Nuclear Information System (INIS)

    Barros Filho, Eraldo Cordeiro

    2016-01-01

    The selective internal radiotherapy is an alternative for some kinds of cancer as the hepatocellular carcinoma (HCC) or primary liver cancer treatment. In this treatment, glass or polymer microspheres containing radionuclides inside their structure are introduced in the liver through hepatic artery and trapped at the arterioles that feed the tumor. In this work, the development of phosphate glasses containing holmium for production of microspheres and their application in Brazil are proposed. The developed glasses presented suitable chemical durability, density of 2,7(3) g/cm 3 , high thermal stability and the impurities contained therein do not preclude the treatment. The microspheres were produced by the flame method and the gravitational fall method, and were characterized by means of several techniques to evaluate shape, average particle size, activity and biocompatibility suitable for selective internal radiotherapy. Based in the main results, the submission to in vivo tests is proposed. (author)

  11. Calorimetric investigation of an yttrium-dysprosium spin glass

    International Nuclear Information System (INIS)

    Wenger, L.E.

    1978-01-01

    In an effort to compare the spin glass characteristics of yttrium--rare earth alloys with those of the noble-metal spin glasses, the susceptibility and heat capacity of Y/sub 0.98/Dy/sub 0.02/ have been measured in the temperature range 2.5--40 K. The low-field ac susceptibility measurement shows the characteristic cusp-like peak at 7.64 K. The magnetic specific heat of the same sample shows a peak at 7.0 K and may be qualitatively described as a semi-cusp. The magnetic entropy change from absolute zero to 7 K is approximately 0.52 of cR ln(2J+1). These results are qualitatively different than previous calorimetric results on the archetypal spin glasses, AuFe and CuMn, where rounded maxima are observed at temperatures above the spin glass transition temperatures

  12. Study on stability of labeled yttrium-90 with lipiodol by chemical extraction for liver cancer

    International Nuclear Information System (INIS)

    Mu, P.Y.; Jiang, X.L.; Chen, J.; Zhu, Y.J.

    2005-01-01

    Liver cancer, particularly hepatocellular carcinoma, is one of the most common malignant diseases in many developed and developing countries. It is also one of the most common diseases endangering the people's lives and health heavily. Surgery is very effective in early-stage patients. Unfortunately, there is less than 10% of the patients with hepatocellular carcinoma fitting for surgical therapy. Instead of surgical therapy, other methods are considered for patients in whom surgery may not work well. Systemic administration of chemotherapeutic agents is not often considered in liver cancer patients, due to discouraging result and adverse side effects. Also, hepatocellular carcinoma is not keen on usual radioactive therapy. However, method of inner interventional radioactive nuclide is a potential way to cure liver tumors. Hepatocellular carcinoma would be cured with inner interventional radioactive nuclide, which is a hot topic in experimental research on hepatocellular carcinoma at home and abroad. The purpose of the study is to label Yttrium-90 with lipiodol by means of the chemical extraction method and research the stability of labeled Yttrium-90 ( 90 Y-P204-Lipiodol) in serum of a newly-born cattle and human's blood. We chose to label steady yttrium with lipiodol, because radioactive yttrium has great nuclear character for liver cancer, yttrium-90 can eradiate pure β radial, and it's half time is 64 hours. Average energy of it is 0.93 Mev, the highest energy is 2.27 Mev. Yttrium-90 can be labeled with lipiodol by means of the chemical extraction method, which is mature in chemical techniques, combined with method of radioactive nuclide labeled in. nuclear medicine. At first, yttrium-90 is extracted in certain condition(pH, temperature, whisk time, whisk frequency, etc ) after adding yttrium-90 solution. We use some distilled water to balance the labeled organic phase twice, and test the stability of labeled yttrium-90 in serum of a newly-born cattle and

  13. Y-90 microshperes in the treatment of unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Al-Kalbani, Abdullah; Kamel, Yasser

    2008-04-01

    A small percentage of patients with hepatocellular carcinoma (HCC) are candidates for curative treatment in form of resection or transplantation. There are different treatment options for unresectable HCC-like local ablative therapies and recently systemic therapy with Sorafenib. All of these have variable response rate and had been proven to improve survival. In the last few years, there is a growing interest in TheraSphere radioembolization. It consists of yttrium90 (Y-90) embedded into nonbiodegradable glass microspheres. It is selectively administered by intraarterial hepatic injection giving high doses of radiation to the tumor and sparing the liver parenchyma. It has been shown to improve survival and used as a bridge to transplantation and to downstage tumors for resection. Therasphere seems to have favorable safety profile and has been used in patients with portal vein thrombosis with successful outcome.

  14. Development of activity standard for 90Y microspheres

    CSIR Research Space (South Africa)

    Mo, L

    2005-08-01

    Full Text Available 90Y is a therapeutic radiopharmaceuticals used in the treatment of liver cancer following implantation via a catheter in the hepatic artery, 90Y microspheres are embolised in the microvasculature of liver cancer where they irradiate the tumour by a...

  15. Upconversion channels in Er3+ ZBLALiP fluoride glass microspheres

    NARCIS (Netherlands)

    O'Shea, D. G.; Ward, J. M.; Shortt, B. J.; Mortier, M.; Feron, P.; Chormaic, S. Nic

    We present results on the realization of a multicolour microspherical glass light source fabricated from the erbium doped fluoride glass ZBLALiP. Whispering gallery mode lasing and upconversion processes give rise to laser and fluorescent emissions at multiple wavelengths from the ultraviolet to the

  16. Abscopal Effects and Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Ghodadra, Anish; Bhatt, Sumantha [University Pittsburgh School of Medicine, Department of Radiology (United States); Camacho, Juan C. [Emory University School of Medicine, Department of Radiology and Imaging Sciences (United States); Kim, Hyun S., E-mail: kevin.kim@yale.edu [University Pittsburgh School of Medicine, Department of Radiology (United States)

    2016-07-15

    We present the case of an 80-year-old male with squamous cell carcinoma with bilobar hepatic metastases who underwent targeted Yttrium-90 radioembolization of the right hepatic lobe lesion. Subsequently, there was complete regression of the nontargeted, left hepatic lobe lesion. This may represent the first ever reported abscopal effect in radioembolization. The abscopal effect refers to the phenomenon of tumor response in nontargeted sites after targeted radiotherapy. In this article, we briefly review the immune-mediated mechanisms responsible for the abscopal effect.

  17. Booted selective internal radiation therapy (B-SIRT) using 90Y-loaded glass microspheres induces prolonged overall survival for PVT patients

    International Nuclear Information System (INIS)

    Garin, E.; Lenoir, L.; Edeline, J.; Laffont, S.; Mesbah, H.; Poree, P.; Boucher, E.; Rolland, Y.

    2015-01-01

    Full text of publication follows. Goal: evaluation of the response rate and survival of hepatocellular carcinoma PVT patients treated with Therasphere using the boost concept. Material and methods: Therasphere was administered in 40 PVT hepatocellular carcinoma patients (main = 11, lobar = 23, segmental = 6). MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), the healthy injected liver dose (HLD) and the injected liver dose (LD). Response was evaluated at 3 months using EASL criterion. OS was evaluated using Kaplan and Meyer tests. Results: Mean 90 Y-loaded microspheres injected activity was 3.1 ± 1.5 GBq. Mean LD was 143 ± 49 Gy. Median TD was 316 Gy for responding lesions versus 133 Gy for non responding lesion (p<0.0001). With a threshold TD of 205 Gy, MAA-SPECT/CT was predictive of response with a sensibility of 100%, and an overall accuracy of 90% (0FN, 4FP). Knowing the TD and the HLD, 40% of the patients received an intensification of the treatment (increase of the injected activity with the goal to achieve a TD> 205 Gy with a LD > 150 Gy and a HLD<120 Gy) with a good response rate (81%) and without increased liver grade III toxicity (6.2% as against 12.5% in the non boosted patients, ns). 6 patients were put aside, 5 received a lobar hepatectomy. Median OS was 18.2 months [12-27]. It was 4 m [12-27] for patients with a TD < 205 Gy versus 21.5 m [12-28.5] for patients with a TD > 205 Gy. OS was 12 m [3-∞] for patients with main PVT versus 21.5 m [12-28.7] for patients segmental or lobar PVT (ns). Finally Os was 23.2 m for patients with a TD > 205 Gy and a good PVT targeting (n = 34). Conclusion: boosted selective internal radiation therapy using 90 Y-loaded glass microspheres induces prolonged overall survival for PVT patients without increasing liver toxicity. (authors)

  18. SU-C-204-01: A Dosimetric Investigation Into the Effects of Yttrium-90 Radioembolization On the GI Tract: In-Vivo and Histological Analysis in An Animal Model

    Energy Technology Data Exchange (ETDEWEB)

    Pasciak, A [University of Tennessee Medical Center, Knoxville, TN (United States); The University of Tennessee Graduate School of Medicine, Knoxville, TN (United States); Nodit, L; Bourgeois, A; Bradley, Y [The University of Tennessee Graduate School of Medicine, Knoxville, TN (United States); Paxton, B [Duke university medical center, Durham, NC (United States); Arepally, A [Vanderbilt University Medical Center, Nashville, TN (United States)

    2016-06-15

    Purpose: In Yttrium-90 (90Y) radioembolization, non-target embolization (NTE) to the stomach or small bowel can result in ulceration, a rare but difficult to manage clinical complication. However, dosimetric thresholds for toxicity to these tissues from radioembolization have never been evaluated in a controlled setting. We performed an analysis of the effect of 90Y radioembolization in a porcine model at different absorbed-dose endpoints. Methods: Under approval of the University of Tennessee IACUC, 6 female pigs were included in this study. Animals underwent transfemoral angiography and infusion of calibrated dosages of 90Y resin microspheres into arteries supplying part of the gastric wall. A 99mTc-MAA simulation study was performed first to determine perfused tissue volume for treatment planning along with contrast-enhanced CT. The pigs were monitored for side effects for 9 weeks, after which time they were euthanized and their upper gastrointestinal tracts were harvested for analysis. Results: 90Y radioembolization was infused resulting in average absorbed doses of between 35.5 and 91.9 Gy to the gastric wall. No animal exhibited any signs of pain or gastrointestinal distress through the duration of the study. Excised tissue showed 1–2 small (<3.0 cm2) healed or healing superficial gastric lesions in 5 out of 6 animals. Histologic analysis demonstrated that lesion location was superficial to areas of abnormally high microsphere deposition. An analysis of microsphere deposition patterns within the gastric wall indicated a high preference for submucosal deposition. Dosimetric evaluation at the luminal mucosa performed based on microsphere deposition patterns confirmed that 90Y dosimetry techniques conventionally used in hepatic dosimetry provide a reasonable estimate of absorbed dose. Conclusion: The upper gastrointestinal tract may be less sensitive to 90Y radioembolization than previously thought. Lack of charged-particle equilibrium at the luminal mucosa

  19. Determination of strontium-90 from direct separation of yttrium-90 by solid phase extraction using DGA Resin for seawater monitoring.

    Science.gov (United States)

    Tazoe, Hirofumi; Obata, Hajime; Yamagata, Takeyasu; Karube, Zin'ichi; Nagai, Hisao; Yamada, Masatoshi

    2016-05-15

    It is important for public safety to monitor strontium-90 in aquatic environments in the vicinity of nuclear related facilities. Strontium-90 concentrations in seawater exceeding the background level have been observed in accidents of nuclear facilities. However, the analytical procedure for measuring strontium-90 in seawater is highly demanding. Here we show a simple and high throughput analytical technique for the determination of strontium-90 in seawater samples using a direct yttrium-90 separation. The DGA Resin is used to determine the abundance of strontium-90 by detecting yttrium-90 decay (beta-emission) in secular equilibrium. The DGA Resin can selectively collect yttrium-90 and remove naturally occurring radionuclides such as (40)K, (210)Pb, (214)Bi, (238)U, and (232)Th and anthropogenic radionuclides such as (140)Ba, and (140)La. Through a sample separation procedure, a high chemical yield of yttrium-90 was achieved at 95.5±2.3%. The result of IAEA-443 certified seawater analysis (107.7±3.4 mBq kg(-1)) was in good agreement with the certified value (110±5 mBq kg(-1)). By developed method, we can finish analyzing 8 samples per day after achieving secular equilibrium, which is a reasonably fast throughput in actual seawater monitoring. By processing 3 L of seawater sample and applying a counting time of 20 h, minimum detectable activity can be as low as 1.5 mBq kg(-1), which could be applied to monitoring for the contaminated marine environment. Reproducibility was found to be 3.4% according to 10 independent analyses of natural seawater samples from the vicinity of the Fukushima Daiichi Nuclear Power Plant in September 2013. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Utility of Quantitative Tc-MAA SPECT/CT for yttrium-Labelled Microsphere Treatment Planning: Calculating Vascularized Hepatic Volume and Dosimetric Approach.

    Science.gov (United States)

    Garin, Etienne; Rolland, Yan; Lenoir, Laurence; Pracht, Marc; Mesbah, Habiba; Porée, Philippe; Laffont, Sophie; Clement, Bruno; Raoul, Jean-Luc; Boucher, Eveline

    2011-01-01

    Objectives. The aim of this study was to assess the effectiveness of SPECT/CT for volume measurements and to report a case illustrating the major impact of SPECT/CT in calculating the vascularized liver volume and dosimetry prior to injecting radiolabelled yttrium-90 microspheres (Therasphere). Materials and Methods. This was a phantom study, involving volume measurements carried out by two operators using SPECT and SPECT/CT images. The percentage of error for each method was calculated, and interobserver reproducibility was evaluated. A treatment using Therasphere was planned in a patient with three hepatic arteries, and the quantitative analysis of SPECT/CT for this patient is provided. Results. SPECT/CT volume measurements proved to be accurate (mean error Therasphere used. Conclusions. MAA SPECT/CT is accurate for vascularized liver volume measurements, providing a valuable contribution to the therapeutic planning of patients with complex hepatic vascularization.

  1. Lack of rise in serum prolactin following yttrium-90 interstitial irradiation for acromegaly

    International Nuclear Information System (INIS)

    Clark, A.J.L.; Chahal, P.; Mashiter, K.; Joplin, G.F.

    1983-01-01

    The authors have investigated the possibility that the increase in serum PRL levels observed in patients with acromegaly treated with external irradiation could be due to damage to the hypothalamus or portal vessels, by comparing the effects of yttrium-90 interstitial irradiation, which is highly localised and does not normally extend to the hypothalamus, in a similar series of patients. These results are consistent with the hypothesis; a less likely explanation is that an overgrowth of radio-resistant PRL-secreting tumour cells is occurring after external irradiation, but not after yttrium-90 implantation. (author)

  2. Lack of rise in serum prolactin following yttrium-90 interstitial irradiation for acromegaly

    Energy Technology Data Exchange (ETDEWEB)

    Clark, A.J.L.; Chahal, P.; Mashiter, K.; Joplin, G.F. (Royal Postgraduate Medical School, London (UK))

    1983-11-01

    The authors have investigated the possibility that the increase in serum PRL levels observed in patients with acromegaly treated with external irradiation could be due to damage to the hypothalamus or portal vessels, by comparing the effects of yttrium-90 interstitial irradiation, which is highly localised and does not normally extend to the hypothalamus, in a similar series of patients. These results are consistent with the hypothesis; a less likely explanation is that an overgrowth of radio-resistant PRL-secreting tumour cells is occurring after external irradiation, but not after yttrium-90 implantation.

  3. Investigation of emulsified, acid and acid-alkali catalyzed mesoporous bioactive glass microspheres for bone regeneration and drug delivery

    Energy Technology Data Exchange (ETDEWEB)

    Miao, Guohou [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 China (China); National Engineering Research Center for Tissue Restoration and Reconstruction, Guangzhou 510006 China (China); Guangdong Province Key Laboratory of Biomedical Engineering, South China University of Technology, Guangzhou 510006 China (China); Chen, Xiaofeng, E-mail: chenxf@scut.edu.cn [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 China (China); National Engineering Research Center for Tissue Restoration and Reconstruction, Guangzhou 510006 China (China); Guangdong Province Key Laboratory of Biomedical Engineering, South China University of Technology, Guangzhou 510006 China (China); Dong, Hua [National Engineering Research Center for Tissue Restoration and Reconstruction, Guangzhou 510006 China (China); Guangdong Province Key Laboratory of Biomedical Engineering, South China University of Technology, Guangzhou 510006 China (China); School of Biological Science and Engineering, South China University of Technology, Guangzhou 510006 (China); Fang, Liming; Mao, Cong; Li, Yuli; Li, Zhengmao; Hu, Qing [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 China (China); National Engineering Research Center for Tissue Restoration and Reconstruction, Guangzhou 510006 China (China); Guangdong Province Key Laboratory of Biomedical Engineering, South China University of Technology, Guangzhou 510006 China (China)

    2013-10-15

    Acid-catalyzed mesoporous bioactive glass microspheres (MBGMs-A) and acid-alkali co-catalyzed mesoporous bioactive glass microspheres (MBGMs-B) were successfully synthesized via combination of sol-gel and water-in-oil (W/O) micro-emulsion methods. The structural, morphological and textural properties of mesoporous bioactive glass microspheres (MBGMs) were characterized by various techniques. Results show that both MBGMs-A and MBGMs-B exhibit regularly spherical shape but with different internal porous structures, i.e., a dense microstructure for MBGMs-A and internally porous structure for MBGMs-B. {sup 29}Si NMR data reveal that MGBMs have low polymerization degree of silica network. The in vitro bioactivity tests indicate that the apatite formation rate of MBGMs-B was faster than that of MBGMs-A after soaking in simulated body fluid (SBF) solution. Furthermore, the two kinds of MBGMs have similar storage capacity of alendronate (AL), and the release behaviors of AL could be controlled due to their unique porous structure. In conclusion, the microspheres are shown to be promising candidates as bone-related drug carriers and filling materials of composite scaffold for bone repair. - Graphical abstract: The morphologies and microstructures of acid-catalyzed mesoporous bioactive glass microspheres (MBGMs-A) and acid-alkali co-catalyzed mesoporous bioactive glass microspheres (MBGMs-B) were observed by scanning electron microscope and transmission electron microscope. MBGMs-A exhibits a dense structure and a porous can be observed in MBGMs-B. The microspheres have a quick inducing-apatite formation ability and show a sustained release of alendronate (AL). Highlights: • A rapid method was reported to prepare mesoporous bioactive glass microspheres. • The addition of ammonia significantly shortens the preparation time. • Acid and acid-alkali co-catalyzed microspheres were studied for the first time. • The materials exhibited excellent in vitro bioactivity and

  4. Preoperative Y-90 microsphere selective internal radiation treatment for tumor downsizing and future liver remnant recruitment: a novel approach to improving the safety of major hepatic resections.

    Science.gov (United States)

    Gulec, Seza A; Pennington, Kenneth; Hall, Michael; Fong, Yuman

    2009-01-08

    Extended liver resections are being performed more liberally than ever. The extent of resection of liver metastases, however, is restricted by the volume of the future liver remnant (FLR). An intervention that would both accomplish tumor control and induce compensatory hypertrophy, with good patient tolerability, could improve clinical outcomes. A 53-year-old woman with a history of cervical cancer presented with a large liver mass. Subsequent biopsy indicated poorly differentiated carcinoma with necrosis suggestive of squamous cell origin. A decision was made to proceed with pre-operative chemotherapy and Y-90 microsphere SIRT with the intent to obtain systemic control over the disease, downsize the hepatic lesion, and improve the FLR. A surgical exploration was performed six months after the first SIRT (three months after the second). There was no extrahepatic disease. The tumor was found to be significantly decreased in size with central and peripheral scarring. The left lobe was satisfactorily hypertrophied. A formal right hepatic lobectomy was performed with macroscopic negative margins. Selective internal radiation treatment (SIRT) with yttrium-90 (Y-90) microspheres has emerged as an effective liver-directed therapy with a favorable therapeutic ratio. We present this case report to suggest that the portal vein radiation dose can be substantially increased with the intent of inducing portal/periportal fibrosis. Such a therapeutic manipulation in lobar Y-90 microsphere treatment could accomplish the end points of PVE with avoidance of the concern regarding tumor progression.

  5. Potential of Hollow Glass Microsphere as Cement Replacement for Lightweight Foam Concrete on Thermal Insulation Performance

    Directory of Open Access Journals (Sweden)

    Shahidan Shahiron

    2017-01-01

    Full Text Available Global warming can be defined as a gradual increase in the overall temperature of the earth’s atmosphere. A lot of research work has been carried out to reduce that heat inside the residence such as the used of low density products which can reduce the self-weight, foundation size and construction costs. Foamed concrete it possesses high flow ability, low self-weight, minimal consumption of aggregate, controlled low strength and excellent thermal insulation properties. This study investigate the characteristics of lightweight foamed concrete where Portland cement (OPC was replaced by hollow glass microsphere (HGMs at 0%, 3%, 6%, 9% by weight. The density of wet concrete is 1000 kg/m3 were tested with a ratio of 0.55 for all water binder mixture. Lightweight foamed concrete hollow glass microsphere (HGMs produced were cured by air curing and water curing in tank for 7, 14 and 28 days. A total of 52 concrete cubes of size 100mm × 100mm × 100mm and 215mm × 102.5mm × 65mm were produced. Furthermore, Scanning Electron Microscope (SEM and X-ray fluorescence (XRF were carried out to study the chemical composition and physical properties of crystalline materials in hollow glass microspheres. The experiments involved in this study are compression strength, water absorption test, density and thermal insulation test. The results show that the compressive strength of foamed concrete has reached the highest in 3% of hollow glass microsphere with less water absorption and less of thermal insulation. As a conclusion, the quantity of hollow glass microsphere plays an important role in determining the strength and water absorption and also thermal insulation in foamed concrete and 3% hollow glass microspheres as a replacement for Portland cement (OPC showed an optimum value in this study as it presents a significant effect than other percentage.

  6. Multi institutional quantitative phantom study of yttrium-90 PET in PET/MRI: the MR-QUEST study.

    Science.gov (United States)

    Maughan, Nichole M; Eldib, Mootaz; Faul, David; Conti, Maurizio; Elschot, Mattijs; Knešaurek, Karin; Leek, Francesca; Townsend, David; DiFilippo, Frank P; Jackson, Kimberly; Nekolla, Stephan G; Lukas, Mathias; Tapner, Michael; Parikh, Parag J; Laforest, Richard

    2018-04-04

    Yttrium-90 ( 90 Y) radioembolization involves the intra-arterial delivery of radioactive microspheres to treat hepatic malignancies. Though this therapy involves careful pre-treatment planning and imaging, little is known about the precise location of the microspheres once they are administered. Recently, there has been growing interest post-radioembolization imaging using positron-emission tomography (PET) for quantitative dosimetry and identifying lesions that may benefit from additional salvage therapy. In this study, we aim to measure the inter-center variability of 90 Y PET measurements as measured on PET/MRI in preparation for a multi-institutional prospective phase I/II clinical trial. Eight institutions participated in this study and followed a standardized phantom filling and imaging protocol. The NEMA NU2-2012 body phantom was filled with 3 GBq of 90 Y chloride solution. The phantom was imaged for 30 min in listmode on a Siemens Biograph mMR non-TOF PET/MRI scanner at five time points across 10 days (0.3-3.0 GBq). Raw PET data were sent to a central site for image reconstruction and data analysis. Images were reconstructed with optimal parameters determined from a previous study. Volumes of interest (VOIs) matching the known sphere diameters were drawn on the vendor-provided attenuation map and propagated to the PET images. Recovery coefficients (RCs) and coefficient of variation of the RCs (COV) were calculated from these VOIs for each sphere size and activity level. Mean RCs ranged from 14.5 to 75.4%, with the lowest mean RC coming from the smallest sphere (10 mm) on the last day of imaging (0.16 MBq/ml) and the highest mean RC coming from the largest sphere (37 mm) on the first day of imaging (2.16 MBq/ml). The smaller spheres tended to exhibit higher COVs. In contrast, the larger spheres tended to exhibit lower COVs. COVs from the 37 mm sphere were  25%. Post-radioembolization dosimetry of lesions or other VOIs ≥ 22 mm in diameter can

  7. Targeting of liver tumour in rats by selective delivery of holmium-166 loaded microspheres: a biodistribution study

    Energy Technology Data Exchange (ETDEWEB)

    Nijsen, F.; Rook, D.; Zonnenberg, B.; Klerk, J. de; Rijk, P. van; Schip, F. van het [Dept. of Nuclear Medicine, University Medical Center, Utrecht (Netherlands); Brandt, C. [Animal Inst., Utrecht Univ. (Netherlands); Meijer, R. [Dept. of Radiology, Univ. Medical Center, Utrecht (Netherlands); Dullens, H. [Dept. of Pathology, Univ. Medical Center, Utrecht (Netherlands); Hennink, W. [Dept. of Pharmaceutics, Utrecht Univ. (Netherlands)

    2001-06-01

    Intra-arterial administration of beta-emitting particles that become trapped in the vascular bed of a tumour and remain there while delivering high doses, represents a unique approach in the treatment of both primary and metastatic liver tumours. Studies on selective internal radiation therapy of colorectal liver metastases using yttrium-90 glass microspheres have shown encouraging results. This study describes the biodistribution of 40-{mu}m poly lactic acid microspheres loaded with radioactive holmium-166, after intra-arterial administration into the hepatic artery of rats with implanted liver tumours. Radioactivity measurements showed >95% retention of injected activity in the liver and its resident tumour. The average activity detected in other tissues was {<=}0.1%ID/g, with incidental exceptions in the lungs and stomach. Very little {sup 166}Ho activity was detected in kidneys (<0.1%ID/g), thereby indicating the stability of the microspheres in vivo. Tumour targeting was very effective, with a mean tumour to liver ratio of 6.1{+-}2.9 for rats with tumour (n=15) versus 0.7{+-}0.5 for control rats (n=6; P<0.001). These ratios were not significantly affected by the use of adrenaline. Histological analysis showed that five times as many large (>10) and medium-sized (4-9) clusters of microspheres were present within tumour and peritumoural tissue, compared with normal liver. Single microspheres were equally dispersed throughout the tumour, as well as normal liver parenchyma. (orig.)

  8. Long-term conversion of 45S5 bioactive glass-ceramic microspheres in aqueous phosphate solution.

    Science.gov (United States)

    Fu, Hailuo; Rahaman, Mohamed N; Day, Delbert E; Huang, Wenhai

    2012-05-01

    The conversion of 45S5 glass and glass-ceramics to a hydroxyapatite (HA)-like material in vitro has been studied extensively, but only for short reaction times (typically glass-ceramic microspheres (designated 45S5c) in an aqueous phosphate solution. Microspheres of 45S5c (75-150 μm) were immersed for 10 years at room temperature (~25 °C) in K(2)HPO(4) solution with a concentration of 0.01 M or 1.0 M, and with a starting pH of 7.0 or 9.5. The reacted 45S5c microspheres and solutions were analyzed using structural and analytical techniques. Only 25-45 vol% of the 45S5c microspheres were converted to an HA-like material after the 10 year reaction. In solutions with a starting pH of 9.5, an increase in the K(2)HPO(4) concentration from 0.01 to 1.0 M resulted in a doubling of the volume of the microspheres converted to an HA-like material but had little effect on the composition of the HA-like product. In comparison, reaction of the 45S5c microspheres in the solution with a starting pH of 7.0 resulted in an HA-like product in the 0.01 M K(2)HPO(4) solution but a calcium pyrophosphate product, Ca(10)K(4)(P(2)O(7))(6).9H(2)O, in the 1.0 M solution. The consequences of these results for the long-term use of 45S5 glass-ceramics in biomedical applications are discussed.

  9. Tomographic bremsstrahlung imaging with yttrium-90 in the context of radioembolisation of liver tumors; Tomografische Bildgebung mit Yttrium-90-Bremsstrahlung im Rahmen der Radioembolisation von Lebertumoren

    Energy Technology Data Exchange (ETDEWEB)

    Grosser, Oliver Stephan

    2013-04-12

    Establish tomographic Bremsstrahlung SPECT imaging (BSPECT) for the clinical validation of Selective Internal Radiotherapy (SIRT) with Yttrium-90 ({sup 90}Y) labelled microspheres. Various energy ranges (75 ± 3.8 keV; 135 ± 6.8 keV; 167 ± 8.4 keV) and the summation window were studied to see if they were suitable for BSPECT. To this end, clinically available reconstruction techniques were analysed for their suitability for BSPECT. The tomographic examinations were performed on a cylindrical phantom filled with spheres of different diameters d = [28; 35; 40; 50; 60] mm in a non-active waterfilled background. The spheres were filled with identical {sup 90}Y activity concentration (AC). Measurements were conducted at AC = [14.58; 5.20; 1.98; 0.66] MBq/cm{sup 3}. The BSPECT were reconstructed with filtered back-projection (FBP), a 2D Ordered-Subset Expectation Maximisation Algorithm (2D-OSEM) and a 3D Geometric Mean Algorithm (3D-GMA). Evaluation was made visually and on the basis of objective performance parameters such as contrast, signal-to-noise ratio (SNR) and image noise. While the 75 keV ± 3.8 keV window was identified as suitable for the BSPECT, limitations were revealed as to use of different implementations of the Point Spread Function (PSF). It was found for all reconstruction techniques that, at a given sphere diameter, there existed a linear relationship between the AC in the spheres and the reconstructed pulse rate per volume element. The recovery effect was verified for small spheres. The iterative techniques were found to be suitable for the BSPECT at all AC. At low AC, the 3D-GMA exhibited the least noise and the highest SNR. The FBP turned out to be entirely inappropriate for the BSPECT. The narrow energy window in which the bremsstrahlung interferes with the characteristic X-radiation of lead can be used for BSPECT. In this approach, the tomographic data reconstructed with different algorithms exhibited a varying image quality, with the iterative

  10. Hanford isotope project strategic business analysis yttrium-90 (Y-90)

    International Nuclear Information System (INIS)

    1995-10-01

    The purpose of this analysis is to address the short-term direction for the Hanford yttrium-90 (Y-90) project. Hanford is the sole DOE producer of Y-90, and is the largest repository for its source in this country. The production of Y-90 is part of the DOE Isotope Production and Distribution (IP and D) mission. The Y-90 is ''milked'' from strontium-90 (Sr-90), a byproduct of the previous Hanford missions. The use of Sr-90 to produce Y-90 could help reduce the amount of waste material processed and the related costs incurred by the clean-up mission, while providing medical and economic benefits. The cost of producing Y-90 is being subsidized by DOE-IP and D due to its use for research, and resultant low production level. It is possible that the sales of Y-90 could produce full cost recovery within two to three years, at two curies per week. Preliminary projections place the demand at between 20,000 and 50,000 curies per year within the next ten years, assuming FDA approval of one or more of the current therapies now in clinical trials. This level of production would incentivize private firms to commercialize the operation, and allow the government to recover some of its sunk costs. There are a number of potential barriers to the success of the Y-90 project, outside the control of the Hanford Site. The key issues include: efficacy, Food and Drug Administration (FDA) approval and medical community acceptance. There are at least three other sources for Y-90 available to the US users, but they appear to have limited resources to produce the isotope. Several companies have communicated interest in entering into agreements with Hanford for the processing and distribution of Y-90, including some of the major pharmaceutical firms in this country

  11. Hanford isotope project strategic business analysis yttrium-90 (Y-90)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The purpose of this analysis is to address the short-term direction for the Hanford yttrium-90 (Y-90) project. Hanford is the sole DOE producer of Y-90, and is the largest repository for its source in this country. The production of Y-90 is part of the DOE Isotope Production and Distribution (IP and D) mission. The Y-90 is ``milked`` from strontium-90 (Sr-90), a byproduct of the previous Hanford missions. The use of Sr-90 to produce Y-90 could help reduce the amount of waste material processed and the related costs incurred by the clean-up mission, while providing medical and economic benefits. The cost of producing Y-90 is being subsidized by DOE-IP and D due to its use for research, and resultant low production level. It is possible that the sales of Y-90 could produce full cost recovery within two to three years, at two curies per week. Preliminary projections place the demand at between 20,000 and 50,000 curies per year within the next ten years, assuming FDA approval of one or more of the current therapies now in clinical trials. This level of production would incentivize private firms to commercialize the operation, and allow the government to recover some of its sunk costs. There are a number of potential barriers to the success of the Y-90 project, outside the control of the Hanford Site. The key issues include: efficacy, Food and Drug Administration (FDA) approval and medical community acceptance. There are at least three other sources for Y-90 available to the US users, but they appear to have limited resources to produce the isotope. Several companies have communicated interest in entering into agreements with Hanford for the processing and distribution of Y-90, including some of the major pharmaceutical firms in this country.

  12. Radiopharmaceuticals developed at the University of Missouri research reactor

    International Nuclear Information System (INIS)

    Ketring, A.R.; Ehrhardt, G.J.; Day, D.E.

    1997-01-01

    The University of Missouri Research Reactor (MURR) has put a great deal of effort in the last two decades into development of radiotherapeutic beta emitters as nuclear medicine radiotherapeutics for malignancies. This paper describes the development of two of these drugs, 153 Sm ethylenediaminetetra-methylene phosphonic acid (EDTMP) (Quadramet trademark) and 90 Y glass microspheres (TheraSphere trademark). Samarium-153 EDTMP is a palliative used to treat the pain of metastatic bone cancer without the side effects of narcotic pain killers. Yttrium-90 glass microspheres are delivered via hepatic artery catheter to embolize the capillaries of liver tumors and deliver a large radiation dose for symptom palliation and life prolonging purposes

  13. Optimized conditions for chelation of yttrium-90-DOTA immunoconjugates.

    Science.gov (United States)

    Kukis, D L; DeNardo, S J; DeNardo, G L; O'Donnell, R T; Meares, C F

    1998-12-01

    Radioimmunotherapy (RIT) with 90Y-labeled immunoconjugates has shown promise in clinical trials. The macrocyclic chelating agent 1,4,7,10-tetraazacyclododecane-N,N',N",N"'-tetraacetic acid (DOTA) binds 90Y with extraordinary stability, minimizing the toxicity of 90Y-DOTA immunoconjugates arising from loss of 90Y to bone. However, reported 90Y-DOTA immunoconjugate product yields have been typically only BAD) was conjugated to the monoclonal antibody Lym-1 via 2-iminothiolane (2IT). The immunoconjugate product, 2IT-BAD-Lym-1, was labeled in excess yttrium in various buffers over a range of concentrations and pH. Kinetic studies were performed in selected buffers to estimate radiolabeling reaction times under prospective radiopharmacy labeling conditions. The effect of temperature on reaction kinetics was examined. Optimal radiolabeling conditions were identified and used in eight radiolabeling experiments with 2IT-BAD-Lym-1 and a second immunoconjugate, DOTA-peptide-chimeric L6, with 248-492 MBq (6.7-13.3 mCi) of 90Y. Ammonium acetate buffer (0.5 M) was associated with the highest uptake of yttrium. On the basis of kinetic data, the time required to chelate 94% of 90Y (four half-times) under prospective radiopharmacy labeling conditions in 0.5 M ammonium acetate was 17-148 min at pH 6.5, but it was only 1-10 min at pH 7.5. Raising the reaction temperature from 25 degrees C to 37 degrees C markedly increased the chelation rate. Optimal radiolabeling conditions were identified as: 30-min reaction time, 0.5 M ammonium acetate buffer, pH 7-7.5 and 37 degrees C. In eight labeling experiments under optimal conditions, a mean product yield (+/- s.d.) of 91%+/-8% was achieved, comparable to iodination yields. The specific activity of final products was 74-130 MBq (2.0-3.5 mCi) of 90Y per mg of monoclonal antibody. The immunoreactivity of 90Y-labeled immunoconjugates was 100%+/-11%. The optimization of 90Y-DOTA chelation conditions represents an important advance in 90Y RIT

  14. Use of yttrium-90 microspheres (TheraSphere) in a patient with unresectable hepatocellular carcinoma leading to liver transplantation: a case report.

    Science.gov (United States)

    Kulik, Laura M; Mulcahy, Mary F; Hunter, Russell D; Nemcek, Albert A; Abecassis, Michael M; Salem, Riad

    2005-09-01

    Prior to therapy, model for end stage liver disease (MELD) scoring, diagnostic imaging and tumor staging were performed in a patient with T3 HCC. The patient received an orthotopic liver transplant (OLT) 42 days after treatment. The explant specimen showed complete necrosis of the target tumor. Follow-up of this patient has demonstrated no evidence of recurrence. There was no life threatening or fatal adverse experiences related to treatment. This case report documents the natural course, history and outcome of a patient treated with yttrium-90 for unresectable HCC. The patient was downstaged from T3 to T2 and was subsequently transplanted.

  15. A method for preparing a sintered glass powder for manufacturing microspheres

    International Nuclear Information System (INIS)

    Budrick, R.G.; King, F.T.; Nolen, R.L. Jr.; Solomon, D.E.

    1975-01-01

    The invention relates to the manufacture of sintered glass-powder. It relates to a method comprising the step of forming a vitreous gel so that it contains an occluded substance adapted to expand when heated, said gel being subsequently dried, then crushed and sorted prior to being washed and dried again. Application to the manufacture of sintered glass-powder for forming microspheres adapted to contain a thermonuclear fuel [fr

  16. Radioisotope generators for nuclear medicine based on Fajans adsorption on glass microspheres

    International Nuclear Information System (INIS)

    Ehrhardt, G.J.; Symes, S.; Guimon, R.K.; Zinn, K.R.

    1992-01-01

    Several radioisotope generator systems exist in which the carrier-free daughter product would precipitate if present in macro amounts at pH levels at which the parent is soluble. Included among these are the 68 Ge/ 68 Ga, 90 Sr/ 90 Y, and 47 Ca/ 47 Sc pairs. This paper reveals that in these systems, chemical separation can be achieved by Fajans adsorption of the radiocolloidal daughter products onto surfaces such as activated glass microspheres at an appropriate pH. This is followed by washing to remove the parent solution and desorption of the daughter crop by acid washes. Investigation of the Ge/Ga and Sr/Y systems demonstrated that this solid-phase extraction method is erratic, but can give daughter yields as high at 89% with separation factors up to ∼ 10,000 form parent isotope. This method has the potential for producing daughter isotopes with a minimum of metal and organic impurities for labeling cells, receptor binding ligands, and antibodies for diagnostic and radiotherapeutic purposes

  17. Radiopharmaceuticals developed at the University of Missouri research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ketring, A.R.; Ehrhardt, G.J. [Univ. of Missouri, Columbia, MO (United States); Day, D.E. [Univ. of Missouri, Rolla, MO (United States)

    1997-12-01

    The University of Missouri Research Reactor (MURR) has put a great deal of effort in the last two decades into development of radiotherapeutic beta emitters as nuclear medicine radiotherapeutics for malignancies. This paper describes the development of two of these drugs, {sup 153}Sm ethylenediaminetetra-methylene phosphonic acid (EDTMP) (Quadramet{trademark}) and {sup 90}Y glass microspheres (TheraSphere{trademark}). Samarium-153 EDTMP is a palliative used to treat the pain of metastatic bone cancer without the side effects of narcotic pain killers. Yttrium-90 glass microspheres are delivered via hepatic artery catheter to embolize the capillaries of liver tumors and deliver a large radiation dose for symptom palliation and life prolonging purposes.

  18. Treatment of persistent knee effusions with Yttrium 90

    International Nuclear Information System (INIS)

    Bouyoucef, S.E.; Drahmoune, R.; Mechken, F.; Amimour, A.; Hanni-Haddam, F.; Abtroun, F.; Sellah, M.; Mansouri, B.

    2002-01-01

    Yttrium 90 intra-articular injection is used in persisting active joint of the knee, where medication has failed to resolve chronic inflammation. The effective dose delivered to the synovia is linked to Y 90 activity and depends on the size of the joint space, the synovial structure and thickness and the inflammatory activity of the synovitis. The amount of the injected activity of Y90 was estimated according the volume effusion in 28 pathologic knee of 18 patients aged 18 years and more (mean age 46 years). All patients have persistent knee effusions and most of them have rheumatoid arthritis but others had ankylosing spondylitis, Behcet disease, psoriatic arthritis. According the radiological classification of Steinbrocker, 19 pathological knees were in stage 1, 5 in stage 2 and 4 in stage 3. The mean value of the monthly removed volume of the synovial liquid from the pathological knee was determined during the last month preceding the radiosynoviorthesis and four groups were identified: V0 no evidence of effusion liquid, 0 ml 100ml. The activity of Y 90 was estimated in order to obtain a total of 100 Gray in the envelope of 3 spherical phantoms with the same range of volume as defined above. The lowest activity of Y90, 111 MBq (3mCi) was determined for V0 according a mean value of standard sizes of knees. An activity of 18 MBq (0.5mCi) was added for each stage of 50 ml, so 129 MBq (3.5 mCi) for G1, 148 MBq (4 mCi) for G2 and 166 MBq (4.5 mCi) for G3. Efficacy of Y90 treatment was clinically assessed in all patients according to three parameters: pain, hydrarthrosis and range of joint movement at 1, 3, 6 and 12 months. The results were excellent in 13 knees and good in 9 and for most of them the efficacy of Y 90 was observed after 6 months. The results were less good in 3 knees but with an initial good evolution for all at 1 month. For 4 knees, the efficacy of Y 90 was bad. Although the small number of patients, these results show a high rate, 75%, of successful

  19. Comparative analysis of hepatopulmonary shunt obtained from pretherapy 99mTc MAA scintigraphy and post-therapy 90Y Bremsstrahlung imaging in 90Y microsphere therapy.

    Science.gov (United States)

    Jha, Ashish Kumar A; Zade, Anand A; Rangarajan, Venkatesh; Purandare, Nilendu; Shah, Sneha A; Agrawal, Archi; Kulkarni, Suyash S; Shetty, Nitin

    2012-05-01

    (99m)Tc macroaggregate albumin (MAA) scintigraphy is routinely used to estimate the hepatopulmonary shunt (HPS) of (90)Y microspheres because of their comparable average particle sizes (20-30 µm). However, the MAA particle size can vary from 10 to 90 µm. Therefore, HPS computed from (99m)Tc MAA scintigraphy may not accurately represent the HPS of (90)Y microspheres. In view of this, the present study was undertaken to investigate the accuracy of (99m)Tc MAA scintigraphy in estimating the HPS of (90)Y microspheres. Nineteen sessions of transarterial radioembolization using (90)Y therasphere were carried out in 17 patients for hepatic malignancies (both primary and secondary). For each session of therapy, a pretherapeutic (99m)Tc MAA scintigraphy and post-therapeutic (90)Y Bremsstrahlung scintigraphy were performed. The HPSs obtained from these images were compared. The mean HPS fractions calculated from the pretherapeutic (99m)Tc MAA study and the post-therapeutic (90)Y Bremsstrahlung images were 4.77 ± 2.81 and 4.52 ± 2.5%, respectively. The coefficient of correlation (r) was 0.96. (99m)Tc MAA scintigraphy accurately predicts the HPS of (90)Y microspheres.

  20. Successful treatment of Cushing's disease using yttrium-90 rods

    International Nuclear Information System (INIS)

    White, M.C.; Doyle, F.H.; Mashiter, K.; Joplin, G.F.

    1982-01-01

    Interstitial irradiation using yttrium-90 ( 90 Y) rods implanted by needle into the pituitary gland was used as primary treatment in 16 patients with pituitary dependent Cushing's disease. Clinical and biochemical remission was observed within three to six months in 13 and in the remaining three after a supplementary implant. There was no perioperative morbidity. Follow-up from the time of definitive operation ranged from six to 123 months (mean 39). No recurrence has been observed. The return of a normal diurnal cortisol rhythm has been observed in 10/12 patients studied after remission. Some form of long-term pituitary hormone replacement therapy was required in only the six patients who had received the largest irradiation dose. Implantation of 90 Y is safe and effective treatment for patients with Cushing's disease, comparing favourably with selective trans-sphenoidal pituitary surgery. (author)

  1. Yttrium-90 used to treat colon cancer: Awaiting investigational new drug approval

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    A new radiation treatment takes just 14 to 21 days to shrink colorectal tumors in laboratory mice, is under review for clinical trials with human cancer patients. The treatment has succeeded in reducing the size of tumors by up to 95%. Colon cancer, the second leading cause of cancer deaths in the US, is extremely difficult to treat unless it is detected early enough for surgical procedures. In laboratory tests over the last 5 years, a team of researchers has developed the treatment using yttrium-90. The yttrium-90 is transported to the tumors by attaching it to monoclonal antibodies that seek out the cancer cells. Once the radioisotope has been targeted to the tumor, the radiation destroys many of the cells, dramatically reducing the size of the tumor. Since this treatment usually does not completely eliminate all the cancer cells, it cannot be called a cure, but it does seem to be an effective method of shrinking colorectal tumors

  2. Process improvement for the safe delivery of multidisciplinary-executed treatments-A case in Y-90 microspheres therapy.

    Science.gov (United States)

    Cai, Bin; Altman, Michael B; Garcia-Ramirez, Jose; LaBrash, Jason; Goddu, S Murty; Mutic, Sasa; Parikh, Parag J; Olsen, Jeffrey R; Saad, Nael; Zoberi, Jacqueline E

    To develop a safe and robust workflow for yttrium-90 (Y-90) radioembolization procedures in a multidisciplinary team environment. A generalized Define-Measure-Analyze-Improve-Control (DMAIC)-based approach to process improvement was applied to a Y-90 radioembolization workflow. In the first DMAIC cycle, events with the Y-90 workflow were defined and analyzed. To improve the workflow, a web-based interactive electronic white board (EWB) system was adopted as the central communication platform and information processing hub. The EWB-based Y-90 workflow then underwent a second DMAIC cycle. Out of 245 treatments, three misses that went undetected until treatment initiation were recorded over a period of 21 months, and root-cause-analysis was performed to determine causes of each incident and opportunities for improvement. The EWB-based Y-90 process was further improved via new rules to define reliable sources of information as inputs into the planning process, as well as new check points to ensure this information was communicated correctly throughout the process flow. After implementation of the revised EWB-based Y-90 workflow, after two DMAIC-like cycles, there were zero misses out of 153 patient treatments in 1 year. The DMAIC-based approach adopted here allowed the iterative development of a robust workflow to achieve an adaptable, event-minimizing planning process despite a complex setting which requires the participation of multiple teams for Y-90 microspheres therapy. Implementation of such a workflow using the EWB or similar platform with a DMAIC-based process improvement approach could be expanded to other treatment procedures, especially those requiring multidisciplinary management. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  3. Acromegaly with sleep disturbances relieved by yttrium-90 pituitary implantation

    International Nuclear Information System (INIS)

    Rosenstock, J.; Doyle, F.H.; Joplin, G.F.; Jung, R.T.; Mashiter, K.

    1982-01-01

    A brief case history is presented of a patient, who, after yttrium-90 implantation, showed a complete clinical and hormonal remission of her acromegaly, maintaining normal pituitary function. The remarkable feature was the rapid disappearance of her attacks of somnolence within 96 hours of pituitary implantation, despite persistence of nocturnal snoring and well before any remodelling of soft tissues could have occurred. This response suggests that her daytime somnolence had a narcoleptic component. (author)

  4. Acromegaly with sleep disturbances relieved by yttrium-90 pituitary implantation

    Energy Technology Data Exchange (ETDEWEB)

    Rosenstock, J.; Doyle, F.H.; Joplin, G.F.; Jung, R.T.; Mashiter, K. (Hammersmith Hospital, London (UK). Postgraduate Medical School)

    1982-03-01

    A brief case history is presented of a patient, who, after yttrium-90 implantation, showed a complete clinical and hormonal remission of her acromegaly, maintaining normal pituitary function. The remarkable feature was the rapid disappearance of her attacks of somnolence within 96 hours of pituitary implantation, despite persistence of nocturnal snoring and well before any remodelling of soft tissues could have occurred. This response suggests that her daytime somnolence had a narcoleptic component.

  5. Spectrographic determination of strontium in yttrium-90 solutions

    International Nuclear Information System (INIS)

    Roca, M.; Capdevila, C.

    1970-01-01

    The copper spark method has been used for determining strontium in the concentration range 1-100 g/ml in yttrium-90 solutions containing 0,5 % or thereabouts of ammonium citrate. The influence of the citric acid as well as the ammonium citrate with regard to 2N HCL solutions has been studied: the citric acid enhances the line intensities of strontium. The employment of either barium or lanthanum as reference element compensates for this enhancement. Because of the increase in sensitivity mentioned above, the study of influence of the citric acid has been extended and several impurities usually determined in radioisotope solutions have been considered. (Author) 4 refs

  6. Optical bistability in Er-Yb codoped phosphate glass microspheres at room temperature

    NARCIS (Netherlands)

    Warda, Jonathan M.; O'Shea, Danny G.; Shortt, Brian J.; Chormaic, Sile Nic

    2007-01-01

    We experimentally demonstrate optical bistability in Er(3+)-Yb(3+) phosphate glass microspheres at 295 K. Bistability is associated with both Er(3+) fluorescence and lasing behavior, and chromatic switching. The chromatic switching results from an intrinsic mechanism exploiting the thermal coupling

  7. Comparison by quantitative scanning of the distribution in the body of yttrium-90 and gold-198 after intra-articular injection

    International Nuclear Information System (INIS)

    Williams, E.D.; Caughey, D.E.; John, M.B.; Hurley, P.J.

    1975-01-01

    A new radiopharmaceutical, yttrium-90 ferric hydroxide colloid, has been used to treat knee effusion in patients with rheumatoid arthritis. With a view to assessing absorbed radiation dose, a study was initiated to compare its body distribution with that of gold-198, which has also been used for this purpose. The treated knee was in each case scanned immediately after injection using a dual 5-inch detector scanner, and again two, four and seven days later, when the regional lymph nodes and liver were also scanned. Using calibration factors obtained by scanning water phantoms, data from the scans were used to calculate the percentage of the injected radioactivity in each site. Radioactivity in blood and urine was also measured. Ten knees have been treated, each with five mCi yttrium-90, and twelve with 10 mCi gold-198. The treated knee was immobilized, and the patient rested in bed for four days, to minimize loss of radioactivity from the knee. With this procedure, both radionuclides were found to be equally well retained in the knee. However, the lymph node uptake of yttrium was lower than for gold. Yttrium-90 emits only beta radiation, so the gonadal radiation done in patients treated with yttrium-90 is estimated to be much less than in those treated with gold-198. (author)

  8. Study of the focusing effect of silica microspheres on the upconversion of Er3+–Yb3+ codoped glass ceramics

    International Nuclear Information System (INIS)

    Pérez-Rodríguez, C.; Imanieh, M.H.; Martín, L.L; Ríos, S.; Martín, I.R.; Yekta, Bijan Eftekhari

    2013-01-01

    Highlights: •Silica microspheres have been located on the surface of glass and glass ceramics samples codoped with Er and Yb. •Microspheres act as microlens of the 950 nm excitation light resulting in focalized excited regions in the samples with sizes under the micron. •Intense red upconversion is achieved in the focalized areas. •Microspheres collect the upconversion emission light, scoping with the together microlensing properties an enhancement of the detected signal in a 3x factor. •Performed Finite-Difference Time-Domain simulations predict the size of the focalized regions in good agreement with the experimental measurements. -- Abstract: The upconversion emission properties of Er 3+ –Yb 3+ codoped glass and glass ceramic samples with different Si/Al ratios and thermal treatments were analyzed by covering their surfaces with silica microspheres (3.8 μm diameter). A 950 nm laser beam is focused by the microspheres producing a set of photonic nanojets near the surface of the samples. After the upconversion processes of the Er 3+ ions located in each microsphere focus area, these ions emit light in the green and red regions. The red emission from each sample was measured, yielding an upconversion intensity in the focal areas three times higher than the emission from the bare substrate. To estimate the real size of the red emission area under a single microsphere, a deconvolution of the measured focal spots with the Point Spread Function of the experimental setup was performed, resulting in a Full Width at Half Maximum of 330 nm. The results obtained by Finite-Difference Time-Domain simulations are in good agreement with the experimental values

  9. Clinical impact of 99mTc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with 90Y-loaded microspheres

    International Nuclear Information System (INIS)

    Garin, Etienne; Rolland, Yan; Laffont, Sophie; Edeline, Julien

    2016-01-01

    Radioembolization with 90 Y-loaded microspheres is increasingly used in the treatment of primary and secondary liver cancer. Technetium-99 m macroaggregated albumin (MAA) scintigraphy is used as a surrogate of microsphere distribution to assess lung or digestive shunting prior to therapy, based on tumoral targeting and dosimetry. To date, this has been the sole pre-therapeutic tool available for such evaluation. Several dosimetric approaches have been described using both glass and resin microspheres in hepatocellular carcinoma (HCC) and liver metastasis. Given that each product offers different specific activities and numbers of spheres injected, their radiobiological properties are believed to lightly differ. This paper summarizes and discusses the available studies focused on MAA-based dosimetry, particularly concentrating on potential confounding factors like clinical context, tumor size, cirrhosis, previous or concomitant therapy, and product used. In terms of the impact of tumoral dose in HCC, the results were concordant and a response relationship and tumoral threshold dose was clearly identified, especially in studies using glass microspheres. Tumoral dose has also been found to influence survival. The concept of treatment intensification has recently been introduced, yet despite several studies publishing interesting findings on the tumor dose-metastasis relationship, no consensus has been reached, and further clarification is thus required. Nor has the maximal tolerated dose to the liver been well documented, requiring more accurate evaluation. Lung dose was well described, despite recently identified factors influencing its evaluation, requiring further assessment. MAA SPECT/CT dosimetry is accurate in HCC and can now be used in order to achieve a fully customized approach, including treatment intensification. Yet further studies are warranted for the metastasis setting and evaluating the maximal tolerated liver dose. (orig.)

  10. Fabry-Perot interferometer fiber tip sensor based on a glass microsphere glued at the etched end of multimode fiber

    Science.gov (United States)

    Chen, Weiping P.; Wang, Dongning N.; Xu, Ben; Wang, Zhaokun K.; Zhao, Chun-Liu

    2017-05-01

    We demonstrate an optical Fabry-Perot interferometer fiber tip sensor based on a glass microsphere glued at the etched end of a multimode fiber. The fiber device is miniature and robust, with a convenient reflection mode of operation, a high temperature sensitivity of 202.6 pm/°C within the range from 5°C to 90°C, a good refractive index sensitivity of ˜119 nm/RIU within the range from 1.331 to 1.38, and a gas pressure sensitivity of 0.19 dB/MPa.

  11. An investigation into the effects of residual water on the glass transition temperature of polylactide microspheres using modulated temperature DSC.

    Science.gov (United States)

    Passerini, N; Craig, D Q

    2001-05-18

    The objective of the study was to ascertain residual water levels in polylactide and polylactide-co-glycolide microspheres prepared using the solvent evaporation technique and to investigate the effects of that water on the glass transitional behaviour of the microspheres. Microspheres were prepared from polylactic acid (PLA) and polylactide-co-glycolide (PLGA) 50:50 and 75:25 using a standard solvent evaporation technique. The glass transition was measured as a function of drying conditions using modulated temperature DSC. The microspheres were found to contain very low levels of dichloromethane, while residual water levels of up to circa 3% w/w were noted after freeze or oven drying, these levels being higher for microspheres containing higher glycolic acid levels. The residual water was found to lower the T(g) following the Gordon-Taylor relationship. The data indicate that the microparticles may retain significant water levels following standard preparation and drying protocols and that this drying may markedly lower the T(g) of the spheres.

  12. Childhood acromegaly successfully treated with interstitial irradiation using Yttrium-90

    International Nuclear Information System (INIS)

    Rosenstock, J.; Doyle, F.H.; Mashiter, K.; Joplin, G.F.

    1982-01-01

    A child with a growth hormone producing tumour presented at the age of 4 1/2 years. The onset of the disease was at 18 months of age. Treatment was given with three doses of interstitial irradiation using yttrium-90 implants. There were no local complications from the procedures. Now, 11 years after diagnosis, she is asymptomatic, of normal appearance, and her height and the size of the pituitary fossa are normal. Growth hormone levels are almost normal, thyroid function is intact, and she is maintained on prednisone and sex hormones. (Authors)

  13. Childhood acromegaly successfully treated with interstitial irradiation using Yttrium-90

    Energy Technology Data Exchange (ETDEWEB)

    Rosenstock, J.; Doyle, F.H.; Mashiter, K.; Joplin, G.F. (Royal Postgraduate Medical School, Hammersmith Hospital, London (UK). Dept. of Medicine and Radiology); Hall, R. (Royal Victoria Infirmary, Newcastle upon Tyne (UK))

    1982-01-01

    A child with a growth hormone producing tumour presented at the age of 4 1/2 years. The onset of the disease was at 18 months of age. Treatment was given with three doses of interstitial irradiation using Yttrium-90 implants. There were no local complications from the procedures. Now, 11 years after diagnosis, she is asymptomatic, of normal appearance, and her height and the size of the pituitary fossa are normal. Growth hormone levels are almost normal, thyroid function is intact, and she is maintained on prednisone and sex hormones.

  14. Study of the focusing effect of silica microspheres on the upconversion of Er{sup 3+}–Yb{sup 3+} codoped glass ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Pérez-Rodríguez, C., E-mail: cjperez@ull.edu.es [Dpto. Física Fundamental y Experimental, Electrónica y Sistemas, Universidad de La Laguna, Av. Astrofísico Francisco Sánchez, s/n E-38206 La Laguna, Tenerife (Spain); Imanieh, M.H. [Department of Chemical and Environmental Engineering, University of Toledo, Toledo, OH (United States); Department of Materials, Ceramic Division, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of); Martín, L.L [Dpto. Física Fundamental y Experimental, Electrónica y Sistemas, Universidad de La Laguna, Av. Astrofísico Francisco Sánchez, s/n E-38206 La Laguna, Tenerife (Spain); Ríos, S. [Dpto. de Física Básica, Universidad de La Laguna, Av. Astrofísico Francisco Sánchez, s/n E-38206 La Laguna, Tenerife (Spain); Martín, I.R. [Dpto. Física Fundamental y Experimental, Electrónica y Sistemas, Universidad de La Laguna, Av. Astrofísico Francisco Sánchez, s/n E-38206 La Laguna, Tenerife (Spain); MALTA Consolider Team, Av. Astrofísico Francisco Sánchez, s/n E-38206 La Laguna, Tenerife (Spain); Yekta, Bijan Eftekhari [Department of Materials, Ceramic Division, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of)

    2013-11-05

    Highlights: •Silica microspheres have been located on the surface of glass and glass ceramics samples codoped with Er and Yb. •Microspheres act as microlens of the 950 nm excitation light resulting in focalized excited regions in the samples with sizes under the micron. •Intense red upconversion is achieved in the focalized areas. •Microspheres collect the upconversion emission light, scoping with the together microlensing properties an enhancement of the detected signal in a 3x factor. •Performed Finite-Difference Time-Domain simulations predict the size of the focalized regions in good agreement with the experimental measurements. -- Abstract: The upconversion emission properties of Er{sup 3+}–Yb{sup 3+} codoped glass and glass ceramic samples with different Si/Al ratios and thermal treatments were analyzed by covering their surfaces with silica microspheres (3.8 μm diameter). A 950 nm laser beam is focused by the microspheres producing a set of photonic nanojets near the surface of the samples. After the upconversion processes of the Er{sup 3+} ions located in each microsphere focus area, these ions emit light in the green and red regions. The red emission from each sample was measured, yielding an upconversion intensity in the focal areas three times higher than the emission from the bare substrate. To estimate the real size of the red emission area under a single microsphere, a deconvolution of the measured focal spots with the Point Spread Function of the experimental setup was performed, resulting in a Full Width at Half Maximum of 330 nm. The results obtained by Finite-Difference Time-Domain simulations are in good agreement with the experimental values.

  15. The sequential separation of strontium-90, yttrium-90, promethium-147, and cerium-144 from urine and their subsequent estimation

    International Nuclear Information System (INIS)

    Kramer, G.H.; Davies, J.M.

    1981-04-01

    A method has been developed for separating low-level activities of the beta-emitting isotopes strontium-90, yttrium-90, promethium-147 and cerium-144 from urine and aqueous solutions. They are subsequently estimated by planchet or liquid scintillation counting. The radionuclides are separated from each other and from interfering elements by solvent extraction with HDEHP (di-2-ethylhexyl phosphoric acid) in n-heptane. It is possible to separate the elements with a minimum of cross-contamination by selecting appropriate pH's and solvent concentrations. Percentage recoveries for the radionuclides are: 90 Sr, 100 +- 12; 90 Y, 65 +- 4; 147 Pm, 90 +- 8; 144 Ce, 87 +- 11. The limits of detection are: 90 Sr, 0.6 pCi; 90 Y, 0.7 pCi; 147 Pm, 1.0 pCi; 144 Ce, 0.8 pCi. (author)

  16. Optimization of the personnel radiation protection during the treatment by antibodies labelled by yttrium 90

    International Nuclear Information System (INIS)

    Legrand, J.; Prangere, T.; Cougnenc, O.; Leleu, C.; Huglo, D.; Morschhauser, F.

    2007-01-01

    Beyond the acquired experience limiting the exposure time, measures of adequate radiation protection allow to reduce the doses of surface received to extremities by the personnel participating to the preparation of treatments by antibodies labelled by yttrium 90. (N.C.)

  17. Treatment of exhaust fluorescent lamps to recover yttrium: Experimental and process analyses

    International Nuclear Information System (INIS)

    De Michelis, Ida; Ferella, Francesco; Varelli, Ennio Fioravante; Veglio, Francesco

    2011-01-01

    Highlights: → Recovery of yttrium from spent fluorescent lamps by sulphuric acid leaching. → The use of sulphuric acid allows to reduce calcium dissolutions. → Main contaminant of fluorescent powder are Si, Pb, Ca and Ba. → Hydrated yttrium oxalate, recovered by selective precipitation, is quite pure (>90%). → We have studied the whole process for the treatment of dangerous waste (plant capability). - Abstract: The paper deals with recovery of yttrium from fluorescent powder coming from dismantling of spent fluorescent tubes. Metals are leached by using different acids (nitric, hydrochloric and sulphuric) and ammonia in different leaching tests. These tests show that ammonia is not suitable to recover yttrium, whereas HNO 3 produces toxic vapours. A full factorial design is carried out with HCl and H 2 SO 4 to evaluate the influence of operating factors. HCl and H 2 SO 4 leaching systems give similar results in terms of yttrium extraction yield, but the last one allows to reduce calcium extraction with subsequent advantage during recovery of yttrium compounds in the downstream. The greatest extraction of yttrium is obtained by 20% w/v S/L ratio, 4 N H 2 SO 4 concentration and 90 deg. C. Yttrium and calcium yields are nearly 85% and 5%, respectively. The analysis of variance shows that acid concentration alone and interaction between acid and pulp density have a significant positive effect on yttrium solubilization for both HCl and H 2 SO 4 medium. Two models are empirically developed to estimate yttrium and calcium concentration during leaching. Precipitation tests demonstrate that at least the stoichiometric amount of oxalic acid is necessary to recover yttrium efficiently and a pure yttrium oxalate n-hydrate can be produced (99% grade). The process is economically feasible if other components of the fluorescent lamps (glass, ferrous and non-ferrous scraps) are recovered after the equipment dismantling and valorized, besides the cost that is usually paid

  18. Improvements in processing characteristics and engineering properties of wood flour-filled high density polyethylene composite sheeting in the presence of hollow glass microspheres

    Science.gov (United States)

    Baris Yalcin; Steve E Amos; Andrew S D Souza; Craig M Clemons; I Sedat Gunes; Troy K Ista

    2012-01-01

    Hollow glass microspheres were introduced into wood flour/high density polyethylene composites by melt compounding in a twin-screw extruder. The prepared composites were subsequently converted to extruded profiles in order to obtain composite sheeting. The presence of hollow glass microspheres highly reduced the density of the extruded sheets down to 0.9 g/cc, while...

  19. Low pressure gas filling of laser fusion microspheres

    International Nuclear Information System (INIS)

    Koo, J.C.; Dressler, J.L.; Hendricks, C.D.

    1979-01-01

    In our laser fusion microsphere production, large, thin gel-microspheres are formed before the chemicals are fused into glass. In this transient stage,, the gel-microspheres are found to be highly permeable to argon and many other inert gases. When the gel transforms to glass, the argon gas, for example, is trapped within to form argon filled, fusion target quality, glass microspheres. On the average, the partial pressure of the argon fills attained in this process is around 2 x 10 4 Pa at room temperature

  20. Factors influencing the deposition of hydroxyapatite coating onto hollow glass microspheres

    International Nuclear Information System (INIS)

    Jiao, Yan; Xiao, Gui-Yong; Xu, Wen-Hua; Zhu, Rui-Fu; Lu, Yu-Peng

    2013-01-01

    Hydroxyapatite (HA) and HA coated microcarriers for cell culture and delivery have attracted more attention recently, owing to the rapid progress in the field of tissue engineering. In this research, a dense and uniform HA coating with the thickness of about 2 μm was successfully deposited on hollow glass microspheres (HGM) by biomimetic process. The influences of SBF concentration, immersion time, solid/liquid ratio and activation of HGM on the deposition rate and coating characteristics were discussed. X-ray diffraction (XRD) and Fourier transform infrared spectrum (FTIR) analyses revealed that the deposited HA is poorly crystalline. The thickness of HA coating showed almost no increase after immersion in 1.5SBF for more than 15 days with the solid/liquid ratio of 1:150. At the same time, SBF concentration, solid/liquid ratio and activation treatment played vital roles in the formation of HA coating on HGM. This poorly crystallized HA coated HGM could have potential use as microcarrier for cell culture. Highlights: • HA coatings were deposited on hollow glass microspheres by biomimetic process. • The obtained HA coating was poorly crystalline and carbonated. • The influencing factors of deposition rate and coating characteristics were studied. • The thickness of HA coating showed almost no increase after immersion for 15 days

  1. Investigating the effect of silver coating on the solubility, antibacterial properties, and cytocompatibility of glass microspheres.

