  1. A LITERATURE REVIEW OF WIPE SAMPLING METHODS FOR CHEMICAL WARFARE AGENTS AND TOXIC INDUSTRIAL CHEMICALS

    Science.gov (United States)

    Wipe sampling is an important technique for the estimation of contaminant deposition in buildings, homes, or outdoor surfaces as a source of possible human exposure. Numerousmethods of wipe sampling exist, and each method has its own specification for the type of wipe, we...

  2. New approaches to wipe sampling methods for antineoplastic and other hazardous drugs in healthcare settings.

    Science.gov (United States)

    Connor, Thomas H; Smith, Jerome P

    2016-09-01

    At the present time, the method of choice to determine surface contamination of the workplace with antineoplastic and other hazardous drugs is surface wipe sampling and subsequent sample analysis with a variety of analytical techniques. The purpose of this article is to review current methodology for determining the level of surface contamination with hazardous drugs in healthcare settings and to discuss recent advances in this area. In addition it will provide some guidance for conducting surface wipe sampling and sample analysis for these drugs in healthcare settings. Published studies on the use of wipe sampling to measure hazardous drugs on surfaces in healthcare settings drugs were reviewed. These studies include the use of well-documented chromatographic techniques for sample analysis in addition to newly evolving technology that provides rapid analysis of specific antineoplastic. Methodology for the analysis of surface wipe samples for hazardous drugs are reviewed, including the purposes, technical factors, sampling strategy, materials required, and limitations. The use of lateral flow immunoassay (LFIA) and fluorescence covalent microbead immunosorbent assay (FCMIA) for surface wipe sample evaluation is also discussed. Current recommendations are that all healthc a re settings where antineoplastic and other hazardous drugs are handled include surface wipe sampling as part of a comprehensive hazardous drug-safe handling program. Surface wipe sampling may be used as a method to characterize potential occupational dermal exposure risk and to evaluate the effectiveness of implemented controls and the overall safety program. New technology, although currently limited in scope, may make wipe sampling for hazardous drugs more routine, less costly, and provide a shorter response time than classical analytical techniques now in use.

  3. Wipe sampling - review of the literature

    International Nuclear Information System (INIS)

    Souza, Daiane Cristini Barbosa de; Vicente, Roberto

    2011-01-01

    Methods for characterization of solid, non-compactable radioactive wastes contaminated in the surface are developed aiming at estimating the waste radioisotopic inventory for regulatory compliance and operational purposes. The wastes of interest here are mainly composed of plastic, metallic, or other materials parts originated in the decommissioning and maintenance operations of nuclear facilities. One way of measuring surface contamination is the indirect method of wiping the contaminated surface and counting the wipe, a common method of detecting non-fixed contamination in the radiation protection routine. The wipe sampling is an important tool in controlling the quality of the workplace in nuclear and radioactive facilities. Although radioprotection regulations establish quantitative limits, the practice in the radiation protection routine is to use wipe sampling as a qualitative measurement. To product useful quantitative results for inventorying radioactive wastes, a quantitative approach must be adopted. A previous paper presented by the authors in the last INAC Conference discussed alternative wipe materials and protocols. The method of wipe sampling underwent small changes since it started to be used but still is the object of study, as it is attested by many recent papers and patents on the subject. This article consists of a literature review. Results of a survey in the literature about wipe sampling techniques that can be applied to waste characterization are presented. (author)

  4. Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives.

    Science.gov (United States)

    Verkouteren, Jennifer R; Lawrence, Jeffrey A; Staymates, Matthew E; Sisco, Edward

    2017-04-10

    One of the limiting steps to detecting traces of explosives at screening venues is effective collection of the sample. Wipe-sampling is the most common procedure for collecting traces of explosives, and standardized measurements of collection efficiency are needed to evaluate and optimize sampling protocols. The approach described here is designed to provide this measurement infrastructure, and controls most of the factors known to be relevant to wipe-sampling. Three critical factors (the applied force, travel distance, and travel speed) are controlled using an automated device. Test surfaces are chosen based on similarity to the screening environment, and the wipes can be made from any material considered for use in wipe-sampling. Particle samples of the explosive 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) are applied in a fixed location on the surface using a dry-transfer technique. The particle samples, recently developed to simulate residues made after handling explosives, are produced by inkjet printing of RDX solutions onto polytetrafluoroethylene (PTFE) substrates. Collection efficiency is measured by extracting collected explosive from the wipe, and then related to critical sampling factors and the selection of wipe material and test surface. These measurements are meant to guide the development of sampling protocols at screening venues, where speed and throughput are primary considerations.

  5. Laboratory Validation and Field Assessment of Petroleum Laboratory Technicians' Dermal Exposure to Crude Oil Using a Wipe Sampling Method.

    Science.gov (United States)

    Galea, Karen S; Mueller, Will; Arfaj, Ayman M; Llamas, Jose L; Buick, Jennifer; Todd, David; McGonagle, Carolyn

    2018-05-21

    Crude oil may cause adverse dermal effects therefore dermal exposure is an exposure route of concern. Galea et al. (2014b) reported on a study comparing recovery (wipe) and interception (cotton glove) dermal sampling methods. The authors concluded that both methods were suitable for assessing dermal exposure to oil-based drilling fluids and crude oil but that glove samplers may overestimate the amount of fluid transferred to the skin. We describe a study which aimed to further evaluate the wipe sampling method to assess dermal exposure to crude oil, with this assessment including extended sample storage periods and sampling efficiency tests being undertaken at environmental conditions to mimic those typical of outdoor conditions in Saudi Arabia. The wipe sampling method was then used to assess the laboratory technicians' actual exposure to crude oil during typical petroleum laboratory tasks. Overall, acceptable storage efficiencies up to 54 days were reported with results suggesting storage stability over time. Sampling efficiencies were also reported to be satisfactory at both ambient and elevated temperature and relative humidity environmental conditions for surrogate skin spiked with known masses of crude oil and left up to 4 h prior to wiping, though there was an indication of reduced sampling efficiency over time. Nineteen petroleum laboratory technicians provided a total of 35 pre- and 35 post-activity paired hand wipe samples. Ninety-three percent of the pre-exposure paired hand wipes were less than the analytical limit of detection (LOD), whereas 46% of the post-activity paired hand wipes were less than the LOD. The geometric mean paired post-activity wipe sample measurement was 3.09 µg cm-2 (range 1.76-35.4 µg cm-2). It was considered that dermal exposure most frequently occurred through direct contact with the crude oil (emission) or via deposition. The findings of this study suggest that the wipe sampling method is satisfactory in quantifying

  6. False negative rate and other performance measures of a sponge-wipe surface sampling method for low contaminant concentrations.

    Energy Technology Data Exchange (ETDEWEB)

    Einfeld, Wayne; Krauter, Paula A.; Boucher, Raymond M.; Tezak, Mathew; Amidan, Brett G. (Pacific Northwest National Laboratory, Richland, WA); Piepel, Greg F. (Pacific Northwest National Laboratory, Richland, WA)

    2011-05-01

    Recovery of spores from environmental surfaces is known to vary due to sampling methodology, techniques, spore size and characteristics, surface materials, and environmental conditions. A series of tests were performed to evaluate a new, validated sponge-wipe method. Specific factors evaluated were the effects of contaminant concentrations and surface materials on recovery efficiency (RE), false negative rate (FNR), limit of detection (LOD) - and the uncertainties of these quantities. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show a roughly linear dependence of surface roughness on RE, where the smoothest surfaces have the highest mean RE values. REs were not influenced by the low spore concentrations tested (3 x 10{sup -3} to 1.86 CFU/cm{sup 2}). The FNR data were consistent with RE data, showing a trend of smoother surfaces resulting in higher REs and lower FNRs. Stainless steel generally had the lowest mean FNR (0.123) and plastic had the highest mean FNR (0.479). The LOD{sub 90} varied with surface material, from 0.015 CFU/cm{sup 2} on stainless steel up to 0.039 on plastic. Selecting sampling locations on the basis of surface roughness and using roughness to interpret spore recovery data can improve sampling. Further, FNR values, calculated as a function of concentration and surface material, can be used pre-sampling to calculate the numbers of samples for statistical sampling plans with desired performance, and post-sampling to calculate the confidence in characterization and clearance decisions.

  7. Sampling for Beryllium Surface Contamination using Wet, Dry and Alcohol Wipe Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, Kent [Central Missouri State Univ., Warrensburg, MO (United States)

    2004-12-01

    This research project was conducted at the National Nuclear Security Administration's Kansas City Plant, operated by Honeywell Federal Manufacturing and Technologies, in conjunction with the Safety Sciences Department of Central Missouri State University, to compare relative removal efficiencies of three wipe sampling techniques currently used at Department of Energy facilities. Efficiencies of removal of beryllium contamination from typical painted surfaces were tested by wipe sampling with dry Whatman 42 filter paper, with water-moistened (Ghost Wipe) materials, and by methanol-moistened wipes. Test plates were prepared using 100 mm X 15 mm Pyrex Petri dishes with interior surfaces spray painted with a bond coat primer. To achieve uniform deposition over the test plate surface, 10 ml aliquots of solution containing 1 beryllium and 0.1 ml of metal working fluid were transferred to the test plates and subsequently evaporated. Metal working fluid was added to simulate the slight oiliness common on surfaces in metal working shops where fugitive oil mist accumulates over time. Sixteen test plates for each wipe method (dry, water, and methanol) were processed and sampled using a modification of wiping patterns recommended by OSHA Method 125G. Laboratory and statistical analysis showed that methanol-moistened wipe sampling removed significantly more (about twice as much) beryllium/oil-film surface contamination as water-moistened wipes (p< 0.001), which removed significantly more (about twice as much) residue as dry wipes (p <0.001). Evidence for beryllium sensitization via skin exposure argues in favor of wipe sampling with wetting agents that provide enhanced residue removal efficiency.

  8. Wipe sampling for characterization of noncompactable radioactive waste

    International Nuclear Information System (INIS)

    Barbieri, Aline E.O.; Ferreira, Robson J.; Vicente, Roberto

    2009-01-01

    Wipe sampling is a method of monitoring radioactive surface contamination on working area and on radioactive, non-compactable wastes, constituted of large pieces of replaced parts of equipment in nuclear and radioactive installations. In this method, sampling is executed by rubbing a disc of filter paper on the contaminated surface in such a way as to collect entirely or partially the deposited material. The target radioisotopes are subsequently measured directly on the wipe or extracted by appropriate radio analytical methods and then qualitatively and quantitatively determined. The collection factor, or the efficiency with which the material is removed from the surface and deposited on the smear, is the main source of error in quantitative measurements. The determination of the collection efficiency is the object of this communication. (author)

  9. Lessons learned from surface wipe sampling for lead in three workplaces.

    Science.gov (United States)

    Beaucham, Catherine; Ceballos, Diana; King, Bradley

    2017-08-01

    Surface wipe sampling in the occupational environment is a technique widely used by industrial hygienists. Although several organizations have promulgated standards for sampling lead and other metals, uncertainty still exists when trying to determine an appropriate wipe sampling strategy and how to interpret sampling results. Investigators from the National Institute for Occupational Safety and Health (NIOSH) Health Hazard Evaluation Program have used surface wipe sampling as part of their exposure assessment sampling strategies in a wide range of workplaces. This article discusses wipe sampling for measuring lead on surfaces in three facilities: (1) a battery recycling facility; (2) a firing range and gun store; and (3) an electronic scrap recycling facility. We summarize our findings from the facilities and what we learned by integrating wipe sampling into our sampling plan. Wiping sampling demonstrated lead in non-production surfaces in all three workplaces and that the potential that employees were taking lead home to their families existed. We also found that the presence of metals such as tin can interfere with the colorimetric results. We also discuss the advantages and disadvantages of colorimetric analysis of surface wipe samples and the challenges we faced when interpreting wipe sampling results.

  10. Do new wipe materials outperform traditional lead dust cleaning methods?

    Science.gov (United States)

    Lewis, Roger D; Ong, Kee Hean; Emo, Brett; Kennedy, Jason; Brown, Christopher A; Condoor, Sridhar; Thummalakunta, Laxmi

    2012-01-01

    Government guidelines have traditionally recommended the use of wet mopping, sponging, or vacuuming for removal of lead-contaminated dust from hard surfaces in homes. The emergence of new technologies, such as the electrostatic dry cloth and wet disposable clothes used on mopheads, for removal of dust provides an opportunity to evaluate their ability to remove lead compared with more established methods. The purpose of this study was to determine if relative differences exist between two new and two older methods for removal of lead-contaminated dust (LCD) from three wood surfaces that were characterized by different roughness or texture. Standard leaded dust, coefficient of friction was performed for each wipe material. Analysis of variance was used to evaluate the surface and cleaning methods. There were significant interactions between cleaning method and surface types, p = 0.007. Cleaning method was found be a significant factor in removal of lead, p coefficient of friction, significantly different among the three wipes, is likely to influence the cleaning action. Cleaning method appears to be more important than texture in LCD removal from hard surfaces. There are some small but important factors in cleaning LCD from hard surfaces, including the limits of a Swiffer mop to conform to curved surfaces and the efficiency of the wetted shop towel and vacuuming for cleaning all surface textures. The mean percentage reduction in lead dust achieved by the traditional methods (vacuuming and wet wiping) was greater and more consistent compared to the new methods (electrostatic dry cloth and wet Swiffer mop). Vacuuming and wet wiping achieved lead reductions of 92% ± 4% and 91%, ± 4%, respectively, while the electrostatic dry cloth and wet Swiffer mops achieved lead reductions of only 89 ± 8% and  81 ± 17%, respectively.

  11. Wipe sampling for nicotine as a marker of thirdhand tobacco smoke contamination on surfaces in homes, cars, and hotels.

    Science.gov (United States)

    Quintana, Penelope J E; Matt, Georg E; Chatfield, Dale; Zakarian, Joy M; Fortmann, Addie L; Hoh, Eunha

    2013-09-01

    Secondhand smoke contains a mixture of pollutants that can persist in air, dust, and on surfaces for months or longer. This persistent residue is known as thirdhand smoke (THS). Here, we detail a simple method of wipe sampling for nicotine as a marker of accumulated THS on surfaces. We analyzed findings from 5 real-world studies to investigate the performance of wipe sampling for nicotine on surfaces in homes, cars, and hotels in relation to smoking behavior and smoking restrictions. The intraclass correlation coefficient for side-by-side samples was 0.91 (95% CI: 0.87-0.94). Wipe sampling for nicotine reliably distinguished between private homes, private cars, rental cars, and hotels with and without smoking bans and was significantly positively correlated with other measures of tobacco smoke contamination such as air and dust nicotine. The sensitivity and specificity of possible threshold values (0.1, 1, and 10 μg/m(2)) were evaluated for distinguishing between nonsmoking and smoking environments. Sensitivity was highest at a threshold of 0.1 μg/m(2), with 74%-100% of smoker environments showing nicotine levels above threshold. Specificity was highest at a threshold of 10 μg/m(2), with 81%-100% of nonsmoker environments showing nicotine levels below threshold. The optimal threshold will depend on the desired balance of sensitivity and specificity and on the types of smoking and nonsmoking environments. Surface wipe sampling for nicotine is a reliable, valid, and relatively simple collection method to quantify THS contamination on surfaces across a wide range of field settings and to distinguish between nonsmoking and smoking environments.

  12. Evaluation and Prediction present of radionuclide for surface wipe sample in Emergency Related with Fukushima Nuclear Accident

    International Nuclear Information System (INIS)

    Zalina Laili; Muhamat Omar; Woo, Y.M.

    2011-01-01

    Surface wipe samples of aircraft and container from Japan that were exposed to radioactive dust fallout due to Fukushima nuclear accident has been analysed using gamma spectrometry systems. The samples were analysed to determine their contamination levels. The surface of aircraft and container might be exposed to short and long lived fission and activation products. Thus, good evaluations, as well as a reliable and reasonable judgment were needed in order to determine the presence of fission and activation products. A work procedure has been developed to evaluate and predict the presence of fission and activation products in surface wipe samples. Good references, skilled and experienced level in analysis, a well calibrated and validated detector system were the important factors in determining the presence of fission and activation products in surface wipe samples. (author)

  13. Air, hand wipe, and surface wipe sampling for Bisphenol A (BPA) among workers in industries that manufacture and use BPA in the United States.

    Science.gov (United States)

    Hines, Cynthia J; Jackson, Matthew V; Christianson, Annette L; Clark, John C; Arnold, James E; Pretty, Jack R; Deddens, James A

    2017-11-01

    For decades, bisphenol A (BPA) has been used in making polycarbonate, epoxy, and phenolic resins and certain investment casting waxes, yet published exposure data are lacking for U.S. manufacturing workers. In 2013-2014, BPA air and hand exposures were quantified for 78 workers at six U.S. companies making BPA or BPA-based products. Exposure measures included an inhalable-fraction personal air sample on each of two consecutive work days (n = 146), pre- and end-shift hand wipe samples on the second day (n = 74 each), and surface wipe samples (n = 88). Potential determinants of BPA air and end-shift hand exposures (after natural log transformation) were assessed in univariate and multiple regression mixed models. The geometric mean (GM) BPA air concentration was 4.0 µg/m 3 (maximum 920 µg/m 3 ). The end-shift GM BPA hand level (26 µg/sample) was 10-times higher than the pre-shift level (2.6 µg/sample). BPA air and hand exposures differed significantly by industry and job. BPA air concentrations and end-shift hand levels were highest in the BPA-filled wax manufacturing/reclaim industry (GM Air = 48 µg/m 3 , GM Hand-End = 130 µg/sample) and in the job of working with molten BPA-filled wax (GM Air = 43 µg/m 3 , GM Hand-End = 180 µg/sample), and lowest in the phenolic resins industry (GM Air = 0.85 µg/m 3 , GM Hand-End = 0.43 µg/sample) and in the job of flaking phenolic resins (GM AIR = 0.62 µg/m 3 , GM Hand-End = 0.38 µg/sample). Determinants of increased BPA air concentration were industry, handling BPA containers, spilling BPA, and spending ≥50% of the shift in production areas; increasing age was associated with lower air concentrations. BPA hand exposure determinants were influenced by high values for two workers; for all other workers, tasks involving contact with BPA-containing materials and spending ≥50% of the shift in production areas were associated with increased BPA hand levels. Surface wipe BPA levels were significantly lower in

  14. Quantitative Analysis of Organophosphate and Pyrethroid Insecticides, PyrethroidTransformation Products, Polybrominated Diphenyl Ethers and Bisphenol A in Residential Surface Wipe Samples

    Science.gov (United States)

    Surface wipe sampling is a frequently used technique for measuring persistent pollutants in residential environments. One characteristic of this form of sampling is the need to extract the entire wipe sample to achieve adequate sensitivity and to ensure representativeness. Most s...

  15. BERYLLIUM MEASUREMENT IN COMMERCIALLY AVAILABLE WET WIPES

    Energy Technology Data Exchange (ETDEWEB)

    Youmans-Mcdonald, L.

    2011-02-18

    Analysis for beryllium by fluorescence is now an established method which is used in many government-run laboratories and commercial facilities. This study investigates the use of this technique using commercially available wet wipes. The fluorescence method is widely documented and has been approved as a standard test method by ASTM International and the National Institute for Occupational Safety and Health (NIOSH). The procedure involves dissolution of samples in aqueous ammonium bifluoride solution and then adding a small aliquot to a basic hydroxybenzoquinoline sulfonate fluorescent dye (Berylliant{trademark} Inc. Detection Solution Part No. CH-2) , and measuring the fluorescence. This method is specific to beryllium. This work explores the use of three different commercial wipes spiked with beryllium, as beryllium acetate or as beryllium oxide and subsequent analysis by optical fluorescence. The effect of possible interfering metals such as Fe, Ti and Pu in the wipe medium is also examined.

  16. Beryllium Measurement In Commercially Available Wet Wipes

    International Nuclear Information System (INIS)

    Youmans-Mcdonald, L.

    2011-01-01

    Analysis for beryllium by fluorescence is now an established method which is used in many government-run laboratories and commercial facilities. This study investigates the use of this technique using commercially available wet wipes. The fluorescence method is widely documented and has been approved as a standard test method by ASTM International and the National Institute for Occupational Safety and Health (NIOSH). The procedure involves dissolution of samples in aqueous ammonium bifluoride solution and then adding a small aliquot to a basic hydroxybenzoquinoline sulfonate fluorescent dye (Berylliant(trademark) Inc. Detection Solution Part No. CH-2) , and measuring the fluorescence. This method is specific to beryllium. This work explores the use of three different commercial wipes spiked with beryllium, as beryllium acetate or as beryllium oxide and subsequent analysis by optical fluorescence. The effect of possible interfering metals such as Fe, Ti and Pu in the wipe medium is also examined.

  17. Measuring PM2.5, Ultrafine Particles, Nicotine Air and Wipe Samples Following the Use of Electronic Cigarettes.

    Science.gov (United States)

    Melstrom, Paul; Koszowski, Bartosz; Thanner, Meridith Hill; Hoh, Eunha; King, Brian; Bunnell, Rebecca; McAfee, Tim

    2017-09-01

    Few studies have examined the extent of inhalation or dermal contact among bystanders following short-term, secondhand e-cigarette exposure. Measure PM2.5 (particles e-cigarette exposure. E-cigarettes were used ad libitum by three experienced users for 2 hours during two separate sessions (disposable e-cigarettes, then tank-style e-cigarettes, or "tanks") in a 1858 ft3 room. We recorded: uncorrected PM2.5 (using SidePak); UF (using P-Trak); air nicotine concentrations (using air samplers; SKC XAD-4 canisters); ambient air exchange rate (using an air capture hood). Wipe samples were taken by wiping 100 cm2 room surfaces pre- and post- both sessions, and clean cloth wipes were worn during the exposure and collected at the end. Uncorrected PM2.5 and UF were higher (p e-cigarette use can produce: elevated PM2.5; elevated UF; nicotine in the air; and accumulation of nicotine on surfaces and clothing. Short-term indoor e-cigarette use produced accumulation of nicotine on surfaces and clothing, which could lead to dermal exposure to nicotine. Short-term e-cigarette use produced elevated PM2.5 and ultrafine particles, which could lead to secondhand inhalation of these particles and any chemicals associated with them by bystanders. We measured significant differences in PM2.5 and ultrafine particles between disposable e-cigarettes and tank-style e-cigarettes, suggesting a difference in the exposure profiles of e-cigarette products. Published by Oxford University Press on behalf of Society for Research on Nicotine and Tobacco 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  18. Development and validation of a highly sensitive gas chromatographic-mass spectrometric screening method for the simultaneous determination of nanogram levels of fentanyl, sufentanil and alfentanil in air and surface contamination wipes.

    Science.gov (United States)

    Van Nimmen, Nadine F J; Veulemans, Hendrik A F

    2004-05-07

    A highly sensitive gas chromatographic-mass spectrometric (GC-MS) analytical method for the determination of the opioid narcotics fentanyl, alfentanil, and sufentanil in industrial hygiene personal air samples and surface contamination wipes was developed and comprehensively validated. Sample preparation involved a single step extraction of the samples with methanol, fortified with a fixed amount of the penta-deuterated analogues of the opioid narcotics as internal standard. The GC-MS analytical procedure using selected ion monitoring (SIM) was shown to be highly selective. Linearity was shown for levels of extracted wipe and air samples corresponding to at least 0.1-2 times their surface contamination limit (SCL) and accordingly to 0.1-2 times their time weighted average occupational exposure limit (OEL-TWA) based on a full shift 9601 air sample. Extraction recoveries were determined for spiked air samples and surface wipes and were found to be quantitative for both sampling media in the entire range studied. The air sampling method's limit of detection (LOD) was determined to be 0.4 ng per sample for fentanyl and sufentanil and 1.6 ng per sample for alfentanil, corresponding to less than 1% of their individual OEL for a full shift air sample (9601). The limit of quantification (LOQ) was found to be 1.4, 1.2, and 5.0 ng per filter for fentanyl, sufentanil, and alfentanil, respectively. The wipe sampling method had LODs of 4 ng per wipe for fentanyl and sufentanil and 16 ng per wipe for alfentanil and LOQs of respectively, 14, 12, and 50 ng per wipe. The analytical intra-assay precision of the air sampling and wipe sampling method, defined as the coefficient of variation on the analytical result of six replicate spiked media was below 10 and 5%, respectively, for all opioids at all spike levels. Accuracy expressed as relative error was determined to be below 10%, except for alfentanil at the lowest spike level (-13.1%). The stability of the opioids during simulated

  19. Satisfaction and convenience of using terpenoid-impregnated eyelid wipes and teaching method in people without blepharitis.

    Science.gov (United States)

    Qiu, Tian Yu; Yeo, Sharon; Tong, Louis

    2018-01-01

    Demodex infestations cause blepharitis and are difficult to treat. Recently, a new type of eyelid wipes with terpenoids has been found effective. We aim to evaluate patient satisfaction after short-term use and compare two teaching modalities on the techniques of use. Eligible participants were taught to use eyelid wipes (Cliradex ® ) by either live or online video demonstration based on random allocation. Participants used the wipes twice daily for a week. All participants had prior evaluation of socioeconomic status, dry eye symptoms, and meibomian gland features. After 1 week, competence of use was assessed by participants showing their technique to the investigator, and a questionnaire on comfort, ease, and convenience of use was administered. Higher scores indicate greater satisfaction, and these levels are compared among the two teaching modalities using chi square. A total of 50 participants were recruited, with a mean age of 42±16 years, and 88% of the participants were females. Overall, median comfort level was 4.0 (range: 1-6), ease level was 5.0 (3-6), and convenience level was 5.0 (2-6). Median stinging was 2.0 (1-4), which corresponded to some but mild stinging. The median competence level was 4.0 (2-4), which corresponded to excellent competence. These satisfactory levels (ease, comfort, and convenience) experienced were not significantly associated with different socioeconomic indicators, that is, housing type, income, highest education level, and were not different between teaching methods ( p >0.05). Short-term use of Cliradex eyelid wipes seems to be acceptable to most people. The teaching instructions before using these wipes were equally effective - whether live or online video demonstration was used.

  20. EPA Method 3135.2I: Cyanide, Total and Amenable in Aqueous and Solid Samples Automated Colorimetric With Manual Digestion

    Science.gov (United States)

    This method describes procedures for preparation and analysis of solid, water and wipe samples for detection and measurement of cyanide amendable to chlorination using acid digestion and spectrophotometry.

  1. Sampling methods

    International Nuclear Information System (INIS)

    Loughran, R.J.; Wallbrink, P.J.; Walling, D.E.; Appleby, P.G.

    2002-01-01

    Methods for the collection of soil samples to determine levels of 137 Cs and other fallout radionuclides, such as excess 210 Pb and 7 Be, will depend on the purposes (aims) of the project, site and soil characteristics, analytical capacity, the total number of samples that can be analysed and the sample mass required. The latter two will depend partly on detector type and capabilities. A variety of field methods have been developed for different field conditions and circumstances over the past twenty years, many of them inherited or adapted from soil science and sedimentology. The use of them inherited or adapted from soil science and sedimentology. The use of 137 Cs in erosion studies has been widely developed, while the application of fallout 210 Pb and 7 Be is still developing. Although it is possible to measure these nuclides simultaneously, it is common for experiments to designed around the use of 137 Cs along. Caesium studies typically involve comparison of the inventories found at eroded or sedimentation sites with that of a 'reference' site. An accurate characterization of the depth distribution of these fallout nuclides is often required in order to apply and/or calibrate the conversion models. However, depending on the tracer involved, the depth distribution, and thus the sampling resolution required to define it, differs. For example, a depth resolution of 1 cm is often adequate when using 137 Cs. However, fallout 210 Pb and 7 Be commonly has very strong surface maxima that decrease exponentially with depth, and fine depth increments are required at or close to the soil surface. Consequently, different depth incremental sampling methods are required when using different fallout radionuclides. Geomorphic investigations also frequently require determination of the depth-distribution of fallout nuclides on slopes and depositional sites as well as their total inventories

  2. wait and wipe

    African Journals Online (AJOL)

    and wipe strategy” as an alternative to circumcision for HIV prevention. In this paper, we argue that waiting for ten minutes and wiping with a dry cloth does not prevent men from becoming infected by HIV. We ... HIV infected despite having reported no sex or 100% condom .... In a qualitative study conducted in Kenya, men.

  3. Comprehensive Study of Human External Exposure to Organophosphate Flame Retardants via Air, Dust, and Hand Wipes: The Importance of Sampling and Assessment Strategy.

    Science.gov (United States)

    Xu, Fuchao; Giovanoulis, Georgios; van Waes, Sofie; Padilla-Sanchez, Juan Antonio; Papadopoulou, Eleni; Magnér, Jorgen; Haug, Line Småstuen; Neels, Hugo; Covaci, Adrian

    2016-07-19

    We compared the human exposure to organophosphate flame retardants (PFRs) via inhalation, dust ingestion, and dermal absorption using different sampling and assessment strategies. Air (indoor stationary air and personal ambient air), dust (floor dust and surface dust), and hand wipes were sampled from 61 participants and their houses. We found that stationary air contains higher levels of ΣPFRs (median = 163 ng/m(3), IQR = 161 ng/m(3)) than personal air (median = 44 ng/m(3), IQR = 55 ng/m(3)), suggesting that the stationary air sample could generate a larger bias for inhalation exposure assessment. Tris(chloropropyl) phosphate isomers (ΣTCPP) accounted for over 80% of ΣPFRs in both stationary and personal air. PFRs were frequently detected in both surface dust (ΣPFRs median = 33 100 ng/g, IQR = 62 300 ng/g) and floor dust (ΣPFRs median = 20 500 ng/g, IQR = 30 300 ng/g). Tris(2-butoxylethyl) phosphate (TBOEP) accounted for 40% and 60% of ΣPFRs in surface and floor dust, respectively, followed by ΣTCPP (30% and 20%, respectively). TBOEP (median = 46 ng, IQR = 69 ng) and ΣTCPP (median = 37 ng, IQR = 49 ng) were also frequently detected in hand wipe samples. For the first time, a comprehensive assessment of human exposure to PFRs via inhalation, dust ingestion, and dermal absorption was conducted with individual personal data rather than reference factors of the general population. Inhalation seems to be the major exposure pathway for ΣTCPP and tris(2-chloroethyl) phosphate (TCEP), while participants had higher exposure to TBOEP and triphenyl phosphate (TPHP) via dust ingestion. Estimated exposure to ΣPFRs was the highest with stationary air inhalation (median =34 ng·kg bw(-1)·day(-1), IQR = 38 ng·kg bw(-1)·day(-1)), followed by surface dust ingestion (median = 13 ng·kg bw(-1)·day(-1), IQR = 28 ng·kg bw(-1)·day(-1)), floor dust ingestion and personal air inhalation. The median dermal exposure on hand wipes was 0.32 ng·kg bw(-1)·day(-1) (IQR

  4. Contamination monitoring of Na 131 I levels in therapy unit of Research Institute for Nuclear Medicine, Tehran University of Medical Sciences by indirect method (Wipe test)

    International Nuclear Information System (INIS)

    Beiki, D.; Shahhosseini, S.; Eftekhari, M.; Takavar, A.; Fard-Esfahani, A.

    2003-01-01

    Contamination with radiopharmaceuticals in nuclear medicine centres in addition to being a health concern requires time consuming decontamination efforts. According to Nuclear Regulatory Commission Contamination should be monitored in nuclear medicine centers where radiopharmaceuticals are prepared and administrated at the end of each working session; otherwise, contamination spread to other areas not only equipment but also personnel and other people will be expected. The wipe test for the presence of radioactivity is accomplished by wiping the surface over an area approximately 100 cm 2 with an absorbent paper, then counting it in an appropriate radiation detector. In this study, contamination monitoring of patient's rooms (4 rooms), entrance corridor, patient's corridor, waiting room, control room (nursing station), radiopharmaceutical storage room in therapy unit of Research Institute for Nuclear Medicine, Shariati hospital was performed by indirect method. Based on the results, some areas including storage room were contaminated. There was also a direct relationship between dose administrated and levels of contamination in patient's rooms. Regarding high uptake of iodine by thyroid gland and damaging effects of Na 131 I, weekly wipe tests are required to determine the level of contamination. Patient's rooms after discharging the patients and before re hospitalization specially should be checked. If these tests reveal contamination over standard levels, appropriate decontamination procedures should be carried out immediately

  5. Arsenic levels in wipe samples collected from play structures constructed with CCA-treated wood: Impact on exposure estimates

    Energy Technology Data Exchange (ETDEWEB)

    Barraj, Leila M. [Chemical Regulation and Food Safety, Exponent, Inc., Suite 1100, 1150 Connecticut Ave., NW, Washington, DC 20036 (United States)], E-mail: lbarraj@exponent.com; Scrafford, Carolyn G. [Chemical Regulation and Food Safety, Exponent, Inc., Suite 1100, 1150 Connecticut Ave., NW, Washington, DC 20036 (United States); Eaton, W. Cary [RTI International, 3040 Cornwallis Road, Research Triangle Park, NC 27709 (United States); Rogers, Robert E.; Jeng, Chwen-Jyh [Toxcon Health Sciences Research Centre Inc., 9607 - 41 Avenue, Edmonton, Alberta, T6E 5X7 (Canada)

    2009-04-01

    Lumber treated with chromated copper arsenate (CCA) has been used in residential outdoor wood structures and playgrounds. The U.S. EPA has conducted a probabilistic assessment of children's exposure to arsenic from CCA-treated structures using the Stochastic Human Exposure and Dose Simulation model for the wood preservative scenario (SHEDS-Wood). The EPA assessment relied on data from an experimental study using adult volunteers and designed to measure arsenic in maximum hand and wipe loadings. Analyses using arsenic handloading data from a study of children playing on CCA-treated play structures in Edmonton, Canada, indicate that the maximum handloading values significantly overestimate the exposure that occurs during actual play. The objective of our paper is to assess whether the dislodgeable arsenic residues from structures in the Edmonton study are comparable to those observed in other studies and whether they support the conclusion that the values derived by EPA using modeled maximum loading values overestimate hand exposures. We compared dislodgeable arsenic residue data from structures in the playgrounds in the Edmonton study to levels observed in studies used in EPA's assessment. Our analysis showed that the dislodgeable arsenic levels in the Edmonton playground structures are similar to those in the studies used by EPA. Hence, the exposure estimates derived using the handloading data from children playing on CCA-treated structures are more representative of children's actual exposures than the overestimates derived by EPA using modeled maximum values. Handloading data from children playing on CCA-treated structures should be used to reduce the uncertainty of modeled estimates derived using the SHEDS-Wood model.

  6. Sampling by sponge wipe or skin excision for recovery of inoculated Salmonella and Campylobacter from defeathered broiler carcasses

    Science.gov (United States)

    Broilers may carry Salmonella and Campylobacter on inner and outer surfaces upon arrival at the slaughter plant and carcasses can be further contaminated during commercial processing. A sensitive, non-destructive, repeatable sampling method would be useful to test carcasses for levels of bacteria b...

  7. Wipe sampling of amphetamine-type stimulants and recreational drugs on selected household surfaces with analysis by ultra-performance liquid chromatography quadrupole time-of-flight mass spectrometry

    International Nuclear Information System (INIS)

    Madireddy, Sri Bharat; Bodeddula, Vanaja Reddy; Mansani, Sravan Kumar; Wells, Martha J.M.; Boles, Jeffrey O.

    2013-01-01

    Highlights: • Degree of sorption of eight drugs on eleven countertop surfaces was investigated. • Surface composition, volatility and solvent composition played a role in sorption. • Solvent-dependent migration was a key factor of consideration during remediation. • SPME-assisted volatility studies provided evidence for varying degrees of recovery. • Rapid three minute UPLC-QTOF method was developed to quantify the eight compounds. -- Abstract: Sorption characteristics of eight drugs related to recreational and clandestine activity—amphetamine, cocaine, heroin, N-formyl amphetamine, N-formyl methamphetamine, methamphetamine, 3, 4-methylenedioxymethamphetamine (MDMA), and pseudoephedrine—were evaluated on selected kitchen countertop surfaces. Methanol-dampened Whatman™ 40 filter paper wipes were used to collect samples from eleven surfaces including alkyd resin, ceramic tiles, glass, granite, laminate, limestone, marble, quartz compac, quartz real, soap stone, and stainless steel. The filter paper wipes were analyzed by a rapid three-minute UPLC-QTOF method, following ammonium acetate buffer (pH 5.8–6.2) extraction. The average percentage recoveries after 15 h of exposure to the surface materials tested, was found to be highest for cocaine and MDMA and lowest for amphetamine and methamphetamine. Among the eleven countertop surfaces, overall recoveries for marble were observed to be the least, whereas soapstone, quartz compac and stainless steel were among the highest. Scanning electron microscopic images of the surfaces provided a unique view of surface irregularities that potentially influenced drug recovery. Aging, migration, solvent composition, and volatility were examined. The variation in recovery of drugs was attributed to four key factors: compound volatility, surface composition, surface—compound interaction, and solvent composition

  8. Wipe sampling of amphetamine-type stimulants and recreational drugs on selected household surfaces with analysis by ultra-performance liquid chromatography quadrupole time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Madireddy, Sri Bharat; Bodeddula, Vanaja Reddy; Mansani, Sravan Kumar; Wells, Martha J.M.; Boles, Jeffrey O., E-mail: jboles@tntech.edu

    2013-06-15

    Highlights: • Degree of sorption of eight drugs on eleven countertop surfaces was investigated. • Surface composition, volatility and solvent composition played a role in sorption. • Solvent-dependent migration was a key factor of consideration during remediation. • SPME-assisted volatility studies provided evidence for varying degrees of recovery. • Rapid three minute UPLC-QTOF method was developed to quantify the eight compounds. -- Abstract: Sorption characteristics of eight drugs related to recreational and clandestine activity—amphetamine, cocaine, heroin, N-formyl amphetamine, N-formyl methamphetamine, methamphetamine, 3, 4-methylenedioxymethamphetamine (MDMA), and pseudoephedrine—were evaluated on selected kitchen countertop surfaces. Methanol-dampened Whatman™ 40 filter paper wipes were used to collect samples from eleven surfaces including alkyd resin, ceramic tiles, glass, granite, laminate, limestone, marble, quartz compac, quartz real, soap stone, and stainless steel. The filter paper wipes were analyzed by a rapid three-minute UPLC-QTOF method, following ammonium acetate buffer (pH 5.8–6.2) extraction. The average percentage recoveries after 15 h of exposure to the surface materials tested, was found to be highest for cocaine and MDMA and lowest for amphetamine and methamphetamine. Among the eleven countertop surfaces, overall recoveries for marble were observed to be the least, whereas soapstone, quartz compac and stainless steel were among the highest. Scanning electron microscopic images of the surfaces provided a unique view of surface irregularities that potentially influenced drug recovery. Aging, migration, solvent composition, and volatility were examined. The variation in recovery of drugs was attributed to four key factors: compound volatility, surface composition, surface—compound interaction, and solvent composition.

  9. Study on the wiping gas jet in continuous galvanizing line

    Science.gov (United States)

    Kweon, Yong-Hun; Kim, Heuy-Dong

    2011-09-01

    In the continuous hot-dip galvanizing process, the gas-jet wiping is used to control the coating thickness of moving steel strip. The high speed gas-jet discharged from the nozzle slot impinges on the strip, and at this moment, wipes the liquid coating layer dragged by a moving strip. The coating thickness is generally influenced on the flow characteristics of wiping gas-jet such as the impinging pressure distribution, pressure gradient and shear stress distribution on the surface of strip. The flow characteristics of wiping gas-jet mentioned above depends upon considerably both the process operating conditions such as the nozzle pressure, nozzle-to-strip distance and line speed, and the geometry of gas-jet wiping apparatus such as the height of nozzle slot. In the present study, the effect of the geometry of nozzle on the coating thickness is investigated with the help of a computational fluid dynamics method. The height of nozzle slot is varied in the range of 0.6mm to 1.7mm. A finite volume method (FVM) is employed to solve two-dimensional, steady, compressible Navier-Stokes equations. Based upon the results obtained, the effect of the height of nozzle slot in the gas-jet wiping process is discussed in detail. The computational results show that for a given standoff distance between the nozzle to the strip, the effective height of nozzle slot exists in achieving thinner coating thickness.

  10. On wiping the interior walls of 37-mm closed-face cassettes: an OSHA perspective.

    Science.gov (United States)

    Hendricks, Warren; Stones, Fern; Lillquist, Dean

    2009-12-01

    As early as 1976, Occupational Safety and Health Administration (OSHA) methods for analyzing metal samples collected using 37-mm polystyrene closed-face cassettes specified that any loose dust be transferred from the cassette to the digestion vessel, that the cassette be rinsed, and that, if necessary, the cassette be wiped out to help ensure that all particles that enter the cassette are included along with the filter as part of the sample for analysis. OSHA analytical methods for metal analysis were recently revised to explicitly require cassette wiping for all metal samples. This change was based on policy that any material entering the collection device constitutes part of the sample and on OSHA Salt Lake Technical Center research showing that invisible residue on the cassette walls can significantly contribute to the total sample results reported. OSHA procedures are consistent with guidance given in the NIOSH Manual of Analytical Methods. This guidance concludes that internal deposits in sampling cassettes should be included in the analysis and that one way to accomplish this would be to wipe or wash the internal surfaces of the cassette and include the material along with the filter for analysis.

  11. Evaluation of environmental sampling methods for detection of Salmonella enterica in a large animal veterinary hospital.

    Science.gov (United States)

    Goeman, Valerie R; Tinkler, Stacy H; Hammac, G Kenitra; Ruple, Audrey

    2018-04-01

    Environmental surveillance for Salmonella enterica can be used for early detection of contamination; thus routine sampling is an integral component of infection control programs in hospital environments. At the Purdue University Veterinary Teaching Hospital (PUVTH), the technique regularly employed in the large animal hospital for sample collection uses sterile gauze sponges for environmental sampling, which has proven labor-intensive and time-consuming. Alternative sampling methods use Swiffer brand electrostatic wipes for environmental sample collection, which are reportedly effective and efficient. It was hypothesized that use of Swiffer wipes for sample collection would be more efficient and less costly than the use of gauze sponges. A head-to-head comparison between the 2 sampling methods was conducted in the PUVTH large animal hospital and relative agreement, cost-effectiveness, and sampling efficiency were compared. There was fair agreement in culture results between the 2 sampling methods, but Swiffer wipes required less time and less physical effort to collect samples and were more cost-effective.

  12. In vitro prediction of in vivo skin damage associated with the wiping of dry tissue against skin.

    Science.gov (United States)

    Koenig, David W; Dvoracek, Barb; Vongsa, Rebecca

    2013-02-01

    The ideal gentle cleansing product is one that effectively removes soils while minimizing damage to the skin. Thus, measuring physical abrasion caused by cleansing tissues is critical to the continued development of gentle cleansing products. Current analysis of cleansing materials for skin gentleness is time consuming and requires expensive human subject testing. This report describes the development of a rapid and inexpensive bench assay for the assessment of skin abrasion caused by wiping. Coefficient of friction (COF) evaluations using bench methods were compared with results from clinical studies of repeated wiping and with confocal visualizations of excised skin. A Monitor/Slip and Friction instrument (model 32-06; TMI, Amityville, NY, USA) was used to measure tissue friction on simulated skin (Vitro-Skin, N19-5X; IMS, Milford, CT, USA). Clinical data from a 4-day repetitive forearm wiping study measuring transepidermal water loss (TEWL) in 30 subjects was compared with results from the bench top assay. In addition, excised skin samples were also treated using the COF bench assay and examined using confocal microscopy to visualize stratum corneum damage caused by wiping. Using the bench COF assay, we were able to distinguish between bath tissue codes by comparing average static friction value (ASFV) for the test codes, where lower ASFV indicated less abrasive tissue. The ASFV followed the same gentleness trend observed in the clinical study. Confocal microscopy of excised skin wiped with the same materials indicated stratum corneum damage consistent with the bench COF and clinical TEWL observations. We observed significant correlation between bench and clinical methods for measuring skin damage caused by wiping of skin with tissue. The bench method will facilitate rapid and inexpensive skin gentleness assessment of cleansing materials. © 2012 John Wiley & Sons A/S.

  13. Sampling system and method

    Science.gov (United States)

    Decker, David L.; Lyles, Brad F.; Purcell, Richard G.; Hershey, Ronald Lee

    2013-04-16

    The present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit.

  14. Valuation of cloths for decontamination by wiping

    International Nuclear Information System (INIS)

    Rankin, W.N.; Reif, D.J.; Fink, S.D.; Luckenbach, R.L.

    1990-01-01

    Treated polyester cloth was evaluated in laboratory-scale and larger-scale tests as an alternative to atomic wipes and cotton cloth for use in decontamination by wiping. The advantages of the treated polyester are as follows: Does not react with nitric acid to form unstable product, More fire resistant, Less volume of radioactive waste generated (versus atomic wipes), and Product can be recovered by soaking the polyester cloths in nitric acid. Results are that even though treated polyester wiping cloths are slightly less effective than atomic wipes and cotton cloth, its many other benefits greatly outweigh this slight disadvantage. 1 ref., 5 figs

  15. Independent random sampling methods

    CERN Document Server

    Martino, Luca; Míguez, Joaquín

    2018-01-01

    This book systematically addresses the design and analysis of efficient techniques for independent random sampling. Both general-purpose approaches, which can be used to generate samples from arbitrary probability distributions, and tailored techniques, designed to efficiently address common real-world practical problems, are introduced and discussed in detail. In turn, the monograph presents fundamental results and methodologies in the field, elaborating and developing them into the latest techniques. The theory and methods are illustrated with a varied collection of examples, which are discussed in detail in the text and supplemented with ready-to-run computer code. The main problem addressed in the book is how to generate independent random samples from an arbitrary probability distribution with the weakest possible constraints or assumptions in a form suitable for practical implementation. The authors review the fundamental results and methods in the field, address the latest methods, and emphasize the li...

  16. A rapid alpha dosimeter for measuring nasal cavity wipe matter

    International Nuclear Information System (INIS)

    Tuo, Xianguo; Mu, Keliang; Zhong, Hongmei; Yang, Guoshan; Yuan, Yong

    2008-01-01

    Full text: It is necessary for people who work in the special condition to know whether the alpha radiation is inhaled through detecting quickly nasal cavity wipe matter. This measure method requires that the dosimeter must be portable and easy to operate, and be able to overcome some disadvantages, such as high environment background, few sample quantity, short measure time, and so on. Based on the above requests, a new intelligent portable system is developed for measuring alpha radiated degree, which is suitable for solid wiping matter detected of which diameter is smaller than 20 mm. This system is mainly made up of the detector, self- circumrotating sample shelf, I/A converter, signal gathering and processing system, power supply etc. The system chooses PIPS (Planar Implanted Passivated Silicon) detector which is a designed logical signal gathering hardware. The detector is with small volume, high efficiency and good resolution. PIPS detector doesn't need working gas and is easy to use compared with gas ionization chamber detector. The self-circumrotating sample shelf carries on measuring samples cubically and this improves the accuracy. The system uses compensating adjustment technology to remove background, automatically identify and compensate for radon, thoron and progeny interference, and is able to obtain the reliable measurement result. And the power for this system is supplied simultaneously by 220 V AV power and rechargeable Li-battery supply; it also has a mobile storage for more environments. The dosimeter is used to measure the samples of which diameters are 10∼20 mm , the result of tests shows that: detection efficiency ≥ 30%, background count ≤ 0.2 cpm, stability ≤ 0.3% / h, working temperature -10∼40 C degrees. The parameters of the system basically meet the rapid measurement in a special environment, so it has valuable application prospect in the field of environment, laboratories, and nuclear facilities etc. (author)

  17. Radioactive air sampling methods

    CERN Document Server

    Maiello, Mark L

    2010-01-01

    Although the field of radioactive air sampling has matured and evolved over decades, it has lacked a single resource that assimilates technical and background information on its many facets. Edited by experts and with contributions from top practitioners and researchers, Radioactive Air Sampling Methods provides authoritative guidance on measuring airborne radioactivity from industrial, research, and nuclear power operations, as well as naturally occuring radioactivity in the environment. Designed for industrial hygienists, air quality experts, and heath physicists, the book delves into the applied research advancing and transforming practice with improvements to measurement equipment, human dose modeling of inhaled radioactivity, and radiation safety regulations. To present a wide picture of the field, it covers the international and national standards that guide the quality of air sampling measurements and equipment. It discusses emergency response issues, including radioactive fallout and the assets used ...

  18. Allergenic Ingredients in Personal Hygiene Wet Wipes.

    Science.gov (United States)

    Aschenbeck, Kelly A; Warshaw, Erin M

    Wet wipes are a significant allergen source for anogenital allergic contact dermatitis. The aim of the study was to calculate the frequency of potentially allergenic ingredients in personal hygiene wet wipes. Ingredient lists from brand name and generic personal hygiene wet wipes from 4 large retailers were compiled. In the 54 personal hygiene wet wipes evaluated, a total of 132 ingredients were identified (average of 11.9 ingredients per wipe). The most common ingredients were Aloe barbadensis (77.8%), citric acid (77.8%), fragrance (72.2%), sorbic acid derivatives (63.0%), tocopherol derivatives (63.0%), glycerin (59.3%), phenoxyethanol (55.6%), disodium cocoamphodiacetate (53.7%), disodium ethylenediaminetetraacetic acid (EDTA) (42.6%), propylene glycol (42.6%), iodopropynyl butylcarbamate (40.7%), chamomile extracts (38.9%), sodium benzoate (35.2%), bronopol (22.2%), sodium citrate (22.2%), lanolin derivatives (20.4%), parabens (20.4%), polyethylene glycol derivatives (18.5%), disodium phosphate (16.7%), dimethylol dimethyl hydantoin (DMDM) (14.8%), and cocamidopropyl propylene glycol (PG)-dimonium chloride phosphate (11.1%). Of note, methylisothiazolinone (5.6%) was uncommon; methylchloroisothiazolinone was not identified in the personal hygiene wet wipes examined. There are many potential allergens in personal hygiene wet wipes, especially fragrance and preservatives.

  19. Simultaneous Determination of Alkoxyalcohols in Wet Wipes Using Static Headspace Gas Chromatography and Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So Jin; Pyo, Hee Soo; Chung, Bong Chul; Lee, Jeon Gae [KIST, Seoul (Korea, Republic of); Kim, Hai Dong [Kyung Hee University, Seoul (Korea, Republic of)

    2014-09-15

    Alkoxyalcohols are used as solvents or preservatives in various consumer products such as wet wipes. The metabolites of alkoxyalcohols are known to be chronically toxic and carcinogenic to animals. Thus, an analytical method is needed to monitor alkoxyalcohols in wet wipes. The aim of this study was to develop a simultaneous analytical method for 14 alkoxyalcohols using headspace gas chromatography coupled with mass spectrometry to analyze the wet wipes. This method was developed by comparing with various headspace extraction parameters. The linear calibration curves were obtained for the method (r2 > 0.995). The limit of detection of alkoxyalcohols ranged from 2 to 200 ng mL-1. The precision of the determinative method was less than 18.20% coefficient of variation both intra and inter days. The accuracy of the method ranged from 82.86% to 119.83%. (2-Methoxymethylethoxy)propanol, 2-phenoxyethanol, and 1-phenoxy-2-propanol were mainly detected in wet wipes.

  20. The development of a new three-step protocol to determine the efficacy of disinfectant wipes on surfaces contaminated with Staphylococcus aureus.

    Science.gov (United States)

    Williams, G J; Denyer, S P; Hosein, I K; Hill, D W; Maillard, J-Y

    2007-12-01

    We developed a three-step protocol to quantify the efficacy of disinfectant wipes, their ability to remove and prevent microbial transfer from surfaces and their overall antimicrobial activity. Meticillin-resistant (MRSA) or -susceptible (MSSA) Staphylococcus aureus (6-7 log(10)cfu) were inoculated onto stainless steel discs with or without organic load and dried. Grapefruit extract-containing test wipes and unmedicated control wipes were used. In step 1, wipes were mechanically rotated against surfaces for 10s at 60rpm, exerting a weight of 100+/-5g. Bacterial removal was assessed by transferring the steel discs to neutraliser, resuspending and counting remaining bacteria. In step 2, bacterial transfer from wipes was assessed by eight consecutive mechanical adpression transfers to agar/neutraliser plates. Step 3 was the measurement of antimicrobial activity by direct inoculation of the wipes for 10s followed by neutralisation and enumeration. Test wipes achieved a significantly higher bacterial cell removal than control wipes on all surfaces (P<0.05). The low bactericidal activity of the wipes (<1 log(10) reduction when directly inoculated) and the subsequent survival of bacteria on the wipes, however, led to repeated microbial transfer when initially high contamination levels were present. There were no differences between MRSA and MSSA in removal, transfer or antimicrobial activity. The three-step method is a useful tool for developing future guidelines to assess the ability of wipes to disinfect surfaces.

  1. A method of language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik; Hengeveld, Kees

    1993-01-01

    In recent years more attention is paid to the quality of language samples in typological work. Without an adequate sampling strategy, samples may suffer from various kinds of bias. In this article we propose a sampling method in which the genetic criterion is taken as the most important: samples...... to determine how many languages from each phylum should be selected, given any required sample size....

  2. A method of language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik; Hengeveld, Kees

    1993-01-01

    In recent years more attention is paid to the quality of language samples in typological work. Without an adequate sampling strategy, samples may suffer from various kinds of bias. In this article we propose a sampling method in which the genetic criterion is taken as the most important: samples...... created with this method will reflect optimally the diversity of the languages of the world. On the basis of the internal structure of each genetic language tree a measure is computed that reflects the linguistic diversity in the language families represented by these trees. This measure is used...... to determine how many languages from each phylum should be selected, given any required sample size....

  3. Mathematical modeling of wiped-film evaporators

    International Nuclear Information System (INIS)

    Sommerfeld, J.T.

    1976-05-01

    A mathematical model and associated computer program were developed to simulate the steady-state operation of wiped-film evaporators for the concentration of typical waste solutions produced at the Savannah River Plant. In this model, which treats either a horizontal or a vertical wiped-film evaporator as a plug-flow device with no backmixing, three fundamental phenomena are described: sensible heating of the waste solution, vaporization of water, and crystallization of solids from solution. Physical property data were coded into the computer program, which performs the calculations of this model. Physical properties of typical waste solutions and of the heating steam, generally as analytical functions of temperature, were obtained from published data or derived by regression analysis of tabulated or graphical data. Preliminary results from tests of the Savannah River Laboratory semiworks wiped-film evaporators were used to select a correlation for the inside film heat transfer coefficient. This model should be a useful aid in the specification, operation, and control of the full-scale wiped-film evaporators proposed for application under plant conditions. In particular, it should be of value in the development and analysis of feed-forward control schemes for the plant units. Also, this model can be readily adapted, with only minor changes, to simulate the operation of wiped-film evaporators for other conceivable applications, such as the concentration of acid wastes

  4. Validation and comparison of two sampling methods to assess dermal exposure to drilling fluids and crude oil.

    Science.gov (United States)

    Galea, Karen S; McGonagle, Carolyn; Sleeuwenhoek, Anne; Todd, David; Jiménez, Araceli Sánchez

    2014-06-01

    Dermal exposure to drilling fluids and crude oil is an exposure route of concern. However, there have been no published studies describing sampling methods or reporting dermal exposure measurements. We describe a study that aimed to evaluate a wipe sampling method to assess dermal exposure to an oil-based drilling fluid and crude oil, as well as to investigate the feasibility of using an interception cotton glove sampler for exposure on the hands/wrists. A direct comparison of the wipe and interception methods was also completed using pigs' trotters as a surrogate for human skin and a direct surface contact exposure scenario. Overall, acceptable recovery and sampling efficiencies were reported for both methods, and both methods had satisfactory storage stability at 1 and 7 days, although there appeared to be some loss over 14 days. The methods' comparison study revealed significantly higher removal of both fluids from the metal surface with the glove samples compared with the wipe samples (on average 2.5 times higher). Both evaluated sampling methods were found to be suitable for assessing dermal exposure to oil-based drilling fluids and crude oil; however, the comparison study clearly illustrates that glove samplers may overestimate the amount of fluid transferred to the skin. Further comparison of the two dermal sampling methods using additional exposure situations such as immersion or deposition, as well as a field evaluation, is warranted to confirm their appropriateness and suitability in the working environment. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  5. Surface dust wipes are the best predictors of blood leads in young children with elevated blood lead levels

    Energy Technology Data Exchange (ETDEWEB)

    Gulson, Brian, E-mail: brian.gulson@mq.edu.au [Graduate School of the Environment, Macquarie University, North Ryde NSW 2109 (Australia); CSIRO Earth Science and Resource Engineering, North Ryde NSW 2113 (Australia); Anderson, Phil [Information and Statistics Group, Australian Institute of Health and Welfare, Canberra ACT 2601 (Australia); Faculty of Health, University of Canberra, Canberra ACT 2601 (Australia); Taylor, Alan [Department of Psychology, Macquarie University, Sydney NSW 2109 (Australia)

    2013-10-15

    Background: As part of the only national survey of lead in Australian children, which was undertaken in 1996, lead isotopic and lead concentration measurements were obtained from children from 24 dwellings whose blood lead levels were ≥15 µg/dL in an attempt to determine the source(s) of their elevated blood lead. Comparisons were made with data for six children with lower blood lead levels (<10 µg/dL). Methods: Thermal ionisation and isotope dilution mass spectrometry were used to determine high precision lead isotopic ratios ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb and {sup 206}Pb/{sup 204}Pb) and lead concentrations in blood, dust from floor wipes, soil, drinking water and paint (where available). Evaluation of associations between blood and the environmental samples was based on the analysis of individual cases, and Pearson correlations and multiple regression analyses based on the whole dataset. Results and discussion: The correlations showed an association for isotopic ratios in blood and wipes (r=0.52, 95% CI 0.19–0.74), blood and soil (r=0.33, 95% CI −0.05–0.62), and blood and paint (r=0.56, 95% CI 0.09–0.83). The regression analyses indicated that the only statistically significant relationship for blood isotopic ratios was with dust wipes (B=0.65, 95% CI 0.35–0.95); there were no significant associations for lead concentrations in blood and environmental samples. There is a strong isotopic correlation of soils and house dust (r=0.53, 95% CI 0.20–0.75) indicative of a common source(s) for lead in soil and house dust. In contrast, as with the regression analyses, no such association is present for bulk lead concentrations (r=−0.003, 95% CI −0.37–0.36), the most common approach employed in source investigations. In evaluation of the isotopic results on a case by case basis, the strongest associations were for dust wipes and blood. -- Highlights: • Children with elevated blood lead ≥15 µg/dL compared with a group with <10

  6. SWOT ANALYSIS ON SAMPLING METHOD

    Directory of Open Access Journals (Sweden)

    CHIS ANCA OANA

    2014-07-01

    Full Text Available Audit sampling involves the application of audit procedures to less than 100% of items within an account balance or class of transactions. Our article aims to study audit sampling in audit of financial statements. As an audit technique largely used, in both its statistical and nonstatistical form, the method is very important for auditors. It should be applied correctly for a fair view of financial statements, to satisfy the needs of all financial users. In order to be applied correctly the method must be understood by all its users and mainly by auditors. Otherwise the risk of not applying it correctly would cause loose of reputation and discredit, litigations and even prison. Since there is not a unitary practice and methodology for applying the technique, the risk of incorrectly applying it is pretty high. The SWOT analysis is a technique used that shows the advantages, disadvantages, threats and opportunities. We applied SWOT analysis in studying the sampling method, from the perspective of three players: the audit company, the audited entity and users of financial statements. The study shows that by applying the sampling method the audit company and the audited entity both save time, effort and money. The disadvantages of the method are difficulty in applying and understanding its insight. Being largely used as an audit method and being a factor of a correct audit opinion, the sampling method’s advantages, disadvantages, threats and opportunities must be understood by auditors.

