  1. Light emission efficiency and imaging properties of YAP:Ce granular phosphor screens

    International Nuclear Information System (INIS)

    Kalivas, N.; Valais, I.; Nikolopoulos, D.; Konstantinidis, A.; Cavouras, D.; Kandarakis, I.; Gaitanis, A.; Nomicos, C.D.; Panayiotakis, G.

    2007-01-01

    Phosphor materials are used in medical imaging combined with radiographic film or other photodetectors. Cerium (Ce 3+ ) -doped scintillators are of particular interest for medical imaging, because of their very fast response. YAP:Ce scintillator-based image detectors have already been evaluated in single-crystal form and under conditions of positron emission tomography and synchrotron or γ-ray irradiation. Furthermore, YAP:Ce phosphor has been evaluated in conjunction with radiographic films. The present work reports experimental and theoretical data concerning the light output absolute luminescence efficiency (AE) of the YAP:Ce screens under irradiation conditions employed in medical X-ray projection imaging (i.e., in diagnostic radiology). projection imaging (i.e., in diagnostic radiology). YAP:Ce phosphor screens with surface densities ranging between 53 and 110 mg/cm 2 were prepared by sedimentation on fused silica substrates in our laboratory. The resulted surface density of the screens was determined by dividing the phosphor mass deposited on the screen surface with the area of the surface. Additionally this work addresses the imaging performance of YAP:Ce by estimation of the detective quantum efficiency (DQE), i.e., the square of the signal to noise ratio transfer. Absolute efficiency was found to decrease with X-ray tube voltage for for YAP:Ce phosphor. The highest experimental efficiency was obtained for the 53.7 mg/cm 2 and 88.0 mg/cm 2 YAP:Ce screens. The highest DQE value was found for the 88.0 mg/cm 2 screen irradiated at 60 kVp. (orig.)

  2. Imaging properties of cerium doped Yttrium Aluminum Oxide (YAP:Ce) powder scintillating screens under X-ray excitation

    Energy Technology Data Exchange (ETDEWEB)

    Kalivas, N. [Greek Atomic Energy Commission, 15310 Ag. Paraskevi, P.O. Box 60092 (Greece); Valais, I. [Department of Medical Physics, Medical School, University of Patras, 26500 Patras (Greece)]|[Department of Medical Instruments Technology, Technological Educational Institution of Athens, Ag. Spyridonos Street, Aigaleo, 12210 Athens (Greece); Salemis, G.; Karagiannis, C.; Konstantinidis, A.; Nikolopoulos, D. [Department of Medical Instruments Technology, Technological Educational Institution of Athens, Ag. Spyridonos Street, Aigaleo, 12210 Athens (Greece); Loudos, G.; Sakelios, N.; Karakatsanis, N.; Nikita, K. [Department of Electrical and Computer Engineering, National Technical University of Athens, 9 Iroon Polytechniou, 15780 Zografos (Greece); Gayshan, V.L.; Gektin, A.V. [Institute of Scintillation Materials, Lenin Avenue 60, 310072 Kharkov (Ukraine); Sianoudis, I. [Department of Physics, Chemistry and Materials Technology, Technological Educational Institution of Athens, Aigaleo, 12210 Athens (Greece); Giokaris, N. [Physics Department National Capodistrian University of Athens, Panepistimioupolis Ilisia, 15771 Athens (Greece)]|[Institute of Accelerating Systems and Applications, P.O. Box 17214, 10024 Athens (Greece); Nomicos, C.D. [Department of Electronics, Technological Educational Institution of Athens, Aigaleo, 12210 Athens (Greece); Dimitropoulos, N. [Department of Medical Imaging, ' Euromedica' Medical Center, Mesogeion 2-4, 11527 Athens (Greece); Cavouras, D. [Department of Medical Instruments Technology, Technological Educational Institution of Athens, Ag. Spyridonos Street, Aigaleo, 12210 Athens (Greece); Panayiotakis, G. [Department of Medical Physics, Medical School, University of Patras, 26500 Patras (Greece); Kandarakis, I. [Department of Medical Instruments Technology, Technological Educational Institution of Athens, Ag. Spyridonos Street, Aigaleo, 12210 Athens (Greece)]. E-mail: kandarakis@teiath.gr

    2006-12-20

    The aim of the present study was to evaluate the imaging performance of YAP:Ce powder scintillating screens under exposure conditions employed in diagnostic radiology (50-140 kV). Various screens were prepared in our laboratory from YAP: Ce powder (Phosphor Technology, Ltd.), with coating thickness ranging from 53 to 110 mg/cm{sup 2}. The imaging performance of the screens was assessed by experimental determination of the modulation transfer function (MTF) and the noise transfer function (NTF). MTF was determined by the edge spread function (ESF) method while NTF was estimated by noise power spectrum (NPS) measurements after uniform screen irradiation. In addition, parameters related to overall image quality, such as the signal-to-noise ratio transfer (MTF/NTF), were estimated. MTF curves were affected by the beam hardening effects caused by the patient simulating 20 mm thick aluminum phantom. Under these conditions MTF values were found to increase with the mean X-ray photon energy. A similar effect was observed for NTF curves. Results were compared with data obtained on CsI:Tl scintillator. Taking into consideration the very fast response of YAP:Ce, these data may be of interest in designing X-ray imaging detectors.

  3. Radon gamma-ray spectrometry with YAP:Ce scintillator

    CERN Document Server

    Plastino, W; De Notaristefani, F

    2002-01-01

    The detection properties of a YAP:Ce scintillator (YAlO sub 3 :Ce crystal) optically coupled to a Hamamatsu H5784 photomultiplier with standard bialkali photocathode have been analyzed. In particular, the application to radon and radon-daughters gamma-ray spectrometry was investigated. The crystal response has been studied under severe extreme conditions to simulate environments of geophysical interest, particularly those found in geothermal and volcanic areas. Tests in water up to a temperature of 100 deg.C and in acids solutions such as HCl (37%), H sub 2 SO sub 4 (48%) and HNO sub 3 (65%) have been performed. The measurements with standard radon sources provided by the National Institute for Metrology of Ionizing Radiations (ENEA) have emphasized the non-hygroscopic properties of the scintillator and a small dependence of the light yield on temperature and HNO sub 3. The data collected in this first step of our research have pointed out that the YAP:Ce scintillator can allow high response stability for rad...

  4. YAP:Ce and CsI(Tl) detectors for dielectronic recombination experiment at the CSRm

    International Nuclear Information System (INIS)

    Wen, W.Q.; Ma, X.; Xu, W.Q.; Meng, L.J.; Zhu, X.L.; Gao, Y.; Wang, S.L.; Zhang, P.J.; Zhao, D.M.; Liu, H.P.; Zhu, L.F.; Yang, X.D.; Li, J.; Ma, X.M.; Yan, T.L.; Yang, J.C.; Yuan, Y.J.; Xia, J.W.; Xu, H.S.; Xiao, G.Q.

    2013-01-01

    Highlights: • YAP:Ce and CsI(Tl) scintillation detectors are developed to detect heavy ions at the storage ring. • A high count rate of ∼10 7 s −1 is obtained with the YAP:Ce detector for heavy ion detection. • YAP:Ce detector shows good performance for DR experiment with 3.7 MeV/u 112 Sn 35+ . -- Abstract: The storage ring CSRm in Lanzhou provides good possibilities for electron-ion collision studies with cooled ion beams. To carry on the recombination experiment at the CSRm, a scintillation detector CsI(Tl) to detect the recombined ions was developed and tested. In addition, a YAP:Ce detector has been developed and installed at CSRm and capability of handling a high count rate of ∼10 7 s −1 has been obtained which is sufficient for the future dielectronic recombination experiment at the CSRm. The comparison of the characteristics of these two detectors is presented

  5. YAP(Ce) crystal characterization with proton beam up to 60 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Randazzo, N. [Istituto Nazionale di Fisica Nucleare, Sezione di Catania (I), Via S. Sofia, 64-I-95123 Catania (Italy)], E-mail: nunzio.randazzo@ct.infn.it; Sipala, V.; Aiello, S. [Istituto Nazionale di Fisica Nucleare, Sezione di Catania (I), Via S. Sofia, 64-I-95123 Catania (Italy); Lo Presti, D. [Istituto Nazionale di Fisica Nucleare, Sezione di Catania (I), Via S. Sofia, 64-I-95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Universita di Catania, Catania (Italy); Cirrone, G.A.P.; Cuttone, G.; Di Rosa, F. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud (Italy)

    2008-02-21

    A YAP(Ce) crystal was characterized with a proton beam up to 60 MeV. Tests were performed to investigate the possibility of using this detector as a proton calorimeter. The size of the crystal was chosen so that the proton energy is totally lost inside the medium. The authors propose to use the YAP(Ce) crystal in medical applications for proton therapy. In particular, in proton computed tomography (pCT) project it is necessary as a calorimeter in order to measure the proton residual energy after the phantom. Energy resolution, linearity, and light yield were measured in the Laboratori Nazionali del Sud with the CATANA proton beam [ (http://www.lns.infn.it/CATANA/CATANA)] and the results are shown in this paper. The crystal shows a good resolution (3% at 60 MeV proton beam) and it shows good linearity for different proton beam energies (1% at 30-60 MeV energy range). The crystal performances confirm that the YAP(Ce) crystal represents a good solution for these kinds of application.

  6. YAP(Ce) crystal characterization with proton beam up to 60 MeV

    International Nuclear Information System (INIS)

    Randazzo, N.; Sipala, V.; Aiello, S.; Lo Presti, D.; Cirrone, G.A.P.; Cuttone, G.; Di Rosa, F.

    2008-01-01

    A YAP(Ce) crystal was characterized with a proton beam up to 60 MeV. Tests were performed to investigate the possibility of using this detector as a proton calorimeter. The size of the crystal was chosen so that the proton energy is totally lost inside the medium. The authors propose to use the YAP(Ce) crystal in medical applications for proton therapy. In particular, in proton computed tomography (pCT) project it is necessary as a calorimeter in order to measure the proton residual energy after the phantom. Energy resolution, linearity, and light yield were measured in the Laboratori Nazionali del Sud with the CATANA proton beam [ (http://www.lns.infn.it/CATANA/CATANA)] and the results are shown in this paper. The crystal shows a good resolution (3% at 60 MeV proton beam) and it shows good linearity for different proton beam energies (1% at 30-60 MeV energy range). The crystal performances confirm that the YAP(Ce) crystal represents a good solution for these kinds of application

  7. YAP(Ce) crystal characterization with proton beam up to 60 MeV

    Science.gov (United States)

    Randazzo, N.; Sipala, V.; Aiello, S.; Lo Presti, D.; Cirrone, G. A. P.; Cuttone, G.; Di Rosa, F.

    2008-02-01

    A YAP(Ce) crystal was characterized with a proton beam up to 60 MeV. Tests were performed to investigate the possibility of using this detector as a proton calorimeter. The size of the crystal was chosen so that the proton energy is totally lost inside the medium. The authors propose to use the YAP(Ce) crystal in medical applications for proton therapy. In particular, in proton computed tomography (pCT) project it is necessary as a calorimeter in order to measure the proton residual energy after the phantom. Energy resolution, linearity, and light yield were measured in the Laboratori Nazionali del Sud with the CATANA proton beam [ http://www.lns.infn.it/CATANA/CATANA] and the results are shown in this paper. The crystal shows a good resolution (3% at 60 MeV proton beam) and it shows good linearity for different proton beam energies (1% at 30-60 MeV energy range). The crystal performances confirm that the YAP(Ce) crystal represents a good solution for these kinds of application.

  8. Scintillation response of BaF2 and YAlO3:Ce (YAP:Ce) to energetic ions

    International Nuclear Information System (INIS)

    Slunga, E.; Cederwall, B.; Ideguchi, E.; Kerek, A.; Klamra, W.; Marel, J. van der; Novak, D.; Norlin, L.-O.

    2001-01-01

    The scintillation response of BaF 2 and YAP:Ce to protons, α particles, 16 O and 28 Si ions in the 5-30 MeV range has been investigated. The ratio between the fast and slow parts of the scintillator signal for BaF 2 has been used to separate protons, α particles and heavier ions, and the dependence of this ratio on the particle energy has been studied. The time constants and intensities of the two components of the YAP:Ce signal were measured, as were the time constant and intensity of the weak component of the slow part of the BaF 2 signal. Furthermore, the dependence of the light yield on the particle energy has been investigated for both BaF 2 and YAP:Ce

  9. Studies of scintillation light nonproportionality of ZnSe(Te), CsI(Tl) and YAP(Ce) crystals using heavy ions

    CERN Document Server

    Klamra, W; Kapusta, M; Kérek, A; Moszynski, M; Norlin, L O; Novák, D; Possnert, G

    2002-01-01

    The scintillation light yield for ZnSe(Te), CsI(Tl) and YAP(Ce) crystals have been studied with alpha particles, sup 1 sup 2 C and sup 8 sup 1 Br in the energy region 2.8-42.2 MeV. A nonproportional behavior was observed, mostly pronounced for alpha particles on YAP(Ce). The results are understood in terms of delta-rays effect.

  10. New Imaging Operation Scheme at VLTI

    Science.gov (United States)

    Haubois, Xavier

    2018-04-01

    After PIONIER and GRAVITY, MATISSE will soon complete the set of 4 telescope beam combiners at VLTI. Together with recent developments in the image reconstruction algorithms, the VLTI aims to develop its operation scheme to allow optimized and adaptive UV plane coverage. The combination of spectro-imaging instruments, optimized operation framework and image reconstruction algorithms should lead to an increase of the reliability and quantity of the interferometric images. In this contribution, I will present the status of this new scheme as well as possible synergies with other instruments.

  11. Operating radiographic image intensifier tube

    International Nuclear Information System (INIS)

    Marche, E.; Girard, A.; Barjot, D.; Deon, J.M.; Lacoste, Y.

    1996-01-01

    The intensifier tube operation method involves a voltage supply (U) which is placed across two transistors (Q 1, Q 2) in series. The voltage driver to the photocathode (PC) is the centre point between the two transistors. A switching command is applied to a logic circuit (CL). The logic circuit drives two light emitting diodes (DEL1, DEL2) when a threshold light level is exceeded, each LED triggers an optical switch (TR1, TR2). The switches change the state of the transistors. Switching the upper transistor on and the lower transistor off applies a voltage to the photocathode. Switching off the upper transistor and on the lower transistor blocks the high voltage and sets the photocathode to zero. The advantage of this device is that it involves circuit regulator which is less complex, it has cheaper and more easily implemented transient protection and has reduced sizes. (authors). 10 figs

  12. Image denoising using the squared eigenfunctions of the Schrodinger operator

    KAUST Repository

    Kaisserli, Zineb; Laleg-Kirati, Taous-Meriem

    2015-01-01

    This study introduces a new image denoising method based on the spectral analysis of the semi-classical Schrodinger operator. The noisy image is considered as a potential of the Schrodinger operator, and the denoised image is reconstructed using the discrete spectrum of this operator. First results illustrating the performance of the proposed approach are presented and compared to the singular value decomposition method.

  13. Image denoising using the squared eigenfunctions of the Schrodinger operator

    KAUST Repository

    Kaisserli, Zineb

    2015-02-02

    This study introduces a new image denoising method based on the spectral analysis of the semi-classical Schrodinger operator. The noisy image is considered as a potential of the Schrodinger operator, and the denoised image is reconstructed using the discrete spectrum of this operator. First results illustrating the performance of the proposed approach are presented and compared to the singular value decomposition method.

  14. GALILEO NIMS SPECTRAL IMAGE CUBES: JUPITER OPERATIONS

    Data.gov (United States)

    National Aeronautics and Space Administration — The natural form of imaging spectrometer data is the spectral image cube. It is normally in band sequential format, but has a dual nature. It is a series of 'images'...

  15. GALILEO NIMS SPECTRAL IMAGE TUBES: JUPITER OPERATIONS

    Data.gov (United States)

    National Aeronautics and Space Administration — The natural form of imaging spectrometer data is the spectral image cube. It is normally in band sequential format, but has a dual nature. It is a series of 'images'...

  16. Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery.

    Science.gov (United States)

    Beerekamp, M S H; Backes, M; Schep, N W L; Ubbink, D T; Luitse, J S; Schepers, T; Goslings, J C

    2017-12-01

    Previous studies demonstrated that intra-operative fluoroscopic 3D-imaging (3D-imaging) in calcaneal fracture surgery is promising to prevent revision surgery and save costs. However, these studies limited their focus to corrections performed after 3D-imaging, thereby neglecting corrections after intra-operative fluoroscopic 2D-imaging (2D-imaging). The aim of this study was to assess the effects of additional 3D-imaging on intra-operative corrections, peri-operative imaging used, and patient-relevant outcomes compared to 2D-imaging alone. In this before-after study, data of adult patients who underwent open reduction and internal fixation (ORIF) of a calcaneal fracture between 2000 and 2014 in our level-I Trauma center were collected. 3D-imaging (BV Pulsera with 3D-RX, Philips Healthcare, Best, The Netherlands) was available as of 2007 at the surgeons' discretion. Patient and fracture characteristics, peri-operative imaging, intra-operative corrections and patient-relevant outcomes were collected from the hospital databases. Patients in whom additional 3D-imaging was applied were compared to those undergoing 2D-imaging alone. A total of 231 patients were included of whom 107 (46%) were operated with the use of 3D-imaging. No significant differences were found in baseline characteristics. The median duration of surgery was significantly longer when using 3D-imaging (2:08 vs. 1:54 h; p = 0.002). Corrections after additional 3D-imaging were performed in 53% of the patients. However, significantly fewer corrections were made after 2D-imaging when 3D-imaging was available (Risk difference (RD) -15%; 95% Confidence interval (CI) -29 to -2). Peri-operative imaging, besides intra-operative 3D-imaging, and patient-relevant outcomes were similar between groups. Intra-operative 3D-imaging provides additional information resulting in additional corrections. Moreover, 3D-imaging probably changed the surgeons' attitude to rely more on 3D-imaging, hence a 15%-decrease of

  17. Light response of YAP:Ce and LaBr{sub 3}:Ce scintillators to 4–30 MeV protons for applications to Telescope Proton Recoil neutron spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Cazzaniga, C., E-mail: carlo.cazzaniga@stfc.ac.uk [ISIS Facility, Science and Technology Facilities Council, Rutherford Appleton Laboratory, Didcot OX11 0QX (United Kingdom); Istituto di Fisica del Plasma “P. Caldirola”, Associazione EURATOM-ENEA/CNR, Via Cozzi 53, Milano (Italy); Cremona, A. [Istituto di Fisica del Plasma “P. Caldirola”, Associazione EURATOM-ENEA/CNR, Via Cozzi 53, Milano (Italy); Nocente, M.; Rebai, M.; Rigamonti, D. [Istituto di Fisica del Plasma “P. Caldirola”, Associazione EURATOM-ENEA/CNR, Via Cozzi 53, Milano (Italy); Università degli Studi di Milano-Bicocca, Dipartimento di Fisica, Piazza della Scienza 3, Milano (Italy); Tardocchi, M. [Istituto di Fisica del Plasma “P. Caldirola”, Associazione EURATOM-ENEA/CNR, Via Cozzi 53, Milano (Italy); Croci, G. [Istituto di Fisica del Plasma “P. Caldirola”, Associazione EURATOM-ENEA/CNR, Via Cozzi 53, Milano (Italy); Università degli Studi di Milano-Bicocca, Dipartimento di Fisica, Piazza della Scienza 3, Milano (Italy); Ericsson, G. [Department of Physics and Astronomy, EURATOM-VR Association, Uppsala University, Uppsala (Sweden); Fazzi, A. [Department of Energy of the Politecnico di Milano, via Lambruschini 4, I-20156 Milano (Italy); Hjalmarsson, A. [Department of Physics and Astronomy, EURATOM-VR Association, Uppsala University, Uppsala (Sweden); Mazzocco, M.; Strano, E. [Dipartimento di Fisica e Astronomia, Universitá di Padova, and INFN, Sez. di Padova, I-35131 Padova (Italy); and others

    2016-06-01

    The light response of two thin inorganic scintillators based on YAP:Ce and LaBr{sub 3}:Ce crystals has been measured with protons in the 4–8 MeV energy range at the Uppsala tandem accelerator and in the 8–26 MeV energy range at the Legnaro tandem accelerator. The crystals have been calibrated in situ with {sup 137}Cs and {sup 60}Co γ-ray sources. The relative light yields of protons with respect to gammas have been measured and are here reported to be (96±2)% and (80±2)% for YAP:Ce and LaBr{sub 3}:Ce, respectively. The results open up to the development of a Telescope Proton Recoil spectrometer based on either of the two crystals as alternative to a silicon based spectrometer for applications to high neutron fluxes.

  18. A Novel Image Encryption Algorithm Based on DNA Subsequence Operation

    Directory of Open Access Journals (Sweden)

    Qiang Zhang

    2012-01-01

    Full Text Available We present a novel image encryption algorithm based on DNA subsequence operation. Different from the traditional DNA encryption methods, our algorithm does not use complex biological operation but just uses the idea of DNA subsequence operations (such as elongation operation, truncation operation, deletion operation, etc. combining with the logistic chaotic map to scramble the location and the value of pixel points from the image. The experimental results and security analysis show that the proposed algorithm is easy to be implemented, can get good encryption effect, has a wide secret key's space, strong sensitivity to secret key, and has the abilities of resisting exhaustive attack and statistic attack.

  19. The operation technology of realtime image processing system (Datacube)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Lee, Yong Bum; Lee, Nam Ho; Choi, Young Soo; Park, Soon Yong; Park, Jin Seok

    1997-02-01

    In this project, a Sparc VME-based MaxSparc system, running the solaris operating environment, is selected as the dedicated image processing hardware for robot vision applications. In this report, the operation of Datacube maxSparc system, which is high performance realtime image processing hardware, is systematized. And image flow example programs for running MaxSparc system are studied and analyzed. The state-of-the-arts of Datacube system utilizations are studied and analyzed. For the next phase, advanced realtime image processing platform for robot vision application is going to be developed. (author). 19 refs., 71 figs., 11 tabs.

  20. Research for correction pre-operative MRI images of brain during operation using particle method simulation

    International Nuclear Information System (INIS)

    Shino, Ryosaku; Koshizuka, Seiichi; Sakai, Mikio; Ito, Hirotaka; Iseki, Hiroshi; Muragaki, Yoshihiro

    2010-01-01

    In the neurosurgical procedures, surgeon formulates a surgery plan based on pre-operative images such as MRI. However, the brain is transformed by removal of the affected area. In this paper, we propose a method for reconstructing pre-operative images involving the deformation with physical simulation. First, the domain of brain is identified in pre-operative images. Second, we create particles for physical simulation. Then, we carry out the linear elastic simulation taking into account the gravity. Finally, we reconstruct pre-operative images with deformation according to movement of the particles. We show the effectiveness of this method by reconstructing the pre-operative image actually taken before surgery. (author)

  1. Image enhancement software for underwater recovery operations: User's manual

    Science.gov (United States)

    Partridge, William J.; Therrien, Charles W.

    1989-06-01

    This report describes software for performing image enhancement on live or recorded video images. The software was developed for operational use during underwater recovery operations at the Naval Undersea Warfare Engineering Station. The image processing is performed on an IBM-PC/AT compatible computer equipped with hardware to digitize and display video images. The software provides the capability to provide contrast enhancement and other similar functions in real time through hardware lookup tables, to automatically perform histogram equalization, to capture one or more frames and average them or apply one of several different processing algorithms to a captured frame. The report is in the form of a user manual for the software and includes guided tutorial and reference sections. A Digital Image Processing Primer in the appendix serves to explain the principle concepts that are used in the image processing.

  2. Sub-millimeter planar imaging with positron emitters: EGS4 code simulation and experimental results

    International Nuclear Information System (INIS)

    Bollini, D.; Del Guerra, A.; Di Domenico, G.

    1996-01-01

    Experimental data for Planar Imaging with positron emitters (pulse height, efficiency and spatial resolution) obtained with two matrices of 25 crystals (2 x 2 x 30 mm 3 each) of YAP:Ce coupled with a Position Sensitive PhotoMultiplier (Hamamatsu R2486-06) have been reproduced with high accuracy using the EGS4 code. Extensive simulation provides a detailed description of the performance of this type of detector as a function of the matrix granularity, the geometry of the detector and detection threshold. We present the Monte Carlo simulation and the preliminary experimental results of a prototype planar imaging system made of two matrices, each one consisting of 400 (2 x 2 x 30 mm 3 ) crystals of YAP-Ce

  3. Assessment of the sinus lift operation by magnetic resonance imaging.

    Science.gov (United States)

    Senel, Figen Cizmeci; Duran, Serpil; Icten, Onur; Izbudak, Izlem; Cizmeci, Fulya

    2006-12-01

    Vertical bone loss in edentulous maxillary alveolar processes may necessitate a sinus lift before the placement of dental implants. We have measured and assessed maxillary sinuses meticulously before the operation and evaluated the postoperative results of the operation with magnetic resonance imaging (MRI). Thirteen edentulous maxillary regions in eight patients were included in the study. The patients were examined 1 week before and 3 months after the sinus lift operations using a 1.5 T superconductive MR imager that gave oblique sagittal T2-weighted images with slices 2 mm thick without a gap. The images that were obtained 3 months after the sinus lift operations confirmed that vertical height had increased. We obtained high quality images without any artefacts during a short examination period with a high-resolution scanner. The results showed that it is possible to assess the maxillary sinus before the sinus lift and to evaluate the postoperative results using MRI accurately in three dimensions without the risk of radiation. This makes MRI a suitable alternative to computed tomography (CT).

  4. Chaotic Image Encryption Algorithm Based on Circulant Operation

    Directory of Open Access Journals (Sweden)

    Xiaoling Huang

    2013-01-01

    Full Text Available A novel chaotic image encryption scheme based on the time-delay Lorenz system is presented in this paper with the description of Circulant matrix. Making use of the chaotic sequence generated by the time-delay Lorenz system, the pixel permutation is carried out in diagonal and antidiagonal directions according to the first and second components. Then, a pseudorandom chaotic sequence is generated again from time-delay Lorenz system using all components. Modular operation is further employed for diffusion by blocks, in which the control parameter is generated depending on the plain-image. Numerical experiments show that the proposed scheme possesses the properties of a large key space to resist brute-force attack, sensitive dependence on secret keys, uniform distribution of gray values in the cipher-image, and zero correlation between two adjacent cipher-image pixels. Therefore, it can be adopted as an effective and fast image encryption algorithm.

  5. Digital image monitoring to optimise safe port operation

    CSIR Research Space (South Africa)

    Phelp, D

    2008-11-01

    Full Text Available This paper describes a low cost video system ‘Harbour Watch’, which can be used to support safe port operations, especially in developing countries. Preset digital images are geo-referenced and then archived for later analysis to improve...

  6. Projection Operators and Moment Invariants to Image Blurring

    Czech Academy of Sciences Publication Activity Database

    Flusser, Jan; Suk, Tomáš; Boldyš, Jiří; Zitová, Barbara

    2015-01-01

    Roč. 37, č. 4 (2015), s. 786-802 ISSN 0162-8828 R&D Projects: GA ČR GA13-29225S; GA ČR GAP103/11/1552 Institutional support: RVO:67985556 Keywords : Blurred image * N-fold rotation symmetry * projection operators * image moments * moment invariants * blur invariants * object recognition Subject RIV: JD - Computer Applications, Robotics Impact factor: 6.077, year: 2015 http://library.utia.cas.cz/separaty/2014/ZOI/flusser-0434521.pdf

  7. Operational digital image processing within the Bureau of Land Management

    International Nuclear Information System (INIS)

    Work, E.A.; Story, M.

    1991-01-01

    An overview of the use of operational digital image processing at the U.S. Bureau of Land Management (BLM) is presented. The BLM digital image analysis facility for the processing and analysis of aerial photography and satellite data is described, and its role within the Bureau's operational structure is explained. Attention is given to examples of BLM digital data analysis projects that have utilized Landsat (MSS and TM), NOAA-AVHRR, or SPOT data. These projects include: landcover mapping to assist land use planning or special projects; monitoring of wilderness units to detect unauthorized activities; stratification aid for detailed field inventories; identification/quantification of unauthorized use (agricultural and mineral trespass); and fire fuels mapping and updates. 3 refs

  8. Operational characteristics of pediatric radiology: Image display stations

    International Nuclear Information System (INIS)

    Taira, R.K.

    1987-01-01

    The display of diagnostic images is accomplished in the UCLA Pediatric Radiology Clinical Radiology Imaging System (CRIS) using 3 different types of digital viewing stations. These include a low resolution station with six 512 x 512 monitors, a high resolution station with three 1024 x 1024 monitors, and a very high resolution workstation with two 2048 x 2048 monitors. The display stations provide very basic image processing manipulations including zoom and scroll, contrast enhancement, and contrast reversal. The display stations are driven by a computer system which is dedicated for clinical use. During times when the clinical computer is unavailable (maintenance or system malfunction), the 512 x 512 workstation can be switched to operate from a research PACS system in the UCLA Image Processing Laboratory via a broadband communication network. Our initial clinical implementation involves digital viewing for pediatric radiology conferences. Presentation of inpatient cases use the six monitor 512 x 512 multiple viewing station. Later stages of the clinical implementation involve the use of higher resolution displays for the purpose of primary diagnosis from video displays

  9. Assessment of fusion operators for medical imaging: application to MR images fusion

    International Nuclear Information System (INIS)

    Barra, V.; Boire, J.Y.

    2000-01-01

    We propose in the article to assess the results provided by several fusion operators in the case of T 1 - and T 2 -weighted magnetic resonance images fusion of the brain. This assessment deals with an expert visual inspection of the results and with a numerical analysis of some comparison measures found in the literature. The aim of this assessment is to find the 'best' operator according to the clinical study. This method is here applied to the quantification of brain tissue volumes on a brain phantom, and allows to select a fusion operator in any clinical study where several information is available. (authors)

  10. Post-operative computed tomographic imaging of the shoulder joint

    International Nuclear Information System (INIS)

    Helweg, G.; Zur Nedden, D.; Wicke, K.; Knapp, R.; Oberhauser, A.; Resch, H.; Sperner, G.

    1992-01-01

    Between 1984 and 1990 312 patients underwent surgery for habitual or recurrent shoulder dislocation. Out then, 65 had a post-operative CT examination. This retrospective study was launched to demonstrate the value of CT in post-operative shoulder imaging. In most cases, CT was done using standardised techniques without contrast medium. Except in 4 cases, an intra-articular double-contrast technique was used. Evaluation was focused on 41 cases after implantation of a wedged bone graft in cases of primary or secondary flat glenoid or widening of a small glenoid with cortical consoles and bone block. The results demonstrate the effectiveness of standardised CT technique in that all necessary information concerning stabilisation of the shoulder joint, sufficient implant of bone grafts and assessment of correct inclination after osteotomy were obtained. (orig.)

  11. Multiple-image encryption via lifting wavelet transform and XOR operation based on compressive ghost imaging scheme

    Science.gov (United States)

    Li, Xianye; Meng, Xiangfeng; Yang, Xiulun; Wang, Yurong; Yin, Yongkai; Peng, Xiang; He, Wenqi; Dong, Guoyan; Chen, Hongyi

    2018-03-01

    A multiple-image encryption method via lifting wavelet transform (LWT) and XOR operation is proposed, which is based on a row scanning compressive ghost imaging scheme. In the encryption process, the scrambling operation is implemented for the sparse images transformed by LWT, then the XOR operation is performed on the scrambled images, and the resulting XOR images are compressed in the row scanning compressive ghost imaging, through which the ciphertext images can be detected by bucket detector arrays. During decryption, the participant who possesses his/her correct key-group, can successfully reconstruct the corresponding plaintext image by measurement key regeneration, compression algorithm reconstruction, XOR operation, sparse images recovery, and inverse LWT (iLWT). Theoretical analysis and numerical simulations validate the feasibility of the proposed method.

  12. Active pixel image sensor with a winner-take-all mode of operation

    Science.gov (United States)

    Yadid-Pecht, Orly (Inventor); Fossum, Eric R. (Inventor); Mead, Carver (Inventor)

    2003-01-01

    An integrated CMOS semiconductor imaging device having two modes of operation that can be performed simultaneously to produce an output image and provide information of a brightest or darkest pixel in the image.

  13. High-quality remote interactive imaging in the operating theatre

    Science.gov (United States)

    Grimstead, Ian J.; Avis, Nick J.; Evans, Peter L.; Bocca, Alan

    2009-02-01

    We present a high-quality display system that enables the remote access within an operating theatre of high-end medical imaging and surgical planning software. Currently, surgeons often use printouts from such software for reference during surgery; our system enables surgeons to access and review patient data in a sterile environment, viewing real-time renderings of MRI & CT data as required. Once calibrated, our system displays shades of grey in Operating Room lighting conditions (removing any gamma correction artefacts). Our system does not require any expensive display hardware, is unobtrusive to the remote workstation and works with any application without requiring additional software licenses. To extend the native 256 levels of grey supported by a standard LCD monitor, we have used the concept of "PseudoGrey" where slightly off-white shades of grey are used to extend the intensity range from 256 to 1,785 shades of grey. Remote access is facilitated by a customized version of UltraVNC, which corrects remote shades of grey for display in the Operating Room. The system is successfully deployed at Morriston Hospital, Swansea, UK, and is in daily use during Maxillofacial surgery. More formal user trials and quantitative assessments are being planned for the future.

  14. Imaging and computational considerations for image computed permeability: Operating envelope of Digital Rock Physics

    Science.gov (United States)

    Saxena, Nishank; Hows, Amie; Hofmann, Ronny; Alpak, Faruk O.; Freeman, Justin; Hunter, Sander; Appel, Matthias

    2018-06-01

    This study defines the optimal operating envelope of the Digital Rock technology from the perspective of imaging and numerical simulations of transport properties. Imaging larger volumes of rocks for Digital Rock Physics (DRP) analysis improves the chances of achieving a Representative Elementary Volume (REV) at which flow-based simulations (1) do not vary with change in rock volume, and (2) is insensitive to the choice of boundary conditions. However, this often comes at the expense of image resolution. This trade-off exists due to the finiteness of current state-of-the-art imaging detectors. Imaging and analyzing digital rocks that sample the REV and still sufficiently resolve pore throats is critical to ensure simulation quality and robustness of rock property trends for further analysis. We find that at least 10 voxels are needed to sufficiently resolve pore throats for single phase fluid flow simulations. If this condition is not met, additional analyses and corrections may allow for meaningful comparisons between simulation results and laboratory measurements of permeability, but some cases may fall outside the current technical feasibility of DRP. On the other hand, we find that the ratio of field of view and effective grain size provides a reliable measure of the REV for siliciclastic rocks. If this ratio is greater than 5, the coefficient of variation for single-phase permeability simulations drops below 15%. These imaging considerations are crucial when comparing digitally computed rock flow properties with those measured in the laboratory. We find that the current imaging methods are sufficient to achieve both REV (with respect to numerical boundary conditions) and required image resolution to perform digital core analysis for coarse to fine-grained sandstones.

  15. Microdose fluorescence imaging of ABY-029 on an operating microscope adapted by custom illumination and imaging modules

    OpenAIRE

    Elliott, Jonathan T.; Dsouza, Alisha V.; Marra, Kayla; Pogue, Brian W.; Roberts, David W.; Paulsen, Keith D.

    2016-01-01

    Fluorescence guided surgery has the potential to positively impact surgical oncology; current operating microscopes and stand-alone imaging systems are too insensitive or too cumbersome to maximally take advantage of new tumor-specific agents developed through the microdose pathway. To this end, a custom-built illumination and imaging module enabling picomolar-sensitive near-infrared fluorescence imaging on a commercial operating microscope is described. The limits of detection and system spe...

  16. LANDSAT-8 OPERATIONAL LAND IMAGER CHANGE DETECTION ANALYSIS

    Directory of Open Access Journals (Sweden)

    W. Pervez

    2017-05-01

    Full Text Available This paper investigated the potential utility of Landsat-8 Operational Land Imager (OLI for change detection analysis and mapping application because of its superior technical design to previous Landsat series. The OLI SVM classified data was successfully classified with regard to all six test classes (i.e., bare land, built-up land, mixed trees, bushes, dam water and channel water. OLI support vector machine (SVM classified data for the four seasons (i.e., spring, autumn, winter, and summer was used to change detection results of six cases: (1 winter to spring which resulted reduction in dam water mapping and increases of bushes; (2 winter to summer which resulted reduction in dam water mapping and increase of vegetation; (3 winter to autumn which resulted increase in dam water mapping; (4 spring to summer which resulted reduction of vegetation and shallow water; (5 spring to autumn which resulted decrease of vegetation; and (6 summer to autumn which resulted increase of bushes and vegetation . OLI SVM classified data resulted higher overall accuracy and kappa coefficient and thus found suitable for change detection analysis.

  17. An operative quantitative analysis of multispectral images of the eyeground

    Science.gov (United States)

    Lisenko, S. A.; Kugeiko, M. M.; Firago, V. A.; Kubarko, A. I.

    2014-09-01

    In the approximation of a four-layer model of the eyeground, we have studied the information content of photographs of the eyeground obtained in different spectral intervals from the visible range of the spectrum. We have shown that, under conditions of a priori uncertainty of all parameters of the eyeground that affect spectral fluxes of light multiply scattered by the eyeground, the two-dimensional distributions of the following parameters can be determined: (i) the contents of hemoglobin and macular pigment in the retina; (ii) the contents of melanin in the pigment epithelium and choroid; (iii) the degree of blood oxygenation; and (iv) the structural parameter of the retina, which characterizes the volume concentration of its effective scatterers. Based on results of a numerical simulation of the light-transfer process in the medium under study, we have determined regression relationships between parameters of the eyeground and spectral characteristics of its image and have proposed a method for the operative retrieval of parameter maps of the eyeground, which uses the determined regressions.

  18. Operational Analysis of Time-Optimal Maneuvering for Imaging Spacecraft

    Science.gov (United States)

    2013-03-01

    Figure 1.  In-Track Stereo Satellite Image Collection. From [7] ............................ 3  Figure 2.  NASA MODIS Terra Satellite Image of Oil...satellites for remote sensing ranges from military applications to tracking global weather patterns, tectonic activity, surface vegetation , ocean...imagery [22]. Figure 2 shows an example of a satellite image captured by the Moderate Resolution Imaging Spectroradiometer (MODIS) on NASA’s Terra

  19. Intraoperative near-infrared fluorescent imaging during robotic operations.

    Science.gov (United States)

    Macedo, Antonio Luiz de Vasconcellos; Schraibman, Vladimir

    2016-01-01

    The intraoperative identification of certain anatomical structures because they are small or visually occult may be challenging. The development of minimally invasive surgery brought additional difficulties to identify these structures due to the lack of complete tactile sensitivity. A number of different forms of intraoperative mapping have been tried. Recently, the near-infrared fluorescence imaging technology with indocyanine green has been added to robotic platforms. In addition, this technology has been tested in several types of operations, and has advantages such as safety, low cost and good results. Disadvantages are linked to contrast distribution in certain clinical scenarios. The intraoperative near-infrared fluorescent imaging is new and promising addition to robotic surgery. Several reports show the utility of this technology in several different procedures. The ideal dose, time and site for dye injection are not well defined. No high quality evidence-based comparative studies and long-term follow-up outcomes have been published so far. Initial results, however, are good and safe. RESUMO A identificação intraoperatória de certas estruturas anatômicas, por seu tamanho ou por elas serem ocultas à visão, pode ser desafiadora. O desenvolvimento da cirurgia minimamente invasiva trouxe dificuldades adicionais, pela falta da sensibilidade tátil completa. Diversas formas de detecção intraoperatória destas estruturas têm sido tentadas. Recentemente, a tecnologia de fluorescência infravermelha com verde de indocianina foi associada às plataformas robóticas. Além disso, essa tecnologia tem sido testada em uma variedade de cirurgias, e suas vantagens parecem estar ligadas a baixo custo, segurança e bons resultados. As desvantagens estão associadas à má distribuição do contraste em determinados cenários. A imagem intraoperatória por fluorescência infravermelha é uma nova e promissora adição à cirurgia robótica. Diversas séries mostram

  20. Pre-, intra- and post-operative imaging of cochlear implants

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Naguib, N.N.N.; Burck, I. [University Hospital Frankfurt (Germany). Inst. of Diagnostic and Interventional Radiology; Tawfik, A. [Mansoura Univ. (Egypt). Dept. of Diagnostic and Interventional Radiology; Emam, A. [University Hospital Alexandria (Egypt). Dept. of Diagnostic and Interventional Radiology; Nour-Eldin, A. [University Hospital Cairo (Egypt). Dept. of Radiology; Stoever, T. [University Hospital of Frankfurt (Germany). Dept. of Otolaryngology

    2015-11-15

    The purpose of this review is to present essential imaging aspects in patients who are candidates for a possible cochlear implant as well as in postsurgical follow-up. Imaging plays a major role in providing information on preinterventional topography, variations and possible infections. Preoperative imaging using DVT, CT, MRI or CT and MRI together is essential for candidate selection, planning of surgical approach and exclusion of contraindications like the complete absence of the cochlea or cochlear nerve, or infection. Relative contraindications are variations of the cochlea and vestibulum. Intraoperative imaging can be performed by fluoroscopy, mobile radiography or DVT. Postoperative imaging is regularly performed by conventional X-ray, DVT, or CT. In summary, radiological imaging has its essential role in the pre- and post-interventional period for patients who are candidates for cochlear implants.

  1. Complications of rotator cuff surgery—the role of post-operative imaging in patient care

    Science.gov (United States)

    Thakkar, R S; Thakkar, S C; Srikumaran, U; Fayad, L M

    2014-01-01

    When pain or disability occurs after rotator cuff surgery, post-operative imaging is frequently performed. Post-operative complications and expected post-operative imaging findings in the shoulder are presented, with a focus on MRI, MR arthrography (MRA) and CT arthrography. MR and CT techniques are available to reduce image degradation secondary to surgical distortions of native anatomy and implant-related artefacts and to define complications after rotator cuff surgery. A useful approach to image the shoulder after surgery is the standard radiography, followed by MRI/MRA for patients with low “metal presence” and CT for patients who have a higher metal presence. However, for the assessment of patients who have undergone surgery for rotator cuff injuries, imaging findings should always be correlated with the clinical presentation because post-operative imaging abnormalities do not necessarily correlate with symptoms. PMID:24734935

  2. Microdose fluorescence imaging of ABY-029 on an operating microscope adapted by custom illumination and imaging modules.

    Science.gov (United States)

    Elliott, Jonathan T; Dsouza, Alisha V; Marra, Kayla; Pogue, Brian W; Roberts, David W; Paulsen, Keith D

    2016-09-01

    Fluorescence guided surgery has the potential to positively impact surgical oncology; current operating microscopes and stand-alone imaging systems are too insensitive or too cumbersome to maximally take advantage of new tumor-specific agents developed through the microdose pathway. To this end, a custom-built illumination and imaging module enabling picomolar-sensitive near-infrared fluorescence imaging on a commercial operating microscope is described. The limits of detection and system specifications are characterized, and in vivo efficacy of the system in detecting ABY-029 is evaluated in a rat orthotopic glioma model following microdose injections, showing the suitability of the device for microdose phase 0 clinical trials.

  3. Error analysis of filtering operations in pixel-duplicated images of diabetic retinopathy

    Science.gov (United States)

    Mehrubeoglu, Mehrube; McLauchlan, Lifford

    2010-08-01

    In this paper, diabetic retinopathy is chosen for a sample target image to demonstrate the effectiveness of image enlargement through pixel duplication in identifying regions of interest. Pixel duplication is presented as a simpler alternative to data interpolation techniques for detecting small structures in the images. A comparative analysis is performed on different image processing schemes applied to both original and pixel-duplicated images. Structures of interest are detected and and classification parameters optimized for minimum false positive detection in the original and enlarged retinal pictures. The error analysis demonstrates the advantages as well as shortcomings of pixel duplication in image enhancement when spatial averaging operations (smoothing filters) are also applied.

  4. NOAA Geostationary Operational Environmental Satellite (GOES) Imager Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NOAA Geostationary Operational Environmental Satellite (GOES) series provides continuous measurements of the atmosphere and surface over the Western Hemisphere....

  5. Operational Data Augmentation in Classifying Single Aerial Images of Animals

    NARCIS (Netherlands)

    Okafor, Emmanuel; Smit, Rik; Schomaker, Lambertus; Wiering, Marco

    2017-01-01

    In deep learning, data augmentation is important to increase the amount of training images to obtain higher classification accuracies. Most data-augmentation methods adopt the use of the following techniques: cropping, mirroring, color casting, scaling and rotation for creating additional training

  6. Augmenting camera images for operators of Unmanned Aerial Vehicles

    NARCIS (Netherlands)

    Veltman, J.A.; Oving, A.B.

    2003-01-01

    The manual control of the camera of an unmanned aerial vehicle (UAV) can be difficult due to several factors such as 1) time delays between steering input and changes of the monitor content, 2) low update rates of the camera images and 3) lack of situation awareness due to the remote position of the

  7. Use of focus measure operators for characterization of flood illumination adaptive optics ophthalmoscopy image quality.

    Science.gov (United States)

    Alonso-Caneiro, David; Sampson, Danuta M; Chew, Avenell L; Collins, Michael J; Chen, Fred K

    2018-02-01

    Adaptive optics flood illumination ophthalmoscopy (AO-FIO) allows imaging of the cone photoreceptor in the living human retina. However, clinical interpretation of the AO-FIO image remains challenging due to suboptimal quality arising from residual uncorrected wavefront aberrations and rapid eye motion. An objective method of assessing image quality is necessary to determine whether an AO-FIO image is suitable for grading and diagnostic purpose. In this work, we explore the use of focus measure operators as a surrogate measure of AO-FIO image quality. A set of operators are tested on data sets acquired at different focal depths and different retinal locations from healthy volunteers. Our results demonstrate differences in focus measure operator performance in quantifying AO-FIO image quality. Further, we discuss the potential application of the selected focus operators in (i) selection of the best quality AO-FIO image from a series of images collected at the same retinal location and (ii) assessment of longitudinal changes in the diseased retina. Focus function could be incorporated into real-time AO-FIO image processing and provide an initial automated quality assessment during image acquisition or reading center grading.

  8. Operating within the legal and ethical framework to gain co-operation when imaging paediatric patients

    International Nuclear Information System (INIS)

    Harvey-Lloyd, Jane M.

    2013-01-01

    This paper discusses the challenges faced by radiographers when imaging children. Using Maslow's Hierarchy of Needs as a framework it presents a logical exploration of the complex issues associated with imaging children and considers the legal and ethical framework alongside the nature of motivation and importance of gaining cooperation of the child and their carer(s). It is evident that a good knowledge of child development, child psychology and distraction techniques would enhance the family experience when attending for imaging examinations. Radiographers must continually familiarise themselves with current legislation affecting their practice and ensure that they continue to provide an optimum service for children and their carer(s). It may be advisable for post-registration courses to be offered to existing practitioners and for the Society and College of Radiographers to consider appointing a professional officer with expertise in paediatric imaging to offer legal advice and to support safe practice

  9. Landsat 8 Operational Land Imager (OLI)_Thermal Infared Sensor (TIRS) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract:The Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) are instruments onboard the Landsat 8 satellite, which was launched in February of...

  10. Sparse PDF maps for non-linear multi-resolution image operations

    KAUST Repository

    Hadwiger, Markus; Sicat, Ronell Barrera; Beyer, Johanna; Krü ger, Jens J.; Mö ller, Torsten

    2012-01-01

    feasible for gigapixel images, while enabling direct evaluation of a variety of non-linear operators from the same representation. We illustrate this versatility for antialiased color mapping, O(n) local Laplacian filters, smoothed local histogram filters

  11. Natural Image Enhancement Using a Biogeography Based Optimization Enhanced with Blended Migration Operator

    Directory of Open Access Journals (Sweden)

    J. Jasper

    2014-01-01

    Full Text Available This paper addresses a novel and efficient algorithm for solving optimization problem in image processing applications. Image enhancement (IE is one of the complex optimization problems in image processing. The main goal of this paper is to enhance color images such that the eminence of the image is more suitable than the original image from the perceptual viewpoint of human. Traditional methods require prior knowledge of the image to be enhanced, whereas the aim of the proposed biogeography based optimization (BBO enhanced with blended migration operator (BMO algorithm is to maximize the objective function in order to enhance the image contrast by maximizing the parameters like edge intensity, edge information, and entropy. Experimental results are compared with the current state-of-the-art approaches and indicate the superiority of the proposed technique in terms of subjective and objective evaluation.

  12. [Preoperative imaging/operation planning for liver surgery].

    Science.gov (United States)

    Schoening, W N; Denecke, T; Neumann, U P

    2015-12-01

    The currently established standard for planning liver surgery is multistage contrast media-enhanced multidetector computed tomography (CM-CT), which as a rule enables an appropriate resection planning, e.g. a precise identification and localization of primary and secondary liver tumors as well as the anatomical relation to extrahepatic and/or intrahepatic vascular and biliary structures. Furthermore, CM-CT enables the measurement of tumor volume, total liver volume and residual liver volume after resection. Under the condition of normal liver function a residual liver volume of 25 % is nowadays considered sufficient and safe. Recent studies in patients with liver metastases of colorectal cancer showed a clear staging advantage of contrast media-enhanced magnetic resonance imaging (CM-MRI) versus CM-CT. In addition, most recent data showed that the use of liver-specific MRI contrast media further increases the sensitivity and specificity of detection of liver metastases. This imaging technology seems to lead closer to the ideal "one stop shopping" diagnostic tool in preoperative planning of liver resection.

  13. Tank 241-C-106 in-tank imaging system operational test report

    International Nuclear Information System (INIS)

    Pedersen, L.T.

    1998-01-01

    This document presents the results of operational testing of the 241-C-106 In-Tank Video Camera Imaging System. This imaging system was installed as a component of Project W-320 to monitor sluicing and waste retrieval activities in Tank 241-C-106

  14. The Cancer Imaging Archive (TCIA): maintaining and operating a public information repository.

    Science.gov (United States)

    Clark, Kenneth; Vendt, Bruce; Smith, Kirk; Freymann, John; Kirby, Justin; Koppel, Paul; Moore, Stephen; Phillips, Stanley; Maffitt, David; Pringle, Michael; Tarbox, Lawrence; Prior, Fred

    2013-12-01

    The National Institutes of Health have placed significant emphasis on sharing of research data to support secondary research. Investigators have been encouraged to publish their clinical and imaging data as part of fulfilling their grant obligations. Realizing it was not sufficient to merely ask investigators to publish their collection of imaging and clinical data, the National Cancer Institute (NCI) created the open source National Biomedical Image Archive software package as a mechanism for centralized hosting of cancer related imaging. NCI has contracted with Washington University in Saint Louis to create The Cancer Imaging Archive (TCIA)-an open-source, open-access information resource to support research, development, and educational initiatives utilizing advanced medical imaging of cancer. In its first year of operation, TCIA accumulated 23 collections (3.3 million images). Operating and maintaining a high-availability image archive is a complex challenge involving varied archive-specific resources and driven by the needs of both image submitters and image consumers. Quality archives of any type (traditional library, PubMed, refereed journals) require management and customer service. This paper describes the management tasks and user support model for TCIA.

  15. Sparse PDF maps for non-linear multi-resolution image operations

    KAUST Repository

    Hadwiger, Markus

    2012-11-01

    We introduce a new type of multi-resolution image pyramid for high-resolution images called sparse pdf maps (sPDF-maps). Each pyramid level consists of a sparse encoding of continuous probability density functions (pdfs) of pixel neighborhoods in the original image. The encoded pdfs enable the accurate computation of non-linear image operations directly in any pyramid level with proper pre-filtering for anti-aliasing, without accessing higher or lower resolutions. The sparsity of sPDF-maps makes them feasible for gigapixel images, while enabling direct evaluation of a variety of non-linear operators from the same representation. We illustrate this versatility for antialiased color mapping, O(n) local Laplacian filters, smoothed local histogram filters (e.g., median or mode filters), and bilateral filters. © 2012 ACM.

  16. Multiple image encryption scheme based on pixel exchange operation and vector decomposition

    Science.gov (United States)

    Xiong, Y.; Quan, C.; Tay, C. J.

    2018-02-01

    We propose a new multiple image encryption scheme based on a pixel exchange operation and a basic vector decomposition in Fourier domain. In this algorithm, original images are imported via a pixel exchange operator, from which scrambled images and pixel position matrices are obtained. Scrambled images encrypted into phase information are imported using the proposed algorithm and phase keys are obtained from the difference between scrambled images and synthesized vectors in a charge-coupled device (CCD) plane. The final synthesized vector is used as an input in a random phase encoding (DRPE) scheme. In the proposed encryption scheme, pixel position matrices and phase keys serve as additional private keys to enhance the security of the cryptosystem which is based on a 4-f system. Numerical simulations are presented to demonstrate the feasibility and robustness of the proposed encryption scheme.

  17. Imaging through obscurations for sluicing operations in the waste storage tanks

    International Nuclear Information System (INIS)

    Peters, T.J.; McMakin, D.L.; Sheen, D.M.; Chieda, M.A.

    1994-08-01

    Waste remediators have identified that surveillance of waste remediation operations and periodic inspections of stored waste are required under very demanding and difficult viewing environments. In many cases, obscurants such as dust or water vapor are generated as part of the remediation activity. Methods are required for viewing or imaging beyond the normal visual spectrum. Work space images guide the movement of remediation equipment, creating a need for rapidly updated, near real-time imaging capability. In addition, there is a need for three-dimensional topographical data to determine the contours of the wastes, to plan retrieval campaigns, and to provide a three-dimensional map of a robot's work space as basis for collision avoidance. Three basic imaging techniques were evaluated: optical, acoustic and radar. The optical imaging methods that were examined used cameras which operated in the visible region and near-infrared region and infrared cameras which operated in the 3--5 micron and 8--12 micron wavelength regions. Various passive and active lighting schemes were tested, as well as the use of filters to eliminate reflection in the visible region. Image enhancement software was used to extend the range where visual techniques could be used. In addition, the operation of a laser range finder, which operated at 0.835 microns, was tested when fog/water droplets were suspended in the air. The acoustic technique involved using commercial acoustic sensors, operating at approximately 50 kHz and 215 kHz, to determine the attenuation of the acoustic beam in a high-humidity environment. The radar imaging methods involved performing millimeter wave (94 GHz) attenuation measurement sin the various simulated sluicing environments and performing preliminary experimental imaging studies using a W-Band (75--110 GHz) linearly scanned transceiver in a laboratory environment. The results of the tests are discussed

  18. Hemorrhage in pituitary adenoma: correlation of MR imaging with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, N.; Takahashi, S.; Higano, S.; Mugikura, S.; Singh, L.N.; Furuta, S.; Tamura, H.; Ishibashi, T.; Maruoka, S.; Yamada, S. [Department of Radiology, Tohoku University School of Medicine, Sendai (Japan); Ikeda, H. [Department of Neurosurgery, Tohoku University School of Medicine, Sendai (Japan)

    1998-07-01

    The aim of this study was to correlate MR imaging and operative findings of hemorrhage in pituitary macroadenomas. We retrospectively reviewed MR images of 113 surgically proven pituitary adenomas. All patients were examined on a 1.5-T MR system. The intensity of intratumoral cystic cavities was correlated with operative findings. In 15 patients with pituitary apoplexy, we determined relationship between interval of MR examination after apoplectic event and MR signal intensity. In 8 patients with repeated preoperative MR examination, we evaluated sequential changes of intratumoral hemorrhage. There were 54 cavities at surgery: 52 were hemorrhagic and 2 were nonhemorrhagic. Twenty-nine of 52 hemorrhagic cysts demonstrated high/low signal (H/L) fluid-fluid levels on T2-weighted image (T2WI). In 19 of them, two components could be separately seen at operation: the supernatant high-intensity area represented xanthochromic fluid, and the dependent low-intensity area represented liquefied hematoma. The H/L fluid-fluid level was observed predominantly in hematomas on MR images obtained after longer intervals. In patients with repeated MR examination, follow-up MR imaging revealed additional hemorrhage or new formation of fluid-fluid levels. It was surprising that 12 of 14 cysts preoperatively judged as nonhemorrhagic in fact contained hemorrhagic components. The preoperative MR images are well correlated to the operative findings in hemorrhagic pituitary macroadenomas. It proved that 52 of 54 cystic cavities had hemorrhagic component. (orig.) With 8 figs., 3 tabs., 17 refs.

  19. Hemorrhage in pituitary adenoma: correlation of MR imaging with operative findings

    International Nuclear Information System (INIS)

    Kurihara, N.; Takahashi, S.; Higano, S.; Mugikura, S.; Singh, L.N.; Furuta, S.; Tamura, H.; Ishibashi, T.; Maruoka, S.; Yamada, S.; Ikeda, H.

    1998-01-01

    The aim of this study was to correlate MR imaging and operative findings of hemorrhage in pituitary macroadenomas. We retrospectively reviewed MR images of 113 surgically proven pituitary adenomas. All patients were examined on a 1.5-T MR system. The intensity of intratumoral cystic cavities was correlated with operative findings. In 15 patients with pituitary apoplexy, we determined relationship between interval of MR examination after apoplectic event and MR signal intensity. In 8 patients with repeated preoperative MR examination, we evaluated sequential changes of intratumoral hemorrhage. There were 54 cavities at surgery: 52 were hemorrhagic and 2 were nonhemorrhagic. Twenty-nine of 52 hemorrhagic cysts demonstrated high/low signal (H/L) fluid-fluid levels on T2-weighted image (T2WI). In 19 of them, two components could be separately seen at operation: the supernatant high-intensity area represented xanthochromic fluid, and the dependent low-intensity area represented liquefied hematoma. The H/L fluid-fluid level was observed predominantly in hematomas on MR images obtained after longer intervals. In patients with repeated MR examination, follow-up MR imaging revealed additional hemorrhage or new formation of fluid-fluid levels. It was surprising that 12 of 14 cysts preoperatively judged as nonhemorrhagic in fact contained hemorrhagic components. The preoperative MR images are well correlated to the operative findings in hemorrhagic pituitary macroadenomas. It proved that 52 of 54 cystic cavities had hemorrhagic component. (orig.)

  20. A comparative study of MR imaging scores and MR perfusion imaging in pre-operative grading of intracranial gliomas

    International Nuclear Information System (INIS)

    Wu Honglin; Chen Junkun; Zhang Zongjun; Lu Guangming; Chen Ziqian; Wang Wei; Ji Xueman; Tang Xiaojun; Li Lin

    2005-01-01

    Objective: To compare the accuracy of MR imaging scores with MR perfusion imaging in pre-operative grading of intracranial gliomas. Methods: Thirty patients with intracranial gliomas (8 low-grade and 22 high-grade, according to WHO criteria) were examined with MR perfusion imaging pre-operatively. The lesions were evaluated by using an MR imaging score based on nine criteria. rCBV of the lesions were calculated by comparing the CBV of the lesion and that of contralateral normal white matter. The scores and ratios in high-grade and low-grade tumours were compared. Results: The MR imaging score of low grade (grades I and II) gliomas (0.67±0.29) were significantly lower than that of grades III (1.32 ± 0.47) (t=-3.48, P=0.003) and IV (1.56 ± 0.20) (t=-7.36, P=0.000) gliomas. There was no statistical difference when MR imaging scores of grades III and IV gliomas (t=-1.39, P=0.182) were compared. The maximum rCBV ratio of low grade (grades I and II) gliomas (2.38 ± 0.66 ) were significantly lower than that of grades III (5.81 ± 3.20) (t=-3.57, P=0.003) and IV (6.99 ± 2.47) (t=-5.09, P=0.001). There was no statistical difference when rCBV ratios of grades III and IV (t =-0.93, P=0.365) gliomas were compared. The accuracy of MR imaging scores in the noninvasive grading of untreated gliomas was all most the same as that of MR perfusion imaging (90.00% vs 89.29%). Conclusion: The MR imaging scores and MR perfusion imaging are two very useful tools in the evaluation of the histopathologic grade of cerebral gliomas. The overall accuracy in the noninvasive grading of gliomas may be imp roved if MR imaging scores and MR perfusion imaging are combined. (authors)

  1. Using 3 Tesla magnetic resonance imaging in the pre-operative evaluation of tongue carcinoma.

    Science.gov (United States)

    Moreno, K F; Cornelius, R S; Lucas, F V; Meinzen-Derr, J; Patil, Y J

    2017-09-01

    This study aimed to evaluate the role of 3 Tesla magnetic resonance imaging in predicting tongue tumour thickness via direct and reconstructed measures, and their correlations with corresponding histological measures, nodal metastasis and extracapsular spread. A prospective study was conducted of 25 patients with histologically proven squamous cell carcinoma of the tongue and pre-operative 3 Tesla magnetic resonance imaging from 2009 to 2012. Correlations between 3 Tesla magnetic resonance imaging and histological measures of tongue tumour thickness were assessed using the Pearson correlation coefficient: r values were 0.84 (p Tesla magnetic resonance imaging had 83 per cent sensitivity, 82 per cent specificity, 82 per cent accuracy and a 90 per cent negative predictive value for detecting cervical lymph node metastasis. In this cohort, 3 Tesla magnetic resonance imaging measures of tumour thickness correlated highly with the corresponding histological measures. Further, 3 Tesla magnetic resonance imaging was an effective method of detecting malignant adenopathy with extracapsular spread.