    Science.gov (United States)

    Haas, L M; Smith, C M; Placek, L M; Hall, M M; Gong, Y; Mellott, N P; Wren, Anthony W

    2015-10-01

    Silver (Ag) coatings have been incorporated into many medical materials due to its ability to eradicate harmful microbes. In this study, glass microspheres (SiO2-Na2O-CaO-Al2O3) were synthesized and employed as substrates to investigate the effect Ag coating has on glass solubility and the subsequent biological effects. Initially, glasses were amorphous with a glass transition point (T(g)) of 605℃ and microspheres were spherical with a mean particle diameter of 120 µm (±27). The Ag coating was determined to be crystalline in nature and its presence was confirmed using scanning electron microscopy and X-ray photoelectron spectroscopy. Ion release determined that Ag-coated (Ag-S) microspheres increased the Na(+) release rate but slightly reduced the Ca(2+) and Si(4+) release compared to an uncoated control (UC-S). Additionally, the Ag-S reduced the pH to just above neutral (7.3-8.5) compared to the UC-S (7.7-9.1). Antibacterial testing determined significant reductions in planktonic Escherichia coli (p = 0.000), Staphylococcus epidermidis (p = 0.000) and Staphylococcus aureus (p = 0.000) growth as a function of the presence of Ag and with respect to maturation (1, 7, and 30 days). Testing for toxicity levels using L929 Fibroblasts determined higher cell viability for the Ag-S at lower concentrations (5 µg/ml); in addition, no significant reduction in cell viability was observed with higher concentrations (15, 30 µg/ml). © The Author(s) 2015.

  2. Long-Term Palliative Effect of Stenting in Gastric Outlet Obstruction Due to Transarterial Chemoembolization with Yttrium-90 in a Patient with Metastatic Neuroendocrine Tumor

    Directory of Open Access Journals (Sweden)

    Erkan Caglar

    2016-09-01

    Full Text Available Internal radioembolization with yttrium-90 is a promising treatment method, predominantly for liver tumors. However, the shifting of yttrium-90-loaded spherules into the arteries and veins that supply the duodenum and stomach, leading to ulceration, hemorrhage, perforation, and outlet obstruction of these organs, is one of the major undesirable consequences of this technique. We report a case of gastric outlet obstruction (GOO due to antropyloric stenosis with ulceration, edema, and inflammation following transarterial yttrium-90 treatment for a metastatic neuroendocrine tumor in a 58-year-old man. Stenting was used for palliation in this case. GOO improved after stenting and recovery of oral intake was permanent after stent removal.

  3. A revised method of labeling mouse IgG with yttrium-90

    International Nuclear Information System (INIS)

    Arbab, A.S.; Koizumi, Kiyoshi; Araki, Tsutomu

    1996-01-01

    We report the successful labeling of mouse IgG with yttrium-90 (Y-90) using isothiocyanatobenzyl-ethylenediaminetetraacetic acid (SCN-Bz-EDTA) as a chelating agent and compared the result with labeling by indium-111 (In-111). After conjugating IgG with SCN-Bz-EDTA, a predetermined volume of conjugated IgG was mixed with different volumes of either Y-90 or In-111 acetate and incubated at 37degC. Labeling efficiency was assessed at specific intervals upto 3 hr. After 3 hr, the mixtures were challenged with Na 2 EDTA to evaluate the transchelation of labeled Y-90 or In-111. All mixtures showed labeling efficiency of around 50% with Y-90 and the leveling was fairly preserved even after Na 2 EDTA challenge. However, labeling with In-111 was unsuccessful when conjugated IgG was not separated from the unconjugated form. When separated, however, In-111 showed more than 80% labeling efficiency though labeling with In-111 could not tolerate Na 2 EDTA challenge. In conclusion IgG was efficiently labeled by Y-90 using SCN-Bz-EDTA though labeling with In-111 showed some problems associated with this method. (author)

  4. Determination of Radiation Absorbed Dose to Primary Liver Tumors and Normal Liver Tissue Using Post Radioembolization 90Y PET

    Directory of Open Access Journals (Sweden)

    Shyam Mohan Srinivas

    2014-10-01

    Full Text Available Background: Radioembolization with Yttrium-90 (90Y microspheres is becoming a more widely used transcatheter treatment for unresectable hepatocellular carcinoma (HCC. Using post-treatment 90Y PET/CT scans,the distribution of microspheres within the liver can be determined and quantitatively assessesed . We studied the radiation dose of 90Y delivered to liver and treated tumors.Methods: This retrospective study of 56 patients with HCC, including analysis of 98 liver tumors, measured and correlated the dose of radiation delivered to liver tumors and normal liver tissue using glass microspheres (TheraSpheres® to the frequency of complications with mRECIST. 90Y PET/CT and triphasic liver CT scans were used to contour treated tumor and normal liver regions and determine their respective activity concentrations. An absorbed dose factor was used to convert the measured activity concentration (Bq/mL to an absorbed dose (Gy.Results: The 98 studied tumors received a mean dose of 169 Gy (mode 90-120 Gy;range 0-570 Gy. Tumor response by mRECIST criteria was performed for 48 tumors that had follow up scans. There were 21 responders (mean dose 215 Gy and 27 nonresponders (mean dose 167 Gy. The association between mean tumor absorbed dose and response suggests a trend but did not reach statistical significance (p=0.099. Normal liver tissue received a mean dose of 67 Gy (mode 60-70 Gy; range 10-120 Gy. There was a statistically significant association between absorbed dose to normal liver and the presence of two or more severe complications (p=0.036.Conclusion: Our cohort of patients showed a possible dose response trend for the tumors. Collateral dose to normal liver is nontrivial and can have clinical implications. These methods help us understand whether patient adverse events, treatment success, or treatment failure can be attributed to the dose which the tumor or normal liver received.

  5. Positron-emitting resin microspheres as surrogates of 90Y SIR-Spheres: a radiolabeling and stability study

    International Nuclear Information System (INIS)

    Avila-Rodriguez, Miguel A.; Selwyn, Reed G.; Hampel, Joseph A.; Thomadsen, Bruce R.; DeJesus, Onofre T.; Converse, Alexander K.; Nickles, Robert J.

    2007-01-01

    Commercially available resin microspheres and SIR-Spheres were labeled with metallic positron emitters and evaluated as positron emission tomography (PET) imaging surrogates of 90 Y SIR-Spheres. Radiolabeling was performed using a batch method, and in vitro stability over 24 h was evaluated in saline at physiological pH at 37 o C. The activity per microsphere distribution, as evaluated by autoradiography, showed the activity per microsphere to be proportional to the square radius of the spheres, suggesting surface binding. The in vivo stability of radiolabeling was evaluated in rats by micro-PET imaging after the intravenous injection of labeled microspheres. The different resin microspheres and radionuclides evaluated in this study all showed good radiolabeling efficiency and in vitro stability. However, only resins labeled with 86 Y and 89 Zr proved to have the in vivo stability required for clinical applications

  6. Clinical impact of {sup 99m}Tc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with {sup 90}Y-loaded microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Garin, Etienne [Cancer Institute Eugene Marquis, Department of Nuclear Medicine, Rennes (France); University of Rennes 1, Rennes (France); INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Rolland, Yan [Cancer Institute Eugene Marquis, Department of Medical Imaging, Rennes (France); Laffont, Sophie [University of Rennes 1, Rennes (France); Edeline, Julien [University of Rennes 1, Rennes (France); INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Cancer Institute Eugene Marquis, Department of Medical Oncology, Rennes (France)

    2016-03-15

    Radioembolization with {sup 90}Y-loaded microspheres is increasingly used in the treatment of primary and secondary liver cancer. Technetium-99 m macroaggregated albumin (MAA) scintigraphy is used as a surrogate of microsphere distribution to assess lung or digestive shunting prior to therapy, based on tumoral targeting and dosimetry. To date, this has been the sole pre-therapeutic tool available for such evaluation. Several dosimetric approaches have been described using both glass and resin microspheres in hepatocellular carcinoma (HCC) and liver metastasis. Given that each product offers different specific activities and numbers of spheres injected, their radiobiological properties are believed to lightly differ. This paper summarizes and discusses the available studies focused on MAA-based dosimetry, particularly concentrating on potential confounding factors like clinical context, tumor size, cirrhosis, previous or concomitant therapy, and product used. In terms of the impact of tumoral dose in HCC, the results were concordant and a response relationship and tumoral threshold dose was clearly identified, especially in studies using glass microspheres. Tumoral dose has also been found to influence survival. The concept of treatment intensification has recently been introduced, yet despite several studies publishing interesting findings on the tumor dose-metastasis relationship, no consensus has been reached, and further clarification is thus required. Nor has the maximal tolerated dose to the liver been well documented, requiring more accurate evaluation. Lung dose was well described, despite recently identified factors influencing its evaluation, requiring further assessment. MAA SPECT/CT dosimetry is accurate in HCC and can now be used in order to achieve a fully customized approach, including treatment intensification. Yet further studies are warranted for the metastasis setting and evaluating the maximal tolerated liver dose. (orig.)

  7. Evaluation of factors affecting tumor response and survival in patients with primary and metastatic liver cancer treated with microspheres.

    Science.gov (United States)

    Demirelli, Serkan; Erkilic, Metin; Oner, Ali Ozan; Budak, Evrim Surer; Gunduz, Seyda; Ozgur, Ozhan; Bozcuk, Hakan; Sindel, Hakki Timur; Boz, Adil

    2015-04-01

    Radioembolization with the yttrium-90 (Y-90) microspheres is being used increasingly more often in the treatment of patients with primary or metastatic liver cancer. Although technetium-99m macroaggregated albumin (Tc-99m MAA) scintigraphy performed following diagnostic angiography has an important role in predicting the effectiveness of treatment and in dose estimation, the number of studies using quantitative assessment of Tc-99m MAA scintigraphy is limited in this field. In the present study, the aim was to assess whether a tumor dose is required to obtain objective tumor response and to check whether this threshold value is predictive in terms of tumor response, survival, and liver toxicity by using Tc-99m MAA single-photon emission computed tomography (SPECT) images. Overall, 54 patients (20 women and 34 men; median age: 60 years) who underwent Y-90 Resin (SIR-Spheres) and Glass (TheraSphere) microsphere treatment with a diagnosis of unresectable liver cancer between August 2010 and April 2013 were included in the study. The mean doses to normal liver and tumor were estimated for each patient using Tc-99m MAA SPECT images and the medical internal radiation dosimetry method. The responses were assessed according to Response Evaluation Criteria In Solid Tumors (RECIST) and European Organisation for Research and Treatment of Cancer (EORTC) criteria. Kaplan-Meier survival curves and univariate Cox regression analysis were used in survival analysis. The relationship between treatment response and other parameters included was assessed using logistic regression analysis. The variables with a P value less than 0.01 in univariate analysis were assessed with multivariate analysis. Fifty-four Y-90 microsphere treatments (eight by using a Y-90 glass microsphere and 46 by using a Y-90 resin microsphere) were performed. In the multivariate analysis, the only parameter related to response was tumor dose (P<0.01). With a tumor dose of 280 Gy or higher, objective tumor

  8. Use of Yttrium-90 TheraSphere for the treatment of unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Liu, Michael D; Uaje, Michelle B; Al-Ghazi, Muthana S; Fields, Denise; Herman, June; Kuo, Jeffrey V; Milne, Norah; Nguyen, Thong H; Ramsinghani, Nilam S; Tokita, Kenneth M; Tsai, Fong Y; Vajgrt, Duane J; Imagawa, David K

    2004-11-01

    This is a retrospective analysis of a new treatment modality, intra-arterial administration of Yttrium-90 TheraSphere, for unresectable hepatocellular carcinoma (HCC). Patients with HCC not amenable to surgical treatment who had satisfactory physiological function without comorbid disease or significant pulmonary shunting were eligible for treatment. Patients were categorized into complete, partial, or no response based on serum alpha-fetoprotein (AFP) levels and CT or MRI imaging. Fourteen patients were considered candidates for treatment. Three patients were excluded due to significant hepatopulmonary shunting. Eleven patients were treated with TheraSphere. One patient (9%) had a complete response, eight patients (78%) had a partial response, and two patients (18%) showed no response. Partial and complete responders with AFP-associated HCC demonstrated a median decrease in AFP levels of 79 per cent at 73 days. No patients developed liver toxicity nor died due to treatment. Five patients (45%) died of progressive disease at a median of 7 months post-treatment. Six patients (54%) were alive at a median of 11 months (range, 9 to 20 months). Okuda stage 2 and 3 patients showed a median survival of 11 months and 7 months, respectively. Yttrium-90 TheraSphere treatment for unresectable hepatocellular carcinoma is well tolerated and appears to extend survival.

  9. Effect of intra-articular yttrium-90 on chronic pyrophosphate arthropathy of the knee

    International Nuclear Information System (INIS)

    Doherty, M.; Dieppe, P.A.

    1981-01-01

    Fifteen patients with bilateral, symmetrical chronic pyrophosphate arthropathy of the knee were given intra-articular injections of yttrium-90 (5 mCi) plus steroid (triamcinolone hexacetonide, 20 mg) into one knee, and saline plus steroid into the other (control) knee. Allocation of the 90 Y injection was random and double blind. After 6 months there was significantly less pain, inactivity stiffness, joint-line tenderness, and effusion in the 90 Y-injected knees than in the controls (p 90 Y-injected and control knees in the changes in range of movement (p 90 Y may be of benefit in chronic pyrophosphate arthropathy, a disease for which there is no treatment. The predilection of this condition to affect the knees of the elderly makes such treatment highly suitable because the joint lends itself readily to injection and the procedure carries very few actual or potential risks in this age group. (author)

  10. Treatment of persistent knee synovitis with Yttrium 90

    International Nuclear Information System (INIS)

    Bouyoucef, S.E.

    2007-01-01

    Full text: Management of persistent knee synovitis includes both systemic and local articular treatment relevant to specific etiology. Local treatment may involve attempts to control inflammation and pain in knee joints by intra articular application of analgesics or glucocorticoids. However, in many patients these fail to reduce significantly the synovitis phenomenon and moreover they may lead to severe side effects. Radiosynoviorthesis with Y90 has been in use for many years in several joint pathologies. Indications of Radiosynoviorthesis include various inflammatory and degenerative diseases and its use should be envisaged when other conservative methods have failed like intra articular injections of long acting corticosteroids. Persistent knee synovitis is defined by the presence of hydrops in the joint or functional impairment with warmth, pain and local signs and symptoms requiring intra articular injection of glucocorticoids. In this study, 151 knees with persistent knee synovitis have been treated with Y 90 and have had all a minimum of one year follow up. Many parameters have been identified to measure efficiency of the RSO including pain, hydarthrosis, mobility, as well as global perception of the patients. Excellent and good responses have been appreciated through pain at rest, pain at stress, volume of effusion, and articular mobility. Results showed that percentage of excellent and good response is superior to 80% at three and six months. Success of Y 90 appears to be higher for rheumatoid arthritis as well as for oligoarthritis. Whatever the etiology, intensity of the inflammatory process appears one the major parameters which could better predict the outcomes of yttrium 90 in persistent knee synovitis. (author)

  11. Analysis of Prognostic Factors After Yttrium-90 Radioembolization of Advanced Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Inarrairaegui, Mercedes; Martinez-Cuesta, Antonio; Rodriguez, Macarena; Bilbao, J. Ignacio

    2010-01-01

    Purpose: To analyze which patient-, tumor-, and treatment-related factors may influence outcome after 90 Y radioembolization ( 90 Y-RE) for hepatocellular carcinoma (HCC). Patients and Methods: Seventy-two consecutive patients with advanced HCC treated with 90 Y-RE were studied to detect which factors may have influenced response to treatment and survival. Results: Median overall survival was 13 months (95% confidence interval, 9.6-16.3 months). In univariate analysis, survival was significantly better in patients with one to five lesions (19 vs. 8 months, p = 0.001) and in patients with alpha-fetoprotein 52 UI/mL, and their survival in the multivariate analysis was significantly worse (hazard ratio, 4.7; 95% confidence interval, 13-1.73) (p = 0.002). Conclusions: Yttrium-90 radioembolization results in control of target lesions in the majority of patients with HCC but does not prevent the development of new lesions. Survival of patients treated with 90 Y-RE seems to depend largely on factors related to the aggressiveness of the disease (number of nodules, levels of alpha-fetoprotein, and presence of microscopic disease).

  12. PET optimization for improved assessment and accurate quantification of {sup 90}Y-microsphere biodistribution after radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Martí-Climent, Josep M., E-mail: jmmartic@unav.es; Prieto, Elena; Elosúa, César; Rodríguez-Fraile, Macarena; Domínguez-Prado, Inés; Vigil, Carmen; García-Velloso, María J.; Arbizu, Javier; Peñuelas, Iván; Richter, José A. [Nuclear Medicine Department, Clínica Universidad de Navarra, 36, Pío XII Avenue, 31008 Pamplona (Spain)

    2014-09-15

    Purpose: {sup 90}Y-microspheres are widely used for the radioembolization of metastatic liver cancer or hepatocellular carcinoma and there is a growing interest for imaging {sup 90}Y-microspheres with PET. The aim of this study is to evaluate the performance of a current generation PET/CT scanner for {sup 90}Y imaging and to optimize the PET protocol to improve the assessment and the quantification of {sup 90}Y-microsphere biodistribution after radioembolization. Methods: Data were acquired on a Biograph mCT-TrueV scanner with time of flight (TOF) and point spread function (PSF) modeling. Spatial resolution was measured with a{sup 90}Y point source. Sensitivity was evaluated using the NEMA 70 cm line source filled with {sup 90}Y. To evaluate the count rate performance, {sup 90}Y vials with activity ranging from 3.64 to 0.035 GBq were measured in the center of the field of view (CFOV). The energy spectrum was evaluated. Image quality with different reconstructions was studied using the Jaszczak phantom containing six hollow spheres (diameters: 31.3, 28.1, 21.8, 16.1, 13.3, and 10.5 mm), filled with a 207 kBq/ml {sup 90}Y concentration and a 5:1 sphere-to-background ratio. Acquisition time was adjusted to simulate the quality of a realistic clinical PET acquisition of a patient treated with SIR-Spheres{sup ®}. The developed methodology was applied to ten patients after SIR-Spheres{sup ®} treatment acquiring a 10 min per bed PET. Results: The energy spectrum showed the{sup 90}Y bremsstrahlung radiation. The {sup 90}Y transverse resolution, with filtered backprojection reconstruction, was 4.5 mm in the CFOV and degraded to 5.0 mm at 10 cm off-axis. {sup 90}Y absolute sensitivity was 0.40 kcps/MBq in the center of the field of view. Tendency of true and random rates as a function of the {sup 90}Y activity could be accurately described using linear and quadratic models, respectively. Phantom studies demonstrated that, due to low count statistics in {sup 90}Y PET

  13. Radio-synoviorthesis with yttrium 90 in the knee-joint in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Hagena, F.W.; Muenchen Univ.

    1982-01-01

    The radio-synoviorthesis with yttrium 90 in the knee-joint in rheumatoid arthritis was performed and controlled in 106 knees of patients with rheumatoid arthritis over a span of time between 6 and 49 months. The results are similar to those of other authors. As compared to synovectomy radio-synoviorthesis seems less successful as far as long-term results are concerned. As local treatment radio-synoviorthesis seems a good supplementory element in the therapeutic plan of rheumatoid arthritis. The indication to alternative procedures has been considered carefully for each individual case and joint. (orig.) [de

  14. Optimization of the contents of hollow glass microsphere and sodium hexametaphosphate for glass fiber vacuum insulation panel

    Science.gov (United States)

    Li, C. D.; Chen, Z. F.; Zhou, J. M.

    2016-07-01

    In this paper, various additive amounts of hollow glass microspheres (HGMs) and sodium hexametaphosphate (SHMP) powders were blended with flame attenuated glass wool (FAGW) to form hybrid core materials (HCMs) through the wet method. Among them, the SHMP was dissolved in the glass fiber suspension and coated on the surface of glass fibers while the HGMs were insoluble in the glass fiber suspension and filled in the fiber-fiber pores. The average pore diameter of the FAGW/HGM HCMs was 8-11 μm which was near the same as that of flame attenuated glass fiber mats (FAGMs, i.e., 10.5 µm). The tensile strength of the SHMP coated FAGMs was enhanced from 160 N/m to 370 N/m when SHMP content increased from 0 wt.% to 0.2 wt.%. By contrast, the tensile strength of the FAGW/HGM HCMs decreased from 160 N/m to 40 N/m when HGM content increased from 0 wt.% to 50 wt.%. Both the FAGW/HGM HCMs and SHMP coated FAGMs were vacuumed completely to form vacuum insulation panels (VIPs). The results showed that both the addition of SHMP and HGM led a slight increase in the thermal conductivity of the corresponding VIPs. To obtain a high-quality VIP, the optimal SHMP content and HGM content in glass fiber suspension was 0.12-0.2 wt.% and 0 wt.%.

  15. Use of Chelex-100 for selectively removing Y-90 from its parent Sr-90

    International Nuclear Information System (INIS)

    Huntley, M.W.

    1996-01-01

    A method for selectively removing yttrium-90 from its parent strontium-90 contained in an environmental sample includes loading the sample onto a column containing a chelating ion-exchange resin capable of retaining yttrium-90; washing the column with a solution capable of removing strontium, calcium, and other contaminants from the yttrium-90 fraction retained on the column; removing excess acetate salts from the column; eluting yttrium-90 solution from the column and adjusting the pH of this solution to about 2.7; filtering the yttrium-90 solution and weighing this solution for gravimetric yield; and, counting the yttrium-90 containing solution with a radiological counter for a time sufficient to achieve the statistical accuracy desired. It is preferred that the chelating ion-exchange resin is a ligand having the chemical name iminodiacetic acid mounted on a divinyl benzene substrate, converted from sodium form to ammonia form

  16. Radiopharmaceutical development based on human blood albumin microspheres and 90Y

    International Nuclear Information System (INIS)

    Petriev, V M; Vlasova, O P; Postnov, A A; Epstein, N B

    2017-01-01

    New radiopharmaceutial (RP) based on human serum albumin microspheres (MSA) and 90 Y was developed for treatment of liver cancer. The optimized synthesis using chelation resulted in approximately 80% yield with high specific activity. The RP developed was tested in mice with inoculated sarcoma-37. In two weeks the tumor size reduced by 43% after the treatment with the dose of 500 μCi injected into the tumor site. (paper)

  17. Effects of yttrium 90 on experimental allergic arthritis in rabbits

    International Nuclear Information System (INIS)

    Meier-Ruge, W.; Mueller, W.; Pavelka, K.

    1976-01-01

    Fifteen weeks after allergic arthritis developed in the knee joint of 17 immunized rabbits, 8 animals were given an injection of 200 μCi yttrium 90( 90 Y) into the left joint cavity and 7 were injected with 400 μCi. The animals were sacrificed at 2, 4, 8, 12, and 16 weeks, and at 6 to 12 months after the injection. Two uninjected animals used as morphological controls were sacrificed 13 weeks after immunization, and showed allergic arthritis had progressed to severe inflammation of the knee joint marked by massive round-cell infiltration, oedema, and proliferation of synovial mesothelium in the synovial villi and joint capsule. Treatment with 90 Y was effective 2 weeks after injection and the disappearance of inflammatory odema and marked regression of round-cell infiltration. This was accompanied by degeneration of the synovial mesothelium and fibrosis of the subsynovial tissue and synovial vessels as a secondary effect of the radiation. In the animals with severe allergic arthritis, the healing effects of 90 Y were more marked than the secondary effects of the radiation which were dose-dependent. Treatment with 90 Y of arthritic knee joints with the lowest effective dose of the isotope - if necessay with repeated application - seems justified. A single large dose does not have a greater therapeutic effect and causes more radiation damage to the joint. In view of the possible secondary effects in the joint, the indication for 90 Y therapy should be restricted, particularly in young patients, to cases of chronic relapsing arthritis unresponsive to other treatment. (U.K.)

  18. Effects of yttrium 90 on experimental allergic arthritis in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Meier-Ruge, W [Sandoz A.G., Basel (Switzerland); Mueller, W; Pavelka, K

    1976-02-01

    Fifteen weeks after allergic arthritis developed in the knee joint of 17 immunized rabbits, 8 animals were given an injection of 200 ..mu..Ci yttrium 90(/sup 90/Y) into the left joint cavity and 7 were injected with 400 ..mu..Ci. The animals were sacrificed at 2, 4, 8, 12, and 16 weeks, and at 6 to 12 months after the injection. Two uninjected animals used as morphological controls were sacrificed 13 weeks after immunization, and showed allergic arthritis had progressed to severe inflammation of the knee joint marked by massive round-cell infiltration, oedema, and proliferation of synovial mesothelium in the synovial villi and joint capsule. Treatment with /sup 90/Y was effective 2 weeks after injection and the disappearance of inflammatory odema and marked regression of round-cell infiltration. This was accompanied by degeneration of the synovial mesothelium and fibrosis of the subsynovial tissue and synovial vessels as a secondary effect of the radiation. In the animals with severe allergic arthritis, the healing effects of /sup 90/Y were more marked than the secondary effects of the radiation which were dose-dependent. Treatment with /sup 90/Y of arthritic knee joints with the lowest effective dose of the isotope - if necessay with repeated application - seems justified. A single large dose does not have a greater therapeutic effect and causes more radiation damage to the joint. In view of the possible secondary effects in the joint, the indication for /sup 90/Y therapy should be restricted, particularly in young patients, to cases of chronic relapsing arthritis unresponsive to other treatment.

  19. Spectrographic determination of strontium in yttrium-90 solutions; Determinacion espectrografica de estroncio en soluciones de itrio-90

    Energy Technology Data Exchange (ETDEWEB)

    Roca, M; Capdevila, C

    1970-07-01

    The copper spark method has been used for determining strontium in the concentration range 1-100 g/ml in yttrium-90 solutions containing 0,5 % or thereabouts of ammonium citrate. The influence of the citric acid as well as the ammonium citrate with regard to 2N HCL solutions has been studied: the citric acid enhances the line intensities of strontium. The employment of either barium or lanthanum as reference element compensates for this enhancement. Because of the increase in sensitivity mentioned above, the study of influence of the citric acid has been extended and several impurities usually determined in radioisotope solutions have been considered. (Author) 4 refs.

  20. WE-AB-204-02: Molecular-Imaging Based Assessment of Liver Complications for Yttrium-90 Microsphere Treatments: Can Existing NTCP Models Explain Clinical Outcomes?

    Energy Technology Data Exchange (ETDEWEB)

    Lin, M; Choi, E; Chuong, M; Saboury, B; Moeslein, F; D’Souza, W; Guerrero, M [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: To evaluate weather the current radiobiological models can predict the normal liver complications of radioactive Yttrium-90 ({sup 90}Y) selective-internal-radiation-treatment (SIRT) for metastatic liver lesions based on the post-infusion {sup 90}Y PET images. Methods: A total of 20 patients with metastatic liver tumors treated with SIRT that received a post-infusion {sup 90}Y-PET/CT scan were analyzed in this work. The 3D activity distribution of the PET images was converted into a 3D dose distribution via a kernel convolution process. The physical dose distribution was converted into the equivalent dose (EQ2) delivered at 2 Gy based on the linear-quadratic (LQ) model considering the dose rate effect. The biological endpoint of this work was radiation-induce liver disease (RILD). The NTCPs were calculated with four different repair-times (T1/2-Liver-Repair= 0,0.5,1.0,2.0 hr) and three published NTCP models (Lyman-external-RT, Lyman 90Y-HCC-SIRT, parallel model) were compared to the incidence of RILD of the recruited patients to evaluate their ability of outcome prediction. Results: The mean normal liver physical dose (avg. 51.9 Gy, range 31.9–69.8 Gy) is higher than the suggested liver dose constraint for external beam treatment (∼30 Gy). However, none of the patients in our study developed RILD after the SIRT. The estimated probability of ‘no patient developing RILD’ obtained from the two Lyman models are 46.3% to 48.3% (T1/2-Liver-Repair= 0hr) and <1% for all other repair times. For the parallel model, the estimated probability is 97.3% (0hr), 51.7% (0.5hr), 2.0% (1.0hr) and <1% (2.0hr). Conclusion: Molecular-images providing the distribution of {sup 90}Y enable the dose-volume based dose/outcome analysis for SIRT. Current NTCP models fail to predict RILD complications in our patient population, unless a very short repair-time for the liver is assumed. The discrepancy between the Lyman {sup 90}Y-HCC-SIRT model predicted and the clinically

  1. Y-90 microsphere therapy: prevention of adverse events.

    Science.gov (United States)

    Schultz, Cheryl C; Campbell, Janice; Bakalyar, Donovan; Beauvais, Michele; Feng, Wenzheng; Savin, Michael

    2009-08-01

    Thirty-three (33) events that were inconsistent with intended treatment for 471 Y-90 microsphere deliveries were analyzed from 2001 to 2007. Each occurrence was categorized, based on root-cause analysis, as a device/product defect and/or operator error event. Events were further categorized, if there was an adverse outcome, as spill/leak, termination, recatheterization, dose deviation, and/or a regulatory medical event. Of 264 Y-90 Therasphere (MDS Nordion, Ottawa, Ontario, Canada) treatments, 15 events were reported (5.7%). Of 207 Y-90 SIR-Spheres (Sirtex, Wilmington, MA) treatments, 18 events were reported (8.7%). Twenty-five (25) of 33 events (76%) were device/product defects: 73% for Therasphere (11 of 15) and 78% for SIR-Spheres (14 of 18). There were 31 adverse outcomes associated with 33 events: 15 were leaks and/or spills, 9 resulted in termination of the dose administration, 3 resulted in recatheterization for dose compensation, 2 were dose deviations (doses differing from the prescribed between 10% and 20%), and 2 were reported as regulatory medical events. Fifty-five (55) corrective actions were taken: 39 (71%) were related to the manufacturer and 16 (29%) were hospital based. This process of analyzing each event and measuring our outcomes has been effective at minimizing adverse events and improving patient safety.

  2. Development of phosphate glass microspheres containing holmium for selective internal radiotherapy; Desenvolvimento de microesferas de vidro fosfato contendo holmio para uso em radioterapia interna seletiva

    Energy Technology Data Exchange (ETDEWEB)

    Barros Filho, Eraldo Cordeiro

    2016-11-01

    The selective internal radiotherapy is an alternative for some kinds of cancer as the hepatocellular carcinoma (HCC) or primary liver cancer treatment. In this treatment, glass or polymer microspheres containing radionuclides inside their structure are introduced in the liver through hepatic artery and trapped at the arterioles that feed the tumor. In this work, the development of phosphate glasses containing holmium for production of microspheres and their application in Brazil are proposed. The developed glasses presented suitable chemical durability, density of 2,7(3) g/cm{sup 3}, high thermal stability and the impurities contained therein do not preclude the treatment. The microspheres were produced by the flame method and the gravitational fall method, and were characterized by means of several techniques to evaluate shape, average particle size, activity and biocompatibility suitable for selective internal radiotherapy. Based in the main results, the submission to in vivo tests is proposed. (author)

  3. Planar gamma camera imaging and quantitation of Yttrium-90 bremsstrahlung

    International Nuclear Information System (INIS)

    Shen, S.; DeNardo, G.L.; Yuan, A.

    1994-01-01

    Yttrium-90 is a promising radionuclide for radioimmunotherapy of cancer because of its energetic beta emissions. Therapeutic management requires quantitative imaging to assess the pharmacokinetics and radiation dosimetry of the 90 Y-labeled antibody. Conventional gamma photon imaging methods cannot be easily applied to imaging of 90 Y-bremsstrahlung because of its continuous energy spectrum. The sensitivity, resolution and source-to-background signal ratio (S/B) of the detector system for 90 Y-bremsstrahlung were investigated for various collimators and energy windows in order to determine optimum conditions for quantitative imaging. After these conditions were determined, the accuracy of quantitation of 90 Y activity in an Alderson abdominal phantom was examined. When the energy-window width was increased, the benefit of increased sensitivity outweighed degradation in resolution and S/B ratio until the manufacturer's energy specifications for the collimator were exceeded. Using the same energy window, the authors improved resolution and S/B for the medium-energy (ME) collimator when compared to the low-energy, all-purpose (LEAP) collimator, and there was little additional improvement using the high-energy (HE) collimator. Camera sensitivity under tissue equivalent conditions was 4.2 times greater for the LEAP and 1.7 times greater for the ME collimators when compared to the HE collimator. Thus, the best, most practical selections were found to be the ME collimator and an energy window of 55-285 keV. When they used these optimal conditions for image acquisition, the estimation of 90 Y activity in organs and tumors was within 15% of the true activities. The results for this study suggest that reasonable accuracy can be achieved in clinical radioimmunotherapy using 90 Y-bremsstrahlung quantitation. 28 refs., 5 figs., 7 tabs

  4. Radioactive impurities in radiopharmaceuticals with Y-90. Consequences for waste disposal; Radioaktive Verunreinigungen in Radiopharmazeutika mit Y-90. Konsequenzen fuer die Entsorgung von Reststoffen

    Energy Technology Data Exchange (ETDEWEB)

    Wanke, C.; Solle, A.; Geworski, L. [Medizinische Hochschule Hannover (Germany). Stabsstelle Strahlenschutz und Abt. Medizinische Physik

    2016-07-01

    Y-90 plays an important role in nuclear medicine and is of particular interest in radiation synovectomy (RSO) and in Selective internal radiation therapy (SIRT). Longer-lived impurities were investigated in a pharmaceutical used in RSO and in glass microspheres applied for SIRT. For this, measurements were carried out to identify gamma-emitting impurities. Especially in the late measurements, after decay of Y-90, impurities such as Y-88 and Y-91, Zn-65, Eu-152, Gd-153, Tb-160 und Yb-169 were identified, which accounted for less than 0,01 % of the total radioactivity at the calibration date, so that all pharmaceutical requirements were met. The impurities, however, have to be taken into account in waste management and clearance. Assuming typical masses, waste from RSO can undergo unrestricted clearance based on the clearance values tabulated in the German Radiation Protection Ordinance, provided sufficient decay storage. For waste from SIRT with glass microspheres, however, other clearance or disposal options have to be found.

  5. Metallic coating of microspheres

    International Nuclear Information System (INIS)

    Meyer, S.F.

    1980-01-01

    Extremely smooth, uniform metal coatings of micrometer thicknesses on microscopic glass spheres (microspheres) are often needed as targets for inertial confinement fusion (ICF) experiments. The first part of this paper reviews those methods used successfully to provide metal coated microspheres for ICF targets, including magnetron sputtering, electro- and electroless plating, and chemical vapor pyrolysis. The second part of this paper discusses some of the critical aspects of magnetron sputter coating of microspheres, including substrate requirements, the sticking of microspheres during coating (preventing a uniform coating), and the difficulties in growing the desired dense, smooth, uniform microstructure on continuously moving spherical substrates

  6. Efficacy and safety of selective internal radiotherapy with yttrium-90 resin microspheres compared with sorafenib in locally advanced and inoperable hepatocellular carcinoma (SARAH): an open-label randomised controlled phase 3 trial.

    Science.gov (United States)

    Vilgrain, Valérie; Pereira, Helena; Assenat, Eric; Guiu, Boris; Ilonca, Alina Diana; Pageaux, Georges-Philippe; Sibert, Annie; Bouattour, Mohamed; Lebtahi, Rachida; Allaham, Wassim; Barraud, Hélène; Laurent, Valérie; Mathias, Elodie; Bronowicki, Jean-Pierre; Tasu, Jean-Pierre; Perdrisot, Rémy; Silvain, Christine; Gerolami, René; Mundler, Olivier; Seitz, Jean-Francois; Vidal, Vincent; Aubé, Christophe; Oberti, Frédéric; Couturier, Olivier; Brenot-Rossi, Isabelle; Raoul, Jean-Luc; Sarran, Anthony; Costentin, Charlotte; Itti, Emmanuel; Luciani, Alain; Adam, René; Lewin, Maïté; Samuel, Didier; Ronot, Maxime; Dinut, Aurelia; Castera, Laurent; Chatellier, Gilles

    2017-12-01

    Sorafenib is the recommended treatment for patients with advanced hepatocellular carcinoma. We aimed to compare the efficacy and safety of sorafenib to that of selective internal radiotherapy (SIRT) with yttrium-90 ( 90 Y) resin microspheres in patients with hepatocellular carcinoma. SARAH was a multicentre, open-label, randomised, controlled, investigator-initiated, phase 3 trial done at 25 centres specialising in liver diseases in France. Patients were eligible if they were aged at least 18 years with a life expectancy greater than 3 months, had an Eastern Cooperative Oncology Group (ECOG) performance status of 0 or 1, Child-Pugh liver function class A or B score of 7 or lower, and locally advanced hepatocellular carcinoma (Barcelona Clinic Liver Cancer [BCLC] stage C), or new hepatocellular carcinoma not eligible for surgical resection, liver transplantation, or thermal ablation after a previously cured hepatocellular carcinoma (cured by surgery or thermoablative therapy), or hepatocellular carcinoma with two unsuccessful rounds of transarterial chemoembolisation. Patients were randomly assigned (1:1) by a permutated block method with block sizes two and four to receive continuous oral sorafenib (400 mg twice daily) or SIRT with 90 Y-loaded resin microspheres 2-5 weeks after randomisation. Patients were stratified according to randomising centre, ECOG performance status, previous transarterial chemoembolisation, and presence of macroscopic vascular invasion. The primary endpoint was overall survival. Analyses were done on the intention-to-treat population; safety was assessed in all patients who received at least one dose of sorafenib or underwent at least one of the SIRT work-up exams. This study has been completed and the final results are reported here. The trial is registered with ClinicalTrials.gov, number NCT01482442. Between Dec 5, 2011, and March 12, 2015, 467 patients were randomly assigned; after eight patients withdrew consent, 237 were assigned to

  7. Y-90 microspheres in the treatment of unresectable hepatocellularcarcinoma

    International Nuclear Information System (INIS)

    Al-Kalbani, A.; Kamel, Y.

    2008-01-01

    A small percentage of patients with hepatocellular carcinoma (HCC) arecandidates for curative treatment in form of resection or transplantation.There are different treatment options for unresectable HCC-like localablative therapies and recently systemic therapy with Sorafenib. All of thesehave variable response rate and had been proven to improve survival. In thelast few years, there is a growing interest in TheraSphere radioembolization.It consists of yttrium (Y-90) embedded into nonbiodegradeable glassmicrospheres. It is selectively administered by intraarterial hepaticinjection giving high doses of radiation to the tumor and sparing the liverparenchyma. It has been shown to improve survival and used as a bridge totransplantation and to downstage tumors for resection. Therasphere seems tohave favorable safety profile and has been used in patients with portal veinthrombosis with successful outcome. (author)

  8. Personnel dose reduction in 90Y microspheres liver-directed radioembolization: from interventional radiology suite to patient ward.

    Science.gov (United States)

    Law, Martin; Wong, K K; Tso, W K; Lee, Victor; Luk, M Y; Tong, C C; Chu, Ferdinand

    2017-03-01

    To describe a method to reduce the external radiation exposure emitted from the patient after liver-directed radioembolization using 90 Y glass microspheres, to quantitatively estimate the occupational dose of medical personnel providing patient care to the patient radioembolized with the use of the method and to discuss radiation exposure to patients who are adjacent if the patient radioembolized needs hospitalization. A lead-lined blanket of lead equivalence of 0.5 mm was used to cover the patient abdomen immediately after the 90 Y radioembolization procedure, in order to reduce the radiation emitted from the patient. The interventional radiologist used a rod-type puncture site compressor for haemostasis to avoid direct contact with possible residual radioactivity at the puncture site. Dose rates were measured at the interventional radiologist chest and hand positions during puncture site pressing for haemostasis with and without the use of the blanket. The measurement results were applied to estimate the occupational dose of colleagues performing patient care to the patient radioembolized. The exposure to patients adjacent in the ward was estimated if the patient radioembolized was hospitalized. The radiation exposures measured at the radiologist chest and hand positions have been significantly reduced with the lead-lined blanket in place. The radiologist, performing puncture site pressing at the end of radioembolization procedure, would receive an average hand dose of 1.95 μSv and body dose under his own lead apron of 0.30 μSv for an average 90 Y microsphere radioactivity of 2.54 GBq. Other medical personnel, nurses and porters, would receive occupational doses corresponding to an hour of background radiation. If the patient radioembolized using 90 Y needs hospitalization in a common ward, using the lead-lined blanket to cover the abdomen of the patient and keeping a distance of 2 m from the patient who is adjacent would reduce the exposure by 0

  9. Dissolution of lanthanide alumino-silicate oxynitride glasses

    Science.gov (United States)

    Bois, L.; Barré, N.; Guillopé, S.; Guittet, M. J.; Gautier-Soyer, M.; Duraud, J. P.; Trocellier, P.; Verdier, P.; Laurent, Y.

    2000-01-01

    The aqueous corrosion behavior of lanthanide aluminosilicate glasses has been studied under static conditions ( T=96°C, duration=1 and 3 months, glass surface area/leachate volume, S/ V=0.3 cm -1) by means of solution and solid analyses. It was found that these glasses exhibit a high chemical durability. The influence of yttrium, magnesium and nitrogen, which are supposed to improve the mechanical properties, on the chemical durability, has been investigated. After a one-month experiment, lanthanum and yttrium releases were found to be about 10 -7 mol l -1, while silicon and aluminum releases were about 10 -5 mol l -1. Yttrium seems to improve the chemical durability. The presence of nitrogen does not seem to modify the glass constituents releases, but seems to improve the surface state of the altered glass. XPS experiments reveal that lanthanum and yttrium are more concentrated near the surface (20-30 Å) of the glass after the leaching test.

  10. Effectiveness of quantitative MAA SPECT/CT for the definition of vascularized hepatic volume and dosimetric approach: phantom validation and clinical preliminary results in patients with complex hepatic vascularization treated with yttrium-90-labeled microspheres.

    Science.gov (United States)

    Garin, Etienne; Lenoir, Laurence; Rolland, Yan; Laffont, Sophie; Pracht, Marc; Mesbah, Habiba; Porée, Philippe; Ardisson, Valérie; Bourguet, Patrick; Clement, Bruno; Boucher, Eveline

    2011-12-01

    The goal of this study was to assess the use of quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) analysis for vascularized volume measurements in the use of the yttrium-90-radiolabeled microspheres (TheraSphere). A phantom study was conducted for the validation of SPECT/CT volume measurement. SPECT/CT quantitative analysis was used for the measurement of the volume of distribution of the albumin macroaggregates (MAA; i.e., the vascularized volume) in the liver and the tumor, and the total activity contained in the liver and the tumor in four consecutive patients presenting with a complex liver vascularization referred for a treatment with TheraSphere. SPECT/CT volume measurement proved to be accurate (mean error <7%) and reproducible (interobserver concordance 0.99). For eight treatments, in cases of complex hepatic vascularization, the hepatic volumes based on angiography and CT led to a relative overestimation or underestimation of the vascularized hepatic volume by 43.2 ± 32.7% (5-87%) compared with SPECT/CT analyses. The vascularized liver volume taken into account calculated from SPECT/CT data, instead of angiography and CT data, results in modifying the activity injected for three treatments of eight. Moreover, quantitative analysis of SPECT/CT allows us to calculate the absorbed dose in the tumor and in the healthy liver, leading to doubling of the injected activity for one treatment of eight. MAA SPECT/CT is accurate for volume measurements. It provides a valuable contribution to the therapeutic planning of patients presenting with complex hepatic vascularization, in particular for calculating the vascularized liver volume, the activity to be injected and the absorbed doses. Studies should be conducted to assess the role of quantitative MAA/SPECT CT in therapeutic planning.

  11. Low threshold lasing of bubble-containing glass microspheres by non-whispering gallery mode excitation over a wide wavelength range

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Tsutaru, E-mail: kumagai.t.af@m.titech.ac.jp; Kishi, Tetsuo; Yano, Tetsuji [Department of Chemistry and Materials Science, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan)

    2015-03-21

    Bubble-containing Nd{sup 3+}-doped tellurite glass microspheres were fabricated by localized laser heating technique to investigate their optical properties for use as microresonators. Fluorescence and excitation spectra measurements were performed by pumping with a tunable CW-Ti:Sapphire laser. The excitation spectra manifested several sharp peaks due to the conventional whispering gallery mode (WGM) when the pumping laser was irradiated to the edge part of the microsphere. However, when the excitation light was irradiated on the bubble position inside the microsphere, “non-WGM excitation” was induced, giving rise to numerous peaks at a broad wavelength range in the excitation spectra. Thus, efficient excitation was achieved over a wide wavelength range. Lasing threshold excited at the bubble position was much lower than that for the excitation at the edges of the microsphere. The lowest value of the laser threshold was 34 μW for a 4 μm sphere containing a 0.5 μm bubble. Efficiency of the excitation at the bubble position with broadband light was calculated to be 5 times higher than that for the edge of the microsphere. The bubble-containing microsphere enables efficient utilization of broadband light excitation from light-emitting diodes and solar light.

  12. Biodistribution And Preclinical Test Of P-32 Glass Microspheres For Cancer Therapy

    International Nuclear Information System (INIS)

    A, Laksmi; C, Djoharly; P, Ratlan; W, Widyastuti; Purwoko; Bagiwati, Sri; Setiyowati, Sri; Abidin; Sri, Aguswarini

    2003-01-01

    The superiority of radiopharmaceutical compare to the other techniques of medical services, especially for diagnosis and therapy of several deadly diseases such as cancer, shows that this technique is more specific and accurate. P-32-Glass microsphere (P-32 GMS) is one of the radiopharmaceuticals developed recently for therapy using internal radiation method for several malignant cancers, such as hepatic cancer. The P-32 GMS was prepared by irradiating P-31 GMS with neutron at a nuclear reactor, then the preparation was injected to the cancerous infected area. To make easy injection, it needs suspension agent that was including PVP, dextrose and saline with a composition of 16% PVP - 50% dextrose - saline as 2 : 3 : 3 (v/v/v). As microsphere size should be maintained at 40-60 μm, the injection needle was selected properly in order to remain the particle size of P-32 GMS unchanged when the friction occurs between microspheres and the inside surfaces of the needle. The injection needle used was needle produced by BD with a typical size of 20 G1 Tw. Biodistribution studies were carried out after 1, 3, 5 and 24 hour of injection. Experimental results for 1, 3 and 24 hour post-injection studies showed that 100% activity of P-32 GMS was accumulated at the injected area. For 5 hour post-injection study, accumulation of P-32 GMS activity was also found at stomach besides the injected area, but it was presumed as working error

  13. Minimizing resputtering of Pt-coated microspheres in a batch magnetron sputtering process

    International Nuclear Information System (INIS)

    Plake, A.L.

    1981-01-01

    Preventing DT loss from glass microspheres being smoothly coated with PT is needed during fabrication of laser fusion targets. Evidence indicates that the increase of substrate temperature due to resputtering will cause DT loss. Resputtering will prevent a smooth and uniform coating on these glass microspheres (140 μm in diameter). This paper reviews the method that was developed to find a set of coating conditions to minimize the DT loss, and still be able to produce thick smooth Pt coated glass microspheres

  14. Assessing Intra-arterial Complications of Planning and Treatment Angiograms for Y-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Osman, E-mail: osman1423@gmail.com [Rush University Medical Center, Section of Interventional Radiology, Department of Radiology (United States); Patel, Mikin V. [University of Chicago, Department of Radiology (United States); Masrani, Abdulrahman; Chong, Bradford; Osman, Mohammed; Tasse, Jordan; Soni, Jayesh; Turba, Ulku Cenk; Arslan, Bulent [Rush University Medical Center, Section of Interventional Radiology, Department of Radiology (United States)

    2017-05-15

    PurposeTo report hepatic arterial-related complications encountered during planning and treatment angiograms for radioembolization and understand any potential-associated risk factors.Materials and Methods518 mapping or treatment angiograms for 180 patients with primary or metastatic disease to the liver treated by Yttrium-90 radioembolization between 2/2010 and 12/2015 were retrospectively reviewed. Intra-procedural complications were recorded per SIR guidelines. Patient demographics, indication for treatment, prior exposure to chemotherapeutic agents, operator experience, and disease burden were reviewed. Technical variables including type of radioembolic (glass vs. resin microspheres), indication for angiography (mapping vs. treatment), variant anatomy, and attempts at coil embolization were also assessed.ResultsThirteen (13/518, 2.5%) arterial-related complications occurred in 13 patients. All but two complications resulted during transcatheter coil embolization to prevent non-target embolization. Complications included coil migration (n = 6), arterial dissection (n = 2), focal vessel perforation (n = 2), arterial thrombus (n = 2), and vasospasm prohibiting further arterial sub-selection (n = 1). Transarterial coiling was identified as a significant risk factor of complications on both univariate and multivariate regression analysis (odds ratio 7.8, P = 0.004). Usage of resin microspheres was also a significant risk factor (odds ratio 9.5, P = 0.042). No other technical parameters or pre-procedural variables were significant after adjusting for confounding on multivariate analysis (P > 0.05).ConclusionIntra-procedural hepatic arterial complications encountered during radioembolization were infrequent but occurred mainly during coil embolization to prevent non-target delivery to extra-hepatic arteries.

  15. A dosimetric treatment planning strategy in radioembolization of hepatocarcinoma with 90Y glass microspheres.

    Science.gov (United States)

    Chiesa, C; Mira, M; Maccauro, M; Romito, R; Spreafico, C; Sposito, C; Bhoori, S; Morosi, C; Pellizzari, S; Negri, A; Civelli, E; Lanocita, R; Camerini, T; Bampo, C; Carrara, M; Seregni, E; Marchianò, A; Mazzaferro, V; Bombardieri, E

    2012-12-01

    Our goal was to limit liver toxicity and to obtain good efficacy by developing a dosimetric treatment planning strategy. While several dosimetric evaluations are reported in literature, the main problem of the safety of the treatment is rarely addressed. Our work is the first proposal of a treatment planning method for glass spheres, including both liver toxicity and efficacy issues. Fifty-two patients (series 1) had been treated for intermediated/advanced hepatocellular carcinoma (HCC) with glass spheres, according to the Therasphere® prescription of 120 Gy averaged on the injected lobe. They were retrospectively evaluated with voxel dosimetry, adopting the local deposition hypothesis. Regions of interest on tumor and non tumor parenchyma were drawn to determine the parenchyma absorbed dose, averaged also on non irradiated voxels, excluding tumor voxels. The relationship between the mean non tumoral parenchyma absorbed dose D and observed liver decompensation was analyzed. Basal Child-Pugh strongly affected the toxicity incidence, which was 22% for A5, 57% for A6, 89% for B7 patients. Restricting the analysis to our numerically richest class (basal Child-Pugh A5 patients), D median values were significantly different between toxic (median 90 Gy) and non toxic treatments (median 58 Gy) at a Mann-Withney test, (P=0.033). Using D as a marker for toxicity, the separation of the two populations in terms of area under ROC curve was 0.75, with 95% C.I. of [0.55-0.95]. The experimental Normal Tissue Complication Probability (NTCP) curve as a function of D resulted in the following values: 0%, 14%, 40%, 67% for D interval of [0-35] Gy, [35-70] Gy, [70-105] Gy, [105-140] Gy. A limit of about 70 Gy for the mean absorbed dose to parenchyma was assumed for A5 patients, corresponding to a 14% risk of liver decompensation. This result is applicable only to our administration conditions: glass spheres after a decay interval of 3.75 days. Different safety limit (40 Gy) are

  16. An assessment of glass microspheres for use as number-based aerodynamic size standards

    International Nuclear Information System (INIS)

    Ball, M.H.E.; Marshall, I.A.; Mitchell, J.P.; Rideal, G.

    1989-08-01

    Polydisperse, non-porous microspheres are required with well-defined aerodynamic properties to determine if enhanced settling of micron-sized aerosol particles occurs in the presence of larger particles (gravitational agglomeration). Glass spheres with claimed unimodal narrow distributions were evaluated using a TSI Aerodynamic Particle Sizer (APS33B). The size fractions containing particles in the range from 1 to 5 μm aerodynamic diameter were truly unimodal, but the fractions which were supposed to consist solely of particles larger than 5 μm aerodynamic diameter contained a significant proportion of submicron particles. (author)

  17. Biocompatibility, Inflammatory Response, and Recannalization Characteristics of Nonradioactive Resin Microspheres: Histological Findings

    International Nuclear Information System (INIS)

    Bilbao, Jose I.; Martino, Alba de; Luis, Esther de; Diaz-Dorronsoro, Lourdes; Alonso-Burgos, Alberto; Martinez de la Cuesta, Antonio; Sangro, Bruno; Garcia de Jalon, Jose A.

    2009-01-01

    Intra-arterial radiotherapy with yttrium-90 microspheres (radioembolization) is a therapeutic procedure exclusively applied to the liver that allows the direct delivery of high-dose radiation to liver tumors, by means of endovascular catheters, selectively placed within the tumor vasculature. The aim of the study was to describe the distribution of spheres within the precapillaries, inflammatory response, and recannalization characteristics after embolization with nonradioactive resin microspheres in the kidney and liver. We performed a partial embolization of the liver and kidney vessels in nine white pigs. The left renal and left hepatic arteries were catheterized and filled with nonradioactive resin microspheres. Embolization was defined as the initiation of near-stasis of blood flow, rather than total occlusion of the vessels. The hepatic circulation was not isolated so that the effects of reflux of microspheres into stomach could be observed. Animals were sacrificed at 48 h, 4 weeks, and 8 weeks, and tissue samples from the kidney, liver, lung, and stomach evaluated. Microscopic evaluation revealed clusters of 10-30 microspheres (15-30 μm in diameter) in the small vessels of the kidney (the arciform arteries, vasa recti, and glomerular afferent vessels) and liver. Aggregates were associated with focal ischemia and mild vascular wall damage. Occlusion of the small vessels was associated with a mild perivascular inflammatory reaction. After filling of the left hepatic artery with microspheres, there was some evidence of arteriovenous shunting into the lungs, and one case of cholecystitis and one case of marked gastritis and ulceration at the site of arterial occlusion due to the presence of clusters of microspheres. Beyond 48 h, microspheres were progressively integrated into the vascular wall by phagocytosis and the lumen recannalized. Eight-week evaluation found that the perivascular inflammatory reaction was mild. Liver cell damage, bile duct injury, and

  18. Dynamic colour and utilizable white fluorescence from Eu/Tb ions codoped lithium-yttrium-aluminium-silicate glasses

    International Nuclear Information System (INIS)

    Shen Lifan; Liu Xiao; Chen Baojie; Lin Hai; Pun, Edwin Yue Bun

    2012-01-01

    A group of dynamic-colour white fluorescences with various colour temperatures that can be applied to circadian lighting are achieved in Eu/Tb-codoped lithium-yttrium-aluminium-silicate (LYAS) glasses, which can be attributed to the simultaneous generation of three primary colours emitting from Eu 3+ (red), Eu 2+ (blue) and Tb 3+ (green) by varying the ultraviolet (UV) radiation wavelength. Fluorescence colour coordinates pass through the whole white region of the CIE x, y chromaticity diagram when the UV excitation wavelength is increased from 300 to 370 nm. A favourable white light with colour coordinates (0.338, 0.298) close to the equal energy white is obtained under 360 nm excitation. These results indicate that the Eu/Tb-codoped LYAS glasses are a promising candidate to develop white lighting devices under the excitation of commercial UV light-emitting diodes, and a smart lighting system based on rare-earth doped glasses will be a potential illumination source offering controllability of the colour temperature that can adjust to specific environments and requirements, and benefit human health, well-being and productivity. (paper)

  19. Magnetic propulsion of microspheres at liquid-glass interfaces

    Science.gov (United States)

    Helgesen, Geir

    2018-02-01

    Bio-coated, magnetic microspheres have many applications in biotechnology and medical technology as a tool to separate and extract cells or molecules in a water solution by applying external strong magnetic field gradients. However, magnetic microspheres with or without attached cargo can also be separated in the liquid solution if they are exposed to alternating or rotating, relatively weak magnetic fields. Microspheres that have a higher density than the liquid will approach the bottom surface of the sample cell, and then a combination of viscous and surface frictional forces can propel the magnetic microspheres along the surface in a direction perpendicular to the axis of field rotation. Experiments demonstrating this type of magnetic propulsion are shown, and the forces active in the process are discussed. The motion of particles inside sample cells that were tilted relative to the horizontal direction was studied, and the variation of propulsion velocity as a function of tilt angle was used to find the values of different viscous and mechanical parameters of motion. Propulsion speeds of up to 5 μm/s were observed and were found to be caused by a partly rolling and partly slipping motion of rotating microspheres with a slipping coefficient near 0.6.

  20. Intra-arterial treatment with 90Y microspheres for hepatocellular carcinoma: 4 years experience at the Ghent University Hospital

    International Nuclear Information System (INIS)

    Lambert, Bieke; Mertens, Jeroen; Oltenfreiter, Ruth; Sturm, Emiel; Defreyne, Luc; Smeets, Peter; Troisi, Roberto; Vlierberghe, Hans van

    2011-01-01

    We report on our experience in terms of eligibility, safety, response and survival for treatment of hepatocellular carcinoma (HCC) with 90 Y microspheres. Secondly, we investigated the urinary excretion of 90 Y following treatment. We retrospectively reviewed all HCC patients referred to our department for 90 Y microsphere treatment. We recorded reasons for not proceeding to actual treatment. In case treatment was performed, we assessed the tolerance (Common Terminology Criteria for Adverse Events v3.0, CTCAE v3.0), the response [modified Response Evaluation Criteria in Solid Tumors (mRECIST) criteria] and long-term survival (Kaplan-Meier). The urinary excretion was estimated by 12-h urine collections post-injection for analysis in a gamma counter. Forty-three HCC patients were referred for radioembolization. Fourteen patients were excluded, mainly due to unfavourable 99m Tc-macroaggregated albumin (MAA) distribution. Twenty-nine patients were treated with 90 Y microspheres (TheraSphere, mean activity 2.17 GBq). In four patients severe clinical adverse events were encountered, however only in one case clearly related to the therapy. Twenty patients were assessable by mRECIST: complete response in 15%, partial response in 35%, stable disease in 30% and progression in 20% were observed. A median survival of 12.3 months (95% confidence interval 9.4-15.2) was estimated. Concerning the substudy on urinary excretion, only 0.0025% of the administered activity was excreted in the urine within the first 12 h following TheraSphere. Following a strict workup before admitting patients to radioembolization with TheraSphere, we found good clinical tolerance in the vast majority of patients. Radiological response assessment yielded an overall response rate of 50%, when evaluated early following treatment. Urine analysis showed consistently only low activities of 90 Y excreted in the urine. (orig.)

  1. Gastric injury from 90Y to left hepatic lobe tumors adjacent to the stomach: fact or fiction?

    International Nuclear Information System (INIS)

    Gates, Vanessa L.; Hickey, Ryan; Marshall, Karen; Williams, Melissa; Salzig, Krystina; Lewandowski, Robert J.; Salem, Riad

    2015-01-01

    Radioembolization with 90 Y microspheres is a locoregional radiation therapy for unresectable hepatic neoplasm. Non-target delivery of 90 Y microspheres resulting in gastrointestinal (GI) symptoms is a recognized complication; there is minimal knowledge regarding the radiation effect to the gastric wall from left hepatic lobe 90 Y treatments. Our aim was to study the incidence of GI complications when the target tissue (hepatic parenchyma ± tumor) is in close proximity to the gastric wall. We hypothesized that liver (tumor) to stomach proximity does not correlate with increased toxicity. Between November 2011 and September 2013, we studied all patients who underwent left lobe radioembolization with 90 Y glass microspheres. With Institutional Review Board (IRB) approval, we retrospectively reviewed MRI/CT images of these patients, identifying a subset of patients with the left hepatic lobe <1 cm from the gastric wall. Patients were seen in clinic 1 month posttreatment and subsequently at 3-month intervals. Short- and long-term gastric adverse events were tabulated. Ninety-seven patients successfully underwent left hepatic lobe 90 Y microsphere radioembolization in which the average distance from the liver to the stomach wall was 1.0 ± 2.8 mm. The average dose for patients who received radioembolization to the left hepatic lobe was 109 ± 57 Gy. Fifty patients had tumor within 1 cm of the gastric wall. The average dose for patients who received radioembolization to the left hepatic lobe with tumor within 1 cm of the gastric wall was 121 ± 41 Gy. There were no reportable or recordable medical events. Of the patients, 34 % reported abdominal pain that was grade 1-2; 65 % of the patients reported no abdominal pain. None of the 97 patients developed a clinically evident GI ulcer. Patients with left lobe tumors adjacent to or abutting the stomach do not exhibit acute or chronic radiation effects following radioembolization with glass microspheres. (orig.)

  2. Increasing sensitivity and angle-of-view of mid-wave infrared detectors by integration with dielectric microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Allen, Kenneth W., E-mail: kenneth.allen@gtri.gatech.edu; Astratov, Vasily N., E-mail: astratov@uncc.edu [Department of Physics and Optical Science, Center for Optoelectronics and Optical Communications, University of North Carolina at Charlotte, Charlotte, North Carolina 28223-0001 (United States); Air Force Research Laboratory, Sensors Directorate, Wright Patterson AFB, Ohio 45433 (United States); UES, Dayton, Ohio 45433 (United States); Abolmaali, Farzaneh [Department of Physics and Optical Science, Center for Optoelectronics and Optical Communications, University of North Carolina at Charlotte, Charlotte, North Carolina 28223-0001 (United States); Duran, Joshua M.; Ariyawansa, Gamini; Limberopoulos, Nicholaos I. [Air Force Research Laboratory, Sensors Directorate, Wright Patterson AFB, Ohio 45433 (United States); Urbas, Augustine M. [Air Force Research Laboratory, Materials and Manufacturing Directorate, Wright-Patterson AFB, Ohio 45433 (United States)

    2016-06-13

    We observed up to 100 times enhancement of sensitivity of mid-wave infrared photodetectors in the 2–5 μm range by using photonic jets produced by sapphire, polystyrene, and soda-lime glass microspheres with diameters in the 90–300 μm range. By finite-difference time-domain (FDTD) method for modeling, we gain insight into the role of the microspheres refractive index, size, and alignment with respect to the detector mesa. A combination of enhanced sensitivity with angle-of-view (AOV) up to 20° is demonstrated for individual photodetectors. It is proposed that integration with microspheres can be scaled up for large focal plane arrays, which should provide maximal light collection efficiencies with wide AOVs, a combination of properties highly attractive for imaging applications.

  3. Yttrium synovectomy: a meta-analysis of the literature

    International Nuclear Information System (INIS)

    Jones, G.

    1993-01-01

    Yttrium synovectomy for chronic synovitis of the knee enjoys widespread usage in Australia with approximately 400 patients receiving yttrium-90 in 1991. Despite abundant anecdotal evidence of its efficacy there is a paucity of controlled trials and those that have been done have produced conflicting results and have been of insufficient sample size. To critically and quantitatively evaluate the published English literature on comparative trials of yttrium-90 therapy for chronic synovitis of the knee, the technique of meta-analysis was utilised. The literature search was carried out using the MeSH terms of synovectomy and knee; and yttrium. This was augmented by referring to reviews, current textbooks and back-references. Outcome measures varied between trials but could be grouped as treatment success. The Peto modification of Mantel and Haenszl was used for statistical pooling of data yielding a pooled odds ratio (OR). The literature search revealed ten controlled trials of which two were excluded from further analysis. It was found that yttrium was superior to placebo (OR 2.42, 95% CI 1.02-5.73) but it is recommended that this result should be interpreted with caution due to possible publication bias. It is concluded that there is insufficient evidence from comparative trials of yttrium in the English literature to show that yttrium synovectomy is convincingly superior to triamcinolone (OR 1.89, 95% CI 0.81-10.55) or other active modalities (OR 1.04, 95% CI 0.72-1.52). 25 refs., 4 tabs

  4. NUMERICAL ESTIMATION OF EFFECTIVE ELASTIC MODULI OF SYNTACTIC FOAMS REINFORCED BY SHORT GLASS FIBERS

    Directory of Open Access Journals (Sweden)

    Wei Yu

    2016-03-01

    Full Text Available The mechanical properties of hollow glass microsphere/epoxy resin syntactic foams reinforced by short glass fibers are studied using representative volume elements. Both the glass fibers and the hollow glass microspheres exhibit random arrangement in the epoxy resin. The volume fraction and wall thickness of hollow glass microspheres and the volume fraction of glass fibers are considered as parameters. It is observed that the elastic modulus values of syntactic foams decrease with the increase of microsphere volume fraction when the microsphere relative wall thickness is lower. However, it increases with the increase of microsphere volume fraction when the relative wall thickness exceeds a critical value. The elastic modulus value goes through a maximum when the relative wall thickness is around 0.06 at 25 % volume fraction of microspheres. The addition of glass fibers reduces the critical wall thickness values of the microspheres and increases the mechanical properties of the composites. The highest stress lies on the equatorial plane perpendicular to the loading direction. Adding fibers reduces the large stress distribution areas on the microspheres, and the fibers aligned with the loading direction play an important load-bearing role.

