WorldWideScience

Sample records for wire scanner system

  1. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  2. Software Development for a CompactRIO-Based Wire Scanner Control and Data Acquisition System

    International Nuclear Information System (INIS)

    Sedillo, James Daniel

    2012-01-01

    The Beam Diagnostics and Instrumentation Team at the Los Alamos Neutron Science Center is developing a wire scanner data acquisition and control system with a National Instrument's compactRIO at its core. For this application, the compactRIO controller not only requires programming the FPGA and RT computer internal to the compactRIO, but also requires programming a client computer and a touch panel display. This article will summarize the hardware interfaces and describe the software design approach utilized for programming and interfacing the four systems together in order to fulfill the design requirements and promote reliable interoperability.

  3. A high resolution wire scanner beam profile monitor with a microprocessor data acquisition system

    International Nuclear Information System (INIS)

    Cutler, R.I.; Mohr, D.L.; Whittaker, J.K.; Yoder, N.R.

    1983-01-01

    A beam profile monitor has been constructed for the NBS-LANL Racetrack Microtron. The monitor consists of two perpendicular 30 μm diameter carbon wires that are driven through an electron beam by a pneumatic actuator. A long-lifetime, electroformed nickel bellows is used for the linear-motion vacuum feedthrough. Secondary emission current from the wires and a signal from a transducer measuring the position of the wires are simultaneously digitized by a microprocessor to yield beam current density profiles in two dimensions. The wire scanner is designed for use with both pulsed and cw beams

  4. Minimisation of the wire position uncertainties of the new CERN vacuum wire scanner

    CERN Document Server

    AUTHOR|(CDS)2069346; Barjau Condomines, A

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new fast wire scanner is foreseen to measure small emittance beams throughout the LHC injector chain, which demands a wire travelling speed up to 20 ms-1 and position measurement accuracy of the order of a few microns. The vibrations of the mechanical parts of the system, and particularly the vibrations of the thin carbon wire, were identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations is a high priority for the design and operation of the new device. This document presents the work performed to understand the main causes of the wire vibrations observed in one of the existing wire scanner and the new proposed design.

  5. Fast and High Accuracy Wire Scanner

    CERN Document Server

    Koujili, M; Koopman, J; Ramos, D; Sapinski, M; De Freitas, J; Ait Amira, Y; Djerdir, A

    2009-01-01

    Scanning of a high intensity particle beam imposes challenging requirements on a Wire Scanner system. It is expected to reach a scanning speed of 20 m.s-1 with a position accuracy of the order of 1 μm. In addition a timing accuracy better than 1 millisecond is needed. The adopted solution consists of a fork holding a wire rotating by a maximum of 200°. Fork, rotor and angular position sensor are mounted on the same axis and located in a chamber connected to the beam vacuum. The requirements imply the design of a system with extremely low vibration, vacuum compatibility, radiation and temperature tolerance. The adopted solution consists of a rotary brushless synchronous motor with the permanent magnet rotor installed inside of the vacuum chamber and the stator installed outside. The accurate position sensor will be mounted on the rotary shaft inside of the vacuum chamber, has to resist a bake-out temperature of 200°C and ionizing radiation up to a dozen of kGy/year. A digital feedback controller allows maxi...

  6. A real-time FPGA based monitoring and fault detection processing system for the Beam Wire Scanner instruments at CERN

    CERN Document Server

    AUTHOR|(CDS)2070252; Tognolini, Maurizio; Zamantzas, Christos

    The CERN Beam Instrumentation group (BE-BI) is designing a new generation of an instrument called Beam Wire Scanner (BWS). This system uses an actuator to move a very thin wire through a particle beams, back and forth with a movement stroke of pi [rad]. To achieve very fast speed when touching the particle beam with such a small stroke, large torque is applied while the expected smoothness of the displacement is crucial. This system relies on a resolver to determine the angular position and power correctly its Permanent Magnet Synchronous Motor (PMSM). In 2016, a failure of the position acquisition chain has highlighted the severe consequences of such problem, which resulted by 24 hours downtime of the Super Proton Synchrotron (SPS) accelerator with significant financial consequences. This work mitigates this single failure point by taking advantage of the existing redundancy in the sensors embedded on the system. The resolver is compared to two Incremental Optical Position Sensor (IOPS) developed in-house ...

  7. The mechatronic design of a fast wire scanner in IHEP U-70 accelerator

    International Nuclear Information System (INIS)

    Baranov, V.T.; Makhov, S.S.; Savin, D.A.; Terekhov, V.I.

    2016-01-01

    This paper presents the mechatronic design of a fast wire scanner based on a servomotor. The design of the wire scanner is motivated by the need to measure the transverse profile of the high power proton and carbon beams at the IHEP U-70 accelerator. This paper formulates the requirements to the fast wire scanner system for the high intensity proton beam at the U-70 accelerator. The results on the design of electro-mechanical device for the wire scanner with a wire traveling speed 10–20 m/s are presented. The solution consists in a brushless servomotor and standard motor control electronics. High radiation levels in the accelerator enclosure dictate the use of a resolver as the position feedback element.

  8. The mechatronic design of a fast wire scanner in IHEP U-70 accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Baranov, V.T. [Institute for High Energy Physics in National Research Centre “Kurchatov Institute”, Protvino 142281 (Russian Federation); Makhov, S.S. [Microprivod Ltd., Moscow 111123 (Russian Federation); Savin, D.A.; Terekhov, V.I. [Institute for High Energy Physics in National Research Centre “Kurchatov Institute”, Protvino 142281 (Russian Federation)

    2016-10-11

    This paper presents the mechatronic design of a fast wire scanner based on a servomotor. The design of the wire scanner is motivated by the need to measure the transverse profile of the high power proton and carbon beams at the IHEP U-70 accelerator. This paper formulates the requirements to the fast wire scanner system for the high intensity proton beam at the U-70 accelerator. The results on the design of electro-mechanical device for the wire scanner with a wire traveling speed 10–20 m/s are presented. The solution consists in a brushless servomotor and standard motor control electronics. High radiation levels in the accelerator enclosure dictate the use of a resolver as the position feedback element.

  9. Wire scanner data analysis for the SSC Linac emittance measurement

    International Nuclear Information System (INIS)

    Yao, C.Y.; Hurd, J.W.; Sage, J.

    1993-07-01

    The wire scanners are designed in the SSC Linac for measurement of beam emittance at various locations. In order to obtain beam parameters from the scan signal, a data analysis program was developed that considers the problems of noise reduction, machine modeling, parameter fitting, and correction. This program is intended as a tool for Linac commissioning and also as part of the Linac control program. Some of the results from commissioning runs are presented

  10. Mechanical optimisation of a high-precision fast wire scanner at CERN

    CERN Document Server

    Samuelsson, Sebastian; Veness, Raymond

    Wire scanners are instruments used to measure the transverse beam prole in particle accelerators by passing a thin wire through the particle beam. To avoid the issues of vacuum leakage through the bellows and wire failure related to current designs of wire scanners, a new concept for a wire scanner has been developed at CERN. This design has all moving parts inside the beam vacuum and has a nominal wire scanning speed of 20 m/s. The demands on the design associated with this together with the high precision requirements create a need for\

  11. Vacuum Actuator and Controller Design for a Fast Wire Scanner

    CERN Document Server

    Dehning, B; Herranz Alvarez, J; Koujili, M; Sirvent Blasco, J L

    2012-01-01

    To cope with increasing requirements in terms of accuracy and beam intensity limits a beam wire scanner (BWS) design is under development for the CERN accelerators complex. The main parameters have been determined; the wire speed should be 20 m·s -1 when interacting with the beam and a beam width determination accuracy of 2µm under the harsh radioactive environment should be reached. To meet this goal, the proposed solution locates all moveable parts of the actuator and the angular sensors in the beam vacuum pipe in order to reduce the friction and to allow a direct position measurement. One absolute positioning sensor will be used for the brushless motor feedback and one custom, high precision incremental design will target the beam size determination. The laboratory tests set up for the actuator and the incremental sensor will be presented along with the motor control feedback loops developed with the DSpace environment using Simulink and MatLab tools. Finally, the development of the digital...

  12. Feasibility studies on the direct wire readout on wire scanners in electron accelerators; Durchfuehrbarkeitsstudien zur direkten Drahtauslese an Wirescannern in Elektronen-Beschleunigern

    Energy Technology Data Exchange (ETDEWEB)

    Markert, Michael

    2010-10-15

    This bachelor thesis deals essentially with the signal processing of a so-called wire scanner, a special monitor, which comes to application in the beam diagnostics of particle accelerators. In this direct wire readout the voltage signal, which is induced by the particle beam in the measurement wire of the wire scanner, shall be directly read out. The aim of this thesis is to show fundamental considerations and perform studies, which study, whether and how in the future by means of a suited data transmission as well as readout electronics conclusion on the most important parameters of the beam, like position and profile, are possible. The measurement system presented here is divided in three main components: Signal measurement, signal preparation, and signal stretching. A suited test facility was developed and is presented in detail, in which then all components, like for instance the transmission cables, the wire-scanner fork, and the developed measurement circuit, are studied, which are of importance for a faultless signal transmission and presentation. Extensive measurements on the single components, as well as calculations for the signal transmission on and in the wire scanner were performed, whereby a good agreement could be found. Thereafter a comparison and a selection of the component used in this project were made. Furthermore improvement proposals, new constructions, and outlooks are presented, which could be of importance in further works.

  13. First Experimental Results And Improvements On Profile Measurements With The Vibrating Wire Scanner

    CERN Document Server

    Arutunian, S G; Dobrovolski, N M; Mailian, M R; Soghoyan, H E; Vasiniuk, I E

    2003-01-01

    The paper presents the first experimental results of transverse profile scans using a wire scanner based on a vibrating wire (vibrating wire scanner - VWS). The measurements were performed at the injector electron beam (6 nA) of the Yerevan synchrotron. The beam profile information is obtained by measuring the wire natural oscillations that depend on the wire temperature. This first experiments on weak electron beam proved this new method as a very sensitive tool, even suitable for tail measurements. Additional, improvements were tested to overcome some problems connected with signal conditioning and signal transfer in the presence of electromagnetic noise. As a result the noises were neatly separated and reduced. A mathematical method for rejection of distorted data was developed. Experiments with the scanner at the PETRA accelerator at DESY are planned for measurements of beam tails.

  14. An X-ray scanner for wire chambers

    Science.gov (United States)

    Akesson, T.; Arik, E.; Assamagan, K.; Baker, K.; Benjamin, D.; Bertelsen, H.; Bytchkov, V.; Callahan, J.; Capeans-Garrido, M.; Catinaccio, A.; Cetin, A.; Cwetanski, P.; Danielsson, H.; Dittus, F.; Dolgoshein, B.; Dressnandt, N.; Ebenstein, W. L.; Eerola, P.; Farthouat, P.; Froidevaux, D.; Grichkevitch, Y.; Hajduk, Z.; Hansen, J. R.; Keener, P. K.; Kekelidze, G.; Konovalov, S.; Kowalski, T.; Kramarenko, V. A.; Kruger, K.; Lundberg, B.; Luehring, F.; Manara, A.; McFarlane, K.; Mitsou, V. A.; Morozov, S.; Muraviev, S.; Nadtochy, A.; Newcomer, F. M.; Olszowska, J.; Ogren, H.; Oh, S. H.; Peshekhonov, V.; Price, M.; Rembser, C.; Romaniouk, A.; Rust, D. R.; Schegelsky, V.; Sapinski, M.; Shmeleva, A.; Smirnov, S.; Smirnova, L. N.; Sosnovtsev, V.; Soutchkov, S.; Spiridenkov, E.; Tikhomirov, V.; VanBerg, R.; Vassilakopoulos, V.; Wang, C.; Williams, H. H.

    2003-07-01

    The techniques to measure the position of sense wires and field wires, the gas gain and the gas flow rate inside wire chambers using a collimated and filtered X-ray beam are reported. Specific examples are given using barrel modules of the Transition Radiation Tracker of the ATLAS experiment.

  15. Performance assesment of pre-series beam wire scanner prototypes for the LHC injectors upgrade

    CERN Document Server

    AUTHOR|(CDS)2243534

    The BEAM department (BE), is in charge of the development and operation of the accelerator components. Inside this department, the Beam Instrumentation group (BE-BI) works on the instruments that allows the operators and scientists to observe the accelerated beam and its characteristics. Finally, the Profile Measurement section (BE-BI-PM) deals with all the instruments capable of measuring the particles transverse distribution (often called transverse beam profile). Among the different systems developed and maintained by the section, the Beam Wire Scanners (BWS) are particularly relevant, because ensures the accurate beam profile measurements in all the circular accelerators and serves as calibration for other instruments. A total of 31 BWS are installed in the PS, PSB, SPS and LHC (see Fig. 1 to recognize the different accelerators). All of these instruments present a different design, depending on their location, and are not satisfying the HL-LHC needs. In order to harmonize the CERN’s BWS with a single d...

  16. A fast wire scanner, used to measure the transverse density distribution of beams circulating in an accelerator or storage ring.

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    Fast wire scanners are used to measure the transverse density distribution of beams circulating in an accelerator or storage ring. In order to minimize blow-up of the beam through multiple Coulomb scattering, the wires are very thin (in the version shown here it is actually a twisted strand of carbon fibres with a total diameter of about 25 microns) and are swept through the beam at high speed (a linear motor, not mounted here, accelerates the wires to up to 20 m/s). One measures either the secondary emission current from the wire, or the signal from a scintillator/photomultiplier combination downstream from the wire scanner receiving the shower from nuclear reactions of beam particles with the wire nuclei. There are four such fast wire scanners in the 26 GeV PS and eight in the 1.4 GeV Booster.

  17. Design of a high-precision fast wire scanner for the SPS at CERN

    CERN Document Server

    Veness, R; Dehning, B; Emery, J; Herranz Alvarez, J; Koujili, M; Samuelsson, S; Sirvent, J-L

    2012-01-01

    Studies are going on of a new wire scanner concept. All moving parts are inside the beam vacuum and it is specified for use in all the machines across the CERN accelerator complex. Key components have been developed and tested. Work is now focussing on the installation of a prototype for test in the Super Proton Synchrotron (SPS) accelerator. This article presents the specification of the device and constraints on the design for integration in the different accelerators at CERN. The design issues of the mechanical components are discussed and optimisation work shown. Finally, the prototype design, integrating the several components into the vacuum tank is presented.

  18. Manually operated small envelope scanner system

    Energy Technology Data Exchange (ETDEWEB)

    Sword, Charles Keith

    2017-04-18

    A scanner system and method for acquisition of position-based ultrasonic inspection data are described. The scanner system includes an inspection probe and a first non-contact linear encoder having a first sensor and a first scale to track inspection probe position. The first sensor is positioned to maintain a continuous non-contact interface between the first sensor and the first scale and to maintain a continuous alignment of the first sensor with the inspection probe. The scanner system may be used to acquire two-dimensional inspection probe position data by including a second non-contact linear encoder having a second sensor and a second scale, the second sensor positioned to maintain a continuous non-contact interface between the second sensor and the second scale and to maintain a continuous alignment of the second sensor with the first sensor.

  19. Electrocardiogram Scanner-System Requirements

    Science.gov (United States)

    1973-03-01

    An experimental and analytical study has been conducted to establish the feasibility for scanning and digitizing electrocardiogram records. The technical requirements and relative costs for two systems are discussed herein. One is designed to automat...

  20. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems. Electrical wiring shall be installed and maintained to conform to SAE J1292—Automobile, Truck, Truck-Tractor...

  1. Design and construction of a new actuator for the LHC wire scanner

    CERN Document Server

    Koujili, Mohamed

    The LHC collides two protons beams with an energy of 7 TeV each resultingin a aimed total particle rate of about 109 Hz. The particle rateis determined by the production cross section, a natural constant and theluminosity accelerator dependent parameter describing the particle beams.The luminosity depends on the number of particles in each beam linearlyand on the transverse dimensions of the particle beam inversely. It increaseswith the particle beam density and therefore the probability of interactions.To optimize the transverse beams sizes, pro_le monitors are used to measureparameter depending changes. Within the LHC, three di_erent typesof pro_le monitors are installed: Wire scanner (WS), Synchrotron lightmonitor and Rest Gas Pro_le Monitor. The WS monitor is considered tobe the most accurate of these monitors and serves as a calibration devicefor the two others. The WS is an electro-mechanical device which measuresthe transverse beam density pro_le in an intermittent way. As the wirepasses through the be...

  2. MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Reinikainen, Heli; Blanco Sequeiros, Andreas M.; Ojala, Risto; Paeaekkoe, Eija; Tervonen, Osmo; Vaara, Teuvo

    2007-01-01

    The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and breast hook wire marking in a low-field (0.23 T) MRI system with optical instrument tracking. MR-guided core biopsy and/or hook wire marking was performed on 13 lesions observable at MR imaging only. Seven breast LCNBs and 10 hook wire markings were performed under MR guidance on 11 patients. The diagnosis was confirmed by excision biopsy or mastectomy in 12 lesions and with histopathological and cytological diagnosis and 12-month clinical follow-up in one lesion. All lesions seen in the high-field scanner were also successfully identified and targeted in the low-field scanner. The following procedures were typically technically successful. There were difficulties due to unsatisfactory functioning of some core biopsy guns. Detailed description of low-field MR guidance and optical tracking in breast biopsies is provided. The procedure seems accurate and safe and provides means to obtain a histological diagnosis of a breast lesion only seen with MRI. The low-field biopsy system is comparable to the high-field MRI system. MR-compatible biopsy guns need to be improved. (orig.)

  3. Pre-wired systems prove their worth.

    Science.gov (United States)

    2012-03-01

    The 'new generation' of modular wiring systems from Apex Wiring Solutions have been specified for two of the world's foremost teaching hospitals - the Royal London and St Bartholomew's Hospital, as part of a pounds sterling 1 billion redevelopment project, to cut electrical installation times, reduce on-site waste, and provide a pre-wired, factory-tested, power and lighting system. HEJ reports.

  4. A Vibrating Wire System For Quadrupole Fiducialization

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Zachary

    2010-12-13

    A vibrating wire system is being developed to fiducialize the quadrupoles between undulator segments in the LCLS. This note provides a detailed analysis of the system. The LCLS will have quadrupoles between the undulator segments to keep the electron beam focused. If the quadrupoles are not centered on the beam axis, the beam will receive transverse kicks, causing it to deviate from the undulator axis. Beam based alignment will be used to move the quadrupoles onto a straight line, but an initial, conventional alignment must place the quadrupole centers on a straight line to 100 {micro}m. In the fiducialization step of the initial alignment, the position of the center of the quadrupole is measured relative to tooling balls on the outside of the quadrupole. The alignment crews then use the tooling balls to place the magnet in the tunnel. The required error on the location of the quadrupole center relative to the tooling balls must be less than 25 {micro}m. In this note, we analyze a system under construction for the quadrupole fiducialization. The system uses the vibrating wire technique to position a wire onto the quadrupole magnetic axis. The wire position is then related to tooling balls using wire position detectors. The tooling balls on the wire position detectors are finally related to tooling balls on the quadrupole to perform the fiducialization. The total 25 {micro}m fiducialization error must be divided between these three steps. The wire must be positioned onto the quadrupole magnetic axis to within 10 {micro}m, the wire position must be measured relative to tooling balls on the wire position detectors to within 15 {micro}m, and tooling balls on the wire position detectors must be related to tooling balls on the quadrupole to within 10 {micro}m. The techniques used in these three steps will be discussed. The note begins by discussing various quadrupole fiducialization techniques used in the past and discusses why the vibrating wire technique is our method

  5. Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner

    CERN Document Server

    De Freitas, J; Emery, J; Herranz Alvarez, J F; Koujili, M; Ramos, D; Sapinski, M; Ait-Amira, Y; Djerdir, A

    2011-01-01

    This paper pre­sents the de­sign of the ac­tu­a­tor for the fast and high ac­cu­ra­cy Wire Scan­ner sys­tem. The ac­tu­a­tor con­sists of a ro­tary brushless syn­chronous motor with the per­ma­nent mag­net rotor in­stalled in­side the vac­u­um cham­ber and the sta­tor in­stalled out­side. The fork, per­ma­nent mag­net rotor and two an­gu­lar po­si­tion sen­sors are mount­ed on the same axis and lo­cat­ed in­side the beam vac­u­um cham­ber. The system has to re­sist a bake-out tem­per­a­ture of 200 C and ion­iz­ing radi­a­tion up to tenths of kGy/year. Max­i­mum wire trav­el­ling speed of 20 m/s and a po­si­tion mea­sure­ment ac­cu­ra­cy of 4 um is re­quired. Therefore, the sys­tem must avoid gen­er­at­ing vi­bra­tion and electromagnet­ic in­ter­fer­ence. A dig­i­tal feed­back con­troller will allow max­i­mum flex­i­bil­i­ty for the loop pa­ram­e­ters and feeds the 3-phase lin­ear power driv­er. The per­for­mance of the pr...

  6. Wire pad chamber for LHCb muon system

    CERN Document Server

    Botchine, B; Lazarev, V A; Sagidova, N; Vorobev, A P; Vorobyov, A; Vorobyov, Alexei

    2000-01-01

    2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.

  7. Integrated Electrical Wire Insulation Repair System

    Science.gov (United States)

    Williams, Martha; Jolley, Scott; Gibson, Tracy; Parks, Steven

    2013-01-01

    An integrated system tool will allow a technician to easily and quickly repair damaged high-performance electrical wire insulation in the field. Low-melt polyimides have been developed that can be processed into thin films that work well in the repair of damaged polyimide or fluoropolymer insulated electrical wiring. Such thin films can be used in wire insulation repairs by affixing a film of this low-melt polyimide to the damaged wire, and heating the film to effect melting, flow, and cure of the film. The resulting repair is robust, lightweight, and small in volume. The heating of this repair film is accomplished with the use of a common electrical soldering tool that has been modified with a special head or tip that can accommodate the size of wire being repaired. This repair method can furthermore be simplified for the repair technician by providing replaceable or disposable soldering tool heads that have repair film already "loaded" and ready for use. The soldering tool heating device can also be equipped with a battery power supply that will allow its use in areas where plug-in current is not available

  8. Benchmarking Advanced Control Algorithms for a Laser Scanner System

    DEFF Research Database (Denmark)

    Stoustrup, Jakob; Ordys, A.W.; Smillie, I.

    1996-01-01

    The paper describes tests performed on the laser scanner system toassess feasibility of modern control techniques in achieving a requiredperformance in the trajectory following problem. The two methods tested areQTR H-infinity and Predictive Control. The results are ilustated ona simulation example....

  9. Structured Wiring Systems: Bringing Sanity to Network Cabling!

    Science.gov (United States)

    Learn, Larry L., Ed.

    1995-01-01

    While most organizations, including libraries, can benefit from a structured wiring system, few likely have the expertise and resources to place, specify, and install network cabling by themselves. This article reviews common wiring plans, addresses basic concepts of structured wiring systems, and discusses the importance and benefits of such a…

  10. A laser-wire system for the International Linear Collider

    Indian Academy of Sciences (India)

    Laser-wire; accelerator test facility; laser; optical system; Compton; beam emittance; MOPA; fiber laser. Abstract. A new laser-wire has been installed in the extraction line of the ATF at KEK. It aims at demonstrating that laser-wires can be used to measure micrometre scale beam size. In parallel, studies have been made to ...

  11. A laser-wire system for the International Linear Collider

    Indian Academy of Sciences (India)

    ... line of the ATF at KEK. It aims at demonstrating that laser-wires can be used to measure micrometre scale beam size. In parallel, studies have been made to specify a laser suitable for the ILC laser-wires. Keywords. Laser-wire; accelerator test facility; laser; optical system; Compton; beam emittance; MOPA; fiber laser.

  12. In-Situ Wire Damage Detection System

    Science.gov (United States)

    Williams, Martha K. (Inventor); Roberson, Luke B. (Inventor); Tate, Lanetra C. (Inventor); Smith, Trent M. (Inventor); Gibson, Tracy L. (Inventor); Jolley, Scott T. (Inventor); Medelius, Pedro J. (Inventor)

    2014-01-01

    An in-situ system for detecting damage in an electrically conductive wire. The system includes a substrate at least partially covered by a layer of electrically conductive material forming a continuous or non-continuous electrically conductive layer connected to an electrical signal generator adapted to delivering electrical signals to the electrically conductive layer. Data is received and processed to identify damage to the substrate or electrically conductive layer. The electrically conductive material may include metalized carbon fibers, a thin metal coating, a conductive polymer, carbon nanotubes, metal nanoparticles or a combination thereof.

  13. Modern trends of aircraft fly-by-wire systems

    Directory of Open Access Journals (Sweden)

    С. С. Юцкевич

    2013-07-01

    Full Text Available Specifics of civil aviation modern transport aircraft fly-by-wire control systems are described. A comparison of the systems-level hardware and software, expressed through modes of guidance, provision of aircraft Airbus A-320, Boeing B-777, Tupolev Tu-214, Sukhoi Superjet SSJ-100 are carried out. The possibility of transition from mechanical control wiring to control through fly-by-wire system in the backup channel is shown.

  14. Imaging system models for small-bore DOI-PET scanners

    International Nuclear Information System (INIS)

    Takahashi, Hisashi; Kobayashi, Tetsuya; Yamaya, Taiga; Murayama, Hideo; Kitamura, Keishi; Hasegawa, Tomoyuki; Suga, Mikio

    2006-01-01

    Depth-of-interaction (DOI) information, which improves resolution uniformity in the field of view (FOV), is expected to lead to high-sensitivity PET scanners with small-bore detector rings. We are developing small-bore PET scanners with DOI detectors arranged in hexagonal or overlapped tetragonal patterns for small animal imaging or mammography. It is necessary to optimize the imaging system model because these scanners exhibit irregular detector sampling. In this work, we compared two imaging system models: (a) a parallel sub-LOR model in which the detector response functions (DRFs) are assumed to be uniform along the line of responses (LORs) and (b) a sub-crystal model in which each crystal is divided into a set of smaller volumes. These two models were applied to the overlapped tetragonal scanner (FOV 38.1 mm in diameter) and the hexagonal scanner (FOV 85.2 mm in diameter) simulated by GATE. We showed that the resolution non-uniformity of system model (b) was improved by 40% compared with that of system model (a) in the overlapped tetragonal scanner and that the resolution non-uniformity of system model (a) was improved by 18% compared with that of system model (b) in the hexagonal scanner. These results indicate that system model (b) should be applied to the overlapped tetragonal scanner and system model (a) should be applied to the hexagonal scanner. (author)

  15. Design of an optical fibre based angular position sensor for wire scanners complying with ultra-high vacuum, high temperature and radiation conditions of the CERN´s accelerators

    CERN Document Server

    Sirvent Blasco, Jose Luis; Azorin Poveda, Jose Maria

    The main objective of this thesis is to design and implement the relative optical position sensor based on optical fibre, related to the new design of wire scanner, also taking into account the general specifications of the whole design of the Vacuum Wire Scanner (VWS from here in advanced). According to the limitations of the environment this sensor must work under very hard conditions and provide as much accuracy as possible, this means that all the components must be carefully selected and also rated to high temperature, ultra high vacuum and radiation environment to provide the longest life time as possible.

  16. Wire compensation: Performance, SPS MDs, pulsed system

    CERN Document Server

    Dorda, U

    2008-01-01

    A wire compensation (BBLR) scheme has been proposed in order to improve the long range beam-beam performance of the nominal LHC and its phase 1 and phase 2 upgrades[1]. In this paper we present experimental experience of the CERN SPS wires (BBLR) and report on progress with the RF BBLR.

  17. System and method for evaluating a wire conductor

    Science.gov (United States)

    Panozzo, Edward; Parish, Harold

    2013-10-22

    A method of evaluating an electrically conductive wire segment having an insulated intermediate portion and non-insulated ends includes passing the insulated portion of the wire segment through an electrically conductive brush. According to the method, an electrical potential is established on the brush by a power source. The method also includes determining a value of electrical current that is conducted through the wire segment by the brush when the potential is established on the brush. The method additionally includes comparing the value of electrical current conducted through the wire segment with a predetermined current value to thereby evaluate the wire segment. A system for evaluating an electrically conductive wire segment is also disclosed.

  18. Crewmember repairing the Regenerative Carbon Dioxide Removal System wiring.

    Science.gov (United States)

    1992-01-01

    Mission Pilot Ken Bowersox, busy at work on the wiring harness for the Regenerative Carbon Dioxide Removal System located under the mid deck floor. Photo shows Bowersox splicing wires together to 'fool' a faulty sensor that caused the 'air conditioner' to shut down.

  19. Wiring System Diagnostic Techniques for Legacy Aircraft

    Science.gov (United States)

    2003-02-01

    Reunions des specialistes des techniques de estion du cycle de vie pour vehicules aeriens vieillissants ] To order the complete compilation report, use...Ageing Mechanisms and Control. Specialists’ Meeting on Life Management Techniques for Ageing Air Vehicles [Les mecanismes vieillissants et le controle...be identified. Additionally, wiring failures tend to be intermittent in nature and can take considerable time to isolate. Wire modifications and

  20. The Wire Flyer Towed Profiling System

    Science.gov (United States)

    Roman, C.; Ullman, D. S.; Hebert, D.

    2016-02-01

    The Wire Flyer is an autonomous profiling vehicle that slides up and down a standard towed cable in a controlled manner using the lift created by wing foils. The vehicle is able to create high resolution water-column sections within a specified depth band in an automated manner. The Wire Flyer is different than standard undulating tow bodies in that it decouples the vehicle's motion from the tow cable dynamics. Due to this separation the vehicle is able to profile with nearly 1:1 horizontal to vertical motion. A heavy depressor weight is fixed to the end of the cable and the cable shape remains relatively static during operation. The vehicle uses a closed loop wing angle controller to achieve desired vertical velocities between 0 and 2.5 m/s for ship speeds between 1.5 and 2.5 m/s. During typical operations, updated commands and condensed data samples can be sent to and from the vehicle via an acoustic modem to adjust the profiling pattern to ensure the desired coverage. The current 1000 meter rated vehicle is equipped with a SBE 49 FastCAT CTD, and can carry additional sensors for oxygen, Chlorophyll fluorescence and acoustic echosounding. Results showing the vehicle performance as well as the quality of the processed CTD data will be presented from three test cruises to the New England Shelf Break Front. Many shallow and deep sections were obtained with horizontal resolution that is not otherwise achievable with undulating tow bodies, underway CTDs, standard CTD tow-yos, gliders or free swimming AUVs. A typical survey at ship speeds of 3-4 knots can profile over a depth band between 200 and 600 meters depth with a repeat cycle length of less than 1 km. The vehicle concept is depth independent and could work with a full ocean depth design. Application areas for the system include sub-meso scale observations of fronts, vent and seep plumes, oxygen minimum layers, mixing and mid-water bioacoustics.

  1. Beam Position and Phase Monitor - Wire Mapping System

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Heath A [Los Alamos National Laboratory; Shurter, Robert B. [Los Alamos National Laboratory; Gilpatrick, John D. [Los Alamos National Laboratory; Kutac, Vincent G. [Los Alamos National Laboratory; Martinez, Derwin [Los Alamos National Laboratory

    2012-04-10

    The Los Alamos Neutron Science Center (LANSCE) deploys many cylindrical beam position and phase monitors (BPPM) throughout the linac to measure the beam central position, phase and bunched-beam current. Each monitor is calibrated and qualified prior to installation to insure it meets LANSCE requirements. The BPPM wire mapping system is used to map the BPPM electrode offset, sensitivity and higher order coefficients. This system uses a three-axis motion table to position the wire antenna structure within the cavity, simulating the beam excitation of a BPPM at a fundamental frequency of 201.25 MHz. RF signal strength is measured and recorded for the four electrodes as the antenna position is updated. An effort is underway to extend the systems service to the LANSCE facility by replacing obsolete electronic hardware and taking advantage of software enhancements. This paper describes the upgraded wire positioning system's new hardware and software capabilities including its revised antenna structure, motion control interface, RF measurement equipment and Labview software upgrades. The main purpose of the wire mapping system at LANSCE is to characterize the amplitude response versus beam central position of BPPMs before they are installed in the beam line. The wire mapping system is able to simulate a beam using a thin wire and measure the signal response as the wire position is varied within the BPPM aperture.

  2. Wire system ageing assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. (Institute for Energy Technology (IFE) (Norway))

    2009-07-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains the results of experiments performed in collaboration with Tecnatom SA, Spain, to compare several cable condition monitoring techniques including LIRA (LIne Resonance Analysis) (au)

  3. Wire system ageing assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Fantoni, P.F.

    2009-07-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains the results of experiments performed in collaboration with Tecnatom SA, Spain, to compare several cable condition monitoring techniques including LIRA (LIne Resonance Analysis) (au)

  4. Validity and Repeatability of the Sizestream 3D Scanner and Poikos Modeling System

    NARCIS (Netherlands)

    Vonk, T.E.; Daanen, H.A.M.

    2015-01-01

    Three-dimensional (3D) body scanning becomes increasingly important in the medical, ergonomical and apparel industry. The SizeStream 3D body scanner is a 3D body scanner in the shape of a fitting room that can generate a 3D copy of the human body in a few seconds. The Poikos modeling system

  5. Strain sensing systems tailored for tensile measurement of fragile wires

    Science.gov (United States)

    Nyilas, Arman

    2005-12-01

    Fundamental stress versus strain measurements were completed on superconducting Nb3Sn wires within the framework of IEC/TC90 and VAMAS/TWA16. A key task was the assessment of sensing systems regarding resolution, accuracy, and precision when measuring Young's modulus. Prior to actual Nb3Sn wire measurements metallic wires, consisting of copper and stainless steel having diameters similar to the Nb3Sn wire, were extensively investigated with respect to their elastic line properties using different types of extensometers. After these calibration tests Nb3Sn wire measurements of different companies resulted in several important facts with respect to total size and weight of the used extensometers. The size could be correlated to the initial stage of stress versus strain behaviour. In fact, the effect of wire curls resulting from the production line had a profound effect on Young's modulus measurements. Within this context, the possibility of determining Young's modulus from unloading compliance lines in the plastic regime of the stress-strain curve was considered. The data obtained using this test methodology were discussed under consideration of the composite nature of Nb3Sn wire. In addition, a non-contacting sensing system based on a double-beam laser extensometer was used to investigate the potential of this new sensing system.

  6. Strain sensing systems tailored for tensile measurement of fragile wires

    International Nuclear Information System (INIS)

    Nyilas, Arman

    2005-01-01

    Fundamental stress versus strain measurements were completed on superconducting Nb 3 Sn wires within the framework of IEC/TC90 and VAMAS/TWA16. A key task was the assessment of sensing systems regarding resolution, accuracy, and precision when measuring Young's modulus. Prior to actual Nb 3 Sn wire measurements metallic wires, consisting of copper and stainless steel having diameters similar to the Nb 3 Sn wire, were extensively investigated with respect to their elastic line properties using different types of extensometers. After these calibration tests Nb 3 Sn wire measurements of different companies resulted in several important facts with respect to total size and weight of the used extensometers. The size could be correlated to the initial stage of stress versus strain behaviour. In fact, the effect of wire curls resulting from the production line had a profound effect on Young's modulus measurements. Within this context, the possibility of determining Young's modulus from unloading compliance lines in the plastic regime of the stress-strain curve was considered. The data obtained using this test methodology were discussed under consideration of the composite nature of Nb 3 Sn wire. In addition, a non-contacting sensing system based on a double-beam laser extensometer was used to investigate the potential of this new sensing system

  7. Wire system aging assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. [Institutt for energiteknikk, IFE (Norway)

    2007-04-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains some test results of a method for wire system condition monitoring, developed at the Halden Reactor Project, called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. (au)

  8. Global Positioning Radiometric Scanner System. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    2001-01-01

    The US DOE continually seeks safer and more cost-effective technologies for use in decontamination and decommissioning (D and D) of nuclear facilities. To this end, the Deactivation and Decommissioning Focus Area (DDFA) of the DOE OST sponsors the Large Scale Demonstration and Deployment Projects (LSDDP). At these LSDDPs, developers and vendors of improved or innovative technologies showcase products that are potentially beneficial to the DOE projects and to others in the D and D community. Benefits sought include decreased health and safety risks to personnel and the environment, increased productivity, and decreased costs of operation. The Idaho National Engineering and Environmental Laboratory (INEEL) LSDDP generated a list of statements defining specific needs or problems where improved technology could be incorporated into ongoing D and D tasks. One of the stated needs was for developing technologies that would reduce costs and shorten DDOE/EM--0552DOE/EM--0552 and D schedules by providing radiological characterizations to meet the free-release criteria. The Global Positioning Radiometric Scanner (GPRS system shown in Figure 1) utilizes a detection system; a portable computer, a differential global positioning system (d-gps), and a four wheel drive vehicle. Once the survey data has been collected, a software program called GeoSofttrademark generates a graphical representation of the radiological contamination extent. Baseline technology involves gridding the area and hand surveying each grid. This demonstration investigated the associated costs and the required time to evaluate the radiological characterization data from the GPRS with respect to the baseline technology. The GPRS system performs in-situ, real-time analyses to identify the extent of radiological contamination. Benefits expected from using the new innovative technology (GPRS) include: Reduced labor hours associated with performing the survey; Increased number of survey data points; Reduced

  9. Mobile network architecture of the long-range WindScanner system

    DEFF Research Database (Denmark)

    Vasiljevic, Nikola; Lea, Guillaume; Hansen, Per

    the requirements of running the long-range WindScanner system using a mobile network such as 3G. This architecture allows us to have the WindScanners and the master computer in different geographical locations, and in general facilitates deployments of the long-range WindScanner system.......In this report we have presented the network architecture of the long-range WindScanner system that allows utilization of mobile network connections without the use of static public IP addresses. The architecture mitigates the issues of additional fees and contractual obligations that are linked...... to the acquisition of the mobile network connections with static public IP addresses. The architecture consists of a hardware VPN solution based on the network appliances Z1 and MX60 from Cisco Meraki with additional 3G or 4G dongles. With the presented network architecture and appropriate configuration, we fulfill...

  10. Wiring visual systems: common and divergent mechanisms and principles.

    Science.gov (United States)

    Kolodkin, Alex L; Hiesinger, P Robin

    2017-02-01

    The study of visual systems has a rich history, leading to the discovery and understanding of basic principles underlying the elaboration of neuronal connectivity. Recent work in model organisms such as fly, fish and mouse has yielded a wealth of new insights into visual system wiring. Here, we consider how axonal and dendritic patterning in columns and laminae influence synaptic partner selection in these model organisms. We highlight similarities and differences among disparate visual systems with the goal of identifying common and divergent principles for visual system wiring. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. New Structure Design and Simulation of Brake by Wire System Based on Giant-magnetostrictive Material

    Directory of Open Access Journals (Sweden)

    Changbao CHU

    2014-04-01

    Full Text Available Existing electronic mechanical brake by wire system has several disadvantages. For instance, system actuators are complex, response speed slower, larger vibration noise, etc. This paper discusses a new type brake by wire system based on giant-magnetostrictive material. The new type brake by wire system model was set up under Matlab/Simulink software environment. PID control method was used to control the brake by wire system. Simulation results shows that the new type brake by wire system achieves better braking performance compared with hydraulic braking system. This work provides a new idea for researching automobile brake by wire system.

  12. Wire system aging assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Fantoni, P.F.; Nordlund, A.

    2006-04-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report describes a method for wire system condition monitoring, developed at the Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. LIRA is composed of a signal generator, a signal analyser and a simulator that can be used to simulate several failure/degradation scenarios and assess the accuracy and sensitivity of the LIRA system. Chapter 5 of this report describes an complementary approach based on positron measurement techniques, used widely in defect physics due to the high sensitivity to micro defects, in particular open volume defects. This report describes in details these methodologies, the results of field experiments and the proposed future work. (au)

  13. Wire system aging assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. [Institutt for energiteknikk (Norway); Nordlund, A. [Chalmers Univ. of Technology (Sweden)

    2006-04-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report describes a method for wire system condition monitoring, developed at the Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. LIRA is composed of a signal generator, a signal analyser and a simulator that can be used to simulate several failure/degradation scenarios and assess the accuracy and sensitivity of the LIRA system. Chapter 5 of this report describes an complementary approach based on positron measurement techniques, used widely in defect physics due to the high sensitivity to micro defects, in particular open volume defects. This report describes in details these methodologies, the results of field experiments and the proposed future work. (au)

  14. Development of a portable computed tomographic scanner for on-line imaging of industrial piping systems

    International Nuclear Information System (INIS)

    Jaafar Abdullah; Mohd Arif Hamzah; Mohd Soyapi Mohd Yusof; Mohd Fitri Abdul Rahman; Fadil IsmaiI; Rasif Mohd Zain

    2003-01-01

    Computed tomography (CT) technology is being increasingly developed for industrial application. This paper presents the development of a portable computed tomographic scanner for on?line imaging of industrial piping systems. The theoretical approach, the system hardware, the data acquisition system and the adopted algorithm for image reconstruction are discussed. The scanner has large potential to be used to determine the extent of corrosion under insulation (CUI), to detect blockages, to measure the thickness of deposit/materials built-up on the walls and to improve understanding of material flow in pipelines. (Author)

  15. Upgrading PABX Infra System and Wiring for Communication System in Selected Block

    International Nuclear Information System (INIS)

    Sahirudden Mohd Nor; Khairiah Yazid; Lojius Lombigit; Zainuddin Jaafar; Abd Aziz Mhd Ramli

    2015-01-01

    Infra phone system in Nuclear Malaysia has been operating since its inception. Infra phone system is used to enable the communications process run smoothly. There are two mains phone system which are mannex analog system in the main complex and MD110 systems in Dengkil complex. This system was responsibilities and monitored by Automation and Instrumentation Center, Technical Support Division. Infra phone system and its wiring in the main complexes have not been upgraded and there are a lot of faulty wiring. This phone system requires new wiring system with the addition of new buildings in Nuclear Malaysia. The system also requires new parts to ensure smooth communication system in future. (author)

  16. MRI compatible small animal monitoring and trigger system for whole body scanners

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, Karl-Heinz; Krumbein, Ines; Reichenbach, Juergen R. [Jena University Hospital (Germany). Medical Physics Group; Pfeiffer, Norman [Jena University Hospital (Germany). Medical Physics Group; Ernst-Abbe-Fachhochschule Jena (Germany); Herrmann, Lutz [Ernst-Abbe-Fachhochschule Jena (Germany)

    2014-03-01

    Performing magnetic resonance imaging (MRI) experiments with small animals requires continuous monitoring of vital parameters, especially the respiration rate. Clinical whole-body MR scanners represent an attractive option for preclinical imaging as dedicated animal scanners are cost-intensive in both investment and maintenance, thus limiting their availability. Even though impressive image quality is achievable with clinical MR systems in combination with special coils, their built-in physiologic monitoring and triggering units are often not suited for small animal imaging. In this work, we present a simple, MRI compatible low cost solution to monitor the respiration and heart rate of small animals in a clinical whole-body MR scanner. The recording and processing of the biosignals as well as the optimisation of the respiratory trigger generation is described. Additionally rat and mouse in-vivo MRI experiments are presented to illustrate the effectiveness of the monitoring and respiratory trigger system in suppressing motion artifacts. (orig.)

  17. 75 FR 65051 - Consensus Standards, Standard Practice for Inspection of Airplane Electrical Wiring Systems

    Science.gov (United States)

    2010-10-21

    ... Practice for Inspection of Airplane Electrical Wiring Systems AGENCY: Federal Aviation Administration, DOT...'s F2696-08 Standard Practice for Inspection of Airplane Electrical Wiring Systems (Standard Practice) as an acceptable means of compliance to 14 CFR part 23 sections concerning electrical wiring systems...

  18. 14 CFR 121.1111 - Electrical wiring interconnection systems (EWIS) maintenance program.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Electrical wiring interconnection systems... Airworthiness and Safety Improvements § 121.1111 Electrical wiring interconnection systems (EWIS) maintenance... wiring interconnection systems (EWIS). (c) The proposed EWIS maintenance program changes must be based on...

  19. The simulation of a data acquisition system for a proposed high resolution PET scanner

    International Nuclear Information System (INIS)

    Rotolo, C.; Larwill, M.; Chappa, S.; Ordonez, C.

    1993-10-01

    The simulation of a specific data acquisition (DAQ) system architecture for a proposed high resolution Positron Emission Tomography (PET) scanner is discussed. Stochastic processes are used extensively to model PET scanner signal timing and probable DAQ circuit limitations. Certain architectural parameters, along with stochastic parameters, are varied to quantatively study the resulting output under various conditions. The inclusion of the DAQ in the model represents a novel method of more complete simulations of tomograph designs, and could prove to be of pivotal importance in the optimization of such designs

  20. The simulation of a data acquisition system for a proposed high resolution PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    Rotolo, C.; Larwill, M.; Chappa, S. [Fermi National Accelerator Lab., Batavia, IL (United States); Ordonez, C. [Chicago Univ., IL (United States)

    1993-10-01

    The simulation of a specific data acquisition (DAQ) system architecture for a proposed high resolution Positron Emission Tomography (PET) scanner is discussed. Stochastic processes are used extensively to model PET scanner signal timing and probable DAQ circuit limitations. Certain architectural parameters, along with stochastic parameters, are varied to quantatively study the resulting output under various conditions. The inclusion of the DAQ in the model represents a novel method of more complete simulations of tomograph designs, and could prove to be of pivotal importance in the optimization of such designs.

  1. Wire system ageing assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Ekelund, M; Gedde, U.W. (Royal Institute of Technology (KTH). Fibre and Polymer Technology, School of Chemical Science and Engineering, Stockholm (Sweden)); Fantoni, P.F. (Institute for Energy Technology (IFE), Halden (Norway))

    2011-05-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. In this report 3 techniques for cable global ageing assessment were tested and evaluated. The EAB technique is a destructive, local technique that is often used as a reference for other methods. The indenter is a local, in-situ mechanical technique that is currently quite often used in NPPs. LIRA is an electrical method, full line, in-situ. LIRA correlated quite well with EAB and both tend to flatten when the ageing time reaches 40 years. The only cable type that was difficult to assess for all the 3 methods was the medium type in air environment. These tests considered only thermal ageing, up to 50 years and should be completed by considering also gamma irradiation ageing. (Author)

  2. Wire system ageing assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Ekelund, M; Gedde, U.W.; Fantoni, P.F.

    2011-05-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. In this report 3 techniques for cable global ageing assessment were tested and evaluated. The EAB technique is a destructive, local technique that is often used as a reference for other methods. The indenter is a local, in-situ mechanical technique that is currently quite often used in NPPs. LIRA is an electrical method, full line, in-situ. LIRA correlated quite well with EAB and both tend to flatten when the ageing time reaches 40 years. The only cable type that was difficult to assess for all the 3 methods was the medium type in air environment. These tests considered only thermal ageing, up to 50 years and should be completed by considering also gamma irradiation ageing. (Author)

  3. A UGV-based laser scanner system for measuring tree geometric characteristics

    Science.gov (United States)

    Wang, Yonghui; Lan, Yubin; Zheng, Yongjun; Lee, Kevin; Cui, Suxia; Lian, Jian-ao

    2013-09-01

    This paper introduces a laser scanner based measurement system for measuring crop/tree geometric characteristics. The measurement system, which is mounted on a Unmanned Ground Vehicle (UGV), contains a SICK LMS511 PRO laser scanner, a GPS, and a computer. The LMS511 PRO scans objects within distance up to 80 meters with a scanning frequency of 25 up to 100Hz and with an angular resolution of 0.1667° up to 1°. With an Ethernet connection, this scanner can output the measured values in real time. The UGV is a WIFI based remotely controlled agricultural robotics system. During field tests, the laser scanner was mounted on the UGV vertically to scan crops or trees. The UGV moved along the row direction with certain average travel speed. The experimental results show that the UGV's travel speed significantly affects the measurement accuracy. A slower speed produces more accurate measuring results. With the developed measurement system, crop/tree canopy height, width, and volume can be accurately measured in a real-time manner. With a higher spatial resolution, the original data set may even provide useful information in predicting crop/tree growth and productivity. In summary, the UGV based measurement system developed in this research can measure the crop/tree geometric characteristics with good accuracy and will work as a step stone for our future UGV based intelligent agriculture system, which will include variable rate spray and crop/tree growth and productivity prediction through analyzing the measured results of the laser scanner system.

  4. Comparison of H-infinity control and generalized predictive control for a laser scanner system

    DEFF Research Database (Denmark)

    Ordys, A.W.; Stoustrup, Jakob; Smillie, I.

    2000-01-01

    This paper describes tests performed on a laser scanner system to assess the feasibility of H-infinity control and generalized predictive control design techniques in achieving a required performance in a trajectory folowing problem. The two methods are compared with respect to achieved scan time...

  5. 75 FR 65052 - Consensus Standards, Standard Practice for Maintenance of Airplane Electrical Wiring Systems

    Science.gov (United States)

    2010-10-21

    ... Practice for Maintenance of Airplane Electrical Wiring Systems AGENCY: Federal Aviation Administration, DOT...'s F2799-09 Standard Practice for Maintenance of Airplane Electrical Wiring Systems (Standard Practice) as an acceptable means of compliance to 14 CFR part 23 sections concerning electrical wiring...

  6. Analysis of electrical explosion of wire systems for the production of ...

    Indian Academy of Sciences (India)

    With the intention of developing better exploding wire system for the produc- ... the emphasise has been given to explain the process involved to produce nano phase material by EEW method experimentally. 2. Theory. For a wire of length 'l' and ... One exploder is a cage type open system (set-up I) where wires are mounted ...

  7. Stepped scanner radiographic imaging system using edge blending

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1984-01-01

    An imaging system is described which includes a radiographic camera, a bed for supporting a subject in view of the camera, and a display system. The camera provides X and Y coordinate signals for each radiographic event. The position of the bed relative to the camera is altered stepwise and a sequence of images is provided by the camera each image being positioned on a display system in correspondence with the location of the bed relative to the camera. The camera is electronically decoupled from the display by a gate during movement of the bed relative to the camera from one location to the next location to prevent any smearing effect within the composite image presented on the display. The edges of contiguous images making up the composite image are blended by electronically adjusting their boundary regions so as to provide overlapping or interlocking. (author)

  8. SLAC Scanner Processor applications in the data acquisition system for the upgraded Mark II detector

    International Nuclear Information System (INIS)

    Barklow, T.; Glanzman, T.; Lankford, A.J.; Riles, K.

    1985-09-01

    The SLAC Scanner Processor is a general purpose, programmable FASTBUS crate/cable master/slave module. This device plays a central role in the readout, buffering and pre-processing of data from the upgraded Mark II detector's new central drift chamber. In addition to data readout, the SSPs assist in a variety of other services, such as detector calibration, FASTBUS system management, FASTBUS system initialization and verification, and FASTBUS module testing. 9 refs., 1 fig., 2 tabs

  9. Investigation of Constant Temperature Hot-wire System Response using Laser Pulse

    Science.gov (United States)

    Jaffa, Nicholas; Morris, Scott; Cameron, Joshua

    2016-11-01

    Constant temperature hot-wire systems use a Wheatstone bridge and feedback amplifier circuit to maintain a constant average temperature across the wire yielding frequency responses of order 100 kHz. This high frequency response allows hot-wires to be used extensively for aerodynamic measurements in high speed flows and uncertainty at these high frequencies can be difficult to diagnose. The standard frequency response check for constant temperature hot-wires uses an electronic pulse across the circuit to check the electronic feedback circuit response time, but does not account for the impact of the heat transfer along the wire. In order to investigate the frequency response of the entire constant temperature hot-wire system, including the heat transfer along the wire, a novel method was developed using a pulsed PIV laser focused to illuminate only the hot-wire. The laser pulse duration was effectively an instantaneous change in wire surface temperature through radiation. A hot-wire was placed in a uniform open calibration jet for a range of flow conditions. The response of the entire hot-wire system was observed across a range of conditions including changes in flow, wire temperature, and thermal boundary conditions and compared with the electronic pulse test.

  10. Acquisition And Processing Of Range Data Using A Laser Scanner-Based 3-D Vision System

    Science.gov (United States)

    Moring, I.; Ailisto, H.; Heikkinen, T.; Kilpela, A.; Myllyla, R.; Pietikainen, M.

    1988-02-01

    In our paper we describe a 3-D vision system designed and constructed at the Technical Research Centre of Finland in co-operation with the University of Oulu. The main application fields our 3-D vision system was developed for are geometric measurements of large objects and manipulator and robot control tasks. It seems to be potential in automatic vehicle guidance applications, too. The system has now been operative for about one year and its performance has been extensively tested. Recently we have started a field test phase to evaluate its performance in real industrial tasks and environments. The system consists of three main units: the range finder, the scanner and the computer. The range finder is based on the direct measurement of the time-of-flight of a laser pulse. The time-interval between the transmitted and the received light pulses is converted into a continuous analog voltage, which is amplified, filtered and offset-corrected to produce the range information. The scanner consists of two mirrors driven by moving iron galvanometers. This system is controlled by servo amplifiers. The computer unit controls the scanner, transforms the measured coordinates into a cartesian coordinate system and serves as a user interface and postprocessing environment. Methods for segmenting the range image into a higher level description have been developed. The description consists of planar and curved surfaces and their features and relations. Parametric surface representations based on the Ferguson surface patch are studied, too.