  7. Distance sampling methods and applications

    CERN Document Server

    Buckland, S T; Marques, T A; Oedekoven, C S

    2015-01-01

    In this book, the authors cover the basic methods and advances within distance sampling that are most valuable to practitioners and in ecology more broadly. This is the fourth book dedicated to distance sampling. In the decade since the last book published, there have been a number of new developments. The intervening years have also shown which advances are of most use. This self-contained book covers topics from the previous publications, while also including recent developments in method, software and application. Distance sampling refers to a suite of methods, including line and point transect sampling, in which animal density or abundance is estimated from a sample of distances to detected individuals. The book illustrates these methods through case studies; data sets and computer code are supplied to readers through the book’s accompanying website.  Some of the case studies use the software Distance, while others use R code. The book is in three parts.  The first part addresses basic methods, the ...

  8. Development, validation and testing of a skin sampling method for assessment of metal exposure.

    Science.gov (United States)

    Erfani, Behnaz; Midander, Klara; Lidén, Carola; Julander, Anneli

    2017-07-01

    Nickel, cobalt and chromium are frequent skin sensitizers. Skin exposure results in eczema in sensitized individuals, the risk being related to the skin dose. To develop a self-sampling method for quantification of skin exposure to metals, to validate the method, and to assess its feasibility. Defined metal doses (0.01-5 µg) were applied to the fingers of 5 participants. Skin areas (2 cm 2 ) were sampled with 1% HNO 3 , either as 0.1 ml on a swab, or as 0.5 ml on a wipe. Furthermore, 17 participants performed self-sampling by swab after 2 h of leisure activity. Samples were extracted in 1% HNO 3 and analysed by inductively coupled plasma mass spectrometry. The sampling efficiency by swab was 46%, as compared with 93% for acid wipe sampling, for all tested doses. Most metal from the skin dose was detected in the first swab (33-43%). Despite lower sampling efficiency by swab, skin doses of metals following 2 h of leisure activity without hand washing were quantified in all participants, and ranged from 0.0016 to 0.15 µg/cm 2 , from 0.00014 to -0.0020 µg/cm 2 and from 0.00048 to -0.027 µg/cm 2 for nickel, cobalt, and chromium, respectively. The results indicate a future potential of skin sampling by swab to detect and monitor metals on skin by self-sampling. This will contribute to better knowledge of metal skin exposure among dermatitis patients, workers, and the general population. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. An improved selective sampling method

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Iida, Nobuyuki; Watanabe, Tamaki

    1986-01-01

    The coincidence methods which are currently used for the accurate activity standardisation of radio-nuclides, require dead time and resolving time corrections which tend to become increasingly uncertain as countrates exceed about 10 K. To reduce the dependence on such corrections, Muller, in 1981, proposed the selective sampling method using a fast multichannel analyser (50 ns ch -1 ) for measuring the countrates. It is, in many ways, more convenient and possibly potentially more reliable to replace the MCA with scalers and a circuit is described employing five scalers; two of them serving to measure the background correction. Results of comparisons using our new method and the coincidence method for measuring the activity of 60 Co sources yielded agree-ment within statistical uncertainties. (author)

  10. Role of surface energy and nano-roughness in the removal efficiency of bacterial contamination by nonwoven wipes from frequently touched surfaces

    Science.gov (United States)

    Edwards, Nicholas W. M.; Best, Emma L.; Connell, Simon D.; Goswami, Parikshit; Carr, Chris M.; Wilcox, Mark H.; Russell, Stephen J.

    2017-12-01

    Healthcare associated infections (HCAIs) are responsible for substantial patient morbidity, mortality and economic cost. Infection control strategies for reducing rates of transmission include the use of nonwoven wipes to remove pathogenic bacteria from frequently touched surfaces. Wiping is a dynamic process that involves physicochemical mechanisms to detach and transfer bacteria to fibre surfaces within the wipe. The purpose of this study was to determine the extent to which systematic changes in fibre surface energy and nano-roughness influence removal of bacteria from an abiotic polymer surface in dry wiping conditions, without liquid detergents or disinfectants. Nonwoven wipe substrates composed of two commonly used fibre types, lyocell (cellulosic) and polypropylene, with different surface energies and nano-roughnesses, were manufactured using pilot-scale nonwoven facilities to produce samples of comparable structure and dimensional properties. The surface energy and nano-roughness of some lyocell substrates were further adjusted by either oxygen (O2) or hexafluoroethane (C2F6) gas plasma treatment. Static adpression wiping of an inoculated surface under dry conditions produced removal efficiencies of between 9.4% and 15.7%, with no significant difference (p < 0.05) in the relative removal efficiencies of Escherichia coli, Staphylococcus aureus or Enterococcus faecalis. However, dynamic wiping markedly increased peak wiping efficiencies to over 50%, with a minimum increase in removal efficiency of 12.5% and a maximum increase in removal efficiency of 37.9% (all significant at p < 0.05) compared with static wiping, depending on fibre type and bacterium. In dry, dynamic wiping conditions, nonwoven wipe substrates with a surface energy closest to that of the contaminated surface produced the highest E. coli removal efficiency, while the associated increase in fibre nano-roughness abrogated this trend with S. aureus and E. faecalis.

  11. Microbiological Sampling Methods and Sanitation of Edible Plants Grown on ISS

    Science.gov (United States)

    Parrish, Charles H. II; Khodadad, Christina L.; Garland, Nathaniel T.; Larson, Brian D.; Hummreick, Mary E.

    2013-01-01

    Pathogenic microbes on the surfaces of salad crops and growth chambers pose a threat to the health of crew on International Space Station. For astronauts to safely consume spacegrown vegetables produced in NASA's new vegetable production unit, VEGGIE, three technical challenges must be overcome: real-time sampling, microbiological analysis, and sanitation. Raphanus sativus cultivar Cherry Bomb II and Latuca sativa cultivar Outredgeous, two saled crops to be grown in VEGGIE, were inoculated with Salmonella enterica serovar Typhimurium (S. Typhimurium), a bacterium known to cause food-borne illness Tape- and swab-based sampling techniques were optimized for use in microgravity and assessed for effectiveness in recovery of bacteria from crop surfaces: Rapid pathogen detection and molecular analyses were performed via quantitative real-time polymerase chain reactiop using LightCycler® 480 and RAZOR® EX, a scaled-down instrument that is undergoing evaluation and testing for future flight hardware. These methods were compared with conventional, culture-based methods for the recovery of S. Typhimurium colonies. A sterile wipe saturated with a citric acid-based, food-grade sanitizer was applied to two different surface materials used in VEGGIE flight hardware that had been contaminated with the bacterium Pseudomonas aeruginosa,. another known human pathogen. To sanitize surfaces, wipes were saturated with either the sanitizer or sterile deionized water and applied to each surface. Colony forming units of P. aeruginosa grown on tryptic soy agar plates were enumerated from surface samples after sanitization treatments. Depending on the VEGGIE hardware material, 2- to 4.5-log10 reductions in colony-forming units were observed after sanitization. The difference in recovery of S. Typhimurium between tape- and swab- based sampling techniques was insignificant. RAZOR® EX rapidly detected S. Typhimurium present in both raw culture and extracted DNA samples.

  12. A pilot study to assess the effectiveness and cost of routine universal use of peracetic acid sporicidal wipes in a real clinical environment.

    Science.gov (United States)

    Saha, Avinandan; Botha, Stefan Louis; Weaving, Paul; Satta, Giovanni

    2016-11-01

    Peracetic acid sporicidal wipes have been shown to be an effective disinfectant, but in controlled test environments. Their high cost may restrict use. This pilot study investigated the efficacy and compared the costs of routine universal use of peracetic acid sporicidal wipes versus sporicidal quaternary ammonium compound and alcohol wipes in the disinfection of a hospital environment. The routine universal use of peracetic acid wipes (Clinell Sporicidal; GAMA Healthcare Ltd, London, UK) was allocated to a study ward, whereas the control ward continued with the use of quaternary ammonium compound wipes (Tuffie 5; Vernacare, Bolton, UK) and alcohol wipes (PDI Sani-Cloth 70; PDI, Flint, UK). Twenty high-touch areas in the 2 wards were sampled for the presence of indicator organisms. The weekly detection rates of indicator organisms and weekly healthcare associated infection (HCAI) rates in the 2 wards were compared and examined for decreasing trends over the trial period. The detection rates of indicator organisms and HCAI rates were not significantly different in the 2 wards, and did not decrease significantly over the trial period. However, the peracetic acid wipes seem to be more effective against gram-negative organisms but at a significantly higher cost. Further prospective studies are needed to assess the cost-effectiveness of peracetic acid wipes. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  13. Coupling methods for multistage sampling

    OpenAIRE

    Chauvet, Guillaume

    2015-01-01

    Multistage sampling is commonly used for household surveys when there exists no sampling frame, or when the population is scattered over a wide area. Multistage sampling usually introduces a complex dependence in the selection of the final units, which makes asymptotic results quite difficult to prove. In this work, we consider multistage sampling with simple random without replacement sampling at the first stage, and with an arbitrary sampling design for further stages. We consider coupling ...

  14. Pressurized liquid extraction-gas chromatography-mass spectrometry analysis of fragrance allergens, musks, phthalates and preservatives in baby wipes.

    Science.gov (United States)

    Celeiro, Maria; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria

    2015-03-06

    Baby wipes and wet toilet paper are specific hygiene care daily products used on newborn and children skin. These products may contain complexes mixtures of harmful chemicals. A method based on pressurized liquid extraction (PLE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed for the simultaneous determination of sixty-five chemical compounds (fragrance allergens, preservatives, musks, and phthalates) in wipes and wet toilet paper for children. These compounds are legislated in Europe according Regulation EC No 1223/2009, being twelve of them banned for their use in cosmetics, and one of them, 3-iodo-2-propynyl butylcarbamate (IPBC), is banned in products intended for children under 3 years. Also, propyl-, and butylparaben will be prohibited in leave-on cosmetic products designed for application on the nappy area of children under 3 years from April 2015. PLE is a fast, simple, easily automated technique, which permits to integrate a clean-up step during the extraction process reducing analysis time and stages. The proposed PLE-based procedure was optimized on real non-spiked baby wipe samples by means of experimental design to study the influence on extraction of parameters such as extraction solvent, temperature, extraction time, and sorbent type. Under the selected conditions, the method was validated showing satisfactory linearity, and intra-day, and inter-day precision. Recoveries were between 80-115% for most of the compounds with relative standard deviations (RSD) lower than 15%. Finally, twenty real samples were analyzed. Thirty-six of the target analytes were detected, highlighting the presence of phenoxyethanol in all analyzed samples at high concentration levels (up to 0.8%, 800μgg(-1)). Methyl paraben (MeP), and ethyl paraben (EtP) were found in 40-50% of the samples, and the recently banned isobutyl paraben (iBuP) and isopropyl paraben (iPrP), were detected in one and seven samples, respectively, at concentrations between

  15. Towards Cost-efficient Sampling Methods

    OpenAIRE

    Peng, Luo; Yongli, Li; Chong, Wu

    2014-01-01

    The sampling method has been paid much attention in the field of complex network in general and statistical physics in particular. This paper presents two new sampling methods based on the perspective that a small part of vertices with high node degree can possess the most structure information of a network. The two proposed sampling methods are efficient in sampling the nodes with high degree. The first new sampling method is improved on the basis of the stratified random sampling method and...

  16. Sample processing device and method

    DEFF Research Database (Denmark)

    2011-01-01

    A sample processing device is disclosed, which sample processing device comprises a first substrate and a second substrate, where the first substrate has a first surface comprising two area types, a first area type with a first contact angle with water and a second area type with a second contact...... angle with water, the first contact angle being smaller than the second contact angle. The first substrate defines an inlet system and a preparation system in areas of the first type which two areas are separated by a barrier system in an area of the second type. The inlet system is adapted to receive...

  17. EPA Method 8321B (SW-846): Solvent-Extractable Nonvolatile Compounds by High Performance Liquid Chromatography-Thermospray-Mass Spectrometry (HPLC-TS-MS) or Ultraviolet (UV) Detection

    Science.gov (United States)

    Method 8321B describes procedures for preparation and analysis of solid, aqueous liquid, drinking water and wipe samples using high performance liquid chromatography and mass spectrometry for extractable non-volatile compounds.

  18. Comparison of sampling methods for animal manure

    NARCIS (Netherlands)

    Derikx, P.J.L.; Ogink, N.W.M.; Hoeksma, P.

    1997-01-01

    Currently available and recently developed sampling methods for slurry and solid manure were tested for bias and reproducibility in the determination of total phosphorus and nitrogen content of samples. Sampling methods were based on techniques in which samples were taken either during loading from

  19. Standard methods for sampling and sample preparation for gamma spectroscopy

    International Nuclear Information System (INIS)

    Taskaeva, M.; Taskaev, E.; Nikolov, P.

    1993-01-01

    The strategy for sampling and sample preparation is outlined: necessary number of samples; analysis and treatment of the results received; quantity of the analysed material according to the radionuclide concentrations and analytical methods; the minimal quantity and kind of the data needed for making final conclusions and decisions on the base of the results received. This strategy was tested in gamma spectroscopic analysis of radionuclide contamination of the region of Eleshnitsa Uranium Mines. The water samples was taken and stored according to the ASTM D 3370-82. The general sampling procedures were in conformity with the recommendations of ISO 5667. The radionuclides was concentrated by coprecipitation with iron hydroxide and ion exchange. The sampling of soil samples complied with the rules of ASTM C 998, and their sample preparation - with ASTM C 999. After preparation the samples were sealed hermetically and measured. (author)

  20. Evaluation of surface sampling method performance for Bacillus Spores on clean and dirty outdoor surfaces.

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Mollye C.; Einfeld, Wayne; Boucher, Raymond M.; Brown, Gary Stephen; Tezak, Matthew Stephen

    2011-06-01

    Recovery of Bacillus atrophaeous spores from grime-treated and clean surfaces was measured in a controlled chamber study to assess sampling method performance. Outdoor surfaces investigated by wipe and vacuum sampling methods included stainless steel, glass, marble and concrete. Bacillus atrophaeous spores were used as a surrogate for Bacillus anthracis spores in this study designed to assess whether grime-coated surfaces significantly affected surface sampling method performance when compared to clean surfaces. A series of chamber tests were carried out in which known amounts of spores were allowed to gravitationally settle onto both clean and dirty surfaces. Reference coupons were co-located with test coupons in all chamber experiments to provide a quantitative measure of initial surface concentrations of spores on all surfaces, thereby allowing sampling recovery calculations. Results from these tests, carried out under both low and high humidity conditions, show that spore recovery from grime-coated surfaces is the same as or better than spore recovery from clean surfaces. Statistically significant differences between method performance for grime-coated and clean surfaces were observed in only about half of the chamber tests conducted.

  1. Wipe selection for the analysis of surface materials containing chemical warfare agent nitrogen mustard degradation products by ultra-high pressure liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Willison, Stuart A

    2012-12-28

    Degradation products arising from nitrogen mustard chemical warfare agent were deposited on common urban surfaces and determined via surface wiping, wipe extraction, and liquid chromatography–tandem mass spectrometry detection. Wipes investigated included cotton gauze, glass fiber filter, non-woven polyester fiber and filter paper, and surfaces included several porous (vinyl tile, painted drywall, wood) and mostly non-porous (laminate, galvanized steel, glass) surfaces. Wipe extracts were analyzed by ultra-high pressure liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) and compared with high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) results. An evaluation of both techniques suggests UPLC–MS/MS provides a quick and sensitive analysis of targeted degradation products in addition to being nearly four times faster than a single HPLC run, allowing for greater throughput during a wide-spread release concerning large-scale contamination and subsequent remediation events. Based on the overall performance of all tested wipes, filter paper wipes were selected over other wipes because they did not contain interferences or native species (TEA and DEA) associated with the target analytes, resulting in high percent recoveries and low background levels during sample analysis. Other wipes, including cotton gauze, would require a pre-cleaning step due to the presence of large quantities of native species or interferences of the targeted analytes. Percent recoveries obtained from a laminate surface were 47–99% for all nitrogen mustard degradation products. The resulting detection limits achieved from wipes were 0.2 ng/cm(2) for triethanolamine (TEA), 0.03 ng/cm(2) for N-ethyldiethanolamine (EDEA), 0.1 ng/cm(2) for N-methyldiethanolamine (MDEA), and 0.1 ng/cm(2) for diethanolamine (DEA).

  2. Toward cost-efficient sampling methods

    Science.gov (United States)

    Luo, Peng; Li, Yongli; Wu, Chong; Zhang, Guijie

    2015-09-01

    The sampling method has been paid much attention in the field of complex network in general and statistical physics in particular. This paper proposes two new sampling methods based on the idea that a small part of vertices with high node degree could possess the most structure information of a complex network. The two proposed sampling methods are efficient in sampling high degree nodes so that they would be useful even if the sampling rate is low, which means cost-efficient. The first new sampling method is developed on the basis of the widely used stratified random sampling (SRS) method and the second one improves the famous snowball sampling (SBS) method. In order to demonstrate the validity and accuracy of two new sampling methods, we compare them with the existing sampling methods in three commonly used simulation networks that are scale-free network, random network, small-world network, and also in two real networks. The experimental results illustrate that the two proposed sampling methods perform much better than the existing sampling methods in terms of achieving the true network structure characteristics reflected by clustering coefficient, Bonacich centrality and average path length, especially when the sampling rate is low.

  3. An improved sampling method of complex network

    Science.gov (United States)

    Gao, Qi; Ding, Xintong; Pan, Feng; Li, Weixing

    2014-12-01

    Sampling subnet is an important topic of complex network research. Sampling methods influence the structure and characteristics of subnet. Random multiple snowball with Cohen (RMSC) process sampling which combines the advantages of random sampling and snowball sampling is proposed in this paper. It has the ability to explore global information and discover the local structure at the same time. The experiments indicate that this novel sampling method could keep the similarity between sampling subnet and original network on degree distribution, connectivity rate and average shortest path. This method is applicable to the situation where the prior knowledge about degree distribution of original network is not sufficient.

  4. Broad Spectrum Sanitizing Wipes with Food Additives, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Microcide proposes to develop novel multipurpose non-toxic sanitizing wipes that are aqueous based, have shelf life of 3-5 years, have broad spectrum microbicidal...

  5. Representation of hysteresis with wipe-out memory

    International Nuclear Information System (INIS)

    Friedman, G.; Cha, K.

    2001-01-01

    A model representing scalar hysteretic systems with wipe-out memory is proposed. In this model a hysteresis operator is represented as a power series expansion containing an infinite number of terms in general. It is shown that this representation converges to any given hysteresis relation having wipe-out memory as long as the output of the given hysteresis varies sufficiently smoothly with input history. [copyright] 2001 American Institute of Physics

  6. Sampling method of environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    1984-01-01

    This manual provides sampling methods of environmental samples of airborne dust, precipitated dust, precipitated water (rain or snow), fresh water, soil, river sediment or lake sediment, discharged water from a nuclear facility, grains, tea, milk, pasture grass, limnetic organisms, daily diet, index organisms, sea water, marine sediment, marine organisms, and that for tritium and radioiodine determination for radiation monitoring from radioactive fallout or radioactivity release by nuclear facilities. This manual aims at the presentation of standard sampling procedures for environmental radioactivity monitoring regardless of monitoring objectives, and shows preservation method of environmental samples acquired at the samplingpoint for radiation counting for those except human body. Sampling techniques adopted in this manual is decided by the criteria that they are suitable for routine monitoring and any special skillfulness is not necessary. Based on the above-mentioned principle, this manual presents outline and aims of sampling, sampling position or object, sampling quantity, apparatus, equipment or vessel for sampling, sampling location, sampling procedures, pretreatment and preparation procedures of a sample for radiation counting, necessary recording items for sampling and sample transportation procedures. Special attention is described in the chapter of tritium and radioiodine because these radionuclides might be lost by the above-mentioned sample preservation method for radiation counting of less volatile radionuclides than tritium or radioiodine. (Takagi, S.)

  7. Mixed Methods Sampling: A Typology with Examples

    Science.gov (United States)

    Teddlie, Charles; Yu, Fen

    2007-01-01

    This article presents a discussion of mixed methods (MM) sampling techniques. MM sampling involves combining well-established qualitative and quantitative techniques in creative ways to answer research questions posed by MM research designs. Several issues germane to MM sampling are presented including the differences between probability and…

  8. ALARA ASSESSMENT OF SETTLER SLUDGE SAMPLING METHODS

    International Nuclear Information System (INIS)

    Nelsen, L.A.

    2009-01-01

    The purpose of this assessment is to compare underwater and above water settler sludge sampling methods to determine if the added cost for underwater sampling for the sole purpose of worker dose reductions is justified. Initial planning for sludge sampling included container, settler and knock-out-pot (KOP) sampling. Due to the significantly higher dose consequence of KOP sludge, a decision was made to sample KOP underwater to achieve worker dose reductions. Additionally, initial plans were to utilize the underwater sampling apparatus for settler sludge. Since there are no longer plans to sample KOP sludge, the decision for underwater sampling for settler sludge needs to be revisited. The present sampling plan calls for spending an estimated $2,500,000 to design and construct a new underwater sampling system (per A21 C-PL-001 RevOE). This evaluation will compare and contrast the present method of above water sampling to the underwater method that is planned by the Sludge Treatment Project (STP) and determine if settler samples can be taken using the existing sampling cart (with potentially minor modifications) while maintaining doses to workers As Low As Reasonably Achievable (ALARA) and eliminate the need for costly redesigns, testing and personnel retraining

  9. ALARA ASSESSMENT OF SETTLER SLUDGE SAMPLING METHODS

    Energy Technology Data Exchange (ETDEWEB)

    NELSEN LA

    2009-01-30

    The purpose of this assessment is to compare underwater and above water settler sludge sampling methods to determine if the added cost for underwater sampling for the sole purpose of worker dose reductions is justified. Initial planning for sludge sampling included container, settler and knock-out-pot (KOP) sampling. Due to the significantly higher dose consequence of KOP sludge, a decision was made to sample KOP underwater to achieve worker dose reductions. Additionally, initial plans were to utilize the underwater sampling apparatus for settler sludge. Since there are no longer plans to sample KOP sludge, the decision for underwater sampling for settler sludge needs to be revisited. The present sampling plan calls for spending an estimated $2,500,000 to design and construct a new underwater sampling system (per A21 C-PL-001 RevOE). This evaluation will compare and contrast the present method of above water sampling to the underwater method that is planned by the Sludge Treatment Project (STP) and determine if settler samples can be taken using the existing sampling cart (with potentially minor modifications) while maintaining doses to workers As Low As Reasonably Achievable (ALARA) and eliminate the need for costly redesigns, testing and personnel retraining.

  10. A Cultural Look at Moral Purity: Wiping the Face Clean

    Directory of Open Access Journals (Sweden)

    Spike W. S. eLee

    2015-05-01

    Full Text Available Morality is associated with bodily purity in the custom of many societies. Does that imply moral purity is a universal psychological phenomenon? Empirically, it has never been examined, as all prior experimental data came from Western samples. Theoretically, we suggest the answer is not so straightforward—it depends on the kind of universality under consideration. Combining perspectives from cultural psychology and embodiment, we predict a culture-specific form of moral purification. Specifically, given East Asians’ emphasis on the face as a representation of public self-image, we hypothesize that facial purification should have particularly potent moral effects in a face culture. Data show that face-cleaning (but not hands-cleaning reduces guilt and regret most effectively against a salient East Asian cultural background. It frees East Asians from guilt-driven prosocial behavior. In the wake of their immorality, they find a face-cleaning product especially appealing and spontaneously choose to wipe their face clean. These patterns highlight both culturally variable and universal aspects of moral purification. They further suggest an organizing principle that informs the vigorous debate between embodied and amodal perspectives.

  11. Air and Surface Sampling Method for Assessing Exposures to Quaternary Ammonium Compounds Using Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    LeBouf, Ryan F; Virji, Mohammed Abbas; Ranpara, Anand; Stefaniak, Aleksandr B

    2017-07-01

    This method was designed for sampling select quaternary ammonium (quat) compounds in air or on surfaces followed by analysis using ultraperformance liquid chromatography tandem mass spectrometry. Target quats were benzethonium chloride, didecyldimethylammonium bromide, benzyldimethyldodecylammonium chloride, benzyldimethyltetradecylammonium chloride, and benzyldimethylhexadecylammonium chloride. For air sampling, polytetrafluoroethylene (PTFE) filters are recommended for 15-min to 24-hour sampling. For surface sampling, Pro-wipe® 880 (PW) media was chosen. Samples were extracted in 60:40 acetonitrile:0.1% formic acid for 1 hour on an orbital shaker. Method detection limits range from 0.3 to 2 ng/ml depending on media and analyte. Matrix effects of media are minimized through the use of multiple reaction monitoring versus selected ion recording. Upper confidence limits on accuracy meet the National Institute for Occupational Safety and Health 25% criterion for PTFE and PW media for all analytes. Using PTFE and PW analyzed with multiple reaction monitoring, the method quantifies levels among the different quats compounds with high precision (detection limits to capture quats on air sampling filters with only a 15-min sample duration with a maximum assessed storage time of 103 days before sample extraction. This method will support future exposure assessment and quantitative epidemiologic studies to explore exposure-response relationships and establish levels of quats exposures associated with adverse health effects. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  12. Sample normalization methods in quantitative metabolomics.

    Science.gov (United States)

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Fluidics platform and method for sample preparation

    Science.gov (United States)

    Benner, Henry W.; Dzenitis, John M.

    2016-06-21

    Provided herein are fluidics platforms and related methods for performing integrated sample collection and solid-phase extraction of a target component of the sample all in one tube. The fluidics platform comprises a pump, particles for solid-phase extraction and a particle-holding means. The method comprises contacting the sample with one or more reagents in a pump, coupling a particle-holding means to the pump and expelling the waste out of the pump while the particle-holding means retains the particles inside the pump. The fluidics platform and methods herein described allow solid-phase extraction without pipetting and centrifugation.

  14. Disinfectant wipes are appropriate to control microbial bioburden from surfaces: use of a new ASTM standard test protocol to demonstrate efficacy.

    Science.gov (United States)

    Sattar, S A; Bradley, C; Kibbee, R; Wesgate, R; Wilkinson, M A C; Sharpe, T; Maillard, J-Y

    2015-12-01

    The use of disinfectant pre-soaked wipes (DPW) to decontaminate high-touch environmental surfaces (HTES) by wiping is becoming increasingly widespread in the healthcare environment. However, DPW are rarely tested using conditions simulating their field use, and the label claims of environmental surface disinfectants seldom include wiping action. To evaluate the new E2967-15 standard test specific to wipes, particularly their ability to decontaminate surfaces and to transfer acquired contamination to clean surfaces. ASTM Standard E2967-15 was used by three independent laboratories to test the efficacy of five types of commercially available wipe products. All data generated were pulled together, and reproducibility and repeatability of the standard were measured. All the commercial DPW tested achieved a >4log10 (>99.99%) reduction in colony-forming units (CFU) of Staphylococcus aureus and Acinetobacter baumanii with 10s of wiping, but only one DPW containing 0.5% accelerated H2O2 prevented the transfer of bacteria to another surface. This newly introduced standard method represents a significant advance in assessing DPW for microbial decontamination of HTES, and should greatly assist research and development, and in making more relevant and reliable claims on marketed DPW. Copyright © 2015. Published by Elsevier Ltd.

  15. Innovative methods for inorganic sample preparation

    Energy Technology Data Exchange (ETDEWEB)

    Essling, A.M.; Huff, E.A.; Graczyk, D.G.

    1992-04-01

    Procedures and guidelines are given for the dissolution of a variety of selected materials using fusion, microwave, and Parr bomb techniques. These materials include germanium glass, corium-concrete mixtures, and zeolites. Emphasis is placed on sample-preparation approaches that produce a single master solution suitable for complete multielement characterization of the sample. In addition, data are presented on the soil microwave digestion method approved by the Environmental Protection Agency (EPA). Advantages and disadvantages of each sample-preparation technique are summarized.

  16. Innovative methods for inorganic sample preparation

    International Nuclear Information System (INIS)

    Essling, A.M.; Huff, E.A.; Graczyk, D.G.

    1992-04-01

    Procedures and guidelines are given for the dissolution of a variety of selected materials using fusion, microwave, and Parr bomb techniques. These materials include germanium glass, corium-concrete mixtures, and zeolites. Emphasis is placed on sample-preparation approaches that produce a single master solution suitable for complete multielement characterization of the sample. In addition, data are presented on the soil microwave digestion method approved by the Environmental Protection Agency (EPA). Advantages and disadvantages of each sample-preparation technique are summarized

  17. New methods for sampling sparse populations

    Science.gov (United States)

    Anna Ringvall

    2007-01-01

    To improve surveys of sparse objects, methods that use auxiliary information have been suggested. Guided transect sampling uses prior information, e.g., from aerial photographs, for the layout of survey strips. Instead of being laid out straight, the strips will wind between potentially more interesting areas. 3P sampling (probability proportional to prediction) uses...

  18. Sample preparation method for scanning force microscopy

    CERN Document Server

    Jankov, I R; Szente, R N; Carreno, M N P; Swart, J W; Landers, R

    2001-01-01

    We present a method of sample preparation for studies of ion implantation on metal surfaces. The method, employing a mechanical mask, is specially adapted for samples analysed by Scanning Force Microscopy. It was successfully tested on polycrystalline copper substrates implanted with phosphorus ions at an acceleration voltage of 39 keV. The changes of the electrical properties of the surface were measured by Kelvin Probe Force Microscopy and the surface composition was analysed by Auger Electron Spectroscopy.

  19. Method and apparatus for sampling atmospheric mercury

    Science.gov (United States)

    Trujillo, Patricio E.; Campbell, Evan E.; Eutsler, Bernard C.

    1976-01-20

    A method of simultaneously sampling particulate mercury, organic mercurial vapors, and metallic mercury vapor in the working and occupational environment and determining the amount of mercury derived from each such source in the sampled air. A known volume of air is passed through a sampling tube containing a filter for particulate mercury collection, a first adsorber for the selective adsorption of organic mercurial vapors, and a second adsorber for the adsorption of metallic mercury vapor. Carbon black molecular sieves are particularly useful as the selective adsorber for organic mercurial vapors. The amount of mercury adsorbed or collected in each section of the sampling tube is readily quantitatively determined by flameless atomic absorption spectrophotometry.

  20. Subrandom methods for multidimensional nonuniform sampling.

    Science.gov (United States)

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Impact of antimicrobial wipes compared with hypochlorite solution on environmental surface contamination in a health care setting: A double-crossover study.

    Science.gov (United States)

    Siani, Harsha; Wesgate, Rebecca; Maillard, Jean-Yves

    2018-05-11

    Antimicrobial wipes are increasingly used in health care settings. This study evaluates, in a clinical setting, the efficacy of sporicidal wipes versus a cloth soaked in a 1,000 ppm chlorine solution. A double-crossover study was performed on 2 different surgical and cardiovascular wards in a 1,000-bed teaching hospital over 29 weeks. The intervention period that consisted of surface decontamination with the preimpregnated wipe or cloth soaked in chlorine followed a 5-week baseline assessment of microbial bioburden on surfaces. Environmental samples from 11 surfaces were analyzed weekly for their microbial content. A total of 1,566 environmental samples and 1,591 ATP swabs were analyzed during the trial. Overall, there were significant differences in the recovery of total aerobic bacteria (P < .001), total anaerobic bacteria (P < .001), and ATP measurement (P < .001) between wards and between the different parts of the crossover study. Generally, the use of wipes produced the largest reduction in the total aerobic and anaerobic counts when compared with the baseline data or the use of 1,000 ppm chlorine. Collectively, the introduction of training plus daily wipe disinfection significantly reduced multidrug-resistant organisms recovered from surfaces. Reversion to using 1,000 ppm chlorine resulted in the number of sites positive for multidrug-resistant organisms rising again. This double-crossover study is the first controlled field trial comparison of using preimpregnated wipes versus cotton cloth dipped into a bucket of hypochlorite to decrease surface microbial bioburden. The results demonstrate the superiority of the preimpregnated wipes in significantly decreasing microbial bioburden from high-touch surfaces. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Sampling of temporal networks: Methods and biases

    Science.gov (United States)

    Rocha, Luis E. C.; Masuda, Naoki; Holme, Petter

    2017-11-01

    Temporal networks have been increasingly used to model a diversity of systems that evolve in time; for example, human contact structures over which dynamic processes such as epidemics take place. A fundamental aspect of real-life networks is that they are sampled within temporal and spatial frames. Furthermore, one might wish to subsample networks to reduce their size for better visualization or to perform computationally intensive simulations. The sampling method may affect the network structure and thus caution is necessary to generalize results based on samples. In this paper, we study four sampling strategies applied to a variety of real-life temporal networks. We quantify the biases generated by each sampling strategy on a number of relevant statistics such as link activity, temporal paths and epidemic spread. We find that some biases are common in a variety of networks and statistics, but one strategy, uniform sampling of nodes, shows improved performance in most scenarios. Given the particularities of temporal network data and the variety of network structures, we recommend that the choice of sampling methods be problem oriented to minimize the potential biases for the specific research questions on hand. Our results help researchers to better design network data collection protocols and to understand the limitations of sampled temporal network data.

  3. Effect on skin hydration of using baby wipes to clean the napkin area of newborn babies: assessor-blinded randomised controlled equivalence trial

    Directory of Open Access Journals (Sweden)

    Lavender Tina

    2012-06-01

    Full Text Available Abstract Background Some national guidelines recommend the use of water alone for napkin cleansing. Yet, there is a readiness, amongst many parents, to use baby wipes. Evidence from randomised controlled trials, of the effect of baby wipes on newborn skin integrity is lacking. We conducted a study to examine the hypothesis that the use of a specifically formulated cleansing wipe on the napkin area of newborn infants ( Methods A prospective, assessor-blinded, randomised controlled equivalence trial was conducted during 2010. Healthy, term babies (n = 280, recruited within 48 hours of birth, were randomly assigned to have their napkin area cleansed with an alcohol-free baby wipe (140 babies or cotton wool and water (140 babies. Primary outcome was change in hydration from within 48 hours of birth to 4 weeks post-birth. Secondary outcomes comprised changes in trans-epidermal water loss, skin surface pH and erythema, presence of microbial skin contaminants/irritants at 4 weeks and napkin dermatitis reported by midwife at 4 weeks and mother during the 4 weeks. Results Complete hydration data were obtained for 254 (90.7 % babies. Wipes were shown to be equivalent to water and cotton wool in terms of skin hydration (intention-to-treat analysis: wipes 65.4 (SD 12.4 vs. water 63.5 (14.2, p = 0.47, 95 % CI -2.5 to 4.2; per protocol analysis: wipes 64.6 (12.4 vs. water 63.6 (14.3, p = 0.53, 95 % CI -2.4 to 4.2. No significant differences were found in the secondary outcomes, except for maternal-reported napkin dermatitis, which was higher in the water group (p = 0.025 for complete responses. Conclusions Baby wipes had an equivalent effect on skin hydration when compared with cotton wool and water. We found no evidence of any adverse effects of using these wipes. These findings offer reassurance to parents who choose to use baby wipes and to health professionals who support their use. Trial registration Current Controlled

  4. Chapter 12. Sampling and analytical methods

    International Nuclear Information System (INIS)

    Busenberg, E.; Plummer, L.N.; Cook, P.G.; Solomon, D.K.; Han, L.F.; Groening, M.; Oster, H.

    2006-01-01

    When water samples are taken for the analysis of CFCs, regardless of the sampling method used, contamination of samples by contact with atmospheric air (with its 'high' CFC concentrations) is a major concern. This is because groundwaters usually have lower CFC concentrations than those waters which have been exposed to the modern air. Some groundwaters might not contain CFCs and, therefore, are most sensitive to trace contamination by atmospheric air. Thus, extreme precautions are needed to obtain uncontaminated samples when groundwaters, particularly those with older ages, are sampled. It is recommended at the start of any CFC investigation that samples from a CFC-free source be collected and analysed, as a check upon the sampling equipment and methodology. The CFC-free source might be a deep monitoring well or, alternatively, CFC-free water could be carefully prepared in the laboratory. It is especially important that all tubing, pumps and connection that will be used in the sampling campaign be checked in this manner

  5. Sampling and examination methods used for TMI-2 samples

    International Nuclear Information System (INIS)

    Marley, A.W.; Akers, D.W.; McIsaac, C.V.

    1988-01-01

    The purpose of this paper is to summarize the sampling and examination techniques that were used in the collection and analysis of TMI-2 samples. Samples ranging from auxiliary building air to core debris were collected and analyzed. Handling of the larger samples and many of the smaller samples had to be done remotely and many standard laboratory analytical techniques were modified to accommodate the extremely high radiation fields associated with these samples. The TMI-2 samples presented unique problems with sampling and the laboratory analysis of prior molten fuel debris. 14 refs., 8 figs

  6. Sampling methods for terrestrial amphibians and reptiles.

    Science.gov (United States)

    Paul Stephen Corn; R. Bruce. Bury

    1990-01-01

    Methods described for sampling amphibians and reptiles in Douglas-fir forests in the Pacific Northwest include pitfall trapping, time-constrained collecting, and surveys of coarse woody debris. The herpetofauna of this region differ in breeding and nonbreeding habitats and vagility, so that no single technique is sufficient for a community study. A combination of...

  7. Passive sampling methods for contaminated sediments

    DEFF Research Database (Denmark)

    Peijnenburg, Willie J.G.M.; Teasdale, Peter R.; Reible, Danny

    2014-01-01

    “Dissolved” concentrations of contaminants in sediment porewater (Cfree) provide a more relevant exposure metric for risk assessment than do total concentrations. Passive sampling methods (PSMs) for estimating Cfree offer the potential for cost-efficient and accurate in situ characterization...

  8. Turbidity threshold sampling: Methods and instrumentation

    Science.gov (United States)

    Rand Eads; Jack Lewis

    2001-01-01

    Traditional methods for determining the frequency of suspended sediment sample collection often rely on measurements, such as water discharge, that are not well correlated to sediment concentration. Stream power is generally not a good predictor of sediment concentration for rivers that transport the bulk of their load as fines, due to the highly variable routing of...

  9. Statistical sampling method for releasing decontaminated vehicles

    International Nuclear Information System (INIS)

    Lively, J.W.; Ware, J.A.

    1996-01-01

    Earth moving vehicles (e.g., dump trucks, belly dumps) commonly haul radiologically contaminated materials from a site being remediated to a disposal site. Traditionally, each vehicle must be surveyed before being released. The logistical difficulties of implementing the traditional approach on a large scale demand that an alternative be devised. A statistical method (MIL-STD-105E, open-quotes Sampling Procedures and Tables for Inspection by Attributesclose quotes) for assessing product quality from a continuous process was adapted to the vehicle decontamination process. This method produced a sampling scheme that automatically compensates and accommodates fluctuating batch sizes and changing conditions without the need to modify or rectify the sampling scheme in the field. Vehicles are randomly selected (sampled) upon completion of the decontamination process to be surveyed for residual radioactive surface contamination. The frequency of sampling is based on the expected number of vehicles passing through the decontamination process in a given period and the confidence level desired. This process has been successfully used for 1 year at the former uranium mill site in Monticello, Utah (a CERCLA regulated clean-up site). The method forces improvement in the quality of the decontamination process and results in a lower likelihood that vehicles exceeding the surface contamination standards are offered for survey. Implementation of this statistical sampling method on Monticello Projects has resulted in more efficient processing of vehicles through decontamination and radiological release, saved hundreds of hours of processing time, provided a high level of confidence that release limits are met, and improved the radiological cleanliness of vehicles leaving the controlled site

  10. Purification of liquid products of cotton wipes biotransformation with the aid of Trichoderma viridae in orbital flight

    Science.gov (United States)

    Viacheslav, Ilyin; Korshunov, Denis

    out the fermentation in space flight. For aerobic post-treatment of substrates remaining after biodegradation of cotton wipe there was selected a strain of the fungus Trihoderma viridae, able to grow at a slightly acid environment , and to bring the pH to neutral values. Bioreactor working volume of 40 ml, where 20 ml of liquid subjected to post-treatment was placed. Strain Trihoderma viridae, isolated from ISS environment, showed steady growth in terms identical to those of pre- cultivation. Efficiency of purification was assessed using the method of gas chromatography-mass spectrometry comparing the amount and concentration of the volatile organic compounds in the samples. It turned out that the number of compounds detected in the flight sample almost halved compared to the original sample obtained after biodegradation gauze anaerobic bacteria. The total concentration of volatile impurities dropped 6 times. Thus, despite the limited resource of oxygen, due to lack of aeration in the bioreactor strain Trihoderma viridae demonstrated the ability to perform aerobic purification of substrate obtained after anaerobic biodegradation of cotton wipes under orbital flight.

  11. Remote Wiping and Secure Deletion on Mobile Devices: A Review.

    Science.gov (United States)

    Leom, Ming Di; Choo, Kim-Kwang Raymond; Hunt, Ray

    2016-11-01

    Mobile devices have become ubiquitous in almost every sector of both private and commercial endeavors. As a result of such widespread use in everyday life, many users knowingly and unknowingly save significant amounts of personal and/or commercial data on these mobile devices. Thus, loss of mobile devices through accident or theft can expose users-and their businesses-to significant personal and corporate cost. To mitigate this data leakage issue, remote wiping features have been introduced to modern mobile devices. Given the destructive nature of such a feature, however, it may be subject to criminal exploitation (e.g., a criminal exploiting one or more vulnerabilities to issue a remote wiping command to the victim's device). To obtain a better understanding of remote wiping, we survey the literature, focusing on existing approaches to secure flash storage deletion and provide a critical analysis and comparison of a variety of published research in this area. In support of our analysis, we further provide prototype experimental results for three Android devices, thus providing both a theoretical and applied focus to this article as well as providing directions for further research. © 2016 American Academy of Forensic Sciences.

  12. Effectiveness of cleaning-disinfection wipes and sprays against multidrug-resistant outbreak strains.

    Science.gov (United States)

    Kenters, Nikki; Huijskens, Elisabeth G W; de Wit, Sophie C J; van Rosmalen, Joost; Voss, Andreas

    2017-08-01

    Hospital rooms play an important role in the transmission of several health care-associated pathogens. During the last few years, a number of innovative cleaning-disinfecting products have been brought to market. In this study, commercially available products combining cleaning and disinfection were compared, using 2 different application methods. The aim was to determine which product was most effective in simultaneous cleaning and disinfection of surfaces. Seven cleaning-disinfecting wipes and sprays based on different active ingredients were tested for their efficacy in removal of microbial burden and proteins. Efficacy was tested with known Dutch outbreak strains: vancomycin-resistant enterococci (VRE), Klebsiella pneumoniae OXA-48, or Acinetobacter baumannii. For all bacteria, ready-to-use cleaning-disinfecting products reduced the microbial count with a log 10 reduction >5 with a 5-minute exposure time, with the exception of a spray based on hydrogen peroxide. Omitting the aforementioned hydrogen peroxide spray, there were no significant differences between use of a wipe or spray in bacterial load reduction. Using adenosine triphosphate (ATP) measurements, a significant difference in log 10 relative light units (RLU) reduction between various bacteria (P ≤ .001) was observed. In general, a >5 log 10 reduction of colony forming units (CFU) for tested wipes and sprays was obtained for all tested bacteria strains, with exception of hydrogen peroxide spray and VRE. Although ATP may show a difference between pre- and postcleaning, RLU reduction does not correlate with actual CFU reductions. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  13. SAMPLING IN EXTERNAL AUDIT - THE MONETARY UNIT SAMPLING METHOD

    Directory of Open Access Journals (Sweden)

    E. Dascalu

    2016-12-01

    Full Text Available This article approaches the general issue of diminishing the evidence investigation space in audit activities, by means of sampling techniques, given that in the instance of a significant data volume an exhaustive examination of the assessed popula¬tion is not possible and/or effective. The general perspective of the presentation involves dealing with sampling risk, in essence, the risk that a selected sample may not be representative for the overall population, in correlation with the audit risk model and with the component parts of this model (inherent risk, control risk and non detection risk and highlights the inter-conditionings between these two models.

  14. Different methods for volatile sampling in mammals.

    Directory of Open Access Journals (Sweden)

    Marlen Kücklich

    Full Text Available Previous studies showed that olfactory cues are important for mammalian communication. However, many specific compounds that convey information between conspecifics are still unknown. To understand mechanisms and functions of olfactory cues, olfactory signals such as volatile compounds emitted from individuals need to be assessed. Sampling of animals with and without scent glands was typically conducted using cotton swabs rubbed over the skin or fur and analysed by gas chromatography-mass spectrometry (GC-MS. However, this method has various drawbacks, including a high level of contaminations. Thus, we adapted two methods of volatile sampling from other research fields and compared them to sampling with cotton swabs. To do so we assessed the body odor of common marmosets (Callithrix jacchus using cotton swabs, thermal desorption (TD tubes and, alternatively, a mobile GC-MS device containing a thermal desorption trap. Overall, TD tubes comprised most compounds (N = 113, with half of those compounds being volatile (N = 52. The mobile GC-MS captured the fewest compounds (N = 35, of which all were volatile. Cotton swabs contained an intermediate number of compounds (N = 55, but very few volatiles (N = 10. Almost all compounds found with the mobile GC-MS were also captured with TD tubes (94%. Hence, we recommend TD tubes for state of the art sampling of body odor of mammals or other vertebrates, particularly for field studies, as they can be easily transported, stored and analysed with high performance instruments in the lab. Nevertheless, cotton swabs capture compounds which still may contribute to the body odor, e.g. after bacterial fermentation, while profiles from mobile GC-MS include only the most abundant volatiles of the body odor.

  15. Method and apparatus for continuous sampling

    International Nuclear Information System (INIS)

    Marcussen, C.

    1982-01-01

    An apparatus and method for continuously sampling a pulverous material flow includes means for extracting a representative subflow from a pulverous material flow. A screw conveyor is provided to cause the extracted subflow to be pushed upwardly through a duct to an overflow. Means for transmitting a radiation beam transversely to the subflow in the duct, and means for sensing the transmitted beam through opposite pairs of windows in the duct are provided to measure the concentration of one or more constituents in the subflow. (author)

  16. Comparisons of methods for generating conditional Poisson samples and Sampford samples

    OpenAIRE

    Grafström, Anton

    2005-01-01

    Methods for conditional Poisson sampling (CP-sampling) and Sampford sampling are compared and the focus is on the efficiency of the methods. The efficiency is investigated by simulation in different sampling situations. It was of interest to compare methods since new methods for both CP-sampling and Sampford sampling were introduced by Bondesson, Traat & Lundqvist in 2004. The new methods are acceptance rejection methods that use the efficient Pareto sampling method. They are found to be ...

  17. A Bayesian Method for Weighted Sampling

    OpenAIRE

    Lo, Albert Y.

    1993-01-01

    Bayesian statistical inference for sampling from weighted distribution models is studied. Small-sample Bayesian bootstrap clone (BBC) approximations to the posterior distribution are discussed. A second-order property for the BBC in unweighted i.i.d. sampling is given. A consequence is that BBC approximations to a posterior distribution of the mean and to the sampling distribution of the sample average, can be made asymptotically accurate by a proper choice of the random variables that genera...

  18. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Representative Sampling Methods I...—Representative Sampling Methods The methods and equipment used for sampling waste materials will vary with the form and consistency of the waste materials to be sampled. Samples collected using the sampling...

  19. Log sampling methods and software for stand and landscape analyses.

    Science.gov (United States)

    Lisa J. Bate; Torolf R. Torgersen; Michael J. Wisdom; Edward O. Garton; Shawn C. Clabough

    2008-01-01

    We describe methods for efficient, accurate sampling of logs at landscape and stand scales to estimate density, total length, cover, volume, and weight. Our methods focus on optimizing the sampling effort by choosing an appropriate sampling method and transect length for specific forest conditions and objectives. Sampling methods include the line-intersect method and...

  20. Identifying trace evidence in data wiping application software

    Directory of Open Access Journals (Sweden)

    Gregory H. Carlton

    2012-06-01

    Full Text Available One area of particular concern for computer forensics examiners involves situations in which someone utilized software applications to destroy evidence. There are products available in the marketplace that are relatively inexpensive and advertised as being able to destroy targeted portions of data stored within a computer system. This study was undertaken to identify these tools and analyze them to determine the extent to which each of the evaluated data wiping applications perform their tasks and to identify trace evidence, if any, left behind on disk media after executing these applications. We evaluated five Windows 7 compatible software products whose advertised features include the ability for users to wipe targeted files, folders, or evidence of selected activities. We conducted a series of experiments that involved executing each application on systems with identical data, and we then analyzed the results and compared the before and after images for each application. We identified information for each application that is beneficial to forensics examiners when faced with similar situations. This paper describes our application selection process, our application evaluation methodology, and our findings. Following this, we describe limitations of this study and suggest areas of additional research that will benefit the study of digital forensics.

  1. Statistical sampling methods for soils monitoring

    Science.gov (United States)

    Ann M. Abbott

    2010-01-01

    Development of the best sampling design to answer a research question should be an interactive venture between the land manager or researcher and statisticians, and is the result of answering various questions. A series of questions that can be asked to guide the researcher in making decisions that will arrive at an effective sampling plan are described, and a case...

  2. Evaluation of Sampling Methods for Bacillus Spore ...

    Science.gov (United States)

    Journal Article Following a wide area release of biological materials, mapping the extent of contamination is essential for orderly response and decontamination operations. HVAC filters process large volumes of air and therefore collect highly representative particulate samples in buildings. HVAC filter extraction may have great utility in rapidly estimating the extent of building contamination following a large-scale incident. However, until now, no studies have been conducted comparing the two most appropriate sampling approaches for HVAC filter materials: direct extraction and vacuum-based sampling.

  3. Wipe-rinse technique for quantitating microbial contamination on large surfaces

    Science.gov (United States)

    Kirschner, L. E.; Puleo, J. R.

    1979-01-01

    The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling area sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 sq m (8.0 sq ft).

  4. Small-sample-worth perturbation methods

    International Nuclear Information System (INIS)

    1985-01-01

    It has been assumed that the perturbed region, R/sub p/, is large enough so that: (1) even without a great deal of biasing there is a substantial probability that an average source-neutron will enter it; and (2) once having entered, the neutron is likely to make several collisions in R/sub p/ during its lifetime. Unfortunately neither assumption is valid for the typical configurations one encounters in small-sample-worth experiments. In such experiments one measures the reactivity change which is induced when a very small void in a critical assembly is filled with a sample of some test-material. Only a minute fraction of the fission-source neutrons ever gets into the sample and, of those neutrons that do, most emerge uncollided. Monte Carlo small-sample perturbations computations are described

  5. 19 CFR 151.70 - Method of sampling by Customs.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling by Customs. 151.70 Section 151... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70 Method of sampling by Customs. A general sample shall be taken from each sampling unit, unless it is not...

  6. Perpendicular distance sampling: an alternative method for sampling downed coarse woody debris

    Science.gov (United States)

    Michael S. Williams; Jeffrey H. Gove

    2003-01-01

    Coarse woody debris (CWD) plays an important role in many forest ecosystem processes. In recent years, a number of new methods have been proposed to sample CWD. These methods select individual logs into the sample using some form of unequal probability sampling. One concern with most of these methods is the difficulty in estimating the volume of each log. A new method...

  7. On Angular Sampling Methods for 3-D Spatial Channel Models

    DEFF Research Database (Denmark)

    Fan, Wei; Jämsä, Tommi; Nielsen, Jesper Ødum

    2015-01-01

    This paper discusses generating three dimensional (3D) spatial channel models with emphasis on the angular sampling methods. Three angular sampling methods, i.e. modified uniform power sampling, modified uniform angular sampling, and random pairing methods are proposed and investigated in detail....... The random pairing method, which uses only twenty sinusoids in the ray-based model for generating the channels, presents good results if the spatial channel cluster is with a small elevation angle spread. For spatial clusters with large elevation angle spreads, however, the random pairing method would fail...... and the other two methods should be considered....

  8. Sampling Methods for Wallenius' and Fisher's Noncentral Hypergeometric Distributions

    DEFF Research Database (Denmark)

    Fog, Agner

    2008-01-01

    the mode, ratio-of-uniforms rejection method, and rejection by sampling in the tau domain. Methods for the multivariate distributions include: simulation of urn experiments, conditional method, Gibbs sampling, and Metropolis-Hastings sampling. These methods are useful for Monte Carlo simulation of models...... of biased sampling and models of evolution and for calculating moments and quantiles of the distributions.......Several methods for generating variates with univariate and multivariate Wallenius' and Fisher's noncentral hypergeometric distributions are developed. Methods for the univariate distributions include: simulation of urn experiments, inversion by binary search, inversion by chop-down search from...

  9. Some connections between importance sampling and enhanced sampling methods in molecular dynamics.

    Science.gov (United States)

    Lie, H C; Quer, J

    2017-11-21

    In molecular dynamics, enhanced sampling methods enable the collection of better statistics of rare events from a reference or target distribution. We show that a large class of these methods is based on the idea of importance sampling from mathematical statistics. We illustrate this connection by comparing the Hartmann-Schütte method for rare event simulation (J. Stat. Mech. Theor. Exp. 2012, P11004) and the Valsson-Parrinello method of variationally enhanced sampling [Phys. Rev. Lett. 113, 090601 (2014)]. We use this connection in order to discuss how recent results from the Monte Carlo methods literature can guide the development of enhanced sampling methods.

  10. Sampling Methods in Cardiovascular Nursing Research: An Overview.

    Science.gov (United States)

    Kandola, Damanpreet; Banner, Davina; O'Keefe-McCarthy, Sheila; Jassal, Debbie

    2014-01-01

    Cardiovascular nursing research covers a wide array of topics from health services to psychosocial patient experiences. The selection of specific participant samples is an important part of the research design and process. The sampling strategy employed is of utmost importance to ensure that a representative sample of participants is chosen. There are two main categories of sampling methods: probability and non-probability. Probability sampling is the random selection of elements from the population, where each element of the population has an equal and independent chance of being included in the sample. There are five main types of probability sampling including simple random sampling, systematic sampling, stratified sampling, cluster sampling, and multi-stage sampling. Non-probability sampling methods are those in which elements are chosen through non-random methods for inclusion into the research study and include convenience sampling, purposive sampling, and snowball sampling. Each approach offers distinct advantages and disadvantages and must be considered critically. In this research column, we provide an introduction to these key sampling techniques and draw on examples from the cardiovascular research. Understanding the differences in sampling techniques may aid nurses in effective appraisal of research literature and provide a reference pointfor nurses who engage in cardiovascular research.