  2. Intra-operative nuclear imaging based on positron-emitting radiotracers

    International Nuclear Information System (INIS)

    Shakir, Dzhoshkun Ismail

    2014-01-01

    Positron-emitting radiotracers are an important part of nuclear medical imaging processes. Besides the very famous glucose analog [ 18 F]FDG, many not so well known ones exist, among them the particularly interesting amino acid-based tracers like [ 18 F]FET. Although peri-operative imaging with positron-emitting radiotracers has become state-of- the-art in cases of many types of cancer, their capability is not fully exploited in the operating room yet. In this thesis we explore two intra-operative nuclear imaging modalities exploiting different aspects of positron radiation towards quality assurance in challenging surgical treatment scenarios. The first modality freehand PET provides a tomographic image of a volume of interest and aims at minimizing invasiveness by assisting the surgeon in pinpointing target structures marked with a radiotracer. The second imaging modality epiphanography generates an image of the radiotracer distribution on a surface of interest and aims at providing a means for improving the control of tumor resection margins. The word epiphanography is a compound of the Greek words επιφανεια (epiphaneia) for surface and ζωγραφια (ographia) for image, and hence means the image of the surface similar to the compound τομοζ (tomos) for slice/volume and ζωγραφια (ographia) for image, meaning the image of the volume, i.e. tomography. To our knowledge this is the first use of the word epiphanography in the context of nuclear medical imaging. In this thesis we present our approach to modeling, developing and calibrating these two novel imaging modalities. In addition, we present our work towards their clinical integration. In the case of freehand PET, we have already acquired the first intra-operative datasets of a patient. We present this first experience in the operating room together with our phantom studies. In the case of epiphanography, we present our phantom studies with neurosurgeons towards the integration of this

  3. Large-Scale Multi-Resolution Representations for Accurate Interactive Image and Volume Operations

    KAUST Repository

    Sicat, Ronell B.

    2015-11-25

    The resolutions of acquired image and volume data are ever increasing. However, the resolutions of commodity display devices remain limited. This leads to an increasing gap between data and display resolutions. To bridge this gap, the standard approach is to employ output-sensitive operations on multi-resolution data representations. Output-sensitive operations facilitate interactive applications since their required computations are proportional only to the size of the data that is visible, i.e., the output, and not the full size of the input. Multi-resolution representations, such as image mipmaps, and volume octrees, are crucial in providing these operations direct access to any subset of the data at any resolution corresponding to the output. Despite its widespread use, this standard approach has some shortcomings in three important application areas, namely non-linear image operations, multi-resolution volume rendering, and large-scale image exploration. This dissertation presents new multi-resolution representations for large-scale images and volumes that address these shortcomings. Standard multi-resolution representations require low-pass pre-filtering for anti- aliasing. However, linear pre-filters do not commute with non-linear operations. This becomes problematic when applying non-linear operations directly to any coarse resolution levels in standard representations. Particularly, this leads to inaccurate output when applying non-linear image operations, e.g., color mapping and detail-aware filters, to multi-resolution images. Similarly, in multi-resolution volume rendering, this leads to inconsistency artifacts which manifest as erroneous differences in rendering outputs across resolution levels. To address these issues, we introduce the sparse pdf maps and sparse pdf volumes representations for large-scale images and volumes, respectively. These representations sparsely encode continuous probability density functions (pdfs) of multi-resolution pixel

  4. A novel color image encryption scheme using fractional-order hyperchaotic system and DNA sequence operations

    International Nuclear Information System (INIS)

    Zhang Li-Min; Sun Ke-Hui; Liu Wen-Hao; He Shao-Bo

    2017-01-01

    In this paper, Adomian decomposition method (ADM) with high accuracy and fast convergence is introduced to solve the fractional-order piecewise-linear (PWL) hyperchaotic system. Based on the obtained hyperchaotic sequences, a novel color image encryption algorithm is proposed by employing a hybrid model of bidirectional circular permutation and DNA masking. In this scheme, the pixel positions of image are scrambled by circular permutation, and the pixel values are substituted by DNA sequence operations. In the DNA sequence operations, addition and substraction operations are performed according to traditional addition and subtraction in the binary, and two rounds of addition rules are used to encrypt the pixel values. The simulation results and security analysis show that the hyperchaotic map is suitable for image encryption, and the proposed encryption algorithm has good encryption effect and strong key sensitivity. It can resist brute-force attack, statistical attack, differential attack, known-plaintext, and chosen-plaintext attacks. (paper)

  5. Medial collateral ligament tear entrapped within a proximal tibial physeal separation: imaging findings and operative reduction

    Energy Technology Data Exchange (ETDEWEB)

    McAnally, James L.; Eberhardt, Steven C.; Mlady, Gary W. [University of New Mexico, Department of Radiology, Albuquerque, NM (United States); Fitzpatrick, Jennifer; Bosch, Patrick [University of New Mexico, Department of Orthopaedics and Rehabilitation, Albuquerque, NM (United States)

    2008-10-15

    Entrapped soft tissues such as periosteum and tendons have been described within joints and physeal fractures in the literature and frequently result in irreducible fractures and posttraumatic growth disturbances. We believe this case represents a novel presentation of acute, preoperative, magnetic resonance (MR) imaging diagnosis of a torn medial collateral ligament entrapped within a proximal tibial physeal separation. This case is presented with MR imaging and operative correlation of the findings. (orig.)

  6. Medial collateral ligament tear entrapped within a proximal tibial physeal separation: imaging findings and operative reduction

    International Nuclear Information System (INIS)

    McAnally, James L.; Eberhardt, Steven C.; Mlady, Gary W.; Fitzpatrick, Jennifer; Bosch, Patrick

    2008-01-01

    Entrapped soft tissues such as periosteum and tendons have been described within joints and physeal fractures in the literature and frequently result in irreducible fractures and posttraumatic growth disturbances. We believe this case represents a novel presentation of acute, preoperative, magnetic resonance (MR) imaging diagnosis of a torn medial collateral ligament entrapped within a proximal tibial physeal separation. This case is presented with MR imaging and operative correlation of the findings. (orig.)

  7. [The hybrid operating room. Home of high-end intraoperative imaging].

    Science.gov (United States)

    Gebhard, F; Riepl, C; Richter, P; Liebold, A; Gorki, H; Wirtz, R; König, R; Wilde, F; Schramm, A; Kraus, M

    2012-02-01

    A hybrid operating room must serve the medical needs of different highly specialized disciplines. It integrates interventional techniques for cardiovascular procedures and allows operations in the field of orthopaedic surgery, neurosurgery and maxillofacial surgery. The integration of all steps such as planning, documentation and the procedure itself saves time and precious resources. The best available imaging devices and user interfaces reduce the need for extensive personnel in the OR and facilitate new minimally invasive procedures. The immediate possibility of postoperative control images in CT-like quality enables the surgeon to react to problems during the same procedure without the need for later revision.

  8. The application of heliospheric imaging to space weather operations: Lessons learned from published studies

    Science.gov (United States)

    Harrison, Richard A.; Davies, Jackie A.; Biesecker, Doug; Gibbs, Mark

    2017-08-01

    The field of heliospheric imaging has matured significantly over the last 10 years—corresponding, in particular, to the launch of NASA's STEREO mission and the successful operation of the heliospheric imager (HI) instruments thereon. In parallel, this decade has borne witness to a marked increase in concern over the potentially damaging effects of space weather on space and ground-based technological assets, and the corresponding potential threat to human health, such that it is now under serious consideration at governmental level in many countries worldwide. Hence, in a political climate that recognizes the pressing need for enhanced operational space weather monitoring capabilities most appropriately stationed, it is widely accepted, at the Lagrangian L1 and L5 points, it is timely to assess the value of heliospheric imaging observations in the context of space weather operations. To this end, we review a cross section of the scientific analyses that have exploited heliospheric imagery—particularly from STEREO/HI—and discuss their relevance to operational predictions of, in particular, coronal mass ejection (CME) arrival at Earth and elsewhere. We believe that the potential benefit of heliospheric images to the provision of accurate CME arrival predictions on an operational basis, although as yet not fully realized, is significant and we assert that heliospheric imagery is central to any credible space weather mission, particularly one located at a vantage point off the Sun-Earth line.

  9. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    International Nuclear Information System (INIS)

    Lin, Pei-Jan Paul

    2009-01-01

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  10. Intraoperative intrinsic optical imaging of human somatosensory cortex during neurosurgical operations.

    Science.gov (United States)

    Sato, Katsushige; Nariai, Tadashi; Momose-Sato, Yoko; Kamino, Kohtaro

    2017-07-01

    Intrinsic optical imaging as developed by Grinvald et al. is a powerful technique for monitoring neural function in the in vivo central nervous system. The advent of this dye-free imaging has also enabled us to monitor human brain function during neurosurgical operations. We briefly describe our own experience in functional mapping of the human somatosensory cortex, carried out using intraoperative optical imaging. The maps obtained demonstrate new additional evidence of a hierarchy for sensory response patterns in the human primary somatosensory cortex.

  11. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Pei-Jan Paul [Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2009-05-15

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  12. Photoacoustic imaging in scattering media by combining a correlation matrix filter with a time reversal operator.

    Science.gov (United States)

    Rui, Wei; Tao, Chao; Liu, Xiaojun

    2017-09-18

    Acoustic scattering medium is a fundamental challenge for photoacoustic imaging. In this study, we reveal the different coherent properties of the scattering photoacoustic waves and the direct photoacoustic waves in a matrix form. Direct waves show a particular coherence on the antidiagonals of the matrix, whereas scattering waves do not. Based on this property, a correlation matrix filter combining with a time reversal operator is proposed to preserve the direct waves and recover the image behind a scattering layer. Both numerical simulations and photoacoustic imaging experiments demonstrate that the proposed approach effectively increases the image contrast and decreases the background speckles in a scattering medium. This study might improve the quality of photoacoustic imaging in an acoustic scattering environment and extend its applications.

  13. Real-time image processing and control interface for remote operation of a microscope

    Science.gov (United States)

    Leng, Hesong; Wilder, Joseph

    1999-08-01

    A real-time image processing and control interface for remote operation of a microscope is presented in this paper. The system has achieved real-time color image display for 640 X 480 pixel images. Multi-resolution image representation can be provided for efficient transmission through the network. Through the control interface the computer can communicate with the programmable microscope via the RS232 serial ports. By choosing one of three scanning patterns, a sequence of images can be saved as BMP or PGM files to record information on an entire microscope slide. The system will be used by medical and graduate students at the University of Medicine and Dentistry of New Jersey for distance learning. It can be used in many network-based telepathology applications.

  14. Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty.

    Science.gov (United States)

    Hambright, D; Hellman, M; Barrack, R

    2018-01-01

    The aims of this study were to examine the rate at which the positioning of the acetabular component, leg length discrepancy and femoral offset are outside an acceptable range in total hip arthroplasties (THAs) which either do or do not involve the use of intra-operative digital imaging. A retrospective case-control study was undertaken with 50 patients before and 50 patients after the integration of an intra-operative digital imaging system in THA. The demographics of the two groups were comparable for body mass index, age, laterality and the indication for surgery. The digital imaging group had more men than the group without. Surgical data and radiographic parameters, including the inclination and anteversion of the acetabular component, leg length discrepancy, and the difference in femoral offset compared with the contralateral hip were collected and compared, as well as the incidence of altering the position of a component based on the intra-operative image. Digital imaging took a mean of five minutes (2.3 to 14.6) to perform. Intra-operative changes with the use of digital imaging were made for 43 patients (86%), most commonly to adjust leg length and femoral offset. There was a decrease in the incidence of outliers when using intra-operative imaging compared with not using it in regard to leg length discrepancy (20% versus 52%, p = 0.001) and femoral offset inequality (18% versus 44%, p = 0.004). There was also a difference in the incidence of outliers in acetabular inclination (0% versus 7%, p = 0.023) and version (0% versus 4%, p = 0.114) compared with historical results of a high-volume surgeon at the same centre. The use of intra-operative digital imaging in THA improves the accuracy of the positioning of the components at THA without adding a substantial amount of time to the operation. Cite this article: Bone Joint J 2018;100B(1 Supple A):36-43. ©2018 The British Editorial Society of Bone & Joint Surgery.

  15. The w-effect in interferometric imaging: from a fast sparse measurement operator to superresolution

    Science.gov (United States)

    Dabbech, A.; Wolz, L.; Pratley, L.; McEwen, J. D.; Wiaux, Y.

    2017-11-01

    Modern radio telescopes, such as the Square Kilometre Array, will probe the radio sky over large fields of view, which results in large w-modulations of the sky image. This effect complicates the relationship between the measured visibilities and the image under scrutiny. In algorithmic terms, it gives rise to massive memory and computational time requirements. Yet, it can be a blessing in terms of reconstruction quality of the sky image. In recent years, several works have shown that large w-modulations promote the spread spectrum effect. Within the compressive sensing framework, this effect increases the incoherence between the sensing basis and the sparsity basis of the signal to be recovered, leading to better estimation of the sky image. In this article, we revisit the w-projection approach using convex optimization in realistic settings, where the measurement operator couples the w-terms in Fourier and the de-gridding kernels. We provide sparse, thus fast, models of the Fourier part of the measurement operator through adaptive sparsification procedures. Consequently, memory requirements and computational cost are significantly alleviated at the expense of introducing errors on the radio interferometric data model. We present a first investigation of the impact of the sparse variants of the measurement operator on the image reconstruction quality. We finally analyse the interesting superresolution potential associated with the spread spectrum effect of the w-modulation, and showcase it through simulations. Our c++ code is available online on GitHub.

  16. Alternative proposal of arithmetic and image operations in optical parallel computation

    Science.gov (United States)

    Ghosh, Partha; Das, Partha P.; Mukhopadhay, Sourangshu

    2001-10-01

    Here, we refer our new proposal of applying multi-valued logic (particularly tristate logic) to develop logic gates and systems for arithmetic operation. Space-variant approach is used here to implement the functioning. Also triple input image detection is done here.

  17. Awarable complexity: a study on CRT picture design based on plant images by NPP operators

    International Nuclear Information System (INIS)

    Kawano, Ryutaro; Ohtsuka, Tsutomu; Masugi, Tsuyoshi

    2000-01-01

    Original pictures installed in the 1st and 2nd generation type central control panels (CCP) and new 'Awarable and Complex' pictures were made on personal computers and evaluated. A total 18 of actual plant operators (M=32.3, SD=10.5 years old) participated in the evaluation. The operators rated the new CRT pictures highly. The response times using the new CRT pictures were shorter than those by the original pictures. Both results suggested that the CRT picture design guidelines based on the operators' plant images were effective for improving their performance. (author)

  18. Innovative operating modes and techniques for the spaceborne imaging radar-C instrument

    Science.gov (United States)

    Huneycutt, Bryan L.

    1990-01-01

    The operation of the spaceborne imaging radar-C (SIR-C) is discussed. The SIR-C instrument has been designed to obtain simultaneous multifrequency and simultaneous multipolarization radar images from a low earth orbit. It is a multiparameter imaging radar which will be flown during at least two different seasons. The instrument has been designed to operate in innovative modes such as the squint alignment mode, the extended aperture mode, the scansar mode, and the interferometry mode. The instrument has been designed to demonstrate innovative engineering techniques such as beam nulling for echo tracking, pulse-repetition frquency hopping for Doppler centroid tracking, generating the frequency step chirp for radar parameter flexibility, block floating point quantizing for data rate compression, and elevation beamwidth broadening for increasing the swath illumination.

  19. Vessel Segmentation in Retinal Images Using Multi-scale Line Operator and K-Means Clustering.

    Science.gov (United States)

    Saffarzadeh, Vahid Mohammadi; Osareh, Alireza; Shadgar, Bita

    2014-04-01

    Detecting blood vessels is a vital task in retinal image analysis. The task is more challenging with the presence of bright and dark lesions in retinal images. Here, a method is proposed to detect vessels in both normal and abnormal retinal fundus images based on their linear features. First, the negative impact of bright lesions is reduced by using K-means segmentation in a perceptive space. Then, a multi-scale line operator is utilized to detect vessels while ignoring some of the dark lesions, which have intensity structures different from the line-shaped vessels in the retina. The proposed algorithm is tested on two publicly available STARE and DRIVE databases. The performance of the method is measured by calculating the area under the receiver operating characteristic curve and the segmentation accuracy. The proposed method achieves 0.9483 and 0.9387 localization accuracy against STARE and DRIVE respectively.

  20. Pre-operative imaging of rectal cancer and its impact on surgical performance and treatment outcome.

    Science.gov (United States)

    Beets-Tan, R G H; Lettinga, T; Beets, G L

    2005-08-01

    To discuss the ability of pre-operative MRI to have a beneficial effect on surgical performance and treatment outcome in patients with rectal cancer. A description on how MRI can be used as a tool so select patients for differentiated neoadjuvant treatment, how it can be used as an anatomical road map for the resection of locally advanced cases, and how it can serve as a tool for quality assurance of both the surgical procedure and overall patient management. As an illustration the proportion of microscopically complete resections of the period 1993-1997, when there was no routine pre-operative imaging, is compared to that of the period 1998-2002, when pre-operative MR imaging was standardized. The proportion of R0 resections increased from 92.5 to 97% (p=0.08) and the proportion of resections with a lateral tumour free margin of >1mm increased from 84.4 to 92.1% (p=0.03). The incomplete resections in the first period were mainly due to inadequate surgical management of unsuspected advanced or bulky tumours, whereas in the second period insufficient consideration was given to extensive neoadjuvant treatment when the tumour was close to or invading the mesorectal fascia on MR. There are good indications that in our setting pre-operative MR imaging, along with other improvements in rectal cancer management, had a beneficial effect on patient outcome. Audit and discussion of the incomplete resections can lead to an improved operative and perioperative management.

  1. Trajectory-based morphological operators: a model for efficient image processing.

    Science.gov (United States)

    Jimeno-Morenilla, Antonio; Pujol, Francisco A; Molina-Carmona, Rafael; Sánchez-Romero, José L; Pujol, Mar

    2014-01-01

    Mathematical morphology has been an area of intensive research over the last few years. Although many remarkable advances have been achieved throughout these years, there is still a great interest in accelerating morphological operations in order for them to be implemented in real-time systems. In this work, we present a new model for computing mathematical morphology operations, the so-called morphological trajectory model (MTM), in which a morphological filter will be divided into a sequence of basic operations. Then, a trajectory-based morphological operation (such as dilation, and erosion) is defined as the set of points resulting from the ordered application of the instant basic operations. The MTM approach allows working with different structuring elements, such as disks, and from the experiments, it can be extracted that our method is independent of the structuring element size and can be easily applied to industrial systems and high-resolution images.

  2. Avalanche transistor pulser for fast-gated operation of micro-channel plate image-intensifiers

    International Nuclear Information System (INIS)

    Lundy, A.; Parker, J.R.; Lunsford, J.S.; Martin, A.D.

    1977-01-01

    Transistors operated in the avalanche mode are employed to generate a 1000 volt 10 to 30 nsec wide pulse with less than 4 nsec rise and fall times. This pulse is resistively attenuated to approximately equal to 270 volts and drives the image intensifier tube which is a load of approximately equal to 200 pf. To reduce stray inductance and capacitance, transistor chips were assembled on a thick-film hybrid substrate. Circuit parameters, operating conditions, and coupling to the microchannel plate image-intensifier (MCPI 2 ) tube are described. To provide dc operating voltages and control of transient voltages on the MCPI 2 tube a resistance-capacitance network has been developed which (a) places the MCPI 2 output phosphor at ground, (b) provides programmable gains in ''f-stop'' steps, and (c) minimizes voltage transients on the MCPI 2 tube

  3. High-intensity power-resolved radiation imaging of an operational nuclear reactor.

    Science.gov (United States)

    Beaumont, Jonathan S; Mellor, Matthew P; Villa, Mario; Joyce, Malcolm J

    2015-10-09

    Knowledge of the neutron distribution in a nuclear reactor is necessary to ensure the safe and efficient burnup of reactor fuel. Currently these measurements are performed by in-core systems in what are extremely hostile environments and in most reactor accident scenarios it is likely that these systems would be damaged. Here we present a compact and portable radiation imaging system with the ability to image high-intensity fast-neutron and gamma-ray fields simultaneously. This system has been deployed to image radiation fields emitted during the operation of a TRIGA test reactor allowing a spatial visualization of the internal reactor conditions to be obtained. The imaged flux in each case is found to scale linearly with reactor power indicating that this method may be used for power-resolved reactor monitoring and for the assay of ongoing nuclear criticalities in damaged nuclear reactors.

  4. Point-and-stare operation and high-speed image acquisition in real-time hyperspectral imaging

    Science.gov (United States)

    Driver, Richard D.; Bannon, David P.; Ciccone, Domenic; Hill, Sam L.

    2010-04-01

    The design and optical performance of a small-footprint, low-power, turnkey, Point-And-Stare hyperspectral analyzer, capable of fully automated field deployment in remote and harsh environments, is described. The unit is packaged for outdoor operation in an IP56 protected air-conditioned enclosure and includes a mechanically ruggedized fully reflective, aberration-corrected hyperspectral VNIR (400-1000 nm) spectrometer with a board-level detector optimized for point and stare operation, an on-board computer capable of full system data-acquisition and control, and a fully functioning internal hyperspectral calibration system for in-situ system spectral calibration and verification. Performance data on the unit under extremes of real-time survey operation and high spatial and high spectral resolution will be discussed. Hyperspectral acquisition including full parameter tracking is achieved by the addition of a fiber-optic based downwelling spectral channel for solar illumination tracking during hyperspectral acquisition and the use of other sensors for spatial and directional tracking to pinpoint view location. The system is mounted on a Pan-And-Tilt device, automatically controlled from the analyzer's on-board computer, making the HyperspecTM particularly adaptable for base security, border protection and remote deployments. A hyperspectral macro library has been developed to control hyperspectral image acquisition, system calibration and scene location control. The software allows the system to be operated in a fully automatic mode or under direct operator control through a GigE interface.

  5. Significance of operator variation and the angle of illumination in lineament analysis on synoptic images. [LANDSAT geological investigations

    Science.gov (United States)

    Siegal, B. S.; Short, N. M.

    1977-01-01

    The significance of operator variation and the angle of illumination in acquired imagery is analyzed for lineament analysis. Five operators analyzed a LANDSAT image and four photographs of a plastic relief map illuminated at a low angle from varying directions of the Prescott, Arizona region. Significant differences were found in both number and length of the lineaments recognized by the different investigators for the images. The actual coincidence of lineaments recognized by the investigators for the same image is exceptionally low. Even the directional data on lineament orientation is significantly different from operator to operator and from image to image. Cluster analysis of the orientation data displays a clustering by operators rather than by images. It is recommended that extreme caution be taken before attempting to compare different investigators' results in lineament analysis.

  6. Automatic detection of micro-aneurysms in retinal images based on curvelet transform and morphological operations

    Science.gov (United States)

    Mohammad Alipour, Shirin Hajeb; Rabbani, Hossein

    2013-09-01

    Diabetic retinopathy (DR) is one of the major complications of diabetes that changes the blood vessels of the retina and distorts patient vision that finally in high stages can lead to blindness. Micro-aneurysms (MAs) are one of the first pathologies associated with DR. The number and the location of MAs are very important in grading of DR. Early diagnosis of micro-aneurysms (MAs) can reduce the incidence of blindness. As MAs are tiny area of blood protruding from vessels in the retina and their size is about 25 to 100 microns, automatic detection of these tiny lesions is still challenging. MAs occurring in the macula can lead to visual loss. Also the position of a lesion such as MAs relative to the macula is a useful feature for analysis and classification of different stages of DR. Because MAs are more distinguishable in fundus fluorescin angiography (FFA) compared to color fundus images, we introduce a new method based on curvelet transform and morphological operations for MAs detection in FFA images. As vessels and MAs are the bright parts of FFA image, firstly extracted vessels by curvelet transform are removed from image. Then morphological operations are applied on resulted image for detecting MAs.

  7. Advances in non-Cartesian parallel magnetic resonance imaging using the GRAPPA operator

    Energy Technology Data Exchange (ETDEWEB)

    Seiberlich, Nicole

    2008-07-21

    This thesis has presented several new non-Cartesian parallel imaging methods which simplify both gridding and the reconstruction of images from undersampled data. A novel approach which uses the concepts of parallel imaging to grid data sampled along a non-Cartesian trajectory called GRAPPA Operator Gridding (GROG) is described. GROG shifts any acquired k-space data point to its nearest Cartesian location, thereby converting non-Cartesian to Cartesian data. The only requirements for GROG are a multi-channel acquisition and a calibration dataset for the determination of the GROG weights. Then an extension of GRAPPA Operator Gridding, namely Self-Calibrating GRAPPA Operator Gridding (SC-GROG) is discussed. SC-GROG is a method by which non-Cartesian data can be gridded using spatial information from a multi-channel coil array without the need for an additional calibration dataset, as required in standard GROG. Although GROG can be used to grid undersampled datasets, it is important to note that this method uses parallel imaging only for gridding, and not to reconstruct artifact-free images from undersampled data. Thereafter a simple, novel method for performing modified Cartesian GRAPPA reconstructions on undersampled non-Cartesian k-space data gridded using GROG to arrive at a non-aliased image is introduced. Because the undersampled non-Cartesian data cannot be reconstructed using a single GRAPPA kernel, several Cartesian patterns are selected for the reconstruction. Finally a novel method of using GROG to mimic the bunched phase encoding acquisition (BPE) scheme is discussed. In MRI, it is generally assumed that an artifact-free image can be reconstructed only from sampled points which fulfill the Nyquist criterion. However, the BPE reconstruction is based on the Generalized Sampling Theorem of Papoulis, which states that a continuous signal can be reconstructed from sampled points as long as the points are on average sampled at the Nyquist frequency. A novel

  8. Advances in non-Cartesian parallel magnetic resonance imaging using the GRAPPA operator

    International Nuclear Information System (INIS)

    Seiberlich, Nicole

    2008-01-01

    This thesis has presented several new non-Cartesian parallel imaging methods which simplify both gridding and the reconstruction of images from undersampled data. A novel approach which uses the concepts of parallel imaging to grid data sampled along a non-Cartesian trajectory called GRAPPA Operator Gridding (GROG) is described. GROG shifts any acquired k-space data point to its nearest Cartesian location, thereby converting non-Cartesian to Cartesian data. The only requirements for GROG are a multi-channel acquisition and a calibration dataset for the determination of the GROG weights. Then an extension of GRAPPA Operator Gridding, namely Self-Calibrating GRAPPA Operator Gridding (SC-GROG) is discussed. SC-GROG is a method by which non-Cartesian data can be gridded using spatial information from a multi-channel coil array without the need for an additional calibration dataset, as required in standard GROG. Although GROG can be used to grid undersampled datasets, it is important to note that this method uses parallel imaging only for gridding, and not to reconstruct artifact-free images from undersampled data. Thereafter a simple, novel method for performing modified Cartesian GRAPPA reconstructions on undersampled non-Cartesian k-space data gridded using GROG to arrive at a non-aliased image is introduced. Because the undersampled non-Cartesian data cannot be reconstructed using a single GRAPPA kernel, several Cartesian patterns are selected for the reconstruction. Finally a novel method of using GROG to mimic the bunched phase encoding acquisition (BPE) scheme is discussed. In MRI, it is generally assumed that an artifact-free image can be reconstructed only from sampled points which fulfill the Nyquist criterion. However, the BPE reconstruction is based on the Generalized Sampling Theorem of Papoulis, which states that a continuous signal can be reconstructed from sampled points as long as the points are on average sampled at the Nyquist frequency. A novel

  9. Study, development and clinical evaluation of a per-operative γ imager

    International Nuclear Information System (INIS)

    Menard, Laurent

    1999-01-01

    The precise localization and complete surgical ablation of tumors are one of the most important procedures in cancer treatment. In that context, the use, in operating room, of light hand-held detectors associated to radiopharmaceutical compounds for tumor labelling, plays a significant role in assisting surgeons in real-time detection of lesion. The POCI gamma imaging probe (Per-Operative Compact Imager), which is presented here, is precisely dedicated to improve the radio-guided operative cancer surgery efficiency by bringing a new tool discriminating between healthy and pathological tissues. To match the specifications of intra-operative detection, we chose to build our camera around an intensified position sensitive diode which appeared to be particularly suitable to achieve a high resolution small size imager. The optimal geometry of two gamma detection head modules, composed of parallel hole collimators and scintillation crystals, was then investigated by numerical simulations. From these technological solutions, a first prototype of POCI with a 24 mm diameter field of view has been developed. Its characterization has put forward a millimeter spatial resolution and a detection efficiency comparable to that of clinical gamma cameras and in agreement with the numerical predictions. Finally, in collaboration with Gustave Roussy, a first clinical evaluation of the POCI camera has been performed for sentinel ganglion pre-operative localization in patients afflicted by malignant melanomas or breast cancers. The preliminary results have already shown that the performances of POCI are compatible with intraoperative imaging purposes and suggest how this camera can boost the success rate of tumor removal surgeries for other cancerous diseases. (author)

  10. Recent operational performance of the CERN Omega Ring Imaging Cerenkov Detector

    International Nuclear Information System (INIS)

    Apsimon, R.J.; Flower, P.S.; Freeston, K.A.

    1985-10-01

    We discuss the design and construction of the Time Projection chambers (TPCs) of the Omega Ring Imaging Cerenkov Detector (RICH). Details are given of the TPC high voltage system and its monitoring and control. In addition, the operation and monitoring of the readout is described together with results of tests on the performance of the front end amplifiers. The operation of the RICH TPCs and electronics during the first data run of WA69, in 1984, is discussed together with relevant results from laboratory tests. Results from the preliminary analysis of a sample of data from the 1984 run are also presented

  11. Fusion of MultiSpectral and Panchromatic Images Based on Morphological Operators.

    Science.gov (United States)

    Restaino, Rocco; Vivone, Gemine; Dalla Mura, Mauro; Chanussot, Jocelyn

    2016-04-20

    Nonlinear decomposition schemes constitute an alternative to classical approaches for facing the problem of data fusion. In this paper we discuss the application of this methodology to a popular remote sensing application called pansharpening, which consists in the fusion of a low resolution multispectral image and a high resolution panchromatic image. We design a complete pansharpening scheme based on the use of morphological half gradients operators and demonstrate the suitability of this algorithm through the comparison with state of the art approaches. Four datasets acquired by the Pleiades, Worldview-2, Ikonos and Geoeye-1 satellites are employed for the performance assessment, testifying the effectiveness of the proposed approach in producing top-class images with a setting independent of the specific sensor.

  12. Pulsed operation of high-power light emitting diodes for imaging flow velocimetry

    International Nuclear Information System (INIS)

    Willert, C; Klinner, J; Moessner, S; Stasicki, B

    2010-01-01

    High-powered light emitting diodes (LED) are investigated for possible uses as light sources in flow diagnostics, in particular, as an alternative to laser-based illumination in particle imaging flow velocimetry in side-scatter imaging arrangements. Recent developments in solid state illumination resulted in mass-produced LEDs that provide average radiant power in excess of 10 W. By operating these LEDs with short duration, pulsed currents that are considerably beyond their continuous current damage threshold, light pulses can be generated that are sufficient to illuminate and image micron-sized particles in flow velocimetry. Time-resolved PIV measurements in water at a framing rate of 2kHz are presented. The feasibility of LED-based PIV measurements in air is also demonstrated

  13. Is pre-operative imaging essential prior to ureteric stone surgery?

    Science.gov (United States)

    Youssef, F R; Wilkinson, B A; Hastie, K J; Hall, J

    2012-09-01

    The aim of this study was to identify patients not requiring ureteric stone surgery based on pre-operative imaging (within 24 hours) prior to embarking on semirigid ureteroscopy (R-URS) for urolithiasis. The imaging of all consecutive patients on whom R-URS for urolithiasis was performed over a 12-month period was reviewed. All patients had undergone a plain x-ray of the kidney, ureters and bladder (KUB), abdominal non-contrast computed tomography (NCCT-KUB) or both on the day of surgery. A total of 96 patients were identified for the study. Stone sizes ranged from 3 mm to 20 mm. Thirteen patients (14%) were cancelled as no stone(s) were identified on pre-operative imaging. Of the patients cancelled, 8 (62%) required NCCT-KUB to confirm spontaneous stone passage. One in seven patients were stone free on the day of surgery. This negates the need for unnecessary anaesthetic and instrumentation of the urinary tract, with the associated morbidity. Up-to-date imaging prior to embarking on elective ureteric stone surgery is highly recommended.

  14. Intra-operative 3D imaging system for robot-assisted fracture manipulation.

    Science.gov (United States)

    Dagnino, G; Georgilas, I; Tarassoli, P; Atkins, R; Dogramadzi, S

    2015-01-01

    Reduction is a crucial step in the treatment of broken bones. Achieving precise anatomical alignment of bone fragments is essential for a good fast healing process. Percutaneous techniques are associated with faster recovery time and lower infection risk. However, deducing intra-operatively the desired reduction position is quite challenging due to the currently available technology. The 2D nature of this technology (i.e. the image intensifier) doesn't provide enough information to the surgeon regarding the fracture alignment and rotation, which is actually a three-dimensional problem. This paper describes the design and development of a 3D imaging system for the intra-operative virtual reduction of joint fractures. The proposed imaging system is able to receive and segment CT scan data of the fracture, to generate the 3D models of the bone fragments, and display them on a GUI. A commercial optical tracker was included into the system to track the actual pose of the bone fragments in the physical space, and generate the corresponding pose relations in the virtual environment of the imaging system. The surgeon virtually reduces the fracture in the 3D virtual environment, and a robotic manipulator connected to the fracture through an orthopedic pin executes the physical reductions accordingly. The system is here evaluated through fracture reduction experiments, demonstrating a reduction accuracy of 1.04 ± 0.69 mm (translational RMSE) and 0.89 ± 0.71 ° (rotational RMSE).

  15. Image segmentation of overlapping leaves based on Chan–Vese model and Sobel operator

    Directory of Open Access Journals (Sweden)

    Zhibin Wang

    2018-03-01

    Full Text Available To improve the segmentation precision of overlapping crop leaves, this paper presents an effective image segmentation method based on the Chan–Vese model and Sobel operator. The approach consists of three stages. First, a feature that identifies hues with relatively high levels of green is used to extract the region of leaves and remove the background. Second, the Chan–Vese model and improved Sobel operator are implemented to extract the leaf contours and detect the edges, respectively. Third, a target leaf with a complex background and overlapping is extracted by combining the results obtained by the Chan–Vese model and Sobel operator. To verify the effectiveness of the proposed algorithm, a segmentation experiment was performed on 30 images of cucumber leaf. The mean error rate of the proposed method is 0.0428, which is a decrease of 6.54% compared with the mean error rate of the level set method. Experimental results show that the proposed method can accurately extract the target leaf from cucumber leaf images with complex backgrounds and overlapping regions.

  16. Landsat 8 Operational Land Imager On-Orbit Geometric Calibration and Performance

    Directory of Open Access Journals (Sweden)

    James Storey

    2014-11-01

    Full Text Available The Landsat 8 spacecraft was launched on 11 February 2013 carrying the Operational Land Imager (OLI payload for moderate resolution imaging in the visible, near infrared (NIR, and short-wave infrared (SWIR spectral bands. During the 90-day commissioning period following launch, several on-orbit geometric calibration activities were performed to refine the prelaunch calibration parameters. The results of these calibration activities were subsequently used to measure geometric performance characteristics in order to verify the OLI geometric requirements. Three types of geometric calibrations were performed including: (1 updating the OLI-to-spacecraft alignment knowledge; (2 refining the alignment of the sub-images from the multiple OLI sensor chips; and (3 refining the alignment of the OLI spectral bands. The aspects of geometric performance that were measured and verified included: (1 geolocation accuracy with terrain correction, but without ground control (L1Gt; (2 Level 1 product accuracy with terrain correction and ground control (L1T; (3 band-to-band registration accuracy; and (4 multi-temporal image-to-image registration accuracy. Using the results of the on-orbit calibration update, all aspects of geometric performance were shown to meet or exceed system requirements.

  17. Conscious sedation for awake craniotomy in intraoperative magnetic resonance imaging operating theater

    Science.gov (United States)

    Takrouri, Mohamad Said Maani; Shubbak, Firas A.; Al Hajjaj, Aisha; Maestro, Rolando F. Del; Soualmi, Lahbib; Alkhodair, Mashael H.; Alduraiby, Abrar M.; Ghanem, Najeeb

    2010-01-01

    This case report describes the first case in intraoperative magnetic resonance imaging operating theater (iMRI OT) (BrainSuite®) of awake craniotomy for frontal lobe glioma excision in a 24-year-old man undergoing eloquent cortex language mapping intraoperatively. As he was very motivated to take pictures of him while being operated upon, the authors adapted conscious sedation technique with variable depth according to Ramsey's scale, in order to revert to awake state to perform the intended neurosurgical procedure. The patient tolerated the situation satisfactorily and was cooperative till the finish, without any event. We elicit in this report the special environment of iMRI OT for lengthy operation in pinned fixed patient having craniotomy. PMID:25885085

  18. Receiver operating characteristic analysis for the detection of simulated microcalcifications on mammograms using hardcopy images

    International Nuclear Information System (INIS)

    Lai, C J; Shaw, Chris C; Whitman, Gary J; Yang, Wei T; Dempsey, Peter J; Nguyen, Victoria; Ice, Mary F

    2006-01-01

    The aim of this study was to compare mammography systems based on three different detectors-a conventional screen-film (SF) combination, an a-Si/CsI flat-panel (FP)-based detector, and a charge-coupled device (CCD)-based x-ray phosphor-based detector-for their performance in detecting simulated microcalcifications (MCs). 112-150 μm calcium carbonate grains were used to simulate MCs and were overlapped with a slab phantom of simulated 50% adipose/50% glandular breast tissue-equivalent material referred to as the uniform background. For the tissue structure background, 200-250 μm calcium carbonate grains were used and overlapped with an anthropomorphic breast phantom. All MC phantom images were acquired with and without magnification (1.8X). The hardcopy images were reviewed by five mammographers. A five-point confidence level rating was used to score each detection task. Receiver operating characteristic (ROC) analysis was performed, and the areas under the ROC curves (A z s) were used to compare the performances of the three mammography systems under various conditions. The results showed that, with a uniform background and contact images, the FP-based system performed significantly better than the SF and the CCD-based systems. For magnified images with a uniform background, the SF and the FP-based systems performed equally well and significantly better than the CCD-based system. With tissue structure background and contact images, the SF system performed significantly better than the FP and the CCD-based systems. With magnified images and a tissue structure background, the SF and the CCD-based systems performed equally well and significantly better than the FP-based system. In the detection of MCs in the fibroglandular and the heterogeneously dense regions, no significant differences were found except that the SF system performed significantly better than the CCD-based system in the fibroglandular regions for the contact images

  19. Intra-operative adjustment of standard planes in C-arm CT image data.

    Science.gov (United States)

    Brehler, Michael; Görres, Joseph; Franke, Jochen; Barth, Karl; Vetter, Sven Y; Grützner, Paul A; Meinzer, Hans-Peter; Wolf, Ivo; Nabers, Diana

    2016-03-01

    With the help of an intra-operative mobile C-arm CT, medical interventions can be verified and corrected, avoiding the need for a post-operative CT and a second intervention. An exact adjustment of standard plane positions is necessary for the best possible assessment of the anatomical regions of interest but the mobility of the C-arm causes the need for a time-consuming manual adjustment. In this article, we present an automatic plane adjustment at the example of calcaneal fractures. We developed two feature detection methods (2D and pseudo-3D) based on SURF key points and also transferred the SURF approach to 3D. Combined with an atlas-based registration, our algorithm adjusts the standard planes of the calcaneal C-arm images automatically. The robustness of the algorithms is evaluated using a clinical data set. Additionally, we tested the algorithm's performance for two registration approaches, two resolutions of C-arm images and two methods for metal artifact reduction. For the feature extraction, the novel 3D-SURF approach performs best. As expected, a higher resolution ([Formula: see text] voxel) leads also to more robust feature points and is therefore slightly better than the [Formula: see text] voxel images (standard setting of device). Our comparison of two different artifact reduction methods and the complete removal of metal in the images shows that our approach is highly robust against artifacts and the number and position of metal implants. By introducing our fast algorithmic processing pipeline, we developed the first steps for a fully automatic assistance system for the assessment of C-arm CT images.

  20. [Handling modern imaging procedures in a high-tech operating room].

    Science.gov (United States)

    Hüfner, T; Citak, M; Imrecke, J; Krettek, C; Stübig, T

    2012-03-01

    Operating rooms are the central unit in the hospital network in trauma centers. In this area, high costs but also high revenues are generated. Modern operating theater concepts as an integrated model have been offered by different companies since the early 2000s. Our hypothesis is that integrative concepts for operating rooms, in addition to improved operating room ergonomics, have the potential for measurable time and cost savings. In our clinic, an integrated operating room concept (I-Suite, Stryker, Duisburg) was implemented after analysis of the problems. In addition to the ceiling-mounted arrangement, the system includes an endoscopy unit, a navigation system, and a voice control system. In the first 6 months (9/2005 to 2/2006), 112 procedures were performed in the integrated operating room: 34 total knee arthroplasties, 12 endoscopic spine surgeries, and 66 inpatient arthroscopic procedures (28 shoulder and 38 knee reconstructions). The analysis showed a daily saving of 22-45 min, corresponding to 15-30% of the daily changeover times, calculated to account for potential savings in the internal cost allocation of 225-450 EUR. A commercial operating room concept was evaluated in a pilot phase in terms of hard data, including time and cost factors. Besides the described effects further savings might be achieved through the effective use of voice control and the benefit of the sterile handle on the navigation camera, since waiting times for an additional nurse are minimized. The time of the procedure of intraoperative imaging is also reduced due to the ceiling-mounted concept, as the C-arm can be moved freely in the operating theater without hindering cables. By these measures and ensuing improved efficiency, the initial high costs for the implementation of the system may be cushioned over time.

  1. Predicting tool life in turning operations using neural networks and image processing

    Science.gov (United States)

    Mikołajczyk, T.; Nowicki, K.; Bustillo, A.; Yu Pimenov, D.

    2018-05-01

    A two-step method is presented for the automatic prediction of tool life in turning operations. First, experimental data are collected for three cutting edges under the same constant processing conditions. In these experiments, the parameter of tool wear, VB, is measured with conventional methods and the same parameter is estimated using Neural Wear, a customized software package that combines flank wear image recognition and Artificial Neural Networks (ANNs). Second, an ANN model of tool life is trained with the data collected from the first two cutting edges and the subsequent model is evaluated on two different subsets for the third cutting edge: the first subset is obtained from the direct measurement of tool wear and the second is obtained from the Neural Wear software that estimates tool wear using edge images. Although the complete-automated solution, Neural Wear software for tool wear recognition plus the ANN model of tool life prediction, presented a slightly higher error than the direct measurements, it was within the same range and can meet all industrial requirements. These results confirm that the combination of image recognition software and ANN modelling could potentially be developed into a useful industrial tool for low-cost estimation of tool life in turning operations.

  2. Utility of Early Post-operative High Resolution Volumetric MR Imaging after Transsphenoidal Pituitary Tumor Surgery

    Science.gov (United States)

    Patel, Kunal S.; Kazam, Jacob; Tsiouris, Apostolos J.; Anand, Vijay K.; Schwartz, Theodore H.

    2014-01-01

    Objective Controversy exists over the utility of early post-operative magnetic resonance imaging (MRI) after transsphenoidal pituitary surgery for macroadenomas. We investigate whether valuable information can be derived from current higher resolution scans. Methods Volumetric MRI scans were obtained in the early (30 days) post-operative periods in a series of patients undergoing transsphenoidal pituitary surgery. The volume of the residual tumor, resection cavity, and corresponding visual field tests were recorded at each time point. Statistical analyses of changes in tumor volume and cavity size were calculated using the late MRI as the gold standard. Results 40 patients met the inclusion criteria. Pre-operative tumor volume averaged 8.8 cm3. Early postoperative assessment of average residual tumor volume (1.18 cm3) was quite accurate and did not differ statistically from late post-operative volume (1.23 cm3, p=.64), indicating the utility of early scans to measure residual tumor. Early scans were 100% sensitive and 91% specific for predicting ≥ 98% resection (psurgery and a lack of decrease should alert the surgeon to possible persistent compression of the optic apparatus that may warrant re-operation. PMID:25045791

  3. Color Image Encryption Using Three-Dimensional Sine ICMIC Modulation Map and DNA Sequence Operations

    Science.gov (United States)

    Liu, Wenhao; Sun, Kehui; He, Yi; Yu, Mengyao

    Derived from Sine map and iterative chaotic map with infinite collapse (ICMIC), a three-dimensional hyperchaotic Sine ICMIC modulation map (3D-SIMM) is proposed based on a close-loop modulation coupling (CMC) method. Based on this map, a novel color image encryption algorithm is designed by employing a hybrid model of multidirectional circular permutation and deoxyribonucleic acid (DNA) masking. In this scheme, the pixel positions of image are scrambled by multidirectional circular permutation, and the pixel values are substituted by DNA sequence operations. The simulation results and security analysis show that the algorithm has good encryption effect and strong key sensitivity, and can resist brute-force, statistical, differential, known-plaintext and chosen-plaintext attacks.

  4. Magnetic resonance imaging assessment of a sinus lift operation using reoxidised cellulose (Surgicel) as graft material.

    Science.gov (United States)

    Gray, C F; Redpath, T W; Bainton, R; Smith, F W

    2001-10-01

    Various materials have been used for bone grafts in the sinus lift operation, to increase the vertical bone height in the maxilla before the placement of dental implants in the atrophic maxilla. In this case history, Surgicel (oxidised regenerated cellulose) was used as a graft material for one patient, allowing successful delayed implant placement within new and existing bone. The sinus region was examined three months after grafting with Surgicel using magnetic resonance imaging (MRI). The MR images showed that material of similar MR signal to bone had formed within the graft. MRI allowed us to gain tomographic information of the region without exposure of the patient to ionising radiation. The formation of bone within the Surgicel matrix was confirmed at implant placement. This poses interesting questions as to the physiology of bone formation within non-particulate graft material, warranting further investigation.

  5. Image Quality Modeling and Characterization of Nyquist Sampled Framing Systems with Operational Considerations for Remote Sensing

    Science.gov (United States)

    Garma, Rey Jan D.

    The trade between detector and optics performance is often conveyed through the Q metric, which is defined as the ratio of detector sampling frequency and optical cutoff frequency. Historically sensors have operated at Q ≈ 1, which introduces aliasing but increases the system modulation transfer function (MTF) and signal-to-noise ratio (SNR). Though mathematically suboptimal, such designs have been operationally ideal when considering system parameters such as pointing stability and detector performance. Substantial advances in read noise and quantum efficiency of modern detectors may compensate for the negative aspects associated with balancing detector/optics performance, presenting an opportunity to revisit the potential for implementing Nyquist-sampled (Q ≈ 2) sensors. A digital image chain simulation is developed and validated against a laboratory testbed using objective and subjective assessments. Objective assessments are accomplished by comparison of the modeled MTF and measurements from slant-edge photographs. Subjective assessments are carried out by performing a psychophysical study where subjects are asked to rate simulation and testbed imagery against a DeltaNIIRS scale with the aid of a marker set. Using the validated model, additional test cases are simulated to study the effects of increased detector sampling on image quality with operational considerations. First, a factorial experiment using Q-sampling, pointing stability, integration time, and detector performance is conducted to measure the main effects and interactions of each on the response variable, DeltaNIIRS. To assess the fidelity of current models, variants of the General Image Quality Equation (GIQE) are evaluated against subject-provided ratings and two modified GIQE versions are proposed. Finally, using the validated simulation and modified IQE, trades are conducted to ascertain the feasibility of implementing Q ≈ 2 designs in future systems.

  6. Grafting polyethylenimine with quinoline derivatives for targeted imaging of intracellular Zn2+ and logic gate operations

    International Nuclear Information System (INIS)

    Pan, Yi; Shi, Yupeng; Chen, Junying; Wong, Chap-Mo; Zhang, Heng; Li, Mei-Jin; Li, Cheuk-Wing; Yi, Changqing

    2016-01-01

    In this study, a highly sensitive and selective fluorescent Zn 2+ probe which exhibited excellent biocompatibility, water solubility, and cell-membrane permeability, was facilely synthesized in a single step by grafting polyethyleneimine (PEI) with quinoline derivatives. The primary amino groups in the branched PEI can increase water solubility and cell permeability of the probe PEIQ, while quinoline derivatives can specifically recognize Zn 2+ and reduce the potential cytotoxicity of PEI. Basing on fluorescence off-on mechanism, PEIQ demonstrated excellent sensing capability towards Zn 2+ in absolute aqueous solution, where a high sensitivity with a detection limit as low as 38.1 nM, and a high selectivity over competing metal ions and potential interfering amino acids, were achieved. Inspired by these results, elementary logic operations (YES, NOT and INHIBIT) have been constructed by employing PEIQ as the gate while Zn 2+ and EDTA as chemical inputs. Together with the low cytotoxicity and good cell-permeability, the practical application of PEIQ in living cell imaging was satisfactorily demonstrated, emphasizing its wide application in fundamental biology research. - Graphical abstract: The fluorescent Zn 2+ probe, PEIQ, is facilely synthesized by grafting PEI with 8-CAAQ, and demonstrated for the pratical applications in Zn 2+ imaging and implementation of molecular logic operations within biological cells. - Highlights: • PEIQ, fluorescent Zn 2+ probe, is synthesized by grafting PEI with quinoline derivatives. • PEIQ exhibits high sensitivity and selectivity in absolute aqueous solution. • PEIQ is biocompatible, water soluble, and cell-membrane permeable. • Elementary logic operations have been demonstrated for PEIQ/Zn 2+ /EDTA system. • The practical application of PEIQ in living cell imaging is demonstrated.

  7. Evaluating fuzzy operators of an object-based image analysis for detecting landslides and their changes

    Science.gov (United States)

    Feizizadeh, Bakhtiar; Blaschke, Thomas; Tiede, Dirk; Moghaddam, Mohammad Hossein Rezaei

    2017-09-01

    This article presents a method of object-based image analysis (OBIA) for landslide delineation and landslide-related change detection from multi-temporal satellite images. It uses both spatial and spectral information on landslides, through spectral analysis, shape analysis, textural measurements using a gray-level co-occurrence matrix (GLCM), and fuzzy logic membership functionality. Following an initial segmentation step, particular combinations of various information layers were investigated to generate objects. This was achieved by applying multi-resolution segmentation to IRS-1D, SPOT-5, and ALOS satellite imagery in sequential steps of feature selection and object classification, and using slope and flow direction derivatives from a digital elevation model together with topographically-oriented gray level co-occurrence matrices. Fuzzy membership values were calculated for 11 different membership functions using 20 landslide objects from a landslide training data. Six fuzzy operators were used for the final classification and the accuracies of the resulting landslide maps were compared. A Fuzzy Synthetic Evaluation (FSE) approach was adapted for validation of the results and for an accuracy assessment using the landslide inventory database. The FSE approach revealed that the AND operator performed best with an accuracy of 93.87% for 2005 and 94.74% for 2011, closely followed by the MEAN Arithmetic operator, while the OR and AND (*) operators yielded relatively low accuracies. An object-based change detection was then applied to monitor landslide-related changes that occurred in northern Iran between 2005 and 2011. Knowledge rules to detect possible landslide-related changes were developed by evaluating all possible landslide-related objects for both time steps.

  8. Framework for a low-cost intra-operative image-guided neuronavigator including brain shift compensation

    OpenAIRE

    Bucki, Marek; Lobos, Claudio; Payan, Yohan

    2007-01-01

    In this paper we present a methodology to address the problem of brain tissue deformation referred to as 'brain-shift'. This deformation occurs throughout a neurosurgery intervention and strongly alters the accuracy of the neuronavigation systems used to date in clinical routine which rely solely on pre-operative patient imaging to locate the surgical target, such as a tumour or a functional area. After a general description of the framework of our intra-operative image-guided system, we desc...

  9. Autonomous Diagnostic Imaging Performed by Untrained Operator Using Augmented Reality as a Form of "Just-in-Time" Training

    Science.gov (United States)

    Martin, David S.; Wang, Lui; Laurie, Steven S.; Lee, Stuart M. C.; Stenger, Michael B.

    2017-01-01

    We will address the Human Factors and Performance Team, "Risk of performance errors due to training deficiencies" by improving the JIT training materials for ultrasound and OCT imaging by providing advanced guidance in a detailed, timely, and user-friendly manner. Specifically, we will (1) develop an audio-visual tutorial using AR that guides non-experts through an abdominal trauma ultrasound protocol; (2) develop an audio-visual tutorial using AR to guide an untrained operator through the acquisition of OCT images; (3) evaluate the quality of abdominal ultrasound and OCT images acquired by untrained operators using AR guidance compared to images acquired using traditional JIT techniques (laptop-based training conducted before image acquisition); and (4) compare the time required to complete imaging studies using AR tutorials with images acquired using current JIT practices to identify areas for time efficiency improvements. Two groups of subjects will be recruited to participate in this study. Operator-subjects, without previous experience in ultrasound or OCT, will be asked to perform both procedures using either the JIT training with AR technology or the traditional JIT training via laptop. Images acquired by inexperienced operator-subjects will be scored by experts in that imaging modality for diagnostic and research quality; experts will be blinded to the form of JIT used to acquire the images. Operator-subjects also will be asked to submit feedback to improve the training modules used during the scans to improve future training modules. Scanned-subjects will be a small group individuals from whom all images will be acquired.

  10. Autonomous Diagnostic Imaging Performed by Untrained Operators using Augmented Reality as a Form of "Just-in-Time" Training

    Science.gov (United States)

    Martin, D. S.; Wang, L.; Laurie, S. S.; Lee, S. M. C.; Fleischer, A. C.; Gibson, C. R.; Stenger, M. B.

    2017-01-01

    We will address the Human Factors and Performance Team, "Risk of performance errors due to training deficiencies" by improving the JIT training materials for ultrasound and OCT imaging by providing advanced guidance in a detailed, timely, and user-friendly manner. Specifically, we will (1) develop an audio-visual tutorial using AR that guides non-experts through an abdominal trauma ultrasound protocol; (2) develop an audio-visual tutorial using AR to guide an untrained operator through the acquisition of OCT images; (3) evaluate the quality of abdominal ultrasound and OCT images acquired by untrained operators using AR guidance compared to images acquired using traditional JIT techniques (laptop-based training conducted before image acquisition); and (4) compare the time required to complete imaging studies using AR tutorials with images acquired using current JIT practices to identify areas for time efficiency improvements. Two groups of subjects will be recruited to participate in this study. Operator-subjects, without previous experience in ultrasound or OCT, will be asked to perform both procedures using either the JIT training with AR technology or the traditional JIT training via laptop. Images acquired by inexperienced operator-subjects will be scored by experts in that imaging modality for diagnostic and research quality; experts will be blinded to the form of JIT used to acquire the images. Operator-subjects also will be asked to submit feedback to improve the training modules used during the scans to improve future training modules. Scanned-subjects will be a small group individuals from whom all images will be acquired.

  11. Hyperspectral Imager for the Coastal Ocean (HICO): Overview, Operational Updates, and Coastal Ocean Applications

    Science.gov (United States)

    Davis, Curtiss O.; Kappus, Mary E.; Bowles, Jeffrey H.; Evans, Cynthia A.; Stefanov, William L.

    2014-01-01

    The Hyperspectral Imager for the Coastal Ocean (HICO) was built to measure in-water properties of complex coastal regions. HICO enables synoptic coverage; 100-meter spatial resolution for sampling the variability and spatial irregularity of coastal waters; and high spectral resolution to untangle the signals from chlorophyll, colored dissolved organic matter, suspended sediments and varying bottom types. HICO was built by the Naval Research Laboratory, installed on the International Space Station (ISS) in September 2009, and operated for ONR for the first three years. In 2013, NASA assumed sponsorship of operations in order to leverage HICO's ability to address their Earth monitoring mission. This has opened up access of HICO data to the broad research community. Over 8000 images are now available on NASA's Ocean Color Website (http://oceancolor.gsfc.nasa.gov/cgi/browse.pl?sen=hi). Oregon State University's HICO website (http://hico.coas.oregonstate.edu) remains the portal for researchers to request new collections and access their requested data. We will present updates on HICO's calibration and improvements in geolocation and show examples of the use of HICO data to address issues in the coastal ocean and Great Lakes.

  12. Development of a muon radiographic imaging electronic board system for a stable solar power operation

    Science.gov (United States)

    Uchida, T.; Tanaka, H. K. M.; Tanaka, M.

    2010-02-01

    Cosmic-ray muon radiography is a method that is used to study the internal structure of volcanoes. We have developed a muon radiographic imaging board with a power consumption low enough to be powered by a small solar power system. The imaging board generates an angular distribution of the muons. Used for real-time reading, the method may facilitate the prediction of eruptions. For real-time observations, the Ethernet is employed, and the board works as a web server for a remote operation. The angular distribution can be obtained from a remote PC via a network using a standard web browser. We have collected and analyzed data obtained from a 3-day field study of cosmic-ray muons at a Satsuma-Iwojima volcano. The data provided a clear image of the mountain ridge as a cosmic-ray muon shadow. The measured performance of the system is sufficient for a stand-alone cosmic-ray muon radiography experiment.

  13. Design of a receiver operating characteristic (ROC) study of 10:1 lossy image compression

    Science.gov (United States)

    Collins, Cary A.; Lane, David; Frank, Mark S.; Hardy, Michael E.; Haynor, David R.; Smith, Donald V.; Parker, James E.; Bender, Gregory N.; Kim, Yongmin

    1994-04-01

    The digital archiving system at Madigan Army Medical Center (MAMC) uses a 10:1 lossy data compression algorithm for most forms of computed radiography. A systematic study on the potential effect of lossy image compression on patient care has been initiated with a series of studies focused on specific diagnostic tasks. The studies are based upon the receiver operating characteristic (ROC) method of analysis for diagnostic systems. The null hypothesis is that observer performance with approximately 10:1 compressed and decompressed images is not different from using original, uncompressed images for detecting subtle pathologic findings seen on computed radiographs of bone, chest, or abdomen, when viewed on a high-resolution monitor. Our design involves collecting cases from eight pathologic categories. Truth is determined by committee using confirmatory studies performed during routine clinical practice whenever possible. Software has been developed to aid in case collection and to allow reading of the cases for the study using stand-alone Siemens Litebox workstations. Data analysis uses two methods, ROC analysis and free-response ROC (FROC) methods. This study will be one of the largest ROC/FROC studies of its kind and could benefit clinical radiology practice using PACS technology. The study design and results from a pilot FROC study are presented.

  14. E2CAV, Pavement layer thickness estimation system based on image texture operators

    Directory of Open Access Journals (Sweden)

    Brayan Barrios Arcila

    2017-01-01

    Full Text Available Context: Public roads are an essential part of economic progress in any country; they are fundamental for increasing the efficiency on transportation of goods and are a remarkable source of employment. For its part, Colombia has few statistics on the condition of its roads; according with INVIAS the state of the roads in Colombia can be classified as “Very Good” (21.1%, “Good” (34.7%, and “Regular” or “Bad” (43.46%. Thus, from the point of view of pavement rehabilitation, it is worth securing the quality of those roads classified as “Regular” or “Bad”. Objective: In this paper we propose a system to estimate the thickness of the pavement layer using image segmentation methods. The pavement thickness is currently estimated using radars of terrestrial penetration, extraction of cores or making pips; and it is part of structural parameters in the systems of evaluation of pavement. Method: The proposed system is composed of a vertical movement control unit, which introduces a video scope into a small hole in the pavement, then the images are obtained and unified in a laptop. Finally, this mosaic is processed through texture operators to estimate the thickness of the pavement. Users can select between the Otsu method and Gabor filters to process the image data. Results: The results include laboratory and field tests; these tests show errors of 5.03% and 11.3%, respectively, in the thickness of the pavement. Conclusion: The proposed system is an attractive option for local estimation of pavement thickness, with minimal structural damage and less impact on mobility and number of operators.

  15. Acquisition performance of LAPAN-A3/IPB multispectral imager in real-time mode of operation

    Science.gov (United States)

    Hakim, P. R.; Permala, R.; Jayani, A. P. S.

    2018-05-01

    LAPAN-A3/IPB satellite was launched in June 2016 and its multispectral imager has been producing Indonesian coverage images. In order to improve its support for remote sensing application, the imager should produce images with high quality and quantity. To improve the quantity of LAPAN-A3/IPB multispectral image captured, image acquisition could be executed in real-time mode from LAPAN ground station in Bogor when the satellite passes west Indonesia region. This research analyses the performance of LAPAN-A3/IPB multispectral imager acquisition in real-time mode, in terms of image quality and quantity, under assumption of several on-board and ground segment limitations. Results show that with real-time operation mode, LAPAN-A3/IPB multispectral imager could produce twice as much as image coverage compare to recorded mode. However, the images produced in real-time mode will have slightly degraded quality due to image compression process involved. Based on several analyses that have been done in this research, it is recommended to use real-time acquisition mode whenever it possible, unless for some circumstances that strictly not allow any quality degradation of the images produced.

  16. A novel intra-operative positron imager for rapid localization of tumor margins

    Science.gov (United States)

    Sabet, Hamid; Stack, Brendan C.; Nagarkar, Vivek V.

    2014-03-01

    We have developed an intra-operative and compact imaging tool for surgeons to detect PET- positive lesions. Currently, most such probes on the market are non-imaging, and provide no ancillary information of surveyed areas, such as clear delineations of malignant tissues. Our probe consists of a novel hybrid scintillator coupled to a compact silicon photomultiplier (SiPM) array with associated front-end electronics encapsulated in an ergonomic housing. Pulse shape discrimination electronics has been implemented and integrated into the downstream data acquisition system. The hybrid scintillator consists of a 0.4 mm thick layer of CsI:Tl scintillator coupled to a 1 mm thick LYSO crystal. To achieve high spatial resolution, CsI:Tl is pixelated to 0.5×0.5 mm2 pixels using laser ablation technique. While CsI:Tl act as beta-sensitive scintillator, LYSO senses the gamma radiation and can be used to navigate the probe to the locations of interest. The gamma response is also subtracted from the beta image for improved SNR and contrast. To achieve accurate centroid position estimation and uniform beta sensitivity over the entire imaging area, the LYSO thickness is optimized such that it acts as scintillation light diffuser by spreading CsI:Tl light over multiple SiPM pixels. The results show that the response of the two scintillators exposed to radiation could be easily distinguished based on their pulse shapes. The probe's spatial resolution is beta radiation even in presence of strong gamma background.

