WorldWideScience

Sample records for wash water renovation

  1. Viruses in renovated waters

    CSIR Research Space (South Africa)

    Nupen, EM

    1974-06-01

    Full Text Available , for permission to present this paper. ?8? References 1. REPORT. CONMITTEE ON ENVIRONMENTAL QUALITY ANAGEMEZIT OF PME SANITARY ENGINEERING DIVISION (1970). Engineering evaluation of virus hazard in water. Jour. Eng. Div. Proc. Am. Soc. Civ. Eng. SA 1, 7112... Water Systems, Austin, Texas, 1974 13. CARESON, G.F., WOODA.RD, F.E., WENTWORTII, D.P. and SPRODI, O.J. (1968) Virus inactivation on clay particles in natural waters. Journ. Wat. Pollut. Cont. Fed., 4Q R39, 7116. 14. MOSJ~EY, J.W. (1967...

  2. 27 CFR 19.328 - Wash water.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Wash water. 19.328 Section... THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Production Chemical By-Products § 19.328 Wash water. Water used in washing chemicals to remove spirits therefrom may be run into a wash tank or a distilling...

  3. Wash water waste pretreatment system

    Science.gov (United States)

    1977-01-01

    Investigations were completed on wash waters based on each candidate personal cleansing agent. Evaluations of coagulants, antifoam agents, and the effect of promising antifoams on the chemical precipitation were included. Based on these evaluations two candidate soaps as well as their companion antifoam agents were selected for further work. Operating parameters included the effect of soap concentration, ferric chloride concentration, duration of mixing, and pore size of depth filters on the degree of soap removal. The effect of pressure on water flow through filter cartridges and on the rate of decline of water flow was also investigated. The culmination of the program was the recommendation of a pretreatment concept based on chemical precipitation followed by pressure filtration.

  4. 21 CFR 1250.87 - Wash water.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wash water. 1250.87 Section 1250.87 Food and Drugs... Sanitation Facilities and Conditions on Vessels § 1250.87 Wash water. Where systems installed on vessels for wash water, as defined in § 1250.3(n), do not comply with the requirements of a potable water system...

  5. Wash water waste pretreatment system study

    Science.gov (United States)

    1976-01-01

    The use of real wash water had no adverse effect on soap removal when an Olive Leaf soap based system was used; 96 percent of the soap was removed using ferric chloride. Numerous chemical agents were evaluated as antifoams for synthetic wash water. Wash water surfactants used included Olive Leaf Soap, Ivory Soap, Neutrogena and Neutrogena Rain Bath Gel, Alipal CO-436, Aerosol 18, Miranol JEM, Palmeto, and Aerosol MA-80. For each type of soapy wash water evaluated, at least one antifoam capable of causing nonpersistent foam was identified. In general, the silicones and the heavy metal ions (i.e., ferric, aluminum, etc.) were the most effective antifoams. Required dosage was in the range of 50 to 200 ppm.

  6. Ultrafiltration to reuse laundering wash water

    DEFF Research Database (Denmark)

    Giagnorio, Mattia; Søtoft, Lene Fjerbæk; Tiraferri, Alberto

    2017-01-01

    Laundering industry consumes and discharges large amounts of water and surfactants, and the demand of surface active agents used for washing is increasing worldwide. Some of these substances are considered contaminants of emerging concern, as they persist in the environment. This work aimed...... at evaluating the feasibility of ultrafiltration as a method to treat the wash wastewater and possibly reuse the surfactant-rich permeate stream in laundry facilities. In particular, evaluation of surfactant recovery was performed through analysis of the permeate flux and properties obtained through polymeric...... and ceramic membranes. Wash water samples were collected at an industrial laundering facility for hospital linen and filtered through different ultrafiltration membranes with varying molecular weight cut-off. The critical micelle concentration of the detergent was quantified, and capillarity measurements were...

  7. An assessment of water, sanitation and hygiene (wash) practices ...

    African Journals Online (AJOL)

    An assessment of water, sanitation and hygiene (wash) practices and quality of routinely ... East African Medical Journal ... There was a high uptake of households with treated drinking water (92%), availability of hand washing facilities in ...

  8. The effect of silica in washing with geothermal water, Iceland

    International Nuclear Information System (INIS)

    Lindal, B.

    1992-01-01

    Industrial washing operation using geothermal water in Iceland are reported and testing designed to explain the beneficial effect of geothermal water for washing described. The findings indicate, that the silica content of the water may be the principal component for a superior washing quality

  9. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow.

    Science.gov (United States)

    Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T

    2018-01-01

    New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.

  10. Car wash wastewater treatment and water reuse - a case study.

    Science.gov (United States)

    Zaneti, R N; Etchepare, R; Rubio, J

    2013-01-01

    Recent features of a car wash wastewater reclamation system and results from a full-scale car wash wastewater treatment and recycling process are reported. This upcoming technology comprises a new flocculation-column flotation process, sand filtration, and a final chlorination. A water usage and savings audit (22 weeks) showed that almost 70% reclamation was possible, and fewer than 40 L of fresh water per wash were needed. Wastewater and reclaimed water were characterized by monitoring chemical, physicochemical and biological parameters. Results were discussed in terms of aesthetic quality (water clarification and odour), health (pathological) and chemical (corrosion and scaling) risks. A microbiological risk model was applied and the Escherichia coli proposed criterion for car wash reclaimed water is 200 CFU 100 mL(-1). It is believed that the discussions on car wash wastewater reclamation criteria may assist institutions to create laws in Brazil and elsewhere.

  11. Effects of shampoo and water washing on hair cortisol concentrations.

    Science.gov (United States)

    Hamel, Amanda F; Meyer, Jerrold S; Henchey, Elizabeth; Dettmer, Amanda M; Suomi, Stephen J; Novak, Melinda A

    2011-01-30

    Measurement of cortisol in hair is an emerging biomarker for chronic stress in human and nonhuman primates. Currently unknown, however, is the extent of potential cortisol loss from hair that has been repeatedly exposed to shampoo and/or water. Pooled hair samples from 20 rhesus monkeys were subjected to five treatment conditions: 10, 20, or 30 shampoo washes, 20 water-only washes, or a no-wash control. For each wash, hair was exposed to a dilute shampoo solution or tap water for 45 s, rinsed 4 times with tap water, and rapidly dried. Samples were then processed for cortisol extraction and analysis using previously published methods. Hair cortisol levels were significantly reduced by washing, with an inverse relationship between number of shampoo washes and the cortisol concentration. This effect was mainly due to water exposure, as cortisol levels following 20 water-only washes were similar to those following 20 shampoo treatments. Repeated exposure to water with or without shampoo appears to leach cortisol from hair, yielding values that underestimate the amount of chronic hormone deposition within the shaft. Collecting samples proximal to the scalp and obtaining hair washing frequency data may be valuable when conducting human hair cortisol studies. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Aqueous treatment of water-sensitive paper objects: capillary unit, blotter wash or paraprint wash?

    NARCIS (Netherlands)

    Schalkx, H.; Iedema, P.; Reissland, B.; van Velzen, B.

    2011-01-01

    Blotter washing andwashing with the capillary unit are both methods used for aqueoustreatment of water-sensitive paper objects. The challenge of thistreatment is to remove water-soluble products while keeping thewater-sensitive medium in its place. In this article the two methodsare compared, along

  13. Hygienic status assessment of dish washing waters, utensils, hands ...

    African Journals Online (AJOL)

    Hygienic status assessment of dish washing waters, utensils, hands and pieces of money from street food processing sites in Ouagadougou (Burkina Faso). N Barro, AR Bello, A Savadogo, CAT Ouattara, AJ Iiboudo, AS Traoré ...

  14. Effects of soap-water wash on human epidermal penetration.

    Science.gov (United States)

    Zhu, Hanjiang; Jung, Eui-Chang; Phuong, Christina; Hui, Xiaoying; Maibach, Howard

    2016-08-01

    Skin decontamination is a primary interventional method used to decrease dermal absorption of hazardous contaminants, including chemical warfare agents, pesticides and industrial pollutants. Soap and water wash, the most common and readily available decontamination system, may enhance percutaneous absorption through the "wash-in effect." To understand better the effect of soap-water wash on percutaneous penetration, and provide insight to improving skin decontamination methods, in vitro human epidermal penetration rates of four C(14) -labeled model chemicals (hydroquinone, clonidine, benzoic acid and paraoxon) were assayed using flow-through diffusion cells. Stratum corneum (SC) absorption rates of these chemicals at various hydration levels (0-295% of the dry SC weights) were determined and compared with the results of the epidermal penetration study to clarify the effect of SC hydration on skin permeability. Results showed accelerated penetration curves of benzoic acid and paraoxon after surface wash at 30 min postdosing. Thirty minutes after washing (60 min postdosing), penetration rates of hydroquinone and benzoic acid decreased due to reduced amounts of chemical on the skin surface and in the SC. At the end of the experiment (90 min postdosing), a soap-water wash resulted in lower hydroquinone penetration, greater paraoxon penetration and similar levels of benzoic acid and clonidine penetration compared to penetration levels in the non-wash groups. The observed wash-in effect agrees with the enhancement effect of SC hydration on the SC chemical absorption rate. These results suggest SC hydration derived from surface wash to be one cause of the wash-in effect. Further, the occurrence of a wash-in effect is dependent on chemical identity and elapsed time between exposure and onset of decontamination. By reducing chemical residue quantity on skin surface and in the SC reservoir, the soap-water wash may decrease the total quantity of chemical absorbed in the

  15. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow

    OpenAIRE

    Fogt JS; Jones-Jordan LA; Barr JT

    2018-01-01

    Jennifer S Fogt, Lisa A Jones-Jordan, Joseph T Barr The Ohio State University College of Optometry, Columbus, OH, USA Introduction: New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Materials ...

  16. New potentional of high-speed water jet technology for renovating concrete structures

    Science.gov (United States)

    Bodnárová, L.; Sitek, L.; Hela, R.; Foldyna, J.

    2011-06-01

    The paper discusses the background and results of research focused on the action of a high-speed water jet on concrete with different qualities. The sufficient and careful removal of degraded concrete layers is very important for the renovation of concrete structures. High-speed water jet technology is one of the most common methods used for removing degraded concrete layers. Different types of high-speed water jets were tested in the experimental part. The classical technology of a single continuous water jet generated with one nozzle was tested as well as the technology of revolving water jets generated by multiple nozzles (used mainly for the renovation of larger areas). A continuous flat water jet and pulsating flat water jet were tested the first time, because the connection of a water jet with the acoustic generator of a pulsating jet offers new possibilities for the use of a water jet (see [1] and [2]). A water jet with such a modification is capable of efficient action and can even be used for cutting solid concrete with a relatively low consumption of energy. A flat pulsating water jet which can be newly used for renovation seems to be a promising technology.

  17. Cross contamination of Escherichia coli O157:H7 between lettuce and wash water during home-scale washing.

    Science.gov (United States)

    Jensen, Dane A; Friedrich, Loretta M; Harris, Linda J; Danyluk, Michelle D; Schaffner, Donald W

    2015-04-01

    Lettuce and leafy greens have been implicated in multiple foodborne disease outbreaks. This study quantifies cross contamination between lettuce pieces in a small-scale home environment. A five-strain cocktail of relevant Escherichia coli O157:H7 strains was used. Bacterial transfer between single inoculated lettuce leaf pieces to 10 non-inoculated lettuce leaf pieces that were washed in a stainless steel bowl of water for 30 s, 1 min, 2 min, and 5 min was quantified. Regardless of washing time, the wash water became contaminated with 90-99% of bacteria originally present on the inoculated lettuce leaf piece. The E. coli O157:H7 concentration on initially inoculated leaf pieces was reduced ∼ 2 log CFU. Each initially uncontaminated lettuce leaf piece had ∼ 1% of the E. coli O157:H7 from the inoculated lettuce piece transferred to it after washing, with more transfer occurring during the shortest (30 s) and longest (5 min) wash times. In all cases the log percent transfer rates were essentially normally distributed. In all scenarios, most of the E. coli O157:H7 (90-99%) transferred from the inoculated lettuce pieces to the wash water. Washing with plain tap water reduces levels of E. coli O157:H7 on the inoculated lettuce leaf pieces, but also spreads contamination to previously uncontaminated leaf pieces. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    NARCIS (Netherlands)

    Banach, J.L.; Sampers, I.; Haute, van S.; Fels, van der H.J.

    2015-01-01

    The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water

  19. Water saving in IC wafer washing process; IC wafer senjo deno sessui taisaku

    Energy Technology Data Exchange (ETDEWEB)

    Harada, H. [Mitsubishi Corp., Tokyo (Japan); Araki, M.; Nakazawa, T.

    1997-11-30

    This paper reports features of a wafer washing technology, a new IC wafer washing process, its pure water saving effect, and a `QC washing` which has pure water saving effect in the wafer washing. Wafer washing processes generally include the SC1 process (using ammonia + hydrogen peroxide aqueous solution) purposed for removing contamination due to ultrafine particles, the SC2 process (using hydrochloric acid + hydrogen peroxide aqueous solution) purposed for removing contamination due to heavy metals, the piranha washing process (using hot sulfuric acid + hydrogen peroxide aqueous solution) purposed for removing contamination due to organic matters, and the DHF (using dilute hydrofluoric acid) purposed for removing natural oxide films. Natural oxide films are now remained as surface protection films, by which surface contamination has been reduced remarkably. A high-temperature washing chemical circulating and filtering technology developed in Japan has brought about a reform in wafer washing processes having been used previously. Spin washing is used as a water saving measure, in which washing chemicals or pure water are sprayed onto one each of wafers which is spin-rotated, allowing washing and rinsing to be made with small amount of washing chemicals and pure water. The QC washing is a method to replace tank interior with pure was as quick as possible in order to increase the rinsing effect. 7 refs., 5 figs.

  20. Evaluation of Water Quality Renovation by Advanced Soil-Based Wastewater Treatment Systems

    Science.gov (United States)

    Cooper, J.; Loomis, G.; Kalen, D.; Boving, T.; Morales, I.; DeLuca, J.; Amador, J.

    2013-12-01

    25% of US households utilize onsite wastewater treatment systems (OWTS) for wastewater management. Advanced technologies were designed to overcome the inadequate wastewater treatment by conventional OWTS in critical shallow water table areas, such as coastal zones, in order to protect ground water quality. In addition to the septic tank and soil drainfield that comprise a conventional OWTS, advanced systems claim improved water renovation with the addition of sand filtration, timed dosing controls, and shallow placement of the infiltrative zone. We determined water quality renovation functions under current water table and temperature conditions, in anticipation of an experiment to measure OWTS response to a climate change scenario of 30-cm increase in water table elevation and 4C temperature increase. Replicate (n=3) intact soil mesocosms were used to evaluate the effectiveness of drainfields with a conventional wastewater delivery (pipe-and-stone) compared to two types of pressurized, shallow narrow drainfield. Results under steady state conditions indicate complete removal of fecal coliform bacteria, phosphorus and BOD by all soil-based systems. By contrast, removal of total nitrogen inputs was 16% in conventional and 11% for both advanced drainfields. Effluent waters maintained a steady state pH between 3.2 - 3.7 for all technologies. Average DO readings were 2.9mg/L for conventional drainfield effluent and 4.6mg/L for advanced, showing the expected oxygen uptake with shallow placement of the infiltrative zone. The conventional OWTS is outperforming the advanced with respect to nitrogen removal, but renovating wastewater equivalently for all other contaminants of concern. The results of this study are expected to facilitate development of future OWTS regulation and planning guidelines, particularly in coastal zones and in the face of a changing climate.

  1. EBR-II Primary Tank Wash-Water Alternatives Evaluation

    International Nuclear Information System (INIS)

    Demmer, R.; Heintzelman, J.; Squires, L.; Meservey, R.