  11. Novel calibration system with sparse wires for CMB polarization receivers

    Energy Technology Data Exchange (ETDEWEB)

    Tajima, O.; /KEK, Tsukuba /Chicago U., KICP; Nguyen, H.; /Fermilab; Bischoff, C.; /Chicago U., KICP /Harvard-Smithsonian Ctr. Astrophys.; Brizius, A.; Buder, I.; Kusaka, A. /Chicago U., KICP

    2011-07-01

    B-modes in the cosmic microwave background (CMB) polarization is a smoking gun signature of the inflationary universe. To achieve better sensitivity to this faint signal, CMB polarization experiments aim to maximize the number of detector elements, resulting in a large focal plane receiver. Detector calibration of the polarization response becomes essential. It is extremely useful to be able to calibrate 'simultaneously' all detectors on the large focal plane. We developed a novel calibration system that rotates a large 'sparse' grid of metal wires, in front of and fully covering the field of view of the focal plane receiver. Polarized radiation is created via the reflection of ambient temperature from the wire surface. Since the detector has a finite beam size, the observed signal is smeared according to the beam property. The resulting smeared polarized radiation has a reasonable intensity (a few Kelvin or less) compared to the sky temperature ({approx}10 K observing condition). The system played a successful role for receiver calibration of QUIET, a CMB polarization experiment located in the Atacama desert in Chile. The successful performance revealed that this system is applicable to other experiments based on different technologies, e.g. TES bolometers.

  12. Development of a portable and fast wire tension measurement system for MWPC construction

    Science.gov (United States)

    Pan, Jing-Hui; Ma, Chang-Li; Gong, Xue-Yu; Sun, Zhi-Jia; Wang, Yan-Feng; Yin, Chen-Yan; Gong, Lei

    2016-09-01

    In a multi-wire proportional chamber detector (MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector’s stable and accurate performance. As a result, wire tension control and measurement is essential in MWPC construction. A high pressure 3He MWPC detector is to be used as the thermal neutron detector of the multi-functional reflectometer at China Spallation Neutron Source, and in the construction of the detector, we have developed a wire tension measurement system. This system is accurate, portable and time-saving. With it, the wire tension on an anode wire plane has been tested. The measurement results show that the wire tension control techniques used in detector manufacture are reliable. Supported by National Natural Science Foundation of China (A050506), State Key Laboratory of Particle Detection and Electronics and Key Laboratory of China Academy of Engineering Physics (Y490KF40HD)

  13. Vibrating wire for beam profile scanning

    Directory of Open Access Journals (Sweden)

    S. G. Arutunian

    1999-12-01

    Full Text Available A method that measures the transverse profile (emittance of the bunch by detecting radiation arising at the scattering of the bunch on scanning wire is widely used. In this work information about bunch scattering is obtained by measuring the oscillation frequency of the tightened scanning wire. In such a way, the system of radiation (or secondary particles extraction and measurement can be removed. The entire unit consists of a compact fork with tightened wire and a scanning system. Normal oscillation frequency of a wire depends on wire tension, its geometric parameters, and, in a second approximation, its elastic characteristics. Normal oscillations are generated by interaction of an alternating current through the wire with magnetic field of a permanent magnet. In this case, it is suggested that the magnetic field of the accelerator (field of dipole magnets or quadrupole magnets be used for excitation of oscillations. The dependence of oscillation frequency on beam scattering is determined by several factors, including changes of wire tension caused by transverse force of the beam and influence of beam self-field. Preliminary calculations show that the influence of wire heating will dominate. We have studied strain gauges on the basis of vibrating wire from various materials (tungsten, beryl bronze, and niobium zirconium alloys. A scheme of normal oscillation generation by alternating current in autogeneration circuit with automatic frequency adjustment was selected. A special method of wire fixation and elimination of transverse degrees of freedom allows us to achieve relative stability better than 10^{-5} during several days at a relative resolution of 10^{-6}. Experimental results and estimates of wire heating of existing scanners show that the wire heats up to a few hundred grades, which is enough for measurements. The usage of wire of micrometer thickness diminishes the problem of wire thermalization speed during the scanning of the bunch.

  14. 47 CFR 68.213 - Installation of other than “fully protected” non-system simple customer premises wiring.

    Science.gov (United States)

    2010-10-01

    ... non-system simple customer premises wiring. 68.213 Section 68.213 Telecommunication FEDERAL... protected” non-system simple customer premises wiring. (a) Scope of this rule. Provisions of this rule apply only to “unprotected” premises wiring used with simple installations of wiring for up to four line...

  15. A combined positron emission tomography (PET)- electron paramagnetic resonance imaging (EPRI) system: initial evaluation of a prototype scanner.

    Science.gov (United States)

    Tseytlin, Mark; Stolin, Alexander V; Guggilapu, Priyaankadevi; Bobko, Andrey A; Khramtsov, Valery V; Tseytlin, Oxana; Raylman, Raymond R

    2018-04-20

    The advent of hybrid scanners, combining complementary modalities, has revolutionized imaging; enhancing clinical practice and biomedical research. In this project, we investigated the melding of two complementary, functional imaging methods: positron emission tomography (PET) and electron paramagnetic resonance imaging (EPRI). The PET radiotracers can provide important information about cellular parameters, such as glucose metabolism. While EPR probes can provide assessment of tissue microenvironment, measuring parameters such as oxygenation and pH, for example. A combined PET/EPRI scanner has the promise to provide new insights not attainable with current imagers by simultaneous acquisition of multiple components of tissue microenvironments. In this investigation, a prototype system was created by combing two existing scanners, modified for simultaneous imaging. Specifically, a silicon photomultiplier (SiPM) based PET scanner ring designed as a portable scanner was combined with an EPRI scanner designed for the imaging of small animals. The ability of the system to obtain simultaneous images was assessed with a small phantom consisting of four cylinders containing both PET and EPR tracers. The resulting images demonstrated the ability to obtain contemporaneous PET and ERP images without cross-modality interference. The next step in this project is the construction of pre-clinical PET/EPRI scanner for multi-parametric assessment of physiologically important parameters of tissue microenvironments. . © 2018 Institute of Physics and Engineering in Medicine.

  16. Research on Handling Stability of Steering-by-wire System

    Directory of Open Access Journals (Sweden)

    Yuan Ying

    2017-01-01

    Full Text Available The main function of steer-by-wire (SBW system are improving steering characteristics, security and stability of the vehicle. In this paper, the variable steering ratio of SBW system is analyzed, and the method of steering ratio based on fuzzy control and neural network are researched. In order to solve the actual working condition, the wheel angle may not reach the expected value, this paper establishes a twodegree-of-freedom (2-DOF vehicle model, and a Matlab/Simulink simulation model, in which a control strategy based on PID controller is put forward to control the front wheel steering angle. Simulation results show that proposed control strategy based on fuzzy neural network can effectively reduce lateral deviation and improve the handling stability and comfortability of the vehicle.

  17. The Smartphone Brain Scanner: A Portable Real-Time Neuroimaging System

    DEFF Research Database (Denmark)

    Stopczynski, Arkadiusz; Stahlhut, Carsten; Larsen, Jakob Eg

    2014-01-01

    Combining low-cost wireless EEG sensors with smartphones offers novel opportunities for mobile brain imaging in an everyday context. Here we present the technical details and validation of a framework for building multi-platform, portable EEG applications with real-time 3D source reconstruction....... The system – Smartphone Brain Scanner – combines an off-the-shelf neuroheadset or EEG cap with a smartphone or tablet, and as such represents the first fully portable system for real-time 3D EEG imaging. We discuss the benefits and challenges, including technical limitations as well as details of real...

  18. 14 CFR 26.11 - Electrical wiring interconnection systems (EWIS) maintenance program.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical wiring interconnection systems (EWIS) maintenance program. 26.11 Section 26.11 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... AIRPLANES Enhanced Airworthiness Program for Airplane Systems § 26.11 Electrical wiring interconnection...

  19. A study of the dose modulation systems in two multislice CT scanners

    International Nuclear Information System (INIS)

    Hernandez Giron, I.; Valverde Moran, J.; Mendez Fernandez, R.; Aramburu Nunez, D.; Nunez Villavicencio, C.; Calzado Cantera, A.

    2009-01-01

    Multislice computed tomography (TCMC) is a technique that for its gradual introduction and the spectacular increase in its indications in clinical practice represents the main contribution to the collective dose in diagnostic radiology. It is essential to optimize the protocols maintaining doses as low as possible without affecting the diagnostic quality of images. Automatic tube current modulation systems are a tool currently available in all CT scanners. They adapt the tube current to morphological characteristics of the patient and the anatomical area under study. The aim of this work has been to analyze two scanners from the same manufacturer and featuring similar geometry by assessing the relative dose differences and image quality. Modulation systems of general use can decrease the dose in a 20-60% with a reduction in the signal to noise ratio between 6% and 37%. Dedicated cardiac-CT modulation system gave rise to high relative differences (36-40%) even when varying the heart rate. Significant changes in image quality were not appreciated though the motion of the heart has not been simulated in this study. (Author) 14 refs.

  20. Genetic Control of Wiring Specificity in the Fly Olfactory System

    Science.gov (United States)

    Hong, Weizhe; Luo, Liqun

    2014-01-01

    Precise connections established between pre- and postsynaptic partners during development are essential for the proper function of the nervous system. The olfactory system detects a wide variety of odorants and processes the information in a precisely connected neural circuit. A common feature of the olfactory systems from insects to mammals is that the olfactory receptor neurons (ORNs) expressing the same odorant receptor make one-to-one connections with a single class of second-order olfactory projection neurons (PNs). This represents one of the most striking examples of targeting specificity in developmental neurobiology. Recent studies have uncovered central roles of transmembrane and secreted proteins in organizing this one-to-one connection specificity in the olfactory system. Here, we review recent advances in the understanding of how this wiring specificity is genetically controlled and focus on the mechanisms by which transmembrane and secreted proteins regulate different stages of the Drosophila olfactory circuit assembly in a coordinated manner. We also discuss how combinatorial coding, redundancy, and error-correcting ability could contribute to constructing a complex neural circuit in general. PMID:24395823

  1. Converting Existing Copper Wire Firing System to a Fiber Optically Controlled Firing System for Electromagnetic Pulsed Power Experiments

    Science.gov (United States)

    2017-12-19

    Firing System for Electromagnetic Pulsed Power Experiments by Robert Borys Jr and Colby Adams Approved for public release...2017 4. TITLE AND SUBTITLE Converting Existing Copper Wire Firing System to a Fiber-Optically Controlled Firing System for Electromagnetic Pulsed ...US Army Research Laboratory Converting Existing Copper Wire Firing System to a Fiber-Optically Controlled Firing System for Electromagnetic

  2. Wire in the Cable-Driven System of Surgical Robot

    Science.gov (United States)

    Wang, X. F.; Lv, N.; Mu, H. Z.; Xue, L. J.

    2017-07-01

    During the evolution of the surgical robot, cable plays an important role. It translates motion and force precisely from surgeon’s hand to the tool’s tips. In the paper, the vertical wires, the composition of cable, are mathematically modeled from a geometric point of view. The cable structure and tension are analyzed according to the characteristics of wire screw twist. The structural equations of the wires in different positions are derived for both non-bent cable and bent cable, respectively. The bending moment formula of bent cable is also obtained. This will help researchers find suitable cable and design more matched pulley.

  3. 14 CFR 129.111 - Electrical wiring interconnection systems (EWIS) maintenance program.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Electrical wiring interconnection systems (EWIS) maintenance program. 129.111 Section 129.111 Aeronautics and Space FEDERAL AVIATION... ENGAGED IN COMMON CARRIAGE Continued Airworthiness and Safety Improvements § 129.111 Electrical wiring...

  4. Virtual Instrument Systems in Reality (VISIR) for Remote Wiring and Measurement of Electronic Circuits on Breadboard

    Science.gov (United States)

    Tawfik, M.; Sancristobal, E.; Martin, S.; Gil, R.; Diaz, G.; Colmenar, A.; Peire, J.; Castro, M.; Nilsson, K.; Zackrisson, J.; Hakansson, L.; Gustavsson, I.

    2013-01-01

    This paper reports on a state-of-the-art remote laboratory project called Virtual Instrument Systems in Reality (VISIR). VISIR allows wiring and measuring of electronic circuits remotely on a virtual workbench that replicates physical circuit breadboards. The wiring mechanism is developed by means of a relay switching matrix connected to a PCI…

  5. The Influence of Wiring Economy on Nervous System Evolution.

    Science.gov (United States)

    Wang, Irving E; Clandinin, Thomas R

    2016-10-24

    The activity and maintenance of neurons requires substantial metabolic energy, resulting in selective pressure to decrease resource consumption by the nervous system. The wiring economy principle proposes that animals have evolved mechanisms that wire circuits efficiently by minimizing neurite length. Computational modeling of neuronal morphology, microcircuit organization, and neural networks reveals that wiring economy is a significant determinant of nervous system layout. The strategies for reducing wiring costs are shared across phyla and point to the possibility of generalizable rules that specify the development of efficient nervous systems. As the developmental mechanisms underpinning wiring economy are only now being elucidated, whether the molecular basis of this phenomenon is the result of conserved genetic programs or convergent evolution remains to be determined. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Toward a Reduced-Wire Readout System for Ultrasound Imaging

    Science.gov (United States)

    Lim, Jaemyung; Arkan, Evren F.; Degertekin, F. Levent; Ghovanloo, Maysam

    2015-01-01

    We present a system-on-a-chip (SoC) for use in high-frequency capacitive micromachined ultrasonic transducer (CMUT) imaging systems. This SoC consists of trans-impedance amplifiers (TIA), delay locked loop (DLL) based clock multiplier, quadrature sampler, and pulse width modulator (PWM). The SoC down converts RF echo signal to baseband by quadrature sampling which facilitates modulation. To send data through a 1.6 m wire in the catheter which has limited bandwidth and is vulnerable to noise, the SoC creates a pseudo-digital PWM signal which can be used for back telemetry or wireless readout of the RF data. In this implementation, using a 0.35-μm std. CMOS process, the TIA and single-to-differential (STD) converter had 45 MHz bandwidth, the quadrature sampler had 10.1 dB conversion gain, and the PWM had 5-bit ENoB. Preliminary results verified front-end functionality, and the power consumption of a TIA, STD, quadrature sampler, PWM, and clock multiplier was 26 mW from a 3 V supply. PMID:25571135

  7. An investigation of a coincidence detection system for an all-digital small animal PET scanner

    International Nuclear Information System (INIS)

    Liu Wei; Chen Yuanbao; Long Anwen; Chen Xin; Wu Zhongyi; Zhang Yongxue; Xie Qingguo

    2013-01-01

    Objective: To investigate and design a coincidence detection system for an all-digital small animal PET scanner and evaluate its preliminary performance properties. Methods: This coincidence module adopted a coincidence identification mode based on singles data in list-mode.Using digital signal processing technology, energy calibration, crystal identification, timing alignment and coincidence events extraction were performed on singles data in list-mode. The obtained data could be used for image reconstruction. Results: The 13 × 13 crystal array was well recognized by the position histogram of one lutetium yttrium orthosilicate (LYSO) crystal block. In the coincidence timing histogram of the micro-Derenzo phantom, 1.36 ns full width at half maximum was obtained. The rods with a diameter of 1.2 mm were clearly displayed in the reconstructed image of the micro-Derenzo phantom. Conclusion: The coincidence module can provide satisfactory performance to meet the design needs of an all-digital small animal PET scanner. (authors)

  8. A One Chip Hardened Solution for High Speed SpaceWire System Implementations. Session: Components

    Science.gov (United States)

    Marshall, Joseph R.; Berger, Richard W.; Rakow, Glenn P.

    2007-01-01

    An Application Specific Integrated Circuit (ASIC) that implements the SpaceWire protocol has been developed in a radiation hardened 0.25 micron CMOS technology. This effort began in March 2003 as a joint development between the NASA Goddard Space Flight Center (GSFC) and BAE Systems. The BAE Systems SpaceWire ASIC is comprised entirely of reusable core elements, many of which are already flight-proven. It incorporates a router with 4 SpaceWire ports and two local ports, dual PC1 bus interfaces, a microcontroller, 32KB of internal memory, and a memory controller for additional external memory use. The SpaceWire cores are also reused in other ASICs under development. The SpaceWire ASIC is planned for use on the Geostationary Operational Environmental Satellites (GOES)-R, the Lunar Reconnaissance Orbiter (LRO) and other missions. Engineering and flight parts have been delivered to programs and users. This paper reviews the SpaceWire protocol and those elements of it that have been built into the current and next SpaceWire reusable cores and features within the core that go beyond the current standard and can be enabled or disabled by the user. The adaptation of SpaceWire to BAE Systems' On Chip Bus (OCB) for compatibility with the other reusable cores will be reviewed and highlighted. Optional configurations within user systems and test boards will be shown. The physical implementation of the design will be described and test results from the hardware will be discussed. Application of this ASIC and other ASICs containing the SpaceWire cores and embedded microcontroller to Plug and Play and reconfigurable implementations will be described. Finally, the BAE Systems roadmap for SpaceWire developments will be updated, including some products already in design as well as longer term plans.

  9. Fault Diagnostics in Power Electronics Based Brake-by-Wire Systems

    Science.gov (United States)

    2006-05-22

    brake-by-wire system as soon as they occur. We developed a brake-by-wire ( BBW ) system model using Simplorer software that implements the full control...the BBW system. It has the capabilities of detecting faulty conditions immediately after they occur, and pinpointing to specific faulty conditions...within less than 0.02s on the bench setup BBW . The performance of the hierarchical fuzzy diagnostic system is also compared with two other fuzzy

  10. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    Directory of Open Access Journals (Sweden)

    Mustafa Demir

    2018-02-01

    Full Text Available Objective: The aim of the present study was to compare the performance of positron emission tomography (PET component of PET/computed tomography (CT with new emerging PET/magnetic resonance (MR of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. Results: The findings of this study demonstrated superior sensitivity (~ 4 folds of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9% compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. Conclusion: It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  11. U.S. Navy Wire-Rope Handbook. Volume 1. Design and Engineering of Wire-Rope Systems

    Science.gov (United States)

    1976-01-01

    percent nickel and are designated "Type 304 " and "Type 302" by the American Iron and Steel Institute ( AISI ). Type 304 stainless steel rope may be...from AISI Specifica- tion XYZ14 on Alloy Steel Wire) .... ............ ... 3-2 3-2. Typical Load-Elongation Behavior of Wire Rope .... ...... 3-9 3...Cosecants .......... ................... ... 10-S 10-11. Physical and Mechanical Properties of Wire ............ . .. 10-10 10-12. Wire Gauges

  12. Progress in American Superconductor’s HTS wire and optimization for fault current limiting systems

    Energy Technology Data Exchange (ETDEWEB)

    Malozemoff, Alexis P., E-mail: amalozemoff@amsc.com

    2016-11-15

    Highlights: • AMSC HTS wire critical current needed for rotating machinery is doubled by 16 MeV Au irradiation. • Nonuniformity of HTS wires in power devices causes hot spot formation during power system faults. • Lower normal-state resistivity and critical current lower HTS wire hot spot heating during faults. • HTS wire hot spot heating in HTS cables during faults must stay below lN{sub 2} bubble nucleation point. • HTS wire can be designed to meet hot spot heating limits in fault current limiting cables. - Abstract: American Superconductor has developed composite coated conductor tape-shaped wires using high temperature superconductor (HTS) on a flexible substrate with laminated metal stabilizer. Such wires enable many applications, each requiring specific optimization. For example, coils for HTS rotating machinery require increased current density J at 25–50 K. A collaboration with Argonne, Brookhaven and Los Alamos National Laboratories and several universities has increased J using an optimized combination of precipitates and ion irradiation defects in the HTS. Major commercial opportunities also exist to enhance electric power grid resiliency by linking substations with distribution-voltage HTS power cables [10]. Such links provide alternative power sources if one substation's transmission-voltage power is compromised. But they must also limit fault currents which would otherwise be increased by such distribution-level links. This can be done in an HTS cable, exploiting the superconductor-to-resistive transition when current exceeds the wires’ critical J. A key insight is that such transitions are usually nonuniform; so the wire must be designed to prevent localized hot spots from damaging the wire or even generating gas bubbles in the cable causing dielectric breakdown. Analysis shows that local heating can be minimized by increasing the composite tape's total thickness, decreasing its total resistance in the normal state and

  13. The Mechatronic System Design Of Ultrasonic Scanner For Inservice Inspection Of Research Reactor

    Science.gov (United States)

    Handono, Khairul; Kristedjo, K.; Awwaluddin, M.; Shobary, Ihsan

    2018-02-01

    The mechatronic system design of ultrasonic scanner for inservices inspection of Research Reactor has been conducted. The requirement designed must be reliable operated, safety to personnel and equipments, ease of maintenance and operation, protection of equipment mechanically, interchangeability of equipments and addition of the several model of probe immersion ultrasonic tranducer. In order to achieve the above goals and obtain the desired results, a mechatronic design based on mechanical and electronic practical experiences will be needed. In this paper consist of the mechanical design and the system mechanical movement using stepper motor control. The criteria and the methods of designs of mechanical and electronic equipments of the system have been discussed and investigated. A mechanical and instrumentation control system drawing and requirement of design will be presented as the outcome of the design. The designed of mechanical system is consequently simulated by solidwork software. The intention of the above research is to create solutions in different ways of inservice inspection of integrity of Reactor.

  14. Steer-by-wire system for the Motor-Kart vehicle of FH Cologne University; Steer-by-Wire-Lenkung fuer den Motor-Kart der FH Koeln

    Energy Technology Data Exchange (ETDEWEB)

    Baum, H. [Fluidon GmbH, Aachen (Germany); Ulrich, H. [FH Koeln (Germany). Inst. fuer Fahrzeugtechnik; Hermanns, O. [LMS Deutschland GmbH, Kaiserslautern (Germany)

    2005-12-01

    In the course of semester projects, students of FH Cologne, Institute of Motor Car Engineering, get their first experience with the increasingly complex development processes of modern vehicle systems. Using the example of a steer-by-wire system, the contribution outlines the steps taken by the students. One of the key elements of the project was the development of the steer-by-wire control by coupling the control unit to the detailed simulation model of the Motor-Kart vehicle. (orig.)

  15. High-speed micro electrode tool fabrication by a twin-wire EDM system

    International Nuclear Information System (INIS)

    Sheu, Dong-Yea

    2008-01-01

    This paper describes a new machining process which combines twin-electro-wire together with two electro discharge circuits to rapidly fabricate micro electrode tools. The results show that transistor electro discharge and RC electro discharge circuits coexist to fabricate micro tools with rough and finish machining both on the same machine. Compared to conventional wire electro discharge grinding (WEDG) technology, a twin-wire EDM system that combines rough and finish machining into one process allows the efficient fabrication of micro tools. This high-speed micro tool fabrication process can be applied not only to micro electrode machining but also to micro punching tool and micro probing tips machining

  16. Evaluation of Clouds and the Earth's Radiant Energy System (CERES) Scanner Pointing Accuracy using a Coastline Detection System

    Science.gov (United States)

    Currey, Chris; Smith, Lou; Neely, Bob

    1998-01-01

    Clouds and the Earth's Radiant Energy System (CERES) is a National Aeronautics and Space Administration (NASA) investigation to examine the role of clouds in the radiative energy flow through the Earth-atmosphere system. The first CERES scanning radiometer was launched on November 27, 1997 into a 35 inclination, 350 km altitude orbit, on the Tropical Rainfall Measuring Mission (TRMM) spacecraft. The CERES instrument consists of a three channel scanning broadband radiometer. The spectral bands measure shortwave (0.3 - 5 microns), window (8 - 12 microns), and total (0.3 - 100 microns) radiation reflected or emitted from the Earth-atmosphere system. Each Earth viewing measurement is geolocated to the Earth fixed coordinate system using satellite ephemeris, Earth rotation and geoid, and instrument pointing data. The interactive CERES coastline detection system is used to assess the accuracy of the CERES geolocation process. By analyzing radiative flux gradients at the boundaries of ocean and land masses, the accuracy of the scanner measurement locations may be derived for the CERES/TRMM instrument/satellite system. The resulting CERES measurement location errors are within 10% of the nadir footprint size. Precise pointing knowledge of the Visible and Infrared Scanner (VIRS) is required for convolution of cloud properties onto the CERES footprint; initial VIRS coastline results are included.

  17. MEMS scanner mirror based system for retina scanning and in eye projection

    Science.gov (United States)

    Woittennek, Franziska; Knobbe, Jens; Pügner, Tino; Dallmann, Hans-Georg; Schelinski, Uwe; Grüger, Heinrich

    2015-02-01

    Many applications could benefit from miniaturized systems to scan blood vessels behind the retina in the human eye, so called "retina scanning". This reaches from access control to sophisticated security applications and medical devices. High volume systems for consumer applications require low cost and a user friendly operation. For example this includes no need for removal of glasses and self-adjustment, in turn guidance of focus and point of attraction by simultaneous projection for the user. A new system has been designed based on the well-known resonantly driven 2-d scanner mirror of Fraunhofer IPMS. A combined NIR and VIS laser system illuminates the eye through an eye piece designed for an operating distance allowing the use of glasses and granting sufficient field of view. This usability feature was considered to be more important than highest miniaturization. The modulated VIS laser facilitates the projection of an image directly onto the retina. The backscattered light from the continuous NIR laser contains the information of the blood vessels and is detected by a highly sensitive photo diode. A demonstrational setup has been realized including readout and driving electronics. The laser power was adjusted to an eye-secure level. Additional security features were integrated. Test measurements revealed promising results. In a first demonstration application the detection of biometric pattern of the blood vessels was evaluated for issues authentication in.

  18. Aircraft scanner data availability via the version 0 Information Management System

    Science.gov (United States)

    Mah, G. R.

    1995-01-01

    As part of the Earth Observing System Data and Information System (EOSDIS) development, NASA and other government agencies have developed an operational prototype of the Information Management System (IMS). The IMS provides access to the data archived at the Distributed Active Archive Centers (DAAC's) that allows users to search through metadata describing the (image) data. Criteria based on sensor name or type, date and time, and geographic location are used to search the archive. Graphical representations of coverage and browse images are available to further refine a user's selection. previously, the EROS Data Center (EDC) DAAC had identified the Advanced SOlid-state Array Spectrometer (ASAS), Airborne Visible and infrared Imaging Spectrometer (AVIRIS), NS-001, and Thermal Infrared Multispectral Scanner (TIMS) as precursor data sets similar to those the DAAC will handle in the Earth Observing System era. Currently, the EDC DAAC staff, in cooperation with NASA, has transcribed TIMS, NS-001, and Thematic Mapper Simulation (TMS) data from Ames Research Center and also TIMS data from Stennis Space Center. During the transcription process, the IMS metadata and browse images were created to populate the inventory at the EDC DAAC. These data sets are now available in the IMS and may be requested from the any of the DAAC's via the IMS.

  19. The design of the CMOS wireless bar code scanner applying optical system based on ZigBee

    Science.gov (United States)

    Chen, Yuelin; Peng, Jian

    2008-03-01

    The traditional bar code scanner is influenced by the length of data line, but the farthest distance of the wireless bar code scanner of wireless communication is generally between 30m and 100m on the market. By rebuilding the traditional CCD optical bar code scanner, a CMOS code scanner is designed based on the ZigBee to meet the demands of market. The scan system consists of the CMOS image sensor and embedded chip S3C2401X, when the two dimensional bar code is read, the results show the inaccurate and wrong code bar, resulted from image defile, disturber, reads image condition badness, signal interference, unstable system voltage. So we put forward the method which uses the matrix evaluation and Read-Solomon arithmetic to solve them. In order to construct the whole wireless optics of bar code system and to ensure its ability of transmitting bar code image signals digitally with long distances, ZigBee is used to transmit data to the base station, and this module is designed based on image acquisition system, and at last the wireless transmitting/receiving CC2430 module circuit linking chart is established. And by transplanting the embedded RTOS system LINUX to the MCU, an applying wireless CMOS optics bar code scanner and multi-task system is constructed. Finally, performance of communication is tested by evaluation software Smart RF. In broad space, every ZIGBEE node can realize 50m transmission with high reliability. When adding more ZigBee nodes, the transmission distance can be several thousands of meters long.

  20. Monitoring tooth demineralization using a cross polarization optical coherence tomographic system with an integrated MEMS scanner

    Science.gov (United States)

    Fried, Daniel; Staninec, Michal; Darling, Cynthia; Kang, Hobin; Chan, Kenneth

    2012-01-01

    New methods are needed for the nondestructive measurement of tooth demineralization and remineralization to monitor the progression of incipient caries lesions (tooth decay) for effective nonsurgical intervention and to evaluate the performance of anti-caries treatments such as chemical treatments or laser irradiation. Studies have shown that optical coherence tomography (OCT) has great potential to fulfill this role since it can be used to measure the depth and severity of early lesions with an axial resolution exceeding 10-μm, it is easy to apply in vivo and it can be used to image the convoluted topography of tooth occlusal surfaces. In this paper we present early results using a new cross-polarization OCT system introduced by Santec. This system utilizes a swept laser source and a MEMS scanner for rapid acquisition of cross polarization images. Preliminary studies show that this system is useful for measurement of the severity of demineralization on tooth surfaces and for showing the spread of occlusal lesions under the dentinal-enamel junction.

  1. Experimental research on laser tracking system with galvanometer scanner for measuring spatial coordinates of moving target

    Science.gov (United States)

    Wang, Jia; Hu, Zhaohui; Liu, Yongdong; Liang, Jinwen

    2000-10-01

    The spatial position of industrial object, such as robot end- effector, is an important geometric parameter whose accuracy determines whether robot can perform accurately. Therefore, we have established a laser tracking and coordinate measuring system with galvanometer scanner for high accuracy, large range, non- contact, and spatial dynamic measurement. In this paper, the laser tracking system and its setup are illuminated at first. Then, the formulae for calculating coordinates are deduced, and the calibration method of the initial distance from tracking mirror to target is presented. After that, two preliminary experiments in different distances are described. One is on CMM; the other is with grating ruler as reference. In the former, the maximum measurement error of coordinates is 70micrometers and the maximum error of length is 35micrometers in the 85x100x100mm3 measurement volume, and in the 1m initial distance. In the later, the maximum error of length is 140micrometers in the range of 480mm, and in the 5m initial distance. At the end of the paper, the error sources are analyzed and simulated.

  2. [Digital volume tomography : Dedicated scanner and cone beam CT with C‑arm systems].

    Science.gov (United States)

    Fiebich, M; Weber, D

    2018-03-01

    Digital volume tomography (DVT) and cone-beam computed tomography (CT) with C‑arm systems have become established three-dimensional imaging systems as an alternative to CT in some application areas. The technology of the systems is well developed so that they have become a competing method to CT imaging in terms of image quality and radiation exposure. An advantage is the better spatial resolution, preferably with dedicated scanner systems, especially in the z direction. The radiation exposure of CT, cone beam CT and DVT are comparable, if the exposure parameter in CT imaging can be adjusted to the lower exposure levels. Advantages of these systems are that they can be used for imaging in a better workflow or to acquire images under conditions not possible in CT, e. g. imaging under stress in orthopedics or to take images in the corona technique with a horizontal gantry in cone-beam CT mammography PRACTICAL RECOMMENDATIONS: The use of three-dimensional imaging is becoming more frequent and will replace planar radiography in additional clinical situations. The three-dimensional imaging without superpositioning of structures has advantages in the visibility of structures and the spatial relation to other organs and structures. In guidelines and recommendations, the number of recommendations given for the use of three-dimensional imaging is increasing. This leads to a small increase in the radiation exposure of patients, a trend which is reflected in the annual reports of the Federal Office for Radiation Protection.

  3. Wire rope tension control of hoisting systems using a robust nonlinear adaptive backstepping control scheme.

    Science.gov (United States)

    Zhu, Zhen-Cai; Li, Xiang; Shen, Gang; Zhu, Wei-Dong

    2018-01-01

    This paper concerns wire rope tension control of a double-rope winding hoisting system (DRWHS), which consists of a hoisting system employed to realize a transportation function and an electro-hydraulic servo system utilized to adjust wire rope tensions. A dynamic model of the DRWHS is developed in which parameter uncertainties and external disturbances are considered. A comparison between simulation results using the dynamic model and experimental results using a double-rope winding hoisting experimental system is given in order to demonstrate accuracy of the dynamic model. In order to improve the wire rope tension coordination control performance of the DRWHS, a robust nonlinear adaptive backstepping controller (RNABC) combined with a nonlinear disturbance observer (NDO) is proposed. Main features of the proposed combined controller are: (1) using the RNABC to adjust wire rope tensions with consideration of parameter uncertainties, whose parameters are designed online by adaptive laws derived from Lyapunov stability theory to guarantee the control performance and stability of the closed-loop system; and (2) introducing the NDO to deal with uncertain external disturbances. In order to demonstrate feasibility and effectiveness of the proposed controller, experimental studies have been conducted on the DRWHS controlled by an xPC rapid prototyping system. Experimental results verify that the proposed controller exhibits excellent performance on wire rope tension coordination control compared with a conventional proportional-integral (PI) controller and adaptive backstepping controller. Copyright © 2017 ISA. All rights reserved.

  4. The wiring diagram of a glomerular olfactory system

    Science.gov (United States)

    Berck, Matthew E; Khandelwal, Avinash; Claus, Lindsey; Hernandez-Nunez, Luis; Si, Guangwei; Tabone, Christopher J; Li, Feng; Truman, James W; Fetter, Rick D; Louis, Matthieu; Samuel, Aravinthan DT; Cardona, Albert

    2016-01-01

    The sense of smell enables animals to react to long-distance cues according to learned and innate valences. Here, we have mapped with electron microscopy the complete wiring diagram of the Drosophila larval antennal lobe, an olfactory neuropil similar to the vertebrate olfactory bulb. We found a canonical circuit with uniglomerular projection neurons (uPNs) relaying gain-controlled ORN activity to the mushroom body and the lateral horn. A second, parallel circuit with multiglomerular projection neurons (mPNs) and hierarchically connected local neurons (LNs) selectively integrates multiple ORN signals already at the first synapse. LN-LN synaptic connections putatively implement a bistable gain control mechanism that either computes odor saliency through panglomerular inhibition, or allows some glomeruli to respond to faint aversive odors in the presence of strong appetitive odors. This complete wiring diagram will support experimental and theoretical studies towards bridging the gap between circuits and behavior. DOI: http://dx.doi.org/10.7554/eLife.14859.001 PMID:27177418

  5. 47 CFR 68.215 - Installation of other than “fully protected” system premises wiring that serves more than four...

    Science.gov (United States)

    2010-10-01

    ... system premises wiring that serves more than four subscriber access lines. 68.215 Section 68.215... other than “fully protected” system premises wiring that serves more than four subscriber access lines. (a) Types of wiring authorized—(1) Between equipment entities. Unprotected premises wiring, and...

  6. Beam intensity scanner system for three dimensional dose verification of IMRT

    International Nuclear Information System (INIS)

    Vahc, Young W.; Kwon, Ohyun; Park, Kwangyl; Park, Kyung R.; Yi, Byung Y.; Kim, Keun M.

    2003-01-01

    Patient dose verification is clinically one of the most important parts in the treatment delivery of radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in IMRT. Here we present beam intensity scanner (BInS) system for the pre-treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom-made software for dose conversion of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6 MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera-based scintillator (DVCS) will be processed by our custom made software to reproduce 3D- relative dose distribution. For the intensity modulated beam (IMB), the BInS calculates absorbed dose in absolute beam fluence which is used for the patient dose distribution. Using BInS, we performed various measurements related to IMRT and found the following: (1) The 3D-dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimation of dynamic and/or step MLC system. This is mostly due to leaf transmission, leaf penumbra scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multi leaf opening. These phenomena result in a fluence distribution that can be substantially different from the initial and calculated intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT. (author)

  7. Characteristics of the Sliding Electric Contact of Pantograph/Contact Wire Systems in Electric Railways

    Directory of Open Access Journals (Sweden)

    Guangning Wu

    2017-12-01

    Full Text Available The sliding electric contact of pantograph/contact wire systems plays a significant part in the current collection stability and operation life of pantograph/contact wire systems. This paper addresses the evolutionary process of sliding electric contact of pantograph/contact wire systems by analyzing three key characteristics including contact resistance, temperature distribution and microstructure. The influence of electric current on contact resistance was interpreted. Furthermore, the evolution of the spatial temperature distribution of the carbon strip was obtained in the zigzag movement, while the dominant role of electric effect in temperature rise was demonstrated. In the end, the wear morphology differences under pure friction and current-carrying conditions were analyzed. The formation of radial cracks was illustrated and its influenced on the wear process was discussed.

  8. Microscopy system of atomic force based on a digital optical reading unit and a buzzer-scanner

    International Nuclear Information System (INIS)

    Dabirian, R.; Loza M, D.; Wang, W. M.; Hwu, E. T.

    2015-01-01

    An astigmatic detection system (Ads) based on a compact disk/digital-versatile-disk (Cd-DVD) astigmatic optical pickup unit is presented. It can achieve a resolution better than 0.3 nm in detection of the vertical displacement and is able to detect the two-dimensional angular tilt of the object surface. Furthermore, a novel scanner design actuated by piezoelectric disk buzzers is presented. The scanner is composed of a quad-rod actuation structure and several piezoelectric disks. It can be driven directly with low-voltage and low-current sources, such as analogue outputs of a data acquisition card and enables a sufficient scanning range of up to μm. In addition, an economic, high-performance streamlined atomic force microscopy (AFM) was constructed, using the buzzer-scanner to move the sample relative to the probe, and using a Cd/DVD optical pickup unit to detect the mechanical resonance of a micro fabricated cantilever. The performance of the AFM is evaluated. The high sensitivity and high bandwidth of the detection system makes the equipment suitable for characterizing nano scale elements. An AFM using our detection system for detecting the deflection of micro fabricated cantilevers can resolve individual atomic steps on graphite surfaces. (Author)

  9. Insulator and Clerance Requirements in Overhead Line Transmission Systems without Shield Wires

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    This paper theoretically examines the required insulation lengths and clearances in 400 kV overhead line systems when not making use of ground wires as lightning protection. The influence of lightning strikes to the system is investigated based on dynamic transmission line simulations of a 400 kV...

  10. Multi-wire chamber system for heavy ion beam monitoring at the Bevalac

    International Nuclear Information System (INIS)

    Cuperus, J.; Morgado, R.

    1975-03-01

    Horizontal and vertical integrated beam-current profiles are generated by a system of multi-wire chambers (32 wires/profile) operating in either the ionization or proportional mode. Sixteen distinct displays (1024 words) are digitally stored and any four may be simultaneously displayed. A new display can be generated at 64 ms intervals. A central control unit selects the mode of operation, the amount of delay after an appropriate trigger, the chamber integration time, and the particular chambers to be displayed. Operating in the proportional mode, the system can detect relativistic heavy-ion beam intensities as low as 10 4 charges cm -2 sec -1 . (U.S.)

  11. Mechanization of and experience with a triplex fly-by-wire backup control system

    Science.gov (United States)

    Lock, W. P.; Petersen, W. R.; Whitman, G. B.

    1976-01-01

    A redundant three axis analog control system was designed and developed to back up a digital fly by wire control system for an F-8C airplane. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum displacement (force) side stick. The operational reliability of the F-8 digital fly by wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.

  12. Design of power cable grounding wire anti-theft monitoring system

    Science.gov (United States)

    An, Xisheng; Lu, Peng; Wei, Niansheng; Hong, Gang

    2018-01-01

    In order to prevent the serious consequences of the power grid failure caused by the power cable grounding wire theft, this paper presents a GPRS based power cable grounding wire anti-theft monitoring device system, which includes a camera module, a sensor module, a micro processing system module, and a data monitoring center module, a mobile terminal module. Our design utilize two kinds of methods for detecting and reporting comprehensive image, it can effectively solve the problem of power and cable grounding wire box theft problem, timely follow-up grounded cable theft events, prevent the occurrence of electric field of high voltage transmission line fault, improve the reliability of the safe operation of power grid.

  13. Initial Results of Testing a Multilayer Laser Scanner in a Collision Avoidance System for Light Rail Vehicles

    Directory of Open Access Journals (Sweden)

    Murat Lüy

    2018-03-01

    Full Text Available This paper presents an application to detect and track obstacles using a multilayer laser scanner. The goal of the detection system is to develop collision avoidance for the Light Rail Vehicle (LRV. The laser scanner, which is mounted in front of the tram, collects information in a four-scan plane. The object recognition and tracking module, which is composed of a three sub-modules segmentation, classification, and Kalman Filter tracking, was carried out on the raw data. Thus, data were provided for collision avoidance module. The proposed system was applied to a tram named “Silkworm” which is manufactured by Durmazlar Machine Inc. (Bursa, Turkey and initial experimental tests have been conducted at the facilities of Durmazlar Machine Inc. in the city of Bursa, Turkey. This study aims to illustrate parts of the possible tests that can be carried out and to share with the scientific community an important application of multilayer laser scanners, although in the initial implementation phase, in urban rail transportation.

  14. Scanner image quality profiling

    Science.gov (United States)

    Cui, Chengwu

    2009-01-01

    When using a document scanner, scan image quality is often unknown to the end user of the scanned image. Document scanners may employ different imaging technologies that can result in different image characteristics. Variability of scanner parts and the manufacturing process may also create variability of the scanned image quality from machine to machine. Image quality of the same scanner may also change as it ages and becomes contaminated. If the scanned image is used for human viewing, the resulting image quality variability may not be mission critical other than being a visual annoyance because the human visual system has superb adaptation and segmentation capability. However, if the scanned image is used for machine recognition or for printing, the image quality variability may become important and even mission critical. Here we propose a framework to profile the scanner image quality and tag the scanned image with the IQ profile. We review the potential quantified aspects of scan image quality and propose a method of characterization with examples.

  15. Design of measuring system for wire diameter based on sub-pixel edge detection algorithm

    Science.gov (United States)

    Chen, Yudong; Zhou, Wang

    2016-09-01

    Light projection method is often used in measuring system for wire diameter, which is relatively simpler structure and lower cost, and the measuring accuracy is limited by the pixel size of CCD. Using a CCD with small pixel size can improve the measuring accuracy, but will increase the cost and difficulty of making. In this paper, through the comparative analysis of a variety of sub-pixel edge detection algorithms, polynomial fitting method is applied for data processing in measuring system for wire diameter, to improve the measuring accuracy and enhance the ability of anti-noise. In the design of system structure, light projection method with orthogonal structure is used for the detection optical part, which can effectively reduce the error caused by line jitter in the measuring process. For the electrical part, ARM Cortex-M4 microprocessor is used as the core of the circuit module, which can not only drive double channel linear CCD but also complete the sampling, processing and storage of the CCD video signal. In addition, ARM microprocessor can complete the high speed operation of the whole measuring system for wire diameter in the case of no additional chip. The experimental results show that sub-pixel edge detection algorithm based on polynomial fitting can make up for the lack of single pixel size and improve the precision of measuring system for wire diameter significantly, without increasing hardware complexity of the entire system.

  16. Cam Mover Alignment System positioning with the Wire Positioning with the Wire Position Sensor Feedback for CLIC

    CERN Document Server

    AUTHOR|(CDS)2077936; Mainaud Durand, Helene; Kostka, Z.S.

    2016-01-01

    Compact Linear Collider (CLIC) is a study of an electron-positron collider with nominal energy of 3 TeV and luminosity of 2 ∙ 1034 cm-2s-1. The luminosity goal leads to stringent alignment requirements for single quadrupole magnets. Vertical and lateral offset deviations with regards to a given orbit reference in both ends of a quadrupole shall be below 1 μm and quadrupole roll deviation shall be below 100 μrad. Translation in the direction of particle beam is not controlled but mechanically locked. A parallel kinematic platform based on cam movers was chosen as system for detailed studies. Earlier studies have shown that cam movers can reach the CLIC requirements through an iterative process. The paper presents new modular off-the-shelf control electronics and software including three optional positioning algorithms based on iterations as well as a more advanced algorithm which can reach target position in one movement. The advanced algorithm reads wire position sensors (WPS), calculates quadrupole orien...

  17. Calculating modes of quantum wire systems using a finite difference technique

    Directory of Open Access Journals (Sweden)

    T Mardani

    2013-03-01

    Full Text Available  In this paper, the Schrodinger equation for a quantum wire is solved using a finite difference approach. A new aspect in this work is plotting wave function on cross section of rectangular cross-sectional wire in two dimensions, periodically. It is found that the correct eigen energies occur when wave functions have a complete symmetry. If the value of eigen energy has a small increase or decrease in neighborhood of the correct energy the symmetry will be destroyed and aperturbation value at the first of wave function will be observed. In addition, the demand on computer memory varies linearly with the size of the system under investigation.

  18. The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses.

    Science.gov (United States)

    Shimizu, Sakura; Shinya, Akikazu; Kuroda, Soichi; Gomi, Harunori

    2017-07-26

    The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.

  19. Differences in the force system delivered by different beta-titanium wires in elaborate designs

    Directory of Open Access Journals (Sweden)

    Renato Parsekian Martins

    2015-12-01

    Full Text Available Abstract Objective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. Methods: A total of 40 T-loop springs (TLS hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1, BETA FLEXYTM (G2, BETA III WIRETM (G3 and BETA CNATM (G4. Forces and moments were recorded by a moment transducer, coupled to a digital extensometer indicator adapted to a testing machine, every 0.5 mm of deactivation from 5 mm of the initial activation. The moment-to-force (MF ratio, the overlapping of the vertical extensions of the TLSs and the load-deflection (LD ratio were also calculated. To complement the results, the Young's module (YM of each wire was determined by the slope of the load-deflection graph of a tensile test. The surface chemical composition was also evaluated by an energy dispersive X-ray fluorescence spectrometer. Results: All groups, except for G2, produced similar force levels initially. G3 produced the highest LD rates and G1 and G4 had similar amounts of overlap of the vertical extensions of the TLSs in "neutral position". G1 and G3 delivered the highest levels of moments, and G2 and G3 produced the highest MF ratios. b-Ti wires from G3 produced the highest YM and all groups showed similar composition, except for G2. Conclusion: The four beta-titanium wires analyzed produced different force systems when used in a more elaborate design due to the fact that each wire responds differently to bends.

  20. Quasiparticle properties of a coupled quantum-wire electron-phonon system

    DEFF Research Database (Denmark)

    Hwang, E. H.; Hu, Ben Yu-Kuang; Sarma, S. Das

    1996-01-01

    We study leading-order many-body effects of longitudinal-optical phonons on electronic properties of one-dimensional quantum-wire systems. We calculate the quasiparticle properties of a weakly polar one-dimensional electron gas in the presence of both electron-phonon and electron-electron interac...

  1. Analysis of electrical explosion of wire systems for the production of ...

    Indian Academy of Sciences (India)

    (Grassian 2008). So research in the direction of the development of better experimental system is the demand of the present situation. Many alternative methods have been proposed to realize production of particles. Electrical explosion of wire method (EEW) is one of the vapour phase methods in which particles are ...

  2. An investigation of the dose distribution from low dose rate Ir-192 Wires in the triangular implants of the paris system using polymer gel dosimetry

    International Nuclear Information System (INIS)

    Rahimi, A.; Hashemi, B.; Zahmatkesh, M. H.; Jaberi, R.; Sheibani, Sh.

    2011-01-01

    Polymer gels are modern dosimeters providing three dimensional dose distributions. These dosimeters can be used in brachytherapy in which the tumor dimension is relatively small and the dose gradient is high. In this study, the ability of the MAGICA polymer gel was investigated for assessing the absolute dose values as well as the dose distribution of low dose rate Ir-192 wires in interstitial brachytherapy based in triangular implants of the Paris system. Material and Methods: A suitable phantom was made from Perspex. Glass tubes were used as the external tubes for holding the Ir-192 wires in the phantom. The MAGICA polymer gel was made and placed in the phantom. The phantom and the calibration tubes were irradiated using low dose rate Ir-192 wires and a Co-60 teletherapy unit respectively. They were subsequently imaged using an MRI scanner. The R2 (=1/T 2) maps were extracted from several sequential T 2-weighted MRI images. The dose values resulting from the polymer gel measurements at the reference points were compared with those from the common calculation method at the same points. In addition, the isodose curves resulting from gel dosimetry were compared with those from a brachytherapy treatment planning system (Flexiplan). Results: The average of the dose values measured with the gel at the reference points was 62.75% higher than those calculated at the same points. Investigating the isodose curves revealed that the maximum distance to agreement (DTAmax) between the isodoses resulting from the gel and those obtained from the treatment planning system was less than 3 mm at different dose levels. Discussion and Conclusion: Although the MAGICA gel indicates a higher absolute dose value than those calculated commonly, it can give the relative dose values accurately. Therefore, it can be recommended to be used for the assessment of dose distributions for the treatment of tissues as well as quality control of the treatment planning systems.

  3. An Investigation of the Dose Distribution from LDR Ir-192 Wires in the Triangular Implants of the Paris System using Polymer Gel Dosimetry

    Directory of Open Access Journals (Sweden)

    Azizollah Rahimi

    2010-12-01

    Full Text Available Introduction: Polymer gels are modern dosimeters providing three dimensional dose distributions. These dosimeters can be used in brachytherapy in which the tumor dimension is relatively small and the dose gradient is high. In this study, the ability of the MAGICA polymer gel was investigated for assessing the absolute dose values as well as the dose distribution of low dose rate (LDR Ir-192 wires in interstitial brachytherapy based in triangular implants of the Paris system. Material and Methods: A suitable phantom was made from Perspex. Glass tubes were used as the external tubes for holding the Ir-192 wires in the phantom. The MAGICA polymer gel was made and placed in the phantom. The phantom and the calibration tubes were irradiated using LDR Ir-192 wires and a Co-60 teletherapy unit respectively. They were subsequently imaged using an MRI scanner. The R2 (=1/T2 maps were extracted from several sequential T2-weighted MRI images. The dose values resulting from the polymer gel measurements at the reference points were compared with those from the common calculation method at the same points. In addition, the isodose curves resulting from gel dosimetry were compared with those from a brachytherapy treatment planning system (Flexiplan. Results: The average of the dose values measured with the gel at the reference points was 62.75% higher than those calculated at the same points. Investigating the isodose curves revealed that the maximum distance to agreement (DTAmax between the isodoses resulting from the gel and those obtained from the treatment planning system was less than 3 mm at different dose levels. Discussion and Conclusion: Although the MAGICA gel indicates a higher absolute dose value than those calculated commonly, it can give the relative dose values accurately. Therefore, it can be recommended to be used for the assessment of dose distributions for the treatment of tissues as well as quality control of the treatment planning systems.

  4. Scanner calibration revisited

    Directory of Open Access Journals (Sweden)

    Pozhitkov Alexander E

    2010-07-01

    Full Text Available Abstract Background Calibration of a microarray scanner is critical for accurate interpretation of microarray results. Shi et al. (BMC Bioinformatics, 2005, 6, Art. No. S11 Suppl. 2. reported usage of a Full Moon BioSystems slide for calibration. Inspired by the Shi et al. work, we have calibrated microarray scanners in our previous research. We were puzzled however, that most of the signal intensities from a biological sample fell below the sensitivity threshold level determined by the calibration slide. This conundrum led us to re-investigate the quality of calibration provided by the Full Moon BioSystems slide as well as the accuracy of the analysis performed by Shi et al. Methods Signal intensities were recorded on three different microarray scanners at various photomultiplier gain levels using the same calibration slide from Full Moon BioSystems. Data analysis was conducted on raw signal intensities without normalization or transformation of any kind. Weighted least-squares method was used to fit the data. Results We found that initial analysis performed by Shi et al. did not take into account autofluorescence of the Full Moon BioSystems slide, which led to a grossly distorted microarray scanner response. Our analysis revealed that a power-law function, which is explicitly accounting for the slide autofluorescence, perfectly described a relationship between signal intensities and fluorophore quantities. Conclusions Microarray scanners respond in a much less distorted fashion than was reported by Shi et al. Full Moon BioSystems calibration slides are inadequate for performing calibration. We recommend against using these slides.

  5. Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems.

    Science.gov (United States)

    Lim, Jaemyung; Tekes, Coskun; Degertekin, F Levent; Ghovanloo, Maysam

    2017-04-01

    Having intravascular ultrasound (IVUS) imaging capability on guide wires used in cardiovascular interventions may eliminate the need for separate IVUS catheters and expand the use of IVUS in a larger portion of the vasculature. High frequency capacitive micro machined ultrasonic transducer (CMUT) arrays should be integrated with interface electronics and placed on the guide wire for this purpose. Besides small size, this system-on-a-chip (SoC) front-end should connect to the back-end imaging system with a minimum number of wires to preserve the critical mechanical properties of the guide wire. We present a 40 MHz CMUT array interface SoC, which will eventually use only two wires for power delivery and transmits image data using a combination of analog-to-time conversion (ATC) and an impulse radio ultra-wideband (IR-UWB) wireless link. The proof-of-concept prototype ASIC consumes only 52.8 mW and occupies 4.07 [Formula: see text] in a 0.35- [Formula: see text] standard CMOS process. A rectifier and regulator power the rest of the SoC at 3.3 V from a 10 MHz power carrier that is supplied through a 2.4 m micro-coax cable with an overall efficiency of 49.1%. Echo signals from an 8-element CMUT array are amplified by a transimpedance amplifier (TIA) array and down-converted to baseband by quadrature sampling using a 40 MHz clock, derived from the power carrier. The ATC generates pulse-width-modulated (PWM) samples at 2 × 10 MS/s with 6 bit resolution, while the entire system achieved 5.1 ENOB. Preliminary images from the prototype system are presented, and alternative data transmission and possible future directions towards practical implementation are discussed.

