  1. An Experimental and Analytical Evaluation of Wall And Window Retrofit Configurations: Supporting the Residential Retrofit Best Practices Guide

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, Therese K [ORNL; Petrie, Thomas [ORNL; Kosny, Jan [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL; Hulvey, Kimberly D [ORNL

    2007-11-01

    A Retrofit Best Practices Guide was developed to encourage homeowners to consider energy conservation issues whenever they modify their siding or windows. In support of this guide, an experimental program was implemented to measure the performance of a number of possible wall siding and window retrofit configurations. Both thermal and air-leakage measurements were made for a 2.4 x 2.4 m (8 x 8 ft) wall section with and without a 0.9 x 1.2 m (3 x 4 ft) window. The windows tested were previously well-characterized at a dedicated window test facility. A computer model was also used to provide information for the Best Practices Guide. The experimental data for walls and windows were used in conjunction with this model to estimate the total annual energy savings for several typical houses in a number of different locations.

  2. High Performance Window Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Desjarlais, Andre Omer [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2013-12-01

    The US Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) and Traco partnered to develop high-performance windows for commercial building that are cost-effective. The main performance requirement for these windows was that they needed to have an R-value of at least 5 ft2∙ F∙h/Btu. This project seeks to quantify the potential energy savings from installing these windows in commercial buildings that are at least 20 years old. To this end, we are conducting evaluations at a two-story test facility that is representative of a commercial building from the 1980s, and are gathering measurements on the performance of its windows before and after double-pane, clear-glazed units are upgraded with R5 windows. Additionally, we will use these data to calibrate EnergyPlus models that we will allow us to extrapolate results to other climates. Findings from this project will provide empirical data on the benefits from high-performance windows, which will help promote their adoption in new and existing commercial buildings. This report describes the experimental setup, and includes some of the field and simulation results.

  3. Impact of three window configurations on daylight conditions

    DEFF Research Database (Denmark)

    Dubois, Marie-Claude; Sørensen, Karl Grau; Traberg-Borup, Steen

    The report describes the results of a pilot study on daylight conditions in simple rooms of residential buildings. As a tool for the analyses the Radiance Lighting Simulating System was used to simulate one room with three different window configurations, a vertical window, a dormer window......, and a roof window. The simulations were performed for overcast sky conditions and under one sunny sky, for two different times of the day. The study shows that the window configuration affects the daylight conditions (distribution and intensity) significantly. The roof window results in a higher (average......) daylight factor on a horizontal plane, i.e. more than twice as high compared with the vertical window, and more than triple as high compared with the dormer window....

  4. Windows PowerShell desired state configuration revealed

    CERN Document Server

    Chaganti, Ravikanth

    2014-01-01

    Desired State Configuration (DSC) is a powerful new configuration management platform that makes it easier than ever to perform cross-platform configuration management of your infrastructure, whether on-premise or in the cloud. DSC provides the management platform and Application Programming Interface (API) that can be used with any programming language. Windows PowerShell Desired State Configuration Revealed will take you through this new technology from start to finish and demonstrates the DSC interfaces through Windows PowerShell. DSC allows you to manage target devices by simply declarin

  5. Flexible transparent aerogels as window retrofitting films and optical elements with tunable birefringence

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Qingkun; Frazier, Allister W.; Zhao, Xinpeng; De La Cruz, Joshua A.; Hess, Andrew J.; Yang, Ronggui; Smalyukh, Ivan I.

    2018-06-01

    Experimental realization of optically transparent, mechanically robust and flexible aerogels has been a longstanding challenge, which limits their practical applications in energy-saving devices, such as thermally insulating films for enhancing energy efficiency of windows. The poor transparency precluded even hypothetical consideration of the possibility of birefringent aerogels. We develop birefringent and optically isotropic aerogels that combine properties of thermal super-insulation, mechanical robustness and flexibility, and transparency to visible-spectrum light. This unusual combination of physical properties is achieved by combining liquid crystalline self-organization of cellulose nanofibers with polysiloxane cross-linking and control of the nanoscale porosity to form hybrid organic-inorganic mesostructured aerogels. Potential applications of these inexpensive materials range from single pane window retrofitting to smart fabrics.

  6. MCSA Windows Server 2012 R2 installation and configuration study guide exam 70-410

    CERN Document Server

    Panek, William

    2015-01-01

    Master Windows Server installation and configuration withhands-on practice and interactive study aids for the MCSA: WindowsServer 2012 R2 exam 70-410 MCSA: Windows Server 2012 R2 Installation and ConfigurationStudy Guide: Exam 70-410 provides complete preparationfor exam 70-410: Installing and Configuring Windows Server 2012 R2.With comprehensive coverage of all exam topics and plenty ofhands-on practice, this self-paced guide is the ideal resource forthose preparing for the MCSA on Windows Server 2012 R2. Real-worldscenarios demonstrate how the lessons are applied in everydaysettings. Reader

  7. Determining Window Placement and Configuration for the Small Pressurized Rover (SPR)

    Science.gov (United States)

    Thompson, Shelby; Litaker, Harry; Howard, Robert

    2009-01-01

    This slide presentation reviews the process of the evaluation of window placement and configuration for the cockpit of the Lunar Electric Rover (LER). The purpose of the evaluation was to obtain human-in-the-loop data on window placement and configuration for the cockpit of the LER.

  8. Windows Calorimeter Control (WinCal) program computer software configuration management plan

    International Nuclear Information System (INIS)

    1997-01-01

    This document describes the system configuration management activities performed in support of the Windows Calorimeter Control (WinCal) system, in accordance with Site procedures based on Institute of Electrical and Electronic Engineers (IEEE) Standard 828-1990, Standard for Software Configuration Management Plans (IEEE 1990) and IEEE Standard 1042-1987, Guide to Software Configuration Management (IEEE 1987)

  9. Beam Fields in an Integrated Cavity, Coupler and Window Configuration

    Energy Technology Data Exchange (ETDEWEB)

    Weathersby, Stephen; Novokhatski, Alexander; /SLAC

    2010-02-10

    In a multi-bunch high current storage ring, beam generated fields couple strongly into the RF cavity coupler structure when beam arrival times are in resonance with cavity fields. In this study the integrated effect of beam fields over several thousand RF periods is simulated for the complete cavity, coupler, window and waveguide system of the PEP-II B-factory storage ring collider. We show that the beam generated fields at frequencies corresponding to several bunch spacings for this case gives rise to high field strength near the ceramic window which could limit the performance of future high current storage rings such as PEP-X or Super B-factories.

  10. Ocean Engineering Studies. Volume 5. Acrylic Windows. Spherical Shell Configurations

    Science.gov (United States)

    1991-01-01

    with polishing of all surfaces and annealing at 1750F for 6 hours. Flanges for the windows were fabricated (figure 12) from st- el with a minimum yield...increase in radial apex displacement. The radial apex displacement becomes almost a step function just prior to plastico -elastic instability failure of...20,000 0 / 0 / 0.10 - ,, ,,/ ,0~/ ,oo El , ,--E implosion 2,000 4 ,000 5,000 8,000 PRESSURE (psi) Figure 15. -Iu.,ured Strain aid Displacement at the

  11. Investigation of Different Configurations of a Ventilated Window to Optimize Both Energy Efficiency and Thermal Comfort

    DEFF Research Database (Denmark)

    Liu, Mingzhe; Heiselberg, Per; Larsen, Olena Kalyanova

    2017-01-01

    ) for the calculation of the thermal and solar properties of commercial and innovative window systems. Additionally, comfort performance is evaluated by inlet air temperature and internal surface temperature of the windows calculated by WIS software. The results of the study show the energy and comfort performance...... the energy consumption or optimizing the thermal comfort. The provided optimal window typologies can be used in residential and commercial buildings for both new constructions and renovations.......The study in this article investigates 15 ventilated window typologies with different pane configurations and glazing types in climates of four European countries (United Kingdom, Denmark, France and Germany) in order to identify the optimum typology with regard to their energy balance and impact...

  12. MCSA Windows Server 2012 R2 configuring advanced services study guide exam 70-412

    CERN Document Server

    Panek, William

    2015-01-01

    The bestselling MCSA study guide, with expert instruction andhands-on practice MCSA Windows Server 2012 R2 Configuring Advanced ServicesStudy Guide provides focused preparation for exam 70-412 and isfully updated to align with the latest Windows Server 2012 R2objectives. This comprehensive guide covers 100 percent of all examobjective domains, and includes hundreds of practice questions andanswers. You get access to video demonstrations, electronicflashcards, and practice exams, and hands-on exercises based onreal-world scenarios allow you to apply your skills to everydaytasks. Organized by o

  13. Techniques and Results for Determining Window Placement and Configuration for the Small Pressurized Rover (SPR)

    Science.gov (United States)

    Thompson, Shelby; Litaker, Harry; Howard, Robert

    2009-01-01

    A natural component to driving any type of vehicle, be it Earth-based or space-based, is visibility. In its simplest form visibility is a measure of the distance at which an object can be seen. With the National Aeronautics and Space Administration s (NASA) Space Shuttle and the International Space Station (ISS), there are human factors design guidelines for windows. However, for planetary exploration related vehicles, especially land-based vehicles, relatively little has been written on the importance of windows. The goal of the current study was to devise a proper methodology and to obtain preliminary human-in-the-loop data on window placement and location for the small pressurized rover (SPR). Nine participants evaluated multiple areas along the vehicle s front "nose", while actively maneuvering through several lunar driving simulations. Subjective data was collected on seven different aspects measuring areas of necessity, frequency of views, and placement/configuration of windows using questionnaires and composite drawings. Results indicated a desire for a large horizontal field-of-view window spanning the front of the vehicle for most driving situations with slightly reduced window areas for the lower front, lower corners, and side views.

  14. An enhanced HPIV configuration for flow measurement through thick distorting windows

    Science.gov (United States)

    Alcock, R. D.; Garner, C. P.; Halliwell, N. A.; Coupland, J. M.

    2004-04-01

    This paper reports on a new holographic particle image velocimetry configuration and analysis procedure that can be used to measure particle displacement through thick distorting windows. The technique builds upon the scanning fibre probe based object conjugate reconstruction geometry; however it avoids the requirement of using a holographic optical element to correct for window distortion of the beams. Removal of the distortion is instead accomplished by using a ray trace mapping between the wave vectors scattered by the particles at the time of each exposure and those measured by the interrogation system. The technique is ideally suited to the study of flow structure within the combustion chamber of a diesel engine, and preliminary experimental results that attempt to assess the accuracy of the technique in this situation are presented.

  15. MCTS self-paced training kit (exam 70-680) configuring Windows 7

    CERN Document Server

    McLean, Ian

    2010-01-01

    NOTE: The most recent printings of this title incorporate corrections to errors found in the earlier printings. This Self-Paced Training Kit is designed to help maximize your performance on 70-680, the required exam for the Microsoft® Certified Technology Specialist (MCTS): Windows 7, Configuration certification.This 2-in-1 kit includes the official Microsoft study guide, plus practice tests on CD to help you assess your skills. It comes packed with the tools and features exam candidates want most-including in-depth, self-paced training based on final exam content; rigorous, objective-by-obj

  16. Windows Calorimeter Control (WinCal) system configuration control board (SCCB) operating procedure

    International Nuclear Information System (INIS)

    Westsik, G.A.

    1997-01-01

    This document describes the operating procedure for the System Configuration Control Board (SCCB) performed in support of the Windows Calorimeter Control (WinCal) system. This board will consist of representatives from Babcock and Wilcox Hanford Company Babcock and Wilcox Protec, Inc.; and Lockheed Martin Services, Inc. In accordance with agreements for the joint use of the Babcock and Wilcox Hanford Company calorimeters located in the Hanford Site Plutonium Finishing Plant (PFP) Nondestructive Assay Laboratory, concurrence regarding changes to the WinCal system will be obtained from the International Atomic Energy Agency (IAEA). Further, changes to the WinCal software will be communicated to Los Alamos National Laboratory

  17. A novel configurable VLSI architecture design of window-based image processing method

    Science.gov (United States)

    Zhao, Hui; Sang, Hongshi; Shen, Xubang

    2018-03-01

    Most window-based image processing architecture can only achieve a certain kind of specific algorithms, such as 2D convolution, and therefore lack the flexibility and breadth of application. In addition, improper handling of the image boundary can cause loss of accuracy, or consume more logic resources. For the above problems, this paper proposes a new VLSI architecture of window-based image processing operations, which is configurable and based on consideration of the image boundary. An efficient technique is explored to manage the image borders by overlapping and flushing phases at the end of row and the end of frame, which does not produce new delay and reduce the overhead in real-time applications. Maximize the reuse of the on-chip memory data, in order to reduce the hardware complexity and external bandwidth requirements. To perform different scalar function and reduction function operations in pipeline, this can support a variety of applications of window-based image processing. Compared with the performance of other reported structures, the performance of the new structure has some similarities to some of the structures, but also superior to some other structures. Especially when compared with a systolic array processor CWP, this structure at the same frequency of approximately 12.9% of the speed increases. The proposed parallel VLSI architecture was implemented with SIMC 0.18-μm CMOS technology, and the maximum clock frequency, power consumption, and area are 125Mhz, 57mW, 104.8K Gates, respectively, furthermore the processing time is independent of the different window-based algorithms mapped to the structure

  18. Windows

    DEFF Research Database (Denmark)

    Heiselberg, Per; Svidt, Kjeld; Nielsen, Peter V.

    In natural ventilation systems fresh air is often provided through opening of windows. However, the knowledge of the performance of windows is rather limited. Computation of natural ventilation air flow through windows is most commonly made using discharge coefficients, that are regarded as being...... constant. The reported results show that the discharge coefficient for a window opening cannot be regarded as a constant and that it varies considerably with the size of the opening area, the window type and the temperature difference. Therefore, the use of a constant value can lead to serious errors...

  19. Investigation of Retrofit Solutions of Window-Wall Assembly Based on FMEA, Energy Performance and Indoor Environment

    DEFF Research Database (Denmark)

    Morelli, Martin; Lauritsen, Diana; Svendsen, Svend

    2011-01-01

    to moisture from the inside. The box window has the lowest temperatures on the cavity surface and is therefore more vulnerable toward condensation. The basis of the rational optimisation approach is the total economy considering the initial, operational and maintenance costs over the lifetime of the building...

  20. A virtual control panel configuration tool for the X-Window system

    International Nuclear Information System (INIS)

    Hill, J.O.; Dalesio, L.R.; Kerstiens, D.M.

    1992-01-01

    Computer Graphics Workstations are becoming increasingly popular for use as virtual process control and read back panels. The workstation's CRT, keyboard, and pointing device are used in concert to produce a display that is in essence a control panel, even if actual switches and gauges are not present. The code behind these displays is most often specific to one display and not reusable for any other display. Recently, programs have been written allowing many of these virtual control panel displays to be configured without writing additional code. This approach allows the initial programming effort to be reapplied to many different display instances with minimal effort. These programs often incorporate many of the features of a graphics editor, allowing a pictorial model of the process under control to be incorporated into the control panel. We have just finished writing a second generation software system of this type for use with the X-window system and the Experimental Physics and Industrial Control System (EPICS). This paper describes the primary features of our software, the framework of our design, and our observations after initial installation. (author)

  1. MCTS Microsoft Windows 7 Configuration Study Guide Exam 70-680

    CERN Document Server

    Panek, William

    2011-01-01

    A fully updated study guide for MCTS exam 70-680 Demand for experienced, qualified Windows 7 administrators remains high. IT professionals seeking certification in Windows 7 administration will find everything they need to learn to pass the MCTS exam (70-680) in this complete Sybex Study Guide. Updated to cover the most recent version of the exam, this comprehensive guide examines all the exam objectives, using real-world scenarios, hands-on exercises, and challenging review questions.Certification in Windows 7 administration is highly prized by IT professionals and employers; this comprehensi

  2. Retrofit Best Practices Guide

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, T.K.

    2004-01-13

    Few people add siding or change their windows just to reduce their energy bills. But whatever your reasons for retrofitting your home, this will be an important opportunity to improve your home's energy efficiency. Not only will this reduce your utility bills, it will also improve your comfort level and improve our environment. Retrofitting your house is a big deal, and you shouldn't underestimate the effort that will be required to plan the job properly. The energy conservation rewards can be great, but there are also pitfalls that you'll want to avoid. That's what this Best Practices Guide is all about. We can't cover all the issues in these few pages, but we'll tell you some things you need to know if you're changing your siding or windows, and tell you where to learn more about other changes you may want to make to your house. What exactly is a ''best practice''? To put this guide together, we've tested products, talked to contractors and manufacturers, and reviewed the results from a large number of house retrofits. Of course, ''best'' will vary according to the situation. That's why you must start with a careful examination of your house and its existing condition.

  3. The influence of the thermo-phono-insulating glazing structure configuration of some PVC profile windows on the airborne sound insulation – case study

    Directory of Open Access Journals (Sweden)

    Marta Cristina ZAHARIA

    2012-12-01

    Full Text Available After conducting laboratory acoustic measurements of airborne sound insulation for several windows with the same type of PVC profiles, equipped with different types of phono- and thermal - insulating glazings, the influence of the window’s glazed part (glass structure configuration on airborne sound insulation was analyzed. The configuration of the structure’s glazed part requires its composition of glass sheets with different thicknesses or intermediate layers of air with different thicknesses. This configuration has an important influence on the acoustic response of windows, namely on the index of air noise sound insulation, Rw, and on the behavior of the entire measurement frequency range.

  4. Sunnyvale Marine Climate Deep Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    German, A.; Siddiqui, A.; Dakin, B.

    2014-11-01

    The Alliance for Residential Building Innovation (ARBI) and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House (PH) and Building America (BA) program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, upgrading the heating and cooling system, and installing.

  5. Sunnyvale Marine Climate Deep Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Siddiqui, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2014-11-01

    The Alliance for Residential Building Innovation (ARBI) and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House (PH) and Building America program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, upgrading the heating and cooling system, and installing mechanical ventilation.

  6. Carbon fiber reinforced polymer (CFRP inserted in different configurations of the tensile zone retrofitting with microconcrete containing steel fibers to the strengthening of beams

    Directory of Open Access Journals (Sweden)

    Vladimir José Ferrari

    2016-08-01

    Full Text Available It is researched, in this study, the strengthening technique known as Near Surface Mounted (NSM, which consists of the insertion of laminates of Carbon Fiber Reinforced Polymer (CFRP into notches in the covering concrete structures. In the strengthening in beams, the tensile zone is found damaged for several reasons (cracking and corrosion, for instance, which demands, in the practice of engineering, its preliminary retrofitting. It should be considered that the good performance of the material used in this retrofitting is fundamental for a higher efficiency of the strengthening. Therefore, it is proposed a methodology that consists of the reconstitution of the tensile zone of the beams with a cement-based composite of high performance (CCAD, which acts as a substrate for the application of CFRP and as an element for the transfer of efforts to the part strengthened. The retrofitting of this tensile zone was performed only in the shear span, as well as throughout of the zone with a view to evaluating the influence of this aspect on the performance of the beams. The CCAD, produced from Portland cement, steel fibers and microfibers, was evaluated using the Rilem (2002, showed to be able to delay the cracking. Tests performed in the beams with the tensile zone retrofitting by CCAD and strengthening using the technique NSM showed the efficiency of the proposed methodology.

  7. Retrofitting Systems

    DEFF Research Database (Denmark)

    Rose, Jørgen

    1997-01-01

    This report gives an overview of the different retrofitting possibilities that are available today. The report looks at both external and internal systems for external wall constructions, roof constructions, floor constructions and foundations. All systems are described in detail in respect to use...

  8. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, K. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Parker, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Martin, E. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Chasar, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Amos, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-02-03

    The BAPIRC team and Florida Power and Light (FPL) electric utility pursued a pilot phased energy-efficiency retrofit program in Florida by creating detailed data on the energy and economic performance of two levels of retrofit - simple and deep. For this Phased Deep Retrofit (PDR) project, a total of 56 homes spread across the utility partner's territory in east central Florida, southeast Florida, and southwest Florida were instrumented between August 2012 and January 2013, and received simple pass-through retrofit measures during the period of March 2013 - June 2013. Ten of these homes received a deeper package of retrofits during August 2013 - December 2013. A full account of Phase I of this project, including detailed home details and characterization, is found in Parker et al, 2015 (currently in draft). Phase II of this project, which is the focus of this report, applied the following additional retrofit measures to select homes that received a shallow retrofit in Phase I: a) Supplemental mini-split heat pump (MSHP) (6 homes); b) Ducted and space coupled Heat Pump Water Heater (8 homes); c) Exterior insulation finish system (EIFS) (1 homes); d) Window retrofit (3 homes); e) Smart thermostat (21 homes: 19 NESTs; 2 Lyrics); f) Heat pump clothes dryer (8 homes); g) Variable speed pool pump (5 homes).

  9. Evaluation of Crawlspace Retrofits in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Somerville, MA (United States)

    2014-09-01

    In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community unvented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring. The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this unvented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods.

  10. Evaluation of Crawlspace Retrofits in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community unvented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring. The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this unvented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods. While the unvented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

  11. Chamberlain Heights Redevelopment: A Large Scale, Cold Climate Study of Affordable Housing Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Donnelly, K. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Mahle, M. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2012-03-01

    The City of Meriden Housing Authority (MHA) collaborated with affordable housing developer Jonathon Rose Companies (JRC) to complete a gut renovation of 124 residential units in the Chamberlain Heights retrofit project. The affordable housing community is made up of 36 buildings in duplex and quad configurations located on 22 acres within two miles of downtown Meriden, CT. The final post-retrofit analysis showed 40-45% source energy savings over the existing pre-retrofit conditions.

  12. Cascade Apartments: Deep Energy Multifamily Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, A. [Washington State Univ. Energy Program, Olympia, WA (United States); Mattheis, L. [Washington State Univ. Energy Program, Olympia, WA (United States); Kunkle, R. [Washington State Univ. Energy Program, Olympia, WA (United States); Howard, L. [Washington State Univ. Energy Program, Olympia, WA (United States); Lubliner, M. [Washington State Univ. Energy Program, Olympia, WA (United States)

    2014-02-01

    In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions: 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit package after considering utility window incentives and KCHA capitol improvement funding.

  13. Cascade Apartments: Deep Energy Multifamily Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, A. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mattheis, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kunkle, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Howard, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lubliner, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions : 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit package after considering utility window incentives and KCHA capitol improvement funding.

  14. National Grid Deep Energy Retrofit Pilot

    Energy Technology Data Exchange (ETDEWEB)

    Neuhauser, K.

    2012-03-01

    Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high-performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Building enclosure retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance. Evaluation of strategies is structured around the critical control functions of water, airflow, vapor flow, and thermal control. The aim of the research project is to develop guidance that could serve as a foundation for wider adoption of high performance, 'deep' retrofit work. The project will identify risk factors endemic to advanced retrofit in the context of the general building type, configuration and vintage encountered in the National Grid DER Pilot. Results for the test homes are based on observation and performance testing of recently completed projects. Additional observation would be needed to fully gauge long-term energy performance, durability, and occupant comfort.

  15. Low-E Retrofit Demonstration and Educational Program

    Energy Technology Data Exchange (ETDEWEB)

    Culp, Thomas D [Birch Point Consulting LLC; Wiehagen, Joseph [Home Innovation Research Labs, Inc.; Drumheller, S Craig [Home Innovation Research Labs, Inc.; Siegel, John [Quanta Technologies Inc.; Stratmoen, Todd [Larson Manufacturing

    2013-11-16

    The objective of this project was to demonstrate the capability of low-emissivity (low-E) storm windows / panels and low-E retrofit glazing systems to significantly and cost effectively improve the energy efficiency of both existing residential and commercial buildings. The key outcomes are listed below: RESIDENTIAL CASE STUDIES: (a) A residential case study in two large multifamily apartment buildings in Philadelphia showed a substantial 18-22% reduction in heating energy use and a 9% reduction in cooling energy use by replacing old clear glass storm windows with modern low-E storm windows. Furthermore, the new low-E storm windows reduced the overall apartment air leakage by an average of 10%. (b) Air leakage testing on interior low-E panels installed in a New York City multifamily building over windows with and without AC units showed that the effective leakage area of the windows was reduced by 77-95%. (c) To study the use of low-E storm windows in a warmer mixed climate with a balance of both heating and cooling, 10 older homes near Atlanta with single pane windows were tested with three types of exterior storm windows: clear glass, low-E glass with high solar heat gain, and low-E glass with lower solar heat gain. The storm windows significantly reduced the overall home air leakage by an average of 17%, or 3.7 ACH50. Considerably high variability in the data made it difficult to draw strong conclusions about the overall energy usage, but for heating periods, the low-E storm windows showed approximately 15% heating energy savings, whereas clear storm windows were neutral in performance. For cooling periods, the low-E storm windows showed a wide range of performance from 2% to over 30% cooling energy savings. Overall, the study showed the potential for significantly more energy savings from using low-E glass versus no storm window or clear glass storm windows in warmer mixed climates, but it is difficult to conclusively say whether one type of low-E performed

  16. Retrofit of a Multifamily Mass Masonry Building in New England

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Kerrigan, P.; Wytrykowska, H.; Van Straaten, R.

    2013-08-01

    Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

  17. Commercial Building Energy Saver: An energy retrofit analysis toolkit

    International Nuclear Information System (INIS)

    Hong, Tianzhen; Piette, Mary Ann; Chen, Yixing; Lee, Sang Hoon; Taylor-Lange, Sarah C.; Zhang, Rongpeng; Sun, Kaiyu; Price, Phillip

    2015-01-01

    Highlights: • Commercial Building Energy Saver is a powerful toolkit for energy retrofit analysis. • CBES provides benchmarking, load shape analysis, and model-based retrofit assessment. • CBES covers 7 building types, 6 vintages, 16 climates, and 100 energy measures. • CBES includes a web app, API, and a database of energy efficiency performance. • CBES API can be extended and integrated with third party energy software tools. - Abstract: Small commercial buildings in the United States consume 47% of the total primary energy of the buildings sector. Retrofitting small and medium commercial buildings poses a huge challenge for owners because they usually lack the expertise and resources to identify and evaluate cost-effective energy retrofit strategies. This paper presents the Commercial Building Energy Saver (CBES), an energy retrofit analysis toolkit, which calculates the energy use of a building, identifies and evaluates retrofit measures in terms of energy savings, energy cost savings and payback. The CBES Toolkit includes a web app (APP) for end users and the CBES Application Programming Interface (API) for integrating CBES with other energy software tools. The toolkit provides a rich set of features including: (1) Energy Benchmarking providing an Energy Star score, (2) Load Shape Analysis to identify potential building operation improvements, (3) Preliminary Retrofit Analysis which uses a custom developed pre-simulated database and, (4) Detailed Retrofit Analysis which utilizes real-time EnergyPlus simulations. CBES includes 100 configurable energy conservation measures (ECMs) that encompass IAQ, technical performance and cost data, for assessing 7 different prototype buildings in 16 climate zones in California and 6 vintages. A case study of a small office building demonstrates the use of the toolkit for retrofit analysis. The development of CBES provides a new contribution to the field by providing a straightforward and uncomplicated decision

  18. Multifamily Ventilation Retrofit Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Lstiburek, J.; Bergey, D.

    2012-12-01

    In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

  19. Energy Performance of Verandas in the Building Retrofit Process

    Directory of Open Access Journals (Sweden)

    Rossano Albatici

    2016-05-01

    Full Text Available Passive solar elements for both direct and indirect gains, are systems used to maintain a comfortable living environment while saving energy, especially in the building energy retrofit and adaptation process. Sunspaces, thermal mass and glazing area and orientation have been often used in the past to guarantee adequate indoor conditions when mechanical devices were not available. After a period of neglect, nowadays they are again considered as appropriate systems to help face environmental issues in the building sector, and both international and national legislation takes into consideration the possibility of including them in the building planning tools, also providing economic incentives. Their proper design needs dynamic simulation, often difficult to perform and time consuming. Moreover, results generally suffer from several uncertainties, so quasi steady-state procedures are often used in everyday practice with good results, but some corrections are still needed. In this paper, a comparative analysis of different solutions for the construction of verandas in an existing building is presented, following the procedure provided by the slightly modified and improved Standard EN ISO 13790:2008. Advantages and disadvantages of different configurations considering thermal insulation, windows typology and mechanical ventilation systems are discussed and a general intervention strategy is proposed. The aim is to highlight the possibility of using sunspaces in order to increase the efficiency of the existing building stock, considering ease of construction and economic viability.

  20. Performance of a Hot-Dry Climate Whole-House Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Weitzel, E.; German, A.; Porse, E.

    2014-06-01

    The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

  1. Performance of a Hot-Dry Climate Whole-House Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Weitzel, E. [Alliance for Residential Building Innovation, Davis, CA (United States); German, A. [Alliance for Residential Building Innovation, Davis, CA (United States); Porse, E. [Alliance for Residential Building Innovation, Davis, CA (United States)

    2014-06-01

    The Stockton house retrofit is a two-story Tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

  2. Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, K.; Martin, E.

    2013-02-01

    This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

  3. Short-Term Test Results. Transitional Housing Energy Efficiency Retrofit in the Hot Humid Climate

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, K. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Martin, Eric [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States)

    2013-02-01

    This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30%-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

  4. Sunlight Responsive Thermochromic Window System

    Energy Technology Data Exchange (ETDEWEB)

    Millett, F,A; Byker,H, J

    2006-10-27

    Pleotint has embarked on a novel approach with our Sunlight Responsive Thermochromic, SRT™, windows. We are integrating dynamic sunlight control, high insulation values and low solar heat gain together in a high performance window. The Pleotint SRT window is dynamic because it reversibly changes light transmission based on thermochromics activated directly by the heating effect of sunlight. We can achieve a window package with low solar heat gain coefficient (SHGC), a low U value and high insulation. At the same time our windows provide good daylighting. Our innovative window design offers architects and building designers the opportunity to choose their desired energy performance, excellent sound reduction, external pane can be self-cleaning, or a resistance to wind load, blasts, bullets or hurricanes. SRT windows would provide energy savings that are estimated at up to 30% over traditional window systems. Glass fabricators will be able to use existing equipment to make the SRT window while adding value and flexibility to the basic design. Glazing installers will have the ability to fit the windows with traditional methods without wires, power supplies and controllers. SRT windows can be retrofit into existing buildings,

  5. Deep Energy Retrofit

    DEFF Research Database (Denmark)

    Zhivov, Alexander; Lohse, Rüdiger; Rose, Jørgen

    Deep Energy Retrofit – A Guide to Achieving Significant Energy User Reduction with Major Renovation Projects contains recommendations for characteristics of some of core technologies and measures that are based on studies conducted by national teams associated with the International Energy Agency...... Energy Conservation in Buildings and Communities Program (IEA-EBC) Annex 61 (Lohse et al. 2016, Case, et al. 2016, Rose et al. 2016, Yao, et al. 2016, Dake 2014, Stankevica et al. 2016, Kiatreungwattana 2014). Results of these studies provided a base for setting minimum requirements to the building...... envelope-related technologies to make Deep Energy Retrofit feasible and, in many situations, cost effective. Use of energy efficiency measures (EEMs) in addition to core technologies bundle and high-efficiency appliances will foster further energy use reduction. This Guide also provides best practice...

  6. Retrofitting models of inflation

    International Nuclear Information System (INIS)

    Kain, Ben

    2009-01-01

    I use the method of retrofitting, developed by Dine, Feng and Silverstein, to generate the scale of inflation dynamically, allowing it to be naturally small. This is a general procedure that may be performed on existing models of supersymmetric inflation. I illustrate this idea on two such models, one an example of F-term inflation and the other an example of D-term inflation.

  7. Evaluation of Retrofit Delivery Packages

    Energy Technology Data Exchange (ETDEWEB)

    M. Berman, P. Smith, and E. Porse

    2013-07-01

    Residential energy retrofit activities are a critical component of efforts to increase energy efficiency in the U.S. building stock; however, retrofits account for a small percentage of aggregate energy savings at relatively high per unit costs. This report by Building America research team, Alliance for Residential Building Innovation (ARBI), describes barriers to widespread retrofits and evaluates opportunities to improve delivery of home retrofit measures by identifying economies of scale in marketing, energy assessments, and bulk purchasing through pilot programs in portions of Sonoma, Los Angeles, and San Joaquin Counties, CA. These targeted communities show potential and have revealed key strategies for program design, as outlined in the report.

  8. Removable Window System for Space Vehicles

    Science.gov (United States)

    Grady, James P. (Inventor)

    2015-01-01

    A window system for a platform comprising a window pane, a retention frame, and a biasing system. The window pane may be configured to contact a sealing system. The retention frame may be configured to contact the sealing system and hold the window pane against the support frame. The biasing system may be configured to bias the retention frame toward the support frame while the support frame and the retention frame are in a configuration that holds the window pane. Removal of the biasing system may cause the retention frame and the window pane to be removable.

  9. Retrofitting Systems for External Walls

    DEFF Research Database (Denmark)

    Rose, Jørgen

    1997-01-01

    In this report, 9 different external and internal retrofitting systems are analyzed using numerical calculations. The analysis focuses on the thermal bridge effects in the different systems, and on this basis it is discussed whether internal or external retrofitting has the most advantages. The d....... The different systems are evaluated using 5 different types of existing walls....

  10. Carbon Absorber Retrofit Equipment (CARE)

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Eric [Neumann Systems Group, Incorporated, Colorado Springs, CO (United States)

    2015-12-23

    During Project DE-FE0007528, CARE (Carbon Absorber Retrofit Equipment), Neumann Systems Group (NSG) designed, installed and tested a 0.5MW NeuStream® carbon dioxide (CO2) capture system using the patented NeuStream® absorber equipment and concentrated (6 molal) piperazine (PZ) as the solvent at Colorado Springs Utilities’ (CSU’s) Martin Drake pulverized coal (PC) power plant. The 36 month project included design, build and test phases. The 0.5MW NeuStream® CO2 capture system was successfully tested on flue gas from both coal and natural gas combustion sources and was shown to meet project objectives. Ninety percent CO2 removal was achieved with greater than 95% CO2product purity. The absorbers tested support a 90% reduction in absorber volume compared to packed towers and with an absorber parasitic power of less than 1% when configured for operation with a 550MW coal plant. The preliminary techno-economic analysis (TEA) performed by the Energy and Environmental Research Center (EERC) predicted an over-the-fence cost of $25.73/tonne of CO2 captured from a sub-critical PC plant.

  11. Strengthening Building Retrofit Markets

    Energy Technology Data Exchange (ETDEWEB)

    Templeton, Mary [Michigan Saves; Jackson, Robert [Michigan Energy Office

    2014-04-15

    The Business Energy Financing (BEF) program offered commercial businesses in Michigan affordable financing options and other incentives designed to support energy efficiency improvements. We worked through partnerships with Michigan utilities, lenders, building contractors, trade associations, and other community organizations to offer competitive interest rates and flexible financing terms to support energy efficiency projects that otherwise would not have happened. The BEF program targeted the retail food market, including restaurants, grocery stores, convenience stores, and wholesale food vendors, with the goal of achieving energy efficiency retrofits for 2 percent of the target market. We offered low interest rates, flexible payments, easy applications and approval processes, and access to other incentives and rebates. Through these efforts, we sought to help customers strive for energy savings retrofits that would save 20 percent or more on their energy use. This program helped Michigan businesses reduce costs by financing energy efficient lighting, heating and cooling systems, insulation, refrigeration, equipment upgrades, and more. Businesses completed the upgrades with the help of our authorized contractors, and, through our lending partners, we provided affordable financing options.

  12. Measure Guideline. Wood Window Repair, Rehabilitation, and Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Baker, P. [Building Science Corporation, Somerville, MA (United States); Eng, P. [Building Science Corporation, Somerville, MA (United States)

    2012-12-01

    This measure guideline provides information and guidance on rehabilitating, retrofitting, and replacing existing window assemblies in residential construction. The intent is to provide information regarding means and methods to improve the energy and comfort performance of existing wood window assemblies in a way that takes into consideration component durability, in-service operation, and long term performance of the strategies.

  13. Retrofitting of NPP Computer systems

    International Nuclear Information System (INIS)

    Pettersen, G.

    1994-01-01

    Retrofitting of nuclear power plant control rooms is a continuing process for most utilities. This involves introducing and/or extending computer-based solutions for surveillance and control as well as improving the human-computer interface. The paper describes typical requirements when retrofitting NPP process computer systems, and focuses on the activities of Institute for energieteknikk, OECD Halden Reactor project with respect to such retrofitting, using examples from actual delivery projects. In particular, a project carried out for Forsmarksverket in Sweden comprising upgrade of the operator system in the control rooms of units 1 and 2 is described. As many of the problems of retrofitting NPP process computer systems are similar to such work in other kinds of process industries, an example from a non-nuclear application area is also given

  14. Retrofitting for fossil fuel flexibility

    International Nuclear Information System (INIS)

    Newell, J.; Trueblood, R.C.; Lukas, R.W.; Worster, C.M.; Marx, P.D.

    1991-01-01

    Described in this paper are two fossil plant retrofits recently completed by the Public Service Company of New Hampshire that demonstrate the type of planning and execution required for a successful project under the current regulatory and budget constraints. Merrimack Units 1 and 2 are 120 MW and 338 MW nominal cyclone-fired coal units in Bow, New Hampshire. The retrofits recently completed at these plants have resulted in improved particulate emissions compliance, and the fuel flexibility to allow switching to lower sulphur coals to meet current and future SO 2 emission limits. Included in this discussion are the features of each project including the unique precipitator procurement approach for the Unit 1 Retrofit, and methods used to accomplish both retrofits within existing scheduled maintenance outages through careful planning and scheduling, effective use of pre-outage construction, 3-D CADD modeling, modular construction and early procurement. Operating experience while firing various coals in the cyclone fired boilers is also discussed

  15. Advancing Residential Retrofits in Atlanta

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Roderick K [ORNL; Kim, Eyu-Jin [Southface Energy Institute; Roberts, Sydney [Southface Energy Institute; Stephenson, Robert [Southface Energy Institute

    2012-07-01

    This report will summarize the home energy improvements performed in the Atlanta, GA area. In total, nine homes were retrofitted with eight of the homes having predicted source energy savings of approximately 30% or greater based on simulated energy consumption.

  16. Windows 2012 Server network security securing your Windows network systems and infrastructure

    CERN Document Server

    Rountree, Derrick

    2013-01-01

    Windows 2012 Server Network Security provides the most in-depth guide to deploying and maintaining a secure Windows network. The book drills down into all the new features of Windows 2012 and provides practical, hands-on methods for securing your Windows systems networks, including: Secure remote access Network vulnerabilities and mitigations DHCP installations configuration MAC filtering DNS server security WINS installation configuration Securing wired and wireless connections Windows personal firewall

  17. Windows Azure

    CERN Document Server

    Johnson, Bruce; Chambers, James; Garber, Danny; Malik, Jamal; Fazio, Adam

    2013-01-01

    A collection of five must-have Azure titles, from some of the biggest names in the field Available individually, but at a discounted rate for the collection, this bundle of five e-books covers key developer and IT topics of Windows Azure, including ASP.NET, mobile services, web sites, data storage, and the hybrid cloud. A host of Microsoft employees and MPVs come together to cover the biggest challenges that professionals face when working with Windows Azure. The e-books included are as follows: Windows Azure and ASP.NET MVC MigrationWindows Azure Mobile ServicesWindows Azure Web SitesWindows

  18. The evaluation of retrofit measures in a tall residential building

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, M.M.; McLain, H.A.

    1995-07-01

    As part of a joint demonstration effort involving the US Department of Energy (DOE), the US Department of Housing and Urban Development (HUD), Boston Edison Company (BECo), and the Chelsea Housing Authority, Oak Ridge National Laboratory (ORNL) participated in the evaluation of energy and demand saving retrofits for a tall residential building located in Boston. The thirteen story all-electric building underwent window, lighting, and control renovations in December, 1992. annual energy consumption was reduced by 15% and peak demand fell by 17%. Hourly should building consumption data were available for the comparison of pre- and post- conditions and for calibration of a DOE-2.1D simulation model. The analysis found the window retrofit accounted for 90% of total energy savings and 95% of average demand savings, due to reductions in both conduction and infiltration. Benefits from lighting retrofits were low in cooling months and negligible in winter months due to the increase in the demand for electric resistance heating which was proportional to the reduction in lighting capacity. Finally, the simulation model verified that heating system controls had not been used as intended, and that the utility rate structure would not allow cost savings from the original control strategy. These results and other interesting lessons learned are presented.

  19. Deep Residential Retrofits in East Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Boudreaux, Philip R [ORNL; Hendrick, Timothy P [ORNL; Christian, Jeffrey E [ORNL; Jackson, Roderick K [ORNL

    2012-04-01

    Executive Summary Oak Ridge National Laboratory (ORNL) is furthering residential energy retrofit research in the mixed-humid climate of East Tennessee by selecting 10 homes and guiding the homeowners in the energy retrofit process. The homeowners pay for the retrofits, and ORNL advises which retrofits to complete and collects post-retrofit data. This effort is in accordance with the Department of Energy s Building America program research goal of demonstrating market-ready energy retrofit packages that reduce home energy use by 30 50%. Through this research, ORNL researchers hope to understand why homeowners decide to partake in energy retrofits, the payback of home energy retrofits, and which retrofit packages most economically reduce energy use. Homeowner interviews help the researchers understand the homeowners experience. Information gathered during the interviews will aid in extending market penetration of home energy retrofits by helping researchers and the retrofit industry understand what drives homeowners in making positive decisions regarding these retrofits. This report summarizes the selection process, the pre-retrofit condition, the recommended retrofits, the actual cost of the retrofits (when available), and an estimated energy savings of the retrofit package using EnergyGauge . Of the 10 households selected to participate in the study, only five completed the recommended retrofits, three completed at least one but no more than three of the recommended retrofits, and two households did not complete any of the recommended retrofits. In the case of the two homes that did none of the recommended work, the pre-retrofit condition of the homes and the recommended retrofits are reported. The five homes that completed the recommended retrofits are monitored for energy consumption of the whole house, appliances, space conditioning equipment, water heater, and most of the other circuits with miscellaneous electric loads (MELs) and lighting. Thermal comfort is

  20. Windows Home Server users guide

    CERN Document Server

    Edney, Andrew

    2008-01-01

    Windows Home Server brings the idea of centralized storage, backup and computer management out of the enterprise and into the home. Windows Home Server is built for people with multiple computers at home and helps to synchronize them, keep them updated, stream media between them, and back them up centrally. Built on a similar foundation as the Microsoft server operating products, it's essentially Small Business Server for the home.This book details how to install, configure, and use Windows Home Server and explains how to connect to and manage different clients such as Windows XP, Windows Vist

  1. Cascade Apartments - Deep Energy Multifamily Retrofit , Kent, Washington (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2014-02-01

    In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions : 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit package after considering utility window incentives and KCHA capitol improvement funding.

  2. Seismic retrofit benefit considering statewide transportation assessment.

    Science.gov (United States)

    2015-06-01

    The purpose of this study was to identify and demonstrate a methodology to prioritize bridges for : retrofit in the State of Oregon. Given the limited resources available, retrofitting all vulnerable bridges in the foreseeable : future would not be i...

  3. Green Retrofitting Skyscrapers: A Review

    Directory of Open Access Journals (Sweden)

    Kheir Al-Kodmany

    2014-09-01

    Full Text Available This paper investigates innovative trends, practices and goals of tall building retrofits while illustrating green design techniques and implementation strategies. The existing building stock is substantially large and represents one of the biggest opportunities to reduce energy waste and curb air pollution and global warming. In terms of tall buildings, many will benefit from retrofits. There are long lists of inefficient all-glass curtain walls, initially promoted by the modernist movement, that are due to retrofit. The all-glass curtain wall buildings rely on artificial ventilation, cooling and heating, and suffer from poor insulation, which collectively make them energy hogs. Recent practices indicate that green retrofit has helped older buildings to increase energy efficiency, optimize building performance, increase tenants’ satisfaction and boost economic return while reducing greenhouse gas emission. As such, renovating older buildings could be “greener” than destroying them and rebuilding new ones. While some demolition and replacement may remain a necessity to meet contemporary needs, there are significant opportunities to reduce carbon emission and improve existing buildings’ performance by retrofitting them rather than constructing new ones. Practical insight indicates that the confluence of economic and environmental goals is increasingly at the heart of sustainable planning and design.

  4. Strategy Guideline. Mitigation of Retrofit Risk Factors

    Energy Technology Data Exchange (ETDEWEB)

    Berman, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Smith, P. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Porse, E. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2012-12-01

    The Alliance for Residential Building Innovation (ARBI) Building America team is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

  5. Strategy Guideline: Mitigation of Retrofit Risk Factors

    Energy Technology Data Exchange (ETDEWEB)

    Berman, M.; Smith, P.; Porse, E.

    2012-12-01

    The Alliance for Residential Building Innovation (ARBI) is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

  6. Energy Retrofit for Aging K-12 Schools.

    Science.gov (United States)

    3D/International, Houston, TX.

    Successfully retrofitting aging K-12 schools using energy conservation measures (ECM) that can improve the physical plant and reduce energy consumption are explored. Topics explore how certain ECM measures can benefit educational facilities, why retrofitting begun sooner rather than later is important, how to finance the retrofit program, and the…

  7. Forensic Analysis of Windows Registry Against Intrusion

    OpenAIRE

    Haoyang Xie; Keyu Jiang; Xiaohong Yuan

    2012-01-01

    Windows Registry forensics is an important branch of computer and network forensics. Windows Registry is often considered as the heart of Windows Operating Systems because it contains allof the configuration setting of specific users, groups, hardware, software, and networks. Therefore, Windows Registry can be viewed as a gold mine of forensic evidences which could be used in courts. This paper introduces the basics of Windows Registry, describes its structure and its keys and subkeys thathav...

  8. EMCS Retrofit Analysis - Interim Report

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, R.C.; Salsbury, T.I.; Bell, G.C.; Huang, Y.J.; Sezgen, A.O.; Mazzucchi, R.; Romberger, J.