    2009-01-01

    The EBR-II reactor at Idaho National Laboratory was a liquid sodium metal cooled reactor that operated for 30 years. Approximately 1100 kg of residual sodium remained in the primary system after draining the bulk sodium. To stabilize the remaining sodium, both the primary and secondary systems were treated with a purge of moist carbon dioxide. The passivation treatment was stopped in 2005 and the primary system is maintained under a blanket of dry carbon dioxide. Approximately 670 kg of sodium metal remains in the primary system in locations that were inaccessible to passivation treatment or in pools of sodium that were too deep for complete penetration of the passivation treatment. The EBR-II reactor was permitted by the Idaho Department of Environmental Quality (DEQ) in 2002 under a RCRA permit that requires removal of all remaining sodium. The proposed baseline closure method would remove the large components from the primary tank, fill the primary system with water, react the remaining sodium with the water and dissolve the reaction products in about 100,000 gallons of wash water. On February 19-20, 2008, a workshop was held in Idaho Falls, Idaho, to evaluate alternatives that could meet the RCRA permit clean closure requirements and minimize the quantity of hazardous waste generated by the cleanup process. The workshop convened a panel of national and international sodium cleanup specialists, subject matter experts from the INL, and the EBR-II Wash Water Project team that organized the workshop. The workshop was conducted by a trained facilitator using Value Engineering techniques to elicit the most technically sound solutions from the workshop participants. A brainstorming session was held to identify possible alternative treatment methods that would meet the primary functions and criteria of neutralizing the hazards, maximizing byproduct removal and minimizing waste generation. An initial list of some 20 probable alternatives was evaluated and refined down

  2. Check experiment of the high pressure water washing technology used to the decommissioning of reactor

    International Nuclear Information System (INIS)

    Han Jianping; Hou Yongming; Fu Yunshan

    2004-01-01

    High pressure water washing technology has been widely applied in the field of the decommissioning of nuclear facilities, and it is used to wash the sump for craft conveyance, the craft workshop, the hermetic sump, and some other nuclear equipment as well. The authors have got a set of technical data correlated with high pressure water washing technology by comparing the situations between the test before and after the washing work. At the same time, authors also improve the technique on some special cases, which made the high pressure water washing technology more perfect in the field of the decommissioning of nuclear facilities. (authors)

  3. Enhanced salmonella reduction on tomatoes washed in chlorinated water with wash aid T-128

    Science.gov (United States)

    Chlorine is widely used by the fresh and fresh-cut produce industries to reduce microbial populations and to prevent potential pathogen cross contamination during produce washing. However, the organic materials released from produce quickly react with chlorine and degrade its efficacy for pathogen i...

  4. Reverse osmosis for wash water recovery in space vehicles.

    Science.gov (United States)

    Lawrence, R. W.; Saltonstall, C. W., Jr.

    1973-01-01

    Tests were carried out on both synthetic and real wash water derived from clothes laundry to determine the utility of reverse osmosis in recovering the water for recycle use. A blend membrane made from cellulose di- and triacetates, and a cross-linked cellulose acetate/methacrylate were evaluated. Both were found acceptable. A number of detergents were evaluated, including a cationic detergent, sodium dodecyl sulfate, potassium palmitate, and sodium dodecylbenzenesulfonate. The tests were all made at a temperature of 165 F to minimize microbial growth. Long-term (15 to 30 day) runs were made at 600 and 400 psi on laundry water which was pretreated either by alum addition and sand filtration or by filtration only through 0.5 micron filters. A 30-day run was made using a 2-in. diameter by 22-in. long spiral module at 400 psig with filtering as the pretreatment. The membrane fouling by colloidal matter was found to be controllable. The unit produced initially 55 gal/day and 27 gal/day after 30 days.

  5. EBR-II Primary Tank Wash-Water Alternatives Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Demmer, R. L.; Heintzelman, J. B.; Merservey, R. H.; Squires, L. N.

    2008-05-01

    The EBR-II reactor at Idaho National Laboratory was a liquid sodium metal cooled reactor that operated for 30 years. It was shut down in 1994; the fuel was removed by 1996; and the bulk of sodium metal coolant was removed from the reactor by 2001. Approximately 1100 kg of residual sodium remained in the primary system after draining the bulk sodium. To stabilize the remaining sodium, both the primary and secondary systems were treated with a purge of moist carbon dioxide. Most of the residual sodium reacted with the carbon dioxide and water vapor to form a passivation layer of primarily sodium bicarbonate. The passivation treatment was stopped in 2005 and the primary system is maintained under a blanket of dry carbon dioxide. Approximately 670 kg of sodium metal remains in the primary system in locations that were inaccessible to passivation treatment or in pools of sodium that were too deep for complete penetration of the passivation treatment. The EBR-II reactor was permitted by the Idaho Department of Environmental Quality (DEQ) in 2002 under a RCRA permit that requires removal of all remaining sodium in the primary and secondary systems by 2022. The proposed baseline closure method would remove the large components from the primary tank, fill the primary system with water, react the remaining sodium with the water and dissolve the reaction products in the wash water. This method would generate a minimum of 100,000 gallons of caustic, liquid, low level radioactive, hazardous waste water that must be disposed of in a permitted facility. On February 19-20, 2008, a workshop was held in Idaho Falls, Idaho, to look at alternatives that could meet the RCRA permit clean closure requirements and minimize the quantity of hazardous waste generated by the cleanup process. The workshop convened a panel of national and international sodium cleanup specialists, subject matter experts from the INL, and the EBR-II Wash Water Project team that organized the workshop. The

  6. Domestic wash water reclamation for reuse as commode water supply using filtration: Reverse-osmosis separation technique

    Science.gov (United States)

    Hall, J. B., Jr.; Batten, C. E.; Wilkins, J. R.

    1974-01-01

    A combined filtration-reverse-osmosis water recovery system has been evaluated to determine its capability to reclaim domestic wash water for reuse as a commode water supply. The system produced water that met all chemical and physical requirements established by the U.S. Public Health Service for drinking water with the exception of carbon chloroform extractables, methylene blue active substances, and phenols. It is thought that this water is of sufficient quality to be reused as commode supply water. The feasibility of using a combined filtration and reverse-osmosis technique for reclaiming domestic wash water has been established. The use of such a technique for wash-water recovery will require a maintenance filter to remove solid materials including those less than 1 micron in size from the wash water. The reverse-osmosis module, if sufficiently protected from plugging, is an attractive low-energy technique for removing contaminants from domestic wash water.

  7. Water usage characteristics of car wash facilities in Ortahisar district of Trabzon province

    OpenAIRE

    Karabacak, Volkan; Topbaş, Murat; Karakullukçu, Serdar; Demirtaş, Yusuf; Çankaya, Sertaç; Çan, Gamze; Beyhun, N. Ercüment

    2018-01-01

    Introduction. Water management is ontop of the agenda for all countries Aimof the study. The aim of this study was to determine the water usage in thecar wash facilities of Ortahisar district of Trabzon province, such as thefeatures of the water used in drinking and car washing, the disposal ofwastewater and case of water interruption situation in the facilities. Material and methods. This descriptivestudy was conducted in Ortahisar district of Trabzon province. The studypopulation of the res...

  8. The influence of prefabricated pipe cement coatings and those made during pipe renovation on drinking water quality

    OpenAIRE

    Młyńska Anna; Zielina Michał

    2017-01-01

    Nowadays, cement coatings are often used as an anticorrosion protection of the internal surfaces of manufactured ductile iron water pipes. The protective cement linings are also commonly used for old water pipe renovation. In both cases, the cement lining is an excellent anticorrosion protection of the pipelines, effectively separating the pipe wall from the flowing water. Moreover, cement linings protect the pipelines not only by a mechanical barrier, but also by a chemical barrier creating ...

  9. Water washes and caustic leaches of sludge from Hanford Tank S-101 and water washes of sludge from Hanford Tank C-103

    International Nuclear Information System (INIS)

    Hunt, R.D.; Collins, J.L.; Chase, C.W.

    1998-07-01

    In 1993, the Department of Energy (DOE) selected the enhanced sludge washing (ESW) process as the baseline for pretreatment of Hanford tank sludges. The ESW process uses a series of water washes and caustic leaches to separate nonradioactive components such as aluminum, chromium, and phosphate from the high-level waste sludges. If the ESW process is successful, the volume of immobilized high-level waste will be significantly reduced. The tests on the sludge from Hanford Tank S-101 focused on the effects of process variables such as sodium hydroxide concentration (1 and 3 M), temperature (70 and 95 C), and leaching time (5, 24, 72, and 168 h) on the efficacy of the ESW process with realistic liquid-to-solid ratios. Another goal of this study was to evaluate the effectiveness of water washes on a sludge sample from hanford Tank C-103. The final objective of this study was to test potential process control monitors during the water washes and caustic leaches with actual sludge. Both 137 Cs activity and conductance were measured for each of the water washes and caustic leaches. Experimental procedures, a discussion of results, conclusions and recommendations are included in this report

  10. Washing Habits and Machine with Intake of hot and cold Water

    DEFF Research Database (Denmark)

    Christensen, Bente Lis; Nørgaard, Jørgen

    1997-01-01

    with slightly adapted washing habits, or 17% of normal today. If the heat is supplied from combined heat and power production as in the actual experiment, CO2-emission is reduced by 81%. With hot water from oil or gas heaters the reduction will be slightly lower, while with solar hot water it will be larger.......Domestic washing machines typically spend around 80% of the electricity on heating water. Most of this can be replaced by more appropriate heat sources like district heat from combined heat and power production, or gas heating system. In recent years some washing machine manufacturers have marketed...... machines which can take in both hot and cold water and mix it to the temperature wanted. Such one machine has been tested in daily household use over 5 months, with habits of very few hot water washes. The result is an electricity consumption corresponding to 67 kWh per year for an average household...

  11. Winter Maintenance Wash-Water Heavy Metal Removal Pilot Scale Evaluation

    Directory of Open Access Journals (Sweden)

    Christopher M. Miller

    2016-01-01

    Full Text Available To encourage sustainable engineering practices, departments of transportation are interested in reusing winter maintenance truck wash water as part of their brine production and future road application. Traffic-related metals in the wash water, however, could limit this option. The objective of this work was to conduct a pilot scale evaluation of heavy metal (copper, zinc, iron, and lead removal in a filtration unit (maximum flow rate of 45 L/minute containing proprietary (MAR Systems Sorbster® media. Three different trials were conducted and approximately 10,000 L of wash water collected from a winter maintenance facility in Ohio was treated with the pilot unit. Lab studies were also performed on six wash-water samples from multiple facilities to assess particle size removal and estimate settling time as a potential removal mechanism during wash-water storage. Pilot unit total metal removal efficiencies were 79%, 77%, 63%, and 94% for copper, zinc, iron, and lead, respectively. Particle settling calculation estimates for copper and zinc show that 10 hours in storage can also effectively reduce heavy metal concentrations in winter maintenance wash water in excess of 70%. These pilot scale results show promise for reducing heavy metal concentrations to an acceptable level for reuse.

  12. Treatment techniques for the recycling of bottle washing water in the soft drinks industry.

    Science.gov (United States)

    Ramirez Camperos, E; Mijaylova Nacheva, P; Diaz Tapia, E

    2004-01-01

    The soft drink production is an important sector in the manufacturing industry of Mexico. Water is the main source in the production of soft drinks. Wastewater from bottle washing is almost 50% of the total wastewater generated by this industry. In order to reduce the consumption of water, the water of the last bottle rinse can be reused in to the bottle pre-rinse and pre-washing cycles. This work presents the characterization of the final bottle washing rinse discharge and the treatability study for the most appropriate treatment system for recycling. Average characteristics of the final bottle wash rinse were as follows: Turbidity 40.46 NTU, COD 47.7 mg/L, TSS 56 mg/L, TS 693.6 mg/L, electrical conductivity 1,194 microS/cm. The results of the treatability tests showed that the final rinse water can be used in the pre-rinse and pre-washing after removing the totality of the suspended solids, 80% of the COD and 75% of the dissolved solids. This can be done using the following treatment systems: filtration-adsorption-reverse osmosis, or filtration-adsorption-ion exchange. The installation of these treatment techniques in the soft drink industry would decrease bottle washing water consumption by 50%.

  13. Estimated ground-water recharge from streamflow in Fortymile Wash near Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Savard, C.S.

    1998-01-01

    The two purposes of this report are to qualitatively document ground-water recharge from stream-flow in Fortymile Wash during the period 1969--95 from previously unpublished ground-water levels in boreholes in Fortymile Canyon during 1982--91 and 1995, and to quantitatively estimate the long-term ground-water recharge rate from streamflow in Fortymile Wash for four reaches of Fortymile Wash (Fortymile Canyon, upper Jackass Flats, lower Jackass Flats, and Amargosa Desert). The long-term groundwater recharge rate was estimated from estimates of the volume of water available for infiltration, the volume of infiltration losses from streamflow, the ground-water recharge volume from infiltration losses, and an analysis of the different periods of data availability. The volume of water available for infiltration and ground-water recharge in the four reaches was estimated from known streamflow in ephemeral Fortymile Wash, which was measured at several gaging station locations. The volume of infiltration losses from streamflow for the four reaches was estimated from a streamflow volume loss factor applied to the estimated streamflows. the ground-water recharge volume was estimated from a linear relation between infiltration loss volume and ground-water recharge volume for each of the four reaches. Ground-water recharge rates were estimated for three different periods of data availability (1969--95, 1983--95, and 1992--95) and a long-term ground-water recharge rate estimated for each of the four reaches

  14. Estimated ground-water recharge from streamflow in Fortymile Wash near Yucca Mountain, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Savard, C.S.

    1998-10-01

    The two purposes of this report are to qualitatively document ground-water recharge from stream-flow in Fortymile Wash during the period 1969--95 from previously unpublished ground-water levels in boreholes in Fortymile Canyon during 1982--91 and 1995, and to quantitatively estimate the long-term ground-water recharge rate from streamflow in Fortymile Wash for four reaches of Fortymile Wash (Fortymile Canyon, upper Jackass Flats, lower Jackass Flats, and Amargosa Desert). The long-term groundwater recharge rate was estimated from estimates of the volume of water available for infiltration, the volume of infiltration losses from streamflow, the ground-water recharge volume from infiltration losses, and an analysis of the different periods of data availability. The volume of water available for infiltration and ground-water recharge in the four reaches was estimated from known streamflow in ephemeral Fortymile Wash, which was measured at several gaging station locations. The volume of infiltration losses from streamflow for the four reaches was estimated from a streamflow volume loss factor applied to the estimated streamflows. the ground-water recharge volume was estimated from a linear relation between infiltration loss volume and ground-water recharge volume for each of the four reaches. Ground-water recharge rates were estimated for three different periods of data availability (1969--95, 1983--95, and 1992--95) and a long-term ground-water recharge rate estimated for each of the four reaches.