  11. 19 CFR 151.83 - Method of sampling.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling. For...

  12. 7 CFR 29.110 - Method of sampling.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling tobacco...

  13. Final Rule: 2013 Conditional Exclusions From Solid Waste and Hazardous Waste for Solvent-Contaminated Wipes

    Science.gov (United States)

    This is a regulation page for the final rule EPA issued on July 31, 2013 that modifies the hazardous waste management regulations for solvent-contaminated wipes under the Resource Conservation and Recovery Act (RCRA).

  14. Validation of EIA sampling methods - bacterial and biochemical analysis

    Digital Repository Service at National Institute of Oceanography (India)

    Sheelu, G.; LokaBharathi, P.A.; Nair, S.; Raghukumar, C.; Mohandass, C.

    to temporal factors. Paired T-test between pre- and post-disturbance samples suggested that the above methods of sampling and variables like TC, protein and TOC could be used for monitoring disturbance....

  15. New adaptive sampling method in particle image velocimetry

    International Nuclear Information System (INIS)

    Yu, Kaikai; Xu, Jinglei; Tang, Lan; Mo, Jianwei

    2015-01-01

    This study proposes a new adaptive method to enable the number of interrogation windows and their positions in a particle image velocimetry (PIV) image interrogation algorithm to become self-adapted according to the seeding density. The proposed method can relax the constraint of uniform sampling rate and uniform window size commonly adopted in the traditional PIV algorithm. In addition, the positions of the sampling points are redistributed on the basis of the spring force generated by the sampling points. The advantages include control of the number of interrogation windows according to the local seeding density and smoother distribution of sampling points. The reliability of the adaptive sampling method is illustrated by processing synthetic and experimental images. The synthetic example attests to the advantages of the sampling method. Compared with that of the uniform interrogation technique in the experimental application, the spatial resolution is locally enhanced when using the proposed sampling method. (technical design note)

  16. A flexible method for multi-level sample size determination

    International Nuclear Information System (INIS)

    Lu, Ming-Shih; Sanborn, J.B.; Teichmann, T.

    1997-01-01

    This paper gives a flexible method to determine sample sizes for both systematic and random error models (this pertains to sampling problems in nuclear safeguard questions). In addition, the method allows different attribute rejection limits. The new method could assist achieving a higher detection probability and enhance inspection effectiveness

  17. Wet Wipe Allergens: Retrospective Analysis From the North American Contact Dermatitis Group 2011-2014.

    Science.gov (United States)

    Warshaw, Erin M; Aschenbeck, Kelly A; Zug, Kathryn A; Belsito, Donald V; Zirwas, Matthew J; Fowler, Joseph F; Taylor, James S; Sasseville, Denis; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Maibach, Howard I; Mathias, C G Toby; DeKoven, Joel G

    Although there are several case reports of wet wipe-associated contact dermatitis, the prevalence of wipes as a source of allergic contact dermatitis in larger populations and the responsible allergens are largely unknown. The aim of the study was to determine the prevalence of wet wipes as a source of contact allergy and the most commonly associated allergens in a North American tertiary referral patch test population. Data collected from 2011 to 2014 by the North American Contact Dermatitis Group was used to conduct a retrospective cross-sectional analysis of patient demographics and patch test results associated with the triple-digit source code for "wet wipe." Of the 9037 patients patch tested during the study period, 79 (0.9%) had a positive patch test reaction to an allergen identified with a wet wipe source. The most commonly associated allergens were preservatives, including the following: methylisothiazolinone (MI) (59.0%), methylchloroisothiazolinone (MCI)/MI (35.6%), bronopol (2-bromo-2-nitropropane-1,3-diol) (27.4%), and iodopropynyl butylcarbamate (12.3%). Fragrance (combined) represented 12.3%. Anal/genital dermatitis was 15 times more likely (P contact allergy had their contact allergens detected by the North American Contact Dermatitis Group screening series. Wet wipes are an important source of contact allergy. Preservatives are the main allergens, especially isothiazolinones.

  18. Experimental skin deposition of chromium on the hands following handling of samples of leather and metal

    DEFF Research Database (Denmark)

    Bregnbak, David; Thyssen, Jacob P.; Jellesen, Morten Stendahl

    2016-01-01

    Background: Chromium is an important skin sensitizer. Exposure to it has been regulated in cement, and recently in leather. Studies on the deposition of chromium ions on the skin as a result of handling different chromium-containing materials are sparse, but could improve the risk assessment...... of contact sensitization and allergic contact dermatitis caused by chromium. Objectives: To determine whether the handling of chromium-containing samples of leather and metal results in the deposition of chromium onto the skin. Methods: Five healthy volunteers participated. For 30 min, they handled samples...... of leather and metal known to contain and release chromium. Skin deposition of chromium was assessed with the acid wipe sampling technique. Results: Acid wipe sampling of the participants' fingers showed chromium deposition on the skin in all participants who had been exposed to leather (range 0.01–0.20 µg...

  19. Systems and methods for self-synchronized digital sampling

    Science.gov (United States)

    Samson, Jr., John R. (Inventor)

    2008-01-01

    Systems and methods for self-synchronized data sampling are provided. In one embodiment, a system for capturing synchronous data samples is provided. The system includes an analog to digital converter adapted to capture signals from one or more sensors and convert the signals into a stream of digital data samples at a sampling frequency determined by a sampling control signal; and a synchronizer coupled to the analog to digital converter and adapted to receive a rotational frequency signal from a rotating machine, wherein the synchronizer is further adapted to generate the sampling control signal, and wherein the sampling control signal is based on the rotational frequency signal.

  20. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1993-03-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others

  1. DOE methods for evaluating environmental and waste management samples.

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S C; McCulloch, M; Thomas, B L; Riley, R G; Sklarew, D S; Mong, G M; Fadeff, S K [eds.; Pacific Northwest Lab., Richland, WA (United States)

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others.

  2. Detection of Nonvolatile Inorganic Oxidizer-Based Explosives from Wipe Collections by Infrared Thermal Desorption-Direct Analysis in Real Time Mass Spectrometry.

    Science.gov (United States)

    Forbes, Thomas P; Sisco, Edward; Staymates, Matthew

    2018-05-07

    Infrared thermal desorption (IRTD) was coupled with direct analysis in real time mass spectrometry (DART-MS) for the detection of both inorganic and organic explosives from wipe collected samples. This platform generated discrete and rapid heating rates that allowed volatile and semivolatile organic explosives to thermally desorb at relatively lower temperatures, while still achieving elevated temperatures required to desorb nonvolatile inorganic oxidizer-based explosives. IRTD-DART-MS demonstrated the thermal desorption and detection of refractory potassium chlorate and potassium perchlorate oxidizers, compounds difficult to desorb with traditional moderate-temperature resistance-based thermal desorbers. Nanogram to sub-nanogram sensitivities were established for analysis of a range of organic and inorganic oxidizer-based explosive compounds, with further enhancement limited by the thermal properties of the most common commercial wipe materials. Detailed investigations and high-speed visualization revealed conduction from the heated glass-mica base plate as the dominant process for heating of the wipe and analyte materials, resulting in thermal desorption through boiling, aerosolization, and vaporization of samples. The thermal desorption and ionization characteristics of the IRTD-DART technique resulted in optimal sensitivity for the formation of nitrate adducts with both organic and inorganic species. The IRTD-DART-MS coupling and IRTD in general offer promising explosive detection capabilities to the defense, security, and law enforcement arenas.

  3. Sampling methods for amphibians in streams in the Pacific Northwest.

    Science.gov (United States)

    R. Bruce Bury; Paul Stephen. Corn

    1991-01-01

    Methods describing how to sample aquatic and semiaquatic amphibians in small streams and headwater habitats in the Pacific Northwest are presented. We developed a technique that samples 10-meter stretches of selected streams, which was adequate to detect presence or absence of amphibian species and provided sample sizes statistically sufficient to compare abundance of...

  4. A random spatial sampling method in a rural developing nation

    Science.gov (United States)

    Michelle C. Kondo; Kent D.W. Bream; Frances K. Barg; Charles C. Branas

    2014-01-01

    Nonrandom sampling of populations in developing nations has limitations and can inaccurately estimate health phenomena, especially among hard-to-reach populations such as rural residents. However, random sampling of rural populations in developing nations can be challenged by incomplete enumeration of the base population. We describe a stratified random sampling method...

  5. Multielement methods of atomic fluorescence analysis of enviromental samples

    International Nuclear Information System (INIS)

    Rigin, V.I.

    1985-01-01

    A multielement method of atomic fluorescence analysis of environmental samples based on sample decomposition by autoclave fluorination and gas-phase atomization of volatile compounds in inductive araon plasma using a nondispersive polychromator is suggested. Detection limits of some elements (Be, Sr, Cd, V, Mo, Te, Ru etc.) for different sample forms introduced in to an analyzer are given

  6. Sampling bee communities using pan traps: alternative methods increase sample size

    Science.gov (United States)

    Monitoring of the status of bee populations and inventories of bee faunas require systematic sampling. Efficiency and ease of implementation has encouraged the use of pan traps to sample bees. Efforts to find an optimal standardized sampling method for pan traps have focused on pan trap color. Th...

  7. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    Science.gov (United States)

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  8. THE USE OF RANKING SAMPLING METHOD WITHIN MARKETING RESEARCH

    Directory of Open Access Journals (Sweden)

    CODRUŢA DURA

    2011-01-01

    Full Text Available Marketing and statistical literature available to practitioners provides a wide range of sampling methods that can be implemented in the context of marketing research. Ranking sampling method is based on taking apart the general population into several strata, namely into several subdivisions which are relatively homogenous regarding a certain characteristic. In fact, the sample will be composed by selecting, from each stratum, a certain number of components (which can be proportional or non-proportional to the size of the stratum until the pre-established volume of the sample is reached. Using ranking sampling within marketing research requires the determination of some relevant statistical indicators - average, dispersion, sampling error etc. To that end, the paper contains a case study which illustrates the actual approach used in order to apply the ranking sample method within a marketing research made by a company which provides Internet connection services, on a particular category of customers – small and medium enterprises.

  9. An efficient method for sampling the essential subspace of proteins

    NARCIS (Netherlands)

    Amadei, A; Linssen, A.B M; de Groot, B.L.; van Aalten, D.M.F.; Berendsen, H.J.C.

    A method is presented for a more efficient sampling of the configurational space of proteins as compared to conventional sampling techniques such as molecular dynamics. The method is based on the large conformational changes in proteins revealed by the ''essential dynamics'' analysis. A form of

  10. Neonatal blood gas sampling methods | Goenka | South African ...

    African Journals Online (AJOL)

    There is little published guidance that systematically evaluates the different methods of neonatal blood gas sampling, where each method has its individual benefits and risks. This review critically surveys the available evidence to generate a comparison between arterial and capillary blood gas sampling, focusing on their ...

  11. A Mixed Methods Sampling Methodology for a Multisite Case Study

    Science.gov (United States)

    Sharp, Julia L.; Mobley, Catherine; Hammond, Cathy; Withington, Cairen; Drew, Sam; Stringfield, Sam; Stipanovic, Natalie

    2012-01-01

    The flexibility of mixed methods research strategies makes such approaches especially suitable for multisite case studies. Yet the utilization of mixed methods to select sites for these studies is rarely reported. The authors describe their pragmatic mixed methods approach to select a sample for their multisite mixed methods case study of a…

  12. Present status of NMCC and sample preparation method for bio-samples

    International Nuclear Information System (INIS)

    Futatsugawa, S.; Hatakeyama, S.; Saitou, S.; Sera, K.

    1993-01-01

    In NMCC(Nishina Memorial Cyclotron Center) we are doing researches on PET of nuclear medicine (Positron Emission Computed Tomography) and PIXE analysis (Particle Induced X-ray Emission) using a small cyclotron of compactly designed. The NMCC facilities have been opened to researchers of other institutions since April 1993. The present status of NMCC is described. Bio-samples (medical samples, plants, animals and environmental samples) have mainly been analyzed by PIXE in NMCC. Small amounts of bio-samples for PIXE are decomposed quickly and easily in a sealed PTFE (polytetrafluoroethylene) vessel with a microwave oven. This sample preparation method of bio-samples also is described. (author)

  13. Evaluation of common methods for sampling invertebrate pollinator assemblages: net sampling out-perform pan traps.

    Directory of Open Access Journals (Sweden)

    Tony J Popic

    Full Text Available Methods for sampling ecological assemblages strive to be efficient, repeatable, and representative. Unknowingly, common methods may be limited in terms of revealing species function and so of less value for comparative studies. The global decline in pollination services has stimulated surveys of flower-visiting invertebrates, using pan traps and net sampling. We explore the relative merits of these two methods in terms of species discovery, quantifying abundance, function, and composition, and responses of species to changing floral resources. Using a spatially-nested design we sampled across a 5000 km(2 area of arid grasslands, including 432 hours of net sampling and 1296 pan trap-days, between June 2010 and July 2011. Net sampling yielded 22% more species and 30% higher abundance than pan traps, and better reflected the spatio-temporal variation of floral resources. Species composition differed significantly between methods; from 436 total species, 25% were sampled by both methods, 50% only by nets, and the remaining 25% only by pans. Apart from being less comprehensive, if pan traps do not sample flower-visitors, the link to pollination is questionable. By contrast, net sampling functionally linked species to pollination through behavioural observations of flower-visitation interaction frequency. Netted specimens are also necessary for evidence of pollen transport. Benefits of net-based sampling outweighed minor differences in overall sampling effort. As pan traps and net sampling methods are not equivalent for sampling invertebrate-flower interactions, we recommend net sampling of invertebrate pollinator assemblages, especially if datasets are intended to document declines in pollination and guide measures to retain this important ecosystem service.

  14. Evaluation of common methods for sampling invertebrate pollinator assemblages: net sampling out-perform pan traps.

    Science.gov (United States)

    Popic, Tony J; Davila, Yvonne C; Wardle, Glenda M

    2013-01-01

    Methods for sampling ecological assemblages strive to be efficient, repeatable, and representative. Unknowingly, common methods may be limited in terms of revealing species function and so of less value for comparative studies. The global decline in pollination services has stimulated surveys of flower-visiting invertebrates, using pan traps and net sampling. We explore the relative merits of these two methods in terms of species discovery, quantifying abundance, function, and composition, and responses of species to changing floral resources. Using a spatially-nested design we sampled across a 5000 km(2) area of arid grasslands, including 432 hours of net sampling and 1296 pan trap-days, between June 2010 and July 2011. Net sampling yielded 22% more species and 30% higher abundance than pan traps, and better reflected the spatio-temporal variation of floral resources. Species composition differed significantly between methods; from 436 total species, 25% were sampled by both methods, 50% only by nets, and the remaining 25% only by pans. Apart from being less comprehensive, if pan traps do not sample flower-visitors, the link to pollination is questionable. By contrast, net sampling functionally linked species to pollination through behavioural observations of flower-visitation interaction frequency. Netted specimens are also necessary for evidence of pollen transport. Benefits of net-based sampling outweighed minor differences in overall sampling effort. As pan traps and net sampling methods are not equivalent for sampling invertebrate-flower interactions, we recommend net sampling of invertebrate pollinator assemblages, especially if datasets are intended to document declines in pollination and guide measures to retain this important ecosystem service.

  15. Multi-frequency direct sampling method in inverse scattering problem

    Science.gov (United States)

    Kang, Sangwoo; Lambert, Marc; Park, Won-Kwang

    2017-10-01

    We consider the direct sampling method (DSM) for the two-dimensional inverse scattering problem. Although DSM is fast, stable, and effective, some phenomena remain unexplained by the existing results. We show that the imaging function of the direct sampling method can be expressed by a Bessel function of order zero. We also clarify the previously unexplained imaging phenomena and suggest multi-frequency DSM to overcome traditional DSM. Our method is evaluated in simulation studies using both single and multiple frequencies.

  16. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Laboratory Management Division of the DOE. Methods are prepared for entry into DOE Methods as chapter editors, together with DOE and other participants in this program, identify analytical and sampling method needs. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types. open-quotes Draftclose quotes or open-quotes Verified.close quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations

  17. Interval sampling methods and measurement error: a computer simulation.

    Science.gov (United States)

    Wirth, Oliver; Slaven, James; Taylor, Matthew A

    2014-01-01

    A simulation study was conducted to provide a more thorough account of measurement error associated with interval sampling methods. A computer program simulated the application of momentary time sampling, partial-interval recording, and whole-interval recording methods on target events randomly distributed across an observation period. The simulation yielded measures of error for multiple combinations of observation period, interval duration, event duration, and cumulative event duration. The simulations were conducted up to 100 times to yield measures of error variability. Although the present simulation confirmed some previously reported characteristics of interval sampling methods, it also revealed many new findings that pertain to each method's inherent strengths and weaknesses. The analysis and resulting error tables can help guide the selection of the most appropriate sampling method for observation-based behavioral assessments. © Society for the Experimental Analysis of Behavior.

  18. Direct sampling methods for inverse elastic scattering problems

    Science.gov (United States)

    Ji, Xia; Liu, Xiaodong; Xi, Yingxia

    2018-03-01

    We consider the inverse elastic scattering of incident plane compressional and shear waves from the knowledge of the far field patterns. Specifically, three direct sampling methods for location and shape reconstruction are proposed using the different component of the far field patterns. Only inner products are involved in the computation, thus the novel sampling methods are very simple and fast to be implemented. With the help of the factorization of the far field operator, we give a lower bound of the proposed indicator functionals for sampling points inside the scatterers. While for the sampling points outside the scatterers, we show that the indicator functionals decay like the Bessel functions as the sampling point goes away from the boundary of the scatterers. We also show that the proposed indicator functionals continuously dependent on the far field patterns, which further implies that the novel sampling methods are extremely stable with respect to data error. For the case when the observation directions are restricted into the limited aperture, we firstly introduce some data retrieval techniques to obtain those data that can not be measured directly and then use the proposed direct sampling methods for location and shape reconstructions. Finally, some numerical simulations in two dimensions are conducted with noisy data, and the results further verify the effectiveness and robustness of the proposed sampling methods, even for multiple multiscale cases and limited-aperture problems.

  19. Sampling and analysis methods for geothermal fluids and gases

    Energy Technology Data Exchange (ETDEWEB)

    Watson, J.C.

    1978-07-01

    The sampling procedures for geothermal fluids and gases include: sampling hot springs, fumaroles, etc.; sampling condensed brine and entrained gases; sampling steam-lines; low pressure separator systems; high pressure separator systems; two-phase sampling; downhole samplers; and miscellaneous methods. The recommended analytical methods compiled here cover physical properties, dissolved solids, and dissolved and entrained gases. The sequences of methods listed for each parameter are: wet chemical, gravimetric, colorimetric, electrode, atomic absorption, flame emission, x-ray fluorescence, inductively coupled plasma-atomic emission spectroscopy, ion exchange chromatography, spark source mass spectrometry, neutron activation analysis, and emission spectrometry. Material on correction of brine component concentrations for steam loss during flashing is presented. (MHR)

  20. Field Sample Preparation Method Development for Isotope Ratio Mass Spectrometry

    International Nuclear Information System (INIS)

    Leibman, C.; Weisbrod, K.; Yoshida, T.

    2015-01-01

    Non-proliferation and International Security (NA-241) established a working group of researchers from Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) to evaluate the utilization of in-field mass spectrometry for safeguards applications. The survey of commercial off-the-shelf (COTS) mass spectrometers (MS) revealed no instrumentation existed capable of meeting all the potential safeguards requirements for performance, portability, and ease of use. Additionally, fieldable instruments are unlikely to meet the International Target Values (ITVs) for accuracy and precision for isotope ratio measurements achieved with laboratory methods. The major gaps identified for in-field actinide isotope ratio analysis were in the areas of: 1. sample preparation and/or sample introduction, 2. size reduction of mass analyzers and ionization sources, 3. system automation, and 4. decreased system cost. Development work in 2 through 4, numerated above continues, in the private and public sector. LANL is focusing on developing sample preparation/sample introduction methods for use with the different sample types anticipated for safeguard applications. Addressing sample handling and sample preparation methods for MS analysis will enable use of new MS instrumentation as it becomes commercially available. As one example, we have developed a rapid, sample preparation method for dissolution of uranium and plutonium oxides using ammonium bifluoride (ABF). ABF is a significantly safer and faster alternative to digestion with boiling combinations of highly concentrated mineral acids. Actinides digested with ABF yield fluorides, which can then be analyzed directly or chemically converted and separated using established column chromatography techniques as needed prior to isotope analysis. The reagent volumes and the sample processing steps associated with ABF sample digestion lend themselves to automation and field

  1. A direct sampling method to an inverse medium scattering problem

    KAUST Repository

    Ito, Kazufumi; Jin, Bangti; Zou, Jun

    2012-01-01

    In this work we present a novel sampling method for time harmonic inverse medium scattering problems. It provides a simple tool to directly estimate the shape of the unknown scatterers (inhomogeneous media), and it is applicable even when

  2. A direct sampling method for inverse electromagnetic medium scattering

    KAUST Repository

    Ito, Kazufumi; Jin, Bangti; Zou, Jun

    2013-01-01

    In this paper, we study the inverse electromagnetic medium scattering problem of estimating the support and shape of medium scatterers from scattered electric/magnetic near-field data. We shall develop a novel direct sampling method based

  3. Evaluation of the point-centred-quarter method of sampling ...

    African Journals Online (AJOL)

    -quarter method.The parameter which was most efficiently sampled was species composition relativedensity) with 90% replicate similarity being achieved with 100 point-centred-quarters. However, this technique cannot be recommended, even ...

  4. Field evaluation of personal sampling methods for multiple bioaerosols.

    Science.gov (United States)

    Wang, Chi-Hsun; Chen, Bean T; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine

    2015-01-01

    Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.

  5. Adaptive cluster sampling: An efficient method for assessing inconspicuous species

    Science.gov (United States)

    Andrea M. Silletti; Joan Walker

    2003-01-01

    Restorationistis typically evaluate the success of a project by estimating the population sizes of species that have been planted or seeded. Because total census is raely feasible, they must rely on sampling methods for population estimates. However, traditional random sampling designs may be inefficient for species that, for one reason or another, are challenging to...

  6. Field evaluation of personal sampling methods for multiple bioaerosols.

    Directory of Open Access Journals (Sweden)

    Chi-Hsun Wang

    Full Text Available Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min. Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.

  7. Global metabolite analysis of yeast: evaluation of sample preparation methods

    DEFF Research Database (Denmark)

    Villas-Bôas, Silas Granato; Højer-Pedersen, Jesper; Åkesson, Mats Fredrik

    2005-01-01

    Sample preparation is considered one of the limiting steps in microbial metabolome analysis. Eukaryotes and prokaryotes behave very differently during the several steps of classical sample preparation methods for analysis of metabolites. Even within the eukaryote kingdom there is a vast diversity...

  8. A distance limited method for sampling downed coarse woody debris

    Science.gov (United States)

    Jeffrey H. Gove; Mark J. Ducey; Harry T. Valentine; Michael S. Williams

    2012-01-01

    A new sampling method for down coarse woody debris is proposed based on limiting the perpendicular distance from individual pieces to a randomly chosen sample point. Two approaches are presented that allow different protocols to be used to determine field measurements; estimators for each protocol are also developed. Both protocols are compared via simulation against...

  9. A comprehensive comparison of perpendicular distance sampling methods for sampling downed coarse woody debris

    Science.gov (United States)

    Jeffrey H. Gove; Mark J. Ducey; Harry T. Valentine; Michael S. Williams

    2013-01-01

    Many new methods for sampling down coarse woody debris have been proposed in the last dozen or so years. One of the most promising in terms of field application, perpendicular distance sampling (PDS), has several variants that have been progressively introduced in the literature. In this study, we provide an overview of the different PDS variants and comprehensive...

  10. Approximation of the exponential integral (well function) using sampling methods

    Science.gov (United States)

    Baalousha, Husam Musa

    2015-04-01

    Exponential integral (also known as well function) is often used in hydrogeology to solve Theis and Hantush equations. Many methods have been developed to approximate the exponential integral. Most of these methods are based on numerical approximations and are valid for a certain range of the argument value. This paper presents a new approach to approximate the exponential integral. The new approach is based on sampling methods. Three different sampling methods; Latin Hypercube Sampling (LHS), Orthogonal Array (OA), and Orthogonal Array-based Latin Hypercube (OA-LH) have been used to approximate the function. Different argument values, covering a wide range, have been used. The results of sampling methods were compared with results obtained by Mathematica software, which was used as a benchmark. All three sampling methods converge to the result obtained by Mathematica, at different rates. It was found that the orthogonal array (OA) method has the fastest convergence rate compared with LHS and OA-LH. The root mean square error RMSE of OA was in the order of 1E-08. This method can be used with any argument value, and can be used to solve other integrals in hydrogeology such as the leaky aquifer integral.

  11. Neutron activation analysis of certified samples by the absolute method

    Science.gov (United States)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  12. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, open-quotes Draftclose quotes or open-quotes Verifiedclose quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy

  13. DOE methods for evaluating environmental and waste management samples

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K. [eds.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, {open_quotes}Draft{close_quotes} or {open_quotes}Verified{close_quotes}. {open_quotes}Draft{close_quotes} methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. {open_quotes}Verified{close_quotes} methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy.

  14. On-capillary sample cleanup method for the electrophoretic determination of carbohydrates in juice samples.

    Science.gov (United States)

    Morales-Cid, Gabriel; Simonet, Bartolomé M; Cárdenas, Soledad; Valcárcel, Miguel

    2007-05-01

    On many occasions, sample treatment is a critical step in electrophoretic analysis. As an alternative to batch procedures, in this work, a new strategy is presented with a view to develop an on-capillary sample cleanup method. This strategy is based on the partial filling of the capillary with carboxylated single-walled carbon nanotube (c-SWNT). The nanoparticles retain interferences from the matrix allowing the determination and quantification of carbohydrates (viz glucose, maltose and fructose). The precision of the method for the analysis of real samples ranged from 5.3 to 6.4%. The proposed method was compared with a method based on a batch filtration of the juice sample through diatomaceous earth and further electrophoretic determination. This method was also validated in this work. The RSD for this other method ranged from 5.1 to 6%. The results obtained by both methods were statistically comparable demonstrating the accuracy of the proposed methods and their effectiveness. Electrophoretic separation of carbohydrates was achieved using 200 mM borate solution as a buffer at pH 9.5 and applying 15 kV. During separation, the capillary temperature was kept constant at 40 degrees C. For the on-capillary cleanup method, a solution containing 50 mg/L of c-SWNTs prepared in 300 mM borate solution at pH 9.5 was introduced for 60 s into the capillary just before sample introduction. For the electrophoretic analysis of samples cleaned in batch with diatomaceous earth, it is also recommended to introduce into the capillary, just before the sample, a 300 mM borate solution as it enhances the sensitivity and electrophoretic resolution.

  15. Validation of method in instrumental NAA for food products sample

    International Nuclear Information System (INIS)

    Alfian; Siti Suprapti; Setyo Purwanto

    2010-01-01

    NAA is a method of testing that has not been standardized. To affirm and confirm that this method is valid. it must be done validation of the method with various sample standard reference materials. In this work. the validation is carried for food product samples using NIST SRM 1567a (wheat flour) and NIST SRM 1568a (rice flour). The results show that the validation method for testing nine elements (Al, K, Mg, Mn, Na, Ca, Fe, Se and Zn) in SRM 1567a and eight elements (Al, K, Mg, Mn, Na, Ca, Se and Zn ) in SRM 1568a pass the test of accuracy and precision. It can be conclude that this method has power to give valid result in determination element of the food products samples. (author)

  16. Extending the alias Monte Carlo sampling method to general distributions

    International Nuclear Information System (INIS)

    Edwards, A.L.; Rathkopf, J.A.; Smidt, R.K.

    1991-01-01

    The alias method is a Monte Carlo sampling technique that offers significant advantages over more traditional methods. It equals the accuracy of table lookup and the speed of equal probable bins. The original formulation of this method sampled from discrete distributions and was easily extended to histogram distributions. We have extended the method further to applications more germane to Monte Carlo particle transport codes: continuous distributions. This paper presents the alias method as originally derived and our extensions to simple continuous distributions represented by piecewise linear functions. We also present a method to interpolate accurately between distributions tabulated at points other than the point of interest. We present timing studies that demonstrate the method's increased efficiency over table lookup and show further speedup achieved through vectorization. 6 refs., 12 figs., 2 tabs

  17. Soil separator and sampler and method of sampling

    Science.gov (United States)

    O'Brien, Barry H [Idaho Falls, ID; Ritter, Paul D [Idaho Falls, ID

    2010-02-16

    A soil sampler includes a fluidized bed for receiving a soil sample. The fluidized bed may be in communication with a vacuum for drawing air through the fluidized bed and suspending particulate matter of the soil sample in the air. In a method of sampling, the air may be drawn across a filter, separating the particulate matter. Optionally, a baffle or a cyclone may be included within the fluidized bed for disentrainment, or dedusting, so only the finest particulate matter, including asbestos, will be trapped on the filter. The filter may be removable, and may be tested to determine the content of asbestos and other hazardous particulate matter in the soil sample.

  18. Methods of human body odor sampling: the effect of freezing.

    Science.gov (United States)

    Lenochova, Pavlina; Roberts, S Craig; Havlicek, Jan

    2009-02-01

    Body odor sampling is an essential tool in human chemical ecology research. However, methodologies of individual studies vary widely in terms of sampling material, length of sampling, and sample processing. Although these differences might have a critical impact on results obtained, almost no studies test validity of current methods. Here, we focused on the effect of freezing samples between collection and use in experiments involving body odor perception. In 2 experiments, we tested whether axillary odors were perceived differently by raters when presented fresh or having been frozen and whether several freeze-thaw cycles affected sample quality. In the first experiment, samples were frozen for 2 weeks, 1 month, or 4 months. We found no differences in ratings of pleasantness, attractiveness, or masculinity between fresh and frozen samples. Similarly, almost no differences between repeatedly thawed and fresh samples were found. We found some variations in intensity; however, this was unrelated to length of storage. The second experiment tested differences between fresh samples and those frozen for 6 months. Again no differences in subjective ratings were observed. These results suggest that freezing has no significant effect on perceived odor hedonicity and that samples can be reliably used after storage for relatively long periods.

  19. Probability Sampling Method for a Hidden Population Using Respondent-Driven Sampling: Simulation for Cancer Survivors.

    Science.gov (United States)

    Jung, Minsoo

    2015-01-01

    When there is no sampling frame within a certain group or the group is concerned that making its population public would bring social stigma, we say the population is hidden. It is difficult to approach this kind of population survey-methodologically because the response rate is low and its members are not quite honest with their responses when probability sampling is used. The only alternative known to address the problems caused by previous methods such as snowball sampling is respondent-driven sampling (RDS), which was developed by Heckathorn and his colleagues. RDS is based on a Markov chain, and uses the social network information of the respondent. This characteristic allows for probability sampling when we survey a hidden population. We verified through computer simulation whether RDS can be used on a hidden population of cancer survivors. According to the simulation results of this thesis, the chain-referral sampling of RDS tends to minimize as the sample gets bigger, and it becomes stabilized as the wave progresses. Therefore, it shows that the final sample information can be completely independent from the initial seeds if a certain level of sample size is secured even if the initial seeds were selected through convenient sampling. Thus, RDS can be considered as an alternative which can improve upon both key informant sampling and ethnographic surveys, and it needs to be utilized for various cases domestically as well.

  20. Efficiency of snake sampling methods in the Brazilian semiarid region.

    Science.gov (United States)

    Mesquita, Paula C M D; Passos, Daniel C; Cechin, Sonia Z

    2013-09-01

    The choice of sampling methods is a crucial step in every field survey in herpetology. In countries where time and financial support are limited, the choice of the methods is critical. The methods used to sample snakes often lack objective criteria, and the traditional methods have apparently been more important when making the choice. Consequently researches using not-standardized methods are frequently found in the literature. We have compared four commonly used methods for sampling snake assemblages in a semiarid area in Brazil. We compared the efficacy of each method based on the cost-benefit regarding the number of individuals and species captured, time, and financial investment. We found that pitfall traps were the less effective method in all aspects that were evaluated and it was not complementary to the other methods in terms of abundance of species and assemblage structure. We conclude that methods can only be considered complementary if they are standardized to the objectives of the study. The use of pitfall traps in short-term surveys of the snake fauna in areas with shrubby vegetation and stony soil is not recommended.

  1. Standard methods for sampling North American freshwater fishes

    Science.gov (United States)

    Bonar, Scott A.; Hubert, Wayne A.; Willis, David W.

    2009-01-01

    This important reference book provides standard sampling methods recommended by the American Fisheries Society for assessing and monitoring freshwater fish populations in North America. Methods apply to ponds, reservoirs, natural lakes, and streams and rivers containing cold and warmwater fishes. Range-wide and eco-regional averages for indices of abundance, population structure, and condition for individual species are supplied to facilitate comparisons of standard data among populations. Provides information on converting nonstandard to standard data, statistical and database procedures for analyzing and storing standard data, and methods to prevent transfer of invasive species while sampling.

  2. A multi-dimensional sampling method for locating small scatterers

    International Nuclear Information System (INIS)

    Song, Rencheng; Zhong, Yu; Chen, Xudong

    2012-01-01

    A multiple signal classification (MUSIC)-like multi-dimensional sampling method (MDSM) is introduced to locate small three-dimensional scatterers using electromagnetic waves. The indicator is built with the most stable part of signal subspace of the multi-static response matrix on a set of combinatorial sampling nodes inside the domain of interest. It has two main advantages compared to the conventional MUSIC methods. First, the MDSM is more robust against noise. Second, it can work with a single incidence even for multi-scatterers. Numerical simulations are presented to show the good performance of the proposed method. (paper)

  3. Advanced Markov chain Monte Carlo methods learning from past samples

    CERN Document Server

    Liang, Faming; Carrol, Raymond J

    2010-01-01

    This book provides comprehensive coverage of simulation of complex systems using Monte Carlo methods. Developing algorithms that are immune to the local trap problem has long been considered as the most important topic in MCMC research. Various advanced MCMC algorithms which address this problem have been developed include, the modified Gibbs sampler, the methods based on auxiliary variables and the methods making use of past samples. The focus of this book is on the algorithms that make use of past samples. This book includes the multicanonical algorithm, dynamic weighting, dynamically weight

  4. Comparison of Two Surface Contamination Sampling Techniques Conducted for the Characterization of Two Pajarito Site Manhattan Project National Historic Park Properties

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Tammy Ann [Montana Tech of the Univ. of Montana, Butte, MT (United States); Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-29

    Technical Area-18 (TA-18), also known as Pajarito Site, is located on Los Alamos National Laboratory property and has historic buildings that will be included in the Manhattan Project National Historic Park. Characterization studies of metal contamination were needed in two of the four buildings that are on the historic registry in this area, a “battleship” bunker building (TA-18-0002) and the Pond cabin (TA-18-0029). However, these two buildings have been exposed to the elements, are decades old, and have porous and rough surfaces (wood and concrete). Due to these conditions, it was questioned whether standard wipe sampling would be adequate to detect surface dust metal contamination in these buildings. Thus, micro-vacuum and surface wet wipe sampling techniques were performed side-by-side at both buildings and results were compared statistically. A two-tail paired t-test revealed that the micro-vacuum and wet wipe techniques were statistically different for both buildings. Further mathematical analysis revealed that the wet wipe technique picked up more metals from the surface than the microvacuum technique. Wet wipes revealed concentrations of beryllium and lead above internal housekeeping limits; however, using an yttrium normalization method with linear regression analysis between beryllium and yttrium revealed a correlation indicating that the beryllium levels were likely due to background and not operational contamination. PPE and administrative controls were implemented for National Park Service (NPS) and Department of Energy (DOE) tours as a result of this study. Overall, this study indicates that the micro-vacuum technique may not be an efficient technique to sample for metal dust contamination.

  5. Wipes coated with a singlet-oxygen-producing photosensitizer are effective against human influenza virus but not against norovirus

    NARCIS (Netherlands)

    Verhaelen, Katharina; Bouwknegt, Martijn; Rutjes, Saskia; de Roda Husman, Ana Maria; Duizer, Erwin

    2014-01-01

    Transmission of enteric and respiratory viruses, including human norovirus (hNoV) and human influenza virus, may involve surfaces. In food preparation and health care settings, surfaces are cleaned with wipes; however, wiping may not efficiently reduce contamination or may even spread viruses,

  6. Development of sample preparation method for honey analysis using PIXE

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Chiba, Keiko; Sera, Koichiro

    2008-01-01

    We developed an original preparation method for honey samples (samples in paste-like state) specifically designed for PIXE analysis. The results of PIXE analysis of thin targets prepared by adding a standard containing nine elements to honey samples demonstrated that the preparation method bestowed sufficient accuracy on quantitative values. PIXE analysis of 13 kinds of honey was performed, and eight mineral components (Si, P, S, K, Ca, Mn, Cu and Zn) were detected in all honey samples. The principal mineral components were K and Ca, and the quantitative value for K accounted for the majority of the total value for mineral components. K content in honey varies greatly depending on the plant source. Chestnuts had the highest K content. In fact, it was 2-3 times that of Manuka, which is known as a high quality honey. K content of false-acacia, which is produced in the greatest abundance, was 1/20 that of chestnuts. (author)

  7. Validation of single-sample doubly labeled water method

    International Nuclear Information System (INIS)

    Webster, M.D.; Weathers, W.W.

    1989-01-01

    We have experimentally validated a single-sample variant of the doubly labeled water method for measuring metabolic rate and water turnover in a very small passerine bird, the verdin (Auriparus flaviceps). We measured CO 2 production using the Haldane gravimetric technique and compared these values with estimates derived from isotopic data. Doubly labeled water results based on the one-sample calculations differed from Haldane values by less than 0.5% on average (range -8.3 to 11.2%, n = 9). Water flux computed by the single-sample method differed by -1.5% on average from results for the same birds based on the standard, two-sample technique (range -13.7 to 2.0%, n = 9)

  8. Examination of Hydrate Formation Methods: Trying to Create Representative Samples

    Energy Technology Data Exchange (ETDEWEB)

    Kneafsey, T.J.; Rees, E.V.L.; Nakagawa, S.; Kwon, T.-H.

    2011-04-01

    Forming representative gas hydrate-bearing laboratory samples is important so that the properties of these materials may be measured, while controlling the composition and other variables. Natural samples are rare, and have often experienced pressure and temperature changes that may affect the property to be measured [Waite et al., 2008]. Forming methane hydrate samples in the laboratory has been done a number of ways, each having advantages and disadvantages. The ice-to-hydrate method [Stern et al., 1996], contacts melting ice with methane at the appropriate pressure to form hydrate. The hydrate can then be crushed and mixed with mineral grains under controlled conditions, and then compacted to create laboratory samples of methane hydrate in a mineral medium. The hydrate in these samples will be part of the load-bearing frame of the medium. In the excess gas method [Handa and Stupin, 1992], water is distributed throughout a mineral medium (e.g. packed moist sand, drained sand, moistened silica gel, other porous media) and the mixture is brought to hydrate-stable conditions (chilled and pressurized with gas), allowing hydrate to form. This method typically produces grain-cementing hydrate from pendular water in sand [Waite et al., 2004]. In the dissolved gas method [Tohidi et al., 2002], water with sufficient dissolved guest molecules is brought to hydrate-stable conditions where hydrate forms. In the laboratory, this is can be done by pre-dissolving the gas of interest in water and then introducing it to the sample under the appropriate conditions. With this method, it is easier to form hydrate from more soluble gases such as carbon dioxide. It is thought that this method more closely simulates the way most natural gas hydrate has formed. Laboratory implementation, however, is difficult, and sample formation is prohibitively time consuming [Minagawa et al., 2005; Spangenberg and Kulenkampff, 2005]. In another version of this technique, a specified quantity of gas

  9. Standard methods for sampling freshwater fishes: opportunities for international collaboration

    OpenAIRE

    Bonar, Scott A.; Mercado-Silva, Norman; Hubert, Wayne A.; Beard, T. Douglas; Dave, Göran; Kubečka, Jan; Graeb, Brian D.S.; Lester, Nigel P.; Porath, Mark; Winfield, Ian J.

    2017-01-01

    With publication of Standard Methods for Sampling North American Freshwater Fishes in 2009, the American Fisheries Society (AFS) recommended standard procedures for North America. To explore interest in standardizing at intercontinental scales, a symposium attended by international specialists in freshwater fish sampling was convened at the 145th Annual AFS Meeting in Portland, Oregon, in August 2015. Participants represented all continents except Australia and Antarctica and were employed by...

  10. Characterizing lentic freshwater fish assemblages using multiple sampling methods

    Science.gov (United States)

    Fischer, Jesse R.; Quist, Michael C.

    2014-01-01

    Characterizing fish assemblages in lentic ecosystems is difficult, and multiple sampling methods are almost always necessary to gain reliable estimates of indices such as species richness. However, most research focused on lentic fish sampling methodology has targeted recreationally important species, and little to no information is available regarding the influence of multiple methods and timing (i.e., temporal variation) on characterizing entire fish assemblages. Therefore, six lakes and impoundments (48–1,557 ha surface area) were sampled seasonally with seven gear types to evaluate the combined influence of sampling methods and timing on the number of species and individuals sampled. Probabilities of detection for species indicated strong selectivities and seasonal trends that provide guidance on optimal seasons to use gears when targeting multiple species. The evaluation of species richness and number of individuals sampled using multiple gear combinations demonstrated that appreciable benefits over relatively few gears (e.g., to four) used in optimal seasons were not present. Specifically, over 90 % of the species encountered with all gear types and season combinations (N = 19) from six lakes and reservoirs were sampled with nighttime boat electrofishing in the fall and benthic trawling, modified-fyke, and mini-fyke netting during the summer. Our results indicated that the characterization of lentic fish assemblages was highly influenced by the selection of sampling gears and seasons, but did not appear to be influenced by waterbody type (i.e., natural lake, impoundment). The standardization of data collected with multiple methods and seasons to account for bias is imperative to monitoring of lentic ecosystems and will provide researchers with increased reliability in their interpretations and decisions made using information on lentic fish assemblages.

  11. Fluidics platform and method for sample preparation and analysis

    Science.gov (United States)

    Benner, W. Henry; Dzenitis, John M.; Bennet, William J.; Baker, Brian R.

    2014-08-19

    Herein provided are fluidics platform and method for sample preparation and analysis. The fluidics platform is capable of analyzing DNA from blood samples using amplification assays such as polymerase-chain-reaction assays and loop-mediated-isothermal-amplification assays. The fluidics platform can also be used for other types of assays and analyzes. In some embodiments, a sample in a sealed tube can be inserted directly. The following isolation, detection, and analyzes can be performed without a user's intervention. The disclosed platform may also comprises a sample preparation system with a magnetic actuator, a heater, and an air-drying mechanism, and fluid manipulation processes for extraction, washing, elution, assay assembly, assay detection, and cleaning after reactions and between samples.

  12. Adaptive sampling method in deep-penetration particle transport problem

    International Nuclear Information System (INIS)

    Wang Ruihong; Ji Zhicheng; Pei Lucheng

    2012-01-01

    Deep-penetration problem has been one of the difficult problems in shielding calculation with Monte Carlo method for several decades. In this paper, a kind of particle transport random walking system under the emission point as a sampling station is built. Then, an adaptive sampling scheme is derived for better solution with the achieved information. The main advantage of the adaptive scheme is to choose the most suitable sampling number from the emission point station to obtain the minimum value of the total cost in the process of the random walk. Further, the related importance sampling method is introduced. Its main principle is to define the importance function due to the particle state and to ensure the sampling number of the emission particle is proportional to the importance function. The numerical results show that the adaptive scheme under the emission point as a station could overcome the difficulty of underestimation of the result in some degree, and the adaptive importance sampling method gets satisfied results as well. (authors)

  13. Methods for Sampling and Measurement of Compressed Air Contaminants

    International Nuclear Information System (INIS)

    Stroem, L.

    1976-10-01

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  14. Methods for Sampling and Measurement of Compressed Air Contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Stroem, L

    1976-10-15

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  15. Sampling and sample preparation methods for the analysis of trace elements in biological material

    International Nuclear Information System (INIS)

    Sansoni, B.; Iyengar, V.

    1978-05-01

    The authors attempt to give a most systamtic possible treatment of the sample taking and sample preparation of biological material (particularly in human medicine) for trace analysis (e.g. neutron activation analysis, atomic absorption spectrometry). Contamination and loss problems are discussed as well as the manifold problems of the different consistency of solid and liquid biological materials, as well as the stabilization of the sample material. The process of dry and wet ashing is particularly dealt with, where new methods are also described. (RB) [de

  16. An algorithm to improve sampling efficiency for uncertainty propagation using sampling based method

    International Nuclear Information System (INIS)

    Campolina, Daniel; Lima, Paulo Rubens I.; Pereira, Claubia; Veloso, Maria Auxiliadora F.

    2015-01-01

    Sample size and computational uncertainty were varied in order to investigate sample efficiency and convergence of the sampling based method for uncertainty propagation. Transport code MCNPX was used to simulate a LWR model and allow the mapping, from uncertain inputs of the benchmark experiment, to uncertain outputs. Random sampling efficiency was improved through the use of an algorithm for selecting distributions. Mean range, standard deviation range and skewness were verified in order to obtain a better representation of uncertainty figures. Standard deviation of 5 pcm in the propagated uncertainties for 10 n-samples replicates was adopted as convergence criterion to the method. Estimation of 75 pcm uncertainty on reactor k eff was accomplished by using sample of size 93 and computational uncertainty of 28 pcm to propagate 1σ uncertainty of burnable poison radius. For a fixed computational time, in order to reduce the variance of the uncertainty propagated, it was found, for the example under investigation, it is preferable double the sample size than double the amount of particles followed by Monte Carlo process in MCNPX code. (author)

  17. Evaluation of Stress Loaded Steel Samples Using Selected Electromagnetic Methods

    International Nuclear Information System (INIS)

    Chady, T.

    2004-01-01

    In this paper the magnetic leakage flux and eddy current method were used to evaluate changes of materials' properties caused by stress. Seven samples made of ferromagnetic material with different level of applied stress were prepared. First, the leakage magnetic fields were measured by scanning the surface of the specimens with GMR gradiometer. Next, the same samples were evaluated using an eddy current sensor. A comparison between results obtained from both methods was carried out. Finally, selected parameters of the measured signal were calculated and utilized to evaluate level of the applied stress. A strong coincidence between amount of the applied stress and the maximum amplitude of the derivative was confirmed

  18. On the Exploitation of Sensitivity Derivatives for Improving Sampling Methods

    Science.gov (United States)

    Cao, Yanzhao; Hussaini, M. Yousuff; Zang, Thomas A.

    2003-01-01

    Many application codes, such as finite-element structural analyses and computational fluid dynamics codes, are capable of producing many sensitivity derivatives at a small fraction of the cost of the underlying analysis. This paper describes a simple variance reduction method that exploits such inexpensive sensitivity derivatives to increase the accuracy of sampling methods. Three examples, including a finite-element structural analysis of an aircraft wing, are provided that illustrate an order of magnitude improvement in accuracy for both Monte Carlo and stratified sampling schemes.

  19. [Progress in sample preparation and analytical methods for trace polar small molecules in complex samples].

    Science.gov (United States)

    Zhang, Qianchun; Luo, Xialin; Li, Gongke; Xiao, Xiaohua

    2015-09-01

    Small polar molecules such as nucleosides, amines, amino acids are important analytes in biological, food, environmental, and other fields. It is necessary to develop efficient sample preparation and sensitive analytical methods for rapid analysis of these polar small molecules in complex matrices. Some typical materials in sample preparation, including silica, polymer, carbon, boric acid and so on, are introduced in this paper. Meanwhile, the applications and developments of analytical methods of polar small molecules, such as reversed-phase liquid chromatography, hydrophilic interaction chromatography, etc., are also reviewed.

  20. Estimation of creatinine in Urine sample by Jaffe's method

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Arunkumar, Suja; Sawant, Pramilla D.; Rao, B.B.

    2012-01-01

    In-vitro bioassay monitoring is based on the determination of activity concentrations in biological samples excreted from the body and is most suitable for alpha and beta emitters. A truly representative bioassay sample is the one having all the voids collected during a 24-h period however, this being technically difficult, overnight urine samples collected by the workers are analyzed. These overnight urine samples are collected for 10-16 h, however in the absence of any specific information, 12 h duration is assumed and the observed results are then corrected accordingly obtain the daily excretion rate. To reduce the uncertainty due to unknown duration of sample collection, IAEA has recommended two methods viz., measurement of specific gravity and creatinine excretion rate in urine sample. Creatinine is a final metabolic product creatinine phosphate in the body and is excreted at a steady rate for people with normally functioning kidneys. It is, therefore, often used as a normalization factor for estimation of duration of sample collection. The present study reports the chemical procedure standardized and its application for the estimation of creatinine in urine samples collected from occupational workers. Chemical procedure for estimation of creatinine in bioassay samples was standardized and applied successfully for its estimation in bioassay samples collected from the workers. The creatinine excretion rate observed for these workers is lower than observed in literature. Further, work is in progress to generate a data bank of creatinine excretion rate for most of the workers and also to study the variability in creatinine coefficient for the same individual based on the analysis of samples collected for different duration

  1. Sampling methods for low-frequency electromagnetic imaging

    International Nuclear Information System (INIS)

    Gebauer, Bastian; Hanke, Martin; Schneider, Christoph

    2008-01-01

    For the detection of hidden objects by low-frequency electromagnetic imaging the linear sampling method works remarkably well despite the fact that the rigorous mathematical justification is still incomplete. In this work, we give an explanation for this good performance by showing that in the low-frequency limit the measurement operator fulfils the assumptions for the fully justified variant of the linear sampling method, the so-called factorization method. We also show how the method has to be modified in the physically relevant case of electromagnetic imaging with divergence-free currents. We present numerical results to illustrate our findings, and to show that similar performance can be expected for the case of conducting objects and layered backgrounds

  2. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    Science.gov (United States)

    Schindler, Matthias; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-01

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO2 and reduced to graphite to determine 14C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  3. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, Matthias, E-mail: matthias.schindler@physik.uni-erlangen.de; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-15

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO{sub 2} and reduced to graphite to determine {sup 14}C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  4. Hand hygiene with soap and water is superior to alcohol rub and antiseptic wipes for removal of Clostridium difficile.

    Science.gov (United States)

    Oughton, Matthew T; Loo, Vivian G; Dendukuri, Nandini; Fenn, Susan; Libman, Michael D

    2009-10-01

    To evaluate common hand hygiene methods for efficacy in removing Clostridium difficile. Randomized crossover comparison among 10 volunteers with hands experimentally contaminated by nontoxigenic C. difficile. Interventions included warm water with plain soap, cold water with plain soap, warm water with antibacterial soap, antiseptic hand wipes, alcohol-based handrub, and a control involving no intervention. All interventions were evaluated for mean reduction in colony-forming units (CFUs) under 2 contamination protocols: "whole hand" and "palmar surface." Results were analyzed according to a Bayesian approach, by using hierarchical models adjusted for multiple observations. Under the whole-hand protocol, the greatest adjusted mean reductions were achieved by warm water with plain soap (2.14 log(10) CFU/mL [95% credible interval (CrI), 1.74-2.54 log(10) CFU/mL]), cold water with plain soap (1.88 log(10) CFU/mL [95% CrI, 1.48-2.28 log(10) CFU/mL), and warm water with antibacterial soap (1.51 log(10) CFU/mL [95% CrI, 1.12-1.91 log(10) CFU/mL]), followed by antiseptic hand wipes (0.57 log(10) CFU/mL [95% CrI, 0.17-0.96 log(10) CFU/mL]). Alcohol-based handrub (0.06 log(10) CFU/mL [95% CrI, -0.34 to 0.45 log(10) CFU/mL]) was equivalent to no intervention. Under the palmar surface protocol, warm water with plain soap, cold water with plain soap, and warm water with antibacterial soap again yielded the greatest mean reductions, followed by antiseptic hand wipes (26.6, 26.6, 26.6, and 21.9 CFUs per plate, respectively), when compared with alcohol-based handrub. Hypothenar (odds ratio, 10.98 [95% CrI, 1.96-37.65]) and thenar (odds ratio, 6.99 [95% CrI, 1.25-23.41]) surfaces were more likely than fingertips to remain heavily contaminated after handwashing. Handwashing with soap and water showed the greatest efficacy in removing C. difficile and should be performed preferentially over the use of alcohol-based handrubs when contact with C. difficile is suspected or likely.

  5. Wiping Out Disadvantages: The Programs and Services Needed To Supplement Regular Education for Poor School Children.

    Science.gov (United States)

    Education Law Center, Inc., Newark, NJ.

    In "Abbott v. Burke" the New Jersey Supreme Court determined that the state constitutional guarantee to a thorough and efficient education must include a supplemental program designed to wipe out the deficits poor children bring with them to school. In this report, the Education Law Center draws on educational research to identify the…

  6. Patient and environmental service employee satisfaction of using germicidal bleach wipes for patient room cleaning.

    Science.gov (United States)

    Aronhalt, Kimberly C; McManus, James; Orenstein, Robert; Faller, Rebecca; Link, Mary

    2013-01-01

    More healthcare institutions are using bleach products which are sporicidal to reduce Clostridium difficile infection (CDI). There may be patient and employee concerns about the appearance of bleach residue left on surfaces, odors, and respiratory tract irritation. The intervention used bleach wipes for daily and terminal patient room cleaning to reduce transmission of CDI and was implemented on patient care units with a relatively high incidence of CDI. Both patients and Environmental Services (ES) staff were surveyed to assess their satisfaction of the bleach wipe product used during room cleaning. Patients (n = 94) (91%) continued to be very satisfied with how well their rooms were cleaned every day. Bleach wipes were well tolerated by patients (n = 44) (100%) surveyed on the medical units and less tolerated by patients (n = 50) (22%) on the hematology-oncology units. ES staff (6) reported less satisfaction and more respiratory irritation from using the bleach wipes; however, later their satisfaction improved. © 2012 National Association for Healthcare Quality.

  7. 78 FR 46447 - Conditional Exclusions From Solid Waste and Hazardous Waste for Solvent-Contaminated Wipes

    Science.gov (United States)

    2013-07-31

    ... section 307 of the Clean Water Act (CWA)); A municipal solid waste landfill that is regulated under 40 CFR... laundries and dry cleaners could dispose of sludge from cleaning solvent-contaminated wipes in solid waste landfills if the sludge does not exhibit a hazardous waste characteristic. \\8\\ The Agency stated in the...

  8. Putting evaporators to work: wiped film evaporator for high level wastes

    International Nuclear Information System (INIS)

    Dierks, R.D.; Bonner, W.F.

    1976-01-01

    At Battelle, Pacific Northwest Laboratories, a pilot scale, wiped film evaporator was tested for concentrating high level liquid wastes from Purex-type nuclear fuel recovery processes. The concentrates produced up to 60 wt-percent total solids; and the simplicity of operation and design of the evaporator gave promise for low maintenance and high reliability

  9. Methods for Characterisation of unknown Suspect Radioactive Samples

    International Nuclear Information System (INIS)

    Sahagia, M.; Grigorescu, E.L.; Luca, A.; Razdolescu, A.C.; Ivan, C.

    2001-01-01

    Full text: The paper presents various identification and measurement methods, used for the expertise of a wide variety of suspect radioactive materials, whose circulation was not legally stated. The main types of examined samples were: radioactive sources, illegally trafficked; suspect radioactive materials or radioactively contaminated devices; uranium tablets; fire detectors containing 241 Am sources; osmium samples containing radioactive 185 Os or enriched 187 Os. The types of analyses and determination methods were as follows: the chemical composition was determined by using identification reagents or by neutron activation analysis; the radionuclide composition was determined by using gamma-ray spectrometry; the activity and particle emission rates were determined by using calibrated radiometric equipment; the absorbed dose rate at the wall of all types of containers and samples was determined by using calibrated dose ratemeters. The radiation exposure risk for population, due to these radioactive materials, was evaluated for every case. (author)

  10. Sampling and analysis methods for geothermal fluids and gases

    Energy Technology Data Exchange (ETDEWEB)

    Shannon, D. W.