    1999-03-01

    This report presents the interim results of analyses carried out in the Phillip Burton Federal Building in San Francisco from 1996 to 1998. The building is the site of a major demonstration of the BACnet communication protocol. The energy management and control systems (EMCS) in the building were retrofitted with BACnet compatible controllers in order to integrate certain existing systems on one common network. In this respect, the project has been a success. Interoperability of control equipment from different manufacturers has been demonstrated in a real world environment. Besides demonstrating interoperability, the retrofits carried out in the building were also intended to enhance control strategies and capabilities, and to produce energy savings. This report presents analyses of the energy usage of HVAC systems in the building, control performance, and the reaction of the building operators. The report does not present an evaluation of the performance capabilities of the BACnet protocol. A monitoring system was installed in the building that parallels many of the EMCS sensors and data were archived over a three-year period. The authors defined pre-retrofit and post-retrofit periods and analyzed the corresponding data to establish the changes in building performance resulting from the retrofit activities. The authors also used whole-building energy simulation (DOE-2) as a tool for evaluating the effect of the retrofit changes. The results of the simulation were compared with the monitored data. Changes in operator behavior were assessed qualitatively with questionnaires. The report summarizes the findings of the analyses and makes several recommendations as to how to achieve better performance. They maintain that the full potential of the EMCS and associated systems is not being realized. The reasons for this are discussed along with possible ways of addressing this problem. They also describe a number of new technologies that could benefit systems of the type

  9. Retrofitting of existing housing stock

    DEFF Research Database (Denmark)

    Unterrainer, Walter

    2015-01-01

    The paper is a case study in retrofitting an urban quarter with social housing of the 1950´s and 1960´s - a model project in Amberg/Germany. It documents and discusses applied ´acupuncture´ and innovative strategies on very different scales as well as on different layers, in order to meet the goal...... of a sustainable retrofitting project in a holistic sense: This included cultural, social, environmental and economic sustainability. The first phase of the project is built and the process included a high level of user participation. The project is an example of integral design from competition level...

  10. Adaptive Liquid Crystal Windows

    Energy Technology Data Exchange (ETDEWEB)

    Taheri, Bahman; Bodnar, Volodymyr

    2011-12-31

    Energy consumption by private and commercial sectors in the U.S. has steadily grown over the last decade. The uncertainty in future availability of imported oil, on which the energy consumption relies strongly, resulted in a dramatic increase in the cost of energy. About 20% of this consumption are used to heat and cool houses and commercial buildings. To reduce dependence on the foreign oil and cut down emission of greenhouse gases, it is necessary to eliminate losses and reduce total energy consumption by buildings. To achieve this goal it is necessary to redefine the role of the conventional windows. At a minimum, windows should stop being a source for energy loss. Ideally, windows should become a source of energy, providing net gain to reduce energy used to heat and cool homes. It is possible to have a net energy gain from a window if its light transmission can be dynamically altered, ideally electronically without the need of operator assistance, providing optimal control of the solar gain that varies with season and climate in the U.S. In addition, the window must not require power from the building for operation. Resolution of this problem is a societal challenge and of national interest and will have a broad global impact. For this purpose, the year-round, allclimate window solution to provide an electronically variable solar heat gain coefficient (SHGC) with a wide dynamic range is needed. AlphaMicron, Inc. (AMI) developed and manufactured 1ft × 1ft prototype panels for the world’s first auto-adjusting Adaptive Liquid Crystal Windows (ALCWs) that can operate from sunlight without the need for external power source and demonstrate an electronically adjustable SHGC. This novel windows are based on AlphaMicron’s patented e-Tint® technology, a guesthost liquid crystal system implemented on flexible, optically clear plastic films. This technology is suitable both for OEM and aftermarket (retro-fitting) lamination to new and existing windows. Low level of

  11. Retrofit of a MultiFamily Mass Masonry Building in New England

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Somerville, MA (United States); Kerrigan, P. [Building Science Corporation, Somerville, MA (United States); Wytrykowska, H. [Building Science Corporation, Somerville, MA (United States); Van Straaten, R. [Building Science Corporation, Somerville, MA (United States)

    2013-08-01

    Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

  12. Retrofitting of existing housing stock

    DEFF Research Database (Denmark)

    Unterrainer, Walter

    2015-01-01

    The paper is a case study in retrofitting an urban quarter with social housing of the 1950´s and 1960´s - a model project in Amberg/Germany. It documents and discusses applied ´acupuncture´ and innovative strategies on very different scales as well as on different layers, in order to meet the goa...

  13. Windows 7 the definitive guide

    CERN Document Server

    Stanek, William R

    2010-01-01

    This book provides everything you need to manage and maintain Windows 7. You'll learn all of the features and enhancements in complete detail, along with specifics for configuring the operating system to put you in full control. Bestselling author and Windows expert William Stanek doesn't just show you the steps you need to follow, he also tells you how features work, why they work, and how you can customize them to meet your needs. Learn how to squeeze every bit of power out of Windows 7 to take full advantage of its features and programs. Set up, customize, and tune Windows 7-Optimize its

  14. CAVE WINDOW

    Science.gov (United States)

    Levenson, M.

    1960-10-25

    A cave window is described. It is constructed of thick glass panes arranged so that interior panes have smaller windowpane areas and exterior panes have larger areas. Exterior panes on the radiation exposure side are remotely replaceable when darkened excessively. Metal shutters minimize exposure time to extend window life.

  15. Window Stories

    DEFF Research Database (Denmark)

    Hauge, Bettina

    This research project has investigated 17 households in Germany (cities and rural areas). The main aim was to learn about the significance of the window to these people: What they think of their windows, how, when and why they use them in their everyday life, if they have a favorite window and why......, as well as the opposite. The report also includes a special focus on overheating and people’s strategies against this. Knowing about what people appreciate in a window and their actual practices and the reasons for their behaviour may be useful in many different ways, for instance to inform public...... of ethnographic tools that required their involvement, such as making a diary of their heating experiences during a random week in the summer of 2014, taking photos of windows and sending postcards with specific tasks....

  16. Advanced Catalytic Hydrogenation Retrofit Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Reinaldo M. Machado

    2002-08-15

    Industrial hydrogenation is often performed using a slurry catalyst in large stirred-tank reactors. These systems are inherently problematic in a number of areas, including industrial hygiene, process safety, environmental contamination, waste production, process operability and productivity. This program proposed the development of a practical replacement for the slurry catalysts using a novel fixed-bed monolith catalyst reactor, which could be retrofitted onto an existing stirred-tank reactor and would mitigate many of the minitations and problems associated with slurry catalysts. The full retrofit monolith system, consisting of a recirculation pump, gas/liquid ejector and monolith catalyst, is described as a monolith loop reactor or MLR. The MLR technology can reduce waste and increase raw material efficiency, which reduces the overall energy required to produce specialty and fine chemicals.

  17. Retrofit electrochromic glazing in a UK office

    Directory of Open Access Journals (Sweden)

    Ruth Kelly Waskett

    2014-12-01

    Full Text Available Electrochromic (EC glazing is now considered a viable alternative to fixed transmittance glazing. It has the potential to enable occupants to control daylight glare and solar heat gain without the use of blinds or external shading devices, giving users more access to daylight with all its inherent benefits. Furthermore, EC glazing can reduce energy consumption by decreasing cooling loads and electric lighting usage. Most research to date has studied the effects of EC glazing in scale models, computer simulations and full scale test rooms, and some of these studies have included human participants. However, there is a general lack of understanding regarding the performance and suitability of EC glazing in real-world working environments. A case study of the first UK retrofit application of EC glazing is being conducted in two adjacent offices in a university campus building. The offices are occupied by administration staff and have large southeastfacing windows. The existing double glazed units were replaced with commercially-available EC glazed units in 2012. Over a period of more than 18 months, the rooms were monitored intensively to record the effect of the EC glazing on both the physical room environment and the occupants themselves. A large amount of data from the monitoring programme is currently undergoing detailed analysis. Initial findings emerging from the installation and post-installation period are described in this paper.

  18. High performance solar control office windows

    Energy Technology Data Exchange (ETDEWEB)

    King, W.J.

    1977-12-01

    Investigations conducted over a 9 month period on the use of ion beam sputtering methods for the fabrication of solar control windows for energy conservation are described. Principal emphasis was placed on colored, reflecting, heat rejecting, office building windows for reducing air conditioning loads and to aid in the design of energy conserving buildings. The coating techniques were developed primarily for use with conventional absorbing plate glass such as PPG solarbronze, but were also demonstrated on plastic substrates for retrofit applications. Extensive material investigations were conducted to determine the optimum obtainable characteristics, with associated weathering studies as appropriate aimed at achieving a 20 year minimum life. Conservative estimates indicate that successful commercialization of the windows developed under this program would result in energy savings of 16,000,000 barrels of oil/year by 1990 if installation were only 10 percent of new commercial building stock. These estimates are relative to existing design for energy conserving windows. Installation in a greater percentage of new stock and for retrofit applications could lead to proportionately greater energy savings. All such installations are projected as cost effective as well as energy effective. A secondary program was carried out to modify the techniques to yield thermal control windows for residential applications. These windows were designed to provide a high heat retention capability without seriously affecting their transmission of incident solar radiation, thereby enhancing the greenhouse effect. This part of the program was successful in producing a window form which could be interchanged for standard residential window material in a cost and energy effective manner. The only variation from standard stock in appearance is a very light rose or neutral gray coloring.

  19. Potential Retrofit of Existing Sultan Ismail Parliament Building, Johor to Green Building

    Directory of Open Access Journals (Sweden)

    Yasin Mohd Norazam

    2017-01-01

    Full Text Available The concept of retrofitting an existing building towards green building was introduced to move towards greener development. This paper investigates the benefits of retrofitting an existing building to green building. The potential retrofit of the existing Sultan Ismail Parliament building was also determined and later the elements of the building to be retrofitted were proposed. The Sultan Ismail Parliament building is one of the newest development that serves as the Johor state administrative center under Iskandar Malaysia. Therefore, this paper focuses on whether the existing building has fulfilled all of the green building elements. A set of questionnaire was distributed to the targeted respondents who were the engineers, architects, technicians, staffs and those who were involved in the development of the Sultan Ismail Parliament building. A total of 60 respondents was involved. Based on the analyzed data, it shows that the existing building has fulfilled only one of the green building elements which is the Indoor Environmental Quality. The items that scored 3.5 and above mean index under this element include the daylight glare is not bothering, the ventilation in the building is adequate, inspections are done regularly, smoking regulation is implemented and the number of openings of windows and doors is sufficient. While it shows that other elements were only partially fulfilled. The criteria that achieved below 3.5 mean index values is considered to be the potential elements that could be used for future retrofitting initiative.

  20. Phased Retrofits in Existing Homes in Florida Phase II. Shallow Plus Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, K. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Parker, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Martin, E. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Chasar, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Amos, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-02-01

    The BAPIRC team and Florida Power and Light (FPL) electric utility pursued a pilot phased energy-efficiency retrofit program in Florida by creating detailed data on the energy and economic performance of two levels of retrofit - simple and deep. For this Phased Deep Retrofit (PDR) project, a total of 56 homes spread across the utility partner's territory in east central Florida, southeast Florida, and southwest Florida were instrumented between August 2012 and January 2013, and received simple pass-through retrofit measures during the period of March 2013 - June 2013. Ten of these homes received a deeper package of retrofits during August 2013 - December 2013.

  1. Quantifying the Financial Benefits of Multifamily Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Philbrick, D. [Elevate Energy, Chicago, IL (United States); Scheu, R. [Elevate Energy, Chicago, IL (United States); Brand, L. [Elevate Energy, Chicago, IL (United States)

    2016-01-01

    The U.S. Department of Energy’s Building America research team Partnership for Advanced Residential Retrofit analyzed building, energy, and financial program data as well as other public and private data to examine the relationship between energy-efficiency retrofits and financial performance on three levels: building, city, and community.

  2. Structuring lighting retrofit projects for success

    International Nuclear Information System (INIS)

    Fetters, J.L.

    1993-01-01

    Several trends are converging to create a substantial market for lighting retrofits in these uncertain economic times. Low interest rates are making investments in buildings more attractive than alternative financial investments such as CD's. With activity in the new construction market at an all time low, savvy contractors are turning to the retrofit market - restoring, renovating and upgrading existing buildings. Heightened environmental concerns are fueling lighting incentive programs from the electric utilities and the EPA. Improvements in lighting technology are arriving in the marketplace at an accelerated rate. Building occupants are demanding higher quality workplaces and managers are seeking higher levels of productivity. Replacing older lighting equipment can substantially improve lighting efficiency, decrease energy and maintenance costs and, at the same time, improve the workplace by increasing lighting quality Lighting retrofit projects have a demonstrated track record, reducing lighting costs on the order of 50%. This experience can be applied to help structure retrofit projects. But, in order to reap all the benefits available from a retrofit project, it must be structured for success. The retrofit option introduces a unique series of issues for building owners, managers and engineers. The best way to prevent these issues from undermining the success of retrofit projects is to anticipate and completely plan for them. Successful retrofit projects run smoothER and stay within budgetary constraints. Three important considerations will guide the successful project: (1) Start comprehensive planning early, (2) Investigate existing conditions, and (3) Be sensitive to owner/occupants needs keep building operational

  3. Prologis Rolls Out Warehouse Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-03-01

    Prologis partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce annual energy consumption by at least 30% versus pre-retrofit energy use as part of DOE’s Commercial Building Partnership (CBP) program.

  4. High Density Building Stock Retrofit through Solar Strategies and Hybrid Ventilation Systems

    OpenAIRE

    Barbolini, Fausto; Guardigli, Luca; Cappellacci, Paolo

    2014-01-01

    The very actual theme of building stock retrofit includes wide ranges of possible actions, especially in social housing. Multi-criteria assessments should be lead to evaluate the proper operational approach (considering social, structural, maintenance, thermal and economic parameters). The lower-impact actions typically involve improvements on the building skin, such as insulation and window re-placement, while the higher-impact solutions lead to demolition and re-building. Overall, building ...

  5. Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4

    Energy Technology Data Exchange (ETDEWEB)

    Moore, M.

    2013-08-01

    Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes - such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study's results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

  6. Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Mike [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2013-08-01

    Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes – such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study’s results will be used to identify cost-effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

  7. Proven Performance of Seven Cold Climate Deep Retrofit Homes

    Energy Technology Data Exchange (ETDEWEB)

    Osser, R.; Neuhauser, K.; Ueno, K.

    2012-06-01

    Seven test homes located in Massachusetts are examined within this report. The retrofit strategies of each home are presented along with a comparison of the pre- and post-retrofit airtightness achieved by the group. Pre- and post-retrofit utility bills were collected; energy models were used to estimate pre-retrofit energy use when bills were unavailable.

  8. Rugged Ceramic Window for RF Applications

    International Nuclear Information System (INIS)

    Neubauer, Michael; Johnson, Rolland P.; Rimmer, Robert; Elliot, Tom; Stirbet, Mircea

    2009-01-01

    High-current RF cavities that are needed for many accelerator applications are often limited by the power transmission capability of the pressure barriers (windows) that separate the cavity from the power source. Most efforts to improve RF window design have focused on alumina ceramic, the most popular historical choice, and have not taken advantage of new materials. Alternative window materials have been investigated using a novel Merit Factor comparison and likely candidates have been tested for the material properties which will enable construction in the self-matched window configuration. Window assemblies have also been modeled and fabricated using compressed window techniques which have proven to increase the power handling capability of waveguide windows. Candidate materials have been chosen to be used in fabricating a window for high power testing at Thomas Jefferson National Accelerator Facility.

  9. An Intelligent Window for Optimal Ventilation and Minimum Thermal Loss

    DEFF Research Database (Denmark)

    Mortensen, Lone Hedegaard; Rose, Jørgen; Liu, Mingzhe

    This report compares the simulation results of 12 window typologies for four countries on four selected days. The simulation results are used to select the window frame construction including glazing type and pane configuration.......This report compares the simulation results of 12 window typologies for four countries on four selected days. The simulation results are used to select the window frame construction including glazing type and pane configuration....

  10. Nordic campus retrofitting concepts - Scalable practices

    DEFF Research Database (Denmark)

    Eriksson, Robert; Nenonen, Suvi; Junghans, Antje

    2015-01-01

    were about the new ways of researching, collaborating and learning with the concepts of Living lab, Creative community for innovation and entrepreneurship and Network of learning hubs. The cases provided the first insights on retrofitting based on users’ changing needs and the requirements of more......Multidisciplinary collaboration and transformations in learning processes can be supported by activity-based campus retrofitting. The aim of this paper is to analyse the ongoing campus retrofitting processes at the three university campuses and to identify the elements of activity...

  11. Strategic Windows

    DEFF Research Database (Denmark)

    Risberg, Annette; King, David R.; Meglio, Olimpia

    We examine the importance of speed and timing in acquisitions with a framework that identifies management considerations for three interrelated acquisition phases (selection, deal closure and integration) from an acquiring firm’s perspective. Using a process perspective, we pinpoint items within...... acquisition phases that relate to speed. In particular, we present the idea of time-bounded strategic windows in acquisitions consistent with the notion of kairòs, where opportunities appear and must be pursued at the right time for success to occur....

  12. Window shopping

    OpenAIRE

    Oz Shy

    2013-01-01

    The terms "window shopping" and "showrooming" refer to the activity in which potential buyers visit a brick-and-mortar store to examine a product but end up either not buying it or buying the product from an online retailer. This paper analyzes potential buyers who differ in their preference for after-sale service that is not offered by online retailers. For some buyers, making a trip to the brick-and-mortar store is costly; however, going to the store to examine the product has the advantage...

  13. Retrofitting and the mu Problem

    Energy Technology Data Exchange (ETDEWEB)

    Green, Daniel; Weigand, Timo; /SLAC /Stanford U., Phys. Dept.

    2010-08-26

    One of the challenges of supersymmetry (SUSY) breaking and mediation is generating a {mu} term consistent with the requirements of electro-weak symmetry breaking. The most common approach to the problem is to generate the {mu} term through a SUSY breaking F-term. Often these models produce unacceptably large B{mu} terms as a result. We will present an alternate approach, where the {mu} term is generated directly by non-perturtative effects. The same non-perturbative effect will also retrofit the model of SUSY breaking in such a way that {mu} is at the same scale as masses of the Standard Model superpartners. Because the {mu} term is not directly generated by SUSY breaking effects, there is no associated B{mu} problem. These results are demonstrated in a toy model where a stringy instanton generates {mu}.

  14. Seismic retrofit guidelines for Utah highway bridges.

    Science.gov (United States)

    2009-05-01

    Much of Utahs population dwells in a seismically active region, and many of the bridges connecting transportation lifelines predate the rigorous seismic design standards that have been developed in the past 10-20 years. Seismic retrofitting method...

  15. Quantifying the Financial Benefits of Multifamily Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Philbrick, D. [The Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Scheu, R. [The Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Brand, L. [The Partnership for Advanced Residential Retrofit, Chicago, IL (United States)

    2016-01-29

    Increasing the adoption of energy efficient building practices will require the energy sector to increase their understanding of the way that retrofits affect multifamily financial performance as well as how those indicators are interpreted by the lending and appraisal industries. This project analyzed building, energy, and financial program data as well as other public and private data to examine the relationship between energy efficiency retrofits and financial performance on three levels: building, city, and community. The project goals were to increase the data and analysis in the growing body of multifamily financial benefits work as well provide a framework for other geographies to produce similar characterization. The goals are accomplished through three tasks. Task one: A pre- and post-retrofit analysis of thirteen Chicago multifamily buildings. Task two: A comparison of Chicago income and expenses to two national datasets. Task three: An in-depth look at multifamily market sales data and the subsequent impact of buildings that undergo retrofits.

  16. A multi-objective optimization model for energy-efficiency building envelope retrofitting plan with rooftop PV system installation and maintenance

    International Nuclear Information System (INIS)

    Fan, Yuling; Xia, Xiaohua

    2017-01-01

    Highlights: • A multi-objective optimization model for building envelope retrofit is presented. • Facility performance degradation and maintenance is built into the model. • A rooftop PV system is introduced to produce electricity. • Economic factors including net present value and payback period are considered. - Abstract: Retrofitting existing buildings with energy-efficient facilities is an effective method to improve their energy efficiency, especially for old buildings. A multi-objective optimization model for building envelope retrofitting is presented. Envelope components including windows, external walls and roofs are considered to be retrofitted. Installation of a rooftop solar panel system is also taken into consideration in this study. Rooftop solar panels are modeled with their degradation and a maintenance scheme is studied for sustainability of energy and its long-term effect on the retrofitting plan. The purpose is to make the best use of financial investment to maximize energy savings and economic benefits. In particular, net present value, the payback period and energy savings are taken as the main performance indicators of the retrofitting plan. The multi-objective optimization problem is formulated as a non-linear integer programming problem and solved by a weighted sum method. Results of applying the designed retrofitting plan to a 50-year-old building consisting of 66 apartments demonstrated the effectiveness of the proposed model.

  17. Parenthetical Windows

    DEFF Research Database (Denmark)

    Lemi, Esther; Triantafyllidis, Georgios

    2016-01-01

    artificial from natural stimuli and detects common and individual needs by measuring heart pulse and body temperature. The focal point here is light and how light affects human perception while at the same time the perception of sound and how gesture can provide the best possible cognition of actual needs...... light is a form that adapts natures’ properties and modifies the artificial environment as a stage direction, implying at the same time mood and modifying it in collaboration with sound. Having evaluated how this affects the body and human perception in this particular time that we experience nowadays......Parenthetical Window is a project that engages scientific research in human perception providing a platform for users to experience their own limits and needs in their individual circadian rhythm. The presentation focuses on a case study in a community of dancers where the individual needs in light...

  18. Post-Retrofit Residential Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Lancaster, Ross; lutzenhiser, Loren; Moezzi, Mithra; Widder, Sarah H.; Chandra, Subrato; Baechler, Michael C.

    2012-04-30

    This study examined a range of factors influencing energy consumption in households that had participated in residential energy-efficiency upgrades. The study was funded by a grant from the U.S. Department of Energy’s Pacific Northwest National Laboratory and was conducted by faculty and staff of Portland State University Center for Urban Studies and Department of Economics. This work was made possible through the assistance and support of the Energy Trust of Oregon (ETO), whose residential energy-efficiency programs provided the population from which the sample cases were drawn. All households in the study had participated in the ETO Home Performance with Energy Star (HPwES) program. A number of these had concurrently pursued measures through other ETO programs. Post-retrofit energy outcomes are rarely investigated on a house-by-house basis. Rather, aggregate changes are ordinarily the focus of program impact evaluations, with deviation from aggregate expectations chalked up to measurement error, the vagaries of weather and idiosyncrasies of occupants. However, understanding how homes perform post-retrofit on an individual basis can give important insights to increase energy savings at the participant and the programmatic level. Taking a more disaggregated approach, this study analyzed energy consumption data from before and after the retrofit activity and made comparisons with engineering estimates for the upgrades, to identify households that performed differently from what may have been expected based on the estimates. A statistical analysis using hierarchal linear models, which accounted for weather variations, was performed looking separately at gas and electrical use during the periods before and after upgrades took place. A more straightforward comparison of billing data for 12-month periods before and after the intervention was also performed, yielding the majority of the cases examined. The later approach allowed total energy use and costs to be

  19. Windows Vista Administrator's Pocket Guide

    CERN Document Server

    Stanek, William R

    2007-01-01

    Portable and precise, this pocket-sized guide delivers immediate answers for the day-to-day administration of Windows Vista. Zero in on core support and maintenance tasks using quick-reference tables, instructions, and lists. You'll get the precise information you need to solve problems and get the job done-whether you're at your desk or in the field! Get fast facts to: Install and configure Windows Vista-and optimize the user workspaceMaintain operating system components, hardware devices, and driversCreate user and group accounts-and control rights and permissionsAdminister group policy se

  20. Experimental and numerical results from hybrid retrofitted photovoltaic panels

    International Nuclear Information System (INIS)

    Rossi, Cecilia; Tagliafico, Luca A.; Scarpa, Federico; Bianco, Vincenzo

    2013-01-01

    Highlights: • The experimental study focuses on the feasibility of hybrid PV/T panels retrofitting. • The critical role of a thin layer of air between PV panel and back plate is evidenced. • The benefit of the addition of a conductive paste layer is analyzed via FEM simulations. • The use of wood ribs to stick the back plate represents a cheap effective solution. - Abstract: The aim of present study is to investigate different methodologies to achieve a better contact between a photovoltaic panel and a thermal plate, in order to cool the PV panel by means of water in the perspective of coupling it with a heat pump. It is believed that this kind of system allows to obtain a higher energy efficiency. The analysis is developed both experimentally and numerically, testing different kinds of configurations in different operating conditions. Simulations are employed to analyze the effect of the variations of the contact resistance between the panel and the thermal plates, demonstrating that the use of a conductive paste increases the overall performance of the panel. Results show interesting possibilities in terms of retrofitting of existing photovoltaic panels by employing very simple solutions, such as to fix the thermal plate on the rear of the panel by means of wood ribs

  1. Performance analysis and pilot plant test results for the Komorany fluidized bed retrofit project

    Energy Technology Data Exchange (ETDEWEB)

    Snow, G.C. [POWER International, Inc., Coeur d`Alene, ID (United States)

    1995-12-01

    Detailed heat and mass balance calculations and emission performance projections are presented for an atmospheric fluidized bed boiler bottom retrofit at the 927 MWt (steam output) Komorany power station and district heating plant in the Czech Republic. Each of the ten existing boilers are traveling grate stoker units firing a local, low-rank brown coal. This fuel, considered to be representative of much of the coal deposits in Central Europe, is characterized by an average gross calorific value of 10.5 MJ/kg (4,530 Btu/lb), an average dry basis ash content of 47 %, and a maximum dry basis sulfur content of 1.8 % (3.4 % on a dry, ash free basis). The same fuel supply, together with limestone supplied from the region will be utilized in the retrofit fluidized bed boilers. The primary objectives of this retrofit program are, (1) reduce emissions to a level at or below the new Czech Clean Air Act, and (2) restore plant capacity to the original specification. As a result of the AFBC retrofit and plant upgrade, the particulate matter emissions will be reduced by over 98 percent, SO{sub 2} emissions will be reduced by 88 percent, and NO{sub x} emissions will be reduced by 38 percent compared to the present grate-fired configuration. The decrease in SO{sub 2} emissions resulting from the fluidized bed retrofit was initially predicted based on fuel sulfur content, including the distribution among organic, pyritic, and sulfate forms; the ash alkalinity; and the estimated limestone calcium utilization efficiency. The methodology and the results of this prediction were confirmed and extended by pilot scale combustion trials at a 1.0 MWt (fuel input), variable configuration test facility in France.

  2. Existing Whole-House Solutions Case Study: Cascade Apartments - Deep Energy Multifamily Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-02-01

    In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington, which resulted in annual energy cost savings of 22%, improved comfort and air quality for residents, and increased durability of the units. This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary Building America research questions: 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio of the retrofit package after considering utility window incentives and KCHA capital improvement funding.

  3. Building exterior retrofit and its impact on energy performance - a case study

    Energy Technology Data Exchange (ETDEWEB)

    Trovato, Nick [Read Jones Christoffersen Ltd (Canada)

    2011-07-01

    The building envelope plays a vital role in energy performance and the comfort of the building's occupants. The office building of Read Jones Christofferesen Ltd. (RJC) had excessive condensation problems with water and air leakages resulting in high-energy consumption. Hence, it required a building envelope retrofit. This paper presents a description of the existing building, improvements made to the building envelope and the mechanical system and the integration of the two systems and how this impacted the energy performance of the building. The owner had certain requirements for the retrofit, such as optimum climate control, wide window opening space, and maximum lighting. Exterior upgrades included, among others, stopping the air and water leakage, improved thermal resistance and reduced vapor diffusion. The renovation resulted in reduced energy consumption, a more comfortable working environment, better mechanical system control, and around 65% in gas consumption and mechanical cost savings.

  4. Choosing the Right Fireplace or Fireplace Retrofit Device

    Science.gov (United States)

    This page is about choosing a fireplace or fireplace retrofit device, including information on hang tags and a list of fireplaces and retrofits that have qualified under the voluntary fireplace program

  5. National Grid Deep Energy Retrofit Pilot

    Energy Technology Data Exchange (ETDEWEB)

    Neuhauser, K. [Building Science Corporation (BSC), Somervgille, MA (United States)

    2012-03-01

    Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high-performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Building enclosure retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance.

  6. Retrofitting bus fleet for natural gas operation

    International Nuclear Information System (INIS)

    Stella, E.; Foresti, P.

    1992-01-01

    Buses, operating within a Florence (Italy) municipal transportation system, and equipped with Otto cycle engines, were selected for retrofitting taking into account the suitability of each vehicle's specific routing and service requirements. Cost benefit analyses indicated that it wouldn't be economically feasible to retrofit buses equipped with diesel engines. A computerized refuelling system was set up at the fleet's central service station which was hooked up to the natural gas utility's supply line. This paper tables the cost benefit analysis data comparing gasoline and methane operation and reflecting the cost savings which are expected to be accrued through this methanization program over a span of 14 years

  7. Advanced Energy Retrofit Guide Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guopeng; Liu, Bing; Wang, Weimin; Zhang, Jian; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

    2011-09-27

    The Advanced Energy Retrofit Guide for Office Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

  8. Advanced Energy Retrofit Guide Retail Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guopeng; Liu, Bing; Zhang, Jian; Wang, Weimin; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

    2011-09-19

    The Advanced Energy Retrofit Guide for Retail Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

  9. Diesel retrofit assessment for NYS DOT to retrofit its existing engine fleet.

    Science.gov (United States)

    2010-08-01

    The NYS DEC has required the use of retrofit technologies for various state agency, state public authority, and regional public authority heavy duty vehicles, as well as heavy duty vehicles used on behalf of such agencies and authorities. This report...

  10. Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Parker, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Sutherland, K. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Chasar, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Montemurno, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Amos, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Kono, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-02-01

    The U.S. Department of Energy (DOE) Building America program, in collaboration with Florida Power and Light (FPL), conducted a phased residential energy-efficiency retrofit program. This research sought to establish impacts on annual energy and peak energy reductions from the technologies applied at two levels of retrofit - shallow and deep, with savings levels approaching the Building America program goals of reducing whole-house energy use by 40%. Under the Phased Deep Retrofit (PDR) project, we have installed phased, energy-efficiency retrofits in a sample of 56 existing, all-electric homes. End-use savings and economic evaluation results from the phased measure packages and single measures are summarized in this report.

  11. Windows 7 A quick, hands-on introduction

    CERN Document Server

    Lee, Wei-Meng

    2009-01-01

    This compact book offers the quickest path for Windows users to get started with Microsoft's Windows 7 operating system. You get the essential information you need to upgrade or install the system and configure it to fit your activities, along with a tour of Windows 7's features and built-in applications. Microsoft has learned from the mistakes of Windows Vista, and Windows 7 shows it-this new OS is much faster and more stable. With Windows 7: Up and Running, you'll learn what's new and what's changed from XP and Vista, and get advice on ways to use this system for work, entertainment, inst

  12. Phased Retrofits in Existing Homes In Florida Phase I: Shallow and Deep Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Parker, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Sutherland, K. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Chasar, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Montemurno, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Amos, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Kono, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-02-04

    The U.S. Department of Energy (DOE) Building America program, in collaboration with Florida Power and Light (FPL), conducted a phased residential energy-efficiency retrofit program. This research sought to establish impacts on annual energy and peak energy reductions from the technologies applied at two levels of retrofit - shallow and deep, with savings levels approaching the Building America program goals of reducing whole-house energy use by 40%. Under the Phased Deep Retrofit (PDR) project, we have installed phased, energy-efficiency retrofits in a sample of 56 existing, all-electric homes. End-use savings and economic evaluation results from the phased measure packages and single measures are summarized in this report. Project results will be of interest to utility program designers, weatherization evaluators, and the housing remodel industry. Shallow retrofits were conducted in all homes from March to June 2013. The measures for this phase were chosen based on ease of installation, targeting lighting (CFLs and LED lamps), domestic hot water (wraps and showerheads), refrigeration (cleaning of coils), pool pump (reduction of operating hours), and the home entertainment center (smart plugs). Deep retrofits were conducted on a subset of ten PDR homes from May 2013 through March 2014. Measures included new air source heat pumps, duct repair, ceiling insulation, heat pump water heaters, variable speed pool pumps and learning thermostats. Major appliances such as refrigerators and dishwashers were replaced where they were old and inefficient.

  13. Greenbuilt Retrofit Test House Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Earle, L.; Booten, C.; Tabares-Velasco, P. C.; Barker, G.; Hancock, C. E.

    2014-06-01

    The Greenbuilt house, is an all-electric, 1980's era home in the eastern Sacramento suburb of Fair Oaks that was retrofit by Greenbuilt Construction as part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration (EERD) Program. The project was a joint effort between the design-build team at Greenbuilt Construction, led by Jim Bayless, SMUD and their project manager Mike Keesee, and the National Renewable Energy Laboratory (NREL). The goal of the Energy Efficient Remodel Demonstration program is to work with local builders to renovate homes with cost-effective energy efficient retrofit measures. The homes remodeled under the EERD program are intended to showcase energy efficient retrofit options for homeowners and other builders. The Greenbuilt house is one of five EERD projects that NREL has supported. NREL's main role in these projects is to provide energy analysis and to monitor the home's performance after the retrofit to verify that the energy consumption is in line with the modeling predictions. NREL also performed detailed monitoring on the more innovative equipment included in these remodels, such as an add-on heat pump water heater.

  14. Retrofitting the 5045 Klystron for Higher Efficiency

    International Nuclear Information System (INIS)

    Jensen, Aaron; Fazio, Michael; Haase, Andy; Jongewaard, Erik; Kemp, Mark; Neilson, Jeff

    2015-01-01

    The 5045 klystron has been in production and accelerating particles at SLAC National Accelerator Laboratory for over 25 years. Although the design has undergone some changes there are still significant opportunities for improvement in performance. Retrofitting the 5045 for higher efficiencies and a more mono-energetic spent beam profile is presented.

  15. Dowel bar retrofit performance in Wisconsin.

    Science.gov (United States)

    2010-05-01

    In 1999, WisDOT constructed test sections on I-39 to evaluate the dowel bar retrofit (DBR) rehabilitation technique for faulted concrete pavement slabs. Two years later, mortar deterioration and debonding were noted in the dowel slots. In response to...

  16. Retrofitting unreinforced masonry | Ngowi | Botswana Journal of ...

    African Journals Online (AJOL)

    This paper is expected to provide general guidelines to practicing Engineers to assist them in deciding the appropriate alternatives in strengthening unreinforced masonry structures. Key Words: Unreinforced masonry, structural strengthening, Fibre Reinforced Polymer, Earthquake, retrofitting, wind. Botswana Journal of ...

  17. Underwater Adhesives Retrofit Pipelines with Advanced Sensors

    Science.gov (United States)

    2015-01-01

    Houston-based Astro Technology Inc. used a partnership with Johnson Space Center to pioneer an advanced fiber-optic monitoring system for offshore oil pipelines. The company's underwater adhesives allow it to retrofit older deepwater systems in order to measure pressure, temperature, strain, and flow properties, giving energy companies crucial data in real time and significantly decreasing the risk of a catastrophe.

  18. DIESEL ENGINE RETROFIT TECHNOLOGY VERIFICATION (POSTER)

    Science.gov (United States)

    ETV is presenting a poster at the EPA's 2005 Science Forum from May 16-18, 2005 in Washington, DC. This poster will contain a summary of the performance results realized by the six verified diesel retrofit technologies, as well as potential impacts that could be realized if sigi...

  19. Sustainable Retrofitting of Nordic University Campuses

    DEFF Research Database (Denmark)

    Eriksson, Robert; Nenonen, Suvi; Nielsen, Susanne Balslev

    2014-01-01

    Purpose The purpose of this paper is to identify the state-of-art of Nordic campus development and identify how campus areas can be retrofitted by addition of new technologies, features, functions and services. The leading research question is: how to develop Nordic resilient campus management...

  20. Homeowner Best Practices Guide for Residential Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.

    2005-09-01

    This best practices guide for HV AC system retrofits is aimed at homeowners who want guidance on upgrading their heating, cooling and ventilation (HVAC) systems and integrating these upgrades with other changes to their home. It has been developed around the idea of having packages of changes to the building HV AC system and building envelope that are climate and house construction dependent. These packages include materials procedures and equipment, and are designed to remove some of the guesswork when selecting a builder, contractor, or installer. The packages are not meant to be taken as rigid requirements - instead they are systems engineered guidelines that form the basis for energy efficient retrofits. Similar approaches have been taken previously for new construction, where a systems engineering approach has been used to develop extremely energy-efficient homes that are comfortable safe and durable, and often cost less than standard construction. This approach is best epitomized by the Building America program, whose partners have built thousands of residences throughout the U.S. using these principles. The differences between retrofitting and new construction tend to limit the changes one can make to a building, so these packages rely on relatively simple and non-intrusive technologies and techniques. The retrofits also focus on changes to a building that will give many years of service to the occupants. Another key aspect of these best practices is that we need to know how a house is working so that we know what parts have the potential for improvement. To do this we have put together a set of simple tests that a homeowner can perform on their own together with checklists and questionnaires. The measured test results, observations and homeowner answers to questions are used to direct us towards the best retrofits applicable to each individual house. The retrofits will depend on the current condition of the building envelope and HV AC system, the local

  1. Best practices guide for residential HVAC Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.

    2003-08-11

    This best practices guide for residential HVAC system retrofits is aimed at contractors who want guidance on delivering energy efficient, cost effective and innovative products. It has been developed around the idea of having packages of changes to the building HVAC system and building envelope that are climate and house construction dependent. These packages include materials, procedures and equipment and are designed to remove some of the guesswork from a builder, contractor, installer or homeowner decisions about how best to carry out HVAC changes. The packages are not meant to be taken as rigid requirements--instead they are systems engineered guidelines that form the basis for energy efficient retrofits. Similar approaches have been taken previously for new construction to develop extremely energy efficient homes that are comfortable safe and durable, and often cost less than standard construction. This is best epitomized by the Building America program whose partners have built thousands of residences throughout the U.S. using these principles. The differences between retrofitting and new construction tend to limit the changes one can make to a building, so these packages rely on relatively simple and non-intrusive technologies and techniques. The retrofits also focus on changes to a building that will give many years of service to the occupants. Another key aspect of these best practices is that we need to know how a house is working so that we know what parts have the potential for improvement. To do this we have put together a set of diagnostic tools that combine physical measurements and checklists/questionnaires. The measured test results, observations and homeowner answers to questions are used to direct us towards the best retrofits applicable to each individual house. The retrofits will depend on the current condition of the building envelope and HVAC system, the local climate, the construction methods used for the house, and the presence of various

  2. Energy consumption and indoor climate in a residential building before and after comprehensive energy retrofitting

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Rose, Jørgen; Christen Mørck, Ove

    2016-01-01

    including new facades, new windows, additional insulation, mechanical ventilation with heat recovery and a photovoltaic installation on the roof. The measured energy consumption for heating and domestic hot water before and after renovation was 139.1 kWh/m2/year and 95.6 kWh/m2/year respectively...... before and after the retrofit. In three of the flats in Traneparken measurements of ventilation conditions were performed using passive tracer gas technique together with continuous registration of the room air temperature, the relative humidity and the CO2-concentration using programmable data loggers....

  3. Configuration Management

    International Nuclear Information System (INIS)

    Morcos, A.; Taylor, H. S.

    1989-01-01

    This paper will briefly discuss the reason for and content of configuration management both for new plants and, when adapted, for older plants. It will then address three types of activities a utility may undertake as part of a nuclear CAM program and with which Sargent and Leyden has been actively involved. The first activity is a methodology for preparing design-basis documentation. The second is the identification of essential data required to be kept by the utility in support of the operation of a nuclear plant. The third activity is a computerized classification system of plant components, allowing ready identification of plant functional and physical characteristics. Plant configuration documentation describes plant components, the ways they arranged to interact, and the ways they are enabled to interact. Configuration management, on the other hand, is more than the control of such documentation. It is a dynamic process for ensuring that a plant configuration meets all relevant requirements for safety and economy, even while the configuration changes and even while the requirements change. Configuration management for a nuclear plant is so complex that it must be implemented in phases and modules. It takes advantage of and integrates existing programs. Managing complexity and streamlining the change process become important additional objectives of configuration management. The example activities fulfill essential goals of an overall CAM program: definition of design baseline, definition of essential plant data, and classification of plant components

  4. PV window - Development and demonstrations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Haugaard, P.

    2011-05-15

    Using the results from the EU project RenewTransnet, which focused on the development of a pane with integrated solar cells, the goal of this project is to develop these principles into a window solution. This window solution is targeted to Danish building tradition and architecture. It is expected that an elegant PV-window solution for both new and retrofit buildings is developed during this project, and which appearance can be customized to each building. Based on results from a related projects carried out by Gaia Solar, the window solution will have the potential of being approximately 30% cheaper than similar products on the market. In this project this price reduction is the objective of the development of a window solution. The project team has succeeded in developing a 2-layer PV-window with glass / glass lamination with EVA as foil, which is 35% cheaper than similar products on the market. Since the price for the frame-profile does not differ significantly at market level, the price comparison is made on the basis of the developed PV-pane. The objective of 30 % price reduction in relation to similar products on the market is met. A special production process to the making glass/glass lamination with EVA as foil has been developed, in which a frame is put around the module which intends both to remove the unwanted tension along the edges, and to prevent the significant spillage of EVA from the module under pressure and prevent the invasive bubbles along the edge of module. Since the developed production method for making glass/glass modules with EVA is simple, a further cost reduction will primarily be in a reduction of the price of the cell. The project process has resulted in the development of a product, which due to continuous restrictions in the building regulations, will be very attractive in future buildings. (LN)

  5. Cold Climate Foundation Retrofit Experimental Hygrothermal Performance. Cloquet Residential Research Facility Laboratory Results

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR, St. Paul, MN (United States); Harmon, Anna C. [NorthernSTAR, St. Paul, MN (United States)

    2015-04-09

    This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes. NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. These data currently span the period from November 10, 2012 through May 31, 2014 and are anticipated to be extended through November 2014. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.

  6. In Plan Shear Retrofit of Masonry Walls with Fibre Reinforced Polymer Composites Experimental Investigations

    Directory of Open Access Journals (Sweden)

    Tamás Nagy-György

    2006-01-01

    Full Text Available The paper presents the results from tests on clay brick masonry walls strengthened using fiber reinforced polymer (FRP composites. Five 1.50x1.50 m wall specimens have been subjected to pure in plan shear loads up to failure and then retrofitted on one side, with different types, percentages and lay-ups of the fiber sheets. Based on the experi¬mental results, it was proven the effectiveness of using externally bonded composites for retrofitting brick masonry walls, with less disruption during strengthening, and in this way with reduced costs compared with other conventional repairing and strengthening tech¬niques. Performances of the different strengthening configurations were compared in terms of ultimate load, strain in composite and failure mechanism.

  7. Efficiency and cost effectiveness of retrofitting ventilation in low-rise housing

    International Nuclear Information System (INIS)

    Bowser, D.; Fugler, D.

    2000-01-01

    Effective and inexpensive ventilation systems that can be retrofitted to existing low-rise housing to improve indoor air quality in existing housing stock is discussed. In a project by CMHC ten retrofit ventilation systems in single family residential buildings were tested in an effort to identify homes with specific indoor air quality concerns and to evaluate the performance of these retrofit systems by monitoring air quality before and after installation. Measurements were taken over a two-to-three day period with normal occupancy. In one case radon contamination was also measured directly before and after the retrofit. Cost estimates were based on capital, operating and maintenance expenses. This paper describes the results of three sample case studies. One of these involved a home with high concentration of radon gas. The recommended solution was fan-assisted removal of soil gases as the only way to ensure substantial reductions in concentration. Cost of the system was $2,450, plus $79 annual operating expenses. The second case involved a basement apartment with odour and moisture build-up. To solve the problem, an exhaust-only ventilation system with multiple pick-up points was installed at a cost of $750. Annual operating costs are estimated at $171. The third case study described a dwelling with windows and exhaust ducts showing condensation and mold on the bathroom ceiling. Balanced mechanical ventilation via an HRV was installed to exhaust the moist air from the house and to supply fresh dry air. In this case cost of the system was $1,345 installed, plus annual operating costs of $117. It was stressed that different houses have different requirements. Therefore it is important to be fully aware of the amount of natural ventilation a house has, prior to determining whether the solution demands additional ventilation requirements or simply redistribution. 1 ref., 3 figs

  8. Windows 10 simplified

    CERN Document Server

    McFedries, Paul

    2015-01-01

    Learn Windows 10 quickly and painlessly with this beginner's guide Windows 10 Simplified is your absolute beginner's guide to the ins and outs of Windows. Fully updated to cover Windows 10, this highly visual guide covers all the new features in addition to the basics, giving you a one-stop resource for complete Windows 10 mastery. Every page features step-by-step screen shots and plain-English instructions that walk you through everything you need to know, no matter how new you are to Windows. You'll master the basics as you learn how to navigate the user interface, work with files, create

  9. Windows 10 for dummies

    CERN Document Server

    Rathbone, Andy

    2015-01-01

    The fast and easy way to get up and running with Windows 10 Windows 10 For Dummies covers the latest version of Windows and gets you up and running with the changes and new features you'll find in this updated operating system. Packed with time-saving tips to help you get the most out of the software, this helpful Windows 10 guide shows you how to manage Windows tasks like navigating the interface with a mouse or touchscreen, connecting to the web, and troubleshooting problems and making quick fixes. Assuming no prior knowledge of the software, Windows 10 For Dummies addresses the updates to

  10. Retrofit California Overview and Final Reports

    Energy Technology Data Exchange (ETDEWEB)

    Choy, Howard; Rosales, Ana

    2014-03-01

    Energy efficiency retrofits (also called upgrades) are widely recognized as a critical component to achieving energy savings in the building sector to help lower greenhouse gas (GHG) emissions. To date, however, upgrades have accounted for only a small percentage of aggregate energy savings in building stock, both in California and nationally. Although the measures and technologies to retrofit a building to become energy efficient are readily deployed, establishing this model as a standard practice remains elusive. Retrofit California sought to develop and test new program models to increase participation in the energy upgrade market in California. The Program encompassed 24 pilot projects, conducted between 2010 and mid-2013 and funded through a $30 million American Recovery and Reinvestment Act (ARRA) grant from the U.S. Department of Energy’s (DOE) Better Buildings Neighborhood Program (BBNP). The broad scope of the Program can be seen in the involvement of the following regionally based Grant Partners: Los Angeles County (as prime grantee); Association of Bay Area Governments (ABAG), consisting of: o StopWaste.org for Alameda County o Regional Climate Protection Authority (RCPA) for Sonoma County o SF Environment for the City and County of San Francisco o City of San Jose; California Center for Sustainable Energy (CCSE) for the San Diego region; Sacramento Municipal Utilities District (SMUD). Within these jurisdictions, nine different types of pilots were tested with the common goal of identifying, informing, and educating the people most likely to undertake energy upgrades (both homeowners and contractors), and to provide them with incentives and resources to facilitate the process. Despite its limited duration, Retrofit California undoubtedly succeeded in increasing awareness and education among home and property owners, as well as contractors, realtors, and community leaders. However, program results indicate that a longer timeframe will be needed to

  11. Side-by-Side Field Evaluation of Highly Insulating Windows in the PNNL Lab Homes

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Parker, Graham B.; Baechler, Michael C.; Bauman, Nathan N.