  6. 77 FR 58424 - Drucker, Inc., DynaMotive Energy Systems Corp., and Gate to Wire Solutions, Inc., Order of...

    Science.gov (United States)

    2012-09-20

    ... From the Federal Register Online via the Government Publishing Office SECURITIES AND EXCHANGE COMMISSION Drucker, Inc., DynaMotive Energy Systems Corp., and Gate to Wire Solutions, Inc., Order of... current and accurate information concerning the securities of Gate to Wire Solutions, Inc. because it has...

  7. Force systems in the initial phase of orthodontic treatment -- a comparison of different leveling arch wires.

    Science.gov (United States)

    Fuck, Lars-Michael; Drescher, Dieter

    2006-01-01

    The determination of orthodontically-effective forces and moments places great demands on the technical equipment. Many patients report severe pain after fixed appliance insertion. Since it is assumed that pain from orthodontic appliances is associated with the force and moment levels applied to the teeth and since the occurrence of root resorption is a common therapeutic side effect, it would seem important to know the actual magnitudes of the components of the active orthodontic force systems. The aim of the present study was therefore to measure initial force systems produced by different leveling arch-wires in a complete multi-bracket appliance and to assess whether force and moment levels can be regarded as biologically acceptable or not. The actual bracket position in 42 patients was transferred onto a measurement model. Forces and moments produced by a super-elastic nickel-titanium (NiTi) archwire, a 6-strand stainless steel archwire, and a 7-strand super-elastic NiTi archwire were determined experimentally on different teeth. Average forces and moments produced by the super-elastic NiTi arch wires were found to be the highest. In spite if their larger diameter, the stranded arch wires' average force and moment levels were lower, especially that of the stranded super-elastic archwire. Nevertheless, maximum force levels sometimes exceeded recommended values in the literature and must be considered as too high. The measured arch wires' initial force systems differed significantly depending on the type of archwire and its material structure. Stranded arch wires produced lower force and moment levels, and we recommend their use in the initial phase of orthodontic treatment.

  8. Pulsed Heterodyne CO2 Laser/Scanner System. Volume 1. Assembly Report.

    Science.gov (United States)

    1983-06-01

    10.61i COZ lasinig wavelength. 4 I 0T 8I TEA LASER MODULATOR OIAG WIAG MOTOR FA 0gWA SUPPLY SLIP. TELE SCOPEI SUST. P.S. E BEAM SCANNER DRIVE moo...AFC TO)DT LASERL ELETOICS DET AFC DISCOS BAG PROCESO R Figure 4. Funetional Location of Numbers (SO) Optical Components V...partial reflector, 2 meters radius concave). For the most part these fragile 9 U TEA LASER MODULATOR WAGD -- WG. GAUGEK MOTOR PANQ 70SLIP. 0- G.0 3

  9. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  10. ORIS: the Oak Ridge Imaging System program listings. [Nuclear medicine imaging with rectilinear scanner and gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Bell, P. R.; Dougherty, J. M.

    1978-04-01

    The Oak Ridge Imaging System (ORIS) is a general purpose access, storage, processing and display system for nuclear medicine imaging with rectilinear scanner and gamma camera. This volume contains listings of the PDP-8/E version of ORIS Version 2. The system is designed to run under the Digital Equipment Corporation's OS/8 monitor in 16K or more words of core. System and image file mass storage is on RK8E disk; longer-time image file storage is provided on DECtape. Another version of this program exists for use with the RF08 disk, and a more limited version is for DECtape only. This latter version is intended for non-medical imaging.

  11. DC wiring system grounding and ground fault protection issues for central station photovoltaic power plants

    Science.gov (United States)

    Simburger, E. J.

    1983-01-01

    The DC wiring system for a photovoltaic power plant presents a number of unique challenges to be overcome by the plant designers. There are a number of different configurations that the grounding of the DC wiring system can take, and the choice will affect the number and type of protective devices required to ensure safety of personnel and protection of equipment. The major grounding and fault protection considerations that must be taken into account when selecting the basic overall circuit configuration are summarized. The inherent advantages and disadvantages of each type of circuit grounding (resistance or solid) along with the personnel safety and equipment protection issues for each of these grounding methods are presented.

  12. A Predictive Velocity Observer in Wire Bonder’s Control System

    Directory of Open Access Journals (Sweden)

    Lei Zhou

    2014-01-01

    Full Text Available Wire bonder is a typical high speed machine. The motion speed of XY-stage is the key factor of bonding efficiency. However, phase lag elements in the servo system limit the bandwidth and slow down the system’s response. A predictive velocity observer is proposed to compensate for those phase lags. Then, the velocity loop controller can be designed as for a servo system which does not have those phase lags. Loop gains are enlarged and bandwidth is enlarged correspondingly. Then, the motion speed is improved and settling time is decreased. Experiment results verify that the predictive velocity observer provided a significant phase lead and the performance of wire bonder is improved.

  13. Survivability design guidelines for Fly-By-Wire Flight Control Systems development.

    OpenAIRE

    Hogan, Daniel Timothy.

    1983-01-01

    Approved for public release; distribution is unlimited Survivability of military combat aircraft has received increased emphasis by the U.S. Armed Services in recent years. The primary objective of the U.S. Military Survivability Policy is to ensure that effective survivability enhancement features are incorporated in current and all future U.S. combat aircraft. Technology advances in Fly-By-Wire Flight Control Systems have significantly enhanced the performance capabilities...

  14. Handbook of sensor networks compact wireless and wired sensing systems

    CERN Document Server

    Ilyas, Mohammad

    2004-01-01

    INTRODUCTION Opportunities and Challenges in Wireless Sensor Networks, M. Haenggi, Next Generation Technologies to Enable Sensor Networks, J. I.  Goodman, A. I. Reuther, and D. R. Martinez Sensor Networks Management, L. B. Ruiz, J. M. Nogueira, and A. A. F. Loureiro Models for Programmability in Sensor Networks, A. Boulis Miniaturizing Sensor Networks with MEMS, Brett Warneke A Taxonomy of Routing Techniques in Wireless Sensor Networks, J. N. Al-Karaki and A. E. Kamal Artificial Perceptual Systems, A. Loutfi, M. Lindquist, and P. Wide APPLICATIONS Sensor Network Architecture and Appl

  15. Release measurement of great amount of waste. Conveyor belt versus wire mesh pallet systems

    International Nuclear Information System (INIS)

    Sokcic-Kostic, Marina; Schultheis, Roland; Langer, Felix

    2014-01-01

    Great amount of waste has to be measured for release during the decommissioning and rebuilding of nuclear facilities and installation. Since the enclosed storage or decontamination is very expensive it is advisable for economic reasons to separate contaminated material. The necessary measurement is however a time and cost intensive work which has carefully provided. There are two general methods to perform this task: one is a continuously running system on the basis of a conveyor belt system. The other approach is a discontinuously running system using wire mesh pallets. With the knowledge from existing installations this article will discuss the pro's and contra's and show the limits of the systems.

  16. The influence of bracket design on frictional losses in the bracket/arch wire system.

    Science.gov (United States)

    Schumacher, H A; Bourauel, C; Drescher, D

    1999-01-01

    In arch guided tooth movement, the essential role played by bracket configuration with respect to sliding friction has been recognized by the manufacturers, a fact which has had an increasing impact on the design and marketing of new bracket models in recent years. The aim of the present in-vitro study was to investigate the influence of different bracket designs on sliding mechanics. Five differently shaped stainless steel brackets (Discovery: Dentaurum, Damon SL: A-Company, Synergy: Rocky Mountain Orthodontics, Viazis bracket and Omni Arch appliance: GAC) were compared in the 0.022"-slot system. The Orthodontic Measurement and Simulation System (OMSS) was used to quantify the difference between applied force (NiTi coil spring, 1.0 N) and orthodontically effective force and to determine leveling losses occurring during the sliding process in arch guided tooth movement. Simulated canine retraction was performed using continuous arch wires with the dimensions 0.019" x 0.025" (Standard Steel, Unitek) and 0.020" x 0.020" (Ideal Gold, GAC). Comparison of the brackets revealed friction-induced losses ranging from 20 to 70%, with clear-cut advantages resulting from the newly developed bracket types. However, an increased tendency towards leveling losses in terms of distal rotation (maximum 15 degrees) or buccal root torque (maximum 20 degrees) was recorded, especially with those brackets giving the arch wire increased mobility due to their shaping or lack of ligature wire.

  17. Design and test experience with a triply redundant digital fly-by-wire control system

    Science.gov (United States)

    Szalai, K. J.; Felleman, P. G.; Gera, J.; Glover, R. D.

    1976-01-01

    A triplex digital fly-by-wire flight control system was developed and then installed in a NASA F-8C aircraft to provide fail-operative, full authority control. Hardware and software redundancy management techniques were designed to detect and identify failures in the system. Control functions typical of those projected for future actively controlled vehicles were implemented. This paper describes the principal design features of the system, the implementation of computer, sensor, and actuator redundancy management, and the ground test results. An automated test program to verify sensor redundancy management software is also described.

  18. Error-tolerant pedal for a brake-by-wire system; Fehlertolerante Pedaleinheit fuer ein elektromechanisches Bremssystem (Brake-by-Wire)

    Energy Technology Data Exchange (ETDEWEB)

    Stoelzl, S.

    2000-07-01

    The author describes the development of an error-tolerant brake-by-wire system with pedal consolidation, including the development of a monitoring and safety concept. [German] Die zunehmende Entwicklung aktiver Fahrerassistenzsysteme im Automobilbereich (z.B. ABS, ESP) zur Erhoehung der Fahrsicherheit erfordert ein staendig wachsendes Funktionspotential. Die Bremsanlagen werden dadurch immer komplexer. Parallel steigen die Anforderungen an den Bremspedalkomfort. Einen Ausweg aus dieser Problematik verspricht die Elektromechanische Bremsanlage (EMB) mit rueckwirkungsfreier Entkopplung des Fahrers von den Radbremsen (Brake-by-Wire). Das Bremskommando des Fahrers wird bei Betaetigung des Bremspedals rein sensorisch erfasst. Da es keine mechanische Rueckfallebene mehr gibt, muessen Fehler der Pedaleinheit erkannt und toleriert werden. Neu an dieser Arbeit ist die Entwicklung der fehlertoleranten elektromechanischen Pedaleinheit der EMB mit Pedalsensorkonsolidierung und Erstellung des dazu notwendigen Sicherheits- und Ueberwachungskonzepts. (orig.)

  19. Fallback level concepts for conventional and by-wire automotive brake systems

    International Nuclear Information System (INIS)

    Retzer, H; Mishra, R; Ball, A; Schmidt, K

    2012-01-01

    Brake-by-wire represents the replacement of traditional brake components such as pumps, hoses, fluids, brake boosters, and master cylinders by electronic sensors and actuators. The different design of these brake concepts poses new challenges for the automotive industry with regard to availability and fallback levels in comparison to standard conventional brake systems. This contribution focuses on the development of appropriate fallback level concepts. Hardware-in-the-loop (HIL) techniques and field trials will be used to investigate the performance and the usability of such systems.

  20. Basic Wiring.

    Science.gov (United States)

    Kaltwasser, Stan; And Others

    This module is the first in a series of three wiring publications; it serves as the foundation for students enrolled in a wiring program. It is a prerequisite to either "Residential Wiring" or "Commercial and Industrial Wiring." The module contains 16 instructional units that cover the following topics: occupational…

  1. Description and Flight Test Results of the NASA F-8 Digital Fly-by-Wire Control System

    Science.gov (United States)

    1975-01-01

    A NASA program to develop digital fly-by-wire (DFBW) technology for aircraft applications is discussed. Phase I of the program demonstrated the feasibility of using a digital fly-by-wire system for aircraft control through developing and flight testing a single channel system, which used Apollo hardware, in an F-8C airplane. The objective of Phase II of the program is to establish a technology base for designing practical DFBW systems. It will involve developing and flight testing a triplex digital fly-by-wire system using state-of-the-art airborne computers, system hardware, software, and redundancy concepts. The papers included in this report describe the Phase I system and its development and present results from the flight program. Man-rated flight software and the effects of lightning on digital flight control systems are also discussed.

  2. Simulations of quantum transport in nanoscale systems: application to atomic gold and silver wires

    DEFF Research Database (Denmark)

    Mozos, J.L.; Ordejon, P.; Brandbyge, Mads

    2002-01-01

    . The potential drop profile and induced electronic current (and therefore the conductance) are obtained from first principles. The method takes into account the atomic structure of both the nanoscale structure and the semi-infinite electrodes through which the potential is applied. Non-equilibrium Green......'s function techniques are used to calculate the quantum conductance. Here we apply the method to the study of the electronic transport in wires of gold and silver with atomic thickness. We show the results of our calculations, and compare with some of the abundant experimental data on these systems....

  3. Experience with a fuel rod enrichment scanner

    International Nuclear Information System (INIS)

    Kubik, R.N.; Pettus, W.G.

    1975-01-01

    This enrichment scanner views all fuel rods produced at B and W's Commercial Nuclear Fuel Plant. The scanner design is derived from the PAPAS System reported by R. A. Forster, H. D. Menlove, and their associates at Los Alamos. The spatial resolution of the system and smoothing of the data are discussed in detail. The cost-effectiveness of multi-detector versus single detector scanners of this general design is also discussed

  4. The effect of clamping a tensioned wire: implications for the Ilizarov external fixation system.

    Science.gov (United States)

    Watson, M A; Mathias, K J; Maffulli, N; Hukins, D W L

    2003-01-01

    This study demonstrates that clamping a tensioned wire can cause a reduction in wire tension. Tension (about 1275 N) was applied to a wire that was subsequently clamped, using cannulated bolts, to the steel half-ring of an Ilizarov external fixator. The tension in the wire was monitored before, during and after clamping. The apparatus was disassembled and the deformations in the wire caused by the clamps were measured. This experiment was repeated 15 times. When the wire was clamped to the frame, the wire tension was reduced by 22 +/- 7 per cent (mean +/- standard deviation, SD). The drop in wire tension was linearly correlated (r = 0.96; p toothpaste from a tube) and so reduce its tension during fixator assembly. To assess the magnitude of this effect in the clinical situation, the FE model analysis was repeated to replicate clamping a 1.8-mm-diameter wire to a 180-mm-diameter steel Ilizarov ring component. The analysis showed that for these conditions the tension reduced by 8-29 per cent. The results of this study highlight a general engineering problem: how can a tensioned wire be secured to a structure without an appreciable loss of tension? If the performance of the structure depends on the wire tension, this performance will change when the wire is secured.

  5. Scanner Development

    Science.gov (United States)

    1978-07-01

    Griot , with this lens (No. 01-LAO-255), spot growth ’is less than 8 percent over a 50 image field from the center to the edge, which puts this...minimum length quality lens which satisfies the system requirments. Of lenses surveyed from Rolyn Optics, Melles Griot , Klirngler Scientific, and a number...of other minor 44 suppliers, the smallest EFL available cwe in the form of computer-optimized achromatic 80 mm focal length doublets from Melles Griot

  6. Untangling the wiring of the Drosophila visual system: developmental principles and molecular strategies.

    Science.gov (United States)

    Plazaola-Sasieta, Haritz; Fernández-Pineda, Alejandra; Zhu, Qi; Morey, Marta

    2017-12-01

    The assembly of neural circuits relies on the accurate establishment of connections between synaptic partners. Precise wiring results from responses that neurons elicit to environmental cues and cell-cell contact events during development. A common design principle in both invertebrate and vertebrate adult nervous systems is the orderly array of columnar and layered synaptic units of certain neuropils. This similarity is particularly striking in the visual system, both at the structural and cell-type levels. Given the powerful genetic approaches and tools available in Drosophila, the fly visual system has been extensively used to probe how specific wiring patterns are achieved during development. In this review, we cover the developmental principles and molecular strategies that govern the assembly of columnar units (lamina cartridges and medulla columns), the formation of layers, afferent specific layer selection, and synaptogenesis in Drosophila. The mechanisms include: sequential developmental steps that ensure coordinated assembly of synaptic partners; anterograde and autocrine signaling; interactions between cell-surface molecules, or secreted molecules and their receptors that take place among neurons; and glia signaling to neurons.

  7. 46 CFR 111.60-11 - Wire.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be...

  8. Design and Experimental Research of New Type Brake by Wire System Based on Giant-magnetostrictive Material

    Directory of Open Access Journals (Sweden)

    Changbao CHU

    2014-04-01

    Full Text Available In this paper, H type brake by wire system based on giant-magnetostrictive material is designed from two aspects of hardware and software. System principle prototype is manufactured. Hardware circuit mainly includes the Sepic circuit, current detection circuit, over current protection circuit, PWM driver protection circuit. Circuit parameters can be obtained through by theoretical calculation. Pedal sensor signal is taken as main control variable, look-up table method is used for brake by wire system. The experimental results show that the system can meet the braking requirements. It proves the feasibility of the scheme.

  9. Release measurement of great amount of waste. Conveyor belt versus wire mesh pallet systems

    Energy Technology Data Exchange (ETDEWEB)

    Sokcic-Kostic, Marina; Schultheis, Roland; Langer, Felix [NUKEM Technologies Engineering Services GmbH, Alzenau (Germany)

    2014-08-15

    Great amount of waste has to be measured for release during the decommissioning and rebuilding of nuclear facilities and installation. Since the enclosed storage or decontamination is very expensive it is advisable for economic reasons to separate contaminated material. The necessary measurement is however a time and cost intensive work which has carefully provided. There are two general methods to perform this task: one is a continuously running system on the basis of a conveyor belt system. The other approach is a discontinuously running system using wire mesh pallets. With the knowledge from existing installations this article will discuss the pro's and contra's and show the limits of the systems.

  10. Parallel power electronics filters in three-phase four-wire systems principle, control and design

    CERN Document Server

    Wong, Man-Chung; Lam, Chi-Seng

    2016-01-01

    This book describes parallel power electronic filters for 3-phase 4-wire systems, focusing on the control, design and system operation. It presents the basics of power-electronics techniques applied in power systems as well as the advanced techniques in controlling, implementing and designing parallel power electronics converters. The power-quality compensation has been achieved using active filters and hybrid filters, and circuit models, control principles and operational practice problems have been verified by principle study, simulation and experimental results. The state-of-the-art research findings were mainly developed by a team at the University of Macau. Offering background information and related novel techniques, this book is a valuable resource for electrical engineers and researchers wanting to work on energy saving using power-quality compensators or renewable energy power electronics systems. .

  11. Experimental MRI-SPECT insert system with Hybrid Semiconductor detectors Timepix for MR animal scanner Bruker 47/20

    Science.gov (United States)

    Zajicek, J.; Burian, M.; Soukup, P.; Novak, V.; Macko, M.; Jakubek, J.

    2017-01-01

    Multimodal medical imaging based on Magnetic Resonance is mainly combinated with one of the scintigraphic method like PET or SPECT. These methods provide functional information whereas magnetic resonance imaging provides high spatial resolution of anatomical information or complementary functional information. Fusion of imaging modalities allows researchers to obtain complimentary information in a single measurement. The combination of MRI with SPECT is still relatively new and challenging in many ways. The main complication of using SPECT in MRI systems is the presence of a high magnetic field therefore (ferro)magnetic materials have to be eliminated. Furthermore the application of radiofrequency fields within the MR gantry does not allow for the use of conductive structures such as the common heavy metal collimators. This work presents design and construction of an experimental MRI-SPECT insert system and its initial tests. This unique insert system consists of an MR-compatible SPECT setup with CdTe pixelated sensors Timepix tungsten collimators and a radiofrequency coil. Measurements were performed on a gelatine and tissue phantom with an embedded radioisotopic source (57Co 122 keV γ ray) inside the RF coil by the Bruker BioSpec 47/20 (4.7 T) MR animal scanner. The project was performed in the framework of the Medipix Collaboration.

  12. Geometric calibration between PET scanner and structured light scanner

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Olesen, Oline Vinter; Paulsen, Rasmus Reinhold

    2011-01-01

    Head movements degrade the image quality of high resolution Positron Emission Tomography (PET) brain studies through blurring and artifacts. Manny image reconstruction methods allows for motion correction if the head position is tracked continuously during the study. Our method for motion tracking...... is a structured light scanner placed just above the patient tunnel on the High Resolution Research Tomograph (HRRT, Siemens). It continuously registers point clouds of a part of the patient's face. The relative motion is estimated as the rigid transformation between frames. A geometric calibration between...... the HRRT scanner and the tracking system is needed in order to reposition the PET listmode data or image frames in the HRRT scanner coordinate system. This paper presents a method where obtained transmission scan data is segmented in order to create a point cloud of the patient's head. The point clouds...

  13. Multifunctional cube-like system for biomedical applications featuring 3D printing by dual deposition, scanner, and UV engraving

    Science.gov (United States)

    Guzmán-González, J. V.; Saldaña-Martínez, M. I.; Barajas-González, O. G.; Guzmán-Ramos, V.; García-Garza, A. K.; Franco-Herrada, M. G.; Selvas Aguilar, R. J.; García-Ramírez, M. A.

    2017-02-01

    In this paper, a cubic-like structure is proposed to scan and print tools used as medical equipment at low cost for developing countries. The structure features a 3-axis frame plane that uses high-precision step motors. An actuator drives the "x and y" axis through serrated bands with 2 mm pitch. Those give an accuracy of 2.5 microns tops. The z-axe is driven by and inductive sensor that allows us to keep the focus to the printing bed as well as to search for non-smooth areas to correct it and deliver an homogeneous impression. The 3D scanner as well as the entire gears are placed underneath in order to save space. As extrude tip, we are using a 445 nm UV laser with 2000 mW of power. The laser system is able to perform several functions such as crystallizing, engraving or cut though a set of mirror arrays. Crystallization occurs when the laser is guided towards the base. This process allows us to direct it towards the polymer injector and as a result, it crystalizes on the spot. Another feature that this system is the engraving process that occurs while the base moves. The movement allows the beam to pass freely towards the base and perform the engraving process.

  14. Design and development experience with a digital fly-by-wire control system in an F-8C airplane

    Science.gov (United States)

    Deets, D. A.

    1976-01-01

    To assess the feasibility of a digital fly by wire system, the mechanical flight control system of an F-8C airplane was replaced with a digital primary system and an analog backup system. The Apollo computer was used as the heart of the primary system. This paper discusses the experience gained during the design and development of the system and relates it to active control systems that are anticipated for future civil transport applications.

  15. Novel Hemispherical Scanner for a Coherent Fiber LIDAR System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — LIDAR (LIght Detection And Ranging) systems have proven their value in the remote measurement of spatially resolved atmospheric wind velocities in a number of...

  16. Novel Hemispherical Scanner for a Coherent Fiber LIDAR System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — SibellOptics proposes to develop an eye-safe, long-range, compact, versatile, all-fiber wind LIDAR system for atmospheric wind velocity measurement applications that...

  17. The effect of electrostatic and gravity force on offset wire inside tube

    Science.gov (United States)

    Oh, S. H.; Hazineh, D.; Wang, C.

    2018-04-01

    In a straw-tube detector, a wire that is offset with respect to the tube axis experiences a Coulomb force when high voltage is applied between the anode wire and the tube. This force results in a shifting of the wire and straw, in addition to the gravitational sag, and is a function of the tube and wire radius, initial offset, high voltage, tension and length. The presence of such effects is well known, but the precise magnitude of the shift for the anode wires under conditions of detector operation have not been previously documented with measurable confidence. In this work, we provide the first systematic measurements for the wire shift in straw-tube detectors due to gravity and the electrostatic force using an x-ray scanner developed for the Mu2e experiment. The data are compared to the solutions of the differential equations governing the system, and we find a good match between the two. The solutions can predict the final wire and straw positions from the initial positions measured without the high voltage, and the final wire and straw positions can then be used as an input to the track reconstruction software to improve the track position resolution.

  18. Optical scanner system for high resolution measurement of lubricant distributions on metal strips based on laser induced fluorescence

    Science.gov (United States)

    Holz, Philipp; Lutz, Christian; Brandenburg, Albrecht

    2017-06-01

    We present a new optical setup, which uses scanning mirrors in combination with laser induced fluorescence to monitor the spatial distribution of lubricant on metal sheets. Current trends in metal processing industry require forming procedures with increasing deformations. Thus a welldefined amount of lubricant is necessary to prevent the material from rupture, to reduce the wearing of the manufacturing tool as well as to prevent problems in post-deforming procedures. Therefore spatial resolved analysis of the thickness of lubricant layers is required. Current systems capture the lubricant distribution by moving sensor heads over the object along a linear axis. However the spatial resolution of these systems is insufficient at high strip speeds, e.g. at press plants. The presented technology uses fast rotating scanner mirrors to deflect a laser beam on the surface. This 405 nm laser light excites the autofluorescence of the investigated lubricants. A coaxial optic collects the fluorescence signal which is then spectrally filtered and recorded using a photomultiplier. From the acquired signal a two dimensional image is reconstructed in real time. This paper presents the sensor setup as well as its characterization. For the calibration of the system reference targets were prepared using an ink jet printer. The presented technology for the first time allows a spatial resolution in the millimetre range at production speed. The presented test system analyses an area of 300 x 300 mm² at a spatial resolution of 1.1 mm in less than 20 seconds. Despite this high speed of the measurement the limit of detection of the system described in this paper is better than 0.05 g/m² for the certified lubricant BAM K-009.

  19. Comparison of the initial orthodontic force systems produced by a new lingual bracket system and a straight-wire appliance.

    Science.gov (United States)

    Fuck, Lars-Michael; Wiechmann, Dirk; Drescher, Dieter

    2005-09-01

    Over the last few years, lingual appliances have become an established orthodontic treatment technique. Many studies have concentrated on various esthetic aspects, on laboratory and clinical procedures, and on patient comfort and compliance. The orthodontic force systems of these appliances, however, have not yet been investigated. The aim of this study was thus to determine the forces and moments produced by a new lingual bracket system during the leveling phase of orthodontic treatment and to compare those with the corresponding force system of a labial straight-wire appliance. The intra-oral situation of ten patients undergoing orthodontic treatment was replicated in measurement casts fitted with lingual and labial brackets. Special care was taken to precisely reproduce each patient's interbracket geometry. We measured each tooth's force systems as generated by a leveling arch inserted into the lingual and labial brackets. The resulting force systems of both appliances were found to be quite similar with regard to the magnitude of most force and moment components. Only the first molars were subjected to considerably greater single forces with the lingual appliance. Tipping moments were found to be significantly smaller with the lingual technique, whereas the rotational moments were significantly smaller with the labial appliance. All in all we noted significant differences between the two techniques only in certain areas which upon closer examination were distributed over only a few tooth types. The initial force systems produced by the new lingual bracket system proved to be comparable with those delivered by a conventional straight-wire appliance. The actual levels of forces and moments, however, were found in certain cases to be too heavy with both techniques. We therefore recommend the development of leveling wires producing considerably lighter forces and moments.

  20. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  1. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  2. Implementation of a versatile research data acquisition system using a commercially available medical ultrasound scanner

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Nikolov, Svetoslav Ivanov; Pedersen, Mads Møller

    2012-01-01

    to give researchers and clinicians the ability to utilize third-party software for data analysis and flexible manipulation of control parameters. Because of the advantages of speed of acquisition and clinical benefit, research projects have successfully used the system to test and implement...

  3. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  4. ACCURACY COMPARISON OF DIGITAL SURFACE MODELS CREATED BY UNMANNED AERIAL SYSTEMS IMAGERY AND TERRESTRIAL LASER SCANNER

    Directory of Open Access Journals (Sweden)

    M. Naumann

    2013-08-01

    Full Text Available The main focus of the paper is a comparative study in which we have investigated, whether automatically generated digital surface models (DSM obtained from unmanned aerial systems (UAS imagery are comparable with DSM obtained from terrestrial laser scanning (TLS. The research is conducted at a pilot dike for coastal engineering. The effort and the achievable accuracy of both DSMs are compared. The error budgets of these two methods are investigated and the models obtained in each case compared against each other.

  5. Gamma ray scanner systems for nondestructive assay of heterogeneous waste barrels

    International Nuclear Information System (INIS)

    Martz, H.E.; Decman, B.J.; Roberson, G.P.; Levai, F.

    1997-01-01

    Traditional gamma safeguards measurements have usually been performed using a segmented gamma scanning (SGS) system. The accuracy of this technique relies on the assumption that the sample matrix and the activity are both uniform for a segment. Waste barrels are often highly heterogeneous, span a wide range of composition and matrix type. The primary sources of error are all directly or indirectly related to a non-uniform measurement response associated with unknown radioactive source spatial distribution and heterogeneity of the matrix. These errors can be significantly reduced by some imaging techniques that measure exact spatial locations of sources and attenuation maps. In this paper we describe a joint R ampersand D effort between the Lawrence Livermore National Laboratory (LLNL) and the Institute of Nuclear Techniques (INT) of the Technical University, Budapest, to compare results obtained by two different gamma-ray nondestructive assay (NDA) systems used for imaging waste barrels. The basic principles are the same, but the approaches are different. Key factors to judge the adequacy of a method are the detection limit and the accuracy. Test drums representing waste to be measured are used to determine basic parameters of these techniques

  6. Proportional wire chamber system for beam definition in precision total cross section measurements

    International Nuclear Information System (INIS)

    Carroll, A.S.; Chiang, I.H.; Kycia, T.F.

    1978-03-01

    A PWC system was developed and extensively used in precision measurements of total cross sections at low momenta (0.4 to 1.1 GeV/c) and at high momenta (23 to 370 GeV/c). This ''electronic collimator'' operated simultaneously in a fast (250 nsec) decision making mode, and a slower (0.5 msec) readout mode. The decision making mode utilized adjustable hard-wired logic to define acceptable incident beam trajectories and reject multiple beam tracks. A sample of the events were read into an on-line computer for beam tuning, for chamber diagnostics, and for study of the effect of small angle scattering to verify the total cross section extrapolation procedure

  7. Alpha–beta monitoring system based on pair of simultaneous Multi-Wire Proportional Counters

    Energy Technology Data Exchange (ETDEWEB)

    Wengrowicz, U.; Amidan, D. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel); NRC-Negev, P.O. Box 9001, Beer-Sheva 84190 (Israel); Orion, I. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel)

    2016-08-11

    A new approach for a simultaneous alpha–beta Multi-wire Proportional Counter (MWPC) is presented. The popular approach for alpha–beta monitoring systems consists of a large area MWPC using noble gas flow such as Argon Methane. This method of measurement is effective but requires large-scale and expensive maintenance due to the needs of gas flow control and periodic replacements. In this work, a pair of simultaneous MWPCs for alpha–beta measuring is presented. The developed detector consists of a sealed gas MWPC sensor for beta particles, behind a free air alpha sensor. This approach allows effective simultaneous detection and discrimination of both alpha and beta radiation without the maintenance cost noble gas flow required for unsealed detectors.

  8. Ray-tracing study on the post-scanner variable beam expansion optics in a two-photon microscopy system

    Science.gov (United States)

    Kim, Do-Hyun; Welle, Cristin; Krauthamer, Victor

    2012-03-01

    Due to the low signal levels typical of two-photon microscopy (TPM) in biological samples, optical design optimization is critical. One of the most important factors is overfilling of the back aperture of the objective lens. A variable beam expander is commonly placed before the scanning mirrors to achieve this goal, however, this may cause degradation of image quality due to increased dispersion. Additionally, scanning mirror size restricts the degree of expansion, which often prevents the overfilling of objective lens back aperture. We investigated the implementation of variable beam expansion optics after the scanning mirrors. Ray-tracing analyses confirmed that the post-scanner beam expansion has two key advantages over the conventional pre-scanner beam expansion approach: decreasing the number of optical elements reduces pulse dispersion and reducing the size of the scanning mirror enables faster scanning. Resolution and aberration of a TPM with post-scanner beam expansion optics were analysed.

  9. A hybrid DGTD scheme for transient analysis of electromagnetic field interactions on microwave systems loaded with thin wires

    KAUST Repository

    Li, Ping

    2015-10-15

    Use of the discontinuous Galerkin time-domain (DGTD) method for analyzing electromagnetic field interactions on microwave structures loaded with thin wires has been very limited despite its well-known advantages. Direct application of the three dimensional (3D) DGTD method to such structures calls for very fine volumetric discretizations in the proximity of the thin wires. In this work, to avoid this possible source of computational inefficiency, electromagnetic field interactions on thin wires and the rest of the structures are modeled separately using the modified telegrapher and Maxwell equations, respectively. Then, 1D and 3D DGTD methods are used to discretize them. The coupling between the two resulting matrix systems is realized by introducing equivalent source terms in each equation set. A weighted electric field obtained from the 3D discretization around the wire is introduced as a voltage source in the telegrapher equations. A volume current density obtained from the 1D discretization on the wire is introduced as a current source in the Ampere law equation. © 2015 IEEE.

  10. 3D whole body scanners revisited

    NARCIS (Netherlands)

    Daanen, H.A.M.; Haar, F.B. ter

    2013-01-01

    An overview of whole body scanners in 1998 (H.A.M. Daanen, G.J. Van De Water. Whole body scanners, Displays 19 (1998) 111-120) shortly after they emerged to the market revealed that the systems were bulky, slow, expensive and low in resolution. This update shows that new developments in sensing and

  11. Design of Two Feeder Three Phase Four Wire Distribution System Utilizing Multi Converter UPQC with Fuzzy Logic Controller

    Directory of Open Access Journals (Sweden)

    Chandra Babu Paduchuri

    2014-01-01

    Full Text Available This paper proposes the instantaneous p-q theory based fuzzy logic controller (FLC for multi converter unified power quality conditioner (MC-UPQC to mitigate power quality issues in two feeders three-phase four-wire distribution systems. The proposed system is extended system of the existing one feeder three-phase four-wire distribution system, which is operated with UPQC. This system is employed with three voltage source converters, which are connected commonly to two feeder distribution systems. The performance of this proposed system used to compensate voltage sag, neutral current mitigation and compensation of voltage and current harmonics under linear and nonlinear load conditions. The neutral current flowing in series transformers is zero in the implementation of the proposed system. The simulation performance analysis is carried out using MATLAB.

  12. Creation of subsonic macro-and microjets facilities and automated measuring system (AMS-2) for the spatial - temporal hot - wire anemometric visualization of jet flow field

    Science.gov (United States)

    Sorokin, A. M.; Grek, G. R.; Gilev, V. M.; Zverkov, I. D.

    2017-10-01

    Macro-and microjets facilities for generation of the round and plane subsonic jets are designed and fabricated. Automated measuring system (AMS - 2) for the spatial - temporal hot - wire anemometric visualization of jet flow field is designed and fabricated. Coordinate device and unit of the measurement, collecting, storage and processing of hot - wire anemometric information were integrated in the AMS. Coordinate device is intended for precision movement of the hot - wire probe in jet flow field according to the computer program. At the same time accuracy of the hot - wire probe movement is 5 microns on all three coordinates (x, y, z). Unit of measurement, collecting, storage and processing of hot - wire anemometric information is intended for the hot - wire anemometric measurement of the jet flow field parameters (registration of the mean - U and fluctuation - u' characteristics of jet flow velocity), their accumulation and preservation in the computer memory, and also carries out their processing according to certain programms.

  13. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  14. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  15. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  16. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  17. Transient fault tolerant control for vehicle brake-by-wire systems

    International Nuclear Information System (INIS)

    Huang, Shuang; Zhou, Chunjie; Yang, Lili; Qin, Yuanqing; Huang, Xiongfeng; Hu, Bowen

    2016-01-01

    Brake-by-wire (BBW) systems that have no mechanical linkage between the brake pedal and the brake mechanism are expected to improve vehicle safety through better braking capability. However, transient faults in BBW systems can cause dangerous driving situations. Most existing research in this area focuses on the brake control mechanism, but very few studies try to solve the problem associated with transient fault propagation and evolution in the brake control system hierarchy. In this paper, a hierarchical transient fault tolerant scheme with embedded intelligence and resilient coordination for BBW system is proposed based on the analysis of transient fault propagation characteristics. In this scheme, most transient faults are tackled rapidly by a signature-based detection method at the node level, and the remaining transient faults, which cannot be detected directly at the node level and could degrade the system performance through fault propagation and evolution, are detected and recovered through function and structure models at the system level. To jointly accommodate these BBW transient faults at the system level, a sliding mode control algorithm and a task reallocation strategy are designed. A simulation platform based on Architecture Analysis and Design Language (AADL) is established to evaluate the task reallocation strategy, and a hardware-in-the-loop simulation is carried out to validate the proposed scheme systematically. Experimental results show the effectiveness of this new approach to BBW systems. - Highlights: • We propose a hierarchical transient fault tolerant scheme for BBW systems. • A sliding mode algorithm and a task strategy are designed to tackle transient fault. • The effectiveness of the scheme is verified in both simulation and HIL environments.

  18. Analysis in vitro of direct bonding system with cyanoacrylate ester and orthodontic wires.

    Science.gov (United States)

    Manfrin, Thais Mara; Poi, Wilson Roberto; de Mendonça, Marcos Rogério; Cardoso, Leandro Carvalho; Massa Sundefeld, Maria Lúcia Marçal; Sonoda, Celso Koogi; Panzarini, Sônia Regina

    2009-04-01

    The aim of this study was to evaluate the tensile strength of orthodontic wires bonded onto the enamel with cyanoacrylate ester. To obtain the specimens, 120 human premolars (extracted for orthodontic or periodontal reasons) were included in acrylic blocks of rapid polymerization with three teeth each. Four groups were formed with ten specimens each. In the specimens, a dental splint model was made with cyanoacrylate ester and round stainless steel wire. In groups I, II and III, cyanoacrylate ester was used with round steel wires, with variation in diameter: 0.014 inches; 0.016 inches and 0.018 inches, respectively. In group IV, round steel wire 0.018 inches was used with photo polymerizing resin composite with previous acid etching. The adhesive force of the materials was measured in two points under the action of the tensiometer (ETM-USA). The number of loose wires was counted along with those that remained fixed according to the different levels of force applied because of the direction of the tensile force (vertical or horizontal) and the diameter of the wire used. The data obtained were first submitted to a descriptive analysis and then submitted to a statistical analysis (Friedman's Test and Dunn's Test of Multiple Comparison - Epi-info 3.2). Within the limitations of the experimental conditions presented, the cyanoacrylate ester or 'Super Bonder' maintained bonded to enamel and steel wires (0.016 and 0.018 inches) during the tensile strength tests under different levels of applied forces.

  19. A new wire chamber front-end system, based on the ASD-8 B chip

    Energy Technology Data Exchange (ETDEWEB)

    Kruesemann, B.A.M. E-mail: kruesemann@kvi.nl; Bassini, R.; Ellinghaus, F.; Frekers, D.; Hagemann, M.; Hannen, V.M.; Heynitz, H. von; Heyse, J.; Rakers, S.; Sohlbach, H.; Woertche, H.J

    1999-07-11

    The Focal-Plane Polarimeter (FPP) for the Big-Bite Spectrometer van den Berg (Nucl. Instr. and Meth. B 99 (1995) 637ff) at the KVI requires the read-out of four large-area MWPCs and two VDCs with 3872 wires in total. The EUROSUPERNOVA collaboration (SNOVA) developed a digital 16 channel preamplifier front-end board, housing two amplifier-shaper-discriminatorchips ASD-8 B. The main features of this board are a fast single-wire readout, a high integration density, a low power consumption and compatibility to common instrumentation standards. The board represents the first successfully running application of the ASD-8 for wire chamber readout. (author)

  20. A new wire chamber front-end system, based on the ASD-8 B chip

    CERN Document Server

    Kruesemann, B A M; Ellinghaus, F; Frekers, D; Hagemann, M; Hannen, V M; Heynitz, H V; Heyse, J; Rakers, S; Sohlbach, H; Wörtche, H J

    1999-01-01

    The Focal-Plane Polarimeter (FPP) for the Big-Bite Spectrometer van den Berg (Nucl. Instr. and Meth. B 99 (1995) 637ff) at the KVI requires the read-out of four large-area MWPCs and two VDCs with 3872 wires in total. The EUROSUPERNOVA collaboration (SNOVA) developed a digital 16 channel preamplifier front-end board, housing two amplifier-shaper-discriminatorchips ASD-8 B. The main features of this board are a fast single-wire readout, a high integration density, a low power consumption and compatibility to common instrumentation standards. The board represents the first successfully running application of the ASD-8 for wire chamber readout. (author)

  1. Architectural design and reliability analysis of a fail-operational brake-by-wire system from ISO 26262 perspectives

    International Nuclear Information System (INIS)

    Sinha, Purnendu

    2011-01-01

    Next generation drive-by-wire automotive systems enabling autonomous driving will build on the fail-operational capabilities of electronics, control and software (ECS) architectural solutions. Developing such architectural designs that would meet dependability requirements and satisfy other system constraints is a challenging task and will possibly lead to a paradigm shift in automotive ECS architecture design and development activities. This aspect is becoming quite relevant while designing battery-driven electric vehicles with integrated in-wheel drive-train and chassis subsystems. In such highly integrated dependable systems, many of the primary features and functions are attributed to the highest safety critical ratings. Brake-by-wire is one such system that interfaces with active safety features built into an automobile, and which in turn is expected to provide fail-operational capabilities. In this paper, building up on the basic concepts of fail-silent and fail-operational systems design we propose a system-architecture for a brake-by-wire system with fail-operational capabilities. The design choices are supported with proper rationale and design trade-offs. Safety and reliability analysis of the proposed system architecture is performed as per the ISO 26262 standard for functional safety of electrical/electronic systems in road vehicles.

  2. FINE-FILAMENT MAGNESIUM DIBORIDE SUPERCONDUCTOR WIRE FOR TURBOELECTRIC PROPULSION SYSTEMS, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The availability of low AC loss magnesium diboride (MgB2) superconducting wires enables much lighter weight superconducting stator coils than with any other metal or...

  3. Lightweight Metal Rubber Wire and Cable for Space Power Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this NASA STTR program is to produce ultra-lightweight electrical wire and cable harnesses to reduce the liftoff weight of future space flight...

  4. Six-state, three-level, six-fold ferromagnetic wire system

    International Nuclear Information System (INIS)

    Blachowicz, T.; Ehrmann, A.

    2013-01-01

    Six stable states at remanence were identified in iron wire samples of 6-fold spatial symmetry using micromagnetic simulations and the finite element method. Onion and domain-wall magnetic states were tailored by sample shape and guided by an applied magnetic field with a fixed in-plane direction. Different directions of externally applied magnetic fields revealed a tendency for stability or nonstability of the considered states. -- Highlights: ► In a ferromagnetic wire sample six stable states at remanence were discovered. ► Presented wires provide new effects not met in classical thin-layered solutions. ► The mechanism of working results from competing demagnetizing and exchange fields. ► For different physical conditions onion and domain-wall states were observed. ► Wire samples of 6-fold symmetry can lead to many-level information storage devices

  5. Six-state, three-level, six-fold ferromagnetic wire system

    Energy Technology Data Exchange (ETDEWEB)

    Blachowicz, T., E-mail: tomasz.blachowicz@polsl.pl [Institute of Physics, Silesian University of Technology, 44-100 Gliwice (Poland); Ehrmann, A. [Faculty of Textile and Clothing Technology, Niederrhein University of Applied Sciences, 41065 Mönchengladbach (Germany)

    2013-04-15

    Six stable states at remanence were identified in iron wire samples of 6-fold spatial symmetry using micromagnetic simulations and the finite element method. Onion and domain-wall magnetic states were tailored by sample shape and guided by an applied magnetic field with a fixed in-plane direction. Different directions of externally applied magnetic fields revealed a tendency for stability or nonstability of the considered states. -- Highlights: ► In a ferromagnetic wire sample six stable states at remanence were discovered. ► Presented wires provide new effects not met in classical thin-layered solutions. ► The mechanism of working results from competing demagnetizing and exchange fields. ► For different physical conditions onion and domain-wall states were observed. ► Wire samples of 6-fold symmetry can lead to many-level information storage devices.

  6. A Vehicle Haptic Steering by Wire System Based on High Gain GPI Observers

    Directory of Open Access Journals (Sweden)

    A. Rodriguez-Angeles

    2014-01-01

    Full Text Available A vehicle steering by wire (SBW haptic system based on high gain generalized proportional integral (GPI observers is introduced. The observers are considered for the estimation of dynamic perturbations that are present at the tire and steering wheel. To ensure efficient tracking between the commanded steering wheel angle and the tire orientation angle, the estimated perturbations are on line canceled. As to provide a haptic interface with the driver, the estimated dynamic effects at the steering rack are fed back to the steering wheel, yielding a master-slave haptic system with bilateral communication. For implementation purposes few sensors and minimum knowledge of the dynamic model are required, which is a major advantage compared to other approaches. Only position tracking errors are fed back, while all other signals are estimated by the high gain GPI observers. The scheme is robust to uncertainty on the input gain and cancels dynamic perturbation effects such as friction and aligning forces on the tire. Experimental results are presented on a prototype platform.

  7. Non-linear Imaging using an Experimental Synthetic Aperture Real Time Ultrasound Scanner

    DEFF Research Database (Denmark)

    Rasmussen, Joachim; Du, Yigang; Jensen, Jørgen Arendt

    2011-01-01

    This paper presents the first non-linear B-mode image of a wire phantom using pulse inversion attained via an experimental synthetic aperture real-time ultrasound scanner (SARUS). The purpose of this study is to implement and validate non-linear imaging on SARUS for the further development of new...... non-linear techniques. This study presents non-linear and linear B-mode images attained via SARUS and an existing ultrasound system as well as a Field II simulation. The non-linear image shows an improved spatial resolution and lower full width half max and -20 dB resolution values compared to linear...

  8. Acquisition of Turbulence Data Using the DST Group Constant-Temperature Hot-Wire Anemometer System

    Science.gov (United States)

    2015-10-01

    Defence Science and Technology Group 506 Lorimer St Fishermans Bend , Victoria 3207 Australia Telephone: 1300 333 362 Fax: (03) 9626 7999...to both tensile and torsional loading. He joined the Aeronautical Research Laboratories (now called the Defence Science and Technology Group) in...the temperature becomes too high. A resistance ratio of 2 is generally used for Wollaston wire. The resistance of the wire and the leads combined

  9. Towards plant wires.

    Science.gov (United States)

    Adamatzky, Andrew

    2014-08-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self-growing wetware circuits and devices, and integration of plant-based electronic components into future and emergent bio-hybrid systems. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Randomized prospective study of olecranon fracture fixation: cable pin system versus tension band wiring.

    Science.gov (United States)

    Liu, Q-H; Fu, Z-G; Zhou, J-L; Lu, T; Liu, T; Shan, L; Liu, Y; Bai, L

    2012-01-01

    This prospective, randomized study compared the effectiveness of the cable pin system (CPS) versus tension band wiring (TBW) for olecranon fracture fixation. Patients with acute transverse or slight oblique olecranon fractures were randomly divided into two groups: one fixed by CPS and the other by TBW. Clinical outcome data were collected and analysed following a mean duration of 21 months. The mean ± SD fracture healing time was significantly shorter in the CPS group (n = 30; 9.73 ± 2.02 weeks) compared with the TBW group (n = 32; 11.13 ± 2.21 weeks). One patient in the CPS group and seven patients in the TBW group experienced postoperative complications; this difference was statistically significant. The mean ± SD Mayo Elbow Performance Score in the CPS group was significantly higher (88.67 ± 6.42) than that in the TBW group (80.78 ± 11.99). Logistic regression analysis showed an association between fixation method and fracture healing time, complications and elbow function. Internal fixation by CPS is an effective method for olecranon fracture and is associated with a shorter healing time, fewer complications and better function than TBW.

  11. Upgrading from the Dicon Wiring Management system to IntEC at the Gentilly 2 station

    International Nuclear Information System (INIS)

    Theoret, P.A.

    1995-01-01

    The General Electric DICON Wiring Management system supplied to HQ during the construction of G2 is currently being replaced by the stand-alone version of the IntEC software developed by AECL. The reasons for replacing DICON and choosing lntEC are discussed. The different aspects of the two year DICON data conversion project are presented with the problems encountered and the means that were taken to resolve the problems. lntEC has shown our DICON data to be considerably more deficient than we had thought. This has increased the cost and the duration of the conversion process. However, correcting the errors during the conversion process provides us with much more accurate data. This should be viewed as an investment in configuration management. Many potential causes of future errors and potentially critical path delays have been removed. We have chosen to document the detailed procedures for the use of lntEC in our plant using a Windows Help File compiler. This also has been found to be extremely useful as a training tool as well as providing on-line help. The DICON data conversion into lntEC will not be completed until 1996. lntEC is not perfect. However, from what we have up to now, we are satisfied with the conviviality and efficiency of lntEC and with AECL's diligence in constantly aspiring in making it a better product. (author)

  12. Online optimized hysteresis-based steering feel model for steer-by-wire systems

    Directory of Open Access Journals (Sweden)

    Ahmet Kirli

    2016-06-01

    Full Text Available In rubber-wheeled road vehicles, the mechanical connection between steering wheel and front wheels provides steering-related feedback to the driver. The torque fed back to the driver through the steering linkages and steering wheel, which is called steering feel, helps the driver in controlling the vehicle. The torque feedback is reproduced via artificial methods in steer-by-wire systems due to the lack of mechanical connection. In this work, in order to minimize the physical workload and the lateral acceleration under the consideration of handling performance, optimization of a hysteresis-based steering feel has been studied. A 2-degree-of-freedom bicycle model based on the magic formula tire model has been used for simulations and hardware-in-the-loop experiments. A mathematical model is proposed in order to create an adaptive model-based optimization of the hysteresis parameters simultaneously while driving. A hardware-in-the-loop experimental setup has been used for the driving tests. The weave and the double-lane change tests have been performed with different drivers in order to demonstrate and quantify the optimization methods that are presented in this work.

  13. Design of a hybrid (wired/wireless) acquisition data system for monitoring of cultural heritage physical parameters in Smart Cities.

    Science.gov (United States)

    García Diego, Fernando-Juan; Esteban, Borja; Merello, Paloma

    2015-03-25

    Preventive conservation represents a working method and combination of techniques which helps in determining and controlling the deterioration process of cultural heritage in order to take the necessary actions before it occurs. It is acknowledged as important, both in terms of preserving and also reducing the cost of future conservation measures. Therefore, long-term monitoring of physical parameters influencing cultural heritage is necessary. In the context of Smart Cities, monitoring of cultural heritage is of interest in order to perform future comparative studies and load information into the cloud that will be useful for the conservation of other heritage sites. In this paper the development of an economical and appropriate acquisition data system combining wired and wireless communication, as well as third party hardware for increased versatility, is presented. The device allows monitoring a complex network of points with high sampling frequency, with wired sensors in a 1-wire bus and a wireless centralized system recording data for monitoring of physical parameters, as well as the future possibility of attaching an alarm system or sending data over the Internet. This has been possible with the development of three board's designs and more than 5000 algorithm lines. System tests have shown an adequate system operation.

  14. Design of a Hybrid (Wired/Wireless Acquisition Data System for Monitoring of Cultural Heritage Physical Parameters in Smart Cities

    Directory of Open Access Journals (Sweden)

    Fernando-Juan García Diego

    2015-03-01

    Full Text Available Preventive conservation represents a working method and combination of techniques which helps in determining and controlling the deterioration process of cultural heritage in order to take the necessary actions before it occurs. It is acknowledged as important, both in terms of preserving and also reducing the cost of future conservation measures. Therefore, long-term monitoring of physical parameters influencing cultural heritage is necessary. In the context of Smart Cities, monitoring of cultural heritage is of interest in order to perform future comparative studies and load information into the cloud that will be useful for the conservation of other heritage sites. In this paper the development of an economical and appropriate acquisition data system combining wired and wireless communication, as well as third party hardware for increased versatility, is presented. The device allows monitoring a complex network of points with high sampling frequency, with wired sensors in a 1-wire bus and a wireless centralized system recording data for monitoring of physical parameters, as well as the future possibility of attaching an alarm system or sending data over the Internet. This has been possible with the development of three board’s designs and more than 5000 algorithm lines. System tests have shown an adequate system operation.

  15. Safety-technical comparison of a hard-wired dynamic reactor protection system with a computerized alternative. Pt. 2

    International Nuclear Information System (INIS)

    Buettner, W.E.