    1978-01-01

    The data obtained for the first round robin sample collected at Mesa 6-2 wellhead, East Mesa Test Site, Imperial Valley are summarized. Test results are listed by method used for cross reference to the analytic methods section. Results obtained for radioactive isotopes present in the brine sample are tabulated. The data obtained for the second round robin sample collected from the Woolsey No. 1 first stage flash unit, San Diego Gas and Electric Niland Test Facility are presented in the same manner. Lists of the participants of the two round robins are given. Data from miscellaneous analyses are included. Summaries of values derived from the round robin raw data are presented. (MHR)

  11. Microbial diversity in fecal samples depends on DNA extraction method

    DEFF Research Database (Denmark)

    Mirsepasi, Hengameh; Persson, Søren; Struve, Carsten

    2014-01-01

    was to evaluate two different DNA extraction methods in order to choose the most efficient method for studying intestinal bacterial diversity using Denaturing Gradient Gel Electrophoresis (DGGE). FINDINGS: In this study, a semi-automatic DNA extraction system (easyMag®, BioMérieux, Marcy I'Etoile, France......BACKGROUND: There are challenges, when extracting bacterial DNA from specimens for molecular diagnostics, since fecal samples also contain DNA from human cells and many different substances derived from food, cell residues and medication that can inhibit downstream PCR. The purpose of the study...... by easyMag® from the same fecal samples. Furthermore, DNA extracts obtained using easyMag® seemed to contain inhibitory compounds, since in order to perform a successful PCR-analysis, the sample should be diluted at least 10 times. DGGE performed on PCR from DNA extracted by QIAamp DNA Stool Mini Kit DNA...

  12. A Frequency Domain Design Method For Sampled-Data Compensators

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Jannerup, Ole Erik

    1990-01-01

    A new approach to the design of a sampled-data compensator in the frequency domain is investigated. The starting point is a continuous-time compensator for the continuous-time system which satisfy specific design criteria. The new design method will graphically show how the discrete...

  13. Phosphorus analysis in milk samples by neutron activation analysis method

    International Nuclear Information System (INIS)

    Oliveira, R.M. de; Cunha, I.I.L.

    1991-01-01

    The determination of phosphorus in milk samples by instrumental thermal neutron activation analysis is described. The procedure involves a short irradiation in a nuclear reactor and measurement of the beta radiation emitted by phosphorus - 32 after a suitable decay period. The sources of error were studied and the established method was applied to standard reference materials of known phosphorus content. (author)

  14. Sampling point selection for energy estimation in the quasicontinuum method

    NARCIS (Netherlands)

    Beex, L.A.A.; Peerlings, R.H.J.; Geers, M.G.D.

    2010-01-01

    The quasicontinuum (QC) method reduces computational costs of atomistic calculations by using interpolation between a small number of so-called repatoms to represent the displacements of the complete lattice and by selecting a small number of sampling atoms to estimate the total potential energy of

  15. A General Linear Method for Equating with Small Samples

    Science.gov (United States)

    Albano, Anthony D.

    2015-01-01

    Research on equating with small samples has shown that methods with stronger assumptions and fewer statistical estimates can lead to decreased error in the estimated equating function. This article introduces a new approach to linear observed-score equating, one which provides flexible control over how form difficulty is assumed versus estimated…

  16. Performance of sampling methods to estimate log characteristics for wildlife.

    Science.gov (United States)

    Lisa J. Bate; Torolf R. Torgersen; Michael J. Wisdom; Edward O. Garton

    2004-01-01

    Accurate estimation of the characteristics of log resources, or coarse woody debris (CWD), is critical to effective management of wildlife and other forest resources. Despite the importance of logs as wildlife habitat, methods for sampling logs have traditionally focused on silvicultural and fire applications. These applications have emphasized estimates of log volume...

  17. Effect of method of sample preparation on ruminal in situ ...

    African Journals Online (AJOL)

    Midmar) was harvested at three and four weeks after cutting and fertilizing with 200 kg nitrogen (N)/ha. Freshly cut herbage was used to investigate the following four sample preparation methods. In trial 1, herbage was (1) chopped with a paper-cutting guillotine into 5-10 mm lengths, representing fresh (FR) herbage; ...

  18. Sample processing method for the determination of perchlorate in milk

    International Nuclear Information System (INIS)

    Dyke, Jason V.; Kirk, Andrea B.; Kalyani Martinelango, P.; Dasgupta, Purnendu K.

    2006-01-01

    In recent years, many different water sources and foods have been reported to contain perchlorate. Studies indicate that significant levels of perchlorate are present in both human and dairy milk. The determination of perchlorate in milk is particularly important due to its potential health impact on infants and children. As for many other biological samples, sample preparation is more time consuming than the analysis itself. The concurrent presence of large amounts of fats, proteins, carbohydrates, etc., demands some initial cleanup; otherwise the separation column lifetime and the limit of detection are both greatly compromised. Reported milk processing methods require the addition of chemicals such as ethanol, acetic acid or acetonitrile. Reagent addition is undesirable in trace analysis. We report here an essentially reagent-free sample preparation method for the determination of perchlorate in milk. Milk samples are spiked with isotopically labeled perchlorate and centrifuged to remove lipids. The resulting liquid is placed in a disposable centrifugal ultrafilter device with a molecular weight cutoff of 10 kDa, and centrifuged. Approximately 5-10 ml of clear liquid, ready for analysis, is obtained from a 20 ml milk sample. Both bovine and human milk samples have been successfully processed and analyzed by ion chromatography-mass spectrometry (IC-MS). Standard addition experiments show good recoveries. The repeatability of the analytical result for the same sample in multiple sample cleanup runs ranged from 3 to 6% R.S.D. This processing technique has also been successfully applied for the determination of iodide and thiocyanate in milk

  19. Optical methods for microstructure determination of doped samples

    Science.gov (United States)

    Ciosek, Jerzy F.

    2008-12-01

    The optical methods to determine refractive index profile of layered materials are commonly used with spectroscopic ellipsometry or transmittance/reflectance spectrometry. Measurements of spectral reflection and transmission usually permit to characterize optical materials and determine their refractive index. However, it is possible to characterize of samples with dopants, impurities as well as defects using optical methods. Microstructures of a hydrogenated crystalline Si wafer and a layer of SiO2 - ZrO2 composition are investigated. The first sample is a Si(001):H Czochralski grown single crystalline wafer with 50 nm thick surface Si02 layer. Hydrogen dose implantation (D continue to be an important issue in microelectronic device and sensor fabrication. Hydrogen-implanted silicon (Si: H) has become a topic of remarkable interest, mostly because of the potential of implantation-induced platelets and micro-cavities for the creation of gettering -active areas and for Si layer splitting. Oxygen precipitation and atmospheric impurity are analysed. The second sample is the layer of co-evaporated SiO2 and ZrO2 materials using simultaneously two electron beam guns in reactive evaporation methods. The composition structure was investigated by X-Ray photoelectron spectroscopy (XPS), and spectroscopic ellipsometry methods. A non-uniformity and composition of layer are analysed using average density method.

  20. Comparison of DNA preservation methods for environmental bacterial community samples.

    Science.gov (United States)

    Gray, Michael A; Pratte, Zoe A; Kellogg, Christina A

    2013-02-01

    Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard(™), RNAlater(®), DMSO-EDTA-salt (DESS), FTA(®) cards, and FTA Elute(®) cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA(®) cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard(™), RNAlater(®), and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  1. Transuranic waste characterization sampling and analysis methods manual. Revision 1

    International Nuclear Information System (INIS)

    Suermann, J.F.

    1996-04-01

    This Methods Manual provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Transuranic Waste Characterization Quality Assurance Program Plan (QAPP) for the Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program) and the WIPP Waste Analysis Plan. This Methods Manual includes all of the testing, sampling, and analytical methodologies accepted by DOE for use in implementing the Program requirements specified in the QAPP and the WIPP Waste Analysis Plan. The procedures in this Methods Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site-specific procedures. With some analytical methods, such as Gas Chromatography/Mass Spectrometry, the Methods Manual procedures may be used directly. With other methods, such as nondestructive characterization, the Methods Manual provides guidance rather than a step-by-step procedure. Sites must meet all of the specified quality control requirements of the applicable procedure. Each DOE site must document the details of the procedures it will use and demonstrate the efficacy of such procedures to the Manager, National TRU Program Waste Characterization, during Waste Characterization and Certification audits

  2. Non-uniform sampling and wide range angular spectrum method

    International Nuclear Information System (INIS)

    Kim, Yong-Hae; Byun, Chun-Won; Oh, Himchan; Lee, JaeWon; Pi, Jae-Eun; Heon Kim, Gi; Lee, Myung-Lae; Ryu, Hojun; Chu, Hye-Yong; Hwang, Chi-Sun

    2014-01-01

    A novel method is proposed for simulating free space field propagation from a source plane to a destination plane that is applicable for both small and large propagation distances. The angular spectrum method (ASM) was widely used for simulating near field propagation, but it caused a numerical error when the propagation distance was large because of aliasing due to under sampling. Band limited ASM satisfied the Nyquist condition on sampling by limiting a bandwidth of a propagation field to avoid an aliasing error so that it could extend the applicable propagation distance of the ASM. However, the band limited ASM also made an error due to the decrease of an effective sampling number in a Fourier space when the propagation distance was large. In the proposed wide range ASM, we use a non-uniform sampling in a Fourier space to keep a constant effective sampling number even though the propagation distance is large. As a result, the wide range ASM can produce simulation results with high accuracy for both far and near field propagation. For non-paraxial wave propagation, we applied the wide range ASM to a shifted destination plane as well. (paper)

  3. Standard methods for sampling freshwater fishes: Opportunities for international collaboration

    Science.gov (United States)

    Bonar, Scott A.; Mercado-Silva, Norman; Hubert, Wayne A.; Beard, Douglas; Dave, Göran; Kubečka, Jan; Graeb, Brian D. S.; Lester, Nigel P.; Porath, Mark T.; Winfield, Ian J.

    2017-01-01

    With publication of Standard Methods for Sampling North American Freshwater Fishes in 2009, the American Fisheries Society (AFS) recommended standard procedures for North America. To explore interest in standardizing at intercontinental scales, a symposium attended by international specialists in freshwater fish sampling was convened at the 145th Annual AFS Meeting in Portland, Oregon, in August 2015. Participants represented all continents except Australia and Antarctica and were employed by state and federal agencies, universities, nongovernmental organizations, and consulting businesses. Currently, standardization is practiced mostly in North America and Europe. Participants described how standardization has been important for management of long-term data sets, promoting fundamental scientific understanding, and assessing efficacy of large spatial scale management strategies. Academics indicated that standardization has been useful in fisheries education because time previously used to teach how sampling methods are developed is now more devoted to diagnosis and treatment of problem fish communities. Researchers reported that standardization allowed increased sample size for method validation and calibration. Group consensus was to retain continental standards where they currently exist but to further explore international and intercontinental standardization, specifically identifying where synergies and bridges exist, and identify means to collaborate with scientists where standardization is limited but interest and need occur.

  4. Soybean yield modeling using bootstrap methods for small samples

    Energy Technology Data Exchange (ETDEWEB)

    Dalposso, G.A.; Uribe-Opazo, M.A.; Johann, J.A.

    2016-11-01

    One of the problems that occur when working with regression models is regarding the sample size; once the statistical methods used in inferential analyzes are asymptotic if the sample is small the analysis may be compromised because the estimates will be biased. An alternative is to use the bootstrap methodology, which in its non-parametric version does not need to guess or know the probability distribution that generated the original sample. In this work we used a set of soybean yield data and physical and chemical soil properties formed with fewer samples to determine a multiple linear regression model. Bootstrap methods were used for variable selection, identification of influential points and for determination of confidence intervals of the model parameters. The results showed that the bootstrap methods enabled us to select the physical and chemical soil properties, which were significant in the construction of the soybean yield regression model, construct the confidence intervals of the parameters and identify the points that had great influence on the estimated parameters. (Author)

  5. A novel method for fission product noble gas sampling

    International Nuclear Information System (INIS)

    Jain, S.K.; Prakash, Vivek; Singh, G.K.; Vinay, Kr.; Awsthi, A.; Bihari, K.; Joyson, R.; Manu, K.; Gupta, Ashok

    2008-01-01

    Noble gases occur to some extent in the Earth's atmosphere, but the concentrations of all but argon are exceedingly low. Argon is plentiful, constituting almost 1 % of the air. Fission Product Noble Gases (FPNG) are produced by nuclear fission and large parts of FPNG is produced in Nuclear reactions. FPNG are b-j emitters and contributing significantly in public dose. During normal operation of reactor release of FPNG is negligible but its release increases in case of fuel failure. Xenon, a member of FPNG family helps in identification of fuel failure and its extent in PHWRs. Due to above reasons it becomes necessary to assess the FPNG release during operation of NPPs. Presently used methodology of assessment of FPNG, at almost all power stations is Computer based gamma ray spectrometry. This provides fission product Noble gases nuclide identification through peak search of spectra. The air sample for the same is collected by grab sampling method, which has inherent disadvantages. An alternate method was developed at Rajasthan Atomic Power Station (RAPS) - 3 and 4 for assessment of FPNG, which uses adsorption phenomena for collection of air samples. This report presents details of sampling method for FPNG and noble gases in different systems of Nuclear Power Plant. (author)

  6. Analytic continuation of quantum Monte Carlo data. Stochastic sampling method

    Energy Technology Data Exchange (ETDEWEB)

    Ghanem, Khaldoon; Koch, Erik [Institute for Advanced Simulation, Forschungszentrum Juelich, 52425 Juelich (Germany)

    2016-07-01

    We apply Bayesian inference to the analytic continuation of quantum Monte Carlo (QMC) data from the imaginary axis to the real axis. Demanding a proper functional Bayesian formulation of any analytic continuation method leads naturally to the stochastic sampling method (StochS) as the Bayesian method with the simplest prior, while it excludes the maximum entropy method and Tikhonov regularization. We present a new efficient algorithm for performing StochS that reduces computational times by orders of magnitude in comparison to earlier StochS methods. We apply the new algorithm to a wide variety of typical test cases: spectral functions and susceptibilities from DMFT and lattice QMC calculations. Results show that StochS performs well and is able to resolve sharp features in the spectrum.

  7. Entropic sampling in the path integral Monte Carlo method

    International Nuclear Information System (INIS)

    Vorontsov-Velyaminov, P N; Lyubartsev, A P

    2003-01-01

    We have extended the entropic sampling Monte Carlo method to the case of path integral representation of a quantum system. A two-dimensional density of states is introduced into path integral form of the quantum canonical partition function. Entropic sampling technique within the algorithm suggested recently by Wang and Landau (Wang F and Landau D P 2001 Phys. Rev. Lett. 86 2050) is then applied to calculate the corresponding entropy distribution. A three-dimensional quantum oscillator is considered as an example. Canonical distributions for a wide range of temperatures are obtained in a single simulation run, and exact data for the energy are reproduced

  8. Rapid screening method for plutonium in mixed waste samples

    International Nuclear Information System (INIS)

    Somers, W.; Culp, T.; Miller, R.

    1987-01-01

    A waste stream sampling program was undertaken to determine those waste streams which contained hazardous constituents, and would therefore be regulated as a hazardous waste under the Resource Conservation and Recovery Act. The waste streams also had the potential of containing radioactive material, either plutonium, americium, or depleted uranium. Because of the potential for contamination with radioactive material, a method of rapidly screening the liquid samples for radioactive material was required. A counting technique was devised to count a small aliquot of a sample, determine plutonium concentration, and allow the sample to be shipped the same day they were collected. This technique utilized the low energy photons (x-rays) that accompany α decay. This direct, non-destructive x-ray analysis was applied to quantitatively determine Pu-239 concentrations in industrial samples. Samples contained a Pu-239, Am-241 mixture; the ratio and/or concentrations of these two radionuclides was not constant. A computer program was designed and implemented to calculate Pu-239 activity and concentration (g/ml) using the 59.5 keV Am-241 peak to determine Am-241's contribution to the 17 keV region. Am's contribution was subtracted, yielding net counts in the 17 keV region due to Pu. 2 figs., 1 tab

  9. A method for sampling microbial aerosols using high altitude balloons.

    Science.gov (United States)

    Bryan, N C; Stewart, M; Granger, D; Guzik, T G; Christner, B C

    2014-12-01

    Owing to the challenges posed to microbial aerosol sampling at high altitudes, very little is known about the abundance, diversity, and extent of microbial taxa in the Earth-atmosphere system. To directly address this knowledge gap, we designed, constructed, and tested a system that passively samples aerosols during ascent through the atmosphere while tethered to a helium-filled latex sounding balloon. The sampling payload is ~ 2.7 kg and comprised of an electronics box and three sampling chambers (one serving as a procedural control). Each chamber is sealed with retractable doors that can be commanded to open and close at designated altitudes. The payload is deployed together with radio beacons that transmit GPS coordinates (latitude, longitude and altitude) in real time for tracking and recovery. A cut mechanism separates the payload string from the balloon at any desired altitude, returning all equipment safely to the ground on a parachute. When the chambers are opened, aerosol sampling is performed using the Rotorod® collection method (40 rods per chamber), with each rod passing through 0.035 m3 per km of altitude sampled. Based on quality control measurements, the collection of ~ 100 cells rod(-1) provided a 3-sigma confidence level of detection. The payload system described can be mated with any type of balloon platform and provides a tool for characterizing the vertical distribution of microorganisms in the troposphere and stratosphere. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. A Method for Choosing the Best Samples for Mars Sample Return.

    Science.gov (United States)

    Gordon, Peter R; Sephton, Mark A

    2018-05-01

    Success of a future Mars Sample Return mission will depend on the correct choice of samples. Pyrolysis-FTIR can be employed as a triage instrument for Mars Sample Return. The technique can thermally dissociate minerals and organic matter for detection. Identification of certain mineral types can determine the habitability of the depositional environment, past or present, while detection of organic matter may suggest past or present habitation. In Mars' history, the Theiikian era represents an attractive target for life search missions and the acquisition of samples. The acidic and increasingly dry Theiikian may have been habitable and followed a lengthy neutral and wet period in Mars' history during which life could have originated and proliferated to achieve relatively abundant levels of biomass with a wide distribution. Moreover, the sulfate minerals produced in the Theiikian are also known to be good preservers of organic matter. We have used pyrolysis-FTIR and samples from a Mars analog ferrous acid stream with a thriving ecosystem to test the triage concept. Pyrolysis-FTIR identified those samples with the greatest probability of habitability and habitation. A three-tier scoring system was developed based on the detection of (i) organic signals, (ii) carbon dioxide and water, and (iii) sulfur dioxide. The presence of each component was given a score of A, B, or C depending on whether the substance had been detected, tentatively detected, or not detected, respectively. Single-step (for greatest possible sensitivity) or multistep (for more diagnostic data) pyrolysis-FTIR methods informed the assignments. The system allowed the highest-priority samples to be categorized as AAA (or A*AA if the organic signal was complex), while the lowest-priority samples could be categorized as CCC. Our methods provide a mechanism with which to rank samples and identify those that should take the highest priority for return to Earth during a Mars Sample Return mission. Key Words

  11. Effectiveness of disinfectant wipes for decontamination of bacteria on patients' environmental and medical equipment surfaces at Siriraj Hospital.

    Science.gov (United States)

    Seenama, Chakkraphong; Tachasirinugune, Peenithi; Jintanothaitavorn, Duangporn; Kachintorn, Kanchana; Thamlikitkul, Visanu

    2013-02-01

    To determine the effectiveness of Virusolve+ disinfectant wipes and PAL disinfectant wipes for decontamination of inoculated bacteria on patients' environmental and medical equipment surfaces at Siriraj Hospital. Tryptic soy broths containing MRSA and XDR A. baumannii were painted onto the surfaces of patient's stainless steel bed rail, patient's fiber footboard, control panel of infusion pump machine and control panel of respirator. The contaminated surfaces were cleaned by either tap water, tap water containing detergent, Virusolve+ disinfectant wipes or PAL disinfectant wipes. The surfaces without any cleaning procedures served as the control surface. The contaminated surfaces cleaned with the aforementioned procedures and control surfaces were swabbed with cotton swabs. The swabs were streaked on agar plates to determine the presence of MRSA and XDR A. baumannii. MRSA and XDR A. baumannii were recovered from all control surfaces. All surfaces cleaned with tap water or tap water containing detergent revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with tap water containing detergent were less than those cleaned with tap water alone. All surfaces cleaned with PAL disinfectant wipes also revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with PAL disinfectant wipes were less than those cleaned with tap water containing detergent. No bacteria were recovered from all surfaces cleaned with Virusolve+ disinfectant wipes. Virusolve+ disinfectant wipes were more effective than tap water; tap water containing detergent and PAL disinfectant wipes for decontamination of bacteria inoculated on patients environmental and medical equipment surfaces at Siriraj Hospital.

  12. Empirical method for matrix effects correction in liquid samples

    International Nuclear Information System (INIS)

    Vigoda de Leyt, Dora; Vazquez, Cristina

    1987-01-01

    A simple method for the determination of Cr, Ni and Mo in stainless steels is presented. In order to minimize the matrix effects, the conditions of liquid system to dissolve stainless steels chips has been developed. Pure element solutions were used as standards. Preparation of synthetic solutions with all the elements of steel and also mathematic corrections are avoided. It results in a simple chemical operation which simplifies the method of analysis. The variance analysis of the results obtained with steel samples show that the three elements may be determined from the comparison with the analytical curves obtained with the pure elements if the same parameters in the calibration curves are used. The accuracy and the precision were checked against other techniques using the British Chemical Standards of the Bureau of Anlysed Samples Ltd. (England). (M.E.L.) [es

  13. Harmonisation of microbial sampling and testing methods for distillate fuels

    Energy Technology Data Exchange (ETDEWEB)

    Hill, G.C.; Hill, E.C. [ECHA Microbiology Ltd., Cardiff (United Kingdom)

    1995-05-01

    Increased incidence of microbial infection in distillate fuels has led to a demand for organisations such as the Institute of Petroleum to propose standards for microbiological quality, based on numbers of viable microbial colony forming units. Variations in quality requirements, and in the spoilage significance of contaminating microbes plus a tendency for temporal and spatial changes in the distribution of microbes, makes such standards difficult to implement. The problem is compounded by a diversity in the procedures employed for sampling and testing for microbial contamination and in the interpretation of the data obtained. The following paper reviews these problems and describes the efforts of The Institute of Petroleum Microbiology Fuels Group to address these issues and in particular to bring about harmonisation of sampling and testing methods. The benefits and drawbacks of available test methods, both laboratory based and on-site, are discussed.

  14. A direct sampling method to an inverse medium scattering problem

    KAUST Repository

    Ito, Kazufumi

    2012-01-10

    In this work we present a novel sampling method for time harmonic inverse medium scattering problems. It provides a simple tool to directly estimate the shape of the unknown scatterers (inhomogeneous media), and it is applicable even when the measured data are only available for one or two incident directions. A mathematical derivation is provided for its validation. Two- and three-dimensional numerical simulations are presented, which show that the method is accurate even with a few sets of scattered field data, computationally efficient, and very robust with respect to noises in the data. © 2012 IOP Publishing Ltd.

  15. Rock sampling. [method for controlling particle size distribution

    Science.gov (United States)

    Blum, P. (Inventor)

    1971-01-01

    A method for sampling rock and other brittle materials and for controlling resultant particle sizes is described. The method involves cutting grooves in the rock surface to provide a grouping of parallel ridges and subsequently machining the ridges to provide a powder specimen. The machining step may comprise milling, drilling, lathe cutting or the like; but a planing step is advantageous. Control of the particle size distribution is effected primarily by changing the height and width of these ridges. This control exceeds that obtainable by conventional grinding.

  16. Characterization of hazardous waste sites: a methods manual. Volume 2. Available sampling methods (second edition)

    International Nuclear Information System (INIS)

    Ford, P.J.; Turina, P.J.; Seely, D.E.

    1984-12-01

    Investigations at hazardous waste sites and sites of chemical spills often require on-site measurements and sampling activities to assess the type and extent of contamination. This document is a compilation of sampling methods and materials suitable to address most needs that arise during routine waste site and hazardous spill investigations. The sampling methods presented in this document are compiled by media, and were selected on the basis of practicality, economics, representativeness, compatability with analytical considerations, and safety, as well as other criteria. In addition to sampling procedures, sample handling and shipping, chain-of-custody procedures, instrument certification, equipment fabrication, and equipment decontamination procedures are described. Sampling methods for soil, sludges, sediments, and bulk materials cover the solids medium. Ten methods are detailed for surface waters, groundwater and containerized liquids; twelve are presented for ambient air, soil gases and vapors, and headspace gases. A brief discussion of ionizing radiation survey instruments is also provided

  17. The experience sampling method: Investigating students' affective experience

    Science.gov (United States)

    Nissen, Jayson M.; Stetzer, MacKenzie R.; Shemwell, Jonathan T.

    2013-01-01

    Improving non-cognitive outcomes such as attitudes, efficacy, and persistence in physics courses is an important goal of physics education. This investigation implemented an in-the-moment surveying technique called the Experience Sampling Method (ESM) [1] to measure students' affective experience in physics. Measurements included: self-efficacy, cognitive efficiency, activation, intrinsic motivation, and affect. Data are presented that show contrasts in students' experiences (e.g., in physics vs. non-physics courses).

  18. Method for evaluation of radiative properties of glass samples

    Energy Technology Data Exchange (ETDEWEB)

    Mohelnikova, Jitka [Faculty of Civil Engineering, Brno University of Technology, Veveri 95, 602 00 Brno (Czech Republic)], E-mail: mohelnikova.j@fce.vutbr.cz

    2008-04-15

    The paper presents a simple calculation method which serves for an evaluation of radiative properties of window glasses. The method is based on a computer simulation model of the energy balance of a thermally insulated box with selected glass samples. A temperature profile of the air inside of the box with a glass sample exposed to affecting radiation was determined for defined boundary conditions. The spectral range of the radiation was considered in the interval between 280 and 2500 nm. This interval is adequate to the spectral range of solar radiation affecting windows in building facades. The air temperature rise within the box was determined in a response to the affecting radiation in the time between the beginning of the radiation exposition and the time of steady-state thermal conditions. The steady state temperature inside of the insulated box serves for the evaluation of the box energy balance and determination of the glass sample radiative properties. These properties are represented by glass characteristics as mean values of transmittance, reflectance and absorptance calculated for a defined spectral range. The data of the computer simulations were compared to experimental measurements on a real model of the insulated box. Results of both the calculations and measurements are in a good compliance. The method is recommended for preliminary evaluation of window glass radiative properties which serve as data for energy evaluation of buildings.

  19. Radiochemistry methods in DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Fadeff, S.K.; Goheen, S.C.

    1994-08-01

    Current standard sources of radiochemistry methods are often inappropriate for use in evaluating US Department of Energy environmental and waste management (DOE/EW) samples. Examples of current sources include EPA, ASTM, Standard Methods for the Examination of Water and Wastewater and HASL-300. Applicability of these methods is limited to specific matrices (usually water), radiation levels (usually environmental levels), and analytes (limited number). Radiochemistry methods in DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) attempt to fill the applicability gap that exists between standard methods and those needed for DOE/EM activities. The Radiochemistry chapter in DOE Methods includes an ''analysis and reporting'' guidance section as well as radiochemistry methods. A basis for identifying the DOE/EM radiochemistry needs is discussed. Within this needs framework, the applicability of standard methods and targeted new methods is identified. Sources of new methods (consolidated methods from DOE laboratories and submissions from individuals) and the methods review process will be discussed. The processes involved in generating consolidated methods add editing individually submitted methods will be compared. DOE Methods is a living document and continues to expand by adding various kinds of methods. Radiochemistry methods are highlighted in this paper. DOE Methods is intended to be a resource for methods applicable to DOE/EM problems. Although it is intended to support DOE, the guidance and methods are not necessarily exclusive to DOE. The document is available at no cost through the Laboratory Management Division of DOE, Office of Technology Development

  20. Application of WSP method in analysis of environmental samples

    International Nuclear Information System (INIS)

    Stacho, M.; Slugen, V.; Hinca, R.; Sojak, S.; Krnac, S.

    2014-01-01

    Detection of activity in natural samples is specific especially because of its low level and high background interferences. Reduction of background interferences could be reached using low background chamber. Measurement geometry in shape of Marinelli beaker is commonly used according to low level of activity in natural samples. The Peak Net Area (PNA) method is the world-wide accepted technique for analysis of gamma-ray spectra. It is based on the net area calculation of the full energy peak, therefore, it takes into account only a fraction of measured gamma-ray spectrum. On the other hand, the Whole Spectrum Processing (WSP) approach to the gamma analysis makes possible to use entire information being in the spectrum. This significantly raises efficiency and improves energy resolution of the analysis. A principal step for the WSP application is building up the suitable response operator. Problems are put in an appearance when suitable standard calibration sources are unavailable. It may be occurred in the case of large volume samples and/or in the analysis of high energy range. Combined experimental and mathematical calibration may be a suitable solution. Many different detectors have been used to register the gamma ray and its energy. HPGe detectors produce the highest resolution commonly available today. Therefore they are they the most often used detectors in natural samples activity analysis. Scintillation detectors analysed using PNA method could be also used in simple cases, but for complicated spectra are practically inapplicable. WSP approach improves resolution of scintillation detectors and expands their applicability. WSP method allowed significant improvement of the energetic resolution and separation of "1"3"7Cs 661 keV peak from "2"1"4Bi 609 keV peak. At the other hand the statistical fluctuations in the lower part of the spectrum highlighted by background subtraction causes that this part is still not reliably analyzable. (authors)

  1. Analytical Method to Estimate the Complex Permittivity of Oil Samples

    Directory of Open Access Journals (Sweden)

    Lijuan Su

    2018-03-01

    Full Text Available In this paper, an analytical method to estimate the complex dielectric constant of liquids is presented. The method is based on the measurement of the transmission coefficient in an embedded microstrip line loaded with a complementary split ring resonator (CSRR, which is etched in the ground plane. From this response, the dielectric constant and loss tangent of the liquid under test (LUT can be extracted, provided that the CSRR is surrounded by such LUT, and the liquid level extends beyond the region where the electromagnetic fields generated by the CSRR are present. For that purpose, a liquid container acting as a pool is added to the structure. The main advantage of this method, which is validated from the measurement of the complex dielectric constant of olive and castor oil, is that reference samples for calibration are not required.

  2. Method for fractional solid-waste sampling and chemical analysis

    DEFF Research Database (Denmark)

    Riber, Christian; Rodushkin, I.; Spliid, Henrik

    2007-01-01

    four subsampling methods and five digestion methods, paying attention to the heterogeneity and the material characteristics of the waste fractions, it was possible to determine 61 substances with low detection limits, reasonable variance, and high accuracy. For most of the substances of environmental...... of variance (20-85% of the overall variation). Only by increasing the sample size significantly can this variance be reduced. The accuracy and short-term reproducibility of the chemical characterization were good, as determined by the analysis of several relevant certified reference materials. Typically, six...... to eight different certified reference materials representing a range of concentrations levels and matrix characteristics were included. Based on the documentation provided, the methods introduced were considered satisfactory for characterization of the chemical composition of waste-material fractions...

  3. Comparison between powder and slices diffraction methods in teeth samples

    Energy Technology Data Exchange (ETDEWEB)

    Colaco, Marcos V.; Barroso, Regina C. [Universidade do Estado do Rio de Janeiro (IF/UERJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Aplicada; Porto, Isabel M. [Universidade Estadual de Campinas (FOP/UNICAMP), Piracicaba, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia; Gerlach, Raquel F. [Universidade de Sao Paulo (FORP/USP), Rieirao Preto, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia, Estomatologia e Fisiologia; Costa, Fanny N. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (LIN/COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear

    2011-07-01

    Propose different methods to obtain crystallographic information about biological materials are important since powder method is a nondestructive method. Slices are an approximation of what would be an in vivo analysis. Effects of samples preparation cause differences in scattering profiles compared with powder method. The main inorganic component of bones and teeth is a calcium phosphate mineral whose structure closely resembles hydroxyapatite (HAp). The hexagonal symmetry, however, seems to work well with the powder diffraction data, and the crystal structure of HAp is usually described in space group P63/m. Were analyzed ten third molar teeth. Five teeth were separated in enamel, detin and circumpulpal detin powder and five in slices. All the scattering profile measurements were carried out at the X-ray diffraction beamline (XRD1) at the National Synchrotron Light Laboratory - LNLS, Campinas, Brazil. The LNLS synchrotron light source is composed of a 1.37 GeV electron storage ring, delivering approximately 4x10{sup -1}0 photons/s at 8 keV. A double-crystal Si(111) pre-monochromator, upstream of the beamline, was used to select a small energy bandwidth at 11 keV . Scattering signatures were obtained at intervals of 0.04 deg for angles from 24 deg to 52 deg. The human enamel experimental crystallite size obtained in this work were 30(3)nm (112 reflection) and 30(3)nm (300 reflection). These values were obtained from measurements of powdered enamel. When comparing the slice obtained 58(8)nm (112 reflection) and 37(7)nm (300 reflection) enamel diffraction patterns with those generated by the powder specimens, a few differences emerge. This work shows differences between powder and slices methods, separating characteristics of sample of the method's influence. (author)

  4. Comparison between powder and slices diffraction methods in teeth samples

    International Nuclear Information System (INIS)

    Colaco, Marcos V.; Barroso, Regina C.; Porto, Isabel M.; Gerlach, Raquel F.; Costa, Fanny N.

    2011-01-01

    Propose different methods to obtain crystallographic information about biological materials are important since powder method is a nondestructive method. Slices are an approximation of what would be an in vivo analysis. Effects of samples preparation cause differences in scattering profiles compared with powder method. The main inorganic component of bones and teeth is a calcium phosphate mineral whose structure closely resembles hydroxyapatite (HAp). The hexagonal symmetry, however, seems to work well with the powder diffraction data, and the crystal structure of HAp is usually described in space group P63/m. Were analyzed ten third molar teeth. Five teeth were separated in enamel, detin and circumpulpal detin powder and five in slices. All the scattering profile measurements were carried out at the X-ray diffraction beamline (XRD1) at the National Synchrotron Light Laboratory - LNLS, Campinas, Brazil. The LNLS synchrotron light source is composed of a 1.37 GeV electron storage ring, delivering approximately 4x10 -1 0 photons/s at 8 keV. A double-crystal Si(111) pre-monochromator, upstream of the beamline, was used to select a small energy bandwidth at 11 keV . Scattering signatures were obtained at intervals of 0.04 deg for angles from 24 deg to 52 deg. The human enamel experimental crystallite size obtained in this work were 30(3)nm (112 reflection) and 30(3)nm (300 reflection). These values were obtained from measurements of powdered enamel. When comparing the slice obtained 58(8)nm (112 reflection) and 37(7)nm (300 reflection) enamel diffraction patterns with those generated by the powder specimens, a few differences emerge. This work shows differences between powder and slices methods, separating characteristics of sample of the method's influence. (author)

  5. Radiochemistry methods in DOE Methods for Evaluating Environmental and Waste Management Samples: Addressing new challenges

    International Nuclear Information System (INIS)

    Fadeff, S.K.; Goheen, S.C.; Riley, R.G.

    1994-01-01

    Radiochemistry methods in Department of Energy Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) add to the repertoire of other standard methods in support of U.S. Department of Energy environmental restoration and waste management (DOE/EM) radiochemical characterization activities. Current standard sources of radiochemistry methods are not always applicable for evaluating DOE/EM samples. Examples of current sources include those provided by the US Environmental Protection Agency, the American Society for Testing and Materials, Standard Methods for the Examination of Water and Wastewater, and Environmental Measurements Laboratory Procedures Manual (HASL-300). The applicability of these methods is generally limited to specific matrices (usually water), low-level radioactive samples, and a limited number of analytes. DOE Methods complements these current standard methods by addressing the complexities of EM characterization needs. The process for determining DOE/EM radiochemistry characterization needs is discussed. In this context of DOE/EM needs, the applicability of other sources of standard radiochemistry methods is defined, and gaps in methodology are identified. Current methods in DOE Methods and the EM characterization needs they address are discussed. Sources of new methods and the methods incorporation process are discussed. The means for individuals to participate in (1) identification of DOE/EM needs, (2) the methods incorporation process, and (3) submission of new methods are identified

  6. A direct sampling method for inverse electromagnetic medium scattering

    KAUST Repository

    Ito, Kazufumi

    2013-09-01

    In this paper, we study the inverse electromagnetic medium scattering problem of estimating the support and shape of medium scatterers from scattered electric/magnetic near-field data. We shall develop a novel direct sampling method based on an analysis of electromagnetic scattering and the behavior of the fundamental solution. It is applicable to a few incident fields and needs only to compute inner products of the measured scattered field with the fundamental solutions located at sampling points. Hence, it is strictly direct, computationally very efficient and highly robust to the presence of data noise. Two- and three-dimensional numerical experiments indicate that it can provide reliable support estimates for multiple scatterers in the case of both exact and highly noisy data. © 2013 IOP Publishing Ltd.

  7. Monte Carlo burnup codes acceleration using the correlated sampling method

    International Nuclear Information System (INIS)

    Dieudonne, C.

    2013-01-01

    For several years, Monte Carlo burnup/depletion codes have appeared, which couple Monte Carlo codes to simulate the neutron transport to deterministic methods, which handle the medium depletion due to the neutron flux. Solving Boltzmann and Bateman equations in such a way allows to track fine 3-dimensional effects and to get rid of multi-group hypotheses done by deterministic solvers. The counterpart is the prohibitive calculation time due to the Monte Carlo solver called at each time step. In this document we present an original methodology to avoid the repetitive and time-expensive Monte Carlo simulations, and to replace them by perturbation calculations: indeed the different burnup steps may be seen as perturbations of the isotopic concentration of an initial Monte Carlo simulation. In a first time we will present this method, and provide details on the perturbative technique used, namely the correlated sampling. In a second time we develop a theoretical model to study the features of the correlated sampling method to understand its effects on depletion calculations. In a third time the implementation of this method in the TRIPOLI-4 code will be discussed, as well as the precise calculation scheme used to bring important speed-up of the depletion calculation. We will begin to validate and optimize the perturbed depletion scheme with the calculation of a REP-like fuel cell depletion. Then this technique will be used to calculate the depletion of a REP-like assembly, studied at beginning of its cycle. After having validated the method with a reference calculation we will show that it can speed-up by nearly an order of magnitude standard Monte-Carlo depletion codes. (author) [fr

  8. A GPU code for analytic continuation through a sampling method

    Directory of Open Access Journals (Sweden)

    Johan Nordström

    2016-01-01

    Full Text Available We here present a code for performing analytic continuation of fermionic Green’s functions and self-energies as well as bosonic susceptibilities on a graphics processing unit (GPU. The code is based on the sampling method introduced by Mishchenko et al. (2000, and is written for the widely used CUDA platform from NVidia. Detailed scaling tests are presented, for two different GPUs, in order to highlight the advantages of this code with respect to standard CPU computations. Finally, as an example of possible applications, we provide the analytic continuation of model Gaussian functions, as well as more realistic test cases from many-body physics.

  9. Methods of scaling threshold color difference using printed samples

    Science.gov (United States)

    Huang, Min; Cui, Guihua; Liu, Haoxue; Luo, M. Ronnier

    2012-01-01

    A series of printed samples on substrate of semi-gloss paper and with the magnitude of threshold color difference were prepared for scaling the visual color difference and to evaluate the performance of different method. The probabilities of perceptibly was used to normalized to Z-score and different color differences were scaled to the Z-score. The visual color difference was got, and checked with the STRESS factor. The results indicated that only the scales have been changed but the relative scales between pairs in the data are preserved.

  10. National comparison on volume sample activity measurement methods

    International Nuclear Information System (INIS)

    Sahagia, M.; Grigorescu, E.L.; Popescu, C.; Razdolescu, C.

    1992-01-01

    A national comparison on volume sample activity measurements methods may be regarded as a step toward accomplishing the traceability of the environmental and food chain activity measurements to national standards. For this purpose, the Radionuclide Metrology Laboratory has distributed 137 Cs and 134 Cs water-equivalent solid standard sources to 24 laboratories having responsibilities in this matter. Every laboratory has to measure the activity of the received source(s) by using its own standards, equipment and methods and report the obtained results to the organizer. The 'measured activities' will be compared with the 'true activities'. A final report will be issued, which plans to evaluate the national level of precision of such measurements and give some suggestions for improvement. (Author)

  11. Preliminary assessment on exposure of four typical populations to potentially toxic metals by means of skin wipes under the influence of haze pollution.

    Science.gov (United States)

    Cao, Zhiguo; Wang, Mengmeng; Chen, Qiaoying; Zhang, Yajie; Dong, Wenjing; Yang, Tianfang; Yan, Guangxuan; Zhang, Xin; Pi, Yunqing; Xi, Benye; Bu, Qingwei

    2018-02-01

    To investigate the exposure risk of human beings to nine potentially toxic metals (PTMs), namely, Cu, Cr, Zn, As, Cd, Pb, Ni, Mn, and Co, skin wipe samples were collected from four types of populations, namely, children, undergraduates, security guards, and professional drivers, under different haze pollution levels in Xinxiang, China by using Ghost wipes. The Ghost wipes were quantitatively analyzed by inductively coupled plasma mass spectrometry (ICP-MS) after microwave digestion. Generally, Zn (ND-1350μg/m 2 for undergraduates, ND-2660μg/m 2 for security guards, ND-2460μg/m 2 for children, and ND-2530μg/m 2 for professional drivers) showed the highest concentration among the four populations, followed by Cu (0.02-83.4μg/m 2 for undergraduates, ND-70.2μg/m 2 for security guards, 23.2-487μg/m 2 for children, and ND-116μg/m 2 for professional drivers). As (ND-5.7μg/m 2 for undergraduates, ND-2.3μg/m 2 for security guards, ND-21.1μg/m 2 for children, and ND-11.0μg/m 2 for professional drivers) and Co (ND-6.0μg/m 2 for undergraduates, ND-7.9μg/m 2 for security guards, ND-13.4μg/m 2 for children, and ND-2.1μg/m 2 for professional drivers) showed the lowest concentrations in all populations. Remarkable differences were found among the four populations and PTM levels decreased in the following order: children, professional drivers, security guards, and undergraduates. Gender variation was discovered for undergraduates and children. Generally, PTM contamination in skin wipes collected during a light haze pollution level was generally higher than that during a heavy haze pollution level, but PTM contamination was comparable between the two haze pollution levels for children. Non-carcinogenic exposure risks to As, Cd, and Pb for all populations were higher than those for the other six elements but all of them were within the acceptable safety threshold, indicating no apparent non-carcinogenic risk. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Verification of spectrophotometric method for nitrate analysis in water samples

    Science.gov (United States)

    Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu

    2017-12-01

    The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.

  13. Methods to maximise recovery of environmental DNA from water samples.

    Directory of Open Access Journals (Sweden)

    Rheyda Hinlo

    Full Text Available The environmental DNA (eDNA method is a detection technique that is rapidly gaining credibility as a sensitive tool useful in the surveillance and monitoring of invasive and threatened species. Because eDNA analysis often deals with small quantities of short and degraded DNA fragments, methods that maximize eDNA recovery are required to increase detectability. In this study, we performed experiments at different stages of the eDNA analysis to show which combinations of methods give the best recovery rate for eDNA. Using Oriental weatherloach (Misgurnus anguillicaudatus as a study species, we show that various combinations of DNA capture, preservation and extraction methods can significantly affect DNA yield. Filtration using cellulose nitrate filter paper preserved in ethanol or stored in a -20°C freezer and extracted with the Qiagen DNeasy kit outperformed other combinations in terms of cost and efficiency of DNA recovery. Our results support the recommendation to filter water samples within 24hours but if this is not possible, our results suggest that refrigeration may be a better option than freezing for short-term storage (i.e., 3-5 days. This information is useful in designing eDNA detection of low-density invasive or threatened species, where small variations in DNA recovery can signify the difference between detection success or failure.

  14. BMAA extraction of cyanobacteria samples: which method to choose?

    Science.gov (United States)

    Lage, Sandra; Burian, Alfred; Rasmussen, Ulla; Costa, Pedro Reis; Annadotter, Heléne; Godhe, Anna; Rydberg, Sara

    2016-01-01

    β-N-Methylamino-L-alanine (BMAA), a neurotoxin reportedly produced by cyanobacteria, diatoms and dinoflagellates, is proposed to be linked to the development of neurological diseases. BMAA has been found in aquatic and terrestrial ecosystems worldwide, both in its phytoplankton producers and in several invertebrate and vertebrate organisms that bioaccumulate it. LC-MS/MS is the most frequently used analytical technique in BMAA research due to its high selectivity, though consensus is lacking as to the best extraction method to apply. This study accordingly surveys the efficiency of three extraction methods regularly used in BMAA research to extract BMAA from cyanobacteria samples. The results obtained provide insights into possible reasons for the BMAA concentration discrepancies in previous publications. In addition and according to the method validation guidelines for analysing cyanotoxins, the TCA protein precipitation method, followed by AQC derivatization and LC-MS/MS analysis, is now validated for extracting protein-bound (after protein hydrolysis) and free BMAA from cyanobacteria matrix. BMAA biological variability was also tested through the extraction of diatom and cyanobacteria species, revealing a high variance in BMAA levels (0.0080-2.5797 μg g(-1) DW).

  15. Clustering Methods with Qualitative Data: a Mixed-Methods Approach for Prevention Research with Small Samples.

    Science.gov (United States)

    Henry, David; Dymnicki, Allison B; Mohatt, Nathaniel; Allen, James; Kelly, James G

    2015-10-01

    Qualitative methods potentially add depth to prevention research but can produce large amounts of complex data even with small samples. Studies conducted with culturally distinct samples often produce voluminous qualitative data but may lack sufficient sample sizes for sophisticated quantitative analysis. Currently lacking in mixed-methods research are methods allowing for more fully integrating qualitative and quantitative analysis techniques. Cluster analysis can be applied to coded qualitative data to clarify the findings of prevention studies by aiding efforts to reveal such things as the motives of participants for their actions and the reasons behind counterintuitive findings. By clustering groups of participants with similar profiles of codes in a quantitative analysis, cluster analysis can serve as a key component in mixed-methods research. This article reports two studies. In the first study, we conduct simulations to test the accuracy of cluster assignment using three different clustering methods with binary data as produced when coding qualitative interviews. Results indicated that hierarchical clustering, K-means clustering, and latent class analysis produced similar levels of accuracy with binary data and that the accuracy of these methods did not decrease with samples as small as 50. Whereas the first study explores the feasibility of using common clustering methods with binary data, the second study provides a "real-world" example using data from a qualitative study of community leadership connected with a drug abuse prevention project. We discuss the implications of this approach for conducting prevention research, especially with small samples and culturally distinct communities.

  16. Clustering Methods with Qualitative Data: A Mixed Methods Approach for Prevention Research with Small Samples

    Science.gov (United States)

    Henry, David; Dymnicki, Allison B.; Mohatt, Nathaniel; Allen, James; Kelly, James G.

    2016-01-01

    Qualitative methods potentially add depth to prevention research, but can produce large amounts of complex data even with small samples. Studies conducted with culturally distinct samples often produce voluminous qualitative data, but may lack sufficient sample sizes for sophisticated quantitative analysis. Currently lacking in mixed methods research are methods allowing for more fully integrating qualitative and quantitative analysis techniques. Cluster analysis can be applied to coded qualitative data to clarify the findings of prevention studies by aiding efforts to reveal such things as the motives of participants for their actions and the reasons behind counterintuitive findings. By clustering groups of participants with similar profiles of codes in a quantitative analysis, cluster analysis can serve as a key component in mixed methods research. This article reports two studies. In the first study, we conduct simulations to test the accuracy of cluster assignment using three different clustering methods with binary data as produced when coding qualitative interviews. Results indicated that hierarchical clustering, K-Means clustering, and latent class analysis produced similar levels of accuracy with binary data, and that the accuracy of these methods did not decrease with samples as small as 50. Whereas the first study explores the feasibility of using common clustering methods with binary data, the second study provides a “real-world” example using data from a qualitative study of community leadership connected with a drug abuse prevention project. We discuss the implications of this approach for conducting prevention research, especially with small samples and culturally distinct communities. PMID:25946969

  17. Agricultural and residential pesticides in wipe samples from farmworker family residences in North Carolina and Virginia.

    OpenAIRE

    Quandt, Sara A; Arcury, Thomas A; Rao, Pamela; Snively, Beverly M; Camann, David E; Doran, Alicia M; Yau, Alice Y; Hoppin, Jane A; Jackson, David S

    2004-01-01

    Children of farmworkers can be exposed to pesticides through multiple pathways, including agricultural take-home and drift as well as residential applications. Because farmworker families often live in poor-quality housing, the exposure from residential pesticide use may be substantial. We measured eight locally reported agricultural pesticides and 13 pesticides commonly found in U.S. houses in residences of 41 farmworker families with at least one child < 7 years of age in western North Caro...

  18. An adaptive sampling and windowing interrogation method in PIV

    Science.gov (United States)

    Theunissen, R.; Scarano, F.; Riethmuller, M. L.

    2007-01-01

    This study proposes a cross-correlation based PIV image interrogation algorithm that adapts the number of interrogation windows and their size to the image properties and to the flow conditions. The proposed methodology releases the constraint of uniform sampling rate (Cartesian mesh) and spatial resolution (uniform window size) commonly adopted in PIV interrogation. Especially in non-optimal experimental conditions where the flow seeding is inhomogeneous, this leads either to loss of robustness (too few particles per window) or measurement precision (too large or coarsely spaced interrogation windows). Two criteria are investigated, namely adaptation to the local signal content in the image and adaptation to local flow conditions. The implementation of the adaptive criteria within a recursive interrogation method is described. The location and size of the interrogation windows are locally adapted to the image signal (i.e., seeding density). Also the local window spacing (commonly set by the overlap factor) is put in relation with the spatial variation of the velocity field. The viability of the method is illustrated over two experimental cases where the limitation of a uniform interrogation approach appears clearly: a shock-wave-boundary layer interaction and an aircraft vortex wake. The examples show that the spatial sampling rate can be adapted to the actual flow features and that the interrogation window size can be arranged so as to follow the spatial distribution of seeding particle images and flow velocity fluctuations. In comparison with the uniform interrogation technique, the spatial resolution is locally enhanced while in poorly seeded regions the level of robustness of the analysis (signal-to-noise ratio) is kept almost constant.

  19. Organophosphate flame retardants and plasticizers in indoor dust, air and window wipes in newly built low-energy preschools.

    Science.gov (United States)

    Persson, Josefin; Wang, Thanh; Hagberg, Jessika

    2018-07-01

    The construction of extremely airtight and energy efficient low-energy buildings is achieved by using functional building materials, such as age-resistant plastics, insulation, adhesives, and sealants. Additives such as organophosphate flame retardants (OPFRs) can be added to some of these building materials as flame retardants and plasticizers. Some OPFRs are considered persistent, bioaccumulative and toxic. Therefore, in this pilot study, the occurrence and distribution of nine OPFRs were determined for dust, air, and window wipe samples collected in newly built low-energy preschools with and without environmental certifications. Tris(1,3-dichloroisopropyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP) were detected in all indoor dust samples at concentrations ranging from 0.014 to 10μg/g and 0.0069 to 79μg/g, respectively. Only six OPFRs (predominantly chlorinated OPFRs) were detected in the indoor air. All nine OPFRs were found on the window surfaces and the highest concentrations, which occurred in the reference preschool, were measured for 2-ethylhexyl diphenyl phosphate (EHDPP) (maximum concentration: 1500ng/m 2 ). Interestingly, the OPFR levels in the environmental certified low-energy preschools were lower than those in the reference preschool and the non-certified low-energy preschool, probably attributed to the usage of environmental friendly and low-emitting building materials, interior decorations, and consumer products. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. A Noise Reduction Method for Dual-Mass Micro-Electromechanical Gyroscopes Based on Sample Entropy Empirical Mode Decomposition and Time-Frequency Peak Filtering.

    Science.gov (United States)

    Shen, Chong; Li, Jie; Zhang, Xiaoming; Shi, Yunbo; Tang, Jun; Cao, Huiliang; Liu, Jun

    2016-05-31

    The different noise components in a dual-mass micro-electromechanical system (MEMS) gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN), electronic-thermal noise (ETN), flicker noise (FN) and Coriolis signal in-phase noise (IPN). The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD) and time-frequency peak filtering (TFPF). There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs) by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods.

  1. A Noise Reduction Method for Dual-Mass Micro-Electromechanical Gyroscopes Based on Sample Entropy Empirical Mode Decomposition and Time-Frequency Peak Filtering

    Directory of Open Access Journals (Sweden)

    Chong Shen

    2016-05-01

    Full Text Available The different noise components in a dual-mass micro-electromechanical system (MEMS gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN, electronic-thermal noise (ETN, flicker noise (FN and Coriolis signal in-phase noise (IPN. The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD and time-frequency peak filtering (TFPF. There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods.

  2. Martian Radiative Transfer Modeling Using the Optimal Spectral Sampling Method

    Science.gov (United States)

    Eluszkiewicz, J.; Cady-Pereira, K.; Uymin, G.; Moncet, J.-L.

    2005-01-01

    The large volume of existing and planned infrared observations of Mars have prompted the development of a new martian radiative transfer model that could be used in the retrievals of atmospheric and surface properties. The model is based on the Optimal Spectral Sampling (OSS) method [1]. The method is a fast and accurate monochromatic technique applicable to a wide range of remote sensing platforms (from microwave to UV) and was originally developed for the real-time processing of infrared and microwave data acquired by instruments aboard the satellites forming part of the next-generation global weather satellite system NPOESS (National Polarorbiting Operational Satellite System) [2]. As part of our on-going research related to the radiative properties of the martian polar caps, we have begun the development of a martian OSS model with the goal of using it to perform self-consistent atmospheric corrections necessary to retrieve caps emissivity from the Thermal Emission Spectrometer (TES) spectra. While the caps will provide the initial focus area for applying the new model, it is hoped that the model will be of interest to the wider Mars remote sensing community.

  3. Method for estimating modulation transfer function from sample images.

    Science.gov (United States)

    Saiga, Rino; Takeuchi, Akihisa; Uesugi, Kentaro; Terada, Yasuko; Suzuki, Yoshio; Mizutani, Ryuta

    2018-02-01

    The modulation transfer function (MTF) represents the frequency domain response of imaging modalities. Here, we report a method for estimating the MTF from sample images. Test images were generated from a number of images, including those taken with an electron microscope and with an observation satellite. These original images were convolved with point spread functions (PSFs) including those of circular apertures. The resultant test images were subjected to a Fourier transformation. The logarithm of the squared norm of the Fourier transform was plotted against the squared distance from the origin. Linear correlations were observed in the logarithmic plots, indicating that the PSF of the test images can be approximated with a Gaussian. The MTF was then calculated from the Gaussian-approximated PSF. The obtained MTF closely coincided with the MTF predicted from the original PSF. The MTF of an x-ray microtomographic section of a fly brain was also estimated with this method. The obtained MTF showed good agreement with the MTF determined from an edge profile of an aluminum test object. We suggest that this approach is an alternative way of estimating the MTF, independently of the image type. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

    Science.gov (United States)

    Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A

    2014-03-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method. Published by Elsevier B.V.

  5. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods

    Science.gov (United States)

    Coes, Alissa L.; Paretti, Nicholas V.; Foreman, William T.; Iverson, Jana L.; Alvarez, David A.

    2014-01-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19–23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.

  6. Failure Probability Calculation Method Using Kriging Metamodel-based Importance Sampling Method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seunggyu [Korea Aerospace Research Institue, Daejeon (Korea, Republic of); Kim, Jae Hoon [Chungnam Nat’l Univ., Daejeon (Korea, Republic of)

    2017-05-15

    The kernel density was determined based on sampling points obtained in a Markov chain simulation and was assumed to be an important sampling function. A Kriging metamodel was constructed in more detail in the vicinity of a limit state. The failure probability was calculated based on importance sampling, which was performed for the Kriging metamodel. A pre-existing method was modified to obtain more sampling points for a kernel density in the vicinity of a limit state. A stable numerical method was proposed to find a parameter of the kernel density. To assess the completeness of the Kriging metamodel, the possibility of changes in the calculated failure probability due to the uncertainty of the Kriging metamodel was calculated.