    2012-08-01

    To examine the energy, air leakage, and thermal performance of highly insulating windows, a field evaluation was undertaken in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The “baseline” Lab Home B was retrofitted with “standard” double-pane clear aluminum-frame slider windows and patio doors, while the “experimental” Lab Home A was retrofitted with Jeld-Wen® triple-pane vinyl-frame slider windows and patio doors with a U-factor of 0.2 and solar heat gain coefficient of 0.19. To assess the window, the building shell air leakage, energy use, and interior temperatures of each home were compared during the 2012 winter heating and summer cooling seasons. The measured energy savings in Lab Home B averaged 5,821 watt-hours per day (Wh/day) during the heating season and 6,518 Wh/day during the cooling season. The overall whole-house energy savings of Lab Home B compared to Lab Home A are 11.6% ± 1.53% for the heating season and 18.4 ± 2.06% for the cooling season for identical occupancy conditions with no window coverings deployed. Extrapolating these energy savings numbers based on typical average heating degree days and cooling degree days per year yields an estimated annual energy savings of 12.2%, or 1,784 kWh/yr. The data suggest that highly insulating windows are an effective energy-saving measure that should be considered for high-performance new homes and in existing retrofits. However, the cost effectiveness of the measure, as determined by the simple payback period, suggests that highly insulating window costs continue to make windows difficult to justify on a cost basis alone. Additional reductions in costs via improvements in manufacturing and/or market penetration that continue to drive down costs will make highly insulating windows much more viable as a cost-effective energy efficiency measure. This study also illustrates that highly

  12. The Retrofit Puzzle Extended: Optimal Fleet Owner Behavior over Multiple Time Periods

    Science.gov (United States)

    2009-08-04

    In "The Retrofit Puzzle: Optimal Fleet Owner Behavior in the Context of Diesel Retrofit Incentive Programs" (1) an integer program was developed to model profit-maximizing diesel fleet owner behavior when selecting pollution reduction retrofits. Flee...

  13. RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING

    Directory of Open Access Journals (Sweden)

    Ezgi KORKMAZ

    2013-01-01

    Full Text Available There is a big stock of historic structures in Turkey. Many of those structures continue to serve by changing their functions which brings new loads to the building. During their long life, historic structures have experienced many actions occurred over long periods of time and endured long term deteriorating effects and earthquake loads, besides these effects changing of the function affects the load bearing capacity of the building. This study is focused on restoration and retrofitting of historic multi storey masonry building named Deniz Palace Building which is located in Istanbul where the whole city is seismic prone area itself. Earthquake resistance is the main purpose of decision for retrofitting and strengthening of the building. In this sense walls are sheathed by concrete, floors are strengthened by steel I profiles and concrete, and foundations are reconstructed. During the restoration, interventions are made based on prevention of historic values. Static calculations are done particularly. For this purpose, foundation retrofitting is made primarily and some critical walls are sheathed by concrete. Fire protection system is designed and according to the evacuation plan some additions such as elevator shaft are constructed.

  14. Schematic Window Methodology Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The aim of this IRAD is to produce a generic launch window analyzer (SWM) that allows for large-scale rapid analysis of a launch window and orbit design trade space....

  15. Hypertext Configurations

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2017-01-01

    , links, interactive processes, and time scalings, and that the hypertext configuration is a major but not sole source of the messiness of big data. The notion of hypertext will be revalidated, placed at the center of the interpretation of networked digital media, and used in the analysis of the fast...

  16. Applicability and economic efficiency of earthquake retrofit measures on existing buildings in Bucharest, Romania

    Science.gov (United States)

    Bostenaru, M.

    2009-04-01

    The research discussed in this contribution contains two aspects: on one side the economic efficiency of seismic retrofit measures, and on the other their applicability. The research was limited to housing buildings. Bucharest, the capital of Romania, was the object of the research. Strong earthquakes affect Bucharest about three times in a century, the damaging earthquakes of the 20th century being in 1940 and 1977. Other strong earthquakes occurred in 1986 and 1990. Since it is a broad topic, first the building type was determined, which should serve further research. For this scope the building types of the 20th century, which are common in Bucharest, Romania, were investigated. For each building type reports have been written, which comprised the earthquake resilient features, the seismic defficiencies, the damage patterns and the retrofit measures. Each of these features was listed for elements of the building. A first result of the research was an integrated system in order to include latter aspects in the planning in the first steps. So already at the building survey attention has to be paid on how a building is subdivided in order to be able to determine the economic efficiency of the planned action. So were defined the `retrofit elements`. In a first step the characteristics were defined, through which these retrofit elements (for example column, wall part between two windows) can be recognised in the building survey. In a further one, which retrofit measures can be connected to these. Diagrams were built, in order to visualise these findings. For each retrofit element and the corresponding measure the costs were calculated. Also, these retrofit elements and the measures connected to them were modelled for the simulation with the structural software, so that the benefit of the measures could be determined. In the part which regarded the economic efficiency, benefits and costs of retrofit measures had to be compared, so the improvement in the rigidity

  17. Ready to Retrofit: The Process of Project Team Selection, Building Benchmarking, and Financing Commercial Building Energy Retrofit Projects

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, Mark D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Parrish, Kristen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mathew, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-05-01

    This guide presents a process for three key activities for the building owner in preparing to retrofit existing commercial buildings: selecting project teams, benchmarking the existing building, and financing the retrofit work. Although there are other essential steps in the retrofit process, the three activities presented in this guide are the critical elements where the building owner has the greatest influence on the outcome of the project.

  18. Pengaruh Window Level Dan Window Width Pada Lung Window Dan Mediastinum Window Pada Kualitas Citra CT-Scan Thorax

    OpenAIRE

    Gaol, Syahnaro Lumban

    2015-01-01

    This Research of image CT-SCAN thorax with influence of window level and window width, to obtain, get value of window level and optimal window width lung window and mediastinum window, so that get image of CT-SCAN thorax which with image quality. Image of CT-SCAN thorax obtained for mediastinum window use window width 350, 400, 450, 500 HU. And Window level 50,100,150 HU. While for lung window use window width 1000,1100 HU. The window level - 500-,600,-700,-800,-900,-1000 HU, by three observe...

  19. Energy performance of windows based on the net energy gain

    DEFF Research Database (Denmark)

    Svendsen, Svend; Kragh, Jesper; Laustsen, Jacob Birck

    2005-01-01

    The paper presents a new method to set up energy performance requirements and energy classes for windows of all dimensions and configurations. The net energy gain of windows is the solar gain minus the heat loss integrated over the heating season. The net energy gain can be calculated for one...... orientation or averaged over different orientations. The averaged value may be used for energy labeling of windows of standard size. Requirements in building codes may also be based on the net energy gain instead of the thermal transmittance of the window. The size and the configuration of the window, i.......e. number of glazing units, have a very large effect on the net energy gain. Therefore the energy labeling or the requirements based on the standard size may not give valid information on the energy performance of windows of non-standard size. The paper presents a method to set up requirements and classes...

  20. Windows for Intel Macs

    CERN Document Server

    Ogasawara, Todd

    2008-01-01

    Even the most devoted Mac OS X user may need to use Windows XP, or may just be curious about XP and its applications. This Short Cut is a concise guide for OS X users who need to quickly get comfortable and become productive with Windows XP basics on their Macs. It covers: Security Networking ApplicationsMac users can easily install and use Windows thanks to Boot Camp and Parallels Desktop for Mac. Boot Camp lets an Intel-based Mac install and boot Windows XP on its own hard drive partition. Parallels Desktop for Mac uses virtualization technology to run Windows XP (or other operating systems

  1. Windows® Internals

    CERN Document Server

    Russinovich, Mark E; Ionescu, Alex

    2009-01-01

    See how the core components of the Windows operating system work behind the scenes-guided by a team of internationally renowned internals experts. Fully updated for Windows Server 2008 and Windows Vista, this classic guide delivers key architectural insights on system design, debugging, performance, and support-along with hands-on experiments to experience Windows internal behavior firsthand.Delve inside Windows architecture and internals:Understand how the core system and management mechanisms work-from the object manager to services to the registryExplore internal system data structures usin

  2. Design and application of CVD diamond windows for x-rays at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Jaski, Y.; Cookson, D.

    2007-01-01

    Two types of directly cooled, 0.2-mm-thick, 8-mm-diameter clear aperture CVD diamond windows have been designed and successfully fabricated by two different vendors for use at the Advanced Photon Source (APS). Both windows contain a direct braze joint between the diamond and the cooled OFHC copper. These windows can be used to replace the front-end beryllium windows in high-heat-load applications and can be used as white beam windows in the beamlines. This paper presents the detailed design of the diamond windows, the thermal analysis of the diamond window under different thermal load configurations, as well as a complete list of the existing APS front-end beryllium window configurations and replacement scenarios. Small-angle scattering experiments have been conducted on both diamond windows and a polished beryllium window, and the results are presented.

  3. Design and Application of CVD Diamond Windows for X-Rays at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Jaski, Yifei; Cookson, David

    2007-01-01

    Two types of directly cooled, 0.2-mm-thick, 8-mm-diameter clear aperture CVD diamond windows have been designed and successfully fabricated by two different vendors for use at the Advanced Photon Source (APS). Both windows contain a direct braze joint between the diamond and the cooled OFHC copper. These windows can be used to replace the front-end beryllium windows in high-heat-load applications and can be used as white beam windows in the beamlines. This paper presents the detailed design of the diamond windows, the thermal analysis of the diamond window under different thermal load configurations, as well as a complete list of the existing APS front-end beryllium window configurations and replacement scenarios. Small-angle scattering experiments have been conducted on both diamond windows and a polished beryllium window, and the results are presented

  4. Advanced energy efficient windows

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund

    2007-01-01

    energy savings. In terms of energy, windows occupy a special position compared with other thermal envelope structures due to their many functions: 1) windows let daylight into the building and provide occupants with visual contact with their surroundings 2) windows protect against the outdoor climate 3......) windows transmit solar energy that may contribute to a reduction of energy consumption, but which may also lead to unpleasant overheating. In the following paragraphs the current use of windows is reviewed with an emphasis on energy, while special products like solar protection glazing and security......Windows should be paid special attention as they contribute a significant part of the total heat-loss coefficient of the building. Contrary to other parts of the thermal envelope the windows are not only heat loosers, but may gain heat in the day-time. Therefore there are possibilities for large...

  5. Microsoft Windows Server 2003: Security Enhancements and New Features

    Science.gov (United States)

    2004-09-01

    a central location. With the Fax Service Manager in the Windows Server 2003 family, systems administrators can configure fax devices, and share fax...the Services can be configured for activity logging to track the use of fax resources. Fax Service Manager in Windows Server 2003 is a Microsoft...connection. Fax Service Manager improves the managing of Fax Service, but, systems administrators must install Fax Service because it is not installed

  6. Arkansas Solar Retrofit Guide. Greenhouses, Air Heaters and Water Heaters.

    Science.gov (United States)

    Skiles, Albert; Rose, Mary Jo

    Solar retrofits are devices of structures designed to be attached to existing buildings to augment their existing heating sources with solar energy. An investigation of how solar retrofits should be designed to suit the climate and resources of Arkansas is the subject of this report. Following an introduction (section 1), section 2 focuses on…

  7. IMPROVEMENT TO PIPELINE COMPRESSOR ENGINE RELIABILITY THROUGH RETROFIT MICRO-PILOT IGNITION SYSTEM -- PHASE III

    Energy Technology Data Exchange (ETDEWEB)

    Scott Chase; Daniel Olsen; Ted Bestor

    2005-03-01

    This report documents the third year's effort towards a 3-year program conducted by the Engines & Energy Conversion Laboratory (EECL) at Colorado State University (CSU) to develop micropilot ignition systems for existing pipeline compressor engines. Research activities for the overall program were conducted with the understanding that the efforts are to result in a commercial product to capture and disseminate the efficiency and environmental benefits of this new technology. Commercially-available fuel injection products were identified and applied to the program where appropriate. This approach will minimize the overall time-to-market requirements, while meeting performance and cost criteria. Two earlier phases of development precede this report. The objective for Phase I was to demonstrate the feasibility of retrofit micropilot ignition (RMI) systems for large bore, slow speed engines operating at low compression ratios under laboratory conditions at the EECL. The objective for Phase II was to further develop and optimize the micropilot ignition system at the EECL for large bore, slow speed engines operating at low compression ratios. These laboratory results were enhanced, then verified via a field demonstration project during Phase III of the Micropilot Ignition program. An Implementation Team of qualified engine retrofit service providers was assembled to install the retrofit micropilot ignition system for an engine operated by El Paso Pipeline Group at a compressor station near Window Rock, Arizona. Testing of this demonstration unit showed that the same benefits identified by laboratory testing at CSU, i.e., reduced fuel consumption and exhaust emissions (NOx, THC, CO, and CH2O). Installation efforts at Window Rock were completed towards the end of the budget period, which did not leave sufficient time to complete the durability testing. These efforts are ongoing, with funding provided by El Paso Pipeline Group, and the results will be documented in a

  8. High Power Coax Window

    International Nuclear Information System (INIS)

    Neubauer, M.L.; Dudas, A.; Sah, R.; Elliott, T.S.; Rimmer, R.A.; Stirbet, M.

    2010-01-01

    A superconducting RF (SRF) power coupler capable of handling 500 kW CW RF power is required for present and future storage rings and linacs. There are over 35 coupler designs for SRF cavities ranging in frequency from 325 to 1500 MHz. Coupler windows vary from cylinders to cones to disks, and RF power couplers are limited by the ability of ceramic windows to withstand the stresses due to heating and mechanical flexure. We propose a novel robust co-axial SRF coupler design which uses compressed window technology. This technology will allow the use of highly thermally conductive materials for cryogenic windows. Using compressed window techniques on disk co-axial windows will make significant improvements in the power handling of SRF couplers. We present the bench test results of two window assemblies back to back, as well as individual window VSWR in EIA3.125 coax. A vacuum test assembly was made and the windows baked out at 155C. The processes used to build windows is scalable to larger diameter coax and to higher power levels.

  9. Multicriteria decision model for retrofitting existing buildings

    Science.gov (United States)

    Bostenaru Dan, B.

    2003-04-01

    In this paper a model to decide which buildings from an urban area should be retrofitted is presented. The model has been cast into existing ones by choosing the decision rule, criterion weighting and decision support system types most suitable for the spatial problem of reducing earthquake risk in urban areas, considering existing spatial multiatributive and multiobjective decision methods and especially collaborative issues. Due to the participative character of the group decision problem "retrofitting existing buildings" the decision making model is based on interactivity. Buildings have been modeled following the criteria of spatial decision support systems. This includes identifying the corresponding spatial elements of buildings according to the information needs of actors from different sphaeres like architects, construction engineers and economists. The decision model aims to facilitate collaboration between this actors. The way of setting priorities interactivelly will be shown, by detailing the two phases: judgemental and computational, in this case site analysis, collection and evaluation of the unmodified data and converting survey data to information with computational methods using additional expert support. Buildings have been divided into spatial elements which are characteristic for the survey, present typical damages in case of an earthquake and are decisive for a better seismic behaviour in case of retrofitting. The paper describes the architectural and engineering characteristics as well as the structural damage for constuctions of different building ages on the example of building types in Bucharest, Romania in compressible and interdependent charts, based on field observation, reports from the 1977 earthquake and detailed studies made by the author together with a local engineer for the EERI Web Housing Encyclopedia. On this base criteria for setting priorities flow into the expert information contained in the system.

  10. The economics of window selection: An incremental approach

    International Nuclear Information System (INIS)

    Dixon, W.T.

    1993-01-01

    The options available to Energy Service Companies when improving the energy performance of an existing building are often driven by short-term payback cycles. The value of a measure is based on how quickly it pays for itself. The more quickly the energy savings created by the measure exceed the cost of purchasing and installing the measure, the more comfortable the engineer feels recommending that improvement. In the best cases, the short-term approach will quickly retire the debts associated with a particular retrofit and provide a dependable, albeit limited net savings stream for the property owner. The engineer has obtained energy savings for his client. The problem with this short-term approach is that it automatically eliminates other conservation measures which, over longer time horizons, could add far more value for the customer. The installation of new, extremely energy efficient replacement windows is a case in point. During preliminary discussions with our clients, (typically Public Housing Authorities or owners of subsidized, multi-family housing), the conversation eventually turns to the issue of replacement windows. The perception is that new windows are a luxury. The decision to install new windows is driven by maintenance costs and, in some cases, resident complaints over operability or draftiness associated with the existing windows. Typically the windows are not handled as part of the mainstream energy conservation program. If the client has already installed new windows, he probably based his selection on the low bidder of a unit that has marginal thermal performance. Every property has a budget and compromises must often be made to meet budgets. The purchaser may have not gotten the Cadillac of windows, but at least he got a good deal on the window that he did buy. His maintenance problems have been solved for the near term and resident complaints have gone down, for now

  11. Measure Guideline: Hybrid Foundation Insulation Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Lstiburek, J.

    2012-05-01

    This measure guideline provides recommendations for designs and variations for retrofit hybrid assemblies in improving interior foundation insulation and water management of basements. Variations include closed cell spray foam (ccSPF) with membrane waterproofing or air gap membrane drainage layers, rigid board foam insulation at flat walls (cast concrete or CMU block), a 'partial drainage' detail making use of the bulk water drainage that occurs through the field of a rubble stone wall, and non-drained spray foam assemblies (including slab insulation).

  12. Measure Guideline. Hybrid Foundation Insulation Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Somerville, MA (United States); Lstiburek, J. [Building Science Corporation, Somerville, MA (United States)

    2012-05-01

    This measure guideline provides recommendations for designs and variations for retrofit hybrid assemblies in improving interior foundation insulation and water management of basements. Variations include closed cell spray foam (ccSPF) with membrane waterproofing or air gap membrane drainage layers, rigid board foam insulation at flat walls (cast concrete or CMU block), a “partial drainage” detail making use of the bulk water drainage that occurs through the field of a rubble stone wall, and non-drained spray foam assemblies (including slab insulation).

  13. Crowne Plaza Renovation Retrofit Case Study

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-03-01

    InterContinental Hotels Group (IHG) and its franchise partner B.F. Saul Company Hospitality Group (B.F. Saul Co.) partnered with the Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% versus requirements set by Standard 90.1-2004 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) Program.

  14. Retrofitting compressor engines to reduce emissions

    International Nuclear Information System (INIS)

    Collison, Melanie

    2011-01-01

    Cenovus Energy Inc. is upgrading its natural gas compression facilities at 37 sites it operates in Alberta. The project itself consists of a retrofit of the natural-fas fired engines that power the compressors that fill its natural gas sales pipe-line. Piping to capture fugitive natural gas will also be installed. These emissions will be used as fuel. The efficiency rating of such engine will be the same as a new fuel-injected engine. One of the challenge in the design of the parts of these engines ss to to ensure the least possible downtime to minimize production losses.

  15. Design Concept for the Retrofit KAO 1m Robotic Telescope

    Directory of Open Access Journals (Sweden)

    Wonyong Han

    2000-12-01

    Full Text Available Korea Astronomy Observatory (KAO is working to retrofit its 1m robotic telescope in collaboration with a company (ACE, Astronomical Consultants & Equipment. The telescope system is being totally refurbished to make a fully automatic telescope which can operate in both interactive and fully autonomous robotic modes. Progress has been made in design and manufacturing of the telescope mount, mechanics, and optical performance system tests are being made for re-configured primary and secondary mirrors. The optical system is designed to collect 80% incident light within 0.5 arcsec with f/7.5 Ritchey-Chretien design. The telescope mount is an equatorial fork with a friction drive system. The design allows fully programmable tracking speeds with typical range of 15 arcsec/sec with accuracy of +/-5 arcsec/hour. The mount system has integral pointing model software to correct for refraction, and all mechanical errors and misalignments. The pointing model will permit positioning to better than 30 arcsec RMS within 75o from zenith and 45 arcsec RMS elsewhere on the sky. The software is designed for interactive, remote and robotic modes of operation. In interactive and remote mode the user can manually enter coordinates or retrieve them from a computer file. In robotic mode the telescope controller downloads the coordinates in the order determined by the scheduler. The telescope will be equipped with a CCD camera and will be accessible via the internet.

  16. Indoor climate in renovated and energy retrofitted social housing

    DEFF Research Database (Denmark)

    Knudsen, Henrik Nellemose; Jensen, Ole Michael

    2016-01-01

    The need for energy retrofitting of the Danish single-family houses is massive, especially for the high proportion of single-family houses built in the 1960s and 1970s. But even though the potential benefits are many, only few families embark on a major energy retrofit. There may be many reasons...... for this. An obvious one may be limited knowledge of non-energy benefits, e.g. in relation to the indoor climate. The objective of this study was to explain this limited effort to save energy by identifying barriers and incentives among house owners in relation to energy retrofitting of one’s own house....... Moreover, it was investigated among house owners, who had carried out energy retrofitting, whether a number of factors, including the perceived indoor climate, became better or worse after retrofitting. A questionnaire survey was carried out among 1,990 house owners in a municipality north of Copenhagen...

  17. Building America Case Study: Pilot Demonstration of Phased Energy Efficiency Retrofits: Deep Retrofits, Central and South Florida

    Energy Technology Data Exchange (ETDEWEB)

    2017-02-22

    The Florida Solar Energy Center (FSEC), in collaboration with Florida Power & Light (FPL), is pursuing a phased residential energy-efficiency retrofit program in Florida. Researchers are looking to establish the impacts of technologies of two retrofit packages -- shallow and deep -- on annual energy and peak energy reductions.

  18. Building America Case Study: Pilot Demonstration of Phased Energy Efficiency Retrofits: Deep Retrofits, Central and South Florida

    Energy Technology Data Exchange (ETDEWEB)

    D. Parker, K. Sutherland, D. Chasar, J. Montemurno, B. Amos, J. Kono

    2017-02-01

    The Florida Solar Energy Center (FSEC), in collaboration with Florida Power & Light (FPL), is pursuing a phased residential energy-efficiency retrofit program in Florida. Researchers are looking to establish the impacts of technologies of two retrofit packages -- shallow and deep -- on annual energy and peak energy reductions.

  19. Windows 8 secrets

    CERN Document Server

    Thurrott, Paul

    2012-01-01

    Tips, tricks, treats, and secrets revealed on Windows 8 Microsoft is introducing a major new release of its Windows operating system, Windows 8, and what better way to learn all its ins and outs than from two internationally recognized Windows experts and Microsoft insiders, authors Paul Thurrott and Rafael Rivera? They cut through the hype to get at useful information you'll not find anywhere else, including what role this new OS plays in a mobile and tablet world. Regardless of your level of knowledge, you'll discover little-known facts about how things work, what's new and different, and h

  20. Programming Windows Azure

    CERN Document Server

    Krishnan, Sriram

    2010-01-01

    Learn the nuts and bolts of cloud computing with Windows Azure, Microsoft's new Internet services platform. Written by a key member of the product development team, this book shows you how to build, deploy, host, and manage applications using Windows Azure's programming model and essential storage services. Chapters in Programming Windows Azure are organized to reflect the platform's buffet of services. The book's first half focuses on how to write and host application code on Windows Azure, while the second half explains all of the options you have for storing and accessing data on the plat

  1. Windows Powershell Pocket Reference

    CERN Document Server

    Holmes, Lee

    2009-01-01

    This portable reference to Windows PowerShell summarizes both the command shell and scripting language, and provides a concise reference to the major tasks that make PowerShell so successful. Written by Microsoft PowerShell team member Lee Holmes, and excerpted from his Windows PowerShell Cookbook, Windows PowerShell Pocket Reference offers up-to-date coverage of PowerShell's 1.0 release. It's an ideal on-the-job tool for Windows administrators who don't have time to plow through huge books or search online.

  2. Beginning Windows 8

    CERN Document Server

    Halsey, Mike

    2012-01-01

    Windows 8 has been described by Microsoft as its 'boldest' Windows release ever. Beginning Windows 8 takes you through the new features and helps you get more out of the familiar to reveal the possibilities for this amazing new operating system. You will learn, with non-technical language used throughout, how to get up and running in the new Windows interface, minimize downtime, maximize productivity, and harness the features you never knew existed to take control of your computer and enjoy the peace of mind and excitement that comes with it. From tips and tweaks to easy-to-follow guides and d

  3. Mastering Windows 7 Deployment

    CERN Document Server

    Finn, Aidan; van Surksum, Kenneth

    2011-01-01

    Get professional-level instruction on Windows 7 deployment tools Enterprise-level operating system deployment is challenging and requires knowledge of specific tools. It is expected that Windows 7 will be extensively deployed in businesses worldwide. This comprehensive Sybex guide provides thorough coverage of the Microsoft deployment tools that were specifically created for Windows 7, preparing system administrators, MIS professionals, and corporate programmers to tackle the task effectively.Companies worldwide are expected to deploy Windows 7 as their enterprise operating system; system admi

  4. Deep Energy Retrofits - Eleven California Case Studies

    Energy Technology Data Exchange (ETDEWEB)

    Less, Brennan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisher, Jeremy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-10-01

    This research documents and demonstrates viable approaches using existing materials, tools and technologies in owner-conducted deep energy retrofits (DERs). These retrofits are meant to reduce energy use by 70% or more, and include extensive upgrades to the building enclosure, heating, cooling and hot water equipment, and often incorporate appliance and lighting upgrades as well as the addition of renewable energy. In this report, 11 Northern California (IECC climate zone 3) DER case studies are described and analyzed in detail, including building diagnostic tests and end-use energy monitoring results. All projects recognized the need to improve the home and its systems approximately to current building code-levels, and then pursued deeper energy reductions through either enhanced technology/ building enclosure measures, or through occupant conservation efforts, both of which achieved impressive energy performance and reductions. The beyond-code incremental DER costs averaged $25,910 for the six homes where cost data were available. DERs were affordable when these incremental costs were financed as part of a remodel, averaging a $30 per month increase in the net-cost of home ownership.

  5. Air Distribution Retrofit Strategies for Affordable Housing

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Conlin, Francis [National Renewable Energy Lab. (NREL), Golden, CO (United States); Holloway, Parker [National Renewable Energy Lab. (NREL), Golden, CO (United States); Podorson, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Varshney, Kapil [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  6. Air Distribution Retrofit Strategies for Affordable Housing

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Conlin, F. [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Holloway, Parker [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Podorson, David [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Varshney, Kapil [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States)

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  7. Simulating Performance Risk for Lighting Retrofit Decisions

    Directory of Open Access Journals (Sweden)

    Jia Hu

    2015-05-01

    Full Text Available In building retrofit projects, dynamic simulations are performed to simulate building performance. Uncertainty may negatively affect model calibration and predicted lighting energy savings, which increases the chance of default on performance-based contracts. Therefore, the aim of this paper is to develop a simulation-based method that can analyze lighting performance risk in lighting retrofit decisions. The model uses a surrogate model, which is constructed by adaptively selecting sample points and generating approximation surfaces with fast computing time. The surrogate model is a replacement of the computation intensive process. A statistical method is developed to generate extreme weather profile based on the 20-year historical weather data. A stochastic occupancy model was created using actual occupancy data to generate realistic occupancy patterns. Energy usage of lighting, and heating, ventilation, and air conditioning (HVAC is simulated using EnergyPlus. The method can evaluate the influence of different risk factors (e.g., variation of luminaire input wattage, varying weather conditions on lighting and HVAC energy consumption and lighting electricity demand. Probability distributions are generated to quantify the risk values. A case study was conducted to demonstrate and validate the methods. The surrogate model is a good solution for quantifying the risk factors and probability distribution of the building performance.

  8. Design of traveling wave windows for the PEP-II RF coupling network

    International Nuclear Information System (INIS)

    Kroll, N.M.; Ng, C.K.; Judkins, J.; Neubauer, M.

    1995-05-01

    The waveguide windows in the PEP-II RF coupling network have to withstand high power of 500 kW. Traveling wave windows have lower power dissipation than conventional self-matched windows, thus rendering the possibility of less stringent mechanical design. The traveling wave behavior is achieved by providing a reflecting iris on each side of the window, and depending on the configuration of the irises, traveling wave windows are characterized as inductive or capacitive types. A numerical design procedure using MAFIA has been developed for traveling wave windows. The relative advantages of inductive and capacitive windows are discussed. Furthermore, the issues of bandwidth and multipactoring are also addressed

  9. Efficient Windows Collaborative

    Energy Technology Data Exchange (ETDEWEB)

    Nils Petermann

    2010-02-28

    The project goals covered both the residential and commercial windows markets and involved a range of audiences such as window manufacturers, builders, homeowners, design professionals, utilities, and public agencies. Essential goals included: (1) Creation of 'Master Toolkits' of information that integrate diverse tools, rating systems, and incentive programs, customized for key audiences such as window manufacturers, design professionals, and utility programs. (2) Delivery of education and outreach programs to multiple audiences through conference presentations, publication of articles for builders and other industry professionals, and targeted dissemination of efficient window curricula to professionals and students. (3) Design and implementation of mechanisms to encourage and track sales of more efficient products through the existing Window Products Database as an incentive for manufacturers to improve products and participate in programs such as NFRC and ENERGY STAR. (4) Development of utility incentive programs to promote more efficient residential and commercial windows. Partnership with regional and local entities on the development of programs and customized information to move the market toward the highest performing products. An overarching project goal was to ensure that different audiences adopt and use the developed information, design and promotion tools and thus increase the market penetration of energy efficient fenestration products. In particular, a crucial success criterion was to move gas and electric utilities to increase the promotion of energy efficient windows through demand side management programs as an important step toward increasing the market share of energy efficient windows.

  10. The windows method

    DEFF Research Database (Denmark)

    Neighbour, Roger; Larsen, Jan-Helge

    2017-01-01

    through in sequence, each one opening a different viewpoint or window on the case. To experienced tutors, the windows method’s prescriptive structure may at first seem somewhat rigid. However, for learners with less experience of reflection and self-disclosure, it provides the security necessary...

  11. Color Wheel Windows

    Science.gov (United States)

    Leonard, Stephanie

    2012-01-01

    In this article, the author describes a painting and drawing lesson which was inspired by the beautiful circular windows found in cathedrals and churches (also known as "rose windows"). This two-week lesson would reinforce both the concept of symmetry and students' understanding of the color wheel. (Contains 1 online resource.)

  12. The Luminaire Window

    DEFF Research Database (Denmark)

    Hansen, Ellen Kathrine; Horóczi, Eszter

    2017-01-01

    integrated into the window. A qualitative experiment is carried out by integrating controllable LED in the frame of a façade window in a full-scale mock-up. It is examined how this set-up can support the colour spectrum and intensity of the daylight intake during the transmission time from daylight...

  13. Air transparent soundproof window

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang-Hoon, E-mail: shkim@mmu.ac.kr [Division of Marine Engineering, Mokpo National Maritime University, Mokpo 530-729, R. O. Korea (Korea, Republic of); Lee, Seong-Hyun [Korea Institute of Machinery and Materials, Yuseong-Gu, Daejeon 305-343, R. O. Korea (Korea, Republic of)

    2014-11-15

    A soundproof window or wall which is transparent to airflow is presented. The design is based on two wave theories: the theory of diffraction and the theory of acoustic metamaterials. It consists of a three-dimensional array of strong diffraction-type resonators with many holes centered on each individual resonator. The negative effective bulk modulus of the resonators produces evanescent wave, and at the same time the air holes with subwavelength diameter existed on the surfaces of the window for macroscopic air ventilation. The acoustic performance levels of two soundproof windows with air holes of 20mm and 50mm diameters were measured. The sound level was reduced by about 30 - 35dB in the frequency range of 400 - 5,000Hz with the 20mm window, and by about 20 - 35dB in the frequency range of 700 - 2,200Hz with the 50mm window. Multi stop-band was created by the multi-layers of the window. The attenuation length or the thickness of the window was limited by background noise. The effectiveness of the soundproof window with airflow was demonstrated by a real installation.

  14. Air transparent soundproof window

    Directory of Open Access Journals (Sweden)

    Sang-Hoon Kim

    2014-11-01

    Full Text Available A soundproof window or wall which is transparent to airflow is presented. The design is based on two wave theories: the theory of diffraction and the theory of acoustic metamaterials. It consists of a three-dimensional array of strong diffraction-type resonators with many holes centered on each individual resonator. The negative effective bulk modulus of the resonators produces evanescent wave, and at the same time the air holes with subwavelength diameter existed on the surfaces of the window for macroscopic air ventilation. The acoustic performance levels of two soundproof windows with air holes of 20mm and 50mm diameters were measured. The sound level was reduced by about 30 - 35dB in the frequency range of 400 - 5,000Hz with the 20mm window, and by about 20 - 35dB in the frequency range of 700 - 2,200Hz with the 50mm window. Multi stop-band was created by the multi-layers of the window. The attenuation length or the thickness of the window was limited by background noise. The effectiveness of the soundproof window with airflow was demonstrated by a real installation.

  15. Visual merchandising window display

    Directory of Open Access Journals (Sweden)

    Opris (Cas. Stanila M.

    2013-12-01

    Full Text Available Window display plays a major part in the selling strategies; it does not only include the simple display of goods, nowadays it is a form of art, also having the purpose of sustaining the brand image. This article wants to reveal the tools that are essential in creating a fabulous window display. Being a window designer is not an easy job, you have to always think ahead trends, to have a sense of colour, to know how to use light to attract customers in the store after only one glance at the window. The big store window displays are theatre scenes: with expensive backgrounds, special effects and high fashion mannequins. The final role of the displays is to convince customers to enter the store and trigger the purchasing act which is the final goal of the retail activity.

  16. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, K. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Parker, D. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Martin, E. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Chasar, D. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Amos, B. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2016-12-01

    Originally published in February 2016, this revision contains an added section called 'Evaluation of Complete Central System Replacement with Inverter-Driven Heat Pump,' which presents the designs and energy savings evaluations of two different schemes wherein inverter-driven systems replaced a home’s existing central system. Analyses for three additional retrofit measures were bolstered by longer-term data; these are described in the sections on supplemental mini-split heat pumps (MSHPs), smart thermostats, and heat pump clothes dryers. The sections on supplemental MSHPs and smart thermostats were also enhanced with larger sample sizes and projections of weather-normalized annual energy savings. Finally, peak system hour energy demand-reduction predictions are provided for all retrofit measures where meaningful impacts could be drawn.

  17. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, K. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Parker, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Martin, E. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Chasar, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Amos, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-12-01

    Originally published in February 2016, this revision contains an added section called 'Evaluation of Complete Central System Replacement with Inverter-Driven Heat Pump,' which presents the designs and energy savings evaluations of two different schemes wherein inverter-driven systems replaced a home's existing central system. Analyses for three additional retrofit measures were bolstered by longer-term data; these are described in the sections on supplemental mini-split heat pumps (MSHPs), smart thermostats, and heat pump clothes dryers. The sections on supplemental MSHPs and smart thermostats were also enhanced with larger sample sizes and projections of weather-normalized annual energy savings. Finally, peak system hour energy demand-reduction predictions are provided for all retrofit measures where meaningful impacts could be drawn.

  18. Window Size Impact in Human Activity Recognition

    Directory of Open Access Journals (Sweden)

    Oresti Banos

    2014-04-01

    Full Text Available Signal segmentation is a crucial stage in the activity recognition process; however, this has been rarely and vaguely characterized so far. Windowing approaches are normally used for segmentation, but no clear consensus exists on which window size should be preferably employed. In fact, most designs normally rely on figures used in previous works, but with no strict studies that support them. Intuitively, decreasing the window size allows for a faster activity detection, as well as reduced resources and energy needs. On the contrary, large data windows are normally considered for the recognition of complex activities. In this work, we present an extensive study to fairly characterize the windowing procedure, to determine its impact within the activity recognition process and to help clarify some of the habitual assumptions made during the recognition system design. To that end, some of the most widely used activity recognition procedures are evaluated for a wide range of window sizes and activities. From the evaluation, the interval 1–2 s proves to provide the best trade-off between recognition speed and accuracy. The study, specifically intended for on-body activity recognition systems, further provides designers with a set of guidelines devised to facilitate the system definition and configuration according to the particular application requirements and target activities.

  19. Measure Guideline. Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls

    Energy Technology Data Exchange (ETDEWEB)

    Musunuru, S. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-04-30

    This Measure Guideline describes a deep energy enclosure retrofit solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits might adversely affect the durability of the wall. This guideline includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage.

  20. Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls

    Energy Technology Data Exchange (ETDEWEB)

    Musunuru, S. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-04-01

    This Measure Guideline describes a deep energy enclosure retrofit (DEER) solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits has the potential to adversely affect the durability of the wall; this document includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage.

  1. Selecting windows for energy efficiency

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    New window technologies have increased energy benefits and comfort, and have provided more practical options for consumers. This selection guide will help homeowners, architects, and builders take advantage of the expanding window market. The guide contains three sections: an explanation of energy-related window characteristics, a discussion of window energy performance ratings, and a convenient checklist for window selection.

  2. Amelioration and retrofitting of educational buildings

    Science.gov (United States)

    Casciati, Fabio; Casciati, Sara

    2018-01-01

    Following a seismic event that occurred years ago in Central Italy, the public opinion was growing and growing a concern on the adequacy of educational buildings all across Italy. This activated several political decisions and a consequent technical effort is in progress. Technically speaking one has to manage the classical problem of retrofitting existing buildings. However, the legal environment goes across national codes, targeted guidelines and the professional need of achieving pragmatic solutions based on ethical and social acceptation schemes.This paper introduces the topic in its worldwide exception and focuses then on some operative aspects in the Italian situation. It outlines the consolidated steps along this technical process and emphasizes the weak aspects one meets when going across the designers' reports.

  3. Retrofitting reciprocating compressors for noise control

    International Nuclear Information System (INIS)

    Frank, L.; Qualfe, R.

    1992-01-01

    The Alberta Energy Resources Conservation Board recently enacted their noise control directive ID 88-1. The effects of this regulation on the operation of an oil and gas facility are discussed, and a specific case history is presented to provide a disciplined strategy for noise attenuation retrofits. An investigation was carried out into sound sources at a reciprocating compressor gas plant, revealing several sound sources: engine exhaust stacks, engine exhaust silencer shells, direct-drive fan cooler inlets, direct drive fan cooler outlets, aerial cooler inlets and aerial cooler outlets. Details are presented of the investigative techniques and order-ranking of sources by decibel level. When controlling engine exhaust noise, silencers or mufflers are the preferred treatment. Choice of type (reactive or absorptive) and specification of acoustical performance of a silencer are discussed. The gas plant achieved noise reductions of 6-13 dB, measured at affected residences, through the use of engine exhaust silencers. 4 figs., 2 tabs

  4. Retrofitting the Southeast. The Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    Zoeller, W. [Steven Winter Associates, Inc., Norwalk, CT (United States); Shapiro, C. [Steven Winter Associates, Inc., Norwalk, CT (United States); Vijayakumar, G. [Steven Winter Associates, Inc., Norwalk, CT (United States); Puttagunta, S. [Steven Winter Associates, Inc., Norwalk, CT (United States)

    2013-02-01

    The Consortium for Advanced Residential Buildings research team has provided the technical engineering and building science support for a highly visible demonstration home that was unveiled at the National Association of Home Builders' International Builders Show on Feb. 9, 2012, in Orlando, FL. The two previous projects, the Las Vegas net-zero ReVISION House and the 2011 VISION and ReVISION Houses in Orlando, met goals for energy efficiency, cost effectiveness, and information dissemination through multiple web-based venues. This report describes the deep energy retrofit of the Cool Energy House (CEH), which began as a mid-1990s two-story traditional specification house of about 4,000 ft2 in the upscale Orlando suburb of Windermere.

  5. Retrofitting the Southeast: The Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    Zoeller, W.; Shapiro, C.; Vijayakumar, G.; Puttagunta, S.

    2013-02-01

    The Consortium for Advanced Residential Buildings has provided the technical engineering and building science support for a highly visible demonstration home in connection with the National Association of Home Builders' International Builders Show. The two previous projects, the Las Vegas net-zero ReVISION House and the 2011 VISION and ReVISION Houses in Orlando, met goals for energy efficiency, cost effectiveness, and information dissemination through multiple web-based venues. This project, which was unveiled at the 2012 International Builders Show in Orlando on February 9, is the deep energy retrofit Cool Energy House (CEH). The CEH began as a mid-1990s two-story traditional specification house of about 4,000 ft2 in the upscale Orlando suburb of Windermere.

  6. GA microwave window development

    International Nuclear Information System (INIS)

    Moeller, C.P.; Kasugai, A.; Sakamoto, K.; Takahashi, K.

    1994-10-01

    The GA prototype distributed window was tested in a 32 mm diam. waveguide system at a power density suitable for a MW gyrotron, using the JAERI/Toshiba 110 GHz long pulse internal converter gyrotron in the JAERI test stand. The presence of the untilted distributed window had no adverse effect on the gyrotron operation. A pulse length of 10 times the calculated thermal equilibrium time (1/e time) of 30 msec was reached, and the window passed at least 750 pulses greater than 30 msec and 343 pulses greater than 60 msec. Beyond 100 msec, the window calorimetry reached steady state, allowing the window dissipation to be measured in a single pulse. The measured loss of 4.0% agrees both with the estimated loss, on which the stress calculations are based, and with the attenuation measured at low power in the HE 11 mode. After the end of the tests, the window was examined; no evidence of arcing air coating was found in the part of the window directly illuminated by the microwaves, although there was discoloration in a recess containing an optical diagnostic which outgassed, causing a local discharge to occur in that recess. Finally, there was no failure of the metal-sapphire joints during a total operating time of 50 seconds consisting of pulses longer than 30 msec

  7. Retrofitting Domestic Hot Water Heaters for Solar Water Heating Systems in Single-Family Houses in a Cold Climate: A Theoretical Analysis

    Directory of Open Access Journals (Sweden)

    Björn Karlsson

    2012-10-01

    Full Text Available One of the biggest obstacles to economic profitability of solar water heating systems is the investment cost. Retrofitting existing domestic hot water heaters when a new solar hot water system is installed can reduce both the installation and material costs. In this study, retrofitting existing water heaters for solar water heating systems in Swedish single-family houses was theoretically investigated using the TRNSYS software. Four simulation models using forced circulation flow with different system configurations and control strategies were simulated and analysed in the study. A comparison with a standard solar thermal system was also presented based on the annual solar fraction. The simulation results indicate that the retrofitting configuration achieving the highest annual performance consists of a system where the existing tank is used as storage for the solar heat and a smaller tank with a heater is added in series to make sure that the required outlet temperature can be met. An external heat exchanger is used between the collector circuit and the existing tank. For this retrofitted system an annual solar fraction of 50.5% was achieved. A conventional solar thermal system using a standard solar tank achieves a comparable performance for the same total storage volume, collector area and reference conditions.

  8. The Efficient Windows Collaborative

    Energy Technology Data Exchange (ETDEWEB)

    Petermann, Nils

    2006-03-31

    The Efficient Windows Collaborative (EWC) is a coalition of manufacturers, component suppliers, government agencies, research institutions, and others who partner to expand the market for energy efficient window products. Funded through a cooperative agreement with the U.S. Department of Energy, the EWC provides education, communication and outreach in order to transform the residential window market to 70% energy efficient products by 2005. Implementation of the EWC is managed by the Alliance to Save Energy, with support from the University of Minnesota and Lawrence Berkeley National Laboratory.

  9. Rails on Windows

    CERN Document Server

    Hibbs, Curt

    2007-01-01

    It's no secret that the entire Ruby onRails core team uses OS X as their preferreddevelopment environment. Becauseof this, it is very easy to findauthoritative information on the webabout using Rails on OS X. But the truthis that Windows developers using Railsprobably outnumber those using otherplatforms. A Windows development environmentcan be just as productive asany other platform. This is a guide to developing with Rubyon Rails under Windows. It won't teachyou how to write Ruby on Rails web applications,but it will show you what toolsto use and how to set them up to createa complete Rail

  10. Windows 8 simplified

    CERN Document Server

    McFedries, Paul

    2012-01-01

    The easiest way for visual learners to get started with Windows 8 The popular Simplified series makes visual learning easier than ever, and with more than 360,000 copies sold, previous Windows editions are among the bestselling Visual books. This guide goes straight to the point with easy-to-follow, two-page tutorials for each task. With full-color screen shots and step-by-step directions, it gets beginners up and running on the newest version of Windows right away. Learn to work with the new interface and improved Internet Explorer, manage files, share your computer, and much more. Perfect fo

  11. Windows 95 Beslutningsguide

    DEFF Research Database (Denmark)

    Sørensen, Jens Otto

    1996-01-01

    Mange virksomheder der bruger pc'er står netop nu over for valget: Skal vi fortsætte med DOS/Windows 3.x som operativsystem, eller skal vi skifte til efterfølgeren Windows 95? Skal vi/kan vi skifte successivt, eller skal det være en "alt eller intet beslutning". Hvornår er det rigtige tidspunkt...... at skifte? Denne artikel vil forsøge at give en baggrundsviden om Windows 95, der kan hjælpe virksomhederne igennem denne beslutningsfase....

  12. Windows 7 resource kit

    CERN Document Server

    Northrup, Tony; Honeycutt, Jerry; Wilson, Ed

    2009-01-01

    In-depth and comprehensive, this RESOURCE KIT delivers the information you need to administer your Windows 7 system. You get authoritative technical guidance from those who know the technology best-Microsoft Most Valuable Professionals (MVPs) and the Windows 7 product team-along with essential scripts and resources. In addition, "Direct from the Source" sidebars offer deep insights and troubleshooting tips from the Windows 7 team. Get expert guidance on how to: Use Microsoft Deployment Toolkit best practices and tools. Plan user-state migration and test application compatibility.

  13. Drivers for retrofit: a sociocultural approach to houses and inhabitants

    DEFF Research Database (Denmark)

    Tjørring, Lise; Gausset, Quentin

    2018-01-01

    , retrofits were investigated from the perspective of the everyday life of homeowners. Three social dimensions that played an important role when the people in the study discussed house renovation were identified and discussed: houses as part of homeowners’ life cycles and personal events; houses......Private households constitute approximately 30% of the total energy consumption in Denmark. The greatest potential for reducing energy consumption in private households is through retrofits of existing houses. One of the most common ways to promote retrofits is the act of sending an energy advisor...... as frameworks for social relations; and houses as markers of social values and status. These results indicate a need to develop new strategies to promote retrofits more effectively, which focus less on the techno-economic aspects and more on the social dimensions....

  14. DOE Webinar - Residential Geothermal Heat Pump Retrofits (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, E. R.