  15. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    Science.gov (United States)

    Banach, Jennifer L.; Sampers, Imca; Van Haute, Sam; van der Fels-Klerx, H.J. (Ine)

    2015-01-01

    The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water disinfectants during produce processing with the aim to prevent cross-contamination of pathogens. Process wash water disinfection requires short contact times so microorganisms are rapidly inactivated. Free chlorine, chlorine dioxide, ozone, and peracetic acid were considered suitable disinfectants. A disinfectant’s reactivity with the organic matter will determine the disinfectant residual, which is of paramount importance for microbial inactivation and should be monitored in situ. Furthermore, the chemical and worker safety, and the legislative framework will determine the suitability of a disinfection technique. Current research often focuses on produce decontamination and to a lesser extent on preventing cross-contamination. Further research on a sanitizer’s efficacy in the washing water is recommended at the laboratory scale, in particular with experimental designs reflecting industrial conditions. Validation on the industrial scale is warranted to better understand the overall effects of a sanitizer. PMID:26213953

  16. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    Directory of Open Access Journals (Sweden)

    Jennifer L. Banach

    2015-07-01

    Full Text Available The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water disinfectants during produce processing with the aim to prevent cross-contamination of pathogens. Process wash water disinfection requires short contact times so microorganisms are rapidly inactivated. Free chlorine, chlorine dioxide, ozone, and peracetic acid were considered suitable disinfectants. A disinfectant’s reactivity with the organic matter will determine the disinfectant residual, which is of paramount importance for microbial inactivation and should be monitored in situ. Furthermore, the chemical and worker safety, and the legislative framework will determine the suitability of a disinfection technique. Current research often focuses on produce decontamination and to a lesser extent on preventing cross-contamination. Further research on a sanitizer’s efficacy in the washing water is recommended at the laboratory scale, in particular with experimental designs reflecting industrial conditions. Validation on the industrial scale is warranted to better understand the overall effects of a sanitizer.

  17. Nasal Wash Treatment

    Science.gov (United States)

    ... Medications Alternative Therapies Nasal Wash Treatment Nasal Wash Treatment Make an Appointment Ask a Question Refer Patient The Centers for Disease Control (CDC) guidelines for preparing water used in a nasal wash are listed below. Many ...

  18. Evaluation of different water-washing treatments effects on wheat straw combustion properties.

    Science.gov (United States)

    Ma, Qiulin; Han, Lujia; Huang, Guangqun

    2017-12-01

    A series of experiments was conducted to explore the effects of various water-washing solid-liquid ratios (1:50 and 1:10) and the stirring on wheat straw (WS) combustion properties. Comparing different solid-liquid ratio groups, a 16% increment in the higher heating value was obtained for 1:50 groups and only 5% for 1:10 groups relative to the raw material. Moreover, energy was lost 4-26 times greater in 1:10 groups than 1:50 groups. While water-washing reduced the comprehensive combustibility index by 14.89%-32.09%, the index values of washed WS were all higher than 2, indicating good combustion performance. The combustion activation energy of four washed WS were 175, 172, 186, and 176kJ/mol, which were all higher than the 160kJ/mol of WS. The fouling/slagging propensity of washed WS reduced to a lower possibility compared to medium of untreated WS. Overall, the recommended condition for washing WS before combustion is 1:50 ratio without stirring. Copyright © 2017. Published by Elsevier Ltd.

  19. The influence of prefabricated pipe cement coatings and those made during pipe renovation on drinking water quality

    Directory of Open Access Journals (Sweden)

    Młyńska Anna

    2017-01-01

    Full Text Available Nowadays, cement coatings are often used as an anticorrosion protection of the internal surfaces of manufactured ductile iron water pipes. The protective cement linings are also commonly used for old water pipe renovation. In both cases, the cement lining is an excellent anticorrosion protection of the pipelines, effectively separating the pipe wall from the flowing water. Moreover, cement linings protect the pipelines not only by a mechanical barrier, but also by a chemical barrier creating a highly alkaline environment in water contact with the metal pipe wall. In addition, cement coatings have an ability for so-called self-regeneration and provide the improvement of hydraulic conditions inside the pipelines. In turn, the differences between the analysed cement coatings mainly depend on the types of cements used and techniques of cement mortar spraying. As was expected, they influence the quality of water having contact with the coating. A comparison of the impact of cement coatings manufactured in factories and sprayed on building sites during the renovation on drinking water quality parameters was performed in the study. The experiments were conducted in laboratory conditions, using the test stands prepared for this purpose. The results include analysis of selected water quality parameters for the samples contacting with cement mortar and collected during the investigation.

  20. Recovery And Valorization Of Snakehead Fish Channa Striata Surimi Wash Water As Stock Albumin Tablet

    Directory of Open Access Journals (Sweden)

    Ikbal Syukroni

    2017-11-01

    Full Text Available Surimi washing process is aimed to concentrate the myofibril protein by removing catepsin enzyme fat pigment blood and sarcoplasmic protein which is soluble in wash water. The soluble subtances cause trouble environment if it was untreated. In addition recovery protein will give benefit both in reducing trouble environment and utilizing soluble protein as sources of albumin protein. The objectives of research were to recover albumin from snakehead fish surimi wash water and to valorize as stock albumin tablet. Recovery of albumin use 0.05 m ultrafiltration membrane and the valorization of albumin tablets was by direct compression. The protein band with molecular weight of 67.741 kDa on the retentate was detected as albumin. Concentration of protein recover by ultrafiltration membrane increased 89.98 and the albumin content 3.50.4 gdl. Based on the result of chemical composition and microbiology analysis albumin of snakehead surimi wash water appropriate with Indonesia National Standard SNI quality requirement about snakehead fish albumin extract. The best formulation in the preparation of surimi wash water albumin tablet was by using corn starch excipients with uniformity weight value 410.39 0.09 g hardness value 7.65 0.8 Kp uniformity size of tablet with diameter 1 cm and thickness 0.59 cm friability value 2.3 and disintregation time of the tablet is 2 minutes 16 second.

  1. Renovating process for Pressurized Water Reactor control rod assemblies and corresponding control

    International Nuclear Information System (INIS)

    Jahnke, S.; Ple, P.

    1989-01-01

    In the first PWRs the control rods are moving by the intermediary of electromagnetic mechanisms where the power fed to the electromagnets is selected by a hard wired logic circuit connected to the controldesh by another logic control. For renovating the control rod assemblies each power assembly is replaced by an electronic assembly containing an ordinator and power supply interfaces [fr

  2. A novel reverse-osmosis wash water recycle system for manned space stations

    Science.gov (United States)

    Ray, R. J.; Babcock, W. C.; Barss, R. P.; Andrews, T. A.; Lachapelle, E. D.

    1984-01-01

    The preliminary development of a wash water recycle system utilizing an inside-skinned hollow-fiber membrane is described. This module configuration is based on tube-side feed and is highly resistant to fouling with a minimum of pretreatment. During an ongoing research program for NASA, these modules were operated on actual wash waters with no significant fouling for a period of 40 days. Due to the tube-side-feed flow in these hollow-fiber membranes, the fibers themselves become the pressure vessels, allowing the development of extremely lightweight membrane modules. During the NASA research program, a pre-prototype membrane module capable of processing 6 gallons per day of wash water at 97 percent recovery was developed that can be dry-stored and that weighs 120 g.

  3. RESOLUTION OF THE PROBLEM OF TREATMENT OF WASTE WATER GENERATED BY CAR WASHES AND TRANSPORT ENTERPRISES

    Directory of Open Access Journals (Sweden)

    Gogina Elena Sergeevna

    2012-12-01

    big cities of Russia. At the same time, the quality of the waste water treated by local water treatment stations fails to meet the present-day standard requirements. Moreover, potable water shall not be used for the purpose of washing transport vehicles. Within the recent 10 years, MGSU has developed a number of research projects aimed at the resolution of this problem. The concept developed by the MGSU specialists is to attain the highest quality of treated waste water generated by car washes and transport enterprises using the most advanced technologies of water treatment rather than to design new water treatment plants. Various methods may be applied for this purpose: restructuring of water treatment facilities, advanced feed, updated regulations governing the operation of water treatment plants.

  4. Exploratory Disposal and Reuse Feasibility Analysis of Winter Maintenance Wash Water.

    Science.gov (United States)

    Ullinger, Heather L; Kennedy, Marla J; Schneider, William H; Miller, Christopher M

    2016-01-01

    The Ohio Department of Transportation has more than 60 facilities without sewer access generating approximately 19 million gallons of winter maintenance wash water. Off-site disposal is costly, creating the need for sustainable management strategies. The objective of this study was to conduct an exploratory feasibility analysis to assess wash water disposal and potential reuse as brine. Based on a comprehensive literature review and relevant environmental chemistry, a sampling protocol consisting of 31 water quality constituents was utilized for monthly sampling at three geographically distinct Ohio Department of Transportation garages during the winter of 2012. Results were compared to local disposal and reuse guidance limits. Three constituents, including a maximum copper concentration of 858 ppb, exceeded disposal limits, and many constituents also failed to meet reuse limits. Some concentrations were orders of magnitude higher than reuse limits and suggest pre-treatment would be necessary if wash water were reused as brine. These water quality results, in conjunction with copper chemical equilibrium modeling, show pH and dissolved carbon both significantly impact the total dissolved copper concentration and should be measured to assess reuse potential. The sampling protocol and specific obstacles highlighted in this paper aid in the future development of sustainable wash water management strategies.

  5. Exploratory Disposal and Reuse Feasibility Analysis of Winter Maintenance Wash Water.

    Directory of Open Access Journals (Sweden)

    Heather L Ullinger

    Full Text Available The Ohio Department of Transportation has more than 60 facilities without sewer access generating approximately 19 million gallons of winter maintenance wash water. Off-site disposal is costly, creating the need for sustainable management strategies. The objective of this study was to conduct an exploratory feasibility analysis to assess wash water disposal and potential reuse as brine. Based on a comprehensive literature review and relevant environmental chemistry, a sampling protocol consisting of 31 water quality constituents was utilized for monthly sampling at three geographically distinct Ohio Department of Transportation garages during the winter of 2012. Results were compared to local disposal and reuse guidance limits. Three constituents, including a maximum copper concentration of 858 ppb, exceeded disposal limits, and many constituents also failed to meet reuse limits. Some concentrations were orders of magnitude higher than reuse limits and suggest pre-treatment would be necessary if wash water were reused as brine. These water quality results, in conjunction with copper chemical equilibrium modeling, show pH and dissolved carbon both significantly impact the total dissolved copper concentration and should be measured to assess reuse potential. The sampling protocol and specific obstacles highlighted in this paper aid in the future development of sustainable wash water management strategies.

  6. Sequential Washing with Electrolyzed Alkaline and Acidic Water Effectively Removes Pathogens from Metal Surfaces.

    Directory of Open Access Journals (Sweden)

    Yuichiro Nakano

    Full Text Available Removal of pathogenic organisms from reprocessed surgical instruments is essential to prevent iatrogenic infections. Some bacteria can make persistent biofilms on medical devices. Contamination of non-disposable equipment with prions also represents a serious risk to surgical patients. Efficient disinfection of prions from endoscopes and other instruments such as high-resolution cameras remains problematic because these instruments do not tolerate aggressive chemical or heat treatments. Herein, we develop a new washing system that uses both the alkaline and acidic water produced by electrolysis. Electrolyzed acidic water, containing HCl and HOCl as active substances, has been reported to be an effective disinfectant. A 0.15% NaCl solution was electrolyzed and used immediately to wash bio-contaminated stainless steel model systems with alkaline water (pH 11.9 with sonication, and then with acidic water (pH 2.7 without sonication. Two bacterial species (Staphylococcus aureus and Pseudomonas aeruginosa and a fungus (Candida albicans were effectively removed or inactivated by the washing process. In addition, this process effectively removed or inactivated prions from the stainless steel surfaces. This washing system will be potentially useful for the disinfection of clinical devices such as neuroendoscopes because electrolyzed water is gentle to both patients and equipment and is environmentally sound.

  7. WASH (Water and Sanitation for Health) Rainwater Information Center.

    Science.gov (United States)

    Campbell, D.

    1986-01-01

    Describes project funded by U.S. Agency for International Development to provide short-term technical assistance (general, technology transfer, institutional development and training, information support) to rural and urban fringe water supply and sanitation projects. Initial steps, special collection, and future components of rainwater network…

  8. Tailoring Water, Sanitation, and Hygiene (WASH) Targets for Soil-Transmitted Helminthiasis and Schistosomiasis Control.

    Science.gov (United States)

    Campbell, Suzy J; Biritwum, Nana-Kwadwo; Woods, Geordie; Velleman, Yael; Fleming, Fiona; Stothard, J Russell

    2018-01-01

    The World Health Organization's (WHO) 2015-2020 Global Strategy on water, sanitation, and hygiene (WASH) and neglected tropical diseases (NTDs) encourages integration, whilst maintaining existing structured NTD investments, and acceleration towards Sustainable Development Goal (SDG) targets. Accordingly, SDG-associated and WASH-NTD indicators have been developed, commencing important intersectoral dialogue, alongside opportunities for future disease-specific refinements. The rationale for soil-transmitted helminthiasis (STH)- and schistosomiasis-specific WASH considerations, and a traffic-light figure, are presented here to indicate where current international definitions may, or may not, suffice. Certain unique aspects in control dynamics and parasitic lifecycles, however, necessitate additional implementation research with more appropriate measurement indicators developed to record programmatic interventions and to define strategic priorities more effectively. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Assessing the effect of sodium dichloroisocyanurate concentration on transfer of Salmonella enterica serotype Typhimurium in wash water for production of minimally processed iceberg lettuce (Lactuca sativa L.).

    Science.gov (United States)

    Maffei, D F; Sant'Ana, A S; Monteiro, G; Schaffner, D W; Franco, B D G M

    2016-06-01

    This study evaluated the impact of sodium dichloroisocyanurate (5, 10, 20, 30, 40, 50 and 250 mg l(-1) ) in wash water on transfer of Salmonella Typhimurium from contaminated lettuce to wash water and then to other noncontaminated lettuces washed sequentially in the same water. Experiments were designed mimicking the conditions commonly seen in minimally processed vegetable (MPV) processing plants in Brazil. The scenarios were as follows: (1) Washing one inoculated lettuce portion in nonchlorinated water, followed by washing 10 noninoculated portions sequentially. (2) Washing one inoculated lettuce portion in chlorinated water followed by washing five noninoculated portions sequentially. (3) Washing five inoculated lettuce portions in chlorinated water sequentially, followed by washing five noninoculated portions sequentially. (4) Washing five noninoculated lettuce portions in chlorinated water sequentially, followed by washing five inoculated portions sequentially and then by washing five noninoculated portions sequentially in the same water. Salm. Typhimurium transfer from inoculated lettuce to wash water and further dissemination to noninoculated lettuces occurred when nonchlorinated water was used (scenario 1). When chlorinated water was used (scenarios 2, 3 and 4), no measurable Salm. Typhimurium transfer occurred if the sanitizer was ≥10 mg l(-1) . Use of sanitizers in correct concentrations is important to minimize the risk of microbial transfer during MPV washing. In this study, the impact of sodium dichloroisocyanurate in the wash water on transfer of Salmonella Typhimurium from inoculated lettuce to wash water and then to other noninoculated lettuces washed sequentially in the same water was evaluated. The use of chlorinated water, at concentration above 10 mg l(-1) , effectively prevented Salm. Typhimurium transfer under several different washing scenarios. Conversely, when nonchlorinated water was used, Salm. Typhimurium transfer occurred in

  10. Investigation of heterogeneous ice nucleation in pollen suspensions and washing water

    Science.gov (United States)

    Dreischmeier, Katharina; Budke, Carsten; Koop, Thomas

    2014-05-01

    Biological particles such as pollen often show ice nucleation activity at temperatures higher than -20 °C. Immersion freezing experiments of pollen washing water demonstrate comparable ice nucleation behaviour as water containing the whole pollen bodies (Pummer et al., 2012). It was suggested that polysaccharide molecules leached from the grains are responsible for the ice nucleation. Here, heterogeneous ice nucleation in birch pollen suspensions and their washing water was investigated by two different experimental methods. The optical freezing array BINARY (Bielefeld Ice Nucleation ARraY) allows the direct observation of freezing of microliter-sized droplets. The IN spectra obtained from such experiments with birch pollen suspensions over a large concentration range indicate several different ice nucleation active species, two of which are present also in the washing water. The latter was probed also in differential scanning calorimeter (DSC) experiments of emulsified sub-picoliter droplets. Due to the small droplet size in the emulsion samples and at small concentration of IN in the washing water, such DSC experiments can exhibit the ice nucleation behaviour of a single nucleus. The two heterogeneous freezing signals observed in the DSC thermograms can be assigned to two different kinds of ice nuclei, confirming the observation from the BINARY measurements, and also previous studies on Swedish birch pollen washing water (Augustin et al., 2012). The authors gratefully acknowledge funding by the German Research Foundation (DFG) through the project BIOCLOUDS (KO 2944/1-1) and through the research unit INUIT (FOR 1525) under KO 2944/2-1. We particularly thank our INUIT partners for fruitful collaboration and sharing of ideas and IN samples. S. Augustin, H. Wex, D. Niedermeier, B. Pummer, H. Grothe, S. Hartmann, L. Tomsche, T. Clauss, J. Voigtländer, K. Ignatius, and F. Stratmann, Immersion freezing of birch pollen washing water, Atmos. Chem. Phys., 13, 10989

  11. The Integrated Renovation Process

    DEFF Research Database (Denmark)

    Galiotto, Nicolas; Heiselberg, Per; Knudstrup, Mary-Ann

    The Integrated Renovation Process (IRP) is a user customized methodology based on judiciously selected constructivist and interactive multi-criteria decision making methods (Galiotto, Heiselberg, & Knudstrup, 2014 (expected)). When applied for home renovation, the Integrated Renovation Process...