  17. Discriminative Nonlinear Analysis Operator Learning: When Cosparse Model Meets Image Classification.

    Science.gov (United States)

    Wen, Zaidao; Hou, Biao; Jiao, Licheng

    2017-05-03

    Linear synthesis model based dictionary learning framework has achieved remarkable performances in image classification in the last decade. Behaved as a generative feature model, it however suffers from some intrinsic deficiencies. In this paper, we propose a novel parametric nonlinear analysis cosparse model (NACM) with which a unique feature vector will be much more efficiently extracted. Additionally, we derive a deep insight to demonstrate that NACM is capable of simultaneously learning the task adapted feature transformation and regularization to encode our preferences, domain prior knowledge and task oriented supervised information into the features. The proposed NACM is devoted to the classification task as a discriminative feature model and yield a novel discriminative nonlinear analysis operator learning framework (DNAOL). The theoretical analysis and experimental performances clearly demonstrate that DNAOL will not only achieve the better or at least competitive classification accuracies than the state-of-the-art algorithms but it can also dramatically reduce the time complexities in both training and testing phases.

  18. Laser vision seam tracking system based on image processing and continuous convolution operator tracker

    Science.gov (United States)

    Zou, Yanbiao; Chen, Tao

    2018-06-01

    To address the problem of low welding precision caused by the poor real-time tracking performance of common welding robots, a novel seam tracking system with excellent real-time tracking performance and high accuracy is designed based on the morphological image processing method and continuous convolution operator tracker (CCOT) object tracking algorithm. The system consists of a six-axis welding robot, a line laser sensor, and an industrial computer. This work also studies the measurement principle involved in the designed system. Through the CCOT algorithm, the weld feature points are determined in real time from the noise image during the welding process, and the 3D coordinate values of these points are obtained according to the measurement principle to control the movement of the robot and the torch in real time. Experimental results show that the sensor has a frequency of 50 Hz. The welding torch runs smoothly with a strong arc light and splash interference. Tracking error can reach ±0.2 mm, and the minimal distance between the laser stripe and the welding molten pool can reach 15 mm, which can significantly fulfill actual welding requirements.

  19. Post-operative cyst and orbital walls. A CT image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fukuta, Masahiro (Takeda General Hospital, Aizuwakamatsu, Fukushima (Japan)); Iinuma, Toshitaka

    1989-07-01

    A set of coronal CT images obtained by 118 sides (109 cases) of post-operative cysts of maxilla, seen from 1982 to 1988, was analyzed as to the orbital wall affections. Coronal images were grouped into five consecutive planes, i.e. the first plane being the one which is 5 mm posterior to the nasion, and the other planes in successive orders each being 5 mm apart. The orbital walls were classified into inferior, medial, and transition of these two. The orbital wall affections were classified into dehiscence, thinned-out (less than 1 mm), and normal. The orbital signs and symptoms (epiphora, pain, asthenopia, visual loss, diplopia, and exophthalmos) were analyzed based upon the questionnaires by patients. The inferior wall affections (dehiscence and thinned-out) were seen most often (57%) at the third plane (2 cm posterior to the nasion). The orbital signs and symptoms in general were seen in half of the cases of which 20% were of grave (visual loss, diplopia and exophthalmos). These signs and symptoms were the more often, the more anterior the site of affections located. Grave signs and symptoms were seen at 2 to 2.5 cm posterior to the nasion when the orbital floor was affected and the inferior rectus were either pushed up or in direct contact with the cysts. (author).

  20. The effects of body image impairment on the quality of life of non-operated Portuguese female IBD patients.

    Science.gov (United States)

    Trindade, Inês A; Ferreira, Cláudia; Pinto-Gouveia, José

    2017-02-01

    Inflammatory bowel diseases (IBD) and their treatment are known to negatively impact on patients' body image, especially female patients. However, although there are broad evidences of body image impairment in female IBD patients, its negative impact on the quality of life (QoL) of non-operated women is not clearly and specifically studied. The aim of the current study was therefore to analyse, in a sample of non-operated female IBD patients, the factors that contribute to body image impairment and its impact on QoL. Ninety-six non-operated women (39.7 % with CD and 60.3 % with UC), aged between 18 and 40 years old, completed an online survey with validated self-report measures, which included the Body Image Scale and the WHO Brief Quality of Life Assessment Scale. Negative body image was correlated with lower psychological and physical QoL and increased corticosteroids use, associated medical complications, body mass index (BMI), and IBD symptomatology. Regression analyses revealed that BMI and IBD symptomatology significantly predicted body image impairment. Furthermore, results from path analyses indicated that BMI and IBD symptomatology's effect on psychological and physical QoL was mediated through the negative effects of body image impairment. This model explained 31 % of psychological QoL and 41 % of physical QoL. These findings suggest that non-operated female patients are subject to pervasive and harmful effects of body image impairment on psychological and physical functioning. Therefore, psychological interventions aiming to target body dissatisfaction should be implemented in the health care of IBD, independently of patients' operative status.

  1. Microaneurysms detection with the radon cliff operator in retinal fundus images

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Tobin Jr, Kenneth William [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2010-01-01

    Diabetic Retinopathy (DR) is one of the leading causes of blindness in the industrialized world. Early detection is the key in providing effective treatment. However, the current number of trained eye care specialists is inadequate to screen the increasing number of diabetic patients. In recent years, automated and semi-automated systems to detect DR with color fundus images have been developed with encouraging, but not fully satisfactory results. In this study we present the initial results of a new technique for the detection and localization of microaneurysms, an early sign of DR. The algorithm is based on three steps: candidates selection, the actual microaneurysms detection and a final probability evaluation. We introduce the new Radon Cliff operator which is our main contribution to the field. Making use of the Radon transform, the operator is able to detect single noisy Gaussian-like circular structures regardless of their size or strength. The advantages over existing microaneurysms detectors are manifold: the size of the lesions can be unknown, it automatically distinguishes lesions from the vasculature and it provides a fair approach to microaneurysm localization even without post-processing the candidates with machine learning techniques, facilitating the training phase. The algorithm is evaluated on a publicly available dataset from the Retinopathy Online Challenge.

  2. Microaneurysms detection with the radon cliff operator in retinal fundus images

    Science.gov (United States)

    Giancardo, Luca; Mériaudeau, Fabrice; Karnowski, Thomas P.; Tobin, Kenneth W.; Li, Yaqin; Chaum, Edward

    2010-03-01

    Diabetic Retinopathy (DR) is one of the leading causes of blindness in the industrialized world. Early detection is the key in providing effective treatment. However, the current number of trained eye care specialists is inadequate to screen the increasing number of diabetic patients. In recent years, automated and semi-automated systems to detect DR with color fundus images have been developed with encouraging, but not fully satisfactory results. In this study we present the initial results of a new technique for the detection and localization of microaneurysms, an early sign of DR. The algorithm is based on three steps: candidates selection, the actual microaneurysms detection and a final probability evaluation. We introduce the new Radon Cliff operator which is our main contribution to the field. Making use of the Radon transform, the operator is able to detect single noisy Gaussian-like circular structures regardless of their size or strength. The advantages over existing microaneurysms detectors are manifold: the size of the lesions can be unknown, it automatically distinguishes lesions from the vasculature and it provides a fair approach to microaneurysm localization even without post-processing the candidates with machine learning techniques, facilitating the training phase. The algorithm is evaluated on a publicly available dataset from the Retinopathy Online Challenge.

  3. Knee dislocations: a magnetic resonance imaging study correlated with clinical and operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Bui, Kimmie L. [Cleveland Clinic, Department of Radiology, Cleveland, OH (United States); Cleveland Clinic, Department of Radiology, HB6, Cleveland, OH (United States); Ilaslan, Hakan; Sundaram, Murali [Cleveland Clinic, Department of Radiology, Cleveland, OH (United States); Parker, Richard D. [Cleveland Clinic, Department of Orthopaedics, Cleveland, OH (United States)

    2008-07-15

    Our objectives were to determine retrospectively the prevalence, patients' demographics, mechanism of injury, combination of torn ligaments, associated intra-articular and extra-articular injuries, fractures, bone bruises, femoral-tibial alignment and neurovascular complications of knee dislocations as evaluated by magnetic resonance (MR) imaging. From 17,698 consecutive knee examinations by magnetic resonance imaging (MRI) over a 6-year period, 20 patients with knee dislocations were identified. The medical records of these patients were subsequently reviewed for relevant clinical history, management and operative findings. The prevalence of knee dislocations was 0.11% [95% confidence interval (95% CI) 0.06-0.16]. There were 16 male patients and four female patients, with ages ranging from 15 years to 76 years (mean 31 years). Fifteen patients had low-velocity injuries (75%), of which 11 were amateur sports related and four were from falls. Four patients (20%) had suffered high-velocity trauma (motor vehicle accidents). One patient had no history available. Anatomic alignment was present at imaging in 16 patients (80%). Eighteen patients had three-ligament tears, two had four-ligament tears. The four-ligament tears occurred with low-velocity injuries. The anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) were torn in every patient; the lateral collateral ligament (LCL) was torn in 50%, and the medial collateral ligament (MCL) in 60%. Intra-articular injuries included meniscal tears (five in four patients), fractures (eight in seven patients), bone bruises (15 patients), and patellar retinaculum tears (eight partial, two complete). The most common extra-articular injury was a complete biceps femoris tendon tear (five, 25%). There were two popliteal tendon tears and one iliotibial band tear. One patient had received a vascular injury following a motor vehicle accident (MVA) and had been treated prior to undergoing MRI. Bone bruises

  4. Intra-operative fiducial-based CT/fluoroscope image registration framework for image-guided robot-assisted joint fracture surgery.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-08-01

    Joint fractures must be accurately reduced minimising soft tissue damages to avoid negative surgical outcomes. To this regard, we have developed the RAFS surgical system, which allows the percutaneous reduction of intra-articular fractures and provides intra-operative real-time 3D image guidance to the surgeon. Earlier experiments showed the effectiveness of the RAFS system on phantoms, but also key issues which precluded its use in a clinical application. This work proposes a redesign of the RAFS's navigation system overcoming the earlier version's issues, aiming to move the RAFS system into a surgical environment. The navigation system is improved through an image registration framework allowing the intra-operative registration between pre-operative CT images and intra-operative fluoroscopic images of a fractured bone using a custom-made fiducial marker. The objective of the registration is to estimate the relative pose between a bone fragment and an orthopaedic manipulation pin inserted into it intra-operatively. The actual pose of the bone fragment can be updated in real time using an optical tracker, enabling the image guidance. Experiments on phantom and cadavers demonstrated the accuracy and reliability of the registration framework, showing a reduction accuracy (sTRE) of about [Formula: see text] (phantom) and [Formula: see text] (cadavers). Four distal femur fractures were successfully reduced in cadaveric specimens using the improved navigation system and the RAFS system following the new clinical workflow (reduction error [Formula: see text], [Formula: see text]. Experiments showed the feasibility of the image registration framework. It was successfully integrated into the navigation system, allowing the use of the RAFS system in a realistic surgical application.

  5. Implementing a Parallel Image Edge Detection Algorithm Based on the Otsu-Canny Operator on the Hadoop Platform.

    Science.gov (United States)

    Cao, Jianfang; Chen, Lichao; Wang, Min; Tian, Yun

    2018-01-01

    The Canny operator is widely used to detect edges in images. However, as the size of the image dataset increases, the edge detection performance of the Canny operator decreases and its runtime becomes excessive. To improve the runtime and edge detection performance of the Canny operator, in this paper, we propose a parallel design and implementation for an Otsu-optimized Canny operator using a MapReduce parallel programming model that runs on the Hadoop platform. The Otsu algorithm is used to optimize the Canny operator's dual threshold and improve the edge detection performance, while the MapReduce parallel programming model facilitates parallel processing for the Canny operator to solve the processing speed and communication cost problems that occur when the Canny edge detection algorithm is applied to big data. For the experiments, we constructed datasets of different scales from the Pascal VOC2012 image database. The proposed parallel Otsu-Canny edge detection algorithm performs better than other traditional edge detection algorithms. The parallel approach reduced the running time by approximately 67.2% on a Hadoop cluster architecture consisting of 5 nodes with a dataset of 60,000 images. Overall, our approach system speeds up the system by approximately 3.4 times when processing large-scale datasets, which demonstrates the obvious superiority of our method. The proposed algorithm in this study demonstrates both better edge detection performance and improved time performance.

  6. An electronic image processing device featuring continuously selectable two-dimensional bipolar filter functions and real-time operation

    International Nuclear Information System (INIS)

    Charleston, B.D.; Beckman, F.H.; Franco, M.J.; Charleston, D.B.

    1981-01-01

    A versatile electronic-analogue image processing system has been developed for use in improving the quality of various types of images with emphasis on those encountered in experimental and diagnostic medicine. The operational principle utilizes spatial filtering which selectively controls the contrast of an image according to the spatial frequency content of relevant and non-relevant features of the image. Noise can be reduced or eliminated by selectively lowering the contrast of information in the high spatial frequency range. Edge sharpness can be enhanced by accentuating the upper midrange spatial frequencies. Both methods of spatial frequency control may be adjusted continuously in the same image to obtain maximum visibility of the features of interest. A precision video camera is used to view medical diagnostic images, either prints, transparencies or CRT displays. The output of the camera provides the analogue input signal for both the electronic processing system and the video display of the unprocessed image. The video signal input to the electronic processing system is processed by a two-dimensional spatial convolution operation. The system employs charged-coupled devices (CCDs), both tapped analogue delay lines (TADs) and serial analogue delay lines (SADs), to store information in the form of analogue potentials which are constantly being updated as new sampled analogue data arrive at the input. This information is convolved with a programmed bipolar radially symmetrical hexagonal function which may be controlled and varied at each radius by the operator in real-time by adjusting a set of front panel controls or by a programmed microprocessor control. Two TV monitors are used, one for processed image display and the other for constant reference to the original image. The working prototype has a full-screen display matrix size of 200 picture elements per horizontal line by 240 lines. The matrix can be expanded vertically and horizontally for the

  7. MO-DE-202-03: Image-Guided Surgery and Interventions in the Advanced Multimodality Image-Guided Operating (AMIGO) Suite

    Energy Technology Data Exchange (ETDEWEB)

    Kapur, T. [Brigham & Women’s Hospital (United States)

    2016-06-15

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guided neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504

  8. MO-DE-202-03: Image-Guided Surgery and Interventions in the Advanced Multimodality Image-Guided Operating (AMIGO) Suite

    International Nuclear Information System (INIS)

    Kapur, T.

    2016-01-01

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guided neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504

  9. Comparison of pre-operative dGEMRIC imaging with intra-operative findings in femoroacetabular impingement: preliminary findings

    International Nuclear Information System (INIS)

    Bittersohl, Bernd; Apprich, Sebastian; Siebenrock, Klaus A.; Mamisch, Tallal Charles; Hosalkar, Harish S.; Werlen, Stefan A.

    2011-01-01

    To study standard MRI and dGEMRIC in patients with symptomatic FAI undergoing surgical intervention and compare them with intra-operative findings to see if they were corroborative. Sixteen patients with symptomatic FAI that warranted surgical intervention were prospectively studied. All patients underwent plain radiographic series for FAI assessment followed by standard MRI and dGEMRIC. Subsequently, patients were surgically treated with safe dislocation and the joint was evaluated for any macroscopic signs of damaged cartilage. Data were statistically analyzed. A total of 224 zones in 16 patients were evaluated. One hundred and sixteen zones were intra-operatively rated as normal with mean T1 values of 510.1 ms ± 141.2 ms. Eighty zones had evidence of damage with mean T1 values of 453.1 ms ± 113.6 ms. The difference in these T1 values was significant (p = 0.003). Correlation between standard MRI and intra-operative findings was moderate (r = 0.535, p < 0.001). Intra-operative findings revealed more damage than standard MRI. On standard MRI, 68.6% zones were graded normal while 31.4% had evidence of damage. On intra-operative visualization, 56.4% zones were graded normal and 43.6% had evidence of damage. Correlation between dGEMRIC and intra-operative findings turned out to be weak (r = 0.114, p < 0.126). On T1 assessment 31.4% of zones were graded as normal and 68.6% as damaged. dGEMRIC was significantly different between normal and affected cartilage based on intra-operative assessment. The correlation for morphological findings was limited, underestimating defects. By combining morphological with biochemical assessment dGEMRIC may play some role in the future to prognosticate outcomes and facilitate surgical planning and intervention. (orig.)

  10. Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator.

    Science.gov (United States)

    Khazendar, S; Sayasneh, A; Al-Assam, H; Du, H; Kaijser, J; Ferrara, L; Timmerman, D; Jassim, S; Bourne, T

    2015-01-01

    Preoperative characterisation of ovarian masses into benign or malignant is of paramount importance to optimise patient management. In this study, we developed and validated a computerised model to characterise ovarian masses as benign or malignant. Transvaginal 2D B mode static ultrasound images of 187 ovarian masses with known histological diagnosis were included. Images were first pre-processed and enhanced, and Local Binary Pattern Histograms were then extracted from 2 × 2 blocks of each image. A Support Vector Machine (SVM) was trained using stratified cross validation with randomised sampling. The process was repeated 15 times and in each round 100 images were randomly selected. The SVM classified the original non-treated static images as benign or malignant masses with an average accuracy of 0.62 (95% CI: 0.59-0.65). This performance significantly improved to an average accuracy of 0.77 (95% CI: 0.75-0.79) when images were pre-processed, enhanced and treated with a Local Binary Pattern operator (mean difference 0.15: 95% 0.11-0.19, p images of ovarian masses into benign and malignant categories. The accuracy improves if texture related LBP features extracted from the images are considered.

  11. Modeling a color-rendering operator for high dynamic range images using a cone-response function

    Science.gov (United States)

    Choi, Ho-Hyoung; Kim, Gi-Seok; Yun, Byoung-Ju

    2015-09-01

    Tone-mapping operators are the typical algorithms designed to produce visibility and the overall impression of brightness, contrast, and color of high dynamic range (HDR) images on low dynamic range (LDR) display devices. Although several new tone-mapping operators have been proposed in recent years, the results of these operators have not matched those of the psychophysical experiments based on the human visual system. A color-rendering model that is a combination of tone-mapping and cone-response functions using an XYZ tristimulus color space is presented. In the proposed method, the tone-mapping operator produces visibility and the overall impression of brightness, contrast, and color in HDR images when mapped onto relatively LDR devices. The tone-mapping resultant image is obtained using chromatic and achromatic colors to avoid well-known color distortions shown in the conventional methods. The resulting image is then processed with a cone-response function wherein emphasis is placed on human visual perception (HVP). The proposed method covers the mismatch between the actual scene and the rendered image based on HVP. The experimental results show that the proposed method yields an improved color-rendering performance compared to conventional methods.

  12. SEGMENTATION AND CLASSIFICATION OF CERVICAL CYTOLOGY IMAGES USING MORPHOLOGICAL AND STATISTICAL OPERATIONS

    Directory of Open Access Journals (Sweden)

    S Anantha Sivaprakasam

    2017-02-01

    Full Text Available Cervical cancer that is a disease, in which malignant (cancer cells form in the tissues of the cervix, is one of the fourth leading causes of cancer death in female community worldwide. The cervical cancer can be prevented and/or cured if it is diagnosed in the pre-cancerous lesion stage or earlier. A common physical examination technique widely used in the screening is called Papanicolaou test or Pap test which is used to detect the abnormality of the cell. Due to intricacy of the cell nature, automating of this procedure is still a herculean task for the pathologist. This paper addresses solution for the challenges in terms of a simple and novel method to segment and classify the cervical cell automatically. The primary step of this procedure is pre-processing in which de-nosing, de-correlation operation and segregation of colour components are carried out, Then, two new techniques called Morphological and Statistical Edge based segmentation and Morphological and Statistical Region Based segmentation Techniques- put forward in this paper, and that are applied on the each component of image to segment the nuclei from cervical image. Finally, all segmented colour components are combined together to make a final segmentation result. After extracting the nuclei, the morphological features are extracted from the nuclei. The performance of two techniques mentioned above outperformed than standard segmentation techniques. Besides, Morphological and Statistical Edge based segmentation is outperformed than Morphological and Statistical Region based Segmentation. Finally, the nuclei are classified based on the morphological value The segmentation accuracy is echoed in classification accuracy. The overall segmentation accuracy is 97%.

  13. Elaboration and implementation of standard operational procedure for quality assurance of cone beam CT image in radiotherapy

    International Nuclear Information System (INIS)

    Bonatto, Larisse N.; Estacio, Daniela R.; Lopes, Juliane S.; Sansson, Angela; Duarte, Lucas O.; Sbaraini, Patricia; Silva, Ana M. Marques da; Streck, Elaine E.

    2016-01-01

    The objective of this article is to present the implementation of the quality Control of Cone Beam Computed Tomography (CBCT) image, generated by the On-Board Imager, integrated with the linear accelerator Trilogy. Standard operating procedures (POPs) have been developed based on the literature and manuals of the simulator object Catphan 504 and the On-Board Imager. The following POPs were developed: acquisition of the CBCT image; linearity of CT number; uniformity; spatial resolution; low contrast resolution; spatial linearity; thickness of the cut. The validation of the elaborated procedures was done from an experimental acquisition of the simulator object. The results obtained in the validation of the POPs are in compliance with the parameters established by the manufacturer of the simulator object, as well as those obtained in the acceptance of the On-Board Imager device.

  14. Data derandomizer and method of operation for radiation imaging detection systems

    International Nuclear Information System (INIS)

    Hatch, K.F.

    1977-01-01

    A nuclear imaging system includes an analog signal processor which features analog data derandomization for minimizing data loss due to pulse pile-up. A scintillation detector provides a sequence of analog data pulses to the signal processor, the data pulses characterizing the energy level and situs of respective radiation events striking the detector. The signal processor includes sets of novel peak detectors and of sample and hold circuits which are serially connected and are operated to derandomize or space the sequence of analog data pulses so that the system can process pulses corresponding to photopeak events occurring only 1.5 microseconds apart. The analog data pulses are stored in analog pulse form in the peak detectors and are selectively transferred into the sample and hold circuitry from which they are transferred to the display mechanism. The signal processor is multiplexed with several data input channels for accommodating dual isotope operation. A control unit is provided which controls the data processing cycle according to a predetermined processing time, or according to signals from external system apparatus. The control unit provides automatic resetting for assurance that the signal processor does not become locked into an inoperative, nondata processing state. The novel peak detectors are controlled by the control unit and feature input biasing for increased detection sensitivity, proportional dumping for discharging the stored peak value at a rate proportional to the value of the stored peak, and selective input data gating so that only the peak containing portion of the input signal is input into the detector. 28 claims, 10 figures

  15. Prediction of post-operative necrosis after mastectomy: A pilot study utilizing optical diffusion imaging spectroscopy

    Directory of Open Access Journals (Sweden)

    Xie Xian-Jin

    2009-11-01

    Full Text Available Abstract Introduction Flap necrosis and epidermolysis occurs in 18-30% of all mastectomies. Complications may be prevented by intra-operative detection of ischemia. Currently, no technique enables quantitative valuation of mastectomy skin perfusion. Optical Diffusion Imaging Spectroscopy (ViOptix T.Ox Tissue Oximeter measures the ratio of oxyhemoglobin to deoxyhemoglobin over a 1 × 1 cm area to obtain a non-invasive measurement of perfusion (StO2. Methods This study evaluates the ability of ViOptix T.Ox Tissue Oximeter to predict mastectomy flap necrosis. StO2 measurements were taken at five points before and at completion of dissection in 10 patients. Data collected included: demographics, tumor size, flap length/thickness, co-morbidities, procedure length, and wound complications. Results One patient experienced mastectomy skin flap necrosis. Five patients underwent immediate reconstruction, including the patient with necrosis. Statistically significant factors contributing to necrosis included reduction in medial flap StO2 (p = 0.0189, reduction in inferior flap StO2 (p = 0.003, and flap length (p = 0.009. Conclusion StO2 reductions may be utilized to identify impaired perfusion in mastectomy skin flaps.

  16. Near-infrared laparoscopy for real-time intra-operative arterial and lymphatic perfusion imaging.

    LENUS (Irish Health Repository)

    Cahill, R A

    2012-02-01

    Multimodal laparoscopic imaging systems possessing the capability for extended spectrum irradiation and visualization within a unified camera system are now available to provide enhanced intracorporeal operative anatomic and dynamic perfusion assessment and potentially augmented patient outcome. While ultraviolet-range energies have limited penetration and hence are probably more useful for endoscopic mucosal interrogation, the near-infrared (NIR) spectrum is of greater potential utility for the purposes of examining inducible fluorescence in abdominopelvic tissue that can be achieved by administration of specific tracer agents, either directly into the circulation (e.g. for anastomotic perfusion assessment at the time of stapling) or into the lymphatic system (e.g. for lymph basin road-mapping and\\/or focussed target nodal assessment). This technology is also capable of supplementing anatomic recognition of the biliary system while implantable fibres can also be inserted intraoperatively for the purpose of safeguarding vital structures such as the oesphagus and ureters especially in difficult reoperations. It is likely that this technological capability will find a clear and common indication in colorectal specialist and general surgical departments worldwide in the near future.

  17. Monitoring algal blooms in drinking water reservoirs using the Landsat-8 Operational Land Imager

    Science.gov (United States)

    Keith, Darryl; Rover, Jennifer; Green, Jason; Zalewsky, Brian; Charpentier, Mike; Hursby, Glen; Bishop, Joseph

    2018-01-01

    In this study, we demonstrated that the Landsat-8 Operational Land Imager (OLI) sensor is a powerful tool that can provide periodic and system-wide information on the condition of drinking water reservoirs. The OLI is a multispectral radiometer (30 m spatial resolution) that allows ecosystem observations at spatial and temporal scales that allow the environmental community and water managers another means to monitor changes in water quality not feasible with field-based monitoring. Using the provisional Land Surface Reflectance product and field-collected chlorophyll-a (chl-a) concentrations from drinking water monitoring programs in North Carolina and Rhode Island, we compared five established approaches for estimating chl-aconcentrations using spectral data. We found that using the three band reflectance approach with a combination of OLI spectral bands 1, 3, and 5 produced the most promising results for accurately estimating chl-a concentrations in lakes (R2 value of 0.66; root mean square error value of 8.9 µg l−1). Using this model, we forecast the spatial and temporal variability of chl-a for Jordan Lake, a recreational and drinking water source in piedmont North Carolina and several small ponds that supply drinking water in southeastern Rhode Island.

  18. Prospective evaluation of stress myocardial perfusion imaging for pre-operative cardiac risk assessment

    International Nuclear Information System (INIS)

    Byrne, A.J.; Rowe, C.C.; Flannery, G.

    2002-01-01

    Full text: A prospective evaluation of patients who underwent stress myocardial perfusion imaging (MPI) to assess preoperative cardiac risk was undertaken. At the time of the scan patients were classified into 4 Clinical Risk groups (CR) based on known clinical data. On completion of the scan, the patient was then categorised into 4 Scan based Risk groups (SR), incorporating size of perfusion deficit, single versus multi-vessel disease and ejection fraction. Surgery at Austin and Repatriation Medical Centre within 6 months of scan and complications were identified using the hospital medical database. Major early cardiac events coded were death (cardiac related), myocardial infarction, unstable angina, acute pulmonary oedema, cardiac arrest, and urgent revascularisation. 208 patients have reached 6 months post-MPI scan. Of these 119 (57%) were identified as having surgery. Of the Scan Risk groups, 63% of normal, 57% of increased, and 47% of high and very high groups have had surgery. An abnormal scan is associated with a three-fold risk of cardiac complication (3.5% vs 11.3%). This is lower than most previous reports and may be due to higher representation of low risk surgical procedures (14% in this series), improved peri-operative care and/or the test result influence on management (suggested by decreasing surgical rate as SR estimate rose). Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  19. Quantum Computation-Based Image Representation, Processing Operations and Their Applications

    Directory of Open Access Journals (Sweden)

    Fei Yan

    2014-10-01

    Full Text Available A flexible representation of quantum images (FRQI was proposed to facilitate the extension of classical (non-quantum-like image processing applications to the quantum computing domain. The representation encodes a quantum image in the form of a normalized state, which captures information about colors and their corresponding positions in the images. Since its conception, a handful of processing transformations have been formulated, among which are the geometric transformations on quantum images (GTQI and the CTQI that are focused on the color information of the images. In addition, extensions and applications of FRQI representation, such as multi-channel representation for quantum images (MCQI, quantum image data searching, watermarking strategies for quantum images, a framework to produce movies on quantum computers and a blueprint for quantum video encryption and decryption have also been suggested. These proposals extend classical-like image and video processing applications to the quantum computing domain and offer a significant speed-up with low computational resources in comparison to performing the same tasks on traditional computing devices. Each of the algorithms and the mathematical foundations for their execution were simulated using classical computing resources, and their results were analyzed alongside other classical computing equivalents. The work presented in this review is intended to serve as the epitome of advances made in FRQI quantum image processing over the past five years and to simulate further interest geared towards the realization of some secure and efficient image and video processing applications on quantum computers.

  20. Bit-level quantum color image encryption scheme with quantum cross-exchange operation and hyper-chaotic system

    Science.gov (United States)

    Zhou, Nanrun; Chen, Weiwei; Yan, Xinyu; Wang, Yunqian

    2018-06-01

    In order to obtain higher encryption efficiency, a bit-level quantum color image encryption scheme by exploiting quantum cross-exchange operation and a 5D hyper-chaotic system is designed. Additionally, to enhance the scrambling effect, the quantum channel swapping operation is employed to swap the gray values of corresponding pixels. The proposed color image encryption algorithm has larger key space and higher security since the 5D hyper-chaotic system has more complex dynamic behavior, better randomness and unpredictability than those based on low-dimensional hyper-chaotic systems. Simulations and theoretical analyses demonstrate that the presented bit-level quantum color image encryption scheme outperforms its classical counterparts in efficiency and security.

  1. The Hyperspectral Imager for the Coastal Ocean (HICO): Four Years Operating on the International Space Station (Invited)

    Science.gov (United States)

    Davis, C. O.; Nahorniak, J.; Tufillaro, N.; Kappus, M.

    2013-12-01

    The Hyperspectral Imager for the Coastal Ocean (HICO) is the first spaceborne imaging spectrometer designed to sample the coastal ocean. HICO images selected coastal regions at 92 m spatial resolution with full spectral coverage (88 channels covering 400 to 900 nm) and a high signal-to-noise ratio to resolve the complexity of the coastal ocean. Under sponsorship of the Office of Naval Research, HICO was built by the Naval Research Laboratory, which continues to operate the sensor. HICO has been operating on the International Space Station since October 2009 and has collected over 8000 scenes for more than 50 users. As Project Scientist I have been the link to the international ocean optics community primarily through our OSU HICO website (http://hico.oregonstate.edu). HICO operations are now under NASA support and HICO data is now also be available through the NASA Ocean Color Website (http://oceancolor.gsfc.nasa.gov ). Here we give a brief overview of HICO data and operations and discuss the unique challenges and opportunities that come from operating on the International Space Station.

  2. Operational Automatic Remote Sensing Image Understanding Systems: Beyond Geographic Object-Based and Object-Oriented Image Analysis (GEOBIA/GEOOIA. Part 1: Introduction

    Directory of Open Access Journals (Sweden)

    Andrea Baraldi

    2012-09-01

    Full Text Available According to existing literature and despite their commercial success, state-of-the-art two-stage non-iterative geographic object-based image analysis (GEOBIA systems and three-stage iterative geographic object-oriented image analysis (GEOOIA systems, where GEOOIA/GEOBIA, remain affected by a lack of productivity, general consensus and research. To outperform the degree of automation, accuracy, efficiency, robustness, scalability and timeliness of existing GEOBIA/GEOOIA systems in compliance with the Quality Assurance Framework for Earth Observation (QA4EO guidelines, this methodological work is split into two parts. The present first paper provides a multi-disciplinary Strengths, Weaknesses, Opportunities and Threats (SWOT analysis of the GEOBIA/GEOOIA approaches that augments similar analyses proposed in recent years. In line with constraints stemming from human vision, this SWOT analysis promotes a shift of learning paradigm in the pre-attentive vision first stage of a remote sensing (RS image understanding system (RS-IUS, from sub-symbolic statistical model-based (inductive image segmentation to symbolic physical model-based (deductive image preliminary classification. Hence, a symbolic deductive pre-attentive vision first stage accomplishes image sub-symbolic segmentation and image symbolic pre-classification simultaneously. In the second part of this work a novel hybrid (combined deductive and inductive RS-IUS architecture featuring a symbolic deductive pre-attentive vision first stage is proposed and discussed in terms of: (a computational theory (system design; (b information/knowledge representation; (c algorithm design; and (d implementation. As proof-of-concept of symbolic physical model-based pre-attentive vision first stage, the spectral knowledge-based, operational, near real-time Satellite Image Automatic Mapper™ (SIAM™ is selected from existing literature. To the best of these authors’ knowledge, this is the first time a

  3. Intra-operative ultrasound hand-held strain imaging for the visualization of ablations produced in the liver with a toroidal HIFU transducer: first in vivo results

    Energy Technology Data Exchange (ETDEWEB)

    Chenot, J; Melodelima, D; N' Djin, W A; Souchon, Remi; Rivoire, M; Chapelon, J Y, E-mail: jeremy.chenot@inserm.f [Inserm, U556, Lyon, F-69003 (France)

    2010-06-07

    The use of hand-held ultrasound strain imaging for the intra-operative real-time visualization of HIFU (high-intensity focused ultrasound) ablations produced in the liver by a toroidal transducer was investigated. A linear 12 MHz ultrasound imaging probe was used to obtain radiofrequency signals. Using a fast cross-correlation algorithm, strain images were calculated and displayed at 60 frames s{sup -1}, allowing the use of hand-held strain imaging intra-operatively. Fourteen HIFU lesions were produced in four pigs. Intra-operative strain imaging of HIFU ablations in the liver was feasible owing to the high frame rate. The correlation between dimensions measured on gross pathology and dimensions measured on B-mode images and on strain images were R = 0.72 and R = 0.94 respectively. The contrast between ablated and non-ablated tissue was significantly higher (p < 0.05) in the strain images (22 dB) than in the B-mode images (9 dB). Strain images allowed equivalent or improved definition of ablated regions when compared with B-mode images. Real-time intra-operative hand-held strain imaging seems to be a promising complement to conventional B-mode imaging for the guidance of HIFU ablations produced in the liver during an open procedure. These results support that hand-held strain imaging outperforms conventional B-mode ultrasound and could potentially be used for the assessment of thermal therapies.

  4. Pathologic and post-operative conditions of the plantar fascia: review of MR imaging appearances

    Energy Technology Data Exchange (ETDEWEB)

    Yu, J.S. [Ohio State Univ., Columbus (United States). Dept. of Radiology

    2000-09-01

    Magnetic resonance (MR) imaging has emerged as an important noninvasive diagnostic imaging technique for assessment of foot pathology. This modality, owing to its multiplanar imaging capability and inherent superiority in contrast, has been shown to be more accurate and sensitive for detection of plantar fascia pathology than any other imaging method. One of the most important and recognizable causes of heel pain is plantar fasciitis. With the exception of plantar fasciitis, there has been little emphasis on imaging other conditions that affect this important structure. The objective of this review is to demonstrate, from a perspective of MR imaging, the many different pathologic conditions that affect the plantar fascia. Included in this review will be a discussion of normal anatomy as well as entities such as acute plantar fasciitis, chronic plantar fasciitis, traumatic rupture, normal post-surgical changes, pathologic post-fasciotomy conditions, infection, and fibromatosis. (orig.)

  5. Pathologic and post-operative conditions of the plantar fascia: review of MR imaging appearances

    International Nuclear Information System (INIS)

    Yu, J.S.

    2000-01-01

    Magnetic resonance (MR) imaging has emerged as an important noninvasive diagnostic imaging technique for assessment of foot pathology. This modality, owing to its multiplanar imaging capability and inherent superiority in contrast, has been shown to be more accurate and sensitive for detection of plantar fascia pathology than any other imaging method. One of the most important and recognizable causes of heel pain is plantar fasciitis. With the exception of plantar fasciitis, there has been little emphasis on imaging other conditions that affect this important structure. The objective of this review is to demonstrate, from a perspective of MR imaging, the many different pathologic conditions that affect the plantar fascia. Included in this review will be a discussion of normal anatomy as well as entities such as acute plantar fasciitis, chronic plantar fasciitis, traumatic rupture, normal post-surgical changes, pathologic post-fasciotomy conditions, infection, and fibromatosis. (orig.)

  6. Endoscopic third ventriculocisternostomies in the infant: Pre- and post-operative Magnetic resonance imaging evaluation elective project undergraduate prize 2000

    Energy Technology Data Exchange (ETDEWEB)

    Sharman, Anna

    2000-12-01

    PURPOSE: To determine whether it is possible to select patients with obstructive hydrocephalus, in the under 1 age group for endoscopic third ventriculocisternostomy (ETV) using pre-operative T2 weighted turbo spin echo (T2W-TSE) sagittal sequence Magnetic Resonance (MR) imaging; and to assess ventriculocisternostomy patency using post-operative T2W-TSE MR. PATIENTS AND METHODS: A retrospective review of MR examinations and clinical notes of 11 patients under 1 year of age who had ETV, was performed. The post-operative flow MR images were divided into the presence or absence of flow-related signal changes. RESULTS: In 6 of the 11 patients, ETV was successful (54.5%) i.e. no VP shunt or revision of the ETV was required. 9 patients had post-operative T2W-TSE MR examinations -- 8 of these 9 MR studies correlated to the clinical situation (89%). The remaining MR examination showed a CSF flow void but the ETV failed at 3 weeks. CONCLUSION: Pre-operative MR using T2W-TSE to select suitable candidates for ETV improves the success rate from < 40% to 54.5%. Post-operatively MRI is a good predictor of whether the ETV has been successful or not. Sharman, A. (2000)

  7. Large-Scale Multi-Resolution Representations for Accurate Interactive Image and Volume Operations

    KAUST Repository

    Sicat, Ronell Barrera

    2015-01-01

    approach is to employ output-sensitive operations on multi-resolution data representations. Output-sensitive operations facilitate interactive applications since their required computations are proportional only to the size of the data that is visible, i

  8. An investigation of the performance of a coaxial HPGe detector operating in a magnetic resonance imaging field

    Energy Technology Data Exchange (ETDEWEB)

    Harkness, L.J., E-mail: ljh@ns.ph.liv.ac.u [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Boston, A.J.; Boston, H.C.; Cole, P.; Cresswell, J.R.; Filmer, F.; Jones, M.; Judson, D.S.; Nolan, P.J.; Oxley, D.C.; Sampson, J.A.; Scraggs, D.P.; Slee, M.J. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Bimson, W.E.; Kemp, G.J. [MARIARC, University of Liverpool, Liverpool L69 3GE (United Kingdom); Groves, J.; Headspith, J.; Lazarus, I.; Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Cooper, R.J. [Joint Institute for Heavy Ion Research, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6371 (United States)

    2011-05-11

    Nuclear medical imaging modalities such as positron emission tomography and single photon emission computed tomography are used to probe physiological functions of the body by detecting gamma rays emitted from biologically targeted radiopharmaceuticals. A system which is capable of simultaneous data acquisition for nuclear medical imaging and magnetic resonance imaging is highly sought after by the medical imaging community. Such a device could provide a more complete medical insight into the functions of the body within a well-defined structural context. However, acquiring simultaneous nuclear/MRI sequences are technically challenging due to the conventional photomultiplier tube readout employed by most existing scintillator detector systems. A promising solution is a nuclear imaging device composed of semiconductor detectors that can be operated with a standard MRI scanner. However, the influence of placing a semiconductor detector such as high purity germanium (HPGe) within or close to the bore of an MRI scanner, where high magnetic fields are present, is not well understood. In this paper, the performance of a HPGe detector operating in a high strength static (B{sub S}) MRI field along with fast switching gradient fields and radiofrequency from the MRI system has been assessed. The influence of the B{sub S} field on the energy resolution of the detector has been investigated for various positions and orientations of the detector within the magnetic field. The results have then been interpreted in terms of the influence of the B{sub S} field on the charge collection properties. MRI images have been acquired with the detector situated at the entrance of the MRI bore to investigate the effects of simultaneous data acquisition on detector performance and MRI imaging.

  9. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 4. Medical Imaging Procedures.

    Science.gov (United States)

    Byrum, Russell; Keith, Lauren; Bartos, Christopher; St Claire, Marisa; Lackemeyer, Matthew G; Holbrook, Michael R; Janosko, Krisztina; Barr, Jason; Pusl, Daniela; Bollinger, Laura; Wada, Jiro; Coe, Linda; Hensley, Lisa E; Jahrling, Peter B; Kuhn, Jens H; Lentz, Margaret R

    2016-10-03

    Medical imaging using animal models for human diseases has been utilized for decades; however, until recently, medical imaging of diseases induced by high-consequence pathogens has not been possible. In 2014, the National Institutes of Health, National Institute of Allergy and Infectious Diseases, Integrated Research Facility at Fort Detrick opened an Animal Biosafety Level 4 (ABSL-4) facility to assess the clinical course and pathology of infectious diseases in experimentally infected animals. Multiple imaging modalities including computed tomography (CT), magnetic resonance imaging, positron emission tomography, and single photon emission computed tomography are available to researchers for these evaluations. The focus of this article is to describe the workflow for safely obtaining a CT image of a live guinea pig in an ABSL-4 facility. These procedures include animal handling, anesthesia, and preparing and monitoring the animal until recovery from sedation. We will also discuss preparing the imaging equipment, performing quality checks, communication methods from "hot side" (containing pathogens) to "cold side," and moving the animal from the holding room to the imaging suite.

  10. Framework for a low-cost intra-operative image-guided neuronavigator including brain shift compensation.

    Science.gov (United States)

    Bucki, M; Lobos, C; Payan, Y

    2007-01-01

    In this paper we present a methodology to address the problem of brain tissue deformation referred to as 'brain-shift'. This deformation occurs throughout a neurosurgery intervention and strongly alters the accuracy of the neuronavigation systems used to date in clinical routine which rely solely on pre-operative patient imaging to locate the surgical target, such as a tumour or a functional area. After a general description of the framework of our intra-operative image-guided system, we describe a procedure to generate patient specific finite element meshes of the brain and propose a biomechanical model which can take into account tissue deformations and surgical procedures that modify the brain structure, like tumour or tissue resection.

  11. A low-cost vector processor boosting compute-intensive image processing operations

    Science.gov (United States)

    Adorf, Hans-Martin

    1992-01-01

    Low-cost vector processing (VP) is within reach of everyone seriously engaged in scientific computing. The advent of affordable add-on VP-boards for standard workstations complemented by mathematical/statistical libraries is beginning to impact compute-intensive tasks such as image processing. A case in point in the restoration of distorted images from the Hubble Space Telescope. A low-cost implementation is presented of the standard Tarasko-Richardson-Lucy restoration algorithm on an Intel i860-based VP-board which is seamlessly interfaced to a commercial, interactive image processing system. First experience is reported (including some benchmarks for standalone FFT's) and some conclusions are drawn.

  12. Assessment of maxillary sinus volume for the sinus lift operation by three-dimensional magnetic resonance imaging.

    Science.gov (United States)

    Gray, C F; Staff, R T; Redpath, T W; Needham, G; Renny, N M

    2000-05-01

    To calculate sinus and bone graft volumes and vertical bone heights from sequential magnetic resonance imaging (MRI) examinations in patients undergoing a sinus lift operation. MRI scans were obtained pre-operatively and at 10 days and 10 weeks post-operatively, using a 0.95 tesla MRI scanner and a three-dimensional (3D) magnetisation prepared, rapid acquisition gradient-echo (MP-RAGE) sequence. Estimates of the bone graft volumes required for a desired vertical bone height were made from the pre-operative MRI scan. Measurements of the graft volumes and bone heights actually achieved were made from the post-operative scans. The MRI appearance of the graft changed between the 10 day and 10 week scans. We have proposed a technique which has the potential to give the surgeon an estimate of the optimum volume of graft for the sinus lift operation from the pre-operative MRI scan alone and demonstrated its application in a single patient. Changes in the sequential MRI appearance of the graft are consistent with replacement of fluid by a matrix of trabecular bone.

  13. Concrete Image Segmentation Based on Multiscale Mathematic Morphology Operators and Otsu Method

    Directory of Open Access Journals (Sweden)

    Sheng-Bo Zhou

    2015-01-01

    Full Text Available The aim of the current study lies in the development of a reformative technique of image segmentation for Computed Tomography (CT concrete images with the strength grades of C30 and C40. The results, through the comparison of the traditional threshold algorithms, indicate that three threshold algorithms and five edge detectors fail to meet the demand of segmentation for Computed Tomography concrete images. The paper proposes a new segmentation method, by combining multiscale noise suppression morphology edge detector with Otsu method, which is more appropriate for the segmentation of Computed Tomography concrete images with low contrast. This method cannot only locate the boundaries between objects and background with high accuracy, but also obtain a complete edge and eliminate noise.

  14. High-intensity power-resolved radiation imaging of an operational nuclear reactor

    OpenAIRE

    Beaumont, Jonathan; Villa, Mario; Mellor, Matthew; Joyce, Malcolm John

    2015-01-01

    Knowledge of the neutron distribution in a nuclear reactor is necessary to ensure the safe and efficient burnup of reactor fuel. Currently these measurements are performed by in-core systems in what are extremely hostile environments and in most reactor accident scenarios it is likely that these systems would be damaged. Here we present a compact and portable radiation imaging system with the ability to image high-intensity fast-neutron and gamma-ray fields simultaneously. This system has bee...

  15. Post-operative orbital imaging: a focus on implants and prosthetic devices

    International Nuclear Information System (INIS)

    Adams, Ashok; Mankad, Kshitij; Poitelea, Cornelia; Verity, David H.; Davagnanam, Indran

    2014-01-01

    Accurate interpretation of orbital imaging in the presence of either orbital implants requires a sound knowledge of both the surgical approach used and the imaging characteristics of the implanted devices themselves. In this article, the radiological appearance of the various devices used in ophthalmology, and their relationship to other orbital structures, is reviewed. In addition, the intended anatomical location, function of these devices, and clinical indications for their use are provided. (orig.)

  16. Connected Operators : A review of region-based morphological image processing techniques

    NARCIS (Netherlands)

    Salembier, Philippe; Wilkinson, Michael H. F.

    2009-01-01

    Connected operators are filtering tools that act by merging elementary regions called flat zones. Connecting operators cannot create new contours nor modify their position. Therefore, they have very good contour preservation properties and are capable of both low-level filtering and higher-level

  17. Connected Operators : A review of region-based morphological image processing techniques

    NARCIS (Netherlands)

    Salembier, Philippe; Wilkinson, Michael H. F.

    Connected operators are filtering tools that act by merging elementary regions called flat zones. Connecting operators cannot create new contours nor modify their position. Therefore, they have very good contour preservation properties and are capable of both low-level filtering and higher-level

  18. Operational calibration and validation of landsat data continuity mission (LDCM) sensors using the image assessment system (IAS)

    Science.gov (United States)

    Micijevic, Esad; Morfitt, Ron

    2010-01-01

    Systematic characterization and calibration of the Landsat sensors and the assessment of image data quality are performed using the Image Assessment System (IAS). The IAS was first introduced as an element of the Landsat 7 (L7) Enhanced Thematic Mapper Plus (ETM+) ground segment and recently extended to Landsat 4 (L4) and 5 (L5) Thematic Mappers (TM) and Multispectral Sensors (MSS) on-board the Landsat 1-5 satellites. In preparation for the Landsat Data Continuity Mission (LDCM), the IAS was developed for the Earth Observer 1 (EO-1) Advanced Land Imager (ALI) with a capability to assess pushbroom sensors. This paper describes the LDCM version of the IAS and how it relates to unique calibration and validation attributes of its on-board imaging sensors. The LDCM IAS system will have to handle a significantly larger number of detectors and the associated database than the previous IAS versions. An additional challenge is that the LDCM IAS must handle data from two sensors, as the LDCM products will combine the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) spectral bands.

  19. Evaluation of ventricular function of patients with tetralogy of Fallot before and after operation by radionuclide myocardial imaging

    International Nuclear Information System (INIS)

    Zhang Nanbin; Wang Zengwei; Zhang Renfu; Chen Xianying; Liu Zhifan; Zhang Zhaozhong; Wang Kaigen

    1996-01-01

    Radionuclide myocardial imaging was utilized to evaluate the ventricular function of 43 patients with tetralogy of Fallot in preoperative and postoperative periods. The examination was made before and 25∼35 days after operation respectively. Ventricular ejection fraction, peak ejection rate and peak filling rate were used as indices for cardiac function. Before operation, the average left ventricular ejection fraction (LVEF) was 55%, the average left ventricular peak ejection rate (LVPER) was 2.95EDV/s and the average left ventricular peak filling rate (LVPFR) was 3.05EDV/s. After operation, the above three values were increased to 71%, 4.35EDV/s and 5.05EDV/s respectively, all with P<0.01. The function of right ventricle before operation was decreased and was significantly improved after operation (RVEF 42% vs 50%, RVPER 2.35EDV/s vs 3.00EDV/s and RVPFR 2.32EDV/s vs 3.36EDV/s, P<0.01). Poor right ventricular function in patients with tetralogy of Fallot is improved after surgical operation. Evaluation of the right ventricular function status is useful for assessing the degree of obstruction of right ventricular outflow tract

  20. Spectral imaging applications: Remote sensing, environmental monitoring, medicine, military operations, factory automation and manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Gat, N.; Subramanian, S. [Opto-Knowledge Systems, Inc. (United States); Barhen, J. [Oak Ridge National Lab., TN (United States); Toomarian, N. [Jet Propulsion Lab., Pasadena, CA (United States)

    1996-12-31

    This paper reviews the activities at OKSI related to imaging spectroscopy presenting current and future applications of the technology. The authors discuss the development of several systems including hardware, signal processing, data classification algorithms and benchmarking techniques to determine algorithm performance. Signal processing for each application is tailored by incorporating the phenomenology appropriate to the process, into the algorithms. Pixel signatures are classified using techniques such as principal component analyses, generalized eigenvalue analysis and novel very fast neural network methods. The major hyperspectral imaging systems developed at OKSI include the Intelligent Missile Seeker (IMS) demonstration project for real-time target/decoy discrimination, and the Thermal InfraRed Imaging Spectrometer (TIRIS) for detection and tracking of toxic plumes and gases. In addition, systems for applications in medical photodiagnosis, manufacturing technology, and for crop monitoring are also under development.

  1. Inter-operator Variability in Defining Uterine Position Using Three-dimensional Ultrasound Imaging

    DEFF Research Database (Denmark)

    Baker, Mariwan; Jensen, Jørgen Arendt; Behrens, Claus F.

    2013-01-01

    significantly larger inter-fractional uterine positional displacement, in some cases up to 20 mm, which outweighs the magnitude of current inter-operator variations. Thus, the current US-phantom-study suggests that the inter-operator variability in addressing uterine position is clinically irrelevant.......In radiotherapy the treatment outcome of gynecological (GYN) cancer patients is crucially related to reproducibility of the actual uterine position. The purpose of this study is to evaluate the inter-operator variability in addressing uterine position using a novel 3-D ultrasound (US) system....... The study is initiated by US-scanning of a uterine phantom (CIRS 404, Universal Medical, Norwood, USA) by seven experienced US operators. The phantom represents a female pelvic region, containing a uterus, bladder and rectal landmarks readily definable in the acquired US-scans. The organs are subjected...

  2. A novel algorithm for image representation using discrete spectrum of the Schrödinger operator

    KAUST Repository

    Kaisserli, Zineb; Laleg-Kirati, Taous-Meriem; Lahmar-Benbernou, Amina

    2015-01-01

    This paper extends the recent signal analysis method based on the spectral analysis of the semi-classical Schrödinger operator to two dimensions. An algorithm based on the tensor product approach when writing the eigenfunctions of the semi-classical Schrödinger operator is proposed. The algorithm is described and the effect of some parameters on the convergence of this method are numerically studied. The performance of the algorithm is illustrated through some examples.

  3. A novel algorithm for image representation using discrete spectrum of the Schrödinger operator

    KAUST Repository

    Kaisserli, Zineb

    2015-05-01

    This paper extends the recent signal analysis method based on the spectral analysis of the semi-classical Schrödinger operator to two dimensions. An algorithm based on the tensor product approach when writing the eigenfunctions of the semi-classical Schrödinger operator is proposed. The algorithm is described and the effect of some parameters on the convergence of this method are numerically studied. The performance of the algorithm is illustrated through some examples.

  4. Development of Neuromorphic Sift Operator with Application to High Speed Image Matching

    Science.gov (United States)

    Shankayi, M.; Saadatseresht, M.; Bitetto, M. A. V.

    2015-12-01

    There was always a speed/accuracy challenge in photogrammetric mapping process, including feature detection and matching. Most of the researches have improved algorithm's speed with simplifications or software modifications which increase the accuracy of the image matching process. This research tries to improve speed without enhancing the accuracy of the same algorithm using Neuromorphic techniques. In this research we have developed a general design of a Neuromorphic ASIC to handle algorithms such as SIFT. We also have investigated neural assignment in each step of the SIFT algorithm. With a rough estimation based on delay of the used elements including MAC and comparator, we have estimated the resulting chip's performance for 3 scenarios, Full HD movie (Videogrammetry), 24 MP (UAV photogrammetry), and 88 MP image sequence. Our estimations led to approximate 3000 fps for Full HD movie, 250 fps for 24 MP image sequence and 68 fps for 88MP Ultracam image sequence which can be a huge improvement for current photogrammetric processing systems. We also estimated the power consumption of less than10 watts which is not comparable to current workflows.

  5. Notes on LCW Activation Calculation for Neutron Imaging Operations in the North Cave of Building 194

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, S. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-20

    This note estimates the amount of activation that could be produced in the Facilities-provided Low Conductivity Water (LCW) that is proposed to be used for cooling of electromagnets and beam stops in the Neutron Imaging (NI) accelerator project in the North Cave of Building 194.

  6. Comparing the utility of image algebra operations for characterizing landscape changes: the case of the Mediterranean coast.

    Science.gov (United States)

    Alphan, Hakan

    2011-11-01

    The aim of this study is to compare various image algebra procedures for their efficiency in locating and identifying different types of landscape changes on the margin of a Mediterranean coastal plain, Cukurova, Turkey. Image differencing and ratioing were applied to the reflective bands of Landsat TM datasets acquired in 1984 and 2006. Normalized Difference Vegetation index (NDVI) and Principal Component Analysis (PCA) differencing were also applied. The resulting images were tested for their capacity to detect nine change phenomena, which were a priori defined in a three-level classification scheme. These change phenomena included agricultural encroachment, sand dune afforestation, coastline changes and removal/expansion of reed beds. The percentage overall accuracies of different algebra products for each phenomenon were calculated and compared. The results showed that some of the changes such as sand dune afforestation and reed bed expansion were detected with accuracies varying between 85 and 97% by the majority of the algebra operations, while some other changes such as logging could only be detected by mid-infrared (MIR) ratioing. For optimizing change detection in similar coastal landscapes, underlying causes of these changes were discussed and the guidelines for selecting band and algebra operations were provided. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Comparison of preoperative computerized tomography scan imaging of temporal bone with the intra-operative findings in patients undergoing mastiodectomy

    International Nuclear Information System (INIS)

    Gerami, H.; Naghavi, E.; Wahabi-Moghadam, M.; Forghanparast, K.; Akbar, Manzar H.

    2009-01-01

    Objective was to compare the consistency rates of pre- and intra-operative radiological findings in patients with chronic suppurative otitis media (CSOM). In a cross-sectional study, 80 patients with CSOM underwent pre-operative CT scanning and we compared the results with intra-operative clinical findings during mastiodectomy from 2000-2004 in the Otology Department, Amiralmomenin Hospital of Guilan Medical University, Rasht, Iran. Sensitivity, specificity, positive and negative predictive value of CT scan in tympanic and mastoid cholesteatoma, ossicular chain erosion, tegmentympani erosion, dehiscence of facial canal, lateral semicircular canal (LSCC) fistula were assessed. Then, correlation between radiological findings and intra-operative findings were calculated. The mean age of patients was 27.9+-16.3 years. Mostly were males (n=57 [71.3%]). Correlation of preoperative radiological images with intra-operative clinical findings were moderate to good on tympanic cholesteatoma, mastoid cholesteatoma and ossicular chain erosion, but weak and insignificant in cases of tegmen erosion, facial canal dehiscene and LSCC fistulae. Preoperative CT scan may be helpful in decision-making for surgery in cases of cholesteatoma and ossicular erosion. Despite of limitations radiological scanning is a useful adjunct to management of CSOM. (author)

  8. Efficacy of an Intra-Operative Imaging Software System for Anatomic Anterior Cruciate Ligament Reconstruction Surgery

    Directory of Open Access Journals (Sweden)

    Xudong Zhang

    2012-01-01

    Full Text Available An imaging software system was studied for improving the performance of anatomic anterior cruciate ligament (ACL reconstruction which requires identifying ACL insertion sites for bone tunnel placement. This software predicts and displays the insertion sites based on the literature data and patient-specific bony landmarks. Twenty orthopaedic surgeons performed simulated arthroscopic ACL surgeries on 20 knee specimens, first without and then with the visual guidance by fluoroscopic imaging, and their tunnel entry positions were recorded. The native ACL insertion morphologies of individual specimens were quantified in relation to CT-based bone models and then used to evaluate the software-generated insertion locations. Results suggested that the system was effective in leading surgeons to predetermined locations while the application of averaged insertion morphological information in individual surgeries can be susceptible to inaccuracy and uncertainty. Implications on challenges associated with developing engineering solutions to aid in re-creating or recognizing anatomy in surgical care delivery are discussed.

  9. Grafting polyethylenimine with quinoline derivatives for targeted imaging of intracellular Zn{sup 2+} and logic gate operations

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Yi; Shi, Yupeng; Chen, Junying; Wong, Chap-Mo; Zhang, Heng [Key Laboratory of Sensing Technology and Biomedical Instruments (Guangdong Province), School of Engineering, Sun Yat-Sen University, Guangzhou (China); Li, Mei-Jin [Key Laboratory of Analysis and Detection Technology for Food Safety, Ministry of Education and Fujian Province, Department of Chemistry, Fuzhou University, Fuzhou (China); Li, Cheuk-Wing [Institute of Chinese Medical Sciences, University of Macau (China); Yi, Changqing, E-mail: yichq@mail.sysu.edu.cn [Key Laboratory of Sensing Technology and Biomedical Instruments (Guangdong Province), School of Engineering, Sun Yat-Sen University, Guangzhou (China); Research Institute of Sun Yat-Sen University in Shenzhen, Shenzhen (China)

    2016-12-01

    In this study, a highly sensitive and selective fluorescent Zn{sup 2+} probe which exhibited excellent biocompatibility, water solubility, and cell-membrane permeability, was facilely synthesized in a single step by grafting polyethyleneimine (PEI) with quinoline derivatives. The primary amino groups in the branched PEI can increase water solubility and cell permeability of the probe PEIQ, while quinoline derivatives can specifically recognize Zn{sup 2+} and reduce the potential cytotoxicity of PEI. Basing on fluorescence off-on mechanism, PEIQ demonstrated excellent sensing capability towards Zn{sup 2+} in absolute aqueous solution, where a high sensitivity with a detection limit as low as 38.1 nM, and a high selectivity over competing metal ions and potential interfering amino acids, were achieved. Inspired by these results, elementary logic operations (YES, NOT and INHIBIT) have been constructed by employing PEIQ as the gate while Zn{sup 2+} and EDTA as chemical inputs. Together with the low cytotoxicity and good cell-permeability, the practical application of PEIQ in living cell imaging was satisfactorily demonstrated, emphasizing its wide application in fundamental biology research. - Graphical abstract: The fluorescent Zn{sup 2+} probe, PEIQ, is facilely synthesized by grafting PEI with 8-CAAQ, and demonstrated for the pratical applications in Zn{sup 2+} imaging and implementation of molecular logic operations within biological cells. - Highlights: • PEIQ, fluorescent Zn{sup 2+} probe, is synthesized by grafting PEI with quinoline derivatives. • PEIQ exhibits high sensitivity and selectivity in absolute aqueous solution. • PEIQ is biocompatible, water soluble, and cell-membrane permeable. • Elementary logic operations have been demonstrated for PEIQ/Zn{sup 2+}/EDTA system. • The practical application of PEIQ in living cell imaging is demonstrated.

  10. Cecal volvulus: a rare cause of bowel obstruction in a pediatric patient diagnosed pre-operatively by conventional imaging studies

    International Nuclear Information System (INIS)

    Vo, Nghia J.; O'Hara, Sara M.; Alonso, Maria H.

    2005-01-01

    Cecal volvulus is an acute surgical condition that is extremely rare in children, with a mortality rate of up to 40%. The clinical symptoms are often non-specific, and pediatric patients frequently have neurological deficits with associated communication difficulties, making the clinical diagnosis extremely challenging. Conventional radiographic imaging studies play a key role in the prospective diagnosis in children. We report a rare case of cecal volvulus in a 12-year-old boy who was diagnosed pre-operatively by abdominal radiographs and a contrast enema. (orig.)

  11. Cecal volvulus: a rare cause of bowel obstruction in a pediatric patient diagnosed pre-operatively by conventional imaging studies

    Energy Technology Data Exchange (ETDEWEB)

    Vo, Nghia J.; O' Hara, Sara M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati (United States); Alonso, Maria H. [Cincinnati Children' s Hospital Medical Center, Division of Pediatric and Thoracic Surgery, Cincinnati, Ohio (United States)

    2005-11-01

    Cecal volvulus is an acute surgical condition that is extremely rare in children, with a mortality rate of up to 40%. The clinical symptoms are often non-specific, and pediatric patients frequently have neurological deficits with associated communication difficulties, making the clinical diagnosis extremely challenging. Conventional radiographic imaging studies play a key role in the prospective diagnosis in children. We report a rare case of cecal volvulus in a 12-year-old boy who was diagnosed pre-operatively by abdominal radiographs and a contrast enema. (orig.)