    2010-12-14

    This presentation was given December 14, 2010, as part of DOE's Webinar series. The presentation discusses geothermal heat pump retrofits, technology options, and an overview of geothermal energy and geothermal heat pumps.

  15. Transit safety retrofit package development : applications requirements document.

    Science.gov (United States)

    2014-05-01

    This Application Requirements Document for the Transit Safety Retrofit Package (TRP) Development captures the : system, hardware and software requirements towards fulfilling the technical objectives stated within the contract. : To achieve the object...

  16. LED Retrofit Kits, TLEDs, and Lighting Controls: An Application Guide

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-03-01

    This document provides guidance for retrofitting existing fluorescent troffers including the LED and associated control options available, the pro/cons and costs/benefits of each option, and agency specific requirements (where applicable).

  17. Building Performance Simulation tools for planning of energy efficiency retrofits

    DEFF Research Database (Denmark)

    Mondrup, Thomas Fænø; Karlshøj, Jan; Vestergaard, Flemming

    2014-01-01

    Designing energy efficiency retrofits for existing buildings will bring environmental, economic, social, and health benefits. However, selecting specific retrofit strategies is complex and requires careful planning. In this study, we describe a methodology for adopting Building Performance...... to energy efficiency retrofits in social housing. To generate energy savings, we focus on optimizing the building envelope. We evaluate alternative building envelope actions using procedural solar radiation and daylight simulations. In addition, we identify the digital information flow and the information...... Simulation (BPS) tools as energy and environmentally conscious decision-making aids. The methodology has been developed to screen buildings for potential improvements and to support the development of retrofit strategies. We present a case study of a Danish renovation project, implementing BPS approaches...

  18. Short-Term Test Results. Multifamily Home Energy Efficiency Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, James [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2013-01-01

    Multifamily deep energy retrofits (DERs) represent great potential for energy savings, while also providing valuable insights on research-generated efficiency measures, cost-effectiveness metrics, and risk factor strategies for the multifamily housing industry. This report describes the Bay Ridge project, a base scope retrofit with a goal of achieving 30% savings (relative to pre-retrofit), and a DER scope with a goal of 50% savings (relative to pre-retrofit). Findings from the short-term testing at Bay Ridge include air infiltration reductions of greater than 60% in the DER building; a hybrid heat pump system with a Savings to Investment Ratio (SIR) > 1 (relative to a high efficiency furnace) which also provides the resident with added incentive for energy savings; and duct leakage reductions of > 60% using an aerosolized duct sealing approach.

  19. Transit safety retrofit package development : TRP concept of operations.

    Science.gov (United States)

    2014-05-01

    This document describes the Concept of Operations (ConOps) for the Transit Safety Retrofit Package (TRP). The : ConOps describes the current state of operations with respect to the integration of Connected Vehicle technology in : transit buses, estab...

  20. Method for Determining Optimal Residential Energy Efficiency Retrofit Packages

    Energy Technology Data Exchange (ETDEWEB)

    Polly, B.; Gestwick, M.; Bianchi, M.; Anderson, R.; Horowitz, S.; Christensen, C.; Judkoff, R.

    2011-04-01

    Businesses, government agencies, consumers, policy makers, and utilities currently have limited access to occupant-, building-, and location-specific recommendations for optimal energy retrofit packages, as defined by estimated costs and energy savings. This report describes an analysis method for determining optimal residential energy efficiency retrofit packages and, as an illustrative example, applies the analysis method to a 1960s-era home in eight U.S. cities covering a range of International Energy Conservation Code (IECC) climate regions. The method uses an optimization scheme that considers average energy use (determined from building energy simulations) and equivalent annual cost to recommend optimal retrofit packages specific to the building, occupants, and location. Energy savings and incremental costs are calculated relative to a minimum upgrade reference scenario, which accounts for efficiency upgrades that would occur in the absence of a retrofit because of equipment wear-out and replacement with current minimum standards.

  1. Masonry Bearing and Shear Walls Retrofitted With Overlay Composite Material

    National Research Council Canada - National Science Library

    Al-Chaar, Ghassan

    1998-01-01

    ...) switch-house structures have been found to be vulnerable to earthquakes. One technique to reduce the seismic vulnerability of these structures is to retrofit the masonry walls using the Hexcel-Fyfe TYFO(TM) system...

  2. Windows® 7 Administrator's Pocket Consultant

    CERN Document Server

    Stanek, William

    2009-01-01

    Portable and precise, this pocket-sized guide delivers immediate answers for the day-to-day administration of Windows 7-from desktop configuration and management to networking and security issues. Zero in on core support and maintenance tasks by using quick-reference tables, instructions, and lists. You'll get the precise information you need to solve problems and get the job done-whether at your desk or in the field!

  3. Attic Retrofits Using Nail-Base Insulated Panels

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, David [Home Innovation Research Labs; Kochkin, Vladimir [Home Innovation Research Labs

    2018-03-26

    This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.

  4. Windows 10 Technical Preview

    OpenAIRE

    Jyväsjärvi, Teppo

    2015-01-01

    Tässä opinnäytetyössä tutustaan uuden kesällä 2015 virallisesti julkaistavan Windows 10 -käyttöjärjestelmän Technical Preview -kehitysversioon. Ensimmäinen Technical Preview -versio julkaistiin syksyllä 2014. Opinnäytetyössä tutustaan Windows 10:n uusin ominaisuuksiin ja tehdään vertailua aiemman Windows 8.1 -version kanssa. Työssä Windows 10 Technical Preview asennetaan virtuaalikoneelle, käydään läpi asennuksen eri vaiheet sekä suurimmat muutokset käyttöliittymässä ja sovelluksissa. Op...

  5. SAF for Windows

    DEFF Research Database (Denmark)

    Hansen, Timme

    2001-01-01

    SAF for Windows er et computerprogram til parametrisk konstruktion af translationsskaller. Skaloverfladernes tredimensionelle, facetterede form fremkommer ved en kombination af to todimensionelle formbestemmende kurver, som kan vælges og redigeres af brugeren. Programmet kan udfolde de genererede...

  6. Windows Security patch required

    CERN Multimedia

    3004-01-01

    This concerns Windows PCs (XP, 2000, NT) which are NOT centrally managed at CERN for security patches, e.g. home PCs, experiment PCs, portables,... A security hole which can give full privileges on Windows systems needs to be URGENTLY patched. Details of the security hole and hotfix are at: http://cern.ch/it-div/news/hotfix-MS03-026.asp http://www.microsoft.com/technet/security/bulletin/MS03-026.asp

  7. Delineating the conformal window

    DEFF Research Database (Denmark)

    Frandsen, Mads Toudal; Pickup, Thomas; Teper, Michael

    2011-01-01

    We identify and characterise the conformal window in gauge theories relevant for beyond the standard model building, e.g. Technicolour, using the criteria of metric confinement and causal analytic couplings, which are known to be consistent with the phase diagram of supersymmetric QCD from Seiberg...... duality. Using these criteria we find perturbation theory to be consistent throughout the predicted conformal window for several of these gauge theories and we discuss recent lattice results in the light of our findings....

  8. Windows Security patch required

    CERN Multimedia

    2003-01-01

    This concerns Windows PCs (XP, 2000, NT) which are NOT centrally managed at CERN for security patches, e.g. home PCs, experiment PCs, portables, ... A security hole which can give full privileges on Windows systems needs to be URGENTLY patched. Details of the security hole and hotfix are at: http://cern.ch/it-div/news/hotfix-MS03-026.asp http://www.microsoft.com/technet/security/bulletin/MS03-026.asp

  9. Windows Security patch required

    CERN Multimedia

    2003-01-01

    This concerns Windows PCs (XP, 2000, NT) which are NOT centrally managed at CERN for security patches, e.g. home PCs, experiment PCs, portables,... A security hole which can give full privileges on Windows systems needs to be URGENTLY patched. Details of the security hole and hotfix are at: http://cern.ch/it-div/news/hotfix-MS03-026.asp http://www.microsoft.com/technet/security/bulletin/MS03-026.asp

  10. Innovative Retrofit Insulation Strategies for Concrete Masonry Foundations

    Energy Technology Data Exchange (ETDEWEB)

    Huelman, P. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Goldberg, L. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Jacobson, R. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership

    2015-05-06

    This study was designed to test a new approach for foundation insulation retrofits, with the goal of demonstrating improved moisture control, improved occupant comfort, and reduced heat loss. Because conducting experimental research on existing below-grade assemblies is very difficult, most of the results are based on simulations. The retrofit approach consists of filling open concrete block cores with an insulating material and adding R-10 exterior insulation that extends 1 ft below grade. The core fill is designed to improve the R-value of the foundation wall and increase the interior wall surface temperature, but more importantly to block convection currents that could otherwise increase moisture loads on the foundation wall and interior space. The exterior insulation significantly reduces heat loss through the most exposed part of the foundation and further increases the interior wall surface temperature. This improves occupant comfort and decreases the risk of condensation. Such an insulation package avoids the full-depth excavation necessary for exterior insulation retrofits, reduces costs, and eliminates the moisture and indoor air quality risks associated with interior insulation retrofits. Retrofit costs for the proposed approach were estimated at roughly half those of a full-depth exterior insulation retrofit.

  11. Wyandotte Neighborhood Stabilization Program: Retrofit of Two Homes

    Energy Technology Data Exchange (ETDEWEB)

    Lukachko, A.; Grin, A.; Bergey, D.

    2013-04-01

    The Wyandotte NSP2 project aims to build 20 new houses and retrofit 20 existing houses in Wyandotte, MI. This report will detail the retrofit of 2 existing houses in the program. Wyandotte is part of a Michigan State Housing Development Authority-led consortium that is funded by HUD under the NSP2 program. The City of Wyandotte has also been awarded DOE EE&CBG funds that are being used to develop a district GSHP system to service the project. This draft report examines the energy efficiency recommendations for retrofit construction at these homes. The report will be of interest to anyone planning an affordable, high performance retrofit of an existing home in a Cold Climate zone. Information from this report will also be useful to retrofit or weatherization program staff as some of the proposed retrofit solutions will apply to a wide range of projects. Preliminary results from the first complete house suggest that the technology package employed (which includes spray foam insulation and insulating sheathing) does meet the specific whole house water, air, and thermal control requirements, as well as, the project's affordability goals. Monitoring of the GSHP system has been recommended and analysis of this information is not yet available.

  12. 48 CFR 352.239-70 - Standard for security configurations.

    Science.gov (United States)

    2010-10-01

    ... operating system patch level and anti-virus software level. Note: FDCC is applicable to all computing systems using Windows XPTM and Windows VistaTM, including desktops and laptops—regardless of function—but... applications operated on behalf of HHS are fully functional and operate correctly on systems configured in...

  13. Thin Film & Deposition Systems (Windows)

    Data.gov (United States)

    Federal Laboratory Consortium — Coating Lab: Contains chambers for growing thin film window coatings. Plasma Applications Coating Lab: Contains chambers for growing thin film window coatings. Solar...

  14. X-Windows Socket Widget Class

    Science.gov (United States)

    Barry, Matthew R.

    2006-01-01

    The X-Windows Socket Widget Class ("Class" is used here in the object-oriented-programming sense of the word) was devised to simplify the task of implementing network connections for graphical-user-interface (GUI) computer programs. UNIX Transmission Control Protocol/Internet Protocol (TCP/IP) socket programming libraries require many method calls to configure, operate, and destroy sockets. Most X Windows GUI programs use widget sets or toolkits to facilitate management of complex objects. The widget standards facilitate construction of toolkits and application programs. The X-Windows Socket Widget Class encapsulates UNIX TCP/IP socket-management tasks within the framework of an X Windows widget. Using the widget framework, X Windows GUI programs can treat one or more network socket instances in the same manner as that of other graphical widgets, making it easier to program sockets. Wrapping ISP socket programming libraries inside a widget framework enables a programmer to treat a network interface as though it were a GUI.

  15. Modeling thermal performance of exterior walls retrofitted from insulation and modified laterite based bricks materials

    Science.gov (United States)

    Wati, Elvis; Meukam, Pierre; Damfeu, Jean Claude

    2017-12-01

    Uninsulated concrete block walls commonly found in tropical region have to be retrofitted to save energy. The thickness of insulation layer used can be reduced with the help of modified laterite based bricks layer (with the considerably lower thermal conductivity than that of concrete block layer) during the retrofit building fabrics. The aim of this study is to determine the optimum location and distribution of different materials. The investigation is carried out under steady periodic conditions under the climatic conditions of Garoua in Cameroon using a Simulink model constructed from H-Tools (the library of Simulink models). Results showed that for the continuous air-conditioned space, the best wall configuration from the maximum time lag, minimum decrement factor and peak cooling transmission load perspective, is dividing the insulation layer into two layers and placing one at the exterior surface and the other layer between the two different massive layers with the modified laterite based bricks layer at the interior surface. For intermittent cooling space, the best wall configuration from the minimum energy consumption depends on total insulation thickness. For the total insulation thickness less than 8 cm approximately, the best wall configuration is placing the half layer of insulation material at the interior surface and the other half between the two different massive layers with the modified earthen material at the exterior surface. Results also showed that, the optimum insulation thickness calculated from the yearly cooling transmission (estimated only during the occupied period) and some economic considerations slightly depends on the location of that insulation.

  16. PORST: a computer code to analyze the performance of retrofitted steam turbines

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C.; Hwang, I.T.

    1980-09-01

    The computer code PORST was developed to analyze the performance of a retrofitted steam turbine that is converted from a single generating to a cogenerating unit for purposes of district heating. Two retrofit schemes are considered: one converts a condensing turbine to a backpressure unit; the other allows the crossover extraction of steam between turbine cylinders. The code can analyze the performance of a turbine operating at: (1) valve-wide-open condition before retrofit, (2) partial load before retrofit, (3) valve-wide-open after retrofit, and (4) partial load after retrofit.

  17. Pilot Residential Deep Energy Retrofits and the PNNL Lab Homes

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Chandra, Subrato; Parker, Graham B.; Sande, Susan; Blanchard, Jeremy; Stroer, Dennis; McIlvaine, Janet; Chasar, David; Beal, David; Sutherland, Karen

    2012-01-01

    This report summarizes research investigating the technical and economic feasibility of several pilot deep energy retrofits, or retrofits that save 30% to 50% or more on a whole-house basis while increasing comfort, durability, combustion safety, and indoor air quality. The work is being conducted for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. As part of the overall program, Pacific Northwest National Laboratory (PNNL) researchers are collecting and analyzing a comprehensive dataset that describes pre- and post-retrofit energy consumption, retrofit measure cost, health and comfort impacts, and other pertinent information for each home participating in the study. The research and data collection protocol includes recruitment of candidate residences, a thorough test-in audit, home energy modeling, and generation of retrofit measure recommendations, implementation of the measures, test-out, and continued evaluation. On some homes, more detailed data will be collected to disaggregate energy-consumption information. This multi-year effort began in October 2010. To date, the PNNL team has performed test-in audits on 51 homes in the marine, cold, and hot-humid climate zones, and completed 3 retrofits in Texas, 10 in Florida, and 2 in the Pacific Northwest. Two of the retrofits are anticipated to save 50% or more in energy bills and the others - savings are in the 30% to 40% range. Fourteen other retrofits are under way in the three climate zones. Metering equipment has been installed in seven of these retrofits - three in Texas, three in Florida, and one in the Pacific Northwest. This report is an interim update, providing information on the research protocol and status of the PNNL deep energy retrofit project as of December, 2011. The report also presents key findings and lessons learned, based on the body of work to date. In addition, the report summarizes the status of the PNNL Lab Homes that are new

  18. Economic Valuation of Hypothetical Paratransit Retrofitting

    Directory of Open Access Journals (Sweden)

    Naili Huda

    2015-06-01

    Full Text Available This paper describes a feasibility analysis of conventional and retrofitted paratransits, comparing economic performance of conventional paratransit with those using lead acid and lithium batteries. Research object is Dago-Kalapa paratransit in Bandung, West Java, travelling the distance of 11 km in town, under 8 peak hour operation. After calculating the estimated annual cost and benefit; net present value (NPV, payback period (PBP and internal rate of return (IRR then were quantified to provide feasibility description of those three paratransits. In addition, a sensitivity analysis regarding discount rate, gasoline price and battery price is given to offer broader sense of factors embraced. It is found that both gasoline and lead acid paratransit have big NPVs with only slight differences, while lithium paratransit has negative NPV. This phenomenon applies to their PBPs and IRRs as well. Only when gasoline costs reaches IDR 15,000 will electric paratransit prevails over conventional one. Thus, it can be inferred that at the moment, paratransit runs with gasoline is still the most cost effective compared to its counterparts. However, starting retrofitting from now is endorsed due to its environmental benefit. Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin;}

  19. Window modelling in Syrthes

    Energy Technology Data Exchange (ETDEWEB)

    Manias, V.; Peniguel, C. [Electricite de France, 78 - Chatou (France); Rupp, I. [Simulog, N3S, Estet, Simail, 78 - Saint Quentin en Yvelyne (France)

    1997-12-31

    Developments to take into account windows from a thermal point of view have been implemented in SYRTHES. Windows are discretized along their lateral surfaces in several independent patches. Then a one-dimensional analytical model solves the semi-transparent radiation and conduction problem occurring across the window for each patch. The spectral dependence of the absorption coefficient (`non grey` medium) is taken into account through a multi-band model. This window model is coupled with the conduction and radiation capabilities already existing in SYRTHES. When convection is taking place, it is handled by ESTET. This development will be applied to an infra-red system designed to dry paper. The simplified test case presented here consists very schematically in two cavities separated by a window (vitro-ceramic). The top cavity contains a very hot tungsten wire (the infrared source) surrounded by a tube made of quartz. The bottom cavity is where the fast moving sheet of paper will be located. Of Course the real geometry is much more complex. (authors)

  20. Cold Climate Foundation Retrofit Experimental Hygrothermal Performance: Cloquet Residential Research Facility Laboratory Results

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR, St. Paul, MN (United States); Harmon, Anna C. [NorthernSTAR, St. Paul, MN (United States)

    2015-04-01

    Thermal and moisture problems in existing basements create a unique challenge because the exterior face of the wall is not easily or inexpensively accessible. This approach addresses thermal and moisture management from the interior face of the wall without disturbing the exterior soil and landscaping. the interior and exterior environments. This approach has the potential for improving durability, comfort, and indoor air quality. This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes. NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.

  1. Simulation-based method to determine climatic energy strategies of an adaptable building retrofit façade system

    International Nuclear Information System (INIS)

    Capeluto, I. Guedi; Ochoa, Carlos E.

    2014-01-01

    Vast amounts of the European residential stock were built with limited consideration for energy efficiency, yet its refurbishment can help reach national energy reduction goals, decreasing environmental impact. Short-term retrofits with reduced interference to inhabitants can be achieved by upgrading facades with elements that enhance energy efficiency and user comfort. The European Union-funded Meefs Retrofitting (Multifunctional Energy Efficient Façade System) project aims to develop an adaptable mass-produced facade system for energy improvement in existing residential buildings throughout the continent. This article presents a simplified methodology to identify preferred strategies and combinations for the early design stages of such system. This was derived from studying weather characteristics of European regions and outlining climatic energy-saving strategies based on human thermal comfort. Strategies were matched with conceptual technologies like glazing, shading and insulation. The typical building stock was characterized from statistics of previous European projects. Six improvements and combinations were modelled using a simulation model, identifying and ranking preferred configurations. The methodology is summarized in a synoptic scheme identifying the energy rankings of each improvement and combination for the studied climates and façade orientations. - Highlights: • First results of EU project for new energy efficient façade retrofit system. • System consists of prefabricated elements with multiple options for flexibility. • Modular strategies were determined that adapt to different climates. • Technologies matching the strategies were identified. • Presents a method for use and application in different climates across Europe

  2. Greenbuilt Retrofit Test House Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hudon, K. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Tabares-Velasco, P. C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Barker, G. [Mountain Energy Partnership, Longmont, CO (United States); Hancock, C. E. [Mountain Energy Partnership, Longmont, CO (United States)

    2014-06-01

    The Greenbuilt house is a 1980's era house in the Sacramento area that was a prominent part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration Program. The house underwent an extensive remodel, aimed at improving overall energy efficiency with a goal of reducing the home's energy use by 50%. NREL researchers performed a number of tests on the major systems touched by the retrofit to ensure they were working as planned. Additionally, SMUD rented the house from Greenbuilt Construction for a year to allow NREL to perform a number of tests on the cooling system and the water heating system. The goal of the space conditioning tests was to find the best ways to cut cooling loads and shift the summer peak. The water heating system, comprised of an add-on heat pump water heater and an integrated collector-storage solar water heater, was operated with a number of different draw profiles to see how varying hot water draw volume and schedule affected the performance of the system as a whole. All the experiments were performed with the house empty, with a simulated occupancy schedule running in the house to mimic the load imposed by real occupants.

  3. CRNL research reactor retrofit Emergency Filtration System

    International Nuclear Information System (INIS)

    Philippi, H.M.

    1990-01-01

    This paper presents a brief history of NRX and NRU research reactor effluent air treatment systems before describing the selection and design of an appropriate retrofit Emergency Filtration System (EFS) to serve these reactors and the future MX-10 isotope production reactor. The conceptual design of the EFS began in 1984. A standby concrete shielding filter-adsorber system, sized to serve the reactor with the largest exhaust flow, was selected. The standby system, bypassed under normal operating conditions, is equipped with normal exhaust stream shutoff and diversion valves to be activated manually when an emergency is anticipated, or automatically when emergency levels of gamma radiation are detected in the exhaust stream. The first phase of the EFS installation, that is the construction of the EFS and the connection of NRU to the system, was completed in 1987. The second phase of construction, which includes the connection of NRX and provisions for the future connection of MX-10, is to be completed in 1990

  4. Occupants' window opening behaviour

    DEFF Research Database (Denmark)

    Fabi, Valentina; Andersen, Rune Korsholm; Corgnati, Stefano

    2012-01-01

    systems is proposed, based on studies presented in literature and a general process leading to the effects on energy consumptions is identified.Existing studies on the topic of window opening behaviour are highlighted and a theoretical framework to deal with occupants' interactions with building controls......, aimed at improving or maintaining the preferred indoor environmental conditions, is elaborated. This approach is used to look into the drivers for the actions taken by the occupants (windows opening and closing) and to investigate the existing models in literature of these actions for both residential...... and office buildings. The analysis of the literature highlights how a shared approach on identifying the driving forces for occupants' window opening and closing behaviour has not yet been reached. However, the reporting of variables found not to be drivers may reveal contradictions in the obtained results...

  5. Windows 8.1 bible

    CERN Document Server

    Boyce, Jim; Tidrow, Rob

    2014-01-01

    Windows 8.1 coverage that goes above and beyond all competitors? Serving as an evolutionary update to Windows 8, Windows 8.1 provides critical changes to parts of Windows 8, such as greater customization of the interface and boot operations, return of a 'start button' that reveals apps, greater integration between the two interfaces, and updates to apps. Weighing in at nearly 1000 pages, Windows 8.1 Bible provides deeper Windows insight than any other book on the market. It's valuable for both professionals needing a guide to the nooks and crannies of Windows and regular users wanting a wide

  6. Windows Deployment Services : Esiasennuspalvelin

    OpenAIRE

    Ahonen, Arto

    2010-01-01

    Opinnäytetyöni aiheena on Windows Deployment Services, jonka tarkoituksena on toimia esiasennus-palvelimena Windows-käyttöjärjestelmien levykuvien jakamiseen sekä asentamiseen. Opinnäytetyö to-teutettiin yhteistyössä Concept.10 IT:n ja tuotannon kanssa. Concept.10:n tuotannon lähtökohtana on valmistaa ja asentaa Suomen markkinoille tietokonelaitteistoja ohjelmistoineen ja tukipalveluineen. Tuo-tantoon olennaisena osana kuuluu esiasennuspalvelin, jolla voidaan asentaa useita tietokoneita samaa...

  7. Microsoft Windows networking essentials

    CERN Document Server

    Gibson, Darril

    2011-01-01

    The core concepts and technologies of Windows networking Networking can be a complex topic, especially for those new to the field of IT. This focused, full-color book takes a unique approach to teaching Windows networking to beginners by stripping down a network to its bare basics, thereby making each topic clear and easy to understand. Focusing on the new Microsoft Technology Associate (MTA) program, this book pares down to just the essentials, showing beginners how to gain a solid foundation for understanding networking concepts upon which more advanced topics and technologies can be built.

  8. Windows Azure Platform

    CERN Document Server

    Redkar, Tejaswi

    2010-01-01

    The Azure Services Platform is a brand-new cloud-computing technology from Microsoft. It is composed of four core components-Windows Azure, .NET Services, SQL Services, and Live Services-each with a unique role in the functioning of your cloud service. It is the goal of this book to show you how to use these components, both separately and together, to build flawless cloud services. At its heart Windows Azure Platform is a down-to-earth, code-centric book. This book aims to show you precisely how the components are employed and to demonstrate the techniques and best practices you need to know

  9. Microsoft Windows Security Essentials

    CERN Document Server

    Gibson, Darril

    2011-01-01

    Windows security concepts and technologies for IT beginners IT security can be a complex topic, especially for those new to the field of IT. This full-color book, with a focus on the Microsoft Technology Associate (MTA) program, offers a clear and easy-to-understand approach to Windows security risks and attacks for newcomers to the world of IT. By paring down to just the essentials, beginners gain a solid foundation of security concepts upon which more advanced topics and technologies can be built. This straightforward guide begins each chapter by laying out a list of topics to be discussed,

  10. Design and development of split-parallel through-the road retrofit hybrid electric vehicle with in-wheel motors

    Science.gov (United States)

    Zulkifli, S. A.; Syaifuddin Mohd, M.; Maharun, M.; Bakar, N. S. A.; Idris, S.; Samsudin, S. H.; Firmansyah; Adz, J. J.; Misbahulmunir, M.; Abidin, E. Z. Z.; Syafiq Mohd, M.; Saad, N.; Aziz, A. R. A.

    2015-12-01

    One configuration of the hybrid electric vehicle (HEV) is the split-axle parallel hybrid, in which an internal combustion engine (ICE) and an electric motor provide propulsion power to different axles. A particular sub-type of the split-parallel hybrid does not have the electric motor installed on board the vehicle; instead, two electric motors are placed in the hubs of the non-driven wheels, called ‘hub motor’ or ‘in-wheel motor’ (IWM). Since propulsion power from the ICE and IWM is coupled through the vehicle itself, its wheels and the road on which it moves, this particular configuration is termed ‘through-the-road’ (TTR) hybrid. TTR configuration enables existing ICE-powered vehicles to be retrofitted into an HEV with minimal physical modification. This work describes design of a retrofit- conversion TTR-IWM hybrid vehicle - its sub-systems and development work. Operating modes and power flow of the TTR hybrid, its torque coupling and resultant traction profiles are initially discussed.

  11. Assessment and evaluation of timber piles used in Nebraska for retrofit and rating.

    Science.gov (United States)

    2014-04-01

    The cost of an effective retrofitting and rehabilitation of timber piles is less than cost of replacing the piles. However, some of the retrofit options used in Nebraska failed to result in the expected performance levels. Further, design and detaili...

  12. 77 FR 24505 - Hazard Mitigation Assistance for Wind Retrofit Projects for Existing Residential Buildings

    Science.gov (United States)

    2012-04-24

    ...] Hazard Mitigation Assistance for Wind Retrofit Projects for Existing Residential Buildings AGENCY... for Wind Retrofit Projects for Existing Residential Buildings. DATES: Comments must be received by... to protect existing one- and two-family residential buildings (not including manufactured housing...

  13. Retrofitting of Reinforced Concrete Beams using Reactive Powder Concrete (RPC)

    Science.gov (United States)

    Karthik, S.; Sundaravadivelu, Karthik

    2017-07-01

    Strengthening of existing damaged structures is one of the leading studies in civil engineering. The purpose of retrofitting is to structurally treat the member with an aim to restore the structure to its original strength. The focus of this project is to study the behaviour of damaged Reinforced Concrete beam retrofitted with Reactive Powder Concrete (RPC) Overlay. Reinforced concrete beams of length 1200 mm, width 100 mm and depth 200 mm were casted with M30 grade of concrete in the laboratory and cured for 28 days. One beam is taken as control and are tested under two point loading to find out ultimate load. Remaining beams are subjected to 90 % ultimate load of control beams. The partially damaged beams are retrofitted with Reactive Powder Concrete Overlay at the full tension face of the beam and side overlay depends upon the respectable retrofitting techniques with 10 mm and 20 mm thick layer to find optimum. Materials like steel fibres are added to enhance the ductility by eliminating coarse particle for homogeneity of the structure. Finally, the modes of failure for retrofitted beams are analysed experimentally under two point loading & compared the results with Control beam.

  14. Short-Term Test Results: Multifamily Home Energy Efficiency Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, J.

    2013-01-01

    Multifamily deep energy retrofits (DERs) represent great potential for energy savings, while also providing valuable insights on research-generated efficiency measures, cost-effectiveness metrics, and risk factor strategies for the multifamily housing industry. The Bay Ridge project is comprised of a base scope retrofit with a goal of achieving 30% savings (relative to pre-retrofit), and a DER scope with a goal of 50% savings (relative to pre-retrofit). The base scope has been applied to the entire complex, except for one 12-unit building which underwent the DER scope. Findings from the implementation, commissioning, and short-term testing at Bay Ridge include air infiltration reductions of greater than 60% in the DER building; a hybrid heat pump system with a Savings to Investment Ratio (SIR) > 1 (relative to a high efficiency furnace) which also provides the resident with added incentive for energy savings; and duct leakage reductions of > 60% using an aerosolized duct sealing approach. Despite being a moderate rehab instead of a gut rehab, the Bay Ridge DER is currently projected to achieve energy savings ≥ 50% compared to pre-retrofit, and the short-term testing supports this estimate.

  15. Wyandotte Neighborhood Stabilization Program: Retrofit of Two Homes

    Energy Technology Data Exchange (ETDEWEB)

    Lukachko, A. [Building Science Corporation (BSC), Somerville, MA (United States); Grin, A. [Building Science Corporation (BSC), Somerville, MA (United States); Bergey, D. [Building Science Corporation (BSC), Somerville, MA (United States)

    2013-04-01

    The Wyandotte NSP2 project aims to build 20 new houses and retrofit 20 existing houses in Wyandotte, MI. Wyandotte is part of a Michigan State Housing Development Authority-led consortium that is funded by HUD under the NSP2 program. The City of Wyandotte has also been awarded DOE EE&CBG funds that are being used to develop a district ground source heat pump (GSHP) system to service the project. This report details the retrofit of two existing houses in the program, and examines the energy efficiency recommendations for the homes. The report will be of interest to anyone planning an affordable, high performance retrofit of an existing home in a cold climate zone. Information from this report will also be useful to retrofit or weatherization program staff as some of the proposed retrofit solutions will apply to a wide range of projects. Preliminary results from the first complete house suggest that the technology package employed (which includes spray foam insulation and insulating sheathing) does meet the specific whole house water, air, and thermal control requirements, as well as, the project’s affordability goals. Monitoring of the GSHP system has been recommended and analysis of this information is not yet available.

  16. Windows® Small Business Server 2008 Administrator's Pocket Consultant

    CERN Document Server

    Zacker, Craig

    2009-01-01

    Portable and precise, this pocket-sized guide delivers ready answers for administering Windows Small Business Server 2008. Zero in on core support tasks and tools using quick-reference tables, instructions, and lists. You'll get the focused information you need to solve problems and get the job done-whether at your desk or in the field. Get fast facts to: Plan, install, and configure a small business network Navigate the Windows SBS Console toolCreate and administer user and group accounts Manage automatic updates, disk storage, and shared printersConfigure mail settings and customize inte

  17. "Stained Glass" Landscape Windows

    Science.gov (United States)

    Vannata, Janine

    2008-01-01

    Both adults and children alike marvel at the grand vivid stained-glass windows created by American artist Louis Comfort Tiffany. Today he is commonly recognized as one of America's most influential designers and artists throughout the last nineteenth and early twentieth century. In the lesson described in this article, students created their own…

  18. Exploring Shop Window Displays

    Science.gov (United States)

    Christopoulou, Martha

    2011-01-01

    Using visual resources from everyday life in art lessons can enrich students' knowledge about the creation of visual images, artifacts, and sites, and develop their critical understanding about the cultural impact of these images and their effects on people's lives. Through examining an exhibition in the windows of Selfridges department store in…

  19. Opening the Literature Window

    Science.gov (United States)

    Jago, Carol

    2012-01-01

    Great literature gives students a window to other places and times, but it often requires students to step outside their comfort zones and take on challenges they wouldn't usually attempt. Unfortunately, research shows that many schools are not assigning literature that pushes students beyond their current reading level. Jago encourages teachers…

  20. Simple cryogenic infrared window

    NARCIS (Netherlands)

    Hartemink, M.; Hartemink, M.; Godfried, H.P; Godfried, Herman

    1991-01-01

    A simple, cheap technique is reported that allows materials with both large and small thermal expansion coefficients to be mounted as windows in low temperature cryostats while at the same time avoiding thermal stresses. The construction may be thermally cycled many times with no change in its

  1. Regularity of Dual Gabor Windows

    Directory of Open Access Journals (Sweden)

    Ole Christensen

    2013-01-01

    Full Text Available We present a construction of dual windows associated with Gabor frames with compactly supported windows. The size of the support of the dual windows is comparable to that of the given window. Under certain conditions, we prove that there exist dual windows with higher regularity than the canonical dual window. On the other hand, there are cases where no differentiable dual window exists, even in the overcomplete case. As a special case of our results, we show that there exists a common smooth dual window for an interesting class of Gabor frames. In particular, for any value of K∈ℕ, there is a smooth function h which simultaneously is a dual window for all B-spline generated Gabor frames {EmbTnBN(x/2}m,n∈ℕ for B-splines BN of order N=1,…,2K+1 with a fixed and sufficiently small value of b.

  2. Measure Guideline: Three High Performance Mineral Fiber Insulation Board Retrofit Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Neuhauser, Ken [Building Science Corporation, Westford, MA (United States)

    2015-01-01

    This Measure Guideline describes a high performance enclosure retrofit package that uses mineral fiber insulation board. The Measure Guideline describes retrofit assembly and details for wood frame roof and walls and for cast concrete foundations. This Measure Guideline is intended to serve contractors and designers seeking guidance for non-foam exterior insulation retrofit.

  3. Measure Guideline: Three High Performance Mineral Fiber Insulation Board Retrofit Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Neuhauser, K. [Building Science Corporation, Westford, MA (United States)

    2015-01-01

    This Measure Guideline describes a high performance enclosure retrofit package that uses mineral fiber insulation board, and is intended to serve contractors and designers seeking guidance for non-foam exterior insulation retrofit processes. The guideline describes retrofit assembly and details for wood frame roof and walls and for cast concrete foundations.

  4. Field Assessment of Energy Audit Tools for Retrofit Programs

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, J. [Univ. of Minnesota, St. Paul, MN (United States); Bohac, D. [Univ. of Minnesota, St. Paul, MN (United States); Nelson, C. [Univ. of Minnesota, St. Paul, MN (United States); Smith, I. [Univ. of Minnesota, St. Paul, MN (United States)

    2013-07-01

    This project focused on the use of home energy ratings as a tool to promote energy retrofits in existing homes. A home energy rating provides a quantitative appraisal of a home’s energy performance, usually compared to a benchmark such as the average energy use of similar homes in the same region. Rating systems based on energy performance models, the focus of this report, can establish a home’s achievable energy efficiency potential and provide a quantitative assessment of energy savings after retrofits are completed, although their accuracy needs to be verified by actual measurement or billing data. Ratings can also show homeowners where they stand compared to their neighbors, thus creating social pressure to conform to or surpass others. This project field-tested three different building performance models of varying complexity, in order to assess their value as rating systems in the context of a residential retrofit program: Home Energy Score, SIMPLE, and REM/Rate.

  5. Industrial-scale study of a retrofitted electrostatic precipitator

    Energy Technology Data Exchange (ETDEWEB)

    Jedrusik, M.; Jedrusik, J.; Sarna, M. [Technical University of Wroclaw, Wroclaw (Poland). Inst. of Heat Engineering and Fluid Mechanics

    1998-07-01

    Investigated was a retrofitted horizontal, three-zone electrostatic precipitator, which was designed in the late 1970s. The precipitator was installed after a bituminous-coal-fired 140 MW boiler. Prior to retrofit, the precipitator had spiked band corona electrodes which were to provide a firm efficiency of 95%. To make it comply with the enforced environmental standards it was necessary to increase this value. The retrofit consisted of replacing the spiked band corona electrode with a barbed-tube unit of a special design, which raised the efficiency of the precipitator to 99%, thus providing a dust concentration of 75 mg/m{sup 3} in the flue gas. These values were achieved without introducing additional zones. Prior to dust concentration measurements, the distribution of gas velocity at the inlet of an industrial precipitator was determined. The efficiency of the precipitator was measured for various heating power of the boiler to illustrate the improvement obtained. 6 refs., 3 figs., 2 tabs.

  6. Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J.; Podorson, D.; Varshney, K.

    2014-05-01

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

  7. IMPROVEMENT TO PIPELINE COMPRESSOR ENGINE RELIABILITY THROUGH RETROFIT MICRO-PILOT IGNITION SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Scott Chase; Daniel Olsen; Ted Bestor

    2005-05-01

    the field demonstration phase in Year 3. In all, there were twelve (12) tasks defined and executed to support objectives in a stepwise fashion. The optimized four-cylinder system data demonstrated significant progress compared to Phase I results, as well as traditional spark ignition systems. These laboratory results were enhanced, then verified via a field demonstration project during Phase III of the Micropilot Ignition program. An Implementation Team of qualified engine retrofit service providers was assembled to install the retrofit micropilot ignition system on an engine operated by El Paso Pipeline Group at a compressor station near Window Rock, Arizona. Testing of this demonstration unit showed that the same benefits identified by laboratory testing at CSU, i.e., reduced fuel consumption and exhaust emissions (NOx, THC, CO, and CH2O). Commercialization of the retrofit micropilot ignition technology is awaiting a ''market pull'', which is expected to materialize as the results of the field demonstration become known and accepted. The Implementation Team, comprised of Woodward Governor Company, Enginuity LLC, Hoerbiger Corporation of America, and DigiCon Inc., has direct experience with the technology development and implementation, and stands ready to promote and commercialize the retrofit micropilot ignition system.

  8. Field Evaluation of Highly Insulating Windows in the Lab Homes: Winter Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Graham B.; Widder, Sarah H.; Bauman, Nathan N.

    2012-06-01

    This field evaluation of highly insulating windows was undertaken in a matched pair of 'Lab Homes' located on the Pacific Northwest National Laboratory (PNNL) campus during the 2012 winter heating season. Improving the insulation and solar heat gain characteristics of a home's windows has the potential to significantly improve the home's building envelope and overall thermal performance by reducing heat loss (in the winter), and cooling loss and solar heat gain (in the summer) through the windows. A high quality installation and/or window retrofit will also minimize or reduce air leakage through the window cavity and thus also contribute to reduced heat loss in the winter and cooling loss in the summer. These improvements all contribute to decreasing overall annual home energy use. Occupant comfort (non-quantifiable) can also be increased by minimizing or eliminating the cold 'draft' (temperature) many residents experience at or near window surfaces that are at a noticeably lower temperature than the room air temperature. Lastly, although not measured in this experiment, highly insulating windows (triple-pane in this experiment) also have the potential to significantly reduce the noise transmittance through windows compared to standard double-pane windows. The metered data taken in the Lab Homes and data analysis presented here represent 70 days of data taken during the 2012 heating season. As such, the savings from highly insulating windows in the experimental home (Lab Home B) compared to the standard double-pane clear glass windows in the baseline home (Lab Home A) are only a portion of the energy savings expected from a year-long experiment that would include a cooling season. The cooling season experiment will take place in the homes in the summer of 2012, and results of that experiment will be reported in a subsequent report available to all stakeholders.

  9. Increasing draft capability for retrofit flue gas desulfurization systems

    International Nuclear Information System (INIS)

    Petersen, R.D.; Basel, B.E.; Mosier, R.J.

    1992-01-01

    The retrofit installation of flue gas desulfurization (FGD) systems results in significantly higher draft losses for existing generating stations. Consequently, the means for increasing draft capability must be included in many FGD retrofit projects. Consideration is given to several alternatives for increasing draft capability. Alternatives are developed for new induced draft (ID) fans to replace the existing ID fans and for new booster fans to supplement the existing ID fans. Both centrifugal and axial fans are evaluated, as are different means of fan volume control. Each alternative is evaluated on the basis of technical merit and economics. Presented are the development of fan alternatives and results of the technical and economic evaluations

  10. Method to evaluate window products with respect to a specific application

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe; Svendsen, Sv Aa Højgaard

    1997-01-01

    A two-node model of a room has been implemented in a computer program, WinSim, de-veloped for evaluation of thermal window performance in new buildings and in case of ret-rofitting. The program calculates the annual heating demand and the number of hours with indoor temperatures higher than a user...... building simulation program. Good agreement has been found between the two programs with respect to cal-culated annual heating demand and energy savings due to window exchange, and also the calculated indoor thermal comfort level is in the same range. Based on the limited examples used for the comparison...... it can be concluded that WinSim is well suited for a fast and realis-tic evaluation of thermal window performance....

  11. Daylight Redirecting Window Films

    Science.gov (United States)

    2013-09-01

    The open office area (Figure 9) is 48’ deep with a sloped ceiling designed to disperse light down into the cubicle workstations. The sloped ceiling...Ceiling Ht. 9’ , 10’* Window VT 40%, 70%* Office Furniture 60” Cubicle * Lighting Schedule ASHRAE 90.1* Blinds Control Always Closed, Automated...2829 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) ESTCP Program Office Dr. James

  12. Software configuration management

    International Nuclear Information System (INIS)

    Arribas Peces, E.; Martin Faraldo, P.

    1993-01-01

    Software Configuration Management is directed towards identifying system configuration at specific points of its life cycle, so as to control changes to the configuration and to maintain the integrity and traceability of the configuration throughout its life. SCM functions and tasks are presented in the paper

  13. Windows with improved energy performances

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    2003-01-01

    Heat loss through windows represents a considerable part of the total heat loss from houses. However, apart from providing daylight access and view, windows offer a unique potential for solar gain to be exploited during the heating season. Until now valuation of the energy performance of windows...... has primary focused on the heat loss coefficient, U-value. However, as the U-value, especially for the glazing part, has improved considerably during the last years, the total solar energy transmittance, g-value, has become equally important to the total energy performance of windows. Improved energy...... performance of windows can be reached by development of each element of the window, but to gain a considerable improvement in the overall energy performance all elements of the windows need to be examined together and the construction optimised. This paper describes potential improvements of window elements...

  14. Evaluation of CNT Energy Savers Retrofit Packages Implemented in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Farley, Jenne [Partnership for Advanced Residential Retrofit (PARR), Chicago, IL (United States); Ruch, Russell [Partnership for Advanced Residential Retrofit (PARR), Chicago, IL (United States)

    2013-09-01

    This evaluation explored the feasibility of designing prescriptive retrofit measure packages for typical Chicago region multifamily buildings in order to achieve 25%-30% source energy savings through the study of three case studies. There is an urgent need to scale up energy efficiency retrofitting of Chicago's multifamily buildings in order to address rising energy costs and a rapidly depletingrental stock. Aimed at retrofit program administrators and building science professionals, this research project investigates the possibility of using prescriptive retrofit packages as a time- and resource-effective approach to the process of retrofitting multifamily buildings.

  15. Evaluation of CNT Energy Savers Retrofit Packages Implemented in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Farley, Jenne [Partnership for Advanced Residential Retrofit (PARR), Chicago, IL (United States); Ruch, Russell [Partnership for Advanced Residential Retrofit (PARR), Chicago, IL (United States)

    2013-09-01

    This evaluation explored the feasibility of designing prescriptive retrofit measure packages for typical Chicago region multifamily buildings in order to achieve 25%-30% source energy savings through the study of three case studies. There is an urgent need to scale up energy efficiency retrofitting of Chicago's multifamily buildings in order to address rising energy costs and a rapidly depleting rental stock. Aimed at retrofit program administrators and building science professionals, this research project investigates the possibility of using prescriptive retrofit packages as a time- and resource-effective approach to the process of retrofitting multifamily buildings.

  16. Understanding and Supporting Window Switching

    NARCIS (Netherlands)

    Tak, S.

    2011-01-01

    Switching between windows on a computer is a frequent activity, but finding and switching to the target window can be inefficient. This thesis aims to better un-derstand and support window switching. It explores two issues: (1) the lack of knowledge of how people currently interact with and switch

  17. A Window-Washing Challenge

    Science.gov (United States)

    Roman, Harry T.

    2010-01-01

    Skyscrapers sure do have a lot of windows, and these windows are cleaned and checked regularly. All this takes time, money, and puts workers at potential risk. Might there be a better way to do it? In this article, the author discusses a window-washing challenge and describes how students can tackle this task, pick up the challenge, and creatively…

  18. Public participation in energy saving retrofitting of residential buildings in China

    International Nuclear Information System (INIS)

    Liu, Wenling; Zhang, Jinyun; Bluemling, Bettina; Mol, Arthur P.J.; Wang, Can

    2015-01-01

    Highlights: • We compare public participation in three early cases of residential retrofitting in Beijing. • Residents’ involvement in pre-retrofit activities as well as in the choice and use of technologies varied. • More involvement of residents during retrofitting improves energy saving performance. • Taking into account motives and energy use practices of residents improves energy saving through retrofitting. - Abstract: Retrofitting existing residential buildings has been claimed as one crucial way to reduce energy consumption and greenhouse gas emissions within the Chinese residential sector. In China’s government-dominated retrofitting projects, the participation of residents is often neglected. The objective of this paper is to assess the influence level of public participation (before, during and after retrofit) on energy saving by comparing three Beijing neighborhoods with different retrofitting models: a central government-led model, a local government-led model, and an old neighborhood retrofit model. In the three cases data were collected through interviews with neighborhood workers and residents. The results show that residents’ involvement in pre-retrofit activities, in technology selection and in the use of technology differs greatly among the three cases. This study concludes that in order to improve the effectiveness of energy saving interventions, the motives, intentions and living habits of residents need to be given more consideration when designing and implementing retrofitting. By highlighting the importance of public participation this paper contributes to energy saving policy development in China

  19. Dowel Bar Retrofit Mix Design and Specification : Technical Report

    Science.gov (United States)

    2012-01-01

    Current INDOT specifications for repair materials to be used in dowel bar retrofit (DBR) applications (Sections 507.08 and 901.07 of INDOTs Book of Specifications) are based, in large part, on the requirements of ASTM C 928 and the manufacturer-pr...