  7. Sequential sampling: a novel method in farm animal welfare assessment.

    Science.gov (United States)

    Heath, C A E; Main, D C J; Mullan, S; Haskell, M J; Browne, W J

    2016-02-01

    Lameness in dairy cows is an important welfare issue. As part of a welfare assessment, herd level lameness prevalence can be estimated from scoring a sample of animals, where higher levels of accuracy are associated with larger sample sizes. As the financial cost is related to the number of cows sampled, smaller samples are preferred. Sequential sampling schemes have been used for informing decision making in clinical trials. Sequential sampling involves taking samples in stages, where sampling can stop early depending on the estimated lameness prevalence. When welfare assessment is used for a pass/fail decision, a similar approach could be applied to reduce the overall sample size. The sampling schemes proposed here apply the principles of sequential sampling within a diagnostic testing framework. This study develops three sequential sampling schemes of increasing complexity to classify 80 fully assessed UK dairy farms, each with known lameness prevalence. Using the Welfare Quality herd-size-based sampling scheme, the first 'basic' scheme involves two sampling events. At the first sampling event half the Welfare Quality sample size is drawn, and then depending on the outcome, sampling either stops or is continued and the same number of animals is sampled again. In the second 'cautious' scheme, an adaptation is made to ensure that correctly classifying a farm as 'bad' is done with greater certainty. The third scheme is the only scheme to go beyond lameness as a binary measure and investigates the potential for increasing accuracy by incorporating the number of severely lame cows into the decision. The three schemes are evaluated with respect to accuracy and average sample size by running 100 000 simulations for each scheme, and a comparison is made with the fixed size Welfare Quality herd-size-based sampling scheme. All three schemes performed almost as well as the fixed size scheme but with much smaller average sample sizes. For the third scheme, an overall

  8. Effect on skin hydration of using baby wipes to clean the napkin area of newborn babies: assessor-blinded randomised controlled equivalence trial

    OpenAIRE

    Lavender, Tina; Furber, Christine; Campbell, Malcolm; Victor, Suresh; Roberts, Ian; Bedwell, Carol; Cork, Michael J

    2012-01-01

    Abstract Background Some national guidelines recommend the use of water alone for napkin cleansing. Yet, there is a readiness, amongst many parents, to use baby wipes. Evidence from randomised controlled trials, of the effect of baby wipes on newborn skin integrity is lacking. We conducted a study to examine the hypothesis that the use of a specifically formulated cleansing wipe on the napkin area of newborn infants (

  9. Interval estimation methods of the mean in small sample situation and the results' comparison

    International Nuclear Information System (INIS)

    Wu Changli; Guo Chunying; Jiang Meng; Lin Yuangen

    2009-01-01

    The methods of the sample mean's interval estimation, namely the classical method, the Bootstrap method, the Bayesian Bootstrap method, the Jackknife method and the spread method of the Empirical Characteristic distribution function are described. Numerical calculation on the samples' mean intervals is carried out where the numbers of the samples are 4, 5, 6 respectively. The results indicate the Bootstrap method and the Bayesian Bootstrap method are much more appropriate than others in small sample situation. (authors)

  10. Sampling in Qualitative Research: Rationale, Issues, and Methods

    OpenAIRE

    LUBORSKY, MARK R.; RUBINSTEIN, ROBERT L.

    1995-01-01

    In gerontology the most recognized and elaborate discourse about sampling is generally thought to be in quantitative research associated with survey research and medical research. But sampling has long been a central concern in the social and humanistic inquiry, albeit in a different guise suited to the different goals. There is a need for more explicit discussion of qualitative sampling issues. This article will outline the guiding principles and rationales, features, and practices of sampli...

  11. A comparison of four gravimetric fine particle sampling methods.

    Science.gov (United States)

    Yanosky, J D; MacIntosh, D L

    2001-06-01

    A study was conducted to compare four gravimetric methods of measuring fine particle (PM2.5) concentrations in air: the BGI, Inc. PQ200 Federal Reference Method PM2.5 (FRM) sampler; the Harvard-Marple Impactor (HI); the BGI, Inc. GK2.05 KTL Respirable/Thoracic Cyclone (KTL); and the AirMetrics MiniVol (MiniVol). Pairs of FRM, HI, and KTL samplers and one MiniVol sampler were collocated and 24-hr integrated PM2.5 samples were collected on 21 days from January 6 through April 9, 2000. The mean and standard deviation of PM2.5 levels from the FRM samplers were 13.6 and 6.8 microg/m3, respectively. Significant systematic bias was found between mean concentrations from the FRM and the MiniVol (1.14 microg/m3, p = 0.0007), the HI and the MiniVol (0.85 microg/m3, p = 0.0048), and the KTL and the MiniVol (1.23 microg/m3, p = 0.0078) according to paired t test analyses. Linear regression on all pairwise combinations of the sampler types was used to evaluate measurements made by the samplers. None of the regression intercepts was significantly different from 0, and only two of the regression slopes were significantly different from 1, that for the FRM and the MiniVol [beta1 = 0.91, 95% CI (0.83-0.99)] and that for the KTL and the MiniVol [beta1 = 0.88, 95% CI (0.78-0.98)]. Regression R2 terms were 0.96 or greater between all pairs of samplers, and regression root mean square error terms (RMSE) were 1.65 microg/m3 or less. These results suggest that the MiniVol will underestimate measurements made by the FRM, the HI, and the KTL by an amount proportional to PM2.5 concentration. Nonetheless, these results indicate that all of the sampler types are comparable if approximately 10% variation on the mean levels and on individual measurement levels is considered acceptable and the actual concentration is within the range of this study (5-35 microg/m3).

  12. On-line sample processing methods in flow analysis

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald

    2008-01-01

    In this chapter, the state of the art of flow injection and related approaches thereof for automation and miniaturization of sample processing regardless of the aggregate state of the sample medium is overviewed. The potential of the various generation of flow injection for implementation of in...

  13. Acoustically levitated droplets: a contactless sampling method for fluorescence studies.

    Science.gov (United States)

    Leiterer, Jork; Grabolle, Markus; Rurack, Knut; Resch-Genger, Ute; Ziegler, Jan; Nann, Thomas; Panne, Ulrich

    2008-01-01

    Acoustic levitation is used as a new tool to study concentration-dependent processes in fluorescence spectroscopy. With this technique, small amounts of liquid and solid samples can be measured without the need for sample supports or containers, which often limits signal acquisition and can even alter sample properties due to interactions with the support material. We demonstrate that, because of the small sample volume, fluorescence measurements at high concentrations of an organic dye are possible without the limitation of inner-filter effects, which hamper such experiments in conventional, cuvette-based measurements. Furthermore, we show that acoustic levitation of liquid samples provides an experimentally simple way to study distance-dependent fluorescence modulations in semiconductor nanocrystals. The evaporation of the solvent during levitation leads to a continuous increase of solute concentration and can easily be monitored by laser-induced fluorescence.

  14. Method for Hot Real-Time Sampling of Gasification Products

    Energy Technology Data Exchange (ETDEWEB)

    Pomeroy, Marc D [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-29

    The Thermochemical Process Development Unit (TCPDU) at the National Renewable Energy Laboratory (NREL) is a highly instrumented half-ton/day pilot scale plant capable of demonstrating industrially relevant thermochemical technologies from lignocellulosic biomass conversion, including gasification. Gasification creates primarily Syngas (a mixture of Hydrogen and Carbon Monoxide) that can be utilized with synthesis catalysts to form transportation fuels and other valuable chemicals. Biomass derived gasification products are a very complex mixture of chemical components that typically contain Sulfur and Nitrogen species that can act as catalysis poisons for tar reforming and synthesis catalysts. Real-time hot online sampling techniques, such as Molecular Beam Mass Spectrometry (MBMS), and Gas Chromatographs with Sulfur and Nitrogen specific detectors can provide real-time analysis providing operational indicators for performance. Sampling typically requires coated sampling lines to minimize trace sulfur interactions with steel surfaces. Other materials used inline have also shown conversion of sulfur species into new components and must be minimized. Sample line Residence time within the sampling lines must also be kept to a minimum to reduce further reaction chemistries. Solids from ash and char contribute to plugging and must be filtered at temperature. Experience at NREL has shown several key factors to consider when designing and installing an analytical sampling system for biomass gasification products. They include minimizing sampling distance, effective filtering as close to source as possible, proper line sizing, proper line materials or coatings, even heating of all components, minimizing pressure drops, and additional filtering or traps after pressure drops.

  15. A pilot study of the efficacy of wipes containing chlorhexidine 0.3%, climbazole 0.5% and Tris-EDTA to reduce Malassezia pachydermatis populations on canine skin

    Science.gov (United States)

    Cavana, Paola; Peano, Andrea; Petit, Jean-Yanique; Tizzani, Paolo; Perrot, Sébastien; Bensignor, Emmanuel; Guillot, Jacques

    2015-01-01

    Background Wipes containing chlorhexidine and azole derivates have been recommended for veterinary use. No study has been published about their activity against Malassezia pachydermatis. Hypothesis/Objectives To evaluate the in vivo and in vitro activity of wipes soaked in a chlorhexidine, climbazole and Tris-EDTA solution against Malassezia pachydermatis. Animals Five research colony shar-pei dogs. Methods Wipes were applied once daily onto the left axilla, left groin and perianal area (protocol A), and twice daily on the right axilla, right groin and umbilical region (protocol B) for 3 days. In vivo activity was evaluated by quantifying Malassezia colonies through contact plates on the selected body areas before and after wipe application. The activity of the solution in which the wipes were soaked was assessed in vitro by contact tests following the European Standard UNI EN 1275 guidelines. Results Samples collected after wipe application showed a significant and rapid reduction of Malassezia yeast CFU. No significant difference in the Malassezia reduction was found between protocols A and B. In vitro assay showed 100% activity against Malassezia yeasts after a 15 min contact time with the wipe solution. Conclusions and clinical importance Wipes containing chlorhexidine, climbazole and Tris-EDTA substantially reduced the M. pachydermatis population on the skin of dogs. The results, although this was an uncontrolled study performed on a small number of dogs, suggest that these wipes may be useful for topical therapy of Malassezia dermatitis involving the lips, paws, perianal area and skin folds. Résumé Contexte Des lingettes contenant de la chlorhexidine et des dérivésazolés ont été recommandés en médicine vétérinaire. Aucune étude n'a été publiée sur leur activité contre Malassezia pachydermatis. Hypothèses/Objectifs Evaluer l'activité in vivo et in vitro de lingettes imprégnées d'une solution de chlorhexidine, climbazole et Tris

  16. Reliability of a method of sampling stream invertebrates

    CSIR Research Space (South Africa)

    Chutter, FM

    1966-05-01

    Full Text Available In field ecological studies inferences must often be drawn from dissimilarities in numbers and species of organisms found in biological samples collected at different times and under various conditions....

  17. Summary Report for Evaluation of Compost Sample Drying Methods

    National Research Council Canada - National Science Library

    Frye, Russell

    1994-01-01

    .... Previous work in Support of these efforts developed a compost sample preparation scheme, consisting of air drying followed by milling, to reduce analytical variability in the heterogeneous compost matrix...

  18. Results of Testing the Relative Oxidizing Hazard of Wipes and KMI Zeolite

    Energy Technology Data Exchange (ETDEWEB)

    Ams, Bridget Elaine [Los Alamos National Laboratory

    2017-05-09

    This report includes the results from testing performed on the relative oxidizing hazard of a number of organic sorbing wipe materials, as well as KMI zeolite. These studies were undertaken to address a need by the Los Alamos National Laboratory (LANL) Hazardous Materials Management group, which requires a material that can sorb small spills in a glovebox without creating a disposal hazard due to the potential for oxidation reactions, as requested in Request for Testing of Wipes and Zeolite for Los Alamos National Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-002) and Request for Testing of Chamois Material for Los Alamos National Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-005). This set oftests is a continuation of previous testing described in Results from Preparation and Testing of Sorbents Mixed with (DWT-RPT-003), which provided data for the Waste Isolation Pilot Plant's Basis of Knowledge. The Basis of Knowledge establishes criteria for evaluating transuranic (TRU) waste that contains oxidizing chemicals.

  19. 40 CFR 761.312 - Compositing of samples.

    Science.gov (United States)

    2010-07-01

    ... to composite surface wipe test samples and to use the composite measurement to represent the PCB concentration of the entire surface. Composite samples consist of more than one sample gauze extracted and... arithmetic mean of the composited samples. (a) Compositing samples from surfaces to be used or reused. For...

  20. The effect of sample preparation methods on glass performance

    International Nuclear Information System (INIS)

    Oh, M.S.; Oversby, V.M.

    1990-01-01

    A series of experiments was conducted using SRL 165 synthetic waste glass to investigate the effects of surface preparation and leaching solution composition on the alteration of the glass. Samples of glass with as-cast surfaces produced smooth reaction layers and some evidence for precipitation of secondary phases from solution. Secondary phases were more abundant in samples reacted in deionized water than for those reacted in a silicate solution. Samples with saw-cut surfaces showed a large reduction in surface roughness after 7 days of reaction in either solution. Reaction in silicate solution for up to 91 days produced no further change in surface morphology, while reaction in DIW produced a spongy surface that formed the substrate for further surface layer development. The differences in the surface morphology of the samples may create microclimates that control the details of development of alteration layers on the glass; however, the concentrations of elements in leaching solutions show differences of 50% or less between samples prepared with different surface conditions for tests of a few months duration. 6 refs., 7 figs., 1 tab

  1. Statistical Methods and Tools for Hanford Staged Feed Tank Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Fountain, Matthew S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Brigantic, Robert T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Peterson, Reid A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-10-01

    This report summarizes work conducted by Pacific Northwest National Laboratory to technically evaluate the current approach to staged feed sampling of high-level waste (HLW) sludge to meet waste acceptance criteria (WAC) for transfer from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP). The current sampling and analysis approach is detailed in the document titled Initial Data Quality Objectives for WTP Feed Acceptance Criteria, 24590-WTP-RPT-MGT-11-014, Revision 0 (Arakali et al. 2011). The goal of this current work is to evaluate and provide recommendations to support a defensible, technical and statistical basis for the staged feed sampling approach that meets WAC data quality objectives (DQOs).

  2. Method for validating radiobiological samples using a linear accelerator

    International Nuclear Information System (INIS)

    Brengues, Muriel; Liu, David; Korn, Ronald; Zenhausern, Frederic

    2014-01-01

    There is an immediate need for rapid triage of the population in case of a large scale exposure to ionizing radiation. Knowing the dose absorbed by the body will allow clinicians to administer medical treatment for the best chance of recovery for the victim. In addition, today's radiotherapy treatment could benefit from additional information regarding the patient's sensitivity to radiation before starting the treatment. As of today, there is no system in place to respond to this demand. This paper will describe specific procedures to mimic the effects of human exposure to ionizing radiation creating the tools for optimization of administered radiation dosimetry for radiotherapy and/or to estimate the doses of radiation received accidentally during a radiation event that could pose a danger to the public. In order to obtain irradiated biological samples to study ionizing radiation absorbed by the body, we performed ex-vivo irradiation of human blood samples using the linear accelerator (LINAC). The LINAC was implemented and calibrated for irradiating human whole blood samples. To test the calibration, a 2 Gy test run was successfully performed on a tube filled with water with an accuracy of 3% in dose distribution. To validate our technique the blood samples were ex-vivo irradiated and the results were analyzed using a gene expression assay to follow the effect of the ionizing irradiation by characterizing dose responsive biomarkers from radiobiological assays. The response of 5 genes was monitored resulting in expression increase with the dose of radiation received. The blood samples treated with the LINAC can provide effective irradiated blood samples suitable for molecular profiling to validate radiobiological measurements via the gene-expression based biodosimetry tools. (orig.)

  3. Method for validating radiobiological samples using a linear accelerator.

    Science.gov (United States)

    Brengues, Muriel; Liu, David; Korn, Ronald; Zenhausern, Frederic

    2014-04-29

    There is an immediate need for rapid triage of the population in case of a large scale exposure to ionizing radiation. Knowing the dose absorbed by the body will allow clinicians to administer medical treatment for the best chance of recovery for the victim. In addition, today's radiotherapy treatment could benefit from additional information regarding the patient's sensitivity to radiation before starting the treatment. As of today, there is no system in place to respond to this demand. This paper will describe specific procedures to mimic the effects of human exposure to ionizing radiation creating the tools for optimization of administered radiation dosimetry for radiotherapy and/or to estimate the doses of radiation received accidentally during a radiation event that could pose a danger to the public. In order to obtain irradiated biological samples to study ionizing radiation absorbed by the body, we performed ex-vivo irradiation of human blood samples using the linear accelerator (LINAC). The LINAC was implemented and calibrated for irradiating human whole blood samples. To test the calibration, a 2 Gy test run was successfully performed on a tube filled with water with an accuracy of 3% in dose distribution. To validate our technique the blood samples were ex-vivo irradiated and the results were analyzed using a gene expression assay to follow the effect of the ionizing irradiation by characterizing dose responsive biomarkers from radiobiological assays. The response of 5 genes was monitored resulting in expression increase with the dose of radiation received. The blood samples treated with the LINAC can provide effective irradiated blood samples suitable for molecular profiling to validate radiobiological measurements via the gene-expression based biodosimetry tools.

  4. A One-Sample Test for Normality with Kernel Methods

    OpenAIRE

    Kellner , Jérémie; Celisse , Alain

    2015-01-01

    We propose a new one-sample test for normality in a Reproducing Kernel Hilbert Space (RKHS). Namely, we test the null-hypothesis of belonging to a given family of Gaussian distributions. Hence our procedure may be applied either to test data for normality or to test parameters (mean and covariance) if data are assumed Gaussian. Our test is based on the same principle as the MMD (Maximum Mean Discrepancy) which is usually used for two-sample tests such as homogeneity or independence testing. O...

  5. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR

    Science.gov (United States)

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample ...

  6. 40 CFR 80.8 - Sampling methods for gasoline and diesel fuel.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Sampling methods for gasoline and... PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES General Provisions § 80.8 Sampling methods for gasoline and diesel fuel. The sampling methods specified in this section shall be used to collect samples...

  7. Rapid methods for measuring radionuclides in food and environmental samples

    International Nuclear Information System (INIS)

    Perkins, Richard W.

    1995-01-01

    The application of ICP/mass spectrometry for the isotopic analysis of environmental samples, the use of drum assayers for measuring radionuclides in food and a rapid procedure for the measurement of the transuranic elements and thorium, performed at the Pacific Northwest Laboratory are discussed

  8. Modern methods of sample preparation for GC analysis

    NARCIS (Netherlands)

    de Koning, S.; Janssen, H.-G.; Brinkman, U.A.Th.

    2009-01-01

    Today, a wide variety of techniques is available for the preparation of (semi-) solid, liquid and gaseous samples, prior to their instrumental analysis by means of capillary gas chromatography (GC) or, increasingly, comprehensive two-dimensional GC (GC × GC). In the past two decades, a large number

  9. an assessment of methods for sampling carabid beetles

    African Journals Online (AJOL)

    Mgina

    collection of epigaeic (ground-dwelling) invertebrates (Southwood and Henderson,. 2000). It has been widely used for sampling carabid beetles in biodiversity inventories. (Niemela et al. 1994, Davies 2000, Nyundo. 2002), population and community ecology. (Greenslade 1968, Refseth, 1980,. Niemela1988, Niemela et al.

  10. Post-Decontamination Vapor Sampling and Analytical Test Methods

    Science.gov (United States)

    2015-08-12

    is decontaminated that could pose an exposure hazard to unprotected personnel. The chemical contaminants may include chemical warfare agents (CWAs... decontamination process. Chemical contaminants can include chemical warfare agents (CWAs) or their simulants, nontraditional agents (NTAs), toxic industrial...a range of test articles from coupons, panels, and small fielded equipment items. 15. SUBJECT TERMS Vapor hazard; vapor sampling; chemical warfare

  11. An Importance Sampling Simulation Method for Bayesian Decision Feedback Equalizers

    OpenAIRE

    Chen, S.; Hanzo, L.

    2000-01-01

    An importance sampling (IS) simulation technique is presented for evaluating the lower-bound bit error rate (BER) of the Bayesian decision feedback equalizer (DFE) under the assumption of correct decisions being fed back. A design procedure is developed, which chooses appropriate bias vectors for the simulation density to ensure asymptotic efficiency of the IS simulation.

  12. Vegetation Sampling for Wetland Delineation: A Review and Synthesis of Methods and Sampling Issues

    Science.gov (United States)

    2010-07-01

    which trees are sampled via use of an angle gauge or basal area prism (Husch et al. 2003; Packard and Radtke 2007). Basal area data can be used to...refuges from fungal pathogens for seeds of eastern hemlock (Tsuga canadensis). Ecology 85(1): 284– 289. Packard, K. C., and P. J. Radtke . 2007. Forest

  13. Method for Hot Real-Time Sampling of Pyrolysis Vapors

    Energy Technology Data Exchange (ETDEWEB)

    Pomeroy, Marc D [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-29

    Biomass Pyrolysis has been an increasing topic of research, in particular as a replacement for crude oil. This process utilizes moderate temperatures to thermally deconstruct the biomass which is then condensed into a mixture of liquid oxygenates to be used as fuel precursors. Pyrolysis oils contain more than 400 compounds, up to 60 percent of which do not re-volatilize for subsequent chemical analysis. Vapor chemical composition is also complicated as additional condensation reactions occur during the condensation and collection of the product. Due to the complexity of the pyrolysis oil, and a desire to catalytically upgrade the vapor composition before condensation, online real-time analytical techniques such as Molecular Beam Mass Spectrometry (MBMS) are of great use. However, in order to properly sample hot pyrolysis vapors, many challenges must be overcome. Sampling must occur within a narrow range of temperatures to reduce product composition changes from overheating or partial condensation or plugging of lines from condensed products. Residence times must be kept at a minimum to reduce further reaction chemistries. Pyrolysis vapors also form aerosols that are carried far downstream and can pass through filters resulting in build-up in downstream locations. The co-produced bio-char and ash from the pyrolysis process can lead to plugging of the sample lines, and must be filtered out at temperature, even with the use of cyclonic separators. A practical approach for considerations and sampling system design, as well as lessons learned are integrated into the hot analytical sampling system of the National Renewable Energy Laboratory's (NREL) Thermochemical Process Development Unit (TCPDU) to provide industrially relevant demonstrations of thermochemical transformations of biomass feedstocks at the pilot scale.

  14. Sampling pig farms at the abattoir in a cross-sectional study - Evaluation of a sampling method.

    Science.gov (United States)

    Birkegård, Anna Camilla; Halasa, Tariq; Toft, Nils

    2017-09-15

    A cross-sectional study design is relatively inexpensive, fast and easy to conduct when compared to other study designs. Careful planning is essential to obtaining a representative sample of the population, and the recommended approach is to use simple random sampling from an exhaustive list of units in the target population. This approach is rarely feasible in practice, and other sampling procedures must often be adopted. For example, when slaughter pigs are the target population, sampling the pigs on the slaughter line may be an alternative to on-site sampling at a list of farms. However, it is difficult to sample a large number of farms from an exact predefined list, due to the logistics and workflow of an abattoir. Therefore, it is necessary to have a systematic sampling procedure and to evaluate the obtained sample with respect to the study objective. We propose a method for 1) planning, 2) conducting, and 3) evaluating the representativeness and reproducibility of a cross-sectional study when simple random sampling is not possible. We used an example of a cross-sectional study with the aim of quantifying the association of antimicrobial resistance and antimicrobial consumption in Danish slaughter pigs. It was not possible to visit farms within the designated timeframe. Therefore, it was decided to use convenience sampling at the abattoir. Our approach was carried out in three steps: 1) planning: using data from meat inspection to plan at which abattoirs and how many farms to sample; 2) conducting: sampling was carried out at five abattoirs; 3) evaluation: representativeness was evaluated by comparing sampled and non-sampled farms, and the reproducibility of the study was assessed through simulated sampling based on meat inspection data from the period where the actual data collection was carried out. In the cross-sectional study samples were taken from 681 Danish pig farms, during five weeks from February to March 2015. The evaluation showed that the sampling

  15. Cyclophosphamide identification in wipe test by GC-MS and solid phase extraction Identificação de ciclofosfamida em wipe teste por CG-EM com prévia extração em fase sólida

    Directory of Open Access Journals (Sweden)

    Isarita Martins

    2004-03-01

    Full Text Available In this study cyclophosphamide was quantified after adapting a prior analytical method using gas chromatography-mass spectrometry after solid phase purification and derivatization with trifluoroacetic anhydride. The analyte was measured by analysis in wipe test from infusion bags, which may be contaminated by contact with the gloves used during preparation of the drugs. Surface of bag contaminated may be an important source of contamination for workers in the others chemoterapy handling areas, such as administration rooms. This drug, in fact, is one of the most frequently used alkylating antineoplastic agents for different types of tumors and it is furthermore classified as a human carcinogen by IARC. Ifosfamide was used as internal standard and the quantification was carried out by reference to calibration curves within a range from 1 to 100 ng/mL. The limit of detection was 0.4 ng/mL. The values of the variation coefficient varied from 0.5 to 10% (intra-assay and from 0 to 19% (interassay. Frozen reference wipe samples containing cyclophosphamide were analysed over one month and no significant loss was observed. The range obtained for bias assay was 83-116% and the recovery was 98.9%. Cyclophosphamide was measured in 36 of 42 infusion bags collected from different hospitals with values ranging from 90 to 41874 ng (median= 607.5 ng. The results, well related to those reported in the literature, suggest that this method can be used to identify cyclophosphamide from wipe samples and can be considered useful in exposure assessment to this drug.A ciclofosfamida é uma agente alquilante freqüentemente utilizado na prática clínica para diferentes tipos de tumores e, é classificado como carcinógeno para humanos pelo IARC. Neste estudo, o fármaco foi quantificado, após adaptação de um método analítico, utilizando a cromatografia gasosa acoplada à espectrometria de massa com prévia extração em fase sólida e derivação com anidrido

  16. Method for spiking soil samples with organic compounds

    DEFF Research Database (Denmark)

    Brinch, Ulla C; Ekelund, Flemming; Jacobsen, Carsten S

    2002-01-01

    We examined the harmful side effects on indigenous soil microorganisms of two organic solvents, acetone and dichloromethane, that are normally used for spiking of soil with polycyclic aromatic hydrocarbons for experimental purposes. The solvents were applied in two contamination protocols to either...... higher than in control soil, probably due mainly to release of predation from indigenous protozoa. In order to minimize solvent effects on indigenous soil microorganisms when spiking native soil samples with compounds having a low water solubility, we propose a common protocol in which the contaminant...... tagged with luxAB::Tn5. For both solvents, application to the whole sample resulted in severe side effects on both indigenous protozoa and bacteria. Application of dichloromethane to the whole soil volume immediately reduced the number of protozoa to below the detection limit. In one of the soils...

  17. Exploring biomolecular dynamics and interactions using advanced sampling methods

    International Nuclear Information System (INIS)

    Luitz, Manuel; Bomblies, Rainer; Ostermeir, Katja; Zacharias, Martin

    2015-01-01

    Molecular dynamics (MD) and Monte Carlo (MC) simulations have emerged as a valuable tool to investigate statistical mechanics and kinetics of biomolecules and synthetic soft matter materials. However, major limitations for routine applications are due to the accuracy of the molecular mechanics force field and due to the maximum simulation time that can be achieved in current simulations studies. For improving the sampling a number of advanced sampling approaches have been designed in recent years. In particular, variants of the parallel tempering replica-exchange methodology are widely used in many simulation studies. Recent methodological advancements and a discussion of specific aims and advantages are given. This includes improved free energy simulation approaches and conformational search applications. (topical review)

  18. Sample preparation method for induced mutation on orchid

    International Nuclear Information System (INIS)

    Suhaimi Musa; Sakinah Ariffin

    2005-01-01

    Studies on the induction of mutation in Dendrobium orchid at MINT has produced a number of new orchid mutant cultivars. Tissue culture techniques on orchid seeds and meristem cloning are employed in preparing the samples for the mutation induction. Solid medium based on the Murashige and Skoog (1962) and liquid medium based on Vacin and Went (1949) were found to be suitable in producing protocorm like bodies (PLBs) that are required for the irradiation treatment. (Author)

  19. Sample Size Calculations for Population Size Estimation Studies Using Multiplier Methods With Respondent-Driven Sampling Surveys.

    Science.gov (United States)

    Fearon, Elizabeth; Chabata, Sungai T; Thompson, Jennifer A; Cowan, Frances M; Hargreaves, James R

    2017-09-14

    While guidance exists for obtaining population size estimates using multiplier methods with respondent-driven sampling surveys, we lack specific guidance for making sample size decisions. To guide the design of multiplier method population size estimation studies using respondent-driven sampling surveys to reduce the random error around the estimate obtained. The population size estimate is obtained by dividing the number of individuals receiving a service or the number of unique objects distributed (M) by the proportion of individuals in a representative survey who report receipt of the service or object (P). We have developed an approach to sample size calculation, interpreting methods to estimate the variance around estimates obtained using multiplier methods in conjunction with research into design effects and respondent-driven sampling. We describe an application to estimate the number of female sex workers in Harare, Zimbabwe. There is high variance in estimates. Random error around the size estimate reflects uncertainty from M and P, particularly when the estimate of P in the respondent-driven sampling survey is low. As expected, sample size requirements are higher when the design effect of the survey is assumed to be greater. We suggest a method for investigating the effects of sample size on the precision of a population size estimate obtained using multipler methods and respondent-driven sampling. Uncertainty in the size estimate is high, particularly when P is small, so balancing against other potential sources of bias, we advise researchers to consider longer service attendance reference periods and to distribute more unique objects, which is likely to result in a higher estimate of P in the respondent-driven sampling survey. ©Elizabeth Fearon, Sungai T Chabata, Jennifer A Thompson, Frances M Cowan, James R Hargreaves. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 14.09.2017.

  20. Improvement of correlated sampling Monte Carlo methods for reactivity calculations

    International Nuclear Information System (INIS)

    Nakagawa, Masayuki; Asaoka, Takumi

    1978-01-01

    Two correlated Monte Carlo methods, the similar flight path and the identical flight path methods, have been improved to evaluate up to the second order change of the reactivity perturbation. Secondary fission neutrons produced by neutrons having passed through perturbed regions in both unperturbed and perturbed systems are followed in a way to have a strong correlation between secondary neutrons in both the systems. These techniques are incorporated into the general purpose Monte Carlo code MORSE, so as to be able to estimate also the statistical error of the calculated reactivity change. The control rod worths measured in the FCA V-3 assembly are analyzed with the present techniques, which are shown to predict the measured values within the standard deviations. The identical flight path method has revealed itself more useful than the similar flight path method for the analysis of the control rod worth. (auth.)

  1. Summary Report for Evaluation of Compost Sample Drying Methods

    National Research Council Canada - National Science Library

    Frye, Russell

    1994-01-01

    The U.S. Army Environmental Center (USAEC), formerly the U.S. Army Toxic and Hazardous Materials Agency, has evaluated composting methods for treatment of explosive-contaminated soils and sediments at Army installations...

  2. The method of Sample Management in Neutron Activation Analysis Laboratory-Serpong

    International Nuclear Information System (INIS)

    Elisabeth-Ratnawati

    2005-01-01

    In the testing laboratory used by neutron activation analysis method, sample preparation is the main factor and it can't be neglect. The error in the sample preparation can give result with lower accuracy. In this article is explained the scheme of sample preparation i.e sample receive administration, the separate of sample, fluid and solid sample preparation, sample grouping, irradiation, sample counting and holding the sample post irradiation. If the management of samples were good application based on Standard Operation Procedure, therefore each samples has good traceability. To optimize the management of samples is needed the trained and skilled personal and good facility. (author)

  3. Two methods of self-sampling compared to clinician sampling to detect reproductive tract infections in Gugulethu, South Africa

    NARCIS (Netherlands)

    van de Wijgert, Janneke; Altini, Lydia; Jones, Heidi; de Kock, Alana; Young, Taryn; Williamson, Anna-Lise; Hoosen, Anwar; Coetzee, Nicol

    2006-01-01

    To assess the validity, feasibility, and acceptability of 2 methods of self-sampling compared to clinician sampling during a speculum examination. To improve screening for reproductive tract infections (RTIs) in resource-poor settings. In a public clinic in Cape Town, 450 women underwent a speculum

  4. Genetic analysis of bulimia nervosa: methods and sample description.

    Science.gov (United States)

    Kaye, Walter H; Devlin, Bernie; Barbarich, Nicole; Bulik, Cynthia M; Thornton, Laura; Bacanu, Silviu-Alin; Fichter, Manfred M; Halmi, Katherine A; Kaplan, Allan S; Strober, Michael; Woodside, D Blake; Bergen, Andrew W; Crow, Scott; Mitchell, James; Rotondo, Alessandro; Mauri, Mauro; Cassano, Giovanni; Keel, Pamela; Plotnicov, Katherine; Pollice, Christine; Klump, Kelly L; Lilenfeld, Lisa R; Ganjei, J Kelly; Quadflieg, Norbert; Berrettini, Wade H

    2004-05-01

    Twin and family studies suggest that genetic variants contribute to the pathogenesis of bulimia nervosa (BN) and anorexia nervosa (AN). The Price Foundation has supported an international, multisite study of families with these disorders to identify these genetic variations. The current study presents the clinical characteristics of this sample as well as a description of the study methodology. All probands met modified criteria for BN or bulimia nervosa with a history of AN (BAN) as defined in the 4th ed. of the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV; American Psychiatric Association, 1994). All affected relatives met DSM-IV criteria for BN, AN, BAN, or eating disorders not otherwise specified (EDNOS). Probands and affected relatives were assessed diagnostically using both trained-rater and self-report assessments. DNA samples were collected from probands, affected relatives, and available biologic parents. Assessments were obtained from 163 BN probands and 165 BAN probands. Overall, there were 365 relative pairs available for linkage analysis. Of the affected relatives of BN probands, 62 were diagnosed as BN (34.8%), 49 as BAN (27.5%), 35 as AN (19.7%), and 32 as EDNOS (18.0%). For the relatives of BAN probands, 42 were diagnosed as BN (22.5%), 67 as BAN (35.8%), 48 as AN (25.7%), and 30 as EDNOS (16.0%). This study represents the largest genetic study of eating disorders to date. Clinical data indicate that although there are a large number of individuals with BN disorders, a range of eating pathology is represented in the sample, allowing for the examination of several different phenotypes in molecular genetic analyses. Copyright 2004 by Wiley Periodicals, Inc. Int J Eat Disord 35: 556-570, 2004.

  5. Designing waveforms for temporal encoding using a frequency sampling method

    DEFF Research Database (Denmark)

    Gran, Fredrik; Jensen, Jørgen Arendt

    2007-01-01

    was compared to a linear frequency modulated signal with amplitude tapering, previously used in clinical studies for synthetic transmit aperture imaging. The latter had a relatively flat spectrum which implied that the waveform tried to excite all frequencies including ones with low amplification. The proposed......In this paper a method for designing waveforms for temporal encoding in medical ultrasound imaging is described. The method is based on least squares optimization and is used to design nonlinear frequency modulated signals for synthetic transmit aperture imaging. By using the proposed design method...... waveform, on the other hand, was designed so that only frequencies where the transducer had a large amplification were excited. Hereby, unnecessary heating of the transducer could be avoided and the signal-tonoise ratio could be increased. The experimental ultrasound scanner RASMUS was used to evaluate...

  6. A destructive sample preparation method for radioactive waste characterization

    International Nuclear Information System (INIS)

    Olteanu, M.; Bucur, C.

    2015-01-01

    Acid digestion, using the microwave power, was applied for ''dissolution'' of different materials corresponding to the radioactive waste matrices resulted from a nuclear power plant operation, including exchange resin (cationic and mixed), concrete, paper, textile and activated charcoals. A small aliquot of solid sample (0.1-0.5g) was mixed with a known volume of digestion reagents (HNO3 67% - H2O2 30% or HNO3 67% - HCl 37%, with HF addition if the SiO2 was present in matrices) in a 100 ml PTFE vessel and it was mineralized using a Berghof digestion system, Speedwave 4. Starting from the manufacturer procedures, the technical parameters (temperature and mineralization time), the types and quantities of digestion reagents were optimized. After the mineralization process, the samples were transferred in centrifuge tubes, separated at 3500 rot/min and visually analysed. The obtained solutions were clear, without suspended or deposed materials and separated phases, ready for future separation processes of the ''difficult to measure'' radioisotopes. (authors)

  7. COMPARISON OF LARGE RIVER SAMPLING METHODS ON ALGAL METRICS

    Science.gov (United States)

    We compared the results of four methods used to assess the algal communities at 60 sites distributed among four rivers. Based on Principle Component Analysis of physical habitat data collected concomitantly with the algal data, sites were separated into those with a mean thalweg...

  8. COMPARISON OF LARGE RIVER SAMPLING METHOD USING DIATOM METRICS

    Science.gov (United States)

    We compared the results of four methods used to assess the algal communities at 60 sites distributed among four rivers. Based on Principle Component Analysis of physical habitat data collected concomitantly with the algal data, sites were separated into those with a mean thalweg...

  9. Multiple histogram method and static Monte Carlo sampling

    NARCIS (Netherlands)

    Inda, M.A.; Frenkel, D.

    2004-01-01

    We describe an approach to use multiple-histogram methods in combination with static, biased Monte Carlo simulations. To illustrate this, we computed the force-extension curve of an athermal polymer from multiple histograms constructed in a series of static Rosenbluth Monte Carlo simulations. From

  10. Sample preparation method for ICP-MS measurement of 99Tc in a large amount of environmental samples

    International Nuclear Information System (INIS)

    Kondo, M.; Seki, R.

    2002-01-01

    Sample preparation for measurement of 99 Tc in a large amount of soil and water samples by ICP-MS has been developed using 95m Tc as a yield tracer. This method is based on the conventional method for a small amount of soil samples using incineration, acid digestion, extraction chromatography (TEVA resin) and ICP-MS measurement. Preliminary concentration of Tc has been introduced by co-precipitation with ferric oxide. The matrix materials in a large amount of samples were more sufficiently removed with keeping the high recovery of Tc than previous method. The recovery of Tc was 70-80% for 100 g soil samples and 60-70% for 500 g of soil and 500 L of water samples. The detection limit of this method was evaluated as 0.054 mBq/kg in 500 g soil and 0.032 μBq/L in 500 L water. The determined value of 99 Tc in the IAEA-375 (soil sample collected near the Chernobyl Nuclear Reactor) was 0.25 ± 0.02 Bq/kg. (author)

  11. Solid phase microextraction headspace sampling of chemical warfare agent contaminated samples : method development for GC-MS analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jackson Lepage, C.R.; Hancock, J.R. [Defence Research and Development Canada, Medicine Hat, AB (Canada); Wyatt, H.D.M. [Regina Univ., SK (Canada)

    2004-07-01

    Defence R and D Canada-Suffield (DRDC-Suffield) is responsible for analyzing samples that are suspected to contain chemical warfare agents, either collected by the Canadian Forces or by first-responders in the event of a terrorist attack in Canada. The analytical techniques used to identify the composition of the samples include gas chromatography-mass spectrometry (GC-MS), liquid chromatography-mass spectrometry (LC-MS), Fourier-transform infrared spectroscopy (FT-IR) and nuclear magnetic resonance spectroscopy. GC-MS and LC-MS generally require solvent extraction and reconcentration, thereby increasing sample handling. The authors examined analytical techniques which reduce or eliminate sample manipulation. In particular, this paper presented a screening method based on solid phase microextraction (SPME) headspace sampling and GC-MS analysis for chemical warfare agents such as mustard, sarin, soman, and cyclohexyl methylphosphonofluoridate in contaminated soil samples. SPME is a method which uses small adsorbent polymer coated silica fibers that trap vaporous or liquid analytes for GC or LC analysis. Collection efficiency can be increased by adjusting sampling time and temperature. This method was tested on two real-world samples, one from excavated chemical munitions and the second from a caustic decontamination mixture. 7 refs., 2 tabs., 3 figs.

  12. The study of combining Latin Hypercube Sampling method and LU decomposition method (LULHS method) for constructing spatial random field

    Science.gov (United States)

    WANG, P. T.

    2015-12-01

    Groundwater modeling requires to assign hydrogeological properties to every numerical grid. Due to the lack of detailed information and the inherent spatial heterogeneity, geological properties can be treated as random variables. Hydrogeological property is assumed to be a multivariate distribution with spatial correlations. By sampling random numbers from a given statistical distribution and assigning a value to each grid, a random field for modeling can be completed. Therefore, statistics sampling plays an important role in the efficiency of modeling procedure. Latin Hypercube Sampling (LHS) is a stratified random sampling procedure that provides an efficient way to sample variables from their multivariate distributions. This study combines the the stratified random procedure from LHS and the simulation by using LU decomposition to form LULHS. Both conditional and unconditional simulations of LULHS were develpoed. The simulation efficiency and spatial correlation of LULHS are compared to the other three different simulation methods. The results show that for the conditional simulation and unconditional simulation, LULHS method is more efficient in terms of computational effort. Less realizations are required to achieve the required statistical accuracy and spatial correlation.

  13. Potential Allergens in Disposable Diaper Wipes, Topical Diaper Preparations, and Disposable Diapers: Under-recognized Etiology of Pediatric Perineal Dermatitis.

    Science.gov (United States)

    Yu, JiaDe; Treat, James; Chaney, Keri; Brod, Bruce

    2016-01-01

    Allergic contact dermatitis in young children may be an under-recognized cause of perineal dermatitis. The diapered infant skin is uniquely susceptible to allergic contact dermatitis because of more permeable neonatal skin, a moist environment, frequent contact with irritants and resultant skin barrier breakdown, and exposure to topical products such as diaper wipes, diaper preparations, and disposable diapers. To our knowledge, potential allergens in these products have not been thoroughly catalogued or studied. We explore and review potential allergenic ingredients in diaper wipes, topical diaper preparations, and disposable diapers. We analyzed 63 diaper wipes, 41 topical diaper preparations, and the 3 top selling diaper brands available from two of the largest retailers in the United States. Each potential allergen is discussed, and epidemiologic studies of rates of sensitization to potential allergens in children are also reported. Botanical extracts, including members of the Compositae family, were the most commonly represented potential allergen in both diaper wipes and topical preparations. Other potential allergens identified with high frequency include α-tocopherol, fragrances, propylene glycol, parabens, iodopropynyl butylcarbamate, and lanolin. Frequent culprits such as formaldehyde releasers and methylchloroisothiazolinone/methylisothiazolinone were not prevalent in our analyzed products.

  14. Experimental estimation of migration and transfer of organic substances from consumer articles to cotton wipes: Evaluation of underlying mechanisms

    NARCIS (Netherlands)

    Clausen, P.A.; Spaan, S.; Brouwer, D.H.; Marquart, H.; Feber, M. le; Engel, R.; Geerts, L.; Jensen, K.A.; Kofoed-Sørensen, V.; Hansen, B.; Brouwere, K. de

    2016-01-01

    The aim of this work was to identify the key mechanisms governing transport of organic chemical substances from consumer articles to cotton wipes. The results were used to establish a mechanistic model to improve assessment of dermal contact exposure. Four types of PVC flooring, 10 types of textiles

  15. High-throughput liquid-absorption preconcentrator sampling methods

    Science.gov (United States)

    Zaromb, Solomon

    1994-01-01

    A system for detecting trace concentrations of an analyte in air includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container comprising a wettable material. The wettable material is continuously wetted with an analyte-sorbing liquid which flows from one part of the container to a lower end. Sampled air flows through the container in contact with the wetted material with a swirling motion which results in efficient transfer of analyte vapors or aerosol particles to the sorbing liquid and preconcentration of traces of analyte in the liquid. The preconcentrated traces of analyte may be either detected within the container or removed therefrom for injection into a separate detection means or for subsequent analysis.

  16. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    International Nuclear Information System (INIS)

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy's (DOE's) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples

  17. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy`s (DOE`s) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples.

  18. Detecting spatial structures in throughfall data: The effect of extent, sample size, sampling design, and variogram estimation method

    Science.gov (United States)

    Voss, Sebastian; Zimmermann, Beate; Zimmermann, Alexander

    2016-09-01

    In the last decades, an increasing number of studies analyzed spatial patterns in throughfall by means of variograms. The estimation of the variogram from sample data requires an appropriate sampling scheme: most importantly, a large sample and a layout of sampling locations that often has to serve both variogram estimation and geostatistical prediction. While some recommendations on these aspects exist, they focus on Gaussian data and high ratios of the variogram range to the extent of the study area. However, many hydrological data, and throughfall data in particular, do not follow a Gaussian distribution. In this study, we examined the effect of extent, sample size, sampling design, and calculation method on variogram estimation of throughfall data. For our investigation, we first generated non-Gaussian random fields based on throughfall data with large outliers. Subsequently, we sampled the fields with three extents (plots with edge lengths of 25 m, 50 m, and 100 m), four common sampling designs (two grid-based layouts, transect and random sampling) and five sample sizes (50, 100, 150, 200, 400). We then estimated the variogram parameters by method-of-moments (non-robust and robust estimators) and residual maximum likelihood. Our key findings are threefold. First, the choice of the extent has a substantial influence on the estimation of the variogram. A comparatively small ratio of the extent to the correlation length is beneficial for variogram estimation. Second, a combination of a minimum sample size of 150, a design that ensures the sampling of small distances and variogram estimation by residual maximum likelihood offers a good compromise between accuracy and efficiency. Third, studies relying on method-of-moments based variogram estimation may have to employ at least 200 sampling points for reliable variogram estimates. These suggested sample sizes exceed the number recommended by studies dealing with Gaussian data by up to 100 %. Given that most previous

  19. Random sampling of quantum states: a survey of methods and some issues regarding the Overparametrized Method

    International Nuclear Information System (INIS)

    Maziero, Jonas

    2015-01-01

    The numerical generation of random quantum states (RQS) is an important procedure for investigations in quantum information science. Here, we review some methods that may be used for performing that task. We start by presenting a simple procedure for generating random state vectors, for which the main tool is the random sampling of unbiased discrete probability distributions (DPD). Afterwards, the creation of random density matrices is addressed. In this context, we first present the standard method, which consists in using the spectral decomposition of a quantum state for getting RQS from random DPDs and random unitary matrices. In the sequence, the Bloch vector parametrization method is described. This approach, despite being useful in several instances, is not in general convenient for RQS generation. In the last part of the article, we regard the overparametrized method (OPM) and the related Ginibre and Bures techniques. The OPM can be used to create random positive semidefinite matrices with unit trace from randomly produced general complex matrices in a simple way that is friendly for numerical implementations. We consider a physically relevant issue related to the possible domains that may be used for the real and imaginary parts of the elements of such general complex matrices. Subsequently, a too fast concentration of measure in the quantum state space that appears in this parametrization is noticed. (author)

  20. Concentration of Melton Valley Storage Tank surrogates with a wiped film evaporator

    International Nuclear Information System (INIS)

    Boring, M.D.; Farr, L.L.; Fowler, V.L.; Hewitt, J.D.

    1994-08-01

    This report describes experiments to determine whether a wiped film evaporator (WFE) might be used to concentrate low-level liquid radioactive waste (LLLW). Solutions used in these studies were surrogates that contain no radionuclides. The compositions of the surrogates were based on one of Oak Ridge National Laboratory's (ORNL's) Melton Valley Storage Tanks (MVSTs). It was found that a WFE could be used to concentrate LLLW to varying degrees by manipulating various parameters. The parameters studied were rotor speed, process fluid feed temperature and feed rate, and evaporator temperature. Product consistency varied from an unsaturated liquid to a dry powder. Volume reductions up to 68% were achieved. System decontamination factors were consistently in the range of 10 4

  1. Performance of a wiped film evaporator with simulated high level waste slurries

    International Nuclear Information System (INIS)

    Dierks, R.D.; Bonner, W.F.

    1975-01-01

    The horizontal, reverse taper, wiped film evaporator that was evaluated demonstrated a number of positive characteristics with respect to its applicability in the solidification of nuclear fuel recovery process wastes. Foremost among these is its ability to remove the bulk (80 to 90 percent) of the liquid associated with any of the purex-type high level, intermediate level, or mixed waste slurries. The major disadvantage of the evaporator is its current inability to discharge a product that is low enough in liquid content to avoid sticking to the evaporator discharge nozzle. Also, while the indirect indications of the torque required to turn the rotor and the power drawn by the drive motor are indicative of the liquid content of the discharged product, no reliable correlation has been found to cover all of the possible flow rates and feed stock compositions that the evaporator may be required to handle. In addition, no reliable means has been found to indicate the presence or absence of product flow through the discharge nozzle. The lack of a positive means of moving the product concentrate out of the evaporator and into a high temperature receiver is an undesirable feature of the evaporator. Pulverized glass former, or frit, was added to the evaporator feedstock in a ratio of frit to metal oxides of 2 to 1, and the resulting mixture successfully evaporated to a concentrate containing about 50 percent solids. In general, the performance of the wiped film evaporator evaluated was favorable for its use in a nuclear waste fixation process, however further development of the rotor design, power input, and operating techniques will be required to produce a free flowing solid product

  2. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  3. 7 CFR 51.308 - Methods of sampling and calculation of percentages.

    Science.gov (United States)

    2010-01-01

    ..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Methods of Sampling and Calculation of Percentages § 51.308 Methods of sampling and calculation of percentages. (a) When the numerical... 7 Agriculture 2 2010-01-01 2010-01-01 false Methods of sampling and calculation of percentages. 51...

  4. Effect of sample preparation methods on photometric determination of the tellurium and cobalt content in the samples of copper concentrates

    Directory of Open Access Journals (Sweden)

    Viktoriya Butenko

    2016-03-01

    Full Text Available Methods of determination of cobalt and nickel in copper concentrates currently used in factory laboratories are very labor intensive and time consuming. The limiting stage of the analysis is preliminary chemical sample preparation. Carrying out the decomposition process of industrial samples with concentrated mineral acids in open systems does not allow to improve the metrological characteristics of the methods, for this reason improvement the methods of sample preparation is quite relevant and has a practical interest. The work was dedicated to the determination of the optimal conditions of preliminary chemical preparation of copper concentrate samples for the subsequent determination of cobalt and tellurium in the obtained solution using tellurium-spectrophotometric method. Decomposition of the samples was carried out by acid dissolving in individual mineral acids and their mixtures by heating in an open system as well as by using ultrasonification and microwave radiation in a closed system. In order to select the optimal conditions for the decomposition of the samples in a closed system the phase contact time and ultrasonic generator’s power were varied. Intensification of the processes of decomposition of copper concentrates with nitric acid (1:1, ultrasound and microwave radiation allowed to transfer quantitatively cobalt and tellurium into solution spending 20 and 30 min respectively. This reduced the amount of reactants used and improved the accuracy of determination by running the process in strictly identical conditions.

  5. Sparsity-weighted outlier FLOODing (OFLOOD) method: Efficient rare event sampling method using sparsity of distribution.

    Science.gov (United States)

    Harada, Ryuhei; Nakamura, Tomotake; Shigeta, Yasuteru

    2016-03-30

    As an extension of the Outlier FLOODing (OFLOOD) method [Harada et al., J. Comput. Chem. 2015, 36, 763], the sparsity of the outliers defined by a hierarchical clustering algorithm, FlexDice, was considered to achieve an efficient conformational search as sparsity-weighted "OFLOOD." In OFLOOD, FlexDice detects areas of sparse distribution as outliers. The outliers are regarded as candidates that have high potential to promote conformational transitions and are employed as initial structures for conformational resampling by restarting molecular dynamics simulations. When detecting outliers, FlexDice defines a rank in the hierarchy for each outlier, which relates to sparsity in the distribution. In this study, we define a lower rank (first ranked), a medium rank (second ranked), and the highest rank (third ranked) outliers, respectively. For instance, the first-ranked outliers are located in a given conformational space away from the clusters (highly sparse distribution), whereas those with the third-ranked outliers are nearby the clusters (a moderately sparse distribution). To achieve the conformational search efficiently, resampling from the outliers with a given rank is performed. As demonstrations, this method was applied to several model systems: Alanine dipeptide, Met-enkephalin, Trp-cage, T4 lysozyme, and glutamine binding protein. In each demonstration, the present method successfully reproduced transitions among metastable states. In particular, the first-ranked OFLOOD highly accelerated the exploration of conformational space by expanding the edges. In contrast, the third-ranked OFLOOD reproduced local transitions among neighboring metastable states intensively. For quantitatively evaluations of sampled snapshots, free energy calculations were performed with a combination of umbrella samplings, providing rigorous landscapes of the biomolecules. © 2015 Wiley Periodicals, Inc.

  6. Comparing Microbiome Sampling Methods in a Wild Mammal: Fecal and Intestinal Samples Record Different Signals of Host Ecology, Evolution.

    Science.gov (United States)

    Ingala, Melissa R; Simmons, Nancy B; Wultsch, Claudia; Krampis, Konstantinos; Speer, Kelly A; Perkins, Susan L

    2018-01-01

    The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces) and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated.

  7. Comparing Microbiome Sampling Methods in a Wild Mammal: Fecal and Intestinal Samples Record Different Signals of Host Ecology, Evolution

    Directory of Open Access Journals (Sweden)

    Melissa R. Ingala

    2018-05-01

    Full Text Available The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated.

  8. Perilymph sampling from the cochlear apex: a reliable method to obtain higher purity perilymph samples from scala tympani.

    Science.gov (United States)

    Salt, Alec N; Hale, Shane A; Plonkte, Stefan K R

    2006-05-15

    Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2microL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The

  9. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality

    Science.gov (United States)

    Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne

    2018-01-01

    Introduction Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. Materials and methods The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. Results The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. Conclusions The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in

  10. DESI-MS2: a rapid and innovative method for trace analysis of six cytostatic drugs in health care setting.

    Science.gov (United States)

    Fabrizi, Giovanni; Fioretti, Marzia; Rocca, Lucia Mainero; Curini, Roberta

    2012-05-01

    With the aim of establishing exposure levels for hospital personnel preparing and administering cytostatic drugs (CDs), here, we present an innovative screening method based on the use of the desorption electrospray ionization (DESI) interface coupled with a hybrid quadrupole linear ion trap mass spectrometer. A rapid, simple, and sensitive procedure was developed for the simultaneous surface monitoring of cyclophosphamide, dacarbazine, methotrexate, vincristine, gemcitabine, and cytarabine. Since analytes were in the solid state, a novel approach based on the use of passive samplers was combined with the direct analysis of wipes. A PTFE-printed glass slide was used as a passive sampler, while hydrophobic centers of Swiffer® cloths were judged extremely efficient as wipe samplers. After the sampling period, the CD collectors were directly processed with the DESI-MS system without any further treatment. MS/MS confirmatory analysis was conducted using selected reaction monitoring in the positive ion mode and detection limits were evaluated. Values were at the picograms per square millimeter levels on the passive collector and at the picograms per square centimeter levels for the wipe ones. Direct determination on solid-state samples combined with mass spectrometry selectivity provided a powerful tool so far unapplied to occupational hygiene.

  11. Surveying immigrants without sampling frames - evaluating the success of alternative field methods.

    Science.gov (United States)

    Reichel, David; Morales, Laura

    2017-01-01

    This paper evaluates the sampling methods of an international survey, the Immigrant Citizens Survey, which aimed at surveying immigrants from outside the European Union (EU) in 15 cities in seven EU countries. In five countries, no sample frame was available for the target population. Consequently, alternative ways to obtain a representative sample had to be found. In three countries 'location sampling' was employed, while in two countries traditional methods were used with adaptations to reach the target population. The paper assesses the main methodological challenges of carrying out a survey among a group of immigrants for whom no sampling frame exists. The samples of the survey in these five countries are compared to results of official statistics in order to assess the accuracy of the samples obtained through the different sampling methods. It can be shown that alternative sampling methods can provide meaningful results in terms of core demographic characteristics although some estimates differ to some extent from the census results.

  12. Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hong-geller, Elizabeth [Los Alamos National Laboratory; Valdez, Yolanda E [Los Alamos National Laboratory; Shou, Yulin [Los Alamos National Laboratory; Yoshida, Thomas M [Los Alamos National Laboratory; Marrone, Babetta L [Los Alamos National Laboratory; Dunbar, John [Los Alamos National Laboratory

    2009-01-01

    Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.

  13. A Sequential Optimization Sampling Method for Metamodels with Radial Basis Functions

    Science.gov (United States)

    Pan, Guang; Ye, Pengcheng; Yang, Zhidong

    2014-01-01

    Metamodels have been widely used in engineering design to facilitate analysis and optimization of complex systems that involve computationally expensive simulation programs. The accuracy of metamodels is strongly affected by the sampling methods. In this paper, a new sequential optimization sampling method is proposed. Based on the new sampling method, metamodels can be constructed repeatedly through the addition of sampling points, namely, extrema points of metamodels and minimum points of density function. Afterwards, the more accurate metamodels would be constructed by the procedure above. The validity and effectiveness of proposed sampling method are examined by studying typical numerical examples. PMID:25133206

  14. Sampling methods. A survey of methods in use in the Nordic countries

    International Nuclear Information System (INIS)

    Isaksson, M.

    2000-10-01

    This report is a survey of sampling techniques currently in use for radioactivity measurements in the Nordic countries, but restricted to sampling techniques for pasture, soil and deposition in emergency situations. It is found that the participating laboratories apply similar sampling procedures for pasture, including cutting height and size of sampled areas. Soil samples are generally taken by some sort of corer of different diameter. The number of cores taken varies, different sampling patterns are used, and pooling of the samples is done by some of the laboratories. The analysis of pasture and of soil is made with Nal-detectors or by high-resolution gamma spectrometry on fresh or dried samples. Precipitation collectors of a range of sizes are used to determine the activity concentration in precipitation and of dry deposited radionuclides. The analysis is made with high-resolution gamma-spectrometry, either directly on a water sample or on ion exchange resins. (au)

  15. SnagPRO: snag and tree sampling and analysis methods for wildlife

    Science.gov (United States)

    Lisa J. Bate; Michael J. Wisdom; Edward O. Garton; Shawn C. Clabough

    2008-01-01

    We describe sampling methods and provide software to accurately and efficiently estimate snag and tree densities at desired scales to meet a variety of research and management objectives. The methods optimize sampling effort by choosing a plot size appropriate for the specified forest conditions and sampling goals. Plot selection and data analyses are supported by...