    1978-03-01

    The investigation presented here compares a conventional hard-wired dynamic reactor protection system with a computerized alternative. For both systems the spurious trip probability is determined, i.e. the probability of a false release of one or more protection actions due to failures. The mean unavailability is also determined for those not distinctly safety-oriented protection actions of the computerized protection system which are released via the open circuit current principle. This is because system breakdowns prevent the release of those protection actions in case of demand. The advantages and disadvantages of either type of system are viewed against each other. (orig.) [de

  16. Stability region of closed-loop pilot-vehicle system for fly-by-wire aircraft with limited actuator rate

    OpenAIRE

    Ying-hui, Li; Liang, Qu; Hao-jun, Xu; Qi-meng, Cao

    2017-01-01

    The category-II PIO (Pilot Induced Oscillations) caused by actuator rate limitation of fly-by-wire airplanes will badly threaten the flight safety. The stability regions of closed-loop pilot-vehicle (CLPV) system with rate limited actuator were studied in this paper to assess stability of such CLPV system. The augmented state  variables were introduced to segregate the rate limited element from the primary  system in order to build the saturation nonlinear model of CLPV system. To get the max...

  17. Working with Systems and Thinking Systemically--Disentangling the Crossed Wires

    Science.gov (United States)

    Fox, Mark

    2009-01-01

    This article explores two separate traditions that educational psychologists (EPs) in the UK have for working with systems. One of these is "systems work" with organisations such as schools. The other is "systemic thinking" for working with families. Over the years these two traditions, systems work and systemic thinking, have…

  18. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  19. Comparison of digital intraoral scanners by single-image capture system and full-color movie system.

    Science.gov (United States)

    Yamamoto, Meguru; Kataoka, Yu; Manabe, Atsufumi

    2017-01-01

    The use of dental computer-aided design/computer-aided manufacturing (CAD/CAM) restoration is rapidly increasing. This study was performed to evaluate the marginal and internal cement thickness and the adhesive gap of internal cavities comprising CAD/CAM materials using two digital impression acquisition methods and micro-computed tomography. Images obtained by a single-image acquisition system (Bluecam Ver. 4.0) and a full-color video acquisition system (Omnicam Ver. 4.2) were divided into the BL and OM groups, respectively. Silicone impressions were prepared from an ISO-standard metal mold, and CEREC Stone BC and New Fuji Rock IMP were used to create working models (n=20) in the BL and OM groups (n=10 per group), respectively. Individual inlays were designed in a conventional manner using designated software, and all restorations were prepared using CEREC inLab MC XL. These were assembled with the corresponding working models used for measurement, and the level of fit was examined by three-dimensional analysis based on micro-computed tomography. Significant differences in the marginal and internal cement thickness and adhesive gap spacing were found between the OM and BL groups. The full-color movie capture system appears to be a more optimal restoration system than the single-image capture system.

  20. A study of the dose modulation systems in two multislice CT scanners; Estudio de los sistemas de modulacion de dosis en dos equipos de tomografia computarizada multicorte

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Giron, I.; Valverde Moran, J.; Mendez Fernandez, R.; Aramburu Nunez, D.; Nunez Villavicencio, C.; Calzado Cantera, A.

    2009-07-01

    Multislice computed tomography (TCMC) is a technique that for its gradual introduction and the spectacular increase in its indications in clinical practice represents the main contribution to the collective dose in diagnostic radiology. It is essential to optimize the protocols maintaining doses as low as possible without affecting the diagnostic quality of images. Automatic tube current modulation systems are a tool currently available in all CT scanners. They adapt the tube current to morphological characteristics of the patient and the anatomical area under study. The aim of this work has been to analyze two scanners from the same manufacturer and featuring similar geometry by assessing the relative dose differences and image quality. Modulation systems of general use can decrease the dose in a 20-60% with a reduction in the signal to noise ratio between 6% and 37%. Dedicated cardiac-CT modulation system gave rise to high relative differences (36-40%) even when varying the heart rate. Significant changes in image quality were not appreciated though the motion of the heart has not been simulated in this study. (Author) 14 refs.

  1. A PET system based on 2-18FDG production with a low energy electrostatic proton accelerator and a dual headed PET scanner.

    Science.gov (United States)

    Sandell, A; Ohlsson, T; Erlandsson, K; Hellborg, R; Strand, S E

    1992-01-01

    We have developed a comparatively inexpensive PET system, based on a rotating scanner with two scintillation camera heads, and a nearby low energy electrostatic proton accelerator for production of short-lived radionuclides. Using a 6 MeV proton beam of 5 microA, and by optimization of the target geometry for the 18O(p,n)18F reaction, 750 MBq of 2-18FDG can be obtained. The PET scanner shows a spatial resolution of 6 mm (FWHM) and a sensitivity of 80 s-1kBq-1ml-1 (3 kcps/microCi/ml). Various corrections are included in the imaging process, to compensate for spatial and temporal response variations in the detector system. Both filtered backprojection and iterative reconstruction methods are employed. Clinical studies have been performed with acquisition times of 30-40 min. The system will be used for clinical experimental research with short- as well as long-lived positron emitters. Also the possibility of true 3D reconstruction is under evaluation.

  2. An Advanced Fly-By-Wire Flight Control System for the RASCAL Research Rotorcraft: Concept to Reality

    Science.gov (United States)

    Rediess, Nicholas A.; Dones, Fernando; McManus, Bruce L.; Ulmer, Lon; Aiken, Edwin W. (Technical Monitor)

    1995-01-01

    Design features of a new fly-by-wire flight control system for the Rotorcraft-Aircrew Systems Concepts Airborne Laboratory (RASCAL) are described. Using a UH-60A Black Hawk helicopter as a baseline vehicle, the RASCAL will be a flying laboratory capable of supporting the research requirements of major NASA and Army guidance, control, and display research programs. The paper describes the research facility requirements of these pro-rams and the design implementation of the research flight control system (RFCS), with emphasis on safety-of-flight, adaptability to multiple requirements and performance considerations.

  3. Design and flight experience with a digital fly-by-wire control system in an F-8 airplane

    Science.gov (United States)

    Deets, D. A.; Szalai, K. J.

    1974-01-01

    A digital fly-by-wire flight control system was designed, built, and for the first time flown in an airplane. The system, which uses components from the Apollo guidance system, is installed in an F-8 airplane as the primary control system. A lunar module guidance computer is the central element in the three-axis, single-channel, multimode, digital control system. A triplex electrical analog system which provides unaugmented control of the airplane is the only backup to the digital system. Flight results showed highly successful system operation, although the trim update rate was inadequate for precise trim changes, causing minor concern. The use of a digital system to implement conventional control laws proved to be practical for flight. Logic functions coded as an integral part of the control laws were found to be advantageous. Although software verification required extensive effort, confidence in the software was achieved.

  4. [Developing a home care nursing information system by utilizing wire-wireless network and mobile computing system].

    Science.gov (United States)

    Park, Jung-Ho; Park, Sung-Ae; Yoon, Soon-Nyoung; Kang, Sung-Rye

    2004-04-01

    The purpose of this study was to develop a home care nursing network system for operating home care effectively and efficiently by utilizing a wire-wireless network and mobile computing in order to record and send patients' data in real time, and by combining the headquarter office and the local offices with home care nurses over the Internet. It complements the preceding research from 1999 by adding home care nursing standard guidelines and upgrading the PDA program. Method/1 and Prototyping were adopted to develop the main network system. The detailed research process is as follows : 1)home care nursing standard guidelines for Diabetes, cancer and peritoneal-dialysis were added in 12 domains of nursing problem fields with nursing assessment/intervention algorithms. 2) complementing the PDA program was done by omitting and integrating the home care nursing algorithm path which is unnecessary and duplicated. Also, upgrading the PDA system was done by utilizing the machinery and tools where the PDA and the data transmission modem are integrated, CDMX-1X base construction, in order to reduce a transmission error or transmission failure.

  5. Cognition for robot scanner based remote welding

    Science.gov (United States)

    Thombansen, U.; Ungers, Michael

    2014-02-01

    The effort for reduced cycle times in manufacturing has supported the development of remote welding systems which use a combination of scanners for beam delivery and robots for scanner positioning. Herein, close coupling of both motions requires a precise command of the robot trajectory and the scanner positioning to end up with a combined beam delivery. Especially the path precision of the robot plays a vital role in this kinematic chain. In this paper, a sensor system is being presented which allows tracking the motion of the laser beam against the work piece. It is based on a camera system which is coaxially connected to the scanner thus observing the relative motion of the laser beam relative to the work piece. The acquired images are processed with computer vision algorithms from the field of motion detection. The suitability of the algorithms is being demonstrated with a motion tracking tool which visualizes the homogeneity of the tracking result. The reported solution adds cognitive capabilities to manufacturing systems for robot scanner based materials processing. It allows evaluation of the relative motion between work piece and the laser beam. Moreover, the system can be used to adapt system programming during set-up of a manufacturing task or to evaluate the functionality of a manufacturing system during production. The presented sensor system will assist in optimizing manufacturing processes.

  6. Charge transport in organic materials: From molecular wire to 3D systems

    Czech Academy of Sciences Publication Activity Database

    Nešpůrek, Stanislav; Toman, Petr; Menšík, Miroslav; Kratochvílová, Irena; Sworakowski, J.; Mallouk, T. E.

    2007-01-01

    Roč. 9, č.1 (2007), s. 134-140 ISSN 1454-4164 R&D Projects: GA AV ČR KAN401770651; GA AV ČR IAA401770601 Grant - others:Polish Ministry of Science(PL) 3T08E 08430 Institutional research plan: CEZ:AV0Z40500505; CEZ:AV0Z10100520 Keywords : charge transport * molecular wire * polaron Subject RIV: CD - Macromolecular Chemistry Impact factor: 0.827, year: 2007

  7. Ionization beam scanner

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Inner structure of an ionization beam scanner, a rather intricate piece of apparatus which permits one to measure the density distribution of the proton beam passing through it. On the outside of the tank wall there is the coil for the longitudinal magnetic field, on the inside, one can see the arrangement of electrodes creating a highly homogeneous transverse electric field.

  8. Put Your Cable Wiring to the Test.

    Science.gov (United States)

    Day, C. William

    2001-01-01

    Discusses why schools and universities should use testing procedures in any wire bid specification for cable wiring and also know how experienced the installers are in testing and installing structured cabling systems. Key cabling terms are included. (GR)

  9. Quality of Metal Deposited Flux Cored Wire With the System Fe-C-Si-Mn-Cr-Mo-Ni-V-Co

    Science.gov (United States)

    Gusev, Aleksander I.; Kozyrev, Nikolay A.; Osetkovskiy, Ivan V.; Kryukov, Roman E.; Kozyreva, Olga A.

    2017-10-01

    Studied the effect of the introduction of vanadium and cobalt into the charge powder fused wire system Fe-C-Si-Mn-Cr-Ni-Mo-V, used in cladding assemblies and equipment parts and mechanisms operating under abrasive and abrasive shock loads. the cored wires samples were manufactured in the laboratory conditions and using appropriate powder materials and as a carbonfluoride contained material were used the dust from gas purification of aluminum production, with the following components composition, %: Al2O3 = 21-46.23; F = 18-27; Na2O = 8-15; K2O = 0.4-6; CaO = 0.7-2.3; Si2O = 0.5-2.48; Fe2O3 = 2.1-3.27; C = 12.5-30.2; MnO = 0.07-0.9; MgO = 0.06-0.9; S = 0.09-0.19; P = 0.1-0.18. Surfacing was produced on the St3 metal plates in 6 layers under the AN-26C flux by welding truck ASAW-1250. Cutting and preparation of samples for research had been implemented. The chemical composition and the hydrogen content of the weld metal were determined by modern methods. The hardness and abrasion rate of weld metal had been measured. Conducted metallographic studies of weld metal: estimated microstructure, grain size, contamination of oxide non-metallic inclusions. Metallographic studies showed that the microstructure of the surfaced layer by cored wire system Fe-C-Si-Mn-Cr-Mo-Ni-V-Co is uniform, thin dendrite branches are observed. The microstructure consists of martensite, which is formed inside the borders of the former austenite grain retained austenite present in small amounts in the form of separate islands, and thin layers of δ-ferrite, which is located on the borders of the former austenite grains. Carried out an assessment the effect of the chemical composition of the deposited metal on the hardness and wear and hydrogen content. In consequence of multivariate correlation analysis, it was determined dependence to the hardness of the deposited layer and the wear resistance of the mass fraction of the elements included in the flux-cored wires of the system Fe

  10. A Comparative Field Monitoring of Column Shortenings in Tall Buildings Using Wireless and Wired Sensor Network Systems

    Directory of Open Access Journals (Sweden)

    Sungho Lee

    2016-01-01

    Full Text Available A comparative field measurement for column shortening of tall buildings is presented in this study, with a focus on the reliability and stability of a wireless sensor network. A wireless sensor network was used for monitoring the column shortenings of a 58-story building under construction. The wireless sensor network, which was composed of sensor and master nodes, employed the ultra-high-frequency band and CDMA communication methods. To evaluate the reliability and stability of the wireless sensor network system, the column shortenings were also measured using a conventional wired monitoring system. Two vibration wire gauges were installed in each of the selected 7 columns and 3 walls. Measurements for selected columns and walls were collected for 270 days after casting of the concrete. The results measured by the wireless sensor network were compared with the results of the conventional method. The strains and column shortenings measured using both methods showed good agreement for all members. It was verified that the column shortenings of tall buildings could be monitored using the wireless sensor network system with its reliability and stability.

  11. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  12. Thermal surveillance of Cascade Range volcanoes using ERTS-1 multispectral scanner, aircraft imaging systems, and ground-based data communication platforms

    Science.gov (United States)

    Friedman, J. D.; Frank, D. G.; Preble, D.; Painter, J. E.

    1973-01-01

    A combination of infrared images depicting areas of thermal emission and ground calibration points have proved to be particularly useful in plotting time-dependent changes in surface temperatures and radiance and in delimiting areas of predominantly convective heat flow to the earth's surface in the Cascade Range and on Surtsey Volcano, Iceland. In an integrated experiment group using ERTS-1 multispectral scanner (MSS) and aircraft infrared imaging systems in conjunction with multiple thermistor arrays, volcano surface temperatures are relayed daily to Washington via data communication platform (DCP) transmitters and ERTS-1. ERTS-1 MSS imagery has revealed curvilinear structures at Lassen, the full extent of which have not been previously mapped. Interestingly, the major surface thermal manifestations at Lassen are aligned along these structures, particularly in the Warner Valley.

  13. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  14. MEMS temperature scanner: principles, advances, and applications

    Science.gov (United States)

    Otto, Thomas; Saupe, Ray; Stock, Volker; Gessner, Thomas

    2010-02-01

    Contactless measurement of temperatures has gained enormous significance in many application fields, ranging from climate protection over quality control to object recognition in public places or military objects. Thereby measurement of linear or spatially temperature distribution is often necessary. For this purposes mostly thermographic cameras or motor driven temperature scanners are used today. Both are relatively expensive and the motor drive devices are limited regarding to the scanning rate additionally. An economic alternative are temperature scanner devices based on micro mirrors. The micro mirror, attached in a simple optical setup, reflects the emitted radiation from the observed heat onto an adapted detector. A line scan of the target object is obtained by periodic deflection of the micro scanner. Planar temperature distribution will be achieved by perpendicularly moving the target object or the scanner device. Using Planck radiation law the temperature of the object is calculated. The device can be adapted to different temperature ranges and resolution by using different detectors - cooled or uncooled - and parameterized scanner parameters. With the basic configuration 40 spatially distributed measuring points can be determined with temperatures in a range from 350°C - 1000°C. The achieved miniaturization of such scanners permits the employment in complex plants with high building density or in direct proximity to the measuring point. The price advantage enables a lot of applications, especially new application in the low-price market segment This paper shows principle, setup and application of a temperature measurement system based on micro scanners working in the near infrared range. Packaging issues and measurement results will be discussed as well.

  15. Quality assurance of computed tomography (CT) scanners

    International Nuclear Information System (INIS)

    Sankaran, A.; Sanu, K.K. . Email : a_sankaran@vsnl.com

    2004-01-01

    This article reviews the present status of research work and development of various test objects, phantoms and detector/instrumentation systems for quality assurance (QA) of computed tomography (CT) scanners, carried out in advanced countries, with emphasis on similar work done in this research centre. CT scanner is a complex equipment and routine quality control procedures are essential to the maintenance of image quality with optimum patient dose. Image quality can be ensured only through correlation between prospective monitoring of system components and tests of overall performance with standard phantoms. CT examinations contribute a large share to the population dose in advanced countries. The unique dosimetry problems in CT necessitate special techniques. This article describes a comprehensive kit developed indigenously for the following QA and type approval tests as well as for research studies on image quality/dosimetry on CT scanners

  16. Bias Impact Analysis and Calibration of UAV-Based Mobile LiDAR System with Spinning Multi-Beam Laser Scanner

    Directory of Open Access Journals (Sweden)

    Radhika Ravi

    2018-02-01

    Full Text Available Light Detection and Ranging (LiDAR is a technology that uses laser beams to measure ranges and generates precise 3D information about the scanned area. It is rapidly gaining popularity due to its contribution to a variety of applications such as Digital Building Model (DBM generation, telecommunications, infrastructure monitoring, transportation corridor asset management and crash/accident scene reconstruction. To derive point clouds with high positional accuracy, estimation of mounting parameters relating the laser scanners to the onboard Global Navigation Satellite System/Inertial Navigation System (GNSS/INS unit, i.e., the lever-arm and boresight angles, is the foremost and necessary step. This paper proposes a LiDAR system calibration strategy for a Unmanned Aerial Vehicle (UAV-based mobile mapping system that can directly estimate the mounting parameters for spinning multi-beam laser scanners through an outdoor calibration procedure. This approach is based on the use of conjugate planar/linear features in overlapping point clouds derived from different flight lines. Designing an optimal configuration for calibration is the first and foremost step in order to ensure the most accurate estimates of mounting parameters. This is achieved by conducting a rigorous theoretical analysis of the potential impact of bias in mounting parameters of a LiDAR unit on the resultant point cloud. The dependency of the impact on the orientation of target primitives and relative flight line configuration would help in deducing the configuration that would maximize as well as decouple the impact of bias in each mounting parameter so as to ensure their accurate estimation. Finally, the proposed analysis and calibration strategy are validated by calibrating a UAV-based LiDAR system using two different datasets—one acquired with flight lines at a single flying height and the other with flight lines at two different flying heights. The calibration performance is

  17. Impact of wire metasurface eigenmode on the sensitivity enhancement of MRI system

    Science.gov (United States)

    Kretov, Egor I.; Shchelokova, Alena V.; Slobozhanyuk, Alexey P.

    2018-01-01

    The sensitivity of magnetic resonance imaging (MRI) is dictated by the signal-to-noise ratio. It was recently noted that the signal-to-noise ratio could be substantially increased via excitation of certain metasurface eigenmodes. Here, we provide a detailed discussion of the wire metasurface eigenmode impact on the sensitivity of MRI. We experimentally show that due to the spatial redistribution of the electromagnetic near field, mediated by the metasurface eigenmode, the received signal from the studied object becomes essentially dependent on its position on the metasurface. Moreover, we analyzed how the metasurface performance significantly depends on the dimensions of an examined object. Our work provides metasurface design guidelines for substantial enhancement of MRI sensitivity.

  18. Four-branch Star Hybrid Power Filter for Three-phase Four-wire Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Teodorescu, Remus; Rodriguez, Pedro

    2008-01-01

    , with two different and simultaneous resonance frequencies and sequences, is achieved -one frequency for positive-/negative- sequence and another one for zero-sequence components. This filter topology can work either as a passive filter or as a hybrid filter. The paper analyzes the proposed topology...... results is conducted in order to verify and validate the good performance of the proposed four-branch star passive/hybrid power filter.......This paper presents a new concept for filtering current harmonics in three-phase four-wire networks. The four-branch star (FBS) filtering topology presented in this work is characterized by a particular layout consisting of single-phase inductances and capacitors. Via this layout, a power filter...

  19. Steer-by-wire steering system with enhanced functionality for rear steered vehicles

    Directory of Open Access Journals (Sweden)

    Christoph Dillmann

    2015-12-01

    Full Text Available Heckgelenkte selbstfahrende Erntemaschinen sind die zentralen Elemente moderner Ernteketten in der Landwirtschaft. Das primär auf Bodenschonung ausgelegte Fahrwerk, die aktuelle Höchstgeschwindigkeit von 40 km/h sowie die systembedingten, fahrdynamischen Nachteile einer heckgelenkten Maschine erschweren jedoch die Fahrzeugführung auf der Straße. Das Spurhalten und Stabilisieren erfordert daher viel Erfahrung und eine hohe Konzentration des Fahrers. Fahrdynamiksysteme können den Fahrzeugführer entlasten und somit das Fahren mit hohen Geschwindigkeiten sicherer und komfortabler gestalten. Im hier vorgestellten Projekt wird in diesem Kontext eine Steer-by-wire-Lenkung mit parametrierbarer Lenkcharakteristik vorgestellt, die auf die unterschiedlichen Vorzüge des Fahrers einstellbar ist und fahrzustandsabhängige Informationen über das Lenkrad an den Bediener übermittelt.

  20. Gamma scanner conceptual design report

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1979-11-01

    The Fuels and Materials Examination Facility (FMEF) will include several stations for the nondestructive examination of irradiated fuels. One of these stations will be the gamma scanner which will be employed to detect gamma radiation from the irradiated fuel pins. The conceptual design of the gamma scan station is described. The gamma scanner will use a Standard Exam Stage (SES) as a positioner and transport mechanism for the fuel pins which it will obtain from a magazine. A pin guide mechanism mounted on the face of the collimator will assure that the fuel pins remain in front of the collimator during scanning. The collimator has remotely adjustable tungsten slits and can be manually rotated to align the slit at various angles. A shielded detector cart located in the operating corridor holds an intrinsic germanium detector and associated sodium-iodide anticoincidence detector. The electronics associated with the counting system consist of standard NIM modules to process the detector signals and a stand-alone multichannel analyzer (MCA) for counting data accumulation. Data from the MCA are bussed to the station computer for analysis and storage on magnetic tape. The station computer controls the collimator, the MCA, a source positioner and the SES through CAMAC-based interface hardware. Most of the electronic hardware is commercially available but some interfaces will require development. Conceptual drawings are included for mechanical hardware that must be designed and fabricated

  1. Radiation dosimetry of computed tomography x-ray scanners

    International Nuclear Information System (INIS)

    Poletti, J.L.; Williamson, B.D.P.; Le Heron, J.C.

    1983-01-01

    This report describes the development and application of the methods employed in National Radiation Laboratory (NRL) surveys of computed tomography x-ray scanners (CT scanners). It includes descriptions of the phantoms and equipment used, discussion of the various dose parameters measured, the principles of the various dosimetry systems employed and some indication of the doses to occupationally exposed personnel

  2. Verification of a CT scanner using a miniature step gauge

    DEFF Research Database (Denmark)

    Cantatore, Angela; Andreasen, J.L.; Carmignato, S.

    2011-01-01

    The work deals with performance verification of a CT scanner using a 42mm miniature replica step gauge developed for optical scanner verification. Errors quantification and optimization of CT system set-up in terms of resolution and measurement accuracy are fundamental for use of CT scanning...

  3. Performance of single wire earth return transformers with amorphous alloy core in a rural electric energy distribution system

    Directory of Open Access Journals (Sweden)

    Benedito Antonio Luciano

    2012-10-01

    Full Text Available In this paper are presented some considerations about the performance of single wire earth return amorphous alloy core transformers in comparison with conventional silicon steel sheets cores transformers used in rural electric energy distribution network. It has been recognized that amorphous metal core transformers improve electrical power distribution efficiency by reducing transformer core losses. This reduction is due to some electromagnetic properties of the amorphous alloys such as: high magnetic permeability, high resistivity, and low coercivity. Experimental results obtained with some single-phase, 60 Hz, 5 kVA amorphous core transformers installed in a rural area electric distribution system in Northern Brazil have been confirming their superior performance in comparison to identical nominal rated transformers built with conventional silicon steel cores, particularly with regard to the excitation power and to the no-load losses.

  4. Noncontextual Wirings

    Science.gov (United States)

    Amaral, Barbara; Cabello, Adán; Cunha, Marcelo Terra; Aolita, Leandro

    2018-03-01

    Contextuality is a fundamental feature of quantum theory necessary for certain models of quantum computation and communication. Serious steps have therefore been taken towards a formal framework for contextuality as an operational resource. However, the main ingredient of a resource theory—a concrete, explicit form of free operations of contextuality—was still missing. Here we provide such a component by introducing noncontextual wirings: a class of contextuality-free operations with a clear operational interpretation and a friendly parametrization. We characterize them completely for general black-box measurement devices with arbitrarily many inputs and outputs. As applications, we show that the relative entropy of contextuality is a contextuality monotone and that maximally contextual boxes that serve as contextuality bits exist for a broad class of scenarios. Our results complete a unified resource-theoretic framework for contextuality and Bell nonlocality.

  5. Emittance growth due to Tevatron flying wires

    Energy Technology Data Exchange (ETDEWEB)

    Syphers, M; Eddy, Nathan

    2004-06-01

    During Tevatron injection, Flying Wires have been used to measure the transverse beam size after each transfer from the Main Injector in order to deduce the transverse emittances of the proton and antiproton beams. This amounts to 36 + 9 = 45 flies of each of 3 wire systems, with an individual wire passing through each beam bunch twice during a single ''fly''. below they estimate the emittance growth induced by the interaction of the wires with the particles during these measurements. Changes of emittance from Flying Wire measurements conducted during three recent stores are compared with the estimations.

  6. How flatbed scanners upset accurate film dosimetry

    International Nuclear Information System (INIS)

    Van Battum, L J; Verdaasdonk, R M; Heukelom, S; Huizenga, H

    2016-01-01

    Film is an excellent dosimeter for verification of dose distributions due to its high spatial resolution. Irradiated film can be digitized with low-cost, transmission, flatbed scanners. However, a disadvantage is their lateral scan effect (LSE): a scanner readout change over its lateral scan axis. Although anisotropic light scattering was presented as the origin of the LSE, this paper presents an alternative cause. Hereto, LSE for two flatbed scanners (Epson 1680 Expression Pro and Epson 10000XL), and Gafchromic film (EBT, EBT2, EBT3) was investigated, focused on three effects: cross talk, optical path length and polarization. Cross talk was examined using triangular sheets of various optical densities. The optical path length effect was studied using absorptive and reflective neutral density filters with well-defined optical characteristics (OD range 0.2–2.0). Linear polarizer sheets were used to investigate light polarization on the CCD signal in absence and presence of (un)irradiated Gafchromic film. Film dose values ranged between 0.2 to 9 Gy, i.e. an optical density range between 0.25 to 1.1. Measurements were performed in the scanner’s transmission mode, with red–green–blue channels. LSE was found to depend on scanner construction and film type. Its magnitude depends on dose: for 9 Gy increasing up to 14% at maximum lateral position. Cross talk was only significant in high contrast regions, up to 2% for very small fields. The optical path length effect introduced by film on the scanner causes 3% for pixels in the extreme lateral position. Light polarization due to film and the scanner’s optical mirror system is the main contributor, different in magnitude for the red, green and blue channel. We concluded that any Gafchromic EBT type film scanned with a flatbed scanner will face these optical effects. Accurate dosimetry requires correction of LSE, therefore, determination of the LSE per color channel and dose delivered to the film. (paper)

  7. Micro-optical design of a three-dimensional microlens scanner for vertically integrated micro-opto-electro-mechanical systems.

    Science.gov (United States)

    Baranski, Maciej; Bargiel, Sylwester; Passilly, Nicolas; Gorecki, Christophe; Jia, Chenping; Frömel, Jörg; Wiemer, Maik

    2015-08-01

    This paper presents the optical design of a miniature 3D scanning system, which is fully compatible with the vertical integration technology of micro-opto-electro-mechanical systems (MOEMS). The constraints related to this integration strategy are considered, resulting in a simple three-element micro-optical setup based on an afocal scanning microlens doublet and a focusing microlens, which is tolerant to axial position inaccuracy. The 3D scanning is achieved by axial and lateral displacement of microlenses of the scanning doublet, realized by micro-electro-mechanical systems microactuators (the transmission scanning approach). Optical scanning performance of the system is determined analytically by use of the extended ray transfer matrix method, leading to two different optical configurations, relying either on a ball lens or plano-convex microlenses. The presented system is aimed to be a core component of miniature MOEMS-based optical devices, which require a 3D optical scanning function, e.g., miniature imaging systems (confocal or optical coherence microscopes) or optical tweezers.

  8. Improved quantitative MR thermometry using a 1.5-T scanner to monitor cooled applicator systems during laser-induced interstitial thermotherapy (LITT)

    Science.gov (United States)

    Busse, Harald; Rassek, Margarethe; Grust, Andreas; Kahn, Thomas; Schwarzmaier, Hans-Joachim

    1999-05-01

    Cooled LITT applicator systems are known to induce complex temperature patterns. Typical for such devices, the temperature maxima are often shifted away from the applicator into the tissue. Therefore, an adequate temperature monitoring is essential. This, however, has not yet been realized for many of the latest MRI systems. We have implemented an improved MR thermometry system using a gradient echo pulse sequence (5 mm slice, FOV 230 mm, TR/TE equals 80/26 ms, matrix 192 X 256) on a 1.5 T scanner (Magnetron Vision, Siemens, Erlangen, Germany). The recorded temperature expansion during laser irradiation of bovine liver was used as a model setup for LITT. A commercially available water-cooled applicator system (Microdome light guide, Huettinger, Umkirch, Germany, in combination with the Power Catheter, Somatex, Berlin, Germany) was used for the delivery of the Nd:YAG laser radiation ((lambda) equals 1064 nm, cw, 15.5 W, Dornier 4060N, Germering, Germany; tissue cooling, respectively. MR phase images were recorded every 30 seconds alternating in axial and radial orientation. The temperature distributions were calculated using the proton resonance frequency method. A sensitivity factor of 0.0097 ppm/ degree(s)C has been determined independently by a comparison with fluorooptic temperature measurements. The temperature accuracy of a single pixel (0.9 mm square) during 10 min laser irradiation of bovine liver tissue was found to be (-1.7 +/- 1.4) degree(s)C. The final lesion size diameters after 6 min laser irradiation (15 mm X 26 mm) were found to be in good agreement with the dimensions of the 60 degree(s)C isotherm of the respective 2D temperature map. This indicates that the implemented MR thermometry might be an essential tool for therapy control of interstitial laser treatment with cooled applicator systems.

  9. An assumed mode method and finite element method investigation of the coupled vibration in a flexible-disk rotor system with lacing wires

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Shui-Ting; Huang, Hong-Wu [Hunan University, Changsha (China); Chiu, Yi-Jui; Yu, Guo-Fei [Xiamen University of Technology, Xiamen (China); Yang, Chia-Hao [Taipei Chengshih University of Science and Technology, Taipei (China); Jian, Sheng-Rui [I-Shou University, Kaohsiung (China)

    2017-02-15

    The Assumed mode method (AMM) and Finite element method (FEM) were used. Their results were compared to investigate the coupled shaft-torsion, disk-transverse, and blade-bending vibrations in a flexible-disk rotor system. The blades were grouped with a spring. The flexible-disk rotor system was divided into three modes of coupled vibrations: Shaft-disk-blade, disk-blade, and blade-blade. Two new modes of coupled vibrations were introduced, namely, lacing wires-blade and lacing wires-disk-blade. The patterns of change of the natural frequencies and mode shapes of the system were discussed. The results showed the following: first, mode shapes and natural frequencies varied, and the results of the AMM and FEM differed; second, numerical calculation results showed three influencing factors on natural frequencies, namely, the lacing wire constant, the lacing wire location, and the flexible disk; lastly, the flexible disk could affect the stability of the system as reflected in the effect of the rotational speed.

  10. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  11. Scanner OPC signatures: automatic vendor-to-vendor OPE matching

    Science.gov (United States)

    Renwick, Stephen P.

    2009-03-01

    As 193nm lithography continues to be stretched and the k1 factor decreases, optical proximity correction (OPC) has become a vital part of the lithographer's tool kit. Unfortunately, as is now well known, the design variations of lithographic scanners from different vendors cause them to have slightly different optical-proximity effect (OPE) behavior, meaning that they print features through pitch in distinct ways. This in turn means that their response to OPC is not the same, and that an OPC solution designed for a scanner from Company 1 may or may not work properly on a scanner from Company 2. Since OPC is not inexpensive, that causes trouble for chipmakers using more than one brand of scanner. Clearly a scanner-matching procedure is needed to meet this challenge. Previously, automatic matching has only been reported for scanners of different tool generations from the same manufacturer. In contrast, scanners from different companies have been matched using expert tuning and adjustment techniques, frequently requiring laborious test exposures. Automatic matching between scanners from Company 1 and Company 2 has remained an unsettled problem. We have recently solved this problem and introduce a novel method to perform the automatic matching. The success in meeting this challenge required three enabling factors. First, we recognized the strongest drivers of OPE mismatch and are thereby able to reduce the information needed about a tool from another supplier to that information readily available from all modern scanners. Second, we developed a means of reliably identifying the scanners' optical signatures, minimizing dependence on process parameters that can cloud the issue. Third, we carefully employed standard statistical techniques, checking for robustness of the algorithms used and maximizing efficiency. The result is an automatic software system that can predict an OPC matching solution for scanners from different suppliers without requiring expert intervention.

  12. An Integrated Monitoring System Through 3d Laser Scanner and Traditional Instruments for Load Test on Arch Bridge

    Science.gov (United States)

    Pera, D.; Ferrando, I.

    2017-05-01

    The experimental campaign represents an example of how the careful design of the different test phases and the choice of the needed instrumentation are fundamental aspects to obtain a proper interpretation of the results, for future application on the real structures. Additionally, the present work represents a successful example of a combined monitoring system, integrating the traditional and innovative technical instrumentation for loading tests and geomatics survey techniques. The monitoring system has been designed with the aim of defining the load carrying capacity of a masonry arch bridge scaled model and to test the performances of a new retrofitting method. In particular, two different configuration have been considered: a first one with isolated arch and a second one with gravel fill on the arch.

  13. AN INTEGRATED MONITORING SYSTEM THROUGH 3D LASER SCANNER AND TRADITIONAL INSTRUMENTS FOR LOAD TEST ON ARCH BRIDGE

    Directory of Open Access Journals (Sweden)

    D. Pera

    2017-05-01

    Full Text Available The experimental campaign represents an example of how the careful design of the different test phases and the choice of the needed instrumentation are fundamental aspects to obtain a proper interpretation of the results, for future application on the real structures. Additionally, the present work represents a successful example of a combined monitoring system, integrating the traditional and innovative technical instrumentation for loading tests and geomatics survey techniques. The monitoring system has been designed with the aim of defining the load carrying capacity of a masonry arch bridge scaled model and to test the performances of a new retrofitting method. In particular, two different configuration have been considered: a first one with isolated arch and a second one with gravel fill on the arch.

  14. Analysis and databasing software for integrated tomographic gamma scanner (TGS) and passive-active neutron (PAN) assay systems

    International Nuclear Information System (INIS)

    Estep, R.J.; Melton, S.G.; Buenafe, C.

    2000-01-01

    The CTEN-FIT program, written for Windows 9x/NT in C++,performs databasing and analysis of combined thermal/epithermal neutron (CTEN) passive and active neutron assay data and integrates that with isotopics results and gamma-ray data from methods such as tomographic gamma scanning (TGS). The binary database is reflected in a companion Excel database that allows extensive customization via Visual Basic for Applications macros. Automated analysis options make the analysis of the data transparent to the assay system operator. Various record browsers and information displays simplify record keeping tasks

  15. Experimental MRI-SPECT insert system with Hybrid Semiconductor detectors Timepix for MR animal scanner Bruker 47/20

    Czech Academy of Sciences Publication Activity Database

    Zajíček, J.; Burian, M.; Soukup, P.; Novák, Vladimír; Macko, M.; Jakůbek, J.

    2017-01-01

    Roč. 12, January (2017), č. článku P01015. ISSN 1748-0221 Institutional support: RVO:68378297 Keywords : Gamma camera * SPECT * PET PET/CT * coronary CT angiography (CTA) * Gamma detectors (scintillators, CZT, HPG, HgI etc) * multi-modality systems * pixelated detectors and associated VLSI electronics Subject RIV: JB - Sensors, Measurment, Regulation OBOR OECD: Electrical and electronic engineering Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/12/01/P01015

  16. Beam profile assessment in spectral CT scanners.

    Science.gov (United States)

    Anjomrouz, Marzieh; Shamshad, Muhammad; Panta, Raj K; Broeke, Lieza Vanden; Schleich, Nanette; Atharifard, Ali; Aamir, Raja; Bheesette, Srinidhi; Walsh, Michael F; Goulter, Brian P; Bell, Stephen T; Bateman, Christopher J; Butler, Anthony P H; Butler, Philip H

    2018-03-01

    In this paper, we present a method that uses a combination of experimental and modeled data to assess properties of x-ray beam measured using a small-animal spectral scanner. The spatial properties of the beam profile are characterized by beam profile shape, the angular offset along the rotational axis, and the photon count difference between experimental and modeled data at the central beam axis. Temporal stability of the beam profile is assessed by measuring intra- and interscan count variations. The beam profile assessment method was evaluated on several spectral CT scanners equipped with Medipix3RX-based detectors. On a well-calibrated spectral CT scanner, we measured an integral count error of 0.5%, intrascan count variation of 0.1%, and an interscan count variation of less than 1%. The angular offset of the beam center ranged from 0.8° to 1.6° for the studied spectral CT scanners. We also demonstrate the capability of this method to identify poor performance of the system through analyzing the deviation of the experimental beam profile from the model. This technique can, therefore, aid in monitoring the system performance to obtain a robust spectral CT; providing the reliable quantitative images. Furthermore, the accurate offset parameters of a spectral scanner provided by this method allow us to incorporate a more realistic form of the photon distribution in the polychromatic-based image reconstruction models. Both improvements of the reliability of the system and accuracy of the volume reconstruction result in a better discrimination and quantification of the imaged materials. © 2018 MARS Bioimaging Ltd. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  17. Optical performance requirements for MEMS-scanner-based microdisplays

    Science.gov (United States)

    Urey, Hakan; Wine, David W.; Osborn, Thor D.

    2000-08-01

    High-resolution and high frame rate dynamic microdisplays can be implemented by scanning a photon beam in a raster format across the viewer's retina. Microvision is developing biaxial MEMS scanners for such video display applications. This paper discusses the optical performance requirements for scanning display systems. The display resolution directly translates into a scan-angle-mirror-size product and the frame rate translates into vertical and horizontal scanner frequencies. (theta) -product and fh are both very important figures of merit for scanner performance comparison. In addition, the static and dynamic flatness of the scanners, off-axis motion and scan repeatability, scanner position sensor accuracy all have a direct impact on display image quality.

  18. Transient switching control strategy from regenerative braking to anti-lock braking with a semi-brake-by-wire system

    Science.gov (United States)

    Li, Liang; Li, Xujian; Wang, Xiangyu; Liu, Yahui; Song, Jian; Ran, Xu

    2016-02-01

    Regenerative braking is an important technology in improving fuel economy of an electric vehicle (EV). However, additional motor braking will change the dynamic characteristics of the vehicle, leading to braking instability, especially when the anti-lock braking system (ABS) is triggered. In this paper, a novel semi-brake-by-wire system, without the use of a pedal simulator and fail-safe device, is proposed. In order to compensate for the hysteretic characteristics of the designed brake system while ensure braking reliability and fuel economy when the ABS is triggered, a novel switching compensation control strategy using sliding mode control is brought forward. The proposed strategy converts the complex coupling braking process into independent control of hydraulic braking and regenerative braking, through which a balance between braking performance, braking reliability, braking safety and fuel economy is achieved. Simulation results show that the proposed strategy is effective and adaptable in different road conditions while the large wheel slip rate is triggered during a regenerative braking course. The research provides a new possibility of low-cost equipment and better control performance for the regenerative braking in the EV and the hybrid EV.

  19. A mechanical system design of the iridium-192 isotope wire in cervical cancer brachytherapy with medium dose rate

    International Nuclear Information System (INIS)

    Ari Satmoko; Sanda; Tri Harjanto; Atang Susila

    2010-01-01

    In 2010, brachytherapy engineering development activities have a purpose to establish a detailed design of the cervical cancer brachytherapy with medium dose rate. The brachytherapy will use an Iridium-92 source with the emitting radiation of 5 to 10 Curies. The source is wrapped in SS-316 capsule and carried by a SS-316 wire having diameter of about 1 mm dan length of 1800 mm. As part of this activity, the preliminary design of the mechanical drive systems for the isotope source has been developed. The technical specifications for the main components of the mechanical drive system have been successfully determined. This is started by studying the concept design, performing calculations, determining technical specifications, and finally defining the main components. From the evaluation, some components were decided: a stepper motor PK264A1-SG10, needle bearing NKI-10/20, spiral tube in SS316-1/8'' with 120 mm in diameter, rubber-based belts with a width of 20 mm, and aluminium drum with a diameter of 100 mm. Not all components could be identified in detail, especially for the components that do not exist in the marketplace and have to be created ourself Since the main components have been identified, the detailed design step of the mechanical drive systems for the isotope source can be performed. (author)

  20. The mechanical system design of the iridium-192 isotope wire in cervical cancer brachytherapy with medium dose rate

    International Nuclear Information System (INIS)

    Ari Satmoko; Sanda; Tri Harjanto; Atang Susila

    2010-01-01

    In 2010, brachytherapy engineering activities have a purpose to establish a detailed design of the cervical cancer brachytherapy with medium dose rate. The brachytherapy will use an Iridium-92 source with the emiting radiation of 5 to 10 Curies. The source is wrapped in SS-316 capsule and carried by a SS-316 wire having diameter of about 1 mm dan length of 1800 mm. As part of this activity, the preliminary design of the mechanical drive systems for the isotope source has been developed. The technical specifications for the main components of the mechanical drive system have been successfully determined. This is started by studying the concept design, performing calculations, determining technical specifications, and finally defining the main components. From the evaluation, some components were decided: a stepper motor PK264A1-SG10, needle bearing NKI-10/20, spiral tube in SS316-1/8'' with 120 mm in diameter, rubber-based belts with a width of 20 mm, and aluminium drum with a diameter of 100 mm. Not all components could be identified in detail, especially for the components that do not exist in the market place and have to be created ourself. Since the main components have been identified, the detailed design step of the mechanical drive systems for the isotope source can be performed. (author)

  1. Development of a wear-resistant flux cored wire of Fe-C-Si-Mn-Cr-Ni-Mo-V system for deposit welding of mining equipment parts

    Science.gov (United States)

    Osetkovsky, I. V.; Kozyrev, N. A.; Kryukov, R. E.; Usoltsev, A. A.; Gusev, A. I.

    2017-09-01

    The effect of introduction of cobalt in the charge of the flux cored wire of Fe-C-Si-Mn-Cr-Ni-Mo-V system operating under abrasive and abrasive-shock loads is studied. In the laboratory conditions samples of flux cored wires were made, deposition was performed, the effect of cobalt on the hardness and the degree of wear was evaluated, metallographic studies were carried out. The influence of cobalt introduced into the charge of the flux cored wire of Fe-C-Si-Mn-Cr-Ni-Mo-V system on the structure, nature of nonmetallic inclusions, hardness and wear resistance of the weld metal was studied. In the laboratory conditions samples flux cored wire were made using appropriate powdered materials. As a carbon-fluorine-containing material dust from gas cleaning units of aluminum production was used. In the course of the study the chemical composition of the weld metal was determined, metallographic analysis was performed, mechanical properties were determined. As a result of the metallographic analysis the size of the former austenite grain, martensite dispersion in the structure of the weld metal, the level of contamination with its nonmetallic inclusions were established.

  2. Quantifying streambank erosion: a comparative study using an unmanned aerial system (UAS) and a terrestrial laser scanner

    Science.gov (United States)

    Rizzo, D.; Hamshaw, S. D.; Dewoolkar, M.; ONeil-Dunne, J.; Frolik, J.; Bryce, T. G.; Waldron, A. Y.

    2015-12-01

    Streambank erosion is a common non-point source contributing to suspended sediment and nutrient loading of waterways, and recently has been estimated to account for 30-80% of sediment loading into receiving waters. There is interest in developing reliable methods to quantify bank erosion in watersheds, so effective management strategies can be devised. However, current methods can be either cost prohibitive or unreliable. Direct measurement approaches (surveys and erosion pins) are labor intensive and yield site-specific measurements that are limited for extrapolation to larger scales. Similar issues arise with analytical methods such as slope stability analysis, which require material parameters that are resource intensive to determine. Newer approaches such as use of aerial LiDAR data have proved effective for watershed level assessment, but come with long turnaround times and high cost. Terrestrial laser scanning (TLS) is also effective and offers high accuracy, however collection over large areas is impractical and post-processing is labor intensive. New technology in the form of unmanned aerial systems (UAS) has the potential to significantly enhance the ability to monitor channel migration and quantify bank erosion at variable scales. In this study, 20 km of the Mad and Winooski Rivers in Vermont were flown using a senseFly eBee UAS. Flights were made in spring and fall 2015 in leaf-off conditions with selected portions also flown after large storms in the summer. Change in bank profiles between spring and fall flights provide a comprehensive estimate of bank erosion along the study reaches. Six sites with varying bank heights, erosion sensitivity, and vegetation conditions were selected for simultaneous surveying using a TLS. Point cloud data from both the TLS and UAS were compared to assess the accuracy of the UAS for capturing the bank profile. Changes in bank cross-sections and in volumes calculated from 3D digital surface models were used to compare the

  3. Three-Dimensional Static Articulation Accuracy of Virtual Models-Part II: Effect of Model Scanner-CAD Systems and Articulation Method.

    Science.gov (United States)

    Yee, Sophia Hui Xin; Esguerra, Roxanna Jean; Chew, Amelia Anya Qin'An; Wong, Keng Mun; Tan, Keson Beng Choon

    2018-02-01

    Accurate maxillomandibular relationship transfer is important for CAD/CAM prostheses. This study compared the 3D-accuracy of virtual model static articulation in three laboratory scanner-CAD systems (Ceramill Map400 [AG], inEos X5 [SIR], Scanner S600 Arti [ZKN]) using two virtual articulation methods: mounted models (MO), interocclusal record (IR). The master model simulated a single crown opposing a 3-unit fixed partial denture. Reference values were obtained by measuring interarch and interocclusal reference features with a coordinate measuring machine (CMM). MO group stone casts were articulator-mounted with acrylic resin bite registrations while IR group casts were hand-articulated with poly(vinyl siloxane) bite registrations. Five test model sets were scanned and articulated virtually with each system (6 test groups, 15 data sets). STL files of the virtual models were measured with CMM software. dR R , dR C , and dR L , represented interarch global distortions at right, central, and left sides, respectively, while dR M , dX M , dY M , and dZ M represented interocclusal global and linear distortions between preparations. Mean interarch 3D distortion ranged from -348.7 to 192.2 μm for dR R , -86.3 to 44.1 μm for dR C , and -168.1 to 4.4 μm for dR L . Mean interocclusal distortion ranged from -257.2 to -85.2 μm for dR M , -285.7 to 183.9 μm for dX M , -100.5 to 114.8 μm for dY M , and -269.1 to -50.6 μm for dZ M . ANOVA showed that articulation method had significant effect on dR R and dX M , while system had a significant effect on dR R , dR C , dR L , dR M , and dZ M . There were significant differences between 6 test groups for dR R, dR L dX M , and dZ M . dR R and dX M were significantly greater in AG-IR, and this was significantly different from SIR-IR, ZKN-IR, and all MO groups. Interarch and interocclusal distances increased in MO groups, while they decreased in IR groups. AG-IR had the greatest interarch distortion as well as interocclusal superior

  4. Stretched Wire Mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, Gordon; /SLAC

    2005-09-06

    Stretched wires are beginning to play an important role in the alignment of accelerators and synchrotron light sources. Stretched wires are proposed for the alignment of the 130 meter long LCLS undulator. Wire position technology has reached sub-micron resolution yet analyses of perturbations to wire straightness are hard to find. This paper considers possible deviations of stretched wire from the simple 2-dimensional catenary form.

  5. Automated air-void system characterization of hardened concrete: Helping computers to count air-voids like people count air-voids---Methods for flatbed scanner calibration

    Science.gov (United States)

    Peterson, Karl

    Since the discovery in the late 1930s that air entrainment can improve the durability of concrete, it has been important for people to know the quantity, spacial distribution, and size distribution of the air-voids in their concrete mixes in order to ensure a durable final product. The task of air-void system characterization has fallen on the microscopist, who, according to a standard test method laid forth by the American Society of Testing and Materials, must meticulously count or measure about a thousand air-voids per sample as exposed on a cut and polished cross-section of concrete. The equipment used to perform this task has traditionally included a stereomicroscope, a mechanical stage, and a tally counter. Over the past 30 years, with the availability of computers and digital imaging, automated methods have been introduced to perform the same task, but using the same basic equipment. The method described here replaces the microscope and mechanical stage with an ordinary flatbed desktop scanner, and replaces the microscopist and tally counter with a personal computer; two pieces of equipment much more readily available than a microscope with a mechanical stage, and certainly easier to find than a person willing to sit for extended periods of time counting air-voids. Most laboratories that perform air-void system characterization typically have cabinets full of prepared samples with corresponding results from manual operators. Proponents of automated methods often take advantage of this fact by analyzing the same samples and comparing the results. A similar iterative approach is described here where scanned images collected from a significant number of samples are analyzed, the results compared to those of the manual operator, and the settings optimized to best approximate the results of the manual operator. The results of this calibration procedure are compared to an alternative calibration procedure based on the more rigorous digital image accuracy

  6. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  7. The cobalt-60 container scanner

    International Nuclear Information System (INIS)

    Jigang, A.; Liye, Z.; Yisi, L.; Haifeng, W.; Zhifang, W.; Liqiang, W.; Yuanshi, Z.; Xincheng, X.; Furong, L.; Baozeng, G.; Chunfa, S.

    1997-01-01

    The Institute of Nuclear Energy Technology (INET) has successfully designed and constructed a container (cargo) scanner, which uses cobalt-60 of 100-300 Ci as radiation source. The following performances of the Cobalt-60 container scanner have been achieved at INET: a) IQI (Image Quality Indicator) - 2.5% behind 100 mm of steel; b) CI (Contrast Indicator) - 0.7% behind 100 mm of steel; c) SP (Steel Penetration) - 240 mm of steel; d) Maximum Dose per Scanning - 0.02mGy; e) Throughput - twenty 40-foot containers per hour. These performances are equal or similar to those of the accelerator scanners. Besides these nice enough inspection properties, the Cobalt-60 scanner possesses many other special features which are better than accelerator scanners: a) cheap price - it will be only or two tenths of the accelerator scanner's; b) low radiation intensity - the radiation protection problem is much easier to solve and a lot of money can be saved on the radiation shielding building; c) much smaller area for installation and operation; d) simple operation and convenient maintenance; e) high reliability and stability. The Cobalt-60 container (or cargo) scanner is satisfied for boundary customs, seaports, airports and railway stations etc. Because of the nice special features said above, it is more suitable to be applied widely. Its high properties and low price will make it have much better application prospects

  8. Comparison of Tension-Band Wiring With the Cable Pin System in Patella Fractures: A Randomized Prospective Study.

    Science.gov (United States)

    Tian, Qing-xian; Hai, Yong; Du, Xin-ru; Xu, Zi-yu; Lu, Tie; Shan, Lei; Liu, Yang; Zhou, Jun-lin

    2015-12-01

    To compare the outcome of tension-band wiring (TBW) with the cable pin system (CPS) for transverse fractures of the patella. Randomized prospective study. Academic Level I trauma center. From February 2008 to December 2011, 73 consecutive patients with transverse fractures of the patella were prospectively enrolled in this study. The patients were randomly divided into 2 groups: one group was treated using the CPS, and the other group was treated using the modified TBW. The clinical outcome assessment included analyses of the radiographic images, the modified Hospital for Special Surgery scoring system, and complications. The follow-up time ranged from 12 to 29 months. All fractures healed, with a union rate of 100%. The fracture healing time was significantly shorter in the CPS group (8.51 ± 2.59 weeks, n = 34) compared with the TBW group (11.79 ± 3.04 weeks, n = 39). Postoperative complications in the CPS and TBW groups were observed in 1 and 9 patients, respectively, a difference that was statistically significant. The mean Hospital for Special Surgery score for the CPS group (90.53 ± 5.19 points) was significantly higher than that for the TBW group (81.36 ± 12.71 points). The CPS is a viable option for transverse fractures of the patella and is associated with a shorter healing time, fewer complications, and better function than TBW. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  9. Development of real-time monitoring system using wired and wireless networks in a full-scale ship

    Directory of Open Access Journals (Sweden)

    Bu-Geun Paik

    2010-09-01

    Full Text Available In the present study, the real-time monitoring system is developed based on the wireless sensor network (WSN and power line communication (PLC employed in the 3,000-ton-class training ship. The WSN consists of sensor nodes, router, gateway and middleware. The PLC is composed of power lines, modems, Ethernet gateway and phase-coupler. The basic tests show that the ship has rather good environments for the wired and wireless communications. The developed real-time monitoring system is applied to recognize the thermal environments of main-engine room and one cabin in the ship. The main-engine room has lots of heat sources and needs careful monitoring to satisfy safe operation condition or detect any human errors beforehand. The monitoring is performed in two regions near the turbocharger and cascade tank, considered as heat sources. The cabin on the second deck is selected to monitor the thermal environments because it is close to the heat source of main engine. The monitoring results of the cabin show the thermal environment is varied by the human activity. The real-time monitoring for the thermal environment would be useful for the planning of the ventilation strategy based on the traces of the human activity against inconvenient thermal environments as well as the recognizing the temperature itself in each cabin.