  20. Indoor Environmental Quality Benefits of Apartment Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Adamkiewicz, Gary [Harvard School of Public Health, Boston MA (United States); Delp, William W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Russell, Marion [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spears, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vermeer, Kimberly [Urban Habitate Initiatives Inc., Boston, MA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-06-01

    Sixteen apartments serving low-income populations in three buildings were retrofit with the goal of simultaneously reducing energy consumption and improving indoor environmental quality (IEQ). Retrofit measures varied among apartments and included, among others, envelope sealing, installation of continuous mechanical ventilation systems, upgrading bathroom fans and range hoods, attic insulation, replacement of heating and cooling systems, and adding wall-mounted particle air cleaners. IEQ parameters were measured, generally for two one-week periods before and after the retrofits. The measurements indicate an overall improvement in IEQ conditions after the retrofits. Comfort conditions, bathroom humidity, and concentrations of carbon dioxide, acetaldehyde, volatile organic compounds, and particles generally improved. Formaldehyde and nitrogen dioxide levels decreased in the building with the highest concentrations, were unchanged in a second building, and increased in a third building. IEQ parameters other than particles improved more in apartments with continuous mechanical ventilation systems installed. In general, but not consistently, larger percent increases in air exchange rates were associated with larger percent decreases in indoor levels of the pollutants that primarily come from indoor sources.

  1. The application, benefits and challenges of retrofitting the existing buildings

    Science.gov (United States)

    Khairi, Muhammad; Jaapar, Aini; Yahya, Zaharah

    2017-11-01

    Sustainable development has been the main topic of debate for years in some countries such as United Kingdom, United State of America and Malaysia. Depletion of natural resources, global warming, economics uncertainty and health issues are some of the reasons behind sustainable development movements, it is not just a political debate in the parliament but more towards collective works among sectors in order to minimizing the negative impact of development to the environment and other living organism. Retrofit an existing building is one of the solutions to reduce the dependency on constructing new buildings. There are huge numbers of existing building stocks that suitable to be retrofitted such as historical buildings, offices, residential, warehouse, factories, vacant buildings and other historical buildings. Therefore, the aim of this research is to provide information on the application, benefits and challenges of retrofitting an existing building. Two buildings were chosen as case studies following by site visits and observation to the buildings. The data were then compared in a table form. Primary and secondary sources were also used for this research. The application of retrofit should be promoted across the construction and conservation industries since it has significant tangible and intangible benefits. It is one of the most environmentally friendly and efficient solutions to optimize the energy performance and could also helps to extend the life of the existing building or historical buildings while ensuring optimum thermal comfort for the occupants which leads to higher productivity.

  2. Optimal Retrofit Scheme for Highway Network under Seismic Hazards

    Directory of Open Access Journals (Sweden)

    Yongxi Huang

    2014-06-01

    Full Text Available Many older highway bridges in the United States (US are inadequate for seismic loads and could be severely damaged or collapsed in a relatively small earthquake. According to the most recent American Society of Civil Engineers’ infrastructure report card, one-third of the bridges in the US are rated as structurally deficient and many of these structurally deficient bridges are located in seismic zones. To improve this situation, at-risk bridges must be identified and evaluated and effective retrofitting programs should be in place to reduce their seismic vulnerabilities. In this study, a new retrofit strategy decision scheme for highway bridges under seismic hazards is developed and seamlessly integrate the scenario-based seismic analysis of bridges and the traffic network into the proposed optimization modeling framework. A full spectrum of bridge retrofit strategies is considered based on explicit structural assessment for each seismic damage state. As an empirical case study, the proposed retrofit strategy decision scheme is utilized to evaluate the bridge network in one of the active seismic zones in the US, Charleston, South Carolina. The developed modeling framework, on average, will help increase network throughput traffic capacity by 45% with a cost increase of only $15million for the Mw 5.5 event and increase the capacity fourfold with a cost of only $32m for the Mw 7.0 event.

  3. A structured approach to heat exchanger network retrofit design

    NARCIS (Netherlands)

    Van Reisen, J.L.B.

    2008-01-01

    Process plants have high energy consumption. Much energy can be saved by a proper design of the heat exchanger network, which contains the main heat transferring equipment of the plant. Existing plants can often be made more energy-efficient by a retrofit: the (physical) modification of the

  4. Closed cycle MHD power plant and retrofit optimization application

    Science.gov (United States)

    Cutting, J. C.; Owens, W. R.; Sheth, P. R.; Griswold, J.; Wehrey, M.

    1980-06-01

    The results of two independent studies of closed-cycle MHD power systems are presented. A combined cycle consisting of an MHD closed-cycle topping unit retrofitted to an existing steam bottoming plant is considered. Preliminary results of an ongoing parametric study of an MHD closed-cycle system utilizing an integrated pressurized coal gasifier are discussed.

  5. Public Housing: A Tailored Approach to Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Conlin, F. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Podorson, D. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Alaigh, K. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Davis, T. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2016-02-23

    The Building America research team Advanced Residential Integrated Energy Solutions Collaborative (ARIES) worked with four public housing authorities (PHAs) to develop packages of energy-efficiency retrofit measures that the PHAs can cost-effectively implement with their own staffs during the normal course of housing operations when units are refurbished between occupancies.

  6. Whole Foods Market Retrofits Multiple Building Systems for Big Savings

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-03-01

    Whole Foods Market partnered with U.S. the Department of Energy (DOE) to develop and implement solutions to reduce annual energy consumption in existing stores by at least 30% versus pre-retrofit energy use at its store in Edgewater, New Jersey, as part of DOE’s Commercial Building Partnership (CBP) program.

  7. Feasibility of Retrofitting Lifts on Commuter and Light Rail Vehicles

    Science.gov (United States)

    1980-09-01

    The objectives of this study were to determine if lift retrofit applications to rail vehicles are technically feasible, and if so, the extent to which existing bus lift technology can be utilized. This report examines some of the technical issues ass...

  8. High power solid state retrofit lamp thermal characterization and modeling

    NARCIS (Netherlands)

    Jakovenko, J.; Formánek, J.; Vladimír, J.; Husák, M.; Werkhoven, R.J.

    2012-01-01

    Thermal and thermo-mechanical modeling and characterization of solid state lightening (SSL) retrofit LED Lamp are presented in this paper. Paramount Importance is to design SSL lamps for reliability, in which thermal and thermo-mechanical aspects are key points. The main goal is to get a precise 3D

  9. Teach yourself visually Windows 10

    CERN Document Server

    McFedries, Paul

    2015-01-01

    Learn Windows 10 visually with step-by-step instructions Teach Yourself VISUALLY Windows 10 is the visual learner's guide to the latest Windows upgrade. Completely updated to cover all the latest features, this book walks you step-by-step through over 150 essential Windows tasks. Using full color screen shots and clear instruction, you'll learn your way around the interface, set up user accounts, play media files, download photos from your camera, go online, set up email, and much more. You'll even learn how to customize Windows 10 to suit the way you work best, troubleshoot and repair common

  10. Multi-criteria decision model for retrofitting existing buildings

    Directory of Open Access Journals (Sweden)

    M. D. Bostenaru Dan

    2004-01-01

    Full Text Available Decision is an element in the risk management process. In this paper the way how science can help in decision making and implementation for retrofitting buildings in earthquake prone urban areas is investigated. In such interventions actors from various spheres are involved. Their interests range among minimising the intervention for maximal preservation or increasing it for seismic safety. Research was conducted to see how to facilitate collaboration between these actors. A particular attention was given to the role of time in actors' preferences. For this reason, on decision level, both the processural and the personal dimension of risk management, the later seen as a task, were considered. A systematic approach was employed to determine the functional structure of a participative decision model. Three layers on which actors implied in this multi-criteria decision problem interact were identified: town, building and element. So-called 'retrofit elements' are characteristic bearers in the architectural survey, engineering simulations, costs estimation and define the realms perceived by the inhabitants. This way they represent an interaction basis for the interest groups considered in a deeper study. Such orientation means for actors' interaction were designed on other levels of intervention as well. Finally, an 'experiment' for the implementation of the decision model is presented: a strategic plan for an urban intervention towards reduction of earthquake hazard impact through retrofitting. A systematic approach proves thus to be a very good communication basis among the participants in the seismic risk management process. Nevertheless, it can only be applied in later phases (decision, implementation, control only, since it serves verifying and improving solution and not developing the concept. The 'retrofit elements' are a typical example of the detailing degree reached in the retrofit design plans in these phases.

  11. Windows Azure web sites

    CERN Document Server

    Chambers, James

    2013-01-01

    A no-nonsense guide to maintaining websites in Windows Azure If you're looking for a straightforward, practical guide to get Azure websites up and running, then this is the book for you. This to-the-point guide provides you with the tools you need to move and maintain a website in the cloud. You'll discover the features that most affect developers and learn how they can be leveraged to work to your advantage. Accompanying projects enhance your learning experience and help you to walk away with a thorough understanding of Azure's supported technologies, site deployment, and manageme

  12. Windows Terminal Servers Orchestration

    Science.gov (United States)

    Bukowiec, Sebastian; Gaspar, Ricardo; Smith, Tim

    2017-10-01

    Windows Terminal Servers provide application gateways for various parts of the CERN accelerator complex, used by hundreds of CERN users every day. The combination of new tools such as Puppet, HAProxy and Microsoft System Center suite enable automation of provisioning workflows to provide a terminal server infrastructure that can scale up and down in an automated manner. The orchestration does not only reduce the time and effort necessary to deploy new instances, but also facilitates operations such as patching, analysis and recreation of compromised nodes as well as catering for workload peaks.

  13. Transparent aerogel Windows

    DEFF Research Database (Denmark)

    Jensen, Karsten Ingerslev; Schultz, Jørgen Munthe

    In a recent EU FP5 project, monolithic silica aerogel was further developed with respect to the production process at pilot-scale, its properties and the application as transparent insulation material in highly insulating and transparent windows. The aerogel production process has been optimised......-value of 0.7 W/m²K for about 14 mm aerogel thickness, which for a 20 mm thickness corresponds to a U-value of approximately 0.5 W/m²K. No other known glazing exhibits such an excellent combination of solar transmittance and heat loss coefficient. At a Danish location and North facing, the energy balance...

  14. Windows on animal minds.

    Science.gov (United States)

    Griffin, D R

    1995-06-01

    The simple kinds of conscious thinking that probably occur in nonhuman animals can be studied objectively by utilizing the same basic procedure that we use every day to infer what our human companions think and feel. This is to base such inferences on communicative behavior, broadly defined to include human language, nonverbal communication, and semantic communication in apes, dolphins, parrots, and honeybees. It seems likely that animals often experience something similar to the messages they communicate. Although this figurative window on other minds is obviously imperfect, it is already contributing significantly to our growing understanding and appreciation of animal mentality.

  15. Invariant sets for Windows

    CERN Document Server

    Morozov, Albert D; Dragunov, Timothy N; Malysheva, Olga V

    1999-01-01

    This book deals with the visualization and exploration of invariant sets (fractals, strange attractors, resonance structures, patterns etc.) for various kinds of nonlinear dynamical systems. The authors have created a special Windows 95 application called WInSet, which allows one to visualize the invariant sets. A WInSet installation disk is enclosed with the book.The book consists of two parts. Part I contains a description of WInSet and a list of the built-in invariant sets which can be plotted using the program. This part is intended for a wide audience with interests ranging from dynamical

  16. Windows Azure Platform

    CERN Document Server

    Redkar, Tejaswi

    2011-01-01

    The Windows Azure Platform has rapidly established itself as one of the most sophisticated cloud computing platforms available. With Microsoft working to continually update their product and keep it at the cutting edge, the future looks bright - if you have the skills to harness it. In particular, new features such as remote desktop access, dynamic content caching and secure content delivery using SSL make the latest version of Azure a more powerful solution than ever before. It's widely agreed that cloud computing has produced a paradigm shift in traditional architectural concepts by providin

  17. Windows on the axion

    International Nuclear Information System (INIS)

    Turner, M.S.

    1989-04-01

    Peccei-Quinn symmetry with attendant axion is a most compelling, and perhaps the most minimal, extension of the standard model, as it provides a very elegant solution to the nagging strong CP-problem associated with the Θ vacuum structure of QCD. However, particle physics gives little guidance as to the axion mass; a priori, the plausible values span the range: 10/sup /minus/12/ eV /approx lt/ m/sub a/ /approx lt/ 10 6 eV, some 18 orders-of-magnitude. Axions have a host of interesting astrophysical and cosmological effects, including, modifying the evolution of stars of all types (our sun, red giants, white dwarfs, and neutron stars), contributing significantly to the mass density of the Universe today, and producing detectable line radiation through the decays of relic axions. Consideration of these effects has probed 14 orders-of-magnitude in axion mass, and has left open only two windows for further exploration: 10/sup /minus/6/ eV /approx lt/ m/sub a/ /approx lt/ 10/sup /minus/3/ eV and 1 eV /approx lt/ m/sub a/ /approx lt/ 5 eV (hadronic axions only). Both these windows are accessible to experiment, and a variety of very interesting experiments, all of which involve ''heavenly axions,'' are being planned or are underway. 58 refs., 6 figs., 1 tab

  18. WINDOW-CLEANING

    CERN Multimedia

    Environmental Section / ST-TFM

    2001-01-01

    The two-month window-cleaning session on the Meyrin, Prévessin and LEP sites will soon begin. The cleaning contractors will work from Monday to Saturday, every week from 4.00 a.m. to 8.00 p.m. The work will be organised so as to disturb users as little as possible. In any event, a work notice will be left in each office 24 hours beforehand. To prevent any damage to documents or items which could occur despite the precautions taken, please clear completely the window-sills and the area immediately around them. If, however, for valid reasons, the work cannot be done on the scheduled day, please inform the Environmental Section by telephoning: 73753 / 74233 / 72242 If you are going to be absent during this two-month period, we should be grateful if you would clear the above mentioned areas before your departure. REMINDER To allow more thorough cleaning of the entrance doors to buildings and also facilitate the weekly work of the cleaning contractors, we ask you to make use of the notice boards at the...

  19. Windows on the axion

    Energy Technology Data Exchange (ETDEWEB)

    Turner, M.S.

    1989-04-01

    Peccei-Quinn symmetry with attendant axion is a most compelling, and perhaps the most minimal, extension of the standard model, as it provides a very elegant solution to the nagging strong CP-problem associated with the THETA vacuum structure of QCD. However, particle physics gives little guidance as to the axion mass; a priori, the plausible values span the range: 10/sup /minus/12/ eV /approx lt/ m/sub a/ /approx lt/ 10/sup 6/ eV, some 18 orders-of-magnitude. Axions have a host of interesting astrophysical and cosmological effects, including, modifying the evolution of stars of all types (our sun, red giants, white dwarfs, and neutron stars), contributing significantly to the mass density of the Universe today, and producing detectable line radiation through the decays of relic axions. Consideration of these effects has probed 14 orders-of-magnitude in axion mass, and has left open only two windows for further exploration: 10/sup /minus/6/ eV /approx lt/ m/sub a/ /approx lt/ 10/sup /minus/3/ eV and 1 eV /approx lt/ m/sub a/ /approx lt/ 5 eV (hadronic axions only). Both these windows are accessible to experiment, and a variety of very interesting experiments, all of which involve ''heavenly axions,'' are being planned or are underway. 58 refs., 6 figs., 1 tab.

  20. A unix configuration engine

    International Nuclear Information System (INIS)

    Burgess, M.

    1994-06-01

    A high level description language is presented for the purpose of automatically configuring large heterogeneous networked unix environments, based on class-oriented abstractions. The configuration engine is portable and easily extensible

  1. Working with Windows 7 at CERN (EN)

    CERN Multimedia

    CERN. Geneva

    2010-01-01

    Overview of new concepts and user interface changes in Windows 7 as compared with older versions of Windows: XP or Vista. Availability of Windows 7 at CERN and its integration with CERN Windows infrastructure will be discussed.

  2. The workplace window view

    DEFF Research Database (Denmark)

    Lottrup, Lene Birgitte Poulsen; Stigsdotter, Ulrika K.; Meilby, Henrik

    2015-01-01

    Office workers’ job satisfaction and ability to work are two important factors for the viability and competitiveness of most companies, and existing studies in contexts other than workplaces show relationships between a view of natural elements and, for example, student performance...... and neighbourhood satisfaction. This study investigates whether relationships between window view, and work ability and job satisfaction also exist in the context of the workplace by focusing on office workers’ view satisfaction. The results showed that a view of natural elements was related to high view...... satisfaction, and that high view satisfaction was related to high work ability and high job satisfaction. Furthermore, the results indicated that job satisfaction mediated the effect of view satisfaction on work ability. These findings show that a view of a green outdoor environment at the workplace can...

  3. Window observers for linear systems

    Directory of Open Access Journals (Sweden)

    Utkin Vadim

    2000-01-01

    Full Text Available Given a linear system x ˙ = A x + B u with output y = C x and a window function ω ( t , i.e., ∀ t , ω ( t ∈ {0,1 }, and assuming that the window function is Lebesgue measurable, we refer to the following observer, x ˆ = A x + B u + ω ( t L C ( x − x ˆ as a window observer. The stability issue is treated in this paper. It is proven that for linear time-invariant systems, the window observer can be stabilized by an appropriate design under a very mild condition on the window functions, albeit for linear time-varying system, some regularity of the window functions is required to achieve observer designs with the asymptotic stability. The corresponding design methods are developed. An example is included to illustrate the possible applications

  4. Beam line windows at LAMPF

    International Nuclear Information System (INIS)

    Brown, R.D.; Grisham, D.L.; Lambert, J.E.

    1985-01-01

    The A-6 main beam-line window at LAMPF separates the vacuum of the main beam line from the isotope production station, proton irradiation ports, and the beam stop, which operate in air. This window must withstand the design beam current of 1 mA at 800 MeV for periods of at least 3000 hours without failure. The window is water cooled and must be strong enough to withstand the 2.1 MPa (300 psig) cooling water pressure, as well as beam-induced thermal stresses. Two designs have been used to meet these goals, a stepped-plate window and a hemispherical window, both made from a precipitation-hardened nickel base alloy, Alloy 718. Calculations of the temperatures and stresses in each of these windows are presented

  5. Windows with improved energy performance

    DEFF Research Database (Denmark)

    Noyé, Peter Anders; Laustsen, Jacob Birck; Svendsen, Svend

    2002-01-01

    . Heat loss through windows represents a considerably part of the total heat loss from houses. However windows provide a unique potential of solar energy gain to the building besides from providing daylight access and view. This results in a need for development of windows with improved energy...... performances. During the last 20 years the U-value of the glazing part of windows has been improved considerably, but the frame part has not followed the same development with respect to energy performance. Therefore an increasingly large part of the total heat loss through windows is relating to the frame...... part, for which reason, as far as energy efficiency and total economy are concerned, it has become more interesting to further develop frame structures. Traditionally, the energy performance of windows has primarily been characterised by the heat loss coefficient, U-value. However as the heat loss has...

  6. Improved Windows for Cold Climates

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    2005-01-01

    A large part of the energy consumption in countries in Nordic and Arctic climates is used for space heating in buildings. In typical buildings the windows are responsible for a con-siderable part of the heat losses. Therefore there is a large potential for energy savings by developing and using...... windows with improved energy performance. Traditionally evaluation of the energy performance of windows has focused on the thermal transmittance, but as windows differ from the rest of the building envelope by allowing solar energy to enter the building, the total solar energy transmittance is equally...... important. In the heating season in cold climates the solar gain through windows can be utilized for space heating which results in a corresponding reduction in the energy production that is often based on fossil fuels. A suitable quantity for evaluating the energy performance of windows in a simple...

  7. HLT configuration management system

    CERN Document Server

    Daponte, Vincenzo

    2015-01-01

    The CMS High Level Trigger (HLT) is implemented running a streamlined version of the CMS offline reconstruction software running on thousands of CPUs. The CMS software is written mostly in C++, using Python as its configuration language through an embedded CPython interpreter. The configuration of each process is made up of hundreds of modules, organized in sequences and paths. As an example, the HLT configurations used for 2011 data taking comprised over 2200 different modules, organized in more than 400 independent trigger paths. The complexity of the HLT configurations and the large number of configuration produced require the design of a suitable data management system. The present work describes the designed solution to manage the considerable number of configurations developed and to assist the editing of new configurations. The system is required to be remotely accessible and OS-independent as well as easly maintainable easy to use. To meet these requirements a three-layers architecture has been choose...

  8. Conceptualizing Embedded Configuration

    DEFF Research Database (Denmark)

    Oddsson, Gudmundur Valur; Hvam, Lars; Lysgaard, Ole

    2006-01-01

    Installing and servicing complex electromechanical systems is more tedious than is necessary. By putting the product knowledge into the product itself, which then would allow automation in constructing the product from modules, could solve that. It would support personnel in aftersales installation...... and services. The general idea can be named embedded configuration. In this article we intend to conceptualize embedded configuration, what it is and is not. The difference between embedded configuration, sales configuration and embedded software is explained. We will look at what is needed to make embedded...... configuration systems. That will include requirements to product modelling techniques. An example with consumer electronics will illuminate the elements of embedded configuration in settings that most can relate to. The question of where embedded configuration would be relevant is discussed, and the current...

  9. An exergy-based multi-objective optimisation model for energy retrofit strategies in non-domestic buildings

    International Nuclear Information System (INIS)

    García Kerdan, Iván; Raslan, Rokia; Ruyssevelt, Paul

    2016-01-01

    While the building sector has a significant thermodynamic improvement potential, exergy analysis has been shown to provide new insight for the optimisation of building energy systems. This paper presents an exergy-based multi-objective optimisation tool that aims to assess the impact of a diverse range of retrofit measures with a focus on non-domestic buildings. EnergyPlus was used as a dynamic calculation engine for first law analysis, while a Python add-on was developed to link dynamic exergy analysis and a Genetic Algorithm optimisation process with the aforementioned software. Two UK archetype case studies (an office and a primary school) were used to test the feasibility of the proposed framework. Different measures combinations based on retrofitting the envelope insulation levels and the application of different HVAC configurations were assessed. The objective functions in this study are annual energy use, occupants' thermal comfort, and total building exergy destructions. A large range of optimal solutions was achieved highlighting the framework capabilities. The model achieved improvements of 53% in annual energy use, 51% of exergy destructions and 66% of thermal comfort for the school building, and 50%, 33%, and 80% for the office building. This approach can be extended by using exergoeconomic optimisation. - Highlights: • Integration of dynamic exergy analysis into a retrofit-oriented simulation tool. • Two UK non-domestic building archetypes are used as case studies. • The model delivers non-dominated solutions based on energy, exergy and comfort. • Exergy destructions of ERMs are optimised using GA algorithms. • Strengths and limitations of the proposed exergy-based framework are discussed.

  10. Windows 7 The Missing Manual

    CERN Document Server

    Pogue, David

    2010-01-01

    In early reviews, geeks raved about Windows 7. But if you're an ordinary mortal, learning what this new system is all about will be challenging. Fear not: David Pogue's Windows 7: The Missing Manual comes to the rescue. Like its predecessors, this book illuminates its subject with reader-friendly insight, plenty of wit, and hardnosed objectivity for beginners as well as veteran PC users. Windows 7 fixes many of Vista's most painful shortcomings. It's speedier, has fewer intrusive and nagging screens, and is more compatible with peripherals. Plus, Windows 7 introduces a slew of new features,

  11. Subject Responses to Electrochromic Windows

    Energy Technology Data Exchange (ETDEWEB)

    Clear, Robert; Inkarojrit, Vorapat; Lee, Eleanor

    2006-03-03

    Forty-three subjects worked in a private office with switchable electrochromic windows, manually-operated Venetian blinds, and dimmable fluorescent lights. The electrochromic window had a visible transmittance range of approximately 3-60%. Analysis of subject responses and physical data collected during the work sessions showed that the electrochromic windows reduced the incidence of glare compared to working under a fixed transmittance (60%) condition. Subjects used the Venetian blinds less often and preferred the variable transmittance condition, but used slightly more electric lighting with it than they did when window transmittance was fixed.

  12. Live histograms in moving windows

    International Nuclear Information System (INIS)

    Zhil'tsov, V.E.

    1989-01-01

    Application of computer graphics for specific hardware testing is discussed. The hardware is position sensitive detector (multiwire proportional chamber) which is used in high energy physics experiments, and real-out electronics for it. Testing program is described (XPERT), which utilises multi-window user interface. Data are represented as histograms in windows. The windows on the screen may be moved, reordered, their sizes may be changed. Histograms may be put to any window, and hardcopy may be made. Some program internals are discussed. The computer environment is quite simple: MS-DOS IBM PC/XT, 256 KB RAM, CGA, 5.25'' FD, Epson MX. 4 refs.; 7 figs

  13. Thermal monitoring of gyrotron windows

    International Nuclear Information System (INIS)

    Huey, H.E.; Choi, E.; Hu, G.; Mundie, L.

    1983-01-01

    In a practical gyrotron device, the design of a reliable vacuum window to withstand high mean power densities is of utmost importance. Computer modelling of an actual window assumes a number of conditions including the power density profile, the electromagnetic wave attenuation constant of the window material and heat transfer coefficients. The last two factors can vary significantly with temperature. A technique for actually monitoring the real time temperature distribution over the window surface with an IR camera while the gyrotron is in operation has been developed. This measurement serves as an aid for developing the analysis of window designs. The ability to observe small hot spots due to tiny metallic specks on the window surface is also of great value in quality control and window failure prevention. The experimental arrangement involves an infrared camera (AGA780) with an indium antimonide detector (3-5 μm) observing the window through a grid pattern of tiny holes (cutoff for the 3rd harmonic of 60 GHz). A 12 0 FOV lens with a 12mm extension ring was used to defocus the grid. The thermal emissivity E /sub w/ approx. = 0.95. Thus, an IR measurement of the window is a surface temperature measurement. To minimize the problem of external reflections, the outside surface of the waveguide was painted black. This then requires a cool waveguide; room temperature is sufficient

  14. Microsoft Windows Operating System Essentials

    CERN Document Server

    Carpenter, Tom

    2012-01-01

    A full-color guide to key Windows 7 administration concepts and topics Windows 7 is the leading desktop software, yet it can be a difficult concept to grasp, especially for those new to the field of IT. Microsoft Windows Operating System Essentials is an ideal resource for anyone new to computer administration and looking for a career in computers. Delving into areas such as fundamental Windows 7 administration concepts and various desktop OS topics, this full-color book addresses the skills necessary for individuals looking to break into a career in IT. Each chapter begins with a list of topi

  15. Beginning Windows 8.1

    CERN Document Server

    Halsey, Mike

    2013-01-01

    Windows 8 has been described by Microsoft as its 'boldest' Windows release ever and the 8.1 update enhances the paradigm further. Beginning Windows 8.1 takes you through the new features and helps you get more out of the familiar to reveal the fullest possibilities for this amazing new operating system. You will learn, with non-technical language used throughout, how to get up and running in the new Windows interface, minimize downtime, maximize productivity, and harness the features you never knew existed to take control of your computer and enjoy the peace of mind and excitement that comes w

  16. Resource handbook for low-income residential retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Callaway, J.W.; Brenchley, D.L.; Davis, L.J.; Ivey, D.L.; Smith, S.A.; Westergard, E.J.

    1987-04-01

    The purpose of the handbook is to provide technical assistance to state grantees participating in the Partnerships in Low-Income Residential Retrofit (PILIRR) Program. PILIRR is a demonstration program aimed at identifying innovative, successful approaches to developing public and private support for weatherization of low-income households. The program reflects the basic concept that responsibility for financial support for conservation activities such as low-income residential retrofitting is likely to gradually shift from the DOE to the states and the private sector. In preparing the handbook, PNL staff surveyed over 50 programs that provide assistance to low-income residents. The survey provided information on factors that contribute to successful programs. PNL also studied the winning PILIRR proposals (from the states of Florida, Iowa, Kentucky, Oklahoma and Washington) and identified the approaches proposed and the type of information that would be most helpful in implementing these approaches.

  17. Evolution of the CANDU control centre retrofit and new stations

    International Nuclear Information System (INIS)

    Olmstead, R.A.; Mitchell, W.

    1991-01-01

    Significant event data from operating nuclear plants in many countries consistently indicates human errors are the root cause for 40-60% of operating station significant events. Because so much information is already in digital form, opportunities exist to improve the CANDU control centre with retrofits that exploit this information. These opportunities are enhanced because of rapid technological development in computers and electronics, coupled with significant progress in the behavioural sciences that greatly increases our knowledge of the cognitive strengths and weaknesses of human beings. CANDU control rooms are undergoing retrofits and for future CANDU stations, a new concept of the control centre is emerging. The objective is to significantly reduce the incidence of human error, reduce operations and maintenance costs and improve both reliability and safety

  18. A Wireless Platform for Energy Efficient Building Control Retrofits

    Science.gov (United States)

    2012-07-01

    equipment condition; (iii) building size (7000 sq. ft. space) and usage (mixed with offices , conference rooms, cubicles and a cafeteria having different...IL) was demonstrated. The medium-size office building underwent a retrofit of the HVAC system and controls employing a technology called optimal...gratefully acknowledge the financial support and technical guidance provided by the SERDP/ESTCP Office under the leadership of leadership Drs. Jeff

  19. Energy Efficient Crawlspace Foundation Retrofit: Mixed Humid Climate

    Energy Technology Data Exchange (ETDEWEB)

    Del Bianco, M.; Wiehagen, J.; Wood, A.

    2013-01-01

    Residential quality management systems have most often been designed for new home construction. To address quality in existing homes in the form of Scopes of Work (SOW), the NAHB Research Center began with a new construction scope of work and applied it to an existing home project. This document is intended to outline the steps of translating a new home construction SOW to SOW for retrofit.

  20. Energy Efficient Crawlspace Foundation Retrofit: Mixed Humid Climate

    Energy Technology Data Exchange (ETDEWEB)

    Del Bianco, M. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Wiehagen, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States)

    2013-01-01

    Residential quality management systems have most often been designed for new home construction. To address quality in existing homes in the form of Scopes of Work (SOW), the NAHB Research Center began with a new construction scope of work and applied it to an existing home project. This document is intended to outline the steps of translating a new home construction SOW to SOW for retrofit and addressed crawlspace foundations in a mixed-humid climate.

  1. A Proposed Retrofit for Bridges Subjected to Wave Forces

    OpenAIRE

    Govan, Paul

    2010-01-01

    Damage due to recent hurricanes along the Gulf Coast of Mexico publicized the need for research of engineering practices in coastal areas. Specifically, many bridges near the coast were not designed for storm surge and wind induced wave loads. Many of these damaged bridges are being rebuilt higher with correspondingly higher costs. The following proposal concerns using existing seismic retrofitting techniques for simply supported bridges as a solution to this problem. The proposed connection ...

  2. Next Step Toward Widespread Residential Deep Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    McIlvaine, J.; Saunders, S.; Bordelon, E.; Baden, S.; Elam, L.; Martin, E.

    2013-07-01

    The complexity of deep energy retrofits warrants additional training to successfully manage multiple improvements that will change whole house air, heat, and moisture flow dynamics. The home performance contracting industry has responded to these challenges by aggregating skilled labor for assessment of and implementation under one umbrella. Two emerging business models are profiled that seek to resolve many of the challenges, weaknesses, opportunities, and threats described for the conventional business models.

  3. The Next Step Toward Widespread Residential Deep Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    McIlvaine, J. [Building American Partnership for Residential Construction (BA-PIRC), Cocoa, FL (United States); Martin, E. [Building American Partnership for Residential Construction (BA-PIRC), Cocoa, FL (United States); Saunders, S. [Building American Partnership for Residential Construction (BA-PIRC), Cocoa, FL (United States); Bordelon, E. [Building American Partnership for Residential Construction (BA-PIRC), Cocoa, FL (United States); Baden, S. [Building American Partnership for Residential Construction (BA-PIRC), Cocoa, FL (United States); Elam, L. [Building American Partnership for Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2013-07-01

    The complexity of deep energy retrofits warrants additional training to successfully manage multiple improvements that will change whole house air, heat, and moisture flow dynamics. The home performance contracting industry has responded to these challenges by aggregating skilled labor for assessment of and implementation under one umbrella. Two emerging business models are profiled that seek to resolve many of the challenges, weaknesses, opportunities, and threats described for the conventional business models.

  4. Retrofitted gravity mediation without the gravitino-overproduction problem

    International Nuclear Information System (INIS)

    Endo, M.; Takahashi, F.; Yanagida, T.T.; Tokyo Univ.

    2007-02-01

    We propose a retrofitted gravity mediation model which alleviates the gravitino overproduction from decays of an inflaton and a supersymmetry breaking field. In the model, we introduce an approximate U(1) symmetry under which the supersymmetry breaking field is charged, although it is broken by a mass term of messenger fields to generate gaugino masses of order the weak scale. In a low-scale inflation model, we find regions in which the gravitino overproduction problem is avoided. (orig.)

  5. Optically transmissive window on ITER port cell door

    International Nuclear Information System (INIS)

    Patel, Kunal; Walsh, Mike; Phillips, Guy; Parsons, Phil; Balshaw, Nick; Hank, Simon

    2009-01-01

    In the ITER Thomson Scattering Core LIDAR system there are currently three concepts for collecting scattered light from the plasma and delivering it to the diagnostic room. An option to use a broadband mirror in Cassegrain configuration has been explored. In this concept a large optical window, 1.5 m in diameter, is required in the port cell door. This could be manufactured in a number of ways, including using a single thick window or mosaic arrangement with a supporting structure. Challenges associated with this design include maintaining the secondary confinement barrier, withstanding a pressure differential of 0.5 bar across the window in foreseeable fault conditions, and maintaining the optical properties of the window. It must also be possible to protect the window when work is being carried out in the area. Fracture analysis for brittle material was carried out, for a flaw size with a length to depth ratio of 80/20, which gave a safety reserve factor of 4. The flaw size was based on a standard optical transmissive lens for collection light. A static analysis was carried out on both options of having a single thick glass window or a mosaic arrangement. The principal stress for a single window arrangement is 12 MPa and for a proposed mosaic arrangement is 12.5 MPa. The analyses have demonstrated that a single glass window with a thickness of 42 mm would be mechanically acceptable but expensive to manufacture and it would be difficult to polish glass of that size to lens quality. By comparison in the proposed mosaic window arrangement, the glass thickness is reduced by 50% with the aid of the supporting structure. As a result of the supporting structure the geometrical optical losses are 4%, which are mechanically and optically acceptable, whilst significantly reducing the cost of manufacturing.

  6. Windows forensic analysis toolkit advanced analysis techniques for Windows 7

    CERN Document Server

    Carvey, Harlan

    2012-01-01

    Now in its third edition, Harlan Carvey has updated "Windows Forensic Analysis Toolkit" to cover Windows 7 systems. The primary focus of this edition is on analyzing Windows 7 systems and on processes using free and open-source tools. The book covers live response, file analysis, malware detection, timeline, and much more. The author presents real-life experiences from the trenches, making the material realistic and showing the why behind the how. New to this edition, the companion and toolkit materials are now hosted online. This material consists of electronic printable checklists, cheat sheets, free custom tools, and walk-through demos. This edition complements "Windows Forensic Analysis Toolkit, 2nd Edition", (ISBN: 9781597494229), which focuses primarily on XP. It includes complete coverage and examples on Windows 7 systems. It contains Lessons from the Field, Case Studies, and War Stories. It features companion online material, including electronic printable checklists, cheat sheets, free custom tools, ...

  7. High-Efficiency Retrofit Lessons for Retail from a SuperTarget: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Langner, R.; Deru, M.; Hirsch, A.; Williams, S.

    2013-02-01

    The National Renewable Energy Laboratory partnered with Target under the Commercial Building Program to design and implement a retrofit of a SuperTarget in Thornton, CO. The result was a retrofit design that predicted 37% energy savings over ASHRAE Standard 90.1-2004, and 29% compared to existing (pre-retrofit) store consumption. The largest savings came from energy efficient lighting, energy efficient cooling systems, improved refrigeration, and better control of plug loads.

  8. Byggmeister Test Home. Analysis and Initial Results of Cold Climate Wood-Framed Home Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Gates, C. [Building Science Corporation (BSC), Somerville, MA (United States)

    2013-01-01

    BSC seeks to further the energy efficiency market for New England area retrofit projects by supporting projects that are based on solid building science fundamentals that will benefit the homeowner through a combination of energy savings, improved durability, and occupant comfort. This report describes a deep retrofit project of a two-family wood-framed home in Belmont, Massachusetts, and examines the retrofit measures for the enclosure amd mechanical systems and reviews the decision-making process that took place during planning.

  9. Thermo economical evaluation of retrofitting strategies in air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Tribess, Arlindo; Fiorelli, Flavio Augusto Sanzogo; Hernandez Neto, Alberto [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia Mecanica]. E-mail: atribess@usp.br; fiorelli@usp.br; ahneto@usp.br

    2000-07-01

    In a building project, several subsystems are designed, among them the air conditioning system. Electrical energy consumption profiles show that this subsystem is responsible for 40 to 50% of total consumption in a commercial building. Besides the study of technical aspects that should be considered in order to assure the thermal comfort of the occupants as well the temperature and humidity conditions for an efficient equipment operation, an economical evaluation of this subsystem should be also made. In retrofit projects, the economical aspect is also critical for such projects in order to assure bigger efficiency in an economically attractive way. This paper analyses some strategies that might be adopted in retrofitting an air conditioning system installed in a commercial building with mixed occupation. By mixed we mean that some floors have a typical office occupation profile and other floors are mainly occupied by electronic equipment. This analysis includes both technical and economical evaluation. The proposed solutions performance are compared to the old system, which allows to verify the retrofitting impact in energy consumption reduction and its economical feasibility. (author)

  10. Field Assessment of Energy Audit Tools for Retrofit Programs

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, J.; Bohac, D.; Nelson, C.; Smith, I.

    2013-07-01

    This project focused on the use of home energy ratings as a tool to promote energy retrofits in existing homes. A home energy rating provides a quantitative appraisal of a home's asset performance, usually compared to a benchmark such as the average energy use of similar homes in the same region. Home rating systems can help motivate homeowners in several ways. Ratings can clearly communicate a home's achievable energy efficiency potential, provide a quantitative assessment of energy savings after retrofits are completed, and show homeowners how they rate compared to their neighbors, thus creating an incentive to conform to a social standard. An important consideration is how rating tools for the retrofit market will integrate with existing home energy service programs. For residential programs that target energy savings only, home visits should be focused on key efficiency measures for that home. In order to gain wide adoption, a rating tool must be easily integrated into the field process, demonstrate consistency and reasonable accuracy to earn the trust of home energy technicians, and have a low monetary cost and time hurdle for homeowners. Along with the Home Energy Score, this project also evaluated the energy modeling performance of SIMPLE and REM/Rate.

  11. Deep Energy Retrofit Performance Metric Comparison: Eight California Case Studies

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisher, Jeremy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Less, Brennan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-06-01

    In this paper we will present the results of monitored annual energy use data from eight residential Deep Energy Retrofit (DER) case studies using a variety of performance metrics. For each home, the details of the retrofits were analyzed, diagnostic tests to characterize the home were performed and the homes were monitored for total and individual end-use energy consumption for approximately one year. Annual performance in site and source energy, as well as carbon dioxide equivalent (CO2e) emissions were determined on a per house, per person and per square foot basis to examine the sensitivity to these different metrics. All eight DERs showed consistent success in achieving substantial site energy and CO2e reductions, but some projects achieved very little, if any source energy reduction. This problem emerged in those homes that switched from natural gas to electricity for heating and hot water, resulting in energy consumption dominated by electricity use. This demonstrates the crucial importance of selecting an appropriate metric to be used in guiding retrofit decisions. Also, due to the dynamic nature of DERs, with changes in occupancy, size, layout, and comfort, several performance metrics might be necessary to understand a project’s success.

  12. Move over! Stock turnover, retrofit and industrial energy efficiency

    International Nuclear Information System (INIS)

    Worrell, Ernst; Biermans, Gijs

    2005-01-01

    We demonstrate the importance of stock turnover on industrial energy efficiency through a literature review and a case study of energy-intensive equipment, i.e. the electric arc furnace in the US steel industry. We describe the common methods for assessing stock turnover. We have found that both stock turnover and retrofit are important elements to explain the energy efficiency improvement rates. We investigated the development of electricity use in electric arc furnaces in the United States by tracking the development of individual furnaces over the period 1990-2002. This provides a detailed picture of changes in the stock or fleet of furnaces through turnover and/or retrofit. Our results confirm the results of other empirical studies that there is no clear lifetime of equipment. However, retired furnaces are distinctly less efficient than furnaces remaining in the stock, while new furnaces are distinctly more efficient than the average stock. We found an annual average improvement in specific electricity consumption of 1.3%/year over the studied period, of which 0.7%/year was due to stock turnover and 0.5%/year due to retrofit of stock in service throughout the period

  13. Experiment study on RC frame retrofitted by the external structure

    Science.gov (United States)

    Liu, Chunyang; Shi, Junji; Hiroshi, Kuramoto; Taguchi, Takashi; Kamiya, Takashi

    2016-09-01

    A new retrofitting method is proposed herein for reinforced concrete (RC) structures through attachment of an external structure. The external structure consists of a fiber concrete encased steel frame, connection slab and transverse beams. The external structure is connected to the existing structure through a connection slab and transverse beams. Pseudostatic experiments were carried out on one unretrofitted specimen and three retrofitted frame specimens. The characteristics, including failure mode, crack pattern, hysteresis loops behavior, relationship of strain and displacement of the concrete slab, are demonstrated. The results show that the load carrying capacity is obviously increased, and the extension length of the slab and the number of columns within the external frame are important influence factors on the working performance of the existing structure. In addition, the displacement difference between the existing structure and the outer structure was caused mainly by three factors: shear deformation of the slab, extraction of transverse beams, and drift of the conjunction part between the slab and the existing frame. Furthermore, the total deformation determined by the first two factors accounted for approximately 80% of the damage, therefore these factors should be carefully considered in engineering practice to enhance the effects of this new retrofitting method.

  14. Sourcing of Steam and Electricity for Carbon Capture Retrofits.

    Science.gov (United States)

    Supekar, Sarang D; Skerlos, Steven J

    2017-11-07

    This paper compares different steam and electricity sources for carbon capture and sequestration (CCS) retrofits of pulverized coal (PC) and natural gas combined cycle (NGCC) power plants. Analytical expressions for the thermal efficiency of these power plants are derived under 16 different CCS retrofit scenarios for the purpose of illustrating their environmental and economic characteristics. The scenarios emerge from combinations of steam and electricity sources, fuel used in each source, steam generation equipment and process details, and the extent of CO 2 capture. Comparing these scenarios reveals distinct trade-offs between thermal efficiency, net power output, levelized cost, profit, and net CO 2 reduction. Despite causing the highest loss in useful power output, bleeding steam and extracting electric power from the main power plant to meet the CCS plant's electricity and steam demand maximizes plant efficiency and profit while minimizing emissions and levelized cost when wholesale electricity prices are below 4.5 and 5.2 US¢/kWh for PC-CCS and NGCC-CCS plants, respectively. At prices higher than these higher profits for operating CCS retrofits can be obtained by meeting 100% of the CCS plant's electric power demand using an auxiliary natural gas turbine-based combined heat and power plant.

  15. Windows phone recipes A problem-solution approach

    CERN Document Server

    Ferracchiati, Fabio Claudio

    2011-01-01

    Developers are racing to discover how to develop for Windows Phone 7 - and there is no quicker resource to help you get up to speed than Windows Phone 7 Recipes. It covers all aspects of development, configuration, testing, and distribution, with detailed code samples and rapid walkthroughs. You'll find recipes that unlock advanced user interface development, data storage and retrieval, integration with cloud services, adding media and location-based services, and working with Silverlight and Expression Blend. Learn to use sensors such as the camera, GPS, and accelerometer to build cutting-edg

  16. Learning Windows Azure Mobile Services for Windows 8 and Windows Phone 8

    CERN Document Server

    Webber-Cross, Geoff

    2014-01-01

    This book is based around a case study game which was written for the book. This means that the chapters progress in a logical way and build upon lessons learned as we go. Real-world examples are provided for each topic that are practical and not given out-of-context so they can be applied directly to other applications.If you are a developer who wishes to build Windows 8 and Phone 8 applications and integrate them with Windows Azure Mobile Services, this book is for you. Basic C# and JavaScript skills are advantageous, as well as some knowledge of building Windows 8 or Windows Phone 8 applica

  17. Protocol for Maximizing Energy Savings and Indoor Environmental Quality Improvements when Retrofiting Apartments

    Energy Technology Data Exchange (ETDEWEB)

    Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Delp, William W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vermeer, Kimberly [Urban Habitat Initiatives Inc., Boston, MA (United States); Adamkiewicz, Gary [Harvard School of Public Health, Boston, MA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-06-18

    The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

  18. Protocol for maximizing energy savings and indoor environmental quality improvements when retrofitting apartments

    Energy Technology Data Exchange (ETDEWEB)

    Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Delp, William W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vermeer, Kimberly [Urban Habitat Initiatives Inc., Boston, MA (United States); Adamkiewicz, Gary [Harvard School of Public Health, Boston, MA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-06-01

    The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

  19. Residual heat removal pump retrofit program

    International Nuclear Information System (INIS)

    Dudiak, J.G.; McKenna, J.M.

    1990-01-01

    Residual Heat Removal (RHR) pumps installed in pressurized water reactor power plants are used to provide the removal of decay heat from the reactor and to provide low head safety injection in the event of loss of coolant in the reactor coolant system. These pumps are subjected to rather severe temperature and pressure transients, therefore, the majority of pumps installed in the RHR service are vertical pumps with a single stage impeller. RHR pumps have traditionally been a significant maintenance item for many utilities. The close-coupled pump design requires disassembly of the casing cover from the lower pump casing while performing these routine maintenance tasks. The casing separation requires the loosening of numerous highly torqued studs. Once the casing is separated, the impeller is dropped from the motor shaft to allow removal of the mechanical seal and casing cover from the motor shaft. Galling of the impeller to the motor shaft is not uncommon. The RHR pump internals are radioactive and the separation of the pump casing to perform routine maintenance exposes the maintenance personnel to high radiation levels. The handling of the impeller also exposes the maintenance personnel to high radiation levels. This paper introduces a design modification developed to convert the close-coupled RHR pumps to a coupled configuration

  20. Window prototypes during the project

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe

    1996-01-01

    The conditions for the PASSYS test and the results of the measurements on one of the aerogel window prototypes are described.......The conditions for the PASSYS test and the results of the measurements on one of the aerogel window prototypes are described....