  16. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality.

    Science.gov (United States)

    L'Engle, Kelly; Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne

    2018-01-01

    Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in comparison to household surveys. Random digit dialing of mobile

  17. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality.

    Directory of Open Access Journals (Sweden)

    Kelly L'Engle

    Full Text Available Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample.The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census.The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample.The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in comparison to household surveys. Random digit

  18. 222Rn in water: A comparison of two sample collection methods and two sample transport methods, and the determination of temporal variation in North Carolina ground water

    International Nuclear Information System (INIS)

    Hightower, J.H. III

    1994-01-01

    Objectives of this field experiment were: (1) determine whether there was a statistically significant difference between the radon concentrations of samples collected by EPA's standard method, using a syringe, and an alternative, slow-flow method; (2) determine whether there was a statistically significant difference between the measured radon concentrations of samples mailed vs samples not mailed; and (3) determine whether there was a temporal variation of water radon concentration over a 7-month period. The field experiment was conducted at 9 sites, 5 private wells, and 4 public wells, at various locations in North Carolina. Results showed that a syringe is not necessary for sample collection, there was generally no significant radon loss due to mailing samples, and there was statistically significant evidence of temporal variations in water radon concentrations

  19. Influences of different sample preparation methods on tooth enamel ESR signals

    International Nuclear Information System (INIS)

    Zhang Wenyi; Jiao Ling; Zhang Liang'an; Pan Zhihong; Zeng Hongyu

    2005-01-01

    Objective: To study the influences of different sample preparation methods on tooth enamel ESR signals in order to reduce the effect of dentine on their sensitivities to radiation. Methods: The enamel was separated from dentine of non-irradiated adult teeth by mechanical, chemical, or both methods. The samples of different preparations were scanned by an ESR spectrometer before and after irradiation. Results: The response of ESR signals of samples prepared with different methods to radiation dose was significantly different. Conclusion: The selection of sample preparation method is very important for dose reconstruction by tooth enamel ESR dosimetry, especially in the low dose range. (authors)

  20. Enhanced Sampling in Free Energy Calculations: Combining SGLD with the Bennett's Acceptance Ratio and Enveloping Distribution Sampling Methods.

    Science.gov (United States)

    König, Gerhard; Miller, Benjamin T; Boresch, Stefan; Wu, Xiongwu; Brooks, Bernard R

    2012-10-09

    One of the key requirements for the accurate calculation of free energy differences is proper sampling of conformational space. Especially in biological applications, molecular dynamics simulations are often confronted with rugged energy surfaces and high energy barriers, leading to insufficient sampling and, in turn, poor convergence of the free energy results. In this work, we address this problem by employing enhanced sampling methods. We explore the possibility of using self-guided Langevin dynamics (SGLD) to speed up the exploration process in free energy simulations. To obtain improved free energy differences from such simulations, it is necessary to account for the effects of the bias due to the guiding forces. We demonstrate how this can be accomplished for the Bennett's acceptance ratio (BAR) and the enveloping distribution sampling (EDS) methods. While BAR is considered among the most efficient methods available for free energy calculations, the EDS method developed by Christ and van Gunsteren is a promising development that reduces the computational costs of free energy calculations by simulating a single reference state. To evaluate the accuracy of both approaches in connection with enhanced sampling, EDS was implemented in CHARMM. For testing, we employ benchmark systems with analytical reference results and the mutation of alanine to serine. We find that SGLD with reweighting can provide accurate results for BAR and EDS where conventional molecular dynamics simulations fail. In addition, we compare the performance of EDS with other free energy methods. We briefly discuss the implications of our results and provide practical guidelines for conducting free energy simulations with SGLD.

  1. A DOE manual: DOE Methods for Evaluating Environmental and Waste Management Samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Riley, R.G.

    1994-01-01

    Waste Management inherently requires knowledge of the waste's chemical composition. The waste can often be analyzed by established methods; however, if the samples are radioactive, or are plagued by other complications, established methods may not be feasible. The US Department of Energy (DOE) has been faced with managing some waste types that are not amenable to standard or available methods, so new or modified sampling and analysis methods are required. These methods are incorporated into DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), which is a guidance/methods document for sampling and analysis activities in support of DOE sites. It is a document generated by consensus of the DOE laboratory staff and is intended to fill the gap within existing guidance documents (e. g., the Environmental Protection Agency's (EPA's) Test Methods for Evaluating Solid Waste, SW-846), which apply to low-level or non-radioactive samples. DOE Methods fills the gap by including methods that take into account the complexities of DOE site matrices. The most recent update, distributed in October 1993, contained quality assurance (QA), quality control (QC), safety, sampling, organic analysis, inorganic analysis, and radioanalytical guidance as well as 29 methods. The next update, which will be distributed in April 1994, will contain 40 methods and will therefore have greater applicability. All new methods are either peer reviewed or labeled ''draft'' methods. Draft methods were added to speed the release of methods to field personnel

  2. A Convenient Method for Estimation of the Isotopic Abundance in Uranium Bearing Samples

    International Nuclear Information System (INIS)

    AI -Saleh, F.S.; AI-Mukren, Alj.H.; Farouk, M.A.

    2008-01-01

    A convenient and simple method for estimation of the isotopic abundance in some uranium bearing samples using gamma-ray spectrometry is developed using a hyper pure germanium spectrometer and a standard uranium sample with known isotopic abundance

  3. Comparing Respondent-Driven Sampling and Targeted Sampling Methods of Recruiting Injection Drug Users in San Francisco

    Science.gov (United States)

    Malekinejad, Mohsen; Vaudrey, Jason; Martinez, Alexis N.; Lorvick, Jennifer; McFarland, Willi; Raymond, H. Fisher

    2010-01-01

    The objective of this article is to compare demographic characteristics, risk behaviors, and service utilization among injection drug users (IDUs) recruited from two separate studies in San Francisco in 2005, one which used targeted sampling (TS) and the other which used respondent-driven sampling (RDS). IDUs were recruited using TS (n = 651) and RDS (n = 534) and participated in quantitative interviews that included demographic characteristics, risk behaviors, and service utilization. Prevalence estimates and 95% confidence intervals (CIs) were calculated to assess whether there were differences in these variables by sampling method. There was overlap in 95% CIs for all demographic variables except African American race (TS: 45%, 53%; RDS: 29%, 44%). Maps showed that the proportion of IDUs distributed across zip codes were similar for the TS and RDS sample, with the exception of a single zip code that was more represented in the TS sample. This zip code includes an isolated, predominantly African American neighborhood where only the TS study had a field site. Risk behavior estimates were similar for both TS and RDS samples, although self-reported hepatitis C infection was lower in the RDS sample. In terms of service utilization, more IDUs in the RDS sample reported no recent use of drug treatment and syringe exchange program services. Our study suggests that perhaps a hybrid sampling plan is best suited for recruiting IDUs in San Francisco, whereby the more intensive ethnographic and secondary analysis components of TS would aid in the planning of seed placement and field locations for RDS. PMID:20582573

  4. Detection and monitoring of invasive exotic plants: a comparison of four sampling methods

    Science.gov (United States)

    Cynthia D. Huebner

    2007-01-01

    The ability to detect and monitor exotic invasive plants is likely to vary depending on the sampling method employed. Methods with strong qualitative thoroughness for species detection often lack the intensity necessary to monitor vegetation change. Four sampling methods (systematic plot, stratified-random plot, modified Whittaker, and timed meander) in hemlock and red...

  5. Comparison of four sampling methods for the detection of Salmonella in broiler litter.

    Science.gov (United States)

    Buhr, R J; Richardson, L J; Cason, J A; Cox, N A; Fairchild, B D

    2007-01-01

    Experiments were conducted to compare litter sampling methods for the detection of Salmonella. In experiment 1, chicks were challenged orally with a suspension of naladixic acid-resistant Salmonella and wing banded, and additional nonchallenged chicks were placed into each of 2 challenge pens. Nonchallenged chicks were placed into each nonchallenge pen located adjacent to the challenge pens. At 7, 8, 10, and 11 wk of age the litter was sampled using 4 methods: fecal droppings, litter grab, drag swab, and sock. For the challenge pens, Salmonella-positive samples were detected in 3 of 16 fecal samples, 6 of 16 litter grab samples, 7 of 16 drag swabs samples, and 7 of 16 sock samples. Samples from the nonchallenge pens were Salmonella positive in 2 of 16 litter grab samples, 9 of 16 drag swab samples, and 9 of 16 sock samples. In experiment 2, chicks were challenged with Salmonella, and the litter in the challenge and adjacent nonchallenge pens were sampled at 4, 6, and 8 wk of age with broilers remaining in all pens. For the challenge pens, Salmonella was detected in 10 of 36 fecal samples, 20 of 36 litter grab samples, 14 of 36 drag swab samples, and 26 of 36 sock samples. Samples from the adjacent nonchallenge pens were positive for Salmonella in 6 of 36 fecal droppings samples, 4 of 36 litter grab samples, 7 of 36 drag swab samples, and 19 of 36 sock samples. Sock samples had the highest rates of Salmonella detection. In experiment 3, the litter from a Salmonella-challenged flock was sampled at 7, 8, and 9 wk by socks and drag swabs. In addition, comparisons with drag swabs that were stepped on during sampling were made. Both socks (24 of 36, 67%) and drag swabs that were stepped on (25 of 36, 69%) showed significantly more Salmonella-positive samples than the traditional drag swab method (16 of 36, 44%). Drag swabs that were stepped on had comparable Salmonella detection level to that for socks. Litter sampling methods that incorporate stepping on the sample

  6. Comparability of river suspended-sediment sampling and laboratory analysis methods

    Science.gov (United States)

    Groten, Joel T.; Johnson, Gregory D.

    2018-03-06

    Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.

  7. Individual and pen-based oral fluid sampling: A welfare-friendly sampling method for group-housed gestating sows.

    Science.gov (United States)

    Pol, Françoise; Dorenlor, Virginie; Eono, Florent; Eudier, Solveig; Eveno, Eric; Liégard-Vanhecke, Dorine; Rose, Nicolas; Fablet, Christelle

    2017-11-01

    The aims of this study were to assess the feasibility of individual and pen-based oral fluid sampling (OFS) in 35 pig herds with group-housed sows, compare these methods to blood sampling, and assess the factors influencing the success of sampling. Individual samples were collected from at least 30 sows per herd. Pen-based OFS was performed using devices placed in at least three pens for 45min. Information related to the farm, the sows, and their living conditions were collected. Factors significantly associated with the duration of sampling and the chewing behaviour of sows were identified by logistic regression. Individual OFS took 2min 42s on average; the type of floor, swab size, and operator were associated with a sampling time >2min. Pen-based OFS was obtained from 112 devices (62.2%). The type of floor, parity, pen-level activity, and type of feeding were associated with chewing behaviour. Pen activity was associated with the latency to interact with the device. The type of floor, gestation stage, parity, group size, and latency to interact with the device were associated with a chewing time >10min. After 15, 30 and 45min of pen-based OFS, 48%, 60% and 65% of the sows were lying down, respectively. The time spent after the beginning of sampling, genetic type, and time elapsed since the last meal were associated with 50% of the sows lying down at one time point. The mean time to blood sample the sows was 1min 16s and 2min 52s if the number of operators required was considered in the sampling time estimation. The genetic type, parity, and type of floor were significantly associated with a sampling time higher than 1min 30s. This study shows that individual OFS is easy to perform in group-housed sows by a single operator, even though straw-bedded animals take longer to sample than animals housed on slatted floors, and suggests some guidelines to optimise pen-based OFS success. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Sampling designs and methods for estimating fish-impingement losses at cooling-water intakes

    International Nuclear Information System (INIS)

    Murarka, I.P.; Bodeau, D.J.

    1977-01-01

    Several systems for estimating fish impingement at power plant cooling-water intakes are compared to determine the most statistically efficient sampling designs and methods. Compared to a simple random sampling scheme the stratified systematic random sampling scheme, the systematic random sampling scheme, and the stratified random sampling scheme yield higher efficiencies and better estimators for the parameters in two models of fish impingement as a time-series process. Mathematical results and illustrative examples of the applications of the sampling schemes to simulated and real data are given. Some sampling designs applicable to fish-impingement studies are presented in appendixes

  9. Simulated Tempering Distributed Replica Sampling, Virtual Replica Exchange, and Other Generalized-Ensemble Methods for Conformational Sampling.

    Science.gov (United States)

    Rauscher, Sarah; Neale, Chris; Pomès, Régis

    2009-10-13

    Generalized-ensemble algorithms in temperature space have become popular tools to enhance conformational sampling in biomolecular simulations. A random walk in temperature leads to a corresponding random walk in potential energy, which can be used to cross over energetic barriers and overcome the problem of quasi-nonergodicity. In this paper, we introduce two novel methods: simulated tempering distributed replica sampling (STDR) and virtual replica exchange (VREX). These methods are designed to address the practical issues inherent in the replica exchange (RE), simulated tempering (ST), and serial replica exchange (SREM) algorithms. RE requires a large, dedicated, and homogeneous cluster of CPUs to function efficiently when applied to complex systems. ST and SREM both have the drawback of requiring extensive initial simulations, possibly adaptive, for the calculation of weight factors or potential energy distribution functions. STDR and VREX alleviate the need for lengthy initial simulations, and for synchronization and extensive communication between replicas. Both methods are therefore suitable for distributed or heterogeneous computing platforms. We perform an objective comparison of all five algorithms in terms of both implementation issues and sampling efficiency. We use disordered peptides in explicit water as test systems, for a total simulation time of over 42 μs. Efficiency is defined in terms of both structural convergence and temperature diffusion, and we show that these definitions of efficiency are in fact correlated. Importantly, we find that ST-based methods exhibit faster temperature diffusion and correspondingly faster convergence of structural properties compared to RE-based methods. Within the RE-based methods, VREX is superior to both SREM and RE. On the basis of our observations, we conclude that ST is ideal for simple systems, while STDR is well-suited for complex systems.

  10. A novel sampling method for multiple multiscale targets from scattering amplitudes at a fixed frequency

    Science.gov (United States)

    Liu, Xiaodong

    2017-08-01

    A sampling method by using scattering amplitude is proposed for shape and location reconstruction in inverse acoustic scattering problems. Only matrix multiplication is involved in the computation, thus the novel sampling method is very easy and simple to implement. With the help of the factorization of the far field operator, we establish an inf-criterion for characterization of underlying scatterers. This result is then used to give a lower bound of the proposed indicator functional for sampling points inside the scatterers. While for the sampling points outside the scatterers, we show that the indicator functional decays like the bessel functions as the sampling point goes away from the boundary of the scatterers. We also show that the proposed indicator functional continuously depends on the scattering amplitude, this further implies that the novel sampling method is extremely stable with respect to errors in the data. Different to the classical sampling method such as the linear sampling method or the factorization method, from the numerical point of view, the novel indicator takes its maximum near the boundary of the underlying target and decays like the bessel functions as the sampling points go away from the boundary. The numerical simulations also show that the proposed sampling method can deal with multiple multiscale case, even the different components are close to each other.

  11. Open Loop Heat Pipe Radiator Having a Free-Piston for Wiping Condensed Working Fluid

    Science.gov (United States)

    Weinstein, Leonard M. (Inventor)

    2015-01-01

    An open loop heat pipe radiator comprises a radiator tube and a free-piston. The radiator tube has a first end, a second end, and a tube wall, and the tube wall has an inner surface and an outer surface. The free-piston is enclosed within the radiator tube and is capable of movement within the radiator tube between the first and second ends. The free-piston defines a first space between the free-piston, the first end, and the tube wall, and further defines a second space between the free-piston, the second end, and the tube wall. A gaseous-state working fluid, which was evaporated to remove waste heat, alternately enters the first and second spaces, and the free-piston wipes condensed working fluid from the inner surface of the tube wall as the free-piston alternately moves between the first and second ends. The condensed working fluid is then pumped back to the heat source.

  12. Low pH levels wipe out salmon and trout populations in southernmost Norway

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, K W; Snekvik, E

    1972-01-01

    A gradual decrease in pH has been documented for many Scandinavian rivers and lakes and there is little doubt that the main cause is acid precipitation (1-4). Eggs, fry, and alevins of salmon and brown trout are more susceptible to acid water than are the older fish. A gradually increasing acidity of trout biotopes will cause a reduction in the natural reproduction rate of trout, because eggs and fry succumb, while the older individuals in the population survive, at least until the pH level sinks low enough to affect them, as well. A study of the present situation and examination of the available data show that the salmon populations in a number of rivers in southernmost Norway have been nearly wiped out by low pH values. During the last twenty to thirty years, low pH levels have eliminated the brown trout populations in a great number of lakes and rivers in Norway's southernmost districts. This alarming development is continuing.

  13. Concentration of a sodium nitrate-based waste with a wiped film evaporation

    International Nuclear Information System (INIS)

    Farr, L.L.; Boring, M.D.; Fowler, V.L.; Hewitt, J.D.

    1995-01-01

    Oak Ridge National Laboratory (ORNL) currently has an inventory of 500,000 gallons of sodium nitrate-based radioactive liquid waste which is currently stored in the Melton Valley Storage Tanks (MVST). This waste needs to be treated and one option being considered is concentration of the wastes using evaporation. Testing is underway to determine whether a Wiped Film Evaporator (WFE) can be used to concentrate these wastes in an economical and reliable manner. The capability of the evaporator to process a non-radioactive simulant of the MVST wastes over a range of operating conditions is being studied. The equipment has to be checked for reliability, potential corrosion problems, and the effects of the waste on the efficiency of heat transfer due to scaling. Physical and chemical characteristics of the product and distillate are being investigated. Heat transfer coefficients and volume reductions are being determined under different operating conditions. Decontamination factors are being calculated to determine the necessity for further treatment of the distillate and off-gas

  14. A standardized method for sampling and extraction methods for quantifying microplastics in beach sand.

    Science.gov (United States)

    Besley, Aiken; Vijver, Martina G; Behrens, Paul; Bosker, Thijs

    2017-01-15

    Microplastics are ubiquitous in the environment, are frequently ingested by organisms, and may potentially cause harm. A range of studies have found significant levels of microplastics in beach sand. However, there is a considerable amount of methodological variability among these studies. Methodological variation currently limits comparisons as there is no standard procedure for sampling or extraction of microplastics. We identify key sampling and extraction procedures across the literature through a detailed review. We find that sampling depth, sampling location, number of repeat extractions, and settling times are the critical parameters of variation. Next, using a case-study we determine whether and to what extent these differences impact study outcomes. By investigating the common practices identified in the literature with the case-study, we provide a standard operating procedure for sampling and extracting microplastics from beach sand. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Methods of sampling airborne fungi in working environments of waste treatment facilities.

    Science.gov (United States)

    Černá, Kristýna; Wittlingerová, Zdeňka; Zimová, Magdaléna; Janovský, Zdeněk

    2016-01-01

    The objective of the present study was to evaluate and compare the efficiency of a filter based sampling method and a high volume sampling method for sampling airborne culturable fungi present in waste sorting facilities. Membrane filters method was compared with surface air system method. The selected sampling methods were modified and tested in 2 plastic waste sorting facilities. The total number of colony-forming units (CFU)/m3 of airborne fungi was dependent on the type of sampling device, on the time of sampling, which was carried out every hour from the beginning of the work shift, and on the type of cultivation medium (p airborne fungi ranged 2×102-1.7×106 CFU/m3 when using the membrane filters (MF) method, and 3×102-6.4×104 CFU/m3 when using the surface air system (SAS) method. Both methods showed comparable sensitivity to the fluctuations of the concentrations of airborne fungi during the work shifts. The SAS method is adequate for a fast indicative determination of concentration of airborne fungi. The MF method is suitable for thorough assessment of working environment contamination by airborne fungi. Therefore we recommend the MF method for the implementation of a uniform standard methodology of airborne fungi sampling in working environments of waste treatment facilities. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  16. Fast egg collection method greatly improves randomness of egg sampling in Drosophila melanogaster

    DEFF Research Database (Denmark)

    Schou, Mads Fristrup

    2013-01-01

    When obtaining samples for population genetic studies, it is essential that the sampling is random. For Drosophila, one of the crucial steps in sampling experimental flies is the collection of eggs. Here an egg collection method is presented, which randomizes the eggs in a water column...... and diminishes environmental variance. This method was compared with a traditional egg collection method where eggs are collected directly from the medium. Within each method the observed and expected standard deviations of egg-to-adult viability were compared, whereby the difference in the randomness...... and to obtain a representative collection of genotypes, the method presented here is strongly recommended when collecting eggs from Drosophila....

  17. Wet-digestion of environmental sample using silver-mediated electrochemical method

    International Nuclear Information System (INIS)

    Kuwabara, Jun

    2010-01-01

    An application of silver-mediated electrochemical method to environmental samples as the effective digestion method for iodine analysis was tried. Usual digestion method for 129 I in many type of environmental sample is combustion method using quartz glass tube. Chemical yield of iodine on the combustion method reduce depending on the type of sample. The silver-mediated electrochemical method is expected to achieve very low loss of iodine. In this study, dried kombu (Laminaria) sample was tried to digest with electrochemical cell. At the case of 1g of sample, digestion was completed for about 24 hours under the electric condition of <10V and <2A. After the digestion, oxidized species of iodine was reduced to iodide by adding sodium sulfite. And then the precipitate of silver iodide was obtained. (author)

  18. Reliability of different methods used for forming of working samples in the laboratory for seed testing

    Directory of Open Access Journals (Sweden)

    Opra Branislava

    2000-01-01

    Full Text Available The testing of seed quality starts from the moment a sample is formed in a warehouse during processing or packaging of the seed. The seed sampling as the process of obtaining the working sample also assumes each step undertaken during its testing in the laboratory. With the aim of appropriate forming of a seed sample in the laboratory, the usage of seed divider is prescribed for large seeded species (such as seed the size of wheat or larger (ISTA Rules, 1999. The aim of this paper was the comparison of different methods used for obtaining the working samples of maize and wheat seeds using conical, soil and centrifugal dividers. The number of seed of added admixtures confirmed the reliability of working samples formation. To each maize sample (1000 g 10 seeds of the following admixtures were added: Zea mays L. (red pericarp, Hordeum vulgäre L., Triticum aestivum L., and Glycine max (L. Merr. Two methods were used for formation of maze seed working sample. To wheat samples (1000 g 10 seeds of each of the following species were added: Avena saliva (hulled seeds, Hordeum vulgäre L., Galium tricorne Stokes, and Polygonum lapatifolmm L. For formation of wheat seed working samples four methods were used. Optimum of 9, but not less than 7 seeds of admixture were due to be determined in the maize seed working sample, while for wheat, at least one seed of admixture was expected to be found in the working sample. The obtained results confirmed that the formation of the maize seed working samples was the most reliable when centrifugal divider, the first method was used (average of admixture - 9.37. From the observed admixtures the seed of Triticum aestivum L. was the most uniformly distributed, the first method also being used (6.93. The second method gains high average values satisfying the given criterion, but it should be used with previous homogenization of the sample being tested. The forming of wheat seed working samples is the most reliable if the

  19. Suitability of the line intersect method for sampling hardwood logging residues

    Science.gov (United States)

    A. Jeff Martin

    1976-01-01

    The line intersect method of sampling logging residues was tested in Appalachian hardwoods and was found to provide unbiased estimates of the volume of residue in cubic feet per acre. Thirty-two chains of sample line were established on each of sixteen 1-acre plots on cutover areas in a variety of conditions. Estimates from these samples were then compared to actual...

  20. Methods and devices for hyperpolarising and melting NMR samples in a cryostat

    DEFF Research Database (Denmark)

    Ardenkjaer-Larsen, Jan Henrik; Axelsson, Oskar H. E.; Golman, Klaes Koppel

    2006-01-01

    The present invention relates to devices and method for melting solid polarised sample while retaining a high level of polarisation. In an embodiment of the present invention a sample is polarised in a sample-retaining cup 9 in a strong magnetic field in a polarising means 3a, 3b, 3c in a cryosta...

  1. Serum chromium levels sampled with steel needle versus plastic IV cannula. Does method matter?

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Overgaard, Søren

    2010-01-01

    PURPOSE: Modern metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby...... causing bias. This study aimed to test that theory. METHODS: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. RESULTS: We found statistically significant chromium contamination from the steel needle...... with mean differences between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline...

  2. A Method for Microalgae Proteomics Analysis Based on Modified Filter-Aided Sample Preparation.

    Science.gov (United States)

    Li, Song; Cao, Xupeng; Wang, Yan; Zhu, Zhen; Zhang, Haowei; Xue, Song; Tian, Jing

    2017-11-01

    With the fast development of microalgal biofuel researches, the proteomics studies of microalgae increased quickly. A filter-aided sample preparation (FASP) method is widely used proteomics sample preparation method since 2009. Here, a method of microalgae proteomics analysis based on modified filter-aided sample preparation (mFASP) was described to meet the characteristics of microalgae cells and eliminate the error caused by over-alkylation. Using Chlamydomonas reinhardtii as the model, the prepared sample was tested by standard LC-MS/MS and compared with the previous reports. The results showed mFASP is suitable for most of occasions of microalgae proteomics studies.

  3. Universal nucleic acids sample preparation method for cells, spores and their mixture

    Science.gov (United States)

    Bavykin, Sergei [Darien, IL

    2011-01-18

    The present invention relates to a method for extracting nucleic acids from biological samples. More specifically the invention relates to a universal method for extracting nucleic acids from unidentified biological samples. An advantage of the presently invented method is its ability to effectively and efficiently extract nucleic acids from a variety of different cell types including but not limited to prokaryotic or eukaryotic cells and/or recalcitrant organisms (i.e. spores). Unlike prior art methods which are focused on extracting nucleic acids from vegetative cell or spores, the present invention effectively extracts nucleic acids from spores, multiple cell types or mixtures thereof using a single method. Important that the invented method has demonstrated an ability to extract nucleic acids from spores and vegetative bacterial cells with similar levels effectiveness. The invented method employs a multi-step protocol which erodes the cell structure of the biological sample, isolates, labels, fragments nucleic acids and purifies labeled samples from the excess of dye.

  4. Some refinements on the comparison of areal sampling methods via simulation

    Science.gov (United States)

    Jeffrey Gove

    2017-01-01

    The design of forest inventories and development of new sampling methods useful in such inventories normally have a two-fold target of design unbiasedness and minimum variance in mind. Many considerations such as costs go into the choices of sampling method for operational and other levels of inventory. However, the variance in terms of meeting a specified level of...

  5. Evaluation of beef trim sampling methods for detection of Shiga toxin-producing Escherichia coli (STEC)

    Science.gov (United States)

    Presence of Shiga toxin-producing Escherichia coli (STEC) is a major concern in ground beef. Several methods for sampling beef trim prior to grinding are currently used in the beef industry. The purpose of this study was to determine the efficacy of the sampling methods for detecting STEC in beef ...

  6. Sampling Methods and the Accredited Population in Athletic Training Education Research

    Science.gov (United States)

    Carr, W. David; Volberding, Jennifer

    2009-01-01

    Context: We describe methods of sampling the widely-studied, yet poorly defined, population of accredited athletic training education programs (ATEPs). Objective: There are two purposes to this study; first to describe the incidence and types of sampling methods used in athletic training education research, and second to clearly define the…

  7. Ionizing radiation as optimization method for aluminum detection from drinking water samples

    International Nuclear Information System (INIS)

    Bazante-Yamguish, Renata; Geraldo, Aurea Beatriz C.; Moura, Eduardo; Manzoli, Jose Eduardo

    2013-01-01

    The presence of organic compounds in water samples is often responsible for metal complexation; depending on the analytic method, the organic fraction may dissemble the evaluation of the real values of metal concentration. Pre-treatment of the samples is advised when organic compounds are interfering agents, and thus sample mineralization may be accomplished by several chemical and/or physical methods. Here, the ionizing radiation was used as an advanced oxidation process (AOP), for sample pre-treatment before the analytic determination of total and dissolved aluminum by ICP-OES in drinking water samples from wells and spring source located at Billings dam region. Before irradiation, the spring source and wells' samples showed aluminum levels of 0.020 mg/l and 0.2 mg/l respectively; after irradiation, both samples showed a 8-fold increase of aluminum concentration. These results are discussed considering other physical and chemical parameters and peculiarities of sample sources. (author)

  8. Optical method for the characterization of laterally patterned samples in integrated circuits

    Science.gov (United States)

    Maris, Humphrey J [Barrington, RI

    2009-03-17

    Disclosed is a method for characterizing a sample having a structure disposed on or within the sample, comprising the steps of applying a first pulse of light to a surface of the sample for creating a propagating strain pulse in the sample, applying a second pulse of light to the surface so that the second pulse of light interacts with the propagating strain pulse in the sample, sensing from a reflection of the second pulse a change in optical response of the sample, and relating a time of occurrence of the change in optical response to at least one dimension of the structure.

  9. Purposeful Sampling for Qualitative Data Collection and Analysis in Mixed Method Implementation Research.

    Science.gov (United States)

    Palinkas, Lawrence A; Horwitz, Sarah M; Green, Carla A; Wisdom, Jennifer P; Duan, Naihua; Hoagwood, Kimberly

    2015-09-01

    Purposeful sampling is widely used in qualitative research for the identification and selection of information-rich cases related to the phenomenon of interest. Although there are several different purposeful sampling strategies, criterion sampling appears to be used most commonly in implementation research. However, combining sampling strategies may be more appropriate to the aims of implementation research and more consistent with recent developments in quantitative methods. This paper reviews the principles and practice of purposeful sampling in implementation research, summarizes types and categories of purposeful sampling strategies and provides a set of recommendations for use of single strategy or multistage strategy designs, particularly for state implementation research.

  10. Purposeful sampling for qualitative data collection and analysis in mixed method implementation research

    Science.gov (United States)

    Palinkas, Lawrence A.; Horwitz, Sarah M.; Green, Carla A.; Wisdom, Jennifer P.; Duan, Naihua; Hoagwood, Kimberly

    2013-01-01

    Purposeful sampling is widely used in qualitative research for the identification and selection of information-rich cases related to the phenomenon of interest. Although there are several different purposeful sampling strategies, criterion sampling appears to be used most commonly in implementation research. However, combining sampling strategies may be more appropriate to the aims of implementation research and more consistent with recent developments in quantitative methods. This paper reviews the principles and practice of purposeful sampling in implementation research, summarizes types and categories of purposeful sampling strategies and provides a set of recommendations for use of single strategy or multistage strategy designs, particularly for state implementation research. PMID:24193818

  11. Quantitative method of determining beryllium or a compound thereof in a sample

    Science.gov (United States)

    McCleskey, T. Mark; Ehler, Deborah S.; John, Kevin D.; Burrell, Anthony K.; Collis, Gavin E.; Minogue, Edel M.; Warner, Benjamin P.

    2010-08-24

    A method of determining beryllium or a beryllium compound thereof in a sample, includes providing a sample suspected of comprising beryllium or a compound thereof, extracting beryllium or a compound thereof from the sample by dissolving in a solution, adding a fluorescent indicator to the solution to thereby bind any beryllium or a compound thereof to the fluorescent indicator, and determining the presence or amount of any beryllium or a compound thereof in the sample by measuring fluorescence.

  12. Estimation of the sugar cane cultivated area from LANDSAT images using the two phase sampling method

    Science.gov (United States)

    Parada, N. D. J. (Principal Investigator); Cappelletti, C. A.; Mendonca, F. J.; Lee, D. C. L.; Shimabukuro, Y. E.

    1982-01-01

    A two phase sampling method and the optimal sampling segment dimensions for the estimation of sugar cane cultivated area were developed. This technique employs visual interpretations of LANDSAT images and panchromatic aerial photographs considered as the ground truth. The estimates, as a mean value of 100 simulated samples, represent 99.3% of the true value with a CV of approximately 1%; the relative efficiency of the two phase design was 157% when compared with a one phase aerial photographs sample.

  13. Estimating HIES Data through Ratio and Regression Methods for Different Sampling Designs

    Directory of Open Access Journals (Sweden)

    Faqir Muhammad

    2007-01-01

    Full Text Available In this study, comparison has been made for different sampling designs, using the HIES data of North West Frontier Province (NWFP for 2001-02 and 1998-99 collected from the Federal Bureau of Statistics, Statistical Division, Government of Pakistan, Islamabad. The performance of the estimators has also been considered using bootstrap and Jacknife. A two-stage stratified random sample design is adopted by HIES. In the first stage, enumeration blocks and villages are treated as the first stage Primary Sampling Units (PSU. The sample PSU’s are selected with probability proportional to size. Secondary Sampling Units (SSU i.e., households are selected by systematic sampling with a random start. They have used a single study variable. We have compared the HIES technique with some other designs, which are: Stratified Simple Random Sampling. Stratified Systematic Sampling. Stratified Ranked Set Sampling. Stratified Two Phase Sampling. Ratio and Regression methods were applied with two study variables, which are: Income (y and Household sizes (x. Jacknife and Bootstrap are used for variance replication. Simple Random Sampling with sample size (462 to 561 gave moderate variances both by Jacknife and Bootstrap. By applying Systematic Sampling, we received moderate variance with sample size (467. In Jacknife with Systematic Sampling, we obtained variance of regression estimator greater than that of ratio estimator for a sample size (467 to 631. At a sample size (952 variance of ratio estimator gets greater than that of regression estimator. The most efficient design comes out to be Ranked set sampling compared with other designs. The Ranked set sampling with jackknife and bootstrap, gives minimum variance even with the smallest sample size (467. Two Phase sampling gave poor performance. Multi-stage sampling applied by HIES gave large variances especially if used with a single study variable.

  14. Two media method for linear attenuation coefficient determination of irregular soil samples

    International Nuclear Information System (INIS)

    Vici, Carlos Henrique Georges

    2004-01-01

    In several situations of nuclear applications, the knowledge of gamma-ray linear attenuation coefficient for irregular samples is necessary, such as in soil physics and geology. This work presents the validation of a methodology for the determination of the linear attenuation coefficient (μ) of irregular shape samples, in such a way that it is not necessary to know the thickness of the considered sample. With this methodology irregular soil samples (undeformed field samples) from Londrina region, north of Parana were studied. It was employed the two media method for the μ determination. It consists of the μ determination through the measurement of a gamma-ray beam attenuation by the sample sequentially immersed in two different media, with known and appropriately chosen attenuation coefficients. For comparison, the theoretical value of μ was calculated by the product of the mass attenuation coefficient, obtained by the WinXcom code, and the measured value of the density sample. This software employs the chemical composition of the samples and supplies a table of the mass attenuation coefficients versus the photon energy. To verify the validity of the two media method, compared with the simple gamma ray transmission method, regular pome stone samples were used. With these results for the attenuation coefficients and their respective deviations, it was possible to compare the two methods. In this way we concluded that the two media method is a good tool for the determination of the linear attenuation coefficient of irregular materials, particularly in the study of soils samples. (author)

  15. [Sample preparation methods for chromatographic analysis of organic components in atmospheric particulate matter].

    Science.gov (United States)

    Hao, Liang; Wu, Dapeng; Guan, Yafeng

    2014-09-01

    The determination of organic composition in atmospheric particulate matter (PM) is of great importance in understanding how PM affects human health, environment, climate, and ecosystem. Organic components are also the scientific basis for emission source tracking, PM regulation and risk management. Therefore, the molecular characterization of the organic fraction of PM has become one of the priority research issues in the field of environmental analysis. Due to the extreme complexity of PM samples, chromatographic methods have been the chief selection. The common procedure for the analysis of organic components in PM includes several steps: sample collection on the fiber filters, sample preparation (transform the sample into a form suitable for chromatographic analysis), analysis by chromatographic methods. Among these steps, the sample preparation methods will largely determine the throughput and the data quality. Solvent extraction methods followed by sample pretreatment (e. g. pre-separation, derivatization, pre-concentration) have long been used for PM sample analysis, and thermal desorption methods have also mainly focused on the non-polar organic component analysis in PM. In this paper, the sample preparation methods prior to chromatographic analysis of organic components in PM are reviewed comprehensively, and the corresponding merits and limitations of each method are also briefly discussed.

  16. Estimation of the sensitivity of various environmental sampling methods for detection of Salmonella in duck flocks.

    Science.gov (United States)

    Arnold, Mark E; Mueller-Doblies, Doris; Gosling, Rebecca J; Martelli, Francesca; Davies, Robert H

    2015-01-01

    Reports of Salmonella in ducks in the UK currently rely upon voluntary submissions from the industry, and as there is no harmonized statutory monitoring and control programme, it is difficult to compare data from different years in order to evaluate any trends in Salmonella prevalence in relation to sampling methodology. Therefore, the aim of this project was to assess the sensitivity of a selection of environmental sampling methods, including the sampling of faeces, dust and water troughs or bowls for the detection of Salmonella in duck flocks, and a range of sampling methods were applied to 67 duck flocks. Bayesian methods in the absence of a gold standard were used to provide estimates of the sensitivity of each of the sampling methods relative to the within-flock prevalence. There was a large influence of the within-flock prevalence on the sensitivity of all sample types, with sensitivity reducing as the within-flock prevalence reduced. Boot swabs (individual and pool of four), swabs of faecally contaminated areas and whole house hand-held fabric swabs showed the overall highest sensitivity for low-prevalence flocks and are recommended for use to detect Salmonella in duck flocks. The sample type with the highest proportion positive was a pool of four hair nets used as boot swabs, but this was not the most sensitive sample for low-prevalence flocks. All the environmental sampling types (faeces swabs, litter pinches, drag swabs, water trough samples and dust) had higher sensitivity than individual faeces sampling. None of the methods consistently identified all the positive flocks, and at least 10 samples would be required for even the most sensitive method (pool of four boot swabs) to detect a 5% prevalence. The sampling of dust had a low sensitivity and is not recommended for ducks.

  17. Effect on skin hydration of using baby wipes to clean the napkin area of newborn babies: assessor-blinded randomised controlled equivalence trial.

    Science.gov (United States)

    Lavender, Tina; Furber, Christine; Campbell, Malcolm; Victor, Suresh; Roberts, Ian; Bedwell, Carol; Cork, Michael J

    2012-06-01

    Some national guidelines recommend the use of water alone for napkin cleansing. Yet, there is a readiness, amongst many parents, to use baby wipes. Evidence from randomised controlled trials, of the effect of baby wipes on newborn skin integrity is lacking. We conducted a study to examine the hypothesis that the use of a specifically formulated cleansing wipe on the napkin area of newborn infants (skin hydration when compared with using cotton wool and water (usual care). A prospective, assessor-blinded, randomised controlled equivalence trial was conducted during 2010. Healthy, term babies (n=280), recruited within 48 hours of birth, were randomly assigned to have their napkin area cleansed with an alcohol-free baby wipe (140 babies) or cotton wool and water (140 babies). Primary outcome was change in hydration from within 48 hours of birth to 4 weeks post-birth. Secondary outcomes comprised changes in trans-epidermal water loss, skin surface pH and erythema, presence of microbial skin contaminants/irritants at 4 weeks and napkin dermatitis reported by midwife at 4 weeks and mother during the 4 weeks. Complete hydration data were obtained for 254 (90.7 %) babies. Wipes were shown to be equivalent to water and cotton wool in terms of skin hydration (intention-to-treat analysis: wipes 65.4 (SD 12.4) vs. water 63.5 (14.2), p=0.47, 95% CI -2.5 to 4.2; per protocol analysis: wipes 64.6 (12.4) vs. water 63.6 (14.3), p=0.53, 95% CI -2.4 to 4.2). No significant differences were found in the secondary outcomes, except for maternal-reported napkin dermatitis, which was higher in the water group (p=0.025 for complete responses). Baby wipes had an equivalent effect on skin hydration when compared with cotton wool and water. We found no evidence of any adverse effects of using these wipes. These findings offer reassurance to parents who choose to use baby wipes and to health professionals who support their use. Current Controlled Trials ISRCTN86207019.

  18. The impact of different blood sampling methods on laboratory rats under different types of anaesthesia

    DEFF Research Database (Denmark)

    Toft, Martin Fitzner; Petersen, Mikke Haxø; Dragsted, Nils

    2006-01-01

    for rats sampled from the tail vein, which showed fluctuations in body temperature in excess of 30 h after sampling. Increases in heart rate and blood pressure within the first hours after sampling indicated that periorbital puncture was the method that had the largest acute impact on the rats......Rats with implanted telemetry transponders were blood sampled by jugular puncture, periorbital puncture or tail vein puncture, or sampled by jugular puncture in carbon dioxide (CO?), isoflurane or without anaesthesia in a crossover design. Heart rate, blood pressure and body temperature were...... registered for three days after sampling. Initially blood pressure increased, but shortly after sampling it decreased, which led to increased heart rate. Sampling induced rapid fluctuations in body temperature, and an increase in body temperature. Generally, rats recovered from sampling within 2-3 h, except...

  19. Use of Monte Carlo Bootstrap Method in the Analysis of Sample Sufficiency for Radioecological Data

    International Nuclear Information System (INIS)

    Silva, A. N. C. da; Amaral, R. S.; Araujo Santos Jr, J.; Wilson Vieira, J.; Lima, F. R. de A.

    2015-01-01

    There are operational difficulties in obtaining samples for radioecological studies. Population data may no longer be available during the study and obtaining new samples may not be possible. These problems do the researcher sometimes work with a small number of data. Therefore, it is difficult to know whether the number of samples will be sufficient to estimate the desired parameter. Hence, it is critical do the analysis of sample sufficiency. It is not interesting uses the classical methods of statistic to analyze sample sufficiency in Radioecology, because naturally occurring radionuclides have a random distribution in soil, usually arise outliers and gaps with missing values. The present work was developed aiming to apply the Monte Carlo Bootstrap method in the analysis of sample sufficiency with quantitative estimation of a single variable such as specific activity of a natural radioisotope present in plants. The pseudo population was a small sample with 14 values of specific activity of 226 Ra in forage palm (Opuntia spp.). Using the R software was performed a computational procedure to calculate the number of the sample values. The re sampling process with replacement took the 14 values of original sample and produced 10,000 bootstrap samples for each round. Then was calculated the estimated average θ for samples with 2, 5, 8, 11 and 14 values randomly selected. The results showed that if the researcher work with only 11 sample values, the average parameter will be within a confidence interval with 90% probability . (Author)

  20. Validation of the Cristallini Sampling Method for UF6 by High Precision Double-Spike Measurements

    OpenAIRE

    RICHTER STEPHAN; JAKOBSSON ULF; HIESS JOE; AMARAGGI D.

    2017-01-01

    The so-called "Cristallini Method" for sampling of UF6 by adsorption and hydrolysis in alumina pellets inside a fluorothene P-10 tube was developed by the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC) several years ago. This method has several advantages compared to the currently used sampling method, for which UF6 is distilled into a stainless steel tube for transportation, with hydrolysis and isotopic analysis being performed after shipping to the analyt...

  1. Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

    Energy Technology Data Exchange (ETDEWEB)

    Adamic, M.L., E-mail: Mary.Adamic@inl.gov [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States); Lister, T.E.; Dufek, E.J.; Jenson, D.D.; Olson, J.E. [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States); Vockenhuber, C. [Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, 8093 Zurich (Switzerland); Watrous, M.G. [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States)

    2015-10-15

    This paper presents an evaluation of an alternate method for preparing environmental samples for {sup 129}I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

  2. Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

    International Nuclear Information System (INIS)

    Adamic, M.L.; Lister, T.E.; Dufek, E.J.; Jenson, D.D.; Olson, J.E.; Vockenhuber, C.; Watrous, M.G.

    2015-01-01

    This paper presents an evaluation of an alternate method for preparing environmental samples for "1"2"9I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

  3. Method validation and uncertainty evaluation of organically bound tritium analysis in environmental sample.

    Science.gov (United States)

    Huang, Yan-Jun; Zeng, Fan; Zhang, Bing; Chen, Chao-Feng; Qin, Hong-Juan; Wu, Lian-Sheng; Guo, Gui-Yin; Yang, Li-Tao; Shang-Guan, Zhi-Hong

    2014-08-01

    The analytical method for organically bound tritium (OBT) was developed in our laboratory. The optimized operating conditions and parameters were established for sample drying, special combustion, distillation, and measurement on a liquid scintillation spectrometer (LSC). Selected types of OBT samples such as rice, corn, rapeseed, fresh lettuce and pork were analyzed for method validation of recovery rate reproducibility, the minimum detection concentration, and the uncertainty for typical low level environmental sample was evaluated. The combustion water recovery rate of different dried environmental sample was kept at about 80%, the minimum detection concentration of OBT ranged from 0.61 to 0.89 Bq/kg (dry weight), depending on the hydrogen content. It showed that this method is suitable for OBT analysis of environmental sample with stable recovery rate, and the combustion water yield of a sample with weight about 40 g would provide sufficient quantity for measurement on LSC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Comparison of microstickies measurement methods. Part I, sample preparation and measurement methods

    Science.gov (United States)

    Mahendra R. Doshi; Angeles Blanco; Carlos Negro; Gilles M. Dorris; Carlos C. Castro; Axel Hamann; R. Daniel Haynes; Carl Houtman; Karen Scallon; Hans-Joachim Putz; Hans Johansson; R.A. Venditti; K. Copeland; H.-M. Chang

    2003-01-01

    Recently, we completed a project on the comparison of macrostickies measurement methods. Based on the success of the project, we decided to embark on this new project on comparison of microstickies measurement methods. When we started this project, there were some concerns and doubts principally due to the lack of an accepted definition of microstickies. However, we...

  5. An adaptive Monte Carlo method under emission point as sampling station for deep penetration calculation

    International Nuclear Information System (INIS)

    Wang, Ruihong; Yang, Shulin; Pei, Lucheng

    2011-01-01

    Deep penetration problem has been one of the difficult problems in shielding calculation with Monte Carlo method for several decades. In this paper, an adaptive technique under the emission point as a sampling station is presented. The main advantage is to choose the most suitable sampling number from the emission point station to get the minimum value of the total cost in the process of the random walk. Further, the related importance sampling method is also derived. The main principle is to define the importance function of the response due to the particle state and ensure the sampling number of the emission particle is proportional to the importance function. The numerical results show that the adaptive method under the emission point as a station could overcome the difficulty of underestimation to the result in some degree, and the related importance sampling method gets satisfied results as well. (author)

  6. Analysis of methods commonly used in biomedicine for treatment versus control comparison of very small samples.

    Science.gov (United States)

    Ristić-Djurović, Jasna L; Ćirković, Saša; Mladenović, Pavle; Romčević, Nebojša; Trbovich, Alexander M

    2018-04-01

    A rough estimate indicated that use of samples of size not larger than ten is not uncommon in biomedical research and that many of such studies are limited to strong effects due to sample sizes smaller than six. For data collected from biomedical experiments it is also often unknown if mathematical requirements incorporated in the sample comparison methods are satisfied. Computer simulated experiments were used to examine performance of methods for qualitative sample comparison and its dependence on the effectiveness of exposure, effect intensity, distribution of studied parameter values in the population, and sample size. The Type I and Type II errors, their average, as well as the maximal errors were considered. The sample size 9 and the t-test method with p = 5% ensured error smaller than 5% even for weak effects. For sample sizes 6-8 the same method enabled detection of weak effects with errors smaller than 20%. If the sample sizes were 3-5, weak effects could not be detected with an acceptable error; however, the smallest maximal error in the most general case that includes weak effects is granted by the standard error of the mean method. The increase of sample size from 5 to 9 led to seven times more accurate detection of weak effects. Strong effects were detected regardless of the sample size and method used. The minimal recommended sample size for biomedical experiments is 9. Use of smaller sizes and the method of their comparison should be justified by the objective of the experiment. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Sampling for Patient Exit Interviews: Assessment of Methods Using Mathematical Derivation and Computer Simulations.

    Science.gov (United States)

    Geldsetzer, Pascal; Fink, Günther; Vaikath, Maria; Bärnighausen, Till

    2018-02-01

    (1) To evaluate the operational efficiency of various sampling methods for patient exit interviews; (2) to discuss under what circumstances each method yields an unbiased sample; and (3) to propose a new, operationally efficient, and unbiased sampling method. Literature review, mathematical derivation, and Monte Carlo simulations. Our simulations show that in patient exit interviews it is most operationally efficient if the interviewer, after completing an interview, selects the next patient exiting the clinical consultation. We demonstrate mathematically that this method yields a biased sample: patients who spend a longer time with the clinician are overrepresented. This bias can be removed by selecting the next patient who enters, rather than exits, the consultation room. We show that this sampling method is operationally more efficient than alternative methods (systematic and simple random sampling) in most primary health care settings. Under the assumption that the order in which patients enter the consultation room is unrelated to the length of time spent with the clinician and the interviewer, selecting the next patient entering the consultation room tends to be the operationally most efficient unbiased sampling method for patient exit interviews. © 2016 The Authors. Health Services Research published by Wiley Periodicals, Inc. on behalf of Health Research and Educational Trust.

  8. [Sampling methods for PM2.5 from stationary sources: a review].

    Science.gov (United States)

    Jiang, Jing-Kun; Deng, Jian-Guo; Li, Zhen; Li, Xing-Hua; Duan, Lei; Hao, Ji-Ming

    2014-05-01

    The new China national ambient air quality standard has been published in 2012 and will be implemented in 2016. To meet the requirements in this new standard, monitoring and controlling PM2,,5 emission from stationary sources are very important. However, so far there is no national standard method on sampling PM2.5 from stationary sources. Different sampling methods for PM2.5 from stationary sources and relevant international standards were reviewed in this study. It includes the methods for PM2.5 sampling in flue gas and the methods for PM2.5 sampling after dilution. Both advantages and disadvantages of these sampling methods were discussed. For environmental management, the method for PM2.5 sampling in flue gas such as impactor and virtual impactor was suggested as a standard to determine filterable PM2.5. To evaluate environmental and health effects of PM2.5 from stationary sources, standard dilution method for sampling of total PM2.5 should be established.

  9. Intercomparison study of sampling methods for the determination of polychlorinated biphenyl (PCB) in seawater

    International Nuclear Information System (INIS)

    Schulz-Bull, D.E.

    1999-01-01

    The determination of organic pollutants in seawater is a serious problem, as their concentrations in the water column are typical in the fg - ng/L range. Available methods therefore includes extensive sampling and laboratory work. The development of simple sampling techniques for organochlorines (e.g. passive sampling with semipermeable membrane device (SPMD), mussel watch) is required. Three methods for the measurement of trace organochlorines in seawater were investigated: (1) the filtration (GF/F) and extraction (XAD-2 resin) of seawater with an in-situ pumping system, (2) biological-accumulation by mussels (mytilus edulis) and (3) passive sampling with SPMD

  10. Probabilistic finite element stiffness of a laterally loaded monopile based on an improved asymptotic sampling method

    DEFF Research Database (Denmark)

    Vahdatirad, Mohammadjavad; Bayat, Mehdi; Andersen, Lars Vabbersgaard

    2015-01-01

    shear strength of clay. Normal and Sobol sampling are employed to provide the asymptotic sampling method to generate the probability distribution of the foundation stiffnesses. Monte Carlo simulation is used as a benchmark. Asymptotic sampling accompanied with Sobol quasi random sampling demonstrates......The mechanical responses of an offshore monopile foundation mounted in over-consolidated clay are calculated by employing a stochastic approach where a nonlinear p–y curve is incorporated with a finite element scheme. The random field theory is applied to represent a spatial variation for undrained...... an efficient method for estimating the probability distribution of stiffnesses for the offshore monopile foundation....

  11. Trace element analysis of environmental samples by multiple prompt gamma-ray analysis method

    International Nuclear Information System (INIS)

    Oshima, Masumi; Matsuo, Motoyuki; Shozugawa, Katsumi

    2011-01-01

    The multiple γ-ray detection method has been proved to be a high-resolution and high-sensitivity method in application to nuclide quantification. The neutron prompt γ-ray analysis method is successfully extended by combining it with the γ-ray detection method, which is called Multiple prompt γ-ray analysis, MPGA. In this review we show the principle of this method and its characteristics. Several examples of its application to environmental samples, especially river sediments in the urban area and sea sediment samples are also described. (author)

  12. Evaluation of sampling methods for the detection of Salmonella in broiler flocks

    DEFF Research Database (Denmark)

    Skov, Marianne N.; Carstensen, B.; Tornoe, N.

    1999-01-01

    The present study compares four different sampling methods potentially applicable to detection of Salmonella in broiler flocks, based on collection of faecal samples (i) by hand, 300 fresh faecal samples (ii) absorbed on five sheets of paper (iii) absorbed on five pairs of socks (elastic cotton...... horizontal or vertical) were found in the investigation. The results showed that the sock method (five pairs of socks) had a sensitivity comparable with the hand collection method (60 pools of five faecal samples); the paper collection method was inferior, as was the use of only one pair of socks, Estimation...... tubes pulled over the boots and termed 'socks') and (iv) by using only one pair of socks. Twenty-three broiler flocks were included in the investigation and 18 of these were found to be positive by at least one method. Seven serotypes of Salmonella with different patterns of transmission (mainly...

  13. [Standard sample preparation method for quick determination of trace elements in plastic].

    Science.gov (United States)

    Yao, Wen-Qing; Zong, Rui-Long; Zhu, Yong-Fa

    2011-08-01

    Reference sample was prepared by masterbatch method, containing heavy metals with known concentration of electronic information products (plastic), the repeatability and precision were determined, and reference sample preparation procedures were established. X-Ray fluorescence spectroscopy (XRF) analysis method was used to determine the repeatability and uncertainty in the analysis of the sample of heavy metals and bromine element. The working curve and the metrical methods for the reference sample were carried out. The results showed that the use of the method in the 200-2000 mg x kg(-1) concentration range for Hg, Pb, Cr and Br elements, and in the 20-200 mg x kg(-1) range for Cd elements, exhibited a very good linear relationship, and the repeatability of analysis methods for six times is good. In testing the circuit board ICB288G and ICB288 from the Mitsubishi Heavy Industry Company, results agreed with the recommended values.

  14. Optimal sampling strategies to assess inulin clearance in children by the inulin single-injection method

    NARCIS (Netherlands)

    van Rossum, Lyonne K.; Mathot, Ron A. A.; Cransberg, Karlien; Vulto, Arnold G.

    2003-01-01

    Glomerular filtration rate in patients can be determined by estimating the plasma clearance of inulin with the single-injection method. In this method, a single bolus injection of inulin is administered and several blood samples are collected. For practical and convenient application of this method

  15. 40 CFR 80.580 - What are the sampling and testing methods for sulfur?

    Science.gov (United States)

    2010-07-01

    ... [email protected] from the ASTM Web site of http://www.astm.org. (i) ASTM standard method D2622-05 (“ASTM... methods for sulfur? 80.580 Section 80.580 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... the sampling and testing methods for sulfur? The sulfur content of diesel fuel and diesel fuel...

  16. Research and application of sampling and analysis method of sodium aerosol

    International Nuclear Information System (INIS)

    Yu Xiaochen; Guo Qingzhou; Wen Ximeng

    1998-01-01

    Method of sampling-analysis for sodium aerosol is researched. The vacuum sampling technology is used in the sampling process, and the analysis method adopted is volumetric analysis and atomic absorption. When the absolute content of sodium is in the rang of 0.1 mg to 1.0 mg, the deviation of results between volumetric analysis and atomic absorption is less than 2%. The method has been applied in a sodium aerosol removal device successfully. The analysis range, accuracy and precision can meet the requirements for researching sodium aerosol

  17. Quantification of total aluminium concentrations in food samples at trace levels by INAA and PIGE methods

    International Nuclear Information System (INIS)

    Nanda, Braja B.; Acharya, R.

    2017-01-01

    Total aluminium contents in various food samples were determined by Instrumental Neutron Activation Analysis (INAA) and Particle Induced Gamma-ray Emission (PIGE) methods. A total of 16 rice samples, collected from the field, were analyzed by INAA using reactor neutrons from Dhruva reactor. Whereas a total 17 spices collected from market, were analyzed by both INAA and PIGE methods in conjunction with high resolution gamma-ray spectrometry. Aluminium concentration values were found to be in the range of 19-845 mg kg -1 for spices and 15-104 mg kg -1 for rice samples. The methods were validated by analyzing standard reference materials (SRMs) form NIST. (author)

  18. Rapid method to determine actinides and 89/90Sr in limestone and marble samples

    International Nuclear Information System (INIS)

    Maxwell, S.L.; Culligan, Brian; Hutchison, J.B.; Utsey, R.C.; Sudowe, Ralf; McAlister, D.R.