  5. Intra-arterial treatment with {sup 90}Y microspheres for hepatocellular carcinoma: 4 years experience at the Ghent University Hospital

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, Bieke; Mertens, Jeroen; Oltenfreiter, Ruth [Ghent University Hospital, Department of Nuclear Medicine, Ghent (Belgium); Sturm, Emiel; Defreyne, Luc [Ghent University Hospital, Department of Vascular and Interventional Radiology, Ghent (Belgium); Smeets, Peter [Ghent University Hospital, Department of Radiology, Ghent (Belgium); Troisi, Roberto [Ghent University Hospital, Department of Hepatobiliary Surgery and Liver Transplantation, Ghent (Belgium); Vlierberghe, Hans van [Ghent University Hospital, Department of Gastroenterology and Hepatology, Ghent (Belgium)

    2011-12-15

    We report on our experience in terms of eligibility, safety, response and survival for treatment of hepatocellular carcinoma (HCC) with {sup 90}Y microspheres. Secondly, we investigated the urinary excretion of {sup 90}Y following treatment. We retrospectively reviewed all HCC patients referred to our department for {sup 90}Y microsphere treatment. We recorded reasons for not proceeding to actual treatment. In case treatment was performed, we assessed the tolerance (Common Terminology Criteria for Adverse Events v3.0, CTCAE v3.0), the response [modified Response Evaluation Criteria in Solid Tumors (mRECIST) criteria] and long-term survival (Kaplan-Meier). The urinary excretion was estimated by 12-h urine collections post-injection for analysis in a gamma counter. Forty-three HCC patients were referred for radioembolization. Fourteen patients were excluded, mainly due to unfavourable {sup 99m}Tc-macroaggregated albumin (MAA) distribution. Twenty-nine patients were treated with {sup 90}Y microspheres (TheraSphere, mean activity 2.17 GBq). In four patients severe clinical adverse events were encountered, however only in one case clearly related to the therapy. Twenty patients were assessable by mRECIST: complete response in 15%, partial response in 35%, stable disease in 30% and progression in 20% were observed. A median survival of 12.3 months (95% confidence interval 9.4-15.2) was estimated. Concerning the substudy on urinary excretion, only 0.0025% of the administered activity was excreted in the urine within the first 12 h following TheraSphere. Following a strict workup before admitting patients to radioembolization with TheraSphere, we found good clinical tolerance in the vast majority of patients. Radiological response assessment yielded an overall response rate of 50%, when evaluated early following treatment. Urine analysis showed consistently only low activities of {sup 90}Y excreted in the urine. (orig.)

  6. Yttrium-90 Radioembolization for Unresectable Standard-chemorefractory Intrahepatic Cholangiocarcinoma: Survival, Efficacy, and Safety Study

    Energy Technology Data Exchange (ETDEWEB)

    Rafi, Shoaib; Piduru, Sarat M. [Emory University School of Medicine, Division of Interventional Radiology and Image Guided Medicine, Department of Radiology (United States); El-Rayes, Bassel; Kauh, John S. [Emory University School of Medicine, Department of Hematology and Medical Oncology (United States); Kooby, David A.; Sarmiento, Juan M. [Emory University School of Medicine, Department of Surgical Oncology in Surgery (United States); Kim, Hyun S., E-mail: kevin.kim@emory.edu [Emory University School of Medicine, Division of Interventional Radiology and Image Guided Medicine, Department of Radiology (United States)

    2013-04-15

    To assess the overall survival, efficacy, and safety of radioembolization with yttrium-90 (Y90) for unresectable standard-chemorefractory intrahepatic cholangiocarcinoma (ICC). Patients with unresectable standard-chemorefractory ICC treated with Y90 were studied. Survival was calculated from the date of first Y90 procedure. Tumor response was assessed with the Response Evaluation Criteria in Solid Tumors criteria on follow-up computed tomography or magnetic resonance imaging scans. National Cancer Institute Common Terminology Criteria (NCI CTCAE), version 3, were used for complications. Statistical analysis was performed by the Kaplan-Meier estimator by the log rank test. Nineteen patients underwent a total of 24 resin-based Y90 treatments. Median survival from the time of diagnosis and first Y90 procedure was 752 {+-} 193 [95 % confidence interval (CI) 374-1130] and 345 {+-} 128 (95 % CI 95-595) days, respectively. Median survival with Eastern Cooperative Oncology Group (ECOG) performance status 1 (n = 15) and ECOG performance status 2 (n = 4) was 450 {+-} 190 (95 % CI 78-822) and 345 {+-} 227 (95 % CI 0-790) days, respectively (p = .214). Patients with extrahepatic metastasis (n = 11) had a median survival of 404 {+-} 309 (95 % CI 0-1010) days versus 345 {+-} 117 (95 % CI 115-575) days for patients without metastasis (n = 8) (p = .491). No mortality was reported within 30 days from first Y90 radioembolization. One patient developed grade 3 thrombocytopenia as assessed by NCI CTCAE. Fatigue and transient abdominal pain were observed in 4 (21 %) and 6 (32 %) patients, respectively. Y90 radioembolization is effective for unresectable standard-chemorefractory ICC.

  7. Gastric injury from {sup 90}Y to left hepatic lobe tumors adjacent to the stomach: fact or fiction?

    Energy Technology Data Exchange (ETDEWEB)

    Gates, Vanessa L.; Hickey, Ryan; Marshall, Karen; Williams, Melissa; Salzig, Krystina; Lewandowski, Robert J. [Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology, Northwestern Memorial Hospital, Chicago, IL (United States); Salem, Riad [Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology, Northwestern Memorial Hospital, Chicago, IL (United States); Northwestern University, Department of Medicine, Division of Hematology and Oncology, Robert H. Lurie Comprehensive Cancer Center, Chicago, IL (United States)

    2015-12-15

    Radioembolization with {sup 90}Y microspheres is a locoregional radiation therapy for unresectable hepatic neoplasm. Non-target delivery of {sup 90}Y microspheres resulting in gastrointestinal (GI) symptoms is a recognized complication; there is minimal knowledge regarding the radiation effect to the gastric wall from left hepatic lobe {sup 90}Y treatments. Our aim was to study the incidence of GI complications when the target tissue (hepatic parenchyma ± tumor) is in close proximity to the gastric wall. We hypothesized that liver (tumor) to stomach proximity does not correlate with increased toxicity. Between November 2011 and September 2013, we studied all patients who underwent left lobe radioembolization with {sup 90}Y glass microspheres. With Institutional Review Board (IRB) approval, we retrospectively reviewed MRI/CT images of these patients, identifying a subset of patients with the left hepatic lobe <1 cm from the gastric wall. Patients were seen in clinic 1 month posttreatment and subsequently at 3-month intervals. Short- and long-term gastric adverse events were tabulated. Ninety-seven patients successfully underwent left hepatic lobe {sup 90}Y microsphere radioembolization in which the average distance from the liver to the stomach wall was 1.0 ± 2.8 mm. The average dose for patients who received radioembolization to the left hepatic lobe was 109 ± 57 Gy. Fifty patients had tumor within 1 cm of the gastric wall. The average dose for patients who received radioembolization to the left hepatic lobe with tumor within 1 cm of the gastric wall was 121 ± 41 Gy. There were no reportable or recordable medical events. Of the patients, 34 % reported abdominal pain that was grade 1-2; 65 % of the patients reported no abdominal pain. None of the 97 patients developed a clinically evident GI ulcer. Patients with left lobe tumors adjacent to or abutting the stomach do not exhibit acute or chronic radiation effects following radioembolization with glass

  8. Yttrium-86-labelled human serum albumin microspheres: relation of surface structure with in vivo stability

    International Nuclear Information System (INIS)

    Schiller, Eik; Bergmann, Ralf; Pietzsch, Jens; Noll, Bernhard; Sterger, Antje; Johannsen, Bernd; Wunderlich, Gerd; Pietzsch, Hans-Juergen

    2008-01-01

    Introduction: Radiolabelled particles are an attractive tool in the therapy of malignancies of the liver. We consider particles manufactured from denatured human serum albumin (HSA) as useful carriers of therapeutic radionuclides. Covalent attachment of suitable chelators onto the surface of the spheres promises an easy access to radiolabelled HSA microspheres. Methods: We synthesized 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (DOTA) bearing smooth, medium-rough and rough surfaced HSA microspheres (mean diameter: 25 μm). In vitro stability of 86 Y-labelled particles was determined after incubation in human plasma and in a DTPA challenge experiment. In vivo stability of 86 Y DOTA-HSA microspheres was determined after single intravenous application in rats. Subsequently, the particles were completely trapped in the lung microvasculature. Thus, the lung serves in our experiments as target organ. Results: DOTA-HSA microspheres were 86 Y labelled in reproducible high yields (>95%). No differences between smooth and rough surfaced spheres were found for both DOTA coupling and 86 Y labelling. Labelled microspheres showed high in vitro stability in human plasma and in DTPA solution with only 8±1% and 2±0% loss of radioactivity from the surface, respectively, 48 h postinjection (pi). The three batches (smooth, medium-rough and rough surfaced microspheres) differed considerably in their radioactivity recovery in the lungs of rats 48 h pi. Smooth particles showed the highest in vivo stability of the radiolabel on the surface of the spheres, presumably because of slower proteolytic degradation. Conclusion: We found that for the preparation of HSA-derived microspheres for radiotherapeutic application, smooth surfaced spheres are superior to rough spheres due to their higher in vivo stability of the radionuclide fixation

  9. Study of the spheroidization process of glass particles for selective internal radiotherapy

    International Nuclear Information System (INIS)

    Barros Filho, Eraldo Cordeiro

    2012-01-01

    The selective internal radiotherapy is an alternative method to treat hepatocellular carcinoma. Glass microspheres containing radionuclides are introduced in the liver through the hepatic artery, and they are housed preferentially in the region where the cancer cells are located. The microspheres are trapped in the arterioles which feed the tumors, and the β - particles annihilate the cancer cells. When these particles simultaneously emit γ rays, they can also be used to provide images of the tumor. The glass particles must be spherical to avoid unnecessary bleeding, and the particle size must be restricted to a range which is appropriated to trap them and avoid the migration to other parts of the body. Furthermore, they must have a good chemical durability and be nontoxic. The particle size distribution of microspheres is not easily predicted based on the original irregular particles since the variation of the aspect ratio and the presence of agglomerates can influence the final result. In the present work, the spheroidization process to obtain microspheres for radiotherapy treatment was studied. The glass microspheres were characterized by X-rays diffraction, Energy Dispersive X-rays Fluorescence Spectroscopy, Differential Scanning Calorimetry, Specific Superficial Area and cytotoxicity test. The dissolution rate in distilled water at 90 degree C (DR∼10 -8 g.cm - 2.min -1 ), density (2.79g.cm -3 ), viscosity, and size particle distribution were determined. The surface morphological aspect was evaluated by Scanning Electron Microscopy before and after the chemical durability tests in SBF and after the neutron irradiation. It is proposed that the produced material should be sieved to select the most suitable microspheres

  10. Use of yttrium-90 hydroxyapatite radiosynovectomy as a primary modality of treatment in diffuse pigmented villonodular synovitis of the knee joint: A first case report

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppusamy; Rajan, David; Krishnan, Boopathi; Gounder, Thirumalaisamy Subbaih; Chakraborty, Sudipta; Kalarickal, Radhakrishnan; Mohanan, Vyshakh; Shinto, Ajit Sugunan

    2015-01-01

    Pigmented villonodular synovitis (PVNS) is a rare, relatively benign, intra-articular lesion characterized by a slowly progressive proliferation of synovial tissue. Knee is the most frequently involved joint. Localized and diffuse forms of synovial involvement were reported. In extensive diffuse cases, total synovectomy is needed, almost impossible to achieve. Hence, other treatment modalities such as intra-articular injection of yttrium-90 have been tried and shown to be effective in reducing the rate of local recurrence with “acceptable” joint damage. Radiosynovectomy is based on the irradiation of the joint synovium by the intra-articular administration of various β-emitting radiopharmaceuticals. We describe the first case report of use of yttrium-90 hydroxyapatite particulates in a 33-year-old male who presented with diffuse PVNS of knee joint as a primary modality of treatment

  11. Microsphere zeolite materials derived from coal fly ash cenospheres as precursors to mineral-like aluminosilicate hosts for 135,137Cs and 90Sr

    International Nuclear Information System (INIS)

    Vereshchagina, Tatiana A.; Vereshchagin, Sergei N.; Shishkina, Nina N.; Vasilieva, Nataly G.; Solovyov, Leonid A.; Anshits, Alexander G.

    2013-01-01

    Hollow microsphere zeolite materials with a bilayered zeolite/glass crystalline shell bearing NaP1 zeolite were synthesized by the hydrothermal treatment of coal fly ash cenospheres (Si/Al = 2.7) in an alkaline medium. Cs + and/or Sr 2+ forms of zeolitized cenospheres with the different Cs + and/or Sr 2+ loading were prepared by the ion exchange from nitrate solutions. The resulted (Cs,Na)P1, (Sr,Na)P1 and (Cs,Sr,Na)P1 bearing microsphere zeolites were converted to glass ceramics by heating at 900–1000 °C. The differential scanning calorimetry and quantitative phase analysis were used to monitor the solid-phase transformation of the initial and ion exchanged zeolite materials. It was established that the final solidified forms of Cs + and/or Sr 2+ are glass–crystalline ceramic materials based on pollucite–nepheline, Sr-feldspar–nepheline and Sr-feldspar–pollucite composites including ∼60 wt.% of the major host phases (pollucite, Sr-feldspar) and 10–20 wt.% of glass. The 137 Cs leaching rate of 4.1 × 10 −7 g cm −2 day −1 was determined for the pollucite glass–ceramic according to Russian State Standard (GOST) No. 52126 P-2003 (7 day, 25 °C, distilled water)

  12. Long-term product consistency test of simulated 90-19/Nd HLW glass

    International Nuclear Information System (INIS)

    Gan, X.Y.; Zhang, Z.T.; Yuan, W.Y.; Wang, L.; Bai, Y.; Ma, H.

    2011-01-01

    Chemical durability of 90-19/Nd glass, a simulated high-level waste (HLW) glass in contact with the groundwater was investigated with a long-term product consistency test (PCT). Generally, it is difficult to observe the long term property of HLW glass due to the slow corrosion rate in a mild condition. In order to overcome this problem, increased contacting surface (S/V = 6000 m -1 ) and elevated temperature (150 o C) were employed to accelerate the glass corrosion evolution. The micro-morphological characteristics of the glass surface and the secondary minerals formed after the glass alteration were analyzed by SEM-EDS and XRD, and concentrations of elements in the leaching solution were determined by ICP-AES. In our experiments, two types of minerals, which have great impact on glass dissolution, were found to form on 90-19/Nd HLW glass surface when it was subjected to a long-term leaching in the groundwater. One is Mg-Fe-rich phyllosilicates with honeycomb structure; the other is aluminosilicates (zeolites). Mg and Fe in the leaching solution participated in the formation of phyllosilicates. The main components of phyllosilicates in alteration products of 90-19/Nd HLW glass are nontronite (Na 0.3 Fe 2 Si 4 O 10 (OH) 2 .4H 2 O) and montmorillonite (Ca 0.2 (Al,Mg) 2 Si 4 O 10 (OH) 2 .4H 2 O), and those of aluminosilicates are mordenite ((Na 2 ,K 2 ,Ca)Al 2 Si 10 O 24 .7H 2 O)) and clinoptilolite ((Na,K,Ca) 5 Al 6 Si 30 O 72 .18H 2 O). Minerals like Ca(Mg)SO 4 and CaCO 3 with low solubility limits are prone to form precipitant on the glass surface. Appearance of the phyllosilicates and aluminosilicates result in the dissolution rate of 90-19/Nd HLW glass resumed, which is increased by several times over the stable rate. As further dissolution of the glass, both B and Na in the glass were found to leach out in borax form.

  13. Crystallization in Y-Si-Al-O-N glasses

    Energy Technology Data Exchange (ETDEWEB)

    Leng-Ward, G; Lewis, M H

    1985-05-01

    The development of crystallization in oxynitride glasses has been characterized using transmission electron microscopy and scanning electron microscopy, X-ray (energy-dispersive) microanalysis, and powder X-ray diffraction techniques. A series of glasses was prepared while maintaining the ratio of yttrium-to-silicon-to-aluminium, but replacing oxygen with nitrogen up to the nitrogen solubility limit. On annealing at 1250 C, the oxide glass fully crystallized into yttrium disilicate (Y2Si2O7). Al2O3 and mullite (Al6Si2O13) while, with increasing nitrogen content, the disilicate phase was progressively replaced by yttrium aluminium garnet (Y3Al5O12) and nitrogen was mainly incorporated into Si2N2O. Annealing of the nitrogen glasses at 1100 C produced partial crystallization involving an intermediate phase related to nitrogen-wollastonite. Phase separation in an as-quenched SiO2-rich Y-Si-Al-O composition glass is illustrated. 9 references.

  14. Therapy with 90Y microspheres: radiation protection in new medical therapies

    International Nuclear Information System (INIS)

    Rojo, Ana; Puerta, Nancy

    2013-01-01

    Primary liver cancer is one of the most frequent in the world and with a low cure rate. Radioembolization using 90y spheres is a promising treatment of this pathology and involves the percutaneous vascular application of radioisotope-labeled the order of Micron size particles. The advantages of this technique include the permit administered high doses of radiation to small volumes with low relative toxicity, offer the possibility of treating all the liver including microscopic tumors, and finally, the feasibility of combined with other therapies. Radiation protection in new medical therapies requires justification and optimization, as requirements for their implementation. The application of the principle of optimization in the context of the protection of the patient must be the minimum that it can be reasonably reached compatible with the required doses of treatment dose to healthy tissue. With 90 Y microspheres therapy this optimization applies to the activity of 90y which is administered to the patient, and estimation methods are postulated. in this work are analyzed comparatively these methods, described the early physicists, equations and the limitations of each. Finally, it is concluded that the optimal method to be implemented for the evaluation of the activity of 90 Y manage must be based in a voxel dosimetric model specific for each patient, however, the partitional method may be a good alternative if you don't have the tools to apply the method

  15. Biodistribution of Yttrium-90-Labeled Anti-CD45 Antibody in a Nonhuman Primate Model

    International Nuclear Information System (INIS)

    Nemecek, Eneida; Hamlin, Donald K.; Fisher, Darrell R.; Krohn, Kenneth A.; Pagel, John M.; Applebaum, F. R.; Press, Oliver W.; Matthews, Dana C.

    2005-01-01

    Radioimmunotherapy may improve the outcome of hematopoietic cell transplantation for hematologic malignancies by delivering targeted radiation to hematopoietic organs while relatively sparing nontarget organs. We evaluated the organ localization of yttrium-90-labeled anti-CD45 (90Y-anti-CD45) antibody in macaques, a model that had previously predicted iodine-131-labeled anti-CD-45 (131I-anti-CD45) antibody biodistribution in humans. Experimental Design: Twelve Macaca nemestrina primates received anti-CD45 antibody labeled with 1 to 2 mCi of 90Y followed by serial blood sampling and marrow and lymph node biopsies, and necropsy. The content of 90Y per gram of tissue was determined by liquid scintillation spectrometry. Time-activity curves were constructed using average isotope concentrations in each tissue at measured time points to yield the fractional residence time and estimate radiation absorbed doses for each organ per unit of administered activity. The biodistribution of 90Y-anti-CD45 antibody was then compared with that previously obtained with 131I-anti-CD45 antibody in macaques. Results: The spleen received 2,120, marrow 1,060, and lymph nodes 315 cGy/mCi of 90Y injected. The liver and lungs were the nontarget organs receiving the highest radiation absorbed doses (440 and 285 cGy/mCi, respectively). Ytrrium-90-labeled anti-CD45 antibody delivered 2.5- and 3.7-fold more radiation to marrow than to liver and lungs, respectively. The ratios previously observed with 131I-antiCD45 antibody were 2.5-and 2.2-fold more radiation to marrow than to liver and lungs, respectively. Conclusions: This study shows that 90Y-anti-CD45 antibody can deliver relatively selective radiation to hematopoietic tissues, with similar ratios of radiation delivered to target versus nontarget organs, as compared with the 131I immunoconjugate in the same animal model

  16. Towards modular bone tissue engineering using Ti-Co-doped phosphate glass microspheres: cytocompatibility and dynamic culture studies.

    Science.gov (United States)

    Peticone, Carlotta; De Silva Thompson, David; Owens, Gareth J; Kim, Hae-Won; Micheletti, Martina; Knowles, Jonathan C; Wall, Ivan

    2017-09-01

    The production of large quantities of functional vascularized bone tissue ex vivo still represent an unmet clinical challenge. Microcarriers offer a potential solution to scalable manufacture of bone tissue due to their high surface area-to-volume ratio and the capacity to be assembled using a modular approach. Microcarriers made of phosphate bioactive glass doped with titanium dioxide have been previously shown to enhance proliferation of osteoblast progenitors and maturation towards functional osteoblasts. Furthemore, doping with cobalt appears to mimic hypoxic conditions that have a key role in promoting angiogenesis. This characteristic could be exploited to meet the clinical requirement of producing vascularized units of bone tissue. In the current study, the human osteosarcoma cell line MG-63 was cultured on phosphate glass microspheres doped with 5% mol titanium dioxide and different concentrations of cobalt oxide (0%, 2% and 5% mol), under static and dynamic conditions (150 and 300 rpm on an orbital shaker). Cell proliferation and the formation of aggregates of cells and microspheres were observed over a period of two weeks in all glass compositions, thus confirming the biocompatibility of the substrate and the suitability of this system for the formation of compact micro-units of tissue. At the concentrations tested, cobalt was not found to be cytotoxic and did not alter cell metabolism. On the other hand, the dynamic environment played a key role, with moderate agitation having a positive effect on cell proliferation while higher agitation resulting in impaired cell growth. Finally, in static culture assays, the capacity of cobalt doping to induce vascular endothelial growth factor (VEGF) upregulation by osteoblastic cells was observed, but was not found to increase linearly with cobalt oxide content. In conclusion, Ti-Co phosphate glasses were found to support osteoblastic cell growth and aggregate formation that is a necessary precursor to tissue

  17. Phase composition of yttrium-doped zirconia ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Hennig, Christoph; Scheinost, Andreas C. [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Molecular Structures; Weiss, Stephan [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Surface Processes; Ikeda-Ohno, Atsushi [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Chemistry of the F-Elements; Gumeniuk, R. [Technische Univ. Bergakademie Freiberg (Germany). Inst. fuer Experimentelle Physik

    2017-06-01

    Ceramic material might be an alternative to borosilicate glass for the immobilization of nuclear waste. The crystallinity of ceramic material increases the corrosion resistance over several magnitudes in relation to amorphous glasses. The stability of such ceramics depend on several parameters, among them the crystal phase composition. A reliable quantitative phase analysis is necessary to correlate the macroscopic material properties with structure parameters. We performed a feasibility study based on yttrium-doped zirconia ceramics as analogue for trivalent actinides to ascertain that the nanosized crystal phases in zirconia ceramics can be reliably determined.

  18. Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Hagspiel, Klaus D., E-mail: kdh2n@virginia.edu [University of Virginia Health System, Department of Radiology and Medical Imaging (United States); Nambiar, Ashwin, E-mail: uvashwin@gmail.com [SUNY Downstate Medical Center, Department of Radiology (United States); Hagspiel, Lauren M., E-mail: lmh4gg@virginia.edu [University of Virginia, College of Arts and Sciences (United States); Ahmad, Ehab Ali, E-mail: ehabradiodiagnosis@yahoo.com [Minia University, Department of Radiology (Egypt); Bozlar, Ugur, E-mail: ubozlar@yahoo.com [Gulhane Military Medical Academy, Department of Radiology (Turkey)

    2013-06-15

    Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Five arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.

  19. Adsorption of 90Sr and 90Y by bottom-set beds in the Atlantic ocean

    International Nuclear Information System (INIS)

    Gromov, V.V.; Shakhova, N.F.; Emel'yanov, E.M.

    1978-01-01

    The behaviour of 90 Sr and 90 Y has been studied in an adsorption system of sea water-bottom-set beds of the Atlantic ocean (red clay; pelitic silt). It has been shown that strontium is present in the sea water in one form, viz, Sr 2+ . Adsorption of 90 Sr with bottom-set beds follows the ion-exchange mechanism. Yttrium is present in the sea water at least three forms (two absorbable and one non-absorbable). Yttrium-90 adsorption is an irreversible process and only about 10% 90 Y is desorbed by the sea water from red clay and silt

  20. Radioembolization of hepatocarcinoma with 90Y glass microspheres: development of an individualized treatment planning strategy based on dosimetry and radiobiology

    International Nuclear Information System (INIS)

    Chiesa, C.; Maccauro, M.; Aliberti, G.; Padovano, B.; Seregni, E.; Crippa, F.; Mira, M.; Negri, A.; Spreafico, C.; Morosi, C.; Civelli, E.; Lanocita, R.; Marchiano, A.; Romito, R.; Sposito, C.; Bhoori, S.; Facciorusso, A.; Mazzaferro, V.; Camerini, T.; Carrara, M.; Pellizzari, S.; Migliorisi, M.; De Nile, M.C.

    2015-01-01

    The aim of this study was to optimize the dosimetric approach and to review the absorbed doses delivered, taking into account radiobiology, in order to identify the optimal methodology for an individualized treatment planning strategy based on 99m Tc-macroaggregated albumin (MAA) single photon emission computed tomography (SPECT) images. We performed retrospective dosimetry of the standard TheraSphere registered treatment on 52 intermediate (n = 17) and advanced (i.e. portal vein thrombosis, n = 35) hepatocarcinoma patients with tumour burden < 50 % and without obstruction of the main portal vein trunk. Response was monitored with the densitometric radiological criterion (European Association for the Study of the Liver) and treatment-related liver decompensation was defined ad hoc with a time cut-off of 6 months. Adverse events clearly attributable to disease progression or other causes were not attributed to treatment. Voxel dosimetry was performed with the local deposition method on 99m Tc-MAA SPECT images. The reconstruction protocol was optimized. Concordance of 99m Tc-MAA and 90 Y bremsstrahlung microsphere biodistributions was studied in 35 sequential patients. Two segmentation methods were used, based on SPECT alone (home-made code) or on coregistered SPECT/CT images (IMALYTICS trademark by Philips). STRATOS trademark absorbed dose calculation was validated for 90 Y with a single time point. Radiobiology was used introducing other dosimetric variables besides the mean absorbed dose D: equivalent uniform dose (EUD), biologically effective dose averaged over voxel values (BED ave ) and equivalent uniform biologically effective dose (EUBED). Two sets of radiobiological parameters, the first derived from microsphere irradiation and the second from external beam radiotherapy (EBRT), were used. A total of 16 possible methodologies were compared. Tumour control probability (TCP) and normal tissue complication probability (NTCP) were derived. The area under the

  1. 3D inpatient dose reconstruction from the PET-CT imaging of 90Y microspheres for metastatic cancer to the liver: feasibility study.

    Science.gov (United States)

    Fourkal, E; Veltchev, I; Lin, M; Koren, S; Meyer, J; Doss, M; Yu, J Q

    2013-08-01

    The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres. The Fluka Monte Carlo code was used to calculate the voxel dose kernel for 90Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures. The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58-3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71-311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25-155 Gy). Mean minimum dose to 90% of target (D90) was 53 Gy (range: 13-125 Gy). A

  2. Neutron transmission measurements on hydrogen filled microspheres

    International Nuclear Information System (INIS)

    Dyrnjaja, Eva; Hummel, Stefan; Keding, Marcus; Smolle, Marie-Theres; Gerger, Joachim; Zawisky, Michael

    2014-01-01

    Hollow microspheres are promising candidates for future hydrogen storage technologies. Although the physical process for hydrogen diffusion through glass is well understood, measurements of static quantities (e.q. hydrogen pressure inside the spheres) as well as dynamic properties (e.g. diffusion rate of hydrogen through glass) are still difficult to handle due to the small size of the spheres (d≈15μm). For diffusion rate measurements, the long-term stability of the experiment is also mandatory due to the relatively slow diffusion rate. In this work, we present an accurate and long-term stable measurement technique for static and dynamic properties, using neutron radiography. Furthermore, possible applications for hydrogen filled microspheres within the scope of radiation issues are discussed

  3. Antibody-guided three-step therapy for high grade glioma with yttrium-90 biotin

    International Nuclear Information System (INIS)

    Paganelli, G.; Grana, C.; Chinol, M.; Cremonesi, M.; De Cicco, C.; Zoboli, S.; De Braud, F.; Robertson, C.; Zurrida, S.; Veronesi, U.; Casadio, C.; Siccardi, A.G.

    1999-01-01

    While the incidence of brain tumours seems to be increasing, median survival in patients with glioblastoma remains less than 1 year, despite improved diagnostic imaging and neurosurgical techniques, and innovations in treatment. We have developed an avidin-biotin pre-targeting approach for delivering therapeutic radionuclides to gliomas, using anti-tenascin monoclonal antibodies, which seems potentially effective for treating these tumours. We treated 48 eligible patients with histologically confirmed grade III or IV glioma and documented residual disease or recurrence after conventional treatment. Three-step radionuclide therapy was performed by intravenous administration of 35 mg/m 2 of biotinylated anti-tenascin monoclonal antibody (1st step), followed 36 h later by 30 mg of avidin and 50 mg of streptavidin (2nd step), and 18-24 h later by 1-2 mg of yttrium-90-labelled biotin (3rd step). 90 Y doses of 2.22-2.96 GBq/m 2 were administered; maximum tolerated dose (MTD) was determined at 2.96 GBq/m 2 . Tumour mass reduction (>25%-100%), documented by computed tomography or magnetic resonance imaging, occurred in 12/48 patients (25%), with 8/48 having a duration of response of at least 12 months. At present, 12 patients are still in remission, comprising four with a complete response, two with a parital response, two with a minor response and four with stable disease. Median survival from 90 Y treatment is 11 months for grade IV glioblastoma and 19 months for grade III anaplastic gliomas. Avidin-biotin based three-step radionuclide therapy is well tolerated at the dose of 2.2 GBq/m 2 , allowing the injection of 90 Y-biotin without bone marrow transplantation. This new approach interferes with the progression of high-grade glioma and may produce tumour regression in patients no longer responsive to other therapies. (orig.)

  4. Yttrium and lanthanum recovery from low cerium carbonate, yttrium carbonate and yttrium concentrate

    International Nuclear Information System (INIS)

    Vasconcelos, Mari Estela de

    2006-01-01

    In this work, separation, enrichment and purification of lanthanum and yttrium were performed using as raw material a commercial low cerium rare earth concentrate named LCC (low cerium carbonate), an yttrium concentrate named 'yttrium carbonate', and a third concentrated known as 'yttrium earths oxide. The first two were industrially produced by the late NUCLEMON - NUCLEBRAS de Monazita e Associados Ltda, using Brazilian monazite. The 'yttrium earths oxide' come from a process for preparation of lanthanum during the course of the experimental work for the present thesis. The following techniques were used: fractional precipitation with urea; fractional leaching of the LCC using ammonium carbonate; precipitation of rare earth peroxycarbonates starting from the rare earth complex carbonates. Once prepared the enriched rare earth fractions the same were refined using the ion exchange chromatography with strong cationic resin without the use of retention ion and elution using the ammonium salt of ethylenediaminetetraacetic acid. With the association of the above mentioned techniques were obtained pure oxides of yttrium (>97,7%), lanthanum (99,9%), gadolinium (96,6%) and samarium (99,9%). The process here developed has technical and economic viability for the installation of a large scale unity. (author)

  5. 3D inpatient dose reconstruction from the PET-CT imaging of 90Y microspheres for metastatic cancer to the liver: Feasibility study

    International Nuclear Information System (INIS)

    Fourkal, E.; Veltchev, I.; Lin, M.; Meyer, J.; Koren, S.; Doss, M.; Yu, J. Q.

    2013-01-01

    Purpose: The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres.Methods: The Fluka Monte Carlo code was used to calculate the voxel dose kernel for 90 Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures.Results: The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58–3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71–311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25–155 Gy). Mean minimum dose to 90% of target (D90

  6. Radioembolization of hepatocarcinoma with {sup 90}Y glass microspheres: development of an individualized treatment planning strategy based on dosimetry and radiobiology

    Energy Technology Data Exchange (ETDEWEB)

    Chiesa, C.; Maccauro, M.; Aliberti, G.; Padovano, B.; Seregni, E.; Crippa, F. [Foundation IRCCS Istituto Nazionale Tumori, Nuclear Medicine Division, Milan (Italy); Mira, M.; Negri, A. [University of Milan, Postgraduate Health Physics School, Milan (Italy); Spreafico, C.; Morosi, C.; Civelli, E.; Lanocita, R.; Marchiano, A. [Foundation IRCCS Istituto Nazionale Tumori, Radiology 2, Milan (Italy); Romito, R.; Sposito, C.; Bhoori, S.; Facciorusso, A.; Mazzaferro, V. [Foundation IRCCS Istituto Nazionale Tumori, Surgery 1, Milan (Italy); Camerini, T. [Foundation IRCCS Istituto Nazionale Tumori, Scientific Direction, Milan (Italy); Carrara, M. [Foundation IRCCS Istituto Nazionale Tumori, Health Physics, Milan (Italy); Pellizzari, S. [University La Sapienza, Engineering Faculty, Rome (Italy); Migliorisi, M. [Foundation IRCCS Istituto Nazionale Tumori, Nuclear Medicine Division, Milan (Italy); Foundation IRCCS Istituto Nazionale Tumori, Clinical Engineering, Milan (Italy); De Nile, M.C. [University of Pavia, Physics Faculty, Pavia, Lombardy (Italy)

    2015-10-15

    The aim of this study was to optimize the dosimetric approach and to review the absorbed doses delivered, taking into account radiobiology, in order to identify the optimal methodology for an individualized treatment planning strategy based on {sup 99m}Tc-macroaggregated albumin (MAA) single photon emission computed tomography (SPECT) images. We performed retrospective dosimetry of the standard TheraSphere registered treatment on 52 intermediate (n = 17) and advanced (i.e. portal vein thrombosis, n = 35) hepatocarcinoma patients with tumour burden < 50 % and without obstruction of the main portal vein trunk. Response was monitored with the densitometric radiological criterion (European Association for the Study of the Liver) and treatment-related liver decompensation was defined ad hoc with a time cut-off of 6 months. Adverse events clearly attributable to disease progression or other causes were not attributed to treatment. Voxel dosimetry was performed with the local deposition method on {sup 99m}Tc-MAA SPECT images. The reconstruction protocol was optimized. Concordance of {sup 99m}Tc-MAA and {sup 90}Y bremsstrahlung microsphere biodistributions was studied in 35 sequential patients. Two segmentation methods were used, based on SPECT alone (home-made code) or on coregistered SPECT/CT images (IMALYTICS trademark by Philips). STRATOS trademark absorbed dose calculation was validated for {sup 90}Y with a single time point. Radiobiology was used introducing other dosimetric variables besides the mean absorbed dose D: equivalent uniform dose (EUD), biologically effective dose averaged over voxel values (BED{sub ave}) and equivalent uniform biologically effective dose (EUBED). Two sets of radiobiological parameters, the first derived from microsphere irradiation and the second from external beam radiotherapy (EBRT), were used. A total of 16 possible methodologies were compared. Tumour control probability (TCP) and normal tissue complication probability (NTCP) were

  7. Attempts at treating rheumatoid arthritis with radioactive yttrium

    International Nuclear Information System (INIS)

    Scott, J.T.

    1979-01-01

    Two years' observations on 33 knee joints in 33 patients with rheumatoid arthritis did not prove a therapeutic effect of Y 90 , which was tested in a randomized study against non-radioactive yttrium. It was noticable that 9 knee joints of the isotope group but only one of the control group became unstable. Independent of the yttrium treatment, significant improvement was noticed in patients where fibrin clots had been washed out of the joints in the course of arthroscopies. (orig.) [de

  8. Lung Shunt Fraction prior to Yttrium-90 Radioembolization Predicts Survival in Patients with Neuroendocrine Liver Metastases: Single-Center Prospective Analysis

    International Nuclear Information System (INIS)

    Ludwig, Johannes M.; Ambinder, Emily McIntosh; Ghodadra, Anish; Xing, Minzhi; Prajapati, Hasmukh J.; Kim, Hyun S.

    2016-01-01

    ObjectiveTo investigate survival outcomes following radioembolization with Yttrium-90 (Y90) for neuroendocrine tumor liver metastases (NETLMs). This study was designed to assess the efficacy of Y90 radioembolization and to evaluate lung shunt fraction (LSF) as a predictor for survival.MethodsA single-center, prospective study of 44 consecutive patients (median age: 58.5 years, 29.5 % male) diagnosed with pancreatic (52.3 %) or carcinoid (47.7 %) NETLMs from 2006 to 2012 who underwent Y90 radioembolization was performed. Patients’ baseline characteristics, including LSF and median overall survival (OS) from first Y90 radioembolization, were recorded and compared between patients with high (≥10 %) and low ( 1.2 mg (p = 0.016), and lack of pretreatment with octreotide (p = 0.01) as independent prognostic factors for poorer survival. Tumor type and total radiation dose did not predict survival.ConclusionsLSF ≥10 %, elevated bilirubin levels, and lack of pretreatment with octreotide were found to be independent prognostic factors for poorer survival in patients with NETLMs.

  9. Attempted treatment of meningeosis leucaemica by intrathecal application of 90-silicate and 90Y-citrate colloid in a case of chronic myleoic leukaemia; Behandlungsversuch einer Meningeosis leucaemica durch intrathekale Applikation von {sup 90}Y-Silikat- und {sup 90}Y-Zitrat-Kolloid bei chronisch-myleoischer Leukaemie

    Energy Technology Data Exchange (ETDEWEB)

    Kittner, C.; Schuemichen, C. [Rostock Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Steiner, B.; Kahl, C.; Wolff, D.; Freund, M. [Rostock Univ. (Germany). Klinik fuer Innere Medizin, Abt. fuer Haematologie; Putzar, H.; Roesler, K.; Hauenstein, K.H. [Rostock Univ. (Germany). Inst. fuer Diagnostische und Interventionalle Radiologie

    2003-12-01

    A 41-year-old man with chronic myeoloic leukaemia was treated for Meningeosis leucaemica by intrathecal application of yttrium-90-citrate colloide as palliative therapy. (orig.) [German] Wir berichten ueber einen 41-jaehrigen Mann mit chronisch-myeloischer Leukaemie bei dem eine Meningeosis leucaemica durch eine intrathekale Applikation von Yttrium-90-Zitrat-Kolloid palliativ therapiert wurde. (orig.)

  10. Treatment of unresectable hepatocellular carcinoma with use of 90Y microspheres (TheraSphere): safety, tumor response, and survival.

    Science.gov (United States)

    Salem, Riad; Lewandowski, Robert J; Atassi, Bassel; Gordon, Stuart C; Gates, Vanessa L; Barakat, Omar; Sergie, Ziad; Wong, Ching-Yee O; Thurston, Kenneth G

    2005-12-01

    To present safety and efficacy results obtained in treatment of a cohort of patients with unresectable hepatocellular carcinoma (HCC) with use of 90Y microspheres (TheraSphere). Forty-three consecutive patients with HCC were treated with 90Y microspheres over a 4-year period. Patients were treated by liver segment or lobe on one or more occasions based on tumor distribution, liver function, and vascular flow dynamics. Patients were followed for adverse events, objective tumor response, and survival. Patients were stratified into three risk groups according to method of treatment and risk stratification (group 0, segmental; group 1, lobar low-risk; group 2, lobar high-risk) and Okuda and Child-Pugh scoring systems. Based on follow-up data from 43 treated patients, 20 patients (47%) had an objective tumor response based on percent reduction in tumor size and 34 patients (79%) had a tumor response when percent reduction and/or tumor necrosis were used as a composite measure of tumor response. There was no statistical difference among the three risk groups with respect to tumor response. Survival times from date of diagnosis were different among the risk groups (P TheraSpheres) provides a safe and effective method of treatment for a broad spectrum of patients presenting with unresectable HCC. Further investigation is warranted.

  11. Silicon microspheres for near-IR communication applications

    International Nuclear Information System (INIS)

    Serpengüzel, Ali; Demir, Abdullah

    2008-01-01

    We have performed transverse electric and transverse magnetic polarized elastic light scattering calculations at 90° and 0° in the o-band at 1.3 µm for a 15 µm radius silicon microsphere with a refractive index of 3.5. The quality factors are on the order of 10 7 and the mode/channel spacing is 7 nm, which correlate well with the refractive index and the optical size of the microsphere. The 90° elastic light scattering can be used to monitor a dropped channel (drop port), whereas the 0° elastic scattering can be used to monitor the transmission channel (through port). The optical resonances of the silicon microspheres provide the necessary narrow linewidths that are needed for high-resolution optical communication applications. Potential telecommunication applications include filters, modulators, switches, wavelength converters, detectors, amplifiers and light sources. Silicon microspheres show promise as potential building blocks for silicon-based electrophotonic integration

  12. Evaluation of the parameters of SPECT images for yttrium-90 in radiosinoviorthesis; Avaliação dos parâmetros de aquisição de imagens SPECT para ítrio-90 em radiosinoviortese

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, B.C. de; Sáa, L.V. de, E-mail: bruce.de.toledo@gmail.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Física Médica; Ramos, S.M.; Coelho, F.A.; Thomas, S.; Souza, S.A. de; Pinheiro, M.A. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Hospital Universitário Clementino Fraga Filho

    2017-07-01

    Introduction: the evaluation of the distribution of radioactive material in the articulation by SPECT images after radiosinoviorthesis (RSO) can guarantee the efficacy of this therapy. However, Bremsstrahlung image quality has major limitations, necessitating studies on SPECT image acquisition parameters and yttrium-90 image reconstruction methods. Methods: SPECT images were obtained from an acrylic simulator containing four cylindrical inserts to simulate capturing lesions. The images were obtained with collimators of high, medium and low (HEGP, MEGP and LEHR) energy; 130 keV power window, 70% width and 64 x 64 matrix. The reconstruction methods used were: FBP and OSEM with different filters. Results: 45 results found. The images obtained with the MEGP and HEGP collimators presented better results than those obtained with the LEHR collimator. The OSEM reconstructions were superior when the MEGP and HEGP collimators were used. Conclusions: The acquisition of yttrium-90 SPECT images with MEGP collimators showed higher sensitivity, whereas those obtained with HEPG collimators presented lower noise. The image reconstruction methods have relevant importance in the image quality, showing a significant difference between the FBP and OSEM reconstructions and between the filters used.

  13. Pregnancies in women with hyperprolactinaemia: clinical course and obstetric complications of 41 pregnancies in 27 women. [Yttrium 90

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, W.F.; Doyle, F.H.; Mashiter, K.; Banks, L.M.; Gordon, H.; Joplin, G.F.

    1979-09-01

    Observations are reported on 41 pregnancies in 27 patients who initially had infertility and raised serum prolactin concentrations. Associated symptoms were secondary amenorrhoea and galactorrhoea. All patients were at risk of pituitary expansion during pregnancy, especially these 19 (70 per cent) with radiological evidence of pituitary tumors. Fifteen patients had 21 pregnancies after pituitary implantation with 90 yttrium; 14 patients had 20 pegnancies without prior pituitary implantation or any other attempt to prevent tumor expansion. The induction and Cesarean section rates were about 30 per cent in 32 term pregnancies in 25 patients. Details of how pregnancy was achieved and the associated obstetric problems are given.

  14. 3D inpatient dose reconstruction from the PET-CT imaging of {sup 90}Y microspheres for metastatic cancer to the liver: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Fourkal, E.; Veltchev, I.; Lin, M.; Meyer, J. [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States); Koren, S. [Department of Radiation Oncology, Beth Israel Comprehensive Cancer Center, New York, New York 10011 (United States); Doss, M.; Yu, J. Q. [Department of Diagnostic Imaging, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2013-08-15

    Purpose: The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres.Methods: The Fluka Monte Carlo code was used to calculate the voxel dose kernel for {sup 90}Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures.Results: The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58–3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71–311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25–155 Gy). Mean minimum dose to 90% of target

  15. Preparation of microspheres for slow release drug by radiation-induced suspension polymerization and their properties

    International Nuclear Information System (INIS)

    Yoshida, Masaru; Asano, Masaharu; Kaetsu, Isao

    1982-01-01

    The polymer microspheres containing drugs as drug delivery system were made by means of suspension-polymerization by radiation at low temperature by using glass-forming monomers which have stable supercooling properties and large polymerizability at low temperature. The particle distribution depended on the kind of monomer. It was found that the entrapping yield of drug in polymer microspheres increased with increasing viscosity of monomer and that the maximum value on the particle size distribution curve was also shifted to large particle diameter side. In the case of trimethylolpropane trimethacrylate monomer (43 cps), TMPT, the entrapping yield of drug reached 74% and the maximum value in particle size distribution curve appeared in the neighborhood of 105 to 210 mu m ranges. On the other hand, those values in neopentyl glycol dimethacrylate monomer (4 cps) were 12% in former and 44 -- 105 mu m in the latter. The release phenomenon of drugs from polymer microspheres was investigated. for example, the cumulative amount of mitomycin C (water soluble drug) released from TMPT polymer microsphere was about 90% after 30-day dissolution, while in the case of water-insoluble drug such as testosterone the amount of release was about 49% after 40-day dissolution. In all cases, the release rate is constant during the experimental period. Therefore, it was concluded that the release of drugs from polymer microspheres obtained in this study is possible over the long periods. (author)

  16. Study on the leach mechanism of 90-19/U glass form in underground water of disposal site

    International Nuclear Information System (INIS)

    Sheng Jiawei; Luo Shanggeng; Tang Baolong

    1996-01-01

    The leach behavior of 90-19/U glass form in underground water (UW) of disposal site and in the deionized water (DIW) is studied. The total mass losses of glass form and the normalized element mass losses of B, Li and Si in UW are presented and compared to DIW. It is found that the ions in UW affect the leach behavior of 90-19/U glass. At the beginning of the reaction the reaction rate of the glass is smaller in UW than in DIW due to the low glass dissolution affinity in UW which is defined as (1-c/K). The rate determining step of leach reaction of 90-19/U glass in UW during the entire reaction period is the ion-exchange reaction. The apparent activation energy of glass reaction in UW is 51.6 kJ/mol

  17. Collimator and energy window optimization for 90Y bremsstrahlung SPECT imaging: A SIMIND Monte Carlo study

    International Nuclear Information System (INIS)

    Roshan, Hoda Rezaei; Mahmoudian, Babak; Gharepapagh, Esmaeil; Azarm, Ahmadreza; Pirayesh Islamian, Jalil

    2016-01-01

    Treatment efficacy of radioembolization using Yttrium-90 ( 90 Y) microspheres is assessed by the 90 Y bremsstrahlung single photon emission computed tomography (SPECT) imaging following radioembolization. The radioisotopic image has the potential of providing reliable activity map of 90 Y microspheres distribution. One of the main reasons of the poor image quality in 90 Y bremsstrahlung SPECT imaging is the continuous and broad energy spectrum of the related bremsstrahlung photons. Furthermore, collimator geometry plays an impressive role in the spatial resolution, sensitivity and image contrast. Due to the relatively poor quality of the 90 Y bremsstrahlung SPECT images, we intend to optimize the medium-energy (ME) parallel-hole collimator and energy window. The Siemens e.cam gamma camera equipped with a ME collimator and a voxelized phantom was simulated by the SImulating Medical Imaging Nuclear Detectors (SIMIND) program. We used the SIMIND Monte Carlo program to generate the 90 Y bremsstrahlung SPECT projection of the digital Jaszczak phantom. The phantom consist of the six hot spheres ranging from 9.5 to 31.8 mm in diameter, which are used to evaluate the image contrast. In order to assess the effect of the energy window on the image contrast, three energy windows ranging from 60 to 160 KeV, 160 to 400 KeV, and 60 to 400 KeV were set on a 90 Y bremsstrahlung spectrum. As well, the effect of the hole diameter of a ME collimator on the image contrast and bremsstrahlung spectrum were investigated. For the fixed collimator and septa thickness values (3.28 cm and 1.14 mm, respectively), a hole diameter range (2.35–3.3 mm) was chosen based on the appropriate balance between the spatial resolution and sensitivity. The optimal energy window for 90 Y bremsstrahlung SPECT imaging was extended energy window from 60 to 400 KeV. Besides, The optimal value of the hole diameter of ME collimator was obtained 3.3 mm. Geometry of the ME parallel-hole collimator and energy

  18. Treating and Downstaging Hepatocellular Carcinoma in the Caudate Lobe with Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Saad M. [Northwestern University Feinberg School of Medicine, Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology (United States); Kulik, Laura [Northwestern University Feinberg School of Medicine, Department of Medicine, Division of Hepatology (United States); Baker, Talia [Northwestern University Feinberg School of Medicine, Division of Transplant Surgery (United States); Ryu, Robert K. [Northwestern University Feinberg School of Medicine, Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology (United States); Mulcahy, Mary F. [Northwestern University Feinberg School of Medicine, Department of Medicine, Division of Hematology and Oncology, Robert H. Lurie Comprehensive Cancer Center (United States); Abecassis, Michael [Northwestern University Feinberg School of Medicine, Division of Transplant Surgery (United States); Salem, Riad; Lewandowski, Robert J., E-mail: r-lewandowski@northwestern.edu [Northwestern University Feinberg School of Medicine, Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology (United States)

    2012-10-15

    Purpose: This study was designed to determine the technical feasibility, safety, efficacy, and potential to downstage patients to within transplantation criteria when treating patients with hepatocellular carcinoma (HCC) of the caudate lobe using Y90 radioembolization. Methods: During a 4-year period, 8 of 291 patients treated with radioembolization for unresectable HCC had disease involving the caudate lobe. All patients were followed for treatment-related clinical/biochemical toxicities, serum tumor marker response, and treatment response. Imaging response was assessed with the World Health Organization (WHO) and European Association for the Study of the Liver (EASL) classification schemes. Pathologic response was reported as percent necrosis at explantation. Results: Caudate lobe radioembolization was successfully performed in all eight patients. All patients presented with both cirrhosis and portal hypertension. Half were United Network for Organ Sharing (UNOS) stage T3 (n = 4, 50%). Fatigue was reported in half of the patients (n = 4, 50%). One (13%) grade 3/4 bilirubin toxicity was reported. One patient (13%) showed complete tumor response by WHO criteria, and three patients (38%) showed complete response using EASL guidelines. Serum AFP decreased by more than 50% in most patients (n = 6, 75%). Four patients (50%) were UNOS downstaged from T3 to T2, three of who underwent transplantation. One specimen showed histopathologic evidence of 100% complete necrosis, and two specimens demonstrated greater than 50% necrosis. Conclusions: Radioembolization with yttrium-90 appears to be a feasible, safe, and effective treatment option for patients with unresectable caudate lobe HCC. It has the potential to downstage patients to transplantation.

  19. 90Sr-90Y radionuclide generator based on ionex chromatography. Part 1 - project

    International Nuclear Information System (INIS)

    Miler, V.; Budsky, F.; Malek, Z.

    2003-09-01

    This part contains a proposal for the generator column design, materials to be used (chemicals, ionexes) and technological procedures. The proposal was inspired by the 90 Sr- 90 Y generator operated by Zfk Rossendorf. The aim was to develop and launch a generator for the preparation of carrier-free 90 Y in the form of [ 90 Y] chloride solution in dilute hydrochloric acid. The separation of Y from Sr is based on ionex chromatography by sorbing the two radionuclides on a catex. While Sr remains sorbed, 90 Y is eluted with lithium citrate. During this process, 90 Y is bonded in a citrate complex which, having a negative charge, is subsequently trapped by an anex. A guard column is inserted before the anex column to trap any traces of 90 Sr. 90 Y is eluted from the anex in the yttrium chloride form by using dilute hydrochloric acid. The product from the generator can be used for the preparation of [ 90 Y] - Fe colloid injection or [ 90 Y] - yttrium citrate injection for intra-articular application or for the development of monoclonal antibodies and peptides

  20. Production of yttrium

    International Nuclear Information System (INIS)

    Day, J.G.

    1980-01-01

    A process is described for the production of yttrium metal, or of an alloy comprising a major proportion of yttrium, in which calcium (metal) and yttrium fluoride are reacted together by use of a submerged electric arc in a molten slag. (author)

  1. Cooling rate dependence of structural order in Al{sub 90}Sm{sub 10} metallic glass

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yang [Hefei National Laboratory for Physical Sciences at the Microscale and Department of Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Ames Laboratory, US Department of Energy, Ames, Iowa 50011 (United States); Zhang, Yue; Zhang, Feng, E-mail: fzhang@ameslab.gov; Ye, Zhuo [Ames Laboratory, US Department of Energy, Ames, Iowa 50011 (United States); Ding, Zejun [Hefei National Laboratory for Physical Sciences at the Microscale and Department of Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Wang, Cai-Zhuang [Ames Laboratory, US Department of Energy, Ames, Iowa 50011 (United States); Department of Physics, Iowa State University, Ames, Iowa 50011 (United States); Ho, Kai-Ming [Hefei National Laboratory for Physical Sciences at the Microscale and Department of Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Ames Laboratory, US Department of Energy, Ames, Iowa 50011 (United States); Department of Physics, Iowa State University, Ames, Iowa 50011 (United States); International Center for Quantum Design of Functional Materials (ICQD), and Synergetic Innovation Center of Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2016-07-07

    The atomic structure of Al{sub 90}Sm{sub 10} metallic glass is studied using molecular dynamics simulations. By performing a long sub-T{sub g} annealing, we developed a glass model closer to the experiments than the models prepared by continuous cooling. Using the cluster alignment method, we found that “3661” cluster is the dominating short-range order in the glass samples. The connection and arrangement of “3661” clusters, which define the medium-range order in the system, are enhanced significantly in the sub-T{sub g} annealed sample as compared with the fast cooled glass samples. Unlike some strong binary glass formers such as Cu{sub 64.5}Zr{sub 35.5}, the clusters representing the short-range order do not form an interconnected interpenetrating network in Al{sub 90}Sm{sub 10,} which has only marginal glass formability.

  2. Polymer based microspheres of aceclofenac as sustained release parenterals for prolonged anti-inflammatory effect

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Manpreet; Sharma, Sumit; Sinha, VR, E-mail: sinha_vr@rediffmail.com

    2017-03-01

    Poly(lactic-co-glycolic acid) (PLGA) (75:25) and polycaprolactone (PCL) microspheres were fabricated for prolonged release of aceclofenac by parenteral administration. Microspheres encapsulating aceclofenac were designed to release the drug at controlled rate for around one month. Biodegradable microspheres were prepared by solvent emulsification evaporation method in different polymer:drug ratios (1:1, 2:1 and 3:1). After drug loading, PLGA and PCL microspheres showed a controlled size distribution with an average size of 11.75 μm and 3.81 μm respectively and entrapment efficiency in the range of 90 ± 0.72% to 91.06 ± 4.01% with PLGA and 83.01 ± 2.13% to 90.4 ± 2.11% with PCL. Scanning electron microscopy has confirmed good spherical structures of microspheres. The percent yield of biodegradable polymeric microspheres ranged between 30.95 ± 10.14% to 92.84 ± 3.15% and 47.33 ± 4.72% to 80 ± 3.60% for PLGA and PCL microspheres respectively. PLGA microspheres followed Higuchi release pattern while Korsmeyer-Peppas explained the release pattern of PCL microspheres. Stability studies of microspheres were also carried out by storing the preparations at 2-8 °C for 30, 60 and 90 days and evaluating them for entrapment efficiency, residual drug content and polymer drug compatability. In-vivo studies showed significant anti-inflammatory activity of microspheres upto 48 hours using the carrageenan induced rat paw oedema model. - Highlights: • PLGA and PCL polymeric microspheres for parenteral prolonged drug delivery system were formulated. • Polymeric microspheres were characterized physically and drug excipient incompatability. • Three months accelerated stability studies were carried for drug loaded polymeric microspheres. • Pharmacodynamic studies prove the rationality of sustained therapeutic effect of designed drug delivery system.

  3. Recent advances in Pt coating of microspheres by a batch magnetron sputtering process

    International Nuclear Information System (INIS)

    Hsieh, E.J.; Meyer, S.F.

    1980-01-01

    Some proposed inertial confinement fusion targets require high-Z, high density metal coatings on glass microspheres. Platinum, which satisfies the high-Z and density requirements, can be coated onto microspheres with a batch magnetron sputtering process incorporating oxygen as a dopant gas to prevent the microspheres from sticking. This paper outlines recent progress in three areas: First, the coating process has been improved; second, the oxygen content and resistivity of the oxygen doped platinum films are analyzed; and third, the roles oxygen may play in reducing microsphere sticking during sputtering are discussed in regard to cold welding, Van der Waals bonding, electrostatic sticking, and sintering

  4. Retrospective analysis of cystic craniopharyngeomas after intracavital irradiation with yttrium-90 colloid

    International Nuclear Information System (INIS)

    Urbanova, E.; Vizda, J.; Netikova, M.; Kafka, P.; Jakubec, J.

    2002-01-01

    Aim: The authors report about follow up the patients after intracavitary irradiation for cystic craniopharyngeoma. Material and Methods: For retrospective analysis 15 patients were selected. The volume of the cyst was determined by CT or MRI. For dosimetry Backlund's formula was used. The cumulative dose to the inner surface of the cyst wall was about 250Gy. 90 Yttrium silicate colloid was administered directly during stereotactically (CT guided) surgery or through the Ommaya drainage system. Control scintigraphy was performed 2-3 hours after 90 Y injection with gamma camera to detect possible leakage of the radioisotope. None of our patients showed evidence of this. In addition to this, the patients were checked daily to pay attention to visual function, neurological condition and possible meningeal irritation. Results: Cyst shrinkage was monitored by repeated CT examinations. CT cyst volume measurement analysed all patients before and 1,2,3 and 5 years after the treatment. In our study 45% of cysts decreased in volume during 4 month, shrinkage of the initial cyst volume was 75% after 1 year. The cyst disappeared nearly totally in 5 patients. Only 3 cyst remain unchanged and 90 Y treatment was repeated. No patients developed a visual field defect or evidence of hypothalamic dysfunction after the treatment. The neuro-opthalmological state completely recovered in 2 patients and improved in 5 patients. The prognosis was good only when an intact optic discs in time of the treatment was present. In some cases the radioisotope was implanted at a late stage of the disease without the opthalmological and neurological improvement. One patient died due to pulmonary embolism one week after the procedure. One patient died within a one year of the treatment from complications related to a solid cystic recurrence. One of typical signs for recurrence was worsening of neuro-opthalmological state. Conclusion: From our results this intracavitary 90 Y therapy is minimally invasive

  5. Solvent/non-solvent sintering: a novel route to create porous microsphere scaffolds for tissue regeneration.

    Science.gov (United States)

    Brown, Justin L; Nair, Lakshmi S; Laurencin, Cato T

    2008-08-01

    Solvent/non-solvent sintering creates porous polymeric microsphere scaffolds suitable for tissue engineering purposes with control over the resulting porosity, average pore diameter, and mechanical properties. Five different biodegradable biocompatible polyphosphazenes exhibiting glass transition temperatures from -8 to 41 degrees C and poly (lactide-co-glycolide), (PLAGA) a degradable polymer used in a number of biomedical settings, were examined to study the versatility of the process and benchmark the process to heat sintering. Parameters such as: solvent/non-solvent sintering solution composition and submersion time effect the sintering process. PLAGA microsphere scaffolds fabricated with solvent/non-solvent sintering exhibited an interconnected porosity and pore size of 31.9% and 179.1 mum, respectively which was analogous to that of conventional heat sintered PLAGA microsphere scaffolds. Biodegradable polyphosphazene microsphere scaffolds exhibited a maximum interconnected porosity of 37.6% and a maximum compressive modulus of 94.3 MPa. Solvent/non-solvent sintering is an effective strategy for sintering polymeric microspheres, with a broad spectrum of glass transition temperatures, under ambient conditions making it an excellent fabrication route for developing tissue engineering scaffolds and drug delivery vehicles. (c) 2007 Wiley Periodicals, Inc.

  6. Evaluation of the Thermosensitive Release Properties of Microspheres Containing an Agrochemical Compound.

    Science.gov (United States)

    Terada, Takatoshi; Ohtsubo, Toshiro; Iwao, Yasunori; Noguchi, Shuji; Itai, Shigeru

    2017-01-01

    The purpose of this study was to develop a deeper understanding of the key physicochemical parameters involved in the release profiles of microsphere-encapsulated agrochemicals at different temperatures. Microspheres consisting of different polyurethanes (PUs) were prepared using our previously reported solventless microencapsulation technique. Notably, these microspheres exhibited considerable differences in their thermodynamic characteristics, including their glass transition temperature (T g ), extrapolated onset temperature (T o ) and extrapolated end temperature (T e ). At test temperatures below the T o of the PU, only 5-10% of the agrochemical was rapidly released from the microspheres within 1 d, and none was released thereafter. However, at test temperatures above the T o of the PU, the rate of agrochemical release gradually increased with increasing temperatures, and the rate of release from the microspheres was dependent on the composition of the PU. Taken together, these results show that the release profiles of the microspheres were dependent on their thermodynamic characteristics and changes in their PU composition.

  7. 90Sr- 90Y and 89Sr beta radioactivity measurement in milk samples using a proportional counter

    International Nuclear Information System (INIS)

    Mananes, A.; Perez Santos, C.; Martinez Churiaque, F.

    1987-01-01

    A thin window glas flow proportional counter is used to measure the 90 Sr- 90 Y and 89 Sr beta radioactivity in milk samples. A chemical procedure is used to separate strontium-yttrium from the other radionuclides present in milk. A calculation of the total efficiency of the system is performed which includes an empirical estimation of the backscattering factor. The calibration of the whole process allows the determination of the 90 Sr activity within 10% relative error in spite of uncertainties in the recovery yields of strontium and yttrium. No 89 Sr activity has been detected, and the mean value obtained for the 90 Sr activity in nine milk samples of Cantabria is 0.115 Bq/1 with a minimum detectable activity of 0.0105 Bq. (author) 18 refs

  8. Molecular dynamics simulations and structural descriptors of radioisotope glass vectors for in situ radiotherapy.

    Science.gov (United States)

    Christie, Jamieson K; Tilocca, Antonio

    2012-10-18

    The low solubility (high durability) of yttrium aluminosilicate (YAS) glass is one of its most important properties for use in in situ radiotherapy. Simple parameters, such as silica or yttria content or network connectivity, are not sufficient to rationalize the dependence of the solubility on the glass composition observed experimentally. We performed classical molecular dynamics (MD) simulations of eight different YAS glasses of known solubility and analyzed the MD trajectories to identify specific structural features that are correlated and can be used to predict the solubility. We show that the (Si-)O-Si coordination number CN(SiOSi), the yttrium-yttrium clustering ratio R(YY), and the number of intratetrahedral O-Si-O bonds per yttrium atom N(intra) can be combined into a single structural descriptor s = f(CN(SiOSi),R(YY),N(intra)) with a high correlation with the solubility. The parameter s can thus be calculated from MD simulations and used to predict the solubility of YAS compositions, allowing one to adjust them to the range required by radiotherapy applications. For instance, its trend shows that high-silica- and low-yttria-content YAS glasses should be sufficiently durable for the radiotherapy application, although additional clinical considerations may set a lower limit to the yttria content.

  9. Coprecipitation of yttrium and aluminium hydroxide for preparation of yttrium aluminium garnet

    NARCIS (Netherlands)

    Vrolijk, J.W.G.A.; Willems, J.W.M.M.; Metselaar, R.

    1990-01-01

    Coprecipitation of yttrium and aluminium hydroxide for the preparation of pure yttrium aluminium garnet (YAG) powder with small grain size is the subject of this study. Starting materials are sulphates and chlorides of yttrium and aluminium. To obtain pure YAG (Y3Al5O12), the pH during flocculation

  10. Contrast enhancement of microsphere-assisted super-resolution imaging in dark-field microscopy

    Science.gov (United States)

    Zhou, Yi; Tang, Yan; Deng, Qinyuan; Zhao, Lixin; Hu, Song

    2017-08-01

    We report a method of boosting the imaging contrast of microsphere-assisted super-resolution visualization by utilizing dark-field illumination (DFI). We conducted experiments on both 10-µm-diameter silica (SiO2) microspheres with refractive index n ∼ 1.46 under no and partial immersion in ethyl alcohol (n ∼ 1.36) and 20-µm-diameter barium titanate glass (BTG, n ∼ 1.9) microspheres with full immersion to show the super-resolution capability. We experimentally demonstrated that the imaging contrast and uniformity were extraordinarily improved in the DFI mode. The intensity profiles in the visualization also numerically confirm the enhanced sharpness for a better imaging quality when applying DFI.

  11. Production of microspheres labeled with holmium-166 for liver cancer therapy: the preliminary experience at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Costa, Renata F.; Azevedo, Mariangela B.M.; Nascimento, Nanci; Sene, Frank F.; Martinelli, Jose R.; Osso Junior, Joao A.