  1. Thermal bridges of modern windows

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan de Place; Møller, Eva B.; Nielsen, Anker

    2013-01-01

    With its focus on reduced energy consumption, contemporary housing construction requires a highly insulated and airtight building envelope with as few thermal bridges as possible.Windows must be carefully designed, as thermal bridges can lead to surface condensation or mold growth, even if the wi......With its focus on reduced energy consumption, contemporary housing construction requires a highly insulated and airtight building envelope with as few thermal bridges as possible.Windows must be carefully designed, as thermal bridges can lead to surface condensation or mold growth, even...... if the window has an U-factor of 1 W/(m2·K) or lower. This paper describes the development of modern, energy efficient Danish windows with reduced thermal bridges. It focuses on materials, geometry, and sealing of window panes based on a literature review. Examples of modern windows are presented. Experience...... been an important driver for the development of new window solutions in Denmark, increasing the inner-surface temperature at the sealing of window panes. However, it will not stop complaints fromconsumers, as this temperature is calculated under standardized conditions. Increasing requirements...

  2. Characterization of Energy Savings and Thermal Comfort Improvements Derived from Using Interior Storm Windows

    Energy Technology Data Exchange (ETDEWEB)

    Knox, Jake R.; Widder, Sarah H.

    2013-09-30

    This field study of a single historic home in Seattle, WA documents the performance of Indow Windows’s interior storm window inserts. Energy use and the temperature profile of the house were monitored before and after the installation of the window inserts and changes in the two recorded metrics were examined. Using the defined analysis approach, it was determined that the interior storm windows produced a 22% reduction of the HVAC energy bill and had an undetermined effect on the thermal comfort in the house. Although there was no measurable changes in the thermal comfort of the house, the occupant noted the house to be “warmer in the winter and cooler in the summer” and that the “temperatures are more even (throughout the house).” The interior storm windows were found to be not cost effective, largely due to the retrofits completed on its heating system. However, if the economic analysis was conducted based on the old heating system, a 72% efficient oil fired furnace, the Indow Windows proved to be economical and had a simple payback period of 9.0 years.

  3. Software configuration management

    CERN Document Server

    Keyes, Jessica

    2004-01-01

    Software Configuration Management discusses the framework from a standards viewpoint, using the original DoD MIL-STD-973 and EIA-649 standards to describe the elements of configuration management within a software engineering perspective. Divided into two parts, the first section is composed of 14 chapters that explain every facet of configuration management related to software engineering. The second section consists of 25 appendices that contain many valuable real world CM templates.

  4. Inventions on Displaying and Resizing Windows

    OpenAIRE

    Mishra, Umakant

    2014-01-01

    Windows are used quite frequently in a GUI environment. The greatest advantage of using windows is that each window creates a virtual screen space. Hence, although the physical screen space is limited to a few inches, use of windows can create unlimited screen space to display innumerable items. The use of windows facilitates the user to open and interact with multiple programs or documents simultaneously in different windows. Sometimes a single program may also open multiple windows to displ...

  5. Destiny's Earth Observation Window

    Science.gov (United States)

    2002-01-01

    Astronaut Michael J. Bloomfield, STS-110 mission commander, looks through the Earth observation window in the Destiny laboratory aboard the International Space Station (ISS). The STS-110 mission prepared the ISS for future spacewalks by installing and outfitting the S0 (S-zero) truss and the Mobile Transporter. The 43-foot-long S0 Truss, weighing in at 27,000 pounds, was the first of 9 segments that will make up the Station's external framework that will eventually stretch 356 feet (109 meters), or approximately the length of a football field. This central truss segment also includes a flatcar called the Mobile Transporter and rails that will become the first 'space railroad,' which will allow the Station's robotic arm to travel up and down the finished truss for future assembly and maintenance. The completed truss structure will hold solar arrays and radiators to provide power and cooling for additional international research laboratories from Japan and Europe that will be attached to the Station. Milestones of the STS-110 mission included the first time the ISS robotic arm was used to maneuver spacewalkers around the Station and marked the first time all spacewalks were based out of the Station's Quest Airlock. It was also the first Shuttle to use three Block II Main Engines. The Space Shuttle Orbiter Atlantis, STS-110 mission, was launched April 8, 2002 and returned to Earth April 19, 2002.

  6. CONFIGURATION GENERATOR MODEL

    Energy Technology Data Exchange (ETDEWEB)

    A. Alsaed

    2004-11-18

    ''The Disposal Criticality Analysis Methodology Topical Report'' prescribes an approach to the methodology for performing postclosure criticality analyses within the monitored geologic repository at Yucca Mountain, Nevada. An essential component of the methodology is the ''Configuration Generator Model for In-Package Criticality'' that provides a tool to evaluate the probabilities of degraded configurations achieving a critical state. The configuration generator model is a risk-informed, performance-based process for evaluating the criticality potential of degraded configurations in the monitored geologic repository. The method uses event tree methods to define configuration classes derived from criticality scenarios and to identify configuration class characteristics (parameters, ranges, etc.). The probabilities of achieving the various configuration classes are derived in part from probability density functions for degradation parameters. The NRC has issued ''Safety Evaluation Report for Disposal Criticality Analysis Methodology Topical Report, Revision 0''. That report contained 28 open items that required resolution through additional documentation. Of the 28 open items, numbers 5, 6, 9, 10, 18, and 19 were concerned with a previously proposed software approach to the configuration generator methodology and, in particular, the k{sub eff} regression analysis associated with the methodology. However, the use of a k{sub eff} regression analysis is not part of the current configuration generator methodology and, thus, the referenced open items are no longer considered applicable and will not be further addressed.

  7. Configuration management at NEK

    International Nuclear Information System (INIS)

    Podhraski, M.

    1999-01-01

    Configuration Management (CM) objectives at NEK are to ensure consistency between Design Requirements, Physical Plant Configuration and Configuration Information. Software applications, supporting Design Change, Work Control and Document Control Processes, are integrated in one module-oriented Management Information System (MIS). Master Equipment Component List (MECL) database is central MIS module. Through a combination of centralized database and process migrated activities it is ensured that the CM principles and requirements (accurate, current design data matching plant's physical configuration while complying to applicable requirements), are followed and fulfilled.(author)

  8. Improved Windows for Cold Climates

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    2005-01-01

    considerably by reducing the frame width, which results in a larger transparent area causing a larger solar gain but still main-taining a low thermal transmittance. Using three layers of glass with large gaps, using very slim frame profiles, and omitting the edge constructions that normally causes thermal...... windows with improved energy performance. Traditionally evaluation of the energy performance of windows has focused on the thermal transmittance, but as windows differ from the rest of the building envelope by allowing solar energy to enter the building, the total solar energy transmittance is equally...... important. In the heating season in cold climates the solar gain through windows can be utilized for space heating which results in a corresponding reduction in the energy production that is often based on fossil fuels. A suitable quantity for evaluating the energy performance of windows in a simple...

  9. Windows for tablets for dummies

    CERN Document Server

    Rathbone, Andy

    2013-01-01

    Just for you--Windows 8 from the tablet user's perspective If you're an experienced Windows user, you don't need a guide to everything that Windows 8 can do, just to those tools and functions that work on your tablet. And so here it is. This new book zeros in on what you need to know to work best on your tablet with Windows 8. Topics include navigating the new Windows 8 interface and how it works on a touchscreen, how to safely connect to the Internet, how to work with apps or share your tablet in a group, and much more. If you're a new tablet user, you'll particularly appre

  10. Handbook on Windows and Energy

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Schultz, Jørgen Munthe; Svendsen, Sv Aa Højgaard

    transmission through windows is described in detail including radiation, convection and conduction as well as solar transmittance of window glazing. The most used terms related to characterization of window energy performance are defined and calculation methods according to international standards...... flow and detailed calculation of light and solar transmittance is given.Different measurement techniques for characterization of window heat loss coefficient and total solar energy transmittance is described and references to interantional standards are given.Finally, the handbook includes...... a comprehensive list of window related standards and a list of Nordic research and development projects.Two programs are encloased in the handbook for calculation of solar radiation on inclined surfaces including a shadow correction and a simple program for evaluation of energy savings and risk of overtemperature....

  11. False Windows - Yesterday and Today

    Science.gov (United States)

    Niewitecki, Stefan

    2017-10-01

    The article is concerned with a very interesting aspect of architectural design, namely, a contradiction between the building functions and the necessity of giving the building a desired external appearance. One of the possibilities of reconciling this contradiction is using pseudo windows that are visible on the elevation and generally have the form of a black painted recess accompanied by frames and sashes and often single glazing. Of course, there are no windows or openings in the corresponding places in the walls inside the building. The article discusses the differences between false windows and blind widows (German: blende), also known as blank windows, which, in fact, are shallow recesses in the wall having the external appearance of an arcade or a window and which had already been used in Gothic architecture mostly for aesthetic reasons and sometimes to reduce the load of the wall. Moreover, the article describes various false windows that appeared later than blind windows because they did not appear until the 17th century. Contemporary false windows are also discussed and it is shown that contrary to the common belief they are widely used. In his research, the author not only used the Internet data but also carried out his own in situ exploration. The false windows constitute very interesting albeit rare elements of the architectural design of buildings. They have been used successfully for a few hundred years. It might seem that they should have been discarded by now but this has not happened. Quite contrary, since the second half of the 20th century there has been a rapid development of glass curtain walls that serve a similar function in contemporary buildings as the false windows once did, only in a more extensive way.

  12. Retrofitting Of RCC Piles By Using Basalt Fiber Reinforced Polymer BFRP Composite Part 1 Review Papers On RCC Structures And Piles Retrofitting Works.

    Directory of Open Access Journals (Sweden)

    R. Ananda Kumar

    2015-01-01

    Full Text Available Abstract Retrofitting works are immensely essential for deteriorated and damaged structures in Engineering and Medical fields in order to keep or return to the originality for safe guarding the structures and consumers. In this paper different types of methods of retrofitting review notes are given based on the experimental numerical and analytical methods results on strengthening the Reinforced cement concrete RCC structures including RCC piles. Soil-pile interaction on axial load lateral load reviews are also presented. This review paper is prepared to find out the performance of basalt fibre reinforced polymer BFRP composite retrofitted reinforced cement concrete single end bearing piles.

  13. PIV Logon Configuration Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Glen Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-04

    This document details the configurations and enhancements implemented to support the usage of federal Personal Identity Verification (PIV) Card for logon on unclassified networks. The guidance is a reference implementation of the configurations and enhancements deployed at the Los Alamos National Laboratory (LANL) by Network and Infrastructure Engineering – Core Services (NIE-CS).

  14. Global Value Chain Configuration

    DEFF Research Database (Denmark)

    Hernandez, Virginia; Pedersen, Torben

    2017-01-01

    This paper reviews the literature on global value chain configuration, providing an overview of this topic. Specifically, we review the literature focusing on the concept of the global value chain and its activities, the decisions involved in its configuration, such as location, the governance mo...

  15. Simulator configuration maintenance

    International Nuclear Information System (INIS)

    2006-01-01

    Requirements and recommendations of this section defines NPP personnel activity aimed to the provision of the simulator configuration compliance with the current configuration of the power-generating unit-prototype, standard and technical requirements and describe a monitoring procedure for a set of simulator software and hardware, training, organizational and technical documents

  16. Risk-based configuration control

    International Nuclear Information System (INIS)

    Szikszai, T.

    1997-01-01

    The presentation discusses the following issues: The Configuration Control; The Risk-based Configuration Control (during power operation mode, and during shutdown mode). PSA requirements. Use of Risk-based Configuration Control System. Configuration Management (basic elements, benefits, information requirements)

  17. Business Model Process Configurations

    DEFF Research Database (Denmark)

    Taran, Yariv; Nielsen, Christian; Thomsen, Peter

    2015-01-01

    strategic preference, as part of their business model innovation activity planned. Practical implications – This paper aimed at strengthening researchers and, particularly, practitioner’s perspectives into the field of business model process configurations. By insuring an [abstracted] alignment between......Purpose – The paper aims: 1) To develop systematically a structural list of various business model process configuration and to group (deductively) these selected configurations in a structured typological categorization list. 2) To facilitate companies in the process of BM innovation......, by developing (inductively) an ontological classification framework, in view of the BM process configurations typology developed. Design/methodology/approach – Given the inconsistencies found in the business model studies (e.g. definitions, configurations, classifications) we adopted the analytical induction...

  18. Low-E Storm Windows Gain Acceptance as a Home Weatherization Measure

    Energy Technology Data Exchange (ETDEWEB)

    Gilbride, Theresa L.; Cort, Katherine A.

    2016-05-16

    This article for Home Energy Magazine describes work by the U.S. Department of Energy to develop low-emissivity storm windows as an energy efficiency-retrofit option for existing homes. The article describes the low-emissivity invisible silver metal coatings on the glass, which reflect heat back into the home in winter or back outside in summer and the benefits of low-e storm windows including insulation, air sealing, noise blocking, protection of antique windows, etc. The article also describes Pacific Northwest National Laboratory's efforts on behalf of DOE to overcome market barriers to adoption of the technology, including performance validation studies in the PNNL Lab Homes, cost effectiveness analysis, production of reports, brochures, how-to guides on low-e storm window installation for the Building America Solution Center, and a video posted on YouTube. PNNL's efforts were reviewed by the Pacific Northwest Regional Technical Forum (RTF), which serves as the advisory board to the Pacific Northwest Electric Power Planning Council and Bonneville Power Administration. In late July 2015, the RTF approved the low-e storm window measure’s savings and specifications, a critical step in integrating low-e storm windows into energy-efficiency planning and utility weatherization and incentive programs. PNNL estimates that more than 90 million homes in the United States with single-pane or low-performing double-pane windows would benefit from the technology. Low-e storm windows are suitable not only for private residences but also for small commercial buildings, historic properties, and facilities that house residents, such as nursing homes, dormitories, and in-patient facilities. To further assist in the market transformation of low-e storm windows and other high-efficiency window attachments, DOE helped found the window Attachment Energy Rating Council (AERC) in 2015. AERC is an independent, public interest, non-profit organization whose mission is to rate

  19. Windows 8 visual quick tips

    CERN Document Server

    McFedries, Paul

    2012-01-01

    Easy-in, easy-out format covers all the bells and whistles of Windows 8 If you want to learn how to work smarter and faster in Microsoft's Windows 8 operating system, this easy-to-use, compact guide delivers the goods. Designed for visual learners, it features short explanations and full-color screen shots on almost every page, and it's packed with timesaving tips and helpful productivity tricks. From enhancing performance and managing digital content to setting up security and much more, this handy guide will help you get more out of Windows 8. Uses full-color screen shots and short, step-by-

  20. Transparent solar cell window module

    Energy Technology Data Exchange (ETDEWEB)

    Chau, Joseph Lik Hang; Chen, Ruei-Tang; Hwang, Gan-Lin; Tsai, Ping-Yuan [Nanopowder and Thin Film Technology Center, ITRI South, Industrial Technology Research Institute, Tainan County 709 (China); Lin, Chien-Chu [I-Lai Acrylic Corporation, Tainan City (China)

    2010-03-15

    A transparent solar cell window module based on the integration of traditional silicon solar cells and organic-inorganic nanocomposite material was designed and fabricated. The transparent solar cell window module was composed of a nanocomposite light-guide plate and traditional silicon solar cells. The preparation of the nanocomposite light-guide plate is easy without modification of the traditional casting process, the nanoparticles sol can be added directly to the polymethyl methacrylate (PMMA) monomer syrup during the process. The solar energy collected by this window can be used to power up small household electrical appliances. (author)

  1. Big Book of Windows Hacks

    CERN Document Server

    Gralla, Preston

    2008-01-01

    Bigger, better, and broader in scope, the Big Book of Windows Hacks gives you everything you need to get the most out of your Windows Vista or XP system, including its related applications and the hardware it runs on or connects to. Whether you want to tweak Vista's Aero interface, build customized sidebar gadgets and run them from a USB key, or hack the "unhackable" screensavers, you'll find quick and ingenious ways to bend these recalcitrant operating systems to your will. The Big Book of Windows Hacks focuses on Vista, the new bad boy on Microsoft's block, with hacks and workarounds that

  2. Windows Phone 7 Made Simple

    CERN Document Server

    Trautschold, Martin

    2011-01-01

    With Windows Phone 7, Microsoft has created a completely new smartphone operating system that focuses on allowing users to be productive with their smartphone in new ways, while offering seamless integration and use of Microsoft Office Mobile as well as other productivity apps available in the Microsoft App Store. Windows Phone 7 Made Simple offers a clear, visual, step-by-step approach to using your Windows Phone 7 smartphone, no matter what the manufacturer. Author Jon Westfall is an expert in mobile devices, recognized by Microsoft as a "Most Valuable Professional" with experience

  3. Holography through optically active windows

    Science.gov (United States)

    Decker, A. J.

    1979-01-01

    By using two orthogonally polarized reference beams, holograms can be recorded through stressed windows and the reconstructed virtual image will show no stress pattern. As shown analytically, the stress-pattern-free hologram is recordable for any polarization state of the object illumination. Hence, the more efficient nondepolarizing diffuser can be used in performing holography through stressed windows if two reference beams are used. Results are presented for a pair of machined polysulfone windows intended for use in a holographic flow-visualization setup in a single-stage-compressor test rig.

  4. Designing for Virtual Windows in a Deep Space Habitat

    Science.gov (United States)

    Howe, A. Scott; Howard, Robert L.; Moore, Nathan; Amoroso, Michael

    2013-01-01

    This paper discusses configurations and test analogs toward the design of a virtual window capability in a Deep Space Habitat. Long-duration space missions will require crews to remain in the confines of a spacecraft for extended periods of time, with possible harmful effects if a crewmember cannot cope with the small habitable volume. Virtual windows expand perceived volume using a minimal amount of image projection equipment and computing resources, and allow a limited immersion in remote environments. Uses for the virtual window include: live or augmented reality views of the external environment; flight deck, piloting, observation, or other participation in remote missions through live transmission of cameras mounted to remote vehicles; pre-recorded background views of nature areas, seasonal occurrences, or cultural events; and pre-recorded events such as birthdays, anniversaries, and other meaningful events prepared by ground support and families of the crewmembers.

  5. Grab Windows training opportunities; check CERN Windows roadmap!

    CERN Multimedia

    IT Department

    2011-01-01

    CERN Operating Systems and Information Services group (IT-OIS) actively monitors market trends to check how new software products correspond to CERN needs. In the Windows world, Windows 7 has been a big hit, with over 1500 Windows 7 PCs within less than a year since its support was introduced at CERN. No wonder: Windows XP is nearly 10 years old and is steadily approaching the end of its life-cycle. At CERN, support for Windows XP will stop at the end of December 2012. Compared to Vista, Windows 7 has the same basic hardware requirements, but offers higher performance, so the decision to upgrade is rather straightforward. CERN support for Vista will end in June 2011. In the world of Microsoft Office, version 2007 offers better integration with the central services than the older version 2003. Progressive upgrade from 2003 to 2007 is planned to finish in September 2011, but users are encouraged to pro-actively upgrade at their convenience. Please note that Office 2007 brings an important change in the area of ...

  6. Tenants' experiences and satisfaction in social housing subject to comprehensive retrofitting

    DEFF Research Database (Denmark)

    Knudsen, Henrik Nellemose; Thomsen, Kirsten Engelund; Rose, Jørgen

    This report describes a Danish retrofitting project with focus on reducing the energy consump-tion in social housing. The objective of the project was to study tenants’ overall satisfaction with how the retrofitting of their dwellings was carried out and their experiences and satisfaction...

  7. Retrofitting a 1960s Split-Level, Cold-Climate Home

    Energy Technology Data Exchange (ETDEWEB)

    Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-07-01

    National programs such as Home Performance with ENERGY STAR® and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usage in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions. A key is to be non-intrusive with the efficiency measures so the retrofit projects can be accomplished in occupied homes. This cold climate retrofit project involved the design and optimization of a home in Connecticut that sought to improve energy savings by at least 30% (excluding solar PV) over the existing home's performance. This report documents the successful implementation of a cost-effective solution package that achieved performance greater than 30% over the pre-retrofit - what worked, what did not, and what improvements could be made.

  8. Sonoma House: Monitoring of the First U.S. Passive House Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    German, A.; Weitzel, B.; Backman, C.; Hoeschele, M.; Dakin, B.

    2012-12-01

    The Sonoma Deep Retrofit is a single-story deep retrofit project in the marine climate of Sonoma, California. The design was guided by Passive House principles which promote the use of very high levels of wall, ceiling, and floor insulation along with tight envelope construction to maintain a comfortable indoor environment with little or no need for conventional heating or cooling.

  9. Sonoma House. Monitoring of the First U.S. Passive House Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Weitzel, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2012-12-01

    The Sonoma Deep Retrofit is a single-story deep retrofit project in the marine climate of Sonoma, California. The design was guided by Passive House principles that promote the use of very high levels of wall, ceiling, and floor insulation along with tight envelope construction to maintain a comfortable indoor environment with little or no need for conventional heating or cooling.

  10. Retrofitting of homes for people in fuel poverty: Approach based on household thermal comfort

    International Nuclear Information System (INIS)

    Vilches, Alberto; Barrios Padura, Ángela; Molina Huelva, Marta

    2017-01-01

    In a context of fuel poverty, the application of cost-effective methodology for energy retrofitting of buildings is ineffective. In these situations, there is no energy consumption reduction and thermal comfort is hardly achieved. This paper introduces a methodology to choose the most appropriate retrofit measure in a context of fuel poverty. This methodology is based on thermal comfort as the main criterion, and secondarily, it is based on the budget for paying monthly energy bills and initial costs. This study demonstrates how thermal comfort and monthly available income of households must be the first criterion for decision-making process. The methodology has been applied in four buildings. Results demonstrate why active retrofit measures are ineffective when monthly budget to pay energy bills is reduced. In conclusion, recommendations are made to promote efficient public policies in energy retrofit. The study was supported by the European Regional Development Fund (ERDF) and carried out within the research project ‘{Re} Programa. (Re)habitation +(Re)generation +(Re)programming’ during 2013–2015. - Highlights: • A methodology is proposed for energy retrofit in a fuel poverty context. • Householder's monthly budget determines the energy retrofit effectiveness. • The cost-effective methodology is not applicable in a fuel poverty context. • Energy retrofit does not reduce energy consumption in a fuel poverty context. • Energy retrofit does not produce monthly monetary savings in a fuel poverty context.

  11. 40 CFR 1043.50 - Approval of methods to meet Tier 1 retrofit NOX standards.

    Science.gov (United States)

    2010-07-01

    ... retrofit NOX standards. 1043.50 Section 1043.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF NOX, SOX, AND PM EMISSIONS FROM MARINE ENGINES AND VESSELS SUBJECT TO THE MARPOL PROTOCOL § 1043.50 Approval of methods to meet Tier 1 retrofit NOX standards...

  12. Field testing of a low-cost retrofit filter berm to treat stormwater runoff contaminants.

    Science.gov (United States)

    2008-09-01

    The goal of this cooperative effort between MaineDOT and the University of New Hampshire was to test a low-cost : retrofit filter berm that would reduce non-point pollution from highway runoff. The retrofit berm would be easy to : construct using rea...

  13. Seismic Behavior of Substandard RC Columns Retrofitted with Embedded Aramid Fiber Reinforced Polymer (AFRP Reinforcement

    Directory of Open Access Journals (Sweden)

    Engin C. Seyhan

    2015-12-01

    Full Text Available Many existing reinforced concrete structures were constructed with substandard characteristics. Low quality concrete, poor transverse reinforcement details and insufficient flexural strength are among the most common deficiencies. While substandard structures are in need of retrofitting, particularly in seismic areas, problems such as high costs and disturbance to occupants are major obstacles for retrofit interventions. Fiber reinforced polymers can provide feasible retrofit solutions with minimum disturbance to occupants. In this study, the basic aim is to investigate the flexural seismic performance of substandard reinforced concrete columns retrofitted with embedded longitudinal fiber reinforced polymer reinforcement without increasing the original dimensions of the columns. In the experimental study, the reference and retrofitted columns were tested under constant vertical and reversed cyclic lateral loads. Three different connection methods of aramid fiber reinforced polymer reinforcement to the footing were investigated experimentally. A significant enhancement was obtained in lateral flexural strength through the proposed retrofitting method. Furthermore, it was observed that the cyclic lateral drift capacities of the retrofitted columns were as high as 3%, which can be deemed as quite satisfactory against seismic actions. The comparison of the experimental data with analytical calculations revealed that a conventional design approach assuming composite action between concrete and fiber reinforced polymer reinforcement can be used for flexural retrofit design. Experimental results also demonstrated that strain limit for longitudinal fiber reinforced polymer (FRP reinforcement should be remarkably lower in case of reversed cyclic loading conditions.

  14. 77 FR 51619 - Source Specific Federal Implementation Plan for Implementing Best Available Retrofit Technology...

    Science.gov (United States)

    2012-08-24

    ... Source Specific Federal Implementation Plan for Implementing Best Available Retrofit Technology for Four... Available Retrofit Technology for Four Corners Power Plant: Navajo Nation AGENCY: Environmental Protection...-fired power plant located on the Navajo Nation near Farmington, New Mexico, to achieve emissions...

  15. 75 FR 69373 - Source Specific Federal Implementation Plan for Implementing Best Available Retrofit Technology...

    Science.gov (United States)

    2010-11-12

    ... Federal Implementation Plan for Implementing Best Available Retrofit Technology for Four Corners Power... Available Retrofit Technology (BART) provision. The proposal was published in the Federal Register on... open houses and public hearings will occur in Shiprock, New Mexico on December 7, 2010, Farmington, New...

  16. Retrofitting Vegas: Implementing Energy Efficiency in Two Las Vegas Test Homes

    Energy Technology Data Exchange (ETDEWEB)

    Puttagunta, S.

    2013-04-01

    In 2009, the state of Nevada received nearly forty million dollars in Neighborhood Stabilization Funds from the Department of Housing and Urban Development. The purpose of this funding was to stabilize communities that have suffered from foreclosures and abandonment. In an effort to provide guidance to local officials and maximize how effectively this NSP funding is utilized in retrofitting homes, CARB provided design specifications, energy modeling, and technical support for the Building America Retrofit Alliance (BARA) team and its local partners - Better Building Performance, Nevada Energy Star Partners Green Alliance, and Home Free Nevada - for two retrofit test homes. One home was to demonstrate a modest retrofit and the other a deep energy retrofit. Through this project, CARB has provided two robust solution packages for retrofitting homes built in this region between the 1980s and early 1990s without substantially inconveniencing the occupants. The two test homes, the Carmen and Sierra Hills, demonstrate how cost-effectively energy efficient upgrades can be implemented in the hot, dry climate of the Southwest. In addition, the homes were used as an educational experience for home performance professionals, building trades, remodelers, and the general public. In-field trainings on air-sealing, HVAC upgrades, and insulating were provided to local contractors during the retrofit and BARA documented these retrofits through a series of video presentations, beginning with a site survey and concluding with the finished remodel and test out.

  17. Economic Decision-Making for Coal Power Flexibility Retrofitting and Compensation in China

    Directory of Open Access Journals (Sweden)

    Chunning Na

    2018-01-01

    Full Text Available In China, in order to integrate more renewable energy into the power grid, coal power flexibility retrofitting is imperative. This paper elaborates a generic method for estimating the flexibility potential from the rapid ramp rate and peak shaving operation using nonlinear programming, and defines three flexibility elastic coefficients to quantify the retrofitted targets. The optimized range of the retrofitted targets determined by the flexibility elastic coefficients have a reference significance on coal power flexibility retrofitting. Then, in order to enable economic decisions for coal power flexibility retrofitting, we address a profit maximizing issue regarding optimization decisions for coal power flexibility retrofitting under an assumption of perfect competition, further analyzing the characteristic roots of marginal cost equal to marginal revenue. The rationality of current compensation standards for peak shaving in China can also be judged in the analysis. The case study results show that economic decision-making depends on the compensation standard and the peak shaving depth and time. At a certain peak shaving depth and time, with rational compensation standard power plants are willing to carry out coal power flexibility retrofitting. The current compensation standard in Northeast China is high enough to carry out coal power flexibility retrofitting. These research conclusions have theoretical significance for China’s peak shaving compensation standards formulation.

  18. Expert Meeting Report. Interior Insulation Retrofit of Mass Masonry Wall Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Somerville, MA (United States); Van Straaten, R. [Building Science Corporation, Somerville, MA (United States)

    2012-02-01

    The Building Science Consortium held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011, at the Westford Regency Hotel in Westford, MA. This report outlines the extensive information that was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks.

  19. Expert Meeting Report: Interior Insulation Retrofit of Mass Masonry Wall Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Van Straaten, R.

    2012-02-01

    The Building Science Consortium held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011 at the Westford Regency Hotel in Westford, MA. This report outlines the extensive information that was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks.

  20. Designing trust: how strategic intermediaries choreograph homeowners’ low-carbon retrofit experience

    NARCIS (Netherlands)

    Wilde, de M.; Spaargaren, G.

    2018-01-01

    In the Netherlands, as in other European countries, the uncertain, fragmented character of the low-carbon retrofit market hampers a transition towards sustainable housing. Connecting homeowners to supply-side actors of low-carbon retrofit procedures, products and technologies in ways satisfactory to

  1. Review of retrofit strategies decision system in historic perspective

    Directory of Open Access Journals (Sweden)

    M. D. Bostenaru Dan

    2004-01-01

    Full Text Available Urban development is a process. In structuring and developing its phases different actors are implied, who act under different, sometimes opposite, dynamic conditions and within different reference systems. This paper aims to explore the contribution of participatism to disaster mitigation, when this concerns earthquake impact on urban settlements, through the support provided to multi-criteria decision in matters of retrofit. The research broadness in field of decision making on one side and the lack of a specific model for the retrofit of existing buildings on another side led to an extensive review of the state of the art in related models to address the issue. Core idea in the selection of existing models has been the preoccupation for collaborative issues, in other words, the consideration for the different actors implied in the planning process. The historic perspective on participative planning models is made from the view of two generations of citizen implication. The first approaches focus on the participation of the building owner/inhabitant in the planning process of building construction. As current strategies building rehabilitation and selection from alternative retrofit strategies are presented. New developments include innovative models using the internet or spatial databases. The investigated participation approaches show, that participation and communication as a more comprehensive term are an old topic in the field politics-democratisation-urbanism. In all cases it can be talked of 'successful learning processes', of the improvement of the level of the professional debate. More than 30 years history of participation marked a transition in understanding the concept: from participation, based on a central decision process leading to a solution controlled and steered by the political-administrative system, to communication, characterised by simultaneous decision processes taking place outside politics and administration in co

  2. Tank monitor and control system (TMACS) software configuration management plan

    International Nuclear Information System (INIS)

    GLASSCOCK, J.A.

    1999-01-01

    This Software Configuration Management Plan (SCMP) describes the methodology for control of computer software developed and supported by the Systems Development and Integration (SD and I) organization of Lockheed Martin Services, Inc. (LMSI) for the Tank Monitor and Control System (TMACS). This plan controls changes to the software and configuration files used by TMACS. The controlled software includes the Gensym software package, Gensym knowledge base files developed for TMACS, C-language programs used by TMACS, the operating system on the production machine, language compilers, and all Windows NT commands and functions which affect the operating environment. The configuration files controlled include the files downloaded to the Acromag and Westronic field instruments

  3. Infrared monitoring of gyrotron windows

    International Nuclear Information System (INIS)

    Huey, H.; Lopez, N.; Hu, G.; Choi, E.; Mundie, L.

    1983-01-01

    A technique for monitoring the gyrotron output window surface temperature with an infrared camera while the gyrotron is in operation has been developed. The IR camera views the window through a perforated waveguide wall, and serves both as a guide for the safe operation at high average power of the tube, as well as an aid in the analysis of new window designs. Window temperatures were studied as a function of a number of parameters, including gun anode voltage, beam current, magnetic field, coolant flow, and load matching. The IR technique is applicable to many types of high average power microwave and millimeter wave tubes. Successful operation of the Varian 60 GHz gyrotron to 214 kW CW was guided by the infrared camera. Analyses on 28, 56 and 60 GHz gyrotrons have led to a number of design changes. A comparison with computer calculations is also presented

  4. Configuration by Modularisation

    DEFF Research Database (Denmark)

    Riitahuhta, Asko; Andreasen, Mogens Myrup

    1998-01-01

    Globally operating companies have realized that locally customized products and services are today the prerequisite for the success. The capability or the paradigm to act locally in global markets is called Mass Customization [Victor 1997]. The prerequisite for Mass Customization is Configuration...... Management and i Configuration Management the most important means is Modularisation.The goal of this paper is to show Configuration Management as a contribution to the Mass Customisation and Modularisation as a contribution to the industrialisation of the design area [Andreasen 1997]. A basic model...

  5. Global Value Chain Configuration

    DEFF Research Database (Denmark)

    Hernandez, Virginia; Pedersen, Torben

    2017-01-01

    This paper reviews the literature on global value chain configuration, providing an overview of this topic. Specifically, we review the literature focusing on the concept of the global value chain and its activities, the decisions involved in its configuration, such as location, the governance...... modes chosen and the different ways of coordinating them. We also examine the outcomes of a global value chain configuration in terms of performance and upgrading. Our aim is to review the state of the art of these issues, identify research gaps and suggest new lines for future research that would...

  6. Retrofit concept for small safety related stationary machines

    Science.gov (United States)

    Epple, S.; Jalba, C. K.; Muminovic, A.; Jung, R.

    2017-05-01

    More and more old machines have the problem that their control electronics’ lifecycle comes to its intended end of life, whilst the mechanics itself and process capability is still in very good condition. This article shows an example of a reactive ion etcher originally built in 1988, which was refitted with a new control concept. The original control unit was repaired several times based on manufacturer’s obsolescence management. At start of the retrofit project the integrated circuits were no longer available for further repair of the original control unit. Safety, repeatability and stability of the process were greatly improved.

  7. Use of digital photography for power plant retrofits

    International Nuclear Information System (INIS)

    Kamba, J.J.

    1995-01-01

    One of the latest advancements in electronic tools for reducing engineering and drafting effort is the use of digital photography (DP) for retrofit and betterment projects at fossil and nuclear power plants. Sargent and Lundy (S and L) has effectively used digital photography for condition assessments, minor backfit repairs, thermo-lag fire wrap assessments and repairs, and other applications. Digital photography offers several benefits on these types of projects including eliminating the need for official repair drawings and providing station maintenance with a true 3-D visualization of the repair

  8. Newporter Apartments. Deep Energy Retrofit Short Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, Andrew [BA-PIRC, Cocoa, FL (United States); Howard, Luke [BA-PIRC, Cocoa, FL (United States); Kunkle, Rick [BA-PIRC, Cocoa, FL (United States); Lubliner, Michael [BA-PIRC, Cocoa, FL (United States); Auer, Dan [BA-PIRC, Cocoa, FL (United States); Clegg, Zach [BA-PIRC, Cocoa, FL (United States)

    2012-12-01

    This project demonstrates a path to meet the goal of the Building America program to reduce home energy use by 30% in multi-family buildings. The project demonstrates cost-effective energy savings targets as well as improved comfort and indoor environmental quality (IEQ) associated with deep energy retrofits by a large public housing authority as part of a larger rehabilitation effort. The project focuses on a typical 1960’s vintage low-rise multi-family apartment community (120 units in three buildings).

  9. Newporter Apartments: Deep Energy Retrofit Short-Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, A.; Howard, L.; Kunkle, R.; Lubliner, M.; Auer, D.; Clegg, Z.

    2012-12-01

    This project demonstrates a path to meet the goal of the Building America program to reduce home energy use by 30% in multi-family buildings. The project demonstrates cost effective energy savings targets as well as improved comfort and indoor environmental quality (IEQ) associated with deep energy retrofits by a large public housing authority as part of a larger rehabilitation effort. The project focuses on a typical 1960's vintage low-rise multi-family apartment community (120 units in three buildings).

  10. Results from Development of Model Specifications for Multifamily Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Brozyna, K.

    2012-08-01

    Specifications, modeled after CSI MasterFormat, provide the trade contractors and builders with requirements and recommendations on specific building materials, components and industry practices that comply with the expectations and intent of the requirements within the various funding programs associated with a project. The goal is to create a greater level of consistency in execution of energy efficiency retrofits measures across the multiple regions a developer may work. IBACOS and Mercy Housing developed sample model specifications based on a common building construction type that Mercy Housing encounters.

  11. Results From Development of Model Specifications for Multifamily Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Brozyna, Kevin [IBACOS, Inc., Pittsburgh, PA (United States)

    2012-08-01

    Specifications, modeled after CSI MasterFormat, provide the trade contractors and builders with requirements and recommendations on specific building materials, components and industry practices that comply with the expectations and intent of the requirements within the various funding programs associated with a project. The goal is to create a greater level of consistency in execution of energy efficiency retrofits measures across the multiple regions a developer may work. IBACOS and Mercy Housing developed sample model specifications based on a common building construction type that Mercy Housing encounters.

  12. Indoor climate perceived as improved after energy retrofitting of single-family houses

    DEFF Research Database (Denmark)

    Knudsen, Henrik Nellemose; Jensen, Ole Michael

    2014-01-01

    . It was found that energy consumption and indoor climate are ever more in focus when buying a house and important drivers for house owners’ motivation for retrofitting their existing house. Energy retrofitting is complicated and it is also experienced as such by many house owners. There is uncertainty......The need for energy retrofitting of the Danish single-family houses is massive, especially for the high proportion of single-family houses built in the 1960s and 1970s. But even though the potential benefits are many, only few families embark on a major energy retrofit. There may be many reasons...... for this. An obvious one may be limited knowledge of non-energy benefits, e.g. in relation to the indoor climate. The objective of this study was to explain this limited effort to save energy by identifying barriers and incentives among house owners in relation to energy retrofitting of one’s own house...

  13. The Life Cycle CO2 (LCCO2 Evaluation of Retrofits for Water-Saving Fittings

    Directory of Open Access Journals (Sweden)

    Yasutoshi Shimizu

    2013-05-01

    Full Text Available As part of measures being taken against global warming, the reduction of CO2 emissions by retrofitting for water-saving fittings in homes is spreading throughout the world. However, although this retrofitting reduces the environmental impact at the use stage, it generates new impacts at the production and disposal stages. In addition, there has been little research that discusses the reduction in environmental impact obtained by retrofitting from the viewpoint of the overall life cycle of such fittings. In this paper, an evaluation of the environmental impact of retrofitting in terms of the entire life cycle was carried out for toilet bowls and showerheads. The findings show that even for a toilet bowl that generates a large environmental load at the production stage, there is no overall increase in the environmental impact by retrofitting for the average usable life of 20 years.

  14. Measured Cooling Performance and Potential for Buried Duct Condensation in a 1991 Central Florida Retrofit Home

    Energy Technology Data Exchange (ETDEWEB)

    Chasar, Dave [Building America Partership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Withers, Charles R. [Building America Partership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2013-02-01

    FSEC conducted energy performance monitoring of two existing residences in Central Florida that were undergoing various retrofits. These homes were occupied by FSEC researchers and were fully instrumented to provide detailed energy, temperature, and humidity measurements. The data provided feedback about the performance of two levels of retrofit in two types of homes in a hot-humid climate. This report covers a moderate-level retrofit and includes two years of pre-retrofit data to characterize the impact of improvements. The other home is a 'deep energy retrofit' (detailed in a separate report) that has performed at near zero energy with a photovoltaic (PV) system and extensive envelope improvements.

  15. Retrofitting Las Vegas. Implementing Energy Efficiency in Two Las Vegas Test Homes

    Energy Technology Data Exchange (ETDEWEB)

    Puttagunta, S. [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2013-04-01

    In 2009, the state of Nevada received nearly $40 million in Neighborhood Stabilization Funds from the Department of Housing and Urban Development to use to stabilize communities that have suffered from foreclosures and abandonment. In order to provide guidance to local officials and maximize how effectively this NSP funding is used in retrofitting homes, the CARB team provided design specifications, energy modeling, and technical support for the BARA team and its local partners—Better Building Performance, Nevada Energy Star Partners Green Alliance, and Home Free Nevada—for two retrofit test homes. One home demonstrated a modest retrofit and the other a deep energy retrofit. This report describes the retrofit packages, which were used as an educational experience for home performance professionals, building trades, remodelers, and the general public.

  16. Determinants of Household Water Conservation Retrofit Activity: A Discrete Choice Model Using Survey Data

    Science.gov (United States)

    Cameron, T. A.; Wright, M. B.

    1990-02-01

    Economic analyses of residential water demand have typically concentrated on price and income elasticities. In the short run a substantial change in water prices might induce only small changes in consumption levels. As time passes, however, households will have the opportunity to "retrofit" existing water-using equipment to make it less water-intensive. This produces medium- to long-run demand elasticities that are higher than short-run studies suggest. We examine responses to water conservation questions appearing on the Los Angeles Department of Water and Power's 1983 residential energy survey. We find that households' decisions to install shower retrofit devices are influenced by the potential to save money on water heating bills. We attribute toilet retrofit decisions more to noneconomic factors which might be characterized as "general conservation mindedness." The endogeneity of these retrofit decisions casts some doubt on the results of studies of individual households that treat voluntary retrofits as exogenous.

  17. A window on urban sustainability

    International Nuclear Information System (INIS)

    Stigt, Rien van; Driessen, Peter P.J.; Spit, Tejo J.M.

    2013-01-01

    Sustainable urban development requires the integration of environmental interests in urban planning. Although various methods of environmental assessment have been developed, plan outcomes are often disappointing due to the complex nature of decision-making in urban planning, which takes place in multiple arenas within multiple policy networks involving diverse stakeholders. We argue that the concept of ‘decision windows’ can structure this seemingly chaotic chain of interrelated decisions. First, explicitly considering the dynamics of the decision-making process, we further conceptualized decision windows as moments in an intricate web of substantively connected deliberative processes where issues are reframed within a decision-making arena, and interests may be linked within and across arenas. Adopting this perspective in two case studies, we then explored how decision windows arise, which factors determine their effectiveness and how their occurrence can be influenced so as to arrive at more sustainable solutions. We conclude that the integration of environmental interests in urban planning is highly dependent on the ability of the professionals involved to recognize and manipulate decision windows. Finally, we explore how decision windows may be opened. -- Highlights: • Decision-making about sustainable urban development occurs in networks. • The concept of ‘decision windows’ was further elaborated. • Decision windows help understand how environmental interests enter decision-making. • Decision windows can, to some extent, be influenced

  18. Mastering Microsoft Windows Server 2008 R2

    CERN Document Server

    Minasi, Mark; Finn, Aidan

    2010-01-01

    The one book you absolutely need to get up and running with Windows Server 2008 R2. One of the world's leading Windows authorities and top-selling author Mark Minasi explores every nook and cranny of the latest version of Microsoft's flagship network operating system, Windows Server 2008 R2, giving you the most in-depth coverage in any book on the market.: Focuses on Windows Windows Server 2008 R2, the newest version of Microsoft's Windows' server line of operating system, and the ideal server for new Windows 7 clients; Author Mark Minasi is one of the world's leading Windows authorities and h

  19. Drupal 8 configuration management

    CERN Document Server

    Borchert, Stefan

    2015-01-01

    Drupal 8 Configuration Management is intended for people who use Drupal 8 to build websites, whether you are a hobbyist using Drupal for the first time, a long-time Drupal site builder, or a professional web developer.

  20. Configuration Management Automation (CMA) -

    Data.gov (United States)

    Department of Transportation — Configuration Management Automation (CMA) will provide an automated, integrated enterprise solution to support CM of FAA NAS and Non-NAS assets and investments. CMA...

  1. Computer software configuration management

    International Nuclear Information System (INIS)

    Pelletier, G.

    1987-08-01

    This report reviews the basic elements of software configuration management (SCM) as defined by military and industry standards. Several software configuration management standards are evaluated given the requirements of the nuclear industry. A survey is included of available automated tools for supporting SCM activities. Some information is given on the experience of establishing and using SCM plans of other organizations that manage critical software. The report concludes with recommendations of practices that would be most appropriate for the nuclear power industry in Canada

  2. Exclusive queueing model including the choice of service windows

    Science.gov (United States)

    Tanaka, Masahiro; Yanagisawa, Daichi; Nishinari, Katsuhiro

    2018-01-01

    In a queueing system involving multiple service windows, choice behavior is a significant concern. This paper incorporates the choice of service windows into a queueing model with a floor represented by discrete cells. We contrived a logit-based choice algorithm for agents considering the numbers of agents and the distances to all service windows. Simulations were conducted with various parameters of agent choice preference for these two elements and for different floor configurations, including the floor length and the number of service windows. We investigated the model from the viewpoint of transit times and entrance block rates. The influences of the parameters on these factors were surveyed in detail and we determined that there are optimum floor lengths that minimize the transit times. In addition, we observed that the transit times were determined almost entirely by the entrance block rates. The results of the presented model are relevant to understanding queueing systems including the choice of service windows and can be employed to optimize facility design and floor management.

  3. Deep Energy Retrofit Guidance for the Building America Solutions Center

    Energy Technology Data Exchange (ETDEWEB)

    Less, Brennan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-01-01

    The U.S. DOE Building America program has established a research agenda targeting market-relevant strategies to achieve 40% reductions in existing home energy use by 2030. Deep Energy Retrofits (DERs) are part of the strategy to meet and exceed this goal. DERs are projects that create new, valuable assets from existing residences, by bringing homes into alignment with the expectations of the 21st century. Ideally, high energy using, dated homes that are failing to provide adequate modern services to their owners and occupants (e.g., comfortable temperatures, acceptable humidity, clean, healthy), are transformed through comprehensive upgrades to the building envelope, services and miscellaneous loads into next generation high performance homes. These guidance documents provide information to aid in the broader market adoption of DERs. They are intended for inclusion in the online resource the Building America Solutions Center (BASC). This document is an assemblage of multiple entries in the BASC, each of which addresses a specific aspect of Deep Energy Retrofit best practices for projects targeting at least 50% energy reductions. The contents are based upon a review of actual DERs in the U.S., as well as a mixture of engineering judgment, published guidance from DOE research in technologies and DERs, simulations of cost-optimal DERs, Energy Star and Consortium for Energy Efficiency (CEE) product criteria, and energy codes.

  4. High Performance Slab-on-Grade Foundation Insulation Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR, St. Paul, MN (United States); Mosiman, Garrett E. [NorthernSTAR, St. Paul, MN (United States)

    2015-09-01

    ?A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulation at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated). The optimum insulation strategy was applied to single and multi-family residential buildings in climate zone 4 - 7. The highest site energy savings of 5% was realized for a single family home in Duluth, MN, and the lowest savings of 1.4 % for a 4-unit townhouse in Richmond, VA. SOG foundation insulation retrofit simple paybacks ranged from 18 to 47 years. There are other benefits of SOG foundation insulation resulting from the increase in the slab surface temperatures. These include increased occupant thermal comfort, and a decrease in slab surface condensation particularly around the slab perimeter.