  12. Renovate produced-water-treating facilities to handle increased water cuts

    International Nuclear Information System (INIS)

    Murti, D.G.K.; Al-Nuaimi, H.R.

    1991-01-01

    This paper reports on the modified skimmer tanks that have consistently demonstrated superior oil recovery characteristics compared to conventional design in an oil field tank battery system. The modified tanks have been in continuous service for more than 3 years in one of the oldest oil fields in the Arabian Gulf. The new design has helped recover skimmed oil from a mere 6 bpd (1.0 m 3 ) to more than 55 bpd (8.75 m 3 ) from produced water in a tank battery system alone. The recovery is expected to improve by up to 200 bpd (31.8 m 3 ) once skimmer tanks in all the tank batteries are upgraded to the new design

  13. Disinfection potential of ozone, ultraviolet-C and their combination in wash water for the fresh-cut vegetable industry.

    Science.gov (United States)

    Selma, María V; Allende, Ana; López-Gálvez, Francisco; Conesa, María A; Gil, María I

    2008-09-01

    The purpose of this research was to investigate the disinfection efficacy of ozone (O(3)) and UV-C illumination (UV), and their combination (O(3)-UV) for reducing microbial flora of fresh-cut onion, escarole, carrot, and spinach wash waters collected from the industry. Furthermore, the influence of water physicochemical parameters on the decontamination efficacy and the effect of these technologies on physicochemical quality of wash water were analyzed. O(3), UV, and O(3)-UV were effective disinfection treatments on vegetable wash water, with a maximum microbial reduction of 6.6 log CFU mL(-1) after 60 min treatment with O(3)-UV. However, maximum total microbial reductions achieved by UV and O(3) treatments after 60 min were 4.0 and 5.9 log CFU mL(-1), lower than by O(3)-UV treatment. Furthermore, turbidity of wash water was reduced significantly by O(3) and O(3)-UV treatments, while UV treatment did not affect the physicochemical quality of the water. Conclusions derived from this study illustrate that O(3) and O(3)-UV are alternatives to other sanitizers used in the fresh-cut washing processes. The use of these technologies would allow less frequent changing of spent water and the use of much lower sanitizer doses. Nevertheless, in specific applications such as carrot wash water, where levels of undesirable microbial and chemical constituents are lower than other vegetable wash water, UV treatment could be an appropriate treatment considering cost-effectiveness criteria.

  14. Performance of a Small-scale Treatment Wetland for Treatment of Landscaping Wash Water

    Science.gov (United States)

    Thompson, R. J.; Fayed, E.; Fish, W.

    2011-12-01

    A large number of lawn mowers and related equipment must be cleaned each day by commercial landscaping operations and state and local highway maintenance crews. Washing these devices produces wastewater that contains high amounts of organic matter and potentially problematic nutrients, as well as oil and grease and other chemicals and metals that come from the machinery itself. Dirty water washes off the mowers, flows off the pavement and into nearby storm drains without any kind of treatment. A better idea would be to collect such wastewater, retain it in an appropriate catchment such as an engineered wetland where natural processes could break down any pollutants in the wash water, and allow the water to naturally evaporate or percolate into the soil where it could recharge ground water resources safely. This research examines the performance of a small-scale treatment wetland tailored to remove nitrogen from landscaping wash water by incorporating both aerobic and anaerobic phases. Contaminants are analyzed through physical and chemical methods. Both methods involve collection of samples, followed by standardized, validated analytical laboratory tests for measuring total solids, total kjeldahl nitrogen, nitrates, total and dissolved phosphorus, COD, BOD, oil and grease, and metals (Zn and Cu). High levels of total solids, total kjeldahl nitrogen, nitrates, total and dissolved phosphorus, COD, BOD, oil and grease are found. Zinc and copper levels are low. Wetland treatment removes 99% total solids, 77% total kjeldahl nitrogen, 100% nitrates, 94% total phosphorus, 86% dissolved phosphorus, 94% COD, 97% BOD, and 76% oil and grease. The results will be a critical step towards developing a sustainable low-energy system for treating such wastewater that could be used by private landscaping companies and government agencies.

  15. Biodiesel production by two-stage transesterification with ethanol by washing with neutral water and water saturated with carbon dioxide.

    Science.gov (United States)

    Mendow, G; Veizaga, N S; Sánchez, B S; Querini, C A

    2012-08-01

    Industrial production of ethyl esters is impeded by difficulties in purifying the product due to high amounts of soap formed during transesterification. A simple biodiesel wash process was developed that allows successful purification of samples containing high amounts of soap. The key step was a first washing with neutral water, which removed the soaps without increasing the acidity or affecting the process yield. Afterward, the biodiesel was washed with water saturated with CO(2), a mild acid that neutralized the remaining soaps and extracted impurities. The acidity, free-glycerine, methanol and soaps concentrations were reduced to very low levels with high efficiency, and using non-corrosive acids. Independently of the initial acidity, it was possible to obtain biodiesel within EN14214 specifications. The process included the recovery of soaps by hydrolysis and esterification, making it possible to obtain the theoretical maximum amount of biodiesel. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Progress in the development of the reverse osmosis process for spacecraft wash water recovery.

    Science.gov (United States)

    Pecoraro, J. N.; Podall, H. E.; Spurlock, J. M.

    1972-01-01

    Research work on ambient- and pasteurization-temperature reverse osmosis processes for wash water recovery in a spacecraft environment is reviewed, and the advantages and drawbacks of each are noted. A key requirement in each case is to provide a membrane of appropriate stability and semipermeability. Reverse osmosis systems intended for such use must also take into account the specific limitations and requirements imposed by the small volume of water to be processed and the high water recovery desired. The incorporation of advanced high-temperature membranes into specially designed modules is discussed.

  17. Pulsed-plasma gas-discharge inactivation of microbial pathogens in chilled poultry wash water.

    Science.gov (United States)

    Rowan, N J; Espie, S; Harrower, J; Anderson, J G; Marsili, L; MacGregor, S J

    2007-12-01

    A pulsed-plasma gas-discharge (PPGD) system was developed for the novel decontamination of chilled poultry wash water. Treatment of poultry wash water in the plasma generation chamber for up to 24 s at 4 degrees C reduced Escherichia coli NCTC 9001, Campylobacter jejuni ATCC 33560, Campylobacter coli ATCC 33559, Listeria monocytogenes NCTC 9863, Salmonella enterica serovar Enteritidis ATCC 4931, and S. enterica serovar Typhimurium ATCC 14028 populations to non-detectable levels ( or = 3 log CFU/ml) in recalcitrant B. cereus NCTC 11145 endospore numbers within 30 s, the level of endospore reduction was dependent on the nature of the sparged gas used in the plasma treatments. Scanning electron microscopy revealed that significant damage occurred at the cellular level in PPGD-treated test organisms. This electrotechnology delivers energy in intense ultrashort bursts, generating products such as ozone, UV light, acoustic and shock waves, and pulsed electric fields that have multiple bactericidal properties. This technology offers an exciting complementary or alternative approach for treating raw poultry wash water and for preventing cross-contamination in processing environments.

  18. The analysis of the hot water consumption and energy performance before and after renovation in multi-apartment buildings

    Science.gov (United States)

    Tumanova, K.; Borodinecs, A.; Geikins, A.

    2017-10-01

    The article presents the results of hot water supply system analysis. Taking into account that the current consumption of hot water differs from normative values, real measured data of hot water consumption in multi-apartment buildings from year 2013 until year 2015 have been analyzed. Also, the thermal energy consumption for hot water preparation has been analyzed. Based on aggregated data and taking into account the fact that renovated systems of hot water supply in existing multi-apartment buildings have same pipelines’ diameters, it was analyzed how these systems are economically and energy efficient. For the study, residential buildings in Riga, which have different architectural and engineering solutions for hot water supply systems, were selected. The study was based on thermal energy consumption measurements, which were taken at the individual heating system’s manifolds. This study was done in order to develop database on hot water consumption in civil buildings and define difference in key performance criteria in unclassified buildings. Obtained results allows to reach European Regional Development Fund project “NEARLY ZERO ENERGY SOLUTIONS FOR UNCLASSIFIED BUILDINGS” Nr. 1.1.1.116A048 main targets.

  19. Ground-water recharge in Fortymile Wash near Yucca Mountain, Nevada, 1992--1993

    International Nuclear Information System (INIS)

    Savard, C.S.

    1994-01-01

    Quantification of the ground-water recharge from streamflow in the Fortymile Wash watershed will contribute to regional ground-water studies. Regional ground-water studies are an important component in the studies evaluating the ground-water flow system as a barrier to the potential migration of radionuclides from the potential underground high-level nuclear waste repository. Knowledge gained in understanding the ground-water recharge mechanisms and pathways in the Pah Canyon area, which is 10 km to the northeast of Yucca Mountain, may transfer to Yucca site specific studies. The current data collection network in Fortymile Canyon does not permit quantification of ground-water recharge, however a qualitative understanding of ground-water recharge was developed from these data

  20. Closed Process of Shale Oil Recovery from Circulating Washing Water by Hydrocyclones

    Directory of Open Access Journals (Sweden)

    Yuan Huang

    2016-12-01

    Full Text Available The conventional oil recovery system in the Fushun oil shale retorting plant has a low oil recovery rate. A large quantity of fresh water is used in the system, thereby consuming a considerable amount of water and energy, as well as polluting the environment. This study aims to develop a closed process of shale oil recovery from the circulating washing water for the Fushun oil shale retorting plant. The process would increase oil yield and result in clean production. In this process, oil/water hydrocyclone groups were applied to decrease the oil content in circulating water and to simultaneously increase oil yield. The oil sludge was removed by the solid/liquid hydrocyclone groups effectively, thereby proving the smooth operation of the devices and pipes. As a result, the oil recovery rate has increased by 5.3 %, which corresponds to 230 tonnes a month.

  1. Electrochemical advanced oxidation processes as decentralized water treatment technologies to remediate domestic washing machine effluents.

    Science.gov (United States)

    Dos Santos, Alexsandro Jhones; Costa, Emily Cintia Tossi de Araújo; da Silva, Djalma Ribeiro; Garcia-Segura, Sergi; Martínez-Huitle, Carlos Alberto

    2018-03-01

    Water scarcity is one of the major concerns worldwide. In order to secure this appreciated natural resource, management and development of water treatment technologies are mandatory. One feasible alternative is the consideration of water recycling/reuse at the household scale. Here, the treatment of actual washing machine effluent by electrochemical advanced oxidation processes was considered. Electrochemical oxidation and electro-Fenton technologies can be applied as decentralized small-scale water treatment devices. Therefore, efficient decolorization and total organic abatement have been followed. The results demonstrate the promising performance of solar photoelectro-Fenton process, where complete color and organic removal was attained after 240 min of treatment under optimum conditions by applying a current density of 66.6 mA cm -2 . Thus, electrochemical technologies emerge as promising water-sustainable approaches.

  2. Recycling of fresh concrete exceeding and wash water in concrete mixing plants

    Directory of Open Access Journals (Sweden)

    Férriz Papí, J. A.

    2014-03-01

    Full Text Available The exceeding concrete and washing equipment water are a matter to solve in concrete production. This paper explains several possibilities for recycling and analyses the products obtained with one recycling equipment. The objective of this work is to study the possibility to increase the percentage of recycling in new mixes. The developed study relates wash water density and fine particles content. Besides, mortar and concrete samples were tested introducing different quantities of these fine particles, substituting cement, sand or only as an addition. Consistency, compressive strength, setting time, absorption, and capillarity were tested. The results indicated an improvement of the studied properties in some percentages when substituting sand. It confirms the possibility to introduce larger quantities of wash water in new concrete mixes, with corrections in sand quantity depending on water density.Los hormigones frescos sobrantes y aguas procedentes de la limpieza de equipos son un inconveniente a resolver en las plantas de hormigón. Este artículo explica varias posibilidades de reciclado y analiza los productos obtenidos en un equipo reciclador concreto, con el objetivo de estudiar el incremento del porcentaje de reciclaje en nuevas amasadas. El estudio realizado relaciona la densidad del agua de lavado y el contenido de partículas finas. Además, ensaya muestras de mortero y hormigón realizando sustituciones de estas partículas finas por cemento, arena o simplemente como adición. Determina consistencia, resistencia a compresión, principio y fin de fraguado, absorción y capilaridad. Los resultados indicaron un incremento general de las propiedades estudiadas en algunos porcentajes de sustitución por arena. Ello confirma la posibilidad de introducir mayores cantidades de agua de lavado en nuevas amasadas de hormigón, mediante correcciones en la dosificación de arena en función de la densidad del agua.

  3. Water reuse potential in truck wash using a Rotating Biological Contactor

    Directory of Open Access Journals (Sweden)

    Eduardo Lucas Subtil

    2016-11-01

    Full Text Available This study evaluated the water reuse potential for truck washing using the effluent treated by a Rotating Biological Contactor (RBC operated in full scale. In order to evaluate the reuse potential, a mass balance was performed for the reuse system taking into account the concentration of Total Dissolved Solids as the critical contaminant. The treatment system produced an effluent with average concentration of color, turbidity, TDS and BOD5 of 45 ± 14 uC, 15 ± 6.0 NTU, 244 ± 99 mg TDS / L and 14 ± 7.3 mg O2 / L, respectively. Based on the mass balance, and considering the TDS concentration established in NBR 13.696, if the final rinse does not use clean water, the potential for effluent reuse can reach 40%. However, if clean water is used as 30% of the total rinsing volume, it would be possible to reuse 70% of the treated effluent without compromising truck washing performance. This water reuse approach would result in an operational cost reduction of R$ 2,590.75/month.

  4. Water reuse potential in truck wash using a Rotating Biological Contactor

    OpenAIRE

    Eduardo Lucas Subtil; José Carlos Mierzwa; Ivanildo Hespanhol; Raphael Rodrigues

    2016-01-01

    This study evaluated the water reuse potential for truck washing using the effluent treated by a Rotating Biological Contactor (RBC) operated in full scale. In order to evaluate the reuse potential, a mass balance was performed for the reuse system taking into account the concentration of Total Dissolved Solids as the critical contaminant. The treatment system produced an effluent with average concentration of color, turbidity, TDS and BOD5 of 45 ± 14 uC, 15 ± 6.0 NTU, 244 ± 99 mg TDS / L and...

  5. Soil washing

    International Nuclear Information System (INIS)

    Neuman, R.S.; Diel, B.N.; Halpern, Y.