    2009-01-01

    Microspheres labeled with therapeutic radionuclides for malignancies of liver are widely used in many countries. The internal radionuclide therapy uses a permanently implanted device, such as Therasphere R or SIR-Spheres R , or a biodegradable device that provides structural support for the radionuclide of choice and causes the tumor reduction. Three different types of material supports have been investigated, i.e., biodegradable polymer-based, glass-based and resin-based microspheres. Nowadays there is a project concerning the labeling of these 3 materials with 166 Ho being developed at IPEN-CNEN/SP and coordinated by the Radiopharmacy Directory. 166 Ho(t 1/2 =26.8 h) is a beta minus emitter (E max =1.84 MeV), with right properties for radiotherapy and can be produced with the low power Brazilian Nuclear Reactor IEA-R1m. The aim of this work is to describe the stage of development of this project. The initial experience used resin-based microspheres, a cation exchange resin labeled with 166 Ho, it showed the essential characteristics for liver therapy. Preliminary results of the preparation of glass-based microspheres labeled with 165 Ho showed that 5% of Ho 2 O 3 was incorporated in an aluminosilicate glass, through the process of spheronization by flame, which produced spherical microspheres with 20-40μm particle size. The preparation of biodegradable material, polymer-based microspheres, is in its initial stage and the objective is to prepare and label with 165 Ho different polymer-based microspheres. These combined efforts have been done to offer a national radiotherapeutic product for the the Brazilian nuclear medicine community at fair value and also to offer a viable possibility of treatment for patients affected by liver malignancies. (author)

  12. Production of microspheres labeled with holmium-166 for liver cancer therapy: the preliminary experience at IPEN/CNEN-SP

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Renata F.; Azevedo, Mariangela B.M.; Nascimento, Nanci; Sene, Frank F.; Martinelli, Jose R.; Osso Junior, Joao A., E-mail: renatafcosta@usp.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Microspheres labeled with therapeutic radionuclides for malignancies of liver are widely used in many countries. The internal radionuclide therapy uses a permanently implanted device, such as Therasphere{sup R} or SIR-Spheres{sup R}, or a biodegradable device that provides structural support for the radionuclide of choice and causes the tumor reduction. Three different types of material supports have been investigated, i.e., biodegradable polymer-based, glass-based and resin-based microspheres. Nowadays there is a project concerning the labeling of these 3 materials with {sup 166}Ho being developed at IPEN-CNEN/SP and coordinated by the Radiopharmacy Directory. {sup 166}Ho(t{sub 1/2}=26.8 h) is a beta minus emitter (E{sub max}=1.84 MeV), with right properties for radiotherapy and can be produced with the low power Brazilian Nuclear Reactor IEA-R1m. The aim of this work is to describe the stage of development of this project. The initial experience used resin-based microspheres, a cation exchange resin labeled with {sup 166}Ho, it showed the essential characteristics for liver therapy. Preliminary results of the preparation of glass-based microspheres labeled with {sup 165}Ho showed that 5% of Ho{sub 2}O{sub 3} was incorporated in an aluminosilicate glass, through the process of spheronization by flame, which produced spherical microspheres with 20-40mum particle size. The preparation of biodegradable material, polymer-based microspheres, is in its initial stage and the objective is to prepare and label with {sup 165}Ho different polymer-based microspheres. These combined efforts have been done to offer a national radiotherapeutic product for the the Brazilian nuclear medicine community at fair value and also to offer a viable possibility of treatment for patients affected by liver malignancies. (author)

  13. Semi-quantitative analysis of post-transarterial radioembolization 90Y Microsphere position emission tomography combined with computed tomography (PET/CT) images in advance liver malignancy: Comparison with 99mTc macroaggregated albumin (MAA) single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Rhee, Seung Hong; Kim, Sung Eun; Cho, Jae Hyuk; Park, Ju Kyung; Kim, Yun Hwan; Choe, Jae Gol; Eo, Jae Seon; Park, So Yeon; Lee, Eun Sub

    2016-01-01

    The purpose of this study is to evaluate the correlation between pretreatment planning technetium-99m ( 99 mTc) macroaggregated albumin (MAA) SPECT images and posttreatment transarterial radioembolization (TARE) yttirum-90 ( 90 Y) PET/CT images by comparing the ratios of tumor-to-normal liver counts. Fifty-two patients with advanced hepatic malignancy who underwent 90 Y microsphere radioembolization from January 2010 to December 2012 were retrospectively reviewed. Patients had undergone 99 mTc MAA intraarterial injection SPECT for a pretreatment evaluation of microsphere distribution and therapy planning. After the administration of 90 Y microspheres, the patients underwent posttreatment 90 Y PET/CT within 24 h. For semiquantitative analysis, the tumor-to-normal uptake ratios in 90 Y PET/CT (TNR-yp) and 99 mTc MAA SPECT (TNR-ms) as well as the tumor volumes measured in angiographic CT were obtained and analyzed. The relationship of TNR-yp and TNR-ms was evaluated by Spearman's rank correlation and Wilcoxon's matched pairs test. In a total of 79 lesions of 52 patients, the distribution of microspheres was well demonstrated in both the SPECT and PET/CT images. A good correlation was observed of between TNR-ms and TNR-yp (rho value = 0.648, p < 0.001). The TNR-yp (median 2.78, interquartile range 2.43) tend to show significantly higher values than TNR-ms (median 2.49, interquartile range of 1.55) (p = 0.012). The TNR-yp showed weak correlation with tumor volume (rho = 0.230, p = 0.041). The 99mTc MAA SPECT showed a good correlation with 90 Y PET/CT in TNR values, suggesting that 99 mTc MAA can be used as an adequate pretreatment evaluation method. However, the 99 mTc MAA SPECT image consistently shows lower TNR values compared to 90Y PET/CT, which means the possibility of underestimation of tumorous uptake in the partition dosimetry model using 99 mTc MAA SPECT. Considering that 99 mTc MAA is the only clinically available surrogate marker

  14. Evaluation of aluminosilicate glass sintering during differential scanning calorimetry

    International Nuclear Information System (INIS)

    Souza, Juliana Pereira de

    2015-01-01

    In this work a difference in the baseline in differential scanning calorimetry analyses, observed in a work where aluminosilicate glasses microspheres containing Ho were studied for application in selective internal radiotherapy as hepatocellular carcinoma treatment, was studied. The glasses with nominal composition 53,7 SiO 2 .10,5 Al 2 O 3 . 35,8 MgO in %mol were produced from traditional melting. The first obtained were milled and sieved in the range of 45 a 63 μm. The material was used to produce glass microspheres by the gravitational fall method. The glass powder and the microspheres were characterized by X ray fluorescence spectrometry, laser diffraction, X ray diffraction, differential scanning calorimetry, differential thermal analysis, thermogravimetry, mass spectrometry, and scanning electron microscopy. After the thermal analyses, pellets were formed in the crucibles and were analyzed by scanning electron microscopy, X ray diffraction, and He pycnometry. The difference in the baseline was associated to the viscous flow sintering process and happens because of the decrease in the detected heat flow due to the sample shrinkage. Other events as concurrent crystallization with the sintering process were also studied. (author)

  15. Unactivated yttrium tantalate phosphor

    International Nuclear Information System (INIS)

    Reddy, V.B.; Cheung, H.K.

    1992-01-01

    This patent describes an unactivated yttrium tantalate phosphor having M prime monoclinic structure and containing one or more additives of Rb and Al in an amount of between about 0.001 to 0.1 moles per mole of yttrium tantalate to improve brightness under X-radiation. This patent also describes an unactivated yttrium tantalate phosphor having M prime monoclinic structure and containing additives of Sr in an amount of between 0.001 to 0.1 moles per mole of yttrium tantalate and one or more of Rb and Al in an amount of between 0.001 to 0.1 moles per mole of yttrium tantalate the phosphor exhibiting a greater brightness under X-radiation than the phosphor absent Rb and Al

  16. Evaluation of a pyrex glass shield for the dose reduction in extremities to manipulate a 90 Sr- 90 Y generator

    International Nuclear Information System (INIS)

    Ayra P, F.E.; Xiques C, A.; Torres B, M.B.

    2006-01-01

    The production of Y-90 of high activity it specifies (free of payee) for their use in radioimmunotherapy uses the Strontium 90 as isotope source. Depending on the method employee for the separation of both isotopes several types of generators are described in different bibliographies. The column generator used in the facilities of the Center of Isotopes requires of a frequent manipulation causing significant dose in the skin of the extremities due to the exhibition to the radiation beta of high energy. The properties of the shieldings for this radiation type have been well studied Y they consist in several publications. To be in correspondence with requirements of radiological protection in the Cuban legislation, the column was covered with a tube of glass pyrex of 5 mm of thickness and it was monitored the exposure with an ionization chamber. At the own time, the shielding using the Monte Carlo method was evaluated. It was used the MCNP 4C code to simulate the absorption of the beta particles generated in the process of disintegration of the Sr-90 and Y-90 in the glass shielding. The column generator and the fluence of beta particles were modeled in different points inside the shielding to determine if the experimentally measured values correspond to electrons that were not absorbed or to the weak stopping radiation generated in the glass due to the deceleration of these particles. A cylinder of 4 mm of diameter simulates the source (it dilutes) and a tube of walls of 6 mm of thickness simulates the shielding more the wall of the column around the generator. This it was divided in cells of 1 mm of thickness and the energy deposited in them was evaluated. The results show that all the electrons generated in the source are absorbed in the shielding and the exposure rates decrease in more of 78 times using the 5 mm of pyrex glass. The doses in extremities to the operators of the generator don't surpass the 70 mSv by year that is the dose restriction imposed in the

  17. [Preparation of citrulline microspheres by spray drying technique for colonic targeting].

    Science.gov (United States)

    Bahri, S; Zerrouk, N; Lassoued, M-A; Tsapis, N; Chaumeil, J-C; Sfar, S

    2014-03-01

    Citrulline is an amino acid that becomes essential in situations of intestinal insufficiency such as short bowel syndrome. It is therefore interesting to provide the patients with dosage forms for routing citrulline to the colon. The aim of this work is to formulate microspheres of citrulline for colonic targeting by the technique of spray drying. Eudragit(®) FS 30D was selected as polymer to encapsulate citrulline using the spray drying technique. Citrulline and Eudragit(®) FS 30D were dissolved in water and ethanol, respectively. The aqueous and the ethanolic solutions were then mixed in 1:2 (v/v) ratio. Microspheres were obtained by nebulizing the citrulline-Eudragit(®) FS 30D solution using a Mini spray dryer equipped with a 0.7mm nozzle. The microspheres have been formulated using citrulline and Eudragit(®) FS 30D. The size distribution of microspheres was determined by light diffraction. The morphology of the microspheres was studied by electron microscopy. Manufacturing yields, encapsulation rate and dissolution profiles were also studied. The microspheres obtained had a spherical shape with a smooth surface and a homogeneous size except for the microspheres containing the highest concentration of polymer (90 %). The formulation showed that the size and morphology of the microspheres are influenced by the polymer concentration. Manufacturing yields were about 51 % but encapsulation rate were always very high (above 90 %). The in vitro dissolution study showed that the use of the Eudragit(®) FS 30D under these conditions is not appropriate to change the dissolution profile of the citrulline. This technique has led to the formulation of microspheres with good physical properties in terms of morphology and size. The compression of the microspheres should help to control citrulline release for colonic targeting. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  18. Fiber pigtailed thin wall capillary coupler for excitation of microsphere WGM resonator.

    Science.gov (United States)

    Wang, Hanzheng; Lan, Xinwei; Huang, Jie; Yuan, Lei; Kim, Cheol-Woon; Xiao, Hai

    2013-07-01

    In this paper, we demonstrate a fiber pigtailed thin wall capillary coupler for excitation of Whispering Gallery Modes (WGMs) of microsphere resonators. The coupler is made by fusion-splicing an optical fiber with a capillary tube and consequently etching the capillary wall to a thickness of a few microns. Light is coupled through the peripheral contact between inserted microsphere and the etched capillary wall. The coupling efficiency as a function of the wall thickness was studied experimentally. WGM resonance with a Q-factor of 1.14 × 10(4) was observed using a borosilicate glass microsphere with a diameter of 71 μm. The coupler operates in the reflection mode and provides a robust mechanical support to the microsphere resonator. It is expected that the new coupler may find broad applications in sensors, optical filters and lasers.

  19. Embolisation of the Gastroduodenal Artery is Not Necessary in the Presence of Reversed Flow Before Yttrium-90 Radioembolisation

    Energy Technology Data Exchange (ETDEWEB)

    Daghir, Ahmed A., E-mail: ahmeddaghir@doctors.net.uk [Imperial College Healthcare NHS Trust, Department of Radiology (United Kingdom); Gungor, Hatice [Imperial College Healthcare NHS Trust, Department of Oncology (United Kingdom); Haydar, Ali A. [Barts and the London NHS Trust, Department of Radiology (United Kingdom); Wasan, Harpreet S. [Imperial College Healthcare NHS Trust, Department of Oncology (United Kingdom); Tait, Nicholas P. [Imperial College Healthcare NHS Trust, Department of Radiology (United Kingdom)

    2012-08-15

    Introduction: The gastroduodenal artery (GDA) is usually embolised to avoid nontarget dispersal before yttrium-90 (Y{sup 90}) radioembolisation to treat liver metastases. In a minority of patients, there is retrograde flow in the GDA. The purpose of this study was to determine if there is any increased risk from maintaining a patent GDA in patients with reversed flow. Materials and Methods: A retrospective review was performed of all patients undergoing Y{sup 90} radioembolisation at our institution. The incidence of toxicities arising from nontarget radioembolisation by way of the GDA (gastric/duodenal ulceration, gastric/duodenal bleeding, and pancreatitis) and death occurring within 2 months of treatment were compared between the reversed and the antegrade GDA groups. Results: Ninety-two patients underwent preliminary angiography. Reversed GDA flow was found on angiography in 14.1% of cases; the GDA was not embolised in these patients. The GDA was coiled in 55.7% of patients with antegrade GDA flow to prevent inadvertent dispersal of radioembolic material. There was no increased toxicity related to nontarget dispersal by way of the GDA, or increased early mortality, in patients with reversed GDA flow (P > 0.05). Conclusion: In patients with reversed GDA flow, maintenance of a patent GDA before administration of Y{sup 90} radioembolisation does not increase the risk of toxicity from nontarget dispersal. Therapeutic injection, with careful monitoring to identify early vascular stasis, may be safely performed beyond the origin of the patent GDA. A patent GDA with reversed flow provides forward drive for infused particles and may allow alternative access to the hepatic circulation.

  20. Development of methodology for the preparation of 90Sr-90Y generators

    International Nuclear Information System (INIS)

    Barrio, Graciela; Osso, Joao A.

    2008-01-01

    Among the more attractive radionuclides for therapeutic applications is yttrium-90. Its relatively short half-life (64.0h), maximum beta energy (2.28 MeV) make it well suited for a variety of applications, ranging from the radiolabeling of antibodies for tumor therapy to the production of radiolabeled particles for the treatment of liver malignancies. Yttrium-90 results from the decay of strontium-90 (28y) and decays to a stable daughter ( 90 Zr) and has no γ-ray, what makes this nuclide very attractive for therapeutic applications. 90 Y is produced through a generator system, from the decay of 90 Sr. Before it can safely employed in clinical applications, the 90 Y must be made essentially free of 90 Sr, an isotope known to cause bone marrow suppression. The objective of this work is to develop 90 Sr- 90 Y generator using a cation exchange method resin. This method was the most effects for the separation of 90 Y and 90 Sr. 90 Sr is strongly adsorbed in the resin and 90 Y is eluted in 0.003M EDTA. The generator efficiency and radionuclide control results were also evaluated using 85 Sr (γ-ray emitter). The generator was developed, using AG 50WX8 exchange resin converted to the Na+ form and then conditioned with 0.003M EDTA solution (pH=4.8). The quality control showed that 90 Y had no 8 '5Sr impurities, inside the detection limits of the detector. The results presented here are very promising, showing that the methodology is able to separate the two nuclides, with low quantities of 90 Sr impurity and satisfactory elution yields. (author)

  1. Preparation of nano-hydroxyapatite/poly(l-lactide) biocomposite microspheres

    International Nuclear Information System (INIS)

    Qiu Xueyu; Han Yadong; Zhuang Xiuli; Chen Xuesi; Li Yuesheng; Jing Xiabin

    2007-01-01

    Nano-hydroxyapatite (HA)/poly(l-lactide) (PLLA) composite microspheres with relatively uniform size distribution were prepared by a solid-in-oil-in-water (s/o/w) emusion solvent evaporation method. The encapsulation of the HA nanopaticles in microshperes was significantly improved by grafting PLLA on the surface of the HA nanoparticles (p-HA) during emulsion process. This procedure gave a possibility to obtain p-HA/PLLA composite microspheres with uniform morphology and the encapsulated p-HA nanoparticle loading reached up to 40 wt% (33 wt% of pure HA) in the p-HA/PLLA composite microspheres. The microstructure of composite microspheres from core-shell to single phase changed with the variation of p-HA to PLLA ratios. p-HA/PLLA composite microspheres with the diameter range of 2-3 μm were obtained. The entrapment efficiency of p-HA in microspheres could high up to 90 wt% and that of HA was only 13 wt%. Surface and bulk characterizations of the composite microspheres were performed by measurements such as wide angle X-ray diffraction (WAXD), thermal gravimetric analysis (TGA), environmental scanning electron microscope (ESEM) and transmission electron microscopy (TEM)

  2. Sputter coating of microspherical substrates by levitation

    Science.gov (United States)

    Lowe, A.T.; Hosford, C.D.

    Microspheres are substantially uniformly coated with metals or nonmetals by simltaneously levitating them and sputter coating them at total chamber pressures less than 1 torr. A collimated hole structure comprising a parallel array of upwardly projecting individual gas outlets is machined out to form a dimple. Glass microballoons,, which are particularly useful in laser fusion applications, can be substantially uniformly coated using the coating method and apparatus.

  3. Pharmacokinetics of chimeric L6 conjugated to indium-111- and yttrium-90-DOTA-peptide in tumor-bearing mice

    International Nuclear Information System (INIS)

    DeNardo, S.J.; Zhong, G.R.; Salako, Q.

    1995-01-01

    A bifunctional chelating agent, DOTA-Gly 3 -L-(p-isothiocyanato)-phenylalanine amide (DOTA-peptide-NCS), was studied in nude mice bearing human breast cancer xenografts (HBT 3477) to determine its potential for radioimmunoconjugate therapy. Indium-111 and yttrium-90 were attached to an anti-adenocarcinoma chimeric L6 (ChL6) monoclonal antibody (MAb) after pre-chelation to the DOTA-peptide-NCS and the desired neutral radiochelates were obtained by purification. The unique characteristic of the DOTA-peptide-NCS to form neutral complexes with trivalent metals was utilized to separate the resulting 111 In and 90 Y radiochelates from excess chelating agent and other anionic by-products resulting from metal impurities. The purified radiochelates were then conjugated to ChL6. The paramacokinetics of 111 In- and 90 Y-DOTA-peptide-ChL6 were obtained for 5 days after injection in nude mice bearing HBT 3477 xenographs. The results were compared with the pharmacokinetics of 125 I-ChL6 obtained in the same mouse model. The whole-body clearance of 125 I-ChL6, 90 Y-and 111 In-DOTA-peptide-ChL6 was monoexponential with biologic half-times of 92, 104 and 160 hr, respectively. Blood clearances of the three radiopharmaceuticals were biphasic. The radiometal immunoconjugates had greater tumor uptake and slower clearances. Indium-111- and 90 Y-DOTA-peptide-ChL6 can be produced at high specific activity with fewer than one chelate per MAb by using a pre-labeling method that permits radiochelate purification by charge selection. Studies in mouse xenografts indicate that tumor uptake in enhanced and a favorable therapeutic index is achieved using these agents. 29 refs., 7 figs., 2 tabs

  4. Safety of Repeated Yttrium-90 Radioembolization

    International Nuclear Information System (INIS)

    Lam, Marnix G. E. H.; Louie, John D.; Iagaru, Andrei H.; Goris, Michael L.; Sze, Daniel Y.

    2013-01-01

    Purpose: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver’s cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. Methods: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51–71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia). Adverse events were graded during a standardized follow-up. In addition, the correlation between the occurrence of RE-induced liver disease (REILD) and multiple variables was investigated in univariate and multivariate analyses in all 247 patients who received RE. Results: Two patients died shortly after the second treatment (at 84 and 107 days) with signs and symptoms of REILD. Both patients underwent whole liver treatment twice (cumulative doses 3.08 and 2.66 GBq). The other 6 patients demonstrated only minor toxicities after receiving cumulative doses ranging from 2.41 to 3.88 GBq. All patients experienced objective tumor responses. In the whole population, multifactorial analysis identified three risk factors associated with REILD: repeated RE (p = 0.036), baseline serum total bilirubin (p = 0.048), and baseline serum aspartate aminotransferase (p = 0.043). Repeated RE proved to be the only independent risk factor for REILD in multivariate analysis (odds ratio 9.6; p = 0.002). Additionally, the administered activity per target volume (in GBq/L) was found to be an independent risk factor for REILD, but only in whole liver treatments (p = 0.033). Conclusion: The risk of REILD appears to be elevated for repeated RE. Objective tumor responses were observed, but establishment of safety limits will require improvement in dosimetric measurement and prediction

  5. Safety of Repeated Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Marnix G. E. H.; Louie, John D. [Stanford University School of Medicine, Division of Interventional Radiology (United States); Iagaru, Andrei H.; Goris, Michael L. [Stanford University School of Medicine, Division of Nuclear Medicine (United States); Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-10-15

    Purpose: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver's cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. Methods: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51-71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia). Adverse events were graded during a standardized follow-up. In addition, the correlation between the occurrence of RE-induced liver disease (REILD) and multiple variables was investigated in univariate and multivariate analyses in all 247 patients who received RE. Results: Two patients died shortly after the second treatment (at 84 and 107 days) with signs and symptoms of REILD. Both patients underwent whole liver treatment twice (cumulative doses 3.08 and 2.66 GBq). The other 6 patients demonstrated only minor toxicities after receiving cumulative doses ranging from 2.41 to 3.88 GBq. All patients experienced objective tumor responses. In the whole population, multifactorial analysis identified three risk factors associated with REILD: repeated RE (p = 0.036), baseline serum total bilirubin (p = 0.048), and baseline serum aspartate aminotransferase (p = 0.043). Repeated RE proved to be the only independent risk factor for REILD in multivariate analysis (odds ratio 9.6; p = 0.002). Additionally, the administered activity per target volume (in GBq/L) was found to be an independent risk factor for REILD, but only in whole liver treatments (p = 0.033). Conclusion: The risk of REILD appears to be elevated for repeated RE. Objective tumor responses were observed, but establishment of safety limits will require improvement in dosimetric measurement and prediction.

  6. Long-lived impurities of 90Y-labeled microspheres, TheraSphere and SIR-spheres, and the impact on patient dose and waste management.

    Science.gov (United States)

    Metyko, John; Williford, John M; Erwin, William; Poston, John; Jimenez, Sandra

    2012-11-01

    Yittrium-90 microsphere brachytherapy procedures have increased in number due to their efficacy in treating some unresectable metastatic liver tumors. The discovery of long-lived impurities in two microsphere products, first reported between 2006 and 2007, has resulted in some radiation safety concerns. Since then, microsphere production processes have been refined, which reportedly lead to a reduction in detectable by-products. In this study unused vials of TheraSphere and SIR-Spheres, manufactured in early January 2011, were analyzed to identify and quantify the low-level radioactive impurities. Absorbed dose calculations were performed to assess the potential increased dose to the patient due to long-lived impurities. Results showed that while the SIR-Spheres vials contained no detectable impurities (contrary to other published results in the literature), the TheraSphere vials contained 17 radionuclides in one sample and 15 in the other. The dominant impurities were Y and Y, with specific activities ranging from 0.99 ± 3.40 × 10 kBq mg to 6.30 ± 0.40 kBq mg at vendor assay date. Other impurities were on the order of Bq mg. Based on Medical Internal Radiation Dose (MIRD) liver and lung dose estimates, the long-lived impurities would be expected to increase an administered dose by less than 0.1% from the prescribed dose.

  7. Simplified method of analysis of Strontium-90 in milk

    International Nuclear Information System (INIS)

    Suomela, J.

    1987-06-01

    The milk sample is freeze-dried and the milk powder ignited. The ash is dissolved in hydrochloric acid and yttrium is extracted from the solution by 5% HDEHP (dioctyl phosforic acid). After re-extraction in nitric acid the Cherenkov radiation of yttrium 90 is measured in a low beta liquid scintillation counter. (O.S.)

  8. Spectrophotometric determination of yttrium with 2-(2-thiazolylazo)-5-dimethylaminophenol

    International Nuclear Information System (INIS)

    Tsurumi, Chikao; Furuya, Keiichi.

    1975-01-01

    Spectrophotometric determination of small amounts of yttrium with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM) in the presence of zephiramine was investigated. The recommended procedures were as follows; 2.0 ml of water, 7.0 ml of TAM-methanolic solution (2x10 -4 mol/l) and 2.0 ml of zephiramine-aqueous solution (1x10 -2 mol/l) were added to a solution containing less than 35 μg of yttrium and its pH was adjusted to 8.0 with 0.1 mol/l ammonium chloride-0.1 mol/l ammonium hydroxide solution. The solution was transferred to a 25 ml volumetric flask and diluted to the mark with water. After 20 minutes, the absorbance at 575 nm against a reagent blank was measured. The color of yttrium-TAM complex is reddish-violet in the presence of zephiramine and is stable for 90 minutes after color development. The yttrium-TAM complex shows an absorption maximum at 575 nm. The absorbance at 575 nm is constant in a pH range from 7.5 to 8.3. The molar extinction coefficient at this wavelength is 7.2x10 4 l.mol -1 .cm -1 . The band obeys Beer's law up to the concentration of 1.4 μg/ml of yttrium. The molar ratio of yttrium to TAM in the complex is 1 : 2. A number of ions interfere with the determination can be masked by the addition of various masking agents and removed in terms of trioctylamine-xylene extraction. Manganese, tantalum, tin(II), citrate and tartrate ions interfere with the determination. (auth.)

  9. Study of the spheronization process of glass particles by the gravitational falling process for internal selective radiotherapy

    International Nuclear Information System (INIS)

    Barros Filho, E.C.; Martinelli, J.R.; Sene, F.F.

    2011-01-01

    The internal selective radiotherapy is an alternative to treat hepatocellular carcinoma. Glass microspheres containing β - emitter radionuclide are introduced in the liver, and they are housed preferentially in the region where the cancer cells are located. The microspheres are trapped in the arterioles which feed the tumors, and the β - particles annihilate the cancer cells. The glass particles must be spherical to avoid unnecessary bleeding, and the particle size must be restricted to a range which optimizes the blocking effect and avoid the migration to other parts of the human body. The particle size distribution of microspheres is not easily predicted since the variation of the aspect ratio and the presence of agglomerates can influence the resulting particle size distribution. In the present work, the spheronization process to obtain microspheres from irregular shape glass particles with suitable diameter and shape for radiotherapy treatment is studied. (author)

  10. Crystallization and structural approaches of rare earths aluminosilicate glasses (Ln = La, Y, Sc)

    International Nuclear Information System (INIS)

    Sadiki, N.; Coutures, J.P.; Hennet, L.; Florian, P.; Vaills, Y.; Massiot, D.

    2010-01-01

    The crystallization behaviour of aluminosilicate glasses of lanthanum, yttrium and scandium has been studied by DTA, XRD, SEM-EDX and EPMA analysis. Young modulus E and hardness H have been measured by using nano-indentation and elastic modulus C 11 and C 44 by Brillouin scattering. The Young modulus measured by nano-indentation agree to those determined by Brillouin scattering and those calculated using Makishima-Mackenzie and Rocherulle model's. The results of DTA analysis indicate that (a) the glass transition temperatures T g are higher for yttrium and scandium containing glasses than their lanthanum counterparts, the melting observed in the yttrium glasses and recently in the scandium glasses correspond to the ternary eutectic Ln 2 O 3 -Al 2 O 3 -SiO 2 (Ln = Y, Sc) (b) the thermal stability is strongly related to the ionic radii of the rare earth. The last results obtained on scandium containing glasses confirm this hypothesis. The XRD results show that the nature of the observed crystallized phases is consistent with the phase diagrams. We also have investigated by NMR-MAS of 27 Al (high field- 17.6 T) these glasses. The results indicate that Al(V) species are correlated to the ionic radii of the rare earth. X-rays and neutron scattering experiments have been respectively performed on the high energy diffraction beam lines ID11 and ID15 at ESRF. The interatomic distances and first-shell coordination numbers were determined. The results are consistent with those performed by NMR-MAS. (authors)

  11. Therapy with {sup 90}Y microspheres: radiation protection in new medical therapies; Terapia con microesferas de {sup 90}Y: proteccion radiologica en nuevas terapias medicas

    Energy Technology Data Exchange (ETDEWEB)

    Rojo, Ana; Puerta, Nancy, E-mail: arojo@arn.gob.ar [Autoridad Regulatoria Nuclear (ARN), Buenos Aires (Argentina)

    2013-07-01

    Primary liver cancer is one of the most frequent in the world and with a low cure rate. Radioembolization using 90y spheres is a promising treatment of this pathology and involves the percutaneous vascular application of radioisotope-labeled the order of Micron size particles. The advantages of this technique include the permit administered high doses of radiation to small volumes with low relative toxicity, offer the possibility of treating all the liver including microscopic tumors, and finally, the feasibility of combined with other therapies. Radiation protection in new medical therapies requires justification and optimization, as requirements for their implementation. The application of the principle of optimization in the context of the protection of the patient must be the minimum that it can be reasonably reached compatible with the required doses of treatment dose to healthy tissue. With {sup 90}Y microspheres therapy this optimization applies to the activity of 90y which is administered to the patient, and estimation methods are postulated. in this work are analyzed comparatively these methods, described the early physicists, equations and the limitations of each. Finally, it is concluded that the optimal method to be implemented for the evaluation of the activity of {sup 90}Y manage must be based in a voxel dosimetric model specific for each patient, however, the partitional method may be a good alternative if you don't have the tools to apply the method.

  12. Preparation and drug controlled release of porous octyl-dextran microspheres.

    Science.gov (United States)

    Hou, Xin; Liu, Yanfei

    2015-01-01

    In this work, porous octyl-dextran microspheres with excellent properties were prepared by two steps. Firstly, dextran microspheres were synthesized by reversed-phase suspension polymerization. Secondly, octyl-dextran microspheres were prepared by the reaction between dextran microspheres and ethylhexyl glycidyl ether and freezing-drying method. Porous structure of microspheres was formed through the interaction between octyl groups and organic solvents. The structure, morphology, dry density, porosity and equilibrium water content of porous octyl-dextran microspheres were systematically investigated. The octyl content affected the properties of microspheres. The results showed that the dry density of microspheres decreased from 2.35 to 1.21 g/ml, porosity increased from 80.68 to 95.05% with the octyl content increasing from 0.49 to 2.28 mmol/g. Meanwhile, the equilibrium water content presented a peak value (90.18%) when the octyl content was 2.25 mmol/g. Octyl-dextran microspheres showed high capacity. Naturally drug carriers play an important role in drug-delivery systems for their biodegradability, wide raw materials sources and nontoxicity. Doxorubicin (DOX) was used as a drug model to examine the drug-loading capacity of porous octyl-dextran microspheres. The drug-loading efficiency increased with the increase in microspheres/drug ratio, while the encapsulation efficiency decreased. When microspheres/drug mass ratio was 4/1, the drug-loading efficiency and encapsulation efficiency were 10.20 and 51.00%, respectively. The release rate of DOX increased as drug content and porosity increased. In conclusion, porous octyl-dextran microspheres were synthesized successfully and have the potential to serve as an effective delivery system in drug controlled release.

  13. Production of Monodisperse Cerium Oxide Microspheres with Diameters near 100 µm by Internal Gelation Sol-Gel Methods

    Energy Technology Data Exchange (ETDEWEB)

    Katalenich, Jeffrey A.; Kitchen, Brian B.; Pierson, Bruce

    2018-05-01

    Internal gelation sol-gel methods have used a variety of sphere forming methods in the past to produce metal oxide microspheres, but typically with poor control over the size uniformity at diameters near 100 µm. This work describes efforts to make and measure internal gelation, sol-gel microspheres with very uniform diameters in the 100 – 200 µm size range using a two-fluid nozzle. A custom apparatus was used to form aqueous droplets of sol-gel feed solutions in silicone oil and heat them to cause gelation of the spheres. Gelled spheres were washed, dried, and sintered prior to mounting on glass slides for optical imaging and analysis. Microsphere diameters and shape factors were determined as a function of silicone oil flow rate in a two-fluid nozzle and the size of a needle dispensing the aqueous sol-gel solution. Nine batches of microspheres were analyzed and had diameters ranging from 65.5 ± 2.4 µm for the smallest needle and fastest silicone oil flow rate to 211 ± 4.7 µm for the largest needle and slowest silicone oil flow rate. Standard deviations for measured diameters were less than 8% for all samples and most were less than 4%. Microspheres had excellent circularity with measured shape factors of 0.9 – 1. However, processing of optical images was complicated by shadow effects in the photoresist layer on glass slides and by overlapping microspheres. Based on calculated flow parameters, microspheres were produced in a simple dripping mode in the two-fluid nozzle. Using flow rates consistent with a simple dripping mode in a two-fluid nozzle configuration allows for very uniform oxide microspheres to be produced using the internal-gelation sol-gel method.

  14. Ageing effects in As10Se90 chalcogenide glasses induced by gamma-irradiation

    International Nuclear Information System (INIS)

    Golovchak, R.; Shpotyuk, O.; Shpotyuk, M.; Gorecki, Cz.; Kozdras, A.

    2005-01-01

    The peculiarities of gamma-induced (Co 60 source, 1.85 MGy absorbed dose) ageing phenomena in As 10 Se 90 chalcogenide glasses are investigated for the first time. The analogy between the observed radiation-induced ageing and the thermally induced one in vitreous selenium is emphasized. Like to thermal treatment, gamma-irradiation leads to an increase in the glass transition temperature and the relaxation rate towards a thermodynamic equilibrium of supercooled liquid, the value of this increase being greater in the case of radiation influence

  15. Validation of Extraction Paper Chromatography as a Quality Control Technique for Analysis of Sr-90 in Y-90 Product

    International Nuclear Information System (INIS)

    Nipavan, Poramatikul; Jatupol, Sangsuriyan; Wiranee, Sriweing

    2009-07-01

    Full text: Yttrium-90 (Y-90) is a daughter product of strontium-90 (Sr-90). It is specified that there should be less than 2 micro-curie of Sr-90 in Y-90 radiopharmaceuticals. Since both nuclides are beta emitting and there is always a contamination of Y-90 in Sr-90 sample, validation of the analytical method is necessary. In this study, commercial Y-90 and Sr-85 (a gamma emitting isotope of strontium) were used as daughter and mother nuclides, respectively. Extraction paper chromatography technique and its efficient validation method were investigated. Bis-(2-ethylhexyl) diphosphonate was dropped at the origin of chromatography paper and air dried prior to sample drops. Validation of the separation was done by radio-chromatography scanning of the chromatography paper. Their energy spectra were identified in the spectra mode of Packard Cobra II automatic gamma counter, which can differentiate a pure gamma, a pure beta and a mixture of beta and gamma nuclides. Results showed that yttrium acetate remained fixed at the origin of the chromatography paper while strontium acetate moved to the solvent front when developed in saline. In conclusion, the extraction paper chromatography technique can effectively separate Sr-90 from Y-90

  16. Outcomes of Therasphere Radioembolization for Colorectal Metastases.

    Science.gov (United States)

    Abbott, Andrea M; Kim, Richard; Hoffe, Sarah E; Arslan, Bulent; Biebel, Ben; Choi, Junsung; El-Haddad, Ghassan; Kis, Bela; Sweeney, Jennifer; Meredith, Kenneth L; Almhanna, Khaldoun; Strosberg, Jonathan; Shibata, David; Fulp, William J; Shridhar, Ravi

    2015-09-01

    The liver is the most common site for colorectal cancer (CRC) metastases. Radioembolization with yttrium-90 (Y90) represents an alternative approach in the management of unresectable hepatic colorectal metastases. The objective of this study was to evaluate outcomes after treatment with Y90. A retrospective review of patients undergoing Y90 glass microsphere treatment for metastatic CRC from 2009 to 2013 was conducted. Multivariable analysis (MVA) of factors related to overall survival (OS) was performed using the Cox proportional hazard and OS estimates were calculated using the Kaplan-Meier method. We identified 68 patients. Median and 2-year OS were 11.6 months and 34%. For patients with ≤ 25% hepatic burden of disease (HBD) and 1 chemotherapy regimen, 2-year OS was 63%. Median and 2-year OS for patients with ≤ 25% versus > 25% HBD were 19.6 months and 42% versus 3.4 months and 0% (P 25% HBD, ≥ 3 lines of chemotherapy, and higher CEA were independently prognostic for increased mortality, and resected status of the primary tumor was associated with decreased mortality. The presence of extrahepatic metastases was not prognostic. Toxicities were mild and only 5 patients experienced Grade 3/4 biochemical toxicity. Yttrium-90 was associated with acceptable OS with minimal morbidity in this series. Minimal exposure to chemotherapy and low HBD were found to be associated with better OS, however, even patients with chemotherapy-refractory disease received a benefit from treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Semi-quantitative analysis of post-transarterial radioembolization {sup 90}Y Microsphere position emission tomography combined with computed tomography (PET/CT) images in advance liver malignancy: Comparison with {sup 99m}Tc macroaggregated albumin (MAA) single photon emission computed tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Seung Hong; Kim, Sung Eun; Cho, Jae Hyuk; Park, Ju Kyung; Kim, Yun Hwan; Choe, Jae Gol [Korea University Anam Hospital, Seoul (Korea, Republic of); Eo, Jae Seon; Park, So Yeon; Lee, Eun Sub [Dept. of Nuclear Medicine, Korea University Guro Hospital, Seoul (Korea, Republic of)

    2016-03-15

    The purpose of this study is to evaluate the correlation between pretreatment planning technetium-99m ({sup 99}mTc) macroaggregated albumin (MAA) SPECT images and posttreatment transarterial radioembolization (TARE) yttirum-90 ({sup 90}Y) PET/CT images by comparing the ratios of tumor-to-normal liver counts. Fifty-two patients with advanced hepatic malignancy who underwent {sup 90}Y microsphere radioembolization from January 2010 to December 2012 were retrospectively reviewed. Patients had undergone {sup 99}mTc MAA intraarterial injection SPECT for a pretreatment evaluation of microsphere distribution and therapy planning. After the administration of {sup 90}Y microspheres, the patients underwent posttreatment {sup 90}Y PET/CT within 24 h. For semiquantitative analysis, the tumor-to-normal uptake ratios in {sup 90}Y PET/CT (TNR-yp) and {sup 99}mTc MAA SPECT (TNR-ms) as well as the tumor volumes measured in angiographic CT were obtained and analyzed. The relationship of TNR-yp and TNR-ms was evaluated by Spearman's rank correlation and Wilcoxon's matched pairs test. In a total of 79 lesions of 52 patients, the distribution of microspheres was well demonstrated in both the SPECT and PET/CT images. A good correlation was observed of between TNR-ms and TNR-yp (rho value = 0.648, p < 0.001). The TNR-yp (median 2.78, interquartile range 2.43) tend to show significantly higher values than TNR-ms (median 2.49, interquartile range of 1.55) (p = 0.012). The TNR-yp showed weak correlation with tumor volume (rho = 0.230, p = 0.041). The 99mTc MAA SPECT showed a good correlation with {sup 90}Y PET/CT in TNR values, suggesting that {sup 99}mTc MAA can be used as an adequate pretreatment evaluation method. However, the {sup 99}mTc MAA SPECT image consistently shows lower TNR values compared to 90Y PET/CT, which means the possibility of underestimation of tumorous uptake in the partition dosimetry model using {sup 99}mTc MAA SPECT. Considering that

  18. Diffusion of hydrogen in yttrium

    International Nuclear Information System (INIS)

    Vorobyov, V.V.; Ryabchikov, L.N.

    1966-01-01

    In this work the diffusion coefficients of hydrogen in yttrium were determined from the rate at which the hydrogen was released from yttrium samples under a vacuum at temperatures of 450 to 850 0 C and from the quantity of hydrogen retained by yttrium at hydrogen pressures below 5 x 10 - 4 mm Hg in the same temperature range

  19. Carboxyl-Functionalized Polymeric Microspheres Prepared by One-Stage Photoinitiated RAFT Dispersion Polymerization

    Directory of Open Access Journals (Sweden)

    Jianbo Tan

    2017-12-01

    Full Text Available Herein, we report a photoinitiated reversible addition-fragmentation chain transfer (RAFT dispersion copolymerization of methyl methacrylate (MMA and methyl methacrylic (MAA for the preparation of highly monodisperse carboxyl-functionalized polymeric microspheres. High rates of polymerization were observed, with more than 90% particle yields being achieved within 3 h of UV irradiation. Effects of reaction parameters (e.g., MAA concentration, RAFT agent concentration, photoinitiator concentration, and solvent composition were studied in detail, and highly monodisperse polymeric microspheres were obtained in most cases. Finally, silver (Ag composite microspheres were prepared by in situ reduction of AgNO3 using the carboxyl-functionalized polymeric microspheres as the template. The obtained Ag composite microspheres were able to catalyze the reduction of methylene blue (MB with NaBH4 as a reductant.

  20. Structural and dielectric properties of yttrium substituted nickel ferrites

    International Nuclear Information System (INIS)

    Ognjanovic, Stevan M.; Tokic, Ivan; Cvejic, Zeljka; Rakic, Srdjan; Srdic, Vladimir V.

    2014-01-01

    Graphical abstract: - Highlights: • Dense NiFe 2−x Y x O 4 ceramics (with 0 ≤ x ≤ 0.3) were prepared. • Pure spinels were obtained for x ≤ 0.07 while for x ≥ 0.15 samples had secondary phases. • With addition of yttrium, ac conductivity slightly increased. • We suggest several effects that can explain the observed changes in ac conduction. • With addition of yttrium, dielectric constant increased while the tg δ decreased. - Abstract: The influence of Y 3+ ions on structural and dielectric properties of nickel ferrites (NiFe 2−x Y x O 4 , where 0 ≤ x ≤ 0.3) has been studied. The as-synthesized samples, prepared by the co-precipitation method, were analyzed by XRD and FTIR which suggested that Y 3+ ions were incorporated into the crystal lattice for all the samples. However, the XRD analysis of the sintered samples showed that secondary phases appear in the samples with x > 0.07. The samples have densities greater than 90% TD and the SEM images showed that the grain size decreases with the addition of yttrium. Dielectric properties measured from 150 to 25 °C in the frequency range of 100 Hz–1 MHz showed that the addition of yttrium slightly increases the ac conductivity and decreases the tg δ therefore making the materials better suited for the use in microwave devices

  1. Quantitative analysis of strontium 90 in the radioactive wastes by means of thenoyltrifluoroacetone; Dosage du strontium 90 dans les effluents radioactifs par le thenoyltrifluoroacetone

    Energy Technology Data Exchange (ETDEWEB)

    Testemale, G; Leredde, J L [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1970-07-01

    A simple method of analysing the quantity of {sup 90}Sr has been perfected. It consists in a double extraction of it by means of thenoyltrifluoroacetone and tributylphosphate in tetrachloride of carbon followed by eliminating yttrium 90 by means of thenoyltrifluoroacetone in the benzene. Numberings on aliquot parts of wastes make the determination of that element possible. The yield is about 97 per cent. (authors) [French] Une technique simple du dosage du {sup 90}Sr a ete mise au point. Elle consiste en une double extraction par le thenoyltrifluoroacetone et le tributylphosphate dans le tetrachlorure de carbone, suivie de l'elimination de l'yttrium 90 par le thenoyltrifluoroacetone dans le benzene, Des comptages sur des parties aliquotes d'effluents permettent la dermination de cet element. Rendement environ 97 pour cent. (auteurs)

  2. High temperature mechanical behaviour of glass-ceramics in the YSiAlON and ErSiAlON systems

    Energy Technology Data Exchange (ETDEWEB)

    Bondanini, A.; Massouras, G.; Besson, J.L. [ENSCI, Limoges (France). SPCTS

    2002-07-01

    The high temperature mechanical behaviour of oxynitride glass-ceramics in the YSiAlON and ErSiAlON systems was studied in the 950-1150 C temperature range under compressive stresses ranging from 20 to 100 MPa. The parent glass had a composition of 35 Y(or Er)-45 Si-20 Al-83 O-17 N in equivalent percent. Starting from these glasses, glass-ceramics were prepared using a two stage heat treatment: nucleation at the optimum nucleation temperature followed by crystal growth at 1050, 1150 or 1250 C. The two parent glasses had similar viscosities, with that of the Er-glass being slightly less than that of the Y-glass. After the devitrification treatment at 1050 C, B-phase (M{sub 2}SiAlO{sub 5}N) was the only crystalline phase formed in both systems. The creep behaviour was similar for the yttrium and the erbium materials. It was characterised by a long transient stage, due to the viscoelastic response of the residual glass, with recovered strain after unloading decreasing as loading time increased. The creep resistance was compared to that of the parent glasses in terms of apparent viscosity. The crystallisation of 75% of the glass resulted in an increase in viscosity such that a temperature some 100 C higher showed the same viscosity value. After heat treatment at 1150 C, the phase assemblage in the yttrium material changed with the formation of wollastonite and partial conversion of B-phase into Iw-phase. The apparent viscosity was 2 orders of magnitude higher than that of the samples heat treated at 1050 C and no strain recovery was observed upon unloading. In contrast, the erbium materials retained the same microstructure as after the heat treatment at 1050{sup b}C and there was no difference in the creep behaviour of the samples heat treated at 1050 or 1150 C. After a crystallisation treatment at 1250 C of the yttrium parent glass, the glass-ceramic consisted of yttrium aluminium garnet, N-apatite and {beta}-Y{sub 2}Si{sub 2}O{sub 7} and showed excellent creep

  3. Texture and deformation mechanism of yttrium

    International Nuclear Information System (INIS)

    Adamesku, R.A.; Grebenkin, S.V.; Stepanenko, A.V.

    1992-01-01

    X-ray pole figure analysis was applied to study texture and deformation mechanism in pure and commercial polycrystalline yttrium on cold working. It was found that in cast yttrium the texture manifected itself weakly enough both for pure and commercial metal. Analysis of the data obtained made it possible to assert that cold deformation of pure yttrium in the initial stage occurred mainly by slip the role of which decreased at strains higher than 36%. The texture of heavily deformed commercial yttrium contained two components, these were an 'ideal' basic orientation and an axial one with the angle of inclination about 20 deg. Twinning mechanism was revealed to be also possible in commercial yttrium

  4. Microradiographic microsphere manipulator

    International Nuclear Information System (INIS)

    Singleton, R.M.

    1980-01-01

    A method and apparatus are provided for radiographic characterization of small hollow spherical members (microspheres), constructed of either optically transparent or opaque materials. The apparatus involves a microsphere manipulator which holds a batch of microspheres between two parallel thin plastic films for contact microradiographic characterization or projection microradiography thereof. One plastic film is translated to relative to and parallel to the other to roll the microspheres through any desired angle to allow different views of the microspheres

  5. Radioembolization of Colorectal Liver Metastases: Indications, Technique, and Outcomes.

    Science.gov (United States)

    Boas, F Edward; Bodei, Lisa; Sofocleous, Constantinos T

    2017-09-01

    Liver metastases are a major cause of death from colorectal cancer. Intraarterial therapy options for colorectal liver metastases include chemoinfusion via a hepatic arterial pump or port, irinotecan-loaded drug-eluting beads, and radioembolization using 90 Y microspheres. Intraarterial therapy allows the delivery of a high dose of chemotherapy or radiation into liver tumors while minimizing the impact on liver parenchyma and avoiding systemic effects. Specificity in intraarterial therapy can be achieved both through preferential arterial flow to the tumor and through selective catheter positioning. In this review, we discuss indications, contraindications, preprocedure evaluation, activity prescription, follow-up, outcomes, and complications of radioembolization of colorectal liver metastases. Methods for preventing off-target embolization, increasing the specificity of microsphere delivery, and reducing the lung-shunt fraction are discussed. There are 2 types of 90 Y microspheres: resin and glass. Because glass microspheres have a higher activity per particle, they can deliver a particular radiation dose with fewer particles, likely reducing embolic effects. Glass microspheres thus may be more suitable when early stasis or reflux is a concern, in the setting of hepatocellular carcinoma with portal vein invasion, and for radiation segmentectomy. Because resin microspheres have a lower activity per particle, more particles are needed to deliver a particular radiation dose. Resin microspheres thus may be preferable for larger tumors and those with high arterial flow. In addition, resin microspheres have been approved by the U.S. Food and Drug Administration for colorectal liver metastases, whereas institutional review board approval is required before glass microspheres can be used under a compassionate-use or research protocol. Finally, radiation segmentectomy involves delivering a calculated lobar activity of 90 Y microspheres selectively to treat a tumor

  6. Phase I trial of yttrium-90-labeled anti-prostate-specific membrane antigen monoclonal antibody J591 for androgen-independent prostate cancer.

    Science.gov (United States)

    Milowsky, Matthew I; Nanus, David M; Kostakoglu, Lale; Vallabhajosula, Shankar; Goldsmith, Stanley J; Bander, Neil H

    2004-07-01

    To determine the maximum-tolerated dose (MTD), toxicity, human antihuman antibody (HAHA) response, pharmacokinetics, organ dosimetry, targeting, and preliminary efficacy of yttrium-90-labeled anti-prostate-specific membrane antigen monoclonal antibody J591 ((90)Y-J591) in patients with androgen-independent prostate cancer (PC). Patients with androgen-independent PC and evidence of disease progression received indium-111-J591 for pharmacokinetic and biodistribution determinations followed 1 week later by (90)Y-J591 at five dose levels: 5, 10, 15, 17.5, and 20 mCi/m(2). Patients were eligible for up to three re-treatments if platelet and neutrophil recovery was satisfactory. Twenty-nine patients with androgen-independent PC received (90)Y-J591, four of whom were re-treated. Dose limiting toxicity (DLT) was seen at 20 mCi/m(2), with two patients experiencing thrombocytopenia with non-life-threatening bleeding episodes requiring platelet transfusions. The 17.5-mCi/m(2) dose level was determined to be the MTD. No re-treated patients experienced DLT. Nonhematologic toxicity was not dose limiting. Targeting of known sites of bone and soft tissue metastases was seen in the majority of patients. No HAHA response was seen. Antitumor activity was seen, with two patients experiencing 85% and 70% declines in prostate-specific antigen (PSA) levels lasting 8 and 8.6 months, respectively, before returning to baseline. Both patients had objective measurable disease responses. An additional six patients (21%) experienced PSA stabilization. The recommended dose for (90)Y-J591 is 17.5 mCi/m(2). Acceptable toxicity, excellent targeting of known sites of PC metastases, and biologic activity in patients with androgen-independent PC warrant further investigation of (90)Y-J591 in the treatment of patients with PC.

  7. Enteric-coated epichlorohydrin crosslinked dextran microspheres for site-specific delivery to colon.

    Science.gov (United States)

    Rai, Gopal; Yadav, Awesh K; Jain, Narendra K; Agrawal, Govind P

    2015-01-01

    Enteric-coated epichlorohydrin crosslinked dextran microspheres containing 5-Fluorouracil (5-FU) for colon drug delivery was prepared by emulsification-crosslinking method. The formulation variables studied includes different molecular weights of dextran, volume of crosslinking agent, stirring speed, time and temperature. Dextran microspheres showed mean entrapment efficiencies ranging between 77 and 87% and mean particle size ranging between 10 and 25 µm. About 90% of drug was released from uncoated dextran microspheres within 8 h, suggesting the fast release and indicated the drug loaded in uncoated microspheres, released before they reached colon. Enteric coating (Eudragit-S-100 and Eudragit-L-100) of dextran microspheres was performed by oil-in-oil solvent evaporation method. The release study of 5-FU from coated dextran microspheres was complete retardation in simulated gastric fluid (pH 1.2) and once the coating layer of enteric polymer was dissolved at higher pH (7.4 and 6.8), a controlled release of the drug from the microspheres was observed. Further, the release of drug was found to be higher in the presence of dextranase and rat caecal contents, indicating the susceptibility of dextran microspheres to colonic enzymes. Organ distribution and pharmacokinetic study in albino rats was performed to establish the targeting potential of optimized formulation in the colon.

  8. Histamine-imprinted microspheres: Comparison between conventional and raft-mediated polymerization techniques

    International Nuclear Information System (INIS)

    Romano, Edwin F. Jr.; So, Regina C.; Holdsworth, Clovia I.

    2015-01-01

    Molecularly imprinted microspheres (MIM) were synthesized via conventional free radical polymerization (CTP) and RAFT-mediated controlled radical polymerization (CRP) method using histamine as the template molecule. Optimal polymerization conditions were achieved using 4%(w/w) monomer feed concentration with 80=90% EGDMA as crosslinker, and histamine: MAA ratio of 1:4 in acetonitrile at 60°C for 24 hours. The size of CTP-M90 and CTP-M80 imprinted microspheres are comparable with that of RAFT polymer CRP-M80 at 264.5 ±12 nm in the swollen (DLS-DMSO) and collapsed state (SEM). For the CTP method, the presence of the template allows for a bigger particle size compared to the non-imprinted counterpart (NIM). Further, controlled growth was observed for the CRP technique, where the size of the imprinted microsphere, CRP-M80, is comparable to CRP-N80. The binding studies of CTP and CRP microspheres toward histamine were studied at concentrations well below biding with buffer concentration of 25mM at pH7. Results showed that the binding isotherms were found to conform to the Freundlich model. Moreover, results revealed that the difference in binding capacity (N) between MIM and NIM imparted by the imprinting process is significantly higher in CTP-80 (26 μmol/g) than both CTP-90 and CRP-80 (9 μmol/g). Non-competitive and competitive binding assays with L-histidine, imidazole, and tryptamine using CTP-80 and CRP-80 were also carried out. MIMs were shown to exhibit binding preference towards the template. (author)

  9. The production of lithium oxide microspheres from the disintegration of a liquid jet

    International Nuclear Information System (INIS)

    Al-Ubaidi, M.R.; Anno, J.N.

    1989-01-01

    Microspheres of lithium hydroxide (LiOH) were produced from in-flight solidification of droplets formed by the disintegration of an acoustically driven, mechanically vibrated cylindrical liquid jet of molten LiOH. The molten material at 470 to 480 degrees C was fed through a 25-gauge (0.0267-cm bore diameter) nozzle, interiorly electroplated with silver, under ∼27.6-kPa (4-psig) pressure, and at a mechanical vibration frequency of 10 Hz. The resulting jet issued into a 5.5-cm-diam vertical glass drop tube entraining a 94.5 cm 3 /s (12 ft 3 /h) argon gas stream at 75 degrees C. The 100-cm-long drop tube was sufficient to allow the droplets of molten LiOH resulting from jet disintegration to solidify in-flight without catastrophic thermal shock, being then collected a solid microspheres. These LiOH microspheres were then vacuum processed to lithium oxide (Li 2 O). Preliminary experiments resulted in microspheres with diameters varying from 120 to 185 μm, but with evidence of impurity contamination occurring during the initial stages of the process

  10. The physical and chemical stability of suspensions of sustained-release diclofenac microspheres.

    Science.gov (United States)

    Lewis, L; Boni, R L; Adeyeye, C M

    1998-01-01

    The major challenge in liquid sustained-release oral suspensions is to minimize drug diffusion into the suspending medium and to retain the original properties of the microparticles during storage. Diclofenac wax microspheres prepared by the hydrophobic congealable disperse phase method were formulated as a sustained release suspension and stored at three different temperatures (25, 37 and 45 degrees C) for 3 months, to evaluate the physical and chemical stability of the suspended microspheres. Suspensions of microspheres stored at ambient temperatures were both physically and chemically stable, but at higher temperatures, up to 45 degrees C, there was a decrease in drug release due to scaling and melting on the microsphere surface as observed by scanning electron microscopy. However, on prolonged storage, up to 90 days, especially at 45 degrees C, temperature became a dominant factor causing an increase in drug release. The suspension of diclofenac microspheres was chemically stable for 3 months, while the plain drug suspension exhibited slight degradation.

  11. A sonochemical route for the encapsulation of drug in magnetic microspheres

    International Nuclear Information System (INIS)

    Wu Shixi; Jiang Wei; Zhang Xiaojuan; Sun Huan; Zhang Wenyao; Dai Junjun; Liu Li; Chen Xiaolong; Li Fengsheng

    2012-01-01

    This study focused on the preparation and characterization of magnetic targeted antibiotic microspheres (MTAMs). MTAMs were prepared by a sonochemical method in the presence of hydrophobic Fe 3 O 4 nanoparticles and tetracycline. The properties of MTAMs were characterized by transmission electron microscopy, Fourier-transform infrared spectrum, thermogravimetric analysis, vibration sample magnetometry, and bacteriostatic experiment. The results indicated that the superparamagnetic microspheres have ultrafine size (below 230 nm), high saturation magnetization (80.90 emu/g), high biocompatibility, biodegradability, controlled-release, and antibiotic effect. It has been proved that MTAMs can carry out the function of magnetic targeted drugs delivery system by putting together magnetic materials and antibiotics. The possible formation mechanism of MTAMs was also discussed. In summary, MTAMs had potential in medical imaging, drug targeting, and catalysis. - Highlights: → Microspheres carry out the function of magnetic targeted drugs delivery system. → Microspheres exhibit high saturation magnetization and antibiotic effect. → Microspheres have a potential application in the biomedical field. → The sonochemical method is well controlled for the synthesis.

  12. Flexible Microsphere-Embedded Film for Microsphere-Enhanced Raman Spectroscopy.

    Science.gov (United States)

    Xing, Cheng; Yan, Yinzhou; Feng, Chao; Xu, Jiayu; Dong, Peng; Guan, Wei; Zeng, Yong; Zhao, Yan; Jiang, Yijian

    2017-09-27

    Dielectric microspheres with extraordinary microscale optical properties, such as photonic nanojets, optical whispering-gallery modes (WGMs), and directional antennas, have drawn interest in many research fields. Microsphere-enhanced Raman spectroscopy (MERS) is an alternative approach for enhanced Raman detection by dielectric microstructures. Unfortunately, fabrication of microsphere monolayer arrays is the major challenge of MERS for practical applications on various specimen surfaces. Here we report a microsphere-embedded film (MF) by immersing a highly refractive microsphere monolayer array in the poly(dimethylsiloxane) (PDMS) film as a flexible MERS sensing platform for one- to three-dimensional (1D to 3D) specimen surfaces. The directional antennas and wave-guided whispering-gallery modes (WG-WGMs) contribute to the majority of Raman enhancement by the MFs. Moreover, the MF can be coupled with surface-enhanced Raman spectroscopy (SERS) to provide an extra >10-fold enhancement. The limit of detection is therefore improved for sensing of crystal violet (CV) and Sudan I molecules in aqueous solutions at concentrations down to 10 -7 M. A hybrid dual-layer microsphere enhancer, constructed by depositing a MF onto a microsphere monolayer array, is also demonstrated, wherein the WG-WGMs become dominant and boost the enhancement ratio >50-fold. The present work opens up new opportunities for design of cost-effective and flexible MERS sensing platforms as individual or associated techniques toward practical applications in ultrasensitive Raman detection.

  13. Synthesis of plastic scintillation microspheres: Evaluation of scintillators

    International Nuclear Information System (INIS)

    Santiago, L.M.; Bagán, H.; Tarancón, A.; Garcia, J.F.

    2013-01-01

    The use of plastic scintillation microspheres (PSm) appear to be an alternative to liquid scintillation for the quantification of alpha and beta emitters because it does not generate mixed wastes after the measurement (organic and radioactive). In addition to routine radionuclide determinations, PSm can be used for further applications, e.g. for usage in a continuous monitoring equipment, for measurements of samples with a high salt concentration and for an extractive scintillation support which permits the separation, pre-concentration and measurement of the radionuclides without additional steps of elution and sample preparation. However, only a few manufacturers provide PSm, and the low number of regular suppliers reduces its availability and restricts the compositions and sizes available. In this article, a synthesis method based on the extraction/evaporation methodology has been developed and successfully used for the synthesis of plastic scintillation microspheres. Seven different compositions of plastic scintillation microspheres have been synthesised; PSm1 with polystyrene, PSm2 with 2,5-Diphenyloxazol(PPO), PSm3 with p-terphenyl (pT), PSm4 with PPO and 1,4-bis(5-phenyloxazol-2-yl) (POPOP), PSm5 pT and (1,4-bis [2-methylstyryl] benzene) (Bis-MSB), PSm6 with PPO, POPOP and naphthalene and PSm7 with pT, Bis-MSB and naphthalene. The synthesised plastic scintillation microspheres have been characterised in terms of their morphology, detection capabilities and alpha/beta separation capacity. The microspheres had a median diameter of approximately 130 μm. Maximum detection efficiency values were obtained for the PSm4 composition as follows 1.18% for 3 H, 51.2% for 14 C, 180.6% for 90 Sr/ 90 Y and 76.7% for 241 Am. Values of the SQP(E) parameter were approximately 790 for PSm4 and PSm5. These values show that the synthesised PSm exhibit good scintillation properties and that the spectra are at channel numbers higher than in commercial PSm. Finally, the addition

  14. Dysprosium lithium borate glass mircrospheres for radiation synovectomy: The in vitro and in vivo performance evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Di; Yu Jing [Institute of Bioengineering and Information Technology Materials, Center for Advanced Materials and Nano-Biomedicine, Tongji University, Shanghai, 200092 (China); Huang Wenhai, E-mail: whhuang@tongji.edu.cn [Institute of Bioengineering and Information Technology Materials, Center for Advanced Materials and Nano-Biomedicine, Tongji University, Shanghai, 200092 (China); Zhou Nai; Wang Deping [Institute of Bioengineering and Information Technology Materials, Center for Advanced Materials and Nano-Biomedicine, Tongji University, Shanghai, 200092 (China); Yin Wei [Institute of Isotope Research, Sinitic Academy of Atomic Energy, Beijing 102413 (China); Chen Yaqing [The Sixth People' s Hospital, Shanghai 200233 (China)

    2010-08-30

    The radioactive dysprosium lithium borate glass (DyLB) microspheres with different glass compositions were prepared for radiation synovectomy. The biodegradability and biocompatibility of these DyLB microspheres were evaluated in vitro and in vivo. The DyLB microspheres studied in this work were partially biodegradable in a simulated body fluid (SBF), with the final weight loss of the microspheres in the range of 24.6% and 55.0% (wt.%) after 8 days of immersion. The ICP results revealed that the dissolution of lithium significantly decreased from 100% to 53.7% with increasing content of Dy{sub 2}O{sub 3} in the microspheres from 18% to 22% (wt.%, from S-1 to S-3). However, for all of the three samples, nearly all of the dysprosium (> 99.997%, wt.%) remained in the microspheres, in the form of insoluble phosphates and carbonates, which was proved by the SEM and EDX analyses. The degradation of DyLB microspheres in SBF gradually decreased with immersion time and eventually reached equilibrium after 7 days of immersion. Compared to the other two samples, the S-3 sample with the lowest Dy{sup 3+} dissolution (about 0.002%) was considered more secure for clinical application. Furthermore, the S-3 DyLB microspheres exhibited good biocompatibility, since neither tissue damage nor inflammation was observed, after they were implanted in the liver of rat for two weeks. After neutron activation, the radionuclide purity of radioactive S-3 DyLB microspheres was 99.999%, which were suitable for radiation synovectomy.

  15. Oxaliplatin loaded PLAGA microspheres: design of specific release profiles.

    Science.gov (United States)

    Lagarce, F; Cruaud, O; Deuschel, C; Bayssas, M; Griffon-Etienne, G; Benoit, J

    2002-08-21

    Oxaliplatin loaded PLAGA microspheres have been prepared by solvent extraction process. Parameters affecting the release kinetics in vitro have been studied in order to design specific release profiles suitable for direct intra-tumoral injection. By varying the nature and the relative proportions of different polymers we managed to prepare microspheres with good encapsulation efficiency (75-90%) and four different release profiles: zero order kinetics (type II) and the classical sigmoïd release profile with three different sizes of plateau and burst. These results, if correlated with in vivo activity, are promising to enhance effectiveness of local tumor treatment.

  16. Active self-healing encapsulation of vaccine antigens in PLGA microspheres

    Science.gov (United States)

    Desai, Kashappa-Goud H.; Schwendeman, Steven P.

    2013-01-01

    Herein, we describe the detailed development of a simple and effective method to microencapsulate vaccine antigens in poly(lactic-co-glycolic acid) (PLGA) by simple mixing of preformed active self-microencapsulating (SM) PLGA microspheres in a low concentration aqueous antigen solution at modest temperature (10-38 °C). Co-encapsulating protein-sorbing vaccine adjuvants and polymer plasticizers were used to “actively” load the protein in the polymer pores and facilitate polymer self-healing at temperature > hydrated polymer glass transition temperature, respectively. The microsphere formulation parameters and loading conditions to provide optimal active self-healing microencapsulation of vaccine antigen in PLGA was investigated. Active self-healing encapsulation of two vaccine antigens, ovalbumin and tetanus toxoid (TT), in PLGA microspheres was adjusted by preparing blank microspheres containing different vaccine adjuvant (aluminum hydroxide (Al(OH)3) or calcium phosphate). Active loading of vaccine antigen in Al(OH)3-PLGA microspheres was found to: a) increase proportionally with an increasing loading of Al(OH)3 (0.88-3 wt%) and addition of porosigen, b) decrease when the inner Al(OH)3/trehalose phase to 1 mL outer oil phase and size of microspheres was respectively > 0.2 mL and 63 μm, and c) change negligibly by PLGA concentration and initial incubation (loading) temperature. Encapsulation of protein sorbing Al(OH)3 in PLGA microspheres resulted in suppression of self-healing of PLGA pores, which was then overcome by improving polymer chain mobility, which in turn was accomplished by coincorporating hydrophobic plasticizers in PLGA. Active self-healing microencapsulation of manufacturing process-labile TT in PLGA was found to: a) obviate micronization- and organic solvent-induced TT degradation, b) improve antigen loading (1.4-1.8 wt% TT) and encapsulation efficiency (~ 97%), c) provide nearly homogeneous distribution and stabilization of antigen in polymer

  17. Lung Shunt Fraction prior to Yttrium-90 Radioembolization Predicts Survival in Patients with Neuroendocrine Liver Metastases: Single-Center Prospective Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, Johannes M. [Yale University, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging (United States); Ambinder, Emily McIntosh [John Hopkins University School of Medicine, Department of Diagnostic Radiology (United States); Ghodadra, Anish [University of Pittsburgh School of Medicine, Interventional Radiology, Department of Radiology (United States); Xing, Minzhi [Yale University, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging (United States); Prajapati, Hasmukh J. [The University of Tennessee Health Science Center, Division of Interventional Radiology, Department of Radiology (United States); Kim, Hyun S., E-mail: kevin.kim@yale.edu [Yale University, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging (United States)

    2016-07-15

    ObjectiveTo investigate survival outcomes following radioembolization with Yttrium-90 (Y90) for neuroendocrine tumor liver metastases (NETLMs). This study was designed to assess the efficacy of Y90 radioembolization and to evaluate lung shunt fraction (LSF) as a predictor for survival.MethodsA single-center, prospective study of 44 consecutive patients (median age: 58.5 years, 29.5 % male) diagnosed with pancreatic (52.3 %) or carcinoid (47.7 %) NETLMs from 2006 to 2012 who underwent Y90 radioembolization was performed. Patients’ baseline characteristics, including LSF and median overall survival (OS) from first Y90 radioembolization, were recorded and compared between patients with high (≥10 %) and low (<10 %) LSF. Baseline comparisons were performed using Fisher’s exact tests for categorical and Mann–Whitney U test for continuous variables. Survival was calculated using the Kaplan–Meier method. Univariate (Wilcoxon rank-sum test) and multivariate analyses (Cox Proportional Hazard Model) for risk factor analysis were performed.ResultsThere was no statistically significant difference in age, gender, race, tumor properties, or previous treatments between patients with high (n = 15) and low (n = 29) LSF. The median OS was 27.4 months (95 %CI 12.73–55.23), with 4.77 months (95 %CI 2.87–26.73) for high and 42.77 months (95 %CI 18.47–59.73) for low LSF (p = 0.003). Multivariate analysis identified high LSF (p = 0.001), total serum bilirubin >1.2 mg (p = 0.016), and lack of pretreatment with octreotide (p = 0.01) as independent prognostic factors for poorer survival. Tumor type and total radiation dose did not predict survival.ConclusionsLSF ≥10 %, elevated bilirubin levels, and lack of pretreatment with octreotide were found to be independent prognostic factors for poorer survival in patients with NETLMs.