  10. Design and Development of Embedded System for the Measurement of Thermal Conductivity of Liquids by Transient Hot Wire Method

    Directory of Open Access Journals (Sweden)

    Nagamani GOSALA

    2011-06-01

    Full Text Available Thermal conductivity of polymers is an important property for both polymer applications and processing industry. The successful application of thermal insulating fluids in the last several years has demonstrated that such fluids can effectively control the heat loss. Understanding and controlling the thermal environment for oilfield operations has been a concern and research topic. As a consequence of this trend, there is huge demand for new methods of instrumentation to evaluate the performance of material properties and characterization. The main aim of the present study is the development of hardware and software for measuring the thermal conductivity of liquids using transient hot wire method. Because of the relatively short experimental times and large amounts of parametric data involved in the measurement process, embedded control of the measurement is essential. The experimental implementation requires a suitable temperature sensing, automatic control, data acquisition, and data analysis systems accomplished using an embedded system that has been built around the ARM LPC 2103 mixed signal controller.

  11. Three-dimensional rectilinear scanner

    International Nuclear Information System (INIS)

    O'Neill, W.J.; Strange, D.R.; Miller, A.

    1976-01-01

    A rectilinear scanner for detecting radiation in a plurality of channels utilizing a collimator is described. Each of the channels receives information from a different portion of the collimator. Information separately received is separately messaged and later collated to present a common image. The information is processed by apparatus in a data processing system. This system has means for messaging analog signals corresponding to gamma radiation counts and converting such analog signals to digital signals. This system has means interfacing the digital signals into an address register that communicates directly via data busses to core memory of a central processing unit by cycle stealing and deriving clinically significant information by computation on the resultant digital data. This system has means for storing, retrieving, and displaying the resultant digital data and the resultant derivations therefrom collectively. This is done in such a manner as to allow time sequencing of the aforementioned operations such that the aforementioned operations can be interleaved on a real time basis. 13 claims, 44 figures

  12. Get Mobile – The Smartphone Brain Scanner

    DEFF Research Database (Denmark)

    Stahlhut, Carsten; Stopczynski, Arkadiusz; Petersen, Michael Kai

    This demonstration will provide live-interaction with a smartphone brain scanner consisting of a low-cost wireless 14-channel EEG headset (Emotiv Epoc) and a mobile device. With our system it is possible to perform real-time functional brain imaging on a smartphone device, including stimulus...... delivery, data acquisition, logging, brain state decoding, and 3D visualization of the cortical EEG sources. Implementation of the smartphone brain scanner is based on the Qt framework and benefits from the cross-platform support of multiple hardware platforms (smartphones, tablet devices, netbooks and PCs......) that are based on Linux operating systems. Thus our system runs on multiple platforms, including Maemo/MeeGo based smartphones, Android-based smartphones and tablet devices....

  13. Applying Performance-Controlled Systems, Fuzzy Logic, and Fly-by-Wire Controls to General Aviation

    National Research Council Canada - National Science Library

    Beringer, Dennis

    2002-01-01

    A fuzzy-logic 'performance control' system, providing envelope protection and direct command of airspeed, vertical velocity, and turn rate, was evaluated in a reconfigurable general aviation simulator...

  14. Microscopy system of atomic force based on a digital optical reading unit and a buzzer-scanner; Sistema de microscopia de fuerza atomica basada en una unidad de lectura optica digital y un escaner-zumbador

    Energy Technology Data Exchange (ETDEWEB)

    Dabirian, R.; Loza M, D. [Universidad de las Fuerzas Armadas-ESPE, Departamento de Ciencias de la Energia y Mecanica, Sangolqui (Ecuador); Wang, W. M.; Hwu, E. T., E-mail: whoand@gmail.com [Academia Sinica, Institute of Physics, Taipei, 11529 Taiwan (China)

    2015-07-01

    An astigmatic detection system (Ads) based on a compact disk/digital-versatile-disk (Cd-DVD) astigmatic optical pickup unit is presented. It can achieve a resolution better than 0.3 nm in detection of the vertical displacement and is able to detect the two-dimensional angular tilt of the object surface. Furthermore, a novel scanner design actuated by piezoelectric disk buzzers is presented. The scanner is composed of a quad-rod actuation structure and several piezoelectric disks. It can be driven directly with low-voltage and low-current sources, such as analogue outputs of a data acquisition card and enables a sufficient scanning range of up to μm. In addition, an economic, high-performance streamlined atomic force microscopy (AFM) was constructed, using the buzzer-scanner to move the sample relative to the probe, and using a Cd/DVD optical pickup unit to detect the mechanical resonance of a micro fabricated cantilever. The performance of the AFM is evaluated. The high sensitivity and high bandwidth of the detection system makes the equipment suitable for characterizing nano scale elements. An AFM using our detection system for detecting the deflection of micro fabricated cantilevers can resolve individual atomic steps on graphite surfaces. (Author)

  15. Strength of stainless steel surgical wire in various fixation modes.

    Science.gov (United States)

    Schultz, R S; Boger, J W; Dunn, H K

    1985-09-01

    Although wire is a commonly used fixation device in orthopedics, little is known about the effects of fastening methods and configurations on the strength of wiring systems. Three sizes of stainless steel surgical wire were tested in noncyclic tensile loading. Load failure levels increased with enlarging wire diameter. Fastening twists were stronger than knots or the ASIF bend technique. The failure mode for twists was untwisting. More than two twists gave no additional strength to the system. Two commercial wire tightening devices gave stronger and more reproducible twists than did ordinary pliers. The addition of a tension equalizing loop opposite the fastening loop weakened the wire system by 10%-15%. The combination of two single wire loops was stronger than a continuous double loop of wire. The results from this study are intended to help the orthopedic surgeon optimize the use of wire.

  16. Magnetic wires in MEMS and bio-medical applications

    International Nuclear Information System (INIS)

    Barbic, Mladen

    2002-01-01

    Magnetic wires of appropriate design have special features making them useful to micro-electromechanical systems and bio-medical applications. Several applications that exploit the properties of magnetic wires are reviewed including: (a) a magnetic micro-manipulation technique that utilizes integrated micro-coils and magnetic micro-wires for localized positioning of micron-sized magnetic objects, (b) integrated micro-coil/micro-wire system operating as a micro-fluidic micro-motor, (c) mechanical tweezers using magneto-static interaction between two magnetic micro-wires, and (d) ultra-high gradient magnetic separation system based on porous membranes partially filled with magnetic wires

  17. Validating a Wave-to-Wire Model for a Wave Energy Converter—Part I: The Hydraulic Transmission System

    Directory of Open Access Journals (Sweden)

    Markel Penalba

    2017-07-01

    Full Text Available Considering the full dynamics of the different conversion stages from ocean waves to the electricity grid is essential to evaluate the realistic power flow in the drive train and design accurate model-based control formulations. The power take-off system for wave energy converters (WECs is one of the essential parts of wave-to-wire (W2W models, for which hydraulic transmissions are a robust solution and offer the flexibility to design specific drive-trains for specific energy absorption requirements of different WECs. The potential hydraulic drive train topologies can be classified into two main configuration groups (constant-pressure and variable-pressure configurations, each of which uses specific components and has a particular impact on the preceding and following stages of the drive train. The present paper describes the models for both configurations, including the main nonlinear dynamics, losses and constraints. Results from the mathematical model simulations are compared against experimental results obtained from two independent test rigs, which represent the two main configurations, and high-fidelity software. Special attention is paid to the impact of friction in the hydraulic cylinder and flow and torque losses in the hydraulic motor. Results demonstrate the effectiveness of the models in reproducing experimental results, capturing friction effects and showing similar losses.

  18. A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

    Energy Technology Data Exchange (ETDEWEB)

    Yudaya Sivathanu; Jongmook Lim; Vinoo Narayanan; Seonghyeon Park

    2005-12-07

    The objective of this project is to design, fabricate and demonstrate a cost effective, multi-spectral scanner for natural gas leak detection in transmission and distribution pipelines. During the first year of the project, a laboratory version of the multi-spectral scanner was designed, fabricated, and tested at EnUrga Inc. The multi-spectral scanner was also evaluated using a blind Department of Energy study at the Rocky Mountain Oilfield Testing Center. The performance of the scanner was inconsistent during the blind study. However, most of the leaks were outside the view of the multi-spectral scanner that was developed during the first year of the project. Therefore, a definite evaluation of the capability of the scanner was not obtained. Despite the results, sufficient number of plumes was detected fully confirming the feasibility of the multi-spectral scanner. During the second year, the optical design of the scanner was changed to improve the sensitivity of the system. Laboratory tests show that the system can reliably detect small leaks (20 SCFH) at 30 to 50 feet. A prototype scanner was built and evaluated during the second year of the project. Only laboratory evaluations were completed during the second year. The laboratory evaluations show the feasibility of using the scanner to determine natural gas pipeline leaks. Further field evaluations and optimization of the scanner are required before commercialization of the scanner can be initiated.

  19. FINE-FILAMENT MAGNESIUM DIBORIDE SUPERCONDUCTOR WIRE FOR TURBOELECTRIC PROPULSION SYSTEMS, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase II proposal overcomes technology barriers for developing highly efficient all electric aircraft systems for the future, with limited impact to the...

  20. Radiation interlocks: The choice between conventional hard-wired logic and computer-based systems

    International Nuclear Information System (INIS)

    Crook, K.F.

    1986-11-01

    During the past few years, the use of computers in radiation safety systems has become more widespread. This is not surprising given the ubiquitous nature of computers in the modern technological world. But is a computer a good choice for the central logic element of a personnel safety system. Recent accidents at computer controlled medical accelerators would indicate that extreme care must be exercised if malfunctions are to be avoided. The Department of Energy has recently established a sub-committee to formulate recommendations on the use of computers in safety systems for accelerators. This paper will review the status of the committee's recommendations, and describe radiation protection interlock systems as applied to both accelerators and to irradiation facilities. Comparisons are made between the conventional relay approach and designs using computers. 6 refs., 6 figs

  1. Laser-Assisted Wire Additive Manufacturing System for the Deep Space Gateway

    Science.gov (United States)

    Foster, B. D.; Matthews, B.

    2018-02-01

    Investigation on the Deep Space Gateway will involve experiments/operations inside pressurized modules. Support for those experiments may necessitate a means to fabricate and repair required articles. This capability can be provided through an additive manufacturing (AM) system.

  2. IEE wiring regulations explained and illustrated

    CERN Document Server

    Scaddan, Brian

    2013-01-01

    The IEE Wiring Regulations Explained and Illustrated, Second Edition discusses the recommendations of the IEE Regulations for the Electrical Equipment of Buildings for the safe selection or erection of wiring installations. The book emphasizes earthing, bonding, protection, and circuit design of electrical wirings. The text reviews the fundamental requirements for safety, earthing systems, the earth fault loop impedance, and supplementary bonding. The book also describes the different types of protection, such as protection against mechanical damage, overcurrent, under voltage (which prevents

  3. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Ingebretsen, F.; Holt, K.; Skaali, B.

    1983-04-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configuration of singles and multiparameter events from 1 up to 15 ADC's in one crate

  4. Comparative evaluation of ultrasound scanner accuracy in distance measurement

    Science.gov (United States)

    Branca, F. P.; Sciuto, S. A.; Scorza, A.

    2012-10-01

    The aim of the present study is to develop and compare two different automatic methods for accuracy evaluation in ultrasound phantom measurements on B-mode images: both of them give as a result the relative error e between measured distances, performed by 14 brand new ultrasound medical scanners, and nominal distances, among nylon wires embedded in a reference test object. The first method is based on a least squares estimation, while the second one applies the mean value of the same distance evaluated at different locations in ultrasound image (same distance method). Results for both of them are proposed and explained.

  5. Structural homeostasis in the nervous system: A balancing act for wiring plasticity and stability

    Directory of Open Access Journals (Sweden)

    Jun eYin

    2015-01-01

    Full Text Available Experience-dependent modifications of neural circuits provide the cellular basis for functional adaptation and learning, while presenting significant challenges to the stability of neural networks. The nervous system copes with these perturbations through a variety of compensatory mechanisms with distinct spatial and temporal profiles. Mounting evidence suggests that structural plasticity, through modifications of the number and structure of synapses, or changes in local and long-range connectivity, might contribute to the stabilization of network activity and serve as an important component of the homeostatic regulation of the nervous system. Conceptually similar to the homeostatic regulation of synaptic strength and efficacy, homeostatic structural plasticity has a profound and lasting impact on the intrinsic excitability of the neuron and circuit properties, yet remains largely unexplored. In this review, we examine recent reports describing structural modifications associated with functional compensation in both developing and adult nervous systems, and discuss the potential role for structural homeostasis in maintaining network stability and its implications in physiological and pathological conditions of the nervous systems.

  6. Comparison between wire and wireless EEG acquisition systems based on SSVEP in an Independent-BCI.

    Science.gov (United States)

    Tello, Richard M G; Müller, Sandra M T; Bastos-Filho, Teodiano; Ferreira, Andre

    2014-01-01

    This paper presents a comparison between two different technologies of acquisition systems (BrainNet36 and Emotiv Epoc) for an Independent-BCI based on Steady-State Visual Evoked Potential (SSVEP). Two stimuli separated by a viewing angle results, obtaining the highest value for accuracy (100%) and the highest ITR (35.18 bits/min). This Independent-BCI is based on covert attention.

  7. Grid-forming VSC control in four-wire systems with unbalanced nonlinear loads

    DEFF Research Database (Denmark)

    Lliuyacca, Ruben; Mauricioa, Juan M.; Gomez-Exposito, Antonio

    2017-01-01

    A grid-forming voltage source converter (VSC) is responsible to hold voltage and frequency in autonomous operation of isolated systems. In the presence of unbalanced loads, a fourth leg is added to provide current path for neutral currents. In this paper, a novel control scheme for a four-leg VSC...... feeding unbalanced linear and nonlinear loads is proposed. The control is based on two control blocks. A main control commands the switching sequence to the three-phase VSC ensuring balanced three-phase voltage at the output; and an independent control to the fourth leg drives neutral currents that might...

  8. Neuronal Subset-Specific Migration and Axonal Wiring Mechanisms in the Developing Midbrain Dopamine System

    Directory of Open Access Journals (Sweden)

    Sara Brignani

    2017-07-01

    Full Text Available The midbrain dopamine (mDA system is involved in the control of cognitive and motor behaviors, and is associated with several psychiatric and neurodegenerative diseases. mDA neurons receive diverse afferent inputs and establish efferent connections with many brain areas. Recent studies have unveiled a high level of molecular and cellular heterogeneity within the mDA system with specific subsets of mDA neurons displaying select molecular profiles and connectivity patterns. During mDA neuron development, molecular differences between mDA neuron subsets allow the establishment of subset-specific afferent and efferent connections and functional roles. In this review, we summarize and discuss recent work defining novel mDA neuron subsets based on specific molecular signatures. Then, molecular cues are highlighted that control mDA neuron migration during embryonic development and that facilitate the formation of selective patterns of efferent connections. The review focuses largely on studies that show differences in these mechanisms between different subsets of mDA neurons and for which in vivo data is available, and is concluded by a section that discusses open questions and provides directions for further research.

  9. Systems biology in psychiatric research: from complex data sets over wiring diagrams to computer simulations.

    Science.gov (United States)

    Tretter, Felix; Gebicke-Haerter, Peter J

    2012-01-01

    The classification of psychiatric disorders has always been a problem in clinical settings. The present debate about the major systems in clinical practice, DSM-IV and ICD-10, has resulted in attempts to improve and replace those schemes by some that include more endophenotypic and molecular features. However, these disorders not only require more precise diagnostic tools, but also have to be viewed more extensively in their dynamic behaviors, which require more precise data sets related to their origins and developments. This enormous challenge in brain research has to be approached on different levels of the biological system by new methods, including improvements in electroencephalography, brain imaging, and molecular biology. All these methods entail accumulations of large data sets that become more and more difficult to interpret. In particular, on the molecular level, there is an apparent need to use highly sophisticated computer programs to tackle these problems. Evidently, only interdisciplinary work among mathematicians, physicists, biologists, and clinicians can further improve our understanding of complex diseases of the brain.

  10. Design and flight experience with a digital fly-by-wire control system using Apollo guidance system hardware on an F-8 aircraft.

    Science.gov (United States)

    Deets, D. A.; Szalai, K. J.

    1972-01-01

    This paper discusses the design and initial flight tests of the first digital fly-by-wire system to be flown in an aircraft. The system, which used components from the Apollo guidance system, was installed in an F-8 aircraft. A lunar module guidance computer is the central element in the three-axis, single-channel, multimode, digital, primary control system. An electrohydraulic triplex system providing unaugmented control of the F-8 aircraft is the only backup to the digital system. Emphasis is placed on the digital system in its role as a control augmentor, a logic processor, and a failure detector. A sampled-data design synthesis example is included to demonstrate the role of various analytical and simulation methods. The use of a digital system to implement conventional control laws was shown to be practical for flight. Logic functions coded as an integral part of the control laws were found to be advantageous. Verification of software required an extensive effort, but confidence in the software was achieved. Initial flight results showed highly successful system operation, although quantization of pilot's stick and trim were areas of minor concern from the piloting standpoint.

  11. Water Desalination with Wires

    NARCIS (Netherlands)

    Porada, S.; Sales, B.B.; Hamelers, H.V.M.; Biesheuvel, P.M.

    2012-01-01

    We show the significant potential of water desalination using a novel capacitive wire-based technology in which anode/cathode wire pairs are constructed from coating a thin porous carbon electrode layer on top of electrically conducting rods (or wires). By alternately dipping an array of electrode

  12. Performance of an improved first generation optical CT scanner for 3D dosimetry

    International Nuclear Information System (INIS)

    Qian, Xin; Wuu, Cheng-Shie; Adamovics, John

    2013-01-01

    Performance analysis of a modified 3D dosimetry optical scanner based on the first generation optical CT scanner OCTOPUS is presented. The system consists of PRESAGE™ dosimeters, the modified 3D scanner, and a new developed in-house user control panel written in Labview program which provides more flexibility to optimize mechanical control and data acquisition technique. The total scanning time has been significantly reduced from initial 8 h to ∼2 h by using the modified scanner. The functional performance of the modified scanner has been evaluated in terms of the mechanical integrity uncertainty of the data acquisition process. Optical density distribution comparison between the modified scanner, OCTOPUS and the treatment plan system has been studied. It has been demonstrated that the agreement between the modified scanner and treatment plans is comparable with that between the OCTOPUS and treatment plans. (note)

  13. A practical monitoring system for the structural safety of mega-trusses using wireless vibrating wire strain gauges.

    Science.gov (United States)

    Park, Hyo Seon; Lee, Hwan Young; Choi, Se Woon; Kim, Yousok

    2013-12-16

    Sensor technologies have been actively employed in structural health monitoring (SHM) to evaluate structural safety. To provide stable and real-time monitoring, a practical wireless sensor network system (WSNS) based on vibrating wire strain gauges (VWSGs) is proposed and applied to a building under construction. In this WSNS, the data measured from each VWSG are transmitted to the sensor node via a signal line and then transmitted to the master node through a short-range wireless communication module (operating on the Industrial, Scientific, and Medical (ISM) band). The master node also employs a long-range wireless communication module (Code Division Multiple Access-CDMA) to transmit the received data from the sensor node to a server located in a remote area, which enables a manager to examine the measured data in real time without any time or location restrictions. In this study, a total of 48 VWSGs, 14 sensor nodes, and seven master nodes were implemented to measure long-term strain variations of mega-trusses in an irregular large-scale building under construction. Based on strain data collected over a 16-month period, a quantitative evaluation of the construction process was performed to determine the aspects that exhibit the greatest influence on member behavior and to conduct a comparison with numerical simulation results. The effect of temperature stress on the structural elements was also analyzed. From these observations, the feasibility of a long-term WSNS based on VWSGs to evaluate the structural safety of an irregular building under construction was confirmed.

  14. A Practical Monitoring System for the Structural Safety of Mega-Trusses Using Wireless Vibrating Wire Strain Gauges

    Directory of Open Access Journals (Sweden)

    Hyo Seon Park

    2013-12-01

    Full Text Available Sensor technologies have been actively employed in structural health monitoring (SHM to evaluate structural safety. To provide stable and real-time monitoring, a practical wireless sensor network system (WSNS based on vibrating wire strain gauges (VWSGs is proposed and applied to a building under construction. In this WSNS, the data measured from each VWSG are transmitted to the sensor node via a signal line and then transmitted to the master node through a short-range wireless communication module (operating on the Industrial, Scientific, and Medical (ISM band. The master node also employs a long-range wireless communication module (Code Division Multiple Access—CDMA to transmit the received data from the sensor node to a server located in a remote area, which enables a manager to examine the measured data in real time without any time or location restrictions. In this study, a total of 48 VWSGs, 14 sensor nodes, and seven master nodes were implemented to measure long-term strain variations of mega-trusses in an irregular large-scale building under construction. Based on strain data collected over a 16-month period, a quantitative evaluation of the construction process was performed to determine the aspects that exhibit the greatest influence on member behavior and to conduct a comparison with numerical simulation results. The effect of temperature stress on the structural elements was also analyzed. From these observations, the feasibility of a long-term WSNS based on VWSGs to evaluate the structural safety of an irregular building under construction was confirmed.

  15. Automatic inspection of railway overhead wires

    NARCIS (Netherlands)

    Smorenburg, C.; Valkenburg, A.L.G. van

    1988-01-01

    For the Netherlands railway company a system for inspection of the degree of wear of the contact wires is being developed. With an active sensor the reflective under-surface of the overhead wire is illuminated with a laserbeam and reflected radiation is detected by fast CCD detectors. With the

  16. THE PROTECTIVE SHUTDOWN IN CASE OF THE BREAKAGE OF THE CONTACT WIRES IN THE POWER SUPPLY SYSTEM OF RAILWAY TRANSPORT

    Directory of Open Access Journals (Sweden)

    F. P. Shkrabets

    2008-02-01

    Full Text Available The type of damages is considered when the malfunction of regular tools of protection from emergency regimes in a hauling network is probable. The use of device of protecting from the break of a contact wire is offered. The charts of realization of this device under various conditions of hauling networks are presented.

  17. PS wire chamber

    CERN Document Server

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  18. Laser measuring scanners and their accuracy limits

    Science.gov (United States)

    Jablonski, Ryszard

    1993-09-01

    Scanning methods have gained the greater importance for some years now due to a short measuring time and wide range of application in flexible manufacturing processes. This paper is a summing up of the autho?s creative scientific work in the field of measuring scanners. The research conducted allowed to elaborate the optimal configurations of measuring systems based on the scanning method. An important part of the work was the analysis of a measuring scanner - as a transducer of an angle rotation into the linear displacement which resulted in obtaining its much higher accuracy and finally in working out a measuring scanner eliminating the use of an additional reference standard. The completion of the work is an attempt to determine an attainable accuracy limit of scanning measurement of both length and angle. Using a high stability deflector and a corrected scanning lens one can obtain the angle determination over 30 (or 2 mm) to an accuracy 0 (or 0 tm) when the measuring rate is 1000 Hz or the range d60 (4 mm) with accuracy 0 " (0 jim) and measurement frequency 6 Hz.

  19. Radiographic scanners and shutter mechanisms in CT scanners

    International Nuclear Information System (INIS)

    Braden, A.B.; Kuwik, J.J.; Taylor, S.K.; Covic, J.

    1981-01-01

    This patent claim relates especially to the design of a shutter mechanism in a CT scanner having a rotatable source of radiation and a series of stationary radiation detectors coplanar with the path of the source and spaced about the axis of rotation of the source, and only partially encircling the path of the source. (U.K.)

  20. Development, implementation, and characterization of a standalone embedded viscosity measurement system based on the impedance spectroscopy of a vibrating wire sensor

    International Nuclear Information System (INIS)

    Santos, José; Ramos, Pedro M; Janeiro, Fernando M

    2015-01-01

    This paper presents an embedded liquid viscosity measurement system based on a vibrating wire sensor. Although multiple viscometers based on different working principles are commercially available, there is still a market demand for a dedicated measurement system capable of performing accurate, fast measurements and requiring little or no operator training for simple systems and solution monitoring. The developed embedded system is based on a vibrating wire sensor that works by measuring the impedance response of the sensor, which depends on the viscosity and density of the liquid in which the sensor is immersed. The core of the embedded system is a digital signal processor (DSP) which controls the waveform generation and acquisitions for the measurement of the impedance frequency response. The DSP also processes the acquired waveforms and estimates the liquid viscosity. The user can interact with the measurement system through a keypad and an LCD or through a computer with a USB connection for data logging and processing. The presented system is tested on a set of viscosity standards and the estimated values are compared with the standard manufacturer specified viscosity values. A stability study of the measurement system is also performed. (paper)

  1. Development, implementation, and characterization of a standalone embedded viscosity measurement system based on the impedance spectroscopy of a vibrating wire sensor

    Science.gov (United States)

    Santos, José; Janeiro, Fernando M.; Ramos, Pedro M.

    2015-10-01

    This paper presents an embedded liquid viscosity measurement system based on a vibrating wire sensor. Although multiple viscometers based on different working principles are commercially available, there is still a market demand for a dedicated measurement system capable of performing accurate, fast measurements and requiring little or no operator training for simple systems and solution monitoring. The developed embedded system is based on a vibrating wire sensor that works by measuring the impedance response of the sensor, which depends on the viscosity and density of the liquid in which the sensor is immersed. The core of the embedded system is a digital signal processor (DSP) which controls the waveform generation and acquisitions for the measurement of the impedance frequency response. The DSP also processes the acquired waveforms and estimates the liquid viscosity. The user can interact with the measurement system through a keypad and an LCD or through a computer with a USB connection for data logging and processing. The presented system is tested on a set of viscosity standards and the estimated values are compared with the standard manufacturer specified viscosity values. A stability study of the measurement system is also performed.

  2. Projeto de aterramento para sistema monofilar com retorno pelo terra Grounding project for single wire earth return system

    Directory of Open Access Journals (Sweden)

    Humberto C Bertolo

    2011-02-01

    Full Text Available Este trabalho apresenta o projeto de aterramento elétrico para Sistema Monofilar com Retorno pela Terra (MRT, em solicitações de baixas frequências, utilizando-se o método das imagens e considerando a simplificação do método dos potenciais constantes. Simulou-se o comportamento de três diferentes configurações de aterramento: hastes em triângulo, em quadrado vazio e para nove hastes, formando uma malha com quatro quadrados. A partir da simulação obtiveram-se o valor da resistência de aterramento para cada configuração e os potenciais gerados na superfície do solo. Com base nesses resultados foi possível comparar os valores tabelados para resistências mínimas, em função da potência do transformador, aplicados para diferentes concessionárias de energia que utilizam o Sistema MRT, com os valores calculados que mantêm os potenciais no solo em níveis seguros para seres humanos e animais. Os resultados mostraram que é possível utilizar aterramentos mais simples e mais baratos, pois os gradientes de tensões no solo se mantiveram em níveis seguros.This work presents a grounding project for a Single Wire Earth Return (SWER system in low frequency applications, through the use of the image method, a simplification of the constant potential method. The responses of three different grounding configurations were simulated: electrodes in triangular format, electrodes placed in the corners of a square and nine electrodes placed in the corners of a grid with four squares. With the mentioned simulation it was possible to calculate the ground resistance and the surface voltage of each configuration. Based on these results, it was possible to compare the values for minimal resistance, depending on the power of the transformer, applied to various power utilities that use the SWER system with the values that hold the potential in the soil at safe levels for human beings and animals. Results showed that it is possible to use simpler and

  3. Health care's 100 most wired.

    Science.gov (United States)

    Solovy, A; Serb, C

    1999-02-01

    They're wired all right, and America's 100 most techno-savvy hospitals and health systems share one more thing: a commitment to using technology to link with employees, patients, suppliers, and insurers. "We want to be a health care travel agency for our community," says one chief information officer. "And we see Internet technology as a key."

  4. 46 CFR 129.340 - Cable and wiring.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cable and wiring. 129.340 Section 129.340 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.340 Cable and wiring. (a) If individual wires, rather than...

  5. Methods for CT automatic exposure control protocol translation between scanner platforms.

    Science.gov (United States)

    McKenney, Sarah E; Seibert, J Anthony; Lamba, Ramit; Boone, John M

    2014-03-01

    An imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers. Objective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner. When translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies. Protocol translation on the basis of

  6. A case study in scanner optimisation.

    Science.gov (United States)

    Dudley, N J; Gibson, N M

    2014-02-01

    Ultrasound scanner preset programmes are factory set or tailored to user requirements. Scanners may, therefore, have different settings for the same application, even on similar equipment in a single department. The aims of this study were: (1) to attempt to match the performance of two scanners, where one was preferred and (2) to assess differences between six scanners used for breast ultrasound within our organisation. The Nottingham Ultrasound Quality Assurance software was used to compare imaging performance. Images of a Gammex RMI 404GS test object were collected from six scanners, using default presets, factory presets and settings matched to a preferred scanner. Resolution, low contrast performance and high contrast performance were measured. The performance of two scanners was successfully matched, where one had been preferred. Default presets varied across the six scanners, three different presets being used. The most used preset differed in settings across the scanners, most notably in the use of different frequency modes. The factory preset was more consistent across the scanners, the main variation being in dynamic range (55-70 dB). Image comparisons showed significant differences, which were reduced or eliminated by adjustment of settings to match a reference scanner. It is possible to match scanner performance using the Nottingham Ultrasound Quality Assurance software as a verification tool. Ultrasound users should be aware that scanners may not behave in a similar fashion, even with apparently equivalent presets. It should be possible to harmonise presets by consensus amongst users.

  7. MDT WIRE TENSION MEASUREMENT USING AN ELECTROSTATIC METHOD

    CERN Document Server

    Balla, A; Esposito, B; Felici, G; Nedosekin, A; Ponzio, B; Russo, V; Spitalieri, M C

    1998-01-01

    An automated system to measure wire tension in MDT tubes is presented.The method uses electrostatic forces between wire and tube to excite mechanical oscillation around the wire harmonic resonance. A LC oscillating circuit is used to measure capacitance variation due towire oscillation. Wire tension is determined by the frequency at which the wirereaches the maximum oscillation amplitude. Both the excitation and measuring circuits are controlled by a computer.

  8. Steady-state analysis of a faulted three-phase four-wire system supplying induction motors with neutrals connected and other single-phase line-to-neutral loads

    Science.gov (United States)

    Wood, M. E.

    1980-01-01

    Four wire Wye connected ac power systems exhibit peculiar steady state fault characteristics when the fourth wire of three phase induction motors is connected. The loss of one phase of power source due to a series or shunt fault results in currents higher than anticipated on the remaining two phases. A theoretical approach to compute the fault currents and voltages is developed. A FORTRAN program is included in the appendix.

  9. Transparency in nanophotonic quantum wires

    International Nuclear Information System (INIS)

    Singh, Mahi R

    2009-01-01

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  10. Heat-shrinkable splicing materials for Class 1E wire and cable systems in nuclear power generating stations

    International Nuclear Information System (INIS)

    Handa, Katsue; Maruyama, Masahiro; Kanno, Mikio; Ohya, Shingo; Nagakawa, Seiji; Sugimori, Mikihiro

    1987-01-01

    This report describes the shapes of heat-shrinkable splicing materials (cable sleeve and breakout, and round end cap) made of polyolefine resin, their application to cable splicing, and the properties of the materials as well as of the splice using them. Particularly, the report features introduction of their properties as determined by tests under the same conditions as used in Japan in qualifying tests on wires and cables for nuclear power generating stations. The heat-shrinkable splicing materials proved to be equal in properties to flame-retardant cables for nuclear power plants when tested for oxygen index and subjected to a vertical flame test on ''insulated wire'' and a vertical tray flame test on the cable splice. It was also confirmed that Class 1E cable using these splicing materials could stand the most rigorous environmental test in Japan. Therefore they can be used for splicing Class 1E wires and cables and the splice formed with them can be regarded as Class 1E specified in IEEE Std. 383. (author)

  11. Beam tests of WPC-8 and WPC-9 prototypes of the wire pad chambers for the LHCb muon system

    CERN Document Server

    Bochin, B; Lazarev, V A; Sagidova, N; Spiridenkov, E M; Vorobiev, A P; Vorobyov, A

    2001-01-01

    Two new prototypes, WPC-8 and WPC-9, of the Wire Pad Chambers have been constructed at PNPI. The design of these double-gap wire chambers was similar to the previously tested WPC-7 prototype with one important difference: the anode wire planes were electrically independent, which allows to operate the new prototypes either in the double-gap or in the single-gap modes. The prototypes have been tested in the T11 beam at CERN, and this report presents the results of the tests. As in the previous tests, the PNPI front-end electronics based on the discrete elements was used in the read out channels. In addition, a new option of the FE electronics based on the SONY chip has been developed (SONY++) with an active adapter at the input of the chip allowing to reduce the input impedance and the width of the shaped signals. The SONY++ option was tested with the WPC-9 prototype with very satisfactory results. The performance proved to be identical to that with the PNPI FE electronics.

  12. Axial tomographic scanner

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described comprising axial tomographic means for collecting sets of data corresponding to the transmission or absorption of a number of beams of penetrating radiation through a planar slice of an object. It includes means to locate an object to be analyzed, a source and detector for directing one or more beams of penetrating radiation through the object from the source to the detector, and means to rotate (and optionally translate) the source as well as means to process the collected sets of data. Data collection, data processing, and data display can each be conducted independently of each other. An additional advantage of the system described is that the raw data (i.e., the originally collected data) are not destroyed by the data processing but instead are retained intact for further reference or use, if needed

  13. Towards plant wires

    OpenAIRE

    Adamatzky, Andrew

    2014-01-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self...

  14. Compensation strategies for PET scanners with unconventional scanner geometry

    CERN Document Server

    Gundlich, B; Oehler, M

    2006-01-01

    The small animal PET scanner ClearPET®Neuro, developed at the Forschungszentrum Julich GmbH in cooperation with the Crystal Clear Collaboration (CERN), represents scanners with an unconventional geometry: due to axial and transaxial detector gaps ClearPet®Neuro delivers inhomogeneous sinograms with missing data. When filtered backprojection (FBP) or Fourier rebinning (FORE) are applied, strong geometrical artifacts appear in the images. In this contribution we present a method that takes the geometrical sensitivity into account and converts the measured sinograms into homogeneous and complete data. By this means artifactfree images are achieved using FBP or FORE. Besides an advantageous measurement setup that reduces inhomogeneities and data gaps in the sinograms, a modification of the measured sinograms is necessary. This modification includes two steps: a geometrical normalization and corrections for missing data. To normalize the measured sinograms, computed sinograms are used that describe the geometric...

  15. Photovoltaic Wire, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  16. Photovoltaic Wire Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  17. Charpak hemispherical wire chamber

    CERN Document Server

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  18. 1998 wire development workshop proceedings

    International Nuclear Information System (INIS)

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development

  19. Nuclear fuel pin scanner

    Science.gov (United States)

    Bramblett, Richard L.; Preskitt, Charles A.

    1987-03-03

    Systems and methods for inspection of nuclear fuel pins to determine fiss loading and uniformity. The system includes infeed mechanisms which stockpile, identify and install nuclear fuel pins into an irradiator. The irradiator provides extended activation times using an approximately cylindrical arrangement of numerous fuel pins. The fuel pins can be arranged in a magazine which is rotated about a longitudinal axis of rotation. A source of activating radiation is positioned equidistant from the fuel pins along the longitudinal axis of rotation. The source of activating radiation is preferably oscillated along the axis to uniformly activate the fuel pins. A detector is provided downstream of the irradiator. The detector uses a plurality of detector elements arranged in an axial array. Each detector element inspects a segment of the fuel pin. The activated fuel pin being inspected in the detector is oscillated repeatedly over a distance equal to the spacing between adjacent detector elements, thereby multiplying the effective time available for detecting radiation emissions from the activated fuel pin.

  20. Dental impressions using 3D digital scanners: virtual becomes reality.

    Science.gov (United States)

    Birnbaum, Nathan S; Aaronson, Heidi B

    2008-10-01

    The technologies that have made the use of three-dimensional (3D) digital scanners an integral part of many industries for decades have been improved and refined for application to dentistry. Since the introduction of the first dental impressioning digital scanner in the 1980s, development engineers at a number of companies have enhanced the technologies and created in-office scanners that are increasingly user-friendly and able to produce precisely fitting dental restorations. These systems are capable of capturing 3D virtual images of tooth preparations, from which restorations may be fabricated directly (ie, CAD/CAM systems) or fabricated indirectly (ie, dedicated impression scanning systems for the creation of accurate master models). The use of these products is increasing rapidly around the world and presents a paradigm shift in the way in which dental impressions are made. Several of the leading 3D dental digital scanning systems are presented and discussed in this article.

  1. Step by Step Design of a High Order Power Filter for Three-Phase Three-Wire Grid-connected Inverter in Renewable Energy System

    OpenAIRE

    Huang, Min; Blaabjerg, Frede; Yang, Yongheng; Wu, Weimin

    2013-01-01

    Traditionally, when designing an LCL-filter, a three-phase inverter is simplified as a single-phase inverter for analysis and the output phase voltage is used to calculate the inverter-side current harmonics and to design inverter-side inductor. However, for a three-phase three-wire grid-tied system, the output current harmonics of inverter are directly affected by the output line to line voltage. Hence, this paper proposes a new method to analyze the inverter output current harmonics by usin...

  2. Applications of the scanner in osteoarticular pathology

    Energy Technology Data Exchange (ETDEWEB)

    Bard, M.; Morvan, G.; Busson, J.; Massare, C.

    1986-03-01

    The authors take stock of current applications of the scanner in osteoarticular pathology. At first (1978-1983 approximately), only the vertebral column could be studied by this technique. Now, almost all the osteoarticular system is susceptible to study. Established examples are: study of the sacrum, of the traumatized acetabulum, of the femoropatellar apparatus, and measurement of torsion in the lower limbs. New applications are: study of the back of the foot, of the patellar cartilage, of the glenoid cavity, of the bones and soft parts of the hand, three-dimensional reconstructions, scanning radiology. The authors index and analyse these new techniques.

  3. Near-field optical spectroscopy of single quantum wires

    Science.gov (United States)

    Harris, T. D.; Gershoni, D.; Grober, R. D.; Pfeiffer, L.; West, K.; Chand, N.

    1996-02-01

    Low temperature near-field scanning optical microscopy is used for spectroscopic studies of single, nanometer dimension, cleaved edge overgrown quantum wires. A direct experimental comparison between a two dimensional system and a single genuinely one dimensional quantum wire system, inaccessible to conventional far field optical spectroscopy, is enabled by the enhanced spatial resolution. We show that the photoluminescence of a single quantum wire is easily distinguished from that of the surrounding quantum well. Emission from localized centers is shown to dominate the photoluminescence from both wires and wells at low temperatures. A factor of 3 absorption enhancement for these wires compared to the wells is concluded from the photoluminescence excitation data.

  4. Hot-wire air flow meter for gasoline fuel-injection system. Calculation of air mass in cylinder during transient condition; Gasoline funsha system yo no netsusenshiki kuki ryuryokei. Kato untenji no cylinder juten kukiryo no keisan

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Y. [Hitachi Car Engineering, Ltd., Tokyo (Japan); Nishimura, Y.; Osuga, M.; Yamauchi, T. [Hitachi, Ltd., Tokyo (Japan)

    1997-10-01

    Air flow characteristics of hot-wire air flow meters for gasoline fuel-injection systems with supercharging and exhaust gas recycle during transient conditions were investigated to analyze a simple method for calculating air mass in cylinder. It was clarified that the air mass in cylinder could be calculated by compensating for the change of air mass in intake system by using aerodynamic models of intake system. 3 refs., 6 figs., 1 tab.

  5. Wire Array Photovoltaics

    Science.gov (United States)

    Turner-Evans, Dan

    Over the past five years, the cost of solar panels has dropped drastically and, in concert, the number of installed modules has risen exponentially. However, solar electricity is still more than twice as expensive as electricity from a natural gas plant. Fortunately, wire array solar cells have emerged as a promising technology for further lowering the cost of solar. Si wire array solar cells are formed with a unique, low cost growth method and use 100 times less material than conventional Si cells. The wires can be embedded in a transparent, flexible polymer to create a free-standing array that can be rolled up for easy installation in a variety of form factors. Furthermore, by incorporating multijunctions into the wire morphology, higher efficiencies can be achieved while taking advantage of the unique defect relaxation pathways afforded by the 3D wire geometry. The work in this thesis shepherded Si wires from undoped arrays to flexible, functional large area devices and laid the groundwork for multijunction wire array cells. Fabrication techniques were developed to turn intrinsic Si wires into full p-n junctions and the wires were passivated with a-Si:H and a-SiNx:H. Single wire devices yielded open circuit voltages of 600 mV and efficiencies of 9%. The arrays were then embedded in a polymer and contacted with a transparent, flexible, Ni nanoparticle and Ag nanowire top contact. The contact connected >99% of the wires in parallel and yielded flexible, substrate free solar cells featuring hundreds of thousands of wires. Building on the success of the Si wire arrays, GaP was epitaxially grown on the material to create heterostructures for photoelectrochemistry. These cells were limited by low absorption in the GaP due to its indirect bandgap, and poor current collection due to a diffusion length of only 80 nm. However, GaAsP on SiGe offers a superior combination of materials, and wire architectures based on these semiconductors were investigated for multijunction

  6. A high speed X-ray computed tomography scanner for multipurpose flow visualization and measurement

    International Nuclear Information System (INIS)

    Hori, K.; Kawanishi, K.; Hamamura, H.; Ochi, M.; Akai, M.

    2004-01-01

    The development of a high-speed X-ray computed tomography (CT) scanner has been performed in this study. The object of interest is in a transient or unsettled state, which makes the conventional CT scanner inappropriate. This X-ray CT system uses the concept of electronic switching of electron beams for X-ray generation to increase scanning speed. A continuous operation X-ray CT scanner sampling at about 4 milliseconds scanning rate has already been developed and applied for air-water two-phase flow measurement. The feasibility and the excellent performance of this CT scanner system are demonstrated and confirmed. (author)

  7. Evaluation of scanners for C-scan imaging in nondestructive inspection of aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Gieske, J.H.

    1994-04-01

    The goal of this project was to produce a document that contains information on the usability and performance of commercially available, fieldable, and portable scanner systems as they apply to aircraft NDI inspections. In particular, the scanners are used to generate images of eddy current, ultrasonic, or bond tester inspection data. The scanner designs include manual scanners, semiautomated scanners, and fully automated scanners. A brief description of the functionality of each scanner type, a sketch, and a fist of the companies that support the particular design are provided. Vendors of each scanner type provided hands-on demonstrations of their equipment on real aircraft samples in the FAA Aging Aircraft Nondestructive Inspection Validation Center (AANC) in Albuquerque, NM. From evaluations recorded during the demonstrations, a matrix of scanner features and factors and ranking of the capabilities and limitations of the design, portability, articulation, performance, usability, and computer hardware/software was constructed to provide a quick reference for comparing the different scanner types. Illustrations of C-scan images obtained during the demonstration are shown.

  8. Vacuum Attachment for XRF Scanner

    Science.gov (United States)

    Schramm, Harry F.; Kaiser, Bruce

    2005-01-01

    Vacuum apparatuses have been developed for increasing the range of elements that can be identified by use of x-ray fluorescent (XRF) scanners of the type mentioned in the two immediately preceding articles. As a consequence of the underlying physical principles, in the presence of air, such an XRF scanner is limited to analysis of chlorine and elements of greater atomic number. When the XRF scanner is operated in a vacuum, it extends the range of analysis to lower atomic numbers - even as far as aluminum and sodium. Hence, more elements will be available for use in XRF labeling of objects as discussed in the two preceding articles. The added benefits of the extended capabilities also have other uses for NASA. Detection of elements of low atomic number is of high interest to the aerospace community. High-strength aluminum alloys will be easily analyzed for composition. Silicon, a major contaminant in certain processes, will be detectable before the process is begun, possibly eliminating weld or adhesion problems. Exotic alloys will be evaluated for composition prior to being placed in service where lives depend on them. And in the less glamorous applications, such as bolts and fasteners, substandard products and counterfeit items will be evaluated at the receiving function and never allowed to enter the operation

  9. Development of instrumentation for fuel pin scanner

    International Nuclear Information System (INIS)

    Saisubalakshmi, D.; Parthasarathy, R.; Brahmaji Rao, J.S.; Senthilvadivu, E.; Seshadreesan, N.P.

    2011-01-01

    A study is being carried out using a surrogate vibro-packed fuel pin with micro-spheres of two different sizes to get the density distribution by gamma transmission technique. A shielded (with 2 mm slit of ∼ 2''SS collimator) LaBr scintillation detector is used as the detector system. A strong 137 Cs source is used as the source. The source strength as it is transmitted through the fuel pin is measured by the scintillation detector. The entire length of the fuel pin is gradually moved up from one end to other end and the detector is allowed to continuously examine the transmission profile of the fuel pin. The instrumentation for the fuel pin scanner has been developed and is integrated with the system. The instrumentation includes microcontroller based motor control system and customized detector pulse counting systems. The systems are interfaced to a computer through serial communication. (author)

  10. Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires.

    Science.gov (United States)

    Tada, Yoshifumi; Hayakawa, Tohru; Nakamura, Yoshiki

    2017-08-09

    Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 × 0.022 in² and 0.019 × 0.025 in² (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bending properties were evaluated in a modified three-point bending system for orthodontics. The static friction between the orthodontic wire and the bracket was also measured. The load-deflection curves were similar among Ni-Ti and PEEK wires, except for 16PEEK with slot-lid ligation. The bending force of 19-25PEEK wire was comparable with that of Ni-Ti wire. 19-25PEEK showed the highest load at the deflection of 1500 μm ( p 0.05). No significant difference was seen in static friction between all three PEEK wires and Ni-Ti wire ( p > 0.05). It is suggested that 19-25PEEK will be applicable for orthodontic treatment with the use of slot-lid ligation.

  11. Automating wiring formboard design

    NARCIS (Netherlands)

    Van den Berg, T.

    2013-01-01

    Increase in aircraft wiring complexity call for manufacturing design improvements to reduce cost and lead-time. To achieve such improvements, a joint research project was performed by the Flight Performance and Propulsion (FPP) group and Fokker Elmo BV, the second largest aircraft wiring harness

  12. Localization of a mobile laser scanner via dimensional reduction

    Science.gov (United States)

    Lehtola, Ville V.; Virtanen, Juho-Pekka; Vaaja, Matti T.; Hyyppä, Hannu; Nüchter, Andreas

    2016-11-01

    We extend the concept of intrinsic localization from a theoretical one-dimensional (1D) solution onto a 2D manifold that is embedded in a 3D space, and then recover the full six degrees of freedom for a mobile laser scanner with a simultaneous localization and mapping algorithm (SLAM). By intrinsic localization, we mean that no reference coordinate system, such as global navigation satellite system (GNSS), nor inertial measurement unit (IMU) are used. Experiments are conducted with a 2D laser scanner mounted on a rolling prototype platform, VILMA. The concept offers potential in being extendable to other wheeled platforms.

  13. A new orthodontic force system for moment control utilizing the flexibility of common wires: Evaluation of the effect of contractile force and hook length.

    Science.gov (United States)

    Lai, Wei-Jen; Midorikawa, Yoshiyuki; Kanno, Zuisei; Takemura, Hiroshi; Suga, Kazuhiro; Soga, Kohei; Ono, Takashi; Uo, Motohiro

    2018-01-01

    The application of an appropriate force system is indispensable for successful orthodontic treatments. Second-order moment control is especially important in many clinical situations, so we developed a new force system composed of a straight orthodontic wire and two crimpable hooks of different lengths to produce the second-order moment. The objective of this study was to evaluate this new force system and determine an optimum condition that could be used in clinics. We built a premolar extraction model with two teeth according to the concept of a modified orthodontic simulator. This system was activated by applying contractile force from two hooks that generated second-order moment and force. The experimental device incorporated two sensors, and forces and moments were measured along six axes. We changed the contractile force and hook length to elucidate their effects. Three types of commercial wires were tested. The second-order moment was greater on the longer hook side of the model. Vertical force balanced the difference in moments between the two teeth. Greater contractile force generated a greater second-order moment, which reached a limit of 150 g. Excessive contractile force induced more undesired reactions in the other direction. Longer hooks induced greater moment generation, reaching their limit at 10 mm in length. The system acted similar to an off-center V-bend and can be applied in clinical practice as an unconventional loop design. We suggest that this force system has the potential for second-order moment control in clinical applications. Copyright © 2017. Published by Elsevier B.V.

  14. A clinical molecular scanner: the Melanie project.

    Science.gov (United States)

    Hochstrasser, D F; Appel, R D; Vargas, R; Perrier, R; Vurlod, J F; Ravier, F; Pasquali, C; Funk, M; Pellegrini, C; Muller, A F

    1991-01-01

    We developed an expert system to analyze and interpret protein maps. This system, Melanie (medical electrophoresis analysis interactive expert), can distinguish between normal and cirrhotic liver and identify various types of cancer on the basis of protein patterns in biopsy specimens. Our findings suggest that some diseases associated with toxic compounds or modifications of the human genome can be diagnosed by expert systems that analyze protein maps. The combination of protein mapping and computer analysis could result in a clinically useful "molecular scanner". The massive amount of information analyzed and stored in such studies requires new strategies, including centralized databases and image transmission over networks. Increased understanding of protein expression and regulation will enhance the importance of the human genome project in medicine and biology.

  15. Characterization of a Large, Low-Cost 3D Scanner

    Directory of Open Access Journals (Sweden)

    Jeremy Straub

    2015-01-01

    Full Text Available Imagery-based 3D scanning can be performed by scanners with multiple form factors, ranging from small and inexpensive scanners requiring manual movement around a stationary object to large freestanding (nearly instantaneous units. Small mobile units are problematic for use in scanning living creatures, which may be unwilling or unable to (or for the very young and animals, unaware of the need to hold a fixed position for an extended period of time. Alternately, very high cost scanners that can capture a complete scan within a few seconds are available, but they are cost prohibitive for some applications. This paper seeks to assess the performance of a large, low-cost 3D scanner, presented in prior work, which is able to concurrently capture imagery from all around an object. It provides the capabilities of the large, freestanding units at a price point akin to the smaller, mobile ones. This allows access to 3D scanning technology (particularly for applications requiring instantaneous imaging at a lower cost. Problematically, prior analysis of the scanner’s performance was extremely limited. This paper characterizes the efficacy of the scanner for scanning both inanimate objects and humans. Given the importance of lighting to visible light scanning systems, the scanner’s performance under multiple lighting configurations is evaluated, characterizing its sensitivity to lighting design.

  16. Thermosonic wire bonding of IC devices using palladium wire

    International Nuclear Information System (INIS)

    Shze, J.H.; Poh, M.T.; Tan, R.M.

    1996-01-01

    The feasibility of replacing gold wire by palladium wire in thermosonic wire bonding of CMOS and bipolar devices are studied in terms of the manufacturability, physical, electrical and assembly performance. The results that palladium wire is a viable option for bonding the bipolar devices but not the CMOS devices

  17. Present Status and Future Perspective of Bismuth-Based High-Temperature Superconducting Wires Realizing Application Systems

    Science.gov (United States)

    Sato, Ken-ichi; Kobayashi, Shin-ichi; Nakashima, Takayoshi

    2012-01-01

    Among a series of high-temperature superconducting materials that have been discovered to date, (Bi,Pb)2Sr2Ca2Cu3O10-x is the best candidate for superconducting wires that are long with commercial productivity, and critical current performance. In particular, the controlled overpressure (CT-OP) sintering technique gave us a 100% density of (Bi,Pb)2Sr2Ca2Cu3O10-x portion, which leads to robustness, increase in critical current, and mechanical tolerance. Many application prototypes are already verified and are being evaluated worldwide. Current leads for large magnets and magnetic billet heaters are already commercial products. Commercial applications for power cables, motors for ship propulsion and electric vehicles, and many kinds of magnets are promising in the near future.