  5. Retrofit of ammonia plant for improving energy efficiency

    International Nuclear Information System (INIS)

    Panjeshahi, M.H.; Ghasemian Langeroudi, E.; Tahouni, N.

    2008-01-01

    The aim of this work is to perform a retrofit study of an ammonia plant, in purpose of improving energy efficiency. As a common practice, one can divide an ammonia plant into two parts: the hot-end and the cold-end. In the hot section, two different options are investigated that both lead to a threshold condition and achieve maximum energy saving. The first option covers only process-to-process energy integration, while the second option considers some modification in the convection section of the primary reformer through a new arrangement of the heating coils. Thus, a considerable reduction in cooling water, HP steam and fuel gas consumption is achieved. In the cold section, retrofit study is dominated by reducing the amount of shaft work or power consumption in the refrigeration system. Application of the Combined Pinch and Exergy Analysis revealed that part of the shaft work, which was originally being used, was inefficient and could have been avoided in a well-integrated design. Therefore, by proposing optimum refrigeration levels, reasonable saving (15%) in power consumption was observed without the need for new investment

  6. Retrofitted green roofs and walls and improvements in thermal comfort

    Science.gov (United States)

    Feitosa, Renato Castiglia; Wilkinson, Sara

    2017-06-01

    Increased urbanization has led to a worsening in the quality of life for many people living in large cities in respect of the urban heat island effect and increases of indoor temperatures in housing and other buildings. A solution may be to retrofit existing environments to their former conditions, with a combination of green infrastructures applied to existing walls and rooftops. Retrofitted green roofs may attenuate housing temperature. However, with tall buildings, facade areas are much larger compared to rooftop areas, the role of green walls in mitigating extreme temperatures is more pronounced. Thus, the combination of green roofs and green walls is expected to promote a better thermal performance in the building envelope. For this purpose, a modular vegetated system is adopted for covering both walls and rooftops. Rather than temperature itself, the heat index, which comprises the combined effect of temperature and relative humidity is used in the evaluation of thermal comfort in small scale experiments performed in Sydney - Australia, where identical timber framed structures prototypes (vegetated and non-vegetated) are compared. The results have shown a different understanding of thermal comfort improvement regarding heat index rather than temperature itself. The combination of green roof and walls has a valid role to play in heat index attenuation.

  7. Behavioral study of cnc-retrofitting kits for lathe machine

    International Nuclear Information System (INIS)

    Ahmad, I.

    1999-01-01

    The aim of this project is to develop a Computerized Numerical Controlled (CNC) retrofitting kit for a lathe machine, study its behavior and compare its performance with the retrofitting kit already designed and fabricated at (Pakistan Institute of Engineering and Applied Sciences (PIEAS). Design calculations were performed assuming 100 mm work piece diameter and 800 mm length of stock using tool materials HSS, uncoated carbide, coated carbide, ceramic and cermet tools for different materials. Also cutting, thrust and radial forces on a single point cutting tool were determined. Stepper motors of torque 972 oz-in were selected to drive the carriage and cross-slide in Z and X-directions respectively. Power screws were replaced with ball screws of 0.63 inch dia. (x-direction) and 1.26 in. dia. (Z-direction) which were locally manufactured in the workshop. Deep groove and Angular contact ball bearings were used to support the ball screw shafts against axial and radial loads. Flexible and plain couplings were developed to couple encoders and motors to the ball screw shafts respectively. Panel mount optical rotary encoders are being used for feedback control. Mechanical assembly is complete but due to unavailability of wiring diagram for motors, control electronics could not be accomplished. Therefore, machine could not be evaluated in terms of accuracy, repeatability and resolution using computer software. (author)

  8. Assessment of retrofit automatic vent dampers for residential heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, D.L.; Wilson, R.P. Jr.; Ashley, L.E.; Butterfield, J.F.

    1977-11-01

    Automatic vent dampers are devices installed in the exhaust vent of a central heating system which prohibit the chimney flow of warm air from the dwelling space and from within the furnace when the heating system is not operating. An investigation of the effect of thermally actuated or electrically actuated dampers on home energy conservation, their cost, and safety is described. Eleven heating system types in 2 geographic regions were used in this study. It was determined that good quality, safe electrically actuated dampers are available in the U.S. and that thermally actuated units will be available soon; an average savings of approximately 8% in home heating cost could be achieved by using automatic dampers with suitable furnace systems in regions with a heating season of more than 4000 degree-days; the cost of the automatic dampers is from $65 to $140 with a payback period of 3 to 4 1/2 y; and, with the average heating system, vent damper retrofit alone is not as an attractive energy conservation option as combined vent damper, intermittent ignition device retrofit, and reduced gas orifice. (LCL)

  9. Analysis of institutional mechanisms affecting residential and commercial buildings retrofit

    Energy Technology Data Exchange (ETDEWEB)

    1980-09-01

    Barriers to energy conservation in the residential and commercial sectors influence (1) the willingness of building occupants to modify their energy usage habits, and (2) the willingness of building owners/occupants to upgrade the thermal characteristics of the structures within which they live or work and the appliances which they use. The barriers that influence the willingness of building owners/occupants to modify the thermal efficiency characteristics of building structures and heating/cooling systems are discussed. This focus is further narrowed to include only those barriers that impede modifications to existing buildings, i.e., energy conservation retrofit activity. Eight barriers selected for their suitability for Federal action in the residential and commercial sectors and examined are: fuel pricing policies that in the short term do not provide enough incentive to invest in energy conservation; high finance cost; inability to evaluate contractor performance; inability to evaluate retrofit products; lack of well-integrated or one-stop marketing systems (referred to as lack of delivery systems); lack of precise or customized information; lack of sociological/psychological incentives; and use of the first-cost decision criterion (expanded to include short-term payback criterion for the commercial sector). The impacts of these barriers on energy conservation are separately assessed for the residential and commercial sectors.

  10. Turtle origins: insights from phylogenetic retrofitting and molecular scaffolds.

    Science.gov (United States)

    Lee, M S Y

    2013-12-01

    Adding new taxa to morphological phylogenetic analyses without substantially revising the set of included characters is a common practice, with drawbacks (undersampling of relevant characters) and potential benefits (character selection is not biased by preconceptions over the affinities of the 'retrofitted' taxon). Retrofitting turtles (Testudines) and other taxa to recent reptile phylogenies consistently places turtles with anapsid-grade parareptiles (especially Eunotosaurus and/or pareiasauromorphs), under both Bayesian and parsimony analyses. This morphological evidence for turtle-parareptile affinities appears to contradict the robust genomic evidence that extant (living) turtles are nested within diapsids as sister to extant archosaurs (birds and crocodilians). However, the morphological data are almost equally consistent with a turtle-archosaur clade: enforcing this molecular scaffold onto the morphological data does not greatly increase tree length (parsimony) or reduce likelihood (Bayesian inference). Moreover, under certain analytic conditions, Eunotosaurus groups with turtles and thus also falls within the turtle-archosaur clade. This result raises the possibility that turtles could simultaneously be most closely related to a taxon traditionally considered a parareptile (Eunotosaurus) and still have archosaurs as their closest extant sister group. © 2013 The Author. Journal of Evolutionary Biology © 2013 European Society For Evolutionary Biology.

  11. Switchable Materials for Smart Windows.

    Science.gov (United States)

    Wang, Yang; Runnerstrom, Evan L; Milliron, Delia J

    2016-06-07

    This article reviews the basic principles of and recent developments in electrochromic, photochromic, and thermochromic materials for applications in smart windows. Compared with current static windows, smart windows can dynamically modulate the transmittance of solar irradiation based on weather conditions and personal preferences, thus simultaneously improving building energy efficiency and indoor human comfort. Although some smart windows are commercially available, their widespread implementation has not yet been realized. Recent advances in nanostructured materials provide new opportunities for next-generation smart window technology owing to their unique structure-property relations. Nanomaterials can provide enhanced coloration efficiency, faster switching kinetics, and longer lifetime. In addition, their compatibility with solution processing enables low-cost and high-throughput fabrication. This review also discusses the importance of dual-band modulation of visible and near-infrared (NIR) light, as nearly 50% of solar energy lies in the NIR region. Some latest results show that solution-processable nanostructured systems can selectively modulate the NIR light without affecting the visible transmittance, thus reducing energy consumption by air conditioning, heating, and artificial lighting.

  12. 16 CFR 455.3 - Window form.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Window form. 455.3 Section 455.3 Commercial... Window form. (a) Form given to buyer. Give the buyer of a used vehicle sold by you the window form...) Incorporated into contract. The information on the final version of the window form is incorporated into the...

  13. Music@Microsoft.Windows: Composing Ambience

    Science.gov (United States)

    Rickert, Thomas

    2010-01-01

    It is well known, of course, that all Windows versions except for 3.1 have a brief (four to six second) piece of music indicating that Windows is booted and ready for use. While the music may indicate Windows has booted, it bears no immediately discernable relation to the various uses we might actually put Windows to--working, gaming,…

  14. Windows Server 2012 R2 administrator cookbook

    CERN Document Server

    Krause, Jordan

    2015-01-01

    This book is intended for system administrators and IT professionals with experience in Windows Server 2008 or Windows Server 2012 environments who are looking to acquire the skills and knowledge necessary to manage and maintain the core infrastructure required for a Windows Server 2012 and Windows Server 2012 R2 environment.

  15. Travailler avec Windows 7 au CERN (FR)

    CERN Multimedia

    CERN. Geneva

    2010-01-01

    Vue d'ensemble des nouveaux concepts et des changements dans l'interface utilisateur survenus dans Windows 7 depuis les versions antérieures de Windows (XP ou Vista). La mise à disposition de Windows 7 au CERN et son intégration dans l’infrastructure de Windows au CERN seront présentées.

  16. Retrofitting the Low Impact Development Practices into Developed Urban areas Including Barriers and Potential Solution

    Science.gov (United States)

    Shafique, Muhammad; Kim, Reeho

    2017-06-01

    Low impact development (LID)/green infrastructure (GI) practices have been identified as the sustainable practices of managing the stormwater in urban areas. Due to the increasing population, most of the cities are more developing which results in the change of natural area into impervious areas (roads, buildings etc.). Moreover, urbanization and climate change are causing many water-related problems and making over cities unsafe and insecure. Under these circumstances, there is a need to introduce new stormwater management practices into developed cities to reduce the adverse impacts of urbanization. For this purpose, retrofitting low impact development practices demands more attention to reduce these water-related problems and trying to make our cities sustainable. In developed areas, there is a little space is available for the retrofitting of LID practices for the stormwater management. Therefore, the selection of an appropriate place to retrofitting LID practices needs more concern. This paper describes the successfully applied retrofitting LID practices around the globe. It also includes the process of applying retrofitting LID practices at the suitable place with the suitable combination. Optimal places for the retrofitting of different LID practices are also mentioned. This paper also highlights the barriers and potential solutions of retrofitting LID practices in urban areas.

  17. Retrofitting a 1960s Split-Level, Cold-Climate Home

    Energy Technology Data Exchange (ETDEWEB)

    Puttagunta, Srikanth [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-07-13

    National programs such as Home Performance with ENERGY STAR® and numerous other utility air-sealing programs have made homeowners aware of the benefits of energy-efficiency retrofits. Yet these programs tend to focus only on the low-hanging fruit: they recommend air sealing the thermal envelope and ductwork where accessible, switching to efficient lighting and low-flow fixtures, and improving the efficiency of mechanical systems (though insufficient funds or lack of knowledge to implement these improvements commonly prevent the implementation of these higher cost upgrades). At the other end of the spectrum, various utilities across the country are encouraging deep energy retrofit programs. Although deep energy retrofits typically seek 50% energy savings, they are often quite costly and are most applicable to gut-rehab projects. A significant potential for lowering energy use in existing homes lies between the lowhanging fruit and deep energy retrofit approaches—retrofits that save approximately 30% in energy compared to the pre-retrofit conditions. The energy-efficiency measures need to be nonintrusive so the retrofit projects can be accomplished in occupied homes.

  18. Retrofitting the Low Impact Development Practices into Developed Urban areas Including Barriers and Potential Solution

    Directory of Open Access Journals (Sweden)

    Shafique Muhammad

    2017-06-01

    Full Text Available Low impact development (LID/green infrastructure (GI practices have been identified as the sustainable practices of managing the stormwater in urban areas. Due to the increasing population, most of the cities are more developing which results in the change of natural area into impervious areas (roads, buildings etc.. Moreover, urbanization and climate change are causing many water-related problems and making over cities unsafe and insecure. Under these circumstances, there is a need to introduce new stormwater management practices into developed cities to reduce the adverse impacts of urbanization. For this purpose, retrofitting low impact development practices demands more attention to reduce these water-related problems and trying to make our cities sustainable. In developed areas, there is a little space is available for the retrofitting of LID practices for the stormwater management. Therefore, the selection of an appropriate place to retrofitting LID practices needs more concern. This paper describes the successfully applied retrofitting LID practices around the globe. It also includes the process of applying retrofitting LID practices at the suitable place with the suitable combination. Optimal places for the retrofitting of different LID practices are also mentioned. This paper also highlights the barriers and potential solutions of retrofitting LID practices in urban areas.

  19. Life-Cycle Assessment of Seismic Retrofit Strategies Applied to Existing Building Structures

    Directory of Open Access Journals (Sweden)

    Umberto Vitiello

    2016-12-01

    Full Text Available In the last few years, the renovation and refurbishment of existing buildings have become the main activities of the construction industry. In particular, many studies have recently focused on the mechanical and energy performances of existing retrofitted/refurbished facilities, while some research has addressed the environmental effects of such operations. The present study aims to assess the environmental impact of some retrofit interventions on an existing reinforced concrete (RC building. Once the structural requirements have been satisfied and the environmental effects of these retrofit solutions defined, the final purpose of this study is to identify the most environmentally sustainable retrofit strategy. The environmental impact of the structural retrofit options is assessed using a life-cycle assessment (LCA. This paper sets out a systematic approach that can be adopted when choosing the best structural retrofit option in terms of sustainability performance. The final aim of the study is to also provide a tool for researchers and practitioners that reflects a deep understanding of the sustainability aspects of retrofit operations and can be used for future researches or practical activities.

  20. The LHCb configuration database

    CERN Document Server

    Abadie, L; Van Herwijnen, Eric; Jacobsson, R; Jost, B; Neufeld, N

    2005-01-01

    The aim of the LHCb configuration database is to store information about all the controllable devices of the detector. The experiment's control system (that uses PVSS ) will configure, start up and monitor the detector from the information in the configuration database. The database will contain devices with their properties, connectivity and hierarchy. The ability to store and rapidly retrieve huge amounts of data, and the navigability between devices are important requirements. We have collected use cases to ensure the completeness of the design. Using the entity relationship modelling technique we describe the use cases as classes with attributes and links. We designed the schema for the tables using relational diagrams. This methodology has been applied to the TFC (switches) and DAQ system. Other parts of the detector will follow later. The database has been implemented using Oracle to benefit from central CERN database support. The project also foresees the creation of tools to populate, maintain, and co...

  1. Configuration Control Office

    CERN Multimedia

    Beltramello, O

    In order to enable Technical Coordination to manage the detector configuration and to be aware of all changes in this configuration, a baseline of the envelopes has been created in April 2001. Fifteen system and multi-system envelope drawings have been approved and baselined. An EDMS file is associated with each approved envelope, which provides a list of the current known unsolved conflicts related to the envelope and a list of remaining drawing inconsistencies to be corrected. The envelope status with the associated drawings and EDMS file can be found on the web at this adress: http://atlasinfo.cern.ch/Atlas/TCOORD/Activities/Installation/Configuration/ Any modification in the baseline has to be requested via the Engineering Change Requests. The procedure can be found under: http://atlasinfo.cern.ch/Atlas/TCOORD/Activities/TcOffice/Quality/ECR/ TC will review all the systems envelopes in the near future and manage conflict resolution with the collaboration of the systems.

  2. Oscillatory integration windows in neurons

    Science.gov (United States)

    Gupta, Nitin; Singh, Swikriti Saran; Stopfer, Mark

    2016-01-01

    Oscillatory synchrony among neurons occurs in many species and brain areas, and has been proposed to help neural circuits process information. One hypothesis states that oscillatory input creates cyclic integration windows: specific times in each oscillatory cycle when postsynaptic neurons become especially responsive to inputs. With paired local field potential (LFP) and intracellular recordings and controlled stimulus manipulations we directly test this idea in the locust olfactory system. We find that inputs arriving in Kenyon cells (KCs) sum most effectively in a preferred window of the oscillation cycle. With a computational model, we show that the non-uniform structure of noise in the membrane potential helps mediate this process. Further experiments performed in vivo demonstrate that integration windows can form in the absence of inhibition and at a broad range of oscillation frequencies. Our results reveal how a fundamental coincidence-detection mechanism in a neural circuit functions to decode temporally organized spiking. PMID:27976720

  3. Teach yourself visually Windows 8

    CERN Document Server

    McFedries, Paul

    2012-01-01

    A practical guide for visual learners eager to get started with Windows 8 If you learn more quickly when you can see how things are done, this Visual guide is the easiest way to get up and running on Windows 8. It covers more than 150 essential Windows tasks, using full-color screen shots and step-by-step instructions to show you just what to do. Learn your way around the interface and how to install programs, set up user accounts, play music and other media files, download photos from your digital camera, go online, set up and secure an e-mail account, and much more. The tried-and-true format

  4. Windows Server 2012 : Uudet ominaisuudet ja muutokset

    OpenAIRE

    Oksanen, Joni

    2013-01-01

    Tämän opintyön tarkoituksena on valottaa Windows Server 2012 -käyttöjärjestelmän muutoksia verrattuna vanhaan Windows Server 2008 R2 -versioon. Työ aloitettiin ennen Windows Server 2012 -julkaisua Release Candidate -version testauksella ja myöhemmin julkaisun jälkeen Windows Serverin kokeiluversiolla. Työssä on silti ajankohtaista tietoa Windows Server 2012:sta. Aluksi käsitellään Windows Servereiden kehityskaarta lyhyesti ja käsitellään uusinta Windows Serveriä tuotteena se...

  5. Optimizing Whole House Deep Energy Retrofit Packages: A Case Study of Existing Chicago-Area Homes

    Directory of Open Access Journals (Sweden)

    Honnie Aguilar Leinartas

    2015-05-01

    Full Text Available Improving the energy efficiency of the residential building stock plays a key role in mitigating global climate change. New guidelines are targeting widespread application of deep energy retrofits to existing homes that reduce their annual energy use by 50%, but questions remain as to how to identify and prioritize the most cost-effective retrofit measures. This work demonstrates the utility of whole building energy simulation and optimization software to construct a “tool-box” of prescriptive deep energy retrofits that can be applied to large portions of the existing housing stock. We consider 10 generally representative typology groups of existing single-family detached homes built prior to 1978 in the Chicago area for identifying cost-optimal deep energy retrofit packages. Simulations were conducted in BEopt and EnergyPlus operating on a cloud-computing platform to first identify cost-optimal enclosure retrofits and then identify cost-optimal upgrades to heating, ventilation, and air-conditioning (HVAC systems. Results reveal that prescriptive retrofit packages achieving at least 50% site energy savings can be defined for most homes through a combination of envelope retrofits, lighting upgrades, and upgrades to existing HVAC system efficiency or conversion to mini-split heat pumps. The average upfront cost of retrofits is estimated to be ~$14,400, resulting in average annual site energy savings of ~54% and an average simple payback period of ~25 years. Widespread application of these prescriptive retrofit packages across the existing Chicago-area residential building stock is predicted to reduce annual site energy use by 3.7 × 1016 J and yield approximately $280 million USD in annual energy savings.

  6. Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community

    Energy Technology Data Exchange (ETDEWEB)

    Gates, C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Neuhauser, K. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-03-01

    Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent 'package' of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

  7. Windows 7 is supported at CERN

    CERN Multimedia

    IT Department

    2010-01-01

    The new version of the Windows operating system - Windows 7 - is now officially supported at CERN. Windows 7 32-bit is now the default operating system for the new computers at CERN. What’s new in Windows 7 Users of Windows XP will find many new features and options. Users of Windows Vista will feel very familiar with one major difference: higher performance and better responsiveness of the operating system. Other enhancements include: refined Aero desktop that makes it easier to navigate between your different application windows; new snapping windows that allows user to resize a window simply by dragging it to the edge of the screen and “pin” that allows grouping and arranging often accessed applications on the taskbar. Windows 7 introduces the new concept of libraries – containers for user files that have links to different local or network folders. By default, users can see four libraries: Documents, Music, Pictures and Videos. These libraries point to the cor...

  8. *New* CRITICAL Windows Security patch

    CERN Multimedia

    2003-01-01

    On 10 September 2003, Microsoft issued a new CRITICAL security patch, MS03-039. It must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security hole and patch for MS03-039 (which also includes MS03-026) are at: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp

  9. *New*: CRITICAL Windows Security patch

    CERN Multimedia

    2003-01-01

    On 10 September 2003, Microsoft issued a new CRITICAL security patch, MS03-039. It must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security hole and patch for MS03-039 (which also includes MS03-026) are at: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp

  10. Advanced Control of Electrochromic Windows

    OpenAIRE

    Scartezzini, Jean-Louis; Zarkadis, Nikos; Morel, Nicolas

    2013-01-01

    In our research we use the technology of electrochromic (EC) glazing to maximize the use of daylight and minimize the energy consumption in buildings while preserving visual and thermal comfort of the users. We propose an advanced automatic control of EC windows coupled with an anidolic daylighting system (ADS), blinds and dimmable fluorescent lights. EC windows with a visible transmittance range (Tv) of 0.15 – 0.50 were installed on the southern façade of an office room of the LESO experimen...

  11. What's New in Windows Vista?

    CERN Document Server

    Culp, Brian

    2006-01-01

    Get ready for a quick blast through this significant change to Windows! This guide will give you a quick look at many of the most significant new features in Vista, Microsoft's first revision of Windows in nearly six years. Starting with the changes to the interface, introducing Aero, and showing you some visuals, we then move on to the completely revamped search options. The new task scheduler and printing gadgets, are next with some cool new changes. Probably the most significant changes, however, come in the area of security and this guide takes a look at them from user priveleges, to

  12. SNS Proton Beam Window Disposal

    Directory of Open Access Journals (Sweden)

    Popova Irina

    2017-01-01

    Full Text Available In order to support the disposal of the proton beam window assembly of the Spallation Neutron Source beamline to the target station, waste classification analyses are performed. The window has a limited life-time due to radiation-induced material damage. Analyses include calculation of the radionuclide inventory and shielding analyses for the transport package/container to ensure that the container is compliant with the transportation and waste management regulations. In order to automate this procedure and minimize manual work a script in Perl language was written.

  13. Microsoft Windows Server Administration Essentials

    CERN Document Server

    Carpenter, Tom

    2011-01-01

    The core concepts and technologies you need to administer a Windows Server OS Administering a Windows operating system (OS) can be a difficult topic to grasp, particularly if you are new to the field of IT. This full-color resource serves as an approachable introduction to understanding how to install a server, the various roles of a server, and how server performance and maintenance impacts a network. With a special focus placed on the new Microsoft Technology Associate (MTA) certificate, the straightforward, easy-to-understand tone is ideal for anyone new to computer administration looking t

  14. Technology Solutions for Existing Homes Overview: Quantifying the Financial Benefits of Multifamily Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-04-01

    In this project, the U.S. Department of Energy Building America team Partnership for Advanced Residential Retrofit (PARR) worked with Elevate Energy on three tasks: to conduct pre- and post-retrofit analysis on the income and expense data of 13 Chicago-area multifamily buildings, to compare Chicago income and expense data to two national samples, and to explore the ramifications that energy-efficiency retrofits have on nine Chicago-area neighborhoods. The project team collected building, energy, and income and expense data from multiple private and public sources.

  15. Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community

    Energy Technology Data Exchange (ETDEWEB)

    Gates, C. [Building Science Corporation, Somerville, MA (United States); Neuhauser, K. [Building Science Corporation, Somerville, MA (United States)

    2014-03-01

    Between December, 2009 and December, 2012, 42 deep energy retrofit (DER) projects were completed through a pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. Thirty-seven of these projects were comprehensive retrofits while five were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. Building Science Corporation developed a consistent "package" of measures in terms of the performance targeted for major building components. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average.

  16. Design and retrofit of radiation monitoring system for the PWR nuclear power plant

    International Nuclear Information System (INIS)

    Zhang Tao; Xiong Guohua; Lang Yukai; Guo Wei

    2011-01-01

    Radiation monitoring system is important for the PWR nuclear power plant, and the research of design methods and principles for the radiation monitoring system can greatly improve the design ability of the system for PWR nuclear power plant, and reduce the risk of system retrofit. According to the Nuclear power plant regulations and design specifications, and taking the design and retrofit experience of the radiation monitoring system in Daya Bay Nuclear Power Plant into account, the general design principles and requirements of the radiation monitoring system in the PWR nuclear power plant is proposed, and the retrofit method of the radiation monitoring system in Daya Bay Nuclear Power Plant is briefly introduced. (authors)

  17. A New Method of Remote Control Checking for Substation Monitoring System Retrofit

    Science.gov (United States)

    Qiongliang, Chen; Li, Chen; Lei, Zhang; Gang, Chen; Feng, Qi; Yale, Xu

    2017-05-01

    In the process of monitoring system retrofit of 500kV Ouhai substation without power cut, because there is no design of remote control outlet plate on the measuring and control device, the remote control checking work cannot be completed by traditional method. After further study of the new and old monitoring system structure and the Siemens 8FW protocol, this paper presents a new method of remote control checking, and applies it in the field successfully, which improved the reliability and efficiency of the remote control checking work significantly. The retrofit scheme in this paper provides certain reference for the same type substation monitoring system retrofit in future.

  18. Measure Guideline: Deep Energy Enclosure Retrofit for Double-Stud Walls

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-06-01

    This Measure Guideline describes a deep energy enclosure retrofit (DEER) solution that provides insulation to the interior of the wall assembly with the use of a double stud wall. The guide describes two approaches to retrofitting the existing the walls: one involving replacement of the existing cladding, and the other that leaves the existing cladding in place. It discusses the design principles related to the use of various insulation types, and provides strategies and procedures for implementing the double stud wall retrofit. It also evaluates important moisture-related and indoor air quality measures that need to be implemented to achieve a durable, high performance wall.

  19. Measure Guideline: Deep Energy Enclosure Retrofit for Double-Stud Walls

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-06-22

    This Measure Guideline describes a deep energy enclosure retrofit solution that provides insulation to the interior of the wall assembly with the use of a double-stud wall. The guide describes two approaches to retrofitting the existing walls—one that involves replacing the existing cladding and the other that leaves the cladding in place. This guideline also covers the design principles related to the use of various insulation types and provides strategies and procedures for implementing the double-stud wall retrofit. It also includes an evaluation of important moisture-related and indoor air quality measures that need to be implemented to achieve a durable high-performance wall.

  20. Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Cautley, D.; Viner, J.; Lord, M.; Pearce, M.

    2012-12-01

    A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have been developed for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

  1. Mac configuration management at the Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Marcus, Allan B [Los Alamos National Laboratory

    2010-01-01

    The Los Alamos National Laboratory (LANL) had a need for central configuration management of non-Windows computers. LANL has three to five thousand Macs and an equal number of Linux based systems. The primary goal was to be able to inventory all non-windows systems and patch Mc OS X systems. LANL examined a number of commercial and open source solutions and ultimately selected Puppet. This paper will discuss why we chose Puppet, how we implemented it, and some lessons we learned along the way.

  2. Indoor temperature changes after retrofit: inferences based on electricity billing data for nonparticipants and participants in the BPA Residential Weatherization Program

    Energy Technology Data Exchange (ETDEWEB)

    Hirst, E.; White, D.

    1985-07-01

    This report discusses changes in indoor temperatures in response to retrofit improvements. The data on which this analysis is based are from an evaluation of the Bonneville Power Administration (BPA) interim Residential Weatherization Program. The BPA program, operated through participating private and public utilities throughout the Pacific Northwest, offered financial assistance (generally a cash rebate) to encourage installation of energy-efficiency improvements to existing homes in the region. These retrofits included attic, wall, floor and heating duct insulation; storm windows and doors; clock thermostats; and caulking and weatherstripping. This program, which operated during 1982 and 1983, weatherized 104 thousand homes at a total cost to BPA of $157 million. In mid-1983, staff at Oak Ridge National Laboratory and Evaluation Research Corporation began an evaluation of the BPA program. The primary focus of this evaluation was assessment of the actual electricity saving that can be attributed to the program (Hirst, et al., 1985). These savings estimates were used to help assess the economic attractiveness of the program to participants, the BPA power system, and the Pacific Northwest region as a whole.

  3. DNS BIND Server Configuration

    Directory of Open Access Journals (Sweden)

    Radu MARSANU

    2011-01-01

    Full Text Available After a brief presentation of the DNS and BIND standard for Unix platforms, the paper presents an application which has a principal objective, the configuring of the DNS BIND 9 server. The general objectives of the application are presented, follow by the description of the details of designing the program.

  4. DNS BIND Server Configuration

    OpenAIRE

    Radu MARSANU

    2011-01-01

    After a brief presentation of the DNS and BIND standard for Unix platforms, the paper presents an application which has a principal objective, the configuring of the DNS BIND 9 server. The general objectives of the application are presented, follow by the description of the details of designing the program.

  5. Configuration of bioreactors

    NARCIS (Netherlands)

    Martens, D.E.; End, van den E.J.; Streefland, M.

    2014-01-01

    Lab-scale stirred-tank bioreactors (0.2–20 l) are used for fundamental research on animal cells and in process development and troubleshooting for large-scale production. In this chapter, different configurations of bioreactor systems are shortly discussed and setting up these different

  6. Ansible configuration management

    CERN Document Server

    Hall, Daniel

    2015-01-01

    This book is intended for anyone who wants to learn Ansible starting from the basics. Some experience of how to set up and configure Linux machines and a working knowledge of BIND, MySQL, and other Linux daemons is expected.

  7. An Evaluation of Windows-Based Computer Forensics Application Software Running on a Macintosh

    Directory of Open Access Journals (Sweden)

    Gregory H. Carlton

    2008-09-01

    Full Text Available The two most common computer forensics applications perform exclusively on Microsoft Windows Operating Systems, yet contemporary computer forensics examinations frequently encounter one or more of the three most common operating system environments, namely Windows, OS-X, or some form of UNIX or Linux. Additionally, government and private computer forensics laboratories frequently encounter budget constraints that limit their access to computer hardware. Currently, Macintosh computer systems are marketed with the ability to accommodate these three common operating system environments, including Windows XP in native and virtual environments. We performed a series of experiments to measure the functionality and performance of the two most commonly used Windows-based computer forensics applications on a Macintosh running Windows XP in native mode and in two virtual environments relative to a similarly configured Dell personal computer. The research results are directly beneficial to practitioners, and the process illustrates affective pedagogy whereby students were engaged in applied research.

  8. Deep Energy Retrofit Guidance for the Building America Solutions Center

    Energy Technology Data Exchange (ETDEWEB)

    Less, Brennan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-01-01

    The U.S. DOE Building America program has established a research agenda targeting market-relevant strategies to achieve 40% reductions in existing home energy use by 2030. Deep Energy Retrofits (DERs) are part of the strategy to meet and exceed this goal. DERs are projects that create new, valuable assets from existing residences, by bringing homes into alignment with the expectations of the 21st century. Ideally, high energy using, dated homes that are failing to provide adequate modern services to their owners and occupants (e.g., comfortable temperatures, acceptable humidity, clean, healthy), are transformed through comprehensive upgrades to the building envelope, services and miscellaneous loads into next generation high performance homes. These guidance documents provide information to aid in the broader market adoption of DERs.

  9. High-Performance Slab-on-Grade Foundation Insulation Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR, St. Paul, MN (United States); Mosiman, Garrett E. [NorthernSTAR, St. Paul, MN (United States)

    2015-09-01

    A more accurate assessment of slab-on-grade foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulation at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).

  10. Governance of innovative cleantech retrofitting in the shipping industry?

    DEFF Research Database (Denmark)

    Hermann, Roberto Rivas; Smink, Carla; Kerndrup, Søren

    Air pollution from maritime transportation has become an important public health and environmental concern. As result, new international regulations seek to reduce the pollutants issuing from marine fuels combustion. Marine cleaner technology has been regarded as the key solution to comply...... with regulations and reduce operation costs. However, definitions of maritime cleantech differ and range from end-of-pipe pollution control equipment, more efficient engines, improved hull-design and alternate propulsion fuels (LNG, methanol). Different constellations of actors seem to follow different cleantech...... in collaboration with the Danish Shipowners' Association. The partnership identifies innovative cleaner retrofittings as one of the key domains with the purpose to improve Danish shipping firms to create competitive advantage and comply with the new international regulations of air pollution avoidance at sea...

  11. High Power Solid State Retrofit Lamp Thermal Characterization and Modeling

    Directory of Open Access Journals (Sweden)

    J. Jakovenko

    2012-04-01

    Full Text Available Thermal and thermo-mechanical modeling and characterization of solid state lightening (SSL retrofit LED lamp are presented in this paper. Paramount importance is to design SSL lamps for reliability, in which thermal and thermo-mechanical aspects are key points. The main goal is to get a precise 3D thermal lamp model for further thermal optimization. Simulations are performed with ANSYS and CoventorWare software tools to compere different simulation approaches. Simulated thermal distribution has been validated with thermal measurement on a commercial 8W LED lamp. Materials parametric study has been carried out to discover problematic parts for heat transfer from power LEDs to ambient and future solutions are proposed. The objectives are to predict the thermal management by simulation of LED lamp, get more understanding in the effect of lamp shape and used materials in order to design more effective LED lamps and predict light quality, life time and reliability.

  12. Gas turbines for the rubber industry: Retrofit feasibility

    International Nuclear Information System (INIS)

    Demaria, F.; Pautasso, F.

    1992-01-01

    Cogeneration is becoming industry's choice to satisfy process requirements characterized by high energy demand and fairly steady thermal and electrical loads. This paper illustrated the suitability of cogeneration for the production of rubber and PVC floor tiles. The example studied here consists of a gas fuelled turboalternator set capable of producing 1,050 kW of electric power. The energy plant is equipped with a heat recovery system and a post-combustor for the production of a diathermic fluid used by the process equipment. The paper points out how engineers overcame the installation problems due to the presence of existing process equipment and the necessity for continuous plant operation during retrofitting. Attention is given to the energy and cost feasibility aspects of this intervention

  13. Exceptional and Spinorial Conformal Windows

    DEFF Research Database (Denmark)

    Mojaza, Matin; Pica, Claudio; Ryttov, Thomas

    2012-01-01

    We study the conformal window of gauge theories containing fermionic matter fields, where the gauge group is any of the exceptional groups with the fermions transforming according to the fundamental and adjoint representations and the orthogonal groups where the fermions transform according...

  14. A Regional Spatial-Retrofitting Approach (RSRA to Geovisualise Regional Urban Growth: An application to the Golden Horseshoe in Canada

    Directory of Open Access Journals (Sweden)

    Eric Vaz

    2013-12-01

    Full Text Available Understanding urban change in particular for larger regions has been a great demur in both regional planning and geography. One of the main challenges has been linked to the potential of modelling urban change. The absence of spatial data and size of areas of study limit the traditional urban monitoring approaches, which also do not take into account visualization techniques that share information with the community. This is the case of the Golden Horseshoe in southern Ontario in Canada, one of the fastest growing regions in North America. An unprecedented change on the urban environment has been witnessed, leading to an increased importance of awareness for future planning in the region. With a population greater than 8 million, the Golden Horseshoe is steadily showing symptoms of becoming a mega-urban region, joining surrounding cities into a single and diversified urban landscape. However, little effort has been done to understand these changes, nor to share information with policy makers, stakeholders and investors. These players are in need of the most diverse information on urban land use, which is seldom available from a single source. The spatio-temporal effect of the growth of this urban region could very well be the birth of yet another North American megacity. Therefore, from a spatial perspective there is demand for joint collaboration and adoption of a regional science perspective including land cover and spatio-temporal configurations. This calls forth a novel technique that allows for assessment of urban and regional change, and supports decision-making without having the usual concerns of locational data availability. It is this sense, that we present a spatial-retrofitting model, with the objective of (i retrofitting spatial land use based on current land use and land cover, and assessing proportional change in the past, leading to four spatial timestamps of the Golden Horseshoe’s land use, while (ii integrating this in a

  15. Design and optimisation of novel configurations of stormwater constructed wetlands

    Science.gov (United States)

    Kiiza, Christopher

    2017-04-01

    Constructed wetlands (CWs) are recognised as a cost-effective technology for wastewater treatment. CWs have been deployed and could be retrofitted into existing urban drainage systems to prevent surface water pollution, attenuate floods and act as sources for reusable water. However, there exist numerous criteria for design configuration and operation of CWs. The aim of the study was to examine effects of design and operational variables on performance of CWs. To achieve this, 8 novel designs of vertical flow CWs were continuously operated and monitored (weekly) for 2years. Pollutant removal efficiency in each CW unit was evaluated from physico-chemical analyses of influent and effluent water samples. Hybrid optimised multi-layer perceptron artificial neural networks (MLP ANNs) were applied to simulate treatment efficiency in the CWs. Subsequently, predictive and analytical models were developed for each design unit. Results show models have sound generalisation abilities; with various design configurations and operational variables influencing performance of CWs. Although some design configurations attained faster and higher removal efficiencies than others; all 8 CW designs produced effluents permissible for discharge into watercourses with strict regulatory standards.

  16. Retrofitting Garden-Style Apartments in Brooklyn, New York

    Energy Technology Data Exchange (ETDEWEB)

    Nolen, Heather [Steven Winter Associates, Inc., Norwalk, CT (United States); Maxwell, Sean [Steven Winter Associates, Inc., Norwalk, CT (United States); Neri, Robin [Steven Winter Associates, Inc., Norwalk, CT (United States); Grab, Joanna [Steven Winter Associates, Inc., Norwalk, CT (United States)

    2016-02-01

    This research effort sought to achieve a solution package that yields energy savings greater than 30% over the pre-existing conditions in a minimally intrusive multifamily retrofit project. The Consortium for Advanced Residential Buildings (CARB) partnered with L+M Development Partners, Inc. on a Mitchell-Lama Housing Program project, Marcus Garvey Village, in Brooklyn, NY (Climate Zone 4A). The Mitchell-Lama Housing Program is a form of housing subsidy in the state of New York that provides affordable rental and cooperative housing to moderate- and middle-income families. Marcus Garvey Village was founded in 1975 and contains 625 residential units (ranging from studios to 5-bedroom units) in thirty-two 4-story garden-style apartment structures built with concrete and faced in light brown brick. The single largest challenge for implementation of energy conservation measures at Marcus Garvey was working within occupied spaces. Measures are being implemented in phases to minimize disruption. As of August 2015, the retrofit work is over 50% complete. The wall insulation, sealing of the through wall AC vent, and installation of new oil-filled electric baseboards with advanced controls are conducted at one time, limiting disruption to the living room space. In a similar fashion, the kitchen work is done, then the bathroom. The final selection of energy conservation measures is projected to save 26.5% in source energy with a cost just under $3.7 million and utility bill savings of nearly $480,000 (of an average $1.8 million annual utility cost for the development).

  17. Implementation of an RHR/LPSI pump coupling retrofit program

    International Nuclear Information System (INIS)

    Dudiak, J.G.; Koch, R.P.; Orewyler, R.; Tipton, J.W.

    1994-01-01

    Nuclear plant operating experience has shown the RHR and LPSI services to be very demanding on pumps. The systems handle borated water at high temperatures and pressures with frequent step changes in both temperature and pressure. Additionally, the industry trend towards reduced flow rates during plant mid-loop (reduced inventory) conditions has resulted in extended pump operation at flow rates significantly below the pump best efficiency point flow. Operation at these low flow fates is known to cause high thrust loads and large shaft deflections. The combination of these and other factors have resulted in short mechanical seal life and short motor bearing life, thus requiring frequent pump and motor maintenance. For many nuclear plants, including Southern California Edison's (SCE) San Onofre Units 2 and 3, these pumps have represented a major operations and maintenance (O ampersand M) expenditure and a significant source of radiation exposure to plant personnel. SCE management determined that a pump upgrade was justified to reduce the O ampersand M costs and to improve plant availability. SCE decided to proceed with a pump retrofit program to improve the pump maintainability, reliability and availability. Installation was completed for four LPSI pumps at San Onofre Units 2 and 3 during the Cycle 7 refueling outages in 1993. A key to the program's success was the removal of many traditional supplier and customer barriers and revision of supplier and customer roles to create a unified team. This paper traces the RHR/LPSI retrofit program for San Onofre from problem identification to project implementation. The team approach used for this program and the lessons learned may be useful to other utilities and vendors when evaluating or implementing system and equipment upgrades

  18. Acoustic emission of retrofitted fiber-wrapped columns

    Science.gov (United States)

    El Echary, Hazem; Mirmiran, Amir

    1998-03-01

    In recent years, fiber-wrapping technique has become increasingly popular for retrofitting of existing bridge pier columns in seismic zones. By the way of confinement, the external jacket enhances strength, ductility and shear performance of the column. However, since state of the concrete core is not visible from outside of the jacket, it is of great necessity to develop proper non-destructive methods to evaluate structural integrity of the column. Extensive research on FRP-confined concrete at the University of Central Florida has shown that failure of such hybrid columns is often accompanied by considerable audible and sub-audible noise, making acoustic emission (AE) a viable NDE technique for retrofitted columns. Acoustic emission from fiber-wrapped concrete specimens were monitored. A total of 24 concrete specimens with two types of construction (bonded and unbonded) and four different number of layers (1, 3, 5 and 7) were tested under uniaxial compression. All specimens were made of S-glass fabric and polyester resin with a core diameter of 6' and a length of 12'. Some of the specimens were subjected to cycles of loading and unloading to examine the presence of the Kaiser and the Felicity effects. A 4-channel AEDSP-32/16 (Mistras-2001) machine from Physical Acoustics Corp. was used for the experiments. Results indicate that AE energy and the number of AE counts can both be good representatives for the response of confined concrete. Further, plots of AE energy versus load follows the same bilinear trend that has been observed in the stress-strain response of such specimens. Finally, Felicity effect was observed in all composite specimens.

  19. Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

    2013-07-31

    The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

  20. Full-scale demonstration of low-NO{sub x} cell{trademark} burner retrofit. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Eckhart, C.F.; Kitto, J.B.; Kleisley, R.J. [and others

    1994-07-01

    The objective of the Low-NO{sub x} Cell{trademark}Burner (LNCB{trademark}) demonstration is to evaluate the applicability of this technology for reducing NO{sub x} emissions in full-scale, cell burner-equipped boilers. More precisely, the program objectives are to: (1) Achieve at least a 50% reduction in NO{sub x} emissions. (2) Reduce NO{sub x} with no degradation to boiler performance or life of the unit. (3) Demonstrate a technically and economically feasible retrofit technology. Cell burner equipped boilers comprise 13% of the Pre-New Source Performance Standards (NSPS) coal-fired generating capacity. This relates to 34 operating units generating 23,639 MWe, 29 of which are opposed wall fired with two rows of two-nozzle cell burners on each wall. The host site was one of these 29. Dayton Power & Light offered use of J.M. Stuart Station`s Unit No. 4 as the host site. It was equipped with 24, two-nozzle cell burners arranged in an opposed wall configuration. To reduce NO{sub x} emissions, the LNCB{trademark} has been designed to delay the mixing of the fuel and combustion air. The delayed mixing, or staged combustion, reduces the high temperatures normally generated in the flame of a standard cell burner. A key design criterion for the burner was accomplishing delayed fuel-air mixing with no pressure part modifications to facilitate a {open_quotes}plug-in{close_quotes} design. The plug-in design reduces material costs and outage time required to complete the retrofit, compared to installing conventional, internally staged low-NO{sub x} burners.

  1. Trial Demonstration of Area Lighting Retrofit: Yuma Border Patrol, Yuma Arizona

    Energy Technology Data Exchange (ETDEWEB)

    Wilkerson, Andrea M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McCullough, Jeffrey J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    The Yuma Sector Border Patrol Area is a high flux lighting application in a high temperature environment, presenting a formidable challenge for light-emitting diodes (LEDs). This retrofit is an Energy Savings Performance Contract ENABLE project under the U.S. Department of Energy (DOE) Federal Energy Management Program. If high flux LED technology performs well in a region with high ambient temperature and solar radiation, it can perform well in most outdoor environments. The design process for the Yuma retrofit has already provided valuable knowledge to CBP and DOE. The LED lighting system selected for the retrofit is expected to reduce energy consumption 69% compared to the incumbent quartz metal halide (QMH) lighting system. If the LED lighting system is installed, GATEWAY will continue to document and disseminate information regarding the installation and long-term performance so that others may also gain valuable knowledge from the Yuma Sector Border Patrol Area lighting retrofit.

  2. Study on the application of ambient vibration tests to evaluate the effectiveness of seismic retrofitting

    Science.gov (United States)

    Liang, Li; Takaaki, Ohkubo; Guang-hui, Li

    2018-03-01

    In recent years, earthquakes have occurred frequently, and the seismic performance of existing school buildings has become particularly important. The main method for improving the seismic resistance of existing buildings is reinforcement. However, there are few effective methods to evaluate the effect of reinforcement. Ambient vibration measurement experiments were conducted before and after seismic retrofitting using wireless measurement system and the changes of vibration characteristics were compared. The changes of acceleration response spectrum, natural periods and vibration modes indicate that the wireless vibration measurement system can be effectively applied to evaluate the effect of seismic retrofitting. The method can evaluate the effect of seismic retrofitting qualitatively, it is difficult to evaluate the effect of seismic retrofitting quantitatively at this stage.

  3. Finite Element Evaluation of Two Retrofit Options to Enhance the Performance of Cable Media Barriers.

    Science.gov (United States)

    2009-06-30

    This report summarizes the finite element modeling and simulation efforts on evaluating the performance of cable median barriers including the current and several proposed retrofit designs. It also synthesizes a literature review of the performance e...

  4. Building America Case Study: Quantifying the Financial Benefits of Multifamily Retrofits, Chicago, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    2016-04-01

    Increasing the adoption of energy efficient building practices will require the energy sector to increase their understanding of the way that retrofits affect multifamily financial performance as well as how those indicators are interpreted by the lending and appraisal industries. This project analyzed building, energy, and financial program data as well as other public and private data to examine the relationship between energy efficiency retrofits and financial performance on three levels: building, city, and community. The project goals were to increase the data and analysis in the growing body of multifamily financial benefits work as well provide a framework for other geographies to produce similar characterization. The goals are accomplished through three tasks: Task one: A pre- and post-retrofit analysis of thirteen Chicago multifamily buildings. Task two: A comparison of Chicago income and expenses to two national datasets. Task three: An in-depth look at multifamily market sales data and the subsequent impact of buildings that undergo retrofits.