    1992-01-01

    Disposal of soils or sludges contaminated with organic and inorganic compounds is a major problem for environmental remedial activities, hazardous waste generators, and the disposal industry. This paper reports that many of these wastes can be effectively treated utilizing soil washing technology. CWM has been developing soil washing technology over the past few years, with extensive work being conducted on the bench scale. These studies have demonstrated consistently high removal efficiencies (95-99%) for a wide variety of PCB and petroleum hydrocarbon contaminated waste. Recently, a comprehensive study examining the removal of both organic and inorganic contraminants from two different types of surrogate soil matrices was completed. In addition to establishing the range of contaminants that can be removed from soil, a method for surfactant/water separation was evaluated. For example, using a thermal phase separation method, approximately 90% of the surfactant could be recovered from the water

  6. Evidence on the Effectiveness of Water, Sanitation, and Hygiene (WASH Interventions on Health Outcomes in Humanitarian Crises: A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Anita Ramesh

    Full Text Available Water, sanitation, and hygiene (WASH interventions are amongst the most crucial in humanitarian crises, although the impact of the different WASH interventions on health outcomes remains unclear.To examine the quantity and quality of evidence on WASH interventions on health outcomes in humanitarian crises, as well as evaluate current evidence on their effectiveness against health outcomes in these contexts.A systematic literature review was conducted of primary and grey quantitative literature on WASH interventions measured against health outcomes in humanitarian crises occurring from 1980-2014. Populations of interest were those in resident in humanitarian settings, with a focus on acute crisis and early recovery stages of humanitarian crises in low and middle-income countries. Interventions of interest were WASH-related, while outcomes of interest were health-related. Study quality was assessed via STROBE/CONSORT criteria. Results were analyzed descriptively, and PRISMA reporting was followed.Of 3963 studies initially retrieved, only 6 published studies measured a statistically significant change in health outcome as a result of a WASH intervention. All 6 studies employed point-of-use (POU water quality interventions, with 50% using safe water storage (SWS and 35% using household water treatment (HWT. All 6 studies used self-reported diarrhea outcomes, 2 studies also reported laboratory confirmed outcomes, and 2 studies reported health treatment outcomes (e.g. clinical admissions. 1 study measured WASH intervention success in relation to both health and water quality outcomes; 1 study recorded uptake (use of soap as well as health outcomes. 2 studies were unblinded randomized-controlled trials, while 4 were uncontrolled longitudinal studies. 2 studies were graded as providing high quality evidence; 3 studies provided moderate and 1 study low quality evidence.The current evidence base on the impact of WASH interventions on health outcomes in

  7. Evidence on the Effectiveness of Water, Sanitation, and Hygiene (WASH) Interventions on Health Outcomes in Humanitarian Crises: A Systematic Review.

    Science.gov (United States)

    Ramesh, Anita; Blanchet, Karl; Ensink, Jeroen H J; Roberts, Bayard

    2015-01-01

    Water, sanitation, and hygiene (WASH) interventions are amongst the most crucial in humanitarian crises, although the impact of the different WASH interventions on health outcomes remains unclear. To examine the quantity and quality of evidence on WASH interventions on health outcomes in humanitarian crises, as well as evaluate current evidence on their effectiveness against health outcomes in these contexts. A systematic literature review was conducted of primary and grey quantitative literature on WASH interventions measured against health outcomes in humanitarian crises occurring from 1980-2014. Populations of interest were those in resident in humanitarian settings, with a focus on acute crisis and early recovery stages of humanitarian crises in low and middle-income countries. Interventions of interest were WASH-related, while outcomes of interest were health-related. Study quality was assessed via STROBE/CONSORT criteria. Results were analyzed descriptively, and PRISMA reporting was followed. Of 3963 studies initially retrieved, only 6 published studies measured a statistically significant change in health outcome as a result of a WASH intervention. All 6 studies employed point-of-use (POU) water quality interventions, with 50% using safe water storage (SWS) and 35% using household water treatment (HWT). All 6 studies used self-reported diarrhea outcomes, 2 studies also reported laboratory confirmed outcomes, and 2 studies reported health treatment outcomes (e.g. clinical admissions). 1 study measured WASH intervention success in relation to both health and water quality outcomes; 1 study recorded uptake (use of soap) as well as health outcomes. 2 studies were unblinded randomized-controlled trials, while 4 were uncontrolled longitudinal studies. 2 studies were graded as providing high quality evidence; 3 studies provided moderate and 1 study low quality evidence. The current evidence base on the impact of WASH interventions on health outcomes in humanitarian

  8. Dye Removal From Textile Waste Water Through The Adsorption By Pumice Used In Stone Washing

    Directory of Open Access Journals (Sweden)

    Körlü Aysegül Ekmekçi

    2015-09-01

    Full Text Available Because the waste production is inevitable in almost all industries, the elimination of these wastes is a requirement in terms of environmental regulations and welfare of all the creatures in the future. In this study, the use of the waste pumice stones of a denim washing mill is intended to eliminate the pollutant by a waste material and obtain economic benefits by converting it to the adsorbent. The pollutants in the effluents obtained from three different localisations of waste water treatment system of the same factory were removed through the adsorption. The experimental studies were carried out in three different steps; characterisation of adsorbent before and after adsorption; adsorption isotherm studies and biological oxygen demand (BOD, chemical oxygen demand (COD measurements. Characterisation studies showed that the waste pumice has almost the same structural properties with unused one except the existence of some organic residues coming from washing process. The results of adsorption studies conducted at the adsorbent concentrations changing from 5 to 35 g/l revealed that the decolourisation was initial dye-concentration dependent. According to the BOD and COD measurements, the supernatants obtained at the end of adsorption could be assumed as somewhat polluted and this result indicates that the organic impurities other than indigo were also removed through the adsorption.

  9. Evaluation and comparison of closed-loop wash-water system

    International Nuclear Information System (INIS)

    Whitney, P.M.; Greer, C.R.

    1991-01-01

    Effluent from vehicle and equipment cleaning is known to contain a variety of potential pollutants, the most common being hydrocarbons and suspended solids. Proper treatment and discharge of this effluent is a growing concern as environmental awareness increases. In the United States, discharge of this effluent to municipal sewage treatment systems requires a permit from local authorities, discharge to surface waters requires a federal permit and, in most cases, discharge to the ground in prohibited. Furthermore, discharge to ground and surface waters can cause soil or groundwater contamination resulting in property devaluation, adverse impact on human health, fines from regulatory agencies, expensive cleanup and negative publicity. Effluent from vehicle washing typically does not meet the minimum pollutant levels allowed by regulatory agencies for discharge to surface waters or sewage treatment plants. Because of the liability associated with discharge to ground and surface waters and the difficulty in meeting municipal sewer discharge permit requirements, closed-loop wastewater treatment is an attractive alternative to discharge. Evaluation and comparison of systems from each category constitute the basis of this paper. Factors involved in selecting a system and available water-treatment technologies are discussed. The conclusion summarizes the results of the system comparison and makes recommendations for selecting and installing closed-loop water treatment systems for vehicle and equipment cleaning

  10. The study of road surface micro-texture's effects for the pavement's decontamination by high pressure water washing

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Shimizu, Tadaaki; Hirayama, Takahiro

    2014-01-01

    In the result of “decontamination technical demonstration project” by Ministry of the Environment, it has became clear that the effect variation is larger in high pressure water washing method, compared with others in road surface decontamination technology. In this study, we have hypothesized the fact at the difference of micro-texture of the road surface, by carrying out high pressure water washing method in different kinds of road surfaces and verified the relation between washing efficiency and micro-texture road surface. Positive correlation has admitted between the washing number of times and radiation reduction rate and the trend of primary regression equation (i.e. radiation reduction rate per washing time) is indicating that decreasing tendency of radiation carried by the increasing of micro-texture of the road surface. Here, we proposed the method to estimated essential washing number of times to achieve the targeted radiation reduction rate from the relation of that trend and micro-texture of the road surface. (author)

  11. Solar renovation demonstration projects

    Energy Technology Data Exchange (ETDEWEB)

    Bruun Joergensen, O [ed.

    1998-10-01

    In the framework of the IEA SHC Programme, a Task on building renovation was initiated, `Task 20, Solar Energy in Building Renovation`. In a part of the task, Subtask C `Design of Solar Renovation Projects`, different solar renovation demonstration projects were developed. The objective of Subtask C was to demonstrate the application of advanced solar renovation concepts on real buildings. This report documents 16 different solar renovation demonstration projects including the design processes of the projects. The projects include the renovation of houses, schools, laboratories, and factories. Several solar techniques were used: building integrated solar collectors, glazed balconies, ventilated solar walls, transparent insulation, second skin facades, daylight elements and photovoltaic systems. These techniques are used in several simple as well as more complex system designs. (au)

  12. Dichlorvos (DDVP residue removal from tomato by washing with tap and ozone water, a commercial detergent solution and ultrasonic cleaner

    Directory of Open Access Journals (Sweden)

    Ali HESHMATI

    Full Text Available Abstract Dichlorvos (DDVP is one of the most consumption chlorinated organophosphate insecticide used on tomato. The knowledge about the influence of postharvest household processes on the levels of DDVP residues in vegetables is required to estimate dietary exposure. In this study, the removal of sprayed dichlorvos (DDVP on tomato by washing with tap, ozonated water (in dosages of 2, 4 and 6 mg ozone/L, a commercial detergent solution (in concentration of 1, 2 and 3% and ultrasonic cleaner (with power of 100, 200 and 300 W was investigated. DDVP residue was determined by gas chromatography with electron capture detector. Washing processes led to the significant reduction of DDVP. The gradual increase in the percentage of the removal was observed due to increment of washing time, ozone dosage, and concentration of detergent solution as well as ultrasonic power. The maximum removal percentage of DDVP after 15 min of washing with tap and ozonated water, a detergent solution and ultrasonic cleaner was 30.7, 91.9, 70.7, and 88.9%, respectively. In general, results indicated washing with tap, ozonated water, a detergent solution and ultrasonic cleaning are effective methods for removal of DDVP from tomato and reduction of its dietary exposure without influence on product quality.

  13. Gastric washing by distilled water can reduce free gastric cancer cells exfoliated into the stomach lumen.

    Science.gov (United States)

    Ohki, Atsuko; Abe, Nobutsugu; Yoshimoto, Eri; Hashimoto, Yoshikazu; Takeuchi, Hirohisa; Nagao, Gen; Masaki, Tadahiko; Mori, Toshiyuki; Ohkura, Yasuo; Sugiyama, Masanori

    2018-04-25

    Intragastric free cancer cells in patients with gastric cancer have rarely been studied. The purpose of this study was to investigate the detection rate of intragastric free cancer cells in gastric washes using two types of solutions during endoscopic examination. We further clarified risk factors affecting the presence of exfoliated free cancer cells. A total of 175 patients with gastric cancer were enrolled. Lactated Ringer's solution (N = 89) or distilled water (DW; N = 86) via endoscopic working channel was sprayed onto the tumor surface, and the resultant fluid was collected for cytological examination. We compared the cancer-cell positivity rate between the two (Ringer and DW) groups. We also tested the correlation between cancer-cell positivity and clinicopathological factors in the Ringer group to identify risk factors for the presence of exfoliated cancer cells. The cancer-cell positivity rate was significantly higher in the Ringer group than that in the DW group (58 vs 6%). Cytomorphology in the Ringer group was well maintained, but not in the DW group. The larger tumor size (≥ 20 mm) and positive lymphatic involvement were significant risk factors of exfoliated free cancer cells. Cancer cells can be highly exfoliated from the tumor surface into the gastric lumen by endoscopic irrigation in large gastric cancer with lymphatic involvement. Gastric washing by DW can lead to cytoclasis of free cancer cells; therefore, it may minimize the possibility of cancer-cell seeding in procedures carrying potential risks of tumor-cell seeding upon transluminal communication, such as endoscopic full-thickness resection and laparoscopy-endoscopy cooperative surgery.

  14. Selected hydrologic data from Fortymile Wash in the Yucca Mountain area, Nevada, water year 1992

    Energy Technology Data Exchange (ETDEWEB)

    Savard, C.S.

    1995-02-01

    Precipitation totals of 245 and 210 mm were measured at UE-29 UZN {number_sign}91 and UE-29 UZN {number_sign}92 respectively, during the 1992 water year, October 1, 1991 to September 30, 1992. Approximately ninety percent of the precipitation fell during the period December 27 to April 2. Localized streamflow was generated in the Fortymile Wash drainage basin during the February 12-15, 1992 and March 31, 1992 precipitation, and infiltrated into the streambed materials. The streamflow went across the UE-29 UZN {number_sign}91 neutron-access borehole location and within several meters of the UE-29 UZN {number_sign}92 location. Neutron logging in these boreholes showed increases in the volumetric water content of the unsaturated alluvium and indicated streamflow infiltrated to a depth of approximately 5 meters. The volumetric water content in the upper 5 meters then gradually decreased during the remaining part of the water year. Ground-water levels rose over one meter in wells UE-29 a{number_sign}1 and UE-29 a{number_sign}2, and one-half meter in neutron-access borehole LJE-29 UZN {number_sign}91 following the streamflows. Water level declines of 0.5 meter in UE-29 a{number_sign}1 and rises of 0.2 meter in UE-29 a{number_sign}2 and 0.1 meter in UE-29 UZN {number_sign}91 coincided with a June 29, 1992 earthquake at the Little Skull Mountain, located approximately 27 kilometers southeast of the wells.

  15. Selected hydrologic data from Fortymile Wash in the Yucca Mountain area, Nevada, water year 1992

    International Nuclear Information System (INIS)

    Savard, C.S.

    1995-01-01

    Precipitation totals of 245 and 210 mm were measured at UE-29 UZN number-sign 91 and UE-29 UZN number-sign 92 respectively, during the 1992 water year, October 1, 1991 to September 30, 1992. Approximately ninety percent of the precipitation fell during the period December 27 to April 2. Localized streamflow was generated in the Fortymile Wash drainage basin during the February 12-15, 1992 and March 31, 1992 precipitation, and infiltrated into the streambed materials. The streamflow went across the UE-29 UZN number-sign 91 neutron-access borehole location and within several meters of the UE-29 UZN number-sign 92 location. Neutron logging in these boreholes showed increases in the volumetric water content of the unsaturated alluvium and indicated streamflow infiltrated to a depth of approximately 5 meters. The volumetric water content in the upper 5 meters then gradually decreased during the remaining part of the water year. Ground-water levels rose over one meter in wells UE-29 a number-sign 1 and UE-29 a number-sign 2, and one-half meter in neutron-access borehole LJE-29 UZN number-sign 91 following the streamflows. Water level declines of 0.5 meter in UE-29 a number-sign 1 and rises of 0.2 meter in UE-29 a number-sign 2 and 0.1 meter in UE-29 UZN number-sign 91 coincided with a June 29, 1992 earthquake at the Little Skull Mountain, located approximately 27 kilometers southeast of the wells

  16. Performance of high-recovery recycling reverse osmosis with wash water

    Science.gov (United States)

    Herrmann, Cal C.

    1993-01-01

    Inclusion of a recycling loop for partially-desalted water from second-stage reverse-osmosis permeate has been shown useful for achieving high-recovery at moderate applied pressures. This approach has now been applied to simulated wash waters, to obtain data on retention by the membranes of solutes in a mixture comparable to anticipated spacecraft hygiene wastewaters, and to generate an estimate of the maximum concentration that can be expected without causing membrane fouling. A first experiment set provides selectivity information from a single membrane and an Igepon detergent, as a function of final concentration. A reject concentration of 3.1% Total Organic Carbon has been reached, at a pressure of 1.4 Mega Pascals, without membrane fouling. Further experiments have generated selectivity values for the recycle configuration from two washwater simulations, as a function of applied pump pressure. Reverse osmosis removal has also been tested for washwater containing detergent formulated for plant growth compatibility (containing nitrogen, phosphorous and potassium functional groups.)