  12. IR-to-visible image upconverter under nonlinear crystal thermal gradient operation.

    Science.gov (United States)

    Maestre, H; Torregrosa, A J; Fernández-Pousa, C R; Capmany, J

    2018-01-22

    In this work we study the enhancement of the field-of-view of an infrared image up-converter by means of a thermal gradient in a PPLN crystal. Our work focuses on compact upconverters, in which both a short PPLN crystal length and high numerical aperture lenses are employed. We found a qualitative increase in both wavelength and angular tolerances, compared to a constant temperature upconverter, which makes it necessary a correct IR wavelength allocation in order to effectively increase the up-converted area.

  13. Bio-Mechanical Model of the Brain for a Per-Operative Image-Guided Neuronavigator Compensating for "Brain-Shift" Deformations

    OpenAIRE

    Bucki, Marek; Lobos, Claudio; Payan, Yohan

    2007-01-01

    International audience; In this paper we present a methodology to address the problem of brain tissue deformation referred to as 'brain-shift'. This deformation occurs throughout a neurosurgery intervention and strongly alters the accuracy of the neuronavigation systems used to date in clinical routine which rely solely on pre-operative patient imaging to locate the surgical target, such as a tumour or a functional area. After a general description of the framework of our intra-operative imag...

  14. Analysis and operation of DePFET X-ray imaging detectors

    International Nuclear Information System (INIS)

    Lauf, Thomas

    2011-01-01

    The latest active pixel sensor for X-ray imaging spectroscopy developed at the Max-Planck-Halbleiterlabor (HLL) is the Depleted P-channel Field Effect Transistor (DePFET). This detector type unites detector and first stage amplification and has excellent energy resolution, low noise readout at high speed and low power consumption. This is combined with the possibility of random accessibility of pixels and on-demand readout. In addition it possesses all advantages of a sidewards depleted device, i.e. 100% fill factor and very good quantum efficiency. In the course of the development of DePFET detectors the need of a data analysis software for DePFET devices became apparent. A new tool was developed within the scope of this thesis, which should enable scientists to analyze DePFET data, but also be flexible enough so it can be adapted to new device variants and analysis challenges. A modular concept was thus implemented: a base program running an analysis by individual steps encapsulating algorithms, which can be interchanged. The result is a flexible, adaptable, and expandable analysis software. The software was used to investigate and qualify different structural variants of DePFET detectors. Algorithms to examine detector effects and methods to correct them were developed and integrated into the software. This way, a standard analysis suite for DePFET data was built up which is used at the HLL. Beside the planned use as detector for the wide field imager in the space X-ray observatory IXO, DePFET matrices will be used as focal plane array on the Mercury Imaging X-ray Spectrometer on board the Mercury probe BepiColombo which is scheduled for launch in 2014. The developed analysis software was used in the detector development for this mission to qualify test structures, analyze detector effects and study experimental results. In the course of this development, detector prototypes were studied in respect of linearity, charge collection and detection efficiency in an

  15. Analysis and operation of DePFET X-ray imaging detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lauf, Thomas

    2011-04-28

    The latest active pixel sensor for X-ray imaging spectroscopy developed at the Max-Planck-Halbleiterlabor (HLL) is the Depleted P-channel Field Effect Transistor (DePFET). This detector type unites detector and first stage amplification and has excellent energy resolution, low noise readout at high speed and low power consumption. This is combined with the possibility of random accessibility of pixels and on-demand readout. In addition it possesses all advantages of a sidewards depleted device, i.e. 100% fill factor and very good quantum efficiency. In the course of the development of DePFET detectors the need of a data analysis software for DePFET devices became apparent. A new tool was developed within the scope of this thesis, which should enable scientists to analyze DePFET data, but also be flexible enough so it can be adapted to new device variants and analysis challenges. A modular concept was thus implemented: a base program running an analysis by individual steps encapsulating algorithms, which can be interchanged. The result is a flexible, adaptable, and expandable analysis software. The software was used to investigate and qualify different structural variants of DePFET detectors. Algorithms to examine detector effects and methods to correct them were developed and integrated into the software. This way, a standard analysis suite for DePFET data was built up which is used at the HLL. Beside the planned use as detector for the wide field imager in the space X-ray observatory IXO, DePFET matrices will be used as focal plane array on the Mercury Imaging X-ray Spectrometer on board the Mercury probe BepiColombo which is scheduled for launch in 2014. The developed analysis software was used in the detector development for this mission to qualify test structures, analyze detector effects and study experimental results. In the course of this development, detector prototypes were studied in respect of linearity, charge collection and detection efficiency in an

  16. Efficient operator splitting algorithm for joint sparsity-regularized SPIRiT-based parallel MR imaging reconstruction.

    Science.gov (United States)

    Duan, Jizhong; Liu, Yu; Jing, Peiguang

    2018-02-01

    Self-consistent parallel imaging (SPIRiT) is an auto-calibrating model for the reconstruction of parallel magnetic resonance imaging, which can be formulated as a regularized SPIRiT problem. The Projection Over Convex Sets (POCS) method was used to solve the formulated regularized SPIRiT problem. However, the quality of the reconstructed image still needs to be improved. Though methods such as NonLinear Conjugate Gradients (NLCG) can achieve higher spatial resolution, these methods always demand very complex computation and converge slowly. In this paper, we propose a new algorithm to solve the formulated Cartesian SPIRiT problem with the JTV and JL1 regularization terms. The proposed algorithm uses the operator splitting (OS) technique to decompose the problem into a gradient problem and a denoising problem with two regularization terms, which is solved by our proposed split Bregman based denoising algorithm, and adopts the Barzilai and Borwein method to update step size. Simulation experiments on two in vivo data sets demonstrate that the proposed algorithm is 1.3 times faster than ADMM for datasets with 8 channels. Especially, our proposal is 2 times faster than ADMM for the dataset with 32 channels. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Automatic segmentation of the left ventricle in a cardiac MR short axis image using blind morphological operation

    Science.gov (United States)

    Irshad, Mehreen; Muhammad, Nazeer; Sharif, Muhammad; Yasmeen, Mussarat

    2018-04-01

    Conventionally, cardiac MR image analysis is done manually. Automatic examination for analyzing images can replace the monotonous tasks of massive amounts of data to analyze the global and regional functions of the cardiac left ventricle (LV). This task is performed using MR images to calculate the analytic cardiac parameter like end-systolic volume, end-diastolic volume, ejection fraction, and myocardial mass, respectively. These analytic parameters depend upon genuine delineation of epicardial, endocardial, papillary muscle, and trabeculations contours. In this paper, we propose an automatic segmentation method using the sum of absolute differences technique to localize the left ventricle. Blind morphological operations are proposed to segment and detect the LV contours of the epicardium and endocardium, automatically. We test the benchmark Sunny Brook dataset for evaluation of the proposed work. Contours of epicardium and endocardium are compared quantitatively to determine contour's accuracy and observe high matching values. Similarity or overlapping of an automatic examination to the given ground truth analysis by an expert are observed with high accuracy as with an index value of 91.30% . The proposed method for automatic segmentation gives better performance relative to existing techniques in terms of accuracy.

  18. Multi-color pyrometry imaging system and method of operating the same

    Science.gov (United States)

    Estevadeordal, Jordi; Nirmalan, Nirm Velumylum; Tralshawala, Nilesh; Bailey, Jeremy Clyde

    2017-03-21

    A multi-color pyrometry imaging system for a high-temperature asset includes at least one viewing port in optical communication with at least one high-temperature component of the high-temperature asset. The system also includes at least one camera device in optical communication with the at least one viewing port. The at least one camera device includes a camera enclosure and at least one camera aperture defined in the camera enclosure, The at least one camera aperture is in optical communication with the at least one viewing port. The at least one camera device also includes a multi-color filtering mechanism coupled to the enclosure. The multi-color filtering mechanism is configured to sequentially transmit photons within a first predetermined wavelength band and transmit photons within a second predetermined wavelength band that is different than the first predetermined wavelength band.

  19. Seismic Imaging, One-Way Wave Equations, Pseudodifferential Operators, Path Integrals, and all that Jazz

    Science.gov (United States)

    Artoun, Ojenie; David-Rus, Diana; Emmett, Matthew; Fishman, Lou; Fital, Sandra; Hogan, Chad; Lim, Jisun; Lushi, Enkeleida; Marinov, Vesselin

    2006-05-01

    In this report we summarize an extension of Fourier analysis for the solution of the wave equation with a non-constant coefficient corresponding to an inhomogeneous medium. The underlying physics of the problem is exploited to link pseudodifferential operators and phase space path integrals to obtain a marching algorithm that incorporates the backward scattering into the evolution of the wave. This allows us to successfully apply single-sweep, one-way marching methods in inherently two-way environments, which was not achieved before through other methods for this problem.

  20. Short term post-operative morphing of sacrocolpopexy mesh measured by magnetic resonance imaging.

    Science.gov (United States)

    Sindhwani, Nikhil; Callewaert, Geertje; Deprest, Thomas; Housmans, Susanne; Van Beckevoort, Dirk; Deprest, Jan

    2018-04-01

    Sacrocolpopexy (SC) involves suspension of the vaginal vault or cervix to the sacrum using a mesh. Following insertion, the meshes have been observed to have undergone dimensional changes. To quantify dimensional changes of meshes following implantation and characterize their morphology in-vivo. 24 patients underwent SC using PolyVinyliDeneFluoride mesh loaded with Fe 3 O 4 particles. Tailored anterior and posterior mesh flaps were sutured to the respective vaginal walls, uniting at the apex. The posterior flap continued to the sacrum and was attached there. Meshes were visualized on magnetic resonance (MR) imaging at 12 [3-12] (median [range]) months postoperatively and 3D models of the mesh were generated. Dynamic MR sequences were acquired during valsalva to record mesh mobility. The area of the vagina effectively supported by the mesh (Effective Support Area (ESA)) was calculated. The 3D models' wall thickness map was analyzed to identify the locations of mesh folding. Intraclass correlation (ICC) was calculated to test the reliability of the methods. To measure the laxity and flatness of the mesh, the curvature and the ellipticity of the sacral flap were calculated. The ESA calculation methodology had ICC = 0.97. A reduction of 75.49 [61.55-78.67] % (median [IQR]) in area, 47.64 [38.07-59.81] % in anterior flap, and of 23.95 [10.96-27.21] % in the posterior flap was measured. The mesh appeared thicker near its attachment at the sacral promontory (n = 19) and near the vaginal apex (n = 22). The laxity of the mesh was 1.13 [1.10-1.16] and 60.55 [49.76-76.25] % of the sacral flap was flat. We could not reliably measure mesh mobility (ICC = 0.16). A methodology for complete 3D characterization of SC meshes using MR images was presented. After implantation, the supported area is much lower than what is prepared prior to implantation. We propose this happened during the surgery itself. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Preliminary reports of pancreas transplantation: assessment of post operative radiologic imaging

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Lee, Moon Gyu; Cho, Kyoung Sik; Bang, Sun Woo; Han, Duk Jong; Auh, Yong Ho

    1994-01-01

    We report seven cases of pancreas transplantation, first performed in Korea, in the context of postsurgical radiologic studies. All patients with insulin-dependent diabetes mellitus received transplants from cadevaric(n=6) or living related donor(n=1). Retrospective analysis of 27 US(including 19 Duplex US), two CT, four MRI, and three scintigraphy for these patients was made with surgico-pathological correlation in five cases. Of the seven patients, three-month graft survival was five and one-year survival was two. One patient died of abdominal abscess following surgery. US gave the valuable information regarding the graft swelling, vascular complication, and perigraft fluid collection. RBC bleeding scan was effective of the presence or absence and location of intestinal bleeding. CT was useful in determining the extent and severity of the pancreatitis. MRI gave a little information about functional status of the grafted pancreas. The choice of appropriate imaging modalities for postsurgical work up in patients who had pancreas transplantation depends on the clinical conditions of the patients and complications suspected. Further prospective studies appear to be necessary to establish the interval and modality choice for early detection of the complication

  2. Low voltage operation of electro-absorption modulator promising for high-definition 3D imaging application using a three step asymmetric coupled quantum well structure

    International Nuclear Information System (INIS)

    Na, Byung Hoon; Ju, Gun Wu; Cho, Yong Chul; Lee, Yong Tak; Choi, Hee Ju; Jeon, Jin Myeong; Lee, Soo Kyung; Park, Yong Hwa; Park, Chang Young

    2015-01-01

    In this paper, we propose a transmission type electro-absorption modulator (EAM) operating at 850 nm having low operating voltage and high absorption change with low insertion loss using a novel three step asymmetric coupled quantum well (3 ACQW) structure which can be used as an optical image shutter for high-definition (HD) three dimensional (3D) imaging. Theoretical calculations show that the exciton red shift of 3 ACQW structure is more than two times larger than that of rectangular quantum well (RQW) structure while maintaining high absorption change. The EAM having coupled cavities with 3 ACQW structure shows a wide spectral bandwidth and high amplitude modulation at a bias voltage of only -8V, which is 41% lower in operating voltage than that of RQW, making the proposed EAM highly attractive as an optical image shutter for HD 3D imaging applications

  3. DeepPIV: Particle image velocimetry measurements using deep-sea, remotely operated vehicles

    Science.gov (United States)

    Katija, Kakani; Sherman, Alana; Graves, Dale; Klimov, Denis; Kecy, Chad; Robison, Bruce

    2015-11-01

    The midwater region of the ocean (below the euphotic zone and above the benthos) is one of the largest ecosystems on our planet, yet remains one of the least explored. Little-known marine organisms that inhabit midwater have developed life strategies that contribute to their evolutionary success, and may inspire engineering solutions for societally relevant challenges. Although significant advances in underwater vehicle technologies have improved access to midwater, small-scale, in situ fluid mechanics measurement methods that seek to quantify the interactions that midwater organisms have with their physical environment are lacking. Here we present DeepPIV, an instrumentation package affixed to remotely operated vehicles that quantifies fluid motions from the surface of the ocean down to 4000 m depths. Utilizing ambient suspended particulate, fluid-structure interactions are evaluated on a range of marine organisms in midwater. Initial science targets include larvaceans, biological equivalents of flapping flexible foils, that create mucus houses to filter food. Little is known about the structure of these mucus houses and the function they play in selectively filtering particles, and these dynamics can serve as particle-mucus models for human health. Using DeepPIV, we reveal the complex structures and flows generated within larvacean mucus houses, and elucidate how these structures function. Funding is gratefully acknowledged from the Packard Foundation.

  4. High-frequency Total Focusing Method (TFM) imaging in strongly attenuating materials with the decomposition of the time reversal operator associated with orthogonal coded excitations

    Science.gov (United States)

    Villaverde, Eduardo Lopez; Robert, Sébastien; Prada, Claire

    2017-02-01

    In the present work, the Total Focusing Method (TFM) is used to image defects in a High Density Polyethylene (HDPE) pipe. The viscoelastic attenuation of this material corrupts the images with a high electronic noise. In order to improve the image quality, the Decomposition of the Time Reversal Operator (DORT) filtering is combined with spatial Walsh-Hadamard coded transmissions before calculating the images. Experiments on a complex HDPE joint demonstrate that this method improves the signal-to-noise ratio by more than 40 dB in comparison with the conventional TFM.

  5. Morphological image processing operators. Reduction of partial volume effects to improve 3D visualization based on CT data

    International Nuclear Information System (INIS)

    Beier, J.; Bittner, R.C.; Hosten, N.; Troeger, J.; Felix, R.

    1998-01-01

    Aim: The quality of segmentation and three-dimensional reconstruction of anatomical structures in tomographic slices is often impaired by disturbances due to partial volume effects (PVE). The potential for artefact reduction by use of the morphological image processing operators (MO) erosion and dilation is investigated. Results: For all patients under review, the artefacts caused by PVE were significantly reduced by erosion (lung: Mean SBR pre =1.67, SBR post =4.83; brain: SBR pre =1.06, SBR post =1.29) even with only a small number of iterations. Region dilation was applied to integrate further structures (e.g. at tumor borders) into a configurable neighbourhood for segmentation and quantitative analysis. Conclusions: The MO represent an efficient approach for the reduction of PVE artefacts in 3D-CT reconstructions and allow optimised visualization of individual objects. (orig./AJ) [de

  6. Meaning production about an absent image: towards Lula’s coercive conduction in the scope of Operation Lava-Jato

    Directory of Open Access Journals (Sweden)

    Janaina Cardoso Brum

    2017-11-01

    Full Text Available In March 2016, the former president Lula was conducted through a coercive way by the Federal Police in order to depose about his involvement in suspect activities related to Operation Lava Jato. The shooting or any other register of this coercive conduction have been forbidden, thus the national media began to work in the verge of this “denied image”. In this paper, we investigate the process of meaning production about this “absent image” through other images and materialities that circulate in the media discourse game regarding the destabilization/ stabilization of evidence about the March fourth current events. Therefore, the concept of lack, excess and strangeness, established by Ernst, were fundamental. We started with the hypothesis that, answering the lack of imagetic register, it was established a profusion of other imagetic, audiovisual and/or verbal discourses.

  7. Investigation of the influence of image reconstruction filter and scan parameters on operation of automatic tube current modulation systems for different CT scanners

    International Nuclear Information System (INIS)

    Sookpeng, Supawitoo; Martin, Colin J.; Gentle, David J.

    2015-01-01

    Variation in the user selected CT scanning parameters under automatic tube current modulation (ATCM) between hospitals has a substantial influence on the radiation doses and image quality for patients. The aim of this study was to investigate the effect of changing image reconstruction filter and scan parameter settings on tube current, dose and image quality for various CT scanners operating under ATCM. The scan parameters varied were pitch factor, rotation time, collimator configuration, kVp, image thickness and image filter convolution (FC) used for reconstruction. The Toshiba scanner varies the tube current to achieve a set target noise. Changes in the FC setting and image thickness for the first reconstruction were the major factors affecting patient dose. A two-step change in FC from smoother to sharper filters doubles the dose, but is counterbalanced by an improvement in spatial resolution. In contrast, Philips and Siemens scanners maintained tube current values similar to those for a reference image and patient, and the tube current only varied slightly for changes in individual CT scan parameters. The selection of a sharp filter increased the image noise, while use of iDose iterative reconstruction reduced the noise. Since the principles used by CT manufacturers for ATCM vary, it is important that parameters which affect patient dose and image quality for each scanner are made clear to operator to aid in optimisation. (authors)

  8. Estimated cumulative radiation dose received by diagnostic imaging during staging and treatment of operable Ewing sarcoma 2005-2012

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, Boel [Haukeland University Hospital, Centre for Nuclear Medicine and PET, Department of Radiology, P.O. Box 1400, Bergen (Norway); Fasmer, Kristine Eldevik [Haukeland University Hospital, Department of Oncology, Medical Physics Section, Bergen (Norway); Boye, Kjetil [Norwegian Radium Hospital, Oslo University Hospital, Department of Oncology, Oslo (Norway); Rosendahl, Karen; Aukland, Stein Magnus [Haukeland University Hospital, Department of Radiology, Paediatric Section, Bergen (Norway); University of Bergen, Department of Clinical Medicine, Bergen (Norway); Trovik, Clement [University of Bergen, Department of Clinical Medicine, Bergen (Norway); Haukeland University Hospital, Department of Surgery, Orthopaedic Section, Bergen (Norway); Biermann, Martin [Haukeland University Hospital, Centre for Nuclear Medicine and PET, Department of Radiology, P.O. Box 1400, Bergen (Norway); University of Bergen, Department of Clinical Medicine, Bergen (Norway)

    2017-01-15

    Patients with Ewing sarcoma are subject to various diagnostic procedures that incur exposure to ionising radiation. To estimate the radiation doses received from all radiologic and nuclear imaging episodes during diagnosis and treatment, and to determine whether {sup 18}F-fluorodeoxyglucose positron emission tomography - computed tomography ({sup 18}F-FDG PET-CT) is a major contributor of radiation. Twenty Ewing sarcoma patients diagnosed in Norway in 2005-2012 met the inclusion criteria (age <30 years, operable disease, uncomplicated chemotherapy and surgery, no metastasis or residual disease within a year of diagnosis). Radiation doses from all imaging during the first year were calculated for each patient. The mean estimated cumulative radiation dose for all patients was 34 mSv (range: 6-70), radiography accounting for 3 mSv (range: 0.2-12), CT for 13 mSv (range: 2-28) and nuclear medicine for 18 mSv (range: 2-47). For the patients examined with PET-CT, the mean estimated cumulative effective dose was 38 mSv, of which PET-CT accounted for 14 mSv (37%). There was large variation in number and type of examinations performed and also in estimated cumulative radiation dose. The mean radiation dose for patients examined with PET-CT was 23% higher than for patients not examined with PET-CT. (orig.)

  9. Estimated cumulative radiation dose received by diagnostic imaging during staging and treatment of operable Ewing sarcoma 2005-2012

    International Nuclear Information System (INIS)

    Johnsen, Boel; Fasmer, Kristine Eldevik; Boye, Kjetil; Rosendahl, Karen; Aukland, Stein Magnus; Trovik, Clement; Biermann, Martin

    2017-01-01

    Patients with Ewing sarcoma are subject to various diagnostic procedures that incur exposure to ionising radiation. To estimate the radiation doses received from all radiologic and nuclear imaging episodes during diagnosis and treatment, and to determine whether 18 F-fluorodeoxyglucose positron emission tomography - computed tomography ( 18 F-FDG PET-CT) is a major contributor of radiation. Twenty Ewing sarcoma patients diagnosed in Norway in 2005-2012 met the inclusion criteria (age <30 years, operable disease, uncomplicated chemotherapy and surgery, no metastasis or residual disease within a year of diagnosis). Radiation doses from all imaging during the first year were calculated for each patient. The mean estimated cumulative radiation dose for all patients was 34 mSv (range: 6-70), radiography accounting for 3 mSv (range: 0.2-12), CT for 13 mSv (range: 2-28) and nuclear medicine for 18 mSv (range: 2-47). For the patients examined with PET-CT, the mean estimated cumulative effective dose was 38 mSv, of which PET-CT accounted for 14 mSv (37%). There was large variation in number and type of examinations performed and also in estimated cumulative radiation dose. The mean radiation dose for patients examined with PET-CT was 23% higher than for patients not examined with PET-CT. (orig.)

  10. Randomized trial for superiority of high field strength intra-operative magnetic resonance imaging guided resection in pituitary surgery.

    Science.gov (United States)

    Tandon, Vivek; Raheja, Amol; Suri, Ashish; Chandra, P Sarat; Kale, Shashank S; Kumar, Rajinder; Garg, Ajay; Kalaivani, Mani; Pandey, Ravindra M; Sharma, Bhawani S

    2017-03-01

    Till date there are no randomized trials to suggest the superiority of intra-operative magnetic resonance imaging (IOMRI) guided trans-sphenoidal pituitary resection over two dimensional fluoroscopic (2D-F) guided resections. We conducted this trial to establish the superiority of IOMRI in pituitary surgery. Primary objective was to compare extent of tumor resection between the two study arms. It was a prospective, randomized, outcome assessor and statistician blinded, two arm (A: IOMRI, n=25 and B: 2D-F, n=25), parallel group clinical trial. 4 patients from IOMRI group cross-over to 2D-F group and were consequently analyzed in latter group, based on modified intent to treat method. A total of 50 patients were enrolled till completion of trial (n=25 in each study arm). Demographic profile and baseline parameters were comparable among the two arms (p>0.05) except for higher number of endoscopic procedures and experienced neurosurgeons (>10years) in arm B (p=0.02, 0.002 respectively). Extent of resection was similar in both study arms (A, 94.9% vs B, 93.6%; p=0.78), despite adjusting for experience of operating surgeon and use of microscope/endoscope for surgical resection. We observed that use of IOMRI helped optimize the extent of resection in 5/20 patients (25%) for pituitary tumor resection in-group A. Present study failed to observe superiorty of IOMRI over conventional 2D-F guided resection in pituitary macroadenoma surgery. By use of this technology, younger surgeons could validate their results intra-operatively and hence could increase EOR without causing any increase in complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. In Vivo Stabilized SB3, an Attractive GRPR Antagonist, for Pre- and Intra-Operative Imaging for Prostate Cancer.

    Science.gov (United States)

    Bakker, Ingrid L; van Tiel, Sandra T; Haeck, Joost; Doeswijk, Gabriela N; de Blois, Erik; Segbers, Marcel; Maina, Theodosia; Nock, Berthold A; de Jong, Marion; Dalm, Simone U

    2018-03-19

    The gastrin-releasing peptide receptor (GRPR), overexpressed on various tumor types, is an attractive target for receptor-mediated imaging and therapy. Another interesting approach would be the use of GRPR radioligands for pre-operative imaging and subsequent radio-guided surgery, with the goal to improve surgical outcome. GRPR radioligands were successfully implemented in clinical studies, especially Sarabesin 3 (SB3) is an appealing GRPR antagonist with high receptor affinity. Gallium-68 labeled SB3 has good in vivo stability, after labeling with Indium-111; however, the molecule shows poor in vivo stability, which negatively impacts tumor-targeting capacity. A novel approach to increase in vivo stability of radiopeptides is by co-administration of the neutral endopeptidase (NEP) inhibitor, phosphoramidon (PA). We studied in vivo stability and biodistribution of [ 111 In]SB3 without/with (-/+) PA in mice. Furthermore, SPECT/MRI on a novel, state-of-the-art platform was performed. GRPR affinity of SB3 was determined on PC295 xenograft sections using [ 125 I]Tyr 4 -bombesin with tracer only or with increasing concentrations of SB3. For in vivo stability, mice were injected with 200/2000 pmol [ 111 In]SB3 -/+ 300 μg PA. Blood was collected and analyzed. Biodistribution and SPECT/MRI studies were performed at 1, 4, and 24 h postinjection (p.i.) of 2.5 MBq/200 pmol or 25 MBq/200 pmol [ 111 In]SB3 -/+ 300 μg PA in PC-3-xenografted mice. SB3 showed high affinity for GRPR (IC 50 3.5 nM). Co-administration of PA resulted in twice higher intact peptide in vivo vs [ 111 In]SB3 alone. Biodistribution studies at 1, 4, and 24 h p.i. show higher tumor uptake values with PA co-administration (19.7 ± 3.5 vs 10.2 ± 1.5, 17.6 ± 5.1 vs 8.3 ± 1.1, 6.5 ± 3.3 vs 3.1 ± 1.9 % ID/g tissue (P < 0.0001)). Tumor imaging with SPECT/MRI clearly improved after co-injection of PA. Co-administration of PA increased in vivo tumor targeting capacity of

  12. A Dual Polarization, Active, Microstrip Antenna for an Orbital Imaging Radar System Operating at L-Band

    Science.gov (United States)

    Kelly, Kenneth C.; Huang, John

    2000-01-01

    A highly successful Earth orbiting synthetic antenna aperture radar (SAR) system, known as the SIR-C mission, was carried into orbit in 1994 on a U.S. Shuttle (Space Transportation System) mission. The radar system was mounted in the cargo bay with no need to fold, or in any other way reduce the size of the antennas for launch. Weight and size were not limited for the L-Band, C-Band, and X-Band radar systems of the SIR-C radar imaging mission; the set of antennas weighed 10,500 kg, the L-Band antenna having the major share of the weight. This paper treats designing an L-Band antenna functionally similar to that used for SIR-C, but at a fraction of the cost and at a weight in the order of 250 kg. Further, the antenna must be folded to fit into the small payload shroud of low cost booster rocket systems. Over 31 square meters of antenna area is required. This low weight, foldable, electronic scanning antenna is for the proposed LightSAR radar system which is to be placed in Earth orbit on a small, dedicated space craft at the lowest possible cost for an efficient L- Band radar imaging system. This LightSAR spacecraft radar is to be continuously available for at least five operational years, and have the ability to map or repeat-map any area on earth within a few days of any request. A microstrip patch array, with microstrip transmission lines heavily employed in the aperture and in the corporate feed network, was chosen as the low cost approach for this active dual-polarization, 80 MHz (6.4%) bandwidth antenna design.

  13. Pre-operative radiotherapy in soft tissue tumors: Assessment of response by static post-contrast MR imaging compared to histopathology

    International Nuclear Information System (INIS)

    Einarsdottir, H.; Wejde, J.; Bauer, H.C.F.

    2000-01-01

    To evaluate if static post-contrast MR imaging was adequate to assess tumor viability after pre-operative radiotherapy in soft tissue sarcoma. Post-contrast MR imaging of 36 soft tissue sarcomas performed 0 - 54 days (median 13 days) after pre-operative radiotherapy, were retrospectively reviewed and compared to post-operative histopathology reports. The contrast enhancement of the tumor was visually graded as minor, moderate or extensive. From the post-operative histopathology reports, three types of tumor response to radiotherapy were defined: Poor, intermediate or good. The size of the tumors before and after radiation was compared. Even if most viable tumors enhanced more than non-viable tumors, there was major overlapping and significant contrast enhancement could be seen in tumors where histopathological examination revealed no viable tumor tissue. Based on histopathology, there were 12 good responders; 8 of these showed minor, 3 moderate and 1 extensive contrast enhancement on MR imaging. Sixteen tumors had an intermediate response; 3 showed minor, 8 moderate and 5 extensive enhancement. Eight tumors had poor response; none showed minor enhancement, 3 moderate and 5 extensive enhancement. Both increase and Decrease in tumor size was seen in lesions with a good therapy response. Static post-contrast MR imaging cannot reliably assess tumor viability after pre-operative radiotherapy in soft tissue sarcoma. In tumors with no viable tumor tissue, moderate and extensive contrast enhancement can be seen

  14. Quantitative Visualization of Salt Concentration Distributions in Lithium-Ion Battery Electrolytes during Battery Operation Using X-ray Phase Imaging.

    Science.gov (United States)

    Takamatsu, Daiko; Yoneyama, Akio; Asari, Yusuke; Hirano, Tatsumi

    2018-02-07

    A fundamental understanding of concentrations of salts in lithium-ion battery electrolytes during battery operation is important for optimal operation and design of lithium-ion batteries. However, there are few techniques that can be used to quantitatively characterize salt concentration distributions in the electrolytes during battery operation. In this paper, we demonstrate that in operando X-ray phase imaging can quantitatively visualize the salt concentration distributions that arise in electrolytes during battery operation. From quantitative evaluation of the concentration distributions at steady states, we obtained the salt diffusivities in electrolytes with different initial salt concentrations. Because of no restriction on samples and high temporal and spatial resolutions, X-ray phase imaging will be a versatile technique for evaluating electrolytes, both aqueous and nonaqueous, of many electrochemical systems.

  15. PAN SHARPENING QUALITY INVESTIGATION OF TURKISH IN-OPERATION REMOTE SENSING SATELLITES: APPLICATIONS WITH RASAT AND GÖKTÜRK-2 IMAGES

    Directory of Open Access Journals (Sweden)

    M. Ozendi

    2016-10-01

    The aim of this study is to investigate pan-sharpening performance of RASAT and GÖKTÜRK-2 images. For this purpose, pan-sharpened images are generated using most popular pan-sharpening methods IHS, Brovey and PCA at first. This procedure is followed by quantitative evaluation of pan-sharpened images using Correlation Coefficient (CC, Root Mean Square Error (RMSE, Relative Average Spectral Error (RASE, Spectral Angle Mapper (SAM and Erreur Relative Globale Adimensionnelle de Synthése (ERGAS metrics. For generation of pan-sharpened images and computation of metrics SharpQ tool is used which is developed with MATLAB computing language. According to metrics, PCA derived pan-sharpened image is the most similar one to multispectral image for RASAT, and Brovey derived pan-sharpened image is the most similar one to multispectral image for GÖKTÜRK-2. Finally, pan-sharpened images are evaluated qualitatively in terms of object availability and completeness for various land covers (such as urban, forest and flat areas by a group of operators who are experienced in remote sensing imagery.

  16. Prototype readout system for a multi Mpixels UV single-photon imaging detector capable of space flight operation

    Science.gov (United States)

    Seljak, A.; Cumming, H. S.; Varner, G.; Vallerga, J.; Raffanti, R.; Virta, V.

    2018-02-01

    Our collaboration works on the development of a large aperture, high resolution, UV single-photon imaging detector, funded through NASA's Strategic Astrophysics Technology (SAT) program. The detector uses a microchannel plate for charge multiplication, and orthogonal cross strip (XS) anodes for charge readout. Our target is to make an advancement in the technology readiness level (TRL), which enables real scale prototypes to be tested for future NASA missions. The baseline detector has an aperture of 50×50 mm and requires 160 low-noise charge-sensitive channels, in order to extrapolate the incoming photon position with a spatial resolution of about 20 μm FWHM. Technologies involving space flight require highly integrated electronic systems operating at very low power. We have designed two ASICs which enable the construction of such readout system. First, a charge sensitive amplifier (CSAv3) ASIC provides an equivalent noise charge (ENC) of around 600 e-, and a baseline gain of 10 mV/fC. The second, a Giga Sample per Second (GSPS) ASIC, called HalfGRAPH, is a 12-bit analog to digital converter. Its architecture is based on waveform sampling capacitor arrays and has about 8 μs of analog storage memory per channel. Both chips encapsulate 16 measurement channels. Using these chips, a small scale prototype readout system has been constructed on a FPGA Mezzanine Board (FMC), equipped with 32 measurement channels for system evaluation. We describe the construction of HalfGRAPH ASIC, detector's readout system concept and obtained results from the prototype system. As part of the space flight qualification, these chips were irradiated with a Cobalt gamma-ray source, to verify functional operation under ionizing radiation exposure.

  17. Pre-operative CT angiography and three-dimensional image post processing for deep inferior epigastric perforator flap breast reconstructive surgery.

    Science.gov (United States)

    Lam, D L; Mitsumori, L M; Neligan, P C; Warren, B H; Shuman, W P; Dubinsky, T J

    2012-12-01

    Autologous breast reconstructive surgery with deep inferior epigastric artery (DIEA) perforator flaps has become the mainstay for breast reconstructive surgery. CT angiography and three-dimensional image post processing can depict the number, size, course and location of the DIEA perforating arteries for the pre-operative selection of the best artery to use for the tissue flap. Knowledge of the location and selection of the optimal perforating artery shortens operative times and decreases patient morbidity.

  18. ROC [Receiver Operating Characteristics] study of maximum likelihood estimator human brain image reconstructions in PET [Positron Emission Tomography] clinical practice

    International Nuclear Information System (INIS)

    Llacer, J.; Veklerov, E.; Nolan, D.; Grafton, S.T.; Mazziotta, J.C.; Hawkins, R.A.; Hoh, C.K.; Hoffman, E.J.

    1990-10-01

    This paper will report on the progress to date in carrying out Receiver Operating Characteristics (ROC) studies comparing Maximum Likelihood Estimator (MLE) and Filtered Backprojection (FBP) reconstructions of normal and abnormal human brain PET data in a clinical setting. A previous statistical study of reconstructions of the Hoffman brain phantom with real data indicated that the pixel-to-pixel standard deviation in feasible MLE images is approximately proportional to the square root of the number of counts in a region, as opposed to a standard deviation which is high and largely independent of the number of counts in FBP. A preliminary ROC study carried out with 10 non-medical observers performing a relatively simple detectability task indicates that, for the majority of observers, lower standard deviation translates itself into a statistically significant detectability advantage in MLE reconstructions. The initial results of ongoing tests with four experienced neurologists/nuclear medicine physicians are presented. Normal cases of 18 F -- fluorodeoxyglucose (FDG) cerebral metabolism studies and abnormal cases in which a variety of lesions have been introduced into normal data sets have been evaluated. We report on the results of reading the reconstructions of 90 data sets, each corresponding to a single brain slice. It has become apparent that the design of the study based on reading single brain slices is too insensitive and we propose a variation based on reading three consecutive slices at a time, rating only the center slice. 9 refs., 2 figs., 1 tab

  19. Development of an Operational System for the Retrieval of Aerosol and Land Surface Properties from the Terra Multi-Angle Imaging SpectroRadiometer

    Science.gov (United States)

    Crean, Kathleen A.

    2003-01-01

    An operational system to retrieve atmospheric aerosol and land surface properties using data from the Multi-angle Imaging SpectroRadiometer (MISR) instrument, currently flying onboard NASA's Terra spacecraft, has been deployed. The system is in full operation, with new data products generated daily and distributed to science users worldwide. This paper describes the evolution of the system, from initial requirements definition and prototyping through design, implementation, testing, operational deployment, checkout and maintenance activities. The current status of the system and future plans for enhancement are described. Major challenges encountered during implementation are detailed.

  20. Development of image-guided operation system having integrated information of the patient for procedure of endoscopic surgery of digestive tracts

    International Nuclear Information System (INIS)

    Hattori, Asaki; Suzuki, Naoki; Tanoue, Kazuo; Ieiri, Satoshi; Konishi, Kozo; Tomikawa, Morimasa; Kenmotsu, Hajime; Hashizume, Makoto

    2010-01-01

    This study reports the development of patient's integrated information-displaying system at image-guided, robotic peroral endoscopic operation of digestive tracts as well as the actual operative field for the operator not to look aside. The peroral endoscope has, at its top, a magnetic position sensor and 2 robotic manipulative forceps at right and left side to navigate the surgery through following 3 windows of superimposing display: the inner peritoneal 3D structure of the real operative field reconstructed from preoperative CT and MR images by volume rendering, presentation of the robot top tip in the structure above and in the preoperative CT or MR image as an ordinary navigation. Furthermore, the robot has a function to measure softness of its grabbing tissue which is displayed in the corresponding right and left superimposing windows, and signs like the real-time blood pressure and heart rate are also given in another window. All of the patient's integrated information-displaying can be handled at will during the operation. Improvement of user interface and of navigation display is further to be conducted. (T.T.)

  1. Imaging

    International Nuclear Information System (INIS)

    Kellum, C.D.; Fisher, L.M.; Tegtmeyer, C.J.

    1987-01-01

    This paper examines the advantages of the use of excretory urography for diagnosis. According to the authors, excretory urography remains the basic radiologic examination of the urinary tract and is the foundation for the evaluation of suspected urologic disease. Despite development of the newer diagnostic modalities such as isotope scanning, ultrasonography, CT, and magnetic resonsance imaging (MRI), excretory urography has maintained a prominent role in ruorradiology. Some indications have been altered and will continue to change with the newer imaging modalities, but the initial evaluation of suspected urinary tract structural abnormalities; hematuria, pyuria, and calculus disease is best performed with excretory urography. The examination is relatively inexpensive and simple to perform, with few contraindictions. Excretory urography, when properly performed, can provide valuable information about the renal parenchyma, pelvicalyceal system, ureters, and urinary bladder

  2. Study, development and clinical evaluation of a per-operative {gamma} imager; Etude, developpement et evaluation clinique d`un imageur {gamma} per-operatoire

    Energy Technology Data Exchange (ETDEWEB)

    Menard, Laurent [Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1999-01-19

    The precise localization and complete surgical ablation of tumors are one of the most important procedures in cancer treatment. In that context, the use, in operating room, of light hand-held detectors associated to radiopharmaceutical compounds for tumor labelling, plays a significant role in assisting surgeons in real-time detection of lesion. The POCI gamma imaging probe (Per-Operative Compact Imager), which is presented here, is precisely dedicated to improve the radio-guided operative cancer surgery efficiency by bringing a new tool discriminating between healthy and pathological tissues. To match the specifications of intra-operative detection, we chose to build our camera around an intensified position sensitive diode which appeared to be particularly suitable to achieve a high resolution small size imager. The optimal geometry of two gamma detection head modules, composed of parallel hole collimators and scintillation crystals, was then investigated by numerical simulations. From these technological solutions, a first prototype of POCI with a 24 mm diameter field of view has been developed. Its characterization has put forward a millimeter spatial resolution and a detection efficiency comparable to that of clinical gamma cameras and in agreement with the numerical predictions. Finally, in collaboration with Gustave Roussy, a first clinical evaluation of the POCI camera has been performed for sentinel ganglion pre-operative localization in patients afflicted by malignant melanomas or breast cancers. The preliminary results have already shown that the performances of POCI are compatible with intraoperative imaging purposes and suggest how this camera can boost the success rate of tumor removal surgeries for other cancerous diseases. (author) 100 refs., 67 figs., 11 tabs.

  3. Operational Automatic Remote Sensing Image Understanding Systems: Beyond Geographic Object-Based and Object-Oriented Image Analysis (GEOBIA/GEOOIA. Part 2: Novel system Architecture, Information/Knowledge Representation, Algorithm Design and Implementation

    Directory of Open Access Journals (Sweden)

    Luigi Boschetti

    2012-09-01

    Full Text Available According to literature and despite their commercial success, state-of-the-art two-stage non-iterative geographic object-based image analysis (GEOBIA systems and three-stage iterative geographic object-oriented image analysis (GEOOIA systems, where GEOOIA/GEOBIA, remain affected by a lack of productivity, general consensus and research. To outperform the Quality Indexes of Operativeness (OQIs of existing GEOBIA/GEOOIA systems in compliance with the Quality Assurance Framework for Earth Observation (QA4EO guidelines, this methodological work is split into two parts. Based on an original multi-disciplinary Strengths, Weaknesses, Opportunities and Threats (SWOT analysis of the GEOBIA/GEOOIA approaches, the first part of this work promotes a shift of learning paradigm in the pre-attentive vision first stage of a remote sensing (RS image understanding system (RS-IUS, from sub-symbolic statistical model-based (inductive image segmentation to symbolic physical model-based (deductive image preliminary classification capable of accomplishing image sub-symbolic segmentation and image symbolic pre-classification simultaneously. In the present second part of this work, a novel hybrid (combined deductive and inductive RS-IUS architecture featuring a symbolic deductive pre-attentive vision first stage is proposed and discussed in terms of: (a computational theory (system design, (b information/knowledge representation, (c algorithm design and (d implementation. As proof-of-concept of symbolic physical model-based pre-attentive vision first stage, the spectral knowledge-based, operational, near real-time, multi-sensor, multi-resolution, application-independent Satellite Image Automatic Mapper™ (SIAM™ is selected from existing literature. To the best of these authors’ knowledge, this is the first time a symbolic syntactic inference system, like SIAM™, is made available to the RS community for operational use in a RS-IUS pre-attentive vision first stage

  4. Computational Fluid Dynamics (CFD) Image of Hyper-X Research Vehicle at Mach 7 with Engine Operating

    Science.gov (United States)

    1997-01-01

    This computational fluid dynamics (CFD) image shows the Hyper-X vehicle at a Mach 7 test condition with the engine operating. The solution includes both internal (scramjet engine) and external flow fields, including the interaction between the engine exhaust and vehicle aerodynamics. The image illustrates surface heat transfer on the vehicle surface (red is highest heating) and flowfield contours at local Mach number. The last contour illustrates the engine exhaust plume shape. This solution approach is one method of predicting the vehicle performance, and the best method for determination of vehicle structural, pressure and thermal design loads. The Hyper-X program is an ambitious series of experimental flights to expand the boundaries of high-speed aeronautics and develop new technologies for space access. When the first of three aircraft flies, it will be the first time a non-rocket engine has powered a vehicle in flight at hypersonic speeds--speeds above Mach 5, equivalent to about one mile per second or approximately 3,600 miles per hour at sea level. Hyper-X, the flight vehicle for which is designated as X-43A, is an experimental flight-research program seeking to demonstrate airframe-integrated, 'air-breathing' engine technologies that promise to increase payload capacity for future vehicles, including hypersonic aircraft (faster than Mach 5) and reusable space launchers. This multiyear program is currently underway at NASA Dryden Flight Research Center, Edwards, California. The Hyper-X schedule calls for its first flight later this year (2000). Hyper-X is a joint program, with Dryden sharing responsibility with NASA's Langley Research Center, Hampton, Virginia. Dryden's primary role is to fly three unpiloted X-43A research vehicles to validate engine technologies and hypersonic design tools as well as the hypersonic test facility at Langley. Langley manages the program and leads the technology development effort. The Hyper-X Program seeks to significantly

  5. Simple visual review of pre- to post-operative renal ultrasound images predicts pyeloplasty success equally as well as geometric measurements: A blinded comparison with a gold standard.

    Science.gov (United States)

    Kern, Adam J M; Schlomer, Bruce J; Timberlake, Matthew D; Peters, Craig A; Hammer, Matthew R; Jacobs, Micah A

    2017-08-01

    MAG3 diuretic renal scan remains the gold standard for determination of improvement in renal drainage following pyeloplasty for ureteropelvic junction obstruction. We hypothesized that (i) a change in geometric measurements between pre-operative and post-operative renal ultrasound (RUS) images and (ii) blinded simple visual review of images both would predict pyeloplasty success. To determine if simple visual review and/or novel geometric measurement of renal ultrasounds can detect pyeloplasty failure. This study was a retrospective, blinded comparison with a gold standard. Included were children aged ≤18 years undergoing pyeloplasty at our institution from 2009 to 2015. For each kidney, representative pre-operative and post-operative RUS images were chosen. Our standard for pyeloplasty success was improved drainage curve on MAG3 and lack of additional surgery. Measurements for collecting system circularity, roundness, and renal parenchymal to collecting system area ratio (RPCSR) were obtained by three raters (Figure), who were blinded to the outcome of the pyeloplasty. Changes in geometric measurements were analyzed as a diagnostic test for MAG3-defined pyeloplasty success using ROC curve analysis. In addition, six reviewers blinded to pyeloplasty success reviewed pre-operative and post-operative images visually for improved hydronephrosis and categorized pyeloplasty as success or failure based on simple visual review of RUS. Fifty-three repaired renal units were identified (50 children). There were five pyeloplasty failures, four of which underwent revision or nephrectomy. While all geometric measurements could discriminate pyeloplasty failure and success, the geometric measurements that discriminated best between pyeloplasty failure and success were change in collecting system roundness and change in RPCSR. Consensus opinion among six blinded reviewers using simple visual review had a sensitivity of 94% and PPV of 100% with respect to identifying pyeloplasty

  6. Operating scheme for the light-emitting diode array of a volumetric display that exhibits multiple full-color dynamic images

    Science.gov (United States)

    Hirayama, Ryuji; Shiraki, Atsushi; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi

    2017-07-01

    We designed and developed a control circuit for a three-dimensional (3-D) light-emitting diode (LED) array to be used in volumetric displays exhibiting full-color dynamic 3-D images. The circuit was implemented on a field-programmable gate array; therefore, pulse-width modulation, which requires high-speed processing, could be operated in real time. We experimentally evaluated the developed system by measuring the luminance of an LED with varying input and confirmed that the system works appropriately. In addition, we demonstrated that the volumetric display exhibits different full-color dynamic two-dimensional images in two orthogonal directions. Each of the exhibited images could be obtained only from the prescribed viewpoint. Such directional characteristics of the system are beneficial for applications, including digital signage, security systems, art, and amusement.

  7. Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis

    International Nuclear Information System (INIS)

    Fintel, D.J.; Links, J.M.; Brinker, J.A.; Frank, T.L.; Parker, M.; Becker, L.C.

    1989-01-01

    Qualitative interpretation of tomographic and planar scintigrams, a five point rating scale and receiver operating characteristic analysis were utilized to compare single photon emission computed tomography and conventional planar imaging of myocardial thallium-201 uptake in the accuracy of the diagnosis of coronary artery disease and individual vessel involvement. One hundred twelve patients undergoing cardiac catheterization and 23 normal volunteers performed symptom-limited treadmill exercise, followed by stress and redistribution imaging by both tomographic and planar techniques, with the order determined randomly. Paired receiver operating characteristic curves revealed that single photon emission computed tomography was more accurate than planar imaging over the entire range of decision thresholds for the overall detection and exclusion of coronary artery disease and involvement of the left anterior descending and left circumflex coronary arteries. Tomography offered relatively greater advantages in male patients and in patients with milder forms of coronary artery disease, who had no prior myocardial infarction, only single vessel involvement or no lesion greater than or equal to 50 to 69%. Tomography did not appear to provide improved diagnosis in women or in detection of disease in the right coronary artery. Although overall detection of coronary artery disease was not improved in patients with prior myocardial infarction, tomography provided improved identification of normal and abnormal vascular regions. These results indicate that single photon emission computed tomography provides improved diagnostic performance compared with planar imaging in many clinical subgroups

  8. Hot Spots Detection of Operating PV Arrays through IR Thermal Image Using Method Based on Curve Fitting of Gray Histogram

    Directory of Open Access Journals (Sweden)

    Jiang Lin

    2016-01-01

    Full Text Available The overall efficiency of PV arrays is affected by hot spots which should be detected and diagnosed by applying responsible monitoring techniques. The method using the IR thermal image to detect hot spots has been studied as a direct, noncontact, nondestructive technique. However, IR thermal images suffer from relatively high stochastic noise and non-uniformity clutter, so the conventional methods of image processing are not effective. The paper proposes a method to detect hotspots based on curve fitting of gray histogram. The result of MATLAB simulation proves the method proposed in the paper is effective to detect the hot spots suppressing the noise generated during the process of image acquisition.

  9. Perbandingan Kapasitas Pesan pada Steganografi DCT Sekuensial dan Steganografi DCT F5 dengan Penerapan Point Operation Image Enhancement

    Directory of Open Access Journals (Sweden)

    Dian Hafidh Zulfikar

    2016-01-01

        Based on test results that have to be got several conclusions that capacity steganographic message on DCT sequential greater than the DCT F5 steganography either before or after application of the application POIE, stego image quality on DCT steganography F5 better than the sequential DCT steganography well before the application POIE and after application of POIE, both F5 and steganography steganography DCT DCT sequential equally resistant to manipulation of stego image.

  10. Congenital anorectal atresia: MR imaging of late post-operative appearances in adult patients with anal incontinence

    International Nuclear Information System (INIS)

    Gartner, Louise; Peiris, Chand; Marshall, Michele; Taylor, Stuart A.; Halligan, Steve

    2013-01-01

    To describe the MR imaging findings in adults presenting with anal incontinence following pull-through perineoplasty for anorectal atresia. 15 adults (12 male, 3 female; age 22-52 years) with anal incontinence following a prior perineal pull-through procedure as an infant for anorectal atresia were identified retrospectively. MR imaging was performed using either an endoanal coil or body coil. MR images were reviewed by three observers who noted whether pelvic floor and sphincter muscles were present and, if so, whether they were thinned or not. Data were tabulated and raw frequencies determined. Images were unavailable for one patient, leaving 14 for analysis. Anal stenosis prevented endoanal coil placement in 5. The pull-through was anatomically correct in 12 (86 %) patients but was misdirected in 2. Thinned muscle was seen in 11 (79 %) patients. External sphincter thinning was commonest (present in 10 patients), with levator plate thinning least common (present in 4 patients). Only one patient had thinning of all muscle groups. MR imaging may be used to determine the extent and quality of residual pelvic floor and anal sphincter muscle in adults who have functional disability following pull-through perineoplasty for anorectal agenesis. (orig.)

  11. Identifying non-toxic doses of manganese for manganese-enhanced magnetic resonance imaging to map brain areas activated by operant behavior in trained rats.

    Science.gov (United States)

    Gálosi, Rita; Szalay, Csaba; Aradi, Mihály; Perlaki, Gábor; Pál, József; Steier, Roy; Lénárd, László; Karádi, Zoltán

    2017-04-01

    Manganese-enhanced magnetic resonance imaging (MEMRI) offers unique advantages such as studying brain activation in freely moving rats, but its usefulness has not been previously evaluated during operant behavior training. Manganese in a form of MnCl 2 , at a dose of 20mg/kg, was intraperitoneally infused. The administration was repeated and separated by 24h to reach the dose of 40mg/kg or 60mg/kg, respectively. Hepatotoxicity of the MnCl 2 was evaluated by determining serum aspartate aminotransferase, alanine aminotransferase, total bilirubin, albumin and protein levels. Neurological examination was also carried out. The animals were tested in visual cue discriminated operant task. Imaging was performed using a 3T clinical MR scanner. T1 values were determined before and after MnCl 2 administrations. Manganese-enhanced images of each animal were subtracted from their baseline images to calculate decrease in the T1 value (ΔT1) voxel by voxel. The subtracted T1 maps of trained animals performing visual cue discriminated operant task, and those of naive rats were compared. The dose of 60mg/kg MnCl 2 showed hepatotoxic effect, but even these animals did not exhibit neurological symptoms. The dose of 20 and 40mg/kg MnCl 2 increased the number of omissions and did not affect the accuracy of performing the visual cue discriminated operant task. Using the accumulated dose of 40mg/kg, voxels with a significant enhanced ΔT1 value were detected in the following brain areas of the visual cue discriminated operant behavior performed animals compared to those in the controls: the visual, somatosensory, motor and premotor cortices, the insula, cingulate, ectorhinal, entorhinal, perirhinal and piriform cortices, hippocampus, amygdala with amygdalohippocampal areas, dorsal striatum, nucleus accumbens core, substantia nigra, and retrorubral field. In conclusion, the MEMRI proved to be a reliable method to accomplish brain activity mapping in correlation with the operant behavior

  12. MR Imaging of Ventriculus Terminalis of The Conus Medullaris. A report of two operated patients and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Dullerud, Reidar; Server, A. [Ullevaal Univ. Hospital, Oslo (Norway). Div. of Radiology; Berg-Johnsen, J. [The National Hospital, Oslo (Norway). Dept. of Neurosurgery

    2003-07-01

    We report on 2 patients in whom a cystic dilation of the conus medullaris was incidentally found at MR imaging carried out in the work-up for sciatica. The cysts were well circumscribed and had signal intensity identical to the CSF on both T1- and T2-weighted images. There was no evidence of contrast enhancement. None of the patients had specific symptoms related to the spinal cord. At surgery, no evidence of malignancy was seen in any of the patients. A benign cystic dilation, also called dilated ventriculus terminalis, occasionally can be seen in the conus medullaris as an incidental finding at thoracolumbar MR imaging. Unless the expansion per se indicates cyst drainage, these patients may be monitored by clinical and MR follow-up, avoiding surgery in a substantial number of cases.

  13. MR Imaging of Ventriculus Terminalis of The Conus Medullaris. A report of two operated patients and review of the literature

    International Nuclear Information System (INIS)

    Dullerud, Reidar; Server, A.; Berg-Johnsen, J.

    2003-01-01

    We report on 2 patients in whom a cystic dilation of the conus medullaris was incidentally found at MR imaging carried out in the work-up for sciatica. The cysts were well circumscribed and had signal intensity identical to the CSF on both T1- and T2-weighted images. There was no evidence of contrast enhancement. None of the patients had specific symptoms related to the spinal cord. At surgery, no evidence of malignancy was seen in any of the patients. A benign cystic dilation, also called dilated ventriculus terminalis, occasionally can be seen in the conus medullaris as an incidental finding at thoracolumbar MR imaging. Unless the expansion per se indicates cyst drainage, these patients may be monitored by clinical and MR follow-up, avoiding surgery in a substantial number of cases

  14. Hand-gesture-based sterile interface for the operating room using contextual cues for the navigation of radiological images.

    Science.gov (United States)

    Jacob, Mithun George; Wachs, Juan Pablo; Packer, Rebecca A

    2013-06-01

    This paper presents a method to improve the navigation and manipulation of radiological images through a sterile hand gesture recognition interface based on attentional contextual cues. Computer vision algorithms were developed to extract intention and attention cues from the surgeon's behavior and combine them with sensory data from a commodity depth camera. The developed interface was tested in a usability experiment to assess the effectiveness of the new interface. An image navigation and manipulation task was performed, and the gesture recognition accuracy, false positives and task completion times were computed to evaluate system performance. Experimental results show that gesture interaction and surgeon behavior analysis can be used to accurately navigate, manipulate and access MRI images, and therefore this modality could replace the use of keyboard and mice-based interfaces.

  15. Preliminary assessment of the imaging capability of the YAP-(S)PET small animal scanner in neuroscience

    Energy Technology Data Exchange (ETDEWEB)

    Bartoli, Antonietta [Department of Physics ' E. Fermi' and Center of Excellence ' AmbiSEN' , University of Pisa, and INFN, Sezione di Pisa, Pisa I- 56127 (Italy)]. E-mail: bartoli@df.unipi.it; Belcari, Nicola [Department of Physics ' E. Fermi' and Center of Excellence ' AmbiSEN' , University of Pisa, and INFN, Sezione di Pisa, Pisa I- 56127 (Italy); Stark, Daniela [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Hoehnemann, Sabine [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Piel, Markus [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Jennewein, Marc [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Schmitt, Ulrich [Department of Psychiatry, University of Mainz, Mainz D-55099 (Germany); Tillmanns, Julia [Institute of Physiology and Pathophysiology, University of Mainz, Mainz D-55099 (Germany); Thews, Oliver [Institute of Physiology and Pathophysiology, University of Mainz, Mainz D-55099 (Germany); Hiemke, Christoph [Department of Psychiatry, University of Mainz, Mainz D-55099 (Germany); Roesch, Frank [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Del Guerra, Alberto [Department of Physics ' E. Fermi' and Center of Excellence ' AmbiSEN' , University of Pisa, and INFN, Sezione di Pisa, Pisa I- 56127 (Italy)

    2006-12-20

    The new and fully engineered version of the YAP-(S)PET small animal scanner has been tested at the University of Mainz for preliminary assessment of its imaging capability for studies related to neuropharmacology and psychiatry. The main feature of the scanner is the capability to combine PET and SPECT techniques. It allows the development of new and interesting protocols for the investigation of many biological phenomena, more effectively than with PET or SPECT modalities alone. The scanner is made up of four detector heads, each one composed of a 4x4 cm{sup 2} of YAlO{sub 3}:Ce (or YAP:Ce) matrix, and has a field of view (FOV) of 4 cm axiallyx4 cm o transaxially. In PET mode, the volume resolution is less than 8 mm{sup 3} and is nearly constant over the whole FOV, while the sensitivity is about 2%. The SPECT performance is not so good, due to the presence of the multi-hole lead collimator in front of each head. Nevertheless, the YAP-PET scanner offers excellent resolution and sensitivity for performing on the availability of D2-like dopamine receptors on mice and rats in both PET and SPECT modalities.

  16. Preliminary assessment of the imaging capability of the YAP-(S)PET small animal scanner in neuroscience

    International Nuclear Information System (INIS)

    Bartoli, Antonietta; Belcari, Nicola; Stark, Daniela; Hoehnemann, Sabine; Piel, Markus; Jennewein, Marc; Schmitt, Ulrich; Tillmanns, Julia; Thews, Oliver; Hiemke, Christoph; Roesch, Frank; Del Guerra, Alberto

    2006-01-01

    The new and fully engineered version of the YAP-(S)PET small animal scanner has been tested at the University of Mainz for preliminary assessment of its imaging capability for studies related to neuropharmacology and psychiatry. The main feature of the scanner is the capability to combine PET and SPECT techniques. It allows the development of new and interesting protocols for the investigation of many biological phenomena, more effectively than with PET or SPECT modalities alone. The scanner is made up of four detector heads, each one composed of a 4x4 cm 2 of YAlO 3 :Ce (or YAP:Ce) matrix, and has a field of view (FOV) of 4 cm axiallyx4 cm o transaxially. In PET mode, the volume resolution is less than 8 mm 3 and is nearly constant over the whole FOV, while the sensitivity is about 2%. The SPECT performance is not so good, due to the presence of the multi-hole lead collimator in front of each head. Nevertheless, the YAP-PET scanner offers excellent resolution and sensitivity for performing on the availability of D2-like dopamine receptors on mice and rats in both PET and SPECT modalities

  17. Optical devices for proximity operations study and test report. [intensifying images for visual observation during space transportation system activities

    Science.gov (United States)

    Smith, R. A.

    1979-01-01

    Operational and physical requirements were investigated for a low-light-level viewing device to be used as a window-mounted optical sight for crew use in the pointing, navigating, stationkeeping, and docking of space vehicles to support space station operations and the assembly of large structures in space. A suitable prototype, obtained from a commercial vendor, was subjected to limited tests to determine the potential effectiveness of a proximity optical device in spacecraft operations. The constructional features of the device are discussed as well as concepts for its use. Tests results show that a proximity optical device is capable of performing low-light-level viewing services and will enhance manned spacecraft operations.

  18. Negative Offset Operation of Four-Transistor CMOS Image Pixels for Increased Well Capacity and Suppressed Dark Current

    NARCIS (Netherlands)

    Mheen, B.; Song, Y.J.; Theuwissen, J.P.

    2008-01-01

    This letter presents an electrical method to reduce dark current as well as increase well capacity of four-transistor pixels in a CMOS image sensor, utilizing a small negative offset voltage to the gate of the transfer (TX) transistor particularly only when the TX transistor is off. As a result,

  19. HELICoiD project: a new use of hyperspectral imaging for brain cancer detection in real-time during neurosurgical operations

    Science.gov (United States)

    Fabelo, Himar; Ortega, Samuel; Kabwama, Silvester; Callico, Gustavo M.; Bulters, Diederik; Szolna, Adam; Pineiro, Juan F.; Sarmiento, Roberto

    2016-05-01

    Hyperspectral images allow obtaining large amounts of information about the surface of the scene that is captured by the sensor. Using this information and a set of complex classification algorithms is possible to determine which material or substance is located in each pixel. The HELICoiD (HypErspectraL Imaging Cancer Detection) project is a European FET project that has the goal to develop a demonstrator capable to discriminate, with high precision, between normal and tumour tissues, operating in real-time, during neurosurgical operations. This demonstrator could help the neurosurgeons in the process of brain tumour resection, avoiding the excessive extraction of normal tissue and unintentionally leaving small remnants of tumour. Such precise delimitation of the tumour boundaries will improve the results of the surgery. The HELICoiD demonstrator is composed of two hyperspectral cameras obtained from Headwall. The first one in the spectral range from 400 to 1000 nm (visible and near infrared) and the second one in the spectral range from 900 to 1700 nm (near infrared). The demonstrator also includes an illumination system that covers the spectral range from 400 nm to 2200 nm. A data processing unit is in charge of managing all the parts of the demonstrator, and a high performance platform aims to accelerate the hyperspectral image classification process. Each one of these elements is installed in a customized structure specially designed for surgical environments. Preliminary results of the classification algorithms offer high accuracy (over 95%) in the discrimination between normal and tumour tissues.