    2016-01-01

    A new method for the determination of actinides and radiostrontium in limestone and marble samples has been developed that utilizes a rapid sodium hydroxide fusion to digest the sample. Following rapid pre-concentration steps to remove sample matrix interferences, the actinides and 89 / 90 Sr are separated using extraction chromatographic resins and measured radiometrically. The advantages of sodium hydroxide fusion versus other fusion techniques will be discussed. This approach has a sample preparation time for limestone and marble samples of <4 h. (author)

  19. A Sequential Kriging reliability analysis method with characteristics of adaptive sampling regions and parallelizability

    International Nuclear Information System (INIS)

    Wen, Zhixun; Pei, Haiqing; Liu, Hai; Yue, Zhufeng

    2016-01-01

    The sequential Kriging reliability analysis (SKRA) method has been developed in recent years for nonlinear implicit response functions which are expensive to evaluate. This type of method includes EGRA: the efficient reliability analysis method, and AK-MCS: the active learning reliability method combining Kriging model and Monte Carlo simulation. The purpose of this paper is to improve SKRA by adaptive sampling regions and parallelizability. The adaptive sampling regions strategy is proposed to avoid selecting samples in regions where the probability density is so low that the accuracy of these regions has negligible effects on the results. The size of the sampling regions is adapted according to the failure probability calculated by last iteration. Two parallel strategies are introduced and compared, aimed at selecting multiple sample points at a time. The improvement is verified through several troublesome examples. - Highlights: • The ISKRA method improves the efficiency of SKRA. • Adaptive sampling regions strategy reduces the number of needed samples. • The two parallel strategies reduce the number of needed iterations. • The accuracy of the optimal value impacts the number of samples significantly.

  20. Determination of Glucocorticoids in UPLC-MS in Environmental Samples from an Occupational Setting

    Directory of Open Access Journals (Sweden)

    Enrico Oddone

    2015-01-01

    Full Text Available Occupational exposures to glucocorticoids are still a neglected issue in some work environments, including pharmaceutical plants. We developed an analytical method to quantify simultaneously 21 glucocorticoids using UPLC coupled with mass spectrometry to provide a basis to carry out environmental monitoring. Samples were taken from air, hand-washing tests, pad-tests and wipe-tests. This paper reports the contents of the analytical methodology, along with the results of this extensive environmental and personal monitoring of glucocorticoids. The method in UPLC-MS turned out to be suitable and effective for the aim of the study. Wipe-test and pad-test desorption was carried out using 50 mL syringes, a simple technique that saves time without adversely affecting analyte recovery. Results showed a widespread environmental pollution due to glucocorticoids. This is of particular concern. Evaluation of the dose absorbed by each worker and identification of a biomarker for occupational exposure will contribute to assessment and prevention of occupational exposure.

  1. Comparing two sampling methods to engage hard-to-reach communities in research priority setting

    Directory of Open Access Journals (Sweden)

    Melissa A. Valerio

    2016-10-01

    Full Text Available Abstract Background Effective community-partnered and patient-centered outcomes research needs to address community priorities. However, optimal sampling methods to engage stakeholders from hard-to-reach, vulnerable communities to generate research priorities have not been identified. Methods In two similar rural, largely Hispanic communities, a community advisory board guided recruitment of stakeholders affected by chronic pain using a different method in each community: 1 snowball sampling, a chain- referral method or 2 purposive sampling to recruit diverse stakeholders. In both communities, three groups of stakeholders attended a series of three facilitated meetings to orient, brainstorm, and prioritize ideas (9 meetings/community. Using mixed methods analysis, we compared stakeholder recruitment and retention as well as priorities from both communities’ stakeholders on mean ratings of their ideas based on importance and feasibility for implementation in their community. Results Of 65 eligible stakeholders in one community recruited by snowball sampling, 55 (85 % consented, 52 (95 % attended the first meeting, and 36 (65 % attended all 3 meetings. In the second community, the purposive sampling method was supplemented by convenience sampling to increase recruitment. Of 69 stakeholders recruited by this combined strategy, 62 (90 % consented, 36 (58 % attended the first meeting, and 26 (42 % attended all 3 meetings. Snowball sampling recruited more Hispanics and disabled persons (all P < 0.05. Despite differing recruitment strategies, stakeholders from the two communities identified largely similar ideas for research, focusing on non-pharmacologic interventions for management of chronic pain. Ratings on importance and feasibility for community implementation differed only on the importance of massage services (P = 0.045 which was higher for the purposive/convenience sampling group and for city improvements

  2. Novel joint selection methods can reduce sample size for rheumatoid arthritis clinical trials with ultrasound endpoints.

    Science.gov (United States)

    Allen, John C; Thumboo, Julian; Lye, Weng Kit; Conaghan, Philip G; Chew, Li-Ching; Tan, York Kiat

    2018-03-01

    To determine whether novel methods of selecting joints through (i) ultrasonography (individualized-ultrasound [IUS] method), or (ii) ultrasonography and clinical examination (individualized-composite-ultrasound [ICUS] method) translate into smaller rheumatoid arthritis (RA) clinical trial sample sizes when compared to existing methods utilizing predetermined joint sites for ultrasonography. Cohen's effect size (ES) was estimated (ES^) and a 95% CI (ES^L, ES^U) calculated on a mean change in 3-month total inflammatory score for each method. Corresponding 95% CIs [nL(ES^U), nU(ES^L)] were obtained on a post hoc sample size reflecting the uncertainty in ES^. Sample size calculations were based on a one-sample t-test as the patient numbers needed to provide 80% power at α = 0.05 to reject a null hypothesis H 0 : ES = 0 versus alternative hypotheses H 1 : ES = ES^, ES = ES^L and ES = ES^U. We aimed to provide point and interval estimates on projected sample sizes for future studies reflecting the uncertainty in our study ES^S. Twenty-four treated RA patients were followed up for 3 months. Utilizing the 12-joint approach and existing methods, the post hoc sample size (95% CI) was 22 (10-245). Corresponding sample sizes using ICUS and IUS were 11 (7-40) and 11 (6-38), respectively. Utilizing a seven-joint approach, the corresponding sample sizes using ICUS and IUS methods were nine (6-24) and 11 (6-35), respectively. Our pilot study suggests that sample size for RA clinical trials with ultrasound endpoints may be reduced using the novel methods, providing justification for larger studies to confirm these observations. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  3. Estimation of functional failure probability of passive systems based on adaptive importance sampling method

    International Nuclear Information System (INIS)

    Wang Baosheng; Wang Dongqing; Zhang Jianmin; Jiang Jing

    2012-01-01

    In order to estimate the functional failure probability of passive systems, an innovative adaptive importance sampling methodology is presented. In the proposed methodology, information of variables is extracted with some pre-sampling of points in the failure region. An important sampling density is then constructed from the sample distribution in the failure region. Taking the AP1000 passive residual heat removal system as an example, the uncertainties related to the model of a passive system and the numerical values of its input parameters are considered in this paper. And then the probability of functional failure is estimated with the combination of the response surface method and adaptive importance sampling method. The numerical results demonstrate the high computed efficiency and excellent computed accuracy of the methodology compared with traditional probability analysis methods. (authors)

  4. A METHOD FOR PREPARING A SUBSTRATE BY APPLYING A SAMPLE TO BE ANALYSED

    DEFF Research Database (Denmark)

    2017-01-01

    The invention relates to a method for preparing a substrate (105a) comprising a sample reception area (110) and a sensing area (111). The method comprises the steps of: 1) applying a sample on the sample reception area; 2) rotating the substrate around a predetermined axis; 3) during rotation......, at least part of the liquid travels from the sample reception area to the sensing area due to capillary forces acting between the liquid and the substrate; and 4) removing the wave of particles and liquid formed at one end of the substrate. The sensing area is closer to the predetermined axis than...... the sample reception area. The sample comprises a liquid part and particles suspended therein....

  5. An improved correlated sampling method for calculating correction factor of detector

    International Nuclear Information System (INIS)

    Wu Zhen; Li Junli; Cheng Jianping

    2006-01-01

    In the case of a small size detector lying inside a bulk of medium, there are two problems in the correction factors calculation of the detectors. One is that the detector is too small for the particles to arrive at and collide in; the other is that the ratio of two quantities is not accurate enough. The method discussed in this paper, which combines correlated sampling with modified particle collision auto-importance sampling, and has been realized on the MCNP-4C platform, can solve these two problems. Besides, other 3 variance reduction techniques are also combined with correlated sampling respectively to calculate a simple calculating model of the correction factors of detectors. The results prove that, although all the variance reduction techniques combined with correlated sampling can improve the calculating efficiency, the method combining the modified particle collision auto-importance sampling with the correlated sampling is the most efficient one. (authors)

  6. Calculation of parameter failure probability of thermodynamic system by response surface and importance sampling method

    International Nuclear Information System (INIS)

    Shang Yanlong; Cai Qi; Chen Lisheng; Zhang Yangwei

    2012-01-01

    In this paper, the combined method of response surface and importance sampling was applied for calculation of parameter failure probability of the thermodynamic system. The mathematics model was present for the parameter failure of physics process in the thermodynamic system, by which the combination arithmetic model of response surface and importance sampling was established, then the performance degradation model of the components and the simulation process of parameter failure in the physics process of thermodynamic system were also present. The parameter failure probability of the purification water system in nuclear reactor was obtained by the combination method. The results show that the combination method is an effective method for the calculation of the parameter failure probability of the thermodynamic system with high dimensionality and non-linear characteristics, because of the satisfactory precision with less computing time than the direct sampling method and the drawbacks of response surface method. (authors)

  7. INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING CHARACTERIZATION FACILITY (WSCF)

    International Nuclear Information System (INIS)

    DOUGLAS JG; MEZNARICH HD, PHD; OLSEN JR; ROSS GA; STAUFFER M

    2008-01-01

    Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-846 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (S and GRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a 'blind' sample to the laboratory. Feedback from the S and GRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 2008a). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated-carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more

  8. Comparing two sampling methods to engage hard-to-reach communities in research priority setting.

    Science.gov (United States)

    Valerio, Melissa A; Rodriguez, Natalia; Winkler, Paula; Lopez, Jaime; Dennison, Meagen; Liang, Yuanyuan; Turner, Barbara J

    2016-10-28

    Effective community-partnered and patient-centered outcomes research needs to address community priorities. However, optimal sampling methods to engage stakeholders from hard-to-reach, vulnerable communities to generate research priorities have not been identified. In two similar rural, largely Hispanic communities, a community advisory board guided recruitment of stakeholders affected by chronic pain using a different method in each community: 1) snowball sampling, a chain- referral method or 2) purposive sampling to recruit diverse stakeholders. In both communities, three groups of stakeholders attended a series of three facilitated meetings to orient, brainstorm, and prioritize ideas (9 meetings/community). Using mixed methods analysis, we compared stakeholder recruitment and retention as well as priorities from both communities' stakeholders on mean ratings of their ideas based on importance and feasibility for implementation in their community. Of 65 eligible stakeholders in one community recruited by snowball sampling, 55 (85 %) consented, 52 (95 %) attended the first meeting, and 36 (65 %) attended all 3 meetings. In the second community, the purposive sampling method was supplemented by convenience sampling to increase recruitment. Of 69 stakeholders recruited by this combined strategy, 62 (90 %) consented, 36 (58 %) attended the first meeting, and 26 (42 %) attended all 3 meetings. Snowball sampling recruited more Hispanics and disabled persons (all P research, focusing on non-pharmacologic interventions for management of chronic pain. Ratings on importance and feasibility for community implementation differed only on the importance of massage services (P = 0.045) which was higher for the purposive/convenience sampling group and for city improvements/transportation services (P = 0.004) which was higher for the snowball sampling group. In each of the two similar hard-to-reach communities, a community advisory board partnered with researchers

  9. Sampling Methods for Detection and Monitoring of the Asian Citrus Psyllid (Hemiptera: Psyllidae).

    Science.gov (United States)

    Monzo, C; Arevalo, H A; Jones, M M; Vanaclocha, P; Croxton, S D; Qureshi, J A; Stansly, P A

    2015-06-01

    The Asian citrus psyllid (ACP), Diaphorina citri Kuwayama is a key pest of citrus due to its role as vector of citrus greening disease or "huanglongbing." ACP monitoring is considered an indispensable tool for management of vector and disease. In the present study, datasets collected between 2009 and 2013 from 245 citrus blocks were used to evaluate precision, sensitivity for detection, and efficiency of five sampling methods. The number of samples needed to reach a 0.25 standard error-mean ratio was estimated using Taylor's power law and used to compare precision among sampling methods. Comparison of detection sensitivity and time expenditure (cost) between stem-tap and other sampling methodologies conducted consecutively at the same location were also assessed. Stem-tap sampling was the most efficient sampling method when ACP densities were moderate to high and served as the basis for comparison with all other methods. Protocols that grouped trees near randomly selected locations across the block were more efficient than sampling trees at random across the block. Sweep net sampling was similar to stem-taps in number of captures per sampled unit, but less precise at any ACP density. Yellow sticky traps were 14 times more sensitive than stem-taps but much more time consuming and thus less efficient except at very low population densities. Visual sampling was efficient for detecting and monitoring ACP at low densities. Suction sampling was time consuming and taxing but the most sensitive of all methods for detection of sparse populations. This information can be used to optimize ACP monitoring efforts. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Validation of curve-fitting method for blood retention of 99mTc-GSA. Comparison with blood sampling method

    International Nuclear Information System (INIS)

    Ha-Kawa, Sang Kil; Suga, Yutaka; Kouda, Katsuyasu; Ikeda, Koshi; Tanaka, Yoshimasa

    1997-01-01

    We investigated a curve-fitting method for the rate of blood retention of 99m Tc-galactosyl serum albumin (GSA) as a substitute for the blood sampling method. Seven healthy volunteers and 27 patients with liver disease underwent 99m Tc-GSA scanning. After normalization of the y-intercept as 100 percent, a biexponential regression curve for the precordial time-activity curve provided the percent injected dose (%ID) of 99m Tc-GSA in the blood without blood sampling. The discrepancy between %ID obtained by the curve-fitting method and that by the multiple blood samples was minimal in normal volunteers 3.1±2.1% (mean±standard deviation, n=77 sampling). Slightly greater discrepancy was observed in patients with liver disease (7.5±6.1%, n=135 sampling). The %ID at 15 min after injection obtained from the fitted curve was significantly greater in patients with liver cirrhosis than in the controls (53.2±11.6%, n=13; vs. 31.9±2.8%, n=7, p 99m Tc-GSA and the plasma retention rate for indocyanine green (r=-0.869, p 99m Tc-GSA and could be a substitute for the blood sampling method. (author)

  11. Effect of milk sample delivery methods and arrival conditions on bacterial contamination rates.

    Science.gov (United States)

    Dinsmore, R P; English, P B; Matthews, J C; Sears, P M

    1990-07-01

    A cross sectional study was performed of factors believed to contribute to the contamination of bovine milk sample cultures submitted to the Ithaca Regional Laboratory of the Quality Milk Promotion Services/New York State Mastitis Control. Of 871 samples entered in the study, 137 (15.7%) were contaminated. There were interactions between the sample source (veterinarian vs dairyman), delivery method, and time between sample collection and arrival at the laboratory. If only those samples collected and hand delivered by the dairyman within 1 day of collection were compared to a like subset of samples collected and hand delivered by veterinarians, no statistically significant differences in milk sample contamination rate (MSCR) were found. Samples were delivered to the laboratory by hand, US Postal Service, United Parcel Service, via the New York State College of Veterinary Medicine Diagnostic Laboratory, or Northeast Dairy Herd Improvement Association Courier. The MSCR was only 7.6% for hand delivered samples, while 26% of Postal Service samples were contaminated. These rates differed significantly from other delivery methods (P less than 0.0001). The USPS samples arrived a longer time after sampling than did samples sent by other routes, and time had a significant effect on MSCR (0 to 1 day, 8.9%; greater than 1 day, 25.9%; P less than 0.01). Samples packaged with ice packs sent by routes other than the Postal Service had a lower MSCR than those not packaged with ice packs, but ice packs did not reduce the MSCR for samples sent by the Postal Service.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    Science.gov (United States)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  13. Precision and Accuracy of k0-NAA Method for Analysis of Multi Elements in Reference Samples

    International Nuclear Information System (INIS)

    Sri-Wardani

    2004-01-01

    Accuracy and precision of k 0 -NAA method could determine in the analysis of multi elements contained in reference samples. The analyzed results of multi elements in SRM 1633b sample were obtained with optimum results in bias of 20% but it is in a good accuracy and precision. The analyzed results of As, Cd and Zn in CCQM-P29 rice flour sample were obtained with very good result in bias of 0.5 - 5.6%. (author)

  14. A method for determination of mass per unit area inhomogeneity of thin samples in XRF analysis

    International Nuclear Information System (INIS)

    Sitko, R.; Jurczyk, J.

    1999-01-01

    The authors have presented a simple method for the determination of possible inhomogeneity of thin samples in a wavedispersive XRF analysis after previous examination of intensity distribution of exciting radiation on sample's surface. Investigations were carried out using as an example microsamples of mono- and polycrystals. Samples were prepared by digesting an analysed material directly on the substrate. The obtained results have been presented in a graphical way. (author)

  15. Comparison of alkali fusion and acid digestion methods for radiochemical separation of Uranium from dietary samples

    International Nuclear Information System (INIS)

    Kamesh Viswanathan, B.; Arunachalam, Kantha D.; Sathesh Kumar, A.; Jayakrishana, K.; Shanmugamsundaram, H.; Rao, D.D.

    2014-01-01

    Several methods exist for separation and measurement of uranium in dietary samples such as neutron activation analysis (NAA), alpha spectrometric determination, inductively coupled plasma mass spectrometry (ICP-MS) and fluorimetry. For qualitative determination of activity, NAA and alpha spectrometry are said to be superior to evaluate the isotopes of uranium ( 238 U, 234 U and 235 U). In case of alpha spectrometry, the samples have to undergo radiochemical analysis for separation from other elements for uranium detection. In our studies, uranium was determined in food matrices by acid digestion (AD) and alkali fusion (AF) methods. The recovery yield of uranium in food matrices was compared in order to get consistent yield. The average activity levels of 238 U and 234 U in food samples were calculated based on recovery yield of 232 U in the samples. The average recovery of 232 U in AD method was 22 ± 8% and in AF method, it was 14.9 ± 1.3%. The spread is more in AD method than the AF method from their mean. The lowest recovery of 232 U was found in AF method. This is due to the interference of other elements in the sample during electroplating. Experimental results showed that the uranium separation by AD method has better recovery than the AF method. The consistency in recovery of 232 U was better for AF method, which was lower than the AD method. However, overall for both the methods, the recovery can be termed as poor and need rigorous follow up studies for consistently higher recoveries (>50%) in these type of biological samples. There are reports indicating satisfactory recoveries of around 80% with 232 U as tracer in the food matrices

  16. Method of measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1980-01-01

    A novel liquid scintillation counting method of measuring the disintegration rate of a beta-emitting radionuclide is described which involves counting the sample at at least two different quench levels. (UK)

  17. Evaluation of methods for cleaning low carbon uranium metal and alloy samples

    International Nuclear Information System (INIS)

    Kirchner, K.; Dixon, M.

    1979-01-01

    Several methods for cleaning uranium samples prior to carbon analysis, using a Leco Carbon Analyzer, were evaluated. Use of Oakite Aluminum NST Cleaner followed by water and acetone rinse was found to be the best overall technique

  18. Passive sampling methods for contaminated sediments: Scientific rationale supporting use of freely dissolved concentrations

    DEFF Research Database (Denmark)

    Mayer, Philipp; Parkerton, Thomas F.; Adams, Rachel G.

    2014-01-01

    Passive sampling methods (PSMs) allow the quantification of the freely dissolved concentration (Cfree ) of an organic contaminant even in complex matrices such as sediments. Cfree is directly related to a contaminant's chemical activity, which drives spontaneous processes including diffusive upta...

  19. A method for disaggregating clay concretions and eliminating formalin smell in the processing of sediment samples

    DEFF Research Database (Denmark)

    Cedhagen, Tomas

    1989-01-01

    A complete handling procedure for processing sediment samples is described. It includes some improvements of conventional methods. The fixed sediment sample is mixed with a solution of the alkaline detergent AJAX® (Colgate-Palmolive). It is kept at 80-900 C for 20-40 min. This treatment facilitates...

  20. A sample preparation method for recovering suppressed analyte ions in MALDI TOF MS

    NARCIS (Netherlands)

    Lou, X.; Waal, de B.F.M.; Milroy, L.G.; Dongen, van J.L.J.

    2015-01-01

    In matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS), analyte signals can be substantially suppressed by other compounds in the sample. In this technical note, we describe a modified thin-layer sample preparation method that significantly reduces the analyte

  1. Modified emission-transmission method for determining trace elements in solid samples using the XRF techniques

    International Nuclear Information System (INIS)

    Poblete, V.; Alvarez, M.; Hermosilla, M.

    2000-01-01

    This is a study of an analysis of trace elements in medium thick solid samples, by the modified transmission emission method, using the energy dispersion X-ray fluorescence technique (EDXRF). The effects of absorption and reinforcement are the main disadvantages of the EDXRF technique for the quantitative analysis of bigger elements and trace elements in solid samples. The implementation of this method and its application to a variety of samples was carried out using an infinitely thick multi-element white sample that calculates the correction factors by absorbing all the analytes in the sample. The discontinuities in the masic absorption coefficients versus energies association for each element, with medium thick and homogenous samples, are analyzed and corrected. A thorough analysis of the different theoretical and test variables are proven by using real samples, including certified material with known concentration. The simplicity of the calculation method and the results obtained show the method's major precision, with possibilities for the non-destructive routine analysis of different solid samples, using the EDXRF technique (author)

  2. Selecting a sampling method to aid in vegetation management decisions in loblolly pine plantations

    Science.gov (United States)

    David R. Weise; Glenn R. Glover

    1993-01-01

    Objective methods to evaluate hardwood competition in young loblolly pine (Pinustaeda L.) plantations are not widely used in the southeastern United States. Ability of common sampling rules to accurately estimate hardwood rootstock attributes at low sampling intensities and across varying rootstock spatial distributions is unknown. Fixed area plot...

  3. Testing common stream sampling methods for broad-scale, long-term monitoring

    Science.gov (United States)

    Eric K. Archer; Brett B. Roper; Richard C. Henderson; Nick Bouwes; S. Chad Mellison; Jeffrey L. Kershner

    2004-01-01

    We evaluated sampling variability of stream habitat sampling methods used by the USDA Forest Service and the USDI Bureau of Land Management monitoring program for the upper Columbia River Basin. Three separate studies were conducted to describe the variability of individual measurement techniques, variability between crews, and temporal variation throughout the summer...

  4. Critical length sampling: a method to estimate the volume of downed coarse woody debris

    Science.gov (United States)

    G& #246; ran St& #229; hl; Jeffrey H. Gove; Michael S. Williams; Mark J. Ducey

    2010-01-01

    In this paper, critical length sampling for estimating the volume of downed coarse woody debris is presented. Using this method, the volume of downed wood in a stand can be estimated by summing the critical lengths of down logs included in a sample obtained using a relascope or wedge prism; typically, the instrument should be tilted 90° from its usual...

  5. IMPROVEMENT OF METHODS FOR HYDROBIOLOGICAL RESEARCH AND MODIFICATION OF STANDARD TOOLS FOR SAMPLE COLLECTION

    Directory of Open Access Journals (Sweden)

    M. M. Aligadjiev

    2015-01-01

    Full Text Available Aim. The paper discusses the improvement of methods of hydrobiological studies by modifying tools for plankton and benthic samples collecting. Methods. In order to improve the standard methods of hydro-biological research, we have developed tools for sampling zooplankton and benthic environment of the Caspian Sea. Results. Long-term practice of selecting hydrobiological samples in the Caspian Sea shows that it is required to complete the modernization of the sampling tools used to collect hydrobiological material. With the introduction of Azov and Black Sea invasive comb jelly named Mnemiopsis leidyi A. Agassiz to the Caspian Sea there is a need to collect plankton samples without disturbing its integrity. Tools for collecting benthic fauna do not always give a complete picture of the state of benthic ecosystems because of the lack of visual site selection for sampling. Moreover, while sampling by dredge there is a probable loss of the samples, especially in areas with difficult terrain. Conclusion. We propose to modify a small model of Upstein net (applied in shallow water to collect zooplankton samples with an upper inverted cone that will significantly improve the catchability of the net in theCaspian Sea. Bottom sampler can be improved by installing a video camera for visual inspection of the bottom topography, and use sensors to determine tilt of the dredge and the position of the valves of the bucket. 

  6. Measuring larval nematode contamination on cattle pastures: Comparing two herbage sampling methods.

    Science.gov (United States)

    Verschave, S H; Levecke, B; Duchateau, L; Vercruysse, J; Charlier, J

    2015-06-15

    Assessing levels of pasture larval contamination is frequently used to study the population dynamics of the free-living stages of parasitic nematodes of livestock. Direct quantification of infective larvae (L3) on herbage is the most applied method to measure pasture larval contamination. However, herbage collection remains labour intensive and there is a lack of studies addressing the variation induced by the sampling method and the required sample size. The aim of this study was (1) to compare two different sampling methods in terms of pasture larval count results and time required to sample, (2) to assess the amount of variation in larval counts at the level of sample plot, pasture and season, respectively and (3) to calculate the required sample size to assess pasture larval contamination with a predefined precision using random plots across pasture. Eight young stock pastures of different commercial dairy herds were sampled in three consecutive seasons during the grazing season (spring, summer and autumn). On each pasture, herbage samples were collected through both a double-crossed W-transect with samples taken every 10 steps (method 1) and four random located plots of 0.16 m(2) with collection of all herbage within the plot (method 2). The average (± standard deviation (SD)) pasture larval contamination using sampling methods 1 and 2 was 325 (± 479) and 305 (± 444)L3/kg dry herbage (DH), respectively. Large discrepancies in pasture larval counts of the same pasture and season were often seen between methods, but no significant difference (P = 0.38) in larval counts between methods was found. Less time was required to collect samples with method 2. This difference in collection time between methods was most pronounced for pastures with a surface area larger than 1 ha. The variation in pasture larval counts from samples generated by random plot sampling was mainly due to the repeated measurements on the same pasture in the same season (residual variance

  7. A New Automated Method and Sample Data Flow for Analysis of Volatile Nitrosamines in Human Urine*

    Science.gov (United States)

    Hodgson, James A.; Seyler, Tiffany H.; McGahee, Ernest; Arnstein, Stephen; Wang, Lanqing

    2016-01-01

    Volatile nitrosamines (VNAs) are a group of compounds classified as probable (group 2A) and possible (group 2B) carcinogens in humans. Along with certain foods and contaminated drinking water, VNAs are detected at high levels in tobacco products and in both mainstream and sidestream smoke. Our laboratory monitors six urinary VNAs—N-nitrosodimethylamine (NDMA), N-nitrosomethylethylamine (NMEA), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPIP), N-nitrosopyrrolidine (NPYR), and N-nitrosomorpholine (NMOR)—using isotope dilution GC-MS/MS (QQQ) for large population studies such as the National Health and Nutrition Examination Survey (NHANES). In this paper, we report for the first time a new automated sample preparation method to more efficiently quantitate these VNAs. Automation is done using Hamilton STAR™ and Caliper Staccato™ workstations. This new automated method reduces sample preparation time from 4 hours to 2.5 hours while maintaining precision (inter-run CV < 10%) and accuracy (85% - 111%). More importantly this method increases sample throughput while maintaining a low limit of detection (<10 pg/mL) for all analytes. A streamlined sample data flow was created in parallel to the automated method, in which samples can be tracked from receiving to final LIMs output with minimal human intervention, further minimizing human error in the sample preparation process. This new automated method and the sample data flow are currently applied in bio-monitoring of VNAs in the US non-institutionalized population NHANES 2013-2014 cycle. PMID:26949569

  8. Active Search on Carcasses versus Pitfall Traps: a Comparison of Sampling Methods.

    Science.gov (United States)

    Zanetti, N I; Camina, R; Visciarelli, E C; Centeno, N D

    2016-04-01

    The study of insect succession in cadavers and the classification of arthropods have mostly been done by placing a carcass in a cage, protected from vertebrate scavengers, which is then visited periodically. An alternative is to use specific traps. Few studies on carrion ecology and forensic entomology involving the carcasses of large vertebrates have employed pitfall traps. The aims of this study were to compare both sampling methods (active search on a carcass and pitfall trapping) for each coleopteran family, and to establish whether there is a discrepancy (underestimation and/or overestimation) in the presence of each family by either method. A great discrepancy was found for almost all families with some of them being more abundant in samples obtained through active search on carcasses and others in samples from traps, whereas two families did not show any bias towards a given sampling method. The fact that families may be underestimated or overestimated by the type of sampling technique highlights the importance of combining both methods, active search on carcasses and pitfall traps, in order to obtain more complete information on decomposition, carrion habitat and cadaveric families or species. Furthermore, a hypothesis advanced on the reasons for the underestimation by either sampling method showing biases towards certain families. Information about the sampling techniques indicating which would be more appropriate to detect or find a particular family is provided.

  9. Method for analysing radium in powder samples and its application to uranium prospecting

    International Nuclear Information System (INIS)

    Gong Xinxi; Hu Minzhi.

    1987-01-01

    The decayed daughter of Rn released from the power sample (soil) in a sealed bottle were collected on a piece of copper and the radium in the sample can be measured by counting α-particles with an Alphameter for uranium prospection, thus it is called the radium method. This method has many advantages, such as high sensitivity (the lowest limit of detection for radium sample per gram is 2.7 x 10 -15 g), high efficiency, low cost and easy to use. On the basis of measuring more than 700 samples taken along 20 sections in 8 deposits, the results show that the radium method is better than γ-measurement and equal to 210 Po method for the capability to descover anomalies. The author also summarizes the anomaly intensities of radium method, 210 Po method and γ-measurement respectively at the surface with deep blind ores, with or without surficial mineralization, and the figures of their profiles and the variation of Ra/ 210 Po ratios. According to the above-mentioned distinguishing features, the uranium mineralization located in deep and/or shallow parts can be distinguishd. The combined application of radium, 210 Po and γ-measurement methods may be regarded as one of the important methods used for anomaly assessment. Based on the experiments of the radium measurements with 771 stream sediments samples in an area of 100 km 2 , it is demonstrated that the radium mehtod can be used in the stages of uranium reconnaissance and prospecting

  10. Rapid-Viability PCR Method for Detection of Live, Virulent Bacillus anthracis in Environmental Samples

    OpenAIRE

    Létant, Sonia E.; Murphy, Gloria A.; Alfaro, Teneile M.; Avila, Julie R.; Kane, Staci R.; Raber, Ellen; Bunt, Thomas M.; Shah, Sanjiv R.

    2011-01-01

    In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real...

  11. Determination of element concentrations in biological reference materials by solid sampling and other analytical methods

    International Nuclear Information System (INIS)

    Schauenburg, H.; Weigert, P.

    1992-01-01

    Using solid sampling with graphite furnace atomic absorption spectrometry (GFAAS), values for cadmium, copper, lead and zinc in six biological reference materials were obtained from up to four laboratories participating in three collaborative studies. These results are compared with those obtained with other methods used in routine analysis from laboratories of official food control. Under certain conditions solid sampling with GFAAS seems to be suitable for routine analysis as well as conventional methods. (orig.)

  12. A pyrolysis/gas chromatographic method for the determination of hydrogen in solid samples

    Science.gov (United States)

    Carr, R. H.; Bustin, R.; Gibson, E. K.

    1987-01-01

    A method is described for the determination of hydrogen in solid samples. The sample is heated under vacuum after which the evolved gases are separated by gas chromatography with a helium ionization detector. The system is calibrated by injecting known amounts of hydrogen, as determined manometrically. The method, which is rapid and reliable, was checked for a variety of lunar soils; the limit of detection is about 10 ng of hydrogen.

  13. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    OpenAIRE

    Eva Tavčar; Erika Turk; Samo Kreft

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes p...

  14. Evaluation of sampling methods for Bacillus spore-contaminated HVAC filters

    OpenAIRE

    Calfee, M. Worth; Rose, Laura J.; Tufts, Jenia; Morse, Stephen; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2013-01-01

    The objective of this study was to compare an extraction-based sampling method to two vacuum-based sampling methods (vacuum sock and 37 mm cassette filter) with regards to their ability to recover Bacillus atrophaeus spores (surrogate for Bacillus anthracis) from pleated heating, ventilation, and air conditioning (HVAC) filters that are typically found in commercial and residential buildings. Electrostatic and mechanical HVAC filters were tested, both without and after loading with dust to 50...

  15. The use of physical methods for elemental analysis of ecological samples

    International Nuclear Information System (INIS)

    Kudryashov, V.I.; Zhuravleva, E.L.; Maslov, O.D.

    1996-01-01

    The possibility of the application of difference X-ray and instrumental activation methods elemental analysis of rock ice, snow, water, soil and other natural samples was investigated. The content of some elements in ice samples from the glaciers of the Pamirs-Alaj mountain system for period 1973-1984 years has been determined. The recommendations for the choice of analysis methods with the aim of the environmental control have been given. (author). 10 refs., 6 figs., 1 tab

  16. Apparatus and method for maintaining multi-component sample gas constituents in vapor phase during sample extraction and cooling

    Science.gov (United States)

    Felix, Larry Gordon; Farthing, William Earl; Irvin, James Hodges; Snyder, Todd Robert

    2010-05-11

    A dilution apparatus for diluting a gas sample. The apparatus includes a sample gas conduit having a sample gas inlet end and a diluted sample gas outlet end, and a sample gas flow restricting orifice disposed proximate the sample gas inlet end connected with the sample gas conduit and providing fluid communication between the exterior and the interior of the sample gas conduit. A diluted sample gas conduit is provided within the sample gas conduit having a mixing end with a mixing space inlet opening disposed proximate the sample gas inlet end, thereby forming an annular space between the sample gas conduit and the diluted sample gas conduit. The mixing end of the diluted sample gas conduit is disposed at a distance from the sample gas flow restricting orifice. A dilution gas source connected with the sample gas inlet end of the sample gas conduit is provided for introducing a dilution gas into the annular space, and a filter is provided for filtering the sample gas. The apparatus is particularly suited for diluting heated sample gases containing one or more condensable components.

  17. Relative efficiency of anuran sampling methods in a restinga habitat (Jurubatiba, Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    C. F. D. Rocha

    Full Text Available Studies on anurans in restinga habitats are few and, as a result, there is little information on which methods are more efficient for sampling them in this environment. Ten methods are usually used for sampling anuran communities in tropical and sub-tropical areas. In this study we evaluate which methods are more appropriate for this purpose in the restinga environment of Parque Nacional da Restinga de Jurubatiba. We analyzed six methods among those usually used for anuran samplings. For each method, we recorded the total amount of time spent (in min., the number of researchers involved, and the number of species captured. We calculated a capture efficiency index (time necessary for a researcher to capture an individual frog in order to make comparable the data obtained. Of the methods analyzed, the species inventory (9.7 min/searcher /ind.- MSI; richness = 6; abundance = 23 and the breeding site survey (9.5 MSI; richness = 4; abundance = 22 were the most efficient. The visual encounter inventory (45.0 MSI and patch sampling (65.0 MSI methods were of comparatively lower efficiency restinga, whereas the plot sampling and the pit-fall traps with drift-fence methods resulted in no frog capture. We conclude that there is a considerable difference in efficiency of methods used in the restinga environment and that the complete species inventory method is highly efficient for sampling frogs in the restinga studied and may be so in other restinga environments. Methods that are usually efficient in forested areas seem to be of little value in open restinga habitats.

  18. Relative efficiency of anuran sampling methods in a restinga habitat (Jurubatiba, Rio de Janeiro, Brazil).

    Science.gov (United States)

    Rocha, C F D; Van Sluys, M; Hatano, F H; Boquimpani-Freitas, L; Marra, R V; Marques, R V

    2004-11-01

    Studies on anurans in restinga habitats are few and, as a result, there is little information on which methods are more efficient for sampling them in this environment. Ten methods are usually used for sampling anuran communities in tropical and sub-tropical areas. In this study we evaluate which methods are more appropriate for this purpose in the restinga environment of Parque Nacional da Restinga de Jurubatiba. We analyzed six methods among those usually used for anuran samplings. For each method, we recorded the total amount of time spent (in min.), the number of researchers involved, and the number of species captured. We calculated a capture efficiency index (time necessary for a researcher to capture an individual frog) in order to make comparable the data obtained. Of the methods analyzed, the species inventory (9.7 min/searcher /ind.- MSI; richness = 6; abundance = 23) and the breeding site survey (9.5 MSI; richness = 4; abundance = 22) were the most efficient. The visual encounter inventory (45.0 MSI) and patch sampling (65.0 MSI) methods were of comparatively lower efficiency restinga, whereas the plot sampling and the pit-fall traps with drift-fence methods resulted in no frog capture. We conclude that there is a considerable difference in efficiency of methods used in the restinga environment and that the complete species inventory method is highly efficient for sampling frogs in the restinga studied and may be so in other restinga environments. Methods that are usually efficient in forested areas seem to be of little value in open restinga habitats.

  19. Surface Sampling Collection and Culture Methods for Escherichia coli in Household Environments with High Fecal Contamination.

    Science.gov (United States)

    Exum, Natalie G; Kosek, Margaret N; Davis, Meghan F; Schwab, Kellogg J

    2017-08-22

    Empiric quantification of environmental fecal contamination is an important step toward understanding the impact that water, sanitation, and hygiene interventions have on reducing enteric infections. There is a need to standardize the methods used for surface sampling in field studies that examine fecal contamination in low-income settings. The dry cloth method presented in this manuscript improves upon the more commonly used swabbing technique that has been shown in the literature to have a low sampling efficiency. The recovery efficiency of a dry electrostatic cloth sampling method was evaluated using Escherichia coli and then applied to household surfaces in Iquitos, Peru, where there is high fecal contamination and enteric infection. Side-by-side measurements were taken from various floor locations within a household at the same time over a three-month period to compare for consistency of quantification of E. coli bacteria. The dry cloth sampling method in the laboratory setting showed 105% (95% Confidence Interval: 98%, 113%) E. coli recovery efficiency off of the cloths. The field application demonstrated strong agreement of side-by-side results (Pearson correlation coefficient for dirt surfaces was 0.83 ( p samples (Pearson (0.53, p method can be utilized in households with high bacterial loads using either continuous (quantitative) or categorical (semi-quantitative) data. The standardization of this low-cost, dry electrostatic cloth sampling method can be used to measure differences between households in intervention and non-intervention arms of randomized trials.

  20. A novel heterogeneous training sample selection method on space-time adaptive processing

    Science.gov (United States)

    Wang, Qiang; Zhang, Yongshun; Guo, Yiduo

    2018-04-01

    The performance of ground target detection about space-time adaptive processing (STAP) decreases when non-homogeneity of clutter power is caused because of training samples contaminated by target-like signals. In order to solve this problem, a novel nonhomogeneous training sample selection method based on sample similarity is proposed, which converts the training sample selection into a convex optimization problem. Firstly, the existing deficiencies on the sample selection using generalized inner product (GIP) are analyzed. Secondly, the similarities of different training samples are obtained by calculating mean-hausdorff distance so as to reject the contaminated training samples. Thirdly, cell under test (CUT) and the residual training samples are projected into the orthogonal subspace of the target in the CUT, and mean-hausdorff distances between the projected CUT and training samples are calculated. Fourthly, the distances are sorted in order of value and the training samples which have the bigger value are selective preference to realize the reduced-dimension. Finally, simulation results with Mountain-Top data verify the effectiveness of the proposed method.

  1. A novel sample preparation method using rapid nonheated saponification method for the determination of cholesterol in emulsified foods.

    Science.gov (United States)

    Jeong, In-Seek; Kwak, Byung-Man; Ahn, Jang-Hyuk; Leem, Donggil; Yoon, Taehyung; Yoon, Changyong; Jeong, Jayoung; Park, Jung-Min; Kim, Jin-Man

    2012-10-01

    In this study, nonheated saponification was employed as a novel, rapid, and easy sample preparation method for the determination of cholesterol in emulsified foods. Cholesterol content was analyzed using gas chromatography with a flame ionization detector (GC-FID). The cholesterol extraction method was optimized for maximum recovery from baby food and infant formula. Under these conditions, the optimum extraction solvent was 10 mL ethyl ether per 1 to 2 g sample, and the saponification solution was 0.2 mL KOH in methanol. The cholesterol content in the products was determined to be within the certified range of certified reference materials (CRMs), NIST SRM 1544 and SRM 1849. The results of the recovery test performed using spiked materials were in the range of 98.24% to 99.45% with an relative standard devitation (RSD) between 0.83% and 1.61%. This method could be used to reduce sample pretreatment time and is expected to provide an accurate determination of cholesterol in emulsified food matrices such as infant formula and baby food. A novel, rapid, and easy sample preparation method using nonheated saponification was developed for cholesterol detection in emulsified foods. Recovery tests of CRMs were satisfactory, and the recoveries of spiked materials were accurate and precise. This method was effective and decreased the time required for analysis by 5-fold compared to the official method. © 2012 Institute of Food Technologists®

  2. Efficient free energy calculations by combining two complementary tempering sampling methods.

    Science.gov (United States)

    Xie, Liangxu; Shen, Lin; Chen, Zhe-Ning; Yang, Mingjun

    2017-01-14

    Although energy barriers can be efficiently crossed in the reaction coordinate (RC) guided sampling, this type of method suffers from identification of the correct RCs or requirements of high dimensionality of the defined RCs for a given system. If only the approximate RCs with significant barriers are used in the simulations, hidden energy barriers with small to medium height would exist in other degrees of freedom (DOFs) relevant to the target process and consequently cause the problem of insufficient sampling. To address the sampling in this so-called hidden barrier situation, here we propose an effective approach to combine temperature accelerated molecular dynamics (TAMD), an efficient RC-guided sampling method, with the integrated tempering sampling (ITS), a generalized ensemble sampling method. In this combined ITS-TAMD method, the sampling along the major RCs with high energy barriers is guided by TAMD and the sampling of the rest of the DOFs with lower but not negligible barriers is enhanced by ITS. The performance of ITS-TAMD to three systems in the processes with hidden barriers has been examined. In comparison to the standalone TAMD or ITS approach, the present hybrid method shows three main improvements. (1) Sampling efficiency can be improved at least five times even if in the presence of hidden energy barriers. (2) The canonical distribution can be more accurately recovered, from which the thermodynamic properties along other collective variables can be computed correctly. (3) The robustness of the selection of major RCs suggests that the dimensionality of necessary RCs can be reduced. Our work shows more potential applications of the ITS-TAMD method as the efficient and powerful tool for the investigation of a broad range of interesting cases.

  3. A Proteomics Sample Preparation Method for Mature, Recalcitrant Leaves of Perennial Plants

    Science.gov (United States)

    Na, Zhang; Chengying, Lao; Bo, Wang; Dingxiang, Peng; Lijun, Liu

    2014-01-01

    Sample preparation is key to the success of proteomics studies. In the present study, two sample preparation methods were tested for their suitability on the mature, recalcitrant leaves of six representative perennial plants (grape, plum, pear, peach, orange, and ramie). An improved sample preparation method was obtained: Tris and Triton X-100 were added together instead of CHAPS to the lysis buffer, and a 20% TCA-water solution and 100% precooled acetone were added after the protein extraction for the further purification of protein. This method effectively eliminates nonprotein impurities and obtains a clear two-dimensional gel electrophoresis array. The method facilitates the separation of high-molecular-weight proteins and increases the resolution of low-abundance proteins. This method provides a widely applicable and economically feasible technology for the proteomic study of the mature, recalcitrant leaves of perennial plants. PMID:25028960

  4. A proteomics sample preparation method for mature, recalcitrant leaves of perennial plants.

    Directory of Open Access Journals (Sweden)

    Deng Gang

    Full Text Available Sample preparation is key to the success of proteomics studies. In the present study, two sample preparation methods were tested for their suitability on the mature, recalcitrant leaves of six representative perennial plants (grape, plum, pear, peach, orange, and ramie. An improved sample preparation method was obtained: Tris and Triton X-100 were added together instead of CHAPS to the lysis buffer, and a 20% TCA-water solution and 100% precooled acetone were added after the protein extraction for the further purification of protein. This method effectively eliminates nonprotein impurities and obtains a clear two-dimensional gel electrophoresis array. The method facilitates the separation of high-molecular-weight proteins and increases the resolution of low-abundance proteins. This method provides a widely applicable and economically feasible technology for the proteomic study of the mature, recalcitrant leaves of perennial plants.

  5. A passive guard for low thermal conductivity measurement of small samples by the hot plate method

    International Nuclear Information System (INIS)

    Jannot, Yves; Godefroy, Justine; Degiovanni, Alain; Grigorova-Moutiers, Veneta

    2017-01-01

    Hot plate methods under steady state conditions are based on a 1D model to estimate the thermal conductivity, using measurements of the temperatures T 0 and T 1 of the two sides of the sample and of the heat flux crossing it. To be consistent with the hypothesis of the 1D heat flux, either a hot plate guarded apparatus is used, or the temperature is measured at the centre of the sample. On one hand the latter method can be used only if the ratio thickness/width of the sample is sufficiently low and on the other hand the guarded hot plate method requires large width samples (typical cross section of 0.6  ×  0.6 m 2 ). That is why both methods cannot be used for low width samples. The method presented in this paper is based on an optimal choice of the temperatures T 0 and T 1 compared to the ambient temperature T a , enabling the estimation of the thermal conductivity with a centered hot plate method, by applying the 1D heat flux model. It will be shown that these optimal values do not depend on the size or on the thermal conductivity of samples (in the range 0.015–0.2 W m −1 K −1 ), but only on T a . The experimental results obtained validate the method for several reference samples for values of the ratio thickness/width up to 0.3, thus enabling the measurement of the thermal conductivity of samples having a small cross-section, down to 0.045  ×  0.045 m 2 . (paper)

  6. A Novel Method to Handle the Effect of Uneven Sampling Effort in Biodiversity Databases

    Science.gov (United States)

    Pardo, Iker; Pata, María P.; Gómez, Daniel; García, María B.

    2013-01-01

    How reliable are results on spatial distribution of biodiversity based on databases? Many studies have evidenced the uncertainty related to this kind of analysis due to sampling effort bias and the need for its quantification. Despite that a number of methods are available for that, little is known about their statistical limitations and discrimination capability, which could seriously constrain their use. We assess for the first time the discrimination capacity of two widely used methods and a proposed new one (FIDEGAM), all based on species accumulation curves, under different scenarios of sampling exhaustiveness using Receiver Operating Characteristic (ROC) analyses. Additionally, we examine to what extent the output of each method represents the sampling completeness in a simulated scenario where the true species richness is known. Finally, we apply FIDEGAM to a real situation and explore the spatial patterns of plant diversity in a National Park. FIDEGAM showed an excellent discrimination capability to distinguish between well and poorly sampled areas regardless of sampling exhaustiveness, whereas the other methods failed. Accordingly, FIDEGAM values were strongly correlated with the true percentage of species detected in a simulated scenario, whereas sampling completeness estimated with other methods showed no relationship due to null discrimination capability. Quantifying sampling effort is necessary to account for the uncertainty in biodiversity analyses, however, not all proposed methods are equally reliable. Our comparative analysis demonstrated that FIDEGAM was the most accurate discriminator method in all scenarios of sampling exhaustiveness, and therefore, it can be efficiently applied to most databases in order to enhance the reliability of biodiversity analyses. PMID:23326357

  7. Evaluation of sampling methods for Bacillus spore-contaminated HVAC filters.

    Science.gov (United States)

    Calfee, M Worth; Rose, Laura J; Tufts, Jenia; Morse, Stephen; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2014-01-01

    The objective of this study was to compare an extraction-based sampling method to two vacuum-based sampling methods (vacuum sock and 37mm cassette filter) with regards to their ability to recover Bacillus atrophaeus spores (surrogate for Bacillus anthracis) from pleated heating, ventilation, and air conditioning (HVAC) filters that are typically found in commercial and residential buildings. Electrostatic and mechanical HVAC filters were tested, both without and after loading with dust to 50% of their total holding capacity. The results were analyzed by one-way ANOVA across material types, presence or absence of dust, and sampling device. The extraction method gave higher relative recoveries than the two vacuum methods evaluated (p≤0.001). On average, recoveries obtained by the vacuum methods were about 30% of those achieved by the extraction method. Relative recoveries between the two vacuum methods were not significantly different (p>0.05). Although extraction methods yielded higher recoveries than vacuum methods, either HVAC filter sampling approach may provide a rapid and inexpensive mechanism for understanding the extent of contamination following a wide-area biological release incident. Published by Elsevier B.V.

  8. Solvent extraction method for rapid separation of strontium-90 in milk and food samples

    International Nuclear Information System (INIS)

    Hingorani, S.B.; Sathe, A.P.

    1991-01-01

    A solvent extraction method, using tributyl phosphate, for rapid separation of strontium-90 in milk and other food samples has been presented in this report in view of large number of samples recieved after Chernobyl accident for checking radioactive contamination. The earlier nitration method in use for the determination of 90 Sr through its daughter 90 Y takes over two weeks for analysis of a sample. While by this extraction method it takes only 4 to 5 hours for sample analysis. Complete estimation including initial counting can be done in a single day. The chemical recovery varies between 80-90% compared to nitration method which is 65-80%. The purity of the method has been established by following the decay of yttrium-90 separated. Some of the results obtained by adopting this chemical method for food analysis are included. The method is, thus, found to be rapid and convenient for accurate estimation of strontium-90 in milk and food samples. (author). 2 tabs., 1 fig

  9. Shear Strength of Remoulding Clay Samples Using Different Methods of Moulding

    Science.gov (United States)

    Norhaliza, W.; Ismail, B.; Azhar, A. T. S.; Nurul, N. J.

    2016-07-01

    Shear strength for clay soil was required to determine the soil stability. Clay was known as a soil with complex natural formations and very difficult to obtain undisturbed samples at the site. The aim of this paper was to determine the unconfined shear strength of remoulded clay on different methods in moulding samples which were proctor compaction, hand operated soil compacter and miniature mould methods. All the samples were remoulded with the same optimum moisture content (OMC) and density that were 18% and 1880 kg/m3 respectively. The unconfined shear strength results of remoulding clay soils for proctor compaction method was 289.56kPa with the strain 4.8%, hand operated method was 261.66kPa with the strain 4.4% and miniature mould method was 247.52kPa with the strain 3.9%. Based on the proctor compaction method, the reduction percentage of unconfined shear strength of remoulded clay soil of hand operated method was 9.66%, and for miniature mould method was 14.52%. Thus, because there was no significant difference of reduction percentage of unconfined shear strength between three different methods, so it can be concluded that remoulding clay by hand operated method and miniature mould method were accepted and suggested to perform remoulding clay samples by other future researcher. However for comparison, the hand operated method was more suitable to form remoulded clay sample in term of easiness, saving time and less energy for unconfined shear strength determination purposes.

  10. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    Science.gov (United States)

    Van Berkel, Gary J; Kertesz, Vilmos; Ovchinnikova, Olga S

    2013-08-27

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  11. A fast learning method for large scale and multi-class samples of SVM

    Science.gov (United States)

    Fan, Yu; Guo, Huiming

    2017-06-01

    A multi-class classification SVM(Support Vector Machine) fast learning method based on binary tree is presented to solve its low learning efficiency when SVM processing large scale multi-class samples. This paper adopts bottom-up method to set up binary tree hierarchy structure, according to achieved hierarchy structure, sub-classifier learns from corresponding samples of each node. During the learning, several class clusters are generated after the first clustering of the training samples. Firstly, central points are extracted from those class clusters which just have one type of samples. For those which have two types of samples, cluster numbers of their positive and negative samples are set respectively according to their mixture degree, secondary clustering undertaken afterwards, after which, central points are extracted from achieved sub-class clusters. By learning from the reduced samples formed by the integration of extracted central points above, sub-classifiers are obtained. Simulation experiment shows that, this fast learning method, which is based on multi-level clustering, can guarantee higher classification accuracy, greatly reduce sample numbers and effectively improve learning efficiency.

  12. PhyloChip™ microarray comparison of sampling methods used for coral microbial ecology

    Science.gov (United States)

    Kellogg, Christina A.; Piceno, Yvette M.; Tom, Lauren M.; DeSantis, Todd Z.; Zawada, David G.; Andersen, Gary L.

    2012-01-01

    Interest in coral microbial ecology has been increasing steadily over the last decade, yet standardized methods of sample collection still have not been defined. Two methods were compared for their ability to sample coral-associated microbial communities: tissue punches and foam swabs, the latter being less invasive and preferred by reef managers. Four colonies of star coral, Montastraea annularis, were sampled in the Dry Tortugas National Park (two healthy and two with white plague disease). The PhyloChip™ G3 microarray was used to assess microbial community structure of amplified 16S rRNA gene sequences. Samples clustered based on methodology rather than coral colony. Punch samples from healthy and diseased corals were distinct. All swab samples clustered closely together with the seawater control and did not group according to the health state of the corals. Although more microbial taxa were detected by the swab method, there is a much larger overlap between the water control and swab samples than punch samples, suggesting some of the additional diversity is due to contamination from water absorbed by the swab. While swabs are useful for noninvasive studies of the coral surface mucus layer, these results show that they are not optimal for studies of coral disease.

  13. Culture methods of allograft musculoskeletal tissue samples in Australian bacteriology laboratories.

    Science.gov (United States)

    Varettas, Kerry

    2013-12-01

    Samples of allograft musculoskeletal tissue are cultured by bacteriology laboratories to determine the presence of bacteria and fungi. In Australia, this testing is performed by 6 TGA-licensed clinical bacteriology laboratories with samples received from 10 tissue banks. Culture methods of swab and tissue samples employ a combination of solid agar and/or broth media to enhance micro-organism growth and maximise recovery. All six Australian laboratories receive Amies transport swabs and, except for one laboratory, a corresponding biopsy sample for testing. Three of the 6 laboratories culture at least one allograft sample directly onto solid agar. Only one laboratory did not use a broth culture for any sample received. An international literature review found that a similar combination of musculoskeletal tissue samples were cultured onto solid agar and/or broth media. Although variations of allograft musculoskeletal tissue samples, culture media and methods are used in Australian and international bacteriology laboratories, validation studies and method evaluations have challenged and supported their use in recovering fungi and aerobic and anaerobic bacteria.

  14. Laboratory Studies on Surface Sampling of Bacillus anthracis Contamination: Summary, Gaps, and Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Hu, Rebecca

    2011-11-28

    This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.

  15. Sampling methods for pasture, soil and deposition for radioactivity emergency preparedness in the Nordic countries

    International Nuclear Information System (INIS)

    Isaksson, M.

    2002-01-01

    The aim of this work was to compare sampling techniques for pasture, soil and deposition, planned for radioactivity surveillance in emergency situations in the Nordic countries. The basis of the survey was a questionnaire, sent to radiation protection authorities and laboratories. Sampling of pasture is performed with a cutting height between 1 and 5 cm above the ground from an area of about 1 m 2 . The sampling plots are usually randomly positioned. Soil samples, 3 to 20 cores in various patterns, are generally taken by a corer of varying diameter. For deposition sampling, precipitation collectors of different sizes are used. When comparing results, the differences between laboratories should be borne in mind so that proper corrections can be made. It is, however, important to consider that, especially in an emergency situation, the use of standardised methods may worsen the results if these methods are not part of the daily work. (orig.)

  16. Pi sampling: a methodical and flexible approach to initial macromolecular crystallization screening

    International Nuclear Information System (INIS)

    Gorrec, Fabrice; Palmer, Colin M.; Lebon, Guillaume; Warne, Tony

    2011-01-01

    Pi sampling, derived from the incomplete factorial approach, is an effort to maximize the diversity of macromolecular crystallization conditions and to facilitate the preparation of 96-condition initial screens. The Pi sampling method is derived from the incomplete factorial approach to macromolecular crystallization screen design. The resulting ‘Pi screens’ have a modular distribution of a given set of up to 36 stock solutions. Maximally diverse conditions can be produced by taking into account the properties of the chemicals used in the formulation and the concentrations of the corresponding solutions. The Pi sampling method has been implemented in a web-based application that generates screen formulations and recipes. It is particularly adapted to screens consisting of 96 different conditions. The flexibility and efficiency of Pi sampling is demonstrated by the crystallization of soluble proteins and of an integral membrane-protein sample

  17. Recent advances in sample preparation techniques and methods of sulfonamides detection - A review.

    Science.gov (United States)

    Dmitrienko, Stanislava G; Kochuk, Elena V; Apyari, Vladimir V; Tolmacheva, Veronika V; Zolotov, Yury A

    2014-11-19

    Sulfonamides (SAs) have been the most widely used antimicrobial drugs for more than 70 years, and their residues in foodstuffs and environmental samples pose serious health hazards. For this reason, sensitive and specific methods for the quantification of these compounds in numerous matrices have been developed. This review intends to provide an updated overview of the recent trends over the past five years in sample preparation techniques and methods for detecting SAs. Examples of the sample preparation techniques, including liquid-liquid and solid-phase extraction, dispersive liquid-liquid microextraction and QuEChERS, are given. Different methods of detecting the SAs present in food and feed and in environmental, pharmaceutical and biological samples are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Note: A simple image processing based fiducial auto-alignment method for sample registration.