  17. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system

    Directory of Open Access Journals (Sweden)

    F. G. Fermoso

    2017-06-01

    Full Text Available Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application.

  18. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system

    International Nuclear Information System (INIS)

    Fermoso, F.G.; Fernández-Rodríguez, M.J.; Jiménez-Rodríguez, A.; Serrano, A.; Borja, R.

    2017-01-01

    Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES) operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD) removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application. [es

  19. Existing Sustainable Renovation Concepts

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Vanhoutteghem, Lies; Gustavsson, Leif

    The Nordic single-family house renovation market is dominated by a craftsman based approach with individual solutions, traditional warehouses ”do-it-yourself-shops” and some actors marketing single products. To speed up the implementation of sustainable renovation of single-family houses there is......The Nordic single-family house renovation market is dominated by a craftsman based approach with individual solutions, traditional warehouses ”do-it-yourself-shops” and some actors marketing single products. To speed up the implementation of sustainable renovation of single-family houses...

  20. Changes of washing water during debittering and the brine during storage of irradiated olive fruits (Olea Europea. 1.)

    International Nuclear Information System (INIS)

    Al-Bachir, M.

    2003-01-01

    Olive fruits (Olea Europea. var. Surrany) treated with 0, 1, 2, and 3 kGy of gamma irradiation were debittered in distilled water for 8 days and stored in brine for 12 months at room temperature. Total dissolved and inorganic dissolved solids, Na, K, Ca, electric conductivity (EC) and pH values were evaluated in washing wastewater 9 daily), and in brine (after 6 and 12 months). The results showed that gamma irradiation increased the total and inorganic dissolved solids, Na and K in washing wastewater, and in brine throughout debittering and storage periods. Also, gamma irradiation had an effect on EC and pH values of washing wastewater and brine. (author)

  1. Changes of washing water during debittering and the brine during storage of irradiated olive fruits (Olea europea. L.)

    International Nuclear Information System (INIS)

    AL-Bachir, M.

    2001-01-01

    Olive fruits (Olea europea. var. Surrany) treated with 0, 1, 2 and 3 kGy of gamma irradiation were debittered in distilled water for 8 days and stored in brine for 12 months at room temperature. Total dissolved and inorganic dissolved solids, Na, K, Ca, electric conductivity (EC) and pH values were evaluated in washing wastewater (daily), and in brine (after 6 and 12 months). The results showed that gamma irradiation increased the total and inorganic dissolved solids, Na and K in washing wastewater, and in brine throughout debittering and storage periods. Also, gamma irradiation had an effect on EC and pH values of washing wastewater and brine [es

  2. Biodiesel wash-water reuse using microfiltration: toward zero-discharge strategy for cleaner and economized biodiesel production

    Directory of Open Access Journals (Sweden)

    R. Jaber

    2015-03-01

    Full Text Available A simple but economically feasible refining method to treat and re-use biodiesel wash-water was developed. In detail, microfiltration (MF through depth-filtration configuration was used in different hybrid modules. Then, the treated wash-water was mixed with clean water at different ratios, re-used for biodiesel purification and water-washing efficiency was evaluated based on methyl ester purity analysis. The findings of the present study revealed that depth-filtration-based MF combined with sand filtration/activated carbon separation and 70% dilution rate with fresh water not only achieved standard-quality biodiesel product but also led to up to 15% less water consumption after two rounds of production operations. This would be translated into a considerable reduction in the total volume of fresh water used during the operation process and would also strengthen the environmental-friendly aspects of the biodiesel production process for wastewater generation was obviously cut by the same rate as well.

  3. Increasing the effectiveness of purification of wash water discharge during placer mining. Povyshenie effekitivnosti ochistki promstokov pri razrabotke rossypei

    Energy Technology Data Exchange (ETDEWEB)

    Volkova, V M; Matveev, A A

    1981-01-01

    In the book research results are generalized for processes of water supply and purification of wash water discharges from dredge mining of placer deposits. Aspects of the geological and mineralogical structure of the solid phase of dredge waste waters and regularities in its influence on the sedimentation capacity of the suspended matter are examined. On the basis of a study of distinctive features in the hydrodynamic processes occurring in dredge sludge-settling tanks, a method is proposed for calculation of the settling tank parameters, allowing their areas of application for wash water discharge clarification to be determined reliably. Results are reported for a study of methods of intensification of the deposition of suspended clay particles in dredge waste waters, (methods) based on the use of both a series of coagulants and flocculants producible by industry and various production wastes. Aspects of the theory and practice of organizing circulating water supply for dredges are examined. The influence of wash water discharges forming during placer mining on the environment is assessed.

  4. Preventing microbial growth on pall-rings when upgrading biogas using absorption with water wash

    Energy Technology Data Exchange (ETDEWEB)

    Haakansson, Anna

    2006-07-15

    For produced biogas to be usable as vehicle fuel it has to be upgraded to a higher energy content. This is accomplished by elevation of the methane concentration through removal of carbon dioxide. Absorption with water wash is the most common upgrading method used in Sweden today. The upgrading technique is based on the fact that carbon dioxide is more soluble in water than methane. Upgrading plants that utilises this method have problems with microbial growth in the system. This growth eventually leads to a stop in operation due to the gradually drop in upgrading capacity. The aim of this thesis were to evaluate the possibility to through some kind of water treatment maintain an acceptable level of growth or altogether prevent it in order to maintain an acceptable process capacity and thereby avoid the need to clean. Through collection of literature the implementation possibilities were evaluated with regard to efficiency, economic sustainability and if there would be a release of any harmful substances. In order to prevent the microbial growth in the columns the treatment should either focus on removing microorganisms or limit the accessible nutrients. For the single pass system it is concluded that the treatment should reduce the biofilm formation and be employed in an intermittent way. Among the evaluated treatments focusing on the reduction of microorganisms the addition of peracetic acid seems to be the most promising one. For the regenerating system the treatment method could focus on either one. As for the single pass system peracetic acid could be added to reduce the amount of microorganism. To reduce the amount of organic matter an advanced oxidation process could be deployed with the advantage that it also could remove the microorganisms.

  5. Selected hydrologic data from Fortymile Wash in the Yucca Mountain area, Nevada, water years 1993--94

    Energy Technology Data Exchange (ETDEWEB)

    Savard, C.S.

    1996-09-01

    The Yucca Mountain area is being evaluated by the US Department of Energy for its suitability to store high-level nuclear waste in a mined, underground repository. Hydrologic data are being collected by the US Geological Survey throughout a 150 Km{sup 2} study area about 15- Km northwest of Las Vegas in southern Nevada for site characterization studies. Ongoing hydrologic studies are investigating atmospheric precipitation, stream-flow, movement of water through the unsaturated zone, movement of water through the saturated zone, and paleohydrology. This study at Fortymile Wash involves some components of each of these studies. Fortymile Wash is an ephemeral stream near Yucca Mountain with tributaries draining the east side of Yucca Mountain and then forming a distributary system in the Amargosa Desert. An objective of the study is to determine the amount of recharge from Fortymile Wash to the ground-water flow system that has been proposed. Understanding the ground-water flow system is important because it is a possible mechanism for radionuclide migration from the repository to the accessible environment. An adequate understanding of the ground-water flow system is necessary for an evaluation of the safety issues involved in siting the potential repository.

  6. Testing biological effects of hand-washing grey water for reuse in irrigation on an urban farm: a case study.

    Science.gov (United States)

    Khan, Mohammad Zain; Sim, Yei Lin; Lin, Yang Jian; Lai, Ka Man

    2013-01-01

    The feasibility of reusing hand-washing grey water contaminated with antibacterial hand-washing liquid for irrigation purposes in an urban farm is explored in this case study. Experiments are carried out to investigate if the quality of this grey water allows for its reuse in agriculture as per the guidelines established by the World Health Organization (WHO). However, there is no guideline to test the biological effect of grey water prior to agricultural use. It is plausible that the antibacterial property of the grey water can harm the soil microbial system and plants when applied to land, even if all other water quality parameters satisfy the WHO limit. We use algae (Chlorella vulgaris) and indigenous soil bacteria as initial plant and soil bacteria indicators, respectively, to test the potential inhibition of the water on plants and soil bacteria. Results show that the chemical oxygen demand (COD) of the grey water is 10% higher than the WHO permissible level, while all other water quality parameters are within the limits after four days of our experimental period. An inhibitory effect is observed in all of the biological tests. However, the inhibitory effect on algae and soil bacteria is not observed after the four-day period. The case study demonstrates a new approach for testing the biological effect of grey water, which can be used in conjunction with the WHO guideline, and provides data for this urban farm to set up a future water treatment system for grey-water reuse in irrigation.

  7. The renovated Almaraz is profitable

    International Nuclear Information System (INIS)

    Vehkanen, S.; Vaelisuo, M.

    2001-01-01

    The Almaraz power plant is situated in the Province of Extremadura in southwestern Spain. In the plant there are two pressurised water reactors that are delivered by Westinghouse and commissioned in the beginning of 1980's. In mid 1990's major renovations were made by Siemens. The plant is very profitable, says plant manager Araluce. The richness of the living nature in the area surrounding the power plant was emphasized in the oral and written presentations. (author)

  8. Washing of fly ash from combustion of municipal solid waste using water as leachant; Vattentvaett av flygaska fraan avfallsfoerbraenning

    Energy Technology Data Exchange (ETDEWEB)

    Steenari, Britt-Marie; Zhao, Dongmei

    2010-03-15

    Ashes from combustion of municipal solid waste contain a large amount of minerals, salts and other metal compounds that are more or less soluble in water. The metal salts are often enriched in the fly ash which leads to a classification of the ash as hazardous waste. This makes ash management complicated and costly. Many stabilisation methods for Municipal Solid Waste Incineration (MSWI) fly ash have been developed and most of them are based on a removal of chloride and sulfate in addition to a binding of metals in less soluble forms. The aim is to avoid the common situation that the ash does not comply to leaching limit values due to release of harmless salts. The aim of this project was to investigate if a simple washing with water can remove enough of the fly ash content of chloride and sulphate so that the ash can be landfilled in a simpler and less costly way than today. The project was focused on fly ashes from the MSWI units owned by Boraas Energi och Miljoe AB and Renova AB Goeteborg, i.e. a electro filter ash from grate fired boilers at Renova and a cyclone ash from a fluid bed boiler at Boraas. The results show that the main part of the chloride content of the ashes can be removed easily, but the washing with water is less effective in the removal of sulphate. A water-to-ash ratio of 1-2 l/kg removes about 100% of chloride but only 8-16% of the sulphate content. In many cases, the leachability of sulphate increases after the washing step. This is due to the rather complex sulphate chemistry with several possible reactions taking place in the ash-water system. For both the tested ashes the high level of chloride leaching is an important factor that prevents admittance on a landfill for hazardous waste without treatment.. The leaching of certain metals, such as Pb, is also high from both ashes but in the case of the Renova fly ash this is dealt with by treatment of the ash according to the Bamberg method. After a water washing with L/S 1-2 (L/kg dry ash

  9. Effect of water-washing on the co-removal of chlorine and heavy metals in air pollution control residue from MSW incineration.

    Science.gov (United States)

    Yang, Zhenzhou; Tian, Sicong; Ji, Ru; Liu, Lili; Wang, Xidong; Zhang, Zuotai

    2017-10-01

    The present study systemically investigated the effect of a water-washing process on the removal of harmful chlorides, sulfates, and heavy metals in the air pollution control (APC) residue from municipal solid wastes incineration (MSWI), for sake of a better reuse and disposal of this kind of waste. In addition, the kinetic study was conducted to reveal the releasing mechanism of relevant element in the residue. The results show that, over 70wt.% of chlorides and nearly 25wt.% of sulfates in the residue could be removed by water washing. Based on an economical consideration, the optimal operation conditions for water washing of APC residue was at liquid/solid (L/S) ratio of 3mL:1g and extracting time of 5min. As expected, the concentrations of Co, Cr, Fe, Ni, V and Cu in the washing effluent increased with time during the washing process. However, the extracting regime differs among different heavy metals. The concentrations of Ba and Mn increased firstly but declined afterwards, and concentrations of Pb and Zn gradually declined while Cd and As kept constant with the increase of extracting time. It is worth mentioning that the bubbling of CO 2 into the washing effluent is promisingly effective for a further removal of Pb, Cu and Zn. Furthermore, kinetic study of the water washing process reveals that the extracting of heavy metals during water washing follows a second-order model. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Multivariate Statistical Analysis of Water Chemistry in Evaluating the Origin of Contamination in Many Devils Wash, Shiprock, New Mexico

    International Nuclear Information System (INIS)

    2012-01-01

    This report evaluates the chemistry of seep water occurring in three desert drainages near Shiprock, New Mexico: Many Devils Wash, Salt Creek Wash, and Eagle Nest Arroyo. Through the use of geochemical plotting tools and multivariate statistical analysis techniques, analytical results of samples collected from the three drainages are compared with the groundwater chemistry at a former uranium mill in the Shiprock area (the Shiprock site), managed by the U.S. Department of Energy Office of Legacy Management. The objective of this study was to determine, based on the water chemistry of the samples, if statistically significant patterns or groupings are apparent between the sample populations and, if so, whether there are any reasonable explanations for those groupings.

  11. Multivariate Statistical Analysis of Water Chemistry in Evaluating the Origin of Contamination in Many Devils Wash, Shiprock, New Mexico

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2012-12-31

    This report evaluates the chemistry of seep water occurring in three desert drainages near Shiprock, New Mexico: Many Devils Wash, Salt Creek Wash, and Eagle Nest Arroyo. Through the use of geochemical plotting tools and multivariate statistical analysis techniques, analytical results of samples collected from the three drainages are compared with the groundwater chemistry at a former uranium mill in the Shiprock area (the Shiprock site), managed by the U.S. Department of Energy Office of Legacy Management. The objective of this study was to determine, based on the water chemistry of the samples, if statistically significant patterns or groupings are apparent between the sample populations and, if so, whether there are any reasonable explanations for those groupings.

  12. The Integrated Renovation Process

    DEFF Research Database (Denmark)

    Galiotto, Nicolas; Heiselberg, Per; Knudstrup, Mary-Ann

    2015-01-01

    the project stakeholders to overcome most informational barriers to sustainable home renovation such as lack of knowledge, lack of interest, lack of support, and lack of social and emotional understanding. The homeowners were able to perceive the new and numerous qualities they were getting in their newly......The potential for primary energy savings is greatest in the building sector. A very relevant way to save energy is to increase the rates and depths of building renovations. In order to reach such goals, building owners need to be convinced to invest in high-performance sustainable renovation...

  13. The application of membrane technology for reuse of process water and minimisation of waste water in a textile washing range

    NARCIS (Netherlands)

    van t Hul, J.P.; Racz, I.G.; Reith, T.

    1997-01-01

    Recycling of process streams and reduction of waste disposal using membrane technology in a continuous textile washing process after dyeing with reactive dyes have been investigated theoretically. A mathematical process model of a conventional open-width washing range has been extended by membrane

  14. Renovation and design of double casement windows with regard to the occurrence of water vapour condensation or mould on the interior surface of the window jamb

    Science.gov (United States)

    Kudrnacova, L.; Balik, L.

    2017-10-01

    The condensation of water vapour on the interior surface is an indicator of construction dysfunction or ignoring of the surroundings temperature and relative humidity. This paper deals with analysis of the occurrence of condensation on the jamb of double casement windows (windows with two window casements). More precisely, this is a surface in the interior where water vapour condensation or mould occur. For the renovation of existing double casement windows, there are different solutions based on window design: application of double insulating glazing on the interior window casement, application of double insulating glazing on the exterior casement, or installation of a simple window. We first describe measurement of an existing double casement window located in a mountain cottage. Second, the results and comparison of 2D thermal model of different types of double casement window construction. Also, the external insulation of the peripheral wall was included in the model.