  20. The positive impact of simultaneous implementation of the BD FocalPoint GS Imaging System and lean principles on the operation of gynecologic cytology.

    Science.gov (United States)

    Wong, Rebecca; Levi, Angelique W; Harigopal, Malini; Schofield, Kevin; Chhieng, David C

    2012-02-01

    Our cytology laboratory, like many others, is under pressure to improve quality and provide test results faster while decreasing costs. We sought to address these issues by introducing new technology and lean principles. To determine the combined impact of the FocalPoint Guided Screener (GS) Imaging System (BD Diagnostics-TriPath, Burlington, North Carolina) and lean manufacturing principles on the turnaround time (TAT) and productivity of the gynecologic cytology operation. We established a baseline measure of the TAT for Papanicolaou tests. We then compared that to the performance after implementing the FocalPoint GS Imaging System and lean principles. The latter included value-stream mapping, workflow modification, and a first in-first out policy. The mean (SD) TAT for Papanicolaou tests before and after the implementation of FocalPoint GS Imaging System and lean principles was 4.38 (1.28) days and 3.20 (1.32) days, respectively. This represented a 27% improvement in the average TAT, which was statistically significant (P implementation of FocalPoint GS Imaging System in conjunction with lean principles resulted in a significant decrease in the average TAT for Papanicolaou tests and a substantial increase in the productivity of cytotechnologists while maintaining the diagnostic quality of gynecologic cytology.

  1. Sealed operation of a rf driven ion source for a compact neutron generator to be used for associated particle imaging.

    Science.gov (United States)

    Wu, Y; Hurley, J P; Ji, Q; Kwan, J W; Leung, K N

    2010-02-01

    We present the recent development of a prototype compact neutron generator to be used in conjunction with the method of associated particle imaging for the purpose of active neutron interrogation. In this paper, the performance and device specifications of these compact generators that employ rf driven ion sources will be discussed. Initial measurements of the generator performance include a beam spot size of 1 mm in diameter and a neutron yield of 2x10(5) n/s with air cooling.

  2. Framework and Bio-Mechanical Model for a Per-Operative Image-Guided Neuronavigator Including 'Brain-Shift' Compensation

    OpenAIRE

    Bucki, Marek; Payan, Yohan

    2006-01-01

    2nd Workshop on Computer Assisted Diagnosis and Surgery, March 2006, Santiago de Chile; In this paper we present a methodology to adress the problem of brain tissue deformation referred to as "brainshift". This deformation occurs throughout a neurosurgery intervention and strongly alters the accuracy of the neuronavigation systems used to date in clinical routine which rely solely on preoperative patient imaging to locate the surgical target, such as a tumour or a functional area. After a gen...

  3. Evaluation of autoradiographs and images of biological objects with the electronically operating image analyzer 'Densitron II'. II. Determination of the specific and total radioactivity of single cells

    Energy Technology Data Exchange (ETDEWEB)

    Hess, J; Korn, U; Freyer, K; Ermisch, A [Karl-Marx-Universitaet, Leipzig (German Democratic Republic). Sektion Biowissenschaften; Akademie der Wissenschaften der DDR, Leipzig. Zentralinstitut fuer Isotopen- und Strahlenforschung)

    1976-01-01

    Using the TV image analyzer Densitron, transparencies and areas can be measured by the grey value discrimination method equidensitometry. The time, necessary for one measurement, is approximately 1 min, the standard deviations do not exceed 2%. Microscopical objects such as single cells can be analyzed by this method. Photo-blackings and areas have been measured in autoradiographs of goldfish brain-sections after injection of /sup 3/H-phenylalanine. As a parallel, blacking and area calibration curves were obtained which allowed a conversion of the relative values into absolute ones. Using this conversion method, neurons of different brain regions were in the range from 104 to 1476..mu..m/sup 2/ in area and from 4.17 to 14.43..mu..Ci . cm/sup -3/ in specific radioactivity. The standard deviations of the absolute values were 6 and 4.5%, respectively. On the basis of these and additional values (thickness of section, number of sections per cell), calculations of the total radioactivity of a cell section or the whole cell can be made.

  4. Assessment of water pollution induced by human activities in Burullus Lake using Landsat 8 operational land imager and GIS

    Directory of Open Access Journals (Sweden)

    Ahmed El-Zeiny

    2017-04-01

    Full Text Available Burullus Lake is the second largest lake along the Mediterranean Sea and represents one of the most subjected lakes to pollution at the delta’s coastline. The present study explores the use of Landsat data and GIS for assessing water pollution at Burullus Lake, Egypt. Multi-spectral Landsat-8 OLI image dated 2015 provided the necessary information to this study. Radiometric and atmospheric corrections were applied to the image. Land use/cover map was obtained to identify natural resources and types of human activities in the area surrounding the Lake. Three previously developed water quality empirical models for BOD, total nitrogen (TN and total phosphorus (TP were applied on the calibrated image. Then, a GIS model was generated to identify areas recording high levels of BOD, TN and TP. Results confirmed that the Lake water is subjected to pollution from multiple sources; particularly domestic and agricultural drains. Shallow water (i.e. Lake Shores, where human activities are influencing, reported high levels of water studied pollutants. The model indicated that south western and north eastern parts of the Lake are the most polluted parts, recording relatively high levels of BOD, TN and TP; >4.46 mg L−1, >18.33 mg L−1 and >15.59 mg L−1, respectively. Results were ascertained based on water quality investigations in relevant research studies on the Lake. It was concluded that Burullus Lake is extensively subjected to interrupting human activities which have a great negative impact on water quality. Also data-observation techniques and water quality empirical models were successful in assessing and mapping water pollution.

  5. Operation of a separated-type x-ray interferometer for phase-contrast x-ray imaging

    Science.gov (United States)

    Yoneyama, Akio; Momose, Atsushi; Seya, Eiichi; Hirano, Keiichi; Takeda, Tohoru; Itai, Yuji

    1999-12-01

    Aiming at large-area phase-contrast x-ray imaging, a separated-type x-ray interferometer system was designed and developed to produce 25×20 mm interference patterns. The skew-symmetric optical system was adopted because of the feasibility of alignment. The rotation between the separated crystal blocks was controlled within a drift of 0.06 nrad using a feedback positioning system. This interferometer generated a 25×15 mm interference pattern with 0.07 nm synchrotron x-rays. A slice of a rabbit's kidney was observed, and its tubular structure could be revealed in a measured phase map.

  6. Negative Offset Operation of Four-Transistor CMOS Image Pixels for Increased Well Capacity and Suppressed Dark Current

    OpenAIRE

    Mheen, B.; Song, Y.J.; Theuwissen, J.P.

    2008-01-01

    This letter presents an electrical method to reduce dark current as well as increase well capacity of four-transistor pixels in a CMOS image sensor, utilizing a small negative offset voltage to the gate of the transfer (TX) transistor particularly only when the TX transistor is off. As a result, using a commercial pixel in a 0.18 ?m CMOS process, the voltage drop due to dark current of the pinned photodiode (PPD) is reduced by 6.1 dB and the well capacity is enhanced by 4.4 dB, which is attri...

  7. Fully automatic detection and segmentation of abdominal aortic thrombus in post-operative CTA images using Deep Convolutional Neural Networks.

    Science.gov (United States)

    López-Linares, Karen; Aranjuelo, Nerea; Kabongo, Luis; Maclair, Gregory; Lete, Nerea; Ceresa, Mario; García-Familiar, Ainhoa; Macía, Iván; González Ballester, Miguel A

    2018-05-01

    Computerized Tomography Angiography (CTA) based follow-up of Abdominal Aortic Aneurysms (AAA) treated with Endovascular Aneurysm Repair (EVAR) is essential to evaluate the progress of the patient and detect complications. In this context, accurate quantification of post-operative thrombus volume is required. However, a proper evaluation is hindered by the lack of automatic, robust and reproducible thrombus segmentation algorithms. We propose a new fully automatic approach based on Deep Convolutional Neural Networks (DCNN) for robust and reproducible thrombus region of interest detection and subsequent fine thrombus segmentation. The DetecNet detection network is adapted to perform region of interest extraction from a complete CTA and a new segmentation network architecture, based on Fully Convolutional Networks and a Holistically-Nested Edge Detection Network, is presented. These networks are trained, validated and tested in 13 post-operative CTA volumes of different patients using a 4-fold cross-validation approach to provide more robustness to the results. Our pipeline achieves a Dice score of more than 82% for post-operative thrombus segmentation and provides a mean relative volume difference between ground truth and automatic segmentation that lays within the experienced human observer variance without the need of human intervention in most common cases. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Post-operative diffusion weighted imaging as a predictor of posterior fossa syndrome permanence in paediatric medulloblastoma.

    Science.gov (United States)

    Chua, Felicia H Z; Thien, Ady; Ng, Lee Ping; Seow, Wan Tew; Low, David C Y; Chang, Kenneth T E; Lian, Derrick W Q; Loh, Eva; Low, Sharon Y Y

    2017-03-01

    Posterior fossa syndrome (PFS) is a serious complication faced by neurosurgeons and their patients, especially in paediatric medulloblastoma patients. The uncertain aetiology of PFS, myriad of cited risk factors and therapeutic challenges make this phenomenon an elusive entity. The primary objective of this study was to identify associative factors related to the development of PFS in medulloblastoma patient post-tumour resection. This is a retrospective study based at a single institution. Patient data and all related information were collected from the hospital records, in accordance to a list of possible risk factors associated with PFS. These included pre-operative tumour volume, hydrocephalus, age, gender, extent of resection, metastasis, ventriculoperitoneal shunt insertion, post-operative meningitis and radiological changes in MRI. Additional variables included molecular and histological subtypes of each patient's medulloblastoma tumour. Statistical analysis was employed to determine evidence of each variable's significance in PFS permanence. A total of 19 patients with appropriately complete data was identified. Initial univariate analysis did not show any statistical significance. However, multivariate analysis for MRI-specific changes reported bilateral DWI restricted diffusion changes involving both right and left sides of the surgical cavity was of statistical significance for PFS permanence. The authors performed a clinical study that evaluated possible risk factors for permanent PFS in paediatric medulloblastoma patients. Analysis of collated results found that post-operative DWI restriction in bilateral regions within the surgical cavity demonstrated statistical significance as a predictor of PFS permanence-a novel finding in the current literature.

  9. Leap Motion Gesture Control With Carestream Software in the Operating Room to Control Imaging: Installation Guide and Discussion.

    Science.gov (United States)

    Pauchot, Julien; Di Tommaso, Laetitia; Lounis, Ahmed; Benassarou, Mourad; Mathieu, Pierre; Bernot, Dominique; Aubry, Sébastien

    2015-12-01

    Nowadays, routine cross-sectional imaging viewing during a surgical procedure requires physical contact with an interface (mouse or touch-sensitive screen). Such contact risks exposure to aseptic conditions and causes loss of time. Devices such as the recently introduced Leap Motion (Leap Motion Society, San Francisco, CA), which enables interaction with the computer without any physical contact, are of wide interest in the field of surgery, but configuration and ergonomics are key challenges for the practitioner, imaging software, and surgical environment. This article aims to suggest an easy configuration of Leap Motion on a PC for optimized use with Carestream Vue PACS v11.3.4 (Carestream Health, Inc, Rochester, NY) using a plug-in (to download at https://drive.google.com/open?id=0B_F4eBeBQc3yNENvTXlnY09qS00&authuser=0) and a video tutorial (https://www.youtube.com/watch?v=yVPTgxg-SIk). Videos of surgical procedure and discussion about innovative gesture control technology and its various configurations are provided in this article. © The Author(s) 2015.

  10. Procrustes-based geometric morphometrics on MRI images: An example of inter-operator bias in 3D landmarks and its impact on big datasets.

    Science.gov (United States)

    Daboul, Amro; Ivanovska, Tatyana; Bülow, Robin; Biffar, Reiner; Cardini, Andrea

    2018-01-01

    Using 3D anatomical landmarks from adult human head MRIs, we assessed the magnitude of inter-operator differences in Procrustes-based geometric morphometric analyses. An in depth analysis of both absolute and relative error was performed in a subsample of individuals with replicated digitization by three different operators. The effect of inter-operator differences was also explored in a large sample of more than 900 individuals. Although absolute error was not unusual for MRI measurements, including bone landmarks, shape was particularly affected by differences among operators, with up to more than 30% of sample variation accounted for by this type of error. The magnitude of the bias was such that it dominated the main pattern of bone and total (all landmarks included) shape variation, largely surpassing the effect of sex differences between hundreds of men and women. In contrast, however, we found higher reproducibility in soft-tissue nasal landmarks, despite relatively larger errors in estimates of nasal size. Our study exemplifies the assessment of measurement error using geometric morphometrics on landmarks from MRIs and stresses the importance of relating it to total sample variance within the specific methodological framework being used. In summary, precise landmarks may not necessarily imply negligible errors, especially in shape data; indeed, size and shape may be differentially impacted by measurement error and different types of landmarks may have relatively larger or smaller errors. Importantly, and consistently with other recent studies using geometric morphometrics on digital images (which, however, were not specific to MRI data), this study showed that inter-operator biases can be a major source of error in the analysis of large samples, as those that are becoming increasingly common in the 'era of big data'.

  11. Star Imager

    DEFF Research Database (Denmark)

    Madsen, Peter Buch; Jørgensen, John Leif; Thuesen, Gøsta

    1997-01-01

    The version of the star imager developed for Astrid II is described. All functions and features are described as well as the operations and the software protocol.......The version of the star imager developed for Astrid II is described. All functions and features are described as well as the operations and the software protocol....

  12. The utility of high-resolution intraoperative MRI in endoscopic transsphenoidal surgery for pituitary macroadenomas: early experience in the Advanced Multimodality Image Guided Operating suite

    Science.gov (United States)

    Zaidi, Hasan A.; De Los Reyes, Kenneth; Barkhoudarian, Garni; Litvack, Zachary N.; Bi, Wenya Linda; Rincon-Torroella, Jordina; Mukundan, Srinivasan; Dunn, Ian F.; Laws, Edward R.

    2016-01-01

    Objective Endoscopic skull base surgery has become increasingly popular among the skull base surgery community, with improved illumination and angled visualization potentially improving tumor resection rates. Intraoperative MRI (iMRI) is used to detect residual disease during the course of the resection. This study is an investigation of the utility of 3-T iMRI in combination with transnasal endoscopy with regard to gross-total resection (GTR) of pituitary macroadenomas. Methods The authors retrospectively reviewed all endoscopic transsphenoidal operations performed in the Advanced Multimodality Image Guided Operating (AMIGO) suite from November 2011 to December 2014. Inclusion criteria were patients harboring presumed pituitary macroadenomas with optic nerve or chiasmal compression and visual loss, operated on by a single surgeon. Results Of the 27 patients who underwent transsphenoidal resection in the AMIGO suite, 20 patients met the inclusion criteria. The endoscope alone, without the use of iMRI, would have correctly predicted 13 (65%) of 20 cases. Gross-total resection was achieved in 12 patients (60%) prior to MRI. Intraoperative MRI helped convert 1 STR and 4 NTRs to GTRs, increasing the number of GTRs from 12 (60%) to 16 (80%). Conclusions Despite advances in visualization provided by the endoscope, the incidence of residual disease can potentially place the patient at risk for additional surgery. The authors found that iMRI can be useful in detecting unexpected residual tumor. The cost-effectiveness of this tool is yet to be determined. PMID:26926058

  13. Monitoring Oilfield Operations and GHG Emissions Sources Using Object-based Image Analysis of High Resolution Spatial Imagery

    Science.gov (United States)

    Englander, J. G.; Brodrick, P. G.; Brandt, A. R.

    2015-12-01

    Fugitive emissions from oil and gas extraction have become a greater concern with the recent increases in development of shale hydrocarbon resources. There are significant gaps in the tools and research used to estimate fugitive emissions from oil and gas extraction. Two approaches exist for quantifying these emissions: atmospheric (or 'top down') studies, which measure methane fluxes remotely, or inventory-based ('bottom up') studies, which aggregate leakage rates on an equipment-specific basis. Bottom-up studies require counting or estimating how many devices might be leaking (called an 'activity count'), as well as how much each device might leak on average (an 'emissions factor'). In a real-world inventory, there is uncertainty in both activity counts and emissions factors. Even at the well level there are significant disagreements in data reporting. For example, some prior studies noted a ~5x difference in the number of reported well completions in the United States between EPA and private data sources. The purpose of this work is to address activity count uncertainty by using machine learning algorithms to classify oilfield surface facilities using high-resolution spatial imagery. This method can help estimate venting and fugitive emissions sources from regions where reporting of oilfield equipment is incomplete or non-existent. This work will utilize high resolution satellite imagery to count well pads in the Bakken oil field of North Dakota. This initial study examines an area of ~2,000 km2 with ~1000 well pads. We compare different machine learning classification techniques, and explore the impact of training set size, input variables, and image segmentation settings to develop efficient and robust techniques identifying well pads. We discuss the tradeoffs inherent to different classification algorithms, and determine the optimal algorithms for oilfield feature detection. In the future, the results of this work will be leveraged to be provide activity

  14. Multi-temporal change image inference towards false alarms reduction for an operational photogrammetric rockfall detection system

    Science.gov (United States)

    Partsinevelos, Panagiotis; Kallimani, Christina; Tripolitsiotis, Achilleas

    2015-06-01

    Rockfall incidents affect civil security and hamper the sustainable growth of hard to access mountainous areas due to casualties, injuries and infrastructure loss. Rockfall occurrences cannot be easily prevented, whereas previous studies for rockfall multiple sensor early detection systems have focused on large scale incidents. However, even a single rock may cause the loss of a human life along transportation routes thus, it is highly important to establish methods for the early detection of small-scale rockfall incidents. Terrestrial photogrammetric techniques are prone to a series of errors leading to false alarm incidents, including vegetation, wind, and non relevant change in the scene under consideration. In this study, photogrammetric monitoring of rockfall prone slopes is established and the resulting multi-temporal change imagery is processed in order to minimize false alarm incidents. Integration of remote sensing imagery analysis techniques is hereby applied to enhance early detection of a rockfall. Experimental data demonstrated that an operational system able to identify a 10-cm rock movement within a 10% false alarm rate is technically feasible.

  15. 3D surface rendering of images from multiple MR pulse sequences in the pre-operative evaluation of hepatic lesions

    International Nuclear Information System (INIS)

    Bjerner, T.; Johansson, L.; Ahlstroem, H.; Haglund, U.

    1998-01-01

    Purpose: To develop a method for making three-dimensional (3D) reconstructions of liver vessels and hepatic lesions from different MR data sets. Material and Methods: To reduce the time required for segmentation and reconstructions, we used T1, T2 and phase contrast angiography, optimised for liver, lesion and vessels respectively. Following segmentation and reconstruction, the different volumes were combined on the same workstation and presented to the surgeon. Results and Conclusion: Segmentation and reconstruction took 1-2 h. To be able to combine the volumes from the different data sets, certain criteria had to be fulfilled: (a) the field of view had to be constant; (b) the same volume had to be scanned every time which meant that the slice thickness and the number of slices could be adjusted as long as the volume covered was the same; and (c) the positioning of each volume had to be identical between every scan. The resulting 3D reconstruction gave the surgeon a clear appreciation of the different lesions and their relation to the different liver segments in the pre-operative planning of hepatic resections. (orig.)

  16. Early post-operative magnetic resonance imaging in glioblastoma: correlation among radiological findings and overall survival in 60 patients

    Energy Technology Data Exchange (ETDEWEB)

    Majos, Carles [IDI Centre Bellvitge, HU de Bellvitge, Department of Radiology, Barcelona (Spain); Centro de Investigacion en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona (Spain); Hospital Duran i Reynals, IDI Centre Bellvitge, Barcelona (Spain); Cos, Monica; Castaner, Sara [IDI Centre Bellvitge, HU de Bellvitge, Department of Radiology, Barcelona (Spain); Gil, Miguel [ICO l' Hospitalet, HU de Bellvitge, Department of Medical Onclogy, Barcelona (Spain); Plans, Gerard [HU de Bellvitge, Department of Neurosurgery, Barcelona (Spain); Lucas, Anna [ICO l' Hospitalet, HU de Bellvitge, Department of Radiotherapy Oncology, Barcelona (Spain); Bruna, Jordi [HU de Bellvitge, Department of Neurology, Barcelona (Spain); Aguilera, Carles [IDI Centre Bellvitge, HU de Bellvitge, Department of Radiology, Barcelona (Spain); Centro de Investigacion en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona (Spain)

    2016-04-15

    To evaluate early post-operative magnetic resonance (EPMR) as a prognostic tool after resection of glioblastoma. Sixty EPMR examinations were evaluated for perioperative infarct, tumour growth between diagnosis and EPMR, contrast enhancement pattern, and extent of resection (EOR). The EOR was approached with the subjective evaluation of radiologists and by quantifying volumes. These parameters were tested as predictors of survival using the Kaplan-Meier method. Contrast enhancement was found in 59 patients (59/60; 98 %). Showing a thin-linear pattern of enhancement was the most favourable finding. Patients with this pattern survived longer than patients with thick-linear (median overall survival (OS) thin-linear=609 days; thick-linear=432 days; P =.023) or nodular (median OS = 318 days; P =.001) enhancements. The subjective evaluation of the EOR performed better than its quantification. Patients survived longer when resection was total (median OS total resection=609 days; subtotal=371 days; P =.001). When resection was subtotal, patients survived longer if it was superior to 95 % (median OS resection superior to 95 %=559 days; inferior to 95 %=256 days; P =.034). EPMR provides valuable prognostic information after surgical resection of glioblastomas. A thin-linear pattern of contrast enhancement is the most favourable finding. Further prognostic stratification may be obtained by assessing the EOR. (orig.)

  17. Early post-operative magnetic resonance imaging in glioblastoma: correlation among radiological findings and overall survival in 60 patients

    International Nuclear Information System (INIS)

    Majos, Carles; Cos, Monica; Castaner, Sara; Gil, Miguel; Plans, Gerard; Lucas, Anna; Bruna, Jordi; Aguilera, Carles

    2016-01-01

    To evaluate early post-operative magnetic resonance (EPMR) as a prognostic tool after resection of glioblastoma. Sixty EPMR examinations were evaluated for perioperative infarct, tumour growth between diagnosis and EPMR, contrast enhancement pattern, and extent of resection (EOR). The EOR was approached with the subjective evaluation of radiologists and by quantifying volumes. These parameters were tested as predictors of survival using the Kaplan-Meier method. Contrast enhancement was found in 59 patients (59/60; 98 %). Showing a thin-linear pattern of enhancement was the most favourable finding. Patients with this pattern survived longer than patients with thick-linear (median overall survival (OS) thin-linear=609 days; thick-linear=432 days; P =.023) or nodular (median OS = 318 days; P =.001) enhancements. The subjective evaluation of the EOR performed better than its quantification. Patients survived longer when resection was total (median OS total resection=609 days; subtotal=371 days; P =.001). When resection was subtotal, patients survived longer if it was superior to 95 % (median OS resection superior to 95 %=559 days; inferior to 95 %=256 days; P =.034). EPMR provides valuable prognostic information after surgical resection of glioblastomas. A thin-linear pattern of contrast enhancement is the most favourable finding. Further prognostic stratification may be obtained by assessing the EOR. (orig.)

  18. Receiver operating characteristics of diagnostic efficacy of resting left ventricular performance (evaluating with a non-imaging ECG gated scintillation detector - nuclear stethoscope)

    International Nuclear Information System (INIS)

    Kotlyarov, E.V.; Reba, R.C.; Lindsay, J.

    1983-01-01

    Receiver operating characteristic (ROC) analysis of left ventricular performance at rest was applied to evaluate diagnostic utility of non-imaging nuclear detector (''Nuclear Stethoscope''), for screening patients with coronary artery disease (CAD). Thirty-one patients without CAD and normal rest and stress radionuclide ventriculography (MUGA) were used as a control group. Another 62 patients with abnormal left ventricular reserve and segmental wall motion abnormalities at rest were also studied. All 93 patients were studied with the Nuclear Stethoscope (30 minutes after conventional MUGA testing) both in beat-to-beat and gated equilibrium modes. ROC analysis showed that along with ejection fraction, stroke and end-diastolic volumes, evaluation of the left ventricular filling phase has a great potential for the identification of patients with a segmental wall motion abnormality and, therefore, significant CAD

  19. Additional value of diffusion-weighted imaging to evaluate multifocal and multicentric breast cancer detected using pre-operative breast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Eun; Park, Eun Kyung; Cho, Kyu Ran; Cho, Sung Bum [Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seo, Bo Kyoung [Korea University Ansan Hospital, Korea University College of Medicine, Department of Radiology, Ansan (Korea, Republic of); Woo, Ok Hee [Korea University Guro Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Jung, Seung Pil [Korea University Anam Hospital, Korea University College of Medicine, Department of Surgery, Seoul (Korea, Republic of)

    2017-11-15

    To investigate whether diffusion-weighted imaging (DWI) aids pre-operative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to evaluate additional lesions in breast cancer patients. DCE-MRI and DWI were performed on 131 lesions, with available histopathological results. The apparent diffusion coefficient (ADC) of each lesion was measured, and the cut-off value for differentiation between malignant and benign lesions was calculated. A protocol combining the ADC cut-off value with DCE-MRI was validated in a cohort of 107 lesions in 77 patients. When an ADC cut-off value of 1.11 x 10{sup -3} mm{sup 2}/s from the development cohort was applied to the additional lesions in the validation cohort, the specificity increased from 18.9% to 67.6% (P < 0.001), and the diagnostic accuracy increased from 61.7% to 82.2% (P = 0.05), without significant loss of sensitivity (98.6% vs. 90.0%, P = 0.07). The negative predictive values of lesions in the same quadrant had decreased, as had those of lesions ≥1 cm in diameter. The ADC cut-off value in the validation cohort was 1.05 x 10{sup -3} mm{sup 2}/s. Additional implementation of DWI for breast lesions in pre-operative MRI can help to obviate unnecessary biopsies by increasing specificity. However, to avoid missing cancers, clinicians should closely monitor lesions located in the same quadrant or lesions ≥1 cm. (orig.)

  20. Combining Magnetic Resonance Imaging (MRI) and Medical Infrared Thermography (MIT) in the pre- and per-operating management of severe Hidradenitis Suppurativa (HS).

    Science.gov (United States)

    Derruau, Stéphane; Renard, Yohann; Pron, Hervé; Taiar, Redha; Abdi, Ellie; Polidori, Guillaume; Lorimier, Sandrine

    2018-05-12

    Hidradenitis suppurativa (HS) is a chronic, inflammatory, and recurrent skin disease. Surgical excision of wounds appears to be the only curative treatment for the prevention of recurrence of moderate to severe stages. Magnetic resonance imaging (MRI) is a standard reference examination for the detection of HS peri-anal inflammatory fistula. In this case study, the use of real-time medical infrared thermography, in combination with MRI as appropriate imaging, is proposed. The aim is to assist surgeons in the pre- and peri-surgical management of severe perianal hidradenitis suppurativa with the intent to ensure that all diseased lesions were removed during surgery and therefore to limit recurrence. The results show that medical infrared thermography (MIT), coupled with MRI, could be highly effective strategy to address thermally distinguished health tissues and inflammatory sites during excision, as characterised by differential increases in temperature. Medical infrared thermography could be used to check the total excision of inflammatory lesions as a noninvasive method that is not painful, not radiant, and is easily transportable during surgery. Ultimately, this method could be complementary with MRI in providing clinicians with objective data on the status of tissues below the perianal skin surface in the pre- and per-operating management of severe hidradenitis suppurativa. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Clinical evaluation of cardiovascular disease by gated-MRI (magnetic resonance imaging) in the operating field of 0.35 and 1.5 Tesla

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Naito, Hiroaki; Yamada, Yukinori; Kozuka, Takahiro

    1985-01-01

    To evaluate the clinical usefulness of magnetic resonance imaging (MRI) in the cardiovascular disease, 21 patients were examined using 0.35 and 1.5 Tesla superconductive type (Magnetom, Siemens). In our study, all patients were performed using ECG-gated MRI. Therefore, the cardiac chambers were discriminated clearly from the myocardial wall compared to non-gated MRI. Gated-MRI was performed in 6 normal persons in the operating field at 0.35 and 1.5 Tesla. The image of the latter showed superior than that of the former because of high S/N ratio. In myocardial infarction, infarct area was demonstrated as the wall thinning in 4 of 5 patients. Hypertrophic cardiomyopathy showed thickened left ventricle associated with its narrowed cavity in 7 patients. In the remaining such as congenital and valvular heart disease, global and regional cardiac morphology were assessed noninvasively by gated MRI. In addition, gated MRI was also applied to the diagnosis of peripheral vascular diseases. In dissecting aneurysm, double channels with an intimal flap in the aorta were clearly visualized. And in the aortitis syndrome, aortic dilatation and stenosis were also assessed noninvasively. In conclusion, gated MRI in diagnosing various abnormalities of cardiovascular disease was confirmed. (author)

  2. The SENSE-Isomorphism Theoretical Image Voxel Estimation (SENSE-ITIVE) Model for Reconstruction and Observing Statistical Properties of Reconstruction Operators

    Science.gov (United States)

    Bruce, Iain P.; Karaman, M. Muge; Rowe, Daniel B.

    2012-01-01

    The acquisition of sub-sampled data from an array of receiver coils has become a common means of reducing data acquisition time in MRI. Of the various techniques used in parallel MRI, SENSitivity Encoding (SENSE) is one of the most common, making use of a complex-valued weighted least squares estimation to unfold the aliased images. It was recently shown in Bruce et al. [Magn. Reson. Imag. 29(2011):1267–1287] that when the SENSE model is represented in terms of a real-valued isomorphism, it assumes a skew-symmetric covariance between receiver coils, as well as an identity covariance structure between voxels. In this manuscript, we show that not only is the skew-symmetric coil covariance unlike that of real data, but the estimated covariance structure between voxels over a time series of experimental data is not an identity matrix. As such, a new model, entitled SENSE-ITIVE, is described with both revised coil and voxel covariance structures. Both the SENSE and SENSE-ITIVE models are represented in terms of real-valued isomorphisms, allowing for a statistical analysis of reconstructed voxel means, variances, and correlations resulting from the use of different coil and voxel covariance structures used in the reconstruction processes to be conducted. It is shown through both theoretical and experimental illustrations that the miss-specification of the coil and voxel covariance structures in the SENSE model results in a lower standard deviation in each voxel of the reconstructed images, and thus an artificial increase in SNR, compared to the standard deviation and SNR of the SENSE-ITIVE model where both the coil and voxel covariances are appropriately accounted for. It is also shown that there are differences in the correlations induced by the reconstruction operations of both models, and consequently there are differences in the correlations estimated throughout the course of reconstructed time series. These differences in correlations could result in meaningful

  3. Applications for a hybrid operating room in thoracic surgery: from multidisciplinary procedures to --image-guided video-assisted thoracoscopic surgery.

    Science.gov (United States)

    Terra, Ricardo Mingarini; Andrade, Juliano Ribeiro; Mariani, Alessandro Wasum; Garcia, Rodrigo Gobbo; Succi, Jose Ernesto; Soares, Andrey; Zimmer, Paulo Marcelo

    2016-01-01

    The concept of a hybrid operating room represents the union of a high-complexity surgical apparatus with state-of-the-art radiological tools (ultrasound, CT, fluoroscopy, or magnetic resonance imaging), in order to perform highly effective, minimally invasive procedures. Although the use of a hybrid operating room is well established in specialties such as neurosurgery and cardiovascular surgery, it has rarely been explored in thoracic surgery. Our objective was to discuss the possible applications of this technology in thoracic surgery, through the reporting of three cases. RESUMO O conceito de sala híbrida traduz a união de um aparato cirúrgico de alta complexidade com recursos radiológicos de última geração (ultrassom, TC, radioscopia e/ou ressonância magnética), visando a realização de procedimentos minimamente invasivos e altamente eficazes. Apesar de bem estabelecido em outras especialidades, como neurocirurgia e cirurgia cardiovascular, o uso da sala hibrida ainda é pouco explorado na cirurgia torácica. Nosso objetivo foi discutir as aplicações e as possibilidades abertas por essa tecnologia na cirurgia torácica através do relato de três casos.

  4. Effect of S-1 chemotherapy and FP chemotherapy on prognosis, imaging characteristics and serum marker levels after operation for gastric carcinoma

    Directory of Open Access Journals (Sweden)

    Qing-Hao Gong

    2016-09-01

    Full Text Available Objective: To analyze the effect of S-1 chemotherapy and FP chemotherapy on prognosis, imaging characteristics and serum marker levels after operation for gastric carcinoma. Methods: A total of 68 patients with gastric cancer who underwent radical surgery were included in the study and divided into observation group and control group patients (n=34 according to random number table. Control group received FP chemotherapy, observation group received S-1 chemotherapy, and then differences in serum tumor markers, illnessrelated factors, nutrition indexes and T cell immune function values were compared between two groups. Results: After observation group received systematic chemotherapy, serum tumor markers such as MMP-9, MMP-2, MG7-Ag, TSGF, CA72-4, CA19-9, TP and DpD as well as illness-related factors such as DKK1, MK, Leptin, Exosome and OPN were all lower than those of control group (P<0.05; nutrition and cellular immune function indexes such as TP, ALB, PA, CD4+ T and CD4+ T/ CD8+ T values were higher than those of control group and CD8+ T value was lower than that of control group (P<0.05. Conclusions: S-1 chemotherapy after operation for gastric carcinoma can inhibit the tumor activity and optimize patients’ overall condition, and it has positive clinical significance.

  5. Study of factors controlling exposure dose and image quality of C-arm in operation room according to detector size of it (Mainly L-Spine AP study)

    Energy Technology Data Exchange (ETDEWEB)

    Chui, Sung Hyun; Jo, Hwang Woo [Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of); Chun, Woon Kwan; Song, Ha Jin [Dept. of Nuclear Engineering, Chosun University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Choi, Eun Jin [Dept. of Public Health and Medicine, Dongshin University, Naju (Korea, Republic of)

    2015-02-15

    Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed

  6. Can pre-operative axial CT imaging predict syndesmosis instability in patients sustaining ankle fractures? Seven years' experience in a tertiary trauma center

    Energy Technology Data Exchange (ETDEWEB)

    Yeung, Tsz Wai; Chan, Chung Yan Grace; Chan, Wun Cheung Samuel; Yuen, Ming Keung [Tuen Mun Hospital, Department of Radiology, Tuen Mun (China); Yeung, Yuk Nam [Tune Mun Hospital, Department of Orthopaedics and Traumatology, Tuen Mun (China)

    2015-06-01

    The purpose of this study is to explore the diagnostic accuracy of CT measurements in predicting syndesmosis instability of injured ankle, with correlation to operative findings. From July 2006 to June 2013, 123 patients presented to a single tertiary hospital who received pre-operative CT for ankle fractures were retrospectively reviewed. All patients underwent open reduction and internal fixation for fractures and intra-operative syndesmosis integrity tests. The morphology of incisura fibularis was categorized as deep or shallow. The tibiofibular distance (TFD) between the medial border of the fibula and the nearest point of the lateral border of tibia were measured at anterior (aTFD), middle (mTFD), posterior (pTFD), and maximal (maxTFD) portions across the syndesmosis on axial CT images at 10 mm proximal to the tibial plafond. Statistical analysis was performed with independent samples t test and ROC curve analysis. Intraobserver reproducibility and inter-observers agreement were also evaluated. Of the 123 patients, 39 (31.7 %) were operatively diagnosed with syndesmosis instability. No significant difference of incisura fibularis morphology (deep or shallow) and TFDs was demonstrated respective to genders. The axial CT measurements were significantly higher in ankles diagnosed with syndesmosis instability than the group without (maxTFD means 7.2 ± 2.96 mm vs. 4.6 ± 1.4 mm, aTFD mean 4.9 ± 3.7 mm vs. 1.8 ± 1.4 mm, mTFD mean 5.3 ± 2.4 mm vs. 3.2 ± 1.6 mm, pTFD mean 5.3 ± 1.8 mm vs. 4.1 ± 1.3 mm, p < 0.05). Their respective cutoff values with best sensitivity and specificity were calculated; the aTFD (AUC 0.798) and maxTFD (AUC 0.794) achieved the highest diagnostic accuracy. The optimal cutoff levels were aTFD = 4 mm (sensitivity, 56.4 %; specificity, 91.7 %) and maxTFD = 5.65 mm (sensitivity, 74.4 %; specificity, 79.8 %). The inter-observer agreement was good for all aTFD, mTFD, pTFD, and maxTFD measurements (ICC 0.959, 0.799, 0.783, and 0.865). The ICC

  7. Can pre-operative axial CT imaging predict syndesmosis instability in patients sustaining ankle fractures? Seven years' experience in a tertiary trauma center

    International Nuclear Information System (INIS)

    Yeung, Tsz Wai; Chan, Chung Yan Grace; Chan, Wun Cheung Samuel; Yuen, Ming Keung; Yeung, Yuk Nam

    2015-01-01

    The purpose of this study is to explore the diagnostic accuracy of CT measurements in predicting syndesmosis instability of injured ankle, with correlation to operative findings. From July 2006 to June 2013, 123 patients presented to a single tertiary hospital who received pre-operative CT for ankle fractures were retrospectively reviewed. All patients underwent open reduction and internal fixation for fractures and intra-operative syndesmosis integrity tests. The morphology of incisura fibularis was categorized as deep or shallow. The tibiofibular distance (TFD) between the medial border of the fibula and the nearest point of the lateral border of tibia were measured at anterior (aTFD), middle (mTFD), posterior (pTFD), and maximal (maxTFD) portions across the syndesmosis on axial CT images at 10 mm proximal to the tibial plafond. Statistical analysis was performed with independent samples t test and ROC curve analysis. Intraobserver reproducibility and inter-observers agreement were also evaluated. Of the 123 patients, 39 (31.7 %) were operatively diagnosed with syndesmosis instability. No significant difference of incisura fibularis morphology (deep or shallow) and TFDs was demonstrated respective to genders. The axial CT measurements were significantly higher in ankles diagnosed with syndesmosis instability than the group without (maxTFD means 7.2 ± 2.96 mm vs. 4.6 ± 1.4 mm, aTFD mean 4.9 ± 3.7 mm vs. 1.8 ± 1.4 mm, mTFD mean 5.3 ± 2.4 mm vs. 3.2 ± 1.6 mm, pTFD mean 5.3 ± 1.8 mm vs. 4.1 ± 1.3 mm, p < 0.05). Their respective cutoff values with best sensitivity and specificity were calculated; the aTFD (AUC 0.798) and maxTFD (AUC 0.794) achieved the highest diagnostic accuracy. The optimal cutoff levels were aTFD = 4 mm (sensitivity, 56.4 %; specificity, 91.7 %) and maxTFD = 5.65 mm (sensitivity, 74.4 %; specificity, 79.8 %). The inter-observer agreement was good for all aTFD, mTFD, pTFD, and maxTFD measurements (ICC 0.959, 0.799, 0.783, and 0.865). The ICC

  8. Is there a role for pre-operative contrast-enhanced magnetic resonance imaging for radical surgery in malignant pleural mesothelioma?

    Science.gov (United States)

    Stewart, Duncan; Waller, David; Edwards, John; Jeyapalan, Kanagaratnam; Entwisle, James

    2003-12-01

    To assess the use of contrast-enhanced magnetic resonance imaging (CEMRI) in addition to computed tomography in the pre-operative assessment of patients for radical surgery in malignant pleural mesothelioma. Over a 45-month period, 51 of 76 patients assessed (69 men and seven women), underwent extra-pleural pneumonectomy or radical pleurectomy/decortication. Post-operative pathological stage was correlated with radiological staging, with particular emphasis on tumour resectability. Seventeen (22%) patients were found on CEMRI to have unresectable, but histologically unconfirmed disease, not previously seen on CT. Fifty-one (67%) patients proceeded to radical surgery, but pathological nodal data were incomplete in three, so excluding these patients from further analyses. The median pre-operative interval after CEMRI was 17 days. Two patients were found to have unexpectedly extensive disease at thoracotomy, thus the sensitivity of CEMRI for prediction of resectability was 97%. Using the International Mesothelioma Interest Group system, tumour stage was correctly predicted by CEMRI in 48% of patients, but understaged in 50% of cases, largely due to the underestimation of pericardial involvement, but this did not affect resectability and had no significant effect on prognosis. Nodal stage was correctly identified in 60% of patients. CEMRI was successful in predicting pathological tumour stage T3 or less (sensitivity of 85%; specificity of 100%), but less so in identifying tumour stage T2 or less (sensitivity of 23%; specificity of 96%) or N2 nodal disease (sensitivity 66%; specificity 73%). CEMRI is most useful in the differentiation of T3 and T4 disease and may be unnecessary at earlier stages. Its multiplanar tumour localisation abilities are of value in the assessment of resectability. It is unlikely to contribute significantly to nodal staging, but it remains a valuable adjunct in the selection of patients for radical surgery.

  9. The Small Whiskbroom Imager for atmospheric compositioN monitorinG (SWING) and its operations from an unmanned aerial vehicle (UAV) during the AROMAT campaign

    Science.gov (United States)

    Merlaud, Alexis; Tack, Frederik; Constantin, Daniel; Georgescu, Lucian; Maes, Jeroen; Fayt, Caroline; Mingireanu, Florin; Schuettemeyer, Dirk; Meier, Andreas Carlos; Schönardt, Anja; Ruhtz, Thomas; Bellegante, Livio; Nicolae, Doina; Den Hoed, Mirjam; Allaart, Marc; Van Roozendael, Michel

    2018-01-01

    The Small Whiskbroom Imager for atmospheric compositioN monitorinG (SWING) is a compact remote sensing instrument dedicated to mapping trace gases from an unmanned aerial vehicle (UAV). SWING is based on a compact visible spectrometer and a scanning mirror to collect scattered sunlight. Its weight, size, and power consumption are respectively 920 g, 27 cm × 12 cm × 8 cm, and 6 W. SWING was developed in parallel with a 2.5 m flying-wing UAV. This unmanned aircraft is electrically powered, has a typical airspeed of 100 km h-1, and can operate at a maximum altitude of 3 km. We present SWING-UAV experiments performed in Romania on 11 September 2014 during the Airborne ROmanian Measurements of Aerosols and Trace gases (AROMAT) campaign, which was dedicated to test newly developed instruments in the context of air quality satellite validation. The UAV was operated up to 700 m above ground, in the vicinity of the large power plant of Turceni (44.67° N, 23.41° E; 116 m a. s. l. ). These SWING-UAV flights were coincident with another airborne experiment using the Airborne imaging differential optical absorption spectroscopy (DOAS) instrument for Measurements of Atmospheric Pollution (AirMAP), and with ground-based DOAS, lidar, and balloon-borne in situ observations. The spectra recorded during the SWING-UAV flights are analysed with the DOAS technique. This analysis reveals NO2 differential slant column densities (DSCDs) up to 13±0.6×1016 molec cm-2. These NO2 DSCDs are converted to vertical column densities (VCDs) by estimating air mass factors. The resulting NO2 VCDs are up to 4.7±0.4×1016 molec cm-2. The water vapour DSCD measurements, up to 8±0.15×1022 molec cm-2, are used to estimate a volume mixing ratio of water vapour in the boundary layer of 0.013±0.002 mol mol-1. These geophysical quantities are validated with the coincident measurements.

  10. The Small Whiskbroom Imager for atmospheric compositioN monitorinG (SWING and its operations from an unmanned aerial vehicle (UAV during the AROMAT campaign

    Directory of Open Access Journals (Sweden)

    A. Merlaud

    2018-01-01

    Full Text Available The Small Whiskbroom Imager for atmospheric compositioN monitorinG (SWING is a compact remote sensing instrument dedicated to mapping trace gases from an unmanned aerial vehicle (UAV. SWING is based on a compact visible spectrometer and a scanning mirror to collect scattered sunlight. Its weight, size, and power consumption are respectively 920 g, 27 cm  ×  12 cm  ×  8 cm, and 6 W. SWING was developed in parallel with a 2.5 m flying-wing UAV. This unmanned aircraft is electrically powered, has a typical airspeed of 100 km h−1, and can operate at a maximum altitude of 3 km. We present SWING-UAV experiments performed in Romania on 11 September 2014 during the Airborne ROmanian Measurements of Aerosols and Trace gases (AROMAT campaign, which was dedicated to test newly developed instruments in the context of air quality satellite validation. The UAV was operated up to 700 m above ground, in the vicinity of the large power plant of Turceni (44.67° N, 23.41° E; 116 m a. s. l. . These SWING-UAV flights were coincident with another airborne experiment using the Airborne imaging differential optical absorption spectroscopy (DOAS instrument for Measurements of Atmospheric Pollution (AirMAP, and with ground-based DOAS, lidar, and balloon-borne in situ observations. The spectra recorded during the SWING-UAV flights are analysed with the DOAS technique. This analysis reveals NO2 differential slant column densities (DSCDs up to 13±0.6×1016 molec cm−2. These NO2 DSCDs are converted to vertical column densities (VCDs by estimating air mass factors. The resulting NO2 VCDs are up to 4.7±0.4×1016 molec cm−2. The water vapour DSCD measurements, up to 8±0.15×1022 molec cm−2, are used to estimate a volume mixing ratio of water vapour in the boundary layer of 0.013±0.002 mol mol−1. These geophysical quantities are validated with the coincident measurements.

  11. Elaboration and implementation of standard operational procedure for quality assurance of cone beam CT image in radiotherapy; Elaboracao e implementacao de procedimentos operacionais padrao para controle de qualidade da imagem CBCT em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Bonatto, Larisse N.; Estacio, Daniela R.; Lopes, Juliane S.; Sansson, Angela; Duarte, Lucas O.; Sbaraini, Patricia, E-mail: larisse.neumann@pucrs.br [Hospital Sao Lucas (PUC-RS), Porto Alegre, RS (Brazil). Servico de Radioterapia; Silva, Ana M. Marques da; Streck, Elaine E. [Pontificia Universidade Catolica do Rio Grande do Sukl (PUC-RS), Porto Alegre, RS (Brazil). Faculdade de Fisica

    2016-07-01

    The aim of this paper is to present the implementation of image quality control of the computed tomography cone beam (CBCT), generated by the On-Board Imager device, and integrated into the linear accelerator Trilogy. To this end, standard operating procedures (SOP) based on the literature and Catphan 504 phantom and On-Board Imager manuals were drafted. The following SOPs were prepared: acquisition of CBCT image; CT number linearity; uniformity; spatial resolution; low contrast resolution; spatial linearity; slice thickness. The validation of the procedures from an experimental acquisition of the phantom was performed. The results, obtained in the SOP validation, are in accordance with the parameters established by the phantom manufacturer, as well as those obtained in the On-Board Imager device acceptance. (author)

  12. Elaboration and implementation of standard operational procedure for quality assurance of cone beam CT image in radiotherapy; Elaboracao e implementacao de procedimentos operacionais padrao para controle de qualidade da imagem CBCT em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Bonatto, Larisse N.; Estacio, Daniela R.; Lopes, Juliane S.; Sansson, Angela; Duarte, Lucas O.; Sbaraini, Patricia; Silva, Ana M. Marques da; Streck, Elaine E., E-mail: larisse.neumann@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil)

    2016-07-01

    The objective of this article is to present the implementation of the quality Control of Cone Beam Computed Tomography (CBCT) image, generated by the On-Board Imager, integrated with the linear accelerator Trilogy. Standard operating procedures (POPs) have been developed based on the literature and manuals of the simulator object Catphan 504 and the On-Board Imager. The following POPs were developed: acquisition of the CBCT image; linearity of CT number; uniformity; spatial resolution; low contrast resolution; spatial linearity; thickness of the cut. The validation of the elaborated procedures was done from an experimental acquisition of the simulator object. The results obtained in the validation of the POPs are in compliance with the parameters established by the manufacturer of the simulator object, as well as those obtained in the acceptance of the On-Board Imager device.

  13. Camera-augmented mobile C-arm (CamC): A feasibility study of augmented reality imaging in the operating room.

    Science.gov (United States)

    von der Heide, Anna Maria; Fallavollita, Pascal; Wang, Lejing; Sandner, Philipp; Navab, Nassir; Weidert, Simon; Euler, Ekkehard

    2018-04-01

    In orthopaedic trauma surgery, image-guided procedures are mostly based on fluoroscopy. The reduction of radiation exposure is an important goal. The purpose of this work was to investigate the impact of a camera-augmented mobile C-arm (CamC) on radiation exposure and the surgical workflow during a first clinical trial. Applying a workflow-oriented approach, 10 general workflow steps were defined to compare the CamC to traditional C-arms. The surgeries included were arbitrarily identified and assigned to the study. The evaluation criteria were radiation exposure and operation time for each workflow step and the entire surgery. The evaluation protocol was designed and conducted in a single-centre study. The radiation exposure was remarkably reduced by 18 X-ray shots 46% using the CamC while keeping similar surgery times. The intuitiveness of the system, its easy integration into the surgical workflow, and its great potential to reduce radiation have been demonstrated. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Shifts in Forest Structure in Northwest Montana from 1972 to 2015 Using the Landsat Archive from Multispectral Scanner to Operational Land Imager

    Directory of Open Access Journals (Sweden)

    Shannon L. Savage

    2018-03-01

    Full Text Available There is a pressing need to map changes in forest structure from the earliest time period possible given forest management policies and accelerated disturbances from climate change. The availability of Landsat data from over four decades helps researchers study an ecologically meaningful length of time. Forest structure is most often mapped utilizing lidar data, however these data are prohibitively expensive and cover a narrow temporal window relative to the Landsat archive. Here we describe a technique to use the entire length of the Landsat archive from Multispectral Scanner to Operational Land Imager (M2O to produce three novel outcomes: (1 we used the M2O dataset and standard change vector analysis methods to classify annual forest structure in northwestern Montana from 1972 to 2015, (2 we improved the accuracy of each yearly forest structure classification by applying temporal continuity rules to the whole time series, with final accuracies ranging from 97% to 68% respectively for two and six-category classifications, and (3 we demonstrated the importance of pre-1984 Landsat data for long-term change studies. As the Landsat program continues to acquire Earth imagery into the foreseeable future, time series analyses that aid in classifying forest structure accurately will be key to the success of any land management changes in the future.

  15. Soil moisture mapping using Sentinel 1 images: the proposed approach and its preliminary validation carried out in view of an operational product

    Science.gov (United States)

    Paloscia, S.; Pettinato, S.; Santi, E.; Pierdicca, N.; Pulvirenti, L.; Notarnicola, C.; Pace, G.; Reppucci, A.

    2011-11-01

    The main objective of this research is to develop, test and validate a soil moisture (SMC)) algorithm for the GMES Sentinel-1 characteristics, within the framework of an ESA project. The SMC product, to be generated from Sentinel-1 data, requires an algorithm able to process operationally in near-real-time and deliver the product to the GMES services within 3 hours from observations. Two different complementary approaches have been proposed: an Artificial Neural Network (ANN), which represented the best compromise between retrieval accuracy and processing time, thus allowing compliance with the timeliness requirements and a Bayesian Multi-temporal approach, allowing an increase of the retrieval accuracy, especially in case where little ancillary data are available, at the cost of computational efficiency, taking advantage of the frequent revisit time achieved by Sentinel-1. The algorithm was validated in several test areas in Italy, US and Australia, and finally in Spain with a 'blind' validation. The Multi-temporal Bayesian algorithm was validated in Central Italy. The validation results are in all cases very much in line with the requirements. However, the blind validation results were penalized by the availability of only VV polarization SAR images and MODIS lowresolution NDVI, although the RMS is slightly > 4%.

  16. Hydration and dehydration cycles in polymer electrolyte fuel cells operated with wet anode and dry cathode feed: A neutron imaging and modeling study

    Science.gov (United States)

    García-Salaberri, P. A.; Sánchez, D. G.; Boillat, P.; Vera, M.; Friedrich, K. A.

    2017-08-01

    Proper water management plays an essential role in the performance and durability of Polymer Electrolyte Fuel Cells (PEFCs), but it is challenged by the variety of water transport phenomena that take place in these devices. Previous experimental work has shown the existence of fluctuations between low and high current density levels in PEFCs operated with wet hydrogen and dry air feed. The alternation between both performance states is accompanied by strong changes in the high frequency resistance, suggesting a cyclic hydration and dehydration of the membrane. This peculiar scenario is examined here considering liquid water distributions from neutron imaging and predictions from a 3D two-phase non-isothermal model. The results show that the hydration-dehydration cycles are triggered by the periodic condensation and shedding of liquid water at the anode inlet. The input of liquid water humidifies the anode channel and offsets the membrane dry-out induced by the dry air stream, thus leading to the high-performance state. When liquid water is flushed out of the anode channel, the dehydration process takes over, and the cell comes back to the low-performance state. The predicted amplitude of the current oscillations grows with decreasing hydrogen and increasing air flow rates, in agreement with previous experimental data.

  17. Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system.

    Science.gov (United States)

    Lillaney, Prasheel; Shin, Mihye; Hinshaw, Waldo; Bennett, N Robert; Pelc, Norbert; Fahrig, Rebecca

    2013-02-01

    Using hybrid x-ray∕MR (XMR) systems for image guidance during interventional procedures could enhance the diagnosis and treatment of neurologic, oncologic, cardiovascular, and other disorders. The authors propose a close proximity hybrid system design in which a C-arm fluoroscopy unit is placed immediately adjacent to the solenoid magnet of a MR system with a minimum distance of 1.2 m between the x-ray and MR imaging fields of view. Existing rotating anode x-ray tube designs fail within MR fringe field environments because the magnetic fields alter the electron trajectories in the x-ray tube and act as a brake on the induction motor, reducing the rotation speed of the anode. In this study the authors propose a novel motor design that avoids the anode rotation speed reduction. The proposed design replaces the permanent magnet stator found in brushed dc motors with the radial component of the MR fringe field. The x-ray tube is oriented such that the radial component of the MR fringe field is orthogonal to the cathode-anode axis. Using a feedback position sensor and the support bearings as electrical slip rings, the authors use electrical commutation to eliminate the need for mechanical brushes and commutators. A vacuum compatible prototype of the proposed motor design was assembled, and its performance was evaluated at various operating conditions. The prototype consisted of a 3.1 in. diameter anode rated at 300 kHU with a ceramic rotor that was 5.6 in. in length and had a 2.9 in. diameter. The material chosen for all ceramic components was MACOR, a machineable glass ceramic developed by Corning Inc. The approximate weight of the entire assembly was 1750 g. The maximum rotation speed, angular acceleration, and acceleration time of the motor design were investigated, as well as the dependence of these parameters on rotor angular offset, magnetic field strength, and field orientation. The resonance properties of the authors' assembly were also evaluated to determine

  18. Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Lillaney, Prasheel; Pelc, Norbert [Department of Radiology, Stanford University, Stanford, California 94305 and Department of Bioengineering, Stanford University, Stanford, California 94305 (United States); Shin Mihye [Department of Radiology, Stanford University, Stanford, California 94305 and Department of Mechanical Engineering, Stanford University, Stanford, California 94305 (United States); Hinshaw, Waldo; Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Bennett, N. Robert [Department of Radiology, Stanford University, Stanford, California 94305 and Qualcomm MEMS Technologies, San Jose, California 95134 (United States)

    2013-02-15

    Purpose: Using hybrid x-ray/MR (XMR) systems for image guidance during interventional procedures could enhance the diagnosis and treatment of neurologic, oncologic, cardiovascular, and other disorders. The authors propose a close proximity hybrid system design in which a C-arm fluoroscopy unit is placed immediately adjacent to the solenoid magnet of a MR system with a minimum distance of 1.2 m between the x-ray and MR imaging fields of view. Existing rotating anode x-ray tube designs fail within MR fringe field environments because the magnetic fields alter the electron trajectories in the x-ray tube and act as a brake on the induction motor, reducing the rotation speed of the anode. In this study the authors propose a novel motor design that avoids the anode rotation speed reduction. Methods: The proposed design replaces the permanent magnet stator found in brushed dc motors with the radial component of the MR fringe field. The x-ray tube is oriented such that the radial component of the MR fringe field is orthogonal to the cathode-anode axis. Using a feedback position sensor and the support bearings as electrical slip rings, the authors use electrical commutation to eliminate the need for mechanical brushes and commutators. A vacuum compatible prototype of the proposed motor design was assembled, and its performance was evaluated at various operating conditions. The prototype consisted of a 3.1 in. diameter anode rated at 300 kHU with a ceramic rotor that was 5.6 in. in length and had a 2.9 in. diameter. The material chosen for all ceramic components was MACOR, a machineable glass ceramic developed by Corning Inc. The approximate weight of the entire assembly was 1750 g. The maximum rotation speed, angular acceleration, and acceleration time of the motor design were investigated, as well as the dependence of these parameters on rotor angular offset, magnetic field strength, and field orientation. The resonance properties of the authors' assembly were also

  19. GHRSST Level 2P West Atlantic Regional Skin Sea Surface Temperature from the Geostationary Operational Environmental Satellites (GOES) Imager on the GOES-12 satellite (GDS version 1)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Geostationary Operational Environmental Satellites (GOES) operated by the United States National Oceanic and Atmospheric Administration (NOAA) support weather...

  20. GHRSST Level 2P Eastern Pacific Regional Skin Sea Surface Temperature from the Geostationary Operational Environmental Satellites (GOES) Imager on the GOES-11 satellite (GDS version 1)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Geostationary Operational Environmental Satellites (GOES) operated by the United States National Oceanic and Atmospheric Administration (NOAA) support weather...

  1. Image, Image, Image

    Science.gov (United States)

    Howell, Robert T.

    2004-01-01

    With all the talk today about accountability, budget cuts, and the closing of programs in public education, teachers cannot overlook the importance of image in the field of industrial technology. It is very easy for administrators to cut ITE (industrial technology education) programs to save school money--money they might shift to teaching the…

  2. Mapping crop based on phenological characteristics using time-series NDVI of operational land imager data in Tadla irrigated perimeter, Morocco

    Science.gov (United States)

    Ouzemou, Jamal-eddine; El Harti, Abderrazak; EL Moujahid, Ali; Bouch, Naima; El Ouazzani, Rabii; Lhissou, Rachid; Bachaoui, El Mostafa

    2015-10-01

    Morocco is a primarily arid to semi-arid country. These climatic conditions make irrigation an imperative and inevitable technique. Especially, agriculture has a paramount importance for the national economy. Retrieving of crops and their location as well as their spatial extent is useful information for agricultural planning and better management of irrigation water resource. Remote sensing technology was often used in management and agricultural research. Indeed, it's allows crops extraction and mapping based on phenological characteristics, as well as yield estimation. The study area of this work is the Tadla irrigated perimeter which is characterized by heterogeneous areas and extremely small size fields. Our principal objectives are: (1) the delimitation of the major crops for a good water management, (2) the insulation of sugar beet parcels for modeling its yields. To achieve the traced goals, we have used Landsat-8 OLI (Operational Land Imager) data pan-sharpened to 15 m. Spectral Angle Mapper (SAM) and Support Vector Machine (SVM) classifications were applied to the Normalized Difference Vegetation Index (NDVI) time-series of 10 periods. Classifications were calculated for a site of more than 124000 ha. This site was divided into two parts: the first part for selecting, training datasets and the second one for validating the classification results. The SVM and SAM methods classified the principal crops with overall accuracies of 85.27% and 57.17% respectively, and kappa coefficient of 80% and 43% respectively. The study showed the potential of using time-series OLI NDVI data for mapping different crops in irrigated, heterogeneous and undersized parcels in arid and semi-arid environment.

  3. Comparative Investigation of Ce3+ Doped Scintillators in a Wide Range of Photon Energies Covering X-ray CT, Nuclear Medicine and Megavoltage Radiation Therapy Portal Imaging Applications

    Science.gov (United States)

    Valais, Ioannis G.; Michail, Christos M.; David, Stratos L.; Liaparinos, Panagiotis F.; Fountos, George P.; Paschalis, Theodoros V.; Kandarakis, Ioannis S.; Panayiotakis, George S.

    2010-02-01

    The aim of the present work is to study the performance of scintillators currently used in PET and animal PET systems, under conditions met in radiation therapy and PET/CT imaging. The results of this study will be useful in applications where both CT and PET photons as well as megavoltage cone beam CT (MV CBCT) photons could be detected using a common detector unit. To this aim crystal samples of GSO, LSO, LYSO, LuYAP and YAP scintillators, doped with cerium (Ce+3) were examined under a wide energy range of photon energies. Evaluation was performed by determining the absolute luminescence efficiency (emitted light flux over incident X-ray exposure) in the energy range employed in X-ray CT, in Nuclear Medicine (70 keV up to 662 keV) and in radiotherapy 6 MV (approx. 2.0 MeV mean energy)-18 MV (approx. 4.5 MeV mean energy). Measurements were performed using an experimental set-up based on a photomultiplier coupled to a light integration sphere. The emission spectrum under X-ray excitation was measured, using an optical grating monochromator, to determine the spectral compatibility to optical photon detectors incorporated in medical imaging systems. Maximum absolute luminescence efficiency values were observed at 70 keV for YAP:Ce and LuYAP:Ce and at 140 keV for LSO:Ce, LYSO:Ce and GSO:Ce. Highest absolute efficiency between the scintillators examined was observed for LSO:Ce, followed by LYSO:Ce. The detector optical gain (DOG) exhibited a significant variation with the increase of energy between 70 keV to 2.0 MeV. All scintillators exhibited low compatibility when combined with GaAsP (G5645) photodetector.