  18. Simulation Model of Microsphere Distribution for Selective Internal Radiation Therapy Agrees With Observations

    Energy Technology Data Exchange (ETDEWEB)

    Högberg, Jonas, E-mail: jonas.hogberg@radfys.gu.se [Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Rizell, Magnus [Department of Surgery, Sahlgrenska University Hospital, Gothenburg (Sweden); Hultborn, Ragnar; Svensson, Johanna [Department of Oncology, Sahlgrenska University Hospital, Gothenburg (Sweden); Henrikson, Olof [Department of Radiology, Sahlgrenska University Hospital, Gothenburg (Sweden); Mölne, Johan [Department of Pathology, Sahlgrenska University Hospital, Gothenburg (Sweden); Gjertsson, Peter [Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg (Sweden); Bernhardt, Peter [Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg (Sweden)

    2016-10-01

    Purpose: To perform a detailed analysis of microsphere distribution in biopsy material from a patient treated with {sup 90}Y-labeled resin spheres and characterize microsphere distribution in the hepatic artery tree, and to construct a novel dichotomous bifurcation model for microsphere deposits and evaluate its accuracy in simulating the observed microsphere deposits. Methods and Materials: Our virtual model consisted of arteries that successively branched into 2 new generations of arteries at 20 nodes. The artery diameter exponentially decreased from the lowest generation to the highest generation. Three variable parameters were optimized to obtain concordance between simulations and measure microsphere distributions: an artery coefficient of variation (ACV) for the diameter of all artery generations and the microsphere flow distribution at the nodes; a hepatic tree distribution volume (HDV) for the artery tree; and an artery diameter reduction (ADR) parameter. The model was tested against previously measured activity concentrations in 84 biopsies from the liver of 1 patient. In 16 of 84 biopsies, the microsphere distribution regarding cluster size and localization in the artery tree was determined via light microscopy of 30-μm sections (mean concentration, 14 microspheres/mg; distributions divided into 3 groups with mean microsphere concentrations of 4.6, 14, and 28 microspheres/mg). Results: Single spheres and small clusters were observed in terminal arterioles, whereas large clusters, up to 450 microspheres, were observed in larger arterioles. For 14 microspheres/mg, the optimized parameter values were ACV=0.35, HDV = 50 cm{sup 3}, and ADR=6 μm. For 4.6 microspheres/mg, ACV and ADR decreased to 0.26 and 0 μm, respectively, whereas HDV increased to 130 cm{sup 3}. The opposite trend was observed for 28 microspheres/mg: ACV = 0.49, HDV = 20 cm{sup 3}, and ADR = 8 μm. Conclusion: Simulations and measurements reveal that microsphere clusters are

  19. Kinetics of yttrium dissolution from waste ceramic dust

    OpenAIRE

    STOPIC SRECKO R.; FRIEDRIH BERND G.

    2016-01-01

    Yttrium is a silvery transition metal and has similar chemical properties to lanthanoids. Because of this similarity, yttrium belongs to rare earth elements. Ytttrium and yttrium oxide are mostly used in fluoroscent lamps, production of electrodes, in electronic filters, lasers, superconductors and as additives in various materials to improve their properties. Yttrium is mainly recovered from the minerals monazite [(Ce,La,Th,Nd,Y)PO4] and xenotime YPO4.The presence of radioactive elements suc...

  20. Influence of radiant heating treatments on fusion of high-temperature superconducting yttrium ceramics

    International Nuclear Information System (INIS)

    Bitenbaev, M.I.; Polyakov, A.I.

    1999-01-01

    Regardless of the fact that the materials made of HTSC-ceramics are promising, there is no any information about their successful practical application in publications. To our opinion, it is explained by the fact, first of all, that the conservative technologies of the powder metallurgy do not allow producing HTSC systems with excellent operating performance (structure homogeneity, long-term stability of Sc properties and etc.). This report presents outcomes of experiments on fusion of yttrium ceramics containing raw components irradiated by g-rays 60 Co under the temperature exceeding 500 degrees C. HTSC properties of ceramics were studied according to their differential spectra of radio-frequency (RF) field absorption. The RF absorption spectrum of yttrium ceramics samples produced according to conservative technology is sufficiently permitted triplet with the Sc transition temperatures range of 80 K, 90 K, 95 K. Irradiation under the increased temperatures and mechanical limitation allow producing samples of yttrium HTSC-ceramics with sufficient homogeneous structure and superconducting properties that are stable to air conditions for not less than one year

  1. Effect of crosslinking agents on chitosan microspheres in controlled release of diclofenac sodium

    Directory of Open Access Journals (Sweden)

    Vanessa L. Gonçalves

    2005-03-01

    Full Text Available In this work chitosan microspheres were prepared by the simple coacervation method and crosslinked using epichlorhydrin or glutaraldehyde for the controlled release of diclofenac sodium. The effects of the crosslinking agents on chitosan microspheres over a 12-hour period were assessed with regard to swelling, hydrolysis, porosity, crosslinking, impregnation of diclofenac sodium (DS, and consequently to the release of DS in buffer solutions, simulating the gastrointestinal tract. The degree of swelling varied with the pH for glutaraldehyde chitosan microspheres (GCM and epichlorhydrin chitosan microspheres (ECM. Partial acid and basic hydrolysis affected the swelling behavior of the GCM matrix. Release kinetics of diclofenac sodium from these matrices were investigated at pH 1.2, 6.8 and 9.0, simulating the gastrointestinal tract conditions. The results indicated that the release mechanism deviated slightly from Fickian transport.

  2. Phase I/II 90Y-Zevalin (yttrium-90 ibritumomab tiuxetan, IDEC-Y2B8) radioimmunotherapy dosimetry results in relapsed or refractory non-Hodgkin's lymphoma

    International Nuclear Information System (INIS)

    Wiseman, G.A.; Dunn, W.L.; White, C.A.; Berlfein, J.R.; Ding, E.; Grillo-Lopez, A.J.; Stabin, M.; Erwin, W.; Spies, S.; Dahlbom, M.; Silverman, D.H.S.; Raubitschek, A.; Karvelis, K.; Schultheiss, T.; Witzig, T.E.; Belanger, R.

    2000-01-01

    Dosimetry studies in patients with non-Hodgkin's lymphoma were performed to estimate the radiation absorbed dose to normal organs and bone marrow from 90 Y-Zevalin (yttrium-90 ibritumomab tiuxetan, IDEC-Y2B8) treatment in this phase I/II, multicenter trial. The trial was designed to determine the dose of Rituximab (chimeric anti-CD20, Rituxan, IDEC-C2B8, MabThera), the unlabeled antibody given prior to the radioconjugate to clear peripheral blood B cells and optimize distribution, and to determine the maximum tolerated dose of 90 Y-Zevalin [7.4, 11, or 15 MBq/kg (0.2, 0.3, or 0.4 mCi/kg)]. Patients received 111 In-Zevalin (indium-111 ibritumomab tiuxetan, IDEC-In2B8) on day 0 followed by a therapeutic dose of 90 Y-Zevalin on day 7. Both doses were preceded by an infusion of the chimeric, unlabeled antibody Rituximab. Following administration of 111 In-Zevalin, serial anterior/posterior whole-body scans were acquired. Major-organ radioactivity versus time estimates were calculated using regions of interest. Residence times were computed and entered into the MIRDOSE3 computer software program to calculate estimated radiation absorbed dose to each organ. Initial analyses of estimated radiation absorbed dose were completed at the clinical site. An additional, centralized dosimetry analysis was performed subsequently to provide a consistent analysis of data collected from the seven clinical sites. In all patients with dosimetry data (n=56), normal organ and red marrow radiation absorbed doses were estimated to be well under the protocol-defined upper limit of 20 Gy and 3 Gy, respectively. Median estimated radiation absorbed dose was 3.4 Gy to liver (range 1.2-7.8 Gy), 2.6 Gy to lungs (range 0.72-4.4 Gy), and 0.38 Gy to kidneys (range 0.07-0.61 Gy). Median estimated tumor radiation absorbed dose was 17 Gy (range 5.8-67 Gy). No correlation was noted between hematologic toxicity and the following variables: red marrow radiation absorbed dose, blood T 1/2 , blood AUC

  3. Phase II trial of yttrium-90-DOTA-biotin pretargeted by NR-LU-10 antibody/streptavidin in patients with metastatic colon cancer

    International Nuclear Information System (INIS)

    Knox, S J.; Goris, M L.; Tempero, M.; Weiden, P L.; Gentner, L.; Breitz, H.; Adams, G. P.; Axworthy, D.; Gaffigan, S.; Bryan, K.; Fisher, Darrell R.; Colcher, D; Horak, I D.; Weiner, L M.

    1999-01-01

    A Phase II study of yttrium-90-tetra-azacyclododecanetetra-acetic acid-biotin (Y-90-DOTA-biotin) pretargeted by NR-LU-10 antibody/streptavidin (SA) was performed. The primary objectives of the study were to evaluate the efficacy and safety of this therapy in patients with metastatic colon cancer. Twenty-five patients were treated with a single dose of 110 mCi/m 2 (mean administered dose, 106.5-10.3 mCi/m 2 ) of Y-90-DOTA-biotin. There were three components of the therapy. Patients first received NR-LU-10/SA on day 1. A clearing agent (biotin-galactose-human serum albumin) was administered 48 h after the NR-LU-10/SA to remove residual circulating unbound NR-LU-10/SA. Lastly, 24 h after administration of clearing agent, patients received biotin-DOTA-labeled with 110 mCi/m 2 Y-90. All three components of the therapy were administered i.v. Both hematological and nonhematological toxicities were observed. Diarrhea was the most frequent grade 4 nonhematological toxicity (16%; with 16% grade 3 diarrhea). Hematological toxicity was less severe with 8% grade 3 and 8% grade 4 neutropenia and 8% grade 3 and 16% grade 4 thrombocytopenia. The overall response rate was 8%. Two partial responders had freedom from progression of 16 weeks. Four patients (16%) had stable disease with freedom from progression of 10-20 weeks. Despite the relatively disappointing results of this study in terms of therapeutic efficacy and toxicity, proof of principle was obtained for the pretargeting approach. In addition, valuable new information was obtained about normal tissue tolerance to low-dose-rate irradiation that will help to provide useful guidelines for future study designs

  4. Fluorescent probe encapsulated hydrogel microsphere for selective and reversible detection of Hg{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Song, Zhenhu; Wang, Fang; Qiang, Jian; Zhang, Zhijie; Chen, Yahui; Wang, Yong; Zhang, Wei; Chen, Xiaoqiang

    2017-03-15

    We developed a simple and sensitive hydrogel sensor in the form of microspheres by using fluorescence probe encapsulated within a hydrogel matrix for the detection of Hg{sup 2+}. The traditional fluorescence probes suspended in solution are not transportable and recoverable. To overcome these disadvantages, we devised poly(ethylene glycol) diacrylate-based hydrogel microspheres in which fluorescence probe (R19S) was embedded at high density. The functionalized hydrogel microspheres were prepared by combining a microfluidic device with UV light. The hydrogel microspheres-based sensor exhibited good selectivity to Hg{sup 2+} among various metal ions and high sensitivity with a detection limit of 90 nM. Furthermore, after binding with Hg{sup 2+}, the R19S encapsulated hydrogel microspheres can be separated from testing samples easily and treated with the solution containing KI to remove Hg{sup 2+} and realize reusable detection. The current work may offer a new method for Hg{sup 2+} recognition with a more efficient manner.

  5. Formation mechanism of a silane-PVA/PVAc complex film on a glass fiber surface.

    Science.gov (United States)

    Repovsky, Daniel; Jane, Eduard; Palszegi, Tibor; Slobodnik, Marek; Velic, Dusan

    2013-10-21

    Mechanical properties of glass fiber reinforced composite materials are affected by fiber sizing. A complex film formation, based on a silane film and PVA/PVAc (polyvinyl alcohol/polyvinyl acetate) microspheres on a glass fiber surface is determined at 1) the nanoscale by using atomic force microscopy (AFM), and 2) the macroscale by using the zeta potential. Silane groups strongly bind through the Si-O-Si bond to the glass surface, which provides the attachment mechanism as a coupling agent. The silane groups form islands, a homogeneous film, as well as empty sites. The average roughness of the silanized surface is 6.5 nm, whereas it is only 0.6 nm for the non-silanized surface. The silane film vertically penetrates in a honeycomb fashion from the glass surface through the deposited PVA/PVAc microspheres to form a hexagonal close pack structure. The silane film not only penetrates, but also deforms the PVA/PVAc microspheres from the spherical shape in a dispersion to a ellipsoidal shape on the surface with average dimensions of 300/600 nm. The surface area value Sa represents an area of PVA/PVAc microspheres that are not affected by the silane penetration. The areas are found to be 0.2, 0.08, and 0.03 μm(2) if the ellipsoid sizes are 320/570, 300/610, and 270/620 nm for silane concentrations of 0, 3.8, and 7.2 μg mL(-1), respectively. The silane film also moves PVA/PVAc microspheres in the process of complex film formation, from the low silane concentration areas to the complex film area providing enough silane groups to stabilize the structure. The values for the residual silane honeycomb structure heights (Ha ) are 6.5, 7, and 12 nm for silane concentrations of 3.8, 7.2, and 14.3 μg mL(-1), respectively. The pH-dependent zeta-potential results suggest a specific role of the silane groups with effects on the glass fiber surface and also on the PVA/PVAc microspheres. The non-silanized glass fiber surface and the silane film have similar zeta potentials ranging

  6. Interaction of oxygen vacancies in yttrium germanates

    KAUST Repository

    Wang, Hao

    2012-01-01

    Forming a good Ge/dielectric interface is important to improve the electron mobility of a Ge metal oxide semiconductor field-effect transistor. A thin yttrium germanate capping layer can improve the properties of the Ge/GeO 2 system. We employ electronic structure calculations to investigate the effect of oxygen vacancies in yttrium-doped GeO 2 and the yttrium germanates Y 2Ge 2O 7 and Y 2GeO 5. The calculated densities of states indicate that dangling bonds from oxygen vacancies introduce in-gap states, but the system remains insulating. However, yttrium-doped GeO 2 becomes metallic under oxygen deficiency. Y-doped GeO 2, Y 2Ge 2O 7 and Y 2GeO 5 are calculated to be oxygen substoichiometric under low Fermi energy conditions. The use of yttrium germanates is proposed as a way to effectively passivate the Ge/dielectric interface. This journal is © 2012 the Owner Societies.

  7. Preparation and evaluation of microspheres of xyloglucan and its thiolated xyloglucan derivative.

    Science.gov (United States)

    Sonawane, Savita; Bhalekar, Mangesh; Shimpi, Shamkant

    2014-08-01

    Xyloglucan is a natural polymer reported to possess mucoadhesive properties. To enhance the mucoadhesion potential, xyloglucan was thiolated with cysteine. The microspheres of xyloglucan were prepared using a biocompatible crosslinker sodium trimetaphosphate and it was optimized for formulation variables, namely polymer concentration, internal:external phase ratio and stirring speed using a Box-Behnken experimental design. The formulation was also optimized for performance parameters like entrapment, t80 and % mucoadhesion. The microspheres were characterized by Fourier transform infrared spectroscopy, DSC and SEM for the optimum formula and then were reproduced by replacing the xyloglucan with thiomer. The microspheres formed showed entrapment efficiency of about 80%, t80 of about 400min and % mucoadhesion of 60% while same for thiomer were 90%, 500min and 80% respectively. In oral glucose tolerance test protocol the thiomer microspheres showed significant reduction in blood glucose levels. Thus thiolated xyloglucan offers a better polymer for multiparticulate drug delivery. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Modelling and Characterization of Effective Thermal Conductivity of Single Hollow Glass Microsphere and Its Powder.

    Science.gov (United States)

    Liu, Bing; Wang, Hui; Qin, Qing-Hua

    2018-01-14

    Tiny hollow glass microsphere (HGM) can be applied for designing new light-weighted and thermal-insulated composites as high strength core, owing to its hollow structure. However, little work has been found for studying its own overall thermal conductivity independent of any matrix, which generally cannot be measured or evaluated directly. In this study, the overall thermal conductivity of HGM is investigated experimentally and numerically. The experimental investigation of thermal conductivity of HGM powder is performed by the transient plane source (TPS) technique to provide a reference to numerical results, which are obtained by a developed three-dimensional two-step hierarchical computational method. In the present method, three heterogeneous HGM stacking elements representing different distributions of HGMs in the powder are assumed. Each stacking element and its equivalent homogeneous solid counterpart are, respectively, embedded into a fictitious matrix material as fillers to form two equivalent composite systems at different levels, and then the overall thermal conductivity of each stacking element can be numerically determined through the equivalence of the two systems. The comparison of experimental and computational results indicates the present computational modeling can be used for effectively predicting the overall thermal conductivity of single HGM and its powder in a flexible way. Besides, it is necessary to note that the influence of thermal interfacial resistance cannot be removed from the experimental results in the TPS measurement.

  9. Production and Characterization of Glass Microspheres for Hepatic Cancer Treatment

    OpenAIRE

    Bortot, M. B.; Prastalo, S.; Prado, Miguel Oscar

    2017-01-01

    A simple theoretical mathematical model was developed to assess the process of glass particles spheroidization in a propane-butane-oxygen flame. The model has been designed to gain a better understanding of the dependency amongst the variables that come into play during glass spheroidization. Using the model and theoretical values of: glass viscosity, density, shear modulus, thermal conductivity as well as measured values of the temperature of the flame at different positions, particle size a...

  10. Comparison of gas clearance and radioactive microspheres for pancreatic blood flow measurement

    International Nuclear Information System (INIS)

    DeMar, A.R.; Graham, L.S.; Lake, R.; Fink, A.S.

    1989-01-01

    Measurement of pancreatic blood flow (PBF) is technically demanding. Although radiolabeled microspheres are considered the gold standard for PBF assessment, they have practical limitations. In the current study, H 2 and xenon-133 gas clearance techniques were adapted to PBF measurement and compared to radiolabeled microsphere techniques. Simultaneous measurements of PBF were made using either hydrogen or xenon gas washout and radiolabeled microspheres. Measurements were made under basal, vasoconstricted (vasopressin 2U i.v. or nicotine 4 micrograms/kg/h) and stimulated (secretin 125 ng/kg/h or 2 U/kg i.v.) conditions (random order). Mean PBF was 26.9 +/- 5.3, 50.5 +/- 2.3 and 27.6 +/- 5.2 ml/min/100 g basally, 36.9 +/- 8.0, 90.1 +/- 18.9, and 81.7 +/- 14.5 ml/min/100 g in the stimulated state, and 24.2 +/- 7.8, 25.0 +/- 3.5, and 14.9 +/- 7.5 ml/min/100 g in the vasoconstricted state for hydrogen gas clearance, xenon gas clearance, and radiolabeled microspheres, respectively. The H 2 clearance technique resulted in tissue trauma, was complicated by frequent electrode displacement, and correlated poorly (r2 = 0.36, p greater than 0.05) with microsphere values. In contrast, xenon clearance measurement had no apparent effect on the pancreas and correlated well (r2 = 0.83, p less than 0.01) with microsphere data. We conclude that xenon clearance offers an attractive, validated alternative to radiolabeled microspheres for measuring pancreatic blood flow

  11. Comparison of the Adverse Event Profile of TheraSphere® with SIR-Spheres® for the Treatment of Unresectable Hepatocellular Carcinoma: A Systematic Review.

    Science.gov (United States)

    Kallini, Joseph Ralph; Gabr, Ahmed; Thorlund, Kristian; Balijepalli, Chakrapani; Ayres, Dieter; Kanters, Steve; Ebrahim, Shanil; Mills, Edward; Lewandowski, Robert J; Salem, Riad

    2017-07-01

    To compare the safety profiles of TheraSphere ® (glass) and SIR-Spheres ® (resin) Y90 microspheres for the treatment of hepatocellular carcinoma. A systematic review was conducted using the databases MEDLINE, Embase, and Cochrane Trials Register to identify all relevant studies. Baseline characteristics and adverse events of all grades related to gastrointestinal, hepatobiliary, and respiratory systems were collected along with commonly reported outcomes related to post-embolization syndrome. For all outcomes, data from each study were tabulated for each intervention. Adverse events and patients were summed across studies on TheraSphere ® and SIR-Spheres ® , respectively, and the resulting proportion of patients experiencing an outcome for both interventions was calculated. Thirty-one observational studies were included in the review. In the adverse events of all grades, more patients treated with resin microspheres reported gastric ulcers, hepatic encephalopathy, cholecystitis, hepatic failure, and pleural effusion. Patients treated with resin microspheres also had more hepatobiliary adverse events of grade 3 or higher. In the events related to post-embolization syndrome, glass microspheres exhibited a similar safety profile compared to resin microspheres. Ascites and nausea grade 3 or higher were recorded more frequently with glass microsphere treatment. Based on this review of the published literature, glass microspheres exhibit a safety profile with fewer gastrointestinal and pulmonary adverse events compared to resin microspheres in the treatment of hepatocellular carcinoma.

  12. Comparison of the stability of Y-90-, Lu-177- and Ga-68- labeled human serum albumin microspheres (DOTA-HSAM)

    Energy Technology Data Exchange (ETDEWEB)

    Wunderlich, Gerd [Department of Nuclear Medicine, University Hospital, 01307 Dresden (Germany); Schiller, Eik, E-mail: eisc@rotop-pharmaka.d [ROTOP Pharmaka AG, 01454 Radeberg (Germany); Bergmann, Ralf; Pietzsch, Hans-Juergen [Forschungszentrum Dresden-Rossendorf, Institute of Radiopharmacy, P.O. Box 510119, 01314 Dresden (Germany)

    2010-11-15

    Introduction: Microparticles derived from denatured human serum albumin (DOTA-derivatized human serum albumin microspheres, or DOTA-HSAM) are attractive carriers of radionuclides for both therapeutic and diagnostic purposes. In this article, we describe a labeling procedure for diagnostic (Ga-68) and therapeutic (Y-90, Lu-177) radionuclides and report on the results of stability studies of these products. Methods: DOTA-HSAM was labeled in 0.5 M ammonium acetate buffer, pH 5.0, containing 0.02 mg/ml detergent. After adding the radionuclide, the mixture was shaken for 15 min at 90{sup o}C. Labeling yields and in vitro stability were determined by thin-layer chromatography. For determination of the in vivo stability of Ga-68 and Y-90 DOTA-HSAM, the particles were injected intravenously in Wistar rats. Results: Labeling yields up to 95% in the case of Ga-68 and Lu-177 were achieved. Ga-68-labeled DOTA-HSAM showed high in vitro and in vivo stability. The amount of particle-bound radioactivity of Lu-177 DOTA-HSAM declines slowly in a linear manner to approximately 72% after 13 days. For Y-90, the labeling yield decreased with increasing radioactivity level. We presume radiolysis as the reason for these findings. Conclusion: The labeling of DOTA-HSAM with different radionuclides is easy to perform. The radiation-induced cleavage of the labeled chelator together with the rather short half-life of radioactivity fixation in vivo (3.7 days) is, in our opinion, opposed to therapeutic applications of DOTA-HSAM. On the other hand, the high stability of Ga-68 DOTA-HSAM makes them an attractive candidate for the measurement of regional perfusion by PET.

  13. Comparison of the stability of Y-90-, Lu-177- and Ga-68- labeled human serum albumin microspheres (DOTA-HSAM)

    International Nuclear Information System (INIS)

    Wunderlich, Gerd; Schiller, Eik; Bergmann, Ralf; Pietzsch, Hans-Juergen

    2010-01-01

    Introduction: Microparticles derived from denatured human serum albumin (DOTA-derivatized human serum albumin microspheres, or DOTA-HSAM) are attractive carriers of radionuclides for both therapeutic and diagnostic purposes. In this article, we describe a labeling procedure for diagnostic (Ga-68) and therapeutic (Y-90, Lu-177) radionuclides and report on the results of stability studies of these products. Methods: DOTA-HSAM was labeled in 0.5 M ammonium acetate buffer, pH 5.0, containing 0.02 mg/ml detergent. After adding the radionuclide, the mixture was shaken for 15 min at 90 o C. Labeling yields and in vitro stability were determined by thin-layer chromatography. For determination of the in vivo stability of Ga-68 and Y-90 DOTA-HSAM, the particles were injected intravenously in Wistar rats. Results: Labeling yields up to 95% in the case of Ga-68 and Lu-177 were achieved. Ga-68-labeled DOTA-HSAM showed high in vitro and in vivo stability. The amount of particle-bound radioactivity of Lu-177 DOTA-HSAM declines slowly in a linear manner to approximately 72% after 13 days. For Y-90, the labeling yield decreased with increasing radioactivity level. We presume radiolysis as the reason for these findings. Conclusion: The labeling of DOTA-HSAM with different radionuclides is easy to perform. The radiation-induced cleavage of the labeled chelator together with the rather short half-life of radioactivity fixation in vivo (3.7 days) is, in our opinion, opposed to therapeutic applications of DOTA-HSAM. On the other hand, the high stability of Ga-68 DOTA-HSAM makes them an attractive candidate for the measurement of regional perfusion by PET.

  14. BMP2-loaded hollow hydroxyapatite microspheres exhibit enhanced osteoinduction and osteogenicity in large bone defects.

    Science.gov (United States)

    Xiong, Long; Zeng, Jianhua; Yao, Aihua; Tu, Qiquan; Li, Jingtang; Yan, Liang; Tang, Zhiming

    2015-01-01

    The regeneration of large bone defects is an osteoinductive, osteoconductive, and osteogenic process that often requires a bone graft for support. Limitations associated with naturally autogenic or allogenic bone grafts have demonstrated the need for synthetic substitutes. The present study investigates the feasibility of using novel hollow hydroxyapatite microspheres as an osteoconductive matrix and a carrier for controlled local delivery of bone morphogenetic protein 2 (BMP2), a potent osteogenic inducer of bone regeneration. Hollow hydroxyapatite microspheres (100±25 μm) with a core (60±18 μm) and a mesoporous shell (180±42 m(2)/g surface area) were prepared by a glass conversion technique and loaded with recombinant human BMP2 (1 μg/mg). There was a gentle burst release of BMP2 from microspheres into the surrounding phosphate-buffered saline in vitro within the initial 48 hours, and continued at a low rate for over 40 days. In comparison with hollow hydroxyapatite microspheres without BMP2 or soluble BMP2 without a carrier, BMP2-loaded hollow hydroxyapatite microspheres had a significantly enhanced capacity to reconstitute radial bone defects in rabbit, as shown by increased serum alkaline phosphatase; quick and complete new bone formation within 12 weeks; and great biomechanical flexural strength. These results indicate that BMP2-loaded hollow hydroxyapatite microspheres could be a potential new option for bone graft substitutes in bone regeneration.

  15. Photonic nanojet super-resolution in immersed ordered assembly of dielectric microspheres

    International Nuclear Information System (INIS)

    Geints, Y.E.; Zemlyanov, A.A.

    2017-01-01

    Highlights: • Ordered microassemblies of dielectric microspheres immersed in a transparent matrix exposed to a light wave produce an array of the “photonic nanojets” coupled through the field interference. • “Photonic nanojet” parameters depend on the inter-sphere gap and immersion depth. • Sphere microassembly can produce the jets with the sub-diffraction spatial resolution if the particles are loosely packed and semi-immersed. - Abstract: Specific spatially-localized optical field structure, which is often referred to as a photonic nanojet (PNJ), is formed in the near-field scattering area of non-absorbing dielectric micron-sized particle exposed to an optical radiation. By virtue of the finite-difference time-domain technique we numerically simulate the two-dimensional array of PNJs created by an ordered single-layer microassembly of glass microspheres immersed in a transparent polymer matrix. The behavior of the main PNJ parameters (length, diameter, and intensity) is analyzed subject to the immersion depth of the microparticles and cooperative interference effects of the neighboring microspheres. We show that depending on microassembly configuration, the PNJ quality can be significantly improved; in particular, the PNJ spatial resolution better than λ/5 can be achieved.

  16. Development of 90Sr/90Y Generator Systems Based on SLM Techniques for Radiolabelling of Therapeutic Biomolecules with 90Y. Chapter 14

    International Nuclear Information System (INIS)

    Thu, N.T.; Van Dong, D.; Van Cuong, B.; Van Khoa, C.; Cam Hoa, V.T.

    2015-01-01

    Yttrium-90 is one of the most useful radionuclides for radioimmunotherapeutic applications, especially for labelling peptides and antibodies. Studies were carried out to develop a 90 Sr/ 90 Y generator system based on the SLM technique. Two stages of 90 Sr/ 90 Y generator systems were developed at different activity levels of 5, 20, 50 and 100 mCi and operated with semiautomation in sequential mode. In the first stage of the system, PC88A based SLM was used, which transported 90 Y from a nitric acid medium containing 0.01–4M HNO 3 . In the second stage, the 90 Y from the first stage was transferred to the first compartment of the second stage using carbamoylmethyl phosphine oxide (CMPO) based SLM where 1M acetic acid was used as the receiving phase for 90 Y. Quality control was carried out for the products of 90 Y using EPC with paper chromatography and Tec control chromatography. Peptides and antibodies were labelled using the 90 Y product obtained from the generator developed in house. (author)

  17. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    Energy Technology Data Exchange (ETDEWEB)

    Burgmans, M.C., E-mail: mburgmans@hotmail.com [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Too, C.W., E-mail: too.chow.wei@singhealth.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Kao, Y.H., E-mail: yung.h.kao@gmail.com [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Goh, A.S.W., E-mail: anthony.goh.s.w@sgh.com.sg [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Chow, P.K.H., E-mail: gsupc@singnet.com.sg [Department of General Surgery, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Office of Clinical Sciences, Duke-NUS Graduate Medical School Singapore, 8 College Road, Singapore 169857 (Singapore); Department of Surgical Oncology, National Cancer Center Singapore, 11 Hospital Drive, Singapore 169610 (Singapore); Tan, B.S., E-mail: tan.bien.soo@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Tay, K.H., E-mail: tay.kiang.hiong@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Lo, R.H.G., E-mail: richard.lo.h.g@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)

    2012-12-15

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  18. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    International Nuclear Information System (INIS)

    Burgmans, M.C.; Too, C.W.; Kao, Y.H.; Goh, A.S.W.; Chow, P.K.H.; Tan, B.S.; Tay, K.H.; Lo, R.H.G.

    2012-01-01

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  19. Scandium, yttrium and the lanthanides

    International Nuclear Information System (INIS)

    Hart, F.A.

    1987-01-01

    This chapter on the chemistry of the coordination complexes of scandium, yttrium and the lanthanides includes sections on the nitrogen and oxygen donor ligands and complex halides of scandium, and the phosphorus and sulfur donor ligands of yttrium and the lanthanides. Complexes with the macrocylic ligands and with halides are also discussed. Sections on the NMR and electronic spectra of the lanthanides are also included. (UK)

  20. 90Sr content in 90Y-labeled SIR-spheres and Zevalin.

    Science.gov (United States)

    Metyko, John; Erwin, William; Poston, John; Jimenez, Sandra

    2014-11-01

    Three different 90Y internally administered radionuclide therapies are currently used in both standard-of-care and clinical trial procedures atMD Anderson Cancer Center. TheraSphere and SIR-Spheres therapies utilize 90Y-labeled microspheres, while Zevalin is an 90Y-labeled radioimmunotherapeutic agent. Several publications have indicated radionuclidic impurities resulting from 90Y production methods. The 90Y in SIR-Spheres and Zevalin are produced from a 90Sr/90Y generator, which leaves measurable quantities of 90Sr in the final product. TheraSphere 90Y is produced in a nuclear reactor which results in a large number of impurities, most notably 88Y and 91Y. Product information sheets reference these impurities with specific limits given. These limits represent a tiny fraction of the total product activity, and in the case of TheraSphere and SIR-Spheres gamma-emitting impurities, this has been verified in the literature. An analysis of 90Sr impurities in SIR-Spheres and Zevalin is presented in this paper. Impurity quantities were found to be within the vendors’ documented limits.

  1. Equilibrium Studies on the Extraction of Yttrium from Chloride Medium by Mono (2-Ethylhexyl) 2-Ethylhexyl Phosphonic Acid (Ion quest 801)

    International Nuclear Information System (INIS)

    Zaki, E.E.; Ismail, Z.H.; Aly, H.F.; Sabet, S.A.

    2008-01-01

    Since 90 Y is one of the useful radioisotopes in nuclear medicine, liquid-liquid extraction of yttrium from chloride medium has been studied under various conditions using neutralized and un-neutralized mono (2-ethylhexyl) 2-ethylhexyl phosphonic acid (EHEHPA) as an extractant. Effect of reagent concentration, ph of the aqueous medium, metal ion concentration and nature of the diluent on the extraction process has been carried out. Effect of temperature was studied and thermodynamic parameters were evaluated. Yttrium extracted in organic phase was stripped with various reagents. The stoichiometry of the extracted species of yttrium was determined on the basis of slope analysis of experimental results. Equilibrium equations of the extraction process have been estimated and verified

  2. [(90)Yttrium-DOTA]-TOC response is associated with survival benefit in iodine-refractory thyroid cancer: long-term results of a phase 2 clinical trial.

    Science.gov (United States)

    Iten, Fabienne; Muller, Beat; Schindler, Christian; Rasch, Helmut; Rochlitz, Christoph; Oertli, Daniel; Maecke, Helmut R; Muller-Brand, Jan; Walter, Martin A

    2009-05-15

    The authors aimed to explore the efficacy of (90)Yttrium-1,4,7,10-tetra-azacyclododecane N,N',N'',N'''-tetraacetic acid [(90)Y-DOTA]-Tyr(3)-octreotide (TOC) in advanced iodine-refractory thyroid cancer. In a phase 2 trial, the authors investigated biochemical response (assessed by serum thyroglobulin levels), survival, and the long-term safety profile of systemic [(90)Y-DOTA]-TOC treatment in metastasized iodine-refractory thyroid cancer. Adverse events were assessed according to the National Cancer Institute criteria. Survival analyses were performed by using multiple regression models. A total of 24 patients were enrolled. A median cumulative activity of 13.0 GBq (range, 1.7-30.3 GBq) was administered. Response was found in 7 (29.2%) patients. Eight (33.3%) patients developed hematologic toxicity grade 1-3, and 4 (16.7%) patients developed renal toxicity grade 1-4. The median survival was 33.4 months (range, 3.6-126.8 months) from time of diagnosis and 16.8 months (range, 1.8-99.1 months) from time of first [(90)Y-DOTA]-TOC treatment. Response to treatment was associated with longer survival from time of diagnosis (hazard ratio [HR], 0.17; 95% confidence interval [CI], 0.03-0.92; P = .04) and from time of first [(90)Y-DOTA]-TOC therapy (HR, 0.20; 95% CI, 0.04-0.94; P = .04). The visual grade of scintigraphic tumor uptake was not associated with treatment response (odds ratio [OR], 0.98; 95% CI, 0.26-3.14; P = 1.00). Response to [(90)Y-DOTA]-TOC in metastasized iodine-refractory thyroid cancer was associated with longer survival. Upcoming trials should aim to increase the number of treatment cycles.

  3. Titanium phosphate glass microcarriers induce enhanced osteogenic cell proliferation and human mesenchymal stem cell protein expression

    Directory of Open Access Journals (Sweden)

    Nilay J Lakhkar

    2015-11-01

    Full Text Available In this study, we have developed 50- to 100-µm-sized titanium phosphate glass microcarriers (denoted as Ti5 that show enhanced proliferation of human mesenchymal stem cells and MG63 osteosarcoma cells, as well as enhanced human mesenchymal stem cell expression of bone differentiation markers, in comparison with commercially available glass microspheres at all time points. We also demonstrate that these microcarriers provide superior human mesenchymal stem cell proliferation with conventional Dulbecco’s Modified Eagle medium than with a specially developed commercial stem cell medium. The microcarrier proliferative capacity is revealed by a 24-fold increase in MG63 cell numbers in spinner flask bioreactor studies performed over a 7-day period, versus only a 6-fold increase in control microspheres under the same conditions; the corresponding values of Ti5 and control microspheres under static culture are 8-fold and 7-fold, respectively. The capability of guided osteogenic differentiation is confirmed by ELISAs for bone morphogenetic protein-2 and osteopontin, which reveal significantly greater expression of these markers, especially osteopontin, by human mesenchymal stem cells on the Ti5 microspheres than on the control. Scanning electron microscopy and confocal laser scanning microscopy images reveal favorable MG63 and human mesenchymal stem cell adhesion on the Ti5 microsphere surfaces. Thus, the results demonstrate the suitability of the developed microspheres for use as microcarriers in bone tissue engineering applications.

  4. Features of solid solutions composition in magnesium with yttrium alloys

    International Nuclear Information System (INIS)

    Drits, M.E.; Rokhlin, L.L.; Tarytina, I.E.

    1983-01-01

    Additional data on features of yttrium solid solutions composition in magnesium in the course of their decomposition investigation in the case of aging are obtianed. The investigation has been carried out on the base of a binary magnesium-yttrium alloy the composition of which has been close to maximum solubility (at eutectic temperature) and magnesium-yttrium alloys additionally doped with zinc. It is shown that higher yttrium solubility in solid magnesium than it has been expected, issueing from the difference in atomic radii of these metals indicates electron yttrium-magnesium atoms interaction. In oversaturated magnesium-yttrium solid solutions at earlier decomposition stages Mg 3 Cd type ordering is observed. At aging temperatures up to 250 deg C and long exposures corresponding to highest strengthening in oversaturated magnesium yttrium solid solutions a rhombic crystal lattice phase with three symmetric orientations is formed

  5. [Synthesis of hollow titania microspheres by using microfluidic droplet-template].

    Science.gov (United States)

    Ma, Jingyun; Jiang, Lei; Qin, Jianhu

    2011-09-01

    Droplet-based microfluidics is of great interest due to its particular characteristics compared with the conventional methods, such as reduced reagent consumption, rapid mixing, high-throughput, shape controlled, etc. A novel method using microfluidic droplet as soft template for the synthesis of hollow titania microspheres was developed. A typical polydimethylsiloxane (PDMS) microfluidic device containing "flow-focusing" geometry was used to generate water/oil (W/O) droplet. The mechanism for the hollow structure formation was based on the interfacial hydrolysis reaction between the continuous phase containing titanium butoxide precursor and the dispersed containing water. The continuous phase mixed with butanol was added in the downstream of the channel after the hydrolysis reaction. This step was used for drawing the water out of the microgels for further hydrolysis. The microgels obtained through a glass pipe integrated were washed, dried under vacuum and calcined after aging for a certain time. The fluorescence and scanning electron microscope (SEM) image of the microspheres indicated the hollow structure and the thickness of the shell. In addition, these microspheres with thin shell (about 2 microm) were apt to rupture and collapse. Droplet-based microfluidic offered a gentle and size-controllable manner to moderate this problem. Moreover, it has potential applications in photocatalysis combined with some modification realized on the chip simultaneously.

  6. Extraction of nitrates of lanthanoids (3) of the yttrium group and yttrium (3) by trialkylbenzylammonium nitrate in toluene

    International Nuclear Information System (INIS)

    Pyartman, A.K.; Kovalev, S.V.; Keskinov, V.A.; Kopyrin, A.A.

    1997-01-01

    A study was made on extraction of nitrates of lanthanoids (3) of the yttrium group (terbium-lutetium) and yttrium (3) by trialkylbensylammonium nitrate in toluene at T=298.15 K pH 2. Extraction isotherms are described with account of formation of compound of (R 4 N) 2 [Ln(NO 3 ) 5 ] composition in organic phase. Values of extraction constants decreasing in terbium (3)-lutetium (3) series, were calculated. Value of extraction constant for yttrium (3) is close to the value of extraction constant for ytterbium (3). 13 refs., 2 figs., 3 tabs

  7. Development of 90Sr-90Y generators

    International Nuclear Information System (INIS)

    Barrio, Graciela

    2007-01-01

    Yttrium-90 is a radioisotope of great interest in the field of Nuclear Medicine. It is considered one of the most important and most used radionuclides for radioimmunotherapeutical applications, especially promising for the treatment of certain types of cancer. Another important application of 90 Y is radio synovectomy. This radionuclide has a half-life of 64 hours, emits long range beta particles (maximum energy of 2.3 MeV) and decays, without intermediate nuclides, to a stable daughter. 90 Y may be obtained carrier-free, generated by the decay of its parent 90 Sr (half-life=28 years). 90 Sr is a product from uranium fission, and due to its long half-life, can be indefinitely used, which is certainly advantageous. It is present in great amounts, and needs to be processed and purified in order to be used as raw material for the generators. Generators of 90 Sr- 90 Y may thus be used during various months, due to 90 Sr long half-life. Several methods for the separation of 90 Y from 90 Sr by solvent extraction and ion exchange have been reported in literature. Thanks to its simplicity, ion exchange techniques have been more commonly used for this generator system. The main objective of this work was to develop a methodology for the preparation of 90 Sr- 90 Y generators, using cationic exchange resins. In such method, 90 Sr is strongly adsorbed in the resin and 90 Y is eluted by a 0.003 M EDTA solution. According to the quality control carried out, results showed that elution yields are greater than 65%, thus confirming the efficiency of the separation method used.

  8. Experimental alteration of R7T7 glass in salt brines at 90 deg C and 150 deg C

    International Nuclear Information System (INIS)

    Godon, N.; Vernaz, E.; Gin, S.; Beaufort, D.; Thomassin, J.H.

    1991-01-01

    Static experiments have been developed to investigate the R7T7 glass corrosion in four natural salt brines (brines 1 and 3: pure halite, brines 2 and 4: high Mg, K fluid inclusions rich halite), at 90 deg C and 150 deg C with 0.7 cm -1 S/V ratio and at 11 different running times. Analysis of brines after alteration (pHmeter and ICP) added to a detailed study of the crystalline phases developed at the interface glass-brine (XRD,SEM and Microprobe), showed that the influence of the compositional difference is more important on the nature of the secondary phases formed than on the corrosion rate of the glass. After 91 days of alteration at 150 deg C stady states to be reached (after 40 days at 90 deg C). A long term experiment (1 year) is necessary to confirm this hypothesis. 7 refs., 7 figs., 2 tabs

  9. Mucoadhesive microspheres for gastroretentive delivery of acyclovir: in vitro and in vivo evaluation.

    Science.gov (United States)

    Dhaliwal, Sumeet; Jain, Subheet; Singh, Hardevinder P; Tiwary, A K

    2008-06-01

    The aim of the present investigation was to evaluate the potential use of mucoadhesive microspheres for gastroretentive delivery of acyclovir. Chitosan, thiolated chitosan, Carbopol 71G and Methocel K15M were used as mucoadhesive polymers. Microsphere formulations were prepared using emulsion-chemical crosslinking technique and evaluated in vitro, ex-vivo and in-vivo. Gelatin capsules containing drug powder showed complete dissolution (90.5 +/- 3.6%) in 1 h. The release of drug was prolonged to 12 h (78.8 +/- 3.9) when incorporated into mucoadhesive microspheres. The poor bioavailability of acyclovir is attributed to short retention of its dosage form at the absorption sites (in upper gastrointestinal tract to duodenum and jejunum). The results of mucoadhesion study showed better retention of thiolated chitosan microspheres (8.0 +/- 0.8 h) in duodenal and jejunum regions of intestine. The results of qualitative and quantitative GI distribution study also showed significant higher retention of mucoadhesive microspheres in upper GI tract. Pharmacokinetic study revealed that administration of mucoadhesive microspheres could maintain measurable plasma concentration of acyclovir through 24 h, as compared to 5 h after its administration in solution form. Thiolated chitosan microsphere showed superiority over the other formulations as observed with nearly 4.0-fold higher AUC(0-24) value (1,090 +/- 51 ng h/ml) in comparison to drug solution (281 +/- 28 ng h/ml). Overall, the result indicated prolonged delivery with significant improvement in oral bioavailability of acyclovir from mucoadhesive microspheres due to enhanced retention in the upper GI tract.

  10. DNA-assisted binding of microspheres on glass substrates and their laser-induced release

    International Nuclear Information System (INIS)

    Kim, Sejong; Geiss, Erik; Yu, Phillip; Papadimitrakopoulos, Fotios; Marcus, Harris L.

    2006-01-01

    DNA hybridization has been increasingly adopted in materials sciences due to its complementary nature of single stranded DNAs. This unique property could be potentially used in the realization of 2 dimensional (2D) arrays of colloidal microspheres as a precursor to further build more complicated superstructures. In order to precisely understand this DNA-assisted assembly of colloidal particles, we quantitatively assessed the surface density of grafted and hybridizing accessible DNA oligomers on both substrate and colloidal particles. The DNA grafting densities were determined by UV-Vis of dye-functionalized complementary DNA oligomers, in conjunction with theoretical models. The variations of the concentration of hybridized DNA as a function of parameters such as the number of DNA base pairs (bp), the length of spacer and the size of sphere were also investigated to determine the immobilization strength of colloidal microspheres on the substrate. Dehybridization of the particle was conducted by utilizing a focused laser beam. These results were also compared with the particle hybridization energies and modeled according to the sum of DNA bindings as a function of the number of hybridized bases

  11. Study on the coextraction of scandium-yttrium-lumogallion complex

    International Nuclear Information System (INIS)

    Okada, T.; Shimoishi, Y.; Miyata, H.; Toei, K.

    1977-01-01

    The coextraction of scandium-yttrium-lumogallion [LMG;4-chloro-6-(2,4-dihydroxyphenylazo)-1-hydroxybenzene-2-sulfonic acid] into diethyl ether has been studied. The acid dissociation constants of LMG, pKsub(a2) and pKsub(a3), were estimated to be 6.24 and 8.05 respectively. The composition of the complex extracted was determined by using the radioisotopes 46 Sc and 90 Y and by spectrophotometry of LMG and the ratio of the components was Sc:Y:LMG = 1:1:3. The coextraction scheme was discussed briefly. (author)

  12. On the use of hydrogen peroxide as a masking agent for the determination of yttrium in uranium oxide - yttrium oxide mixture

    International Nuclear Information System (INIS)

    Rastogi, R.K.; Chaudhuri, N.K.; Rizvi, G.H.; Subramanian, M.S.

    1985-01-01

    The use of peroxide as a masking agent for uranium during the EDTA titration of yttrium in an yttrium-uranium mixture containing large amounts of uranium was investigated. High acetate ion concentration was necessary to keep the peroxy complex of uranium in solution during the titration. It was observed that uranium could be tolerated up to 500 mg in the determination of yttrium with 0.5 ml of 30% hydrogen peroxide in approx. 1M acetate medium. The precision and accuracy of the method based on 16 determinations of yttrium at 6-16 mg level in the presence of 300 mg uranium was found to be +-0.2%. (author)

  13. Laser fusion experiments at 2 TW. [Argus system; implosion of D-T filled glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Storm, E.K.; Ahlstrom, H.G.; Boyle, M.J.

    1976-10-01

    The Lawrence Livermore Laboratory Solid State Laser System, Arqus, has successfully performed laser implosion experiments at power levels exceeding 2 TW. D-T filled glass microspheres have been imploded to yield thermonuclear reaction products in excess of 5 x 10/sup 8/ per event. Neutron and ..cap alpha.. time-of-flight measurements indicate that D-T ion temperatures of approximately 5-6 keV and a density confinement time product (n tau) of approximately 1 x 10/sup 12/ were obtained in these experiments. Typically two 40J, 40 psec pulses of 1.06 ..mu..m light were focused on targets using 20 cm aperture f/1 lenses, producing intensities at the target in excess of 10/sup 16/ W/cm/sup 2/. An extensive array of diagnostics routinely monitored the laser performance and the laser target interaction process. Measurements of absorption and asymmetry in both the scattered light distribution and the ion blow off is evidence for non-classical absorption mechanisms and density scale heights of the order of 2 ..mu..m or less. The symmetry of the thermonuclear burn region is investigated by monitoring the ..cap alpha..-particle flux in several directions, and an experiment to image the thermonuclear burn region is in process. These experiments significantly extend our data base and our understanding of laser induced thermonuclear implosions and the basic laser plasma interaction physics from the 0.4 to 0.7 TW level of previous experiments.

  14. [Optimization of calcium alginate floating microspheres loading aspirin by artificial neural networks and response surface methodology].

    Science.gov (United States)

    Zhang, An-yang; Fan, Tian-yuan

    2010-04-18

    To investigate the preparation and optimization of calcium alginate floating microspheres loading aspirin. A model was used to predict the in vitro release of aspirin and optimize the formulation by artificial neural networks (ANNs) and response surface methodology (RSM). The amounts of the material in the formulation were used as inputs, while the release and floating rate of the microspheres were used as outputs. The performances of ANNs and RSM were compared. ANNs were more accurate in prediction. There was no significant difference between ANNs and RSM in optimization. Approximately 90% of the optimized microspheres could float on the artificial gastric juice over 4 hours. 42.12% of aspirin was released in 60 min, 60.97% in 120 min and 78.56% in 240 min. The release of the drug from the microspheres complied with Higuchi equation. The aspirin floating microspheres with satisfying in vitro release were prepared successfully by the methods of ANNs and RSM.

  15. Embolization of Hepatic Arterial Branches to Simplify Hepatic Blood Flow Before Yttrium 90 Radioembolization: A Useful Technique in the Presence of Challenging Anatomy

    International Nuclear Information System (INIS)

    Karunanithy, Narayan; Gordon, Fabiana; Hodolic, Marina; Al-Nahhas, Adil; Wasan, Harpreet S.; Habib, Nagy; Tait, Nicholas P.

    2011-01-01

    Purpose: In the presence of variant hepatic arterial anatomy, obtaining whole-liver coverage with yttrium 90 (Y90) radioembolization may be challenging. The purpose of this study was to determine whether a technique whereby variant hepatic arterial branches are embolized and then Y90 is administered selectively into one remaining hepatic arterial branch results in whole-liver coverage and effective therapy. A retrospective comparison of treatment response was made between a group of patients who underwent this technique before Y90 administration and a group of patients who received standard Y90 administration as a single dose into the proper hepatic artery or in divided doses into the immediate hepatic artery branches. The rest of the workup and treatment were identical in both groups, including routine embolization of potential nonhepatic, nontarget vessels (e.g., the gastroduodenal artery). Methods: A total of 32 patients (mean age 56.9 years, range 39–77 years) treated with Y90 between June 2004 and March 2008 were analyzed. The primary malignancy was colorectal in 29, breast in 2, and cholangiocarcinoma in 1. Group 1 comprised 20 patients who had no alterations to their hepatic arterial supply. Group 2 comprised 12 cases who had undergone prior embolization of hepatic arterial branches before administration of Y90. The response to treatment was assessed by comparing standardized uptake value (SUV) on the pre- and postprocedure fludeoxyglucose positron emission tomographic studies of representative lesions within the right and left lobes of the liver. Results: In group 1, significant response (P < 0.001) was seen among right lobe lesions but not among left lobe lesions (P = 0.549). In group 2, there was a significant response among both right (P = 0.028) and left (P = 0.014) lobe lesions. No difference was found in the response of right lobe lesions (P = 0.726) between groups 1 and 2; a significantly greater response was found in group 2 compared to group 1 (P

  16. Intra-arterial therapy of neuroendocrine tumour liver metastases: comparing conventional TACE, drug-eluting beads TACE and yttrium-90 radioembolisation as treatment options using a propensity score analysis model

    Energy Technology Data Exchange (ETDEWEB)

    Minh, Duc Do; Gorodetski, Boris; Smolka, Susanne; Savic, Lynn Jeanette; Wainstejn, David [Charite Universitaetsmedizin, Campus Virchow Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Chapiro, Julius; Schlachter, Todd [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Huang, Qiang [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Capital Medical University, Department of Interventional Radiology, Beijing Chaoyang Hospital, Beijing (China); Liu, Cuihong [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Shandong Provincial Hospital Affiliated to Shandong University, The Ultrasound Department, Jinan (China); Lin, MingDe [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Philips Research North America, U/S Imaging and Interventions (UII), Cambridge, MA (United States); Gebauer, Bernhard [Charite Universitaetsmedizin, Campus Virchow Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Geschwind, Jean-Francois [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States)

    2017-12-15

    To compare efficacy, survival outcome and prognostic factors of conventional transarterial chemoembolisation (cTACE), drug-eluting beads TACE (DEB-TACE) and yttrium-90 radioembolisation (Y90) for the treatment of liver metastases from gastroenteropancreatic (GEP) neuroendocrine tumours (NELM). This retrospective analysis included 192 patients (58.6 years mean age, 56% men) with NELM treated with cTACE (N = 122), DEB-TACE (N = 26) or Y90 (N = 44) between 2000 and 2014. Radiologic response to therapy was assessed according to Response Evaluation Criteria in Solid Tumours (RECIST) and World Health Organization (WHO) criteria using periprocedural MR imaging. Survival analysis included propensity score analysis (PSA), median overall survival (MOS), hepatic progression-free survival, Kaplan-Meier using log-rank test and the uni- and multivariate Cox proportional hazards model (MVA). MOS of the entire study population was 28.8 months. As for cTACE, DEB-TACE and Y90, MOS was 33.8 months, 21.7 months and 23.6 months, respectively. According to the MVA, cTACE demonstrated a significantly longer MOS as compared to DEB-TACE (p <.01) or Y90 (p =.02). The 5-year survival rate after initial cTACE, DEB-TACE and Y90 was 28.2%, 10.3% and 18.5%, respectively. Upon PSA, our study suggests significant survival benefits for patients treated with cTACE as compared to DEB-TACE and Y90. This data supports the therapeutic decision for cTACE as the primary intra-arterial therapy option in patients with unresectable NELM until proven otherwise. (orig.)

  17. Hierarchical Mn₂O₃ Microspheres In-Situ Coated with Carbon for Supercapacitors with Highly Enhanced Performances.

    Science.gov (United States)

    Gong, Feilong; Lu, Shuang; Peng, Lifang; Zhou, Jing; Kong, Jinming; Jia, Dianzeng; Li, Feng

    2017-11-23

    Porous Mn₂O₃ microspheres have been synthesized and in-situ coated with amorphous carbon to form hierarchical C@Mn₂O₃ microspheres by first producing MnCO₃ microspheres in solvothermal reactions, and then annealing at 500 °C. The self-assembly growth of MnCO₃ microspheres can generate hollow structures inside each of the particles, which can act as micro-reservoirs to store biomass-glycerol for generating amorphous carbon onto the surfaces of Mn₂O₃ nanorods consisting of microspheres. The C@Mn₂O₃ microspheres, prepared at 500 °C, exhibit highly enhanced pseudocapacitive performances when compared to the particles after annealed at 400 °C and 600 °C. Specifically, the C@Mn₂O₃ microspheres prepared at 500 °C show high specific capacitances of 383.87 F g -1 at current density of 0.5 A g -1 , and excellent cycling stability of 90.47% of its initial value after cycling for 5000 times. The asymmetric supercapacitors assembled with C@Mn₂O₃ microspheres after annealed at 500 °C and activated carbon (AC) show an energy density of up to 77.8 Wh kg -1 at power density of 500.00 W kg -1 , and a maximum power density of 20.14 kW kg -1 at energy density of 46.8 Wh kg -1 . We can attribute the enhanced electrochemical performances of the materials to their three-dimensional (3D) hierarchical structure in-situ coated with carbon.

  18. Development of {sup 90}Sr-{sup 90}Y generators; Desenvolvimento de geradores de {sup 90}Sr-{sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Barrio, Graciela, E-mail: gracielabarrio@gmail.co [Pontificia Univ. Catolica de Sao Paulo (PUC-SP), SP (Brazil). Dept. de Fisica; Osso Junior, Joao Alberto, E-mail: jaossoj@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2007-07-01

    Yttrium-90 is a radioisotope of great interest in the field of Nuclear Medicine. It is considered one of the most important and most used radionuclides for radioimmunotherapeutical applications, especially promising for the treatment of certain types of cancer. Another important application of {sup 90}Y is radio synovectomy. This radionuclide has a half-life of 64 hours, emits long range beta particles (maximum energy of 2.3 MeV) and decays, without intermediate nuclides, to a stable daughter. {sup 90}Y may be obtained carrier-free, generated by the decay of its parent {sup 90}Sr (half-life=28 years). {sup 90}Sr is a product from uranium fission, and due to its long half-life, can be indefinitely used, which is certainly advantageous. It is present in great amounts, and needs to be processed and purified in order to be used as raw material for the generators. Generators of {sup 90}Sr-{sup 90}Y may thus be used during various months, due to {sup 90}Sr long half-life. Several methods for the separation of {sup 90}Y from {sup 90}Sr by solvent extraction and ion exchange have been reported in literature. Thanks to its simplicity, ion exchange techniques have been more commonly used for this generator system. The main objective of this work was to develop a methodology for the preparation of {sup 90}Sr-{sup 90}Y generators, using cationic exchange resins. In such method, {sup 90}Sr is strongly adsorbed in the resin and {sup 90}Y is eluted by a 0.003 M EDTA solution. According to the quality control carried out, results showed that elution yields are greater than 65%, thus confirming the efficiency of the separation method used.

  19. Study of the spheronization process of glass particles by the gravitational falling process for internal selective radiotherapy; Estudo do processo de esferolizacao por queda gravitacional de particulas vitreas visando a aplicacao em radioterapia interna seletiva

    Energy Technology Data Exchange (ETDEWEB)

    Barros Filho, E.C.; Martinelli, J.R., E-mail: eraldo.filho@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), SP (Brazil); Sene, F.F. [Centro Tecnologico da Marinha em Sao Paulo (CTMS), Sao Paulo, SP (Brazil)

    2011-07-01

    The internal selective radiotherapy is an alternative to treat hepatocellular carcinoma. Glass microspheres containing β{sup -} emitter radionuclide are introduced in the liver, and they are housed preferentially in the region where the cancer cells are located. The microspheres are trapped in the arterioles which feed the tumors, and the β{sup -} particles annihilate the cancer cells. The glass particles must be spherical to avoid unnecessary bleeding, and the particle size must be restricted to a range which optimizes the blocking effect and avoid the migration to other parts of the human body. The particle size distribution of microspheres is not easily predicted since the variation of the aspect ratio and the presence of agglomerates can influence the resulting particle size distribution. In the present work, the spheronization process to obtain microspheres from irregular shape glass particles with suitable diameter and shape for radiotherapy treatment is studied. (author)

  20. Biocompatibility Research of a Novel pH Sensitive Ion Exchange Resin Microsphere.

    Science.gov (United States)

    Liu, Hongfei; Shi, Shuangshuang; Pan, Weisan; Sun, Changshan; Zou, Xiaomian; Fu, Min; Feng, Yingshu; Ding, Hui

    2014-01-01

    The main objective of this study was to investigate biocompatibility and provide in-vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The general pharmacological studies consist of the effects of the pH sensitive ion exchange resin microsphere on the nervous system of mice, the functional coordination of mice, the hypnosis of mice treated with nembutal at subliminal dose, the autonomic activities of tested mice, and the heart rate, blood pressure, ECG and breathing of the anesthetic cats. The LD50 of pH sensitive ion exchange resin microsphere after oral administration was more than 18.84 g·Kg(-1). Mice were orally administered with 16 mg·Kg(-1), 32 mg·Kg(-1) and 64 mg·Kg(-1) of pH sensitive ion exchange resin microsphere and there was no significant influence on mice nervous system, general behavior, function coordination, hypnotic effect treated with nembutal at subliminal dose and frequency of autonomic activities. Within the 90 min after 5 mg·Kg(-1), 10 mg·Kg(-1), 20 mg·Kg(-1) pH sensitive ion exchange resin microsphere was injected to cat duodenum, the heart rate, blood pressure, breathing and ECG of the cats didn't make significant changes in each experimental group compared with the control group. The desirable pharmacological and toxicological behaviors of the pH sensitive ion exchange resin microsphere exhibited that it has safe biocompatibility and is possible for clinical use.

  1. A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging

    International Nuclear Information System (INIS)

    Rong Xing; Du Yong; Frey, Eric C

    2012-01-01

    Quantitative Yttrium-90 ( 90 Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging has shown great potential to provide reliable estimates of 90 Y activity distribution for targeted radionuclide therapy dosimetry applications. One factor that potentially affects the reliability of the activity estimates is the choice of the acquisition energy window. In contrast to imaging conventional gamma photon emitters where the acquisition energy windows are usually placed around photopeaks, there has been great variation in the choice of the acquisition energy window for 90 Y imaging due to the continuous and broad energy distribution of the bremsstrahlung photons. In quantitative imaging of conventional gamma photon emitters, previous methods for optimizing the acquisition energy window assumed unbiased estimators and used the variance in the estimates as a figure of merit (FOM). However, for situations, such as 90 Y imaging, where there are errors in the modeling of the image formation process used in the reconstruction there will be bias in the activity estimates. In 90 Y bremsstrahlung imaging this will be especially important due to the high levels of scatter, multiple scatter, and collimator septal penetration and scatter. Thus variance will not be a complete measure of reliability of the estimates and thus is not a complete FOM. To address this, we first aimed to develop a new method to optimize the energy window that accounts for both the bias due to model-mismatch and the variance of the activity estimates. We applied this method to optimize the acquisition energy window for quantitative 90 Y bremsstrahlung SPECT imaging in microsphere brachytherapy. Since absorbed dose is defined as the absorbed energy from the radiation per unit mass of tissues in this new method we proposed a mass-weighted root mean squared error of the volume of interest (VOI) activity estimates as the FOM. To calculate this FOM, two analytical expressions were derived for

  2. A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.

    Science.gov (United States)

    Rong, Xing; Du, Yong; Frey, Eric C

    2012-06-21

    Quantitative Yttrium-90 ((90)Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging has shown great potential to provide reliable estimates of (90)Y activity distribution for targeted radionuclide therapy dosimetry applications. One factor that potentially affects the reliability of the activity estimates is the choice of the acquisition energy window. In contrast to imaging conventional gamma photon emitters where the acquisition energy windows are usually placed around photopeaks, there has been great variation in the choice of the acquisition energy window for (90)Y imaging due to the continuous and broad energy distribution of the bremsstrahlung photons. In quantitative imaging of conventional gamma photon emitters, previous methods for optimizing the acquisition energy window assumed unbiased estimators and used the variance in the estimates as a figure of merit (FOM). However, for situations, such as (90)Y imaging, where there are errors in the modeling of the image formation process used in the reconstruction there will be bias in the activity estimates. In (90)Y bremsstrahlung imaging this will be especially important due to the high levels of scatter, multiple scatter, and collimator septal penetration and scatter. Thus variance will not be a complete measure of reliability of the estimates and thus is not a complete FOM. To address this, we first aimed to develop a new method to optimize the energy window that accounts for both the bias due to model-mismatch and the variance of the activity estimates. We applied this method to optimize the acquisition energy window for quantitative (90)Y bremsstrahlung SPECT imaging in microsphere brachytherapy. Since absorbed dose is defined as the absorbed energy from the radiation per unit mass of tissues in this new method we proposed a mass-weighted root mean squared error of the volume of interest (VOI) activity estimates as the FOM. To calculate this FOM, two analytical expressions were

  3. Yttrium ion implantation on the surface properties of magnesium

    International Nuclear Information System (INIS)

    Wang, X.M.; Zeng, X.Q.; Wu, G.S.; Yao, S.S.