  15. The Integrated Renovation Process

    DEFF Research Database (Denmark)

    Galiotto, Nicolas; Heiselberg, Per; Knudstrup, Mary-Ann

    they get more time for the cost optimization and the qualitative analysis of the users’ needs and behaviours. In order to reach a fossil free energy building stock within an acceptable time frame, it is primordial that researchers, politicians and the building industry work hand in hand. Indeed, in order...... to overcome the financial barriers to energy renovation and bring a new type of building experts in the building renovation sector, cost optimization tools for building renovation have been and can be developed but new legislation and politico-economic supports are still much needed. We present in this report...... a new contribution from the research and industry sides and results reached with the newly developed methodology, but without a significant contribution from the politico-economic and legislation sides . The experiences met during application of the Integrated Renovation Process are described...

  16. Renovation of social housing

    DEFF Research Database (Denmark)

    Jensen, Stina Rask; Hvejsel, Marie Frier; Kirkegaard, Poul Henning

    consumption in the building sector. This planned transformation towards a more energy-efficient building mass involves changes in the building envelope and, as such, is likely to influence the experience of the built environment dramatically, both interior and exterior. Recent research shows, however...... in the renovation of social housing. Methodologically, this hypothesis is investigated by re-reading the task of energy renovation through the lens of tectonic architectural theory. Specifically, Eduard Sekler’s etymological distinction between structure, construction, and tectonics is developed as a framework...... for addressing the spatial implications and potentials of technical initiatives in contemporary energy renovations within the continuum described by Scott. The framework is applied in two case studies of recent energy renovations of social housing dwellings. Finally, the paper discusses whether the technical...

  17. Integrated Renovation Process

    DEFF Research Database (Denmark)

    Galiotto, Nicolas; Heiselberg, Per; Knudstrup, Mary-Ann

    2016-01-01

    renovation to be overcome. The homeowners were better integrated and their preferences and immaterial values were better taken into account. To keep the decision-making process economically viable and timely, the process as known today still needs to be improved, and new tools need to be developed....... This paper presents a new scheme: the integrated renovation process. One successful case study is introduced, and recommendations for future developments needed in the field are provided....

  18. Effect of face washing with soap and water and cleaning with antiseptics on upper-lid bacteria of surgical eye patients.

    Science.gov (United States)

    Bekibele, Charles O; Kehinde, Aderemi O; Ajayi, Benedictus G K

    2010-12-01

    To determine the effect of face washing with soap and water and cleaning with povidone iodine and cetrimide/chlorhexidine gluconate (Savlon) on upper-lid bacteria. Prospective, nonrandomized clinical trial. Eighty patients attending the Eye Clinic, University College Hospital, Ibadan, Nigeria. Eighty patients assigned to 4 groups had swabs of the upper eyelid skin taken before and after face wash with soap and water, and cleansing with Savlon and 5% povidone iodine. Specimens were cultured and Gram stained. Bacterial counts were carried out using standard techniques. Face washing with soap and water increased the proportion of patients with bacterial isolates from 80.0% to 87.5%. The average colony count increased from 187.1 to 318.5 colony units per mL (p = 0.02). Application of 5% povidone iodine without face washing with soap and water reduced the proportion of patients with bacterial isolates from 82.6% (mean count 196.5) to 28.6% (mean count 34.1)(p = 0.001); in comparison, the application of 5% povidone iodine after face washing with soap and water reduced the proportion from 71.4% (mean count 133.9) to 40.0% (mean count 69.0)(p = 0.01). Application of Savlon without face washing with soap and water reduced the proportion of patients with bacterial isolates from 100% (mean count 310.9) to 41.2% (mean count 19.8)(p = 0.004) compared with the application after face washing, which reduced the proportion from 89.5% (mean count 240.3) to 41.2% (mean count 82.9)(p = 0.02). Both povidone and Savlon are effective in reducing periocular bacteria in an African setting. Prior face washing with soap and water had no added benefit in reducing bacterial colony count.

  19. The Integrated Renovation Process

    DEFF Research Database (Denmark)

    Galiotto, Nicolas

    and constructivist multiple criteria decision-making analysis method is selected for developing the work further. The method is introduced and applied to the renovation of a multi-residential historic building. Furthermore, a new scheme, the Integrated Renovation Process, is presented. Finally, the methodology...... is applied to two single-family homes. In practice, such a scheme allowed most informational barriers to sustainable home renovation to be overcome. The homeowners were better integrated and their preferences and immaterial values were better taken into account. They assimilated the multiple benefits...... to keep the decision making process economically viable and timely, the process still needs to be improved and new tools need to be developed....

  20. Potential of activated carbon to recover randomly-methylated-β-cyclodextrin solution from washing water originating from in situ soil flushing.

    Science.gov (United States)

    Sniegowski, K; Vanhecke, M; D'Huys, P-J; Braeken, L

    2014-07-01

    Despite the overall high efficacy of cyclodextrins to accelerate the treatment of soil aquifer remediation by in-situ soil flushing, the use in practice remains limited because of the high costs of cyclodextrin and high concentrations needed to significantly reduce the treatment time. The current study tested the potential of activated carbon to treat washing water originating from soil flushing in order to selectively separate hydrocarbon contaminants from washing water containing cyclodextrin and subsequently reuse the cyclodextrin solution for reinfiltration. A high recovery of the cyclodextrin from the washing water would reduce the costs and would make the technique economically feasible for soil remediation. This study aimed to investigate whether cyclodextrin can pass through the activated carbon filter without reducing the cyclodextrin concentration when the contaminated washing water is treated and whether the presence of cyclodextrin negatively affects the purification potential of activated carbon to remove the organic pollutants from the pumped soil water. Lab-scale column experiments showed that with the appropriate activated carbon 100% of cyclodextrin (randomly-methylated-β-cyclodextrin) can be recovered from the washing water and that the effect on the efficiency of activated carbon to remove the hydrocarbon contaminants remains limited. These results show that additional field tests are useful to make in-situ soil flushing with cyclodextrin both a technical and an economical interesting technique. These results might stimulate the application of cyclodextrin in soil treatment technology. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Microbiological Evaluation of Broiler Carcasses, Wash and Rinse Water from Pluck Shops (Cottage Poultry Processors in the County Nariva/Mayaro, Trinidad, Trinidad and Tobago, West Indies

    Directory of Open Access Journals (Sweden)

    Thomas, A.

    2006-01-01

    Full Text Available A study on the prevalence and levels of Campylobacter, Salmonella and E. coli on broiler chicken carcasses, wash and rinse water from pluck shops/ cottage poultry processors (CPP in county Nariva Mayaro Trinidad was done. There are 21 pluck shops/ cottage poultry processors in the county, 14 pluck shops were randomly selected for the study. Samples consisted of 28 broiler carcasses, 14 wash water samples and 14 rinse water samples. Over all the isolation rate of Campylobacter, Salmonella and E. coli from broiler carcasses wash and rinse water showed significant differences (P< 0.05 between pluck shops. Of the 56 samples examined from the 14 pluck shops sampled, 34 (60.7% were positive for Campylobacter, 34 (60.7% for Salmonella and 40 (71.4% for E. coli. The correlation between the levels of Campylobacter found on carcasses and in wash water (r2= 0.657 and rinse water (r2= 0.600 was significant (P< 0.05 among pluck shops/CPP. There was also a high correlation (P< 0.05 between wash and rinse water samples (r2= 0.950 for Campylobacter. Salmonella levels on carcasses and in wash water were positively (P< 0.05 correlated (r2= 0.947. Of the 14 pluck shops examined 6 (42.9% had Campylobacter levels that corresponded to infectious dose in humans. The infectious doses for Salmonella were isolated from 3 (21.4% pluck shops and 13 (92.9% pluck shops evaluated had E. coli present at potentially infectious levels. Three pluck shops/CPP (21.4% had infectious dose for Campylobacter, Salmonella and E. coli where as all others had infectious levels for one or two pathogens. It was concluded that these pathogens are present in pluck shops/CPP in the county, having levels considered to be potentially infectious to humans and as such there should be health concern.

  2. Factors influencing knowledge and practice of hygiene in Water, Sanitation and Hygiene (WASH) programme areas of Bangladesh Rural Advancement Committee.

    Science.gov (United States)

    Akter, Tahera; Ali, Armm Mehrab

    2014-01-01

    Improved hygiene is one of the most effective means of reducing disease occurrence. However, a complete understanding of the factors that contribute to such improvement are not clear. This study explored factors that facilitate and/or impede hygiene behavior in water, sanitation and hygiene (WASH) intervention areas using qualitative research techniques. The Bangladesh Rural Advancement Committee (BRAC) has been providing WASH intervention to 150 rural upazilas (sub-districts) since 2006. For qualitative data collection, in-depth interviews were conducted with 144 purposively selected women from six upazilas across Bangladesh. A woman in the household was considered as a case and interviewed regarding various aspects of sanitation and hygiene, using a checklist. Some practices, such as cleanliness of latrines, and availability of soap, water, slippers in their designated place were physically verified. The respondents' hygiene behavior was mainly facilitated by improved knowledge and awareness of health and environment-related issues. Latrine ownership increased through financial assistance, resulting in improved privacy, social prestige, and a heightened sense of responsibility towards maintaining a healthy life. However, lack of interest in attending cluster meetings, traditional knowledge, poverty, and lack of will were some of the factors impeding knowledge and hygiene practice. In addition, attitude played a definitive role, with some respondents not practicing hygiene in spite of having the financial ability to do so. They expected full financial support for creating sanitation and hygiene facilities in their household despite BRAC's policy of providing such support only to the 'ultra-poor'. The identified impeding factors often act as barriers to transformation of hygiene-related knowledge into practice and practice into habit. More motivational cluster meetings with large-scale participation and periodic home visits by the programme organizers are

  3. Methodology for modeling the disinfection efficiency of fresh-cut leafy vegetables wash water applied on peracetic acid combined with lactic acid.

    Science.gov (United States)

    Van Haute, S; López-Gálvez, F; Gómez-López, V M; Eriksson, Markus; Devlieghere, F; Allende, Ana; Sampers, I

    2015-09-02

    A methodology to i) assess the feasibility of water disinfection in fresh-cut leafy greens wash water and ii) to compare the disinfectant efficiency of water disinfectants was defined and applied for a combination of peracetic acid (PAA) and lactic acid (LA) and comparison with free chlorine was made. Standardized process water, a watery suspension of iceberg lettuce, was used for the experiments. First, the combination of PAA+LA was evaluated for water recycling. In this case disinfectant was added to standardized process water inoculated with Escherichia coli (E. coli) O157 (6logCFU/mL). Regression models were constructed based on the batch inactivation data and validated in industrial process water obtained from fresh-cut leafy green processing plants. The UV254(F) was the best indicator for PAA decay and as such for the E. coli O157 inactivation with PAA+LA. The disinfection efficiency of PAA+LA increased with decreasing pH. Furthermore, PAA+LA efficacy was assessed as a process water disinfectant to be used within the washing tank, using a dynamic washing process with continuous influx of E. coli O157 and organic matter in the washing tank. The process water contamination in the dynamic process was adequately estimated by the developed model that assumed that knowledge of the disinfectant residual was sufficient to estimate the microbial contamination, regardless the physicochemical load. Based on the obtained results, PAA+LA seems to be better suited than chlorine for disinfecting process wash water with a high organic load but a higher disinfectant residual is necessary due to the slower E. coli O157 inactivation kinetics when compared to chlorine. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Determination of Arsenic in Sinus Wash and Tap Water by Inductively Coupled Plasma-Mass Spectrometry

    Science.gov (United States)

    Donnell, Anna M.; Nahan, Keaton; Holloway, Dawone; Vonderheide, Anne P.

    2016-01-01

    Arsenic is a toxic element to which humans are primarily exposed through food and water; it occurs as a result of human activities and naturally from the earth's crust. An experiment was developed for a senior level analytical laboratory utilizing an Inductively Coupled Plasma-Mass Spectrometer (ICP-MS) for the analysis of arsenic in household…

  5. Sorbent materials for rapid remediation of wash water during radiological event relief

    Energy Technology Data Exchange (ETDEWEB)

    Jolin, William C.; Kaminski, Michael

    2016-11-01

    Procedures for removing harmful radiation from interior and exterior surfaces of homes and businesses after a nuclear or radiological disaster may generate large volumes of radiologically contaminated waste water. Rather than releasing this waste water to potentially contaminate surrounding areas, it is preferable to treat it onsite. Retention barrels are a viable option because of their simplicity in preparation and availability of possible sorbent materials. This study investigated the use of aluminosilicate clay minerals as sorbent materials to retain 137Cs, 85Sr, and 152Eu. Vermiculite strongly retained 137Cs, though other radionuclides displayed diminished affinity for the surface. Montmorillonite exhibited increased affinity to sorb 85Sr and 152Eu in the presence of higher concentrations of 137Cs. To simulate flow within retention barrels, vermiculite was mixed with sand and used in small-scale column experiments. The GoldSim contaminate fate module was used to model breakthrough and assess the feasibility of using clay minerals as sorbent materials in retention barrels. The modeled radionuclide breakthrough profiles suggest that vermiculite-sand and montmorillonite-sand filled barrels could be used for treatment of contaminated water generated from field operations.

  6. Comparison of adhesive properties of water- and phosphate-buffer-washed cottonseed meals with cottonseed protein isolate on maple and poplar veneers

    Science.gov (United States)

    Water- and phosphate buffer (35 mM Na2HPO4/NaH2PO4, pH 7.5)-washed cottonseed meals (abbreviated as WCM and BCM, respectively) could be low-cost and environmentally friendly protein-based adhesives as their preparation does not involve corrosive alkali and acid solutions that are needed for cottonse...

  7. The Effect of Water Pressure and Chlorine Concentration on Microbiological Characteristics of Spray Washed Broiler Carcasses

    Directory of Open Access Journals (Sweden)

    Pissol AD

    2013-08-01

    Full Text Available The objective of this study was to evaluate the efficiency of water pressure and concentration of dichloromethane after the evisceration system under the fecal decontamination of chicken carcasse  surfaces with and without apparent contamination. From a total of  322 carcasses, 50% were intentionally added chicken droppings in an area of more  than 2 cm2 and the rest of carcasses were kept without fecal inoculation. Escherichia coli and Enterobacteriaceae counting was carried out in samples immediately after the inoculation (initial counting and after different treatments. Treatments consisted of water with different pressures (1.5,  3.5 and  5.5 Kgf/cm2, and the addition of a echnological adjuvant (dichloride at the concentrations of 0, 5 and 10 ppm. The results were validated using  40 chicken carcasses for each treatment by means of a  22  factorial statistical design. The results showed no significant differences (P

  8. Effect of water quality, sanitation, hand washing, and nutritional interventions on child development in rural Bangladesh (WASH Benefits Bangladesh): a cluster-randomised controlled trial.