  4. In situ quantification of the in-plane water content in the Nafion {sup registered} membrane of an operating polymer-electrolyte membrane fuel cell using {sup 1}H micro-magnetic resonance imaging experiments

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Mingtao; Feindel, Kirk W.; Bergens, Steven H.; Wasylishen, Roderick E. [Department of Chemistry, University of Alberta, E3-24 Gunning/Lemieux Chemistry Center, Edmonton, Alberta (Canada)

    2010-11-01

    Spatial, quantitative, and temporal information regarding the water content distribution in the transverse-plane between the catalyst layers of an operating polymer-electrolyte membrane fuel cell (PEMFC) is essential to develop a fundamental understanding of water dynamics in these systems. We report {sup 1}H micro-magnetic resonance imaging (MRI) experiments that measure the number of water molecules per SO{sub 3}H group, {lambda}, within a Nafion {sup registered} -117 membrane between the catalyst stamps of a membrane-electrode assembly, MEA. The measurements were made both ex situ, and inside a PEMFC operating on hydrogen and oxygen. The observed {sup 1}H MRI T{sub 2} relaxation time of water in the PEM was measured for several known values of {lambda}. The signal intensity of the images was then corrected for T{sub 2} weighting to yield proton density-weighted images, thereby establishing a calibration curve that correlates the {sup 1}H MRI density-weighted signal with {lambda}. Subsequently, the calibration curve was used with proton density weighted (i.e., T{sub 2}-corrected) signal intensities of transverse-plane {sup 1}H MRI images of water in the PEM between the catalyst stamps of an operating PEMFC to determine {lambda} under various operational conditions. For example, the steady state, transverse-plane {lambda} was 9 {+-} 1 for a PEMFC operating at {proportional_to}26.4 mW cm{sup -2} ({proportional_to}20.0 mA, {proportional_to}0.661 V, 20 C, flow rates of the dry H{sub 2}(g) and O{sub 2}(g) were 5.0 and 2.5 mL min{sup -1}, respectively). (author)

  5. Segmental analysis of cochlea on three-dimensional MR imaging and high-resolution CT. Application to pre-operative assessment of cochlear implant candidates

    International Nuclear Information System (INIS)

    Akiba, Hidenari; Himi, Tetsuo; Hareyama, Masato

    2002-01-01

    High-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) have recently become standard pre-operative examinations for cochlear implant candidates. HRCT can demonstrate ossification and narrowing of the cochlea, but subtle calcification or soft tissue obstruction may not be detected by this method alone, and so conventional T2 weighted image (T2WI) on MRI has been recommended to disclose them. In this study, segmental analyses of the cochlea were made on three-dimensional MRI (3DMRI) and HRCT in order to predict cochlear implant difficulties. The study involved 59 consecutive patients with bilateral profound sensorineural hearing loss who underwent MRI and HRCT from November 1992 to February 1998. Etiologies of deafness were meningogenic labyrinthitis (n=9), tympanogenic labyrinthitis (n=12), and others (n=38). Pulse sequence of heavy T2WI was steady state free precession and 3DMRI was reconstructed by maximum intensity projection method. HRCT was reconstructed by bone algorithm focusing on the temporal bone. For alternative segmental analysis, cochleas were anatomically divided into five parts and each of them was classified by three ranks of score depending on 3DMRI or HRCT findings. There was a close correlation by ranks between the total score of the five parts on 3DMRI and HRCT (rs=0.86, P<0.001), and a statistically significant difference was identified between causes of deafness in the total score on 3DMRI or HRCT (P<0.001, respectively). There was a significant difference in the score among the five parts on each examination (P<0.001, respectively), and abnormal findings were more frequent in the inferior horizontal part (IHP) of the basal turn. Of the 35 patients who underwent cochlear implantation, no one had ossification in the IHP on HRCT and only one patient had an obstacle to implantation. When no signal void in the IHP on 3DMRI and no ossification in the IHP on HRCT were assumed to be the criteria for candidacy for cochlear

  6. Intraoperative Radiation Therapy in Early Breast Cancer Using a Linear Accelerator Outside of the Operative Suite: An “Image-Guided” Approach

    International Nuclear Information System (INIS)

    Hanna, Samir Abdallah; Simões Dornellas de Barros, Alfredo Carlos; Martins de Andrade, Felipe Eduardo; Barbosa Bevilacqua, Jose Luiz; Morales Piato, José Roberto; Lopes Pelosi, Edilson; Martella, Eduardo; Fernandes da Silva, João Luis; Andrade Carvalho, Heloisa de

    2014-01-01

    Purpose: To present local control, complications, and cosmetic outcomes of intraoperative radiation therapy (IORT) for early breast cancer, as well as technical aspects related to the use of a nondedicated linear accelerator. Methods and Materials: This prospective trial began in May of 2004. Eligibility criteria were biopsy-proven breast-infiltrating ductal carcinoma, age >40 years, tumor <3 cm, and cN0. Exclusion criteria were in situ or lobular types, multicentricity, skin invasion, any contraindication for surgery and/or radiation therapy, sentinel lymph node involvement, metastasis, or another malignancy. Patients underwent classic quadrantectomy with intraoperative sentinel lymph node and margins evaluation. If both free, the patient was transferred from operative suite to linear accelerator room, and IORT was delivered (21 Gy). Primary endpoint: local recurrence (LR); secondary endpoints: toxicities and aesthetics. Quality assurance involved using a customized shield for chest wall protection, applying procedures to minimize infection caused by patient transportation, and using portal films to check collimator-shield alignment. Results: A total of 152 patients were included, with at least 1 year follow-up. Median age (range) was 58.3 (40-85.4) years, and median follow-up time was 50.7 (12-110.5) months. The likelihood of 5-year local recurrence was 3.7%. There were 3 deaths, 2 of which were cancer related. The Kaplan-Meier 5-year actuarial estimates of overall, disease-free, and local recurrence-free survivals were 97.8%, 92.5%, and 96.3%, respectively. The overall incidences of acute and late toxicities were 12.5% and 29.6%, respectively. Excellent, good, fair, and bad cosmetic results were observed in 76.9%, 15.8%, 4.3%, and 2.8% of patients, respectively. Most treatments were performed with a 5-cm collimator, and in 39.8% of the patients the electron-beam energy used was ≥12 MeV. All patients underwent portal film evaluation, and the shielding was

  7. Intraoperative Radiation Therapy in Early Breast Cancer Using a Linear Accelerator Outside of the Operative Suite: An “Image-Guided” Approach

    Energy Technology Data Exchange (ETDEWEB)

    Hanna, Samir Abdallah, E-mail: samir.hanna@hsl.org.br [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Simões Dornellas de Barros, Alfredo Carlos; Martins de Andrade, Felipe Eduardo; Barbosa Bevilacqua, Jose Luiz [Department of Mastology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Morales Piato, José Roberto [Department of Mastology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Department of Gynecology, Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo (Brazil); Lopes Pelosi, Edilson [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Martella, Eduardo [Department of Radiation Oncology, Hospital Perola Byington, Sao Paulo (Brazil); Fernandes da Silva, João Luis [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Andrade Carvalho, Heloisa de [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Department of Radiology and Oncology, Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo (Brazil)

    2014-08-01

    Purpose: To present local control, complications, and cosmetic outcomes of intraoperative radiation therapy (IORT) for early breast cancer, as well as technical aspects related to the use of a nondedicated linear accelerator. Methods and Materials: This prospective trial began in May of 2004. Eligibility criteria were biopsy-proven breast-infiltrating ductal carcinoma, age >40 years, tumor <3 cm, and cN0. Exclusion criteria were in situ or lobular types, multicentricity, skin invasion, any contraindication for surgery and/or radiation therapy, sentinel lymph node involvement, metastasis, or another malignancy. Patients underwent classic quadrantectomy with intraoperative sentinel lymph node and margins evaluation. If both free, the patient was transferred from operative suite to linear accelerator room, and IORT was delivered (21 Gy). Primary endpoint: local recurrence (LR); secondary endpoints: toxicities and aesthetics. Quality assurance involved using a customized shield for chest wall protection, applying procedures to minimize infection caused by patient transportation, and using portal films to check collimator-shield alignment. Results: A total of 152 patients were included, with at least 1 year follow-up. Median age (range) was 58.3 (40-85.4) years, and median follow-up time was 50.7 (12-110.5) months. The likelihood of 5-year local recurrence was 3.7%. There were 3 deaths, 2 of which were cancer related. The Kaplan-Meier 5-year actuarial estimates of overall, disease-free, and local recurrence-free survivals were 97.8%, 92.5%, and 96.3%, respectively. The overall incidences of acute and late toxicities were 12.5% and 29.6%, respectively. Excellent, good, fair, and bad cosmetic results were observed in 76.9%, 15.8%, 4.3%, and 2.8% of patients, respectively. Most treatments were performed with a 5-cm collimator, and in 39.8% of the patients the electron-beam energy used was ≥12 MeV. All patients underwent portal film evaluation, and the shielding was

  8. Introduction to computer image processing

    Science.gov (United States)

    Moik, J. G.

    1973-01-01

    Theoretical backgrounds and digital techniques for a class of image processing problems are presented. Image formation in the context of linear system theory, image evaluation, noise characteristics, mathematical operations on image and their implementation are discussed. Various techniques for image restoration and image enhancement are presented. Methods for object extraction and the problem of pictorial pattern recognition and classification are discussed.

  9. Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: a report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council.

    Science.gov (United States)

    Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith

    2012-05-01

    Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology "automatic dose rate and image quality" (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were

  10. Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

    Energy Technology Data Exchange (ETDEWEB)

    Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith [Henry Ford Health System, Detroit, Michigan 48202 (United States); Beth Israel Deaconess Medical Center, Boston, Massachusetts 02115 (United States); Columbia University Medical Center, New York, New York 10032 (United States); Shiga Medical Center for Children, Moriyama City, Shiga-Ken, Japan 524-0022 (Japan); University of Virginia Health Science Center, Charlottesville, Virginia 22908 (United States); Baystate Health Systems, Inc., Springfield, Massachusetts 01199 (United States); Columbia University Medical Center, New York, New York 10032 (United States); University of Texas M.D. Anderson Cancer Center, Houston, Texas 77030 (United States); Cincinnati Children' s Hospital Medical Center, Cincinnati, Ohio 45229 (United States)

    2012-05-15

    Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which

  11. Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

    International Nuclear Information System (INIS)

    Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith

    2012-01-01

    Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were

  12. Image compression of bone images

    International Nuclear Information System (INIS)

    Hayrapetian, A.; Kangarloo, H.; Chan, K.K.; Ho, B.; Huang, H.K.

    1989-01-01

    This paper reports a receiver operating characteristic (ROC) experiment conducted to compare the diagnostic performance of a compressed bone image with the original. The compression was done on custom hardware that implements an algorithm based on full-frame cosine transform. The compression ratio in this study is approximately 10:1, which was decided after a pilot experiment. The image set consisted of 45 hand images, including normal images and images containing osteomalacia and osteitis fibrosa. Each image was digitized with a laser film scanner to 2,048 x 2,048 x 8 bits. Six observers, all board-certified radiologists, participated in the experiment. For each ROC session, an independent ROC curve was constructed and the area under that curve calculated. The image set was randomized for each session, as was the order for viewing the original and reconstructed images. Analysis of variance was used to analyze the data and derive statistically significant results. The preliminary results indicate that the diagnostic quality of the reconstructed image is comparable to that of the original image

  13. The role of breast MR imaging in pre-operative determination of invasive disease for ductal carcinoma in situ diagnosed by needle biopsy

    International Nuclear Information System (INIS)

    Goto, Mariko; Yuen, Sachiko; Akazawa, Kentaro; Nishida, Kaori; Yamada, Kei; Konishi, Eiichi; Kajihara, Mariko; Shinkura, Nobuhiko

    2012-01-01

    To evaluate whether magnetic resonance (MR) imaging features can predict the presence of occult invasion in cases of biopsy-proven pure ductal carcinoma in situ (DCIS). We retrospectively reviewed 92 biopsy-proven pure DCIS in 92 women who underwent MR imaging. The following MR imaging findings were compared between confirmed DCIS and invasive breast cancer (IBC): lesion size, type, morphological and kinetic assessments by ACR BI-RADS MRI, and findings of fat-suppressed T2-weighted (FS-T2W) imaging. Sixty-eight of 92 (74%) were non-mass-like enhancements (NMLE) and 24 were mass lesions on MR imaging. Twenty-one of 68 (31%) NMLE and 13 of 24 (54%) mass lesions were confirmed as IBC. In NMLE lesions, large lesions (P = 0.007) and higher signal intensities (SI) on FS-T2W images (P = 0.032) were significantly associated with IBC. Lesion size remained a significant independent predictor of invasion in multivariate analysis (P = 0.032), and combined with FS-T2W SIs showed slightly higher observer performances (area under the curve, AUC, 0.71) than lesion size alone (AUC 0.68). There were no useful findings that enabled the differentiation of mass-type lesions. Breast MR imaging is potentially useful to predict the presence of occult invasion in biopsy-proven DCIS with NMLE. MR mammography permits more precise lesion assessment including ductal carcinoma in situ A correct diagnosis of occult invasion before treatment is important for clinicians This study showed the potential of MR mammography to diagnose occult invasion Treatment and/or aggressive biopsy can be given with greater confidence MR mammography can lead to more appropriate management of patients. (orig.)

  14. Image retrieval

    DEFF Research Database (Denmark)

    Ørnager, Susanne

    1997-01-01

    The paper touches upon indexing and retrieval for effective searches of digitized images. Different conceptions of what subject indexing means are described as a basis for defining an operational subject indexing strategy for images. The methodology is based on the art historian Erwin Panofsky......), special knowledge about image codes, and special knowledge about history of ideas. The semiologist Roland Barthes has established a semiology for pictorial expressions based on advertising photos. Barthes uses the concepts denotation/connotation where denotations can be explained as the sober expression...

  15. Introduction to digital image processing

    CERN Document Server

    Pratt, William K

    2013-01-01

    CONTINUOUS IMAGE CHARACTERIZATION Continuous Image Mathematical Characterization Image RepresentationTwo-Dimensional SystemsTwo-Dimensional Fourier TransformImage Stochastic CharacterizationPsychophysical Vision Properties Light PerceptionEye PhysiologyVisual PhenomenaMonochrome Vision ModelColor Vision ModelPhotometry and ColorimetryPhotometryColor MatchingColorimetry ConceptsColor SpacesDIGITAL IMAGE CHARACTERIZATION Image Sampling and Reconstruction Image Sampling and Reconstruction ConceptsMonochrome Image Sampling SystemsMonochrome Image Reconstruction SystemsColor Image Sampling SystemsImage QuantizationScalar QuantizationProcessing Quantized VariablesMonochrome and Color Image QuantizationDISCRETE TWO-DIMENSIONAL LINEAR PROCESSING Discrete Image Mathematical Characterization Vector-Space Image RepresentationGeneralized Two-Dimensional Linear OperatorImage Statistical CharacterizationImage Probability Density ModelsLinear Operator Statistical RepresentationSuperposition and ConvolutionFinite-Area Superp...

  16. Image processing with ImageJ

    NARCIS (Netherlands)

    Abramoff, M.D.; Magalhães, Paulo J.; Ram, Sunanda J.

    2004-01-01

    Wayne Rasband of NIH has created ImageJ, an open source Java-written program that is now at version 1.31 and is used for many imaging applications, including those that that span the gamut from skin analysis to neuroscience. ImageJ is in the public domain and runs on any operating system (OS).

  17. Classification, clinical findings and operative treatment of degenerative and posttraumatic shoulder disease What do we really need to know from an imaging report to establish a treatment strategy?

    International Nuclear Information System (INIS)

    Boenisch, U.; Lembcke, O.; Naumann, Th.

    2000-01-01

    Successful patient care involves interdisciplinary Cupertino. Images allow an interpretation of a static dimension, but may not be sufficient to develop a surgical treatment strategy, since many shoulder problems have its origin in a dynamic pathology. This article outlines dynamic clinical tests of shoulder pathology, classifies various degenerative and posttraumatic shoulder problems and stresses key facts an imaging report should include in order to plan surgery. This article conveys basic knowledge of those tests and the dynamic background of shoulder pathology. Basic surgical treatment principles are summarised briefly

  18. Satellite image collection optimization

    Science.gov (United States)

    Martin, William

    2002-09-01

    Imaging satellite systems represent a high capital cost. Optimizing the collection of images is critical for both satisfying customer orders and building a sustainable satellite operations business. We describe the functions of an operational, multivariable, time dynamic optimization system that maximizes the daily collection of satellite images. A graphical user interface allows the operator to quickly see the results of what if adjustments to an image collection plan. Used for both long range planning and daily collection scheduling of Space Imaging's IKONOS satellite, the satellite control and tasking (SCT) software allows collection commands to be altered up to 10 min before upload to the satellite.

  19. Union operation image processing of data cubes separately processed by different objective filters and its application to void analysis in an all-solid-state lithium-ion battery.

    Science.gov (United States)

    Yamamoto, Yuta; Iriyama, Yasutoshi; Muto, Shunsuke

    2016-04-01

    In this article, we propose a smart image-analysis method suitable for extracting target features with hierarchical dimension from original data. The method was applied to three-dimensional volume data of an all-solid lithium-ion battery obtained by the automated sequential sample milling and imaging process using a focused ion beam/scanning electron microscope to investigate the spatial configuration of voids inside the battery. To automatically fully extract the shape and location of the voids, three types of filters were consecutively applied: a median blur filter to extract relatively larger voids, a morphological opening operation filter for small dot-shaped voids and a morphological closing operation filter for small voids with concave contrasts. Three data cubes separately processed by the above-mentioned filters were integrated by a union operation to the final unified volume data, which confirmed the correct extraction of the voids over the entire dimension contained in the original data. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Radio- and VUV - Excited Luminescence of YAP:Ce, YAP:Pr and YAG:Pr

    Science.gov (United States)

    2001-01-01

    Pr 3+ ions.", Acta Physica Polonica A, 90 pp.407-10, 1996. 6. C. Pedrini, D. Bouttet, C. Dujardin, B. Moine, I. Dafinei, P. Lecoq, M. Koselja, K...34Spectroscopy and thermoluminescence of LuAIO 3:Ce" Acta Physica Polonica A,.90, pp.377-383, 1996 17. A.J. Wojtowicz, J. Glodo, W. Drozdowski, K.R. Przegietka...Malinowski, M.F. Joubert, B. Jacquier. "Simultaneous laser action at blue and orange wavelengths in YAG:Pr 3+ Physica Status Solidi A, 140, pp.K49-52, 1993 5

  1. Vortex Flow in the Right Atrium Surrogates Supraventricular Arrhythmia and Thrombus After Atriopulmonary Connection-Type Fontan Operation: Vortex Flow Analysis Using Conventional Cine Magnetic Resonance Imaging.

    Science.gov (United States)

    Shiina, Yumi; Inai, Kei; Takahashi, Tatsunori; Shimomiya, Yamato; Ishizaki, Umiko; Fukushima, Kenji; Nagao, Michinobu

    2018-02-01

    We developed a novel imaging technique, designated as vortex flow (VF) mapping, which presents a vortex flow visually on conventional two-dimensional (2D) cine MRI. Using it, we assessed circumferential VF patterns and influences on RA thrombus and supraventricular tachycardia (SVT) in AP connection-type Fontan circulation. Retrospectively, we enrolled 27 consecutive patients (25.1 ± 9.2 years) and 7 age-matched controls who underwent cardiac MRI. Conventional cine images acquired using a 1.5-Tesla scanner were scanned for axial and coronal cross section of the RA. We developed "vortex flow mapping" to demonstrate the ratio of the circumferential voxel movement at each phase to the total movement throughout a cardiac cycle towards the RA center. The maximum ratio was used as a magnitude of vortex flow (MVF%) in RA cine imaging. We also measured percentages of strong and weak VF areas (VFA%). Furthermore, in 10 out of 27, we compared VF between previous CMR (3.8 ± 1.5 years ago) and latest CMR. Of the patients, 15 had cardiovascular complications (Group A); 12 did not (Group B). A transaxial image showed that strong VFA% in Group A was significantly smaller than that in Group B or controls. A coronal view revealed that strong VFA% was also smaller, and weak VFA% was larger in Group A than in Group B or controls (P < 0.05, and P < 0.05). Maximum MVF% in Group A was significantly smaller than in other groups (P < 0.001). Univariate logistic analyses revealed weak VFA% on a coronal image, and serum total bilirubin level as factors affecting cardiovascular complications (Odds ratio 1.14 and 66.1, 95% CI 1.004-1.30 and 1.59-2755.6, P values < 0.05 and < 0.05, respectively). Compared to the previous CMR, smaller maximum VMF%, smaller strong VFA%, and larger weak VFA% were identified in the latest CMR. Circumferentially weak VFA% on a coronal image can be one surrogate marker of SVT and thrombus in AP connection-type Fontan circulation. This simple VF

  2. The contribution of magnetic resonance imaging of the larynx compared with that of computed tomography in the pretreatment assessment of laryngeal cancers based on a series of ninety operated cases

    International Nuclear Information System (INIS)

    Giron, J.; Joffre, P.; Serres-Cousine, O.; Castan, P.; Senac, J.P.

    1990-01-01

    The authors report a prospective and comparative study of the pre-operative staging of 90 laryngeal carcinomas by CT and MRI, with blind analysis of each examination. The radio-anatomic correlations and the inter-method correlations (CT versus MRI) are reported. According to the authors MRI seems to be the method of choice because of its capabilities in soft tissues differentiation and because of its multiplanar representation. The motion artefacts are resolved by the fast imaging technique and the spatial resolution is optimized by special surface coils [fr

  3. Mid-term follow-up of patients with transposition of the great arteries after atrial inversion operation using two- and three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Fogel, Mark A.; Weinberg, Paul M.; Hubbard, Anne

    2002-01-01

    Background: Older patients with transposition of the great arteries who have undergone an atrial inversion procedure (ATRIAL-INV) are difficult to image by echocardiography. The surgical baffles are spatially complex. Objective: To test the hypothesis that two- and three-dimensional MRI can elucidate the spatially complex anatomy in this patient population. Materials and methods; Twelve patients with ATRIAL-INV, ages 16±4.5 years, underwent routine T1-weighted spin-echo axial imaging to obtain a full cardiac volumetric data set. Postprocessing created three-dimensional shaded surface displays and allowed for multiplanar reconstruction. Routine transthoracic echocardiography was available on all patients. Results: Three-dimensional reconstruction enabled complete spatial conceptualization of the venous pathways, and allowed for precise localization of a narrowed region in the upper limb of the systemic venous pathway found in two patients. This was subsequently confirmed on angiography. Routine MRI was able to image the full extent of the venous pathways in all 12 patients. Routine transthoracic echocardiography was able to visualize proximal portions of the venous pathways in eight (67%), the distal upper limb in five (42%), and the distal lower limb in four (33%) patients, and it was able to visualize the outflow tracts in all patients. Conclusion: Three-dimensional reconstruction adds important spatial information, which can be especially important in stenotic regions. Routine MRI is superior to transthoracic echocardiography in delineation of the systemic and pulmonary venous pathway anatomy of ATRIAL-INV patients at mid-term follow-up. Although transesophageal echocardiography is an option, it is more invasive. (orig.)

  4. Focus on image sensors

    NARCIS (Netherlands)

    Jos Gunsing; Daniël Telgen; Johan van Althuis; Jaap van de Loosdrecht; Mark Stappers; Peter Klijn

    2013-01-01

    Robots need sensors to operate properly. Using a single image sensor, various aspects of a robot operating in its environment can be measured or monitored. Over the past few years, image sensors have improved a lot: frame rate and resolution have increased, while prices have fallen. As a result,

  5. Imaging-guided thoracoscopic resection of a ground-glass opacity lesion in a hybrid operating room equipped with a robotic C-arm CT system.

    Science.gov (United States)

    Hsieh, Chen-Ping; Hsieh, Ming-Ju; Fang, Hsin-Yueh; Chao, Yin-Kai

    2017-05-01

    The intraoperative identification of small pulmonary nodules through video-assisted thoracoscopic surgery remains challenging. Although preoperative CT-guided nodule localization is commonly used to detect tumors during video-assisted thoracoscopic surgery (VATS), this approach carries inherent risks. We report the case of a patient with stage I lung cancer presenting as an area of ground-glass opacity (GGO) in the right upper pulmonary lobe. He successfully underwent a single-stage, CT-guided localization and removal of the pulmonary nodule within a hybrid operating room (OR) equipped with a robotic C-arm.

  6. Spatial Operations

    Directory of Open Access Journals (Sweden)

    Anda VELICANU

    2010-09-01

    Full Text Available This paper contains a brief description of the most important operations that can be performed on spatial data such as spatial queries, create, update, insert, delete operations, conversions, operations on the map or analysis on grid cells. Each operation has a graphical example and some of them have code examples in Oracle and PostgreSQL.

  7. Operational amplifiers

    CERN Document Server

    Dostal, Jiri

    1993-01-01

    This book provides the reader with the practical knowledge necessary to select and use operational amplifier devices. It presents an extensive treatment of applications and a practically oriented, unified theory of operational circuits.Provides the reader with practical knowledge necessary to select and use operational amplifier devices. Presents an extensive treatment of applications and a practically oriented, unified theory of operational circuits

  8. Evolution of submarine eruptive activity during the 2011-2012 El Hierro event as documented by hydroacoustic images and remotely operated vehicle observations

    Science.gov (United States)

    Somoza, L.; González, F. J.; Barker, S. J.; Madureira, P.; Medialdea, T.; de Ignacio, C.; Lourenço, N.; León, R.; Vázquez, J. T.; Palomino, D.

    2017-08-01

    Submarine volcanic eruptions are frequent and important events, yet they are rarely observed. Here we relate bathymetric and hydroacoustic images from the 2011 to 2012 El Hierro eruption with surface observations and deposits imaged and sampled by ROV. As a result of the shallow submarine eruption, a new volcano named Tagoro grew from 375 to 89 m depth. The eruption consisted of two main phases of edifice construction intercalated with collapse events. Hydroacoustic images show that the eruptions ranged from explosive to effusive with variable plume types and resulting deposits, even over short time intervals. At the base of the edifice, ROV observations show large accumulations of lava balloons changing in size and type downslope, coinciding with the area where floating lava balloon fallout was observed. Peaks in eruption intensity during explosive phases generated vigorous bubbling at the surface, extensive ash, vesicular lapilli and formed high-density currents, which together with periods of edifice gravitational collapse, produced extensive deep volcaniclastic aprons. Secondary cones developed in the last stages and show evidence for effusive activity with lava ponds and lava flows that cover deposits of stacked lava balloons. Chaotic masses of heterometric boulders around the summit of the principal cone are related to progressive sealing of the vent with decreasing or variable magma supply. Hornitos represent the final eruptive activity with hydrothermal alteration and bacterial mats at the summit. Our study documents the distinct evolution of a submarine volcano and highlights the range of deposit types that may form and be rapidly destroyed in such eruptions.Plain Language SummaryToday and through most of geological history, the greatest number and volume of volcanic eruptions on Earth have occurred underwater. However, in comparison to subaerial eruption, little is known about submarine eruptive processes as they are dangerous to cruise it over

  9. Intra-operative Vector Flow Imaging Using Ultrasound of the Ascending Aorta among 40 Patients with Normal, Stenotic and Replaced Aortic Valves

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper

    2016-01-01

    Stenosis of the aortic valve gives rise to more complex blood flows with increased velocities. The angleindependent vector flow ultrasound technique transverse oscillation was employed intra-operatively on the ascending aorta of (I) 20 patients with a healthy aortic valve and 20 patients with aor...... replacement corrects some of these changes. Transverse oscillation may be useful for assessment of aortic stenosis and optimization of valve surgery. (E-mail: lindskov@gmail.com) 2016 World Federation for Ultrasound in Medicine & Biology...... with aortic stenosis before (IIa) and after (IIb) valve replacement. The results indicate that aortic stenosis increased flow complexity (p , 0.0001), induced systolic backflow (p , 0.003) and reduced systolic jet width (p , 0.0001). After valve replacement, the systolic backflow and jet width were normalized...

  10. Accuracy of magnetic resonance imaging in the pre-operative staging of rectal adenocarcinoma: Experience from a regional Australian cancer center.

    Science.gov (United States)

    White, Rohen; Ung, Kim Ann; Mathlum, Maitham

    2013-12-01

    Selection of the optimal treatment pathway in patients with rectal adenocarcinoma relies on accurate locoregional staging. This study aims to assess the accuracy of staging with magnetic resonance imaging (MRI) and in particular, its accuracy in differentiating patients with early stage disease from those with more advanced disease who benefit from a different treatment approach. Patients who were staged with MRI and received surgery as the first line of treatment for biopsy-proven adenocarcinoma of the rectum were identified. Comparison was made between the clinical stage on MRI and the pathological stage of the surgical specimen. The sensitivity, specificity and overall accuracy of MRI was assessed. In all, 58 eligible patients were identified. In 31% of patients, the extent of disease was underrepresented on preoperative MRI. Sensitivity, specificity and overall accuracy of anorectal MRI in detecting stage II/III disease status in this cohort was 59, 71 and 62%, respectively. MRI underestimated the pathological stage in many patients in this series who may have benefited from the addition of neoadjuvant radiotherapy to their management. This study supports further refinement of preoperative staging and demonstrates that impressive results from highly controlled settings may be difficult to reproduce in community practice. © 2012 Wiley Publishing Asia Pty Ltd.

  11. Medical imaging

    International Nuclear Information System (INIS)

    Elliott, Alex

    2005-01-01

    Diagnostic medical imaging is a fundamental part of the practice of modern medicine and is responsible for the expenditure of considerable amounts of capital and revenue monies in healthcare systems around the world. Much research and development work is carried out, both by commercial companies and the academic community. This paper reviews briefly each of the major diagnostic medical imaging techniques-X-ray (planar and CT), ultrasound, nuclear medicine (planar, SPECT and PET) and magnetic resonance. The technical challenges facing each are highlighted, with some of the most recent developments. In terms of the future, interventional/peri-operative imaging, the advancement of molecular medicine and gene therapy are identified as potential areas of expansion

  12. Averaging operations on matrices

    Indian Academy of Sciences (India)

    2014-07-03

    Jul 3, 2014 ... Role of Positive Definite Matrices. • Diffusion Tensor Imaging: 3 × 3 pd matrices model water flow at each voxel of brain scan. • Elasticity: 6 × 6 pd matrices model stress tensors. • Machine Learning: n × n pd matrices occur as kernel matrices. Tanvi Jain. Averaging operations on matrices ...

  13. Magnetic Resonance Imaging Patterns of Post-Operative Spinal Infection: Relationship between the Clinical Onset of Infection and the Infection Site.

    Science.gov (United States)

    Kim, Seon-Jeong; Lee, Sang Hoon; Chung, Hye Won; Lee, Min Hee; Shin, Myung Jin; Park, Seoung Woo

    2017-07-01

    To investigate the magnetic resonance imaging (MRI) findings and the patterns of postoperative spinal infection according to the passage of time. Institutional review board approval was obtained, and informed consent was not obtained for the retrospective review of patients' medical records. A total of 43 patients (27 men and 16 women; mean age, 64) diagnosed with postoperative spinal infection were included in this study. We retrospectively reviewed the MRI findings and the medical records and categorized the infection sites based on MRI, i.e., anterior, posterior, and both parts. The duration of the clinical onset from surgery was divided, i.e., acute (≤2 weeks), subacute (2-4 weeks), and late (>4 weeks). Postoperative spinal infection was involved in the posterior part in 31 (72%), anterior part in two (4.7%), and both parts in 10 patients (23.3%). Abscess or phlegmon in the back muscles and laminectomy site were the most common MRI findings. The number of patients with acute, subacute, and late clinical onset were 35, two, and six, respectively (mean, 33.4 days; range, 1-730 days). The mean duration of the clinical onset was 12 days in the posterior part, 15.2 days in both parts, and 456.5 days in the anterior part. Postoperative spinal infection usually occurred within four weeks in the posterior part and over time the infection was considered to spread into the anterior part. For the evaluation of postoperative spinal infection, the posterior surgical field was more important than the vertebral body or the disc space on MRI.

  14. Evaluation of the optimal diagnostic criteria for regional lymph node metastases of lung cancer on MR imaging by receiver operating characteristic curve

    International Nuclear Information System (INIS)

    Iwai, Naomichi; Yamaguchi, Yutaka

    1991-01-01

    MRI was performed in 78 primary lung cancer cases to evaluate the optimal diagnostic criteria for regional lymph node metastases. Receiver operating characteristic (ROC) curve analysis for 262 lymph nodes of the hilar and mediastinal regions showed that the optimal size criterion is 10 mm in the mean axis of nodal diameter. Employing this criterion, the diagnostic rates for hilar and mediastinal lymph nodes had a sensitivity of 75%, a specificity of 82%, and an overall accuracy of 79%. However, the diagnostic rates for subaortic, paraaortic, and hilar lymph nodes using the same criterion showed lower specificities than those for other nodes. It was suggested that evaluation by coronal section made the diagnosis for subaortic lymph nodes more precise. In the ROC curve analysis for each histologic type, it was thought that the optimal criterion for adenocarcinoma was 10 mm in the mean axis, and that the criteria for squamous cell carcinoma were 11 mm in the mean axis and 10 mm in the sort axis. (author)

  15. Validation of cell voltage and water content in a PEM (polymer electrolyte membrane) fuel cell model using neutron imaging for different operating conditions

    International Nuclear Information System (INIS)

    Salva, J. Antonio; Iranzo, Alfredo; Rosa, Felipe; Tapia, Elvira

    2016-01-01

    This work presents a one dimensional analytical model developed for a 50 cm"2 PEM (polymer electrolyte membrane) fuel cell with five-channel serpentine flow field. The different coupled physical phenomena such as electrochemistry, mass transfer of hydrogen, oxygen and water (two phases) together with heat transfer have been solved simultaneously. The innovation of this work is that the model has been validated with two different variables simultaneously and quantitatively in order to ensure the accuracy of the results. The selected variables are the cell voltage and the water content within the membrane MEA (Membrane Electrode Assembly) and GDL (gas diffusion layers) experimentally measured by means of neutron radiography. The results show a good agreement for a comprehensive set of different operating conditions of cell temperature, pressure, reactants relative humidity and cathode stoichiometry. The analytical model has a relative error less than 3.5% for the value of the cell voltage and the water content within the GDL + MEA for all experiments performed. This result presents a new standard of validation in the state of art of PEM fuel cell modeling where two variables are simultaneously and quantitatively validated with experimental results. The developed analytical model has been used in order to analyze the behavior of the PEM fuel cell under different values of relative humidity. - Highlights: • One dimensional analytical model has been developed for a PEM fuel cell. • The model is validated with two different variables simultaneously. • New standard of validation is proposed.

  16. An operational perspective of challenging statistical dogma while establishing a modern, secure distributed data management and imaging transport system: the Pediatric Brain Tumor Consortium phase I experience.

    Science.gov (United States)

    Onar, Arzu; Ramamurthy, Uma; Wallace, Dana; Boyett, James M

    2009-04-01

    The Pediatric Brain Tumor Consortium (PBTC) is a multidisciplinary cooperative research organization devoted to the study of correlative tumor biology and new therapies for primary central nervous system (CNS) tumors of childhood. The PBTC was created in 1999 to conduct early-phase studies in a rapid fashion in order to provide sound scientific foundation for the Children's Oncology Group to conduct definitive trials. The Operations and Biostatistics Center (OBC) of the PBTC is responsible for centrally administering study design and trial development, study conduct and monitoring, data collection and management as well as various regulatory and compliance processes. The phase I designs utilized for the consortium trials have accommodated challenges unique to pediatric trials such as body surface area (BSA)-based dosing in the absence of pediatric formulations of oral agents. Further during the past decade, the OBC has developed and implemented a state-of-the-art secure and efficient internet-based paperless distributed data management system. Additional web-based systems are also in place for tracking and distributing correlative study data as well as neuroimaging files. These systems enable effective communications among the members of the consortium and facilitate the conduct and timely reporting of multi-institutional early-phase clinical trials.

  17. Disadvantages of using the area under the receiver operating characteristic curve to assess imaging tests: A discussion and proposal for an alternative approach

    International Nuclear Information System (INIS)

    Halligan, Steve; Altman, Douglas G.; Mallett, Susan

    2015-01-01

    The objectives are to describe the disadvantages of the area under the receiver operating characteristic curve (ROC AUC) to measure diagnostic test performance and to propose an alternative based on net benefit. We use a narrative review supplemented by data from a study of computer-assisted detection for CT colonography. We identified problems with ROC AUC. Confidence scoring by readers was highly non-normal, and score distribution was bimodal. Consequently, ROC curves were highly extrapolated with AUC mostly dependent on areas without patient data. AUC depended on the method used for curve fitting. ROC AUC does not account for prevalence or different misclassification costs arising from false-negative and false-positive diagnoses. Change in ROC AUC has little direct clinical meaning for clinicians. An alternative analysis based on net benefit is proposed, based on the change in sensitivity and specificity at clinically relevant thresholds. Net benefit incorporates estimates of prevalence and misclassification costs, and it is clinically interpretable since it reflects changes in correct and incorrect diagnoses when a new diagnostic test is introduced. ROC AUC is most useful in the early stages of test assessment whereas methods based on net benefit are more useful to assess radiological tests where the clinical context is known. Net benefit is more useful for assessing clinical impact. (orig.)

  18. Pre-Operative Planning Using Real-Time Virtual Sonography, an MRI/Ultrasound Image Fusion Technique, for Breast-Conserving Surgery in Patients with Non-Mass Enhancement on Breast MRI: A Preliminary Study.

    Science.gov (United States)

    Ando, Takahito; Ito, Yukie; Ido, Mirai; Osawa, Manami; Kousaka, Junko; Mouri, Yukako; Fujii, Kimihito; Nakano, Shogo; Kimura, Junko; Ishiguchi, Tsuneo; Watanebe, Rie; Imai, Tsuneo; Fukutomi, Takashi

    2018-07-01

    The purpose of this retrospective study was to evaluate the effect of pre-operative planning using real-time virtual sonography (RVS), a magnetic resonance imaging (MRI)/ultrasound (US) image fusion technique on breast-conserving surgery (BCS) in patients with non-mass enhancement (NME) on breast MRI. Between 2011 and 2015, we enrolled 12 consecutive patients who had lesions with NME that exceeded the US hypo-echoic area, in which it was particularly difficult to evaluate the tumor margin. During pre-operative planning before breast-conserving surgery, RVS was used to delineate the enhancing area on the breast surface after additional supine breast MRI was performed. We analyzed both the surgical margin positivity rate and the re-operation rate. All NME lesions corresponded to the index cancer. In all patients, the diameter of the NME lesion was greater than that of the hypo-echoic lesion. The median diameters of the NME and hypo-echoic lesions were 24 mm (range: 12-39 mm) and 8.0 mm (range: 4.9-18 mm), respectively (p = 0.0002). After RVS-derived skin marking was performed on the surface of the affected breast, lumpectomy and quadrantectomy were conducted in 7 and 5 patients, respectively. The surgical margins were negative in 10 (83%) patients. Two patients with positive margins were found to have ductal carcinoma in situ in 1 duct each, 2.4 and 3.2 mm from the resection margin, respectively. None of the patients required additional resection. Although further prospective studies are required, the findings of our preliminary study suggest that it is very well possible that the use of RVS-derived skin marking during pre-operative planning for BCS in patients with NME would have resulted in surgical outcomes similar to or better than those obtained without the use of such marking. Copyright © 2018. Published by Elsevier Inc.

  19. Intraoperative radiation therapy in early breast cancer using a linear accelerator outside of the operative suite: an "image-guided" approach.

    Science.gov (United States)

    Hanna, Samir Abdallah; de Barros, Alfredo Carlos Simões Dornellas; de Andrade, Felipe Eduardo Martins; Bevilacqua, Jose Luiz Barbosa; Piato, José Roberto Morales; Pelosi, Edilson Lopes; Martella, Eduardo; da Silva, João Luis Fernandes; Carvalho, Heloisa de Andrade

    2014-08-01

    To present local control, complications, and cosmetic outcomes of intraoperative radiation therapy (IORT) for early breast cancer, as well as technical aspects related to the use of a nondedicated linear accelerator. This prospective trial began in May of 2004. Eligibility criteria were biopsy-proven breast-infiltrating ductal carcinoma, age >40 years, tumor linear accelerator room, and IORT was delivered (21 Gy). Primary endpoint: local recurrence (LR); secondary endpoints: toxicities and aesthetics. Quality assurance involved using a customized shield for chest wall protection, applying procedures to minimize infection caused by patient transportation, and using portal films to check collimator-shield alignment. A total of 152 patients were included, with at least 1 year follow-up. Median age (range) was 58.3 (40-85.4) years, and median follow-up time was 50.7 (12-110.5) months. The likelihood of 5-year local recurrence was 3.7%. There were 3 deaths, 2 of which were cancer related. The Kaplan-Meier 5-year actuarial estimates of overall, disease-free, and local recurrence-free survivals were 97.8%, 92.5%, and 96.3%, respectively. The overall incidences of acute and late toxicities were 12.5% and 29.6%, respectively. Excellent, good, fair, and bad cosmetic results were observed in 76.9%, 15.8%, 4.3%, and 2.8% of patients, respectively. Most treatments were performed with a 5-cm collimator, and in 39.8% of the patients the electron-beam energy used was ≥12 MeV. All patients underwent portal film evaluation, and the shielding was repositioned in 39.9% of cases. No infection or anesthesia complications were observed. Local control with IORT was adequate, with low complication rates and good cosmetic outcomes. More than one-third of patients benefited from the "image-guidance" approach, and almost 40% benefited from the option of higher electron beam energies. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Wide Angle Imaging Lidar (WAIL): Theory of Operation and Results from Cross-Platform Validation at the ARM Southern Great Plains Site

    Science.gov (United States)

    Polonsky, I. N.; Davis, A. B.; Love, S. P.

    2004-05-01

    WAIL was designed to determine physical and geometrical characteristics of optically thick clouds using the off-beam component of the lidar return that can be accurately modeled within the 3D photon diffusion approximation. The theory shows that the WAIL signal depends not only on the cloud optical characteristics (phase function, extinction and scattering coefficients) but also on the outer thickness of the cloud layer. This makes it possible to estimate the mean optical and geometrical thicknesses of the cloud. The comparison with Monte Carlo simulation demonstrates the high accuracy of the diffusion approximation for moderately to very dense clouds. During operation WAIL is able to collect a complete data set from a cloud every few minutes, with averaging over horizontal scale of a kilometer or so. In order to validate WAIL's ability to deliver cloud properties, the LANL instrument was deployed as a part of the THickness from Off-beam Returns (THOR) validation IOP. The goal was to probe clouds above the SGP CART site at night in March 2002 from below (WAIL and ARM instruments) and from NASA's P3 aircraft (carrying THOR, the GSFC counterpart of WAIL) flying above the clouds. The permanent cloud instruments we used to compare with the results obtained from WAIL were ARM's laser ceilometer, micro-pulse lidar (MPL), millimeter-wavelength cloud radar (MMCR), and micro-wave radiometer (MWR). The comparison shows that, in spite of an unusually low cloud ceiling, an unfavorable observation condition for WAIL's present configuration, cloud properties obtained from the new instrument are in good agreement with their counterparts obtained by other instruments. So WAIL can duplicate, at least for single-layer clouds, the cloud products of the MWR and MMCR together. But WAIL does this with green laser light, which is far more representative than microwaves of photon transport processes at work in the climate system.

  1. European Space Imaging & Skybox Imaging

    International Nuclear Information System (INIS)

    Clark, J.; Schichor, P.

    2015-01-01

    Skybox and European Space Imaging have partnered to bring timely, Very High-Resolution imagery to customers in Europe and North Africa. Leveraging Silicon Valley ingenuity and world-class aerospace expertise, Skybox designs, builds, and operates a fleet of imaging satellites. With two satellites currently on-orbit, Skybox is quickly advancing towards a planned constellation of 24+ satellites with the potential for daily or sub-daily imaging at 70-90 cm resolution. With consistent, high-resolution imagery and video, European customers can monitor the dynamic units of human activity - cars, trucks, shipping containers, ships, aircraft, etc. - and derive valuable insights about the global economy. With multiple imaging opportunities per day, the Skybox constellation provides unprecedented access to imagery and information about critical targets that require rapid analysis. Skybox's unique capability to deliver high-definition video from space enables European customers to monitor a network of globally distributed assets with full-motion snapshots, without the need to deploy an aircraft or field team. The movement captured in these 30-90 second video windows yield unique insights that improve operational decisions. Skybox and EUSI are excited to offer a unique data source that can drive a better understanding of our world through supply chain monitoring, natural resource management, infrastructure monitoring, and crisis response. (author)

  2. WE-AB-BRA-07: Operating Room Quality Assurance (ORQA) for Spine Surgery Using Known-Component 3D-2D Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Uneri, A; De Silva, T; Goerres, J; Jacobson, M; Ketcha, M; Reaungamornrat, S; Siewerdsen, J [Johns Hopkins University, Baltimore, MD (United States); Kleinszig, G [Siemens Healthcare, Erlangen, Bayern (Germany); Vogt, S [Siemens Healthcare, Malvern, PA (United States); Khanna, A [Johns Hopkins Health Care and Surgery Center, Bethesda, MD (United States); Wolinsky, J [The Johns Hopkins Hospital, Baltimore, MD (United States)

    2016-06-15

    Purpose: Intraoperative x-ray radiography/fluoroscopy is commonly used to qualitatively assess delivery of surgical devices (e.g., spine pedicle screws) but can fail to reliably detect suboptimal placement (e.g., breach of adjacent critical structures). We present a method wherein prior knowledge of the patient and surgical components is leveraged to match preoperative CT and intraoperative radiographs for quantitative assessment of 3D pose. The method presents a new means of operating room quantitative quality assurance (ORQA) that could improve quality and safety, and reduce the frequency of revision surgeries. Methods: The algorithm (known-component registration, KC-Reg) uses patient-specific preoperative CT and parametrically defined surgical component models within a robust 3D-2D registration method to iteratively optimize gradient similarity using the covariance matrix adaptation evolution strategy. Advances from previous work address key challenges to clinical translation: i) absolving the need for offline geometric calibration of the C-arm; and ii) solving multiple component bodies simultaneously, thereby allowing QA in a single step (e.g., spinal construct with 4–20 screws), rather than sequential QA of each component. Performance was tested in a spine phantom with 10 pedicle screws, and first results from clinical studies are reported. Results: Phantom experiments demonstrated median target registration error (TRE) of (1.0±0.3) mm at the screw tip and (0.7°±0.4°) in angulation. The simultaneous multi-body registration approach improved TRE from the previous (sequential) method by 42%, reduced outliers, and fits into the natural workflow. Initial application of KC-Reg in clinical data shows TRE of (2.5±4.5) mm and (4.7°±0.5°). Conclusion: The KC-Reg algorithm offers a potentially valuable method for quantitative QA of the surgical product, using radiographic systems that are already within the surgical arsenal. For spine surgery, the method

  3. WE-AB-BRA-07: Operating Room Quality Assurance (ORQA) for Spine Surgery Using Known-Component 3D-2D Image Registration

    International Nuclear Information System (INIS)

    Uneri, A; De Silva, T; Goerres, J; Jacobson, M; Ketcha, M; Reaungamornrat, S; Siewerdsen, J; Kleinszig, G; Vogt, S; Khanna, A; Wolinsky, J

    2016-01-01

    Purpose: Intraoperative x-ray radiography/fluoroscopy is commonly used to qualitatively assess delivery of surgical devices (e.g., spine pedicle screws) but can fail to reliably detect suboptimal placement (e.g., breach of adjacent critical structures). We present a method wherein prior knowledge of the patient and surgical components is leveraged to match preoperative CT and intraoperative radiographs for quantitative assessment of 3D pose. The method presents a new means of operating room quantitative quality assurance (ORQA) that could improve quality and safety, and reduce the frequency of revision surgeries. Methods: The algorithm (known-component registration, KC-Reg) uses patient-specific preoperative CT and parametrically defined surgical component models within a robust 3D-2D registration method to iteratively optimize gradient similarity using the covariance matrix adaptation evolution strategy. Advances from previous work address key challenges to clinical translation: i) absolving the need for offline geometric calibration of the C-arm; and ii) solving multiple component bodies simultaneously, thereby allowing QA in a single step (e.g., spinal construct with 4–20 screws), rather than sequential QA of each component. Performance was tested in a spine phantom with 10 pedicle screws, and first results from clinical studies are reported. Results: Phantom experiments demonstrated median target registration error (TRE) of (1.0±0.3) mm at the screw tip and (0.7°±0.4°) in angulation. The simultaneous multi-body registration approach improved TRE from the previous (sequential) method by 42%, reduced outliers, and fits into the natural workflow. Initial application of KC-Reg in clinical data shows TRE of (2.5±4.5) mm and (4.7°±0.5°). Conclusion: The KC-Reg algorithm offers a potentially valuable method for quantitative QA of the surgical product, using radiographic systems that are already within the surgical arsenal. For spine surgery, the method

  4. Operating systems

    CERN Document Server

    Tsichritzis, Dionysios C; Rheinboldt, Werner

    1974-01-01

    Operating Systems deals with the fundamental concepts and principles that govern the behavior of operating systems. Many issues regarding the structure of operating systems, including the problems of managing processes, processors, and memory, are examined. Various aspects of operating systems are also discussed, from input-output and files to security, protection, reliability, design methods, performance evaluation, and implementation methods.Comprised of 10 chapters, this volume begins with an overview of what constitutes an operating system, followed by a discussion on the definition and pr

  5. Operational calculus

    CERN Document Server

    Boehme, Thomas K

    1987-01-01

    Operational Calculus, Volume II is a methodical presentation of operational calculus. An outline of the general theory of linear differential equations with constant coefficients is presented. Integral operational calculus and advanced topics in operational calculus, including locally integrable functions and convergence in the space of operators, are also discussed. Formulas and tables are included.Comprised of four sections, this volume begins with a discussion on the general theory of linear differential equations with constant coefficients, focusing on such topics as homogeneous and non-ho

  6. Magnetic resonance imaging and computed tomography in the assessment of mandibular invasion by squamous cell carcinoma of the oral cavity. Influence on surgical management and post-operative course.

    Science.gov (United States)

    Farrow, E S; Boulanger, T; Wojcik, T; Lemaire, A-S; Raoul, G; Julieron, M

    2016-11-01

    Preoperative evaluation of the bone for invasion by oral cavity squamous cell carcinoma remains challenging. The aim of our study was to compare the accuracy of MRI and CT in detecting mandibular invasion by oral squamous cell carcinoma of the oral cavity, with histologic results as the reference standard, and to assess the influence on surgical management and post-operative course. Patients who were clinically suspected of having bone invasion from oral cavity carcinoma were retrospectively included. A single senior radiologist reviewed MRI images and CT-scans, independently, for the presence or absence of mandibular invasion. The different surgical procedures were compared in terms of length of hospital stay and occurrence of surgical complications. Histological mandibular invasion occurred in 9 of 35 patients (25.7%). None of the preoperative imaging tests failed to detect bone invasion which resulted in a sensitivity of 100% for both MRI and CT. CT had slightly higher specificity than MRI (61.9% and 57.1% respectively) in predicting bone invasion, but no statistically significant difference was found (P=0.32). Specificity of CT and MRI was higher in the edentulous group (75% and 625% respectively) than in the dentate group (53.8% both), although no statistically significant difference was found. The length of hospital stay was increased in the segmental resection group (25±14.5 days) compared to the marginal resection group (13±4.6 days; P=0.004) and to the hemimandibulectomy group (15±7.2 days; P=0.014). Occurrence of post-operative complications, across all categories, was increased in the segmental resection group (70%, n=7/10; P=0.006) compared to the marginal resection group (8.3%, n=1/12) and to the hemimandibulectomy group (23.1%, n=3/13; P=0.04). MRI and CT being equivalent in detecting mandibular invasion, we suggest MRI as single imaging technique in the preoperative assessment of oral cavity SCC. Specificity could be increased if combined with

  7. Study of the operational parameters of crops turbine sprayer (turbo liner on spray quality and diameter of droplets, using image processing

    Directory of Open Access Journals (Sweden)

    F Behzadi Pour

    2017-05-01

    median numerical diameter (NMD and spraying quality indicator were calculated. A Spectrophotometry device at the wavelength of 427 nm, Image J and sas 9.2 software were used for measurement. This research was carried out in accordance with the calendar crop canola spraying in field conditions and the weather was calm that the wind speed was 0- 2.5 km hr-1, relative humidity was 29.7% - 32.5% and air temperature was 18.8˚C – 20.7˚C. Results and Discussion According to the results sprayer pressure, fan speed and forward speed were shown significantly different (P≤0.01 on the volume diameter of 50% (DV50 and median numerical diameter (NMD. The effect of spraying pressure on distributing quality indicator was shown significant (P ≤ 0.01, but the fan and forward speed did not shown any significant effect. Mean comparison of the interaction of pressure and forward speed on the spray quality index and the number median diameter were shown significant (P ≤ 0.01, but they did not shown any significant effect on the volume diameter of 50% (DV50. With increasing spraying pressure and fan speed, the droplet size, volume diameter of 50% (DV50 at 72% and numerical median diameter (NMD at 69% and distributing quality indicator at 46% were decreased that were corresponded with the result of Czaczyk et al. (2012, Peyman et al. (2011, Nuyttens et al. (2009 and Landers and Farooq (2004. With increasing spraying pressure and forward speed, the droplet size, numerical median diameter (NMD at 63% and distributing quality indicator at 35% were decreased that these resulted were corresponded with the results of Naseri et al. (2007 and Dorr et al. (2013. Conclusions With increasing spraying pressure, fan and forward speed, the droplet size, volume diameter of 50% (DV50 and numerical median diameter (NMD were decreased. Therefore, spraying quality indicator was decreased. The maximum pressure (35 bars, maximum fan speed (2430 rpm and maximum forward speed (13.5 km hr-1 were able to

  8. Geometric Operators on Boolean Functions

    DEFF Research Database (Denmark)

    Frisvad, Jeppe Revall; Falster, Peter

    In truth-functional propositional logic, any propositional formula represents a Boolean function (according to some valuation of the formula). We describe operators based on Decartes' concept of constructing coordinate systems, for translation of a propositional formula to the image of a Boolean...... function. With this image of a Boolean function corresponding to a propositional formula, we prove that the orthogonal projection operator leads to a theorem describing all rules of inference in propositional reasoning. In other words, we can capture all kinds of inference in propositional logic by means...... of a few geometric operators working on the images of Boolean functions. The operators we describe, arise from the niche area of array-based logic and have previously been tightly bound to an array-based representation of Boolean functions. We redefine the operators in an abstract form to make them...

  9. Spacecraft operations

    CERN Document Server

    Sellmaier, Florian; Schmidhuber, Michael

    2015-01-01

    The book describes the basic concepts of spaceflight operations, for both, human and unmanned missions. The basic subsystems of a space vehicle are explained in dedicated chapters, the relationship of spacecraft design and the very unique space environment are laid out. Flight dynamics are taught as well as ground segment requirements. Mission operations are divided into preparation including management aspects, execution and planning. Deep space missions and space robotic operations are included as special cases. The book is based on a course held at the German Space Operation Center (GSOC).

  10. Digital image processing an algorithmic approach with Matlab

    CERN Document Server

    Qidwai, Uvais

    2009-01-01

    Introduction to Image Processing and the MATLAB EnvironmentIntroduction Digital Image Definitions: Theoretical Account Image Properties MATLAB Algorithmic Account MATLAB CodeImage Acquisition, Types, and File I/OImage Acquisition Image Types and File I/O Basics of Color Images Other Color Spaces Algorithmic Account MATLAB CodeImage ArithmeticIntroduction Operator Basics Theoretical TreatmentAlgorithmic Treatment Coding ExamplesAffine and Logical Operations, Distortions, and Noise in ImagesIntroduction Affine Operations Logical Operators Noise in Images Distortions in ImagesAlgorithmic Account

  11. Terahertz composite imaging method

    Institute of Scientific and Technical Information of China (English)

    QIAO Xiaoli; REN Jiaojiao; ZHANG Dandan; CAO Guohua; LI Lijuan; ZHANG Xinming

    2017-01-01

    In order to improve the imaging quality of terahertz(THz) spectroscopy, Terahertz Composite Imaging Method(TCIM) is proposed. The traditional methods of improving THz spectroscopy image quality are mainly from the aspects of de-noising and image enhancement. TCIM breaks through this limitation. A set of images, reconstructed in a single data collection, can be utilized to construct two kinds of composite images. One algorithm, called Function Superposition Imaging Algorithm(FSIA), is to construct a new gray image utilizing multiple gray images through a certain function. The features of the Region Of Interest (ROI) are more obvious after operating, and it has capability of merging ROIs in multiple images. The other, called Multi-characteristics Pseudo-color Imaging Algorithm(McPcIA), is to construct a pseudo-color image by combining multiple reconstructed gray images in a single data collection. The features of ROI are enhanced by color differences. Two algorithms can not only improve the contrast of ROIs, but also increase the amount of information resulting in analysis convenience. The experimental results show that TCIM is a simple and effective tool for THz spectroscopy image analysis.

  12. Operator substitution

    NARCIS (Netherlands)

    Hautus, M.L.J.

    1994-01-01

    Substitution of an operator into an operator-valued map is defined and studied. A Bezout-type remainder theorem is used to derive a number of results. The tensor map is used to formulate solvability conditions for linear matrix equations. Some applications to system theory are given, in particular

  13. Operation amplifier

    NARCIS (Netherlands)

    Tetsuya, Saito; Nauta, Bram

    2008-01-01

    To provide an operation amplifier which improves power source voltage removal ratios while assuring phase compensation characteristics, and therefore can be realized with a small-scale circuit and low power consumption. SOLUTION: The operation amplifier comprises: a differential amplifier circuit 1;

  14. Operation Amplifier

    NARCIS (Netherlands)

    Tetsuya, Saito; Nauta, Bram

    2011-01-01

    PROBLEM TO BE SOLVED: To provide an operation amplifier which improves power source voltage removal ratios while assuring phase compensation characteristics, and therefore can be realized with a small-scale circuit and low power consumption. SOLUTION: The operation amplifier comprises: a

  15. Operation Amplifier

    NARCIS (Netherlands)

    Tetsuya, S.; Nauta, Bram

    2007-01-01

    PROBLEM TO BE SOLVED: To provide an operation amplifier which improves power source voltage removal ratios while assuring phase compensation characteristics, and therefore can be realized with a small-scale circuit and low power consumption. ; SOLUTION: The operation amplifier comprises: a

  16. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Operations of the SuperHILAC, the Bevatron/Bevalac, and the 184-inch Synchrocyclotron during the period from October 1977 to September 1978 are discussed. These include ion source development, accelerator facilities, the Heavy Ion Spectrometer System, and Bevelac biomedical operations

  17. Hanaro operation

    International Nuclear Information System (INIS)

    Lee, Ji Bok; Jeon, Byung Jin; Kwack, Byung Ho

    1997-01-01

    HANARO was configurated its first operating core in 1995. Long term operation test was conducted up to 3-1 cycle during 1996, in order to investigate the reactor characteristics due to fuel depletion and additional fuel loading. Now HANARO has accumulated 168.4 days of total operation time and 2,687.5 MWD of total thermal output. Reactor analysis, producing operation datum and its validation with test, periodic inspection and maintenance of the facility are continuously conducted for safe operation of the HANARO. Conducted the verification tests for installed utilization facilities, and successfully performed the radiation emergency drill. The shutdown report of TRIGA Mark II and III was submitted to MOST, and decommissioning will be started from 1997. (author). 70 tabs., 50 figs., 27 refs

  18. Image Filtering with Boolean and Statistical Operators.

    Science.gov (United States)

    1983-12-01

    S3(2) COMPLEX AMAT(256, 4). BMAT (256. 4). CMAT(256. 4) CALL IOF(3. MAIN. AFLNM. DFLNI, CFLNM. MS., 82, S3) CALL OPEN(1.AFLNM* 1.IER) CALL CHECKC!ER...RDBLK(2. 6164. MAT. 16, IER) CALL CHECK(IER) DO I K-1. 4 DO I J-1.256 CMAT(J. K)-AMAT(J. K)’. BMAT (J. K) I CONTINUE S CALL WRBLK(3. 164!. CMAT. 16. IER

  19. Reactor operation

    CERN Document Server

    Shaw, J

    2013-01-01

    Reactor Operation covers the theoretical aspects and design information of nuclear reactors. This book is composed of nine chapters that also consider their control, calibration, and experimentation.The opening chapters present the general problems of reactor operation and the principles of reactor control and operation. The succeeding chapters deal with the instrumentation, start-up, pre-commissioning, and physical experiments of nuclear reactors. The remaining chapters are devoted to the control rod calibrations and temperature coefficient measurements in the reactor. These chapters also exp

  20. Operator programs and operator processes

    NARCIS (Netherlands)

    Bergstra, J.A.; Walters, P.

    2003-01-01

    We define a notion of program which is not a computer program but an operator program: a detailed description of actions performed and decisions taken by a human operator (computer user) performing a task to achieve a goal in a simple setting consisting of that user, one or more computers and a

  1. Operator theory

    CERN Document Server

    2015-01-01

    A one-sentence definition of operator theory could be: The study of (linear) continuous operations between topological vector spaces, these being in general (but not exclusively) Fréchet, Banach, or Hilbert spaces (or their duals). Operator theory is thus a very wide field, with numerous facets, both applied and theoretical. There are deep connections with complex analysis, functional analysis, mathematical physics, and electrical engineering, to name a few. Fascinating new applications and directions regularly appear, such as operator spaces, free probability, and applications to Clifford analysis. In our choice of the sections, we tried to reflect this diversity. This is a dynamic ongoing project, and more sections are planned, to complete the picture. We hope you enjoy the reading, and profit from this endeavor.

  2. Operation Starvation

    National Research Council Canada - National Science Library

    Mason, Gerald

    2002-01-01

    More than 1,250,000 tons of shipping was sunk or damaged in the last five months of World War II when Twenty-first Bomber Command executed an aerial mining campaign against Japan known as Operation STARVATION...

  3. Peace Operations

    National Research Council Canada - National Science Library

    Proks, Josef

    2000-01-01

    Peace operations are more and more important in the contemporary world. The end of the Cold War increased not only possibilities of solving disputes by the international community but also by the number and diversity of threats and issues...

  4. Operator training

    International Nuclear Information System (INIS)

    Wirstad, J.