    Science.gov (United States)

    Robertson, Wesley D; Porto, Lucas R; Ip, Candice J X; Nantel, Megan K T; Tellkamp, Friedjof; Lu, Yinfei; Miller, R J Dwayne

    2015-08-01

    A simple method for the location and auto-alignment of sample fiducials for sample registration using widely available MATLAB/LabVIEW software is demonstrated. The method is robust, easily implemented, and applicable to a wide variety of experiment types for improved reproducibility and increased setup speed. The software uses image processing to locate and measure the diameter and center point of circular fiducials for distance self-calibration and iterative alignment and can be used with most imaging systems. The method is demonstrated to be fast and reliable in locating and aligning sample fiducials, provided here by a nanofabricated array, with accuracy within the optical resolution of the imaging system. The software was further demonstrated to register, load, and sample the dynamically wetted array.

  19. Method validation to determine total alpha beta emitters in water samples using LSC

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.; Al-akel, B.; Saaid, S.

    2006-06-01

    In this work a method was validated to determine gross alpha and beta emitters in water samples using liquid scintillation counter. 200 ml of water from each sample were evaporated to 20 ml and 8 ml of them were mixed with 12 ml of the suitable cocktail to be measured by liquid scintillation counter Wallac Winspectral 1414. The lower detection limit by this method (LDL) was 0.33 DPM for total alpha emitters and 1.3 DPM for total beta emitters. and the reproducibility limit was (± 2.32 DPM) and (±1.41 DPM) for total alpha and beta emitters respectively, and the repeatability limit was (±2.19 DPM) and (±1.11 DPM) for total alpha and beta emitters respectively. The method is easy and fast because of the simple preparation steps and the large number of samples that can be measured at the same time. In addition, many real samples and standard samples were analyzed by the method and showed accurate results so it was concluded that the method can be used with various water samples. (author)

  20. Phylogenetic representativeness: a new method for evaluating taxon sampling in evolutionary studies

    Directory of Open Access Journals (Sweden)

    Passamonti Marco

    2010-04-01

    Full Text Available Abstract Background Taxon sampling is a major concern in phylogenetic studies. Incomplete, biased, or improper taxon sampling can lead to misleading results in reconstructing evolutionary relationships. Several theoretical methods are available to optimize taxon choice in phylogenetic analyses. However, most involve some knowledge about the genetic relationships of the group of interest (i.e., the ingroup, or even a well-established phylogeny itself; these data are not always available in general phylogenetic applications. Results We propose a new method to assess taxon sampling developing Clarke and Warwick statistics. This method aims to measure the "phylogenetic representativeness" of a given sample or set of samples and it is based entirely on the pre-existing available taxonomy of the ingroup, which is commonly known to investigators. Moreover, our method also accounts for instability and discordance in taxonomies. A Python-based script suite, called PhyRe, has been developed to implement all analyses we describe in this paper. Conclusions We show that this method is sensitive and allows direct discrimination between representative and unrepresentative samples. It is also informative about the addition of taxa to improve taxonomic coverage of the ingroup. Provided that the investigators' expertise is mandatory in this field, phylogenetic representativeness makes up an objective touchstone in planning phylogenetic studies.

  1. A simple high performance liquid chromatography method for analyzing paraquat in soil solution samples.

    Science.gov (United States)

    Ouyang, Ying; Mansell, Robert S; Nkedi-Kizza, Peter

    2004-01-01

    A high performance liquid chromatography (HPLC) method with UV detection was developed to analyze paraquat (1,1'-dimethyl-4,4'-dipyridinium dichloride) herbicide content in soil solution samples. The analytical method was compared with the liquid scintillation counting (LSC) method using 14C-paraquat. Agreement obtained between the two methods was reasonable. However, the detection limit for paraquat analysis was 0.5 mg L(-1) by the HPLC method and 0.05 mg L(-1) by the LSC method. The LSC method was, therefore, 10 times more precise than the HPLC method for solution concentrations less than 1 mg L(-1). In spite of the high detection limit, the UC (nonradioactive) HPLC method provides an inexpensive and environmentally safe means for determining paraquat concentration in soil solution compared with the 14C-LSC method.

  2. Cytotoxicity of Light-Cured Dental Materials according to Different Sample Preparation Methods

    Directory of Open Access Journals (Sweden)

    Myung-Jin Lee

    2017-03-01

    Full Text Available Dental light-cured resins can undergo different degrees of polymerization when applied in vivo. When polymerization is incomplete, toxic monomers may be released into the oral cavity. The present study assessed the cytotoxicity of different materials, using sample preparation methods that mirror clinical conditions. Composite and bonding resins were used and divided into four groups according to sample preparation method: uncured; directly cured samples, which were cured after being placed on solidified agar; post-cured samples were polymerized before being placed on agar; and “removed unreacted layer” samples had their oxygen-inhibition layer removed after polymerization. Cytotoxicity was evaluated using an agar diffusion test, MTT assay, and confocal microscopy. Uncured samples were the most cytotoxic, while removed unreacted layer samples were the least cytotoxic (p < 0.05. In the MTT assay, cell viability increased significantly in every group as the concentration of the extracts decreased (p < 0.05. Extracts from post-cured and removed unreacted layer samples of bonding resin were less toxic than post-cured and removed unreacted layer samples of composite resin. Removal of the oxygen-inhibition layer resulted in the lowest cytotoxicity. Clinicians should remove unreacted monomers on the resin surface immediately after restoring teeth with light-curing resin to improve the restoration biocompatibility.

  3. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  4. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  5. Assessment of reagent effectiveness and preservation methods for equine faecal samples

    Directory of Open Access Journals (Sweden)

    Eva Vavrouchova

    2015-03-01

    Full Text Available The aim of our study was to identify the most suitable flotation solution and effective preservation method for the examination of equine faeces samples using the FLOTAC technique. Samples from naturally infected horses were transported to the laboratory andanalysed accordingly. The sample from each horse was homogenized and divided into four parts: one was frozen, another two were preserved in different reagents such as sodium acetate-acetic-acid–formalin (SAF or 5% formalin.The last part was examined as a fresh sample in three different flotation solutions (Sheather´s solution, sodium chloride and sodium nitrate solution, all with a specific gravity 1.200. The preserved samples were examined in the period from 14 to21days after collection. According to our results, the sucrose solution was the most suitable flotation solution for fresh samples (small strongyle egg per gram was 706 compared to 360 in sodium chlorid and 507 in sodium nitrate and the sodium nitrate solution was the most efficient for the preserved samples (egg per gram was 382 compared to 295 in salt solution and 305 in sucrose solution. Freezing appears to be the most effective method of sample preservation, resulting in minimal damage to fragile strongyle eggs and therefore it is the most simple and effective preservation method for the examination of large numbers of faecal samples without the necessity of examining them all within 48 hours of collection. Deep freezing as a preservation method for equine faeces samples has not, according to our knowledge, been yet published.

  6. Differences of detection efficiency among several nasal swab samples simulated for nuclear emergency accident

    International Nuclear Information System (INIS)

    Fukutsu, Kumiko; Yamada, Yuji; Kurihara, Osamu; Akashi, Makoto; Momose, Takumaro; Miyabe, Kenjiro

    2008-01-01

    At nuclear emergency accident such as inhalation intake of alpha nuclide, an indispensable nasal swab method has not been used for the precise internal dose estimation. One of the reasons is uncertainty in its radiation measurement, so that precise measurement with alpha spectrometry was examined for filter samples simulating nasal swab. It was confirmed that the alpha spectrometry made possible the distinction between solution and particulate in addition to the nuclide identification. The alpha activity in swab sample was precisely evaluated only when the detection efficiency was determined considering the self-absorption with filter fibers. Another big problem of wiping efficiency in nasal swabbing is still remain, but this study certainly raised the usefulness of the nasal swab method for rapid response in emergency. (author)

  7. Reproducibility of measurement of the environmental carbon-14 samples prepared by the gel suspension method

    International Nuclear Information System (INIS)

    Ohura, Hirotaka; Wakabayashi, Genichiro; Nakamura, Kouji; Okai, Tomio; Matoba, Masaru; Kakiuchi, Hideki; Momoshima, Noriyuki; Kawamura, Hidehisa.

    1997-01-01

    Simple liquid scintillation counting technique for the assay of 14 C in the environment was developed. This technique was done by using gel suspension method, in which sample preparation is very simple and requires no special equipments. The reproducibility of this technique was considered and it was shown that the gel suspension method had enough reproducibility to monitor the environmental 14 C. (author)

  8. 40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false What are the sampling and testing... commercially available diesel fuel which meets the applicable industry consensus and federal regulatory...) Qualification of test methods approved by voluntary consensus-based standards bodies. Any standard test method...

  9. 43 CFR 11.64 - Injury determination phase-testing and sampling methods.

    Science.gov (United States)

    2010-10-01

    ... Institute for Occupational Safety and Health, the American Society for Testing and Materials, and the American Public Health Association. (iii) Methods selected for air sampling and analysis shall be methods... stresses simulated; (B) How the model approximates the geohydrological framework of the assessment area; (C...

  10. A simple and rapid cultural method for detection of Enterobacter sakazakii in environmental samples

    NARCIS (Netherlands)

    Guillaume-Gentil, O.; Sonnard, V.; Kandhai, M.C.; Marugg, J.; Joosten, H.

    2005-01-01

    A method was developed to detect and identify Enterobacter sakazakii in environmental samples. The method is based on selective enrichment at 45 ± 0.5°C in lauryl sulfate tryptose broth supplemented with 0.5 M NaCl and 10 mg/liter vancomycin (mLST) for 22 to 24 h followed by streaking on tryptone

  11. Estimating sample size for a small-quadrat method of botanical ...

    African Journals Online (AJOL)

    Reports the results of a study conducted to determine an appropriate sample size for a small-quadrat method of botanical survey for application in the Mixed Bushveld of South Africa. Species density and grass density were measured using a small-quadrat method in eight plant communities in the Nylsvley Nature Reserve.

  12. Sample preparation method for the combined extraction of ethyl glucuronide and drugs of abuse in hair.

    Science.gov (United States)

    Meier, Ulf; Briellmann, Thomas; Scheurer, Eva; Dussy, Franz

    2018-04-01

    Often in hair analysis, a small hair sample is available while the analysis of a multitude of structurally diverse substances with different concentration ranges is demanded. The analysis of the different substances often requires different sample preparation methods, increasing the amount of required hair sample. When segmental hair analysis is necessary, the amount of hair sample needed is further increased. Therefore, the required sample amount for a full analysis can quickly exceed what is available. To combat this problem, a method for the combined hair sample preparation using a single extraction procedure for analysis of ethyl glucuronide with liquid chromatography-multistage fragmentation mass spectrometry/multiple reaction monitoring (LC-MS 3 /MRM) and common drugs of abuse with LC-MRM was developed. The combined sample preparation is achieved by separating ethyl glucuronide from the drugs of abuse into separate extracts by fractionation in the solid-phase extraction step during sample clean-up. A full validation for all substances for the parameters selectivity, linearity, limit of detection, limit of quantification, accuracy, precision, matrix effects, and recovery was successfully completed. The following drugs of abuse were included in the method: Amphetamine; methamphetamine; 3,4-methylenedioxy-N-methylamphetamine (MDMA); 3,4-methylenedioxyamphetamine (MDA); 3,4-methylenedioxy-N-ethylamphetamine (MDE); morphine; 6-monoacetylmorphine; codeine; acetylcodeine; cocaine; benzoylecgonine; norcocaine; cocaethylene; methadone; 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and methylphenidate. In conclusion, as only 1 sample preparation is needed with 1 aliquot of hair, the presented sample preparation allows an optimal analysis of both ethyl glucuronide and of the drugs of abuse, even when the sample amount is a limiting factor. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Method for measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    1977-01-01

    A method of measuring the distintegration rate of a beta-emitting radionuclide in a liquid sample by counting at least two differently quenched versions of the sample. In each counting operation the sample is counted in the presence of and in the absence of a standard radioactive source. A pulse height (PH) corresponding to a unique point on the pulse height spectrum generated in the presence of the standard is determined. A zero threshold sample count rate (CPM) is derived by counting the sample once in a counting window having a zero threshold lower limit. Normalized values of the measured pulse heights (PH) are developed and correlated with the corresponding counts (CPM) to determine the pulse count for a normalized pulse height value of zero and hence the sample disintegration rate

  14. System and method for liquid extraction electrospray-assisted sample transfer to solution for chemical analysis

    Science.gov (United States)

    Kertesz, Vilmos; Van Berkel, Gary J.

    2016-07-12

    A system for sampling a surface includes a surface sampling probe comprising a solvent liquid supply conduit and a distal end, and a sample collector for suspending a sample collection liquid adjacent to the distal end of the probe. A first electrode provides a first voltage to solvent liquid at the distal end of the probe. The first voltage produces a field sufficient to generate electrospray plume at the distal end of the probe. A second electrode provides a second voltage and is positioned to produce a plume-directing field sufficient to direct the electrospray droplets and ions to the suspended sample collection liquid. The second voltage is less than the first voltage in absolute value. A voltage supply system supplies the voltages to the first electrode and the second electrode. The first electrode can apply the first voltage directly to the solvent liquid. A method for sampling for a surface is also disclosed.

  15. Method of measuring the disinteration rate of beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1977-01-01

    A method of measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample by counting at least two differently quenched versions of the sample is described. In each counting operation the sample is counted in the presence of and in the absence of a standard radioactive source. A pulse height (PH) corresponding to a unique point on the pulse height spectrum generated in the presence of the standard is determined. A zero threshold sample count rate (CPM) is derived by counting the sample once in a counting window having a zero threshold lower limit. Normalized values of the measured pulse heights (PH) are developed and correlated with the corresponding pulse counts (CPM) to determine the pulse count for a normalized pulse height value of zero and hence the sample disintegration rate

  16. Rapid separation method for {sup 237}Np and Pu isotopes in large soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Sherrod L., E-mail: sherrod.maxwell@srs.go [Savannah River Nuclear Solutions, LLC, Building 735-B, Aiken, SC 29808 (United States); Culligan, Brian K.; Noyes, Gary W. [Savannah River Nuclear Solutions, LLC, Building 735-B, Aiken, SC 29808 (United States)

    2011-07-15

    A new rapid method for the determination of {sup 237}Np and Pu isotopes in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for large soil samples. The new soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using these two simple precipitations with high chemical recoveries and effective removal of interferences. Vacuum box technology and rapid flow rates are used to reduce analytical time.

  17. Comparison of sample preparation methods for reliable plutonium and neptunium urinalysis using automatic extraction chromatography

    DEFF Research Database (Denmark)

    Qiao, Jixin; Xu, Yihong; Hou, Xiaolin

    2014-01-01

    This paper describes improvement and comparison of analytical methods for simultaneous determination of trace-level plutonium and neptunium in urine samples by inductively coupled plasma mass spectrometry (ICP-MS). Four sample pre-concentration techniques, including calcium phosphate, iron......), it endows urinalysis methods with better reliability and repeatability compared with co-precipitation techniques. In view of the applicability of different pre-concentration techniques proposed previously in the literature, the main challenge behind relevant method development is pointed to be the release...

  18. A NEW METHOD FOR NON DESTRUCTIVE ESTIMATION OF Jc IN YBaCuO CERAMIC SAMPLES

    Directory of Open Access Journals (Sweden)

    Giancarlo Cordeiro Costa

    2014-12-01

    Full Text Available This work presents a new method for estimation of Jc as a bulk characteristic of YBCO blocks. The experimental magnetic interaction force between a SmCo permanent magnet and a YBCO block was compared to finite element method (FEM simulations results, allowing us to search a best fitting value to the critical current of the superconducting sample. As FEM simulations were based on Bean model , the critical current density was taken as an unknown parameter. This is a non destructive estimation method. since there is no need of breaking even a little piece of the sample for analysis.

  19. Comparison of acid leachate and fusion methods to determine plutonium and americium in environmental samples

    International Nuclear Information System (INIS)

    Smith, L.L.; Markun, F.; TenKate, T.

    1992-06-01

    The Analytical Chemistry Laboratory at Argonne National Laboratory performs radiochemical analyses for a wide variety of sites within the Department of Energy complex. Since the chemical history of the samples may vary drastically from site to site, the effectiveness of any analytical technique may also vary. This study compares a potassium fluoride-pyrosulfate fusion technique with an acid leachate method. Both normal and high-fired soils and vegetation samples were analyzed for both americium and plutonium. Results show both methods work well, except for plutonium in high-fired soils. Here the fusion method provides higher accuracy

  20. OPTIMAL METHOD FOR PREPARATION OF SILICATE ROCK SAMPLES FOR ANALYTICAL PURPOSES

    Directory of Open Access Journals (Sweden)

    Maja Vrkljan

    2004-12-01

    Full Text Available The purpose of this study was to determine an optimal dissolution method for silicate rock samples for further analytical purposes. Analytical FAAS method of determining cobalt, chromium, copper, nickel, lead and zinc content in gabbro sample and geochemical standard AGV-1 has been applied for verification. Dissolution in mixtures of various inorganic acids has been tested, as well as Na2CO3 fusion technique. The results obtained by different methods have been compared and dissolution in the mixture of HNO3 + HF has been recommended as optimal.

  1. A generalized transmission method for gamma-efficiency determinations in soil samples

    International Nuclear Information System (INIS)

    Bolivar, J.P.; Garcia-Tenorio, R.; Garcia-Leon, M.

    1994-01-01

    In this paper, a generalization of the γ-ray transmission method which is useful for measurements on soil samples, for example, is presented. The correction factor, f, is given, which is a function of the apparent density of the soil and the γ-ray energy. With this method, the need for individual determinations of f, for each energy and apparent soil density is avoided. Although the method has been developed for soils, the general philosophy can be applied to other sample matrices, such as water or vegetables for example. (author)

  2. 40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...

  3. Development of sampling method and chromatographic analysis of volatile organic compounds emitted from human skin.

    Science.gov (United States)

    Grabowska-Polanowska, Beata; Miarka, Przemysław; Skowron, Monika; Sułowicz, Joanna; Wojtyna, Katarzyna; Moskal, Karolina; Śliwka, Ireneusz

    2017-10-01

    The studies on volatile organic compounds emitted from skin are an interest for chemists, biologists and physicians due to their role in development of different scientific areas, including medical diagnostics, forensic medicine and the perfume design. This paper presents a proposal of two sampling methods applied to skin odor collection: the first one uses a bag of cellulose film, the second one, using cellulose sachets filled with active carbon. Volatile organic compounds were adsorbed on carbon sorbent, removed via thermal desorption and analyzed using gas chromatograph with mass spectrometer. The first sampling method allowed identification of more compounds (52) comparing to the second one (30). Quantitative analyses for acetone, butanal, pentanal and hexanal were done. The skin odor sampling method using a bag of cellulose film, allowed the identification of many more compounds when compared with the method using a sachet filled with active carbon.

  4. A faster sample preparation method for determination of polonium-210 in fish

    International Nuclear Information System (INIS)

    Sadi, B.B.; Jing Chen; Kochermin, Vera; Godwin Tung; Sorina Chiorean

    2016-01-01

    In order to facilitate Health Canada’s study on background radiation levels in country foods, an in-house radio-analytical method has been developed for determination of polonium-210 ( 210 Po) in fish samples. The method was validated by measurement of 210 Po in a certified reference material. It was also evaluated by comparing 210 Po concentrations in a number of fish samples by another method. The in-house method offers faster sample dissolution using an automated digestion system compared to currently used wet-ashing on a hot plate. It also utilizes pre-packed Sr-resin® cartridges for rapid and reproducible separation of 210 Po versus time-consuming manually packed Sr-resin® columns. (author)

  5. Determination of radiocaesium in agriculture-related water samples containing suspended solids using gelling method

    International Nuclear Information System (INIS)

    Matsunami, Hisaya; Shin, Moono; Takahashi, Yoshihiko; Shinano, Takuro; Kitajima, Shiori; Tsuchiya, Takashi

    2015-01-01

    After the TEPCO Fukushima Dai-ichi Nuclear Power Plant accident in 2011, the radiocaesium, which flowed into the paddy fields via irrigation water, have been widely investigated. When the concentration of radiocaesium in the water samples containing suspended solids were directly measured using a high purity germanium detector with a 2 L marinelli beaker, the radiocaesium concentration might be overestimated due to the sedimentation of the suspended solids during the measurement time. In fact, the values obtained by the direct method were higher than those obtained by the filtering method and/or the gelling method in most of the agriculture-related water samples. We concluded that the gelling method using sodium polyacrylate can be widely adapted for the analysis of the total radiocaesium in the agriculture-related water samples because of its many advantage such as simple preparation procedure, accurate analysis values, excellent long-term stability of geometry and low operating cost. (author)

  6. The application of variable sampling method in the audit testing of insurance companies' premium income

    Directory of Open Access Journals (Sweden)

    Jovković Biljana

    2012-12-01

    Full Text Available The aim of this paper is to present the procedure of audit sampling using the variable sampling methods for conducting the tests of income from insurance premiums in insurance company 'Takovo'. Since the incomes from the insurance premiums from vehicle insurance and third-party vehicle insurance have the dominant share of the insurance company's income, the application of this method will be shown in the audit examination of these incomes - incomes from VI and TPVI premiums. For investigating the applicability of these methods in testing the income of other insurance companies, we shall implement the method of variable sampling in the audit testing of the premium income from the three leading insurance companies in Serbia, 'Dunav', 'DDOR' and 'Delta Generali' Insurance.

  7. Computational methods and modeling. 1. Sampling a Position Uniformly in a Trilinear Hexahedral Volume

    International Nuclear Information System (INIS)

    Urbatsch, Todd J.; Evans, Thomas M.; Hughes, H. Grady

    2001-01-01

    Monte Carlo particle transport plays an important role in some multi-physics simulations. These simulations, which may additionally involve deterministic calculations, typically use a hexahedral or tetrahedral mesh. Trilinear hexahedrons are attractive for physics calculations because faces between cells are uniquely defined, distance-to-boundary calculations are deterministic, and hexahedral meshes tend to require fewer cells than tetrahedral meshes. We discuss one aspect of Monte Carlo transport: sampling a position in a tri-linear hexahedron, which is made up of eight control points, or nodes, and six bilinear faces, where each face is defined by four non-coplanar nodes in three-dimensional Cartesian space. We derive, code, and verify the exact sampling method and propose an approximation to it. Our proposed approximate method uses about one-third the memory and can be twice as fast as the exact sampling method, but we find that its inaccuracy limits its use to well-behaved hexahedrons. Daunted by the expense of the exact method, we propose an alternate approximate sampling method. First, calculate beforehand an approximate volume for each corner of the hexahedron by taking one-eighth of the volume of an imaginary parallelepiped defined by the corner node and the three nodes to which it is directly connected. For the sampling, assume separability in the parameters, and sample each parameter, in turn, from a linear pdf defined by the sum of the four corner volumes at each limit (-1 and 1) of the parameter. This method ignores the quadratic portion of the pdf, but it requires less storage, has simpler sampling, and needs no extra, on-the-fly calculations. We simplify verification by designing tests that consist of one or more cells that entirely fill a unit cube. Uniformly sampling complicated cells that fill a unit cube will result in uniformly sampling the unit cube. Unit cubes are easily analyzed. The first problem has four wedges (or tents, or A frames) whose

  8. Comparison of three mycobacterial DNA extraction methods from extrapulmonary samples for PCR assay

    Directory of Open Access Journals (Sweden)

    Khandaker Shadia

    2012-01-01

    Full Text Available Sensitivity of the molecular diagnostic tests of extrapulmonary tuberculosis largely depends upon the efficiency of DNA extraction methods. The objective of our study was to compare three methods of extracting DNA of Mycobacterium tuberculosis for testing by polymerase chain reaction. All three methods; heating, heating with sonication and addition of lysis buffer with heating and sonication were implicated on 20 extrapulmonary samples. PCR positivity was 2 (10%, 4 (20% and 7 (35% in the samples extracted by heating, heat+sonication and heat+sonication+lysis buffer method respectively. Of the extraction methods evaluated, maximum PCR positive results were achieved by combined heat, sonication and lysis buffer method which can be applied in routine clinical practice. Ibrahim Med. Coll. J. 2012; 6(1: 9-11

  9. Comparison of vapor sampling system (VSS) and in situ vapor sampling (ISVS) methods on Tanks C-107, BY-108, and S-102

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Edwards, J.A.; Evans, J.C.

    1996-05-01

    The objective of this report is to evaluate the equivalency of two methods used to sample nonradioactive gases and vapors in the Hanford Site high-level waste tank headspaces. In addition to the comparison of the two sampling methods, the effects of an in-line fine particle filter on sampling results are also examined to determine whether results are adversely affected by its presence. This report discusses data from a January 1996 sampling

  10. Rapid-viability PCR method for detection of live, virulent Bacillus anthracis in environmental samples.

    Science.gov (United States)

    Létant, Sonia E; Murphy, Gloria A; Alfaro, Teneile M; Avila, Julie R; Kane, Staci R; Raber, Ellen; Bunt, Thomas M; Shah, Sanjiv R

    2011-09-01

    In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis, in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples.

  11. A simple method to adapt time sampling of the analog signal

    International Nuclear Information System (INIS)

    Kalinin, Yu.G.; Martyanov, I.S.; Sadykov, Kh.; Zastrozhnova, N.N.

    2004-01-01

    In this paper we briefly describe the time sampling method, which is adapted to the speed of the signal change. Principally, this method is based on a simple idea--the combination of discrete integration with differentiation of the analog signal. This method can be used in nuclear electronics research into the characteristics of detectors and the shape of the pulse signal, pulse and transitive characteristics of inertial systems of processing of signals, etc

  12. A method to measure the diffusion coefficient by neutron wave propagation for limited samples

    International Nuclear Information System (INIS)

    Woznicka, U.

    1986-03-01

    A study has been made of the use of the neutron wave and pulse propagation method for measurement of thermal neutron diffusion parameters. Earlier works an homogenous and heterogeneous media are reviewed. A new method is sketched for the determination of the diffusion coefficient for samples of limited size. The principle is to place a relatively thin slab of the material between two blocks of a medium with known properties. The advantages and disadvantages of the method are discussed. (author)

  13. Measurements of linear attenuation coefficients of irregular shaped samples by two media method

    International Nuclear Information System (INIS)

    Singh, Sukhpal; Kumar, Ashok; Thind, Kulwant Singh; Mudahar, Gurmel S.

    2008-01-01

    The linear attenuation coefficient values of regular and irregular shaped flyash materials have been measured without knowing the thickness of a sample using a new technique namely 'two media method'. These values have also been measured with a standard gamma ray transmission method and obtained theoretically with winXCOM computer code. From the comparison it is reported that the two media method has given accurate results of attenuation coefficients of flyash materials

  14. A comparison of fitness-case sampling methods for genetic programming

    Science.gov (United States)

    Martínez, Yuliana; Naredo, Enrique; Trujillo, Leonardo; Legrand, Pierrick; López, Uriel

    2017-11-01

    Genetic programming (GP) is an evolutionary computation paradigm for automatic program induction. GP has produced impressive results but it still needs to overcome some practical limitations, particularly its high computational cost, overfitting and excessive code growth. Recently, many researchers have proposed fitness-case sampling methods to overcome some of these problems, with mixed results in several limited tests. This paper presents an extensive comparative study of four fitness-case sampling methods, namely: Interleaved Sampling, Random Interleaved Sampling, Lexicase Selection and Keep-Worst Interleaved Sampling. The algorithms are compared on 11 symbolic regression problems and 11 supervised classification problems, using 10 synthetic benchmarks and 12 real-world data-sets. They are evaluated based on test performance, overfitting and average program size, comparing them with a standard GP search. Comparisons are carried out using non-parametric multigroup tests and post hoc pairwise statistical tests. The experimental results suggest that fitness-case sampling methods are particularly useful for difficult real-world symbolic regression problems, improving performance, reducing overfitting and limiting code growth. On the other hand, it seems that fitness-case sampling cannot improve upon GP performance when considering supervised binary classification.

  15. Method for rapid screening analysis of Sr-90 in edible plant samples collected near Fukushima, Japan

    International Nuclear Information System (INIS)

    Amano, Hikaru; Sakamoto, Hideaki; Shiga, Norikatsu; Suzuki, Kaori

    2016-01-01

    A screening method for measuring 90 Sr in edible plant samples by focusing on 90 Y in equilibrium with 90 Sr is reported. 90 Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. The dissolved oxalate precipitate was loaded on an extraction chromatography resin, and the 90 Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. 90 Sr ( 90 Y) concentration was determined in plant samples collected near the damaged Fukushima Daiichi Nuclear Power Plants with this method. - Highlights: • A screening method for measuring 90 Sr in edible plant samples by focusing on 90 Y in equilibrium with 90 Sr is reported. • 90 Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. • The dissolved oxalate precipitate was loaded on an extraction chromatography resin. • 90 Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. • 90 Sr ( 90 Y) concentration was determined in edible plant samples collected near the damaged Fukushima Daiichi NPPs with this method.

  16. Sparse feature learning for instrument identification: Effects of sampling and pooling methods.

    Science.gov (United States)

    Han, Yoonchang; Lee, Subin; Nam, Juhan; Lee, Kyogu

    2016-05-01

    Feature learning for music applications has recently received considerable attention from many researchers. This paper reports on the sparse feature learning algorithm for musical instrument identification, and in particular, focuses on the effects of the frame sampling techniques for dictionary learning and the pooling methods for feature aggregation. To this end, two frame sampling techniques are examined that are fixed and proportional random sampling. Furthermore, the effect of using onset frame was analyzed for both of proposed sampling methods. Regarding summarization of the feature activation, a standard deviation pooling method is used and compared with the commonly used max- and average-pooling techniques. Using more than 47 000 recordings of 24 instruments from various performers, playing styles, and dynamics, a number of tuning parameters are experimented including the analysis frame size, the dictionary size, and the type of frequency scaling as well as the different sampling and pooling methods. The results show that the combination of proportional sampling and standard deviation pooling achieve the best overall performance of 95.62% while the optimal parameter set varies among the instrument classes.

  17. A Comparison between Three Methods of Language Sampling: Freeplay, Narrative Speech and Conversation

    Directory of Open Access Journals (Sweden)

    Yasser Rezapour

    2011-10-01

    Full Text Available Objectives: The spontaneous language sample analysis is an important part of the language assessment protocol. Language samples give us useful information about how children use language in the natural situations of daily life. The purpose of this study was to compare Conversation, Freeplay, and narrative speech in aspects of Mean Length of Utterance (MLU, Type-token ratio (TTR, and the number of utterances. Methods: By cluster sampling method, a total of 30 Semnanian five-year-old boys with normal speech and language development were selected from the active kindergartens in Semnan city. Conversation, Freeplay, and narrative speech were three applied language sample elicitation methods to obtain 15 minutes of children’s spontaneous language samples. Means for MLU, TTR, and the number of utterances are analyzed by dependent ANOVA. Results: The result showed no significant difference in number of elicited utterances among these three language sampling methods. Narrative speech elicited longer MLU than freeplay and conversation, and compared to freeplay and narrative speech, conversation elicited higher TTR. Discussion: Results suggest that in the clinical assessment of the Persian-language children, it is better to use narrative speech to elicit longer MLU and to use conversation to elicit higher TTR.

  18. Brachytherapy dose-volume histogram computations using optimized stratified sampling methods

    International Nuclear Information System (INIS)

    Karouzakis, K.; Lahanas, M.; Milickovic, N.; Giannouli, S.; Baltas, D.; Zamboglou, N.

    2002-01-01

    A stratified sampling method for the efficient repeated computation of dose-volume histograms (DVHs) in brachytherapy is presented as used for anatomy based brachytherapy optimization methods. The aim of the method is to reduce the number of sampling points required for the calculation of DVHs for the body and the PTV. From the DVHs are derived the quantities such as Conformity Index COIN and COIN integrals. This is achieved by using partial uniform distributed sampling points with a density in each region obtained from a survey of the gradients or the variance of the dose distribution in these regions. The shape of the sampling regions is adapted to the patient anatomy and the shape and size of the implant. For the application of this method a single preprocessing step is necessary which requires only a few seconds. Ten clinical implants were used to study the appropriate number of sampling points, given a required accuracy for quantities such as cumulative DVHs, COIN indices and COIN integrals. We found that DVHs of very large tissue volumes surrounding the PTV, and also COIN distributions, can be obtained using a factor of 5-10 times smaller the number of sampling points in comparison with uniform distributed points

  19. Automated PCR setup for forensic casework samples using the Normalization Wizard and PCR Setup robotic methods.

    Science.gov (United States)

    Greenspoon, S A; Sykes, K L V; Ban, J D; Pollard, A; Baisden, M; Farr, M; Graham, N; Collins, B L; Green, M M; Christenson, C C

    2006-12-20

    Human genome, pharmaceutical and research laboratories have long enjoyed the application of robotics to performing repetitive laboratory tasks. However, the utilization of robotics in forensic laboratories for processing casework samples is relatively new and poses particular challenges. Since the quantity and quality (a mixture versus a single source sample, the level of degradation, the presence of PCR inhibitors) of the DNA contained within a casework sample is unknown, particular attention must be paid to procedural susceptibility to contamination, as well as DNA yield, especially as it pertains to samples with little biological material. The Virginia Department of Forensic Science (VDFS) has successfully automated forensic casework DNA extraction utilizing the DNA IQ(trade mark) System in conjunction with the Biomek 2000 Automation Workstation. Human DNA quantitation is also performed in a near complete automated fashion utilizing the AluQuant Human DNA Quantitation System and the Biomek 2000 Automation Workstation. Recently, the PCR setup for casework samples has been automated, employing the Biomek 2000 Automation Workstation and Normalization Wizard, Genetic Identity version, which utilizes the quantitation data, imported into the software, to create a customized automated method for DNA dilution, unique to that plate of DNA samples. The PCR Setup software method, used in conjunction with the Normalization Wizard method and written for the Biomek 2000, functions to mix the diluted DNA samples, transfer the PCR master mix, and transfer the diluted DNA samples to PCR amplification tubes. Once the process is complete, the DNA extracts, still on the deck of the robot in PCR amplification strip tubes, are transferred to pre-labeled 1.5 mL tubes for long-term storage using an automated method. The automation of these steps in the process of forensic DNA casework analysis has been accomplished by performing extensive optimization, validation and testing of the

  20. Rapid filtration separation-based sample preparation method for Bacillus spores in powdery and environmental matrices.

    Science.gov (United States)

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T; Bastien, Martine; Stewart, Gale; Leblanc, Eric; Sato, Sachiko; Bergeron, Michel G

    2012-03-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.

  1. A rapid sample screening method for authenticity control of whiskey using capillary electrophoresis with online preconcentration.

    Science.gov (United States)

    Heller, Melina; Vitali, Luciano; Oliveira, Marcone Augusto Leal; Costa, Ana Carolina O; Micke, Gustavo Amadeu

    2011-07-13

    The present study aimed to develop a methodology using capillary electrophoresis for the determination of sinapaldehyde, syringaldehyde, coniferaldehyde, and vanillin in whiskey samples. The main objective was to obtain a screening method to differentiate authentic samples from seized samples suspected of being false using the phenolic aldehydes as chemical markers. The optimized background electrolyte was composed of 20 mmol L(-1) sodium tetraborate with 10% MeOH at pH 9.3. The study examined two kinds of sample stacking, using a long-end injection mode: normal sample stacking (NSM) and sample stacking with matrix removal (SWMR). In SWMR, the optimized injection time of the samples was 42 s (SWMR42); at this time, no matrix effects were observed. Values of r were >0.99 for the both methods. The LOD and LOQ were better than 100 and 330 mg mL(-1) for NSM and better than 22 and 73 mg L(-1) for SWMR. The CE-UV reliability in the aldehyde analysis in the real sample was compared statistically with LC-MS/MS methodology, and no significant differences were found, with a 95% confidence interval between the methodologies.

  2. Error baseline rates of five sample preparation methods used to characterize RNA virus populations.

    Directory of Open Access Journals (Sweden)

    Jeffrey R Kugelman

    Full Text Available Individual RNA viruses typically occur as populations of genomes that differ slightly from each other due to mutations introduced by the error-prone viral polymerase. Understanding the variability of RNA virus genome populations is critical for understanding virus evolution because individual mutant genomes may gain evolutionary selective advantages and give rise to dominant subpopulations, possibly even leading to the emergence of viruses resistant to medical countermeasures. Reverse transcription of virus genome populations followed by next-generation sequencing is the only available method to characterize variation for RNA viruses. However, both steps may lead to the introduction of artificial mutations, thereby skewing the data. To better understand how such errors are introduced during sample preparation, we determined and compared error baseline rates of five different sample preparation methods by analyzing in vitro transcribed Ebola virus RNA from an artificial plasmid-based system. These methods included: shotgun sequencing from plasmid DNA or in vitro transcribed RNA as a basic "no amplification" method, amplicon sequencing from the plasmid DNA or in vitro transcribed RNA as a "targeted" amplification method, sequence-independent single-primer amplification (SISPA as a "random" amplification method, rolling circle reverse transcription sequencing (CirSeq as an advanced "no amplification" method, and Illumina TruSeq RNA Access as a "targeted" enrichment method. The measured error frequencies indicate that RNA Access offers the best tradeoff between sensitivity and sample preparation error (1.4-5 of all compared methods.

  3. Fast acquisition of multidimensional NMR spectra of solids and mesophases using alternative sampling methods.

    Science.gov (United States)

    Lesot, Philippe; Kazimierczuk, Krzysztof; Trébosc, Julien; Amoureux, Jean-Paul; Lafon, Olivier

    2015-11-01

    Unique information about the atom-level structure and dynamics of solids and mesophases can be obtained by the use of multidimensional nuclear magnetic resonance (NMR) experiments. Nevertheless, the acquisition of these experiments often requires long acquisition times. We review here alternative sampling methods, which have been proposed to circumvent this issue in the case of solids and mesophases. Compared to the spectra of solutions, those of solids and mesophases present some specificities because they usually display lower signal-to-noise ratios, non-Lorentzian line shapes, lower spectral resolutions and wider spectral widths. We highlight herein the advantages and limitations of these alternative sampling methods. A first route to accelerate the acquisition time of multidimensional NMR spectra consists in the use of sparse sampling schemes, such as truncated, radial or random sampling ones. These sparsely sampled datasets are generally processed by reconstruction methods differing from the Discrete Fourier Transform (DFT). A host of non-DFT methods have been applied for solids and mesophases, including the G-matrix Fourier transform, the linear least-square procedures, the covariance transform, the maximum entropy and the compressed sensing. A second class of alternative sampling consists in departing from the Jeener paradigm for multidimensional NMR experiments. These non-Jeener methods include Hadamard spectroscopy as well as spatial or orientational encoding of the evolution frequencies. The increasing number of high field NMR magnets and the development of techniques to enhance NMR sensitivity will contribute to widen the use of these alternative sampling methods for the study of solids and mesophases in the coming years. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Comparison of vapor sampling system (VSS) and in situ vapor sampling (ISVS) methods on Tanks C-107, BY-108, and S-102. Revision 1

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Edwards, J.A.; Evans, J.C.

    1996-08-01

    This report discusses comparison tests for two methods of collecting vapor samples from the Hanford Site high-level radioactive waste tank headspaces. The two sampling methods compared are the truck-mounted vapor sampling system (VSS) and the cart-mounted in-situ vapor sampling (ISVS). Three tanks were sampled by both the VSS and ISVS methods from the same access risers within the same 8-hour period. These tanks have diverse headspace compositions and they represent the highest known level of several key vapor analytes

  5. A Simple Sampling Method for Estimating the Accuracy of Large Scale Record Linkage Projects.

    Science.gov (United States)

    Boyd, James H; Guiver, Tenniel; Randall, Sean M; Ferrante, Anna M; Semmens, James B; Anderson, Phil; Dickinson, Teresa

    2016-05-17

    Record linkage techniques allow different data collections to be brought together to provide a wider picture of the health status of individuals. Ensuring high linkage quality is important to guarantee the quality and integrity of research. Current methods for measuring linkage quality typically focus on precision (the proportion of incorrect links), given the difficulty of measuring the proportion of false negatives. The aim of this work is to introduce and evaluate a sampling based method to estimate both precision and recall following record linkage. In the sampling based method, record-pairs from each threshold (including those below the identified cut-off for acceptance) are sampled and clerically reviewed. These results are then applied to the entire set of record-pairs, providing estimates of false positives and false negatives. This method was evaluated on a synthetically generated dataset, where the true match status (which records belonged to the same person) was known. The sampled estimates of linkage quality were relatively close to actual linkage quality metrics calculated for the whole synthetic dataset. The precision and recall measures for seven reviewers were very consistent with little variation in the clerical assessment results (overall agreement using the Fleiss Kappa statistics was 0.601). This method presents as a possible means of accurately estimating matching quality and refining linkages in population level linkage studies. The sampling approach is especially important for large project linkages where the number of record pairs produced may be very large often running into millions.

  6. An adaptive sampling method for variable-fidelity surrogate models using improved hierarchical kriging

    Science.gov (United States)

    Hu, Jiexiang; Zhou, Qi; Jiang, Ping; Shao, Xinyu; Xie, Tingli

    2018-01-01

    Variable-fidelity (VF) modelling methods have been widely used in complex engineering system design to mitigate the computational burden. Building a VF model generally includes two parts: design of experiments and metamodel construction. In this article, an adaptive sampling method based on improved hierarchical kriging (ASM-IHK) is proposed to refine the improved VF model. First, an improved hierarchical kriging model is developed as the metamodel, in which the low-fidelity model is varied through a polynomial response surface function to capture the characteristics of a high-fidelity model. Secondly, to reduce local approximation errors, an active learning strategy based on a sequential sampling method is introduced to make full use of the already required information on the current sampling points and to guide the sampling process of the high-fidelity model. Finally, two numerical examples and the modelling of the aerodynamic coefficient for an aircraft are provided to demonstrate the approximation capability of the proposed approach, as well as three other metamodelling methods and two sequential sampling methods. The results show that ASM-IHK provides a more accurate metamodel at the same simulation cost, which is very important in metamodel-based engineering design problems.

  7. Prediction of two-sample 99mTc-diethylene triamine pentaacetic acid plasma clearance from single-sample method

    International Nuclear Information System (INIS)

    Zuo Li; Ma Ying-Chun; Wang Mei; Zhang Chun-Li; Wang Rong-Fu; Wang Hai-Yan

    2005-01-01

    The objective of this study was to develop an equation to predict dual plasma sample method (DPSM) 99m Tc-diethylene triamine pentaacetic acid ( 99m Tc-DTPA) plasma clearance from single plasma sample method (SPSM), and to clarify the condition in which DPSM can be substituted by SPSM in measurement of glomerular filtration rate (GFR). Patients with chronic kidney disease (CKD) were selected. Watson modified Christensen and Groth equation was used to calculate 99m Tc-DTPA plasma clearance by SPSM (sGFR). The equation recommended by the Nephrourology Committee of the Society of Nuclear Medicine was used to calculate 99m Tc-DTPA plasma clearance by DPSM (tGFR) in each patient. The difference between sGFR and tGFR was expressed as percent of the average of these two methods, and tGFR was predicted from sGFR. Plasma creatinine was measured by the kinetic picrate method, and GFR estimated by abbreviated modification of diet in renal disease (MDRD) equation (aGFR) and Cockcroft-Gault equation (cGFR) were evaluated as criteria in selection of DPSM and SPSM. Three hundred and sixty-nine patients with CKD were selected (208 male and 161 female). The average age and body weight were 51.4±15.5 years and 67.2±12.5 kg, respectively. The causes of CKD were glomerular disease, renal arterial stenosis, chronic tubulointerstitial disease, and other causes or causes unknown. The average tGFR was 62.9±36.5 ml/min/1.73 m 2 , ranging from 1-180 ml/min/1.73 m 2 . sGFR was significantly correlated with tGFR (r=0.9194, p 2 ; in contrast, then tGFR was±30 ml/min/1.73 m 2 , the difference was constant (-1.1%, 95% confidence interval -18.3%, 16.1%), and tGFR could be predicted from sGFR using the equation: predicted tGFR (ml/min/1.73 m 2 )=7 4244+0.7318 x sGFR+0.0022 x sGFR 2 (n=299, r 2 =0.9428, p 2 , the diagnostic sensitivity of a cut off value of aGFR=45 ml/min/1.73 m 2 was 91.8%, and recommended as a criterion in the selection of DPSM and SPSM. When GFR ≥30 ml/min/1.73 m 2 , t

  8. Detection of protozoa in water samples by formalin/ether concentration method.

    Science.gov (United States)

    Lora-Suarez, Fabiana; Rivera, Raul; Triviño-Valencia, Jessica; Gomez-Marin, Jorge E

    2016-09-01

    Methods to detect protozoa in water samples are expensive and laborious. We evaluated the formalin/ether concentration method to detect Giardia sp., Cryptosporidium sp. and Toxoplasma in water. In order to test the properties of the method, we spiked water samples with different amounts of each protozoa (0, 10 and 50 cysts or oocysts) in a volume of 10 L of water. Immunofluorescence assay was used for detection of Giardia and Cryptosporidium. Toxoplasma oocysts were identified by morphology. The mean percent of recovery in 10 repetitions of the entire method, in 10 samples spiked with ten parasites and read by three different observers, were for Cryptosporidium 71.3 ± 12, for Giardia 63 ± 10 and for Toxoplasma 91.6 ± 9 and the relative standard deviation of the method was of 17.5, 17.2 and 9.8, respectively. Intraobserver variation as measured by intraclass correlation coefficient, was fair for Toxoplasma, moderate for Cryptosporidium and almost perfect for Giardia. The method was then applied in 77 samples of raw and drinkable water in three different plant of water treatment. Cryptosporidium was found in 28 of 77 samples (36%) and Giardia in 31 of 77 samples (40%). Theses results identified significant differences in treatment process to reduce the presence of Giardia and Cryptosporidium. In conclusion, the formalin ether method to concentrate protozoa in water is a new alternative for low resources countries, where is urgently need to monitor and follow the presence of theses protozoa in drinkable water. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Experimental estimation of migration and transfer of organic substances from consumer articles to cotton wipes: Evaluation of underlying mechanisms.

    Science.gov (United States)

    Clausen, Per Axel; Spaan, Suzanne; Brouwer, Derk H; Marquart, Hans; le Feber, Maaike; Engel, Roel; Geerts, Lieve; Jensen, Keld Alstrup; Kofoed-Sørensen, Vivi; Hansen, Brian; De Brouwere, Katleen

    2016-01-01

    The aim of this work was to identify the key mechanisms governing transport of organic chemical substances from consumer articles to cotton wipes. The results were used to establish a mechanistic model to improve assessment of dermal contact exposure. Four types of PVC flooring, 10 types of textiles and one type of inkjet printed paper were used to establish the mechanisms and model. Kinetic extraction studies in methanol demonstrated existence of matrix diffusion and indicated the presence of a substance surface layer on some articles. Consequently, the proposed substance transfer model considers mechanical transport from a surface film and matrix diffusion in an article with a known initial total substance concentration. The estimated chemical substance transfer values to cotton wipes were comparable to the literature data (relative transfer ∼ 2%), whereas relative transfer efficiencies from spiked substrates were high (∼ 50%). For consumer articles, high correlation (r(2)=0.92) was observed between predicted and measured transfer efficiencies, but concentrations were overpredicted by a factor of 10. Adjusting the relative transfer from about 50% used in the model to about 2.5% removed overprediction. Further studies are required to confirm the model for generic use.

  10. A method to combine non-probability sample data with probability sample data in estimating spatial means of environmental variables

    NARCIS (Netherlands)

    Brus, D.J.; Gruijter, de J.J.

    2003-01-01

    In estimating spatial means of environmental variables of a region from data collected by convenience or purposive sampling, validity of the results can be ensured by collecting additional data through probability sampling. The precision of the pi estimator that uses the probability sample can be

  11. Standardization of method to determine 241Pu in urine samples by liquid scintillation analyzer

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Rao, D.D.; Yadav, J.R.; Baburajan, A.

    2015-01-01

    As a part of radiation protection programme, occupational workers of fuel reprocessing plant are checked for internal contamination by analyzing urine samples periodically. Urine samples are analyzed to determine 239+240 Pu and 238 Pu by using standard conventional method and are counted by alpha spectrometry. 241 Pu is also one of the contaminant present in the urine sample of radiation workers. It is a low beta emitter with E max 21 keV. A methodology for the determination of this nuclide was standardized by using radiochemical analysis followed by Liquid Scintillation Counting. The method was tested and found suitable for the determination of 241 Pu in urine sample for the assessment of Committed Effective Dose (CED). (author)

  12. An economic passive sampling method to detect particulate pollutants using magnetic measurements.

    Science.gov (United States)

    Cao, Liwan; Appel, Erwin; Hu, Shouyun; Ma, Mingming

    2015-10-01

    Identifying particulate matter (PM) emitted from industrial processes into the atmosphere is an important issue in environmental research. This paper presents a passive sampling method using simple artificial samplers that maintains the advantage of bio-monitoring, but overcomes some of its disadvantages. The samplers were tested in a heavily polluted area (Linfen, China) and compared to results from leaf samples. Spatial variations of magnetic susceptibility from artificial passive samplers and leaf samples show very similar patterns. Scanning electron microscopy suggests that the collected PM are mostly in the range of 2-25 μm; frequent occurrence of spherical shape indicates industrial combustion dominates PM emission. Magnetic properties around power plants show different features than other plants. This sampling method provides a suitable and economic tool for semi-quantifying temporal and spatial distribution of air quality; they can be installed in a regular grid and calibrate the weight of PM. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Automatic segmentation of Leishmania parasite in microscopic images using a modified CV level set method

    Science.gov (United States)

    Farahi, Maria; Rabbani, Hossein; Talebi, Ardeshir; Sarrafzadeh, Omid; Ensafi, Shahab

    2015-12-01

    Visceral Leishmaniasis is a parasitic disease that affects liver, spleen and bone marrow. According to World Health Organization report, definitive diagnosis is possible just by direct observation of the Leishman body in the microscopic image taken from bone marrow samples. We utilize morphological and CV level set method to segment Leishman bodies in digital color microscopic images captured from bone marrow samples. Linear contrast stretching method is used for image enhancement and morphological method is applied to determine the parasite regions and wipe up unwanted objects. Modified global and local CV level set methods are proposed for segmentation and a shape based stopping factor is used to hasten the algorithm. Manual segmentation is considered as ground truth to evaluate the proposed method. This method is tested on 28 samples and achieved 10.90% mean of segmentation error for global model and 9.76% for local model.

  14. Preparation of Samples for Leaf Architecture Studies, A Method for Mounting Cleared Leaves

    Directory of Open Access Journals (Sweden)

    Alejandra Vasco

    2014-09-01

    Full Text Available Premise of the study: Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. Methods and Results: Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. Conclusions: The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration.

  15. Preparation of samples for leaf architecture studies, a method for mounting cleared leaves1

    Science.gov (United States)

    Vasco, Alejandra; Thadeo, Marcela; Conover, Margaret; Daly, Douglas C.

    2014-01-01

    • Premise of the study: Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. • Methods and Results: Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. • Conclusions: The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration. PMID:25225627

  16. Rapid, sensitive and cost effective method for isolation of viral DNA from feacal samples of dogs

    Directory of Open Access Journals (Sweden)

    Savi.

    2010-06-01

    Full Text Available A simple method for viral DNA extraction using chelex resin was developed. The method used was eco-friendly and cost effective compared to other methods such as phenol chloroform method which use health hazardous organic reagents. Further, a polymerase chain reaction (PCR based detection of canine parvovirus (CPV using primers from conserved region of VP2 gene was developed. To increase the sensitivity and specificity of reaction, nested PCR was designed. PCR reaction was optimized to amplify 747bp product of VP2 gene. The assay can be completed in few hours and doesn’t need hazardous chemicals. Thus, the sample preparation using chelating resin along with nested PCR seems to be a sensitive, specific and practical method for the detection of CPV in diarrhoeal feacal samples. [Vet. World 2010; 3(3.000: 105-106

  17. Comparison of the acetyl bromide spectrophotometric method with other analytical lignin methods for determining lignin concentration in forage samples.

    Science.gov (United States)

    Fukushima, Romualdo S; Hatfield, Ronald D

    2004-06-16

    Present analytical methods to quantify lignin in herbaceous plants are not totally satisfactory. A spectrophotometric method, acetyl bromide soluble lignin (ABSL), has been employed to determine lignin concentration in a range of plant materials. In this work, lignin extracted with acidic dioxane was used to develop standard curves and to calculate the derived linear regression equation (slope equals absorptivity value or extinction coefficient) for determining the lignin concentration of respective cell wall samples. This procedure yielded lignin values that were different from those obtained with Klason lignin, acid detergent acid insoluble lignin, or permanganate lignin procedures. Correlations with in vitro dry matter or cell wall digestibility of samples were highest with data from the spectrophotometric technique. The ABSL method employing as standard lignin extracted with acidic dioxane has the potential to be employed as an analytical method to determine lignin concentration in a range of forage materials. It may be useful in developing a quick and easy method to predict in vitro digestibility on the basis of the total lignin content of a sample.

  18. Transformation-cost time-series method for analyzing irregularly sampled data.

    Science.gov (United States)

    Ozken, Ibrahim; Eroglu, Deniz; Stemler, Thomas; Marwan, Norbert; Bagci, G Baris; Kurths, Jürgen

    2015-06-01

    Irregular sampling of data sets is one of the challenges often encountered in time-series analysis, since traditional methods cannot be applied and the frequently used interpolation approach can corrupt the data and bias the subsequence analysis. Here we present the TrAnsformation-Cost Time-Series (TACTS) method, which allows us to analyze irregularly sampled data sets without degenerating the quality of the data set. Instead of using interpolation we consider time-series segments and determine how close they are to each other by determining the cost needed to transform one segment into the following one. Using a limited set of operations-with associated costs-to transform the time series segments, we determine a new time series, that is our transformation-cost time series. This cost time series is regularly sampled and can be analyzed using standard methods. While our main interest is the analysis of paleoclimate data, we develop our method using numerical examples like the logistic map and the Rössler oscillator. The numerical data allows us to test the stability of our method against noise and for different irregular samplings. In addition we provide guidance on how to choose the associated costs based on the time series at hand. The usefulness of the TACTS method is demonstrated using speleothem data from the Secret Cave in Borneo that is a good proxy for paleoclimatic variability in the monsoon activity around the maritime continent.

  19. Transformation-cost time-series method for analyzing irregularly sampled data

    Science.gov (United States)

    Ozken, Ibrahim; Eroglu, Deniz; Stemler, Thomas; Marwan, Norbert; Bagci, G. Baris; Kurths, Jürgen

    2015-06-01

    Irregular sampling of data sets is one of the challenges often encountered in time-series analysis, since traditional methods cannot be applied and the frequently used interpolation approach can corrupt the data and bias the subsequence analysis. Here we present the TrAnsformation-Cost Time-Series (TACTS) method, which allows us to analyze irregularly sampled data sets without degenerating the quality of the data set. Instead of using interpolation we consider time-series segments and determine how close they are to each other by determining the cost needed to transform one segment into the following one. Using a limited set of operations—with associated costs—to transform the time series segments, we determine a new time series, that is our transformation-cost time series. This cost time series is regularly sampled and can be analyzed using standard methods. While our main interest is the analysis of paleoclimate data, we develop our method using numerical examples like the logistic map and the Rössler oscillator. The numerical data allows us to test the stability of our method against noise and for different irregular samplings. In addition we provide guidance on how to choose the associated costs based on the time series at hand. The usefulness of the TACTS method is demonstrated using speleothem data from the Secret Cave in Borneo that is a good proxy for paleoclimatic variability in the monsoon activity around the maritime continent.

  20. Optimization of fecal cytology in the dog: comparison of three sampling methods.

    Science.gov (United States)

    Frezoulis, Petros S; Angelidou, Elisavet; Diakou, Anastasia; Rallis, Timoleon S; Mylonakis, Mathios E

    2017-09-01

    Dry-mount fecal cytology (FC) is a component of the diagnostic evaluation of gastrointestinal diseases. There is limited information on the possible effect of the sampling method on the cytologic findings of healthy dogs or dogs admitted with diarrhea. We aimed to: (1) establish sampling method-specific expected values of selected cytologic parameters (isolated or clustered epithelial cells, neutrophils, lymphocytes, macrophages, spore-forming rods) in clinically healthy dogs; (2) investigate if the detection of cytologic abnormalities differs among methods in dogs admitted with diarrhea; and (3) investigate if there is any association between FC abnormalities and the anatomic origin (small- or large-bowel diarrhea) or the chronicity of diarrhea. Sampling with digital examination (DE), rectal scraping (RS), and rectal lavage (RL) was prospectively assessed in 37 healthy and 34 diarrheic dogs. The median numbers of isolated ( p = 0.000) or clustered ( p = 0.002) epithelial cells, and of lymphocytes ( p = 0.000), differed among the 3 methods in healthy dogs. In the diarrheic dogs, the RL method was the least sensitive in detecting neutrophils, and isolated or clustered epithelial cells. Cytologic abnormalities were not associated with the origin or the chronicity of diarrhea. Sampling methods differed in their sensitivity to detect abnormalities in FC; DE or RS may be of higher sensitivity compared to RL. Anatomic origin or chronicity of diarrhea do not seem to affect the detection of cytologic abnormalities.