  5. Seismic retrofit of cruciform-shaped columns in the Aurora Avenue Bridge using FRP wrapping.

    Science.gov (United States)

    2010-08-01

    Experimental tests were conducted on seven 1/3-scale column specimens to evaluate the vulnerabilities of existing cruciform-shaped columns and to develop appropriate retrofit measures that address the identified vulnerabilities. The specimens represe...

  6. Socio-economic effect of seismic retrofit implemented on bridges in the Los Angeles highway network.

    Science.gov (United States)

    2008-12-01

    This research studied socio-economic effect of the seismic retrofit implemented on bridges in Los Angeles Area : Freeway Network. Firstly, advanced FE (Finite Element) modeling and nonlinear time history analysis are carried out to : evaluate the sei...

  7. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: NEW CONDENSATOR, INC.--THE CONDENSATOR DIESEL ENGINE RETROFIT CRANKCASE VENTILATION SYSTEM

    Science.gov (United States)

    EPA's Environmental Technology Verification Program has tested New Condensator Inc.'s Condensator Diesel Engine Retrofit Crankcase Ventilation System. Brake specific fuel consumption (BSFC), the ratio of engine fuel consumption to the engine power output, was evaluated for engine...

  8. Effects of CFRP retrofit on impact response of shear-deficient scaled reinforced concrete beams

    Directory of Open Access Journals (Sweden)

    Erfan Shafei

    Full Text Available An experimental procedure is carried out to investigate response features of semi-deep reinforced concrete (RC beams with dominant static shear failure subjected to low-velocity impact dynamic load both in intact and retrofitted cases. Built specimens have scaled geometry and material properties preserving physical similarity with full-scale members and are strengthened using externally bonded carbon fiber reinforced polymer (CFRP sheets. Conducted tests gather reliable and robust data revealing notable stiffness and strength recovery within skin attachment. Desired performance criterion is detected here as concrete flexural cracking along span only when brittle shear collapse is prevented. Peak absorbed impulse capacity is attained for unidirectional carbon fiber retrofit. Stiffness is recovered initially during first impacts and then starts degrading due to rupture of horizontal fibers in cross-ply retrofit, but provided stiffness is stable for unidirectional retrofit during all impacts.

  9. Community-Scale Attic Retrofit and Home Energy Upgrade Data Mining

    Energy Technology Data Exchange (ETDEWEB)

    Berman, M. [Alliance for Residential Building Innovation, Davis, CA (United States); Smith, P. [Alliance for Residential Building Innovation, Davis, CA (United States); Jackson, J. [Alliance for Residential Building Innovation, Davis, CA (United States)

    2015-05-01

    Residential retrofit is an essential element of any comprehensive strategy for improving residential energy efficiency, yet remains a challenging proposition to sell to homeowners due to low levels of awareness and lack of financial incentive. The Alliance for Residential Building Innovation (ARBI) implemented a project to increase residential retrofits in Davis, CA called Retrofit Your Attic developed and appropriate data sets were uploaded to the Building America Field Data Repository (BAFDR). Two key conclusions are a broad based public awareness campaign is needed to increase understanding of the makeup and benefits of residential retrofits and a dramatic shift is needed so that efficient homes are appraised and valued at higher levels. The SAVE Act, proposed bipartisan federal legislation [S.1106], offers one way to accomplish this.

  10. The reHABITAT Guide: For Energy- and Resource-Efficient Retrofit Strategies

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-07-01

    This guide seeks to advance the goal of the U.S. Department of Energy’s Existing Residential Buildings Program (ERBP): to develop approaches that will enable the housing retrofit industry to deliver energy-efficient housing improvements.

  11. System and Method for Retrofit Mechanism for Motorizing A Manual Turret

    National Research Council Canada - National Science Library

    Schmitz, John J; Petrovich, Paul A; Stormer, A. D; Washburn, Robert G

    2006-01-01

    A mechanism for retrofitting a turret that has a manual rotation system with a motorized turret rotation system includes a gear box mechanically coupled to the turret, an electrically powered prime...

  12. Standard Measurement & Verification Plan for Lighting Equipment Retrofit or Replacement Projects

    Energy Technology Data Exchange (ETDEWEB)

    Richman, Eric E.

    2009-11-04

    This document provides a framework for a standard Measurement and Verification (M&V) plan for lighting projects. It was developed to support cost-effective retrofits (partial and complete replacements) of lighting systems and is intended to provide a foundation for an M&V plan for a lighting retrofit utilizing a "best practice" approach, and to provide guidance to site owners, contractors, and other involved organizations on what is essential for a robust M&V plan for lighting projects. This document provides examples of appropriate elements of an M&V plan, including the calculation of expected energy savings. The standard M&V plan, as provided, also allows for consistent comparison with other similar lighting projects. Although intended for lighting retrofit applications, M&V plans developed per this framework document may also be used for other non-lighting technology retrofits and new installations.

  13. Retrofit SCR system for NOx control from heavy-duty mining equipment

    International Nuclear Information System (INIS)

    Mannan, M.A.

    2009-01-01

    Diesel engines are used extensively in the mining industry and offer many advantages. However, particulate matter (PM) emissions and nitrogen oxide emissions (NOx) are among its disadvantages. A significant concern related to PM and NOx in an underground mine involves the use of diesel exhaust after treatment systems such as diesel particulate filters and selective catalytic reduction (SCR). This presentation discussed NOx and PM control and provided a description of an SCR system and examples of SCR retrofits. Options for NOx control were discussed and a case study involving the installation of an SCR retrofit system in an underground mine operated by Sifto Salt was also presented. The purpose of the case study was to identify cost effective retrofit solutions to lower nitrogen dioxide emissions from heavy-duty trucks operating in underground mines. The case study illustrated and presented the candidate vehicle, baseline emissions, a BlueMax SCR retrofit solution, and BlueMax installation. 1 tab., 6 figs.

  14. University of Maryland Wall Washer Retrofit - LED Modules Replace Halogen Lamps in a Performing Arts Center

    Energy Technology Data Exchange (ETDEWEB)

    Wilkerson, Andrea M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Abell, Thomas C. [Univ. of Maryland, College Park, MD (United States); Perrin, Tess E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-08-03

    The University of Maryland (UMD) began retrofitting halogen wall washers in the Clarice Smith Performing Arts Center (CSPAC) in April 2014. The U.S. Department of Energy (DOE) Solid-State Lighting (SSL) GATEWAY program documented this process through the final installation in March 2015, summarized in this report. The wall washers illuminate hallways lining the atrium, providing task illuminance for transitioning between spaces and visual interest to the atrium boundaries. The main goals of the retrofit were to maintain the visual appearance of the space while reducing maintenance costs – energy savings was considered an additional benefit by UMD Facilities Management. UMD Facilities Management is pleased with the results of this retrofit, and continues to initiate LED retrofit projects across the UMD campus.

  15. Tips for daylighting with windows

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Alastair [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Selkowitz, Stephen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-10-01

    These guidelines provide an integrated approach to the cost-effective design of perimeter zones in new commercial buildings and existing building retrofits. They function as a quick reference for building designers, through a set of easy steps and rules-of-thumb, emphasizing “how-to” practical details. References are given to more detailed sources of information, should the reader wish to go further. The design method used in this document emphasizes that building decisions should be made within the context of the whole building as a single functioning system rather than as an assembly of distinct parts. This integrated design approach looks at the ramifications of each individual system decision on the whole building. For example, the decision on glazing selection will have an effect on lighting, mechanical systems, and interior design. Therefore, the entire design team should participate and influence this glazing decision—which typically rests with the architect alone. The benefit of an integrated design approach is a greater chance of success towards long-term comfort and sustained energy savings in the building.

  16. Solar repowering/industrial retrofit systems study: Gulf Mt. Taylor Uranium Mill solar retrofit. Final technical report

    International Nuclear Information System (INIS)

    1980-06-01

    This report covers the efforts in a nine month study to develop a site-specific conceptual design for solar industrial process heat retrofit of the Gulf Mt. Taylor Uranium Mill. This has resulted in preparation of a System Requirements Specification, conduct of trade studies leading to selection of a system concept, and conceptual design, performance, cost estimating and economic analysis of the selected concept. A baseline system with no storage and an alternative system with extended storage were evaluated. The baseline system with no storage was selected because it provides the best overall opportunity for fuel displacement, operating experience in industrial application and successful demonstration in the near term for both DOE and the user

  17. Probabilistic risk assessment of a modern architecture building: analysis of the original building and retrofitting proposals

    OpenAIRE

    Rodrigues, H.; Romão, X.; Varum, H.; Arêde, A.; Costa, A.; Delgado, R.

    2008-01-01

    The seismic vulnerability of an existing building representative of modern architecture style is presented herein. To improve its seismic response, a retrofitting solution consisting of an x-bracing system associated to a shear-link dissipater was analysed. The effectiveness of the retrofit was measured by carrying out a seismic fragility analysis, considering a numerical model accounting for the nonlinear behaviour under earthquakes of both RC elements and infill masonry walls. I...

  18. Measure Guideline. Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-05-29

    This Measure Guideline provides design and construction information for a deep energy enclosure retrofit solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat wood-framed roof with brick masonry exterior walls using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat wood-framed roofs with wood-framed exterior walls.

  19. Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-05-01

    This Measure Guideline provides design and construction information for a deep energy enclosure retrofit (DEER) solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat, wood-framed roof with brick masonry exterior walls, using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat, wood-framed roofs with wood-framed exterior walls.

  20. Investigation and Retrofitting Proposal for a Panbo Type House in Sisimiut, Greenland

    DEFF Research Database (Denmark)

    Qu, Jing; Vladyková, Petra; Villumsen, Arne

    since December 2010. The results of the investigation show that the house has some serious problems influencing proper functions, such as thermal bridges, poor thermal comfort and high energy consumption. A retrofitting plan, including having an additional paper insulation layer and exterior climate...... to the harsh climate in Greenland and the low building standard in the earlier period, it is still a major challenge for Greenlandic building industry to retrofit existing buildings....

  1. Multifamily Retrofit Project Manager Job/Task Analysis and Report: September 2013

    Energy Technology Data Exchange (ETDEWEB)

    Owens, C. M.

    2013-09-01

    The development of job/task analyses (JTAs) is one of three components of the Guidelines for Home Energy Professionals project and will allow industry to develop training resources, quality assurance protocols, accredited training programs, and professional certifications. The Multifamily Retrofit Project Manager JTA identifies and catalogs all of the tasks performed by multifamily retrofit project managers, as well as the knowledge, skills, and abilities (KSAs) needed to perform the identified tasks.

  2. An analysis and retrofit of the acoustics at Image Creators Health and Beauty Salon

    Science.gov (United States)

    Ellis, Donna

    2002-11-01

    This paper discusses the analysis and retrofit of the acoustics in a high-volume beauty salon in Severna Park, MD. The major issues in what was designed to be a serene environment are reverberation times of 1-1.68 s in the mid- to upper-frequency range. Employee and customer complaints include heightened stress, vocal strain, headaches, and poor intelligibility. Existing analysis and acoustical retrofit solutions will be demonstrated.

  3. Multiobjective optimisation of energy systems and building envelope retrofit in a residential community

    International Nuclear Information System (INIS)

    Wu, Raphael; Mavromatidis, Georgios; Orehounig, Kristina; Carmeliet, Jan

    2017-01-01

    Highlights: • Simultaneous optimisation of building envelope retrofit and energy systems. • Retrofit and energy systems change interact and should be considered simultaneously. • Case study quantifies cost-GHG emission tradeoffs for different retrofit options. - Abstract: In this paper, a method for a multi-objective and simultaneous optimisation of building energy systems and retrofit is presented. Tailored to be suitable for the diverse range of existing buildings in terms of age, size, and use, it combines dynamic energy demand simulation to explore individual retrofit scenarios with an energy hub optimisation. Implemented as an epsilon-constrained mixed integer linear program (MILP), the optimisation matches envelope retrofit with renewable and high efficiency energy supply technologies such as biomass boilers, heat pumps, photovoltaic and solar thermal panels to minimise life cycle cost and greenhouse gas (GHG) emissions. Due to its multi-objective, integrated assessment of building transformation options and its ability to capture both individual building characteristics and trends within a neighbourhood, this method is aimed to provide developers, neighbourhood and town policy makers with the necessary information to make adequate decisions. Our method is deployed in a case study of typical residential buildings in the Swiss village of Zernez, simulating energy demands in EnergyPlus and solving the optimisation problem with CPLEX. Although common trade-offs in energy system and retrofit choice can be observed, optimisation results suggest that the diversity in building age and size leads to optimal strategies for retrofitting and building system solutions, which are specific to different categories. With this method, GHG emissions of the entire community can be reduced by up to 76% at a cost increase of 3% compared to the current emission levels, if an optimised solution is selected for each building category.

  4. The impacts of household retrofit and domestic energy efficiency schemes: A large scale, ex post evaluation

    International Nuclear Information System (INIS)

    Webber, Phil; Gouldson, Andy; Kerr, Niall

    2015-01-01

    There is widespread interest in the ability of retrofit schemes to shape domestic energy use in order to tackle fuel poverty and reduce carbon emissions. Although much has been written on the topic, there have been few large-scale ex post evaluations of the actual impacts of such schemes. We address this by assessing domestic energy use before and after the Kirklees Warm Zone (KWZ) scheme, which by fitting insulation in 51,000 homes in the 2007–2010 period is one of the largest retrofit schemes completed in the UK to date. To do this, we develop and apply a new methodology that isolates the impacts of retrofit activity from broader background trends in energy use. The results suggest that the actual impacts of the KWZ scheme have been higher than predicted, and that the scale of any performance gaps or rebound effects have been lower than has often been assumed. They also suggest that impacts on energy use in lower income areas are consistent with predictions, but that impacts in middle and higher income areas are higher than predicted. These findings support the case for the wider and/or accelerated adoption of domestic retrofit schemes in other contexts. -- Highlights: •A large scale, ex post evaluation of the impacts of a household retrofit scheme. •A new methodology to separate retrofit impacts from background trends. •Shows impacts of retrofit have been 1.2–1.7 times higher than predicted. •Impacts as predicted in lower income areas, higher in middle and upper income areas. •Findings support the case for the wider and faster adoption of domestic retrofit

  5. Decision process for the retrofit of municipal buildings with solar energy systems: a technical guide

    Energy Technology Data Exchange (ETDEWEB)

    Licciardello, Michael R.; Wood, Brian; Dozier, Warner; Braly, Mark; Yates, Alan

    1980-11-01

    As a background for solar applications, the following topics are covered: solar systems and components for retrofit installations; cost, performance, and quality considerations; and financing alternatives for local government. The retrofit decision process is discussed as follows: pre-screening of buildings, building data requirements, the energy conservation audit, solar system sizing and economics, comparison of alternatives, and implementation. Sample studies are presented for the West Valley Animal Shelter and the Hollywood Police Station. (MHR)

  6. Mechanical configuration and maintenance

    International Nuclear Information System (INIS)

    Brown, T.G.; Casini, G.; Churakov, G.F.

    1982-01-01

    The INTOR engineering design has been strongly influenced by considerations for assembly and maintenance. A maintenance philosophy was established at the outset of the conceptual design to insure that the tokamak configuration would be developed to accommodate maintenance requirements. The main features of the INTOR design are summarized in this paper with primary emphasis on the impact of maintenance considerations. The most apparent configuration design feature is the access provided for torus maintenance. Particular attention was given to the size and location of superconducting magnets and the location of vacuum boundaries. All of the poloidal field (PF) coils are placed outside of the bore of the toroidal field (TF) coils and located above and below an access opening between adjacent TF coils through which torus sectors are removed. A magnet structural configuration consisting of mechanically attached reinforcing members has been designed which facilitates the open access space for torus sector removal. For impurity control, a single null poloidal divertor was selected over a double null design in order to maintain sufficient access for pumping and maintenance of the collector. A double null divertor was found to severely limit access to the torus with the addition of divertor collectors and pumping at the top. For this reason, a single null concept was selected in spite of the more difficult design problems associated with the required asymmetric PF system and higher particle loadings

  7. Large-scale building energy efficiency retrofit: Concept, model and control

    International Nuclear Information System (INIS)

    Wu, Zhou; Wang, Bo; Xia, Xiaohua

    2016-01-01

    BEER (Building energy efficiency retrofit) projects are initiated in many nations and regions over the world. Existing studies of BEER focus on modeling and planning based on one building and one year period of retrofitting, which cannot be applied to certain large BEER projects with multiple buildings and multi-year retrofit. In this paper, the large-scale BEER problem is defined in a general TBT (time-building-technology) framework, which fits essential requirements of real-world projects. The large-scale BEER is newly studied in the control approach rather than the optimization approach commonly used before. Optimal control is proposed to design optimal retrofitting strategy in terms of maximal energy savings and maximal NPV (net present value). The designed strategy is dynamically changing on dimensions of time, building and technology. The TBT framework and the optimal control approach are verified in a large BEER project, and results indicate that promising performance of energy and cost savings can be achieved in the general TBT framework. - Highlights: • Energy efficiency retrofit of many buildings is studied. • A TBT (time-building-technology) framework is proposed. • The control system of the large-scale BEER is modeled. • The optimal retrofitting strategy is obtained.

  8. Case study field evaluation of a systems approach to retrofitting a residential HVAC system

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

    2003-09-01

    This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

  9. Promoting seismic retrofit implementation through "nudge": using warranty as a driver.

    Science.gov (United States)

    Fujimi, Toshio; Tatano, Hirokazu

    2013-10-01

    This article proposes a new type of warranty policy that applies the "nudge" concept developed by Thaler and Sunstein to encourage homeowners in Japan to implement seismic retrofitting. Homeowner adaptation to natural disasters through loss reduction measures is known to be inadequate. To encourage proactive risk management, the "nudge" approach capitalizes on how choice architecture can influence human decision-making tendencies. For example, people tend to place more value on a warranty for consumer goods than on actuarial value. This article proposes a "warranty for seismic retrofitting" as a "nudge" policy that gives homeowners the incentive to adopt loss reduction measures. Under such a contract, the government guarantees all repair costs in the event of earthquake damage to the house if the homeowner implements seismic retrofitting. To estimate the degree to which a warranty will increase the perceived value of seismic retrofitting, we use field survey data from 1,200 homeowners. Our results show that a warranty increases the perceived value of seismic retrofitting by an average of 33%, and an approximate cost-benefit analysis indicates that such a warranty can be more economically efficient than an ex ante subsidy. Furthermore, we address the failure of the standard expected utility model to explain homeowners' decisions based on warranty evaluation, and explore the significant influence of ambiguity aversion on the efficacy of seismic retrofitting and nonanalytical factors such as feelings or trust. © 2013 Society for Risk Analysis.

  10. Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, James [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Moore, Mike [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Thompson, Margo [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2013-08-01

    Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost effectiveness of efficiency upgrade measures for a tenant-in-place deep energy retrofit (DER) at the Bay Ridge multifamily development in Annapolis, Maryland. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a "base scope" retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a "DER scope" which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

  11. *NEW* CRITICAL Windows Security patches

    CERN Multimedia

    2003-01-01

    On 3 October and 10 September 2003, Microsoft issued new CRITICAL security patches MS03-040 and MS03-039. They must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security holes and patches are at: MS03-039: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp MS03-040: http://cern.ch/it-div/news/hotfix-MS03-040.asp http://www.microsoft.com/technet/security/bulletin/MS03-040.asp

  12. Electrochromic Windows: Advanced Processing Technology

    Energy Technology Data Exchange (ETDEWEB)

    SAGE Electrochromics, Inc

    2006-12-13

    This project addresses the development of advanced fabrication capabilities for energy saving electrochromic (EC) windows. SAGE EC windows consist of an inorganic stack of thin films deposited onto a glass substrate. The window tint can be reversibly changed by the application of a low power dc voltage. This property can be used to modulate the amount of light and heat entering buildings (or vehicles) through the glazings. By judicious management of this so-called solar heat gain, it is possible to derive significant energy savings due to reductions in heating lighting, and air conditioning (HVAC). Several areas of SAGE’s production were targeted during this project to allow significant improvements to processing throughput, yield and overall quality of the processing, in an effort to reduce the cost and thereby improve the market penetration. First, the overall thin film process was optimized to allow a more robust set of operating points to be used, thereby maximizing the yield due to the thin film deposition themselves. Other significant efforts aimed at improving yield were relating to implementing new procedures and processes for the manufacturing process, to improve the quality of the substrate preparation, and the quality of the IGU fabrication. Furthermore, methods for reworking defective devices were developed, to enable devices which would otherwise be scrapped to be made into useful product. This involved the in-house development of some customized equipment. Finally, the improvements made during this project were validated to ensure that they did not impact the exceptional durability of the SageGlass® products. Given conservative estimates for cost and market penetration, energy savings due to EC windows in residences in the US are calculated to be of the order 0.026 quad (0.026×1015BTU/yr) by the year 2017.

  13. The flexibility window in zeolites.

    Science.gov (United States)

    Sartbaeva, Asel; Wells, Stephen A; Treacy, M M J; Thorpe, M F

    2006-12-01

    Today synthetic zeolites are the most important catalysts in petrochemical refineries because of their high internal surface areas and molecular-sieving properties. There have been considerable efforts to synthesize new zeolites with specific pore geometries, to add to the 167 available at present. Millions of hypothetical structures have been generated on the basis of energy minimization, and there is an ongoing search for criteria capable of predicting new zeolite structures. Here we show, by geometric simulation, that all realizable zeolite framework structures show a flexibility window over a range of densities. We conjecture that this flexibility window is a necessary structural feature that enables zeolite synthesis, and therefore provides a valuable selection criterion when evaluating hypothetical zeolite framework structures as potential synthetic targets. We show that it is a general feature that experimental densities of silica zeolites lie at the low-density edge of this window--as the pores are driven to their maximum volume by Coulomb inflation. This is in contrast to most solids, which have the highest density consistent with the local chemical and geometrical constraints.

  14. Modeling Environmental Tobacco Smoke (ETS) Infiltration in Low-Income Multifamily Housing before and after Building Energy Retrofits.

    Science.gov (United States)

    Fabian, Maria Patricia; Lee, Sharon Kitman; Underhill, Lindsay Jean; Vermeer, Kimberly; Adamkiewicz, Gary; Levy, Jonathan Ian

    2016-03-16

    Secondhand exposure to environmental tobacco smoke (ETS) in multifamily housing remains a health concern despite strong recommendations to implement non-smoking policies. Multiple studies have documented exposure to ETS in non-smoking units located in buildings with smoking units. However, characterizing the magnitude of ETS infiltration or measuring the impact of building interventions or resident behavior on ETS is challenging due to the complexities of multifamily buildings, which include variable resident behaviors and complex airflows between numerous shared compartments (e.g., adjacent apartments, common hallways, elevators, heating, ventilating and air conditioning (HVAC) systems, stack effect). In this study, building simulation models were used to characterize changes in ETS infiltration in a low income, multifamily apartment building in Boston which underwent extensive building renovations targeting energy savings. Results suggest that exterior wall air sealing can lead to increases in ETS infiltration across apartments, while compartmentalization can reduce infiltration. The magnitude and direction of ETS infiltration depends on apartment characteristics, including construction (i.e., level and number of exterior walls), resident behavior (e.g., window opening, operation of localized exhaust fans), and seasonality. Although overall ETS concentrations and infiltration were reduced post energy-related building retrofits, these trends were not generalizable to all building units. Whole building smoke-free policies are the best approach to eliminate exposure to ETS in multifamily housing.

  15. SEISMIC PERFORMANCE OF A PRECAST REINFORCED CONCRETE WALL WITH CUT-OUT OPENING RETROFITTED USING CARBON FIBRE STRIPS

    Directory of Open Access Journals (Sweden)

    Fofiu M.

    2015-05-01

    Full Text Available The Precast Reinforced Concrete Wall Panel (PRCWP presented in this paper is part of an experimental study regarding the seismic performance of precast reinforced concrete wall panels, strengthening strategies and investigation on the weakening induced by modifying the opening in these elements due to architectural demands, change of function of buildings or other reasons. The element presented is 1:1.2 scale typical Reinforced Concrete Wall Panel with a window opening used in Romania, in which the opening was changed to a door opening due to comfort considerations. The specimen was subjected to cyclic loading with the lateral loads being applied in displacement control of 0.1% drift ratio. This simulates the shear behaviour of the element. After testing the unstrengthen element we proceed to retrofit it using Carbon Fibre Strips anchored with Carbon Fibre Mash. The purpose of the paper is to present the strengthening strategy and restore the initial load bearing capacity of the element or even increase it. The experimental results of strengthen and unstrengthen specimens will be presented.

  16. Modeling Environmental Tobacco Smoke (ETS Infiltration in Low-Income Multifamily Housing before and after Building Energy Retrofits

    Directory of Open Access Journals (Sweden)

    Maria Patricia Fabian

    2016-03-01

    Full Text Available Secondhand exposure to environmental tobacco smoke (ETS in multifamily housing remains a health concern despite strong recommendations to implement non-smoking policies. Multiple studies have documented exposure to ETS in non-smoking units located in buildings with smoking units. However, characterizing the magnitude of ETS infiltration or measuring the impact of building interventions or resident behavior on ETS is challenging due to the complexities of multifamily buildings, which include variable resident behaviors and complex airflows between numerous shared compartments (e.g., adjacent apartments, common hallways, elevators, heating, ventilating and air conditioning (HVAC systems, stack effect. In this study, building simulation models were used to characterize changes in ETS infiltration in a low income, multifamily apartment building in Boston which underwent extensive building renovations targeting energy savings. Results suggest that exterior wall air sealing can lead to increases in ETS infiltration across apartments, while compartmentalization can reduce infiltration. The magnitude and direction of ETS infiltration depends on apartment characteristics, including construction (i.e., level and number of exterior walls, resident behavior (e.g., window opening, operation of localized exhaust fans, and seasonality. Although overall ETS concentrations and infiltration were reduced post energy-related building retrofits, these trends were not generalizable to all building units. Whole building smoke-free policies are the best approach to eliminate exposure to ETS in multifamily housing.

  17. Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office testbed

    Energy Technology Data Exchange (ETDEWEB)

    Thanachareonkit, Anothai; Lee, Eleanor S.; McNeil, Andrew

    2013-08-31

    Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Microstructured prismatic window films can be manufactured using low-cost, roll-to-roll fabrication methods and adhered to the inside surface of existing windows as a retrofit measure or installed as a replacement insulating glass unit in the clerestory portion of the window wall. A clear film patterned with linear, 50-250 micrometer high, four-sided asymmetrical prisms was fabricated and installed in the south-facing, clerestory low-e, clear glazed windows of a full-scale testbed facility. Views through the film were distorted. The film was evaluated in a sunny climate over a two-year period to gauge daylighting and visual comfort performance. The daylighting aperture was small (window-towall ratio of 0.18) and the lower windows were blocked off to isolate the evaluation to the window film. Workplane illuminance measurements were made in the 4.6 m (15 ft) deep room furnished as a private office. Analysis of discomfort glare was conducted using high dynamic range imaging coupled with the evalglare software tool, which computes the daylight glare probability and other metrics used to evaluate visual discomfort. The window film was found to result in perceptible levels of discomfort glare on clear sunny days from the most conservative view point in the rear of the room looking toward the window. Daylight illuminance levels at the rear of the room were significantly increased above the reference window condition, which was defined as the same glazed clerestory window but with an interior Venetian blind (slat angle set to the cut-off angle), for the equinox to winter solstice period on clear sunny days. For partly cloudy and overcast sky conditions, daylight levels were improved slightly. To reduce glare, the daylighting film was coupled with a diffusing film in an insulating glazing unit. The diffusing film retained the directionality of the

  18. Microsoft Windows Intune 20 Quickstart Administration

    CERN Document Server

    Overton, David

    2012-01-01

    This book is a concise and practical tutorial that shows you how to plan, set up and maintain Windows Intune and manage a group of PCs. If you are an administrator or partner who wants to plan, set up and maintain Windows Intune and manage a group of PCs then this book is for you . You should have a basic understanding of Windows administration, however, knowledge of Windows Intune would not be required.

  19. Beryllium window for an APS diagnostics beamline

    International Nuclear Information System (INIS)

    Sheng, I.C.; Yang, B.X.; Sharma, Y.S.

    1997-01-01

    A beryllium (Be) window for an Advanced Photon Source (APS) diagnostics beamline has been designed and built. The window, which has a double concave axisymmetrical profile with a thickness of 0.5 mm at the center, receives 160 W/mm 2 (7 GeV/100 mA stored beam) from an undulator beam. The window design as well as thermal and thermomechanical analyses, including thermal buckling of the Be window, are presented

  20. Configuration Management Program Plan

    International Nuclear Information System (INIS)

    1991-01-01

    Westinghouse Savannah River Company (WSRC) has established a configuration management (CM) plan to execute the SRS CM Policy and the requirements of the DOE Order 4700.1. The Reactor Restart Division (RRD) has developed its CM Plan under the SRS CM Program and is implementing it via the RRD CM Program Plan and the Integrated Action Plan. The purpose of the RRD CM program is to improve those processes which are essential to the safe and efficient operation of SRS production reactors. This document provides details of this plan

  1. Spatial scan statistics using elliptic windows

    DEFF Research Database (Denmark)

    Christiansen, Lasse Engbo; Andersen, Jens Strodl; Wegener, Henrik Caspar

    2006-01-01

    windows and propose a new way to present the information when a spatial point process is considered. This method gives smooth changes for smooth expansions of the set of clusters. A simulation study is used to show how the elliptic windows outperforms the usual circular windows. The proposed method...

  2. Spatial scan statistics using elliptic windows

    DEFF Research Database (Denmark)

    Christiansen, Lasse Engbo; Andersen, Jens Strodl; Wegener, Henrik Caspar

    of confocal elliptic windows and propose a new way to present the information when a spatial point process is considered. This method gives smooth changes for smooth expansions of the set of clusters. A simulation study is used to show how the elliptic windows outperforms the usual circular windows...

  3. Travailler avec Windows 7 au CERN

    CERN Multimedia

    CERN. Geneva

    2011-01-01

    Vue d'ensemble des nouveaux concepts et des changements dans l'interface utilisateur survenus dans Windows 7 depuis les versions antérieures de Windows (XP ou Vista). Le plan de migration à Windows 7 sera aussi débattu.

  4. Travailler avec Windows 7 au CERN

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    Vue d'ensemble des nouveaux concepts et des changements dans l'interface utilisateur survenus dans Windows 7 depuis les versions antérieures de Windows (XP ou Vista). Le plan de migration à Windows 7 sera aussi débattu.

  5. Modelling window opening behaviour in Danish dwellings

    DEFF Research Database (Denmark)

    Andersen, Rune Vinther; Olesen, Bjarne W.; Toftum, Jørn

    2011-01-01

    In this paper we present and analyse data from two studies of window opening behaviour in residential buildings in Denmark. Based on measurements of indoor environment, weather and window opening behaviour in 15 dwellings, we propose a model that will predict window opening behaviour. The data...

  6. Indoor Air Quality and Ventilation in Residential Deep Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Less, Brennan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-06-01

    Because airtightening is a significant part of Deep Energy Retrofits (DERs), concerns about ventilation and Indoor Air Quality (IAQ) have emerged. To investigate this, ventilation and IAQ were assessed in 17 non-smoking California Deep Energy Retrofit homes. Inspections and surveys were used to assess household activities and ventilation systems. Pollutant sampling performed in 12 homes included six-day passive samples of nitrogen dioxide (NO2), formaldehyde and air exchange rate (AER); time-resolved data loggers were used to measure particle counts. Half of the homes provided continuous mechanical ventilation. Despite these homes being twice as airtight (3.0 and 7.6 ACH50, respectively), their median AER was indistinguishable from naturally vented homes (0.36 versus 0.37 hr-1). Numerous problems were found with ventilation systems; however, pollutant levels did not reach levels of concern in most homes. Ambient NO2 standards were exceeded in some gas cooking homes that used legacy ranges with standing pilots, and in Passive House-style homes without range hoods exhausted to outside. Cooking exhaust systems were installed and used inconsistently. The majority of homes reported using low-emitting materials, and formaldehyde levels were approximately half those in conventional new CA homes (19.7 versus 36 μg/m3), with emissions rates nearly 40percent less (12.3 versus 20.6 μg/m2/hr.). Presence of air filtration systems led to lower indoor particle number concentrations (PN>0.5: 8.80E+06 PN/m3 versus 2.99E+06; PN>2.5: 5.46E+0.5 PN/m3 versus 2.59E+05). The results indicate that DERs can provide adequate ventilation and IAQ, and that DERs should prioritize source control, particle filtration and well-designed local exhaust systems, while still providing adequate continuous ventilation.

  7. An approach for holistic energy retrofitting based on assessment of economic viability and durability of energy saving measures

    DEFF Research Database (Denmark)

    Morelli, Martin

    2014-01-01

    saving measures and forget to consider, whether it is more prudent to demolished the building and erect a new building. An evaluation approach is presented to assess whether to retrofit an existing building or to demolish and replace it. The primary concept of the method is to develop a retrofitting...... as constraint to determine the amount of building retrofitting for implementation. The approach includes also durability assessments of the energy saving measures. An example is carried out to illustrate the application of the approach. The example highlights the importance of including risk assessment...... and durability evaluation of the energy saving measures when performing holistic energy retrofitting of buildings....

  8. Ames Optimized TCA Configuration

    Science.gov (United States)

    Cliff, Susan E.; Reuther, James J.; Hicks, Raymond M.

    1999-01-01

    Configuration design at Ames was carried out with the SYN87-SB (single block) Euler code using a 193 x 49 x 65 C-H grid. The Euler solver is coupled to the constrained (NPSOL) and the unconstrained (QNMDIF) optimization packages. Since the single block grid is able to model only wing-body configurations, the nacelle/diverter effects were included in the optimization process by SYN87's option to superimpose the nacelle/diverter interference pressures on the wing. These interference pressures were calculated using the AIRPLANE code. AIRPLANE is an Euler solver that uses a unstructured tetrahedral mesh and is capable of computations about arbitrary complete configurations. In addition, the buoyancy effects of the nacelle/diverters were also included in the design process by imposing the pressure field obtained during the design process onto the triangulated surfaces of the nacelle/diverter mesh generated by AIRPLANE. The interference pressures and nacelle buoyancy effects are added to the final forces after each flow field calculation. Full details of the (recently enhanced) ghost nacelle capability are given in a related talk. The pseudo nacelle corrections were greatly improved during this design cycle. During the Ref H and Cycle 1 design activities, the nacelles were only translated and pitched. In the cycle 2 design effort the nacelles can translate vertically, and pitch to accommodate the changes in the lower surface geometry. The diverter heights (between their leading and trailing edges) were modified during design as the shape of the lower wing changed, with the drag of the diverter changing accordingly. Both adjoint and finite difference gradients were used during optimization. The adjoint-based gradients were found to give good direction in the design space for configurations near the starting point, but as the design approached a minimum, the finite difference gradients were found to be more accurate. Use of finite difference gradients was limited by the

  9. Analysis of a grid window structure for RF cavities in a Muon cooling channel

    International Nuclear Information System (INIS)

    Ladran, A.; Li, D.; Moretti, A.; Rimmer, R.; Staples, J.; Virostek, S.; Zisman, M.

    2003-01-01

    We report on the electromagnetic and thermal analysis of a grid window structure for high gradient, low frequency RF cavities. Windows may be utilized to close the beam iris and increase shunt impedance of closed-cell RF cavities. This work complements previous work presented for windows made of solid beryllium foil. An electromagnetic and thermal analysis of the thin wall tubes in a grid pattern was conducted using both MAFIA4 and ANSYS finite element analyses. The results from both codes agreed well for a variety of grid configurations and spacing. The grid configuration where the crossing tubes touched was found to have acceptable E-Fields and H-Fields performance. The thermal profiles for the grid will also be shown to determine a viable cooling profile

  10. Accelerating the energy retrofit of commercial buildings using a database of energy efficiency performance

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Hong, Tianzhen; Piette, Mary Ann; Sawaya, Geof; Chen, Yixing; Taylor-Lange, Sarah C.

    2015-01-01

    Small and medium-sized commercial buildings can be retrofitted to significantly reduce their energy use, however it is a huge challenge as owners usually lack of the expertise and resources to conduct detailed on-site energy audit to identify and evaluate cost-effective energy technologies. This study presents a DEEP (database of energy efficiency performance) that provides a direct resource for quick retrofit analysis of commercial buildings. DEEP, compiled from the results of about ten million EnergyPlus simulations, enables an easy screening of ECMs (energy conservation measures) and retrofit analysis. The simulations utilize prototype models representative of small and mid-size offices and retails in California climates. In the formulation of DEEP, large scale EnergyPlus simulations were conducted on high performance computing clusters to evaluate hundreds of individual and packaged ECMs covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and service hot water. The architecture and simulation environment to create DEEP is flexible and can expand to cover additional building types, additional climates, and new ECMs. In this study DEEP is integrated into a web-based retrofit toolkit, the Commercial Building Energy Saver, which provides a platform for energy retrofit decision making by querying DEEP and unearthing recommended ECMs, their estimated energy savings and financial payback. - Highlights: • A DEEP (database of energy efficiency performance) supports building retrofit. • DEEP is an SQL database with pre-simulated results from 10 million EnergyPlus runs. • DEEP covers 7 building types, 6 vintages, 16 climates, and 100 energy measures. • DEEP accelerates retrofit of small commercial buildings to save energy use and cost. • DEEP can be expanded and integrated with third-party energy software tools.

  11. Windows Command Line Administration Instant Reference

    CERN Document Server

    Mueller, John Paul

    2010-01-01

    The perfect companion to any book on Windows Server 2008 or Windows 7, and the quickest way to access critical information. Focusing just on the essentials of command-line interface (CLI), Windows Command-Line Administration Instant Reference easily shows how to quickly perform day-to-day tasks of Windows administration without ever touching the graphical user interface (GUI). Specifically designed for busy administrators, Windows Command-Line Administration Instant Reference replaces many tedious GUI steps with just one command at the command-line, while concise, easy to access answers provid

  12. Retrofitting adjustable speed drives for large induction motors

    International Nuclear Information System (INIS)

    Wuestefeld, M.R.; Merriam, C.H.; Porter, N.S.

    2004-01-01

    Adjustable speed drives (ASDs) are used in many power plants to control process flow by varying the speed of synchronous and induction motors. In applications where the flow requirements vary significantly, ASDs reduce energy and maintenance requirements when compared with drag valves, dampers or other methods to control flow. Until recently, high horsepower ASDs were not available for induction motors. However, advances in power electronics technology have demonstrated the reliability and cost effectiveness of ASDs for large horsepower induction motors. Emphasis on reducing operation and maintenance costs and increasing the capacity factor of nuclear power plants has led some utilities to consider replacing flow control devices in systems powered by large induction motors with ASDs. ASDs provide a high degree of reliability and significant energy savings in situations where full flow operation is not needed for a substantial part of the time. This paper describes the basic adjustable speed drive technologies available for large induction motor applications, ASD operating experience and retrofitting ASDs to replace the existing GE Boiling Water Reactor recirculation flow control system

  13. Retrofit of new digital control systems in existing power stations

    International Nuclear Information System (INIS)

    Smith, J.E.; Baird, C.F.

    1986-01-01

    With the notable exception of the Canadian CANDU nuclear power stations, little use has been made of digital control in North American nuclear stations. Recently, however, there has been renewed interest in such systems within the nuclear industry in response to demands for better ergonomics in control room design and the obsolescence of control equipment whose fundamental design has changed little in 20 yr. Early in 1985, Atomic Energy of Canada Limited was asked by New Brunswick Power to advise on the redesign of the control systems for two fossil-fired generating stations, Coleson Cove and Courtenay Bay Unit 4. Coleson Cove is to be converted from oil to coal firing with consequent extensive control system changes and Courtenay Bay Unit 4 required a low-cost solution to the problem of relocating its control room from the existing isolated location to the combined control center used by units 1, 2, and 3. In both cases, the recommended solution involves the retrofit of state-of-the-art digital control systems. Although the units involved are nonnuclear the experience is applicable

  14. Automatic FAÇADE Segmentation for Thermal Retrofit

    Science.gov (United States)

    Previtali, M.; Barazzetti, L.; Brumana, R.; Cuca, B.; Oreni, D.; Roncoroni, F.; Scaioni, M.

    2013-02-01

    In this paper we present an automated method to derive highly detailed 3D vector models of modern building façades from terrestrial laser scanning data. The developed procedure can be divided into two main steps: firstly the main elements constituting the façade are identified by means of a segmentation process, then the 3D vector model is generated including some priors on architectural scenes. The identification of main façade elements is based on random sampling and detection of planar elements including topology information in the process to reduce under- and over-segmentation problems. Finally, the prevalence of straight lines and orthogonal intersections in the vector model generation phase is exploited to set additional constraints to enforce automated modeling. Contemporary a further classification is performed, enriching the data with semantics by means of a classification tree. The main application field for these vector models is the design of external insulation thermal retrofit. In particular, in this paper we present a possible application for energy efficiency evaluation of buildings by mean of Infrared Thermography data overlaid to the façade model.

  15. Public Housing: A Tailored Approach to Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Conlin, Francis [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Podorson, David [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Alaigh, Kunal [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States)

    2014-06-01

    More than 1 million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation 10 ten housing units. Total source energy consumption savings was estimated at 6%-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.

  16. Public Housing: A Tailored Approach to Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J.; Conlin, F.; Podorson, D.; Alaigh, K.

    2014-06-01

    Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.

  17. Yorktowne Square condominium green roof retrofit and stormwater management plan

    Energy Technology Data Exchange (ETDEWEB)

    Perry, M.D. [Building Logics Inc., Virginia Beach, VA (United States)

    2005-07-01

    This paper provided details of a green roof retrofit and and stormwater management plan developed for the Yorktowne Square Condominiums, a 15.3 acre site located in the highly developed county of Fairfax, Virginia. The 4700 square foot green roof system was installed as the first step to implement an effective stormwater management plan. The loss of forested areas and increased impervious surfaces in the region has meant that stormwater drainage in the region is increasingly allowing trash, sediment and other pollutants to enter the Chesapeake Bay. A lightweight EnviroTech green roof system was used to address structural concerns due to the age of the buildings. The specialized modified bitumen membrane incorporated waterproofing, root barrier, water retention and drainage systems in a single layer. The Yorktowne plan will reduce the nutrient load in the Chesapeake Bay and maintain the 40 per cent nutrient reduction goal agreed to in 1987, in addition to not using pesticides, fertilizers or herbicides. Studies have shown that the living roof has increased stormwater retention by up to 80 per cent. The roof has been the subject of television shows and newspaper articles. It was concluded that Yorktowne has become a model for residential and business communities by demonstrating how green roofs and other stormwater management designs can be implemented to improve water quality, decrease erosive stormwater, and conserve resources in the Chesapeake Bay watershed. 1 fig.

  18. Assessment of a Hybrid Retrofit Gas Water Heater

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, Marc [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Weitzel, Elizabeth [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Backman, Christine [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2017-02-01

    This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the 1/2 inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit with lower storage volume and reduced gas input requirements. Simulations were completed under a 'peak day' sizing scenario with 183 gpd hot water loads in a Minnesota winter climate case. Full-year simulations were then completed in three climates (ranging from Phoenix to Minneapolis) for three hot water load scenarios (36, 57, and 96 gpd). Model projections indicate that the alternative hybrid offers an average 4.5% efficiency improvement relative to the 0.60 EF gas storage unit across all scenarios modeled. The alternative hybrid water heater evaluated does show promise, but the current low cost of natural gas across much of the country and the relatively small incremental efficiency improvement poses challenges in initially building a market demand for the product.

  19. Retrofitting tractors with rollover protective structures: perspective of equipment dealers.

    Science.gov (United States)

    Tonelli, S M; Donham, K J; Leedom-Larson, K; Sanderson, W; Purschwitz, M

    2009-10-01

    This study was one of a cluster of studies that originated via requests for proposals from the NIOSH National Agricultural Tractor Safety Initiative. The present study design consisted of several steps: (1) formation of an advisory group, (2) development and testing of a standard paper self-responding survey instrument, (3) sample selection of farm equipment dealers, (4) administration of the survey, (5) assessment and analysis of the survey, and (6) in-person response panel of dealers (n = 80) to review results of the questionnaire for further definition and sharpening of the recommendations from the survey. A key finding is that most dealers do not currently sell or install ROPS retrofit kits. Barriers cited by dealers included (1) actual or perceived lack of farmer demand, (2) injury liability, (3) expensive freight for ordering ROPS, (4) lack of dealer awareness of the magnitude of deaths from tractor overturns and the high life-protective factor of ROPS, and (5) difficulty and incursion of non-recoverable expenses in locating and obtaining specific ROPS. Despite not currently selling or installing ROPS, dealers responded favorably about their future potential role in ROPS promotion and sales. Dealers were willing to further promote, sell, and install ROPS if there was demand from farmers. Recommendations include establishing a ROPS "clearing house" that dealers could contact to facilitate locating and obtaining ROPS orders from customers. Additional recommendations include education and social marketing targeting farm machinery dealers as well farmers, manufacturers, and policy makers.

  20. Carbon Capture in the Cement Industry: Technologies, Progress, and Retrofitting.

    Science.gov (United States)

    Hills, Thomas; Leeson, Duncan; Florin, Nicholas; Fennell, Paul

    2016-01-05

    Several different carbon-capture technologies have been proposed for use in the cement industry. This paper reviews their attributes, the progress that has been made toward their commercialization, and the major challenges facing their retrofitting to existing cement plants. A technology readiness level (TRL) scale for carbon capture in the cement industry is developed. For application at cement plants, partial oxy-fuel combustion, amine scrubbing, and calcium looping are the most developed (TRL 6 being the pilot system demonstrated in relevant environment), followed by direct capture (TRL 4-5 being the component and system validation at lab-scale in a relevant environment) and full oxy-fuel combustion (TRL 4 being the component and system validation at lab-scale in a lab environment). Our review suggests that advancing to TRL 7 (demonstration in plant environment) seems to be a challenge for the industry, representing a major step up from TRL 6. The important attributes that a cement plant must have to be "carbon-capture ready" for each capture technology selection is evaluated. Common requirements are space around the preheater and precalciner section, access to CO2 transport infrastructure, and a retrofittable preheater tower. Evidence from the electricity generation sector suggests that carbon capture readiness is not always cost-effective. The similar durations of cement-plant renovation and capture-plant construction suggests that synchronizing these two actions may save considerable time and money.