    1983-12-01

    The traditional operator job is changing, which among other things has generated a need for better job training. Surprisingly increased process automation has lead to increased operator qualifications, i.e. basic job training but also up-date and rehearsal training within certain fixed intervals. There are several, similar models for instructional system development available in the literature. One model which is of special interest integrates Operator Training development and Man-Machine Interfaces development. The extent to which Systematic Operator Training has been implemented varies with branches and companies. The nuclear power branch is given as an example in the report. This branch probably represents something better than the average among the process industries.(author)

  5. Operative Links

    DEFF Research Database (Denmark)

    Wistoft, Karen; Højlund, Holger

    2012-01-01

    educational goals, learning content, or value clarification. Health pedagogy is often a matter of retrospective rationalization rather than the starting point of planning. Health and risk behaviour approaches override health educational approaches. Conclusions: Operational links between health education......, health professionalism, and management strategies pose the foremost challenge. Operational links indicates cooperative levels that facilitate a creative and innovative effort across traditional professional boundaries. It is proposed that such links are supported by network structures, shared semantics...

  6. GHRSST Level 2P Western Atlantic Regional Skin Sea Surface Temperature from the Geostationary Operational Environmental Satellites (GOES) Imager on the GOES-13 satellite (GDS versions 1 and 2)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Geostationary Operational Environmental Satellites (GOES) operated by the United States National Oceanic and Atmospheric Administration (NOAA) support weather...

  7. GHRSST Level 2P Central Pacific Regional Skin Sea Surface Temperature from the Geostationary Operational Environmental Satellites (GOES) Imager on the GOES-15 satellite (GDS versions 1 and 2)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Geostationary Operational Environmental Satellites (GOES) operated by the United States National Oceanic and Atmospheric Administration (NOAA) support weather...

  8. New operator's console recorder

    International Nuclear Information System (INIS)

    Anon.

    2009-01-01

    This article described a software module that automatically records images being shown on multiple HMI or SCADA operator's displays. Videos used for monitoring activities at industrial plants can be combined with the operator console videos and data from a process historian. This enables engineers, analysts or investigators to see what is occurring in the plant, what the operator is seeing on the HMI screen, and all relevant real-time data from an event. In the case of a leak at a pumping station, investigators could watch plant video taken at a remote site showing fuel oil creeping across the floor, real-time data being acquired from pumps, valves and the receiving tank while the leak is occurring. The video shows the operator's HMI screen as well as the alarm screen that signifies the leak detection. The Longwatch Operator's Console Recorder and Video Historian are used together to acquire data about actual plant plant management because they show everything that happens during an event. The Console Recorder automatically retrieves and replays operator displays by clicking on a time-based alarm or system message. Play back of video feed is a valuable tool for training and analysis purposes, and can help mitigate insurance and regulatory issues by eliminating uncertainty and conjecture. 1 fig.

  9. Applied Operations Research: Operator's Assistant

    Science.gov (United States)

    Cole, Stuart K.

    2015-01-01

    NASA operates high value critical equipment (HVCE) that requires trouble shooting, periodic maintenance and continued monitoring by Operations staff. The complexity HVCE and information required to maintain and trouble shoot HVCE to assure continued mission success as paper is voluminous. Training on new HVCE is commensurate with the need for equipment maintenance. LaRC Research Directorate has undertaken a proactive research to support Operations staff by initiation of the development and prototyping an electronic computer based portable maintenance aid (Operator's Assistant). This research established a goal with multiple objectives and a working prototype was developed. The research identified affordable solutions; constraints; demonstrated use of commercial off the shelf software; use of the US Coast Guard maintenance solution; NASA Procedure Representation Language; and the identification of computer system strategies; where these demonstrations and capabilities support the Operator, and maintenance. The results revealed validation against measures of effectiveness and overall proved a substantial training and capability sustainment tool. The research indicated that the OA could be deployed operationally at the LaRC Compressor Station with an expectation of satisfactorily results and to obtain additional lessons learned prior to deployment at other LaRC Research Directorate Facilities. The research revealed projected cost and time savings.

  10. Operating experience

    International Nuclear Information System (INIS)

    McRae, L.P.; Six, D.E.

    1991-01-01

    In 1987, Westinghouse Hanford Company began operating a first-generation integrated safeguards system in the Plutonium Finishing Plant storage vaults. This Vault Safety and Inventory System is designed to integrate data into a computer-based nuclear material inventory monitoring system. The system gathers, in real time, measured physical parameters that generate nuclear material inventory status data for thousands of stored items and sends tailored report to the appropriate users. These data include canister temperature an bulge data reported to Plant Operations and Material Control and Accountability personnel, item presence and identification data reported to Material Control and Accountability personnel, and unauthorized item movement data reported to Security response forces and Material Control and Accountability personnel. The Westinghouse Hanford Company's experience and operational benefits in using this system for reduce radiation exposure, increase protection against insider threat, and real-time inventory control are discussed in this paper

  11. Operator companion

    International Nuclear Information System (INIS)

    Natalizio, A.; Anderson, J.W.D.; Sills, H.E.

    1988-01-01

    Abundant, cheap computing power has provided industry with a far greater opportunity than was available one or two decades ago to automate industrial processes and to improve the man-machine interface. Exciting innovations in knowledge representation methods arising from artificial intelligence research pave the way for advanced support systems for assisting plant operators. AECL has recognized the importance of knowledge based system technology, particularly expert systems, in the achievement of this objective and also, as a strategic technology to be fully exploited in the next generation of CANDU reactors. Operator Companion, an expert system intended to diagnose plant faults and advise the operator on appropriate restoring or corrective actions, is a major undertaking which is receiving support within the research and engineering groups of AECL

  12. Operative arthroscopy.

    Science.gov (United States)

    Guhl, J F

    1979-01-01

    In a period of 20 months, over 200 patients (age ranged from high school students to middle-aged persons) with knee injuries were treated by operative arthroscopy. The majority of the injuries were incurred while the patients had been participating in athletic events, either competitive or recreational. Operative arthroscopy offers the advantage of shortened hospital stay, rapid rehabilitation, lack of disfiguring scar, and reduced costs. Patients are followed yearly after the first postoperative year. Improved long-term results from diagnostic and operative arthroscopy, as compared to conventional surgical procedures, are expected. The proof of those expectations will be determined in the next several years as this group of patients requiring partial meniscectomies or procedures for pathologic and degenerative conditions is reevaluated.

  13. Image Gallery

    Science.gov (United States)

    ... R S T U V W X Y Z Image Gallery Share: The Image Gallery contains high-quality digital photographs available from ... Select a category below to view additional thumbnail images. Images are available for direct download in 2 ...

  14. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This section is concerned with the operation of both the tandem-linac system and the Dynamitron, two accelerators that are used for entirely different research. Developmental activities associated with the tandem and the Dynamitron are also treated here, but developmental activities associated with the superconducting linac are covered separately because this work is a program of technology development in its own right

  15. Operating Systems

    Indian Academy of Sciences (India)

    areas in which this type is useful are multimedia, virtual reality, and advanced scientific projects such as undersea exploration and planetary rovers. Because of the expanded uses for soft real-time functionality, it is finding its way into most current operating systems, including major versions of Unix and Windows NT OS.

  16. Peace Operations

    National Research Council Canada - National Science Library

    Lewis, William

    1995-01-01

    .... Indeed, despite the energetic leadership of Under Secretary-General Kofi R. Annan who directs the Department of Peacekeeping Operations, the organization has increasing difficulty in acquiring properly trained and equipped forces in time to intervene in conflict situations and humanitarian crises.

  17. Operational Circulars

    CERN Multimedia

    2003-01-01

    Operational Circular N° 4 - April 2003 Conditions for use by members of the CERN personnel of vehicles belonging to or rented by CERN - This circular has been drawn up. Operational Circular N° 5 - October 2000 Use of CERN computing facilities - Further details on the personal use of CERN computing facilities Operational Circular N° 5 and its Subsidiary Rules http://cern.ch/ComputingRules defines the rules for the use of CERN computing facilities. One of the basic principles governing such use is that it must come within the professional duties of the user concerned, as defined by the user's divisional hierarchy. However, personal use of the computing facilities is tolerated or allowed provided : a) It is in compliance with Operational Circular N° 5 and not detrimental to official duties, including those of other users; b) the frequency and duration is limited and there is a negligible use of CERN resources; c) it does not constitute a political, commercial and/or profit-making activity; d) it is not...

  18. Operation Context

    DEFF Research Database (Denmark)

    Stüben, Henning; Tietjen, Anne

    2006-01-01

    Abstract: This paper seeks to challenge the notion of context from an operational perspective. Can we grasp the forces that shape the complex conditions for an architectural or urban design within the notion of context? By shifting the gaze towards the agency of architecture, contextual analysis...

  19. Operational indicators

    International Nuclear Information System (INIS)

    2010-01-01

    The chapter presents the operational indicators related to budget, travel costs and tickets, the evolution of the annual program for regulatory inspection, the scientific production, requested patents and the numbers related to the production of the services offered by the Institution

  20. Operator interface programs for KSTAR operation

    International Nuclear Information System (INIS)

    Lee, Sangil; Park, Mikyung; Park, Jinseop; Na, Hoonkyun; Kwon, M.

    2013-01-01

    Beginning the first plasma discharging experiment of KSTAR since 2008, KSTAR performed the third plasma discharging experiment by 2010. During the experiment of three times, KSTAR OPerator Interface (OPI) programs have been developed for KSTAR operation by itself. OPI programs used in KSTAR were implemented by KSTAR widget plug-in Toolkit (KWT). The KWT means the plug-in library implemented by Qt-based user interface development software. The main purpose of developing the KWT library is to implement full automation libraries having interface with the automated EPICS channel access (CA) guaranteeing the flexibility for requirements of operators. In addition, it has advantages in minimizing human code error and maximizing utilization of the limited human resource. According to the increasing of control systems, a number of OPI servers connected to one EPICS gateway server caused the connection problem and increased the amount of the network data packets. To solve these problems, an algorithm of “CachedChannelAccess” for shared memory base was implemented into an inner logic of the KWT library. KSTAR control system monitoring (CSM) program is one of applications developed by using KWT library. The function of CSM program is to notify alarm to operators by checking health status of every server's network health status and resource (cpu, memory, network packets, disk usage rate and system/user defined process) usage state. Another application is a post-shot sequencing program which is activated after every shot is completed. This application is to display major plasma parameters and diagnostic data in chart form, to save this data to database, and to transfer a chart image file to a web server. This paper describes the technical details how to develop OPI applications which have high productivity using Qt on the EPICS-based control system

  1. Operator interface programs for KSTAR operation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sangil, E-mail: leesi@nfri.re.kr; Park, Mikyung, E-mail: mkpark@nfri.re.kr; Park, Jinseop, E-mail: linupark@nfri.re.kr; Na, Hoonkyun, E-mail: hkna@nfri.re.kr; Kwon, M., E-mail: kwonm@nfri.re.kr

    2013-11-15

    Beginning the first plasma discharging experiment of KSTAR since 2008, KSTAR performed the third plasma discharging experiment by 2010. During the experiment of three times, KSTAR OPerator Interface (OPI) programs have been developed for KSTAR operation by itself. OPI programs used in KSTAR were implemented by KSTAR widget plug-in Toolkit (KWT). The KWT means the plug-in library implemented by Qt-based user interface development software. The main purpose of developing the KWT library is to implement full automation libraries having interface with the automated EPICS channel access (CA) guaranteeing the flexibility for requirements of operators. In addition, it has advantages in minimizing human code error and maximizing utilization of the limited human resource. According to the increasing of control systems, a number of OPI servers connected to one EPICS gateway server caused the connection problem and increased the amount of the network data packets. To solve these problems, an algorithm of “CachedChannelAccess” for shared memory base was implemented into an inner logic of the KWT library. KSTAR control system monitoring (CSM) program is one of applications developed by using KWT library. The function of CSM program is to notify alarm to operators by checking health status of every server's network health status and resource (cpu, memory, network packets, disk usage rate and system/user defined process) usage state. Another application is a post-shot sequencing program which is activated after every shot is completed. This application is to display major plasma parameters and diagnostic data in chart form, to save this data to database, and to transfer a chart image file to a web server. This paper describes the technical details how to develop OPI applications which have high productivity using Qt on the EPICS-based control system.

  2. Site operations

    International Nuclear Information System (INIS)

    House, W.B.; Ebenhack, D.G.

    1989-01-01

    This chapter is a discussion of the management and operations practices used at the Barnwell Waste Management Facility in Barnwell, SC. The following topics are discussed: (1) Waste receiving and inspection, including manifest and certificates of compliance, radiological surveys, disposition of nonconforming items, and decontamination and disposition of secondary waste streams; (2) Waste disposal, including Title 10 CFR 61 requirements, disposal area evaluations, shipment offloading, container emplacement, and radiation protection; (3) Trench closure, including trench backfilling, trench capping, and permanent markers; (4) Site maintenance and stabilization, including trench maintenance, surface water management, and site closure activities; (5) Site monitoring programs, including operational monitoring, and environmental monitoring program; (6) Personnel training and qualifications, including basic training program, safety training program, special skills training, and physical qualifications; (7) Records management, including waste records, personnel training records, personnel dosimetry records, site monitoring records, trench qualification and construction records, and site drawings and stabilization records; (8) Site security; (9) Emergency response plans; and (10) Quality assurance

  3. Operators perspective

    International Nuclear Information System (INIS)

    Scragg, D.M.

    1991-01-01

    There are very few Energy from Municipal Waste processing plants in the U.K. Those which were built have usually been financed and operated by Local Authorities and are now in excess of 17 years old. The Environmental Protection Act and constraints on Public Sector spending have brought about fundamental changes in the approach taken to developing new schemes of this kind. The Public Sector and the Private Sector must work together. The investment in Mass Burning Incineration Schemes generating energy is high and the pressures to keep the waste disposal costs as low as possible mean that recovery of the investment needs to be spread over many years. For any Scheme to be successful and financially viable requires a long term commitment on the part of those involved. This paper sets out the key role which the Operating Contractor can play in this situation. (author)

  4. Operating Cigeo

    International Nuclear Information System (INIS)

    Launeau, F.

    2016-01-01

    The CIGEO facility dedicated to the geological disposal of high- and intermediate-level radioactive wastes will be composed of 2 parts: an underground facility at a depth of 500 m to dispose the waste packages in tunnels and a surface facility to take delivery of the wastes and prepare the packages. The underground facility will be built progressively and will cover a surface of 15 km 2 at the end of Cigeo operating-life. A large part of the surface facility (located a few km away from the waste reception place) will be dedicated to the works led deep underground to build the tunnels and will receive drilling cuttings. The article describes also the ramp and carts to lead waste packages underground. Most of the operations will be automated. The definitive closure of the tunnels will be made with swelling clay and concrete plugs. (A.C.)

  5. Imaging arrangement and microscope

    Science.gov (United States)

    Pertsinidis, Alexandros; Chu, Steven

    2015-12-15

    An embodiment of the present invention is an imaging arrangement that includes imaging optics, a fiducial light source, and a control system. In operation, the imaging optics separate light into first and second tight by wavelength and project the first and second light onto first and second areas within first and second detector regions, respectively. The imaging optics separate fiducial light from the fiducial light source into first and second fiducial light and project the first and second fiducial light onto third and fourth areas within the first and second detector regions, respectively. The control system adjusts alignment of the imaging optics so that the first and second fiducial light projected onto the first and second detector regions maintain relatively constant positions within the first and second detector regions, respectively. Another embodiment of the present invention is a microscope that includes the imaging arrangement.

  6. Phase Contrast Imaging

    DEFF Research Database (Denmark)

    1996-01-01

    The invention relates to a method and a system for synthesizing a prescribed intensity pattern based on phase contrast imaging that is not based on the assumption of prior art methods that the pahase shift phi is less than 1 radian. An improved method based on a simple imaging operation...... phasors attain predetermined values for predetermined spatial frequencies, and the phasor value of the specific resolution element of the spatial phase mask corresponds to a distinct intensity level of the image of the resolution element in the intensity pattern, and a spatial phase filter for phase...... shifting of a part of the electromagntic radiation, in combination with an imaging system for generation of the intensity pattern by interference in the image plane of the imaging system between the part of the electromagnetic raidation that has been phase shifted by the phase filter and the remaining part...

  7. Operation Poorman

    International Nuclear Information System (INIS)

    Pruvost, N.; Tsitouras, J.

    1981-01-01

    The objectives of Operation Poorman were to design and build a portable seismic system and to set up and use this system in a cold-weather environment. The equipment design uses current technology to achieve a low-power, lightweight system that is configured into three modules. The system was deployed in Alaska during wintertime, and the results provide a basis for specifying a mission-ready seismic verification system

  8. Methods in quantitative image analysis.

    Science.gov (United States)

    Oberholzer, M; Ostreicher, M; Christen, H; Brühlmann, M

    1996-05-01

    histogram of an existing image (input image) into a new grey value histogram (output image) are most quickly handled by a look-up table (LUT). The histogram of an image can be influenced by gain, offset and gamma of the camera. Gain defines the voltage range, offset defines the reference voltage and gamma the slope of the regression line between the light intensity and the voltage of the camera. A very important descriptor of neighbourhood relations in an image is the co-occurrence matrix. The distance between the pixels (original pixel and its neighbouring pixel) can influence the various parameters calculated from the co-occurrence matrix. The main goals of image enhancement are elimination of surface roughness in an image (smoothing), correction of defects (e.g. noise), extraction of edges, identification of points, strengthening texture elements and improving contrast. In enhancement, two types of operations can be distinguished: pixel-based (point operations) and neighbourhood-based (matrix operations). The most important pixel-based operations are linear stretching of grey values, application of pre-stored LUTs and histogram equalisation. The neighbourhood-based operations work with so-called filters. These are organising elements with an original or initial point in their centre. Filters can be used to accentuate or to suppress specific structures within the image. Filters can work either in the spatial or in the frequency domain. The method used for analysing alterations of grey value intensities in the frequency domain is the Hartley transform. Filter operations in the spatial domain can be based on averaging or ranking the grey values occurring in the organising element. The most important filters, which are usually applied, are the Gaussian filter and the Laplace filter (both averaging filters), and the median filter, the top hat filter and the range operator (all ranking filters). Segmentation of objects is traditionally based on threshold grey values. (AB

  9. Image processing on the image with pixel noise bits removed

    Science.gov (United States)

    Chuang, Keh-Shih; Wu, Christine

    1992-06-01

    Our previous studies used statistical methods to assess the noise level in digital images of various radiological modalities. We separated the pixel data into signal bits and noise bits and demonstrated visually that the removal of the noise bits does not affect the image quality. In this paper we apply image enhancement techniques on noise-bits-removed images and demonstrate that the removal of noise bits has no effect on the image property. The image processing techniques used are gray-level look up table transformation, Sobel edge detector, and 3-D surface display. Preliminary results show no noticeable difference between original image and noise bits removed image using look up table operation and Sobel edge enhancement. There is a slight enhancement of the slicing artifact in the 3-D surface display of the noise bits removed image.

  10. Image digitizer system for bubble chamber laser

    International Nuclear Information System (INIS)

    Haggerty, H.

    1986-01-01

    An IBM PC-based image digitizer system has been assembled to monitor the laser flash used for holography at the 15 foot bubble chamber. The hardware and the operating software are outlined. For an operational test of the system, an array of LEDs was flashed with a 10 microsecond pulse and the image was grabbed by one of the operating programs and processed

  11. Computational acceleration for MR image reconstruction in partially parallel imaging.

    Science.gov (United States)

    Ye, Xiaojing; Chen, Yunmei; Huang, Feng

    2011-05-01

    In this paper, we present a fast numerical algorithm for solving total variation and l(1) (TVL1) based image reconstruction with application in partially parallel magnetic resonance imaging. Our algorithm uses variable splitting method to reduce computational cost. Moreover, the Barzilai-Borwein step size selection method is adopted in our algorithm for much faster convergence. Experimental results on clinical partially parallel imaging data demonstrate that the proposed algorithm requires much fewer iterations and/or less computational cost than recently developed operator splitting and Bregman operator splitting methods, which can deal with a general sensing matrix in reconstruction framework, to get similar or even better quality of reconstructed images.

  12. Image Statistics

    Energy Technology Data Exchange (ETDEWEB)

    Wendelberger, Laura Jean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-08

    In large datasets, it is time consuming or even impossible to pick out interesting images. Our proposed solution is to find statistics to quantify the information in each image and use those to identify and pick out images of interest.

  13. Image Guidance

    Science.gov (United States)

    Guidance that explains the process for getting images approved in One EPA Web microsites and resource directories. includes an appendix that shows examples of what makes some images better than others, how some images convey meaning more than others

  14. Data imaging

    International Nuclear Information System (INIS)

    Pepy, G.

    1999-01-01

    After an introduction about data imaging in general, the principles of imaging data collected via neutron scattering experiments are presented. Some computer programs designed for data imaging purposes are reviewed. (K.A.)

  15. IRIS Mission Operations Director's Colloquium

    Science.gov (United States)

    Carvalho, Robert; Mazmanian, Edward A.

    2014-01-01

    Pursuing the Mysteries of the Sun: The Interface Region Imaging Spectrograph (IRIS) Mission. Flight controllers from the IRIS mission will present their individual experiences on IRIS from development through the first year of flight. This will begin with a discussion of the unique nature of IRISs mission and science, and how it fits into NASA's fleet of solar observatories. Next will be a discussion of the critical roles Ames contributed in the mission including spacecraft and flight software development, ground system development, and training for launch. This will be followed by experiences from launch, early operations, ongoing operations, and unusual operations experiences. The presentation will close with IRIS science imagery and questions.

  16. Medical Imaging Informatics in Nuclear Medicine

    NARCIS (Netherlands)

    van Ooijen, Peter; Glaudemans, Andor W.J.M.; Medema, Jitze; van Zanten, Annie K.; Dierckx, Rudi A.J.O.; Ahaus, C.T.B. (Kees)

    2016-01-01

    Medical imaging informatics is gaining importance in medicine both in clinical practice and in scientific research. Besides radiology, nuclear medicine is also a major stakeholder in medical imaging informatics because of the variety of available imaging modalities and the imaging-oriented operation

  17. Operator errors

    International Nuclear Information System (INIS)

    Knuefer; Lindauer

    1980-01-01

    Besides that at spectacular events a combination of component failure and human error is often found. Especially the Rasmussen-Report and the German Risk Assessment Study show for pressurised water reactors that human error must not be underestimated. Although operator errors as a form of human error can never be eliminated entirely, they can be minimized and their effects kept within acceptable limits if a thorough training of personnel is combined with an adequate design of the plant against accidents. Contrary to the investigation of engineering errors, the investigation of human errors has so far been carried out with relatively small budgets. Intensified investigations in this field appear to be a worthwhile effort. (orig.)

  18. Turbine Imaging Technology Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Moursund, Russell A.; Carlson, Thomas J.

    2004-12-31

    The goal of this project was to identify and evaluate imaging alternatives for observing the behavior of juvenile fish within an operating Kaplan turbine unit with a focus on methods to quantify fish injury mechanisms inside an operating turbine unit. Imaging methods are particularly needed to observe the approach and interaction of fish with turbine structural elements. This evaluation documents both the opportunities and constraints for observing juvenile fish at specific locations during turbine passage. The information may be used to acquire the scientific knowledge to make structural improvements and create opportunities for industry to modify turbines and improve fish passage conditions.

  19. Turbine Imaging Technology Assessment

    International Nuclear Information System (INIS)

    Moursund, Russell A.; Carlson, Thomas J.

    2004-01-01

    The goal of this project was to identify and evaluate imaging alternatives for observing the behavior of juvenile fish within an operating Kaplan turbine unit with a focus on methods to quantify fish injury mechanisms inside an operating turbine unit. Imaging methods are particularly needed to observe the approach and interaction of fish with turbine structural elements. This evaluation documents both the opportunities and constraints for observing juvenile fish at specific locations during turbine passage. The information may be used to acquire the scientific knowledge to make structural improvements and create opportunities for industry to modify turbines and improve fish passage conditions

  20. Pancreatic imaging

    International Nuclear Information System (INIS)

    Potsaid, M.S.

    1978-01-01

    The clinical use of [ 75 Se] selenomethionine for visualising the pancreas is described. The physiological considerations, imaging procedure, image interpretations and reliability are considered. (C.F.)

  1. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Lung Operation After Your Operation Your Discharge and Recovery Complete Video After Your Operation Guidance for after ... Your Lung Operation Read Next Your Discharge and Recovery Back to Top Find A Surgeon Find A ...

  2. Use of a YAP:Ce matrix coupled to a position-sensitive photomultiplier for high resolution positron emission tomography

    International Nuclear Information System (INIS)

    Del Guerra, A.; Zavattini, G.; Notaristefani, F. de; Giganti, M.; Piffanelli, A.; Pani, R.; Turra, A.

    1996-01-01

    A new scintillation detector system has been designed for application in high resolution Positron Emission Tomography (PET). The detector is a bundle of small YAlO 3 :Ce (YAP) crystals closely packed (0.2 x 0.2 x 3.0 cm 3 ), coupled to a position sensitive photomultiplier tube (PSPMT). The preliminary results obtained for spatial resolution, time resolution, energy resolution and efficiency of two such detectors working in coincidence are presented. These are 1.2 mm for the FWHM spatial resolution, 2.0 ns for the FWHM time resolution and 20% for the FWHM energy resolution at 511 keV. The measured efficiency is (44 ± 3)% with a 150 keV threshold and (20 ± 2)% with a 300 keV threshold

  3. Transport Imaging in the One Dimensional Limit

    National Research Council Canada - National Science Library

    Winchell, Stephen D

    2006-01-01

    Transport imaging is a SEM-based technique used to directly image the motion and recombination of charge in luminescent semiconductors, allowing for the extraction of transport parameters critical to device operation...

  4. A frameless stereotaxic operating microscope for neurosurgery

    International Nuclear Information System (INIS)

    Friets, E.M.; Strohbehn, J.W.; Hatch, J.F.; Roberts, D.W.

    1989-01-01

    A new system, which we call the frameless stereotaxic operating microscope, is discussed. Its purpose is to display CT or other image data in the operating microscope in the correct scale, orientation, and position without the use of a stereotaxic frame. A nonimaging ultrasonic rangefinder allows the position of the operating microscope and the position of the patient to be determined. Discrete fiducial points on the patient's external anatomy are located in both image space and operating room space, linking the image data and the operating room. Physician-selected image information, e.g., tumor contours or guidance to predetermined targets, is projected through the optics of the operating microscope using a miniature cathode ray tube and a beam splitter. Projected images superpose the surgical field, reconstructed from image data to match the focal plane of the operating microscope. The algorithms on which the system is based are described, and the sources and effects of errors are discussed. The system's performance is simulated, providing an estimate of accuracy. Two phantoms are used to measure accuracy experimentally. Clinical results and observations are given

  5. A frameless stereotaxic operating microscope for neurosurgery.

    Science.gov (United States)

    Friets, E M; Strohbehn, J W; Hatch, J F; Roberts, D W

    1989-06-01

    A new system, which we call the frameless stereotaxic operating microscope, is discussed. Its purpose is to display CT or other image data in the operating microscope in the correct scale, orientation, and position without the use of a stereotaxic frame. A nonimaging ultrasonic rangefinder allows the position of the operating microscope and the position of the patient to be determined. Discrete fiducial points on the patient's external anatomy are located in both image space and operating room space, linking the image data and the operating room. Physician-selected image information, e.g., tumor contours or guidance to predetermined targets, is projected through the optics of the operating microscope using a miniature cathode ray tube and a beam splitter. Projected images superpose the surgical field, reconstructed from image data to match the focal plane of the operating microscope. The algorithms on which the system is based are described, and the sources and effects of errors are discussed. The system's performance is simulated, providing an estimate of accuracy. Two phantoms are used to measure accuracy experimentally. Clinical results and observations are given.

  6. Digital vascular imaging

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Engels, B.C.H.

    1981-01-01

    Digitalizing videosignals from an image intensifying TV-chain, followed by subtraction, contrast intensifying, and reformation to analogous signal deliver angiography pictures of high quality after intravenous injection of the contrast medium. As the examination is only little invasive it can be carried out on outdoor patients or in the polyclinics. The possibilities of the digital vessel imagination (DVI) are shown at vessel images of different parts of the body; a 36 cm image intensifyer which can be switched to 3 different sorts of operation and has a plumbicon-TV recording tube is used as receiver. (orig.) [de

  7. Operational Law Handbook,2007

    National Research Council Canada - National Science Library

    2007-01-01

    ... & SOFAs, legal assistance, combating terrorism, domestic operations, noncombatant evacuation operations, special operations, civil affairs, air, sea, and space law, detainee operations, reserve...

  8. Understanding and caring for an operating microscope

    Directory of Open Access Journals (Sweden)

    Ismael Cordero

    2014-04-01

    Full Text Available An operating or surgical microscope is an optical instrument that provides the surgeon with a stereoscopic, high quality magnified and illuminated image of the small structures in the surgical area.

  9. Image city

    DEFF Research Database (Denmark)

    2003-01-01

    Image city exhibition explores a condition of mediation, through a focus on image and sound narratives with a point of departure on a number of Asian cities.......Image city exhibition explores a condition of mediation, through a focus on image and sound narratives with a point of departure on a number of Asian cities....

  10. Correlated diffusion imaging

    International Nuclear Information System (INIS)

    Wong, Alexander; Glaister, Jeffrey; Cameron, Andrew; Haider, Masoom

    2013-01-01

    Prostate cancer is one of the leading causes of cancer death in the male population. Fortunately, the prognosis is excellent if detected at an early stage. Hence, the detection and localization of prostate cancer is crucial for diagnosis, as well as treatment via targeted focal therapy. New imaging techniques can potentially be invaluable tools for improving prostate cancer detection and localization. In this study, we introduce a new form of diffusion magnetic resonance imaging called correlated diffusion imaging, where the tissue being imaged is characterized by the joint correlation of diffusion signal attenuation across multiple gradient pulse strengths and timings. By taking into account signal attenuation at different water diffusion motion sensitivities, correlated diffusion imaging can provide improved delineation between cancerous tissue and healthy tissue when compared to existing diffusion imaging modalities. Quantitative evaluation using receiver operating characteristic (ROC) curve analysis, tissue class separability analysis, and visual assessment by an expert radiologist were performed to study correlated diffusion imaging for the task of prostate cancer diagnosis. These results are compared with that obtained using T2-weighted imaging and standard diffusion imaging (via the apparent diffusion coefficient (ADC)). Experimental results suggest that correlated diffusion imaging provide improved delineation between healthy and cancerous tissue and may have potential as a diagnostic tool for cancer detection and localization in the prostate gland. A new form of diffusion magnetic resonance imaging called correlated diffusion imaging (CDI) was developed for the purpose of aiding radiologists in cancer detection and localization in the prostate gland. Preliminary results show CDI shows considerable promise as a diagnostic aid for radiologists in the detection and localization of prostate cancer

  11. Quantum Image Encryption Algorithm Based on Image Correlation Decomposition

    Science.gov (United States)

    Hua, Tianxiang; Chen, Jiamin; Pei, Dongju; Zhang, Wenquan; Zhou, Nanrun

    2015-02-01

    A novel quantum gray-level image encryption and decryption algorithm based on image correlation decomposition is proposed. The correlation among image pixels is established by utilizing the superposition and measurement principle of quantum states. And a whole quantum image is divided into a series of sub-images. These sub-images are stored into a complete binary tree array constructed previously and then randomly performed by one of the operations of quantum random-phase gate, quantum revolving gate and Hadamard transform. The encrypted image can be obtained by superimposing the resulting sub-images with the superposition principle of quantum states. For the encryption algorithm, the keys are the parameters of random phase gate, rotation angle, binary sequence and orthonormal basis states. The security and the computational complexity of the proposed algorithm are analyzed. The proposed encryption algorithm can resist brute force attack due to its very large key space and has lower computational complexity than its classical counterparts.

  12. Retrieval operators of remote sensing applications

    International Nuclear Information System (INIS)

    Ahmad, T.; Shah, A.

    2014-01-01

    A set of operators of remote sensing applications have been proposed to fulfill most of the Functional Requirements (FR). These operators capture the functions of the applications, which can be considered as the services provided by the applications. In general, a good application meets maximum FR from user. In this paper, we have defined a remote sensing application by a set, having all images created at dissimilar time instances, and each image is categorized into set of different layers. (author)

  13. Visual perception and medical imaging

    International Nuclear Information System (INIS)

    Jaffe, C.C.

    1985-01-01

    Medical imaging represents a particularly distinct discipline for image processing since it uniquely depends on the ''expert observer'' and yet models of the human visual system are totally inadequate at the complex level to allow satisfactory prediction of observer response to a given image modification. An illustration of the difficulties in assessing observer performance is shown by a series of optical illustrations which demonstrate that net cognitive behavior is not readily predictable. Although many of these phenomena are often considered as exceptional visual events, the setting of complex images makes it difficult to entirely exclude at least partial operation of these impairments during performance of the diagnostic medical imaging task

  14. Portable Imaging Polarimeter and Imaging Experiments; TOPICAL

    International Nuclear Information System (INIS)

    PHIPPS, GARY S.; KEMME, SHANALYN A.; SWEATT, WILLIAM C.; DESCOUR, M.R.; GARCIA, J.P.; DERENIAK, E.L.

    1999-01-01

    Polarimetry is the method of recording the state of polarization of light. Imaging polarimetry extends this method to recording the spatially resolved state of polarization within a scene. Imaging-polarimetry data have the potential to improve the detection of manmade objects in natural backgrounds. We have constructed a midwave infrared complete imaging polarimeter consisting of a fixed wire-grid polarizer and rotating form-birefringent retarder. The retardance and the orientation angles of the retarder were optimized to minimize the sensitivity of the instrument to noise in the measurements. The optimal retardance was found to be 132(degree) rather than the typical 90(degree). The complete imaging polarimeter utilized a liquid-nitrogen cooled PtSi camera. The fixed wire-grid polarizer was located at the cold stop inside the camera dewar. The complete imaging polarimeter was operated in the 4.42-5(micro)m spectral range. A series of imaging experiments was performed using as targets a surface of water, an automobile, and an aircraft. Further analysis of the polarization measurements revealed that in all three cases the magnitude of circular polarization was comparable to the noise in the calculated Stokes-vector components

  15. Multispectral imaging for medical diagnosis

    Science.gov (United States)

    Anselmo, V. J.

    1977-01-01

    Photography technique determines amount of morbidity present in tissue. Imaging apparatus incorporates numerical filtering. Overall system operates in near-real time. Information gained from this system enables physician to understand extent of injury and leads to accelerated treatment.

  16. An automated image analysis framework for segmentation and division plane detection of single live Staphylococcus aureus cells which can operate at millisecond sampling time scales using bespoke Slimfield microscopy

    Science.gov (United States)

    Wollman, Adam J. M.; Miller, Helen; Foster, Simon; Leake, Mark C.

    2016-10-01

    Staphylococcus aureus is an important pathogen, giving rise to antimicrobial resistance in cell strains such as Methicillin Resistant S. aureus (MRSA). Here we report an image analysis framework for automated detection and image segmentation of cells in S. aureus cell clusters, and explicit identification of their cell division planes. We use a new combination of several existing analytical tools of image analysis to detect cellular and subcellular morphological features relevant to cell division from millisecond time scale sampled images of live pathogens at a detection precision of single molecules. We demonstrate this approach using a fluorescent reporter GFP fused to the protein EzrA that localises to a mid-cell plane during division and is involved in regulation of cell size and division. This image analysis framework presents a valuable platform from which to study candidate new antimicrobials which target the cell division machinery, but may also have more general application in detecting morphologically complex structures of fluorescently labelled proteins present in clusters of other types of cells.

  17. Imaging efficacy of a targeted imaging agent for fluorescence endoscopy

    Science.gov (United States)

    Healey, A. J.; Bendiksen, R.; Attramadal, T.; Bjerke, R.; Waagene, S.; Hvoslef, A. M.; Johannesen, E.

    2008-02-01

    Colorectal cancer is a major cause of cancer death. A significant unmet clinical need exists in the area of screening for earlier and more accurate diagnosis and treatment. We have identified a fluorescence imaging agent targeted to an early stage molecular marker for colorectal cancer. The agent is administered intravenously and imaged in a far red imaging channel as an adjunct to white light endoscopy. There is experimental evidence of preclinical proof of mechanism for the agent. In order to assess potential clinical efficacy, imaging was performed with a prototype fluorescence endoscope system designed to produce clinically relevant images. A clinical laparoscope system was modified for fluorescence imaging. The system was optimised for sensitivity. Images were recorded at settings matching those expected with a clinical endoscope implementation (at video frame rate operation). The animal model was comprised of a HCT-15 xenograft tumour expressing the target at concentration levels expected in early stage colorectal cancer. Tumours were grown subcutaneously. The imaging agent was administered intravenously at a dose of 50nmol/kg body weight. The animals were killed 2 hours post administration and prepared for imaging. A 3-4mm diameter, 1.6mm thick slice of viable tumour was placed over the opened colon and imaged with the laparoscope system. A receiver operator characteristic analysis was applied to imaging results. An area under the curve of 0.98 and a sensitivity of 87% [73, 96] and specificity of 100% [93, 100] were obtained.

  18. Hybrid Imaging: A New Frontier in Medical Imaging

    OpenAIRE

    Bijan Bijan

    2010-01-01

    Introduction of hybrid imaging in the arena of medical imaging calls for re-strategizing in current practice. Operating PET-CT and upcoming PET-MRI is a turf battle between Radiologists, Nuclear Medicine Physicians, Oncologists, Cardiologists and other related fields.

  19. Diagnostic imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Gradzki, J.; Nowak, S.; Paprzycki, W.

    1993-01-01

    40 patients have been examined with operational and histological confirmation of craniopharyngioma. CT image and X-ray plane of skull were performed in case all of these patients. TMR was conformed to examine 4 patients. X-ray planes was compared to CT. CT permits tumor cyst detection. The efficacy of mentioned above diagnostic techniques was compared with surgical findings. (author)

  20. Medical imaging systems

    Science.gov (United States)

    Frangioni, John V [Wayland, MA

    2012-07-24

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remains in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may also employ dyes or other fluorescent substances associated with antibodies, antibody fragments, or ligands that accumulate within a region of diagnostic significance. In one embodiment, the system provides an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide that is used to capture images. In another embodiment, the system is configured for use in open surgical procedures by providing an operating area that is closed to ambient light. More broadly, the systems described herein may be used in imaging applications where a visible light image may be usefully supplemented by an image formed from fluorescent emissions from a fluorescent substance that marks areas of functional interest.

  1. Advanced millimeter wave imaging systems

    Science.gov (United States)

    Schuchardt, J. M.; Gagliano, J. A.; Stratigos, J. A.; Webb, L. L.; Newton, J. M.

    1980-01-01

    Unique techniques are being utilized to develop self-contained imaging radiometers operating at single and multiple frequencies near 35, 95 and 183 GHz. These techniques include medium to large antennas for high spatial resolution, lowloss open structures for RF confinemnt and calibration, wide bandwidths for good sensitivity plus total automation of the unit operation and data collection. Applications include: detection of severe storms, imaging of motor vehicles, and the remote sensing of changes in material properties.

  2. Maxillofacial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Larheim, T.A. [Oslo Univ. (Norway). Dept. of Maxillofacial Radiology; Westesson, P.L. [Univ. of Rochester School of Medicine and Dentistry, NY (United States). Div. of Diagnostic and Interventional Radiology

    2006-07-01

    Maxillofacial imaging has evolved dramatically over the past two decades with development of new cross-sectional imaging techniques. Traditional maxillofacial imaging was based on plain films and dental imaging. However, today's advanced imaging techniques with CT and MRI have only been partially implemented for maxillofacial questions. This book bridges the gap between traditional maxillofacial imaging and advanced medical imaging. We have applied CT and MRI to a variety of maxillofacial cases and these are illustrated with high-quality images and multiple planes. A comprehensive chapter on imaging anatomy is also included. This book is useful for oral and maxillofacial radiologists, oral and maxillofacial surgeons, dentists, radiologists, plastic surgeons, head and neck surgeons, and others that work with severe maxillofacial disorders. (orig.)

  3. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Beer, A.; Bielke, G.; Bockenheimer, S.; Brenner, G.; Dieringer, H.; Esswein, H.; Hopf, H.; Koch, H.; Meves, M.; Nagel, F.; Oberstein, A.; Ostheimer, E.; Pfaff, M.; Schlaps, D.; Schopka, H.J.; Seiderer, M.

    1990-01-01

    The study investigates three points of main interest: (1) The clinical efficacy of MR imaging as a routine method, if possible to be assessed in comparison to comparable imaging methods, and referring to a broad spectrum of available types of equipment and modes of operation, to be expressed in terms of diagnostic value and indication of therapy. (2) Specific economic aspects, considering different sites of operation and application conditions. (3) Results of clinical application with regard to individual cases (patient careers), in order to establish a nationwide basis for economic cost-benefit assessment of this diagnostic tool. Another aspect taken into account whenever available data allow so, is substitutional or additional application of MR imaging. The survey is performed on the basis of data accumulated by more than 21.000 MR examinations, and of data describing the application environment, furnished by 25 users from university hospitals, general hospitals, or private practice. (orig./HP) [de

  4. Multipurpose Hyperspectral Imaging System

    Science.gov (United States)

    Mao, Chengye; Smith, David; Lanoue, Mark A.; Poole, Gavin H.; Heitschmidt, Jerry; Martinez, Luis; Windham, William A.; Lawrence, Kurt C.; Park, Bosoon

    2005-01-01

    A hyperspectral imaging system of high spectral and spatial resolution that incorporates several innovative features has been developed to incorporate a focal plane scanner (U.S. Patent 6,166,373). This feature enables the system to be used for both airborne/spaceborne and laboratory hyperspectral imaging with or without relative movement of the imaging system, and it can be used to scan a target of any size as long as the target can be imaged at the focal plane; for example, automated inspection of food items and identification of single-celled organisms. The spectral resolution of this system is greater than that of prior terrestrial multispectral imaging systems. Moreover, unlike prior high-spectral resolution airborne and spaceborne hyperspectral imaging systems, this system does not rely on relative movement of the target and the imaging system to sweep an imaging line across a scene. This compact system (see figure) consists of a front objective mounted at a translation stage with a motorized actuator, and a line-slit imaging spectrograph mounted within a rotary assembly with a rear adaptor to a charged-coupled-device (CCD) camera. Push-broom scanning is carried out by the motorized actuator which can be controlled either manually by an operator or automatically by a computer to drive the line-slit across an image at a focal plane of the front objective. To reduce the cost, the system has been designed to integrate as many as possible off-the-shelf components including the CCD camera and spectrograph. The system has achieved high spectral and spatial resolutions by using a high-quality CCD camera, spectrograph, and front objective lens. Fixtures for attachment of the system to a microscope (U.S. Patent 6,495,818 B1) make it possible to acquire multispectral images of single cells and other microscopic objects.

  5. Turbine imaging technology assessment

    Energy Technology Data Exchange (ETDEWEB)

    Moursund, R. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Carlson, T. J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2004-12-01

    The goal of this project was to identify and evaluate imaging technologies for observing juvenile fish within a Kaplan turbine, and specifically that would enable scientists to determine mechanisms of fish injury within an operating turbine unit. This report documents the opportunities and constraints for observing juvenile fish at specific locations during turbine passage. These observations were used to make modifications to dam structures and operations to improve conditions for fish passage while maintaining or improving hydropower production. The physical and hydraulic environment that fish experience as they pass through the hydroelectric plants were studied and the regions with the greatest potential for injury were defined. Biological response data were also studied to determine the probable types of injuries sustained in the turbine intake and what types of injuries are detectable with imaging technologies. The study grouped injury-causing mechanisms into two categories: fluid (pressure/cavitation, shear, turbulence) and mechanical (strike/collision, grinding/pinching, scraping). The physical constraints of the environment, together with the likely types of injuries to fish, provided the parameters needed for a rigorous imaging technology evaluation. Types of technology evaluated included both tracking and imaging systems using acoustic technologies (such as sonar and acoustic tags) and optic technologies (such as pulsed-laser videography, which is high-speed videography using a laser as the flash). Criteria for determining image data quality such as frame rate, target detectability, and resolution were used to quantify the minimum requirements of an imaging sensor.

  6. Current concepts in maxillofacial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Boeddinghaus, Rudolf [Perth Radiological Clinic, 127 Hamersley Road, Subiaco, Western Australia 6008 (Australia)], E-mail: rboeddinghaus@perthradclinic.com.au; Whyte, Andy [Perth Radiological Clinic, 127 Hamersley Road, Subiaco, Western Australia 6008 (Australia)], E-mail: awhyte@perthradclinic.com.au

    2008-06-15

    A review of state-of-the-art maxillofacial imaging is presented. Current imaging techniques include intra-oral radiographs, dental panoramic tomography, multidetector helical computed tomography, cone-beam computed tomography (CBCT) and magnetic resonance imaging (MRI). The commonest conditions encountered in clinical radiological practice are reviewed, including maxillofacial deformities, complicated dental impactions, maxillofacial trauma, jaw lesions (cysts, neoplasms, fibro-osseous lesions (FOLs) and infections), and temporomandibular joint pathology. Pre-operative assessment for dental implant placement is also briefly reviewed.

  7. Imaging angiogenesis.

    Science.gov (United States)

    Charnley, Natalie; Donaldson, Stephanie; Price, Pat

    2009-01-01

    There is a need for direct imaging of effects on tumor vasculature in assessment of response to antiangiogenic drugs and vascular disrupting agents. Imaging tumor vasculature depends on differences in permeability of vasculature of tumor and normal tissue, which cause changes in penetration of contrast agents. Angiogenesis imaging may be defined in terms of measurement of tumor perfusion and direct imaging of the molecules involved in angiogenesis. In addition, assessment of tumor hypoxia will give an indication of tumor vasculature. The range of imaging techniques available for these processes includes positron emission tomography (PET), dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), perfusion computed tomography (CT), and ultrasound (US).

  8. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... You Want to Be a Surgeon Resident Resources Teaching Resources Online Guide to Choosing a Surgical Residency ... After Your Operation Your Discharge and Recovery Complete Video After Your Operation Guidance for after the operation ...

  9. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Medical Student Core Curriculum ACS/ASE Medical Student Simulation-Based Surgical Skills Curriculum Cancer Education Cancer Education ... Surgeons Education Patients and Family Skills Programs Your Lung Operation Your Lung Operation DVD After Your Operation ...

  10. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Overview ACS-AEI Consortium Quarterly ACS Chapter News Cancer ... American College of Surgeons Education Patients and Family Skills Programs Your Lung Operation Your Lung Operation DVD After Your Operation ...

  11. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Liability Surgeons as Advocates Surgeons and Bundled Payment Models Surgeons as Institutional Employees Our Changing Health Care ... Lung Operation After Your Operation Your Discharge and Recovery Complete Video After Your Operation Guidance for after ...

  12. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Safety Resources About the Patient Education Program The Recovery Room Choosing Wisely Educational Programs Educational Programs Educational ... Lung Operation After Your Operation Your Discharge and Recovery Complete Video After Your Operation Guidance for after ...

  13. Operator theory, operator algebras and applications

    CERN Document Server

    Lebre, Amarino; Samko, Stefan; Spitkovsky, Ilya

    2014-01-01

    This book consists of research papers that cover the scientific areas of the International Workshop on Operator Theory, Operator Algebras and Applications, held in Lisbon in September 2012. The volume particularly focuses on (i) operator theory and harmonic analysis (singular integral operators with shifts; pseudodifferential operators, factorization of almost periodic matrix functions; inequalities; Cauchy type integrals; maximal and singular operators on generalized Orlicz-Morrey spaces; the Riesz potential operator; modification of Hadamard fractional integro-differentiation), (ii) operator algebras (invertibility in groupoid C*-algebras; inner endomorphisms of some semi group, crossed products; C*-algebras generated by mappings which have finite orbits; Folner sequences in operator algebras; arithmetic aspect of C*_r SL(2); C*-algebras of singular integral operators; algebras of operator sequences) and (iii) mathematical physics (operator approach to diffraction from polygonal-conical screens; Poisson geo...

  14. KEPLER SCIENCE OPERATIONS

    International Nuclear Information System (INIS)

    Haas, Michael R.; Bryson, Steve T.; Dotson, Jessie L.; Koch, David G.; Smith, Marcie; Sobeck, Charles K.; Batalha, Natalie M.; Caldwell, Douglas A.; Jenkins, Jon M.; Van Cleve, Jeffrey E.; Hall, Jennifer; Klaus, Todd C.; Middour, Chris; Thompson, Richard S.; Kolodziejczak, Jeffrey; Stober, Jeremy

    2010-01-01

    Kepler's mission design includes a comprehensive plan for commissioning and science operations. The commissioning phase completed all critical tasks and accomplished all mission objectives within a week of the pre-launch plan. Since the start of science data collection, the nominal timeline has been interrupted by two safe-mode events, several losses of fine point, and some small pointing adjustments. The most important anomalies are understood and mitigated, so Kepler's technical performance has improved significantly over this period, and the prognosis for mission success is excellent. The Kepler data archive is established and hosting data for the science team, guest observers, and the public. The first data to become publicly available include the monthly full-frame images and the light curves for targets that are dropped from the exoplanet program or released after publication. Data are placed in the archive on a quarterly basis; the Kepler Results Catalog will be released annually starting in 2011.

  15. Medical image registration for analysis

    International Nuclear Information System (INIS)

    Petrovic, V.

    2006-01-01

    Full text: Image registration techniques represent a rich family of image processing and analysis tools that aim to provide spatial correspondences across sets of medical images of similar and disparate anatomies and modalities. Image registration is a fundamental and usually the first step in medical image analysis and this paper presents a number of advanced techniques as well as demonstrates some of the advanced medical image analysis techniques they make possible. A number of both rigid and non-rigid medical image alignment algorithms of equivalent and merely consistent anatomical structures respectively are presented. The algorithms are compared in terms of their practical aims, inputs, computational complexity and level of operator (e.g. diagnostician) interaction. In particular, the focus of the methods discussion is placed on the applications and practical benefits of medical image registration. Results of medical image registration on a number of different imaging modalities and anatomies are presented demonstrating the accuracy and robustness of their application. Medical image registration is quickly becoming ubiquitous in medical imaging departments with the results of such algorithms increasingly used in complex medical image analysis and diagnostics. This paper aims to demonstrate at least part of the reason why

  16. Intra-operative application of optical coherence tomography with an operating microscope.

    Science.gov (United States)

    Just, T; Lankenau, E; Hüttmann, G; Pau, H W

    2009-09-01

    To introduce the use of optical coherence tomography with an operating microscope for intra-operative evaluation of the human larynx. A specially equipped operating microscope with integrated spectral domain optical coherence tomography apparatus was used during microlaryngoscopy. Technical improvements in optical coherence tomography equipment (e.g. pilot beam, variable focal distance, improved image quality and integration into an operating microscope) have enabled greater sensitivity and imaging speed and a non-contact approach. Spectral domain optical coherence tomography now enables a better correlation between optical coherence tomography images and histological findings. With this new technology, the precision of biopsy can be improved during microlaryngoscopy. Use of this new optical coherence tomography technology, integrated into an operating microscope, enables the surgeon to define the biopsy site location and resection plane precisely, while the optical zoom of the operating microscope can be used over the complete range.

  17. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    Science.gov (United States)

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  18. Spinal imaging and image analysis

    CERN Document Server

    Yao, Jianhua

    2015-01-01

    This book is instrumental to building a bridge between scientists and clinicians in the field of spine imaging by introducing state-of-the-art computational methods in the context of clinical applications.  Spine imaging via computed tomography, magnetic resonance imaging, and other radiologic imaging modalities, is essential for noninvasively visualizing and assessing spinal pathology. Computational methods support and enhance the physician’s ability to utilize these imaging techniques for diagnosis, non-invasive treatment, and intervention in clinical practice. Chapters cover a broad range of topics encompassing radiological imaging modalities, clinical imaging applications for common spine diseases, image processing, computer-aided diagnosis, quantitative analysis, data reconstruction and visualization, statistical modeling, image-guided spine intervention, and robotic surgery. This volume serves a broad audience as  contributions were written by both clinicians and researchers, which reflects the inte...

  19. Urogenital imaging

    International Nuclear Information System (INIS)

    Hamm, B.; Charite - Universitaetsmedizin Berlin; Asbach, P.; Beyersdorff, D.; Hein, P.; Lemke, U.

    2008-01-01

    The book in direct diagnosis in radiology, urogenital imaging, includes information concerning definition, imaging signs and clinical aspects on the following topics: kidneys and adrenals, the urinary tract, the male genitals and the female genitals

  20. Medical Imaging.

    Science.gov (United States)

    Barker, M. C. J.

    1996-01-01

    Discusses four main types of medical imaging (x-ray, radionuclide, ultrasound, and magnetic resonance) and considers their relative merits. Describes important recent and possible future developments in image processing. (Author/MKR)

  1. Microwave imaging

    CERN Document Server

    Pastorino, Matteo

    2010-01-01

    An introduction to the most relevant theoretical and algorithmic aspects of modern microwave imaging approaches Microwave imaging-a technique used in sensing a given scene by means of interrogating microwaves-has recently proven its usefulness in providing excellent diagnostic capabilities in several areas, including civil and industrial engineering, nondestructive testing and evaluation, geophysical prospecting, and biomedical engineering. Microwave Imaging offers comprehensive descriptions of the most important techniques so far proposed for short-range microwave imaging-in

  2. Acoustical holographic Siamese image technique for imaging radial cracks in reactor piping

    International Nuclear Information System (INIS)

    Collins, H.D.; Gribble, R.P.

    1985-04-01

    This paper describes a unique technique (i.e., ''Siamese imaging'') for imaging quasi-vertical defects in reactor pipe weldments. The Siamese image is a bi-symmetrical view of the inner surface defect. Image construction geometry consists of two probes (i.e., source/receiver) operating either from opposite sides or the same side of the defect to be imaged. As the probes are scanned across a lower surface connected defect, they encounter two images - first the normal upright image and then the inverted image. The final integrated image consists of two images connected along their baselines, thus we call it a ''Siamese image.'' The experimental imaging results on simulated and natural cracks in reactor piping weldments graphically illustrate this unique technique. Excellent images of mechanical fatique and thermal cracks were obtained on ferritic and austenitic piping

  3. Nuclear medicine imaging and data processing

    International Nuclear Information System (INIS)

    Bell, P.R.; Dillon, R.S.

    1978-01-01

    The Oak Ridge Imaging System (ORIS) is a software operating system structure around the Digital Equipment Corporation's PDP-8 minicomputer which provides a complete range of image manipulation procedures. Through its modular design it remains open-ended for easy expansion to meet future needs. Already included in the system are image access routines for use with the rectilinear scanner or gamma camera (both static and flow studies); display hardware design and corresponding software; archival storage provisions; and, most important, many image processing techniques. The image processing capabilities include image defect removal, smoothing, nonlinear bounding, preparation of functional images, and transaxial emission tomography reconstruction from a limited number of views

  4. A Survey on Operator Monotonicity, Operator Convexity, and Operator Means

    Directory of Open Access Journals (Sweden)

    Pattrawut Chansangiam

    2015-01-01

    Full Text Available This paper is an expository devoted to an important class of real-valued functions introduced by Löwner, namely, operator monotone functions. This concept is closely related to operator convex/concave functions. Various characterizations for such functions are given from the viewpoint of differential analysis in terms of matrix of divided differences. From the viewpoint of operator inequalities, various characterizations and the relationship between operator monotonicity and operator convexity are given by Hansen and Pedersen. In the viewpoint of measure theory, operator monotone functions on the nonnegative reals admit meaningful integral representations with respect to Borel measures on the unit interval. Furthermore, Kubo-Ando theory asserts the correspondence between operator monotone functions and operator means.

  5. CT images of gossypiboma

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee

    1994-01-01

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment

  6. CT images of gossypiboma

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee [College of Medicine, Kon-Kuk University, Seoul (Korea, Republic of)

    1994-04-15

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment.

  7. Tomographic imaging

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    Tomography is used to image anatomy of organs as in the case of CT and MRI or image body functions as in the case of SPECT and PET. The theory of reconstruction applies equally well to CT, SPECT and PET with a minor differences. The main difference between SPECT and PET is that SPECT images single photon emitters (radionuclides) which emit normal gamma rays (like Tc-99m), whereas PET images positron emitting radionuclides such as O 15 or F 18 . The word tomography means drawing of the body. Every tomography results in an image of the inside of the body and is represented as a slice. (author)

  8. Digital processing of radiographic images

    Science.gov (United States)

    Bond, A. D.; Ramapriyan, H. K.

    1973-01-01

    Some techniques are presented and the software documentation for the digital enhancement of radiographs. Both image handling and image processing operations are considered. The image handling operations dealt with are: (1) conversion of format of data from packed to unpacked and vice versa; (2) automatic extraction of image data arrays; (3) transposition and 90 deg rotations of large data arrays; (4) translation of data arrays for registration; and (5) reduction of the dimensions of data arrays by integral factors. Both the frequency and the spatial domain approaches are presented for the design and implementation of the image processing operation. It is shown that spatial domain recursive implementation of filters is much faster than nonrecursive implementations using fast fourier transforms (FFT) for the cases of interest in this work. The recursive implementation of a class of matched filters for enhancing image signal to noise ratio is described. Test patterns are used to illustrate the filtering operations. The application of the techniques to radiographic images of metallic structures is demonstrated through several examples.

  9. Gamma-ray Imaging Methods

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, K; Mihailescu, L; Nelson, K; Valentine, J; Wright, D

    2006-10-05

    In this document we discuss specific implementations for gamma-ray imaging instruments including the principle of operation and describe systems which have been built and demonstrated as well as systems currently under development. There are several fundamentally different technologies each with specific operational requirements and performance trade offs. We provide an overview of the different gamma-ray imaging techniques and briefly discuss challenges and limitations associated with each modality (in the appendix we give detailed descriptions of specific implementations for many of these technologies). In Section 3 we summarize the performance and operational aspects in tabular form as an aid for comparing technologies and mapping technologies to potential applications.

  10. Stereoscopic medical imaging collaboration system

    Science.gov (United States)

    Okuyama, Fumio; Hirano, Takenori; Nakabayasi, Yuusuke; Minoura, Hirohito; Tsuruoka, Shinji

    2007-02-01

    The computerization of the clinical record and the realization of the multimedia have brought improvement of the medical service in medical facilities. It is very important for the patients to obtain comprehensible informed consent. Therefore, the doctor should plainly explain the purpose and the content of the diagnoses and treatments for the patient. We propose and design a Telemedicine Imaging Collaboration System which presents a three dimensional medical image as X-ray CT, MRI with stereoscopic image by using virtual common information space and operating the image from a remote location. This system is composed of two personal computers, two 15 inches stereoscopic parallax barrier type LCD display (LL-151D, Sharp), one 1Gbps router and 1000base LAN cables. The software is composed of a DICOM format data transfer program, an operation program of the images, the communication program between two personal computers and a real time rendering program. Two identical images of 512×768 pixcels are displayed on two stereoscopic LCD display, and both images show an expansion, reduction by mouse operation. This system can offer a comprehensible three-dimensional image of the diseased part. Therefore, the doctor and the patient can easily understand it, depending on their needs.

  11. Building country image process

    Directory of Open Access Journals (Sweden)

    Zubović Jovan

    2005-01-01

    Full Text Available The same branding principles are used for countries as they are used for the products, only the methods are different. Countries are competing among themselves in tourism, foreign investments and exports. Country turnover is at the level that the country's reputation is. The countries that begin as unknown or with a bad image will have limits in operations or they will be marginalized. As a result they will be at the bottom of the international influence scale. On the other hand, countries with a good image, like Germany (despite two world wars will have their products covered with a special "aura".

  12. Thermal Infrared Imaging of Exoplanets

    International Nuclear Information System (INIS)

    Apai, Daniel

    2009-01-01

    High-contrast imaging remains the only way to search for and study weakly-irradiated giant exoplanets. We review here in brief a new high-contrast imaging technique that operates in the 3-5 μm window and show the exquisite sensitivity that can be reached using this technique. The two key advantages of the L-band high-contrast imaging are the superior image quality and the 2-to 4-magnitude gain in sensitivity provided by the red color of giant planets. Most excitingly, this method can be applied to constrain the yet-unexplored giant planet population at radii between 3 and 30 AU.

  13. Operational radiation protection in the PET/MRI Installation of Research Laboratory of Human Cardiovascular imaging of the CNIC; Proteccion radiologica operacional en la instalacion PET/RM del laboratorio de investigacion de imagen cardiovascular humana del CNIC

    Energy Technology Data Exchange (ETDEWEB)

    Escudero Toro, R.; Delgado Alberquilla, R.; Moreno Lopez, J.; Lopez, G.

    2013-07-01

    The objective of this study is to describe the implications in the design of facilities, shielding calculation and design of radioactive sources of calibration encapsulated compatible with RM and, on the other hand, specify, after the start-up of the laboratory, the operational monitoring of the installation, the use of monitors pollution and radiation within the room and its compatibility with the RM, dosimetry control area and exposed personnel and occupational radiation protection and the patient. (Author)

  14. Acoustical Imaging

    CERN Document Server

    Litniewski, Jerzy; Kujawska, Tamara; 31st International Symposium on Acoustical Imaging

    2012-01-01

    The International Symposium on Acoustical Imaging is a unique forum for advanced research, covering new technologies, developments, methods and theories in all areas of acoustics. This interdisciplinary Symposium has been taking place continuously since 1968. In the course of the years the proceedings volumes in the Acoustical Imaging Series have become a reference for cutting-edge research in the field. In 2011 the 31st International Symposium on Acoustical Imaging was held in Warsaw, Poland, April 10-13. Offering both a broad perspective on the state-of-the-art as well as  in-depth research contributions by the specialists in the field, this Volume 31 in the Series contains an excellent collection of papers in six major categories: Biological and Medical Imaging Physics and Mathematics of Acoustical Imaging Acoustic Microscopy Transducers and Arrays Nondestructive Evaluation and Industrial Applications Underwater Imaging

  15. Cerenkov Imaging

    OpenAIRE

    Das, Sudeep; Thorek, Daniel L.J.; Grimm, Jan

    2014-01-01

    Cerenkov luminescence (CL) has been used recently in a plethora of medical applications like imaging and therapy with clinically relevant medical isotopes. The range of medical isotopes used is fairly large and expanding. The generation of in vivo light is useful since it circumvents depth limitations for excitation light. Cerenkov luminescence imaging (CLI) is much cheaper in terms of infrastructure than positron emission tomography (PET) and is particularly useful for imaging of superficial...