    2006-01-01

    Owing to their excellent physical and mechanical properties, magnesium and its alloys are receiving more attention. However, their application has been limited to the high reactivity and the poor corrosion resistance. The aim of the study was to investigate the beneficial effects of ion-implanted yttrium using a MEVVA ion implanter on the surface properties of pure magnesium. Isothermal oxidation tests in pure O 2 at 673 and 773 K up to 90 min indicated that the oxidation resistance of magnesium had been significantly improved. Surface morphology of the oxide scale was analyzed using scanning electron microscope (SEM). Auger electron spectroscopy (AES) and X-ray diffraction (XRD) analyses indicated that the implanted layer was mainly composed of MgO and Y 2 O 3 , and the implanted layer with a duplex structure could decrease the inward diffusion of oxygen and reduce the outward diffusion of Mg 2+ , which led to improving the oxidation resistance of magnesium. Potentiodynamic polarization curves were used to evaluate the corrosion resistance of the implanted magnesium. The results show yttrium implantation could enhance the corrosion resistance of implanted magnesium compared with that of pure magnesium

  4. In vitro evaluation and intra-articular administration of biodegradable microspheres containing naproxen sodium.

    Science.gov (United States)

    Bozdağ, S; Caliş, S; Kaş, H S; Ercan, M T; Peksoy, I; Hincal, A A

    2001-01-01

    The dispersion of non-steroidal antiinflammatory drugs (NSAIDs) into biodegradable polymeric matrices have been accepted as a good approach for obtaining a therapeutic effect in a predetermined period of time meanwhile minimizing the side effects of NSAIDs. In the present study, it was aimed to prepare Naproxen Sodium (NS), (a NSAID) loaded microsphere formulation using natural Bovine Serum Albumin (BSA) and synthetic biodegradable polymers such as poly(lactide-co-glycolic acid) (PLGA) (50:50 MW 34,000 and 88,000 Da) for intra-articular administration, and to study the retention of the drug at the site of injection in the knee joint. NS incorporated microspheres were evaluated in vitro for particle size (the mean particle size; for BSA microspheres, 10.0 +/- 0.3 microm, for PLGA microspheres, 9.0 +/- 0.2 and 5.0 +/- 0.1 microm for MW 34,000 and 88,000 Da, respectively), yield value, drug loading, surface morphology and drug release. For in vivo studies, monoarticular arthritis was induced in the left knee joints of rabbits by using ovalbumin and Freund's Complete Adjuvant as antigen and adjuvant. A certain time (4 days) is allowed for the formation of arthritis in the knee joints, then the NS loaded microspheres were injected directly into the articular cavity. At specific time points, gamma scintigrams were obtained to determine the residence time of the microspheres in knee joints, in order to determine the most suitable formulation. This study indicated that PLGA, a synthetic polymer, is more promising than the natural type BSA microspheres for an effective cure of mono-articular arthritis in rabbits.

  5. Pathological changes in cystic craniopharyngiomas following intracavital 90Yttrium treatment

    International Nuclear Information System (INIS)

    Szeifert, G.T.; Julow, J.; Slowik, F.; Balint, K.; Lanyi, F.; Pasztor, E.

    1990-01-01

    Radiosurgery, using 90 Y injected directly into the cavity of cystic craniopharyngiomas produces remarkable reduction of tumour size and diminishes cyst fluid production. The authors have studied the histology of biopsy and autopsy material obtained from seven patients presented with cystic craniopharyngiomas. Histological examination was carried out before and after 90 Y silicate implantation. As an effect of 90 Y irradiation, histology of samples taken from the cyst wall revealed that the lining epithelial cell layer became destroyed and the cyst wall shrunk. Large amount of collagen fibres with focal hyaline degeneration was present. Proliferation of intimal cells and subendothelial connective tissue narrowing small vessel lumina also occurred. Considering that fibrotic tissue is more susceptible to shrink, the fibrosis induced by irradiation together with destruction of the squamous epithelium and vascular changes, might explain the reduction of the cyst volume and diminished fluid secretion after 90 Y treatment. (Authors)

  6. Surface modifications induced by yttrium implantation on low manganese-carbon steel

    Energy Technology Data Exchange (ETDEWEB)

    Caudron, E.; Buscail, H. [Univ. Blaise Pascal Clermont-Fd II, Le Puy en Velay (France). Lab. Vellave d' Elaboration et d' Etude des Materiaux; Haanapel, V.A.C.; Jacob, Y.P.; Stroosnijder, M.F. [Institute for Health and Consumer Protection, Joint Research Center, The European Commission, 21020, Ispra (Italy)

    1999-12-15

    Low manganese-carbon steel samples were ion implanted with yttrium. Sample compositions and structures were investigated before and after yttrium implantations to determine the yttrium distribution in the sample. Yttrium implantation effects were characterized using several analytical and structural techniques such as X-ray photoelectron spectroscopy, reflection high energy electron diffraction, X-ray diffraction, glancing angle X-ray diffraction and Rutherford backscattering spectrometry. In this paper it is shown that correlation between composition and structural analyses provides an understanding of the main compounds induced by yttrium implantation in low manganese-carbon steel. (orig.)

  7. Failure mode and effects analysis in a dual-product microsphere brachytherapy environment.

    Science.gov (United States)

    Younge, Kelly Cooper; Lee, Choonik; Moran, Jean M; Feng, Mary; Novelli, Paula; Prisciandaro, Joann I

    We performed a failure mode and effects analysis (FMEA) during the addition of a new microspheres product into our existing microsphere brachytherapy program to identify areas for safety improvements. A diverse group of team members from the microsphere program participated in the project to create a process map, identify and score failure modes, and discuss programmatic changes to address the highest ranking items. We developed custom severity ranking scales for staff- and institution-related failure modes to encompass possible risks that may exist outside of patient-based effects. Between both types of microsphere products, 173 failure mode/effect pairs were identified: 90 for patients, 35 for staff, and 48 for the institution. The SIR-Spheres program was ranked separately from the TheraSphere program because of significant differences in workflow during dose calculation, preparation, and delivery. High-ranking failure modes in each category were addressed with programmatic changes. The FMEA aided in identifying potential risk factors in our microsphere program and allowed a theoretically safer and more efficient design of the workflow and quality assurance for both our new SIR-Spheres program and our existing TheraSphere program. As new guidelines are made available, and our experience with the SIR-Spheres program increases, we will update the FMEA as an efficient starting point for future improvements. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  8. Effects of Amino-Functionalized Carbon Nanotubes on the Crystal Structure and Thermal Properties of Polyacrylonitrile Homopolymer Microspheres

    Directory of Open Access Journals (Sweden)

    Hailong Zhang

    2017-08-01

    Full Text Available Amino-functionalized multi-walled carbon nanotube (amino-CNT/polyacrylonitrile (PAN microspheres with diameter of about 300–400 nm were prepared by in situ polymerization under aqueous solution. The morphology, crystal structure, and thermal properties of amino-CNTs on a PAN homopolymer were investigated by scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectra, X-ray diffraction, and differential scanning calorimetry. The results showed that the amino-CNTs had a significant influence on the morphology of microspheres, and the PAN matrix were grafted onto the surface of amino-CNTs with interfacial bonding between them. The XRD studies showed that the crystal size of amino-CNT/PAN microspheres with lower crystallinity was bigger than in the control PAN homopolymer. The analysis of thermal properties indicated that the amino-CNT/PAN microspheres with lower glass transition temperature had a lower initial temperature and velocity of evolving heat during the exothermic processing as compared with the PAN homopolymer. These results suggested that the incorporation of amino-CNTs into the PAN homopolymer matrix was beneficial for controlling the heat released during the stabilization processing.

  9. Interactive Micromanipulation of Picking and Placement of Nonconductive Microsphere in Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Ning Cao

    2017-08-01

    Full Text Available In this paper, classified theoretical models, consisting of contact with and placement of microsphere and picking operations, are simplified and established to depict the interactive behaviors of external and internal forces in pushing manipulations, respectively. Sliding and/or rolling cases, resulting in the acceleration of micromanipulations, are discussed in detail. Effective contact detection is achieved by combining alterations of light-shadow and relative movement displacement between the tip-sphere. Picking operations are investigated by typical interactive positions and different end tilt angles. Placements are realized by adjusting the proper end tilt angles. These were separately conducted to explore the interactive operations of nonconductive glass microspheres in a scanning electron microscope. The experimental results demonstrate that the proposed contact detection method can efficiently protect the end-tip from damage, regardless of operator skills in initial positioning operations. E-beam irradiation onto different interactive positions with end tilt angles can be utilized to pick up microspheres without bending the end-tip. In addition, the results of releasing deviations away from the pre-setting point were utilized to verify the effectiveness of the placement tilt angles.

  10. Evaluation of a pyrex glass shield for the dose reduction in extremities to manipulate a {sup 90} Sr- {sup 90} Y generator; Evaluacion de un blindaje de vidrio pyrex para la reduccion de las dosis en extremidades al manipular un generador de {sup 90} Sr- {sup 90} Y

    Energy Technology Data Exchange (ETDEWEB)

    Ayra P, F.E.; Xiques C, A.; Torres B, M.B. [Centro de Isotopos, Carretera La Rada, Km 3 1/2, Guanabacoa, La Habana (Cuba)]. e-mail: feayra@centis.edu.cu

    2006-07-01

    The production of Y-90 of high activity it specifies (free of payee) for their use in radioimmunotherapy uses the Strontium 90 as isotope source. Depending on the method employee for the separation of both isotopes several types of generators are described in different bibliographies. The column generator used in the facilities of the Center of Isotopes requires of a frequent manipulation causing significant dose in the skin of the extremities due to the exhibition to the radiation beta of high energy. The properties of the shieldings for this radiation type have been well studied Y they consist in several publications. To be in correspondence with requirements of radiological protection in the Cuban legislation, the column was covered with a tube of glass pyrex of 5 mm of thickness and it was monitored the exposure with an ionization chamber. At the own time, the shielding using the Monte Carlo method was evaluated. It was used the MCNP 4C code to simulate the absorption of the beta particles generated in the process of disintegration of the Sr-90 and Y-90 in the glass shielding. The column generator and the fluence of beta particles were modeled in different points inside the shielding to determine if the experimentally measured values correspond to electrons that were not absorbed or to the weak stopping radiation generated in the glass due to the deceleration of these particles. A cylinder of 4 mm of diameter simulates the source (it dilutes) and a tube of walls of 6 mm of thickness simulates the shielding more the wall of the column around the generator. This it was divided in cells of 1 mm of thickness and the energy deposited in them was evaluated. The results show that all the electrons generated in the source are absorbed in the shielding and the exposure rates decrease in more of 78 times using the 5 mm of pyrex glass. The doses in extremities to the operators of the generator don't surpass the 70 mSv by year that is the dose restriction imposed in

  11. Determination of strontium-90 in soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C C

    1976-06-01

    The determination of /sup 90/Sr in soil by tri-n-butyl phosphate (TBP) is often interfered with iron which is always present in soil sample. Based on the method given by the U.S. Environmental Protection Agency, HClO/sub 4/ is added to remove iron ions while the soil sample is analyzed with TBP. The effect of different concentrations of HClO/sub 4/ on extraction yield of iron and chemical yield of yttrium is investigated. The experimental results show that 2N HClO/sub 4/ is the optimum concentration. The chemical yield of yttrium can reach about 60 percent, and all iron ions can be removed. This method has successfully been applied to analyze the soil samples taken from the site of the nuclear power plant in North Taiwan.

  12. Chitosan Microspheres as Radiolabeled Delivery Devices

    International Nuclear Information System (INIS)

    Permtermsin, Chalermsin; Ngamprayad, Tippanan; Phumkhem, Sudkanung; Srinuttrakul, Wannee; Kewsuwan, Prartana

    2007-08-01

    Full text: This study optimized conditions for preparing, characterizing, radiolabeled of chitosan microspheres and the biodistribution of 99mTc-Chitosan microspheres after intravenous administration. Particle size distribution of the microspheres was determined by light scattering. Zeta potential was studied by dynamic light scattering and electrophoresis technique. Biodistribution studies were performed by radiolabeling using 99mTc. The results shown that geometric mean diameter of the microspheres was found to be 77.26?1.96 ?m. Microsphere surface charge of chitosan microspheres was positive charge and zeta potential was 25.80 ? 0.46 mV. The labeling efficiency for this condition was more than 95% and under this condition was stable for at least 6 h. Radioactivity

  13. Yttrium and rare earths separation by ion exchange resin

    International Nuclear Information System (INIS)

    Pinatti, D.G.; Ayres, M.J.G.; Ribeiro, S.; Silva, G.L.J.P.; Silva, M.L.C.P.; Martins, A.H.

    1988-01-01

    The experimental results of yttrium and rare earths separation from Brazilian xenotime are presented. The research consist in five stage: 1) Preparation of yttrium, erbium and lutetium standard solutions, from solubilization of pure oxides 2) yttrium and rare earths separation by ion exchange chromatrography 3) Separation and recovery of EDTA 4) Precipitation and calcination and 4) Analytical control of process. (C.G.C.) [pt

  14. Preparation and properties of polyvinyl alcohol microspheres

    International Nuclear Information System (INIS)

    Campbell, J.H.; Grens, J.Z.; Poco, J.F.; Ives, B.H.

    1986-06-01

    Polyvinyl alcohol (PVA) microspheres, having a size range of ∼150- to 250-μm diameter with 1- to 5-μm wall thickness, have been fabricated using a solution droplet technique. The spheres were developed for possible use on the Lawrence Livermore National Laboratory (LLNL) Inertial Confinement Fusion (ICF) Program. PVA, a polymer chosen based on earlier survey work carried out at KMS Fusion, Inc., has good strength, low hydrogen permeability, is optically transparent, and water soluble. The latter property makes it safe and easy to use in our droplet generator system. A unique dual-orifice droplet generator was used to prepare the spheres. The droplet generator operating conditions and the column processing parameters were chosen using results from our 1-D model calculations as a guide. The polymer microsphere model is an extension of the model we developed to support the glass sphere production. After preparation, the spheres were physically characterized for surface quality, sphericity, wall thickness (and uniformity), and size. We also determined the buckling pressure for both uncoated and CH-coated spheres. Radiation stability to beta decay (from tritium) was evaluated by exposing the spheres to a 7-keV electron beam. The results from these and other physical property measurements are presented in this report

  15. Synthesis of magnetic polymeric microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Gervald, A Yu; Gritskova, Inessa A; Prokopov, Nikolai I [M.V. Lomonosov Moscow State Academy of Fine Chemical Technology, Moscow (Russian Federation)

    2010-05-13

    The key types of magnetic polymeric microspheres are considered. Methods of synthesis of different types of magnetic nanoparticles and of preparation of stable magnetic fluids on their basis are outlined. The overview of the methods for the manufacture of magnetic polymeric microspheres is presented. The effect of the synthesis conditions on the characteristics of magnetic polymeric microspheres such as the diameter and the particle size distribution and the content of magnetic material is discussed by particular examples. The application fields of magnetic polymeric microspheres are briefly surveyed.

  16. Synthesis of magnetic polymeric microspheres

    International Nuclear Information System (INIS)

    Gervald, A Yu; Gritskova, Inessa A; Prokopov, Nikolai I

    2010-01-01

    The key types of magnetic polymeric microspheres are considered. Methods of synthesis of different types of magnetic nanoparticles and of preparation of stable magnetic fluids on their basis are outlined. The overview of the methods for the manufacture of magnetic polymeric microspheres is presented. The effect of the synthesis conditions on the characteristics of magnetic polymeric microspheres such as the diameter and the particle size distribution and the content of magnetic material is discussed by particular examples. The application fields of magnetic polymeric microspheres are briefly surveyed.

  17. Preparation and microwave absorbing property of Ni–Zn ferrite-coated hollow glass microspheres with polythiophene

    Energy Technology Data Exchange (ETDEWEB)

    Li, Lindong; Chen, Xingliang; Qi, Shuhua, E-mail: qishuhuanwpu@163.com

    2016-11-01

    The composite of hollow glass microspheres (HMG) coated by Ni{sub 0.7}Zn{sub 0.3}Fe{sub 2}O{sub 4} particles was fabricated via sol–gel method, and then the ternary composite (HMG/Ni{sub 0.7}Zn{sub 0.3}Fe{sub 2}O{sub 4}/PT) was synthesized by in situ polymerization. The electrical property, magnetic performance and reflection loss of the composites were measured, and the results suggest that the conductivity and the saturation magnetization (Ms) of HMG/Ni{sub 0.7}Zn{sub 0.3}Fe{sub 2}O{sub 4}/PT reach 6.87×10{sup −5} S/cm and 11.627 emu/g, respectively. The ternary composite has good microwave absorbing properties (R{sub min}=−13.79 dB at 10.51 GHz) and the bandwidth less than −10 dB can reach 2.6 GHz (from 9.4 to 12.0 GHz) in X band (8.2–12.4 GHz). The morphology and chemical structure of the samples were measured through scanning electron microscopy (SEM), X-Ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). This paper also analyzes the relationship between the reflection loss of the absorber and its thickness. - Highlights: • This manuscript synthesized HMG/Ni{sub 0.7}Zn{sub 0.3}Fe{sub 2}O{sub 4}/PT composites. • The surface morphology, electrical property, magnetic performance and reflection loss of the composites were measured. • This paper also analyzed the relationship between the reflection loss of the absorber and its thickness.

  18. Ceramic microspheres for cementing applications

    NARCIS (Netherlands)

    2011-01-01

    A method and apparatus for manufacturing ceramic microspheres from industrial slag. The microspheres have a particle size of about 38 microns to about 150 microns. The microspheres are used to create a cement slurry having a density of at least about 11 lbs/g. The resultant cement slurry may then be

  19. Ceramic microspheres for cementing applications

    NARCIS (Netherlands)

    2010-01-01

    A method and apparatus for manufacturing ceramic microspheres from industrial slag. The microspheres have a particle size of about 38 microns to about 150 microns. The microspheres are used to create a cement slurry having a density of at least about 11 lbs/g. The resultant cement slurry may then be

  20. Ceramic microspheres for cementing applications

    NARCIS (Netherlands)

    2012-01-01

    A method and apparatus for manufacturing ceramic microspheres from industrial slag. The microspheres have a particle size of about 38 microns to about 150 microns. The microspheres are used to create a cement slurry having a density of at least about 11 lbs/g. The resultant cement slurry may then be

  1. Laser emission in Nd3+ doped barium–titanium–silicate microspheres under continuous and chopped wave pumping in a non-coupled pumping scheme

    International Nuclear Information System (INIS)

    Martín, L L; Pérez-Rodríguez, C; Martín, I R; Navarro-Urrios, D; Ferrarese-Lupi, F; Garrido, B; Montserrat, J; Dominguez, C; Capuj, N

    2013-01-01

    Laser action using non-coupled excitation and detection of microspheres made of Nd 3+ doped barium–titanium–silicate glass has been demonstrated and measured. The microspheres have also been successfully deposited over Si 3 N 4 strip waveguides with a SiO 2 separation layer, thus enabling the laser emission extraction onto a CMOS compatible photonic circuit. The dynamics of the lasing wavelength and intensity has been studied as a function of the pump power and interpreted in terms of thermal effects generated through non-radiative recombination of the excited ions. (paper)

  2. Method for chromatographically recovering scandium and yttrium

    International Nuclear Information System (INIS)

    Snyder, T.S.; Stoltz, R.A.

    1991-01-01

    This paper describes a method for chromatographically recovering scandium and yttrium from the residue of a sand chlorinator. It comprises: providing a residue from a sand chlorinator, the residue containing scandium, yttrium, sodium, calcium and at least one radioactive metal of the group consisting of radium, thorium and uranium; digesting the residue with an acid to produce an aqueous liquid containing scandium, yttrium, sodium, calcium and at least one radioactive metal of the group consisting of radium, thorium and uranium; feeding the metal containing liquid through a cation exchanger; eluding the cation exchanger with an acid eluant to to produce: a first eluate containing at least half of the total weight of the calcium and sodium in the feed liquid; a second eluate containing at least half of the total weight of the one or more radioactive metals in the feed liquid; a third eluate containing at least half of the yttrium in the feed liquid, and a fourth eluate containing at least half of the weight of the scandium in the feed liquid

  3. Reaction of yttrium polonides with carbon dioxide

    International Nuclear Information System (INIS)

    Abakumov, A.S.; Khokhlov, A.D.; Reznikova, N.F.

    1986-01-01

    It has been proved that heating of yttrium and tantalum in carbon dioxide to 500 and 800 0 C alters the gas phase composition, causing formation of carbon monoxide and reduction of oxygen content. A study of the thermal stability of yttrium polonides in carbon dioxide showed that yttrium sesqui- and monopolonides decompose at 400-430 0 C. The temperature dependence of the vapor pressure of polonium obtained upon decomposition of the referred polonides has been determined in a carbon dioxide environment radiotensometrically. The enthalpy of the process calculated from this dependence is close to the enthalpy of vaporization of elemental polonium in vacuo. The mechanism of the reactions has been suggested

  4. Separation of PCR-ready DNA from dairy products using magnetic hydrophilic microspheres and poly(ethylene glycol)-NaCl water solutions

    Energy Technology Data Exchange (ETDEWEB)

    Rittich, Bohuslav [Masaryk University, Faculty of Science, Institute of Experimental Biology, Tvrdeho 14, CZ-611 37 Brno (Czech Republic); Brno University of Technology, Faculty of Chemistry, Institute of Food Science and Biotechnology, Purkynova 464/118, CZ-612 00 Brno (Czech Republic)], E-mail: rittich@sci.muni.cz; Spanova, Alena [Masaryk University, Faculty of Science, Institute of Experimental Biology, Tvrdeho 14, CZ-611 37 Brno (Czech Republic); Brno University of Technology, Faculty of Chemistry, Institute of Food Science and Biotechnology, Purkynova 464/118, CZ-612 00 Brno (Czech Republic); Salek, Petr [Brno University of Technology, Faculty of Chemistry, Institute of Food Science and Biotechnology, Purkynova 464/118, CZ-612 00 Brno (Czech Republic); Nemcova, Petra [Masaryk University, Faculty of Science, Institute of Experimental Biology, Tvrdeho 14, CZ-611 37 Brno (Czech Republic); Trachtova, Stepanka [Brno University of Technology, Faculty of Chemistry, Institute of Food Science and Biotechnology, Purkynova 464/118, CZ-612 00 Brno (Czech Republic); Horak, Daniel [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovsky Sq. 2, CZ-162 06 Prague (Czech Republic)

    2009-05-15

    Carboxyl group-containing magnetic nonporous poly(2-hydroxyethyl methacrylate-co-glycidyl methacrylate) (P(HEMA-co-GMA)) and magnetic glass microspheres were used for the isolation of bacterial DNA. P(HEMA-co-GMA) microspheres were prepared by the dispersion polymerization in toluene/2-methylpropan-1-ol mixture in the presence of magnetite nanoparticles obtained by coprecipitation of Fe(II) and Fe(III) salts with ammonium hydroxide. Carboxyl groups were then introduced by oxidation of the microspheres with potassium permanganate. The most extensive DNA recovery was achieved at PEG 6000 concentrations of 12% or 16% and 2 M NaCl. The method proposed was used for bacterial DNA isolation from different dairy products containing Bifidobacterium and Lactobacillus cells. The presence of target DNA and the quality of isolated DNA were checked by polymerase chain reaction (PCR) amplification with specific primers.

  5. Simultaneous Determination of Glass Transition Temperatures of Several Polymers.

    Science.gov (United States)

    He, Jiang; Liu, Wei; Huang, Yao-Xiong

    2016-01-01

    A simple and easy optical method is proposed for the determination of glass transition temperature (Tg) of polymers. Tg was determined using the technique of microsphere imaging to monitor the variation of the refractive index of polymer microsphere as a function of temperature. It was demonstrated that the method can eliminate most thermal lag and has sensitivity about six fold higher than the conventional method in Tg determination. So the determined Tg is more accurate and varies less with cooling/heating rate than that obtained by conventional methods. The most attractive character of the method is that it can simultaneously determine the Tg of several polymers in a single experiment, so it can greatly save experimental time and heating energy. The method is not only applicable for polymer microspheres, but also for the materials with arbitrary shapes. Therefore, it is expected to be broadly applied to different fundamental researches and practical applications of polymers.

  6. Yttrium implantation effects on extra low carbon steel and pure iron

    Energy Technology Data Exchange (ETDEWEB)

    Caudron, E.; Buscail, H. [Clermont-Ferrand-2 Univ., Le Puy en Velay (France). Lab. Vellave d`Elaboration; Jacob, Y.P.; Stroosnijder, M.F. [Institute for Advanced Materials, Joint Research Center, The European Commission, 21020, Ispra (Vatican City State, Holy See) (Italy); Josse-Courty, C. [Laboratoire de Recherche sur la Reactivite des Solides, UMR 56-13 CNRS, UFR Sciences et Techniques, 9 Avenue A. Savary, B.P. 400, 21011, Dijon Cedex (France)

    1999-05-25

    Extra low carbon steel and pure electrolytic iron samples were yttrium implanted using ion implantation technique. Compositions and structures of pure iron and steel samples were investigated before and after yttrium implantation by several analytical and structural techniques (RBS, SIMS, RHEED and XRD) to observe the yttrium implantation depth profiles in the samples. This paper shows the different effects of yttrium implantations (compositions and structures) according to the implanted sample nature. (orig.) 23 refs.

  7. Radiochemical schemes of obtaining 89Sr and 90Y radionuclides

    International Nuclear Information System (INIS)

    Usarov, Z. O.

    2010-03-01

    Key words: strontium-89, yttrium-90, extraction and extraction-chromatographic purification of radionuclides, radiopharmaceuticals. Subjects of research: strontium-89 and yttrium-90 radionuclides and their chloride forms. Purpose of work is developing of radiochemical technologies on obtaining of 89 Sr and 90 Y on the WWR-SM reactor with high radionuclide purity. Methods of research: extraction and extraction-chromatographic methods of radionuclides separation, beta- and gamma-spectrometric methods of activity measuring. The results obtained and their novelty: Were determined the conformity to laws of Y and Sr distribution in two-phase systems TBP-HNO 3 , TBP-NH 4 NO 3 , TBP-HCI, HDEHP-NO 3 , HDEHP-NH 4 NO 3 and HDEHP-HCI. Were determined the conformity to laws of Y and Sr distribution in systems with craun ethers DB-18K-6 and DTBDB-18K-6 from water solutions of HNO 3 . Radiochemical technologies on obtaining of 89 Sr and 90 Y radionuclides including radiochemical process of yttrium target with using the systems TBP-HNO 3 and HDEHP/Teflone were developed. Practical value: the radiochemical technology of obtaining 89 Sr with high radionuclide purity was developed. The method of preparation a chloride compound of 89 SrCl 2 which is used as a drug form for preparation of 89 Sr- 'Metastron' was developed. The relatively simple method of on the way obtaining 90 Y in the reactor with high radionuclidic purity that is useful for follow using in medical practice was offered. Degree of embed and economic effectivity: the developed technologies have approbation in manufacturing conditions in Radiopreparat Enterprise of INP AS RU and were offered for receiving of domestic preparations against of import foreign analogues. The statement about using the invention by obtained patent is attached to dissertation. Field of application: the received results will be introduced in manufacture at Radiopreparat Enterprise of INP AS RU for receiving of domestic preparations

  8. Country report: Poland. 1. Determination of 90Sr in 90YCL3 solution using DGA and SR-Spec resins (extraction chromatography) and by TLC according to USP. 2. Preliminary investigation on antibody biotinylation. 3. The development of method for preparation of human albumin microspheres as potential radionuclide carriers for diagnostic and therapeutic use. 4. Preparation of radiocolloids for radiosynovectomy using radionuclides of various beta energies

    International Nuclear Information System (INIS)

    Pawlak, D.; Mikolajczak, R.; Korsak, A.; Dziel, T.; Parus, J.L.; Byszewska-Szpocinska, E.; Jakubowska, E.; Mikolajczak, R.; Jaroń, A.; Pijarowska, J.; Iller, E.; Mikolajczak, W.

    2010-01-01

    1. • It seems that strontium can be more efficiently eluted for the DGA resin than form the Sr-spec resin. Paper chromatography (USP) method provides good resolution of Y and Sr, more results are needed to evaluate results statistically. Comparison of paper chromatography (USP) with paper extraction chromatography was not possible due to the problems in purchasing of the KSM-17. Further works in order to determine detection and determination limits of each of proposed methods are planned. 2. • The preliminary investigation on antibody biotinylation has been performed using commercially available polyclonal human immunoglobulin IgG, mw 150 kDa (Biomed Sp.z o.o, Lublin). Sulfo-NHS –Biotin (Pierce Biotechnology) was used as biotinylating agent. Activated biotin as sulfosuccinimidyl-6-[biotin-amido]hexanoate. is one of the commonly used reagent for proteins biotinylation. Sulfo-NHS-biotin effectively reacts at pH 7-9 with primary amino groups (- NH2) of proteins provided by lysine residues and Nterminus of polypeptide, forming stable amide bond. This reagent dissolves well in water. 3. • The average production yield of HAM for receiving the desired size range between 10-32 μm amounts to 84% and the mean size of particles was estimated to about 15 μm. Optical micrographs show microspheres as very regular spherical forms with quite smooth surfaces and rather narrow spread of size in the selected range. The labelling yields determined as relation of measured radioactivity remaining in the membrane filter to the total radioactivity were > 95% for 99mTc-HAM complex and > 98% for 90Y–X-HAM and 177Lu-X-HAM complexes. Labelled modified microspheres showed high in vitro stability in human plasma with only 4-5% loss of radioactivity from the surface after 48 h of incubation. 4. • The aim of the project is synthesis of monodispersive particles of yttrium citrate and characterization of its surface with instrumental techniques (collaboration with Maria Curie

  9. Effects of radiolysis on yttrium-90-labeled Lym-1 antibody preparations.

    Science.gov (United States)

    Salako, Q A; O'Donnell, R T; DeNardo, S J

    1998-04-01

    The physical half-life of 2.6 days and 2.2 MeV beta emissions of 90Y provide excellent properties for radioimmunotherapy applications. However, the clinically useful beta particles may be a source of radiation-induced damage of 90Y-labeled immunoconjugate radiopharmaceuticals during preparation or short-term storage. The stability of 90Y-labeled Lym-1 antibody was studied in standard radiopharmacy conditions to establish a formulation at which radiolysis is not a problem. Lym-1-21T-BAD immunoconjugate intermediate was prepared according to our standard procedure, then labeled with 90Y at 1, 2, 4 and 9.4 mCi/mg Lym-1 using 0.5 M tetramethylammonium acetate, pH 7, labeling buffer. Each mixture was challenged in diethylenetriaminepentaacetic acid to remove nonspecifically bound 90Y. The 90Y-21T-BAD-Lym-1 products were purified by centrifuged molecular sieving column chromatography. The radiochemical purity and immunoreactivity of each preparation was monitored daily by high-performance liquid chromatography (HPLC) and solid-phase radioimmunoassay, respectively, for 3 days. The preparation at 2 mCi/mg was also formulated in 4% (wt/vol) human serum albumin (HSA) overall and at 9.4 mCi/mg in five-fold water, 4 and 10% (wt/vol) HSA overall; all were monitored as above. The monomeric quality and purity profile of products at 1 and 2 mCi/mg were retained (> or = 80%) as was their immunoreactivity (> or = 75%) over 3 days. The radiochemical purity and immunoreactivity of the product at 4 mCi/mg declined to 65% and 28%, respectively, by 3 days after preparation and in just 48 hr, the product at 9.4 mCi/mg had degraded to 21% in radiochemical purity with only 3% immunoreactivity. The current HPLC data and earlier published chromatographic evidence did not support a compromised radiochemical integrity of 90Y-DOTA complexes by loss of 90Y from the DOTA chelate. Radiolysis of 90Y-labeled antibody preparations did not appear to be a problem at 90Y-21T-BAD-Lym-1 products < or = 2 m

  10. EPR of radiation defects in lithium-oxyfluoride glass ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Fedotovs, A; Rogulis, U; Sarakovskis, A; Dimitrocenko, L, E-mail: andris-f@navigator.l [Institute of Solid State Physics, University of Latvia, Kengaraga st. 8, LV-1063, Riga (Latvia)

    2010-11-01

    We studied oxyfluoride composites based on lithium silicate glasses with yttrium fluorides and rare-earth dopants. The electron paramagnetic resonance (EPR) has been used to obtain information about radiation induced defects in these materials. Spectra have been measured before and after X-ray irradiation at room temperature and at liquid nitrogen temperature. Fluoride crystallites within samples were created by means of thermal treatment at specific temperatures. EPR spectra of radiation induced defects in oxyfluoride glass ceramics, in which crystallites have not been yet created, show no explicit hfs interaction of fluorine nuclei. However, in glass ceramics, which already contains fluoride crystallites, the hfs characteristic to fluorine nuclei appears in the EPR spectra. EPR hyperfine structure could be explained within a model of an F-type centre in YF{sub 3} crystalline phase.

  11. EPR of radiation defects in lithium-oxyfluoride glass ceramics

    Science.gov (United States)

    Fedotovs, A.; Rogulis, U.; Sarakovskis, A.; Dimitrocenko, L.

    2010-11-01

    We studied oxyfluoride composites based on lithium silicate glasses with yttrium fluorides and rare-earth dopants. The electron paramagnetic resonance (EPR) has been used to obtain information about radiation induced defects in these materials. Spectra have been measured before and after X-ray irradiation at room temperature and at liquid nitrogen temperature. Fluoride crystallites within samples were created by means of thermal treatment at specific temperatures. EPR spectra of radiation induced defects in oxyfluoride glass ceramics, in which crystallites have not been yet created, show no explicit hfs interaction of fluorine nuclei. However, in glass ceramics, which already contains fluoride crystallites, the hfs characteristic to fluorine nuclei appears in the EPR spectra. EPR hyperfine structure could be explained within a model of an F-type centre in YF3 crystalline phase.

  12. A model for dose estimation in therapy of liver with intraarterial microspheres

    International Nuclear Information System (INIS)

    Zavgorodni, S.F.

    1996-01-01

    Therapy with intraarterial microspheres is a technique which involves incorporation of radioisotope-labelled microspheres into a capillary bed of tumour and normal tissue. Beta-emitters such as 90 Y and 166 Ho are used for this purpose. This technique provides tumour to normal tissue (TNT) dose ratios in the range of 2-10 and demonstrates significant clinical benefit, which could potentially be increased with more accurate dose predictions and delivery. However, dose calculations in this modality face the difficulties associated with nonuniform and inhomogeneous activity distribution. Most of the dose calculations used clinically do not account for the nonuniformity and assume uniform activity distribution. This paper is devoted to the development of a model which would allow more accurate prediction of dose distributions from microspheres. The model calculates dose assuming that microspheres are aggregated into randomly distributed clusters, and using precomputed dose kernels for the clusters. The dose kernel due to a microsphere cluster was found by numerical integration of a point source dose kernel over the volume of the cluster. It is shown that a random distribution of clusters produces an intercluster distance distribution which agrees well with the one measured by Pillai et al in liver. Dose volume histograms (DVHs) predicted by the model agree closely with the results of Roberson et al for normal tissue and tumour. Dose distributions for different concentrations and types of radioisotope, as well as for tumours of different radii, have been calculated to demonstrate the model's possible applications. (author)

  13. Yttrium-90 Needles in Interstitial Beta-Ray Therapy; Les Aiguilles d'Yttrium-90 en Endo-Electron-Therapie (Betatherapie Interstitielle); ИГЛЫ ИЗ ИТТРИЯ-90 ДЛЯ ЭНДОЭЛЕКТРОННОЙ ТЕРАПИИ ВНУТРИТКАНЕВОЙ БЕТА-ТЕРАГИ; Agujas de Itrio-90 en la Endo-Electronterapia (Betaterapia Intersticial)

    Energy Technology Data Exchange (ETDEWEB)

    Pierquin, B.; Mortreuil, M.; Beyer, H.; Dutreix, J.; Chassagne, D.; Galle, P.; Jammes, R. [Centre d' Etudes Nucleaires, Saclay (France)

    1963-03-15

    The Technical Unit for Interstitial Irradiation Therapy by Radioisotopes, of the Gustave Roussy Institute is at present studying, in collaboration with the Saclay Nuclear Centre, some therapeutic applications of interstitial beta-therapy using yttrium-90. Equipment: The needles consist of a stainless-steel tube, 1-mm diam., 0.1-mm wall thickness and 30 or 40 mm in length, closed at one end by a sharp point and at the other by a projecting head for attaching a pull-out wire. The yttrium oxide cylinders or seeds (5 mm x 0.6 mm) are irradiated for one week at a flux of 2.7 x 10{sup 12} n/cm{sup 2}s and are loaded three or five in each needle. Dosimetry: These yttrium-90 needles are supplied by the Saclay Centre with a standard activity of 1-1.5 me/cm (radioactive length). The activity is monitored both by a 4-{pi} counter and by a film densitometer. The reference dose is calculated by standard method at 2 mm from the tube wall assuming, with a certain approximation, a dose-rate of 10 rad/min for an activity of 1 me/cm. Therapeutic applications: Yttrium-90 needle radiobiology is still an almost unexplored field. The rapid fall-off in the dose beyond 3 mm from the needle wall causes difficulty in obtaining uniform distribution of irradiation in the treated tissues. In principle, the positioning of needles at 5 - 6 mm distance one from another is a possibility, but requires an implanting device capable of extremely delicate control, as an error of 1 or 2mm may cause too many hot or cold points. For that reason the authors decided to use the needles, at a first stage, in benign vascular tumours, with no biological attempt to obtain uniform irradiation of the tissue, the aim being confined to creating sclerotic areas in bands centred around the needles and separated by areas of tissue having received little or no irradiation. In this way it was-hoped to obtain an adequate sclerogenous effect in a certain number of tuberous angiomas while at the same time giving the

  14. Developing of Ytrium-90 Generator Based on Extraction Chromatography with Crown Ether

    International Nuclear Information System (INIS)

    Yassine, T.; Mukhallalati, Ch.H.

    2009-01-01

    high pure ytrium-90. Considering the specific characterizations of Sr-Spec resin which Show, that the higher distribution coefficient of strontium laoke place in 3M nitric acid solution, while it drops dramatically with decreasing the acidity. The distribution coefficient of Yttrium 90 at this concentration is almost Zero. This makes the Separation of Yttrium from strontium in 3M nitric acid is near ideal. Column study showed that almost complete separation of Yttrium-90 from strontium-90 could be achieved by using column (0.8 x 31 cm) containing about 3gr of Sr-Spec resin. But due to technical Considerations such as recovery, of strontium-90 minimizing the volume of the resin was distributed a more than one column. Separations were carried out on one, two and three columns, (0.4x21Cm) each contains one gram of resin are used as safety columns for further purification. For purification we used (AG 50W X12) resin to remove any traces of organic materials and trace element present. 5 mCi was taken from yttrium90 for quality control using Sr -spec column. The breakthrough of 90 Sr was more than 10-7. The eluate volume increases with the number of columns but strontium break through decreases. These results led to consider the three column designees. (author)

  15. Bioactivity of Y2O3 and CeO2 doped SiO2-SrO-Na2O glass-ceramics.

    Science.gov (United States)

    Placek, L M; Keenan, T J; Wren, A W

    2016-08-01

    The bioactivity of yttrium and cerium are investigated when substituted for Sodium (Na) in a 0.52SiO2-0.24SrO-0.24-xNa2O-xMO glass-ceramics (where x = 0.08 and MO = Y2O3 or CeO2). Bioactivity is monitored through pH and inductively coupled plasma-optical emission spectrometry where pH of simulated body fluid ranged from 7.5 to 7.6 and increased between 8.2 and 10.0 after 14-day incubation with the glass-ceramic disks. Calcium (Ca) and phosphorus (P) levels in simulated body fluid after incubation with yttrium and cerium containing disks show a continual decline over the 14-day period. In contrast, Con disks (not containing yttrium or cerium) caused the elimination of Ca in solution after 1 day and throughout the incubation period, and initially showed a decline in P levels followed by an increase at 14 days. Scanning electron microscopy and energy dispersive spectroscopy confirmed the presence of Ca and P on the surface of the simulated body fluid-incubated disks and showed precipitates on Con and HCe (8 mol% cerium) samples. Cell viability of MC3T3 osteoblasts was not significantly affected at a 9% extract concentration. Optical microscopy after 24 h cell incubation with disks showed that Con samples do not support osteoblast or Schwann cell growth, while all yttrium and cerium containing disks have direct contact with osteoblasts spread across the wells. Schwann cells attached in all wells, but only showed spreading with the HY-S (8 mol% yttrium, heated to sintering temperature) and YCe (4 mol% yttrium and cerium) disks. Scanning electron microscopy of the compatible disks shows osteoblast and sNF96.2 Schwann cells attachment and spreading directly on the disk surfaces. © The Author(s) 2016.

  16. Glass dissolution at 20, 40, 70 and 90 C: Short-term effects of solution chemistry and long-term Na release

    International Nuclear Information System (INIS)

    Bakel, A.J.; Ebert, W.L.; Strachan, D.M.

    1996-01-01

    The corrosion behavior of a borosilicate glass containing 20 mass 5 Na 2 O was assessed using static dissolution tests. This glass (LD6-5412) is representative of high Na glasses that may be used to stabilize Hanford low-level radioactive waste. The normalized mass loss (NL) decreases as NL(Na) ∼ NL(B) > NL(Si) in 20 and 40 C for tests conducted at glass surface area to leachant volume (S/V) ratio of 10 m -1 , and decreases as NL(Na) > NL(B) ∼ NL(Si) in 90 C tests conducted at 10 m -1 and in all tests conducted at higher S/V. The difference in the corrosion behavior is probably caused by the influence of dissolved glass components in the leachates. The NL(Na) is greater than the NL(B) or NL(Si) in all the tests conducted. Results from long-term tests at 2,000 m -1 show that the preferential release of Na persists for longer than one year at all temperatures and indicate that Na is released from this glass by an ion exchange process

  17. Treatment of metastasis localizations by intratumoral injection of radionuclide microsphere

    International Nuclear Information System (INIS)

    Tuo Peiyu; Pang Yan; Zhu Dianqing; Chang Keli; Zhu Yanjia

    2001-01-01

    Objective: To evaluate the therapeutic effects of radionuclide-labeled microsphere by intratumoral injection into 18 patients with superficial metastasis tumor for treatment. Methods: 18 patients with superficial metastasis were treated with radionuclide-labeled microsphere ( 90 Y-GTMS and 32 P-GTMS) by multi-point intratumoral injection. Each injection dose was 11.1-18.5 MBq/g (tumor). Results: 1 patient was relieved completely, 9 were relieved partly, 5 were improved and 3 kept stable. The total rate of relief and virtual value were 55.6% and 83.3% respectively. Conclusion: Topical treatment by using radionuclide may help diminish the tumor, control its progress and ease the symptoms. Thus it can be used as a supplement of routine treatment of tumors and it should do some work in therapy of malignant tumors in late stages

  18. Dose distribution to spinal structures from intrathecally administered yttrium-90

    Science.gov (United States)

    Mardirossian, George; Hall, Michael; Montebello, Joseph; Stevens, Patrick

    2006-01-01

    Previous treatment of cerebrospinal fluid (CSF) malignancies by intrathecal administration of 131I-radiolabelled monoclonal antibodies has led to the assumption that more healthy tissue will be spared when a pure beta-emitter such as 90Y replaces 131I. The purpose of this study is to compare and quantitatively evaluate the dose distribution from 90Y to the CSF space and its surrounding spinal structures to 131I. A 3D digital phantom of a section of the T-spine was constructed from the visible human project series of images which included the spinal cord, central canal, subarachnoid space, pia mater, arachnoid, dura mater, vertebral bone marrow and intervertebral disc. Monte Carlo N-particle (MCNP4C) was used to model the 90Y and 131I radiation distribution. Images of the CSF compartment were convolved with the radiation distribution to determine the dose within the subarachnoid space and surrounding tissues. 90Y appears to be a suitable radionuclide in the treatment of central nervous system (CNS) malignancies when attached to mAb's and the dose distribution would be confined largely within the vertebral foramen. This choice may offer favourable dose improvement to the subarachnoid and surface of spinal cord over 131I in such an application.

  19. Determination of 90Sr in milk by solvent extraction of 90Y

    International Nuclear Information System (INIS)

    Mitsuhashi, Toshihiko; Sakanoue, Masanobu.

    1977-01-01

    In order to replace the conventional method using violent fuming nitric acid, a new method for the determination of 90 Sr in milk has been developed by using the solvent extraction with bis (2-ethylhexyl) phosphoric acid (HDEHP). The daughter nuclide 90 Y in a radiochemical equilibrium with its parent 90 Sr was extracted with 2:1 HDEHP-toluene from the acid solution (1M HCl) of milk ash sample prepared by dry-ashing. After stripping with 8M HCl, 90 Y, together with stable yttrium added as carrier, was precipitated as oxalate to prepare β-counting source. The radiochemical purity was confirmed by decay curve. The decontamination of strontium was checked by applying non-dispersive fluorescence x-ray analysis using 133 Ba as irradiating source. Bone samples of cow were also analyzed by the same method and the results were compared with those obtained by other methods. The duplicate crosschecking analyses of finely ground bone samples were carried out to examine the effectiveness of this method. This simple new method was found to be very effective for the routine analysis of 90 Sr in these samples. (auth.)

  20. N-m-nitrocinnamoylphenylhydroxyl-amine as reagent for amperometric determination of yttrium

    International Nuclear Information System (INIS)

    Oliferenko, G.L.; Gallaj, Z.A.; Sheina, N.M.; Shvedene, N.V.

    1983-01-01

    Possibility of using organic reagent of unsaturated N-arylsubstituted derivatives class of hydroxamic acids N-m-nitrocinnamoyl phenylhydroxylamire (NCPHA) for amperometric titration of yttrium using indication of e.t.p. by current of reagent oxidation on graphite electrode is investigated. Metal and the NCPHA form difficultly soluble complex with ratio of yttrium to the NCPHA, which is equal to 1:3. Buffer mixtures of 0.1MNH 3 +0.1MCH 3 COOH composis tion with pH 6.3-7.5 are optimal background solutions for amperometric titration of yttrium. The proposed method permits to determine 10-600 μkg of yttrium in the volume of 10 ml. Effect of the series of strange elements on titration of yttrium with NCPHA (Ca, Mg, Mn (2), Al, CU (2), Fe (3) REE and others) is studied. The developed method is used for yttrium determination in luminophores of Casub(n)-- Ysub(m)Fsub(z)xMn(2) (1-10%) composition

  1. Extraction and encapsulation of prodigiosin in chitosan microspheres for targeted drug delivery

    Energy Technology Data Exchange (ETDEWEB)

    Dozie-Nwachukwu, S.O. [Department of Materials Science and Engineering, African University of Science and Technology (AUST) Abuja, Federal Capital Territory (Nigeria); Biotechnology and Genetic Engineering Advanced Laboratory, Sheda Science and Technology Complex (SHESTCO), P.M.B 186, Garki, Abuja, Federal Capital Territory (Nigeria); Danyuo, Y. [Department of Materials Science and Engineering, African University of Science and Technology (AUST) Abuja, Federal Capital Territory (Nigeria); Department of Materials Science and Engineering, Kwara State University, Malete (Nigeria); Obayemi, J.D. [Department of Materials Science and Engineering, African University of Science and Technology (AUST) Abuja, Federal Capital Territory (Nigeria); Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, NJ 08544 (United States); Odusanya, O.S. [Department of Materials Science and Engineering, African University of Science and Technology (AUST) Abuja, Federal Capital Territory (Nigeria); Biotechnology and Genetic Engineering Advanced Laboratory, Sheda Science and Technology Complex (SHESTCO), P.M.B 186, Garki, Abuja, Federal Capital Territory (Nigeria); Malatesta, K. [Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, NJ 08544 (United States); Soboyejo, W.O., E-mail: soboyejo@princeton.edu [Department of Materials Science and Engineering, African University of Science and Technology (AUST) Abuja, Federal Capital Territory (Nigeria); Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, NJ 08544 (United States); Princeton Institute of Science and Technology of Materials (PRISM), Bowen Hall, 70 Prospect Street, Princeton, NJ 08544 (United States)

    2017-02-01

    The encapsulation of drugs in polymeric materials has brought opportunities to the targeted delivery of chemotherapeutic agents. These polymeric delivery systems are capable of maximizing the therapeutic activity, as well as reducing the side effects of anti-cancer agents. Prodigiosin, a secondary metabolite extracted from the bacteria, Serratia marcescens, exhibits anti-cancer properties. Prodigiosin-loaded chitosan microspheres were prepared via water-in-oil (w/o) emulsion technique, using glutaraldehyde as a cross-linker. The morphologies of the microspheres were studied using scanning electron microscopy. The average sizes of the microspheres were between 40 μm and 60 μm, while the percentage yields ranged from 42 ± 2% to 55.5 ± 3%. The resulting encapsulation efficiencies were between 66.7 ± 3% and 90 ± 4%. The in-vitro drug release from the microspheres was characterized by zeroth order, first order and Higuchi and Korsmeyer-Peppas models. - Highlights: • Prodigiosin of ~ 92.8% purity was extracted from locally isolated Serratia marcescens. • This approach reduces the cost and ensure availability of drugs for cancer treatment. • High encapsulation efficiency which increased with increasing drug:polymer ratio • The percentage yield was generally poor due to the recovery process. • Prodigiosin greatly reduced the viability of the breast cancer cell line (MDA-MB-231).

  2. Extraction and encapsulation of prodigiosin in chitosan microspheres for targeted drug delivery

    International Nuclear Information System (INIS)

    Dozie-Nwachukwu, S.O.; Danyuo, Y.; Obayemi, J.D.; Odusanya, O.S.; Malatesta, K.; Soboyejo, W.O.

    2017-01-01

    The encapsulation of drugs in polymeric materials has brought opportunities to the targeted delivery of chemotherapeutic agents. These polymeric delivery systems are capable of maximizing the therapeutic activity, as well as reducing the side effects of anti-cancer agents. Prodigiosin, a secondary metabolite extracted from the bacteria, Serratia marcescens, exhibits anti-cancer properties. Prodigiosin-loaded chitosan microspheres were prepared via water-in-oil (w/o) emulsion technique, using glutaraldehyde as a cross-linker. The morphologies of the microspheres were studied using scanning electron microscopy. The average sizes of the microspheres were between 40 μm and 60 μm, while the percentage yields ranged from 42 ± 2% to 55.5 ± 3%. The resulting encapsulation efficiencies were between 66.7 ± 3% and 90 ± 4%. The in-vitro drug release from the microspheres was characterized by zeroth order, first order and Higuchi and Korsmeyer-Peppas models. - Highlights: • Prodigiosin of ~ 92.8% purity was extracted from locally isolated Serratia marcescens. • This approach reduces the cost and ensure availability of drugs for cancer treatment. • High encapsulation efficiency which increased with increasing drug:polymer ratio • The percentage yield was generally poor due to the recovery process. • Prodigiosin greatly reduced the viability of the breast cancer cell line (MDA-MB-231).

  3. High-power microcavity lasers based on highly erbium-doped sol-gel aluminosilicate glasses

    International Nuclear Information System (INIS)

    Le Ngoc Chung; Chu Thi Thu Ha; Nguyen Thu Trang; Pham Thu Nga; Pham Van Hoi; Bui Van Thien

    2006-01-01

    High-power whispering-gallery-mode (WGM) lasing from highly erbium-doped sol-gel aluminosilicate microsphere cavity coupled to a half-tapered optical fiber is presented. The lasing output power as high as 0.45 mW (-3.5 dBm) was obtained from sol-gel glass microsphere cavity with diameters in the range of 40-150 μm. The sol-gel method for making highly concentration Er-doped aluminosilicate glasses with Er-ion concentrations from 0.125 to 0.65 mol% of Er 3+ is described. Controlling collected lasing wavelength at each WGM is possible by adjusting the distance between the half-taper fiber and the microcavity and by diameter of the waist of half-taper fiber. Using the analytic formulas we calculated the TE and TM lasing modes and it is shown that the experimental results are in good agreement with the calculation prediction

  4. PLGA/alginate composite microspheres for hydrophilic protein delivery

    International Nuclear Information System (INIS)

    Zhai, Peng; Chen, X.B.; Schreyer, David J.

    2015-01-01

    Poly(lactic-co-glycolic acid) (PLGA) microspheres and PLGA/alginate composite microspheres were prepared by a novel double emulsion and solvent evaporation technique and loaded with bovine serum albumin (BSA) or rabbit anti-laminin antibody protein. The addition of alginate and the use of a surfactant during microsphere preparation increased the encapsulation efficiency and reduced the initial burst release of hydrophilic BSA. Confocal laser scanning microcopy (CLSM) of BSA-loaded PLGA/alginate composite microspheres showed that PLGA, alginate, and BSA were distributed throughout the depths of microspheres; no core/shell structure was observed. Scanning electron microscopy revealed that PLGA microspheres erode and degrade more quickly than PLGA/alginate composite microspheres. When loaded with anti-laminin antibody, the function of released antibody was well preserved in both PLGA and PLGA/alginate composite microspheres. The biocompatibility of PLGA and PLGA/alginate microspheres were examined using four types of cultured cell lines, representing different tissue types. Cell survival was variably affected by the inclusion of alginate in composite microspheres, possibly due to the sensitivity of different cell types to excess calcium that may be released from the calcium cross-linked alginate. - Highlights: • A double emulsion technique is used to prepare protein-loaded PLGA or PLGA/alginate microspheres. • PLGA, alginate and protein are distributed evenly within microsphere structure. • Addition of alginate improves loading efficiency and slows degradation and protein release. • PLGA/alginate microspheres have favorable biocompatibility

  5. PLGA/alginate composite microspheres for hydrophilic protein delivery

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Peng [Department of Anatomy and Cell Biology, University of Saskatchewan, S7N5E5 (Canada); Division of Biomedical Engineering, University of Saskatchewan, S7N5A9 (Canada); Chen, X.B. [Department of Mechanical Engineering, University of Saskatchewan, S7N5A9 (Canada); Division of Biomedical Engineering, University of Saskatchewan, S7N5A9 (Canada); Schreyer, David J., E-mail: david.schreyer@usask.ca [Department of Anatomy and Cell Biology, University of Saskatchewan, S7N5E5 (Canada); Division of Biomedical Engineering, University of Saskatchewan, S7N5A9 (Canada)

    2015-11-01

    Poly(lactic-co-glycolic acid) (PLGA) microspheres and PLGA/alginate composite microspheres were prepared by a novel double emulsion and solvent evaporation technique and loaded with bovine serum albumin (BSA) or rabbit anti-laminin antibody protein. The addition of alginate and the use of a surfactant during microsphere preparation increased the encapsulation efficiency and reduced the initial burst release of hydrophilic BSA. Confocal laser scanning microcopy (CLSM) of BSA-loaded PLGA/alginate composite microspheres showed that PLGA, alginate, and BSA were distributed throughout the depths of microspheres; no core/shell structure was observed. Scanning electron microscopy revealed that PLGA microspheres erode and degrade more quickly than PLGA/alginate composite microspheres. When loaded with anti-laminin antibody, the function of released antibody was well preserved in both PLGA and PLGA/alginate composite microspheres. The biocompatibility of PLGA and PLGA/alginate microspheres were examined using four types of cultured cell lines, representing different tissue types. Cell survival was variably affected by the inclusion of alginate in composite microspheres, possibly due to the sensitivity of different cell types to excess calcium that may be released from the calcium cross-linked alginate. - Highlights: • A double emulsion technique is used to prepare protein-loaded PLGA or PLGA/alginate microspheres. • PLGA, alginate and protein are distributed evenly within microsphere structure. • Addition of alginate improves loading efficiency and slows degradation and protein release. • PLGA/alginate microspheres have favorable biocompatibility.

  6. Yttrium doped BSCF membranes for oxygen separation

    DEFF Research Database (Denmark)

    Haworth, P.; Smart, S.; Glasscock, Julie

    2011-01-01

    This work investigates the partial substitution of yttrium in place of iron in BSCF to form Ba0.5Sr0.5Co0.8Fe0.2−xYxO3−δ, where x varied between 0 and 0.2. X-ray diffraction patterns showed the formation of a perovskite cubic phase structure up to x = 0.15, whilst the full substitution of yttrium...

  7. Yttrium and lanthanum recovery from low cerium carbonate, yttrium carbonate and yttrium concentrate; Aproveitamento de itrio e lantanio de um carbonato de terras raras de baixo teor em cerio, de um carbonato de itrio e de um oxido de terras itricas

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcelos, Mari Estela de

    2006-07-01

    In this work, separation, enrichment and purification of lanthanum and yttrium were performed using as raw material a commercial low cerium rare earth concentrate named LCC (low cerium carbonate), an yttrium concentrate named 'yttrium carbonate', and a third concentrated known as 'yttrium earths oxide. The first two were industrially produced by the late NUCLEMON - NUCLEBRAS de Monazita e Associados Ltda, using Brazilian monazite. The 'yttrium earths oxide' come from a process for preparation of lanthanum during the course of the experimental work for the present thesis. The following techniques were used: fractional precipitation with urea; fractional leaching of the LCC using ammonium carbonate; precipitation of rare earth peroxycarbonates starting from the rare earth complex carbonates. Once prepared the enriched rare earth fractions the same were refined using the ion exchange chromatography with strong cationic resin without the use of retention ion and elution using the ammonium salt of ethylenediaminetetraacetic acid. With the association of the above mentioned techniques were obtained pure oxides of yttrium (>97,7%), lanthanum (99,9%), gadolinium (96,6%) and samarium (99,9%). The process here developed has technical and economic viability for the installation of a large scale unity. (author)

  8. Thermoanalytical study of the formation mechanism of yttria from yttrium acetate

    International Nuclear Information System (INIS)

    Farjas, J.; Camps, J.; Roura, P.; Ricart, S.; Puig, T.; Obradors, X.

    2011-01-01

    Highlights: → Thermal decomposition of yttrium acetate: three endothermic stages. → Intermediates: yttrium hydroxide and carbonate. → Product: cubic yttria (the degree of transformation is at least 99%). → The decomposition does not depend on the oxygen partial pressure. - Abstract: The processes involved in the thermal decomposition of yttrium acetate tetrahydrate, Y(CH 3 COO) 3 .4H 2 O, in air and in an inert atmosphere have been analyzed by thermoanalytical techniques (thermogravimetry, differential thermal analysis and evolved gas analysis) and by the structural characterization (X-ray diffraction, infrared spectroscopy, elemental analysis and scanning electron microscopy) of intermediates and final products. Decomposition of yttrium acetate is an endothermic transformation that takes place in a temperature range between 350 and 900 o C. The evolution of the mass during the decomposition process is not affected by the presence of oxygen. The process is initiated by the rupture of the bond between the metallic cation and the acetate ligand. This initial step (350-450 o C) involves the formation of amorphous yttrium hydroxide and yttrium carbonate and is characterized by a fast mass loss rate. A sudden decrease of the mass loss rate indicates a change in the decomposition kinetics that continues with the decomposition of yttrium hydroxide and yttrium carbonate. The main effect of an oxygen atmosphere is an intense exothermic process due to the combustion of organic species in the gas phase.

  9. Interstitial pituitary irradiation with 90Y for the treatment of acromomegaly

    International Nuclear Information System (INIS)

    Cassar, J.; Doyle, F.H.; Banks, L.M.; Jadresic, A.; Mashiter, K.; Joplin, G.F.

    1981-01-01

    The management of 54 acromegalics referred to us between 1974 and 1978 has been analysed. Twenty-two patients were treated with pituitary implants of yttrium-90 ( 90 Y). Eleven are in complete remission (mean growth hormone (GH) < 11 mlU/l), 8 had improved (mean GH 11-20 mlU/l or 50% less than preoperatively) and 3 were poor responders. Two patients had temporary 6th nerve paresis. Seven patients are on replacement therapy. Thirty- one patients were not implanted for the following reasons with a number of patients having more than one: extension of the tumour into the spehnoid sinus 10, or above the sella 3, partially empty sella 9, internal carotids too close to midline 2, invisible landmarks 1, mild acromegaly 6, poor general health 3, declined investigations or operation 6. It is concluded that pituitary implant of yttrium is an effective and safe form of treatment on carefully selected patients. (author)

  10. Separation and Species Characterization of Complex Compound of Yttrium-90 and Strontium-90 by Paper Electrophoresis

    International Nuclear Information System (INIS)

    Sulaiman; Adang Hardi G; Noor Anis Kundari

    2007-01-01

    The research for species characterization of 90 Y and 90 Sr complex compound have been conducted using variation of buffer, concentration of HCl, electrophoresis operation voltage, time of electrophoresis, and electrophoresis migration media. From many trials, the conclusions are the applicable buffer are tartrate buffer and citrate buffer. These buffers can make a complex compound of 90 Y and there is migration to the anode. But, 90 Sr can’t make any complex compound and migration to the cathode. The optimum concentration of hydrochloride acid is 8 M with tartrate buffer but for citrate buffer, the concentration HCl is 2 M. The hydrochloric acid is used to dissolved the both elements as the mentioned above, but also for making complex ligand. The optimum electrophoresis operation voltage is 200 Volt for the both buffer solution and the duration of electrophoresis operation is 2.5 hours with using tartrate buffer but for citrate buffer the duration is 2 hours. The media of migration which can be used for replacing paper is silica. (author)

  11. Temperature influence in crystallinity of polymer microspheres

    International Nuclear Information System (INIS)

    Rezende, Cristiane de P.; Novack, Katia M.

    2011-01-01

    Drug delivery technology is evolving through the creation of new techniques of drug delivery effectively. The new methods used in drugs administration are based in microencapsulation process. Microsphere encapsulation modifies drug delivery bringing benefits and efficiency. In this work has been evaluated the influence of temperature in microspheres preparation. Microspheres were obtained by PMMA-co-PEG (COP) copolymer with indomethacin inserted in polymer matrix. Samples were characterized by SEM, DSC and XRD. SEM micrographs confirmed the formation of different sizes of microspheres and it was verified that higher temperatures make more crystalline microspheres. (author)

  12. Study of quantum dot based on tin/yttrium mixed oxide doped with terbium to be used as biomarker

    International Nuclear Information System (INIS)

    Paganini, Paula P.; Felinto, Maria Claudia F.C.; Kodaira, Claudia A.; Brito, Hermi F.; Nunes, Luiz Antonio O.

    2009-01-01

    Quantum dots (semiconductors nanocrystals) have brought a promising field to develop a new generation of luminescent biomarkers. The use of lanthanides ions as luminescent markers has many advantages, for example a security method, low cost, high specificity and also the luminescence can be promptly measured with high sensibility and accuracy. These luminescent dots are functionalized with biomolecules. For the luminophore particle to be connect with biologicals molecules (for example covalent antibody) is necessary a previous chemical treatment to modify luminophore particle surface and this process is called functionalization. A prior chemical treatment with changes on the surface luminophore particle is necessary to couple the luminophore to biological molecules. This process can be used as coating which can protect these particles from being dissolved by acid as well as provide functional groups for biological conjugation. This work presents a photoluminescence study of nanoparticles based on tin/yttrium mixed oxides doped with terbium (SnO 2 /Y 2 O 3 :Tb 3+ ), synthesized by coprecipitation method. The nanoparticles were submitted to thermal treatment and characterized by X-Ray Powder Diffraction (XRD) that showed cassiterite phase formation and the influence of thermal treatment on nanoparticles structures. These nanoparticles going to be functionalized with a natural polysaccharide (chitosan) in order to form microspheres. These microspheres going to be irradiated with gamma radiation to sterilization and it can be evaluated if the nanoparticles are resistant to irradiation and they do not lose functionality with this process. (author)

  13. Hierarchical Mn2O3 Microspheres In-Situ Coated with Carbon for Supercapacitors with Highly Enhanced Performances

    Science.gov (United States)

    Gong, Feilong; Lu, Shuang; Peng, Lifang; Zhou, Jing; Kong, Jinming; Jia, Dianzeng; Li, Feng

    2017-01-01

    Porous Mn2O3 microspheres have been synthesized and in-situ coated with amorphous carbon to form hierarchical C@Mn2O3 microspheres by first producing MnCO3 microspheres in solvothermal reactions, and then annealing at 500 °C. The self-assembly growth of MnCO3 microspheres can generate hollow structures inside each of the particles, which can act as micro-reservoirs to store biomass-glycerol for generating amorphous carbon onto the surfaces of Mn2O3 nanorods consisting of microspheres. The C@Mn2O3 microspheres, prepared at 500 °C, exhibit highly enhanced pseudocapacitive performances when compared to the particles after annealed at 400 °C and 600 °C. Specifically, the C@Mn2O3 microspheres prepared at 500 °C show high specific capacitances of 383.87 F g−1 at current density of 0.5 A g−1, and excellent cycling stability of 90.47% of its initial value after cycling for 5000 times. The asymmetric supercapacitors assembled with C@Mn2O3 microspheres after annealed at 500 °C and activated carbon (AC) show an energy density of up to 77.8 Wh kg−1 at power density of 500.00 W kg−1, and a maximum power density of 20.14 kW kg−1 at energy density of 46.8 Wh kg−1. We can attribute the enhanced electrochemical performances of the materials to their three-dimensional (3D) hierarchical structure in-situ coated with carbon. PMID:29168756

  14. Hierarchical Mn2O3 Microspheres In-Situ Coated with Carbon for Supercapacitors with Highly Enhanced Performances

    Directory of Open Access Journals (Sweden)

    Feilong Gong

    2017-11-01

    Full Text Available Porous Mn2O3 microspheres have been synthesized and in-situ coated with amorphous carbon to form hierarchical C@Mn2O3 microspheres by first producing MnCO3 microspheres in solvothermal reactions, and then annealing at 500 °C. The self-assembly growth of MnCO3 microspheres can generate hollow structures inside each of the particles, which can act as micro-reservoirs to store biomass-glycerol for generating amorphous carbon onto the surfaces of Mn2O3 nanorods consisting of microspheres. The C@Mn2O3 microspheres, prepared at 500 °C, exhibit highly enhanced pseudocapacitive performances when compared to the particles after annealed at 400 °C and 600 °C. Specifically, the C@Mn2O3 microspheres prepared at 500 °C show high specific capacitances of 383.87 F g−1 at current density of 0.5 A g−1, and excellent cycling stability of 90.47% of its initial value after cycling for 5000 times. The asymmetric supercapacitors assembled with C@Mn2O3 microspheres after annealed at 500 °C and activated carbon (AC show an energy density of up to 77.8 Wh kg−1 at power density of 500.00 W kg−1, and a maximum power density of 20.14 kW kg−1 at energy density of 46.8 Wh kg−1. We can attribute the enhanced electrochemical performances of the materials to their three-dimensional (3D hierarchical structure in-situ coated with carbon.

  15. Studies on yttrium oxide coatings for corrosion protection against molten uranium

    International Nuclear Information System (INIS)

    Chakravarthy, Y.; Bhandari, Subhankar; Pragatheeswaran; Thiyagarajan, T.K.; Ananthapadmanabhan, P.V.; Das, A.K.; Kumar, Jay; Kutty, T.R.G.