  18. Step potential in single wire earth return system; Potencial de passo em sistema monofilar com retorno por terra

    Energy Technology Data Exchange (ETDEWEB)

    Silva Junior, Amancio R.; Caminha Junior, Isidoro C.; Watabe, Celso F.; Romero, Andrea G. [Mato Grosso do Sul Univ., Campo Grande, MS (Brazil). Dept. de Engenharia Eletrica

    1997-12-31

    It was built on the dependence of the campus of Mato Grosso do Sul University, an experimental line single wire earth return (SWER). It was realized, weekly, during the years of 1996, measurement of step potential, with a unique landing (primary only) and, primary and secondary connected. It was verified that: the most critical measurement happened when the earth presented superficial resistivity of 455,31 {Omega} x m, the highest step potential for not causing ventricular fibrillation was 249,93 V, needing a short circuit currents of 11,07 kA, the primary and secondary resistance earth presented values 42 {Omega} and 77 {Omega} respectively. There was no significant alteration when was used only the primary landing. (author) 11 refs., 2 figs.

  19. A 3D airborne ultrasound scanner

    Science.gov (United States)

    Capineri, L.; Masotti, L.; Rocchi, S.

    1998-06-01

    This work investigates the feasibility of an ultrasound scanner designed to reconstruct three-dimensional profiles of objects in air. There are many industrial applications in which it is important to obtain quickly and accurately the digital reconstruction of solid objects with contactless methods. The final aim of this project was the profile reconstruction of shoe lasts in order to eliminate the mechanical tracers from the reproduction process of shoe prototypes. The feasibility of an ultrasonic scanner was investigated in laboratory conditions on wooden test objects with axial symmetry. A bistatic system based on five airborne polyvinylidenedifluoride (PVDF) transducers was mechanically moved to emulate a cylindrical array transducer that can host objects of maximum width and height 20 cm and 40 cm respectively. The object reconstruction was based on a simplified version of the synthetic aperture focusing technique (SAFT): the time of flight (TOF) of the first in time echo for each receiving transducer was taken into account, a coarse spatial sampling of the ultrasonic field reflected on the array transducer was delivered and the reconstruction algorithm was based on the ellipsoidal backprojection. Measurements on a wooden cone section provided submillimetre accuracy in a controlled environment.

  20. Cryogenic Pressure Seal for Wires

    Science.gov (United States)

    Ciana, J. J.

    1984-01-01

    High-pressure-seal formed by forcing polyurethane into space surrounding wire or cable in special fitting. Wire or cable routed through fitting then through a tightly fitting cap. Wire insulation left intact. Cap filled with sealant and forced onto the fitting: this pushes sealant into fitting so it seals wire or cable in fitting as well as in cap.

  1. Accuracy and reproducibility of the DAVID SLS-2 scanner in three-dimensional facial imaging

    DEFF Research Database (Denmark)

    Secher, Jesper Jared; Darvann, Tron Andre; Pinholt, Else Marie

    2017-01-01

    PURPOSE: A prospective study was performed to test the accuracy and reproducibility of the DAVID-SLS-2 scanner (SLS-2) [DAVID Vision Systems GmbH], compared to the validated 3dMDtrio scanner (3dMD) [3dMD, LLC, Atlanta, GA, USA]. MATERIALS AND METHODS: The accuracy of the SLS-2 was determined thro...

  2. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  3. Robotic Prostate Biopsy in Closed MRI Scanner

    National Research Council Canada - National Science Library

    Fischer, Gregory

    2008-01-01

    .... This work enables prostate brachytherapy and biopsy procedures in standard high-field diagnostic MRI scanners through the development of a robotic needle placement device specifically designed...

  4. A new design of wire locators for drift tubes

    CERN Document Server

    Ilgner, C

    2004-01-01

    Every position-sensitive wire detector needs to solve the problem of wire positioning with a defined accuracy all over its sensitive volume. In particular, thin-walled drift tubes ("straws"), which are currently being attached to large detector units of several tens of square meters of surface, need to be equipped with wire locators along their signal wires. A wire locator has been developed together with an insertion device, especially for medium-sized drift tube systems, which significantly reduces the production time and avoids the danger of applying epoxy glue to the signal wire. The wire locator is being inserted in one single time-saving production step together with the signal wire itself. The proposed design is being compared to the rigid wire locators in use in the COMPASS straw tracking system at CERN. The investigation comprises both wire- centering capability and influence on the efficiency of adjacent detector regions, demonstrating the competitive performance of the proposed new system. Its suff...

  5. Needleless electrospinning with twisted wire spinneret

    International Nuclear Information System (INIS)

    Holopainen, Jani; Penttinen, Toni; Santala, Eero; Ritala, Mikko

    2015-01-01

    A needleless electrospinning setup named ‘Needleless Twisted Wire Electrospinning’ was developed. The polymer solution is electrospun from the surface of a twisted wire set to a high voltage and collected on a cylindrical collector around the wire. Multiple Taylor cones are simultaneously self-formed on the downward flowing solution. The system is robust and simple with no moving parts aside from the syringe pump used to transport the solution to the top of the wire. The structure and process parameters of the setup and the results on the preparation of polyvinyl pyrrolidone (PVP), hydroxyapatite (HA) and bioglass fibers with the setup are presented. PVP fiber sheets with areas of 40 × 120 cm 2 and masses up to 1.15 g were prepared. High production rates of 5.23 g h −1 and 1.40 g h −1 were achieved for PVP and HA respectively. The major limiting factor of the setup is drying of the polymer solution on the wire during the electrospinning process which will eventually force to interrupt the process for cleaning of the wire. Possible solutions to this problem and other ways to develop the setup are discussed. The presented system provides a simple way to increase the production rate and area of fiber sheet as compared with the conventional needle electrospinning. (paper)

  6. Multifunctional sensor systems for future steer-by-wire and air conditioning systems. Final report; Multifunktionale Sensorsysteme fuer zukuenftige 'Steer-by-wire'- und Kfz-Klimasysteme (MuSe). Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    A two-sensitivity pressure sensor was developed at EADS Deutschland GmbH, the former DC, with high resolution at low pressure, good results at high pressure, and an integrated self-test. Functional tests were carried out, and the technological and technical fundamentals for marketable sensors were developed. In a sub-project, a sensor for pressure testing of CO2-filled air conditioners was developed. This application had specific problems, i.e. higher temperatures and pressures (working temperatures of -40 to 190 C centigrade, working pressure of 200 bar, burst pressure of 300 bar), and separation of media without additional separating media. A sensor concept for this application was developed at TU Berlin University. (orig.) [German] Im Rahmen des Teilprojektes 'Druckmessung in elektrohydraulischen 'X by Wire' - Systemen' wurde ein Zwei-Empfindlichkeitsbereichs Drucksensor entwickelt. Die Haupteigenschaften des Sensors sind eine hohe Aufloesung im niedrigen Druckbereich, die Moeglichkeit auch grosse Druecke zu messen und ein eingebauter Selbsttest. Bei der EADS Deutschland GmbH (ehem. DC) wurde sowohl das Konzept als auch die Simulationsmodelle eines Sensors entwickelt, der in der Lage ist Druecke bis 200 bar zu messen und dabei eine hohe Aufloesung im Bereich von 0... 30 bar liefert. Der Funktionsnachweis fuer den Drucksensordemonstrator wurde erbracht und es wurden technologische und technische Grundlagen fuer Sensorsystemloesungen geschaffen, die eine Umsetzung wesentlich beschleunigen und Marktchance der KMUs erhoehen. Im Rahmen des Teilprojektes 'HT-Druckmesszelle fuer Kfz-Klimasysteme' wurde ein Sensor fuer die Druckmessung in CO{sub 2}-befuellten Klimaanlagen entwickelt. Die Hauptanforderungen an einen solchen Sensor sind einerseits der erhoehte Temperatur- und Druckbereich (-40... 190 C Arbeitstemperaturbereich, 200 bar Arbeitsdruck, 300 bar Berstdruck) sowie die ohne zusaetzliche Trennmedien zu erreichende Medientrennung. An

  7. Development of Estimation Force Feedback Torque Control Algorithm for Driver Steering Feel in Vehicle Steer by Wire System: Hardware in the Loop

    Directory of Open Access Journals (Sweden)

    Sheikh Muhammad Hafiz Fahami

    2015-01-01

    Full Text Available In conventional steering system, a feedback torque is produced from the contact between tire and road surface and its flows through mechanical column shaft directly to driver. This allows the driver to sense the steering feel during driving. However, in steer by wire (SBW system, the elimination of the mechanical column shaft requires the system to generate the feedback torque which should produce similar performance with conventional steering system. Therefore, this paper proposes a control algorithm to create the force feedback torque for SBW system. The direct current measurement approach is used to estimate torque at the steering wheel and front axle motor as elements to the feedback torque, while, adding the compensation torque for a realistic feedback torque. The gain scheduling with a linear quadratic regulator controller is used to control the feedback torque and to vary a steering feel gain. To investigate the effectiveness of the proposed algorithm, a real-time hardware in the loop (HIL methodology is developed using Matlab XPC target toolbox. The results show that the proposed algorithm is able to generate the feedback torque similar to EPS steering system. Furthermore, the compensation torque is able to improve the steering feel and stabilize the system.

  8. Heat Transfer Analysis in Wire Bundles for Aerospace Vehicles

    Science.gov (United States)

    Rickman, S. L.; Iamello, C. J.

    2016-01-01

    Design of wiring for aerospace vehicles relies on an understanding of "ampacity" which refers to the current carrying capacity of wires, either, individually or in wire bundles. Designers rely on standards to derate allowable current flow to prevent exceedance of wire temperature limits due to resistive heat dissipation within the wires or wire bundles. These standards often add considerable margin and are based on empirical data. Commercial providers are taking an aggressive approach to wire sizing which challenges the conventional wisdom of the established standards. Thermal modelling of wire bundles may offer significant mass reduction in a system if the technique can be generalized to produce reliable temperature predictions for arbitrary bundle configurations. Thermal analysis has been applied to the problem of wire bundles wherein any or all of the wires within the bundle may carry current. Wire bundles present analytical challenges because the heat transfer path from conductors internal to the bundle is tortuous, relying on internal radiation and thermal interface conductance to move the heat from within the bundle to the external jacket where it can be carried away by convective and radiative heat transfer. The problem is further complicated by the dependence of wire electrical resistivity on temperature. Reduced heat transfer out of the bundle leads to higher conductor temperatures and, hence, increased resistive heat dissipation. Development of a generalized wire bundle thermal model is presented and compared with test data. The steady state heat balance for a single wire is derived and extended to the bundle configuration. The generalized model includes the effects of temperature varying resistance, internal radiation and thermal interface conductance, external radiation and temperature varying convective relief from the free surface. The sensitivity of the response to uncertainties in key model parameters is explored using Monte Carlo analysis.

  9. Pin Wire Coating Trip Report

    International Nuclear Information System (INIS)

    Spellman, G P

    2004-01-01

    A meeting to discuss the current pin wire coating problems was held at the Reynolds plant in Los Angeles on 2MAR04. The attendance list for Reynolds personnel is attached. there was an initial presentation which gave a brief history and the current status of pin wire coating at Reynolds. There was a presentation by Lori Primus on the requirements and issues for the coating. There was a presentation by Jim Smith of LANL on the chemistry and to some extent process development done to date. There was a long session covering what steps should be taken in the short term and, to a lesser extent, the long term. The coating currently being used is a blend of two polymers, polyethersulfone and polyparabanic acid (PPA) and some TiO2 filler. This system was accepted and put into production when the pin wire coating was outsourced to another company in 1974. When that company no longer was interested, the wire coating was brought in-house to Reynolds. At that time polyparabanic acid was actually a commercial product available from Exxon under the trade name Tradlon. However, it appears that the material used at Reynolds was synthesized locally. Also, it appears that a single large batch was synthesized in that time period and used up to 1997 when the supply ran out. The reason for the inclusion of TiO2 is not known although it does act as a rheological thickener. However, a more controlled thickening can be obtained with materials such as fumed silica. This material would have less likelihood of causing point imperfections in the coatings. Also, the mixing technique being used for all stages of the process is a relatively low shear ball mill process and the author recommends a high shear process such as a three roll paint mill, at least for the final mixing. Since solvent is added to the powder at Reynolds, it may be that they need to have the paint mill there

  10. Laser Scanner For Automatic Storage

    Science.gov (United States)

    Carvalho, Fernando D.; Correia, Bento A.; Rebordao, Jose M.; Rodrigues, F. Carvalho

    1989-01-01

    The automated magazines are beeing used at industry more and more. One of the problems related with the automation of a Store House is the identification of the products envolved. Already used for stock management, the Bar Codes allows an easy way to identify one product. Applied to automated magazines, the bar codes allows a great variety of items in a small code. In order to be used by the national producers of automated magazines, a devoted laser scanner has been develloped. The Prototype uses an He-Ne laser whose beam scans a field angle of 75 degrees at 16 Hz. The scene reflectivity is transduced by a photodiode into an electrical signal, which is then binarized. This digital signal is the input of the decodifying program. The machine is able to see barcodes and to decode the information. A parallel interface allows the comunication with the central unit, which is responsible for the management of automated magazine.

  11. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery.

    Science.gov (United States)

    Oh, You Na; Ha, Keong Jun; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won

    2015-08-01

    Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578), major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99), minor wound complications (3.6% vs. 2.0%, p=0.279), or mediastinitis (0.8% vs. 1.0%, p=1.00). Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068). The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  12. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    You Na Oh

    2015-08-01

    Full Text Available Background: Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Methods: Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Results: Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578, major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99, minor wound complications (3.6% vs. 2.0%, p=0.279, or mediastinitis (0.8% vs. 1.0%, p=1.00. Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068. Conclusion: The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  13. Computer-aided analysis of digital dental impressions obtained from intraoral and extraoral scanners.

    Science.gov (United States)

    Bohner, Lauren Oliveira Lima; De Luca Canto, Graziela; Marció, Bruno Silva; Laganá, Dalva Cruz; Sesma, Newton; Tortamano Neto, Pedro

    2017-11-01

    The internal and marginal adaptation of a computer-aided design and computer-aided manufacturing (CAD-CAM) prosthesis relies on the quality of the 3-dimensional image. The quality of imaging systems requires evaluation. The purpose of this in vitro study was to evaluate and compare the trueness of intraoral and extraoral scanners in scanning prepared teeth. Ten acrylic resin teeth to be used as a reference dataset were prepared according to standard guidelines and scanned with an industrial computed tomography system. Data were acquired with 4 scanner devices (n=10): the Trios intraoral scanner (TIS), the D250 extraoral scanner (DES), the Cerec Bluecam intraoral scanner (CBIS), and the Cerec InEosX5 extraoral scanner (CIES). For intraoral scanners, each tooth was digitized individually. Extraoral scanning was obtained from dental casts of each prepared tooth. The discrepancy between each scan and its respective reference model was obtained by deviation analysis (μm) and volume/area difference (μm). Statistical analysis was performed using linear models for repeated measurement factors test and 1-way ANOVA (α=.05). No significant differences in deviation values were found among scanners. For CBIS and CIES, the deviation was significantly higher (PDentistry. Published by Elsevier Inc. All rights reserved.

  14. Comparative Analysis of Computer Network Security Scanners

    Directory of Open Access Journals (Sweden)

    Victor Sergeevich Gorbatov

    2013-02-01

    Full Text Available The paper is devoted to the analysis of the problem of comparison of security scanners computer network. A common comprehensive assessment of security control is developed on the base of comparative analysis of data security controls. We have tested security scanners available on the market.

  15. Scanner for ultrasonic scanning of surfaces.

    NARCIS (Netherlands)

    Berkhout, A.J.; Van Hoorn, W.A.

    1991-01-01

    Abstract of EP 0453014 (A1) Scanner for scanning surfaces with ultrasonic signals, in particular surfaces of parts of the body, provided with a scanner head (5) for the transmission of ultrasonic signals and the reception of the echoes hereof. The time passed between the emission of the signal and

  16. Flexible, polymer-supported, Si wire array photoelectrodes

    Energy Technology Data Exchange (ETDEWEB)

    Spurgeon, Joshua M.; Boettcher, Shannon W.; Brunschwig, Bruce S.; Lewis, Nathan S. [California Institute of Technology, Division of Chemistry and Chemical Engineering, Pasadena, CA (United States); Kelzenberg, Michael D.; Atwater, Harry A. [California Institute of Technology, Division of Engineering and Applied Science, Pasadena, CA (United States)

    2010-08-10

    Arrays of oriented, crystalline Si wires are transferred into flexible, transparent polymer films. The polymer-supported Si wire arrays in liquid-junction photoelectrochemical cells yield current-potential behavior similar to the Si wires attached to the brittle growth substrate. These systems offer the potential for attaining high solar energy-conversion efficiencies using modest diffusion length, readily grown, crystalline Si in a flexible, processable form. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  17. A 3D-Space Vector Modulation Algorithm for Three Phase Four Wire Neutral Point Clamped Inverter Systems as Power Quality Compensator

    Directory of Open Access Journals (Sweden)

    Palanisamy Ramasamy

    2017-11-01

    Full Text Available A Unified Power Quality Conditioner (UPQC is designed using a Neutral Point Clamped (NPC multilevel inverter to improve the power quality. When designed for high/medium voltage and power applications, the voltage stress across the switches and harmonic content in the output voltage are increased. A 3-phase 4-wire NPC inverter system is developed as Power Quality Conditioner using an effectual three dimensional Space Vector Modulation (3D-SVM technique. The proposed system behaves like a UPQC with shunt and series active filter under balanced and unbalanced loading conditions. In addition to the improvement of the power quality issues, it also balances the neutral point voltage and voltage balancing across the capacitors under unbalanced condition. The hardware and simulation results of proposed system are compared with 2D-SVM and 3D-SVM. The proposed system is stimulated using MATLAB and the hardware is designed using FPGA. From the results it is evident that effectual 3D-SVM technique gives better performance compared to other control methods.

  18. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...... new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as “wired to freedom,” we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear...

  19. Wiring and lighting

    CERN Document Server

    Kitcher, Chris

    2013-01-01

    Wiring and Lighting provides a comprehensive guide to DIY wiring around the home. It sets out the regulations and legal requirements surrounding electrical installation work, giving clear guidelines that will enable the reader to understand what electrical work they are able to carry out, and what the testing and certification requirements are once the work is completed. Topics covered include: Different types of circuits; Types of cables and cable installation under floors and through joists; Isolating, earthing and bonding; Accessory boxes and fixings; Voltage bands; Detailed advice on safe

  20. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  1. Advanced optical 3D scanners using DMD technology

    Science.gov (United States)

    Muenstermann, P.; Godding, R.; Hermstein, M.

    2017-02-01

    Optical 3D measurement techniques are state-of-the-art for highly precise, non-contact surface scanners - not only in industrial development, but also in near-production and even in-line configurations. The need for automated systems with very high accuracy and clear implementation of national precision standards is growing extremely due to expanding international quality guidelines, increasing production transparency and new concepts related to the demands of the fourth industrial revolution. The presentation gives an overview about the present technical concepts for optical 3D scanners and their benefit for customers and various different applications - not only in quality control, but also in design centers or in medical applications. The advantages of DMD-based systems will be discussed and compared to other approaches. Looking at today's 3D scanner market, there is a confusing amount of solutions varying from lowprice solutions to high end systems. Many of them are linked to a very special target group or to special applications. The article will clarify the differences of the approaches and will discuss some key features which are necessary to render optical measurement systems suitable for industrial environments. The paper will be completed by examples for DMDbased systems, e. g. RGB true-color systems with very high accuracy like the StereoScan neo of AICON 3D Systems. Typical applications and the benefits for customers using such systems are described.

  2. An open-source, FireWire camera-based, Labview-controlled image acquisition system for automated, dynamic pupillometry and blink detection.

    Science.gov (United States)

    de Souza, John Kennedy Schettino; Pinto, Marcos Antonio da Silva; Vieira, Pedro Gabrielle; Baron, Jerome; Tierra-Criollo, Carlos Julio

    2013-12-01

    The dynamic, accurate measurement of pupil size is extremely valuable for studying a large number of neuronal functions and dysfunctions. Despite tremendous and well-documented progress in image processing techniques for estimating pupil parameters, comparatively little work has been reported on practical hardware issues involved in designing image acquisition systems for pupil analysis. Here, we describe and validate the basic features of such a system which is based on a relatively compact, off-the-shelf, low-cost FireWire digital camera. We successfully implemented two configurable modes of video record: a continuous mode and an event-triggered mode. The interoperability of the whole system is guaranteed by a set of modular software components hosted on a personal computer and written in Labview. An offline analysis suite of image processing algorithms for automatically estimating pupillary and eyelid parameters were assessed using data obtained in human subjects. Our benchmark results show that such measurements can be done in a temporally precise way at a sampling frequency of up to 120 Hz and with an estimated maximum spatial resolution of 0.03 mm. Our software is made available free of charge to the scientific community, allowing end users to either use the software as is or modify it to suit their own needs. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Development of a dual-energy computed tomography quality control program: Characterization of scanner response and definition of relevant parameters for a fast-kVp switching dual-energy computed tomography system.

    Science.gov (United States)

    Nute, Jessica L; Jacobsen, Megan C; Stefan, Wolfgang; Wei, Wei; Cody, Dianna D

    2018-04-01

    A prototype QC phantom system and analysis process were developed to characterize the spectral capabilities of a fast kV-switching dual-energy computed tomography (DECT) scanner. This work addresses the current lack of quantitative oversight for this technology, with the goal of identifying relevant scan parameters and test metrics instrumental to the development of a dual-energy quality control (DEQC). A prototype elliptical phantom (effective diameter: 35 cm) was designed with multiple material inserts for DECT imaging. Inserts included tissue equivalent and material rods (including iodine and calcium at varying concentrations). The phantom was scanned on a fast kV-switching DECT system using 16 dual-energy acquisitions (CTDIvol range: 10.3-62 mGy) with varying pitch, rotation time, and tube current. The circular head phantom (22 cm diameter) was scanned using a similar protocol (12 acquisitions; CTDIvol range: 36.7-132.6 mGy). All acquisitions were reconstructed at 50, 70, 110, and 140 keV and using a water-iodine material basis pair. The images were evaluated for iodine quantification accuracy, stability of monoenergetic reconstruction CT number, noise, and positional constancy. Variance component analysis was used to identify technique parameters that drove deviations in test metrics. Variances were compared to thresholds derived from manufacturer tolerances to determine technique parameters that had a nominally significant effect on test metrics. Iodine quantification error was largely unaffected by any of the technique parameters investigated. Monoenergetic HU stability was found to be affected by mAs, with a threshold under which spectral separation was unsuccessful, diminishing the utility of DECT imaging. Noise was found to be affected by CTDIvol in the DEQC body phantom, and CTDIvol and mA in the DEQC head phantom. Positional constancy was found to be affected by mAs in the DEQC body phantom and mA in the DEQC head phantom. A streamlined scan protocol

  4. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  5. Wire EDM for Refractory Materials

    Science.gov (United States)

    Zellars, G. R.; Harris, F. E.; Lowell, C. E.; Pollman, W. M.; Rys, V. J.; Wills, R. J.

    1982-01-01

    In an attempt to reduce fabrication time and costs, Wire Electrical Discharge Machine (Wire EDM) method was investigated as tool for fabricating matched blade roots and disk slots. Eight high-strength nickel-base superalloys were used. Computer-controlled Wire EDM technique provided high quality surfaces with excellent dimensional tolerances. Wire EDM method offers potential for substantial reductions in fabrication costs for "hard to machine" alloys and electrically conductive materials in specific high-precision applications.

  6. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  7. Command Wire Sensor Measurements

    Science.gov (United States)

    2012-09-01

    CFAR Constant False Alarm Rate CWIE Command Wire-Improvised Explosive Device EMI Electromagnetic Induction GPR Ground Penetrating Radar...this, some type of constant false alarm rate ( CFAR ) receiver is required. CFAR automatically raises the threshold level to keep clutter echoes and

  8. Transport in quantum wires

    Indian Academy of Sciences (India)

    Transport in quantum wires. SIDDHARTHA LAL, SUMATHI RAO£ and DIPTIMAN SEN. Centre for Theoretical Studies, Indian Institute of Science, Bangalore 560 012, India. £ Harish-chandra Research Institute, Chhatnag Road, Jhusi, Allahabad 211 019, India. Abstract. With a brief introduction to one-dimensional channels ...

  9. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  10. Data acquisition system development for the detection of X-ray photons in multi-wire gas proportional counters

    International Nuclear Information System (INIS)

    Kimpton, J.A.; Kinnane, M.N.; Smale, L.F.; Chantler, C.T.; Hudson, L.T.; Henins, A.; Szabo, C.I.; Gillaspy, J.D.; Tan, J.N.; Pomeroy, J.M.; Takacs, E.; Radics, B.

    2007-01-01

    A new data acquisition system coupled to a backgammon-type gas proportional counter capable of single-photon counting over a wide range of count rates has been developed and replaces a CAMAC-based system. The new apparatus possesses improved architecture, interface technology, speed and diagnostic capability. System efficiency and throughput is significantly improved, especially in addressing earlier problems of hardware buffer downloads containing zero or repeat data and inefficient gating control. The new system is a PXI-based data acquisition apparatus including additional electronics, controlled by a graphical programming environment. It allows development of superior diagnostic tools for system optimisation and more stable performance. System efficiency is improved by 10% over a wide range of count rates (0.5 Hz-50 kHz). For the Backgammon Detector type, this represents a significant improvement in performance and applicability over previous systems. Characteristic and few-electron spectra collected on the new acquisition system are illustrated

  11. STRS SpaceWire FPGA Module

    Science.gov (United States)

    Lux, James P.; Taylor, Gregory H.; Lang, Minh; Stern, Ryan A.

    2011-01-01

    An FPGA module leverages the previous work from Goddard Space Flight Center (GSFC) relating to NASA s Space Telecommunications Radio System (STRS) project. The STRS SpaceWire FPGA Module is written in the Verilog Register Transfer Level (RTL) language, and it encapsulates an unmodified GSFC core (which is written in VHDL). The module has the necessary inputs/outputs (I/Os) and parameters to integrate seamlessly with the SPARC I/O FPGA Interface module (also developed for the STRS operating environment, OE). Software running on the SPARC processor can access the configuration and status registers within the SpaceWire module. This allows software to control and monitor the SpaceWire functions, but it is also used to give software direct access to what is transmitted and received through the link. SpaceWire data characters can be sent/received through the software interface, as well as through the dedicated interface on the GSFC core. Similarly, SpaceWire time codes can be sent/received through the software interface or through a dedicated interface on the core. This innovation is designed for plug-and-play integration in the STRS OE. The SpaceWire module simplifies the interfaces to the GSFC core, and synchronizes all I/O to a single clock. An interrupt output (with optional masking) identifies time-sensitive events within the module. Test modes were added to allow internal loopback of the SpaceWire link and internal loopback of the client-side data interface.

  12. A micron resolution optical scanner for characterization of silicon detectors

    International Nuclear Information System (INIS)

    Shukla, R. A.; Dugad, S. R.; Gopal, A. V.; Gupta, S. K.; Prabhu, S. S.; Garde, C. S.

    2014-01-01

    The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper

  13. Symptoms and Cognitive Effects of Exposure to Magnetic Stray Fields of MRI Scanners

    NARCIS (Netherlands)

    Vocht, Frank Gérard de

    2006-01-01

    People working routinely with magnetic resonance imaging (MRI) systems report a number of symptoms related to their presence in the inhomogeneous static magnetic fields (the stray field) surrounding these scanners. Experienced symptoms and neurobehavioral performance among engineers manufacturing

  14. An image scanner for real time analysis of spark chamber images

    International Nuclear Information System (INIS)

    Cesaroni, F.; Penso, G.; Locci, A.M.; Spano, M.A.

    1975-01-01

    The notes describes the semiautomatic scanning system at LNF for the analysis of spark chamber images. From the projection of the images on the scanner table, the trajectory in the real space is reconstructed

  15. Digital Data Matrix Scanner Developnent At Marshall Space Flight Center

    Science.gov (United States)

    2004-01-01

    Research at NASA's Marshall Space Flight Center has resulted in a system for reading hidden identification codes using a hand-held magnetic scanner. It's an invention that could help businesses improve inventory management, enhance safety, improve security, and aid in recall efforts if defects are discovered. Two-dimensional Data Matrix symbols consisting of letters and numbers permanently etched on items for identification and resembling a small checkerboard pattern are more efficient and reliable than traditional bar codes, and can store up to 100 times more information. A team led by Fred Schramm of the Marshall Center's Technology Transfer Department, in partnership with PRI,Torrance, California, has developed a hand-held device that can read this special type of coded symbols, even if covered by up to six layers of paint. Before this new technology was available, matrix symbols were read with optical scanners, and only if the codes were visible. This latest improvement in digital Data Matrix technologies offers greater flexibility for businesses and industries already using the marking system. Paint, inks, and pastes containing magnetic properties are applied in matrix symbol patterns to objects with two-dimensional codes, and the codes are read by a magnetic scanner, even after being covered with paint or other coatings. The ability to read hidden matrix symbols promises a wide range of benefits in a number of fields, including airlines, electronics, healthcare, and the automotive industry. Many industries would like to hide information on a part, so it can be read only by the party who put it there. For instance, the automotive industry uses direct parts marking for inventory control, but for aesthetic purposes the marks often need to be invisible. Symbols have been applied to a variety of materials, including metal, plastic, glass, paper, fabric and foam, on everything from electronic parts to pharmaceuticals to livestock. The portability of the hand

  16. Research regarding wires elastic deformations influence on joints positioning of a wire-driven robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-08-01

    In this paper, we present the influence of driving wires deformation on positioning precision of joints from an elephant's trunk robotic arm. Robotic arms driven by wires have the joint accuracy largely depending on wires rigidity. The joint moment of resistance causes elastic deformation of wires and it is determined by: manipulated object load, weight loads previous to the analyzed joint and inherent resistance moment of joint. Static load analysis emphasizes the particular wires elastic deformation of each driven joint from an elephant's trunk robotic arm with five degrees of freedom. We consider the case of a constant manipulated load. Errors from each driving system of joints are not part of the closed loop system. Thus, precision positioning depends on wires elastic deformation which is about microns and causes angle deviation of joints about tens of minutes of sexagesimal degrees. The closer the joints to base arm the smaller positioning precision of joint. The obtained results are necessary for further compensation made by electronic corrections in the programming algorithm of the elephant's trunk robotic arm to improve accuracy.

  17. A Cross-Platform Smartphone Brain Scanner

    DEFF Research Database (Denmark)

    Larsen, Jakob Eg; Stopczynski, Arkadiusz; Stahlhut, Carsten

    We describe a smartphone brain scanner with a low-costwireless 14-channel Emotiv EEG neuroheadset interfacingwith multiple mobile devices. This personal informaticssystem enables minimally invasive and continuouscapturing of brain imaging data in natural settings. Thesystem applies an inverse...

  18. 46 CFR 120.340 - Cable and wiring requirements.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cable and wiring requirements. 120.340 Section 120.340 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... INSTALLATION Power Sources and Distribution Systems § 120.340 Cable and wiring requirements. (a) If individual...

  19. 46 CFR 183.340 - Cable and wiring requirements.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Cable and wiring requirements. 183.340 Section 183.340 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.340 Cable and wiring...

  20. Distribution of Energy Deposited in Plastic Tubing and Copper-Wire Insulation by Electron Beam Irradiation

    DEFF Research Database (Denmark)

    Pedersen, Walther Batsberg; Miller, Arne; Pejtersen, K.

    1978-01-01

    Scanned electron beam treatment is used to improve the physical properties of certain polymers, such as shrinkable plastic tubing and insulated wire and cable. Tubing or wires are passed at high speed under the beam scanner, and the material is irradiated to absorbed doses of several Mrad...... as uniformly as possible, usually by means of a multipass arrangement. In the present study, using irradiation by a scanned 0.4 MeV electron beam, measurements were made of high-resolution distributions of absorbed dose in polyethylene tubing and copper wire coated with polyethylene, nylon, or polyvinyl...... chloride insulation. Radiochromic dye films equivalent to the insulating materials were used as accurate dosimeters having a response independent of dose rate. Irradiations were in various geometries, wire and plastic thicknesses, positions along the beam scan, and with different backing materials near...

  1. Robust Object Segmentation Using a Multi-Layer Laser Scanner

    Science.gov (United States)

    Kim, Beomseong; Choi, Baehoon; Yoo, Minkyun; Kim, Hyunju; Kim, Euntai

    2014-01-01

    The major problem in an advanced driver assistance system (ADAS) is the proper use of sensor measurements and recognition of the surrounding environment. To this end, there are several types of sensors to consider, one of which is the laser scanner. In this paper, we propose a method to segment the measurement of the surrounding environment as obtained by a multi-layer laser scanner. In the segmentation, a full set of measurements is decomposed into several segments, each representing a single object. Sometimes a ghost is detected due to the ground or fog, and the ghost has to be eliminated to ensure the stability of the system. The proposed method is implemented on a real vehicle, and its performance is tested in a real-world environment. The experiments show that the proposed method demonstrates good performance in many real-life situations. PMID:25356645

  2. Robust Object Segmentation Using a Multi-Layer Laser Scanner

    Directory of Open Access Journals (Sweden)

    Beomseong Kim

    2014-10-01

    Full Text Available The major problem in an advanced driver assistance system (ADAS is the proper use of sensor measurements and recognition of the surrounding environment. To this end, there are several types of sensors to consider, one of which is the laser scanner. In this paper, we propose a method to segment the measurement of the surrounding environment as obtained by a multi-layer laser scanner. In the segmentation, a full set of measurements is decomposed into several segments, each representing a single object. Sometimes a ghost is detected due to the ground or fog, and the ghost has to be eliminated to ensure the stability of the system. The proposed method is implemented on a real vehicle, and its performance is tested in a real-world environment. The experiments show that the proposed method demonstrates good performance in many real-life situations.

  3. A new type of rapid and simple coal and other bulk commodities inventory system based on two-dimensional laser scanner

    Science.gov (United States)

    Liang, Qianqian; Xu, Wenhai; Ma, Qisheng; Yang, Deshan; Zhang, Wang; Fu, Ying

    2016-10-01

    The acceleration of large coal base construction needs the modern management technology of heap storage as a guarantee. And the inventory of coal and other bulk commodities is an important aspect in the modern management technology of heap storage. Therefore, a rapid, accurate and simple method to measure the volume and quality of coal heaps for scientific management, economic benefit evaluation and storage evaluation of heap storage is very important which has a significant application value. In this paper, we introduce the structural features, working principle and application status of a new type portable heap bulk inventory system. Actual measurements have been carried out in the coal base located in Huanghua port, Tianjin and Qinhuangdao. The measurement results indicate that the system can measure the volume of bulk commodities efficiently, quickly and accurately, and it has extensive application prospects.

  4. NiTi SMA Wires Coupled with Kevlar Fabric: a Real Application of an Innovative Aircraft LE Slat System in SMAHC Material

    Science.gov (United States)

    Guida, M.; Marulo, F.; Russo, S.

    2017-08-01

    This paper investigates experimentally and numerically the response of a smart hybrid thermoplastic aircraft slat system subjected to a short-duration and high-frequency event like a birdstrike. The focus of the paper is to exploit the ability that superelastic shape memory alloys have to absorb and dissipate energy compared to conventional composite structures. The final objective of the work is to develop an innovative thermoplastic wing leading edge slat able to resist to an impact of 4-lb (1.8 kg) bird at speed of 350 kts (132 m/s), as requested by the aeronautical requirements. Aircraft leading edges must be certified for a proven level of bird impact resistance. In particular, the main structural requirement is to protect the torsion box and control devices from any significant damage caused by birdstrike in order to allow the aircraft to land safely. A clear increase of the composites toughness and higher absorbed energy levels before failure were also observed. This is due to the fact that SMA wires can absorb kinetic energy during the impact due to their remarkably large failure and recoverable strain and to their superelastic and hysteretic behaviour. The activities have been performed within the European Project COALESCE "Cost Efficient Advanced Leading Edge Structure", funded by the Seventh Framework Program Theme 7 Transport (incl. Aeronautics).

  5. NiTi SMA Wires Coupled with Kevlar Fabric: a Real Application of an Innovative Aircraft LE Slat System in SMAHC Material

    Science.gov (United States)

    Guida, M.; Marulo, F.; Russo, S.

    2018-04-01

    This paper investigates experimentally and numerically the response of a smart hybrid thermoplastic aircraft slat system subjected to a short-duration and high-frequency event like a birdstrike. The focus of the paper is to exploit the ability that superelastic shape memory alloys have to absorb and dissipate energy compared to conventional composite structures. The final objective of the work is to develop an innovative thermoplastic wing leading edge slat able to resist to an impact of 4-lb (1.8 kg) bird at speed of 350 kts (132 m/s), as requested by the aeronautical requirements. Aircraft leading edges must be certified for a proven level of bird impact resistance. In particular, the main structural requirement is to protect the torsion box and control devices from any significant damage caused by birdstrike in order to allow the aircraft to land safely. A clear increase of the composites toughness and higher absorbed energy levels before failure were also observed. This is due to the fact that SMA wires can absorb kinetic energy during the impact due to their remarkably large failure and recoverable strain and to their superelastic and hysteretic behaviour. The activities have been performed within the European Project COALESCE "Cost Efficient Advanced Leading Edge Structure", funded by the Seventh Framework Program Theme 7 Transport (incl. Aeronautics).

  6. Development of Cu-Hf-Al ternary systems and tungsten wire/particle reinforced Cu48Hf43Al9 bulk metallic glass composites for strengthening

    International Nuclear Information System (INIS)

    Park, Joyoung; An, Jihye; Choi-Yim, Haein

    2010-01-01

    Stable bulk glass forming alloys can be developed over a wide range of compositions in Cu-Hf-Al ternary systems starting from the Cu 49 Hf 42 Al 9 bulk metallic glass. Ternary Cu-Hf-Al alloys can be cast directly from the melt into copper molds to form fully amorphous strips with thicknesses of 1 to 6 mm. The maximum critical diameter of the new Cu-Hf-Al ternary alloy was 6 mm. X-ray diffraction patterns were used to confirm the amorphous nature of the ternary Cu-Hf-Al alloys. To increase the toughness of these metallic glasses, we reinforced the Cu 48 Hf 43 Al 9 bulk metallic glass-forming liquid with a 50% volume fraction of tungsten particles and an 80% volume fraction of tungsten wires with diameters of 242.4 μm. Composites with a critical diameter of 7 mm and length 70 mm were synthesized. The structure of the composites was confirmed by using X-ray diffraction (XRD), and the scanning electron microscopy (SEM). The mechanical properties of the composites were studied in compression tests. The thermal stability and the crystallization processes of the Cu-Hf-Al alloys and composites were investigated by using differential scanning calorimetry (DSC). Values of the glass transition temperature (T g ), the crystallization temperature (T x ), and the supercooled liquid region (ΔT = T x - T g ) are given in this paper.

  7. Automatic inventory of components by laser 3D scanner

    International Nuclear Information System (INIS)

    Rodriguez Garcia, R.; Munoz Prieto, C.; Sarti Fernandez, F.

    2014-01-01

    One of the existing needs in nuclear decommissioning projects is to provide an inventory of components to be dismantled, which is available from its spatial location and elements that exist in your environment. The Laser scanner technology is a system of data acquisition that allows 3D models composed of millions of points, it's models with pinpoint accuracy and are available in a very short space of time. (Author)

  8. Whole body x-ray CT scanner, TCT-900S

    International Nuclear Information System (INIS)

    Mori, Issei; Saito, Kiyoto; Asahina, Kiyotaka

    1987-01-01

    The fundamental parameters of an X-ray CT (computed tomography) scanner are temporal, spatial, and density resolution. Research projects to improve these parameters had reached a standstill until recently. Toshiba has achieved a breakthrough with the development of a new CT system, the TCT-900S, which incorporates a new scanning configuration and several technological improvements. The TCT-900S is already in clinical use in many hospitals nationwide, and new diagnostic applications are being explored. (author)

  9. Cockpit canopy shattering using exploding wire techniques

    International Nuclear Information System (INIS)

    Novac, B M; Smith, I R; Downs, P R; Marston, P; Fahey, D

    2007-01-01

    This paper presents the principal experimental results provided by a preliminary investigation into the possibility of using exploding wire (EW) techniques to shatter the plastic cockpit canopy of a modern jet aircraft. The data provided forms the basis for a qualitative understanding of the physics of interaction between the plasma produced by an EW and the surrounding elasto-plastic material in which the wire is embedded. To optimize the shock-wave 'clean cutting' effect, the significance of the material, the dimensions of the exploding wire and the amplitude of the current and voltage pulses are all considered. This leads to important conclusions concerning both the characteristics of the EW and the optimum arrangement of the electrical circuit, with the single most important optimization factor being the peak electrical power input to the EW, rather than the dissipated Joule energy. A full-scale system relevant to an actual cockpit canopy shattering is outlined and relevant results are presented and discussed

  10. Dental Arch Wire

    Science.gov (United States)

    1979-01-01

    Straightening teeth is an arduous process requiring months, often years, of applying corrective pressure by means of arch wires-better known as brace-which may have to be changed several times in the course of treatment. A new method has been developed by Dr. George Andreasen, orthodontist and dental scientist at the University of Iowa. The key is a new type of arch wire material, called Nitinol, with exceptional elasticity which helps reduce the required number of brace changes. An alloy of nickel and titanium, Nitinol was originally developed for aerospace applications by the Naval Ordnance Laboratory, now the Naval Surface Weapons Laboratory, White Oaks, Maryland. NASA subsequently conducted additional research on the properties of Nitinol and on procedures for processing the metal.

  11. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  12. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  13. Near-field optical spectroscopy of semiconductor quantum wires

    Science.gov (United States)

    Gershoni, D.; Harris, T. D.; Pfeiffer, L. N.

    1997-09-01

    We discuss low temperature near-field scanning optical spectroscopical studies of single, nanometer dimension, cleaved edge overgrown quantum wires. We use the enhanced spatial resolution of near-field microscopy, to spectroscopically investigate these single wires, which are inaccessible to conventional far-field optical spectroscopy. We thus performed a direct experimental comparison between a two-dimensional quantum system and a single genuine one-dimensional quantum system. We show that the photoluminescence of a single quantum wire is easily distinguished from that of the surrounding quantum well. Emission from localized centers is shown to dominate the photoluminescence from both wires and wells at low temperatures. A factor of three enhancement in the optical absorption of a wire, in comparison with that of a similar well, is concluded from the photoluminescence excitation data.

  14. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  15. Open borders for system-on-a-chip buses: A wire format for connecting large physics controls

    Directory of Open Access Journals (Sweden)

    M. Kreider

    2012-08-01

    Full Text Available System-on-a-chip (SoC bus systems are typically confined on-chip and rely on higher level components to communicate with the outside world. The idea behind the EtherBone (EB protocol is to extend the reach of the SoC bus to remote field-programmable gate arrays or processors. The EtherBone core implementation connects a Wishbone (WB Ver. 4 Bus via a Gigabit Ethernet based network link to remote peripheral devices. EB acts as a transparent interconnect module towards attached WB Bus devices. EB was developed in the scope of the WhiteRabbit Timing Project at CERN and GSI/FAIR. WhiteRabbit will make use of EB as a means to issue commands to its timing nodes and control connected accelerator hardware.

  16. Reusable Hot-Wire Cable Cutter

    Science.gov (United States)

    Pauken, Michael T.; Steinkraus, Joel M.

    2010-01-01

    During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which

  17. Object 3D surface reconstruction approach using portable laser scanner

    Science.gov (United States)

    Xu, Ning; Zhang, Wei; Zhu, Liye; Li, Changqing; Wang, Shifeng

    2017-06-01

    The environment perception plays the key role for a robot system. The 3D surface of the objects can provide essential information for the robot to recognize objects. This paper present an approach to reconstruct objects' 3D surfaces using a portable laser scanner we designed which consists of a single-layer laser scanner, an encoder, a motor, power supply and mechanical components. The captured point cloud data is processed to remove the discrete points, denoise filtering, stitching and registration. Then the triangular mesh generation of point cloud is accomplished by using Gaussian bilateral filtering, ICP real-time registration and greedy triangle projection algorithm. The experiment result shows the feasibility of the device designed and the algorithm proposed.

  18. A development of assistant surgical robot system based on surgical-operation-by-wire and hands-on-throttle-and-stick.

    Science.gov (United States)

    Kim, Myungjoon; Lee, Chiwon; Park, Woo Jung; Suh, Yun Suhk; Yang, Han Kwang; Kim, H Jin; Kim, Sungwan

    2016-05-20

    Robot-assisted laparoscopic surgery offers several advantages compared with open surgery and conventional minimally invasive surgery. However, one issue that needs to be resolved is a collision between the robot arm and the assistant instrument. This is mostly caused by miscommunication between the surgeon and the assistant. To resolve this limitation, an assistant surgical robot system that can be simultaneously manipulated via a wireless controller is proposed to allow the surgeon to control the assistant instrument. The system comprises two novel master interfaces (NMIs), a surgical instrument with a gripper actuated by a micromotor, and 6-axis robot arm. Two NMIs are attached to master tool manipulators of da Vinci research kit (dVRK) to control the proposed system simultaneously with patient side manipulators of dVRK. The developments of the surgical instrument and NMI are based on surgical-operation-by-wire concept and hands-on-throttle-and-stick concept from the earlier research, respectively. Tests for checking the accuracy, latency, and power consumption of the NMI are performed. The gripping force, reaction time, and durability are assessed to validate the surgical instrument. The workspace is calculated for estimating the clinical applicability. A simple peg task using the fundamentals of laparoscopic surgery board and an in vitro test are executed with three novice volunteers. The NMI was operated for 185 min and reflected the surgeon's decision successfully with a mean latency of 132 ms. The gripping force of the surgical instrument was comparable to that of conventional systems and was consistent even after 1000 times of gripping motion. The reaction time was 0.4 s. The workspace was calculated to be 8397.4 cm(3). Recruited volunteers were able to execute the simple peg task within the cut-off time and successfully performed the in vitro test without any collision. Various experiments were conducted and it is verified that the proposed assistant

  19. Exploiting Indoor Mobile Laser Scanner Trajectories for Semantic Interpretation of Point Clouds

    Science.gov (United States)

    Nikoohemat, S.; Peter, M.; Oude Elberink, S.; Vosselman, G.

    2017-09-01

    The use of Indoor Mobile Laser Scanners (IMLS) for data collection in indoor environments has been increasing in the recent years. These systems, unlike Terrestrial Laser Scanners (TLS), collect data along a trajectory instead of at discrete scanner positions. In this research, we propose several methods to exploit the trajectories of IMLS systems for the interpretation of point clouds. By means of occlusion reasoning and use of trajectory as a set of scanner positions, we are capable of detecting openings in cluttered indoor environments. In order to provide information about both the partitioning of the space and the navigable space, we use the voxel concept for point clouds. Furthermore, to reconstruct walls, floor and ceiling we exploit the indoor topology and plane primitives. The results show that the trajectory is a valuable source of data for feature detection and understanding of indoor MLS point clouds.

  20. EXPLOITING INDOOR MOBILE LASER SCANNER TRAJECTORIES FOR SEMANTIC INTERPRETATION OF POINT CLOUDS

    Directory of Open Access Journals (Sweden)

    S. Nikoohemat

    2017-09-01

    Full Text Available The use of Indoor Mobile Laser Scanners (IMLS for data collection in indoor environments has been increasing in the recent years. These systems, unlike Terrestrial Laser Scanners (TLS, collect data along a trajectory instead of at discrete scanner positions. In this research, we propose several methods to exploit the trajectories of IMLS systems for the interpretation of point clouds. By means of occlusion reasoning and use of trajectory as a set of scanner positions, we are capable of detecting openings in cluttered indoor environments. In order to provide information about both the partitioning of the space and the navigable space, we use the voxel concept for point clouds. Furthermore, to reconstruct walls, floor and ceiling we exploit the indoor topology and plane primitives. The results show that the trajectory is a valuable source of data for feature detection and understanding of indoor MLS point clouds.

  1. Digitizing implant position locators on master casts: comparison of a noncontact scanner and a contact-probe scanner.

    Science.gov (United States)

    Holst, Stefan; Persson, Anna; Wichmann, Manfred; Karl, Matthias

    2012-01-01

    Although several investigations of the fit of computer-aided design/computer-assisted manufactured implant restorations have been reported in the literature, very limited information is available on the accuracy of dental scanners for surface data acquisition. The objective of this research project was to investigate the accuracy and repeatability of a three-dimensional noncontact laser scanning system based on conoscopic holography recording the spatial orientation of an implant in vitro. One master cast containing five nonparallel implant replicas with scan abutments (implant position locator [IPL], Nobel Biocare) was repeatedly digitized by two commercially available dental scanners and an industrial highprecision coordinate measuring machine as a reference. Repeated measurements of the center point and vector analysis were applied to determine the accuracy and repeatability of IPL orientation. The Wilcoxon signed rank test modified for equivalence was applied to determine whether the systems were equally accurate based on given threshold limits of 0.010, 0.005, and 0.001 mm. All between-system tests identified significant differences, although most differences were very small in absolute terms. Tests for equivalence based on difference windows were exploratorily significant for 0.010 and 0.005 mm. Conoscopic holography scan technology is a valid option to supplement dental touch-probe scanners for laboratory digitization of implant master casts.

  2. A comparative study of frictional resistance and surface roughness between orthodontic bracket and arch wire

    OpenAIRE

    Kazuro, SATOH; Masaru, ISHIGAME; Yukiko, NAKAMURA; Kazushi, OGASAWARA; Shigeru, TANAKA; Hiroyuki, MIURA; Department of Orthodontics, School of Dentistry, Iwate Medical University; Department of Orthodontics, School of Dentistry, Iwate Medical University; Department of Orthodontics, School of Dentistry, Iwate Medical University; Department of Orthodontics, School of Dentistry, Iwate Medical University; Department of Orthodontics, School of Dentistry, Iwate Medical University; Department of Orthodontics, School of Dentistry, Iwate Medical University

    2003-01-01

    The frictional resistance between an orthodontic bracket and arch wire is closely related to the efficiency of tooth movement in sliding mechanics. Frictional resistance may arise from the materials, geometrical configuration between the orthodontic bracket and arch wire, ligation system and its force, wire stiffness, direction and degree of orthodontic force, and surface roughness of bracket and wire. This study examined the relationship between the frictional resistance and surface roughnes...

  3. Numerical model for electrical explosion of copper wires in water

    Science.gov (United States)

    Chung, Kyoung-Jae; Lee, Kern; Hwang, Y. S.; Kim, Deok-Kyu

    2016-11-01

    This paper presents a simple but quite accurate numerical model for analyzing electrical explosion of copper wires in water. The numerical model solves a circuit equation coupled with one-dimensional magneto-hydrodynamic (MHD) equations with the help of appropriate wide-range equation of state (EOS) and electrical conductivity for copper. The MHD equations are formulated in a Lagrangian form to identify the interface between the wire and surrounding water clearly. A quotidian EOS (QEOS) that is known as the simplest form of EOS is utilized to build wide-range EOS for copper. In the QEOS, we consider the liquid-vapor phase transition, which is critical in analyzing the wire explosion system. For the electrical conductivity of copper, a semi-empirical set of equations covering from solid state to partially ionized plasma state are employed. Experimental validation has been performed with copper wires of various diameters, which are exploded by a microsecond timescale pulsed capacitive discharge. The simulation results show excellent agreements with the experimental results in terms of temporal motions of a plasma channel boundary and a shock front as well as current and voltage waveforms. It is found that the wire explodes (vaporizes) along the liquid branch of a binodal curve irrespective of wire dimension and operating voltage. After the explosion, the wire becomes a plasma state right away or after the current pause (dwell), depending on the operating conditions. It is worth noting that such a peculiar characteristic of wire explosion, i.e., current pause and restrike, is well simulated with the present numerical model. In particular, it is shown that the wire cools down along the vapor branch of the binodal curve during the current dwell, due to a significant difference of thermodynamic characteristics across the binodal curve. The influence of radiation for studying nonideal plasmas with a wire explosion technique and a physical process for shock wave formation

  4. Portable wide-field hand-held NIR scanner

    Science.gov (United States)

    Jung, Young-Jin; Roman, Manuela; Carrasquilla, Jennifer; Erickson, Sarah J.; Godavarty, Anuradha

    2013-03-01

    Near-infrared (NIR) optical imaging modality is one of the widely used medical imaging techniques for breast cancer imaging, functional brain mapping, and many other applications. However, conventional NIR imaging systems are bulky and expensive, thereby limiting their accelerated clinical translation. Herein a new compact (6 × 7 × 12 cm3), cost-effective, and wide-field NIR scanner has been developed towards contact as well as no-contact based real-time imaging in both reflectance and transmission mode. The scanner mainly consists of an NIR source light (between 700- 900 nm), an NIR sensitive CCD camera, and a custom-developed image acquisition and processing software to image an area of 12 cm2. Phantom experiments have been conducted to estimate the feasibility of diffuse optical imaging by using Indian-Ink as absorption-based contrast agents. As a result, the developed NIR system measured the light intensity change in absorption-contrasted target up to 4 cm depth under transillumination mode. Preliminary in-vivo studies demonstrated the feasibility of real-time monitoring of blood flow changes. Currently, extensive in-vivo studies are carried out using the ultra-portable NIR scanner in order to assess the potential of the imager towards breast imaging..