  16. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... to Participate Resources Webinars for Young Surgeons YFA E-News YFA Advocacy Essay Contest Resident and Associate ... ACS Leader International Exchange Scholar Program Resources RAS E-News Medical Students Operation Giving Back Operation Giving ...

  17. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Careers at ACS Careers at ACS About ACS Career Types Working at ACS ... ( 0 ) Cart Donate American College of Surgeons Education Patients and Family Skills Programs Your Lung Operation Your Lung Operation DVD ...

  18. Advanced 3-D Ultrasound Imaging

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer

    The main purpose of the PhD project was to develop methods that increase the 3-D ultrasound imaging quality available for the medical personnel in the clinic. Acquiring a 3-D volume gives the medical doctor the freedom to investigate the measured anatomy in any slice desirable after the scan has...... been completed. This allows for precise measurements of organs dimensions and makes the scan more operator independent. Real-time 3-D ultrasound imaging is still not as widespread in use in the clinics as 2-D imaging. A limiting factor has traditionally been the low image quality achievable using...... a channel limited 2-D transducer array and the conventional 3-D beamforming technique, Parallel Beamforming. The first part of the scientific contributions demonstrate that 3-D synthetic aperture imaging achieves a better image quality than the Parallel Beamforming technique. Data were obtained using both...

  19. Multimodality image analysis work station

    International Nuclear Information System (INIS)

    Ratib, O.; Huang, H.K.

    1989-01-01

    The goal of this project is to design and implement a PACS (picture archiving and communication system) workstation for quantitative analysis of multimodality images. The Macintosh II personal computer was selected for its friendly user interface, its popularity among the academic and medical community, and its low cost. The Macintosh operates as a stand alone workstation where images are imported from a central PACS server through a standard Ethernet network and saved on a local magnetic or optical disk. A video digitizer board allows for direct acquisition of images from sonograms or from digitized cine angiograms. The authors have focused their project on the exploration of new means of communicating quantitative data and information through the use of an interactive and symbolic user interface. The software developed includes a variety of image analysis, algorithms for digitized angiograms, sonograms, scintigraphic images, MR images, and CT scans

  20. Tomographic imaging system

    International Nuclear Information System (INIS)

    Hayakawa, T.; Horiba, I.; Kohno, H.; Nakaya, C.; Sekihara, K.; Shiono, H.; Tomura, T.; Yamamoto, S.; Yanaka, S.

    1980-01-01

    A tomographic imaging system comprising: irradiating means for irradating a cross-section of an object under consideration with radiation rays from plural directions; detector means for detecting the radiation rays transmitted through the cross-section of said object to produce an output signal; first memory means for storing the output signal of said detector means; and an image jreconstructing section for performing a convolution integral operation on the contents of said first memory means by means of a first weighting function to reconstruct a three-dimensional image of the cross-section of said object, said image reconstructing section including (I) second memory means for storing a second weighting function, said second weighting function being provided with a predetermined positive and negative (N-1)th order when the output signal of said detector means produced by the irradiation of the cross-section of said object from one of said plural directions is sampled by N points, the value of the (N-1)th order of said second weighting function being an integration of said first weighting function from the (N-1)th order to positive infinity and the value of -(N-1)th order of said second weighting function being an integration of said first weighting function from the -(N-1)th order to negative infinity, (II) control means for successively reading out the contents of said first and second memory means, and (III) operational means for performing multiplying and summing operations on the read-out contents of said first and second memory means, said operational means producing the product of the values fo the (N-1)th and -(N-1)th orders of said second weighting function and a component of the output signal of said detector means relating to the radiation rays free from the absorption thereof by said object

  1. Planetary Hyperspectral Imager (PHI)

    Science.gov (United States)

    Silvergate, Peter

    1996-01-01

    A hyperspectral imaging spectrometer was breadboarded. Key innovations were use of a sapphire prism and single InSb focal plane to cover the entire spectral range, and a novel slit optic and relay optics to reduce thermal background. Operation over a spectral range of 450 - 4950 nm (approximately 3.5 spectral octaves) was demonstrated. Thermal background reduction by a factor of 8 - 10 was also demonstrated.

  2. Dual source CT imaging

    International Nuclear Information System (INIS)

    Seidensticker, Peter R.; Hofmann, Lars K.

    2008-01-01

    The introduction of Dual Source Computed Tomography (DSCT) in 2005 was an evolutionary leap in the field of CT imaging. Two x-ray sources operated simultaneously enable heart-rate independent temporal resolution and routine spiral dual energy imaging. The precise delivery of contrast media is a critical part of the contrast-enhanced CT procedure. This book provides an introduction to DSCT technology and to the basics of contrast media administration followed by 25 in-depth clinical scan and contrast media injection protocols. All were developed in consensus by selected physicians on the Dual Source CT Expert Panel. Each protocol is complemented by individual considerations, tricks and pitfalls, and by clinical examples from several of the world's best radiologists and cardiologists. This extensive CME-accredited manual is intended to help readers to achieve consistently high image quality, optimal patient care, and a solid starting point for the development of their own unique protocols. (orig.)

  3. ImageX: new and improved image explorer for astronomical images and beyond

    Science.gov (United States)

    Hayashi, Soichi; Gopu, Arvind; Kotulla, Ralf; Young, Michael D.

    2016-08-01

    The One Degree Imager - Portal, Pipeline, and Archive (ODI-PPA) has included the Image Explorer interactive image visualization tool since it went operational. Portal users were able to quickly open up several ODI images within any HTML5 capable web browser, adjust the scaling, apply color maps, and perform other basic image visualization steps typically done on a desktop client like DS9. However, the original design of the Image Explorer required lossless PNG tiles to be generated and stored for all raw and reduced ODI images thereby taking up tens of TB of spinning disk space even though a small fraction of those images were being accessed by portal users at any given time. It also caused significant overhead on the portal web application and the Apache webserver used by ODI-PPA. We found it hard to merge in improvements made to a similar deployment in another project's portal. To address these concerns, we re-architected Image Explorer from scratch and came up with ImageX, a set of microservices that are part of the IU Trident project software suite, with rapid interactive visualization capabilities useful for ODI data and beyond. We generate a full resolution JPEG image for each raw and reduced ODI FITS image before producing a JPG tileset, one that can be rendered using the ImageX frontend code at various locations as appropriate within a web portal (for example: on tabular image listings, views allowing quick perusal of a set of thumbnails or other image sifting activities). The new design has decreased spinning disk requirements, uses AngularJS for the client side Model/View code (instead of depending on backend PHP Model/View/Controller code previously used), OpenSeaDragon to render the tile images, and uses nginx and a lightweight NodeJS application to serve tile images thereby significantly decreasing the Time To First Byte latency by a few orders of magnitude. We plan to extend ImageX for non-FITS images including electron microscopy and radiology scan

  4. NMR imaging

    International Nuclear Information System (INIS)

    Andrew, E.R.

    1983-01-01

    Since hydrogen is the most abundant element in all living organisms, proton NMR lends itself well as a method of investigation in biology and medicine. NMR imaging has some special advantages as a diagnostic tool: no ionizing radiation is used, it is noninvasive; it provides a safer means of imaging than the use of x-rays, gamma rays, positrons, or heavy ions. In contrast with ultrasound, the radiation penetrates the bony structures without attenuation. In additional to morphological information, NMR imaging provides additional diagnostic insights through relaxation parameters, which are not available from other imaging methods. In the decade since the first primitive NMR images were obtained, the quality of images now obtained approaches those from CT x-ray scanners. Prototype instruments are being constructed for clinical evaluation and the first whole-body scanners are beginning to appear on the market at costs comparable to CT scanners. Primary differences in equipment for conventional NMR and NMR imaging are the much larger aperture magnets that are required for the examination of human subjects and the addition of coils to generate field gradients and facilities for manipulating the gradients. Early results from clinical trials in many parts of the world are encouraging, and in a few years, the usefuleness of this modality of medical imaging to the medical profession in diagnosis and treatment of disease will be defined. 10 figures

  5. Nuclear imaging

    International Nuclear Information System (INIS)

    Miller, J.H.; Reid, B.S.

    1985-01-01

    Nuclear imaging, utilizing relatively low photon energy emitting isotopes, allows an assessment of anatomic configuration and organ function. This method of imaging is predicted on the utilization of physiologically active radioisotope-labeled compounds or biologically active radioisotopes. Localization of such isotopes in normal or abnormal concentrations may be due to varying physiological or pathological mechanisms

  6. Cerenkov imaging.

    Science.gov (United States)

    Das, Sudeep; Thorek, Daniel L J; Grimm, Jan

    2014-01-01

    Cerenkov luminescence (CL) has been used recently in a plethora of medical applications like imaging and therapy with clinically relevant medical isotopes. The range of medical isotopes used is fairly large and expanding. The generation of in vivo light is useful since it circumvents depth limitations for excitation light. Cerenkov luminescence imaging (CLI) is much cheaper in terms of infrastructure than positron emission tomography (PET) and is particularly useful for imaging of superficial structures. Imaging can basically be done using a sensitive camera optimized for low-light conditions, and it has a better resolution than any other nuclear imaging modality. CLI has been shown to effectively diagnose disease with regularly used PET isotope ((18)F-FDG) in clinical setting. Cerenkov luminescence tomography, Cerenkov luminescence endoscopy, and intraoperative Cerenkov imaging have also been explored with positive conclusions expanding the current range of applications. Cerenkov has also been used to improve PET imaging resolution since the source of both is the radioisotope being used. Smart imaging agents have been designed based on modulation of the Cerenkov signal using small molecules and nanoparticles giving better insight of the tumor biology. © 2014 Elsevier Inc. All rights reserved.

  7. Brain imaging

    International Nuclear Information System (INIS)

    Mishkin, F.S.

    1978-01-01

    The techniques of brain imaging and results in perfusion studies and delayed images are outlined. An analysis of the advantages and disadvantages of the brain scan in a variety of common problems is discussed, especially as compared with other available procedures. Both nonneoplastic and neoplastic lesions are considered. (Auth/C.F.)

  8. Simulation of beamline alignment operations

    International Nuclear Information System (INIS)

    Annese, C; Miller, M G.

    1999-01-01

    The CORBA-based Simulator was a Laboratory Directed Research and Development (LDRD) project that applied simulation techniques to explore critical questions about distributed control systems. The simulator project used a three-prong approach that studied object-oriented distribution tools, computer network modeling, and simulation of key control system scenarios. The National Ignition Facility's (NIF) optical alignment system was modeled to study control system operations. The alignment of NIF's 192 beamlines is a large complex operation involving more than 100 computer systems and 8000 mechanized devices. The alignment process is defined by a detailed set of procedures; however, many of the steps are deterministic. The alignment steps for a poorly aligned component are similar to that of a nearly aligned component; however, additional operations/iterations are required to complete the process. Thus, the same alignment operations will require variable amounts of time to perform depending on the current alignment condition as well as other factors. Simulation of the alignment process is necessary to understand beamline alignment time requirements and how shared resources such as the Output Sensor and Target Alignment Sensor effect alignment efficiency. The simulation has provided alignment time estimates and other results based on documented alignment procedures and alignment experience gained in the laboratory. Computer communication time, mechanical hardware actuation times, image processing algorithm execution times, etc. have been experimentally determined and incorporated into the model. Previous analysis of alignment operations utilized average implementation times for all alignment operations. Resource sharing becomes rather simple to model when only average values are used. The time required to actually implement the many individual alignment operations will be quite dynamic. The simulation model estimates the time to complete an operation using

  9. Pyxis handheld polarimetric imager

    Science.gov (United States)

    Chenault, David B.; Pezzaniti, J. Larry; Vaden, Justin P.

    2016-05-01

    The instrumentation for measuring infrared polarization signatures has seen significant advancement over the last decade. Previous work has shown the value of polarimetric imagery for a variety of target detection scenarios including detection of manmade targets in clutter and detection of ground and maritime targets while recent work has shown improvements in contrast for aircraft detection and biometric markers. These data collection activities have generally used laboratory or prototype systems with limitations on the allowable amount of target motion or the sensor platform and usually require an attached computer for data acquisition and processing. Still, performance and sensitivity have been steadily getting better while size, weight, and power requirements have been getting smaller enabling polarimetric imaging for a greater or real world applications. In this paper, we describe Pyxis®, a microbolometer based imaging polarimeter that produces live polarimetric video of conventional, polarimetric, and fused image products. A polarization microgrid array integrated in the optical system captures all polarization states simultaneously and makes the system immune to motion artifacts of either the sensor or the scene. The system is battery operated, rugged, and weighs about a quarter pound, and can be helmet mounted or handheld. On board processing of polarization and fused image products enable the operator to see polarimetric signatures in real time. Both analog and digital outputs are possible with sensor control available through a tablet interface. A top level description of Pyxis® is given followed by performance characteristics and representative data.

  10. Retinal Imaging and Image Analysis

    Science.gov (United States)

    Abràmoff, Michael D.; Garvin, Mona K.; Sonka, Milan

    2011-01-01

    Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of blindness in the industrialized world that includes age-related macular degeneration, diabetic retinopathy, and glaucoma, the review is devoted to retinal imaging and image analysis methods and their clinical implications. Methods for 2-D fundus imaging and techniques for 3-D optical coherence tomography (OCT) imaging are reviewed. Special attention is given to quantitative techniques for analysis of fundus photographs with a focus on clinically relevant assessment of retinal vasculature, identification of retinal lesions, assessment of optic nerve head (ONH) shape, building retinal atlases, and to automated methods for population screening for retinal diseases. A separate section is devoted to 3-D analysis of OCT images, describing methods for segmentation and analysis of retinal layers, retinal vasculature, and 2-D/3-D detection of symptomatic exudate-associated derangements, as well as to OCT-based analysis of ONH morphology and shape. Throughout the paper, aspects of image acquisition, image analysis, and clinical relevance are treated together considering their mutually interlinked relationships. PMID:22275207

  11. Medical imaging

    CERN Document Server

    Townsend, David W

    1996-01-01

    Since the introduction of the X-ray scanner into radiology almost 25 years ago, non-invasive imaging has become firmly established as an essential tool in the diagnosis of disease. Fully three-dimensional imaging of internal organs is now possible, b and for studies which explore the functional status of the body. Powerful techniques to correlate anatomy and function are available, and scanners which combine anatomical and functional imaging in a single device are under development. Such techniques have been made possible through r ecent technological and mathematical advances. This series of lectures will review both the physical basis of medical imaging techniques using X-rays, gamma and positron emitting radiosiotopes, and nuclear magnetic resonance, and the mathematical methods used to reconstruct three-dimentional distributions from projection data. The lectures will trace the development of medical imaging from simple radiographs to the present-day non-invasive measurement of in vivo biochemistry. They ...

  12. Acoustical Imaging

    CERN Document Server

    Akiyama, Iwaki

    2009-01-01

    The 29th International Symposium on Acoustical Imaging was held in Shonan Village, Kanagawa, Japan, April 15-18, 2007. This interdisciplinary Symposium has been taking place every two years since 1968 and forms a unique forum for advanced research, covering new technologies, developments, methods and theories in all areas of acoustics. In the course of the years the volumes in the Acoustical Imaging Series have developed and become well-known and appreciated reference works. Offering both a broad perspective on the state-of-the-art in the field as well as an in-depth look at its leading edge research, this Volume 29 in the Series contains again an excellent collection of seventy papers presented in nine major categories: Strain Imaging Biological and Medical Applications Acoustic Microscopy Non-Destructive Evaluation and Industrial Applications Components and Systems Geophysics and Underwater Imaging Physics and Mathematics Medical Image Analysis FDTD method and Other Numerical Simulations Audience Researcher...

  13. Space station operations management

    Science.gov (United States)

    Cannon, Kathleen V.

    1989-01-01

    Space Station Freedom operations management concepts must be responsive to the unique challenges presented by the permanently manned international laboratory. Space Station Freedom will be assembled over a three year period where the operational environment will change as significant capability plateaus are reached. First Element Launch, Man-Tended Capability, and Permanent Manned Capability, represent milestones in operational capability that is increasing toward mature operations capability. Operations management concepts are being developed to accomodate the varying operational capabilities during assembly, as well as the mature operational environment. This paper describes operations management concepts designed to accomodate the uniqueness of Space Station Freedoom, utilizing tools and processes that seek to control operations costs.

  14. Co-registration of pre-operative CT with ex vivo surgically excised ground glass nodules to define spatial extent of invasive adenocarcinoma on in vivo imaging: a proof-of-concept study

    Energy Technology Data Exchange (ETDEWEB)

    Rusu, Mirabela [Case Western Reserve University, Department of Biomedical Engineering, Cleveland, OH (United States); GE Global Research, Niskayuna, NY (United States); Rajiah, Prabhakar [UT Southwestern Medical Center, Dallas, TX (United States); Cleveland Medical Center and Case Western Reserve University, University Hospitals, Cleveland, OH (United States); Gilkeson, Robert; Yang, Michael; Donatelli, Christopher; Linden, Philip [Cleveland Medical Center and Case Western Reserve University, University Hospitals, Cleveland, OH (United States); Thawani, Rajat; Madabhushi, Anant [Case Western Reserve University, Department of Biomedical Engineering, Cleveland, OH (United States); Jacono, Frank J. [Cleveland Medical Center and Case Western Reserve University, University Hospitals, Cleveland, OH (United States); Louis Stokes Cleveland VA Medical Center, Cleveland, OH (United States)

    2017-10-15

    To develop an approach for radiology-pathology fusion of ex vivo histology of surgically excised pulmonary nodules with pre-operative CT, to radiologically map spatial extent of the invasive adenocarcinomatous component of the nodule. Six subjects (age: 75 ± 11 years) with pre-operative CT and surgically excised ground-glass nodules (size: 22.5 ± 5.1 mm) with a significant invasive adenocarcinomatous component (>5 mm) were included. The pathologist outlined disease extent on digitized histology specimens; two radiologists and a pulmonary critical care physician delineated the entire nodule on CT (in-plane resolution: <0.8 mm, inter-slice distance: 1-5 mm). We introduced a novel reconstruction approach to localize histology slices in 3D relative to each other while using CT scan as spatial constraint. This enabled the spatial mapping of the extent of tumour invasion from histology onto CT. Good overlap of the 3D reconstructed histology and the nodule outlined on CT was observed (65.9 ± 5.2%). Reduction in 3D misalignment of corresponding anatomical landmarks on histology and CT was observed (1.97 ± 0.42 mm). Moreover, the CT attenuation (HU) distributions were different when comparing invasive and in situ regions. This proof-of-concept study suggests that our fusion method can enable the spatial mapping of the invasive adenocarcinomatous component from 2D histology slices onto in vivo CT. (orig.)

  15. Co-registration of pre-operative CT with ex vivo surgically excised ground glass nodules to define spatial extent of invasive adenocarcinoma on in vivo imaging: a proof-of-concept study

    International Nuclear Information System (INIS)

    Rusu, Mirabela; Rajiah, Prabhakar; Gilkeson, Robert; Yang, Michael; Donatelli, Christopher; Linden, Philip; Thawani, Rajat; Madabhushi, Anant; Jacono, Frank J.

    2017-01-01

    To develop an approach for radiology-pathology fusion of ex vivo histology of surgically excised pulmonary nodules with pre-operative CT, to radiologically map spatial extent of the invasive adenocarcinomatous component of the nodule. Six subjects (age: 75 ± 11 years) with pre-operative CT and surgically excised ground-glass nodules (size: 22.5 ± 5.1 mm) with a significant invasive adenocarcinomatous component (>5 mm) were included. The pathologist outlined disease extent on digitized histology specimens; two radiologists and a pulmonary critical care physician delineated the entire nodule on CT (in-plane resolution: <0.8 mm, inter-slice distance: 1-5 mm). We introduced a novel reconstruction approach to localize histology slices in 3D relative to each other while using CT scan as spatial constraint. This enabled the spatial mapping of the extent of tumour invasion from histology onto CT. Good overlap of the 3D reconstructed histology and the nodule outlined on CT was observed (65.9 ± 5.2%). Reduction in 3D misalignment of corresponding anatomical landmarks on histology and CT was observed (1.97 ± 0.42 mm). Moreover, the CT attenuation (HU) distributions were different when comparing invasive and in situ regions. This proof-of-concept study suggests that our fusion method can enable the spatial mapping of the invasive adenocarcinomatous component from 2D histology slices onto in vivo CT. (orig.)

  16. A report on digital image processing and analysis

    International Nuclear Information System (INIS)

    Singh, B.; Alex, J.; Haridasan, G.

    1989-01-01

    This report presents developments in software, connected with digital image processing and analysis in the Centre. In image processing, one resorts to either alteration of grey level values so as to enhance features in the image or resorts to transform domain operations for restoration or filtering. Typical transform domain operations like Karhunen-Loeve transforms are statistical in nature and are used for a good registration of images or template - matching. Image analysis procedures segment grey level images into images contained within selectable windows, for the purpose of estimating geometrical features in the image, like area, perimeter, projections etc. In short, in image processing both the input and output are images, whereas in image analyses, the input is an image whereas the output is a set of numbers and graphs. (author). 19 refs

  17. Four-dimensional image display for associated particle imaging

    International Nuclear Information System (INIS)

    Headley, G.; Beyerle, A.; Durkee, R.; Hurley, P.; Tunnell, L.

    1994-01-01

    Associated particle imaging (API) is a three-dimensional neutron gamma imaging technique which provides both spatial and spectral information about an unknown. A local area network consisting of a UNIX fileserver and multiple DOS workstations has been chosen to perform the data acquisition and display functions. The data are acquired with a CAMAC system, stored in list mode, and sorted on the fileserver for display on the DOS workstations. Three of the display PCs, interacting with the fileserver, provide coordinated views as the operator ''slices'' the image. The operator has a choice of: a one-dimensional shadowgram from any side, two-dimensional shadowgrams from any side; a three-dimensional view (either perspective projection or stereoscopic). A common color scheme is used to carry energy information into the spatial images. ((orig.))

  18. HFETR operation management

    International Nuclear Information System (INIS)

    Liu Rong; Yang Shuchun; Peng Jun; Zhou Shoukang

    2003-01-01

    Experiences and work methods with High Flux Engineering Test Reactor (HFETR) operation are introduced, which have been accumulated in a long period of operation, in the aspects as reactor operation, test, maintenance, operator training and incident management. It's clear that the safety operation of HFETR has been ensured, and the methods are valid. (authors)

  19. Mobile medical image retrieval

    Science.gov (United States)

    Duc, Samuel; Depeursinge, Adrien; Eggel, Ivan; Müller, Henning

    2011-03-01

    Images are an integral part of medical practice for diagnosis, treatment planning and teaching. Image retrieval has gained in importance mainly as a research domain over the past 20 years. Both textual and visual retrieval of images are essential. In the process of mobile devices becoming reliable and having a functionality equaling that of formerly desktop clients, mobile computing has gained ground and many applications have been explored. This creates a new field of mobile information search & access and in this context images can play an important role as they often allow understanding complex scenarios much quicker and easier than free text. Mobile information retrieval in general has skyrocketed over the past year with many new applications and tools being developed and all sorts of interfaces being adapted to mobile clients. This article describes constraints of an information retrieval system including visual and textual information retrieval from the medical literature of BioMedCentral and of the RSNA journals Radiology and Radiographics. Solutions for mobile data access with an example on an iPhone in a web-based environment are presented as iPhones are frequently used and the operating system is bound to become the most frequent smartphone operating system in 2011. A web-based scenario was chosen to allow for a use by other smart phone platforms such as Android as well. Constraints of small screens and navigation with touch screens are taken into account in the development of the application. A hybrid choice had to be taken to allow for taking pictures with the cell phone camera and upload them for visual similarity search as most producers of smart phones block this functionality to web applications. Mobile information access and in particular access to images can be surprisingly efficient and effective on smaller screens. Images can be read on screen much faster and relevance of documents can be identified quickly through the use of images contained in

  20. Heat transfer operators associated with quantum operations

    International Nuclear Information System (INIS)

    Aksak, C; Turgut, S

    2011-01-01

    Any quantum operation applied on a physical system is performed as a unitary transformation on a larger extended system. If the extension used is a heat bath in thermal equilibrium, the concomitant change in the state of the bath necessarily implies a heat exchange with it. The dependence of the average heat transferred to the bath on the initial state of the system can then be found from the expectation value of a Hermitian operator, which is named as the heat transfer operator (HTO). The purpose of this paper is to investigate the relation between the HTOs and the associated quantum operations. Since any given quantum operation on a system can be realized by different baths and unitaries, many different HTOs are possible for each quantum operation. On the other hand, there are also strong restrictions on the HTOs which arise from the unitarity of the transformations. The most important of these is the Landauer erasure principle. This paper is concerned with the question of finding a complete set of restrictions on the HTOs that are associated with a given quantum operation. An answer to this question has been found only for a subset of quantum operations. For erasure operations, these characterizations are equivalent to the generalized Landauer erasure principle. For the case of generic quantum operations, however, it appears that the HTOs obey further restrictions which cannot be obtained from the entropic restrictions of the generalized Landauer erasure principle.

  1. Image perception and image processing

    Energy Technology Data Exchange (ETDEWEB)

    Wackenheim, A.

    1987-01-01

    The author develops theoretical and practical models of image perception and image processing, based on phenomenology and structuralism and leading to original perception: fundamental for a positivistic approach of research work for the development of artificial intelligence that will be able in an automated system fo 'reading' X-ray pictures.

  2. Image perception and image processing

    International Nuclear Information System (INIS)

    Wackenheim, A.

    1987-01-01

    The author develops theoretical and practical models of image perception and image processing, based on phenomenology and structuralism and leading to original perception: fundamental for a positivistic approach of research work for the development of artificial intelligence that will be able in an automated system fo 'reading' X-ray pictures. (orig.) [de

  3. Retinal imaging and image analysis

    NARCIS (Netherlands)

    Abramoff, M.D.; Garvin, Mona K.; Sonka, Milan

    2010-01-01

    Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of

  4. Animal Feeding Operations

    Science.gov (United States)

    ... type=”submit” value=”Submit” /> Healthy Water Home Animal Feeding Operations Recommend on Facebook Tweet Share Compartir ... of Concentrated Animal Feeding Operations (CAFOs) What are Animal Feeding Operations (AFOs)? According to the United States ...

  5. COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    Dominique Lafon

    2011-05-01

    Full Text Available The goal of this article is to present specific capabilities and limitations of the use of color digital images in a characterization process. The whole process is investigated, from the acquisition of digital color images to the analysis of the information relevant to various applications in the field of material characterization. A digital color image can be considered as a matrix of pixels with values expressed in a vector-space (commonly 3 dimensional space whose specificity, compared to grey-scale images, is to ensure a coding and a representation of the output image (visualisation printing that fits the human visual reality. In a characterization process, it is interesting to regard color image attnbutes as a set of visual aspect measurements on a material surface. Color measurement systems (spectrocolorimeters, colorimeters and radiometers and cameras use the same type of light detectors: most of them use Charge Coupled Devices sensors. The difference between the two types of color data acquisition systems is that color measurement systems provide a global information of the observed surface (average aspect of the surface: the color texture is not taken into account. Thus, it seems interesting to use imaging systems as measuring instruments for the quantitative characterization of the color texture.

  6. Conduct of operations: establishing operational focus and setting operational standards

    International Nuclear Information System (INIS)

    Lane, L.; McGuigan, K.

    1998-01-01

    Due to the nature of our business, we have often tended to focus on the technological aspects of the nuclear industry. The focus of this paper is directed towards the importance of addressing the people skills, attitudes, and 'culture' within, and surrounding, our facilities as key areas of improvement. Within Ontario Hydro Nuclear (OLIN) we have developed the terminology 'event free' operation and 'event free' culture. 'Event Free' recognizes errors as a part of human performance. 'Event Free' takes into account human weaknesses, and provides tools (such as standards) to manage, control, and mitigate errors. In essence, 'Event Free' encompasses two concepts: 1. Prevent errors from occurring; 2. If an error is made, catch it before it can affect safe operation of the facility, learn from the error, and ensure that it does not happen again. In addressing these business realities, Ontario Hydro has identified a number of key support mechanisms and corresponding performance standards that are essential for achieving operating excellence and an 'event free' business culture. This paper will discuss two operational aspects of an 'event free' culture, the first being a set of expectations to enhance the culture, and the second an example of cultural change: 1. Operating Standards - establishing clear expectations for human performance in operating staff; 2. Operational Focus - the understanding that, as a nuclear worker, you should consider every task, activity, in fact everything you do in this business, for the potential to affect safe and reliable operation of a nuclear facility. Note that although the term 'Operational' appears in the title, this concept applies to every individual in the nuclear business, from the cleaner, to the Board of Directors, to the external supplier. (author)

  7. A Versatile Image Processor For Digital Diagnostic Imaging And Its Application In Computed Radiography

    Science.gov (United States)

    Blume, H.; Alexandru, R.; Applegate, R.; Giordano, T.; Kamiya, K.; Kresina, R.

    1986-06-01

    In a digital diagnostic imaging department, the majority of operations for handling and processing of images can be grouped into a small set of basic operations, such as image data buffering and storage, image processing and analysis, image display, image data transmission and image data compression. These operations occur in almost all nodes of the diagnostic imaging communications network of the department. An image processor architecture was developed in which each of these functions has been mapped into hardware and software modules. The modular approach has advantages in terms of economics, service, expandability and upgradeability. The architectural design is based on the principles of hierarchical functionality, distributed and parallel processing and aims at real time response. Parallel processing and real time response is facilitated in part by a dual bus system: a VME control bus and a high speed image data bus, consisting of 8 independent parallel 16-bit busses, capable of handling combined up to 144 MBytes/sec. The presented image processor is versatile enough to meet the video rate processing needs of digital subtraction angiography, the large pixel matrix processing requirements of static projection radiography, or the broad range of manipulation and display needs of a multi-modality diagnostic work station. Several hardware modules are described in detail. For illustrating the capabilities of the image processor, processed 2000 x 2000 pixel computed radiographs are shown and estimated computation times for executing the processing opera-tions are presented.

  8. Saxton Transportation Operations Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Saxton Transportation Operations Laboratory (Saxton Laboratory) is a state-of-the-art facility for conducting transportation operations research. The laboratory...

  9. Multi-Source Image Analysis.

    Science.gov (United States)

    1979-12-01

    These collections were taken to show the advantages made available to the inter- preter. In a military operation, however, often little or no in- situ ...The large body of water labeled "W" on each image represents the Agua Hedionda lagoon. East of the lagoon the area is primarily agricultural with a...power plant located in the southeast corner of the image. West of the Agua Hedionda lagoon is Carlsbad, California. Damp ground is labelled "Dg" on the

  10. Image registration assessment in radiotherapy image guidance based on control chart monitoring.

    Science.gov (United States)

    Xia, Wenyao; Breen, Stephen L

    2018-04-01

    Image guidance with cone beam computed tomography in radiotherapy can guarantee the precision and accuracy of patient positioning prior to treatment delivery. During the image guidance process, operators need to take great effort to evaluate the image guidance quality before correcting a patient's position. This work proposes an image registration assessment method based on control chart monitoring to reduce the effort taken by the operator. According to the control chart plotted by daily registration scores of each patient, the proposed method can quickly detect both alignment errors and image quality inconsistency. Therefore, the proposed method can provide a clear guideline for the operators to identify unacceptable image quality and unacceptable image registration with minimal effort. Experimental results demonstrate that by using control charts from a clinical database of 10 patients undergoing prostate radiotherapy, the proposed method can quickly identify out-of-control signals and find special cause of out-of-control registration events.

  11. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Surgical Skills for Exposure in Trauma Advanced Trauma Life Support Advanced Trauma Operative Management Basic Endovascular Skills for Trauma Disaster Management and Emergency ...

  12. Multi-channel medical imaging system

    Science.gov (United States)

    Frangioni, John V

    2013-12-31

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in the subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  13. Buried object detection in GPR images

    Science.gov (United States)

    Paglieroni, David W; Chambers, David H; Bond, Steven W; Beer, W. Reginald

    2014-04-29

    A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes the return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

  14. Near-infrared spectroscopic tissue imaging for medical applications

    Science.gov (United States)

    Demos, Stavros [Livermore, CA; Staggs, Michael C [Tracy, CA

    2006-12-12

    Near infrared imaging using elastic light scattering and tissue autofluorescence are explored for medical applications. The approach involves imaging using cross-polarized elastic light scattering and tissue autofluorescence in the Near Infra-Red (NIR) coupled with image processing and inter-image operations to differentiate human tissue components.

  15. Multispectral system for medical fluorescence imaging

    International Nuclear Information System (INIS)

    Andersson, P.S.; Montan, S.; Svanberg, S.

    1987-01-01

    The principles of a powerful multicolor imaging system for tissue fluorescence diagnostics are discussed. Four individually spectrally filtered images are formed on a matrix detector by means of a split-mirror arrangement. The four images are processed in a computer, pixel by pixel, by means of mathematical operations, leading to an optimized contrast image, which enhances a selected feature. The system is being developed primarily for medical fluorescence imaging, but has wide applications in fluorescence, reflectance, and transmission monitoring related to a wide range of industrial and environmental problems. The system operation is described for the case of linear imaging on a diode array detector. Laser-induced fluorescence is used for cancer tumor and arteriosclerotic plaque demarcation using the contrast enhancement capabilities of this imaging system. Further examples of applications include fluorescing minerals and flames

  16. Image analysis

    International Nuclear Information System (INIS)

    Berman, M.; Bischof, L.M.; Breen, E.J.; Peden, G.M.

    1994-01-01

    This paper provides an overview of modern image analysis techniques pertinent to materials science. The usual approach in image analysis contains two basic steps: first, the image is segmented into its constituent components (e.g. individual grains), and second, measurement and quantitative analysis are performed. Usually, the segmentation part of the process is the harder of the two. Consequently, much of the paper concentrates on this aspect, reviewing both fundamental segmentation tools (commonly found in commercial image analysis packages) and more advanced segmentation tools. There is also a review of the most widely used quantitative analysis methods for measuring the size, shape and spatial arrangements of objects. Many of the segmentation and analysis methods are demonstrated using complex real-world examples. Finally, there is a discussion of hardware and software issues. 42 refs., 17 figs

  17. Medical imaging

    International Nuclear Information System (INIS)

    Loshkajian, A.

    2000-01-01

    This didactical book presents the medical imaging techniques: radiography, scanner, nuclear magnetic resonance (NMR). Examples are given for the most common pathologies in all domains of medicine. (J.S.)

  18. Separable quadratic stochastic operators

    International Nuclear Information System (INIS)

    Rozikov, U.A.; Nazir, S.

    2009-04-01

    We consider quadratic stochastic operators, which are separable as a product of two linear operators. Depending on properties of these linear operators we classify the set of the separable quadratic stochastic operators: first class of constant operators, second class of linear and third class of nonlinear (separable) quadratic stochastic operators. Since the properties of operators from the first and second classes are well known, we mainly study the properties of the operators of the third class. We describe some Lyapunov functions of the operators and apply them to study ω-limit sets of the trajectories generated by the operators. We also compare our results with known results of the theory of quadratic operators and give some open problems. (author)

  19. Neurosurgical operating computerized tomographic scanner system

    International Nuclear Information System (INIS)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi.

    1988-01-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place. (author)

  20. Hemorrhage detection in MRI brain images using images features

    Science.gov (United States)

    Moraru, Luminita; Moldovanu, Simona; Bibicu, Dorin; Stratulat (Visan), Mirela

    2013-11-01

    The abnormalities appear frequently on Magnetic Resonance Images (MRI) of brain in elderly patients presenting either stroke or cognitive impairment. Detection of brain hemorrhage lesions in MRI is an important but very time-consuming task. This research aims to develop a method to extract brain tissue features from T2-weighted MR images of the brain using a selection of the most valuable texture features in order to discriminate between normal and affected areas of the brain. Due to textural similarity between normal and affected areas in brain MR images these operation are very challenging. A trauma may cause microstructural changes, which are not necessarily perceptible by visual inspection, but they could be detected by using a texture analysis. The proposed analysis is developed in five steps: i) in the pre-processing step: the de-noising operation is performed using the Daubechies wavelets; ii) the original images were transformed in image features using the first order descriptors; iii) the regions of interest (ROIs) were cropped from images feature following up the axial symmetry properties with respect to the mid - sagittal plan; iv) the variation in the measurement of features was quantified using the two descriptors of the co-occurrence matrix, namely energy and homogeneity; v) finally, the meaningful of the image features is analyzed by using the t-test method. P-value has been applied to the pair of features in order to measure they efficacy.

  1. Image Sensor

    OpenAIRE

    Jerram, Paul; Stefanov, Konstantin

    2017-01-01

    An image sensor of the type for providing charge multiplication by impact ionisation has plurality of multiplication elements. Each element is arranged to receive charge from photosensitive elements of an image area and each element comprises a sequence of electrodes to move charge along a transport path. Each of the electrodes has an edge defining a boundary with a first electrode, a maximum width across the charge transport path and a leading edge that defines a boundary with a second elect...

  2. Brain imaging

    International Nuclear Information System (INIS)

    Greenfield, L.D.; Bennett, L.R.

    1976-01-01

    Imaging with radionuclides should be used in a complementary fashion with other neuroradiologic techniques. It is useful in the early detection and evaluation of intracranial neoplasm, cerebrovascular accident and abscess, and in postsurgical follow-up. Cisternography yields useful information about the functional status of cerebrospinal fluid pathways. Computerized axial tomography is a new technique of great promise that produced a cross-sectional image of the brain

  3. Emerging images

    KAUST Repository

    Mitra, Niloy J.

    2009-01-01

    Emergence refers to the unique human ability to aggregate information from seemingly meaningless pieces, and to perceive a whole that is meaningful. This special skill of humans can constitute an effective scheme to tell humans and machines apart. This paper presents a synthesis technique to generate images of 3D objects that are detectable by humans, but difficult for an automatic algorithm to recognize. The technique allows generating an infinite number of images with emerging figures. Our algorithm is designed so that locally the synthesized images divulge little useful information or cues to assist any segmentation or recognition procedure. Therefore, as we demonstrate, computer vision algorithms are incapable of effectively processing such images. However, when a human observer is presented with an emergence image, synthesized using an object she is familiar with, the figure emerges when observed as a whole. We can control the difficulty level of perceiving the emergence effect through a limited set of parameters. A procedure that synthesizes emergence images can be an effective tool for exploring and understanding the factors affecting computer vision techniques. © 2009 ACM.

  4. Detecting aircrafts from satellite images using saliency and conical ...

    Indian Academy of Sciences (India)

    Samik Banerjee

    automatically detect all kinds of interesting targets in satellite images. .... which is used for text and image categorization, has been also introduced for object ...... 3.4 GHz processor, 32 GB RAM and Windows 7 (64 bit). Operating System. 6.

  5. Underwater laser imaging system (UWLIS)

    Energy Technology Data Exchange (ETDEWEB)

    DeLong, M. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Practical limitations with underwater imaging systems area reached when the noise in the back scattered radiation generated in the water between the imaging system and the target obscures the spatial contrast and resolution necessary for target discovery and identification. The advent of high power lasers operating in the blue-green portion of the visible spectrum (oceanic transmission window) has led to improved experimental illumination systems for underwater imaging. Range-gated and synchronously scanned devices take advantage of the unique temporal and spatial coherence properties of laser radiation, respectively, to overcome the deleterious effects of common volume back scatter.

  6. RESEARCH OF REGISTRATION APPROACHES OF THERMAL INFRARED IMAGES AND INTENSITY IMAGES OF POINT CLOUD

    Directory of Open Access Journals (Sweden)

    L. Liu

    2017-09-01

    Full Text Available In order to realize the analysis of thermal energy of the objects in 3D vision, the registration approach of thermal infrared images and TLS (Terrestrial Laser Scanner point cloud was studied. The original data was pre-processed. For the sake of making the scale and brightness contrast of the two kinds of data meet the needs of basic matching, the intensity image of point cloud was produced and projected to spherical coordinate system, histogram equalization processing was done for thermal infrared image.This paper focused on the research of registration approaches of thermal infrared images and intensity images of point cloud based on SIFT,EOH-SIFT and PIIFD operators. The latter of which is usually used for medical image matching with different spectral character. The comparison results of the experiments showed that PIIFD operator got much more accurate feature point correspondences compared to SIFT and EOH-SIFT operators. The thermal infrared image and intensity image also have ideal overlap results by quadratic polynomial transformation. Therefore, PIIFD can be used as the basic operator for the registration of thermal infrared images and intensity images, and the operator can also be further improved by incorporating the iteration method.

  7. Intelligent distributed medical image management

    Science.gov (United States)

    Garcia, Hong-Mei C.; Yun, David Y.

    1995-05-01

    The rapid advancements in high performance global communication have accelerated cooperative image-based medical services to a new frontier. Traditional image-based medical services such as radiology and diagnostic consultation can now fully utilize multimedia technologies in order to provide novel services, including remote cooperative medical triage, distributed virtual simulation of operations, as well as cross-country collaborative medical research and training. Fast (efficient) and easy (flexible) retrieval of relevant images remains a critical requirement for the provision of remote medical services. This paper describes the database system requirements, identifies technological building blocks for meeting the requirements, and presents a system architecture for our target image database system, MISSION-DBS, which has been designed to fulfill the goals of Project MISSION (medical imaging support via satellite integrated optical network) -- an experimental high performance gigabit satellite communication network with access to remote supercomputing power, medical image databases, and 3D visualization capabilities in addition to medical expertise anywhere and anytime around the country. The MISSION-DBS design employs a synergistic fusion of techniques in distributed databases (DDB) and artificial intelligence (AI) for storing, migrating, accessing, and exploring images. The efficient storage and retrieval of voluminous image information is achieved by integrating DDB modeling and AI techniques for image processing while the flexible retrieval mechanisms are accomplished by combining attribute- based and content-based retrievals.

  8. Markov Processes in Image Processing

    Science.gov (United States)

    Petrov, E. P.; Kharina, N. L.

    2018-05-01

    Digital images are used as an information carrier in different sciences and technologies. The aspiration to increase the number of bits in the image pixels for the purpose of obtaining more information is observed. In the paper, some methods of compression and contour detection on the basis of two-dimensional Markov chain are offered. Increasing the number of bits on the image pixels will allow one to allocate fine object details more precisely, but it significantly complicates image processing. The methods of image processing do not concede by the efficiency to well-known analogues, but surpass them in processing speed. An image is separated into binary images, and processing is carried out in parallel with each without an increase in speed, when increasing the number of bits on the image pixels. One more advantage of methods is the low consumption of energy resources. Only logical procedures are used and there are no computing operations. The methods can be useful in processing images of any class and assignment in processing systems with a limited time and energy resources.

  9. Imaging of Nuclear Weapon Trainers

    Energy Technology Data Exchange (ETDEWEB)

    Schwellenbach, David [National Security Technologies, LLC. (NSTec), Mercury, NV (United States)

    2017-12-06

    The Configurable Muon Tracker (CMT) is an adaptation of the existing drift tube detector commercially available from Decision Sciences International Corporation (DSIC). NSTec engineered the CMT around commercially available drift tube assemblies to make a detector that is more versatile than previous drift tube assemblies. The CMT became operational in February 2013. Traditionally, cosmic-ray muon trackers rely on near-vertical trajectory muons for imaging. Since there are scenarios where imaging using vertical trajectory muons is not practical, NSTec designed the CMT specifically for quick configurability to track muons from any trajectory. The CMT was originally designed to be changed from vertical imaging mode to horizontal imaging mode in a few hours with access to a crane or other lifting equipment. In FY14, locations for imaging weapon trainers and SNM were identified and it was determined that lifting equipment would not typically be available in experimental areas. The CMT was further modified and a portable lifting system was developed to allow reconfiguration of the CMT without access to lifting equipment at the facility. This system was first deployed at Los Alamos National Laboratory’s W-division, where several trainers were imaged in both horizontal and vertical modes. Real-time images have been compared in both modes showing that imaging can be done in both modes with the expected longer integration time for horizontal mode. Further imaging and post processing of the data is expected to continue into early FY15.

  10. International co-operation

    International Nuclear Information System (INIS)

    1998-01-01

    In this part the are reviewed: Co-operation with IAEA; Participation of the Slovakia on the 41 st session of the General Conference; The comprehensive Nuclear-Test-Ban Treaty Organization; Co-operation with the Organization for Economic Co-operation and Development; co-operation with the European Commission; Fulfillment of obligations resulting from the international contracting documents

  11. Biomedical programs operations plans

    Science.gov (United States)

    Walbrecher, H. F.

    1974-01-01

    Operational guidelines for the space shuttle life sciences payloads are presented. An operational assessment of the medical experimental altitude test for Skylab, and Skylab life sciences documentation are discussed along with the operations posture and collection of space shuttle operational planning data.

  12. IMDISP - INTERACTIVE IMAGE DISPLAY PROGRAM

    Science.gov (United States)

    Martin, M. D.

    1994-01-01

    screen at once, the image can be "subsampled." For example, if the image were subsampled by a factor of 2, every other pixel from every other line would be displayed, starting from the upper left corner of the image. Any positive integer may be used for subsampling. The user may produce a histogram of an image file, which is a graph showing the number of pixels per DN value, or per range of DN values, for the entire image. IMDISP can also plot the DN value versus pixels along a line between two points on the image. The user can "stretch" or increase the contrast of an image by specifying low and high DN values; all pixels with values lower than the specified "low" will then become black, and all pixels higher than the specified "high" value will become white. Pixels between the low and high values will be evenly shaded between black and white. IMDISP is written in a modular form to make it easy to change it to work with different display devices or on other computers. The code can also be adapted for use in other application programs. There are device dependent image display modules, general image display subroutines, image I/O routines, and image label and command line parsing routines. The IMDISP system is written in C-language (94%) and Assembler (6%). It was implemented on an IBM PC with the MS DOS 3.21 operating system. IMDISP has a memory requirement of about 142k bytes. IMDISP was developed in 1989 and is a copyrighted work with all copyright vested in NASA. Additional planetary images can be obtained from the National Space Science Data Center at (301) 286-6695.

  13. 3D ultrasound imaging for prosthesis fabrication and diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, A.K.; Bow, W.J.; Strong, D.S. [and others

    1995-06-01

    The fabrication of a prosthetic socket for a below-the-knee amputee requires knowledge of the underlying bone structure in order to provide pressure relief for sensitive areas and support for load bearing areas. The goal is to enable the residual limb to bear pressure with greater ease and utility. Conventional methods of prosthesis fabrication are based on limited knowledge about the patient`s underlying bone structure. A 3D ultrasound imaging system was developed at Sandia National Laboratories. The imaging system provides information about the location of the bones in the residual limb along with the shape of the skin surface. Computer assisted design (CAD) software can use this data to design prosthetic sockets for amputees. Ultrasound was selected as the imaging modality. A computer model was developed to analyze the effect of the various scanning parameters and to assist in the design of the overall system. The 3D ultrasound imaging system combines off-the-shelf technology for image capturing, custom hardware, and control and image processing software to generate two types of image data -- volumetric and planar. Both volumetric and planar images reveal definition of skin and bone geometry with planar images providing details on muscle fascial planes, muscle/fat interfaces, and blood vessel definition. The 3D ultrasound imaging system was tested on 9 unilateral below-the- knee amputees. Image data was acquired from both the sound limb and the residual limb. The imaging system was operated in both volumetric and planar formats. An x-ray CT (Computed Tomography) scan was performed on each amputee for comparison. Results of the test indicate beneficial use of ultrasound to generate databases for fabrication of prostheses at a lower cost and with better initial fit as compared to manually fabricated prostheses.

  14. Composite operators in QCD

    International Nuclear Information System (INIS)

    Sonoda, Hidenori

    1992-01-01

    We give a formula for the derivatives of a correlation function of composite operators with respect to the parameters (i.e. the strong fine structure constant and the quark mass) of QCD in four- dimensional euclidean space. The formula is given as spatial integration of the operator conjugate to a parameter. The operator product of a composite operator and a conjugate operator has an unintegrable part, and the formula requires divergent subtractions. By imposing consistency conditions we drive a relation between the anomalous dimensions of the composite operators and the unintegrable part of the operator product coefficients. (orig.)

  15. The AECL operator companion

    International Nuclear Information System (INIS)

    Lupton, L.R.; Anderson, L.L.; Basso, R.A.J.

    1989-11-01

    As CANDU plants become more complex, and are operated under tighter constraints and for longer periods between outages, plant operations staff will have to absorb more information to correctly and rapidly respond to upsets. A development program is underway at AECL to use expert systems and interactive media tools to assist operations staff of existing and future CANDU plants. The complete system for plant information access and display, on-line advice and diagnosis, and interactive operating procedures is called the Operator Companion. A prototype, consisting of operator consoles, expert systems and simulation modules in a distributed architecture, is currently being developed to demonstrate the concepts of the Operator Companion

  16. PC image processing

    International Nuclear Information System (INIS)

    Hwa, Mok Jin Il; Am, Ha Jeng Ung

    1995-04-01

    This book starts summary of digital image processing and personal computer, and classification of personal computer image processing system, digital image processing, development of personal computer and image processing, image processing system, basic method of image processing such as color image processing and video processing, software and interface, computer graphics, video image and video processing application cases on image processing like satellite image processing, color transformation of image processing in high speed and portrait work system.

  17. Three dimensional image alignment, registration and fusion

    International Nuclear Information System (INIS)

    Treves, S.T.; Mitchell, K.D.; Habboush, I.H.

    1998-01-01

    Combined assessment of three dimensional anatomical and functional images (SPECT, PET, MRI, CT) is useful to determine the nature and extent of lesions in many parts of the body. Physicians principally rely on their spatial sense of mentally re-orient and overlap images obtained with different imaging modalities. Objective methods that enable easy and intuitive image registration can help the physician arrive at more optimal diagnoses and better treatment decisions. This review describes a simple, intuitive and robust image registration approach developed in our laboratory. It differs from most other registration techniques in that it allows the user to incorporate all of the available information within the images in the registration process. This method takes full advantage of the ability of knowledgeable operators to achieve image registration and fusion using an intuitive interactive visual approach. It can register images accurately and quickly without the use of elaborate mathematical modeling or optimization techniques. The method provides the operator with tools to manipulate images in three dimensions, including visual feedback techniques to assess the accuracy of registration (grids, overlays, masks, and fusion of images in different colors). Its application is not limited to brain imaging and can be applied to images from any region in the body. The overall effect is a registration algorithm that is easy to implement and can achieve accuracy on the order of one pixel

  18. Elementary operators on self-adjoint operators

    Science.gov (United States)

    Molnar, Lajos; Semrl, Peter

    2007-03-01

    Let H be a Hilbert space and let and be standard *-operator algebras on H. Denote by and the set of all self-adjoint operators in and , respectively. Assume that and are surjective maps such that M(AM*(B)A)=M(A)BM(A) and M*(BM(A)B)=M*(B)AM*(B) for every pair , . Then there exist an invertible bounded linear or conjugate-linear operator and a constant c[set membership, variant]{-1,1} such that M(A)=cTAT*, , and M*(B)=cT*BT, .

  19. Electromagnetic brain imaging

    International Nuclear Information System (INIS)

    Sekihara, Kensuke

    2008-01-01

    Present imaging methods of cerebral neuro-activity like brain functional MRI and positron emission tomography (PET) secondarily measure only average activities within a time of the second-order (low time-resolution). In contrast, the electromagnetic brain imaging (EMBI) directly measures the faint magnetic field (10 -12 -10 -13 T) yielded by the cerebral activity with use of multiple arrayed sensors equipped on the head surface within a time of sub-millisecond order (high time-resolution). The sensor array technology to find the signal source from the measured data is common in wide areas like signal procession for radar, sonar, and epicenter detection by seismic wave. For estimating and reconstructing the active region in the brain in EMBI, the efficient method must be developed and this paper describes the direct and inverse problems concerned in signal and image processions of EMBI. The direct problem involves the cerebral magnetic field/lead field matrix and inverse problem for reconstruction of signal source, the MUSIC (multiple signal classification) algorithm, GLRT (generalized likelihood ratio test) scan, and adaptive beamformer. As an example, given are results of magnetic intensity changes (unit, fT) in the somatosensory cortex vs time (msec) measured by 160 sensors and of images reconstructed from EMBI and MRI during electric muscle afferent input from the hand. The real-time imaging is thus possible with EMBI and extremely, the EMBI image, the real-time cerebral signals, can inversely operate a machine, of which application directs toward the brain/machine interface development. (R.T.)

  20. Identities for generalized fractional integral operators associated ...

    African Journals Online (AJOL)

    In this present work an attempt has been made to define two generalized fractional integral operators associated with products of analogues to Dirichlet averages and special functions. Discussions on the different aspects of the obtained results have been followed by utilization in finding out the images of multivariate ...

  1. Reduction operator for wide-SIMDs reconsidered

    NARCIS (Netherlands)

    Waeijen, L.J.W.; She, D.; Corporaal, H.; He, Y.

    2014-01-01

    It has been shown that wide Single Instruction Multiple Data architectures (wide-SIMDs) can achieve high energy efficiency, especially in domains such as image and vision processing. In these and various other application domains, reduction is a frequently encountered operation, where multiple input

  2. Gamma-Ray Imaging Probes.

    Science.gov (United States)

    Wild, Walter James

    1988-12-01

    External nuclear medicine diagnostic imaging of early primary and metastatic lung cancer tumors is difficult due to the poor sensitivity and resolution of existing gamma cameras. Nonimaging counting detectors used for internal tumor detection give ambiguous results because distant background variations are difficult to discriminate from neighboring tumor sites. This suggests that an internal imaging nuclear medicine probe, particularly an esophageal probe, may be advantageously used to detect small tumors because of the ability to discriminate against background variations and the capability to get close to sites neighboring the esophagus. The design, theory of operation, preliminary bench tests, characterization of noise behavior and optimization of such an imaging probe is the central theme of this work. The central concept lies in the representation of the aperture shell by a sequence of binary digits. This, coupled with the mode of operation which is data encoding within an axial slice of space, leads to the fundamental imaging equation in which the coding operation is conveniently described by a circulant matrix operator. The coding/decoding process is a classic coded-aperture problem, and various estimators to achieve decoding are discussed. Some estimators require a priori information about the object (or object class) being imaged; the only unbiased estimator that does not impose this requirement is the simple inverse-matrix operator. The effects of noise on the estimate (or reconstruction) is discussed for general noise models and various codes/decoding operators. The choice of an optimal aperture for detector count times of clinical relevance is examined using a statistical class-separability formalism.

  3. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  4. Fast imaging

    International Nuclear Information System (INIS)

    Wehrli, F.W.; Altas, S.W.

    1991-01-01

    This paper reports on MRI which has evolved rapidly and promises to continue to do so. The diagnostic armamentarium, as a result, has increased dramatically over recent years, which has necessitated constant interactions between clinicians, physicists, and biochemists. Pulse sequence design, coupled with advances in other software and hardware technology, offers practical improvements in scanning and image quality. Perhaps more importantly, these same advances hold promise for MRI to become, in addition to its traditional role as a morphological imaging technique, a functional imaging modality. The attractiveness of this prospect is that for the first time, a high-resolution technique has been shown to have the potential to provide both types of information from a single integrated examination, which promises to generate important insights into normal physiology as well as the natural history of pathophysiologic states

  5. Operation planning device

    International Nuclear Information System (INIS)

    Watanabe, Takashi; Odakawa, Naoto; Erikuchi, Makoto; Okada, Masayuki; Koizumi, Atsuhiko.

    1996-01-01

    The device of the present invention provides a device suitable for monitoring a reactor core state and operation replanning in terms of reactor operation. Namely, (1) an operation result difference judging means judges that replanning is necessary when the operation results deviates from the operation planning, (2) an operation replanning rule data base storing means stores a deviation key which shows various kinds of states where the results deviate from the planning and a rule for replanning for returning to the operation planning on every deviating key, (3) an operation replanning means forms a new operation planning in accordance with the rule which is retrieved based on the deviation key, (4) an operation planning optimizing rule data base storing means evaluates the reformed planning and stores it on every evaluation item, (5) an operation planning optimization means correct the operation planning data so as to be optimized when the evaluation of the means (4) is less than a reference value, and (6) an operation planning display means edits adaptable operation planning data and the result of the evaluation and displays them. (I.S.)

  6. Ultrasound Imaging. Chapter 13

    Energy Technology Data Exchange (ETDEWEB)

    Lacefield, J. C. [University of Western Ontario, London (Canada)

    2014-09-15

    In the conventional method of ultrasonography, images are acquired in reflection, or pulse echo, mode. An array of small piezoelectric elements transmits a focused pulse along a specified line of sight known as a scan line. Echoes returning from the tissue are received by the same array, focused via the delay-and-sum beam forming process reviewed in Section 13.2, and demodulated to obtain the magnitude, or envelope, of the echo signal. The scanner measures the arrival time of the echoes relative to the time the pulse was transmitted and maps the arrival time to the distance from the array, using an assumed speed of sound. The earliest ultrasound systems would display the result of a single pulse acquisition in 1-D A-mode (amplitude mode) format by plotting echo magnitude as a function of distance. A 2-D or 3-D B-mode (brightness mode) image is acquired by performing a large number of pulse echo acquisitions, incrementally increasing the scan line direction between each pulse echo operation, to sweep out a 2-D or 3-D field of view (FOV). The term B-mode imaging reflects the fact that the echo magnitude from each point in the FOV is mapped to the grey level, or brightness, of the corresponding pixel in the image.

  7. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... to Choosing a Surgical Residency Education Modules Practice Management Workshops Patients and Family Patient Education Patient Education ... Trauma Advanced Trauma Life Support Advanced Trauma Operative Management Basic Endovascular Skills for Trauma Disaster Management and ...

  8. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Congress Educational Program Events and Special Activities Resources Housing and Travel Exhibitors Media Information Clinical Congress 2017 ... Surgical Skills for Exposure in Trauma Advanced Trauma Life Support Advanced Trauma Operative Management Basic Endovascular Skills ...

  9. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... 25- and 50-Year Fellows Recognition Surgical History Group Icons in Surgery Archives Catalog Additional Resources Contact ... for after the operation including review of attached equipment and ways for you to actively participate to ...

  10. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... at ACS ACS and Veterans Diversity at ACS ... and Family Contact My Profile Shop ( 0 ) Cart Donate American College of Surgeons Education Patients and Family Skills Programs Your Lung Operation ...

  11. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Surgeon Specific Registry Trauma Education Trauma Education Trauma Education Advanced Surgical Skills for Exposure in Trauma Advanced Trauma Life Support Advanced Trauma Operative Management Basic Endovascular Skills for Trauma Disaster Management and Emergency ...

  12. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Education Trauma Education Achieving Zero Preventable Deaths Trauma Systems Conference Advanced Surgical Skills for Exposure in Trauma Advanced Trauma Life Support Advanced Trauma Operative Management Basic Endovascular Skills for Trauma Disaster Management and ...

  13. Nonlocal Operational Calculi for Dunkl Operators

    Directory of Open Access Journals (Sweden)

    Ivan H. Dimovski

    2009-03-01

    Full Text Available The one-dimensional Dunkl operator $D_k$ with a non-negative parameter $k$, is considered under an arbitrary nonlocal boundary value condition. The right inverse operator of $D_k$, satisfying this condition is studied. An operational calculus of Mikusinski type is developed. In the frames of this operational calculi an extension of the Heaviside algorithm for solution of nonlocal Cauchy boundary value problems for Dunkl functional-differential equations $P(D_ku = f$ with a given polynomial $P$ is proposed. The solution of these equations in mean-periodic functions reduces to such problems. Necessary and sufficient condition for existence of unique solution in mean-periodic functions is found.

  14. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Mentoring for Excellence in Trauma Surgery Advanced Trauma Life Support Verification, Review, and Consultation Program for Hospitals ... Surgical Skills for Exposure in Trauma Advanced Trauma Life Support Advanced Trauma Operative Management Basic Endovascular Skills ...

  15. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Stay Up to Date with ACS Association Management Jobs Events Find a Surgeon Patients and Family Contact My Profile Shop ( 0 ) Cart Donate American College of Surgeons Education Patients and Family Skills Programs Your Lung Operation ...

  16. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Disaster Management and Emergency Preparedness Rural Trauma Team Development Course Trauma Evaluation and Management Trauma CME The ... for after the operation including review of attached equipment and ways for you to actively participate to ...

  17. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Up to Date with ACS Association Management JACS Jobs Events Find a Surgeon Patients and Family Contact My Profile Shop ( 0 ) Cart Donate American College of Surgeons Education Patients and Family Skills Programs Your Lung Operation ...

  18. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... ACS ACS and Veterans Diversity at ACS ... and Family Contact My Profile Shop ( 0 ) Cart Donate American College of Surgeons Education Patients and Family Skills Programs Your Lung Operation ...

  19. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Online Guide to Choosing a Surgical Residency Practice Management Workshops Patients and Family Patient Education Patient Education ... Trauma Advanced Trauma Life Support Advanced Trauma Operative Management Basic Endovascular Skills for Trauma Disaster Management and ...

  20. Incompatible Images

    DEFF Research Database (Denmark)

    Sassene, Michel J.; Hertzum, Morten

    2008-01-01

    is, however, based on a taken-for-granted image of asthmatics as, per se, striving to be symptom-free. This image is incompatible with interviewed asthmatics' day-to-day performances of their asthma, and renders invisible (a) that their asthma performances emphasize an economy of good passages...... and of feeling capable, (b) that they achieve the objective of feeling capable in quite different ways, and (c) that feeling capable does not per se equal being symptom-free all the time. To attain long-term use of self-management systems and other patient-centred e-health systems, such systems must acknowledge...