    2012-01-01

    Yttrium oxide is resistant to corrosion by molten uranium and its alloys. Yttrium oxide is recommended as a protective oxide layer on graphite and metal components used for melting and processing uranium and its alloys. This paper presents studies on the efficacy of plasma sprayed yttrium oxide coatings for barrier applications against molten uranium

  16. Thermal evolution of structure and photocatalytic activity in polymer microsphere templated TiO{sub 2} microbowls

    Energy Technology Data Exchange (ETDEWEB)

    Erdogan, Deniz Altunoz; Polat, Meryem [Department of Chemistry, Bilkent University, 06800 Ankara (Turkey); Garifullin, Ruslan; Guler, Mustafa O. [Institute of Materials Science and Nanotechnology, National Nanotechnology Research Center (UNAM), Bilkent University, 06800 Ankara (Turkey); Ozensoy, Emrah, E-mail: ozensoy@fen.bilkent.edu.tr [Department of Chemistry, Bilkent University, 06800 Ankara (Turkey)

    2014-07-01

    Polystyrene cross-linked divinyl benzene (PS-co-DVB) microspheres were used as an organic template in order to synthesize photocatalytic TiO{sub 2} microspheres and microbowls. Photocatalytic activity of the microbowl surfaces were demonstrated both in the gas phase via photocatalytic NO(g) oxidation by O{sub 2}(g) as well as in the liquid phase via Rhodamine B degradation. Thermal degradation mechanism of the polymer template and its direct influence on the TiO{sub 2} crystal structure, surface morphology, composition, specific surface area and the gas/liquid phase photocatalytic activity data were discussed in detail. With increasing calcination temperatures, spherical polymer template first undergoes a glass transition, covering the TiO{sub 2} film, followed by the complete decomposition of the organic template to yield TiO{sub 2} exposed microbowl structures. TiO{sub 2} microbowl systems calcined at 600 °C yielded the highest per-site basis photocatalytic activity. Crystallographic and electronic properties of the TiO{sub 2} microsphere surfaces as well as their surface area play a crucial role in their ultimate photocatalytic activity. It was demonstrated that the polymer microsphere templated TiO{sub 2} photocatalysts presented in the current work offer a promising and a versatile synthetic platform for photocatalytic DeNO{sub x} applications for air purification technologies.

  17. Treatment of unresectable hepatocellular carcinoma with intrahepatic yttrium 90 microspheres: a risk-stratification analysis.

    Science.gov (United States)

    Goin, James E; Salem, Riad; Carr, Brian I; Dancey, Janet E; Soulen, Michael C; Geschwind, Jean-Francois H; Goin, Kathleen; Van Buskirk, Mark; Thurston, Kenneth

    2005-02-01

    To present the findings of a risk-stratification survival analysis with use of data collected on a heterogeneous group of patients with hepatocellular carcinoma (HCC) treated with TheraSphere. Baseline, treatment, and follow-up data were collected and analyzed from 121 TheraSphere-treated patients. Survival analyses were performed to identify those variables most strongly associated with 3-month mortality. The presence of any of the identified risk variables resulted in the assignment of a patient to the high-risk category. Five liver reserve and two non-liver reserve variables were identified and used to stratify patients into low- or high-risk groups. Sixteen of the 33 patients assigned to the high-risk group (49%) did not survive the first 3 months after treatment, compared with six of the 88 patients assigned to the low-risk group (7%; Fisher exact test, P TheraSpheres should be evaluated for the presence of the risk variables described herein. The absence of these variables is predictive of improved survival (median of 466 days) compared with patients at high risk (median of 108 days).

  18. Country report: Poland. 1. Determination of {sup 90}Sr in {sup 90}YCL{sub 3} solution using DGA and SR-Spec resins (extraction chromatography) and by TLC according to USP. 2. Preliminary investigation on antibody biotinylation. 3. The development of method for preparation of human albumin microspheres as potential radionuclide carriers for diagnostic and therapeutic use. 4. Preparation of radiocolloids for radiosynovectomy using radionuclides of various beta energies

    Energy Technology Data Exchange (ETDEWEB)

    Pawlak, D.; Mikolajczak, R.; Korsak, A.; Dziel, T.; Parus, J. L.; Byszewska-Szpocinska, E.; Jakubowska, E.; Mikolajczak, R.; Jaroń, A.; Pijarowska, J.; Iller, E.; Mikolajczak, W.

    2010-07-01

    1. • It seems that strontium can be more efficiently eluted for the DGA resin than form the Sr-spec resin. Paper chromatography (USP) method provides good resolution of Y and Sr, more results are needed to evaluate results statistically. Comparison of paper chromatography (USP) with paper extraction chromatography was not possible due to the problems in purchasing of the KSM-17. Further works in order to determine detection and determination limits of each of proposed methods are planned. 2. • The preliminary investigation on antibody biotinylation has been performed using commercially available polyclonal human immunoglobulin IgG, mw 150 kDa (Biomed Sp.z o.o, Lublin). Sulfo-NHS –Biotin (Pierce Biotechnology) was used as biotinylating agent. Activated biotin as sulfosuccinimidyl-6-[biotin-amido]hexanoate. is one of the commonly used reagent for proteins biotinylation. Sulfo-NHS-biotin effectively reacts at pH 7-9 with primary amino groups (- NH2) of proteins provided by lysine residues and Nterminus of polypeptide, forming stable amide bond. This reagent dissolves well in water. 3. • The average production yield of HAM for receiving the desired size range between 10-32 μm amounts to 84% and the mean size of particles was estimated to about 15 μm. Optical micrographs show microspheres as very regular spherical forms with quite smooth surfaces and rather narrow spread of size in the selected range. The labelling yields determined as relation of measured radioactivity remaining in the membrane filter to the total radioactivity were > 95% for 99mTc-HAM complex and > 98% for 90Y–X-HAM and 177Lu-X-HAM complexes. Labelled modified microspheres showed high in vitro stability in human plasma with only 4-5% loss of radioactivity from the surface after 48 h of incubation. 4. • The aim of the project is synthesis of monodispersive particles of yttrium citrate and characterization of its surface with instrumental techniques (collaboration with Maria Curie

  19. Analyses and quantitative determination of the strontium radioisotopes 89 and 90 in milk powder; Recherche et dosage des isotopes radioactifs 89 et 90 du strontium dans le lait en poudre

    Energy Technology Data Exchange (ETDEWEB)

    Jeanmaire, L; Michon, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    The authors describe a procedure for the determination of the strontium radioisotopes 89 and 90. The concentration of strontium is made possible by the insolubility of its nitrate salt in strong nitric acid which allows the removal of greatest part of calcium. The purification is performed on a cation exchange column. The amount of radioisotope 90 is determined by means of its daughter product yttrium 90 necessary calibrations and computations are treated in special paragraphs. With regard to the reproducibility of the measurements, the fluctuations are less than 20 per cent. This seems satisfaction for such a technique which have great sensibility while being long and necessitative great carefulness. (author) [French] Les auteurs decrivent une technique de dosage des isotopes 89 et 90 du strontium. La concentration du strontium est assuree grace a l'insolubilite de son nitrate dans l'acide nitrique concentre, ce qui permet d'eliminer la plus grande partie du Ca. La purification se fait sur une colonne echangeuse de cations. L'isotope 90 est dose grace a son descendant l'yttrium 90. Les etalonnages et calculs necessaires font l'objet de paragraphes detailles. En ce qui concerne la reproductibilite des mesures, les fluctuations sont inferieures a 20 pour cent, ce qui semble satisfaisant devant la grande sensibilite de la methode qui reste cependant longue et delicate. (auteur)

  20. A novel route for synthesis and growth formation of metal oxides microspheres: Insights from V_2O_3 microspheres

    International Nuclear Information System (INIS)

    Zhang, Yifu; Huang, Chi; Meng, Changgong; Hu, Tao

    2016-01-01

    Highly polydisperse V_2O_3 solid microspheres with large specific surface area were successfully synthesized via a facile hydrothermal decomposition of VOC_2O_4 solution. The morphology and composition were characterized by scanning electron microscopy (SEM), Energy dispersive spectrometer (EDS), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). V_2O_3 microspheres display an obvious Mott phase transition at −128.5 °C (cooling curve) and −114.5 °C (heating curve). Some parameters including the reaction temperature, concentration of VOC_2O_4, reaction time, surfactant, H_2C_2O_4 and precursor were briefly discussed to reveal the formation of V_2O_3 microspheres. It was found that the precursor is crucial for the fabrication of microsphere. A self-assembly growth mechanism was suggested to explain the growth process of microspheres and the autogenic CO and CO_2 gas served as the soft templates. Furthermore, this route was developed to synthesize different metal oxides microspheres, and it was found that AlO(OH), Fe_3O_4, Fe_2O_3, Co_3O_4, Cr_2O_3, MoO_2 and WO_3 microspheres were obtained. All the results showed this process was successfully explored as a methodology to synthesize different metal oxides microspheres using the gas as the templates by this facile hydrothermal route. - Highlights: • Highly uniform V_2O_3 solid microspheres were synthesized. • V_2O_3 microspheres display an obvious Mott phase transition. • The autogenic CO and CO_2 gas served as the soft templates for designed synthesis. • AlO(OH), Fe_3O_4, Fe_2O_3, Co_3O_4, Cr_2O_3, MoO_2 and WO_3 microspheres were obtained. • A methodology to synthesize different metal oxides microspheres was developed.

  1. Magnetic susceptibility characterisation of superparamagnetic microspheres

    Science.gov (United States)

    Grob, David Tim; Wise, Naomi; Oduwole, Olayinka; Sheard, Steve

    2018-04-01

    The separation of magnetic materials in microsystems using magnetophoresis has increased in popularity. The wide variety and availability of magnetic beads has fuelled this drive. It is important to know the magnetic characteristics of the microspheres in order to accurately use them in separation processes integrated on a lab-on-a-chip device. To investigate the magnetic susceptibility of magnetic microspheres, the magnetic responsiveness of three types of Dynabeads microspheres were tested using two different approaches. The magnetophoretic mobility of individual microspheres is studied using a particle tracking system and the magnetization of each type of Dynabeads microsphere is measured using SQUID relaxometry. The magnetic beads' susceptibility is obtained at four different applied magnetic fields in the range of 38-70 mT for both the mobility and SQUID measurements. The susceptibility values in both approaches show a consistent magnetic field dependence.

  2. Air annealing induced transformation of cubic CdSe microspheres into hexagonal nanorods and micro-pyramids

    Energy Technology Data Exchange (ETDEWEB)

    Kale, Rohidas B., E-mail: rb_kale@yahoo.co.in [Department of Physics, Institute of Science, Mumbai 400032, M.S. (India); Lu, Shih-Yuan, E-mail: sylu@mx.nthu.edu.tw [Department of Chemical Engineering, National Tsing-Hua University, Hsin-Chu 30013, Taiwan (China)

    2015-08-15

    Highlights: • Nanocrystalline CdSe thin films were deposited using inexpensive CBD method. • Air annealing induced structural and interesting morphological transformation. • The as-deposited CdSe thin films showed a blue shift in its optical spectra. • The films showed a red shift in their optical spectra after annealing. - Abstract: CdSe thin films have been deposited onto glass substrates using a chemical bath deposition method at relatively low temperatures (40 °C). The precursors used for the deposition of the thin films are cadmium nitrate hexahydrate, freshly prepared sodium selenosulfate solution and aqueous ammonia solution as a complex as well as pH adjusting reagent. In order to study the influence of air annealing on their physicochemical properties, the as-deposited CdSe thin films were further annealed at 200 °C and 400 °C for 3 h in air atmosphere. Significant changes in the morphology and photonic properties were clearly observed after the thermal annealing of the CdSe thin films. The as-deposited CdSe films grow with the cubic phase that transforms into mixed cubic and hexagonal wurtzite phase with improved crystalline quality of the films after the air annealing. Morphological observation reveals that the as-deposited thin films grow with multilayer that consists of network or mesh like structure, uniformly deposited on the glass substrate over which microspheres are uniformly distributed. After air annealing, CdSe nanorods emerged from the microspheres along with conversion of few microspheres into micro-pyramids. The UV–visible study illustrates that the as-deposited thin film shows blue shifts in its optical spectrum and the spectrum was red-shifted after annealing the CdSe thin films. The band gap of the CdSe thin films were found to be decreased after the thermal treatment.

  3. Method for sizing hollow microspheres

    Science.gov (United States)

    Farnum, E.H.; Fries, R.J.

    1975-10-29

    Hollow Microspheres may be effectively sized by placing them beneath a screen stack completely immersed in an ultrasonic bath containing a liquid having a density at which the microspheres float and ultrasonically agitating the bath.

  4. Thermal decomposition of yttrium(III) propionate and butyrate

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude

    2013-01-01

    The thermal decompositions of yttrium(III) propionate monohydrate (Y(C2H5CO2)3·H2O) and yttrium(III) butyrate dihydrate (Y(C3H7CO2)3·2H2O) were studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction and hot-stage microscopy. These two...

  5. Preparation and characterization of sol-gel derived (Th{sub x}Ce{sub 1-x})O{sub 2} microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Cetinkaya, Berkan; Tel, Hueseyin [Ege Univ., Izmir (Turkey). Inst. of Nuclear Sciences

    2018-04-01

    (Th{sub x}Ce{sub 1-x})O{sub 2} microspheres (x = 0.50, 0.75 and 0.95) with high homogeneity were prepared via sol-gel technique, starting from the initial chemical materials Th(NO{sub 3}){sub 4} . 5H{sub 2}O and (NH{sub 4}){sub 2}[Ce(NO{sub 3}){sub 6}]. The sols were prepared by addition of ammonia under pH and temperature control. Sols were gelated to spherical form in a gelation system consisting of peristaltic pump, flow regulator, nozzle and a glass column. To obtain crack-free spheres suitable for gelation, source sols neutralization conditions, drop formation and pre-hardening medium were investigated and the optimum conditions were determined. After aging, washing and drying steps, gel microspheres were characterized. For this purpose, thermal behaviors of spheres were investigated with TG/DTA analysis. Dried microspheres at 80 C were calcined at three different temperatures, namely 450 C, 800 C and 1150 C, and crystal parameters were calculated from XRD data. BET specific surface area and BJH porosity analyses were also carried out.

  6. Dosage of strontium 90 in human bone ashes; Dosage du strontium 90 sans les cendres d'os humain

    Energy Technology Data Exchange (ETDEWEB)

    Patti, F; Jeanmaire, L [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The determination of {sup 90}Sr in bones by dosage of its daughter product {sup 90}Y is a 4-step process: 1) elimination of the phosphate ions by precipitation of the Ca and Sr as oxalate in the presence of acid; 2) reduction in the calcium concentration to a suitable level by the addition of a known volume of nitric acid (a single precipitation is sufficient), the precipitation yield of the strontium nitrate is checked by the measurement of the amount of {sup 85}Sr added as tracer; 3) purification by a yttrium hydroxide precipitation; 4) extraction at equilibrium of the {sup 90}Y which is counted to give the concentration. By using 50 gm of ash it is possible to detect about 0.1 pCi of {sup 90}Sr per gram of calcium. The advantages of this technique: -) treatment of a large quantity of bone ash -) the use of a small volume of nitric acid (less than 2 ml/g of ash, and -) the various operations present no difficulty. (authors) [French] Determination du Sr dans les os par dosage de son produit de filiation {sup 90}Y. Principe du dosage: 1 - Eliminer les ions phosphates par precipitation du calcium et du strontium sous forme d'oxalate en milieu acide. 2 - Reduire la concentration en calcium a un niveau convenable par addition d'un volume determine d'acide nitrique (une seule precipitation est necessaire). Le rendement de precipitation du nitrate de strontium est controle par la mesure de {sup 85}Sr ajoute comme traceur. 3 - Purifier par une precipitation d'hydroxyde d'yttrium. 4 - Extraire a l'equilibre l'{sup 90}Y qui eat compte pour determiner le {sup 90}Sr. En traitant 50 g de cendre, il est possible de deceler de l'ordre de 0,1 pCi de {sup 90}Sr par gramme de calcium. Les 3 avantages de cette technique: 1 - traitement d'une quantite importante de cendres d'os, 2 - emploi d'un faible volume d'acide nitrique (moins de 2 ml/g de cendres), et 3 - les diverses operations ne presentent aucune difficulte.

  7. Solvent extraction studies on separation of yttrium from xenotime

    International Nuclear Information System (INIS)

    Singh, D.K.; Anitha, M.; Kain, V.

    2017-01-01

    Rare earths consists a group of 15 element from La to Lu in the periodic table and it also includes Sc and Y since they tend to occur in the same ore deposits as the lanthanides and exhibit similar chemical properties. The unique physical-chemical properties of the REEs render them important in applications as varies as high strength magnets, lighting phosphors, policing compounds and ceramics. In particular, yttrium finds numerous applications in many areas including superconductors, lasers, phosphors, nuclear reactors, astronavigation, ceramics etc. Yttrium is chemically similar to heavy rare earths (HRE: terbium, dysprosium, erbium, holmium, ytterbium, thulium and lutecium). Yttrium behaves like HRE due to similarity in ionic radius and finds place between Ho and Er. The cross current profile in terms of the plot of concentration of yttrium in raffinate as a function of contact number indicated the complete recovery of rare earths from nitrate solution of xenotime wet cake

  8. In vitro evaluation of biodegradable microspheres with surface-bound ligands.

    Science.gov (United States)

    Keegan, Mark E; Royce, Sara M; Fahmy, Tarek; Saltzman, W Mark

    2006-02-21

    Protein ligands were conjugated to the surface of biodegradable microspheres. These microsphere-ligand conjugates were then used in two in vitro model systems to evaluate the effect of conjugated ligands on microsphere behavior. Microsphere retention in agarose columns was increased by ligands on the microsphere surface specific for receptors on the agarose matrix. In another experiment, conjugating the lectin Ulex europaeus agglutinin 1 to the microsphere surface increased microsphere adhesion to Caco-2 monolayers compared to control microspheres. This increase in microsphere adhesion was negated by co-administration of l-fucose, indicating that the increase in adhesion is due to specific interaction of the ligand with carbohydrate receptors on the cell surface. These results demonstrate that the ligands conjugated to the microspheres maintain their receptor binding activity and are present on the microsphere surface at a density sufficient to target the microspheres to both monolayers and three-dimensional matrices bearing complementary receptors.

  9. Determination of /sup 90/Sr in milk by solvent extraction of /sup 90/Y

    Energy Technology Data Exchange (ETDEWEB)

    Mitsuhashi, T [National Inst. of Animal Industry, Chiba (Japan); Sakanoue, M

    1977-10-01

    In order to replace the conventional method using violent fuming nitric acid, a new method for the determination of /sup 90/Sr in milk has been developed by using the solvent extraction with bis (2-ethylhexyl) phosphoric acid (HDEHP). The daughter nuclide /sup 90/Y in a radiochemical equilibrium with its parent /sup 90/Sr was extracted with 2:1 HDEHP-toluene from the acid solution (1M HCl) of milk ash sample prepared by dry-ashing. After stripping with 8M HCl, /sup 90/Y, together with stable yttrium added as carrier, was precipitated as oxalate to prepare ..beta..-counting source. The radiochemical purity was confirmed by decay curve. The decontamination of strontium was checked by applying non-dispersive fluorescence x-ray analysis using /sup 133/Ba as irradiating source. Bone samples of cow were also analyzed by the same method and the results were compared with those obtained by other methods. The duplicate crosschecking analyses of finely ground bone samples were carried out to examine the effectiveness of this method. This simple new method was found to be very effective for the routine analysis of /sup 90/Sr in these samples.

  10. A thermal neutron scattering law for yttrium hydride

    Science.gov (United States)

    Zerkle, Michael; Holmes, Jesse

    2017-09-01

    Yttrium hydride (YH2) is of interest as a high temperature moderator material because of its superior ability to retain hydrogen at elevated temperatures. Thermal neutron scattering laws for hydrogen bound in yttrium hydride (H-YH2) and yttrium bound in yttrium hydride (Y-YH2) prepared using the ab initio approach are presented. Density functional theory, incorporating the generalized gradient approximation (GGA) for the exchange-correlation energy, is used to simulate the face-centered cubic structure of YH2 and calculate the interatomic Hellmann-Feynman forces for a 2 × 2 × 2 supercell containing 96 atoms. Lattice dynamics calculations using PHONON are then used to determine the phonon dispersion relations and density of states. The calculated phonon density of states for H and Y in YH2 are used to prepare H-YH2 and Y-YH2 thermal scattering laws using the LEAPR module of NJOY2012. Analysis of the resulting integral and differential scattering cross sections demonstrates adequate resolution of the S(α,β) function. Comparison of experimental lattice constant, heat capacity, inelastic neutron scattering spectra and total scattering cross section measurements to calculated values are used to validate the thermal scattering laws.

  11. Catalyst-free combined synthesis of Zn/ZnO core/shell hollow microspheres and metallic Zn microparticles by thermal evaporation and condensation route

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Waheed S. [Research Centre of Materials Science, Beijing Institute of Technology, Beijing 100081 (China); Cao Chuanbao, E-mail: cbcao@bit.edu.c [Research Centre of Materials Science, Beijing Institute of Technology, Beijing 100081 (China); Nabi, Ghulam; Yao Ruimin; Bhatti, Sajjad H. [Research Centre of Materials Science, Beijing Institute of Technology, Beijing 100081 (China)

    2010-09-17

    Research highlights: {yields} Catalyst-free combined synthesis of metal/semiconductor Zn/ZnO core/shell microspheres with hollow interiors on Si substrate and metallic Zn polygonal microparticles on glass substrate in a single experiment via thermal evaporation and condensation technique was reported. The Zn/ZnO hollow microspheres were observed to have dimensions in the range of 70-80 {mu}m whereas metallic Zn microparticles with polygonal cross section and oblate spherical shape were found to be of 8-10 {mu}m. Some of the Zn/ZnO core/shell hollow spheres were also observed to have single crystalline ZnO pointed rods in extremely low density grown on the outer shell. A vapor-liquid-solid (VLS) process based growth mechanism was proposed for the formation of Zn/ZnO core/shell microspheres with hollow interior. The optical properties of Zn/ZnO core/shell microspheres were investigated by measuring the photoluminescence (PL) spectra at room temperature (RT). Two very strong emission bands were observed at 373 and 469 nm in the ultraviolet and visible regions respectively under excitation wavelength of 325 nm. Also the effect of the various excitation wavelengths on the PL behaviour was studied at room temperature. PL studies of Zn/ZnO core/shell microspheres show the promise of the material for applications in UV and blue light optical devices. - Abstract: Here we report catalyst-free combined synthesis of metal/semiconductor Zn/ZnO core/shell microspheres with hollow interiors on Si substrate and metallic Zn polygonal microparticles on glass substrate in a single experiment via thermal evaporation and condensation technique using nitrogen (N{sub 2}) as carrier agent at 800 {sup o}C for 120 min. The Zn/ZnO hollow microspheres were observed to have dimensions in the range of 70-80 {mu}m whereas metallic Zn microparticles with polygonal cross section and oblate spherical shape were found to be of 8-10 {mu}m. Some of the Zn/ZnO core/shell hollow spheres were also

  12. {sup 90}Y Production and Its Biodistribution in Mice; Pembuatan {sup 90}Y dan Biodistribusinya ke Mencit

    Energy Technology Data Exchange (ETDEWEB)

    Tri-Murni,; Cahyana,; Triyanto,; Djoharly,; Abidin,; Dede-K,; Karyadi, [Center for Development of Radioisotope and Radiopharmacentical(Indonesia)

    2001-11-15

    Yttrium - 90 is radioisotope emitting pure {beta} with maximum energy of 2.27 MeV while its average {beta} energy is 0.93 MeV. {sup 90}Y radioisotope was produced utilizing G.A Siwabessy reactor employing thermal neutron capture process. In nuclear medicine this radioisotope is utilized for bone mettastase palliative and curative therapies. Parameters in this research were the weight of natural Y{sub 2}O{sub 3} target, irradiation time in the reactor, radiochemical purity and specific activity. The end product of the process is YCl{sub 3}, in saline solution. Then sterility of the {sup 90}Y radioisotope so produced is tested and its biodistribution analysis results in mice organs show that the percentage of this radioisotope in the liver is much higher than the ones in heart, kidneys, lung and intestine. Therefore it is concluded that {sup 90}Y radioisotope in the form of YCl{sub 3} can be utilized as a radiopharmaceutical in nuclear medicine. (author)

  13. Intestinal absorption of PLAGA microspheres in the rat.

    Science.gov (United States)

    Damgé, C; Aprahamian, M; Marchais, H; Benoit, J P; Pinget, M

    1996-12-01

    Rhodamine B-labelled poly (DL-lactide-co-glycolide) (PLAGA) microspheres of 2 different sizes, 1-5 microns and 5-10 microns, were administered as a single dose (1.44 x 10(9) and 1.83 x 10(8) particles, respectively) into the ileal lumen of adult rats. The content of rhodamine in the mesenteric vein and ileal lumen was analysed periodically from 10 min to 48 h as well as the distribution of microspheres in the intestinal mucosa and various other tissues. The concentration of rhodamine decreased progressively in the intestinal lumen and was negligible after 24 h. The number of microspheres in the mesenteric vein increased rapidly and reached a maximum after 4 h whatever the size of the particles. It then decreased progressively, but more rapidly with microspheres > 5 microns than with microspheres PLAGA microspheres mainly crossed the intestinal mucosa at the site of Peyer's patches where microspheres of 5 microns were retained in the ileal lumen. A few small microspheres were occasionally observed in the epithelial cells. Only the smallest particles were recovered in the liver, lymph nodes and spleen while basement membranes were always labelled. It is concluded that PLAGA microspheres could be useful for the oral delivery of antigens if their size is between 1 and 5 microns.

  14. Size-dependent cytotoxicity of yttrium oxide nanoparticles on primary osteoblasts in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Guoqiang, E-mail: zhougq1982@163.com; Li, Yunfei; Ma, Yanyan; Liu, Zhu; Cao, Lili; Wang, Da; Liu, Sudan; Xu, Wenshi; Wang, Wenying [Hebei University, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, Key Laboratory of Chemical Biology of Hebei Province, College of Chemistry and Environmental Science (China)

    2016-05-15

    Yttrium oxide nanoparticles are an excellent host material for the rare earth metals and have high luminescence efficiency providing a potential application in photodynamic therapy and biological imaging. In this study, the effects of yttrium oxide nanoparticles with four different sizes were investigated using primary osteoblasts in vitro. The results demonstrated that the cytotoxicity generated by yttrium oxide nanoparticles depended on the particle size, and smaller particles possessed higher toxicological effects. For the purpose to elucidate the relationship between reactive oxygen species generation and cell damage, cytomembrane integrity, intracellular reactive oxygen species level, mitochondrial membrane potential, cell apoptosis rate, and activity of caspase-3 in cells were then measured. Increased reactive oxygen species level was also observed in a size-dependent way. Thus, our data demonstrated that exposure to yttrium oxide nanoparticles resulted in a size-dependent cytotoxicity in cultured primary osteoblasts, and reactive oxygen species generation should be one possible damage pathway for the toxicological effects produced by yttrium oxide particles. The results may provide useful information for more rational applications of yttrium oxide nanoparticles in the future.

  15. Gastroretentive Floating Microspheres of Silymarin: Preparation and ...

    African Journals Online (AJOL)

    Methods: Cellulose microspheres – formulated with hydroxylpropyl methylcellulose (HPMC) and ethyl cellulose (EC) – and Eudragit microspheres – formulated with Eudragit® S 100 (ES) and Eudragit® RL (ERL) - were prepared by an emulsion-solvent evaporation method. The floating microspheres were evaluated for flow ...

  16. A method for determination of Sr-90 Y-90 by using EDTA and ion-exchangers-Applications to the determination of those radioisotopes in milk

    International Nuclear Information System (INIS)

    Silva, C.M.; Lima, F.W. de.

    1987-05-01

    Amethod in which the complex of ethylenediaminetetraacetic acid (EDTA) with yttrium, used in conjunction with ion-exchangers for determination of Sr-90 is described. The method was to the determination of concentration of Sr-90 in milk, avoiding, in this way, protein elimination by acid precipitation or by evaporation of milk and ashing the residue. Analysis of samples of milk from various places in the state of Sao Pa ulo, Brazil, were carried out and the results are reported. Values found are much lower than maximum permissible concentration. (Author) [pt

  17. Development of 2024 AA-Yttrium composites by Spark Plasma Sintering

    Science.gov (United States)

    Vidyasagar, CH S.; Karunakar, D. B.

    2018-04-01

    The method of fabrication of MMNCs is quite a challenge, which includes advanced processing techniques like Spark Plasma Sintering (SPS), etc. The objective of the present work is to fabricate aluminium based MMNCs with the addition of small amounts of yttrium using Spark Plasma Sintering and to evaluate their mechanical and microstructure properties. Samples of 2024 AA with yttrium ranging from 0.1% to 0.5 wt% are fabricated by Spark Plasma Sintering (SPS). Hardness of the samples is determined using Vickers hardness testing machine. The metallurgical characterization of the samples is evaluated by Optical Microscopy (OM), Field Emission Scanning Electron Microscopy (FE-SEM). Unreinforced 2024 AA sample is also fabricated as a benchmark to compare its properties with those of the composite developed. It is found that the yttrium addition increases the above mentioned properties by altering the precipitation kinetics and intermetallic formation to some extent and then decreases gradually when yttrium wt% increases beyond 0.3 wt%. High density (˂ 99.75) is achieved in the samples and highest hardness achieved is 114 Hv, fabricated by spark plasma sintering and uniform distribution of yttrium is observed.

  18. Quantitation in PET using isotopes emitting prompt single gammas: application to yttrium-86

    International Nuclear Information System (INIS)

    Walrand, Stephan; Jamar, Francois; Mathieu, Isabelle; De Camps, Joelle; Lonneux, Max; Pauwels, Stanislas; Sibomana, Merence; Labar, Daniel; Michel, Christian

    2003-01-01

    Several yttrium-90 labelled somatostatin analogues are now available for cancer radiotherapy. After injection, a large amount of the compound is excreted via the urinary tract, while a variable part is trapped in the tumour(s), allowing the curative effect. Unfortunately, the compound may also be trapped in critical tissues such as kidney or bone marrow. As a consequence, a method for assessment of individual biodistribution and pharmacokinetics is required to predict the maximum dose that can be safely injected into patients. However, 90 Y, a pure β - particle emitter, cannot be used for quantitative imaging. Yttrium-86 is a positron emitter that allows imaging of tissue uptake using a PET camera. In addition to the positron, 86 Y also emits a multitude of prompt single γ-rays, leading to significant overestimation of uptake when using classical reconstruction methods. We propose a patient-dependent correction method based on sinogram tail fitting using an 86 Y point spread function library. When applied to abdominal phantom acquisition data, the proposed correction method significantly improved the accuracy of the quantification: the initial overestimation of background activity by 117% was reduced to 9%, while the initial error in respect of kidney uptake by 84% was reduced to 5%. In patient studies, the mean discrepancy between PET total body activity and the activity expected from urinary collections was reduced from 92% to 7%, showing the benefit of the proposed correction method. (orig.)

  19. Sol gel synthesis for preparation of yttrium aluminium garnet

    NARCIS (Netherlands)

    Vrolijk, J.W.G.A.; Willems, J.W.M.M.; Metselaar, R.; With, de G.; Terpstra, R.A.; Metselaar, R.

    1989-01-01

    Sol-gel—synthesis for preparation of pure yttrium aluminium garnet powder with small grain size is subject of this ongoing study. Starting materials were sulfates and chlorides of yttrium and aluminium. To obtain pure YAG (Y3A1SO1Z) pH during hydrolysis as well as temperature during calcination and

  20. Characterizing the residual glass in a MgO/Al2O3/SiO2/ZrO2/Y2O3 glass-ceramic

    Science.gov (United States)

    Seidel, Sabrina; Patzig, Christian; Wisniewski, Wolfgang; Gawronski, Antje; Hu, Yongfeng; Höche, Thomas; Rüssel, Christian

    2016-01-01

    The non-isochemical crystallization of glasses leads to glass-ceramics in which the chemical composition of the amorphous matrix differs from that of the parent glass. It is challenging to solely analyse the properties of these residual glassy phases because they frequently contain finely dispersed crystals. In this study, the composition of the residual glass matrix after the crystallization of a glass with the mol% composition 50.6 SiO2 · 20.7 MgO · 20.7 Al2O3 · 5.6 ZrO2 · 2.4 Y2O3 is analysed by scanning transmission electron microscopy (STEM) including energy dispersive X-ray analysis (EDXS). A batch of the residual glass with the determined composition is subsequently melted and selected properties are analysed. Furthermore, the crystallization behaviour of this residual glass is studied by X-ray diffraction, scanning electron microscopy including electron backscatter diffraction and STEM-EDXS analyses. The residual glass shows sole surface crystallization of indialite and multiple yttrium silicates while bulk nucleation does not occur. This is in contrast to the crystallization behaviour of the parent glass, in which a predominant bulk nucleation of spinel and ZrO2 is observed. The crystallization of the residual glass probably leads to different crystalline phases when it is in contact to air, rather than when it is enclosed within the microstructure of the parent glass-ceramics. PMID:27734918

  1. Autoadaptive Emailtest AZ90 for corrosion monitoring of glass-lined reactors

    International Nuclear Information System (INIS)

    Jean-Marie, H.

    1993-01-01

    In the Chemical and Pharmaceutical Industry, glass-lined vessels often contain very corrosive and harmful products. To prevent major problems such as batch contamination, leakages or explosions, it is important to detect as soon as possible a failure of the glass-lining. The well-known electrolytic method of detection has been improved by using a permanent comparison of a reference current passing between these electrodes and a defect in the glass-lining. This is made possible with the microprocessorized glass-guard to detect a leak rate independent of the product conductivity, to be self monitoring and to give an evaluation of the conductivity

  2. Evaluation of Mechanical Properties of Glass Fiber Posts Subjected to Laser Surface Treatments.

    Science.gov (United States)

    Barbosa Siqueira, Carolina; Spadini de Faria, Natália; Raucci-Neto, Walter; Colucci, Vivian; Alves Gomes, Erica

    2016-10-01

    The aim of this study was to evaluate the influence of laser irradiation on flexural strength, elastic modulus, and surface roughness and morphology of glass fiber posts (GFPs). Laser treatment of GFPs has been introduced to improve its adhesion properties. A total of 40 GFPs were divided into 4 groups according to the irradiation protocol: GC-no irradiation, GYAG-irradiation with erbium:yttrium-aluminum-garnet [Er:YAG], GCR-irradiation with erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG), and GDI-irradiation with diode laser. The GFP roughness and morphology were evaluated through laser confocal microscopy before and after surface treatment. Three-point bending flexural test measured flexural strength and elastic modulus. Data about elastic modulus and flexural strength were subjected to one-way ANOVA and Bonferroni test (p properties of GFPs.

  3. Microsphere estimates of blood flow: Methodological considerations

    International Nuclear Information System (INIS)

    von Ritter, C.; Hinder, R.A.; Womack, W.; Bauerfeind, P.; Fimmel, C.J.; Kvietys, P.R.; Granger, D.N.; Blum, A.L.

    1988-01-01

    The microsphere technique is a standard method for measuring blood flow in experimental animals. Sporadic reports have appeared outlining the limitations of this method. In this study the authors have systematically assessed the effect of blood withdrawals for reference sampling, microsphere numbers, and anesthesia on blood flow estimates using radioactive microspheres in dogs. Experiments were performed on 18 conscious and 12 anesthetized dogs. Four blood flow estimates were performed over 120 min using 1 x 10 6 microspheres each time. The effects of excessive numbers of microspheres pentobarbital sodium anesthesia, and replacement of volume loss for reference samples with dextran 70 were assessed. In both conscious and anesthetized dogs a progressive decrease in gastric mucosal blood flow and cardiac output was observed over 120 min. This was also observed in the pancreas in conscious dogs. The major factor responsible for these changes was the volume loss due to the reference sample withdrawals. Replacement of the withdrawn blood with dextran 70 led to stable blood flows to all organs. The injection of excessive numbers of microspheres did not modify hemodynamics to a greater extent than did the injection of 4 million microspheres. Anesthesia exerted no influence on blood flow other than raising coronary flow. The authors conclude that although blood flow to the gastric mucosa and the pancreas is sensitive to the minor hemodynamic changes associated with the microsphere technique, replacement of volume loss for reference samples ensures stable blood flow to all organs over a 120-min period

  4. Microsphere based improved sunscreen formulation of ethylhexyl methoxycinnamate.

    Science.gov (United States)

    Gogna, Deepak; Jain, Sunil K; Yadav, Awesh K; Agrawal, G P

    2007-04-01

    Polymethylmethacrylate (PMMA) microspheres of ethylhexyl methoxycinnamate (EHM) were prepared by emulsion solvent evaporation method to improve its photostability and effectiveness as sunscreening agent. Process parameters like stirring speed and aqueous polyvinyl alcohol (PVA) concentration were analyzed in order to optimize the formulations. Shape and surface morphology of the microspheres were examined using scanning electron microscopy. Particle size of the microspheres was determined using laser diffraction particle size analyzer. The PMMA microspheres of EHM were incorporated in water-removable cream base. The in vitro drug release of EHM in pH 7.4 was performed using dialysis membrane. Thin layer chromatography was performed to determine photostability of EHM inside the microspheres. The formulations were evaluated for sun protection factor (SPF) and minimum erythema dose (MED) in albino rats. Cream base formulation containing microspheres prepared using EHM:PMMA in ratio of 1:3 (C(3)) showed slowest drug (EHM) release and those prepared with EHM: PMMA in ratio of 1:1 showed fastest release. The cream base formulations containing EHM loaded microspheres had shown better SPF (more than 16.0) as compared to formulation C(d) that contained 3% free EHM as sunscreen agent and showed SPF 4.66. These studies revealed that the incorporation of EHM loaded PMMA microspheres into cream base had greatly increased the efficacy of sunscreen formulation approximately four times. Further, photostability was also shown to be improved in PMMA microspheres.

  5. Preparation and Characterization of Sugar Cane Wax Microspheres ...

    African Journals Online (AJOL)

    ... and characterize indomethacin (IM) microspheres prepared with sugar cane wax microsperes. Methods: Microspheres were prepared by melt-emulsified dispersion and cooling-induced solidification method. The microspheres were characterized by scanning electron microscopy (SEM) and differntial scanning calorimetry ...

  6. Preparation of mesoporous zirconia microspheres as inert matrix

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Ting [State Key Laboratory of New Ceramics and Fine Processing, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China); Wang, Chen; Lv, Jinlong [Beijing Key Laboratory of Fine Ceramics, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China); Liang, Tongxiang, E-mail: txliang@tsinghua.edu.cn [State Key Laboratory of New Ceramics and Fine Processing, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China)

    2016-12-01

    Mesoporous zirconia microspheres, with a diameter of 900 μm, were prepared as an inert accelerator driven system (ADS) transmutation element matrix by the sol-gel method. The purpose of mesopores is to improve the adsorption capacity of inert matrix fuel (IMF) for minor actinides. The study indicated that the mesoporous zirconia performance was improved after the microspheres were hydrothermally treated at 150 °C, the specific surface area increased from 28.29 m{sup 2}/g to 61.28 m{sup 2}/g, and hydrothermal treatment avoided the cracking of the microspheres. Pre-decomposition of the organics during the hydrothermal process stabilized the mesoporous structure. The average pore diameter of mesoporous microsphere was 14.3 nm. - Highlights: • Mesoporous zirconia microspheres with a diameter of 900 μm were prepared as ADS transmutation element inert matrix. • The mesoporous performance was improved after the microspheres were hydrothermally treated at 150 °C. • The specific surface area increased from 28.29 m{sup 2}/g to 61.28 m{sup 2}/g. • The hydrothermal treatment could avoid the cracking of the microspheres. • The specific surface area of mesoporous microsphere was 61.28 m{sup 2}/g and the average pore diameter was 14.3 nm.

  7. Insulin delivery through nasal route using thiolated microspheres.

    Science.gov (United States)

    Nema, Tarang; Jain, Ashish; Jain, Aviral; Shilpi, Satish; Gulbake, Arvind; Hurkat, Pooja; Jain, Sanjay K

    2013-01-01

    The aim of the present study was to investigate the potential of developed thiolated microspheres for insulin delivery through nasal route. In the present study, cysteine was immobilized on carbopol using EDAC. A total of 269.93 µmol free thiol groups per gram polymer were determined. The prepared nonthiolated and thiolated microspheres were studied for particle shape, size, drug content, swellability, mucoadhesion and in vitro insulin release. The thiolated microspheres exhibited higher mucoadhesion due to formation of covalent bonds via disulfide bridges with the mucus gel layer. Drug permeation through goat nasal mucosa of nonthiolated and thiolated microspheres were found as 52.62 ± 2.4% and 78.85 ± 3.1% in 6 h, respectively. Thiolated microspheres bearing insulin showed better reduction in blood glucose level (BGL) in comparison to nonthiolated microspheres as 31.23 ± 2.12% and 75.25 ± 0.93% blood glucose of initial BGL were observed at 6 h after nasal delivery of thiolated and nonthiolated microspheres in streptozotocin-induced diabetic rabbits.

  8. Current knowledge on biodegradable microspheres in drug delivery.

    Science.gov (United States)

    Prajapati, Vipul D; Jani, Girish K; Kapadia, Jinita R

    2015-08-01

    Biodegradable microspheres have gained popularity for delivering a wide variety of molecules via various routes. These types of products have been prepared using various natural and synthetic biodegradable polymers through suitable techniques for desired delivery of various challenging molecules. Selection of biodegradable polymers and technique play a key role in desired drug delivery. This review describes an overview of the fundamental knowledge and status of biodegradable microspheres in effective delivery of various molecules via desired routes with consideration of outlines of various compendial and non-compendial biodegradable polymers, formulation techniques and release mechanism of microspheres, patents and commercial biodegradable microspheres. There are various advantages of using biodegradable polymers including promise of development with different types of molecules. Biocompatibility, low dosage and reduced side effects are some reasons why usage biodegradable microspheres have gained in popularity. Selection of biodegradable polymers and formulation techniques to create microspheres is the biggest challenge in research. In the near future, biodegradable microspheres will become the eco-friendly product for drug delivery of various genes, hormones, proteins and peptides at specific site of body for desired periods of time.

  9. Effects of whispering gallery mode in microsphere super-resolution imaging

    Science.gov (United States)

    Zhou, Song; Deng, Yongbo; Zhou, Wenchao; Yu, Muxin; Urbach, H. P.; Wu, Yihui

    2017-09-01

    Whispering Gallery modes have been presented in microscopic glass spheres or toruses with many applications. In this paper, the possible approaches to enhance the imaging resolution by Whispering Gallery modes are discussed, including evanescent waves coupling, transformed and illustration by Whispering Gallery modes. It shows that the high-order scattering modes play the dominant role in the reconstructed virtual image when the Whispering Gallery modes exist. Furthermore, we find that the high image resolution of electric dipoles can be achieved, when the out-of-phase components exist from the illustration of Whispering Gallery modes. Those results of our simulation could contribute to the knowledge of microsphere-assisted super-resolution imaging and its potential applications.

  10. Composite Biomaterials Based on Sol-Gel Mesoporous Silicate Glasses: A Review

    Science.gov (United States)

    Baino, Francesco; Fiorilli, Sonia; Vitale-Brovarone, Chiara

    2017-01-01

    Bioactive glasses are able to bond to bone and stimulate the growth of new tissue while dissolving over time, which makes them ideal materials for regenerative medicine. The advent of mesoporous glasses, which are typically synthesized via sol-gel routes, allowed researchers to develop a broad and versatile class of novel biomaterials that combine superior bone regenerative potential (compared to traditional melt-derived glasses) with the ability of incorporating drugs and various biomolecules for targeted therapy in situ. Mesoporous glass particles can be directly embedded as a bioactive phase within a non-porous (e.g., microspheres), porous (3D scaffolds) or injectable matrix, or be processed to manufacture a surface coating on inorganic or organic (macro)porous substrates, thereby obtaining hierarchical structures with multiscale porosity. This review provides a picture of composite systems and coatings based on mesoporous glasses and highlights the challenges for the future, including the great potential of inorganic–organic hybrid sol-gel biomaterials. PMID:28952496

  11. Optimization of preparation method for ketoprofen-loaded microspheres consisting polymeric blends using simplex lattice mixture design

    Energy Technology Data Exchange (ETDEWEB)

    Das, Sanjoy Kumar, E-mail: sanjoydasju@gmail.com; Khanam, Jasmina; Nanda, Arunabha

    2016-12-01

    In the present investigation, simplex lattice mixture design was applied for formulation development and optimization of a controlled release dosage form of ketoprofen microspheres consisting polymers like ethylcellulose and Eudragit{sup ®}RL 100; when those were formed by oil-in-oil emulsion solvent evaporation method. The investigation was carried out to observe the effects of polymer amount, stirring speed and emulsifier concentration (% w/w) on percentage yield, average particle size, drug entrapment efficiency and in vitro drug release in 8 h from the microspheres. Analysis of variance (ANOVA) was used to estimate the significance of the models. Based on the desirability function approach numerical optimization was carried out. Optimized formulation (KTF-O) showed close match between actual and predicted responses with desirability factor 0.811. No adverse reaction between drug and polymers were observed on the basis of Fourier transform infrared (FTIR) spectroscopy and Differential scanning calorimetric (DSC) analysis. Scanning electron microscopy (SEM) was carried out to show discreteness of microspheres (149.2 ± 1.25 μm) and their surface conditions during pre and post dissolution operations. The drug release pattern from KTF-O was best explained by Korsmeyer-Peppas and Higuchi models. The batch of optimized microspheres were found with maximum entrapment (~ 90%), minimum loss (~ 10%) and prolonged drug release for 8 h (91.25%) which may be considered as favourable criteria of controlled release dosage form. - Graphical abstract: Optimization of preparation method for ketoprofen-loaded microspheres consisting polymeric blends using simplex lattice mixture design. - Highlights: • Simplex lattice design was used to optimize ketoprofen-loaded microspheres. • Polymeric blend (Ethylcellulose and Eudragit® RL 100) was used. • Microspheres were prepared by oil-in-oil emulsion solvent evaporation method. • Optimized formulation depicted favourable

  12. Evaluation of radiolabelled microspheres as digesta markers

    International Nuclear Information System (INIS)

    Young, B.A.; Turner, B.V.; Dixon, A.E.; Exley, D.M.; Young, S.B.; Abidin, Z.

    1991-01-01

    The suitability of microspheres as markers for measuring digesta kinetics in sheep was examined. Microspheres offer advantages of uniformity of size and density, and stability during passage through the gastrointestinal tract. They are commercially available labelled with the choice of one of eleven different radionuclides and can be easily measured in digesta and faecal material. Tests comparing several types of digesta markers gave different measures of kinetic parameters when the measurements were made concurrently in the same sheep. However, concurrent measurements derived from use of microspheres were consistent. Microspheres offer a new alternative for digestive studies. (author). 19 refs, 4 tabs

  13. Studies in the Use of Magnetic Microspheres for Immunoaffinity Extraction of Paralytic Shellfish Poisoning Toxins from Shellfish

    Directory of Open Access Journals (Sweden)

    Christopher Elliott

    2011-01-01

    Full Text Available Paralytic shellfish poisoning (PSP is a potentially fatal human health condition caused by the consumption of shellfish containing high levels of PSP toxins. Toxin extraction from shellfish and from algal cultures for use as standards and analysis by alternative analytical monitoring methods to the mouse bioassay is extensive and laborious. This study investigated whether a selected MAb antibody could be coupled to a novel form of magnetic microsphere (hollow glass magnetic microspheres, brand name Ferrospheres-N and whether these coated microspheres could be utilized in the extraction of low concentrations of the PSP toxin, STX, from potential extraction buffers and spiked mussel extracts. The feasibility of utilizing a mass of 25 mg of Ferrospheres-N, as a simple extraction procedure for STX from spiked sodium acetate buffer, spiked PBS buffer and spiked mussel extracts was determined. The effects of a range of toxin concentrations (20–300 ng/mL, incubation times and temperature on the capability of the immuno-capture of the STX from the spiked mussel extracts were investigated. Finally, the coated microspheres were tested to determine their efficiency at extracting PSP toxins from naturally contaminated mussel samples. Toxin recovery after each experiment was determined by HPLC analysis. This study on using a highly novel immunoaffinity based extraction procedure, using STX as a model, has indicated that it could be a convenient alternative to conventional extraction procedures used in toxin purification prior to sample analysis.

  14. Thermoanalytical study of the decomposition of yttrium trifluoroacetate thin films

    International Nuclear Information System (INIS)

    Eloussifi, H.; Farjas, J.; Roura, P.; Ricart, S.; Puig, T.; Obradors, X.; Dammak, M.

    2013-01-01

    We present the use of the thermal analysis techniques to study yttrium trifluoroacetate thin films decomposition. In situ analysis was done by means of thermogravimetry, differential thermal analysis, and evolved gas analysis. Solid residues at different stages and the final product have been characterized by X-ray diffraction and scanning electron microscopy. The thermal decomposition of yttrium trifluoroacetate thin films results in the formation of yttria and presents the same succession of intermediates than powder's decomposition, however, yttria and all intermediates but YF 3 appear at significantly lower temperatures. We also observe a dependence on the water partial pressure that was not observed in the decomposition of yttrium trifluoroacetate powders. Finally, a dependence on the substrate chemical composition is discerned. - Highlights: • Thermal decomposition of yttrium trifluoroacetate films. • Very different behavior of films with respect to powders. • Decomposition is enhanced in films. • Application of thermal analysis to chemical solution deposition synthesis of films

  15. A Four-Gap Glass-RPC Time-of-Flight Array with 90 ps Time Resolution

    CERN Document Server

    Akindinov, A; Formenti, F; Golovine, V; Klempt, W; Kluge, A; Martemyanov, A N; Martinengo, P; Pinhão, J; Smirnitsky, A V; Spegel, M; Szymanski, P; Zalipska, J

    2001-01-01

    In this paper, we describe the performance of a prototype developed in the context of the ALICE time-of-flight research and development system. The detector module consists of a 32-channel array of 3 x 3 cm2 glass resistive plate chamber (RPC) cells, each of which has four accurately space gaps of 0.3 mm thickness arranged as a pair of double-gap resisitive plate chambers. Operated with a nonflammable gas mixture at atmospheric pressure, the system achieved a time resolution of 90 ps at 98% efficiency with good uniformity and moderate crosstalk. This result shows the feasibility of large-area high-resolution time-of-flight systems based on RPCs at affordable cost.

  16. Robust evidence for long-term survival with {sup 90}Y radioembolization in chemorefractory liver-predominant metastatic colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jakobs, T.F. [Barmherzige Brueder Munich, Department of Diagnostic and Interventional Radiology, Munich (Germany); Paprottka, K.J.; Raessler, F.; Strobl, F.; Trumm, C.G.; Sommer, W.; Paprottka, P.M. [LMU - University of Munich, Department of Clinical Radiology, Munich (Germany); Lehner, S.; Ilhan, H.; Fendler, W.P. [LMU - University of Munich, Department of Nuclear Medicine, Munich (Germany)

    2017-01-15

    Our aim was to provide further evidence for the efficacy/safety of radioembolization using yttrium-90-resin microspheres for unresectable chemorefractory liver metastases from colorectal cancer (mCRC). We followed 104 consecutively treated patients until death. Overall survival (OS) was calculated from the day of the first radioembolization procedure. Response was defined by changes in tumour volume as defined by Response Evaluation Criteria in Solid Tumours (RECIST) v1.0 and/or a ≥30 % reduction in serum carcinoembryonic antigen (CEA) at 3 months. Survival varied between 23 months in patients who had a complete response to prior chemotherapy and 13 months in patients with a partial response or stable disease. Median OS also significantly improved (from 5.8 months to 17.1 months) if response durability to radioembolization extended beyond 6 months. Patients with a positive trend in CEA serum levels (≥30 % reduction) at 3 months post-radioembolization also had a survival advantage compared with those who did not: 15.0 vs 6.7 months. Radioembolization was well tolerated. Grade 3 increases in bilirubin were reported in 5.0 % of patients at 3 months postprocedure. After multiple chemotherapies, many patients still have a good performance status and are eligible for radioembolization. This single procedure can achieve meaningful survivals and is generally well tolerated. (orig.)

  17. Effect of Yttrium Addition on Glass-Forming Ability and Magnetic Properties of Fe–Co–B–Si–Nb Bulk Metallic Glass

    Directory of Open Access Journals (Sweden)

    Teruo Bitoh

    2015-06-01

    Full Text Available The glass-forming ability (GFA and the magnetic properties of the [(Fe0.5Co0.50.75B0.20Si0.05]96Nb4−xYx bulk metallic glasses (BMGs have been studied. The partial replacement of Nb by Y improves the thermal stability of the glass against crystallization. The saturation mass magnetization (σs exhibits a maximum around 2 at. % Y, and the value of σs of the alloy with 2 at. % Y is 6.5% larger than that of the Y-free alloy. The coercivity shows a tendency to decrease with increasing Y content. These results indicate that the partial replacement of Nb by Y in the Fe–Co–B–Si–Nb BMGs is useful to simultaneous achievement of high GFA, high σs, and good soft magnetic properties.

  18. Preparation of polystyrene microsphere with emulsion microencapsulation method

    International Nuclear Information System (INIS)

    Li Bo Zhang Lin; Zhang Zhganwen; You Dan; Wei Yun; Wang Chaoyang; Lin Bo; Shi Tao; Chu Qiaomei

    2003-01-01

    The preparation of hollow polystyrene microspheres that are used as inner shell of multi-shell plastic microspheres in the ICF experiments is focused on. The effects of surfactants, water-soluble polymer and electrolyte on the properties of resultant microspheres are studied. Based on these experiments, a fabricating procedure was established with which hollow microspheres were prepared with diameter about 150-3000 μm, wall thickness 0.8-15 μm and toughness Ra less than 4 nm. (authors)

  19. Experience with indium-111 and yttrium-90-labeled somatostatin analogs.

    Science.gov (United States)

    Virgolini, I; Traub, T; Novotny, C; Leimer, M; Füger, B; Li, S R; Patri, P; Pangerl, T; Angelberger, P; Raderer, M; Burggasser, G; Andreae, F; Kurtaran, A; Dudczak, R

    2002-01-01

    The high level expression of somatostatin receptors (SSTR) on various tumor cells has provided the molecular basis for successful use of radiolabeled octreotide / lanreotide analogs as tumor tracers in nuclear medicine. Other (nontumoral) potential indications for SSTR scintigraphy are based on an increased lymphocyte binding at sites of inflammatory or immunologic diseases such as thyroid-associated ophthalmology. The vast majority of human tumors seem to over-express the one or the other of five distinct hSSTR subtype receptors. Whereas neuroendocrine tumors frequently overexpress hSSTR2, intestinal adenocarcinomas seem to overexpress more often hSSTR3 or hSSTR4, or both of these hSSTR. In contrast to In-DTPA-DPhe(1)-octreotide (OctreoScan(R)) which binds to hSSTR2 and 5 with high affinity (Kd 0.1-5 nM), to hSSTR3 with moderate affinity (K(d) 10-100 nM) and does not bind to hSSTR1 and hSSTR4, (111)In / (90)Y-DOTA-lanreotide was found to bind to hSSTR2, 3, 4, and 5 with high affinity, and to hSSTR1 with lower affinity (K(d) 200 nM). Based on its unique hSSTR binding profile, (111)In-DOTA-lanreotide was suggested to be a potential radioligand for tumor diagnosis, and (90)Y-DOTA-lanreotide suitable for receptor-mediated radionuclide therapy. As opposed to (111)In-DTPA-DPhe(1)-octreotide and (111)In-DOTA-DPhe(1)-Tyr(3)-octreotide, discrepancies in the scintigraphic results were seen in about one third of (neuroendocrine) tumor patients concerning both the tumor uptake as well as detection of tumor lesions. On a molecular level, these discrepancies seem to be based on a "higherrdquuo; high-affinity binding of (111)In-DOTA-DPhe(1)-Tyr(3)-octreotide to hSSTR2 (K(d) 0.1-1 nM). Other somatostatin analogs with divergent affinity to the five known hSSTR subtype receptors have also found their way into the clinics, such as (99m)Tc-depreotide (NeoSpect(R); NeoTect(R)). Most of the imaging results are reported for neuroendocrine tumors (octreotide analogs) or nonsmall cell

  20. Preparation of alumina microspheres

    International Nuclear Information System (INIS)

    Santos, W.R. dos; Abrao, A.

    1980-01-01

    Inorganic exchangers are widely used for adsorption and column partition chromatography. The main difficulty of using commercial alumina (in powder) for column chromatography is related to its packing, and the operations through the column become diffcult and time-consuming; also it turns to be virtually impossible to use large dimension columns. In order to eliminate these problems, a process for the preparation of alumina micro-spheres was developed as an adaptation of a similar process used to prepare nuclear fuel microspheres (UO 2 , ThO 2 ). The flowsheet of this process is presented together with the analytical results of sphericity after calcination, granulometry, density and characterization by X-ray diffractometry. Solubility tests showed that the so-prepared microspheres are well resistant to strong acids and bases; retention tests showed their efficiency, mainly to copper. (C.L.B.) [pt

  1. Controlling silk fibroin microspheres via molecular weight distribution

    International Nuclear Information System (INIS)

    Zeng, Dong-Mei; Pan, Jue-Jing; Wang, Qun; Liu, Xin-Fang; Wang, Hui; Zhang, Ke-Qin

    2015-01-01

    Silk fibroin (SF) microspheres were produced by salting out SF solution via the addition of potassium phosphate buffer solution (K 2 HPO 4 –KH 2 PO 4 ). The morphology, size and polydispersity of SF microspheres were adjusted by changing the molecular weight (MW) distribution and concentration of SF, as well as the ionic strength and pH of the buffer solution. Changing the conditions under which the SF fiber dissolved in the Lithium Boride (LiBr) solution resulted in altering the MW distribution of SF solution. Under optimal salting-out conditions (ionic strength > 0.7 M and pH > 7) and using a smaller and narrower SF MW distribution, SF microspheres with smoother shapes and more uniform sizes were produced. Meanwhile, the size and polydispersity of the microspheres increased when the SF concentration was increased from 0.25 mg/mL to 20 mg/mL. The improved SF microspheres, obtained by altering the distribution of molecular weight, have potential in drug and gene delivery applications. - Highlights: • MW distribution was changed by applying different dissolving methods of SF fiber. • Smaller and narrower MW distribution improves the quality of SF microspheres. • Size and polydispersity of microspheres increase as SF concentration increases. • Improved SF microspheres have potential in drug and gene delivery applications

  2. Controlling silk fibroin microspheres via molecular weight distribution

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Dong-Mei; Pan, Jue-Jing; Wang, Qun; Liu, Xin-Fang; Wang, Hui [National Engineering Laboratory for Modern Silk, College for Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123 (China); Zhang, Ke-Qin, E-mail: kqzhang@suda.edu.cn [National Engineering Laboratory for Modern Silk, College for Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123 (China); Research Center of Cooperative Innovation for Functional Organic/Polymer Material Micro/Nanofabrication, Soochow University, Suzhou, Jiangsu 215123 (China)

    2015-05-01

    Silk fibroin (SF) microspheres were produced by salting out SF solution via the addition of potassium phosphate buffer solution (K{sub 2}HPO{sub 4}–KH{sub 2}PO{sub 4}). The morphology, size and polydispersity of SF microspheres were adjusted by changing the molecular weight (MW) distribution and concentration of SF, as well as the ionic strength and pH of the buffer solution. Changing the conditions under which the SF fiber dissolved in the Lithium Boride (LiBr) solution resulted in altering the MW distribution of SF solution. Under optimal salting-out conditions (ionic strength > 0.7 M and pH > 7) and using a smaller and narrower SF MW distribution, SF microspheres with smoother shapes and more uniform sizes were produced. Meanwhile, the size and polydispersity of the microspheres increased when the SF concentration was increased from 0.25 mg/mL to 20 mg/mL. The improved SF microspheres, obtained by altering the distribution of molecular weight, have potential in drug and gene delivery applications. - Highlights: • MW distribution was changed by applying different dissolving methods of SF fiber. • Smaller and narrower MW distribution improves the quality of SF microspheres. • Size and polydispersity of microspheres increase as SF concentration increases. • Improved SF microspheres have potential in drug and gene delivery applications.

  3. Antibacterial activity of ciprofloxacin-loaded zein microsphere films

    International Nuclear Information System (INIS)

    Fu Jianxi; Wang Huajie; Zhou Yanqing; Wang Jinye

    2009-01-01

    Our aim was to produce an antibiotic-emitting coating composed of zein microspheres for the prevention of bacterial infection on implanted devices. Ciprofloxacin-loaded zein microspheres were prepared using a phase separation procedure, with particle sizes between 0.5 and 2 μm. Drug encapsulation and drug loading varied with the amount of both zein and ciprofloxacin, and the highest encapsulation efficiency was 8.27% (2 mg/ml ciprofloxacin and 20 mg/ml zein; n = 3). A ciprofloxacin-loaded zein microsphere film (CF-MS film) was generated via solvent evaporation. Continuous drug release from a trypsin-degraded microsphere film was observed for up to 28 days. The liberation of ciprofloxacin from the trypsin-degraded film and the biodegradation of the microsphere film were highly correlated. Proliferation assay of the growth of human umbilical vein endothelial cells (HUVECs) by the MTT method showed that the microsphere film had no toxicity when compared with cells grown on Corning culture plates alone and plates with a zein film alone. Quantification of bacteria adhesion showed that adhesion on the microsphere film is significantly suppressed. In addition, according to the results of bacterial growth tests, ciprofloxacin-loaded microsphere films maintained antibacterial activity for more than 6 days. In contrast, a control medium containing a zein film allowed constant bacterial growth. These results indicate that CF-MS films might be useful as antibacterial films on implanted devices.

  4. Antibacterial activity of ciprofloxacin-loaded zein microsphere films

    Energy Technology Data Exchange (ETDEWEB)

    Fu Jianxi [Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 354 Fenglin Road, Shanghai 200032 (China); Henan Normal University, 46 East Construction Road, Xinxiang, Henan 453007 (China); Wang Huajie [College of Life Science and Biotechnology, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030 (China); Zhou Yanqing [Henan Normal University, 46 East Construction Road, Xinxiang, Henan 453007 (China); Wang Jinye, E-mail: jywang@mail.sioc.ac.cn [Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 354 Fenglin Road, Shanghai 200032 (China); College of Life Science and Biotechnology, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030 (China)

    2009-05-05

    Our aim was to produce an antibiotic-emitting coating composed of zein microspheres for the prevention of bacterial infection on implanted devices. Ciprofloxacin-loaded zein microspheres were prepared using a phase separation procedure, with particle sizes between 0.5 and 2 {mu}m. Drug encapsulation and drug loading varied with the amount of both zein and ciprofloxacin, and the highest encapsulation efficiency was 8.27% (2 mg/ml ciprofloxacin and 20 mg/ml zein; n = 3). A ciprofloxacin-loaded zein microsphere film (CF-MS film) was generated via solvent evaporation. Continuous drug release from a trypsin-degraded microsphere film was observed for up to 28 days. The liberation of ciprofloxacin from the trypsin-degraded film and the biodegradation of the microsphere film were highly correlated. Proliferation assay of the growth of human umbilical vein endothelial cells (HUVECs) by the MTT method showed that the microsphere film had no toxicity when compared with cells grown on Corning culture plates alone and plates with a zein film alone. Quantification of bacteria adhesion showed that adhesion on the microsphere film is significantly suppressed. In addition, according to the results of bacterial growth tests, ciprofloxacin-loaded microsphere films maintained antibacterial activity for more than 6 days. In contrast, a control medium containing a zein film allowed constant bacterial growth. These results indicate that CF-MS films might be useful as antibacterial films on implanted devices.

  5. U3O8 microspheres sintering kinetics

    International Nuclear Information System (INIS)

    Godoy, A.L.E.

    1986-01-01

    U 3 O 8 microspheres sintering kinetics was determined using a hot-stage optical microscopy apparatus, able to reach temperature up to 1350 0 C in controlled atmospheres. The sintered material had its microstructure analysed by optical and electron microscopy. The microspheres were characterized initialy utilizing X-ray diffractometry and thermogravimetry. The equation which describes the microspheres shrinkage in function of the time was obtained using finite difference analysis X-ray diffractometry indicated hexagonal structure for the microspheres main starting material, ammonium diuranate thermogravimetric analysis showed reduction of this material to U 3 O 8 at 600 0 C. Ceramography results showed 5 hours sintered microspheres grain sizes G vary with the temperature. Sintered U 3 O 8 micrographs compared with published results for UO 2 , indicate similar homogeneity microstructural characteristics and suggest the processed micorspheres to be potentially useful as nuclear fuels. (Author) [pt

  6. Preparation of UC0.07-0.10N0.90-0.93 spheres for TRISO coated fuel particles

    Science.gov (United States)

    Hunt, R. D.; Silva, C. M.; Lindemer, T. B.; Johnson, J. A.; Collins, J. L.

    2014-05-01

    The US Department of Energy is considering a new nuclear fuel that would be less susceptible to ruptures during a loss-of-coolant accident. The fuel would consist of tristructural isotropic coated particles with dense uranium nitride (UN) kernels with diameters of 650 or 800 μm. The objectives of this effort are to make uranium oxide microspheres with adequately dispersed carbon nanoparticles and to convert these microspheres into UN spheres, which could be then sintered into kernels. Recent improvements to the internal gelation process were successfully applied to the production of uranium gel spheres with different concentrations of carbon black. After the spheres were washed and dried, a simple two-step heat profile was used to produce porous microspheres with a chemical composition of UC0.07-0.10N0.90-0.93. The first step involved heating the microspheres to 2023 K in a vacuum, and in the second step, the microspheres were held at 1873 K for 6 h in flowing nitrogen.