  5. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  6. Experimental characterization of the Clear-PEM scanner spectrometric performance

    Science.gov (United States)

    Bugalho, R.; Carriço, B.; Ferreira, C. S.; Frade, M.; Ferreira, M.; Moura, R.; Ortigão, C.; Pinheiro, J. F.; Rodrigues, P.; Rolo, I.; Silva, J. C.; Trindade, A.; Varela, J.

    2009-10-01

    In the framework of the Clear-PEM project for the construction of a high-resolution and high-specificity scanner for breast cancer imaging, a Positron Emission Mammography tomograph has been developed and installed at the Instituto Português de Oncologia do Porto hospital. The Clear-PEM scanner is mainly composed by two planar detector heads attached to a robotic arm, trigger/data acquisition electronics system and computing servers. The detector heads hold crystal matrices built from 2 × 2 × 20 mm3 LYSO:Ce crystals readout by Hamamatsu S8550 APD arrays. The APDs are optically coupled to both ends of the 6144 crystals in order to extract the DOI information for each detected event. Each one of 12288 APD's pixels is read and controlled by Application Specific Integrated Circuits water-cooled by an external cooling unit. The Clear-PEM frontend boards innovative design results in a unprecedented integration of the crystal matrices, APDs and ASICs, making Clear-PEM the PET scanner with the highest number of APD pixels ever integrated so far. In this paper, the scanner's main technical characteristics, calibration strategies and the first spectrometric performance evaluation in a clinical environment are presented. The first commissioning results show 99.7% active channels, which, after calibration, have inter-pixel and absolute gain distributions with dispersions of, respectively, 12.2% and 15.3%, demonstrating that despite the large number of channels, the system is uniform. The mean energy resolution at 511 keV is of 15.9%, with a 8.8% dispersion, and the mean CDOI-1 is 5.9%/mm, with a 7.8% dispersion. The coincidence time resolution, at 511 keV, for a energy window between 400 and 600 keV, is 5.2 ns FWHM.

  7. Experimental characterization of the Clear-PEM scanner spectrometric performance

    Energy Technology Data Exchange (ETDEWEB)

    Bugalho, R; Carrico, B; Ferreira, C S; Frade, M; Ferreira, M; Moura, R; Ortigao, C; Pinheiro, J F; Rodrigues, P; Rolo, I; Silva, J C; Trindade, A; Varela, J [Laboratorio de Instrumentacao e Fisica Experimental de Particulas (LIP), Av. Elias Garcia 14-1, 1000-149 Lisboa (Portugal)], E-mail: frade@lip.pt

    2009-10-15

    In the framework of the Clear-PEM project for the construction of a high-resolution and high-specificity scanner for breast cancer imaging, a Positron Emission Mammography tomograph has been developed and installed at the Instituto Portugues de Oncologia do Porto hospital. The Clear-PEM scanner is mainly composed by two planar detector heads attached to a robotic arm, trigger/data acquisition electronics system and computing servers. The detector heads hold crystal matrices built from 2 x 2 x 20 mm{sup 3} LYSO:Ce crystals readout by Hamamatsu S8550 APD arrays. The APDs are optically coupled to both ends of the 6144 crystals in order to extract the DOI information for each detected event. Each one of 12288 APD's pixels is read and controlled by Application Specific Integrated Circuits water-cooled by an external cooling unit. The Clear-PEM frontend boards innovative design results in a unprecedented integration of the crystal matrices, APDs and ASICs, making Clear-PEM the PET scanner with the highest number of APD pixels ever integrated so far. In this paper, the scanner's main technical characteristics, calibration strategies and the first spectrometric performance evaluation in a clinical environment are presented. The first commissioning results show 99.7% active channels, which, after calibration, have inter-pixel and absolute gain distributions with dispersions of, respectively, 12.2% and 15.3%, demonstrating that despite the large number of channels, the system is uniform. The mean energy resolution at 511 keV is of 15.9%, with a 8.8% dispersion, and the mean C{sub DOI}{sup -1} is 5.9%/mm, with a 7.8% dispersion. The coincidence time resolution, at 511 keV, for a energy window between 400 and 600 keV, is 5.2 ns FWHM.

  8. Characterization of a cone beam optical scanner

    International Nuclear Information System (INIS)

    Ravindran, P B; Thomas, H M

    2013-01-01

    The use of radiochromic FX gel for mapping 3D dose distribution is hampered by the diffusion of gel and the slow scanning techniques. The development of fast optical cone beam scanning has improved the chances of using radiochromic gel as a feasible dosimeter for radiotherapy applications. In this work an optical cone beam scanner has been developed in-house and its performance characteristics have been studied. The reconstructed image of the optical scanner was analyzed by studying the resolution, signal-to-noise ratio and contrast to noise ratio (CNR). The resolution of the optical cone beam CT scanner was studied by scanning a catheter of 1 mm outer diameter and the scanner was able to detect the catheter. The geometrical accuracy of the reconstruction was studied by placing catheters in spiral geometry in the gel phantom and measuring the distances. It has been observed that the in-house Optical Cone beam scanner is suitable for scanning radiochromic gels for radiotherapy applications.

  9. Step by Step Design of a High Order Power Filter for Three-Phase Three-Wire Grid-connected Inverter in Renewable Energy System

    DEFF Research Database (Denmark)

    Huang, Min; Blaabjerg, Frede; Yang, Yongheng

    2013-01-01

    Traditionally, when designing an LCL-filter, a three-phase inverter is simplified as a single-phase inverter for analysis and the output phase voltage is used to calculate the inverter-side current harmonics and to design inverter-side inductor. However, for a three-phase three-wire grid-tied sys......Traditionally, when designing an LCL-filter, a three-phase inverter is simplified as a single-phase inverter for analysis and the output phase voltage is used to calculate the inverter-side current harmonics and to design inverter-side inductor. However, for a three-phase three-wire grid...

  10. Self-organization of mesoscopic silver wires by electrochemical deposition

    Directory of Open Access Journals (Sweden)

    Sheng Zhong

    2014-08-01

    Full Text Available Long, straight mesoscale silver wires have been fabricated from AgNO3 electrolyte via electrodeposition without the help of templates, additives, and surfactants. Although the wire growth speed is very fast due to growth under non-equilibrium conditions, the wire morphology is regular and uniform in diameter. Structural studies reveal that the wires are single-crystalline, with the [112] direction as the growth direction. A possible growth mechanism is suggested. Auger depth profile measurements show that the wires are stable against oxidation under ambient conditions. This unique system provides a convenient way for the study of self-organization in electrochemical environments as well as for the fabrication of highly-ordered, single-crystalline metal nanowires.

  11. A flexible and wearable terahertz scanner

    Science.gov (United States)

    Suzuki, D.; Oda, S.; Kawano, Y.

    2016-12-01

    Imaging technologies based on terahertz (THz) waves have great potential for use in powerful non-invasive inspection methods. However, most real objects have various three-dimensional curvatures and existing THz technologies often encounter difficulties in imaging such configurations, which limits the useful range of THz imaging applications. Here, we report the development of a flexible and wearable THz scanner based on carbon nanotubes. We achieved room-temperature THz detection over a broad frequency band ranging from 0.14 to 39 THz and developed a portable THz scanner. Using this scanner, we performed THz imaging of samples concealed behind opaque objects, breakages and metal impurities of a bent film and multi-view scans of a syringe. We demonstrated a passive biometric THz scan of a human hand. Our results are expected to have considerable implications for non-destructive and non-contact inspections, such as medical examinations for the continuous monitoring of health conditions.

  12. Wire communication engineering

    International Nuclear Information System (INIS)

    Son, Byeong Tae

    1997-02-01

    This book describes wire telecommunication engineering/ It is divided into eleven chapter, which deal with Introduction with development of telecommunication, voice and sound wave and communication network, Telegraphy with summary of telegraphy, code of telegraphy, communication speed, morse and telex, Telephone on structure, circuit and image telephone, Traffic on telecommunication traffic, transmission of line about theory, cable line and loaded cable, carrier communication with carrier telegraphy and carrier telephone, optical communication with types, structure, specialty, laser and equipment, DATA, Mobile telecommunication on summary, mobile telephone, radio paging and digital mobile telecommunication, ISDN with channel of ISDN, and service of ISDN, and design of telecommunication.

  13. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  14. The Micro Wire Detector

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M. E-mail: maximo.plo@cern.ch; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C

    1999-10-11

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 {mu}m{sup 2} apertures, crossed by 25 {mu}m anode strips to which it is attached by 50 {mu}m kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  15. Epitaxial semiconductor quantum wires.

    Science.gov (United States)

    Wu, J; Chen, Y H; Wang, Z G

    2008-07-01

    The investigation on the direct epitaxial quantum wires (QWR) using MBE or MOCVD has been persuited for more than two decades, more lengthy in history as compared with its quantum dot counterpart. Up to now, QWRs with various structural configurations have been produced with different growth methods. This is a reviewing article consisting mainly of two parts. The first part discusses QWRs of various configurations, together with laser devices based on them, in terms of the two growth mechanisms, self-ordering and self-assembling. The second part gives a brief review of the electrical and optical properties of QWRs.

  16. A stationary digital breast tomosynthesis scanner

    Science.gov (United States)

    Qian, Xin; Tucker, Andrew; Gidcumb, Emily; Lu, Jianping; Zhou, Otto; Spronk, Derrek; Sprenger, Frank; Zhang, Yiheng; Kennedy, Don; Farbizio, Tom; Jing, Zhenxue

    2012-03-01

    A prototype stationary digital breast tomosynthesis (s-DBT) system has been developed by retrofitting a Hologic Selenia Dimension rotating gantry tomosynthesis scanner with a spatially distributed carbon nanotube (CNT) x-ray source array. The goal is to improve the system spatial resolution by removing the x-ray tube motion induced focal spot blurring. The CNT x-ray source array comprises 31 individually addressable x-ray beams covering 30° angular span. Each x-ray beam has a minimum focal spot size of 0.64×0.61mm (full-width-at-half-maximum), a stationary W anode operating up to 50kVp, and 1mm thick Al filter. The flux from each beam is regulated and varied using dedicated control electronics. The maximum tube current is determined by the heat load of the stationary anode and depends on the energy, pulse width and the focal spot size used. Stable operation at 28kVp, 27mA tube current, 250msec pulse width and 38mA tube current, 183msec pulse width per exposure was achieved with extended lifetime. The standard ACR phantom was imaged and analyzed to evaluate the image quality. The actual scanning speed depends on the number of views and the readout time of the x-ray detector. With the present detector, 6 second scanning time at either 15 views or 31 views can be achieved at 100mAs total imaging dose with a detector readout time of 240msec.

  17. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  18. Improved superconducting magnet wire

    Science.gov (United States)

    Schuller, I.K.; Ketterson, J.B.

    1983-08-16

    This invention is directed to a superconducting tape or wire composed of alternating layers of copper and a niobium-containing superconductor such as niobium of NbTi, Nb/sub 3/Sn or Nb/sub 3/Ge. In general, each layer of the niobium-containing superconductor has a thickness in the range of about 0.05 to 1.5 times its coherence length (which for Nb/sub 3/Si is 41 A) with each copper layer having a thickness in the range of about 170 to 600 A. With the use of very thin layers of the niobium composition having a thickness within the desired range, the critical field (H/sub c/) may be increased by factors of 2 to 4. Also, the thin layers of the superconductor permit the resulting tape or wire to exhibit suitable ductility for winding on a magnet core. These compositions are also characterized by relatively high values of critical temperature and therefore will exhibit a combination of useful properties as superconductors.

  19. The performance characteristics of the Philips Gemini PET/CT scanner

    International Nuclear Information System (INIS)

    O'Keefe, G.J.; Papenfuss, A.T.; Scott, A.M.; Rowe, C.C.

    2002-01-01

    Full text: The Department of Nuclear Medicine, Centre for PET at the ARMC is commissioning a next generation PET/CT scanner based on gadolinium silicic dioxide (GSO) crystal technology to replace the BGO crystal PET scanner that has been in operation since 1992. The Gemini PET/CT scanner is a fully 3D PET system which offers significantly increased resolution and sensitivity allowing wholebody scans in under 30 minutes. Until the late 90's, PET scanners were largely used with septa for neurological imaging and the performance characteristics of PET scanners were presented according to the NEMA-NU2-94 standard which specifically addresses the performance of PET scanners for neurological applications. PET is now largely used without septa for oncological imaging and as such, the NEMA-NU2-94 standard does not adequately reflect performance. The NEMA-NU2-2001 standard was designed to incorporate the effects of out-of-FOV activity and its contribution to performance by virtue of the increased scatter and randoms that result when performing wholebody scans without the use of septa. As part of the acceptance program of the Allegro/Gemini systems, the NEMA-NU2-2001 standard will be used to characterise the spatial resolution, sensitivity, randoms and scatter contributions and the Noise Equivalent Count rate (NECr). These results will be presented and compared with the ECAT 951/31R performance characteristics. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  20. A multispectral scanner survey of the Rocky Flats Environmental Technology Site and surrounding area, Golden, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Brewster, S.B. Jr.; Brickey, D.W.; Ross, S.L.; Shines, J.E.

    1997-04-01

    Aerial multispectral scanner imagery was collected of the Rocky Flats Environmental Technology Site in Golden, Colorado, on June 3, 5, 6, and 7, 1994, using a Daedalus AADS1268 multispectral scanner and coincident aerial color and color infrared photography. Flight altitudes were 4,500 feet (1372 meters) above ground level to match prior 1989 survey data; 2,000 feet (609 meters) above ground level for sitewide vegetation mapping; and 1,000 feet (304 meters) above ground level for selected areas of special interest. A multispectral survey was initiated to improve the existing vegetation classification map, to identify seeps and springs, and to generate ARC/INFO Geographic Information System compatible coverages of the vegetation and wetlands for the entire site including the buffer zone. The multispectral scanner imagery and coincident aerial photography were analyzed for the detection, identification, and mapping of vegetation and wetlands. The multispectral scanner data were processed digitally while the color and color infrared photography were manually photo-interpreted to define vegetation and wetlands. Several standard image enhancement techniques were applied to the multispectral scanner data to assist image interpretation. A seep enhancement was applied and a color composite consisting of multispectral scanner channels 11, 7, and 5 (thermal infrared, mid-infrared, and red bands, respectively) proved most useful for detecting seeps, seep zones, and springs. The predawn thermal infrared data were also useful in identifying and locating seeps. The remote sensing data, mapped wetlands, and ancillary Geographic Information System compatible data sets were spatially analyzed for seeps.

  1. A multispectral scanner survey of the Rocky Flats Environmental Technology Site and surrounding area, Golden, Colorado

    International Nuclear Information System (INIS)

    Brewster, S.B. Jr.; Brickey, D.W.; Ross, S.L.; Shines, J.E.

    1997-04-01

    Aerial multispectral scanner imagery was collected of the Rocky Flats Environmental Technology Site in Golden, Colorado, on June 3, 5, 6, and 7, 1994, using a Daedalus AADS1268 multispectral scanner and coincident aerial color and color infrared photography. Flight altitudes were 4,500 feet (1372 meters) above ground level to match prior 1989 survey data; 2,000 feet (609 meters) above ground level for sitewide vegetation mapping; and 1,000 feet (304 meters) above ground level for selected areas of special interest. A multispectral survey was initiated to improve the existing vegetation classification map, to identify seeps and springs, and to generate ARC/INFO Geographic Information System compatible coverages of the vegetation and wetlands for the entire site including the buffer zone. The multispectral scanner imagery and coincident aerial photography were analyzed for the detection, identification, and mapping of vegetation and wetlands. The multispectral scanner data were processed digitally while the color and color infrared photography were manually photo-interpreted to define vegetation and wetlands. Several standard image enhancement techniques were applied to the multispectral scanner data to assist image interpretation. A seep enhancement was applied and a color composite consisting of multispectral scanner channels 11, 7, and 5 (thermal infrared, mid-infrared, and red bands, respectively) proved most useful for detecting seeps, seep zones, and springs. The predawn thermal infrared data were also useful in identifying and locating seeps. The remote sensing data, mapped wetlands, and ancillary Geographic Information System compatible data sets were spatially analyzed for seeps

  2. Development of Monte Carlo simulations to provide scanner-specific organ dose coefficients for contemporary CT.

    Science.gov (United States)

    Jansen, Jan T M; Shrimpton, Paul C

    2016-07-21

    The ImPACT (imaging performance assessment of CT scanners) CT patient dosimetry calculator is still used world-wide to estimate organ and effective doses (E) for computed tomography (CT) examinations, although the tool is based on Monte Carlo calculations reflecting practice in the early 1990's. Subsequent developments in CT scanners, definitions of E, anthropomorphic phantoms, computers and radiation transport codes, have all fuelled an urgent need for updated organ dose conversion factors for contemporary CT. A new system for such simulations has been developed and satisfactorily tested. Benchmark comparisons of normalised organ doses presently derived for three old scanners (General Electric 9800, Philips Tomoscan LX and Siemens Somatom DRH) are within 5% of published values. Moreover, calculated normalised values of CT Dose Index for these scanners are in reasonable agreement (within measurement and computational uncertainties of  ±6% and  ±1%, respectively) with reported standard measurements. Organ dose coefficients calculated for a contemporary CT scanner (Siemens Somatom Sensation 16) demonstrate potential deviations by up to around 30% from the surrogate values presently assumed (through a scanner matching process) when using the ImPACT CT Dosimetry tool for newer scanners. Also, illustrative estimates of E for some typical examinations and a range of anthropomorphic phantoms demonstrate the significant differences (by some 10's of percent) that can arise when changing from the previously adopted stylised mathematical phantom to the voxel phantoms presently recommended by the International Commission on Radiological Protection (ICRP), and when following the 2007 ICRP recommendations (updated from 1990) concerning tissue weighting factors. Further simulations with the validated dosimetry system will provide updated series of dose coefficients for a wide range of contemporary scanners.

  3. A Surface-Based Spatial Registration Method Based on Sense Three-Dimensional Scanner.

    Science.gov (United States)

    Fan, Yifeng; Xu, Xiufang; Wang, Manning

    2017-01-01

    The purpose of this study was to investigate the feasibility of a surface-based registration method based on a low-cost, hand-held Sense three-dimensional (3D) scanner in image-guided neurosurgery system. The scanner was calibrated prior and fixed on a tripod before registration. During registration, a part of the head surface was scanned at first and the spatial position of the adapter was recorded. Then the scanner was taken off from the tripod and the entire head surface was scanned by moving the scanner around the patient's head. All the scan points were aligned to the recorded spatial position to form a unique point cloud of the head by the automatic mosaic function of the scanner. The coordinates of the scan points were transformed from the device space to the adapter space by a calibration matrix, and then to the patient space. A 2-step patient-to-image registration method was then performed to register the patient space to the image space. The experimental results showed that the mean target registration error of 15 targets on the surface of the phantom was 1.61±0.09 mm. In a clinical experiment, the mean target registration error of 7 targets on the patient's head surface was 2.50±0.31 mm, which was sufficient to meet clinical requirements. It is feasible to use the Sense 3D scanner for patient-to-image registration, and the low-cost Sense 3D scanner can take the place of the current used scanner in the image-guided neurosurgery system.

  4. Development of Monte Carlo simulations to provide scanner-specific organ dose coefficients for contemporary CT

    Science.gov (United States)

    Jansen, Jan T. M.; Shrimpton, Paul C.

    2016-07-01

    The ImPACT (imaging performance assessment of CT scanners) CT patient dosimetry calculator is still used world-wide to estimate organ and effective doses (E) for computed tomography (CT) examinations, although the tool is based on Monte Carlo calculations reflecting practice in the early 1990’s. Subsequent developments in CT scanners, definitions of E, anthropomorphic phantoms, computers and radiation transport codes, have all fuelled an urgent need for updated organ dose conversion factors for contemporary CT. A new system for such simulations has been developed and satisfactorily tested. Benchmark comparisons of normalised organ doses presently derived for three old scanners (General Electric 9800, Philips Tomoscan LX and Siemens Somatom DRH) are within 5% of published values. Moreover, calculated normalised values of CT Dose Index for these scanners are in reasonable agreement (within measurement and computational uncertainties of  ±6% and  ±1%, respectively) with reported standard measurements. Organ dose coefficients calculated for a contemporary CT scanner (Siemens Somatom Sensation 16) demonstrate potential deviations by up to around 30% from the surrogate values presently assumed (through a scanner matching process) when using the ImPACT CT Dosimetry tool for newer scanners. Also, illustrative estimates of E for some typical examinations and a range of anthropomorphic phantoms demonstrate the significant differences (by some 10’s of percent) that can arise when changing from the previously adopted stylised mathematical phantom to the voxel phantoms presently recommended by the International Commission on Radiological Protection (ICRP), and when following the 2007 ICRP recommendations (updated from 1990) concerning tissue weighting factors. Further simulations with the validated dosimetry system will provide updated series of dose coefficients for a wide range of contemporary scanners.

  5. From barbed wire to radar traps

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Several million DM are required already to protect the building sites of power plants. From the very beginning concrete, wood, and barbed wire are used to make a protective wall against intruders, or in official German, 'unauthorized persons'. This expensive provisional set-up is later supplanted by electronic alarm and safety systems. A review of available systems helps to give a picture of power plant protection. (orig.) 891 HP [de

  6. Optical monitoring of scoliosis by 3D medical laser scanner

    Science.gov (United States)

    Rodríguez-Quiñonez, Julio C.; Sergiyenko, Oleg Yu.; Preciado, Luis C. Basaca; Tyrsa, Vera V.; Gurko, Alexander G.; Podrygalo, Mikhail A.; Lopez, Moises Rivas; Balbuena, Daniel Hernandez

    2014-03-01

    Three dimensional recording of the human body surface or anatomical areas have gained importance in many medical applications. In this paper, our 3D Medical Laser Scanner is presented. It is based on the novel principle of dynamic triangulation. We analyze the method of operation, medical applications, orthopedically diseases as Scoliosis and the most common types of skin to employ the system the most proper way. It is analyzed a group of medical problems related to the application of optical scanning in optimal way. Finally, experiments are conducted to verify the performance of the proposed system and its method uncertainty.

  7. Demonstration: A smartphone 3D functional brain scanner

    DEFF Research Database (Denmark)

    Stahlhut, Carsten; Stopczynski, Arkadiusz; Larsen, Jakob Eg

    We demonstrate a fully portable 3D real-time functional brain scanner consisting of a wireless 14-channel ‘Neuroheadset‘ (Emotiv EPOC) and a Nokia N900 smartphone. The novelty of our system is the ability to perform real-time functional brain imaging on a smartphone device, including stimulus...... tools are preferred. Source localization is implemented locally on the phone with a 3D brain model consisting of 1,028 vertices and 2,048 triangles stored in the mobile application. Our system design benefits from the possibility of being able to integrate with multiple hardware platforms (smartphones...

  8. A PC-controlled microwave tomographic scanner for breast imaging

    Science.gov (United States)

    Padhi, Shantanu; Howard, John; Fhager, A.; Bengtsson, Sebastian

    2011-01-01

    This article presents the design and development of a personal computer based controller for a microwave tomographic system for breast cancer detection. The system uses motorized, dual-polarized antennas and a custom-made GUI interface to control stepper motors, a wideband vector network analyzer (VNA) and to coordinate data acquisition and archival in a local MDSPlus database. Both copolar and cross-polar scattered field components can be measured directly. Experimental results are presented to validate the various functionalities of the scanner.

  9. Wire and Packing Tape Sandwiches

    Science.gov (United States)

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  10. Inter laboratory comparison of industrial CT scanners

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; Cantatore, Angela; De Chiffre, Leonardo

    2012-01-01

    In this report results from an intercomparison of industrial CT scanners are presented. Three audit items, similar to common industrial parts, were selected for circulation: a single polymer part with complex geometry (Item 1), a simple geometry part made of two polymers (Item 2) and a miniature ...

  11. A PET scanner developed by CERN

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    This image shows a Position Emission Tomography (PET) scanner at the Hopital Cantonal Universitaire de Genève. Development of the multiwire proportional chamber at CERN in the mid-1970s was soon seen as a potential device for medical imaging. It is much more sensitive than previous devices and greatly reduced the dose of radiation received by the patient.

  12. Scanner and irradiation: optimization of protocols

    International Nuclear Information System (INIS)

    Duchemin, J.; Martine-Rollet, B.; Lienart, S.; Mobailly, M.; Florin, J.P.; Beregi, J.P.; Puech, N.

    2006-01-01

    The irradiation of the patient or the personnel increased with the arrival of the multi-detector scanners. The objective of this work is to realize a didactic poster to inform and make sensitive on the irradiation with scan so that to propose solutions of protection. (N.C.)

  13. Wire metamaterials: physics and applications.

    Science.gov (United States)

    Simovski, Constantin R; Belov, Pavel A; Atrashchenko, Alexander V; Kivshar, Yuri S

    2012-08-16

    The physics and applications of a broad class of artificial electromagnetic materials composed of lattices of aligned metal rods embedded in a dielectric matrix are reviewed. Such structures are here termed wire metamaterials. They appear in various settings and can operate from microwaves to THz and optical frequencies. An important group of these metamaterials is a wire medium possessing extreme optical anisotropy. The study of wire metamaterials has a long history, however, most of their important and useful properties have been revealed and understood only recently, especially in the THz and optical frequency ranges where the wire media correspond to the lattices of microwires and nanowires, respectively. Another group of wire metamaterials are arrays and lattices of nanorods of noble metals whose unusual properties are driven by plasmonic resonances. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].

    Science.gov (United States)

    Zhang, J; Jiang, X Y; Huang, X W

    2016-06-18

    To investigate the clinical efficacy and outcomes of two separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella. From January 2013 to January 2015, 15 consecutive patients (mean age 54.5 years) with inferior pole fractures of the patella were retrospectively included in this study. All the patients underwent open reduction and internal fixation by separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire through longitudinal incision, 4.5 d (range: 3.1-5.9 d) after initial injury. A safety check for early knee range of motion was performed before wound closure. The complications including infection, nonunion, loss of fixation and any wire breakage or irritation from implant were recorded. Anteroposterior and lateral views of the knee joint obtained during the follow-up were used to assess bony union based on the time when the fracture line disappeared. At the time of the final outpatient follow up, functional evaluation of the knee joint was conducted by Bostman system. The follow-up time was 13.1 months (range: 12-19 months) after surgery on average, immediate motion without immobilization in all the cases was allowed and there was no case of reduction loss of the fracture and wire breakage. There was no case of irritation from the implant. At the final follow-up, the average range of motion (ROM) arc was 126.7° (range: 115°-140°), the average ROM lag versus contralateral healthy leg was 10.3° (range: 0°-35°). The mean Bostman score at the last follow-up was 28.9 (range: 27-30), and graded excellent in most cases. Two separate vertical wiring is an easy and effective method to reduce the displaced inferior pole fracture of patella. Augmentation of separate vertical wiring with tension band and Kirschner-wire plus cerclage wire in these patients provides enough strength to protected the early exercise of the knee joint and

  15. A PDMS-Based 2-Axis Waterproof Scanner for Photoacoustic Microscopy

    Directory of Open Access Journals (Sweden)

    Jin Young Kim

    2015-04-01

    Full Text Available Optical-resolution photoacoustic microscopy (OR-PAM is an imaging tool to provide in vivo optically sensitive images in biomedical research. To achieve a small size, fast imaging speed, wide scan range, and high signal-to-noise ratios (SNRs in a water environment, we introduce a polydimethylsiloxane (PDMS-based 2-axis scanner for a flexible and waterproof structure. The design, theoretical background, fabrication process and performance of the scanner are explained in details. The designed and fabricated scanner has dimensions of 15 × 15 × 15 mm along the X, Y and Z axes, respectively. The characteristics of the scanner are tested under DC and AC conditions. By pairing with electromagnetic forces, the maximum scanning angles in air and water are 18° and 13° along the X and Y axes, respectively. The measured resonance frequencies in air and water are 60 and 45 Hz along the X axis and 45 and 30 Hz along the Y axis, respectively. Finally, OR-PAM with high SNRs is demonstrated using the fabricated scanner, and the PA images of micro-patterned samples and microvasculatures of a mouse ear are successfully obtained with high-resolution and wide-field of view. OR-PAM equipped with the 2-axis PDMS based waterproof scanner has lateral and axial resolutions of 3.6 μm and 26 μm, respectively. This compact OR-PAM system could potentially and widely be used in preclinical and clinical applications.

  16. Large angle and high linearity two-dimensional laser scanner based on voice coil actuators.

    Science.gov (United States)

    Wu, Xin; Chen, Sihai; Chen, Wei; Yang, Minghui; Fu, Wen

    2011-10-01

    A large angle and high linearity two-dimensional laser scanner with an in-house ingenious deflection angle detecting system is developed based on voice coil actuators direct driving mechanism. The specially designed voice coil actuators make the steering mirror moving at a sufficiently large angle. Frequency sweep method based on virtual instruments is employed to achieve the natural frequency of the laser scanner. The response shows that the performance of the laser scanner is limited by the mechanical resonances. The closed-loop controller based on mathematical model is used to reduce the oscillation of the laser scanner at resonance frequency. To design a qualified controller, the model of the laser scanner is set up. The transfer function of the model is identified with MATLAB according to the tested data. After introducing of the controller, the nonlinearity decreases from 13.75% to 2.67% at 50 Hz. The laser scanner also has other advantages such as large deflection mirror, small mechanical structure, and high scanning speed.

  17. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    , therefore, we’ve drawn conclusions and recommendations for future editions of the event, also generalizable to other experiences of gamification especially in events. This report details the methodology and working elements from the design phase, human resources and organization of production......This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and have...... proposed new ones (viralization of the event on social networks and improvement of the integration of international attendees). On the other hand we defined a set of research objectives related to the study of gamification in an eminently social place like an event. Most of the goals have been met and...

  18. Body scanners: are they dangerous for health?; Scanners corporels: dangereux pour la sante?

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-07-01

    As there is a debate about the risk of cancer and of congenital malformation associated with the use of body scanners, notably in airports, this document recalls and comments the IAEA statement on this issue. According to a study performed by this international agency, the irradiation dose is very low. But the French IRSN is more prudent and recommends not to use X ray scanner, but to look for technologies which do not use ionizing radiation

  19. Cable pin system versus K-wire tension band fixation for patella fractures in Chinese Han population: A meta-analysis.

    Science.gov (United States)

    Zha, Kun; Liu, Guo-Hui; Yang, Shu-Hua; Zhou, Wu; Liu, Yi; Wu, Qi-Peng

    2017-10-01

    This meta-analysis compared the therapeutic effect of cable pin system (CPS) with K-wire tension band (KTB) in the treatment of patella fractures among Chinese Han population. The databases of PubMed, Cochrane library, China National Knowledge Infrastructure (CNKI), Chinese WanFang and Chinese VIP were searched for studies on CPS versus KTB in the treatment of patella fractures among Chinese Han population. Literatures were screened according to the inclusion and exclusion criteria. The quality of the studies was assessed, and meta-analysis was performed using the Cochrane Collaboration's REVMAN 5.3 software. A total of 932 patients from 15 studies were included in this meta-analysis (426 fractures treated with CPS and 506 fractures treated with KTB). There were significant differences in duration of hospital stay [mean difference (MD)=-1.07; 95% confidence interval (CI):-1.71 to-0.43], fracture healing time (MD=-1.23; 95% CI:-1.68 to-0.77), flexion degree of knee joint at 6th month after operation (MD=14.82; 95% CI: 10.93 to 18.71), incidence of postoperative complication [risk ratio (RR)=0.16; 95% CI: 0.09 to 0.27] and excellent-good rate of Böstman score (RR=1.09; 95% CI: 1.03 to 1.16) between the CPS group and KTB group, while no significant difference was found in operative time between the two groups (MD=-4.52; 95% CI:-11.70 to 2.67). For the treatment of patella fractures among Chinese Han population, limited evidence suggests that the CPS is more suitable than the KTB when considering the hospital stay, fracture healing time, flexion degree of knee at 6th month after operation, incidence of postoperative complication and excellent-good rate of Böstman joint score. Due to the limitation of high quality evidence and sample size, more large-scale randomized controlled trials are needed to validate the findings in the future.

  20. Occurrence and characteristics of mutual interference between LIDAR scanners

    Science.gov (United States)

    Kim, Gunzung; Eom, Jeongsook; Park, Seonghyeon; Park, Yongwan

    2015-05-01

    The LIDAR scanner is at the heart of object detection of the self-driving car. Mutual interference between LIDAR scanners has not been regarded as a problem because the percentage of vehicles equipped with LIDAR scanners was very rare. With the growing number of autonomous vehicle equipped with LIDAR scanner operated close to each other at the same time, the LIDAR scanner may receive laser pulses from other LIDAR scanners. In this paper, three types of experiments and their results are shown, according to the arrangement of two LIDAR scanners. We will show the probability that any LIDAR scanner will interfere mutually by considering spatial and temporal overlaps. It will present some typical mutual interference scenario and report an analysis of the interference mechanism.

  1. Temperature dependence of APD-based PET scanners

    International Nuclear Information System (INIS)

    Keereman, Vincent; Van Holen, Roel; Vandenberghe, Stefaan; Vanhove, Christian

    2013-01-01

    Purpose: Solid state detectors such as avalanche photodiodes (APDs) are increasingly being used in PET detectors. One of the disadvantages of APDs is the strong decrease of their gain factor with increasing ambient temperature. The light yield of most scintillation crystals also decreases when ambient temperature is increased. Both effects lead to considerable temperature dependence of the performance of APD-based PET scanners. In this paper, the authors propose a model for this dependence and the performance of the LabPET8 APD-based small animal PET scanner is evaluated at different temperatures.Methods: The model proposes that the effect of increasing temperature on the energy histogram of an APD-based PET scanner is a compression of the histogram along the energy axis. The energy histogram of the LabPET system was acquired at 21 °C and 25 °C to verify the validity of this model. Using the proposed model, the effect of temperature on system sensitivity was simulated for different detector temperature coefficients and temperatures. Subsequently, the effect of short term and long term temperature changes on the peak sensitivity of the LabPET system was measured. The axial sensitivity profile was measured at 21 °C and 24 °C following the NEMA NU 4-2008 standard. System spatial resolution was also evaluated. Furthermore, scatter fraction, count losses and random coincidences were evaluated at different temperatures. Image quality was also investigated.Results: As predicted by the model, the photopeak energy at 25 °C is lower than at 21 °C with a shift of approximately 6% per °C. Simulations showed that this results in an approximately linear decrease of sensitivity when temperature is increased from 21 °C to 24 °C and energy thresholds are constant. Experimental evaluation of the peak sensitivity at different temperatures showed a strong linear correlation for short term (2.32 kcps/MBq/°C = 12%/°C, R = −0.95) and long term (1.92 kcps/MBq/°C = 10%/

  2. A Study of Wire Breakup and In-Flight Particle Behavior During Wire Flame Spraying of Aluminum

    Science.gov (United States)

    Lunn, G. D.; Riley, M. A.; McCartney, D. G.

    2017-12-01

    Although wire flame spraying has been used for many years, there has been relatively little attention given to understanding the process dynamics. In this work, imaging of the molten wire tip, particle imaging using the Oseir SprayWatch system and particle capture (wipe tests) have all been employed to quantify plume behavior. Aluminum wire feedstock is melted and then breaks up close to the exit of the spray nozzle in a non-axisymmetric manor. The mean velocity and diameter of the particles detected by the SprayWatch system change little with standoff distance with values of approximately 280 m/s and 70 µm, respectively, for the spray parameters employed. The particle diagnostic system could not detect particles ⪅45 µm in diameter, and it is estimated that these account for no more than 53% of the sprayed material. Overall, wire flame spraying generates a surprisingly stable particle stream.

  3. An overview of NASA's digital fly-by-wire technology development program

    Science.gov (United States)

    Jarvis, C. R.

    1976-01-01

    The feasibility of using digital fly by wire systems to control aircraft was demonstrated by developing and flight testing a single channel system, which used Apollo hardware, in an F-8C test airplane. This is the first airplane to fly with a digital fly by wire system as its primary means of control and with no mechanical reversion capability. The development and flight test of a triplex digital fly by wire system, which will serve as an experimental prototype for future operational digital fly by wire systems, are underway.

  4. Applications of Optical Scanners in an Academic Center.

    Science.gov (United States)

    Molinari, Carol; Tannenbaum, Robert S.

    1995-01-01

    Describes optical scanners, including how the technology works; applications in data management and research; development of instructional materials; and providing community services. Discussion includes the three basic types of optical scanners: optical character recognition (OCR), optical mark readers (OMR), and graphic scanners. A sidebar…

  5. Structure of gold monoatomic wires connected to two electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Zoubkoff, Remi [Centre de Recherche en Matiere Condensee et Nanosciences, CNRS, Campus de Luminy, Case 913, 13288 Marseille Cedex 9 (France)]. E-mail: zoubkoff@crmcn.univ-mrs.fr; Vega, L. de la [Departamento de Fisica de la Materia Condensada C-V, Facultad de Ciencias, Universidad Autonoma de Madrid, E-28049 Madrid (Spain); Martin-Rodero, A. [Departamento de Fisica de la Materia Condensada C-V, Facultad de Ciencias, Universidad Autonoma de Madrid, E-28049 Madrid (Spain); Levy Yeyati, A. [Departamento de Fisica de la Materia Condensada C-V, Facultad de Ciencias, Universidad Autonoma de Madrid, E-28049 Madrid (Spain); Saul, Andres [Centre de Recherche en Matiere Condensee et Nanosciences, CNRS, Campus de Luminy, Case 913, 13288 Marseille Cedex 9 (France)

    2007-09-01

    In this work, we present calculations concerning the stability of infinite monoatomic Au wires and finite Au wires between electrodes. For the systems with the electrodes, that we represent by FCC slabs with (0 0 1) surfaces, the total energy calculations have been performed with a spd non-orthogonal tight-binding Hamiltonian. For the infinite wires, the calculations were also compared to semi-empirical and first principle ones. For the infinite wires and small enough inter-atomic distances, we find that a zig-zag structure is most stable than the linear one, in agreement with previous calculations. For the system between electrodes, one gets an almost concave or a symmetric broken edges structure depending on the inter-atomic distance.

  6. Imaging Scanner Usage in Radiochemical Purity Test

    International Nuclear Information System (INIS)

    Norhafizah Othman; Yahaya Talib; Wan Hamirul Bahrin Wan Kamal

    2011-01-01

    Imaging Scanner model BIOSCAN AR-2000 has been used in the radiochemical purity test for the product of Mo-99/ Tc-99m generator. Result from this test was produced directly where the percentage of pertechnetate was calculated based on width peak area by thin layer chromatography. This paperwork will explain the function, procedure, calibration of the instrument and discussed the advantages compared to the previous method. (author)

  7. Analysis of the Performance of a Laser Scanner for Predictive Automotive Applications

    Science.gov (United States)

    Zeisler, J.; Maas, H.-G.

    2015-08-01

    In this paper we evaluate the use of a laser scanner for future advanced driver assistance systems. We focus on the important task of predicting the target vehicle for longitudinal ego vehicle control. Our motivation is to decrease the reaction time of existing systems during cut-in maneuvers of other traffic participants. A state-of-the-art laser scanner, the Ibeo Scala B2 R , is presented, providing its sensing characteristics and the subsequent high level object data output. We evaluate the performance of the scanner towards object tracking with the help of a GPS real time kinematics system on a test track. Two designed scenarios show phases with constant distance and velocity as well as dynamic motion of the vehicles. We provide the results for the error in position and velocity of the scanner and furthermore, review our algorithm for target vehicle prediction. Finally we show the potential of the laser scanner with the estimated error, that leads to a decrease of up to 40% in reaction time with best conditions.

  8. Scanner-based macroscopic color variation estimation

    Science.gov (United States)

    Kuo, Chunghui; Lai, Di; Zeise, Eric

    2006-01-01

    Flatbed scanners have been adopted successfully in the measurement of microscopic image artifacts, such as granularity and mottle, in print samples because of their capability of providing full color, high resolution images. Accurate macroscopic color measurement relies on the use of colorimeters or spectrophotometers to provide a surrogate for human vision. The very different color response characteristics of flatbed scanners from any standard colorimetric response limits the utility of a flatbed scanner as a macroscopic color measuring device. This metamerism constraint can be significantly relaxed if our objective is mainly to quantify the color variations within a printed page or between pages where a small bias in measured colors can be tolerated as long as the color distributions relative to the individual mean values is similar. Two scenarios when converting color from the device RGB color space to a standardized color space such as CIELab are studied in this paper, blind and semi-blind color transformation, depending on the availability of the black channel information. We will show that both approaches offer satisfactory results in quantifying macroscopic color variation across pages while the semi-blind color transformation further provides fairly accurate color prediction capability.

  9. Particle discrimination by an automatic scanner for nuclear emulsion plates

    International Nuclear Information System (INIS)

    Heinecke, W.; Fischer, B.E.

    1976-01-01

    An automatic scanner for nuclear emulsion plates has been improved by adding particle discrimination. By determination of the mean luminosity of tracks in darkfield illumination in addition to the track length a clear discrimination has been obtained, at least for lighter particles. The scanning speed of the original automatic scanner has not been reduced. The scanner works up to 200 times faster than a human scanner. Besides the particle discrimination the determination of the mean track luminosity led to a lower perturbation sensitivity with respect to a high background of accidentally developed silvergrains, scratches in emulsion etc. The reproducibility of the results obtained by the automatic scanner is better than 5%. (Auth.)

  10. Modeling birds on wires.

    Science.gov (United States)

    Aydoğdu, A; Frasca, P; D'Apice, C; Manzo, R; Thornton, J M; Gachomo, B; Wilson, T; Cheung, B; Tariq, U; Saidel, W; Piccoli, B

    2017-02-21

    In this paper we introduce a mathematical model to study the group dynamics of birds resting on wires. The model is agent-based and postulates attraction-repulsion forces between the interacting birds: the interactions are "topological", in the sense that they involve a given number of neighbors irrespective of their distance. The model is first mathematically analyzed and then simulated to study its main properties: we observe that the model predicts birds to be more widely spaced near the borders of each group. We compare the results from the model with experimental data, derived from the analysis of pictures of pigeons and starlings taken in New Jersey: two different image elaboration protocols allow us to establish a good agreement with the model and to quantify its main parameters. We also discuss the potential handedness of the birds, by analyzing the group organization features and the group dynamics at the arrival of new birds. Finally, we propose a more refined mathematical model that describes landing and departing birds by suitable stochastic processes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Influence of magnetic moment formation on the conductance of coupled quantum wires

    International Nuclear Information System (INIS)

    Puller, V I; Mourokh, L G; Bird, J P; Ochiai, Y

    2005-01-01

    In this paper, we develop a model for the resonant interaction between a pair of coupled quantum wires, under conditions where self-consistent effects lead to the formation of a local magnetic moment in one of the wires. Our analysis is motivated by the experimental results of Morimoto et al (2003 Appl. Phys. Lett. 82 3952), who showed that the conductance of one of the quantum wires exhibits a resonant peak at low temperatures, whenever the other wire is swept into the regime where local-moment formation is expected. In order to account for these observations, we develop a theoretical model for the inter-wire interaction that calculated the transmission properties of one (the fixed) wire when the device potential is modified by the presence of an extra scattering term, arising from the presence of the local moment in the swept wire. To determine the transmission coefficients in this system, we derive equations describing the dynamics of electrons in the swept and fixed wires of the coupled-wire geometry. Our analysis clearly shows that the observation of a resonant peak in the conductance of the fixed wire is correlated to the appearance of additional structure (near 0.75 x 2e 2 /h or 0.25 x 2e 2 /h) in the conductance of the swept wire, in agreement with the experimental results of Morimoto et al

  12. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  13. Composite conductor containing superconductive wires

    Energy Technology Data Exchange (ETDEWEB)

    Larson, W.L.; Wong, J.

    1974-03-26

    A superconductor cable substitute made by coworking multiple rods of superconductive niobium--titanium or niobium--zirconium alloy with a common copper matrix to extend the copper and rods to form a final elongated product which has superconductive wires distributed in a reduced cross-section copper conductor with a complete metallurgical bond between the normal-conductive copper and the superconductor wires contained therein is described. The superconductor cable can be in the form of a tube.

  14. Disorder and Interaction Effects in Quantum Wires

    International Nuclear Information System (INIS)

    Smith, L W; Ritchie, D A; Farrer, I; Griffiths, J P; Jones, G A C; Thomas, K J; Pepper, M

    2012-01-01

    We present conductance measurements of quasi-one-dimensional quantum wires affected by random disorder in a GaAs/AlGaAs heterostructure. In addition to quantised conductance plateaux, we observe structure superimposed on the conductance characteristics when the channel is wide and the density is low. Magnetic field and temperature are varied to characterize the conductance features which depend on the lateral position of the 1D channel formed in a split-gate device. Our results suggest that there is enhanced backscattering in the wide channel limit, which gives rise to quantum interference effects. When the wires are free of disorder and wide, the confinement is weak so that the mutual repulsion of the electrons forces a single row to split into two. The relationship of this topological change to the disorder in the system will be discussed.

  15. 30 CFR 75.701-4 - Grounding wires; capacity of wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...

  16. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  17. Quality control of some CT scanners in Khartoum state

    International Nuclear Information System (INIS)

    Yousif, Ali Mohammed Ali

    2013-06-01

    This study conduced with the aim to evaluate the performance of three CT scanner in Khartoum-Sudan through extensive quality control measurements. Image quality was assessed using a CATPHAN 412 CT image quality phantom. Image quality parameters evaluated were: CT image noise, uniformity, CT number linearity, Low Contrast Resolution, High Contrast Resolution, measurements were performed in accordance with guidelines set out by the Institute of physical science and engineering in medicine (IPEM 91). Image quality parameters tested were within the apoplectic limit specified in the relevant CT guidelines. Measured slice thickness ranged between 9.66-10.5 mm for large slice and 5.25-5.88 for medium slice. The correlation coefficient (R) between the measured and the reference CT number was better than 0.99 for all CT scanners. High resolution for large slice was 7 L P/ cm and 8 L P/ cm for small slice. Low contrast resolution with 1.0% nominal level ranged between 2-3 mm diameter of disc for large slice and 4-7 mm diameter disc for small slice. The measured noise ranged between 1.4-3.4 HU for large slice and 2.92-4.08 HU for small slice. Uniformity ranged between 3.08 to 2.075 HU for large slice and 3.22 to 1.4 HU for small slice thickness. The results indicate that routine maintenance, service and calibration, as well as the frequent quality control of CT scanners play a key rote in achieving the best performance of the system. Since computed tomography (CT) contributes the most to the collective dose compared to other radiological examinations, it is a necessity for quality control and quality assurance programs to be established in each radiology department.(Author)

  18. Survey of damage to 602 MR scanners after the Great East Japan Earthquake

    International Nuclear Information System (INIS)

    Nakai, Toshiharu; Yamaguchi-Sekino, Sachiko; Tsuchihashi, Toshio

    2013-01-01

    An earthquake of 9.0 magnitude, the largest in modern Japanese history, struck east Japan on March 11, 2011. We investigated hazards and observations related to magnetic resonance (MR) scanners in this earthquake to evaluate potential risks and consider further prevention or minimization of damage from and injury of patients in such large earthquakes. The investigation team funded by MHLW sent questionnaires to the 984 facilities with installed MR scanners in the 7 prefectures of east Japan (Iwate, Miyagi, Fukushima, Ibaraki, Chiba, Tokyo, Saitama) and collected 458 responses (46.6%) with information on 602 MR scanners (144 units≤0.5 tesla; 31 one-T units; 371 1.5-T units; and 56 units≥3 T). Significant differences in damage were observed between seismic scale 5 and 6 (χ 2 test, P<0.001 for all items of damage checked). The frequencies of typical damage were displacement of magnets (12.4%), failure of the chiller or air conditioning (9.6%), rapid decrease in liquid helium (8.4%), damage to magnet enclosure and its equipment (7.6%), damage to shielding of the MR scanner room (6.1%), damage to the quench duct (4.5%), breakage of devices anchoring system cabinets (4.4%), damage to the magnet base (3.9%), and flying of metal components (1.5%). Twelve facilities reported flooding by the subsequent tsunami, and quench was confirmed in 19 facilities. No fire damage was reported. It was confirmed that no one was severely injured in MR scanners, and base isolation of the building was very useful in completely preventing damage even at seismic scale 7. In the future, training for evacuation and establishment of a standard protocol for emergency shutdown of MR scanners, onsite checking by MR operators, and emergency power plant equipment to maintain chiller for MR scanners will further ensure MR safety in an earthquake. (author)

  19. Automatic Channel Fault Detection on a Small Animal APD-Based Digital PET Scanner

    Science.gov (United States)

    Charest, Jonathan; Beaudoin, Jean-François; Cadorette, Jules; Lecomte, Roger; Brunet, Charles-Antoine; Fontaine, Réjean

    2014-10-01

    Avalanche photodiode (APD) based positron emission tomography (PET) scanners show enhanced imaging capabilities in terms of spatial resolution and contrast due to the one to one coupling and size of individual crystal-APD detectors. However, to ensure the maximal performance, these PET scanners require proper calibration by qualified scanner operators, which can become a cumbersome task because of the huge number of channels they are made of. An intelligent system (IS) intends to alleviate this workload by enabling a diagnosis of the observational errors of the scanner. The IS can be broken down into four hierarchical blocks: parameter extraction, channel fault detection, prioritization and diagnosis. One of the main activities of the IS consists in analyzing available channel data such as: normalization coincidence counts and single count rates, crystal identification classification data, energy histograms, APD bias and noise thresholds to establish the channel health status that will be used to detect channel faults. This paper focuses on the first two blocks of the IS: parameter extraction and channel fault detection. The purpose of the parameter extraction block is to process available data on individual channels into parameters that are subsequently used by the fault detection block to generate the channel health status. To ensure extensibility, the channel fault detection block is divided into indicators representing different aspects of PET scanner performance: sensitivity, timing, crystal identification and energy. Some experiments on a 8 cm axial length LabPET scanner located at the Sherbrooke Molecular Imaging Center demonstrated an erroneous channel fault detection rate of 10% (with a 95% confidence interval (CI) of [9, 11]) which is considered tolerable. Globally, the IS achieves a channel fault detection efficiency of 96% (CI: [95, 97]), which proves that many faults can be detected automatically. Increased fault detection efficiency would be

  20. Scanner component and head development for confocal microscopy using moving mirror technology

    Science.gov (United States)

    Loney, Gregory C.

    1993-12-01

    One of the challenges in designing a confocal microscope is choosing the scan system configuration. The selection is based largely on the microscope application and involves a few distinct schemes. One scheme, moving mirror using galvanometer and resonant scanners, has been shown to offer an excellent solution exhibited by the large number of commercial systems which utilize them. Perceived shortcomings, such as slow image acquisition, are being dispelled due to the advent of large angle, high frequency resonant scanners. These newer devices offer near video rate performance at good scan efficiency.

  1. Improved Scanners for Microscopic Hyperspectral Imaging

    Science.gov (United States)

    Mao, Chengye

    2009-01-01

    Improved scanners to be incorporated into hyperspectral microscope-based imaging systems have been invented. Heretofore, in microscopic imaging, including spectral imaging, it has been customary to either move the specimen relative to the optical assembly that includes the microscope or else move the entire assembly relative to the specimen. It becomes extremely difficult to control such scanning when submicron translation increments are required, because the high magnification of the microscope enlarges all movements in the specimen image on the focal plane. To overcome this difficulty, in a system based on this invention, no attempt would be made to move either the specimen or the optical assembly. Instead, an objective lens would be moved within the assembly so as to cause translation of the image at the focal plane: the effect would be equivalent to scanning in the focal plane. The upper part of the figure depicts a generic proposed microscope-based hyperspectral imaging system incorporating the invention. The optical assembly of this system would include an objective lens (normally, a microscope objective lens) and a charge-coupled-device (CCD) camera. The objective lens would be mounted on a servomotor-driven translation stage, which would be capable of moving the lens in precisely controlled increments, relative to the camera, parallel to the focal-plane scan axis. The output of the CCD camera would be digitized and fed to a frame grabber in a computer. The computer would store the frame-grabber output for subsequent viewing and/or processing of images. The computer would contain a position-control interface board, through which it would control the servomotor. There are several versions of the invention. An essential feature common to all versions is that the stationary optical subassembly containing the camera would also contain a spatial window, at the focal plane of the objective lens, that would pass only a selected portion of the image. In one version

  2. Eliminating a Major Cause of Wire Drawing Breakage in A-15 High-Field Superconductors

    International Nuclear Information System (INIS)

    Austen, Alfred R.