  7. One-pot fabrication of Co{sub 3}O{sub 4} microspheres via hydrothermal method at low temperature for high capacity supercapacitor

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Chao; Zhang, Jinfeng [State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240 (China); Deng, Yida, E-mail: yida.deng@tju.edu.cn [School of Material Science and Engineering, Tianjin University, Tianjin 300072 (China); Zhong, Cheng [School of Material Science and Engineering, Tianjin University, Tianjin 300072 (China); Liu, Lei [State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240 (China); Hu, Wenbin [State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240 (China); School of Material Science and Engineering, Tianjin University, Tianjin 300072 (China)

    2015-09-15

    Highlights: • Take full advantage of the easily oxidized feature of cobalt (II) complexes ammonia. • Low temperature method was applied with absence of subsequent calcination process. • The Co{sub 3}O{sub 4} microspheres possess extraordinary electrochemical properties. - Abstract: Co{sub 3}O{sub 4} microspheres were successfully produced with one-step low temperature hydrothermal method and their electrochemical properties have been investigated. By means of utilizing easily oxidized characteristic of cobalt complexes ammonia, the Co{sub 3}O{sub 4} microspheres were synthesized for the first time with an extremely low hydrothermal temperature (100 °C). In the absent case of surfactant, these Co{sub 3}O{sub 4} microspheres with a diameter of ca. 500 nm and smooth surface were prepared with the assistance of nitrate. Influences concerning about temperature and concentration of nitrate on morphology and size distribution were thoroughly discussed. Electrochemical characterization indicated that the Co{sub 3}O{sub 4} microspheres exhibited high specific capacitance of 850, 780, 700, 630 F/g at current densities of 1, 2, 4, 8 A/g, respectively. And after 1000 cycles, the devices with Co{sub 3}O{sub 4} microspheres showed high charge/discharge reversibility with an efficiency of 90.8% at a current density of 2 A/g.

  8. Evidence of yttrium silicate inclusions in YSZ-porcelain veneers.

    Science.gov (United States)

    Stoner, Brian R; Griggs, Jason A; Neidigh, John; Piascik, Jeffrey R

    2014-04-01

    This report introduces the discovery of crystalline defects that can form in the porcelain veneering layer when in contact with yttria-stabilized zirconia (YSZ). The focus was on dental prostheses and understanding the defects that form in the YSZ/porcelain system; however the data reported herein may have broader implications toward the use and stability of YSZ-based ceramics in general. Specimens were cut from fully sintered YSZ plates and veneering porcelain was applied (X-ray (EDAX) was used for microstructural and elemental analysis. EDAX, for chemical analysis and transmission electron diffraction (TED) for structural analysis were both performed in the transmission electron microscope (TEM). Additionally, in order to spatially resolve Y-rich precipitates, micro-CT scans were conducted at varying depths within the porcelain veneer. Local EDAX (SEM) was performed in the regions of visible inclusions and showed significant increases in yttrium concentration. TEM specimens also showed apparent inclusions in the porcelain and selected area electron diffraction was performed on these regions and found the inclusions to be crystalline and identified as either yttrium-silicate (Y2 SiO5 ) or yttrium-disilicate (Y2 Si2 O7 ). Micro-CT data showed that yttrium-silicate precipitates were distributed throughout the thickness of the porcelain veneer. Future studies are needed to determine whether many of the premature failures associated with this materials system may be the result of crystalline flaws that form as a result of high temperature yttrium diffusion near the surfaces of YSZ. © 2013 Wiley Periodicals, Inc.

  9. Intra-arterial treatment with ⁹⁰Y microspheres for hepatocellular carcinoma: 4 years experience at the Ghent University Hospital.

    Science.gov (United States)

    Lambert, Bieke; Sturm, Emiel; Mertens, Jeroen; Oltenfreiter, Ruth; Smeets, Peter; Troisi, Roberto; Van Vlierberghe, Hans; Defreyne, Luc

    2011-12-01

    We report on our experience in terms of eligibility, safety, response and survival for treatment of hepatocellular carcinoma (HCC) with (90)Y microspheres. Secondly, we investigated the urinary excretion of (90)Y following treatment. We retrospectively reviewed all HCC patients referred to our department for (90)Y microsphere treatment. We recorded reasons for not proceeding to actual treatment. In case treatment was performed, we assessed the tolerance (Common Terminology Criteria for Adverse Events v3.0, CTCAE v3.0), the response [modified Response Evaluation Criteria in Solid Tumors (mRECIST) criteria] and long-term survival (Kaplan-Meier). The urinary excretion was estimated by 12-h urine collections post-injection for analysis in a gamma counter. Forty-three HCC patients were referred for radioembolization. Fourteen patients were excluded, mainly due to unfavourable (99m)Tc-macroaggregated albumin (MAA) distribution. Twenty-nine patients were treated with (90)Y microspheres (TheraSphere, mean activity 2.17 GBq). In four patients severe clinical adverse events were encountered, however only in one case clearly related to the therapy. Twenty patients were assessable by mRECIST: complete response in 15%, partial response in 35%, stable disease in 30% and progression in 20% were observed. A median survival of 12.3 months (95% confidence interval 9.4-15.2) was estimated. Concerning the substudy on urinary excretion, only 0.0025% of the administered activity was excreted in the urine within the first 12 h following TheraSphere. Following a strict workup before admitting patients to radioembolization with TheraSphere, we found good clinical tolerance in the vast majority of patients. Radiological response assessment yielded an overall response rate of 50%, when evaluated early following treatment. Urine analysis showed consistently only low activities of (90)Y excreted in the urine.

  10. Preclinical evaluation of intravenously administered 111In-and 90Y-labeled B72.3 immunoconjugate (GYK-DTPA) in beagle dogs

    International Nuclear Information System (INIS)

    Quadri, S.M.; Vriesendorp, H.M.; Yi Shao; Blum, J.E.; Leichner, P.K.; Williams, J.R.

    1993-01-01

    B72.3, a monoclonal antibody with reactivity against human adenocarcinomas was obtained from the Cytogen Corporation in the form of an immunoconjugate coupled with linker-chelator GYK-DTPA by using proprietary carbohydrate directed site specific chemistry. The immunoconjugate was radiolabeled with indium-111 or yttrium-90. A preclinical analysis was performed in 10 normal beagle dogs. The pharmacokinetics of intravenously administered indium- and yttrium-labeled immunoconjugates were compared serially in blood, bone marrow and urine samples. Compared to 90 Y less of the 111 In label ended up in urine and more was found in blood and bone marrow. Indium-labeled B72.3 GYK-DTPA had relatively higher uptake in most glandular tissues than 111 In-labeled antiferritin immunoconjugate. Bone marrow toxicity was the dose limiting side effect after intravenous infusion of 90 Y-labeled B72.3 GYK-DTPA. Toxicity was also observed in the liver but not in other organ systems. Recently other investigators obtained similar results with these immunoconjugates in human patients. A preclinical pharmacokinetic analysis of radioimmunoconjugates in beagle dogs provided useful information regarding bone marrow toxicity, liver toxicity and in vivo instability of the immunoconjugate. Data suggest that for future trials in human patients, a more stable chelated immunoconjugate for yttrium is needed to achieve less liver uptake and a better correlation with the 111 In-labeled product than the 90 Y-labeled B72.3 GYK-DTPA used in this investigation. (Author)

  11. Process for recovering yttrium and lanthanides from wet-process phosphoric acid

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, J.A.; Weterings, C.A.

    1983-06-28

    Process for recovering yttrium and lanthanides from wet-process phosphoric acid by adding a flocculant to the phosphoric acid, separating out the resultant precipitate and then recovering yttrium and lanthanides from the precipitate. Uranium is recovered from the remaining phosphoric acid.

  12. Influence of radiant heating treatments on fusion of high-temperature superconducting yttrium ceramics; Vliyanie termoradiatsionnykh obrabotok na sintez vysokotempiraturnykh sverkhprovodyaschikh ittrievykh keramik

    Energy Technology Data Exchange (ETDEWEB)

    Bitenbaev, M I; Polyakov, A I [Inst. Yadernoj Fiziki Natsionalnogo Yadernogo Tsentra Respubliki Kazakhstan, Almaty (Kazakhstan)

    1999-07-01

    Regardless of the fact that the materials made of HTSC-ceramics are promising, there is no any information about their successful practical application in publications. To our opinion, it is explained by the fact, first of all, that the conservative technologies of the powder metallurgy do not allow producing HTSC systems with excellent operating performance (structure homogeneity, long-term stability of Sc properties and etc.). This report presents outcomes of experiments on fusion of yttrium ceramics containing raw components irradiated by g-rays {sup 60}Co under the temperature exceeding 500 degrees C. HTSC properties of ceramics were studied according to their differential spectra of radio-frequency (RF) field absorption. The RF absorption spectrum of yttrium ceramics samples produced according to conservative technology is sufficiently permitted triplet with the Sc transition temperatures range of 80 K, 90 K, 95 K. Irradiation under the increased temperatures and mechanical limitation allow producing samples of yttrium HTSC-ceramics with sufficient homogeneous structure and superconducting properties that are stable to air conditions for not less than one year.

  13. Relative leach behavior of waste glasses and naturally occurring glasses

    International Nuclear Information System (INIS)

    Adams, P.B.

    1979-01-01

    Simulated nuclear waste glasses of the sodium-borosilicate type with a low waste loading and of the zinc-borosilicate type with a high waste loading have been compared with obsidians. The resuls indicate that the waste glasses would corrode in normal natural environments at a rate of about 0.1 μm per year at 30 0 C and about 5 μm per year at 90 0 C, compared with obsidians which seem to corrode at, or less than, about 0.01 μm per year at 30 0 C and less than 1 μm per year at 90 0 C. Activation energies for reactions of the two waste glasses with pure water are about 20 kcal/g-mol. 3 figures, 7 tables

  14. Aqueous corrosion of silicate glasses. Analogy between volcanic glasses and the French nuclear waste glass R7T7

    International Nuclear Information System (INIS)

    Goldschmidt, F.

    1991-01-01

    The behaviour of borosilicate glasses upon aqueous corrosion is controlled for long periods of time (>10,000 years) by processes which are not directly accessible by means of laboratory experiments. The analogical approach consists here to compare leaching performances between the french nuclear waste glass R7T7 and natural volcanic glasses, basaltic and rhyolitic ones. The three glasses were leached in the same conditions; open system, 90 deg C, initial pH of 9.7. Basaltic and R7T7 glasses having the same kinetic of dissolution, the basaltic glass was chosen as the best analogue. (author). refs., figs., tabs

  15. Photocatalysis of Yttrium Doped BaTiO3 Nanofibres Synthesized by Electrospinning

    Directory of Open Access Journals (Sweden)

    Zhenjiang Shen

    2015-01-01

    Full Text Available Yttrium doped barium titanate (BT nanofibres (NFs with significant photocatalytic effect were successfully synthesized by electrospinning. Considering the necessary factors for semiconductor photocatalysts, a well-designed procedure was carried out to produce yttrium doped BT (BYT NFs. In contrast to BYT ceramics powders and BT NFs, BYT NFs with pure perovskite phase showed much enhanced performance of photocatalysis. The surface modification in electrospinning and subsequent annealing, the surface spreading of transition metal yttrium, and the narrowed band gap energy in yttrium doping were all contributed to the final novel photocatalytic effect. This work provides a direct and efficient route to obtain doped NFs, which has a wide range of potential applications in areas based on complex compounds with specific surface and special doping effect.

  16. Radiochemistry, pre-clinical studies and first clinical investigation of 90Y-labeled hydroxyapatite (HA) particles prepared utilizing 90Y produced by (n,γ) route

    International Nuclear Information System (INIS)

    Vimalnath, K.V.; Chakraborty, Sudipta; Rajeswari, A.; Sarma, H.D.; Nuwad, Jitendra; Pandey, Usha; Kamaleshwaran, K.; Shinto, Ajit; Dash, Ashutosh

    2015-01-01

    Introduction: The scope of using no carrier added (NCA) 90 Y [T 1/2 = 64.1 h, E β(max) = 2.28 MeV] obtained from 90 Sr/ 90 Y generator in radiation synovectomy (RSV) is widely accepted. In the present study, the prospect of using 90 Y produced by (n,γ) route in a medium flux research reactor for use in RSV was explored. Methods: Yttrium-90 was produced by thermal neutron irradiation of Y 2 O 3 target at a neutron flux of ~ 1 × 10 14 n/cm 2 .s for 14 d. The influence of various experimental parameters were systematically investigated and optimized to arrive at the most favorable conditions for the formulation of 90 Y labeled hydroxyapatite (HA) using HA particles of 1–10 μm size range. An optimized kit formulation strategy was developed for convenient one-step compounding of 90 Y-HA, which is easily adaptable at hospital radiopharmacy. The pre-clinical biological evaluation of 90 Y-HA particles was studied by carrying out biodistribution and bioluminiscence imaging studies in Wistar rats. The first clinical investigation using the radiolabeled preparation was performed on a patient suffering from chronic arthritis in knee joint by administering 185 MBq 90 Y-HA formulated at the hospital radiopharmacy deploying the proposed strategy. Results: Yttrium-90 was produced with a specific activity of 851 ± 111 MBq/mg and radionuclidic purity of 99.95 ± 0.02%. 90 Y-labeled HA particles (185 ± 10 MBq doses) were formulated in high radiochemical purity (> 99%) and excellent in vitro stability. The preparation showed promising results in pre-clinical studies carried out in Wistar rats. The preliminary results of the first clinical investigation of 90 Y-HA preparation in a patient with rheumatoid arthritis in knee joints demonstrated the effectiveness of the formulation prepared using 90 Y produced via (n,γ) route in the management of the disease. Conclusion: The studies revealed that effective utilization of 90 Y produced via (n,γ) route in a medium flux research

  17. Encapsulated PDMS microspheres with reactive handles

    DEFF Research Database (Denmark)

    Gonzalez, Lidia; Ma, Baoguang; Li, Li

    2014-01-01

    , cured PDMS microspheres are coated with poly(methyl methacrylate) using a chemical process (solvent evaporation technique). Three solvents are used in three different experiments: dichloromethane, tetrahydrofuran, and acetone. The composition and morphology of the cured PDMS microspheres and PMMA coated...

  18. Microencapsulation and microspheres for food applications

    NARCIS (Netherlands)

    Sagis, L.M.C.

    2015-01-01

    This book provides an update on the latest developments, challenges, and opportunities in the highly expanding field of microencapsulation and microspheres for food applications, examining the various types of microspheres and microcapsules essential to those who need to develop stable and

  19. An ICP AES method for determination of dysprosium and terbium in high purity yttrium oxide

    International Nuclear Information System (INIS)

    Rupawate, V.H.; Hareendran, K.N.; Roy, S.B.

    2011-01-01

    High purity yttrium finds interesting application in astronavigation, luminescence, nuclear energy and metallurgical industries. Most of these applications require yttrium oxide of highest purity. Consequently there is a need for production of high purity yttrium oxide. Separation and purification of yttrium from other rare earths is a challenging task due to their close chemical properties. Liquid-liquid extraction and ion exchange have been widely used in the production of yttrium oxide of highest purity. Determination of impurities, especially other rare earths, in ppm level is required for process development and chemical characterization of the high purity Y 2 O 3 . Many methods have been described in literature. However since the advent of ICP AES much work in this area has been carried out by this technique. This paper describes the work done for determination of dysprosium (Dy) and terbium (Tb) in yttrium oxide using a high resolution sequential ICP AES. Emission spectra of rare earth elements are very complex and due to this complexity it is important to select spectral interference free analyte lines for determination of rare earths in rare earth matrix. For the determination of Dy and Tb in Y 2 O 3 , sensitive lines of Dy and Tb are selected from the instrument wavelength table and spectral interference free emission lines for the determination is selected by scanning around the selected wavelengths using 5 g/L Y solution and 5 mg/L standard solutions of Dy and Tb prepared in 4% nitric acid. It is found 353.170 nm line of Dy and 350.917 nm line Tb is suitable for quantitative determination. The signal to background ratio increases with increase in matrix concentration, i.e. from 1 to 5 mg/L. The optimum forward power is determined and it is found to be 1100W for Dy and 1000W for Tb. The instrument is calibrated using matrix matched standards containing 5g/L of Y matrix. Samples are dissolved in nitric acid and Y concentration is maintained at 5g/L. Two

  20. Preparation and properties of yttrium iron garnet microcrystal in $P_{2}O_{5}-MgO$ glass

    CERN Document Server

    Chen, G J; Chang, Y S; Lee, H M; Lin, Y J; 10.1016/j.jallcom.2004.07.041

    2005-01-01

    The fabrication of phosphorus-based glasses containing Y/sub 3/Fe/sub 5/O/sub 12/ crystals by the incorporation method was studied. From transmission electron microscopy observation, there is only one rod- like crystalline phase identified as Y/sub 3/Fe/sub 5/O/sub 12/ existing in the glass matrix. When the content of YIG is 30wt.%, the as-cast sample shows a Faraday rotation of 85 degrees /cm and a magnetization of 0.4emu/g in a field of 14kOe. After heat treatment, the magnetic and optical properties of the glass ceramic changed owing to the thermal diffusion of iron ions into the glass matrix.

  1. A retrospective review of Y90 synovectomy in Auckland

    International Nuclear Information System (INIS)

    Stamp, L.

    2000-01-01

    Full text: A retrospective review of Yttrium 90 synovectomies carried out from June 1997 to February 1999 in Auckland Hospital to determine outcome from the procedure. Methods: Patients were sent a questionnaire for each treated knee The principal outcome measures assessed in the month prior and the 6 months after the Y90 were pain, swelling, walking distance and overall disability score. Referring doctors were sent a questionnaire to provide information on duration of synovitis and treatment. Outcomes measured were presence of effusion 6 months after the Y90, requirement for intra-articular steroid in the 12 months prior to and after the yttrium and change of therapy due lo ongoing symptoms in the treated knee. Results: 29 patients and 40 knees had Y90 during the study period 86% patients with 87.5% knees responded. Referring doctors for 86% patients accounting for 87.5% knees responded. The procedure was well tolerated with the majority of patients reporting nil-mild discomfort during and in the 24 hours after Y90. 86% knees treated reported improvement with a reduction in pain and swelling Patient global assessment reduced from 3.8 to 2.0 while physician global assessment reduced from 3.9 to 3.0. There was an improvement in walking distance 6 months after Y90 with the number of knees able to walk >1km increasing from 2 to 17 14 of 25 patients required a change in treatment because of ongoing problems in the treated knee and one patient has undergone knee joint replacement One further patient is waiting knee joint replacement The need for intra-articular steroid was reduced with 83%, knees having an average of 2.4 steroid injections in the 12 months prior to Y90 compared to 38% knees having an average of 0.7 steroid injections in the 12 months after Y90. Of the 30 knees reporting Improvement 24 knees are at least 12 months post Y90. Of these 50% were Improved at 12 months. As a result of this audit we continue to offer this procedure in the Auckland area, and

  2. A reproducible accelerated in vitro release testing method for PLGA microspheres.

    Science.gov (United States)

    Shen, Jie; Lee, Kyulim; Choi, Stephanie; Qu, Wen; Wang, Yan; Burgess, Diane J

    2016-02-10

    The objective of the present study was to develop a discriminatory and reproducible accelerated in vitro release method for long-acting PLGA microspheres with inner structure/porosity differences. Risperidone was chosen as a model drug. Qualitatively and quantitatively equivalent PLGA microspheres with different inner structure/porosity were obtained using different manufacturing processes. Physicochemical properties as well as degradation profiles of the prepared microspheres were investigated. Furthermore, in vitro release testing of the prepared risperidone microspheres was performed using the most common in vitro release methods (i.e., sample-and-separate and flow through) for this type of product. The obtained compositionally equivalent risperidone microspheres had similar drug loading but different inner structure/porosity. When microsphere particle size appeared similar, porous risperidone microspheres showed faster microsphere degradation and drug release compared with less porous microspheres. Both in vitro release methods investigated were able to differentiate risperidone microsphere formulations with differences in porosity under real-time (37 °C) and accelerated (45 °C) testing conditions. Notably, only the accelerated USP apparatus 4 method showed good reproducibility for highly porous risperidone microspheres. These results indicated that the accelerated USP apparatus 4 method is an appropriate fast quality control tool for long-acting PLGA microspheres (even with porous structures). Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Encapsulation of naproxen in lipid-based matrix microspheres: characterization and release kinetics.

    Science.gov (United States)

    Bhoyar, P K; Morani, D O; Biyani, D M; Umekar, M J; Mahure, J G; Amgaonkar, Y M

    2011-04-01

    The objective of this study was to microencapsulate the anti-inflammatory drug (naproxen) to provide controlled release and minimizing or eliminating local side effect by avoiding the drug release in the upper gastrointestinal track. Naproxen was microencapsulated with lipid-like carnauba wax, hydrogenated castor oil using modified melt dispersion (modified congealable disperse phase encapsulation) technique. Effect of various formulation and process variables such as drug-lipid ratio, concentration of modifier, concentration of dispersant, stirring speed, stirring time, temperature of external phase, on evaluatory parameters such as size, entrapment efficiency, and in vitro release of naproxen were studied. The microspheres were characterized for particle size, scanning electron microscopy (SEM), FT-IR spectroscopy, drug entrapment efficiency, in vitro release studies, for in vitro release kinetics. The shape of microspheres was found to be spherical by SEM. The drug entrapment efficiency of various batches of microspheres was found to be ranging from 60 to 90 %w/w. In vitro drug release studies were carried out up to 24 h in pH 7.4 phosphate buffer showing 50-65% drug release. In vitro drug release from all the batches showed better fitting with the Korsmeyer-Peppas model, indicating the possible mechanism of drug release to be by diffusion and erosion of the lipid matrix.

  4. Determination of Ideal Broth Formulations Needed to Prepare Hydrous Cerium Oxide Microspheres via the Internal Gelation Process

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Jack Lee [ORNL; Chi, Anthony [ORNL

    2009-02-01

    A simple test tube methodology was used to determine optimum process parameters for preparing hydrous cerium oxide microspheres via the internal gelation process.1 Broth formulations of cerium ammonium nitrate [(NH4)2Ce(NO3)6], hexamethylenetetramine, and urea were found that can be used to prepare hydrous cerium oxide gel spheres in the temperature range of 60 to 90 C. A few gel-forming runs were made in which microspheres were prepared with some of these formulations to be able to equate the test-tube gelation times to actual gelation times. These preparations confirmed that the test-tube methodology is reliable for determining the ideal broth formulations.

  5. Magnetic poly(glycidyl methacrylate) microspheres for protein capture.

    Science.gov (United States)

    Koubková, Jana; Müller, Petr; Hlídková, Helena; Plichta, Zdeněk; Proks, Vladimír; Vojtěšek, Bořivoj; Horák, Daniel

    2014-09-25

    The efficient isolation and concentration of protein antigens from complex biological samples is a critical step in several analytical methods, such as mass spectrometry, flow cytometry and immunochemistry. These techniques take advantage of magnetic microspheres as immunosorbents. The focus of this study was on the development of new superparamagnetic polymer microspheres for the specific isolation of the tumor suppressor protein p53. Monodisperse macroporous poly(glycidyl methacrylate) (PGMA) microspheres measuring approximately 5 μm and containing carboxyl groups were prepared by multistep swelling polymerization of glycidyl methacrylate (GMA), 2-[(methoxycarbonyl)methoxy]ethyl methacrylate (MCMEMA) and ethylene dimethylacrylate (EDMA) as a crosslinker in the presence of cyclohexyl acetate as a porogen. To render the microspheres magnetic, iron oxide was precipitated within their pores; the Fe content in the particles received ∼18 wt%. Nonspecific interactions between the magnetic particles and biological media were minimized by coating the microspheres with poly(ethylene glycol) (PEG) terminated by carboxyl groups. The carboxyl groups of the magnetic PGMA microspheres were conjugated with primary amino groups of mouse monoclonal DO-1 antibody using conventional carbodiimide chemistry. The efficiency of protein p53 capture and the degree of nonspecific adsorption on neat and PEG-coated magnetic microspheres were determined by western blot analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Dental pulp stem cells immobilized in alginate microspheres for applications in bone tissue engineering.

    Science.gov (United States)

    Kanafi, M M; Ramesh, A; Gupta, P K; Bhonde, R R

    2014-07-01

    To immobilize dental pulp stem cells (DPSC) in alginate microspheres and to determine cell viability, proliferation, stem cell characteristics and osteogenic potential of the immobilized DPSCs. Human DPSCs isolated from the dental pulp were immobilized in 1% w/v alginate microspheres. Viability and proliferation of immobilized DPSCs were determined by trypan blue and MTT assay, respectively. Stem cell characteristics of DPSCs post immobilization were verified by labelling the cells with CD73 and CD90. Osteogenic potential of immobilized DPSCs was assessed by the presence of osteocalcin. Alizarin red staining and O-cresolphthalein complexone method confirmed and quantified calcium deposition. A final reverse transcriptase PCR evaluated the expression of osteogenic markers - ALP, Runx-2 and OCN. More than 80% of immobilized DPSCs were viable throughout the 3-week study. Proliferation appeared controlled and consistent unlike DPSCs in the control group. Presence of CD73 and CD90 markers confirmed the stem cell nature of immobilized DPSCs. The presence of osteocalcin, an osteoblastic marker, was confirmed in the microspheres on day 21. Mineralization assays showed high calcium deposition indicating elevated osteogenic potential of immobilized DPSCs. Osteogenic genes- ALP, Runx-2 and OCN were also upregulated in immobilized DPSCs. Surprisingly, immobilized DPSCs in the control group cultured in conventional stem cell media showed upregulation of osteogenic genes and expressed osteocalcin. Dental pulp stem cells immobilized in alginate hydrogels exhibit enhanced osteogenic potential while maintaining high cell viability both of which are fundamental for bone tissue regeneration. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  7. Yttrium addition for high temperatures stainless steel

    International Nuclear Information System (INIS)

    Furtado, Nelson Cesar Chaves Pinto

    1997-07-01

    The current work studied the effect of Yttrium on the microstructure of 2% Nb, modified - HP steel, with respect to its mechanical properties. Alloys were prepared with nominal Yttrium additions of 0,1% and 0,25%. Microstructural analyses and mechanical tests were undertaken in the as-cast condition and after ageing for 100 h at 700 deg C, 900 deg C and 1100 deg C. Structural characterization was performed by optical microscopy, scanning and transmission electron microscopy (SEM/TEM/EDS), X-ray diffractometry and X-ray photoelectron spectroscopy (XPS). Tensile testing was performed at room temperature and 871 deg C and creep testing at 925 deg C at a loading of 55 MPa. The material produced exhibited superior mechanical properties and surface oxidation resistance than traditional alloys of this class, even through gravity cast in a magnetic furnace. Agglomerates of Yttrium-rich phases were identifies in both as-cast and aged specimens, always associated with chromium carbides of characteristic morphologies. These morphologies, combined with the microstructural constituents, may have established the factors which resulted in the improved metallurgical stability of these alloys under the experimental testing conditions and temperatures which simulated real industrial service conditions and temperatures. (author)

  8. Experiments with polymer coated microspheres irradiated by the Shiva laser system

    International Nuclear Information System (INIS)

    Auerbach, J.M.; Manes, K.R.; Matthews, D.L.

    1979-01-01

    Polymer coated spherical targets have been irradiated by the Shiva laser system in an effort to compress the contained 10 mg/cc DT fuel to super liquid densities. Glass microspheres of 140 μm ID and 5 μm wall thickness with polymer coatings 15 μm to 100 μm thick have been irradiated with laser pulses of 4 kilojoules in 200 psec FWHM. Target performance was diagnosed with neutron yield measurements, radiochemistry, Argon line imaging, and x-ray imaging techniques. Ball in plate targets achieved greater implosion symmetry than free-standing ball targets. With yields of 10 7 to 10 8 neutrons, targets reached DT fuel compressions of several times liquid density

  9. Albumin microspheres labeled with Ga-67 by chelation: concise communication

    International Nuclear Information System (INIS)

    Hnatowich, D.J.; Schlegel, P.

    1981-01-01

    Albumin microspheres have been synthesized with EDTA and DTPA chelating groups covalently bound to their surface. The microspheres may be labeled with Ga-67 at high yield (97 +- 2%) by transcomplexation from a 0.1 M Ga-67 acetate solution. With EDTA microspheres the resulting label dissociates only slightly after 24 hr in 50% plasma at 37 0 C, whereas with DTPA microspheres the label shows no detectable dissociation over this period. By contrast, microspheres without chelating groups lose their label virtually completely under these conditions. Following intravenous administration of sized Ga-67 DTPA microspheres in mice, about (84 +- 16)% of the activity localizes in the lungs at 5 min, with (60 +- 7)% remaining after 2 h. Since labeling is by chelation, the microspheres may also be tagged with other metallic radionuclides

  10. Mechanisms and kinetics laws of inactive R7T7 reference glass dissolution in water at 90 deg C: initial dissolution rate measurements

    International Nuclear Information System (INIS)

    Advocat, T.; Ghaleb, D.; Vernaz, E.

    1993-02-01

    The initial dissolution rate of inactive R7T7 reference glass was measured at 90 deg C in dilute aqueous solutions first at unspecified pH, then with imposed pH values. In distilled water, R7T7 glass corrosion initially involved preferential extraction of boron and network modifier elements (Li, Na, Ca) as long as the solution pH remained acid. When the solution pH became alkaline, glass dissolution was stoichiometric. These two mechanisms were confirmed by dissolution tests in aqueous solutions at imposed pH values under acid and alkaline conditions. The initial dissolution rate r 0 in mole.cm -3 .s -1 also increased significantly in alkaline media when the pH of the aqueous phase increased: in slightly acid media, selective glass dissolution formed a residual, de-alkalinized, hydrated glass that was characterized by transmission electron microscopy and secondary ion mass spectrometry. Under steady-state dissolution conditions, the initial glass corrosion rate (in mole.cm -3 .s -1 ) was: in acid and alkaline media, amorphous and crystallized alteration products formed after complete dissolution of the silicated glass network. The first products formed consisted mainly of Zr, Rare Earths, Fe and Al. (author). 67 refs., 29 figs., 26 tabs., 21 plates

  11. Optically Levitated Microspheres as a Probe for New Interactions

    Science.gov (United States)

    Rider, Alexander; Moore, David; Blakemore, Charles; Lu, Marie; Gratta, Giorgio

    2016-03-01

    We are developing novel techniques to probe new interactions at micron distances using optically levitated dielectric microspheres. Levitated microspheres are an ideal probe for short-range interactions because they are suspended using the radiation pressure at the focus of a laser beam, which means that the microspheres can be precisely manipulated and isolated from the surrounding environment at high vacuum. We have performed a search for unknown charged particles bound within the bulk of the microspheres. Currently, we are searching for the presence of a Chameleon field postulated to explain the presence of dark energy in the universe. In the future we plan to use optically levitated microspheres to search for micron length-scale gravity like interactions that could couple between a microsphere and another mass. We will present resent results from these experiments and plans for future searches for new interactions.

  12. Silicon Microspheres Photonics

    International Nuclear Information System (INIS)

    Serpenguzel, A.

    2008-01-01

    Electrophotonic integrated circuits (EPICs), or alternatively, optoelectronic integrated circuit (OEICs) are the natural evolution of the microelectronic integrated circuit (IC) with the addition of photonic capabilities. Traditionally, the IC industry has been based on group IV silicon, whereas the photonics industry on group III-V semiconductors. However, silicon based photonic microdevices have been making strands in siliconizing photonics. Silicon microspheres with their high quality factor whispering gallery modes (WGMs), are ideal candidates for wavelength division multiplexing (WDM) applications in the standard near-infrared communication bands. In this work, we will discuss the possibility of using silicon microspheres for photonics applications in the near-infrared

  13. Preparation of UN microspheres by internal gelation process

    Energy Technology Data Exchange (ETDEWEB)

    Shirasu, Yoshiro; Yamagishi, Shigeru [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-07-01

    UN microspheres were prepared from (UO{sub 3}+C) microspheres internally gelled in a hot silicone oil column. The gel microspheres were calcined at 480degC in nitrogen, after washing and drying. The calcined ones were carbothermically nitrided at 1400-1800degC in a nitrogen-based atmosphere in two ways: one in N{sub 2} followed by N{sub 2}-8%H{sub 2}, and the other in N{sub 2}-8%H{sub 2} only. In both cases, highly pure UN microspheres around 500 ppm of both oxygen and carbon impurities were obtained, although their densities were still low. (author)

  14. Synthesis of yttrium silicate luminescent materials by sol-gel method

    International Nuclear Information System (INIS)

    Arkhipov, D.V.; Vasina, O.Yu.; Popovich, N.V.; Galaktionov, S.S.; Soshchin, N.P.

    1996-01-01

    Several yttrium-silicate composition with Y 2 O 3 content within 44-56% have been synthesized. it is ascertained that employment of sol-gel technique permits preparation of luminescent materials on yttrium silicate basis, which compare favourably with bath-produced specimens. The influence of phase composition of sol-gel phosphors on basic performance indices: intensity and luminescence spectrum, has been analyzed

  15. On the relations between ISE and structure in some RE(Mg)SiAlO(N) glasses

    DEFF Research Database (Denmark)

    Keding, Ralf; Dauce, Rachel; Sangleboeuf, J. C.

    2008-01-01

    silicate units and SiO3N and SiO2N2 units are created when nitrogen is introduced into the glass network. The average number of rigid bonds per network former was calculated from the glasses’ composition. A discrepancy between and the Raman spectra of the glasses suggests that parts of the magnesium...... Six oxide and oxynitride glasses were synthesized in the Y–Mg–Si–Al–O–N, Nd–Mg–Si–Al–O–N and La–Mg–Si–Al–O–N systems. As already known, nitrogen introduction increases the T g, packing factor and mechanical properties of the glasses. Cationic substitution also has an influence on the glasses......’ behavior, particularly in terms of sensitivity to indentation load/size effect (ISE). The structure of the yttrium-containing glasses was investigated by mean of 27Al and 29Si MAS-NMR. Al is found to occur for 2/3 as a network former and for 1/3 as a modifier. The oxide glass mainly contains Q2 and Q3...

  16. 188Re-microspheres of albumin - the potential preparation for radiotherapy

    International Nuclear Information System (INIS)

    Dyomin, D.N.; Petriev, V.M.

    2000-01-01

    In this paper author describe preparation the albumin microspheres labelled with rhenium-188. We undertake an attempt to develop kits to the generator of rhenium-188 on the basis of albumin microspheres for radiotherapy of both oncological and non-oncological diseases. Microspheres, rhenium-188 with sizes 1 0-20 micron for treatment of rheumatoid arthritis (damage of large and intermediate joints), intraperitoneal administration and intrapleural administration at metastases covering a cavity. Microspheres, Re-188 with sizes 40-60 micron for treatment of disseminated kidney cancer (intraarterial, selectively), intratumoral administration to damaged nodules less than 2-3 cm. Microspheres, Re-188 with sizes 80-100 micron for large neoplasms and metastases of liver (intraarterial, selectively), intratumoral administration to damaged nodules with sizes over 3 cm. Preparation of albumin microspheres is carried out by thermal denaturation of protein in vegetable oil. Microspheres are obtained with the necessary range of sizes by ultrasonic fractionation. At our laboratory the method of preparation of albumin microspheres with any sizes of particles (from 5 -10 up to 800 -1000 microns) has been developed. (authors)

  17. Alteration of nuclear glass in contact with iron and claystone at 90 °C under anoxic conditions: Characterization of the alteration products after two years of interaction

    International Nuclear Information System (INIS)

    Schlegel, Michel L.; Martin, Christelle; Brucker, Florence; Bataillon, Christian; Blanc, Cécile; Chorro, Matthieu; Jollivet, Patrick

    2016-01-01

    The present study investigates the alteration of a fractured glass block in contact with iron and Callovo-Oxfordian claystone at 90 °C under anoxic and water-saturated conditions. The alteration rates and the nature of glass alteration products at the different compact interfaces (glass-clay, glass-iron) and in cracks were assessed by solution chemistry and microscopic-scale techniques (scanning electron microscopy coupled with energy-dispersive X-ray microscopy, microRaman spectroscopy, and X-ray absorption fine structure spectroscopy). A significant but modest (two-fold) increase in glass alteration in contact with steel was observed, leading to an average alteration rate over the experiment of about 0.007–0.014 g/m"2/d. This rate is significantly lower than forward rate r_0 in clay-equilibrated groundwater (1.7 g/m"2/d), indicating that a decrease of the alteration rate was not hindered by the steel presence. The corrosion–alteration interface was made up of successive layers of corrosion products in contact with iron, a layer of Fe silicates, and an altered glass layer enriched in Fe. Characterization of the glass block in direct contact with claystone revealed that the thickness of altered glass was much more important than at the glass-iron interface. The altered glass layer in contact with clay was slightly enriched in Fe and Mg, and depleted in alkali cations. Altered glass layers in cracks were usually limited to fringes thinner than 2 μm, with a thickness decreasing from the crack mouth, indicating that alteration is controlled by transport in the cracks. The fractures were partially filled with calcite and lanthanide hydroxocarbonate precipitates. These results contribute to the understanding of nuclear vitrified waste-iron-corrosion products interactions in a deep geological repository. - Highlights: • Anoxic alteration of glass in contact with iron and clay at 90 °C for two-years. • Alteration rates of 0.015 and 0.5 g/m"2/d at glass

  18. Dosimetry and prescription in liver radioembolization with 90Y microspheres: 3D calculation of tumor-to-liver ratio from global 99mTc-MAA SPECT information

    Science.gov (United States)

    Mañeru, Fernando; Abós, Dolores; Bragado, Laura; Fuentemilla, Naiara; Caudepón, Fernando; Pellejero, Santiago; Miquelez, Santiago; Rubio, Anastasio; Goñi, Elena; Hernández-Vitoria, Araceli

    2017-12-01

    Dosimetry in liver radioembolization with 90Y microspheres is a fundamental tool, both for the optimization of each treatment and for improving knowledge of the treatment effects in the tissues. Different options are available for estimating the administered activity and the tumor/organ dose, among them the so-called partition method. The key factor in the partition method is the tumor/normal tissue activity uptake ratio (T/N), which is obtained by a single-photon emission computed tomography (SPECT) scan during a pre-treatment simulation. The less clear the distinction between healthy and tumor parenchyma within the liver, the more difficult it becomes to estimate the T/N ratio; therefore the use of the method is limited. This study presents a methodology to calculate the T/N ratio using global information from the SPECT. The T/N ratio is estimated by establishing uptake thresholds consistent with previously performed volumetry. This dose calculation method was validated against 3D voxel dosimetry, and was also compared with the standard partition method based on freehand regions of interest (ROI) outlining on SPECT slices. Both comparisons were done on a sample of 20 actual cases of hepatocellular carcinoma treated with resin microspheres. The proposed method and the voxel dosimetry method yield similar results, while the ROI-based method tends to over-estimate the dose to normal tissues. In addition, the variability associated with the ROI-based method is more extreme than the other methods. The proposed method is simpler than either the ROI or voxel dosimetry approaches and avoids the subjectivity associated with the manual selection of regions.

  19. Microsphere-based super-resolution scanning optical microscope.

    Science.gov (United States)

    Huszka, Gergely; Yang, Hui; Gijs, Martin A M

    2017-06-26

    High-refractive index dielectric microspheres positioned within the field of view of a microscope objective in a dielectric medium can focus the light into a so-called photonic nanojet. A sample placed in such nanojet can be imaged by the objective with super-resolution, i.e. with a resolution beyond the classical diffraction limit. However, when imaging nanostructures on a substrate, the propagation distance of a light wave in the dielectric medium in between the substrate and the microsphere must be small enough to reveal the sample's nanometric features. Therefore, only the central part of an image obtained through a microsphere shows super-resolution details, which are typically ∼100 nm using white light (peak at λ = 600 nm). We have performed finite element simulations of the role of this critical distance in the super-resolution effect. Super-resolution imaging of a sample placed beneath the microsphere is only possible within a very restricted central area of ∼10 μm 2 , where the separation distance between the substrate and the microsphere surface is very small (∼1 μm). To generate super-resolution images over larger areas of the sample, we have fixed a microsphere on a frame attached to the microscope objective, which is automatically scanned over the sample in a step-by-step fashion. This generates a set of image tiles, which are subsequently stitched into a single super-resolution image (with resolution of λ/4-λ/5) of a sample area of up to ∼10 4 μm 2 . Scanning a standard optical microscope objective with microsphere therefore enables super-resolution microscopy over the complete field-of-view of the objective.

  20. Optimization of sustained release aceclofenac microspheres using response surface methodology

    Energy Technology Data Exchange (ETDEWEB)

    Deshmukh, Rameshwar K.; Naik, Jitendra B., E-mail: jitunaik@gmail.com

    2015-03-01

    Polymeric microspheres containing aceclofenac were prepared by single emulsion (oil-in-water) solvent evaporation method using response surface methodology (RSM). Microspheres were prepared by changing formulation variables such as the amount of Eudragit® RS100 and the amount of polyvinyl alcohol (PVA) by statistical experimental design in order to enhance the encapsulation efficiency (E.E.) of the microspheres. The resultant microspheres were evaluated for their size, morphology, E.E., and in vitro drug release. The amount of Eudragit® RS100 and the amount of PVA were found to be significant factors respectively for determining the E.E. of the microspheres. A linear mathematical model equation fitted to the data was used to predict the E.E. in the optimal region. Optimized formulation of microspheres was prepared using optimal process variables setting in order to evaluate the optimization capability of the models generated according to IV-optimal design. The microspheres showed high E.E. (74.14 ± 0.015% to 85.34 ± 0.011%) and suitably sustained drug release (minimum; 40% to 60%; maximum) over a period of 12 h. The optimized microspheres formulation showed E.E. of 84.87 ± 0.005 with small error value (1.39). The low magnitudes of error and the significant value of R{sup 2} in the present investigation prove the high prognostic ability of the design. The absence of interactions between drug and polymers was confirmed by Fourier transform infrared (FTIR) spectroscopy. Differential scanning calorimetry (DSC) and X-ray powder diffractometry (XRPD) revealed the dispersion of drug within microspheres formulation. The microspheres were found to be discrete, spherical with smooth surface. The results demonstrate that these microspheres could be promising delivery system to sustain the drug release and improve the E.E. thus prolong drug action and achieve the highest healing effect with minimal gastrointestinal side effects. - Highlights: • Aceclofenac microspheres

  1. Preparation of polymer microspheres by radiation-induced polymerization

    International Nuclear Information System (INIS)

    Naka, Y.; Yamamoto, Y.; Yoshida, Y.; Tagawa, S.

    1995-01-01

    Cross-liking monomer, diethylene glycol dimethacrylate gives microspheres from organic solution by radiation-induced polymerization. /One of the remarkable result is that the number of the microspheres is not changing during the polymerization. Ethyl methacrylate, maleic anhydride, styrene and acrylamide are used as comonomers. These comonomers give the microspheres in the range of 0 to 0.4 as mol fractions. (author)

  2. Study of behaviour of lanthanum- and yttrium electrodes in chloride melts

    International Nuclear Information System (INIS)

    Shkol'nikov, S.I.; Tolypin, E.S.; Yur'ev, B.P.

    1984-01-01

    A study was made on the lanthanum- and yttrium behaviour in a mixture of molten potassium- and sodium chlorides at various temperatures. It is shown that the lanthanum- and yttrium behaviour in KCl-NaCl melt is similar to the behaviour of other metals. Their corrosion rate is much higher as compared to other metals and it grows rapidly with increasing melt temperature. The temperature growth by 200 deg C results in an increase in the corrosion rate almost by an order. The potentials of lanthanum- and yttrium electrodes at the instant they are immersed in the melt have more negative values than the potentials of alkali metals under similar conditions

  3. Partition Model-Based 99mTc-MAA SPECT/CT Predictive Dosimetry Compared with 90Y TOF PET/CT Posttreatment Dosimetry in Radioembolization of Hepatocellular Carcinoma: A Quantitative Agreement Comparison.

    Science.gov (United States)

    Gnesin, Silvano; Canetti, Laurent; Adib, Salim; Cherbuin, Nicolas; Silva Monteiro, Marina; Bize, Pierre; Denys, Alban; Prior, John O; Baechler, Sebastien; Boubaker, Ariane

    2016-11-01

    90 Y-microsphere selective internal radiation therapy (SIRT) is a valuable treatment in unresectable hepatocellular carcinoma (HCC). Partition-model predictive dosimetry relies on differential tumor-to-nontumor perfusion evaluated on pretreatment 99m Tc-macroaggregated albumin (MAA) SPECT/CT. The aim of this study was to evaluate agreement between the predictive dosimetry of 99m Tc-MAA SPECT/CT and posttreatment dosimetry based on 90 Y time-of-flight (TOF) PET/CT. We compared the 99m Tc-MAA SPECT/CT results for 27 treatment sessions (25 HCC patients, 41 tumors) with 90 Y SIRT (7 glass spheres, 20 resin spheres) and the posttreatment 90 Y TOF PET/CT results. Three-dimensional voxelized dose maps were computed from the 99m Tc-MAA SPECT/CT and 90 Y TOF PET/CT data. Mean absorbed dose ([Formula: see text]) was evaluated to compute the predicted-to-actual dose ratio ([Formula: see text]) in tumor volumes (TVs) and nontumor volumes (NTVs) for glass and resin spheres. The Lin concordance ([Formula: see text]) was used to measure accuracy ([Formula: see text]) and precision (ρ). Administered activity ranged from 0.8 to 1.9 GBq for glass spheres and from 0.6 to 3.4 GBq for resin spheres, and the respective TVs ranged from 2 to 125 mL and from 6 to 1,828 mL. The mean dose [Formula: see text] was 240 Gy for glass and 122 Gy for resin in TVs and 72 Gy for glass and 47 Gy for resin in NTVs. [Formula: see text] was 1.46 ± 0.58 (0.65-2.53) for glass and 1.16 ± 0.41 (0.54-2.54) for resin, and the respective values for [Formula: see text] were 0.88 ± 0.15 (0.56-1.00) and 0.86 ± 0.2 (0.58-1.35). DR variability was substantially lower in NTVs than in TVs. The Lin concordance between [Formula: see text] and [Formula: see text] (resin) was significantly better for tumors larger than 150 mL than for tumors 150 mL or smaller ([Formula: see text] = 0.93 and [Formula: see text] = 0.95 vs. [Formula: see text] = 0.57 and [Formula: see text] = 0.93; P < 0.05). In 90 Y radioembolization

  4. Hydrothermal synthesis and formation mechanism of hexagonal yttrium hydroxide fluoride nanobundles

    International Nuclear Information System (INIS)

    Tian, Li; Sun, QiLiang; Zhao, RuiNi; He, HuiLin; Xue, JianRong; Lin, Jun

    2013-01-01

    Graphical abstract: The formation of yttrium hydroxide fluorides nanobundles can be expressed as a precipitation transformation from cubic NaYF 4 to hexagonal NaYF 4 and to hexagonal Y(OH) 2.02 F 0.98 owing to ion exchange. - Highlights: • Novel Y(OH) 2.02 F 0.98 nanobundles have been successfully prepared by hydrothermal method. • The branched nanobundles composed of numerous oriented-attached nanoparticles has been studied. • The growth mechanism is proposed to be ion exchange and precipitation transformation. - Abstract: This article presents the fabrication of hexagonal yttrium hydroxide fluoride nanobundles via one-pot hydrothermal process, using yttrium nitrate, sodium hydroxide and ammonia fluoride as raw materials to react in propanetriol solvent. The X-ray diffraction pattern clearly reveals that the grown product is pure yttrium hydroxide fluoride, namely Y(OH) 2.02 F 0.98 . The morphology and microstructure of the synthesized product is testified to be nanobundles composed of numerous oriented-attached nanoparticles as observed from the field emission scanning electron microscopy (FESEM). The chemical composition was analyzed by the energy dispersive spectrum (EDS), confirming the phase transformation of the products which was clearly consistent with the result of XRD analysis. It is proposed that the growth of yttrium hydroxide fluoride nanobundles be attributed to ion exchange and precipitation transformation

  5. Lanthanoid and yttrium tellurates

    Energy Technology Data Exchange (ETDEWEB)

    Gonalez, C G; Guedes de Carvalho, R A [Faculdade de Engenharia, Porto (Portugal). Centro de Engenharia Quimica

    1978-05-01

    Preparation in aqueous medium of all the lanthanoid (except Ce and Pm) and yttrium tellurates is described. Chemical analyses, solubilities at 25/sup 0/C in water and thermograms of all the products prepared were determined. X-ray diffractograms and DTA and DTG curves of La, Gd and Yb tellurates were obtained and commented. Partial volatilization of lanthanoid is observed in the thermal analysis of tellurates.

  6. Thermal analysis of iron hydroxide microspheres

    International Nuclear Information System (INIS)

    Turcanu, C.N.; Cornescu, M.

    1979-03-01

    The thermal treatment is an important step in the preparative technology of the iron oxids microspheres with well established mechanical, physical and chemical characteristics. The first indications on the heating procedure have been obtained from the thermal analysis on iron hydroxide microspheres prepared by the support precipitation and internal gelification methods. (author)

  7. New hydrotalcite-like compounds containing yttrium

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, J.M.; Barriga, C.; Ulibarri, M.A. [Universidad de Cordoba (Spain)] [and others

    1997-01-01

    The synthesis of hydrotalcite-type compounds containing yttrium was carried out by the coprecipitation of Mg(II), Al(III), and Y(III) cations at 60 degrees C with strong alkaline solutions. Thermal treatments were applied and changes studied.

  8. Nanomechanics of biocompatible hollow thin-shell polymer microspheres.

    Science.gov (United States)

    Glynos, Emmanouil; Koutsos, Vasileios; McDicken, W Norman; Moran, Carmel M; Pye, Stephen D; Ross, James A; Sboros, Vassilis

    2009-07-07

    The nanomechanical properties of biocompatible thin-shell hollow polymer microspheres with approximately constant ratio of shell thickness to microsphere diameter were measured by nanocompression tests in aqueous conditions. These microspheres encapsulate an inert gas and are used as ultrasound contrast agents by releasing free microbubbles in the presence of an ultrasound field as a result of free gas leakage from the shell. The tests were performed using an atomic force microscope (AFM) employing the force-distance curve technique. An optical microscope, on which the AFM was mounted, was used to guide the positioning of tipless cantilevers on top of individual microspheres. We performed a systematic study using several cantilevers with spring constants varying from 0.08 to 2.3 N/m on a population of microspheres with diameters from about 2 to 6 microm. The use of several cantilevers with various spring constants allowed a systematic study of the mechanical properties of the microsphere thin shell at different regimes of force and deformation. Using thin-shell mechanics theory for small deformations, the Young's modulus of the thin wall material was estimated and was shown to exhibit a strong size effect: it increased as the shell became thinner. The Young's modulus of thicker microsphere shells converged to the expected value for the macroscopic bulk material. For high applied forces, the force-deformation profiles showed a reversible and/or irreversible nonlinear behavior including "steps" and "jumps" which were attributed to mechanical instabilities such as buckling events.

  9. Simplified method for the determination of strontium-90 in large amounts of bone-ash; Methode simplifiee de dosage du strontium 90 sur des quantites importantes de cendres d'os

    Energy Technology Data Exchange (ETDEWEB)

    Patti, F; Jeanmaire, L [Commissariat a l' Energie Atomique, Fontenay-aux-roses (France). Centre d' Etudes Nucleaires

    1966-06-01

    The principle of the determination is based on a 3-step process: 1) concentrating the strontium by attacking the ash with nitric acid; 2) elimination of residual phosphoric ions by a double precipitation of strontium oxalate; and 3) extraction of yttrium 90, counted in the oxalate form. The advantages of the method: -) using simple techniques it makes it possible to process 50 g of ash; -) the initial concentration of strontium considerably reduces the volume of the solutions as well as the size of precipitates handled. Fuming nitric acid is used in a specially designed burette. (authors) [French] Le principe du dosage repos sur un procede en 3 etapes: 1) Concentration du strontium par une attaque nitrique des cendres; 2) Elimination des ions phosphoriques restants par une double precipitation de l'oxalate de strontium. 3) Extraction de l'yttrium 90, compte sous forme d'oxalate. Interet de la methode: dans des conditions techniques simples, elle permet le traitement de 50 g de cendres d'os; la concentration initiale du strontium reduit notablement le volume des solutions ainsi que l'importance des precipites manipules. L'acide nitrique fumant est utilise par l'intermediaire d'une burette specialement concue a cet effet.

  10. Magnetic structure of holmium-yttrium superlattices

    DEFF Research Database (Denmark)

    Jehan, D.A.; McMorrow, D.F.; Cowley, R.A.

    1993-01-01

    We present the results of a study of the chemical and magnetic structures of a series of holmium-yttrium superlattices and a 5000 angstrom film of holmium, all grown by molecular-beam epitaxy. By combining the results of high-resolution x-ray diffraction with detailed modeling, we show...... that the superlattices have high crystallographic integrity: the structural coherence length parallel to the growth direction is typically almost-equal-to 2000 angstrom, while the interfaces between the two elements are well defined and extend over approximately four lattice planes. The magnetic structures were...... determined using neutron-scattering techniques. The moments on the Ho3+ ions in the superlattices form a basal-plane helix. From an analysis of the superlattice structure factors of the primary magnetic satellites, we are able to determine separately the contributions made by the holmium and yttrium...

  11. Electrochemical separation of 90-yttrium in the electrochemical 90Sr/90Y generator and its use for radiolabelling of DOTA-conjugated somatostatin analog [DOTA0, Tyr3] octreotate

    Directory of Open Access Journals (Sweden)

    Petrović Đorđe Ž.

    2012-01-01

    Full Text Available Radiopharmaceuticals based on 90Y are widely used in the treatment of malignant deseases. In order to meet the requirements for their future application, a 90Sr/90Y generator was developed and 90Y eluted from this locally produced generator was used for the radiolabelling of the DOTA-conjugated somatostatin analog [DOTA0,Tyr3] octreotate and the preparation of [90Y-DOTA0,Tyr3] octreotate (90Y-DOTATATE for peptide receptore radionuclide therapy. 90Sr/90Y generator was based on the electrochemical separation of 90Y from 90Sr in a two-cycle electrolysis procedure. Three electrode cells were used to perform both electrolyses. In both cycles, working electrodes were kept on constant potential. The pH of the solution was adjusted to 2.7 of the value before the electrolyses. The radionuclidic purity of the 90Y solution was analysed by ITLC and extraction paper chromatography. The labelling of peptide (100 mg DOTATATE with 90YCl3 was performed at 95°C for 30 minutes. Radiochemical purity was determined by HPLC and chromatographic separation, using a solid SepPak C-18 column. Results obtained confirmed the efficiency of our electrochemical separation technique and quality control methods for 90Y. The achieved efficiency of the 90Sr/90Y generator above 96% of the theoretical value represents a good basis for the further development of this generator. The labelling of the DOTATATE with 90Y exhibited a high efficiency, too: there was less than 1% of 90Y3+in the 90Y-DOTATATE.

  12. Thermal expansion at low temperatures of glass-ceramics and glasses

    Energy Technology Data Exchange (ETDEWEB)

    White, G K [National Measurement Lab., Sydney (Australia)

    1976-08-01

    The linear thermal expansion coefficient, ..cap alpha.., has been measured from 2 to 32 K and from 55 to 90 K for a machineable glass-ceramic, an 'ultra-low expansion' titanium silicate glass (Corning ULE), and ceramic glasses (Cer-Vit and Zerodur), and for glassy carbon. ..cap alpha.. is negative for the ultra-low expansion materials below 100 K, as for pure vitreous silica. Comparative data are reported for ..cap alpha..-quartz , ..cap alpha..-cristobalite, common opal, and vitreous silica.

  13. Separation of Yttrium from Rare Earth Concentrates in Fractional Hydroxide Precipitation

    International Nuclear Information System (INIS)

    Tri Handini; Purwoto; Mulyono

    2007-01-01

    Yttrium has been separated from rare earth concentrates by precipitation in fractional hydroxide using urea. The purpose of this research is to increase the yttrium rate resulting from the sedimentary process through separation of yttrium from other rare earth in fractional hydroxide precipitation using urea. In this research, we study the process variable of the concentration of urea, the ratio of feed volume to condensation volume of urea, as well as the temperature. Determination analysis of the rare earth rate is conducted using an X-ray spectrometer. The best result Y=92.89 % is obtained at a concentration of urea of 50 %, a level of precipitation of 3 times, and a temperature of 80°C. (author)

  14. Preparing microspheres of actinide nitrides from carbon containing oxide sols

    International Nuclear Information System (INIS)

    Triggiani, L.V.

    1975-01-01

    A process is given for preparing uranium nitride, uranium oxynitride, and uranium carboxynitride microspheres and the microspheres as compositions of matter. The microspheres are prepared from carbide sols by reduction and nitriding steps. (Official Gazette)

  15. Recovery of yttrium from fluorescent powder of cathode ray tube, CRT: Zn removal by sulphide precipitation

    International Nuclear Information System (INIS)

    Innocenzi, Valentina; De Michelis, Ida; Ferella, Francesco; Beolchini, Francesca; Kopacek, Bernd; Vegliò, Francesco

    2013-01-01

    Highlights: • Treatment of fluorescent powder of CRT waste. • Factorial experimental designs to study acid leaching of fluorescent powder and the purification of leach liquors. • Recover of yttrium by precipitation using oxalic acid. • Suitable flowsheet to recover yttrium from fluorescent powder. - Abstract: This work is focused on the recovery of yttrium and zinc from fluorescent powder of cathode ray tube (CRT). Metals are extracted by sulphuric acid in the presence of hydrogen peroxide. Leaching tests are carried out according to a 2 2 full factorial plan and the highest extraction yields for yttrium and zinc equal to 100% are observed under the following conditions: 3 M of sulphuric acid, 10% v/v of H 2 O 2 concentrated solution at 30% v/v, 10% w/w pulp density, 70 °C and 3 h of reaction. Two series of precipitation tests for zinc are carried out: a 2 2 full factorial design and a completely randomized factorial design. In these series the factors investigated are pH of solution during the precipitation and the amount of sodium sulphide added to precipitate zinc sulphide. The data of these tests are used to describe two empirical mathematical models for zinc and yttrium precipitation yields by regression analysis. The highest precipitation yields for zinc are obtained under the following conditions: pH equal to 2–2.5% and 10–12% v/v of Na 2 S concentrated solution at 10% w/v. In these conditions the coprecipitation of yttrium is of 15–20%. Finally further yttrium precipitation experiments by oxalic acid on the residual solutions, after removing of zinc, show that yttrium could be recovered and calcined to obtain the final product as yttrium oxide. The achieved results allow to propose a CRT recycling process based on leaching of fluorescent powder from cathode ray tube and recovery of yttrium oxide after removing of zinc by precipitation. The final recovery of yttrium is 75–80%

  16. Recovery of yttrium from fluorescent powder of cathode ray tube, CRT: Zn removal by sulphide precipitation

    Energy Technology Data Exchange (ETDEWEB)

    Innocenzi, Valentina, E-mail: valentina.innocenzi1@univaq.it [Department of Industrial Engineering and Information and Economy, University of L’Aquila, Via Giovanni Gronchi n.18, Nucleo Ind.le di Pile, 67100 L’Aquila (Italy); De Michelis, Ida; Ferella, Francesco [Department of Industrial Engineering and Information and Economy, University of L’Aquila, Via Giovanni Gronchi n.18, Nucleo Ind.le di Pile, 67100 L’Aquila (Italy); Beolchini, Francesca [Department of Marine Sciences, Polytechnic Institute of Marche, Via Brecce Bianche, 60131 Ancona (Italy); Kopacek, Bernd [SAT, Austrian Society for Systems Engineering and Automation, Gurkasse 43/2, A-1140 Vienna (Austria); Vegliò, Francesco [Department of Industrial Engineering and Information and Economy, University of L’Aquila, Via Giovanni Gronchi n.18, Nucleo Ind.le di Pile, 67100 L’Aquila (Italy)

    2013-11-15

    Highlights: • Treatment of fluorescent powder of CRT waste. • Factorial experimental designs to study acid leaching of fluorescent powder and the purification of leach liquors. • Recover of yttrium by precipitation using oxalic acid. • Suitable flowsheet to recover yttrium from fluorescent powder. - Abstract: This work is focused on the recovery of yttrium and zinc from fluorescent powder of cathode ray tube (CRT). Metals are extracted by sulphuric acid in the presence of hydrogen peroxide. Leaching tests are carried out according to a 2{sup 2} full factorial plan and the highest extraction yields for yttrium and zinc equal to 100% are observed under the following conditions: 3 M of sulphuric acid, 10% v/v of H{sub 2}O{sub 2} concentrated solution at 30% v/v, 10% w/w pulp density, 70 °C and 3 h of reaction. Two series of precipitation tests for zinc are carried out: a 2{sup 2} full factorial design and a completely randomized factorial design. In these series the factors investigated are pH of solution during the precipitation and the amount of sodium sulphide added to precipitate zinc sulphide. The data of these tests are used to describe two empirical mathematical models for zinc and yttrium precipitation yields by regression analysis. The highest precipitation yields for zinc are obtained under the following conditions: pH equal to 2–2.5% and 10–12% v/v of Na{sub 2}S concentrated solution at 10% w/v. In these conditions the coprecipitation of yttrium is of 15–20%. Finally further yttrium precipitation experiments by oxalic acid on the residual solutions, after removing of zinc, show that yttrium could be recovered and calcined to obtain the final product as yttrium oxide. The achieved results allow to propose a CRT recycling process based on leaching of fluorescent powder from cathode ray tube and recovery of yttrium oxide after removing of zinc by precipitation. The final recovery of yttrium is 75–80%.

  17. Neutron scattering study of yttrium iron garnet

    Science.gov (United States)

    Shamoto, Shin-ichi; Ito, Takashi U.; Onishi, Hiroaki; Yamauchi, Hiroki; Inamura, Yasuhiro; Matsuura, Masato; Akatsu, Mitsuhiro; Kodama, Katsuaki; Nakao, Akiko; Moyoshi, Taketo; Munakata, Koji; Ohhara, Takashi; Nakamura, Mitsutaka; Ohira-Kawamura, Seiko; Nemoto, Yuichi; Shibata, Kaoru

    2018-02-01

    The nuclear and magnetic structure and full magnon dispersions of yttrium iron garnet Y3Fe5O12 have been studied using neutron scattering. The refined nuclear structure is distorted to a trigonal space group of R 3 ¯ . The highest-energy dispersion extends up to 86 meV. The observed dispersions are reproduced by a simple model with three nearest-neighbor-exchange integrals between 16 a (octahedral) and 24 d (tetrahedral) sites, Ja a, Ja d, and Jd d, which are estimated to be 0.00 ±0.05 , -2.90 ±0.07 , and -0.35 ±0.08 meV, respectively. The lowest-energy dispersion below 14 meV exhibits a quadratic dispersion as expected from ferromagnetic magnons. The imaginary part of q -integrated dynamical spin susceptibility χ″(E ) exhibits a square-root energy dependence at low energies. The magnon density of state is estimated from χ″(E ) obtained on an absolute scale. The value is consistent with the single chirality mode for the magnon branch expected theoretically.

  18. Mesoporous metal oxide microsphere electrode compositions and their methods of making

    Science.gov (United States)

    Parans Paranthaman, Mariappan; Bi, Zhonghe; Bridges, Craig A.; Brown, Gilbert M.

    2017-04-11

    Compositions and methods of making are provided for treated mesoporous metal oxide microspheres electrodes. The compositions include microspheres with an average diameter between about 200 nanometers and about 10 micrometers and mesopores on the surface and interior of the microspheres. The methods of making include forming a mesoporous metal oxide microsphere composition and treating the mesoporous metal oxide microspheres by at least annealing in a reducing atmosphere, doping with an aliovalent element, and coating with a coating composition.

  19. Recovery of yttrium from cathode ray tubes and lamps’ fluorescent powders: experimental results and economic simulation

    International Nuclear Information System (INIS)

    Innocenzi, V.; De Michelis, I.; Ferella, F.; Vegliò, F.

    2013-01-01

    Highlights: • Fluorescent powder of lamps. • Fluorescent powder of cathode ray rubes. • Recovery of yttrium from fluorescent powders. • Economic simulation for the processes to recover yttrium from WEEE. - Abstract: In this paper, yttrium recovery from fluorescent powder of lamps and cathode ray tubes (CRTs) is described. The process for treating these materials includes the following: (a) acid leaching, (b) purification of the leach liquors using sodium hydroxide and sodium sulfide, (c) precipitation of yttrium using oxalic acid, and (d) calcinations of oxalates for production of yttrium oxides. Experimental results have shown that process conditions necessary to purify the solutions and recover yttrium strongly depend on composition of the leach liquor, in other words, whether the powder comes from treatment of CRTs or lamp. In the optimal experimental conditions, the recoveries of yttrium oxide are about 95%, 55%, and 65% for CRT, lamps, and CRT/lamp mixture (called MIX) powders, respectively. The lower yields obtained during treatments of MIX and lamp powders are probably due to the co-precipitation of yttrium together with other metals contained in the lamps powder only. Yttrium loss can be reduced to minimum changing the experimental conditions with respect to the case of the CRT process. In any case, the purity of final products from CRT, lamps, and MIX is greater than 95%. Moreover, the possibility to treat simultaneously both CRT and lamp powders is very important and interesting from an industrial point of view since it could be possible to run a single plant treating fluorescent powder coming from two different electronic wastes

  20. In vitro Evaluation of Nateglinide-Loaded Microspheres Formulated ...

    African Journals Online (AJOL)

    Keywords: Nateglinide, Microspheres, Micromeritics, Drug release, Ionic ... Oral drug delivery systems (DDS) are commonly divided into immediate release and modified release systems. ..... Albumin Microspheres for Potential Intramuscular.