    2003-01-01

    Eliminating a Major Cause of Wire Drawing Breakage in A-15 High-Field Superconductors Phase 1 Summary Purpose of the research: The Phase 1 goal was to make a significant improvement in the wire drawing technology used for difficult to draw superconductor precursor composites. Many ductile Nb-Al and Nb-Sn precursor wire composites have experienced the onset of wire drawing breakage at about 1.5 mm diameter. Phase 1 focused on evaluating the role that precision rigid guidance of the wire into the drawing die and the hydrostatic stress state at the die entrance played in preventing wire breakage. Research carried out: The research performed depended upon the construction of both a mechanical wire guide and a hydrostatic pressure stiffened wire guidance system. Innovare constructed the two wire guidance systems and tested them for their ability to reduce wire drawing breakage. One set of hardware provided rigid alignment of the wires to their wire drawing die axes within 0.35 degrees using ''hydrostatic pressure stiffening'' to enable the precision guidance strategy to be implemented for these highly flexible small diameter wires. This apparatus was compared to a guide arrangement that used short span mechanical guide alignment with a misalignment limit of about 0.75 degrees. Four A-15 composite wires with breakage histories were drawn to evaluate the use of these wire guiding systems to reduce and/or eliminate wire breakage. Research findings and results: In Phase 1, a breakthrough in wire drawing technology for A-15 superconductor composites was achieved by dramatically limiting or eliminating breakage in four different A-15 composite precursor wire designs during the drawing of these very desirable composites that previously could not be drawn to near final size. Research results showed that the proposed Phase 1 mechanical wire guides were sufficiently effective and successful in eliminating breakage when used along with other advanced wire drawing technology to

  3. Initial clinical test of a breast-PET scanner.

    Science.gov (United States)

    Raylman, Raymond R; Abraham, Jame; Hazard, Hannah; Koren, Courtney; Filburn, Shannon; Schreiman, Judith S; Kurian, Sobha; Majewski, Stan; Marano, Gary D

    2011-02-01

    The goal of this initial clinical study was to test a new positron emission/tomography imager and biopsy system (PEM/PET) in a small group of selected subjects to assess its clinical imaging capabilities. Specifically, the main task of this study is to determine whether the new system can successfully be used to produce images of known breast cancer and compare them to those acquired by standard techniques. The PEM/PET system consists of two pairs of rotating radiation detectors located beneath a patient table. The scanner has a spatial resolution of ∼2 mm in all three dimensions. The subjects consisted of five patients diagnosed with locally advanced breast cancer ranging in age from 40 to 55 years old scheduled for pre-treatment, conventional whole body PET imaging with F-18 Fluorodeoxyglucose (FDG). The primary lesions were at least 2 cm in diameter. The images from the PEM/PET system demonstrated that this system is capable of identifying some lesions not visible in standard mammograms. Furthermore, while the relatively large lesions imaged in this study where all visualised by a standard whole body PET/CT scanner, some of the morphology of the tumours (ductal infiltration, for example) was better defined with the PEM/PET system. Significantly, these images were obtained immediately following a standard whole body PET scan. The initial testing of the new PEM/PET system demonstrated that the new system is capable of producing good quality breast-PET images compared standard methods. © 2011 The Authors. Journal of Medical Imaging and Radiation Oncology © 2011 The Royal Australian and New Zealand College of Radiologists.

  4. Molecular wires, switches and memories

    Science.gov (United States)

    Chen, Jia

    Molecular electronics, an emerging field, makes it possible to build individual molecules capable of performing functions identical or analogous to present- day conductors, switches, or memories. These individual molecules, with a nano-meter scale characteristic length, can be designed and chemically synthesized with specific atoms, geometries and charge distribution. This thesis focuses on the design, and measurements of molecular wires, and related strategically engineered structures-molecular switches and memories. The experimental system relies on a thermodynamically driven self-assembling process to attach molecules onto substrate surfaces without intervention from outside. The following topics will be discussed: directed nanoscale manipulation of self-assembled molecules using scanning tunneling microscope; investigation on through-bond transport of nanoscale symmetric metal/conjugated self- assembled monolayers (SAM)/metal junctions, where non- Ohmic thermionic emission was observed to be the dominant process, with isocyanide-Pd contacts showing the lowest thermionic barrier of 0.22 eV; the first realization of robust and large reversible switching behavior in an electronic device that utilizes molecules containing redox centers as the active component, exhibiting negative differential resistance (NDR) and large on-off peak-to-valley ratio (PVR); observation of erasable storage of higher conductivity states in these redox- center containing molecular devices, and demonstration of a two-terminal electronically programmable and erasable molecular memory cell with long bit retention time.

  5. Laser Scanner 3D Applicazioni, metodologie e potenzialità del rilevamento con laser scanner terrestre

    Directory of Open Access Journals (Sweden)

    Giorgio Vassena

    2007-03-01

    Full Text Available Con un po’ di ritardo riportiamo il resoconto della giornata che si è svolta lo scorso 28 maggio presso l’Università degli Studi di Brescia dedicata al laser scanner terrestre. Con l’intervento di geologi, tecnici, ingegneri e accademici sono stati analizzati casi pratici e concreti in cui l’integrazione del laser scanner con le tecniche di rilevamento classico (fotografiche, topografichee GPS è stata fondamentale per la riuscita finale del lavoro.

  6. Wired and Wireless Camera Triggering with Arduino

    Science.gov (United States)

    Kauhanen, H.; Rönnholm, P.

    2017-10-01

    Synchronous triggering is an important task that allows simultaneous data capture from multiple cameras. Accurate synchronization enables 3D measurements of moving objects or from a moving platform. In this paper, we describe one wired and four wireless variations of Arduino-based low-cost remote trigger systems designed to provide a synchronous trigger signal for industrial cameras. Our wireless systems utilize 315 MHz or 434 MHz frequencies with noise filtering capacitors. In order to validate the synchronization accuracy, we developed a prototype of a rotating trigger detection system (named RoTriDeS). This system is suitable to detect the triggering accuracy of global shutter cameras. As a result, the wired system indicated an 8.91 μs mean triggering time difference between two cameras. Corresponding mean values for the four wireless triggering systems varied between 7.92 and 9.42 μs. Presented values include both camera-based and trigger-based desynchronization. Arduino-based triggering systems appeared to be feasible, and they have the potential to be extended to more complicated triggering systems.

  7. Compact photographic film scanner with linear density digital display

    International Nuclear Information System (INIS)

    Pal, N.C.; Sankaran, A.; Gangadharan, P.

    1979-01-01

    The film scanning probe has been found very convenient mounted on a platform for scanning exposed films of various sizes. This device offers a rapid method to measure the various parameters of a radiation field used in radiotherapy such as beam profile in air as well as in phantom, central axis depth dose, isodose distributions etc. The measuring system has good precision and can measure densities up to 4 with a resolution of 0.01. The power consumed by the system is less than 100 mW. The digital measuring system facilitates easy processing and computerization of density data. A complete fully-automatic digital film scanner is planned using stepping motors to move the probe in the X and Y directions and a microprocessor for control and data processing. Further work along this line is in progress. (auth.)

  8. The TT-PET project: a thin TOF-PET scanner based on fast novel silicon pixel detectors

    Science.gov (United States)

    Bandi, Y.; Benoit, M.; Cadoux, F. R.; Forshaw, D. C.; Hänni, R.; Hayakawa, D.; Iacobucci, G.; Michal, S.; Miucci, A.; Paolozzi, L.; Ratib, O.; Ripiccini, E.; Tognina, C.; Valerio, P.; Weber, M.

    2018-01-01

    The TT-PET project aims at developing a compact Time-of-flight PET scanner with 30ps time resolution, capable of withstanding high magnetic fields and allowing for integration in a traditional MRI scanner, providing complimentary real-time PET images. The very high timing resolution of the TT-PET scanner is achieved thanks to a new generation of Silicon-Germanium (Si-Ge) amplifiers, which are embedded in monolithic pixel sensors. The scanner is composed of 16 detection towers as well as cooling blocks, arranged in a ring structure. The towers are composed of multiple ultra-thin pixel modules stacked on top of each other. Making it possible to perform depth of interaction measurements and maximize the spatial resolution along the line of flight of the two photons emitted within a patient. This will result in improved image quality, contrast, and uniformity while drastically reducing backgrounds within the scanner. Allowing for a reduction in the amount of radioactivity delivered to the patient. Due to an expected data rate of about 250 MB/s a custom readout system for high data throughput has been developed, which includes noise filtering and reduced data pressure. The realisation of a first scanner prototype for small animals is foreseen by 2019. A general overview of the scanner will be given including, technical details concerning the detection elements, mechanics, DAQ readout, simulation and results.

  9. MR-compatible and conventional localization wires in breast diagnosis: experimental studies on the dislocation and artefact size in MRI

    International Nuclear Information System (INIS)

    Langen, H.J.; Walter, C.; Ernst, S.; Kugel, H.; Lackner, K.

    1999-01-01

    Purpose: Localization of non-palpable suspicious breast lesions with tumor localization wires is commonly used before surgical excision. Dislocation of the wire is possible. The possibility of dislocation for different types of tumor localization wires was examined experimentally. Results: The localization wires with an X-configuration and long hook could not be dislocated by a force up to the maximum of 12 Newton. The retractable localization wires were easily dislocated at traction forces of 1 Newton. Other wires with only one hook could withstand a traction from 2 up to 7 Newton. The wires with a Z-configuration and wires with short hooks showed a highly variable rate of resistance. The artifact size of localization systems was between 10.1 and 11.0 mm for gradient-echo sequences and between 6.7 and 7.1 mm for spin-echo sequences. (orig.) [de

  10. Label-free tissue scanner for colorectal cancer screening

    Science.gov (United States)

    Kandel, Mikhail E.; Sridharan, Shamira; Liang, Jon; Luo, Zelun; Han, Kevin; Macias, Virgilia; Shah, Anish; Patel, Roshan; Tangella, Krishnarao; Kajdacsy-Balla, Andre; Guzman, Grace; Popescu, Gabriel

    2017-06-01

    The current practice of surgical pathology relies on external contrast agents to reveal tissue architecture, which is then qualitatively examined by a trained pathologist. The diagnosis is based on the comparison with standardized empirical, qualitative assessments of limited objectivity. We propose an approach to pathology based on interferometric imaging of "unstained" biopsies, which provides unique capabilities for quantitative diagnosis and automation. We developed a label-free tissue scanner based on "quantitative phase imaging," which maps out optical path length at each point in the field of view and, thus, yields images that are sensitive to the "nanoscale" tissue architecture. Unlike analysis of stained tissue, which is qualitative in nature and affected by color balance, staining strength and imaging conditions, optical path length measurements are intrinsically quantitative, i.e., images can be compared across different instruments and clinical sites. These critical features allow us to automate the diagnosis process. We paired our interferometric optical system with highly parallelized, dedicated software algorithms for data acquisition, allowing us to image at a throughput comparable to that of commercial tissue scanners while maintaining the nanoscale sensitivity to morphology. Based on the measured phase information, we implemented software tools for autofocusing during imaging, as well as image archiving and data access. To illustrate the potential of our technology for large volume pathology screening, we established an "intrinsic marker" for colorectal disease that detects tissue with dysplasia or colorectal cancer and flags specific areas for further examination, potentially improving the efficiency of existing pathology workflows.

  11. Wiring cost and topological participation of the mouse brain connectome.

    Science.gov (United States)

    Rubinov, Mikail; Ypma, Rolf J F; Watson, Charles; Bullmore, Edward T

    2015-08-11

    Brain connectomes are topologically complex systems, anatomically embedded in 3D space. Anatomical conservation of "wiring cost" explains many but not all aspects of these networks. Here, we examined the relationship between topology and wiring cost in the mouse connectome by using data from 461 systematically acquired anterograde-tracer injections into the right cortical and subcortical regions of the mouse brain. We estimated brain-wide weights, distances, and wiring costs of axonal projections and performed a multiscale topological and spatial analysis of the resulting weighted and directed mouse brain connectome. Our analysis showed that the mouse connectome has small-world properties, a hierarchical modular structure, and greater-than-minimal wiring costs. High-participation hubs of this connectome mediated communication between functionally specialized and anatomically localized modules, had especially high wiring costs, and closely corresponded to regions of the default mode network. Analyses of independently acquired histological and gene-expression data showed that nodal participation colocalized with low neuronal density and high expression of genes enriched for cognition, learning and memory, and behavior. The mouse connectome contains high-participation hubs, which are not explained by wiring-cost minimization but instead reflect competitive selection pressures for integrated network topology as a basis for higher cognitive and behavioral functions.

  12. Mapping soil features from multispectral scanner data

    Science.gov (United States)

    Kristof, S. J.; Zachary, A. L.

    1974-01-01

    In being able to identify quickly gross variations in soil features, the computer-aided classification of multispectral scanner data can be an effective aid to soil surveying. Variations in soil tone are easily seen as well as variations in features related to soil tone, e.g., drainage patterns and organic matter content. Changes in surface texture also affect the reflectance properties of soils. Inasmuch as conventional soil classes are based on both surface and subsurface soil characteristics, the technique described here can be expected only to augment and not replace traditional soil mapping.

  13. A digital fly-by-wire technology development program using an F-8C test aircraft

    Science.gov (United States)

    Jarvis, C. R.

    1974-01-01

    A digital fly-by-wire flight control system has been installed in an F-8C test airplane and has undergone extensive ground and flight testing as part of an overall program to develop digital fly-by-wire technology. This is the first airplane to fly with a digital fly-by-wire system as its primary means of control and with no mechanical reversion capability. Forty-two test flights were made for a total flight time of 57 hours. Six pilots participated in the evaluation. This paper presents an overview of the digital fly-by-wire program and discusses some of the flight-test results.

  14. Impacts of Intelligent Automated Quality Control on a Small Animal APD-Based Digital PET Scanner

    Science.gov (United States)

    Charest, Jonathan; Beaudoin, Jean-François; Bergeron, Mélanie; Cadorette, Jules; Arpin, Louis; Lecomte, Roger; Brunet, Charles-Antoine; Fontaine, Réjean

    2016-10-01

    Stable system performance is mandatory to warrant the accuracy and reliability of biological results relying on small animal positron emission tomography (PET) imaging studies. This simple requirement sets the ground for imposing routine quality control (QC) procedures to keep PET scanners at a reliable optimal performance level. However, such procedures can become burdensome to implement for scanner operators, especially taking into account the increasing number of data acquisition channels in newer generation PET scanners. In systems using pixel detectors to achieve enhanced spatial resolution and contrast-to-noise ratio (CNR), the QC workload rapidly increases to unmanageable levels due to the number of independent channels involved. An artificial intelligence based QC system, referred to as Scanner Intelligent Diagnosis for Optimal Performance (SIDOP), was proposed to help reducing the QC workload by performing automatic channel fault detection and diagnosis. SIDOP consists of four high-level modules that employ machine learning methods to perform their tasks: Parameter Extraction, Channel Fault Detection, Fault Prioritization, and Fault Diagnosis. Ultimately, SIDOP submits a prioritized faulty channel list to the operator and proposes actions to correct them. To validate that SIDOP can perform QC procedures adequately, it was deployed on a LabPET™ scanner and multiple performance metrics were extracted. After multiple corrections on sub-optimal scanner settings, a 8.5% (with a 95% confidence interval (CI) of [7.6, 9.3]) improvement in the CNR, a 17.0% (CI: [15.3, 18.7]) decrease of the uniformity percentage standard deviation, and a 6.8% gain in global sensitivity were observed. These results confirm that SIDOP can indeed be of assistance in performing QC procedures and restore performance to optimal figures.

  15. Radiation exposure and privacy concerns surrounding full-body scanners in airports

    Directory of Open Access Journals (Sweden)

    Julie Accardo

    2014-04-01

    Full Text Available Millions of people filter through airport security check points in the United States every year. These security checks, in response to the post 9/11 and 2009 “Underwear Bomber” terrorist threats, have become increasingly burdensome to the general public due to the wide spread deployment of “enhanced screening systems.” The enhanced screening systems that have generated the most controversy are the passenger “full-body scanners.” These systems enable airport security personnel to effectively detect contraband (often concealed under clothing without the physical contact necessitated by a strip search. The two types of full-body scanners (also known as Advanced Imaging Technology systems, used in airports in the United States and around the world are referred to as backscatter technology units and millimeter-wave technology units. Although their respective radiation emissions vary, both scanners serve the same purpose; that is, the detection of concealed metallic and non-metallic threats in the form of liquids, gels, plastics, etc. Although enhanced screening systems were deployed to further public safety efforts, they have also generated wide spread public concern. Specifically, these concerns address the potential of adverse health and privacy issues that may result from continued public exposure to full-body scanner systems.

  16. NUMERICAL MODELING AND INVESTIGATION OF CONTACT FRICTION INFLUENCE ON THERMAL FIELDS DISTRIBUTION AND DEFLECTED MODE IN STEEL WIRE AT HIGH-SPEED WIRE DRAWING

    Directory of Open Access Journals (Sweden)

    M. N. Vereshchagin

    2009-01-01

    Full Text Available The appraisal of  character of  the temperature fields distribution in dies at their interactions in the processes of  wire drawing in dependence on contact friction in conditions of  the system wire-die is given.

  17. Migration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report.

    Science.gov (United States)

    Aydın, Ekrem; Dülgeroğlu, Turan Cihan; Metineren, Hasan

    2016-02-24

    Patella fractures represent 1 % of all musculoskeletal system fractures. Fixation of patellar fractures using open reduction and tension band wiring is a commonly used and successful surgical fixation method. A 28-year-old male patient from Turkey presented to our clinic with complaints of palpable foreign bodies under the skin on the dorsolateral side of his right foot. Except for the palpable and moving body of about 6 cm length under the skin in his foot, he had no functional complaints. On X-ray, a Kirschner wire was visible in front of the lateral malleolus on the dorsolateral side of his right foot. In addition, there was a cerclage wire from the tension band fixation of his patella in the ipsilateral knee. The Kirschner wire was removed surgically. Despite the use of different fixation materials for the surgical treatment of patellar fractures, tension band wiring is still a commonly used technique. We recommend that after fixation of a patellar fracture using the tension band wiring technique, the ends of the Kirschner wires be bent and the wires then removed in the early phase after patellar union to prevent Kirschner wire migration.

  18. High hydrogen loading of thin palladium wires through alkaline earth carbonates' precipitation on the cathodic surface - evidence of a new phase in the Pd-H system

    Energy Technology Data Exchange (ETDEWEB)

    Celani, F.; Spallone, A.; Di Gioacchino, D. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, Frascati, RM (Italy); Marini, P.; Di Stefano, V.; Nakamura, M. [EURESYS, Rome (Italy); Pace, S. [Salerno Univ., Salerno (Italy). Dept. of Physics, Istituto Nazionale per la Fisica della Materia; Mancini, A. [ORIM S.r.l., Piediripa, MC (Italy); Tripodi, P. [Stanford Research Institut International, Stanford, CA (United States)

    2000-07-01

    A new protocol for the electrolytic loading of hydrogen (H) in thin palladium (Pd) wires has been developed. In order to increase the cathodic overvoltage, which is known to be the main parameter capable to enhance the electrolytic H loading of Pd, the catalytic action of the Pd surface versus H-H recombination has been strongly reduced by precipitation of a thin layer of alkaline-earth carbonates on the cathode. A set of electrolytes has been employed, containing small amounts of hydrochloric or sulfuric acid and strontium or calcium ions. The H loading has been continuously evaluated through ac measurements of the Pd wire resistance. Uncommonly low resistivity values, leading to an estimate of exceptionally high H loading, have been observed. Evidence of the existence of a new phase in the very high H content region of the Pd-H system has been inferred on the basis of the determination of the temperature coefficient of the electrical resistivity. Mainly for this purpose a thin layer of Hg was galvanically deposed on the cathodic surface, in order to prevent any H deloading during the measurements. The results have been fully reproduced in other 2 well equipped and experienced Laboratories (Italy, USA).

  19. FY 1998 result report on development of superconductive power application technologies. Pt. 1. Research and development of superconductive wire materials / Research of a total system / Research and development of a freezing system / Demonstration tests; 1998 nendo chodendo denryoku oyo gijutsu kaihatsu. 1. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Superconductive technologies are introduced into electric power devices for attempts of achieving higher stabilization, density and efficiency, as well as size and weight reduction and improvement in performance of the devices. The project has been worked on since fiscal 1998 as part of the New Sunshine Project. Fiscal 1998 being the eleventh year has taken the following subjects as the research promotion policies: establishment of plans targeted at accomplishment of the goals of the project; adequate and reliable implementation of verification of technological assignments; and steady and efficient demonstration tests. Subsequent to the previous year during which site demonstration tests were completed on a low-speed responsive model machine, the site demonstration test has begun on the ultra high-speed responsive model machine as the final stage of the project. The ultra high-speed responsive model machine was coupled with a freezing system and a load synchronizing machine, and different kinds of test were carried out where good results were obtained. Researches were conducted on characteristics improvement and device element technologies aimed at achieving the practical application level by utilizing the respective features of AC metal-based wires and oxide-based wires, where sound results were obtained. Also in an improved freezing system, valuable data were attained as part of establishing the basic technologies for a superconductive power generation system. (NEDO)

  20. Detection of analyte binding to microarrays using gold nanoparticle labels and a desktop scanner

    DEFF Research Database (Denmark)

    Han, Anpan; Dufva, Martin; Belleville, Erik

    2003-01-01

    six attomoles of antibody-gold conjugates. This detection system was used in a competitive immunoassay to measure the concentration of the pesticide metabolite 2,6-dichlorobenzamide (BAM) in water samples. The results showed that the gold labeled antibodies functioned comparably with a fluorescent......Microarray hybridization or antibody binding can be detected by many techniques, however, only a few are suitable for widespread use since many of these detection techniques rely on bulky and expensive instruments. Here, we describe the usefulness of a simple and inexpensive detection method based...... on gold nanoparticle labeled antibodies visualized by a commercial, office desktop flatbed scanner. Scanning electron microscopy studies showed that the signal from the flatbed scanner was proportional to the surface density of the bound antibody-gold conjugates, and that the flatbed scanner could detect...

  1. Conceptual study of Earth observation missions with a space-borne laser scanner

    Science.gov (United States)

    Kobayashi, Takashi; Sato, Yohei; Yamakawa, Shiro

    2017-11-01

    The Japan Aerospace Exploration Agency (JAXA) has started a conceptual study of earth observation missions with a space-borne laser scanner (GLS, as Global Laser Scanner). Laser scanners are systems which transmit intense pulsed laser light to the ground from an airplane or a satellite, receive the scattered light, and measure the distance to the surface from the round-trip delay time of the pulse. With scanning mechanisms, GLS can obtain high-accuracy three-dimensional (3D) information from all over the world. High-accuracy 3D information is quite useful in various areas. Currently, following applications are considered. 1. Observation of tree heights to estimate the biomass quantity. 2. Making the global elevation map with high resolution. 3. Observation of ice-sheets. This paper aims at reporting the present state of our conceptual study of the GLS. A prospective performance of the GLS for earth observation missions mentioned above.

  2. Static and mobile DXA scanner in-vivo cross-calibration study

    International Nuclear Information System (INIS)

    Griffin, J.G.L.; Knapp, K.M.; Pearce, G.

    2013-01-01

    In-vitro cross-calibration of DXA scanning equipment, with a phantom device, has been recommended for assessing agreement between devices co-located within DXA scanning services. This study evaluated in-vivo and in-vitro cross-calibration of a static and a mobile DXA scanner within the same service in their individual clinical settings. 50 individuals from a volunteer group were recruited to take part in this study and had DXA measurements made on two GE Lunar Prodigy Advance (GE Lunar, Bedford, UK) scanners. Results in this study showed that the scanners agreed, with no clinically significant differences in BMD measurements made at the same site on the individual devices used in this study. The in-vivo cross-calibration of the instruments was a useful experience, which demonstrated closely calibrated systems and raised the profile of the bone densitometry service within the hospital.

  3. Circumference estimation using 3D-whole body scanners and shadow scanner

    NARCIS (Netherlands)

    Daanen, H.A.M.

    1998-01-01

    Clothing designers and manufacturers use traditional body dimensions as their basis. When 3D-whole body scanners are introduced to determine the body dimensions, a conversion has to be made, since scan determined circumference measures are slightly larger than the traditional values. This pilot

  4. A clever technique for placement of a urinary catheter over a wire

    Directory of Open Access Journals (Sweden)

    Joel E Abbott

    2015-01-01

    Conclusion: Placing urinary catheters over a wire is standard practice for urologists, however, use of this technique gives the freedom of performing wire-guided catheterization in more situations than a council-tip allows. This technique facilitates successful transurethral catheterization over wire in the setting of DUC for all catheter types and styles aiding in urologic management of patients at a cost benefit to the health care system.

  5. Interferometric Laser Scanner for Direction Determination

    Directory of Open Access Journals (Sweden)

    Gennady Kaloshin

    2016-01-01

    Full Text Available In this paper, we explore the potential capabilities of new laser scanning-based method for direction determination. The method for fully coherent beams is extended to the case when interference pattern is produced in the turbulent atmosphere by two partially coherent sources. The performed theoretical analysis identified the conditions under which stable pattern may form on extended paths of 0.5–10 km in length. We describe a method for selecting laser scanner parameters, ensuring the necessary operability range in the atmosphere for any possible turbulence characteristics. The method is based on analysis of the mean intensity of interference pattern, formed by two partially coherent sources of optical radiation. Visibility of interference pattern is estimated as a function of propagation pathlength, structure parameter of atmospheric turbulence, and spacing of radiation sources, producing the interference pattern. It is shown that, when atmospheric turbulences are moderately strong, the contrast of interference pattern of laser scanner may ensure its applicability at ranges up to 10 km.

  6. Optofluidic laser scanner based on a rotating liquid prism.

    Science.gov (United States)

    Kopp, Daniel; Lehmann, Lukas; Zappe, Hans

    2016-03-20

    We demonstrate an electrowetting-actuated optofluidic system based on a rotatable liquid prism implemented as a two-dimensional laser scanner. The system is fabricated through a novel technology using a patterned flexible polymeric foil on which a high density of electrodes is structured and which is subsequently inserted into a cylindrical housing. The resulting radial electrode array is used for electrowetting actuation of two fluids filled into the cylinder, which allows a controllable tilt and orientation of the planar liquid interface and thus represents a tunable rotating prism. Finite element simulations and subsequent experimental verification show that this highly planar and precisely positionable liquid/liquid interface may be actuated to a deflection angle of ±6.4°, with a standard deviation of ±0.18°, and rotated 360° about the vertical axis. Power consumption is limited to several microwatts, and switching times of several hundred milliseconds were determined.

  7. High speed hydraulic scanner for deep x-ray lithography

    International Nuclear Information System (INIS)

    Milne, J.C.; Johnson, E.D.

    1997-07-01

    From their research and development in hard x-ray lithography, the authors have found that the conventional leadscrew driven scanner stages do not provide adequate scan speed or travel. These considerations have led the authors to develop a scanning system based on a long stroke hydraulic drive with 635 mm of travel and closed loop feedback to position the stage to better than 100 micrometers. The control of the device is through a PC with a custom LabView interface coupled to simple x-ray beam diagnostics. This configuration allows one to set a variety of scan parameters, including target dose, scan range, scan rates, and dose rate. Results from the prototype system at beamline X-27B are described as well as progress on a production version for the X-14B beamline

  8. High speed multi-channel nuclear fuel scanner

    International Nuclear Information System (INIS)

    Miller, H.; Shepard, S.H.

    1976-01-01

    This paper describes the NNC multichannel fuel rod scanner system. This is a production line tool, designed for continuous duty in assaying commercial nuclear fuel rods. The system uses a 252 Cf source to irradiate a segment of the fuel rod as it is transported through a detector assembly located in an irradiator. The detector assembly consists of four individual plastic scintillators. As the source neutrons irradiate the fuel rods, they cause the fissile materials in the rod to fission, which results in the coincident emission of neutrons and gammas. The coincidence electronics discriminate against noncoincidence events. The signal from the coincidence detectors is directly proportional to the rate of nuclear fission or the amount of fission material

  9. Comparison and analysis of BNCT radiation dose between gold wire and JCDS measurement

    International Nuclear Information System (INIS)

    Kageji, T.; Mizobuchi, Y.; Nagahiro, S.; Nakagawa, Y.; Kumada, Hiroaki

    2006-01-01

    We compared and evaluated boron neutron capture therapy (BNCT) radiation dose between gold wire measurement and JAERI Computational Dosimetry System (JCDS). Gold wire analysis demonstrates the actual BNCT dose though it dose not reflect the real the maximum and minimum dose in tumor tissue. We can conclude that JCDS is precise and high-reliable dose planning system for BNCT. (author)

  10. Wire Rupture Optimization in Wire Electrical Discharge Machining using Taguchi Approach

    Directory of Open Access Journals (Sweden)

    Maher Ibrahem

    2017-01-01

    Full Text Available Wire electrical discharge machining (WEDM is one of the most important nontraditional machining process that is well-known for cutting difficult to machine materials. The wire electrode along with machining parameters control the WEDM process. This research work focuses on optimizing WEDM parameters using Taguchi technique to minimize wire rupture. Experiments have been done using the L18 orthogonal array. Each experiment is repeated three times to ensure accurate readings of the wire rupture. The statistical methods of signal to noise ratio (S/N ratio is applied to study effects of peak current, pulse width, charging time, wire speed, and wire tension on wire rupture. As a results, the peak current, pulse width, and wire tension have the most significant effect on wire rupture followed by charging time and wire speed. The developed analysis can be used in the metal cutting field to identify the optimum machining parameters for less wire rupture.

  11. Enhancing wire-composite bond strength of bonded retainers with wire surface treatment.

    Science.gov (United States)

    Oesterle, L J; Shellhart, W C; Henderson, S

    2001-06-01

    Bonded orthodontic retainers with wires embedded in composite resin are commonly used for orthodontic retention. The purpose of this study was to test, in vitro, various wire surface treatments to determine the optimal method of enhancing the wire-composite bond strength. Coaxial wires and stainless steel wires with different surface treatments were bonded to bovine enamel and then pulled along their long axes with an Instron universal testing machine. Wire surface treatments included placing a right-angle bend in the wire, microetching the wire, and treating the wire with adhesion promoters; combinations of treatments were also examined. The results demonstrated a 24-fold increase in the wire-composite bond strength of wire that was microetched (sandblasted), compared with that of untreated straight wire. The difference between the amount of force required to break the bond produced by microetching alone (246.1 +/- 46.0 MPa) and that required for the bonds produced by the retentive bend (87.8 +/- 16.3 MPa), the adhesion promoters (silane, 11.0 +/- 3.1 MPa; Metal Primer, 28.5 +/- 15.8 MPa), or for any combination of surface treatments, was statistically significant. Microetching a stainless steel wire produced a higher wire-composite bond strength than that obtained from a coaxial wire (113.5 +/- 27.5 MPa). The results of this study indicate that microetching or sandblasting a stainless steel wire significantly increases the strength of the wire-composite bond.

  12. A Compact Vertical Scanner for Atomic Force Microscopes

    Directory of Open Access Journals (Sweden)

    Jae Hong Park

    2010-11-01

    Full Text Available A compact vertical scanner for an atomic force microscope (AFM is developed. The vertical scanner is designed to have no interference with the optical microscope for viewing the cantilever. The theoretical stiffness and resonance of the scanner are derived and verified via finite element analysis. An optimal design process that maximizes the resonance frequency is performed. To evaluate the scanner’s performance, experiments are performed to evaluate the travel range, resonance frequency, and feedback noise level. In addition, an AFM image using the proposed vertical scanner is generated.

  13. Achievement report for fiscal 1996 on the research and development of superconductor technology to power generation. Pt. 1. Research and development of superconducting wire, generator, total system, and refrigeration system; and verification test; 1996 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 1. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    In the research and development of superconducting wires, studies are conducted to increase the current capacity of NbTi and Nb{sub 3}Sn metal wires and to improve their properties, and to increase the current capacity of oxide materials and improve their performance making full use of the features of each manufacturing method. In the development of superconducting generators, a slow excitation response type is tested for verification, and a good result is attained; and a quick excitation response type is tested for field winding static excitation, and good performance is exhibited. Using the results so far achieved, the 200,000kW class pilot machine concept design is reviewed. In the study of total systems, feasibility is studied of a quench test for the 70,000kW class machine through simulation analyses, etc. In the development of refrigeration systems, efforts are exerted to improve on the conventional type in terms of reliability and to further improve on the improved version in terms of performance and space-saving feature. One of the endeavors involves the development of a He Brayton cycle turbine driven compressor. A multilayer cylindrical rotor is verified in terms of functions, characteristics, reliability and durability, and various data are collected toward the development of a pilot machine. (NEDO)

  14. Addressing Spatial Variability of Surface-Layer Wind with Long-Range WindScanners

    DEFF Research Database (Denmark)

    Berg, Jacob; Vasiljevic, Nikola; Kelly, Mark C.

    2015-01-01

    This paper presents an analysis of mean wind measurements from a coordinated system of long-range WindScanners. From individual scan patterns the mean wind field was reconstructed over a large area, and hence it highlights the spatial variability. From comparison with sonic anemometers, the quality...

  15. Prediction of multi performance characteristics of wire EDM process using grey ANFIS

    Science.gov (United States)

    Kumanan, Somasundaram; Nair, Anish

    2017-09-01

    Super alloys are used to fabricate components in ultra-supercritical power plants. These hard to machine materials are processed using non-traditional machining methods like Wire cut electrical discharge machining and needs attention. This paper details about multi performance optimization of wire EDM process using Grey ANFIS. Experiments are designed to establish the performance characteristics of wire EDM such as surface roughness, material removal rate, wire wear rate and geometric tolerances. The control parameters are pulse on time, pulse off time, current, voltage, flushing pressure, wire tension, table feed and wire speed. Grey relational analysis is employed to optimise the multi objectives. Analysis of variance of the grey grades is used to identify the critical parameters. A regression model is developed and used to generate datasets for the training of proposed adaptive neuro fuzzy inference system. The developed prediction model is tested for its prediction ability.

  16. Developments in the Generation and Interpretation of Wire Codes (invited paper)

    International Nuclear Information System (INIS)

    Ebi, K.L.

    1999-01-01

    Three new developments in the generation and interpretation of wire codes are discussed. First, a method was developed to computer generate wire codes using data gathered from a utility database of the local distribution system and from tax assessor records. This method was used to wire code more than 250,000 residences in the greater Denver metropolitan area. There was an approximate 75% agreement with field wire coding. Other research in Denver suggests that wire codes predict some characteristics of a residence and its neighbourhood, including age, assessed value, street layout and traffic density. A third new development is the case-specular method to study the association between wire codes and childhood cancers. Recent results from applying the method to the Savitz et al and London et al studies suggest that the associations between childhood cancer and VHCC residences were strongest for residences with a backyard rather than street service drop, and for VHCC residences with LCC speculars. (author)

  17. AC loss properties of MgB{sub 2} multifilament wires

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Kazuhide; Funaki, Kazuo; Sueyoshi, Takahiro; Sasashige, Yushi; Kajikawa, Kazuhiro; Iwakuma, Masataka [Kyushu University Graduate School of Information Science and Electrical Engineering, 744 Moto-oka, Nishi-ku, Fukuoka 819-0395 (Japan); Okada, Michiya [HRL Hitachi, Ltd, 7-1-1 Oomika, Hitachi 319-1292 (Japan); Kumakura, Hiroaki [National Institute for Materials Science, 1-2-1 Sengen, Tsukuba 305-0047 (Japan); Hayashi, Hidemi [Kyushu Electric Power Co., Incorporated, 2-1-47 Shiobaru, Minami-ku, Fukuoka 815-8520 (Japan)], E-mail: kazuhide.tanaka.je@hitachi.com

    2008-09-15

    We designed and fabricated two types of composite wires with 6 MgB{sub 2} filaments. One is a Cu-sheathed Nb-barrier wire and the other is a CuNi-sheathed Ta-barrier wire. The transverse-field losses of the trial wires were measured with a standardized pickup coil system in liquid helium. We evaluated the observed AC losses using two structural models, a multifilament conductor model and a hollow-cylindrical one. For the CuNi-sheathed Ta-barrier wire, the AC loss property can be explained by the usual model of multifilament conductors. Further reductions in AC loss can be expected by making the filaments thinner. For the Cu-sheathed Nb-barrier wire, theoretical considerations suggest the multifilament structure behaves as a hollow-cylindrical superconductor in the AC loss property. Thus, we need to pay particular attention to designing the barrier material for reduction in the AC loss.

  18. Process water reduction in a wire milling operation. 1989 summer intern report

    Energy Technology Data Exchange (ETDEWEB)

    Alberg, J.

    1989-12-31

    Johnson Filtration Systems is a company located in New Brighton, Minnesota which employs 256 people. The focus of the project was to reduce the water usage of the wire milling operation. Water in the milling process is used to clean the wire and cool the mill components. Total annual water usage for this operation is six million gallons. The milling process changes the cross sectional shape of the wire by using flattening hammers and rollers. A synthetic coolant is used to enhance this process and remove heat. The coolant is removed from the wire as it is pulled through a squeegee, washed it with water and dried with an air knife.

  19. MFP scanner diagnostics using a self-printed target to measure the modulation transfer function

    Science.gov (United States)

    Wang, Weibao; Bauer, Peter; Wagner, Jerry; Allebach, Jan P.

    2014-01-01

    In the current market, reduction of warranty costs is an important avenue for improving profitability by manufacturers of printer products. Our goal is to develop an autonomous capability for diagnosis of printer and scanner caused defects with mid-range laser multifunction printers (MFPs), so as to reduce warranty costs. If the scanner unit of the MFP is not performing according to specification, this issue needs to be diagnosed. If there is a print quality issue, this can be diagnosed by printing a special test page that is resident in the firmware of the MFP unit, and then scanning it. However, the reliability of this process will be compromised if the scanner unit is defective. Thus, for both scanner and printer image quality issues, it is important to be able to properly evaluate the scanner performance. In this paper, we consider evaluation of the scanner performance by measuring its modulation transfer function (MTF). The MTF is a fundamental tool for assessing the performance of imaging systems. Several ways have been proposed to measure the MTF, all of which require a special target, for example a slanted-edge target. It is unacceptably expensive to ship every MFP with such a standard target, and to expect that the customer can keep track of it. To reduce this cost, in this paper, we develop new approach to this task. It is based on a self-printed slanted-edge target. Then, we propose algorithms to improve the results using a self-printed slanted-edge target. Finally, we present experimental results for MTF measurement using self-printed targets and compare them to the results obtained with standard targets.

  20. Novel Wiring Technologies for Aerospace Applications

    Science.gov (United States)

    Gibson, Tracy L.; Parrish, Lewis M.

    2014-01-01

    Because wire failure in aerospace vehicles could be catastrophic, smart wiring capabilities have been critical for NASA. Through the years, researchers at Kennedy Space Center (KSC) have developed technologies, expertise, and research facilities to meet this need. In addition to aerospace applications, NASA has applied its knowledge of smart wiring, including self-healing materials, to serve the aviation industry. This webinar will discuss the development efforts of several wiring technologies at KSC and provide insight into both current and future research objectives.

  1. Clinical bending of nickel titanium wires

    OpenAIRE

    Stephen Chain; Priyank Seth; Namrata Rastogi; Kenneth Tan; Mayank Gupta; Richa Singh

    2015-01-01

    Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our invento...

  2. Towards Unconventional Applications of Wire Bonding

    OpenAIRE

    Schröder, Stephan

    2018-01-01

    This thesis presents novel heterogeneous integration approaches of wire materials to fabricated and package MEMS devices by exploring unconventional applications of wire bonding technology. Wire bonding, traditionally endemic in the realm of device packaging to establish electrical die-to-package interconnections, is an attractive back-end technology, offering promising features, such as high throughput, flexibility and placement accuracy. Exploiting the advantages of state-of-the-art wire bo...

  3. Different mechanical properties in Seldinger guide wires

    Directory of Open Access Journals (Sweden)

    Wolfram Schummer

    2015-01-01

    Full Text Available Background and Aims: Most central venous catheters are placed using Seldinger guide wires. EN ISO 11070 is the guideline for testing guide wire flexing performance and tensile strength, and we can safely assume that guide wires in use meet these requirements. Unfortunately, EN ISO 11070 guidelines do not reflect the clinical requirements and we continue to see mechanical failures and their associated complications. Material and Methods: This in vitro study was performed in an accredited laboratory. With regard to flexing, we: (1 Established the minimum flexing performance needed to meet clinical requirements, (2 developed flexing performance tests which mimic clinical requirement, and (3 evaluated the mechanical properties of various guide wires relative to these requirements. With regard to tensile strength, we used the testing method prescribed in ISO 11070, but did not end the test at 5 Newton (N. We continued until the guide wire was damaged, or we reached maximum tractive force. We then did a wire-to-wire comparison. We examined two basic wire constructions, monofil and core and coil. Results: Tensile strength: All wires tested, except one, met EN ISO 11070 requirements for 5 N tensile strength. The mean of the wire types tested ranged from 15.06 N to 257.76 N. Flexing performance: None of the wires kinked. The monofil had no evidence of bending. Two core/coil wires displayed minor bending (angle 1.5°. All other wires displayed bending angles between 22.5° and 43.0°. Conclusion: We recommend that: (1 Clinicians use guide wires with high-end mechanical properties, (2 EN ISO 11070 incorporate our flexing test into their testing method, raise the flexing requirement to kink-proof, (3 and raise the tensile strength requirement to a minimum of 30 N, and (3 all manufacturers and suppliers be required to display mechanical properties of all guide wire, and guide wire kits sold.

  4. Vocational Preparation Curriculum: Electrical Wiring.

    Science.gov (United States)

    Usoro, Hogan

    This document is a curriculum guide for instructors teaching vocational preparation for electrical wiring to special needs students. The purpose of the curriculum guide is to provide minimum skills for disadvantaged and handicapped students entering the mainstream; to supplement vocational skills of those students already in a regular training…

  5. Fine-Filament MgB2 Superconductor Wire

    Science.gov (United States)

    Cantu, Sherrie

    2015-01-01

    Hyper Tech Research, Inc., has developed fine-filament magnesium diboride (MgB2) superconductor wire for motors and generators used in turboelectric aircraft propulsion systems. In Phase I of the project, Hyper Tech demonstrated that MgB2 multifilament wires (superconductor and engineering current density and AC losses. Hyper Tech also fabricated MgB2 rotor coil packs for a superconducting generator. The ultimate goal is to enable low-cost, round, lightweight, low-AC-loss superconductors for motor and generator stator coils operating at 25 K in next-generation turboelectric aircraft propulsion systems.

  6. Transport in quantum wires

    Indian Academy of Sciences (India)

    With a brief introduction to one-dimensional channels and conductance quantization in mesoscopic systems, we discuss some recent experimental puzzles in these systems, which include reduction of quantized conductances and an interesting odd–even effect in the presence of an in-plane magnetic field. We then discuss ...

  7. Performance Evaluation of a PEM Scanner Using the NEMA NU 4—2008 Small Animal PET Standards

    Science.gov (United States)

    Luo, Weidong; Anashkin, Edward; Matthews, Christopher G.

    2010-02-01

    The recently published NEMA NU 4-2008 Standards has been specially designed for evaluating the performance of small animal PET scanners used in preclinical applications. In this paper, we report on the NU 4 performance of a clinical positron emission mammography (PEM) system. Since there are no PEM specific performance test protocols available, and the NU 2 protocol (intended for whole-body PET scanners) cannot be applied without modification due to the compact design of the PEM scanner, we decided to evaluate the NU 4 Standards as an alternative. We obtained the following results: Trans-axial spatial resolution 1.8 mm FWHM for high resolution reconstruction mode and 2.4 mm FWHM for standard resolution reconstruction mode with no significant variation within the field of view. The total system sensitivity was 0.16 cps/Bq. In image quality testing, the uniformity was found to be 3.9% STD at the standard resolution mode and 5.6% at the high resolution mode when measured with a 34 mm paddle separation. The NEMA NU 4-2008 Standards were found to be a practicable tool to evaluate the performance of the PEM scanner after some modifications to address the specifics of its detector configuration. Furthermore, the PEM scanner's in-plane spatial resolution was comparable to other small animal PET scanners with good image quality.

  8. Multi-anode wire straw tube tracker

    International Nuclear Information System (INIS)

    Oh, S.H.; Ebenstein, W.L.; Wang, C.W.

    2011-01-01

    We report on a test of a straw tube detector design having several anode (sense) wires inside a straw tube. The anode wires form a circle inside the tube and are read out independently. This design could solve several shortcomings of the traditional single wire straw tube design such as double hit capability and stereo configuration.

  9. Home and School Technology: Wired versus Wireless.

    Science.gov (United States)

    Van Horn, Royal

    2001-01-01

    Presents results of informal research on smart homes and appliances, structured home wiring, whole-house audio/video distribution, hybrid cable, and wireless networks. Computer network wiring is tricky to install unless all-in-one jacketed cable is used. Wireless phones help installers avoid pre-wiring problems in homes and schools. (MLH)

  10. On the preparation of superconducting wires

    International Nuclear Information System (INIS)

    Topare, R.J.; Chinchure, A.D.; Shah, S.S.; Hadole, G.B.

    1993-01-01

    The different methods of preparation of superconducting wires have been discussed. The powder-in-tube technique is followed for the preparation of YBCO and BISCCO superconducting wires. The results are discussed. The present status of the industries in preparing the superconducting wires having the maximum J c values is discussed. (author). 30 refs., 6 figs., 2 tabs

  11. 75 FR 4584 - Wire Decking From China

    Science.gov (United States)

    2010-01-28

    ... COMMISSION Wire Decking From China AGENCY: United States International Trade Commission. ACTION: Scheduling... retarded, by reason of subsidized and less-than-fair-value imports from China of wire decking, provided for..., producers, or exporters in China of wire decking, and that such ] products are being sold in the United...

  12. Compact beamforming in medical ultrasound scanners

    DEFF Research Database (Denmark)

    Tomov, Borislav Gueorguiev

    2003-01-01

    to fit a large number of channels on a single integrated circuit. The use of oversampled analog-to-digital (A/D) converters with the corresponding beamforming was identified as a particularly promising approach, since it provides both inexpensive and compact A/D conversion and allows for much more...... channels, and even more channels are necessary for 3-dimensional (3D) diagnostic imaging. On the other hand, there is a demand for inexpensive portable devices for use outside hospitals, in field conditions, where power consumption and compactness are important factors. The thesis starts...... quality is comparable to that of the very good scanners currently on the market. The performance results have been achieved with the use of a simple oversampled converter of second order. The use of a higher order oversampled converter will allow higher pulse frequency to be used while the high dynamic...

  13. Development of scintillation materials for PET scanners

    CERN Document Server

    Korzhik, Mikhail; Annenkov, Alexander N; Borissevitch, Andrei; Dossovitski, Alexei; Missevitch, Oleg; Lecoq, Paul

    2007-01-01

    The growing demand on PET methodology for a variety of applications ranging from clinical use to fundamental studies triggers research and development of PET scanners providing better spatial resolution and sensitivity. These efforts are primarily focused on the development of advanced PET detector solutions and on the developments of new scintillation materials as well. However Lu containing scintillation materials introduced in the last century such as LSO, LYSO, LuAP, LuYAP crystals still remain the best PET species in spite of the recent developments of bright, fast but relatively low density lanthanum bromide scintillators. At the same time Lu based materials have several drawbacks which are high temperature of crystallization and relatively high cost compared to alkali-halide scintillation materials. Here we describe recent results in the development of new scintillation materials for PET application.

  14. Adolescent patient with bilateral crossbite treated with surgically assisted rapid maxillary expansion: a case report evaluated by the 3d laser scanner, and using FESA method.

    Science.gov (United States)

    Ivanov, Ch I; Velemínská, J; Dostálová, T; Foltán, R

    2011-01-01

    Our purpose in this case report is to present an orthodontic treatment obtained and the results achieved in 17-year-old white female patient with Angle Class II malocclusion and bilateral posterior crossbite. Patient was treated with bonded acrylic Hyrax appliance and surgically assisted rapid maxillary expansion (SARME). The multiloop system 0.16 TMA (ß titanium) arch wire was used in the alignment phase and on purpose to prohibit bite opening and optimize threedimensional movement control. After treatment bonded lingual retainers were placed in between maxillary central incisors and in mandible canine-to-canine. A functional removable Klammt appliance was used for retention. The 3D Laser Scanner Roland LPX-250 was used in order to obtain digital dental casts. Evaluation of the treatment results was measured on these models and using finite element scaling analysis (FESA). An Angle Class I relationship was obtained after 2½ years of treatment, function and facial aesthetics were improved. The shape of the palate changed significant in the width direction, not significantly in length and high direction. The greatest expansion of palate was found in the region between the palatal cusps of the first molars 26.6%, followed by first 21.9% and second premolars 16.5%. SARME in adult patients with bilateral cross bite and maxillary deficiency lead to satisfactory results. The 3D laser scanned models and their measurements, using advanced software's are successfully used for precise studies.

  15. Report on results for fiscal 1997 on development of superconducting electric power application technology. Pt. 1. R and D of superconducting wire, R and D of superconducting generator, studies on total system, R and D of refrigeration system, and verification test; 1997 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 1. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    This report explains the outline as Part 1. In fiscal 1997, the 10th year of the project, a multi cylindrical rotary model for which an in-situ verification test was finished was brought back to the plant and dismantled for examination, while the in-situ verification test of a slow-response type model machine rotor was conducted in combination with a refrigeration system. In addition, in the research of AC wire materials and oxide based materials, studies were made with a purpose of high characterization and long wire materialization. In the metallic materials, a 10kANbTi conductor was developed while, in oxide-based materials, research was done on performance improvement and wire materialization based on various synthesizing methods. The manufacturing, factory test and in-situ text were conducted for a 70,000kW model machine with the purpose of R and D of a 200,000kW class pilot machine. Examination was made on the test method of the 70,000kW class model machine, operation technology of a superconducting generation system, and the effect of introducing the superconducting generator into a power system. In the conventional refrigeration system, a single unit test was carried out for the liquefaction, liquid storing capacity, etc., of the system. The 70,000kW class model machine was put through a test for confirming the general operation including the refrigeration system. (NEDO)

  16. Spectra of clinical CT scanners using a portable Compton spectrometer

    NARCIS (Netherlands)

    Duisterwinkel, Erik; van Abbema, J. K.; van Goethem, M. J.; Kawachimaru, R.; Paganini, Lucia; van der Graaf, E. R.; Brandenburg, Sijtze

    PURPOSE: Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate,

  17. Vision Assisted Laser Scanner Navigation for Autonomous Robots

    DEFF Research Database (Denmark)

    Andersen, Jens Christian; Andersen, Nils Axel; Ravn, Ole

    2008-01-01

    This paper describes a navigation method based on road detection using both a laser scanner and a vision sensor. The method is to classify the surface in front of the robot into traversable segments (road) and obstacles using the laser scanner, this classifies the area just in front of the robot (2...

  18. Spatiotemporal treadmill gait measurements using a laser range scanner: feasibility study of the healthy young adults.

    Science.gov (United States)

    Tanabe, S; Ii, T; Koyama, S; Saitoh, E; Itoh, N; Ohtsuka, K; Katoh, Y; Shimizu, A; Tomita, Y

    2017-04-01

    Spatio-temporal parameters are typically used for gait analysis. Although these parameters are measured by sophisticated systems such as 3D motion capture system or optoelectronic bars, these systems cannot be deployed easily because of their high costs, large space requirements and elaborate set-up. The purpose of this study is to develope a system for measuring spatiotemporal gait parameters using a laser range scanner during treadmill gait. To calculate accurate spatiotemporal parameters, the differences between the laser range scanner measured values and the reference values obtained from a 3D motion capture system were investigated in thirty subjects. From measurements in time and position at foot contact/off, adjustments to compensate for the differences in time and position were derived. Then, to determine the validity of the proposed system, values from the proposed system and the reference system were compared in four additional subjects. The results indicate that the data from the laser range scanner demonstrate certain differences in time and position compared with reference values. However, when compensation values were introduced, each spatiotemporal parameter correlated well with the reference values. This newer system is smaller, is easier to deploy and requires less training than the 3D motion capture system.

  19. Torque resistance of different stainless steel wires commonly used for fixed retainers in orthodontics.

    Science.gov (United States)

    Arnold, Dario T; Dalstra, Michel; Verna, Carlalberta

    2016-06-01

    Movements of teeth splinted by fixed retention wires after orthodontic treatment have been observed. The aetiological factors for these movements are unknown. The aim of this in vitro study was to compare the resistance to torque of different stainless steel wires commonly used for fixed retainers in orthodontics. Torquing moments acting on a retainer wire were measured in a mechanical force testing system by applying buccal crown torque to an upper lateral incisor in both a 3-teeth and in a 2-teeth setup. Seven stainless steel wires with different shape, type (plain, braided, coaxial, or chain) and dimensions were selected for this study. For a torquing angle of 16.2° in the 3-teeth setup torsion moments can vary between 390 cNmm and 3299 cNmm depending on the retainer wire. For the 2-teeth setup the torsion moments are much smaller. Exposure to the flame of a butane-gas torch for 10 seconds to anneal the wire reduces the stiffness of the retainer wire. Clinicians must select wires for fixed retainers very carefully since the difference in resistance to torque is large. A high level of torque control can be achieved with a plain 0.016 × 0.016-inch or a braided 0.016 × 0.022-inch stainless steel wire. A tooth attached by a retainer wire to only one neighbouring tooth is less resistant to torque than a tooth connected to two neighbouring teeth. Annealing a retainer wire with a flame reduces the stiffness of the wire markedly and can lead to a non-uniform and non-reproducible effect.

  20. 46 CFR 111.105-17 - Wiring methods for hazardous locations.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wiring methods for hazardous locations. 111.105-17 Section 111.105-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-17 Wiring methods for...