    Science.gov (United States)

    Tofail, Fahmida; Fernald, Lia Ch; Das, Kishor K; Rahman, Mahbubur; Ahmed, Tahmeed; Jannat, Kaniz K; Unicomb, Leanne; Arnold, Benjamin F; Ashraf, Sania; Winch, Peter J; Kariger, Patricia; Stewart, Christine P; Colford, John M; Luby, Stephen P

    2018-04-01

    Poor nutrition and hygiene make children vulnerable to delays in growth and development. We aimed to assess the effects of water quality, sanitation, handwashing, and nutritional interventions individually or in combination on the cognitive, motor, and language development of children in rural Bangladesh. In this cluster-randomised controlled trial, we enrolled pregnant women in their first or second trimester from rural villages of Gazipur, Kishoreganj, Mymensingh, and Tangail districts of central Bangladesh, with an average of eight women per cluster. Groups of eight geographically adjacent clusters were block-randomised, using a random number generator, into six intervention groups (all of which received weekly visits from a community health promoter for the first 6 months and every 2 weeks for the next 18 months) and a double-sized control group (no intervention or health promoter visit). The six intervention groups were: chlorinated drinking water; improved sanitation; handwashing with soap; combined water, sanitation, and handwashing; improved nutrition through counselling and provision of lipid-based nutrient supplements; and combined water, sanitation, handwashing, and nutrition. Here, we report on the prespecified secondary child development outcomes: gross motor milestone achievement assessed with the WHO module at age 1 year, and communication, gross motor, personal social, and combined scores measured by the Extended Ages and Stages Questionnaire (EASQ) at age 2 years. Masking of participants was not possible. Analyses were by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01590095. Between May 31, 2012, and July 7, 2013, 5551 pregnant women residing in 720 clusters were enrolled. Index children of 928 (17%) enrolled women were lost to follow-up in year 1 and an additional 201 (3%) in year 2. 4757 children were assessed at 1 year and 4403 at 2 years. At year 1, compared with the control group, the combined water

  9. Overheating assessment of energy renovations

    DEFF Research Database (Denmark)

    Psomas, Theofanis Ch.; Heiselberg, Per Kvols; Duer, Karsten

    2016-01-01

    In many post-occupancy studies of renovated houses elevated temperatures have been documented. This article presents in which situations overheating need to be addressed and which renovation measures are causing this need. The analysis contains representative houses from central and north Europe...

  10. Improvement of Hydraulic and Water Quality Renovation Functions by Intermittent Aeration of Soil Treatment Areas in Onsite Wastewater Treatment Systems

    Directory of Open Access Journals (Sweden)

    David V. Kalen

    2010-12-01

    Full Text Available We tested intermittent aeration of the soil treatment area (STA of onsite wastewater treatment systems (OWTS for its ability to restore and maintain STA hydraulic flow and improve the water quality functions of conventional OWTS. Evaluation was conducted on hydraulically-failed conventional OWTS at three state-owned medical group homes in Washington County, RI, USA. Testing was conducted in two phases, with Phase I (before intermittent soil aeration (ISA comprising the first 6 months of the study, and Phase II (during ISA the remaining 7 months. Intermittent soil aeration restored STA hydraulic function in all three systems despite a marked reduction in the STA total infiltrative surface. Soil pore water was collected from 30 and 90 cm below the STA during both phases and analyzed for standard wastewater parameters. Although the STA infiltrative surface was reduced—and the contaminant load per unit of area increased—after installation of the ISA system, no differences were observed between phases in concentration of total N, NO3, total P, or dissolved organic carbon (DOC. Apparent removal rates—which do not account for dilution or differences in infiltrative area—for total N, total P, and DOC remained the same or improved during Phase II relative to the pre-operation phase. Furthermore, intermittent soil aeration enhanced actual removal rates —which do account for dilution and differences in infiltrative area. The effects of ISA on actual removal of contaminants from STE increased with increasing hydraulic load—a counterintuitive phenomenon, but one that has been previously observed in laboratory studies. The results of our study suggest that intermittent soil aeration can restore and maintain hydraulic flow in the STA and enhance carbon and nutrient removal in conventional OWTS.

  11. Full-scale photobioreactor for biotreatment of olive washing water: Structure and diversity of the microalgae-bacteria consortium.

    Science.gov (United States)

    Maza-Márquez, P; González-Martínez, A; Rodelas, B; González-López, J

    2017-08-01

    The performance of a full-scale photobioreactor (PBR) for the treatment of olive washing water (OWW) was evaluated under different HRTs (5-2days). The system was able to treat up to 3926L OWWday -1 , and consisted of an activated-carbon pretreatment column and a tubular PBR unit (80 tubes, 98.17L volume, 2-m height, 0.25m diameter). PBR was an effective and environmentally friendly method for the removal of phenols, COD, BOD 5 , turbidity and color from OWW (average efficiencies 94.84±0.55%, 85.86±1.24%, 99.12±0.17%, 95.86±0.98% and 87.24±0.91%, respectively). The diversity of total bacteria and microalgae in the PBR was analyzed using Illumina-sequencing, evaluating the efficiency of two DNA extraction methods. A stable microalgae-bacteria consortium was developed throughout the whole experimentation period, regardless of changes in HRT, temperature or solar radiation. MDS analyses revealed that the interplay between green algae (Sphaeropleales), cyanobacteria (Hapalosiphon) and Proteobacteria (Rhodopseudomonas, Azotobacter) played important roles in OWW bioremediation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. High concentrations of polycyclic aromatic hydrocarbons found in water and sediments of car wash and Kisat areas of Winam Gulf, Lake Victoria-Kenya.

    Science.gov (United States)

    Kwach, B O; Lalah, J O

    2009-11-01

    Mean concentrations of selected USEPA priority polycyclic aromatic hydrocarbons (PAHs) in surface sediments and water samples from Car Wash and Kisat areas of Winam Gulf, Lake Victoria in Kenya have been determined using GC-FID and GC-MS. Sampling was done during the rainy season in April 2006. The PAH concentrations in sediment and water ranged from 0.04 to 31.95 microg/g dry weight and 3.32 to 55.8 microg/L, respectively, depending upon the sampling location. The total concentration levels of PAHs in both the sediment and water phase in this study were found to be much higher compared with those reported from other regions worldwide, revealing significant PAH pollution of Car Wash and Kisat areas of Kisumu city bay as a consequent of anthropogenic activities as described in the text. The GC-detected PAHs were confirmed by GC-MS.

  13. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Anthony Cuffe; Thomas Oren

    2005-01-01

    The Machine Control Center (MCC) at Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) was constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on work-flow processes and ergonomic attributes. The renovation was performed in two phases during the summer of 2004, with one phase occurring during machine operations and the latter, more extensive phase, occurring during our semi-annual shutdown period. The new facility takes advantage of advances in display technology, analog and video signal management, server technology, ergonomic workspace design, lighting engineering, acoustic ceilings and raised flooring solutions to provide a marked improvement in the overall environment of machine operations

  14. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Thomas Oren

    2005-01-01

    The Machine Control Center (MCC) at Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) was initially constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facility's 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve workflow processes and ergonomic attributes. This effort also sets the foundation for the redevelopment of the accelerator's control system to deliver high reliability performance with improvements in beam specifications management and information flow. The complete renovation was performed over a three-week maintenance period with no interruption to beam operations. We present the results of this effort

  15. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Thomas Oren

    2005-01-01

    The Machine Control Center at Jefferson Lab's Continuous Electron Beam Accelerator Facility was initially constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on workflow processes and ergonomic attributes. This effort also sets the foundation for the redevelopment of the accelerator's control system to deliver high reliability performance with improvements in beam specifications management and information flow. The complete renovation was performed over a three-week period with no interruption to beam operations. We present the results of this effort

  16. Single treatment with ethanol hand rub is ineffective against human rhinovirus--hand washing with soap and water removes the virus efficiently.

    Science.gov (United States)

    Savolainen-Kopra, Carita; Korpela, Terttu; Simonen-Tikka, Marja-Leena; Amiryousefi, Ali; Ziegler, Thedi; Roivainen, Merja; Hovi, Tapani

    2012-03-01

    Ethanol-containing hand rubs are used frequently as a substitute for hand washing with water and soap. However, not all viruses are inactivated by a short term rubbing with alcohol. The capacity of a single round of instructed and controlled hand cleaning with water and soap or ethanol-containing hand rub, respectively, was tested for removal of human rhinovirus administered onto the skin of healthy volunteers on the back of the hands. Hand washing with soap and water appeared to be much more efficient for removing rhinoviruses from skin than rubbing hands with an ethanol-containing disinfectant. After washing with soap and water the virus was detected in 3/9 (33.3%) test persons from the left hand and 1/9 (11.1%) cases from the right hand, whereas the virus was detected invariably by real-time RT-PCR from both hands after cleaning with alcohol hand rub (P-value soap can clean efficiently hands contaminated with the virus responsible for an extensive share of common cold episodes. Copyright © 2012 Wiley Periodicals, Inc.

  17. Knowledge and practices regarding water, sanitation and hygiene (WASH) among mothers of under-fives in Mawabeni, Umzingwane District of Zimbabwe

    Science.gov (United States)

    Demberere, Tendai; Chidziya, Tayedza; Ncozana, Tatenda; Manyeruke, Norman

    2016-04-01

    The research study sought to assess knowledge and practices of mothers of under-fives regarding WASH in Mawabeni communal area in Zimbabwe. Focus group discussions, interviews, questionnaires and observation checklists were used to collect data. Data was analysed by developing specific themes related to the objectives and then frequencies were computed in Microsoft Excel. The mean score on WASH knowledge for the mothers of under-fives according to the Knowledge Index was 1. Knowledge regarding safety of water from different sources was generally poor with 70% of the mothers regarding water from surface sources to be safe to drink without treatment. Use of wide mouthed containers without lids was also common in the study area. However, no relationship was established between the type of water container used and the socio-demographic characteristics of the respondents. Knowledge regarding the importance of ablutions was generally good as highlighted by 78% of the mothers who regarded latrines as being important in prevention and control of diseases as well as for hygiene purposes. However, latrine ownership was noted to be related to the income level of the household (p sanitation practices on WASH among mothers of under-fives in Mawabeni were both poor and this could be a contributory factor to the high incidence of diarrheal diseases for under-fives in the area.

  18. Process for washing electromagnetic filters

    International Nuclear Information System (INIS)

    Guittet, Maurice; Treille, Pierre.

    1980-01-01

    This process concerns the washing of an electro-magnetic filter used, inter alia, for filtering the drain-off waters of nuclear power station steam generators, by means of a washing water used in closed circuit and freed, after each cleaning, of the solids in suspension it contains, by settlement of these solids. This invention enables the volume of water to be evaporated to be divided by 50, thereby providing a solid assurance of better safety, apart from a very significant saving [fr

  19. Solvent wash solution

    International Nuclear Information System (INIS)

    Neace, J.C.

    1986-01-01

    This patent describes a process for removing diluent degradation products from a solvent extraction solution comprising an admixture of an organic extractant for uranium and plutonium and a non-polar organic liquid diluent, which has been used to recover uranium and plutonium from spent nuclear fuel. Comprising combining a wash solution consisting of: (a) water; and (b) a positive amount up to about, an including, 50 volume percent of at least one highly-polar water-miscible organic solvent, based on the total volume of the water and the highly-polar organic solvent, with the solvent extraction solution after uranium and plutonium values have been stripped from the solvent extraction solution, the diluent degradation products dissolving in the highly-polar organic solvent and the extractant and diluent of the extraction solution not dissolving in the highly-polar organic solvent, and separating the highly-polar organic solvent and the extraction solution to obtain a purified extraction solution

  20. Renovation of the CERN outdoor lighting

    CERN Multimedia

    GS Department

    2010-01-01

    Due to the renovation of the CERN outdoor lighting, traffic will be limited to one way along “Route Gregory” from the E entrance (France) up to “Route Fermi” just before the water tower between 12th and 23rd July 2010. Disruption can also be expected in the car parks “Les Erables” and “Les Tilleuls” close to building 30 and also the car park in front of building 377, between 19th and 30th July 2010. Thanks for your understanding. SEM Group

  1. Extensive renovation the pathology of heritage building

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2015-01-01

    The pathology of heritage buildings is often related to renovation initiatives typically initiated by implementing energy savings measures.......The pathology of heritage buildings is often related to renovation initiatives typically initiated by implementing energy savings measures....

  2. Extensive renovation the pathology of heritage buildings

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2015-01-01

    The pathology of heritage buildings is often related to renovation initiatives typically initiated by implementing energy savings measures.......The pathology of heritage buildings is often related to renovation initiatives typically initiated by implementing energy savings measures....

  3. The Optimal Time of Renovating a Mall

    OpenAIRE

    K.C. Wong; George Norman

    1994-01-01

    This paper presents a maximization model determining the optimal time at which a mall should be renovated. The analysis is constructed on the assumption of a decreasing rental income over time as a mall ages. It is then shown that the optimal renovation period achieves a balance between the marginal cost and benefits of delaying renovation. We show how this balance is affected by changes in the discount rate, net rental incomes, and renovation costs. Numerical simulations are used to demonstr...

  4. Irreversible Wash Aid Additive for Cesium Mitigation: WARRP Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Michael [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-01-01

    This activity demonstrated, on a practical scale, the primary unit operations for building a containment structure for radioactive wash waters, washing down a hypothetically radioactively contaminated vehicle, collecting the hypothetically radioactive slurry waste water, filtering the hypothetically radioactive wash waters, disassembling the containment, and transporting the materials for final disposition.

  5. Irreversible Wash Aid Additive for Cesium Mitigation: Phase II. Selection and/or Modification of COTS Field Portable Waste Water Systems

    International Nuclear Information System (INIS)

    Kaminski, Michael; Mertz, Carol; Kivenas, Nadia; Magnuson, Matthew

    2015-01-01

    After an accidental or malicious release of radioactivity, large urban areas may be contaminated, compromising response efforts by first responders and law enforcement officials. In addition, some public services (e.g., drinking water and wastewater treatment, electrical power distribution, etc.) may be disrupted. In such an event, it may be important to deploy mitigation efforts in certain areas to restore response activities and public services (Fig. S-1). This report explores the state-of-the-art approach for a system to rapidly return critical infrastructure components to service following a cesium-137 (Cs-137) radiological dispersal device (RDD) release while avoiding the spread of Cs-137 beyond its original deposition area and minimizing the amount of Cs-137-contaminated wastewater. Specifically, we describe a wash system consisting of chemical additives added to fire hydrant water and irreversible solid sequestering agents added as the water is collected and treated for recycle in situ. The wash system is intended to be a rapidly deployable, cost-effective means of mitigating an urban setting for the purpose of restoring critical infrastructure and operational activities after a radiological release.

  6. Application of solar energy to the supply of industrial process hot water. Aerotherm final report, 77-235. [Can washing in Campbell Soup plant

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-01-01

    The objectives of the Solar Industrial Process Hot Water Program are to design, test, and evaluate the application of solar energy to the generation and supply of industrial process hot water, and to provide an assessment of the economic and resource benefits to be gained. Other objectives are to stimulate and give impetus to the use of solar energy for supplying significant amounts of industrial process heat requirements. The plant selected for the design of a solar industrial process hot water system was the Campbell Soup facility in Sacramento, California. The total hot water demand for this plant varies between 500 and 800 gpm during regular production shifts, and hits a peak of over 1,000 gpm for approximately one hour during the cleanup shift. Most of the hot water is heated in the boiler room by a combination of waste heat recovery and low pressure (5 psi) steam-water heat exchangers. The hot water emerges from the boiler room at a temperature between 160/sup 0/F and 180/sup 0/F and is transported to the various process areas. Booster heaters in the process areas then use low pressure (5 psi) or medium pressure (20 psi) steam to raise the temperature of the water to the level required for each process. Hot water is used in several processes at the Campbell Soup plant, but the can washing process was selected to demonstrate the feasibility of a solar hot water system. A detailed design and economic analysis of the system is given. (WHK)

  7. Renovation of the outside lighting - Bldg. 112 zone

    CERN Multimedia

    GS Department

    2010-01-01

    Due to the renovation of the outside lighting, the traffic will be disrupted along “Route Feynman”. From the water tower (Bldg. 227) to Restaurant Nr. 2 (Bldg. 504) between 18 and 30 August. We recommend great caution. Thank you for your understanding. SEM Group

  8. Late Washing efficiency

    International Nuclear Information System (INIS)

    Morrissey, M.F.

    1992-01-01

    Interim Waste Technology has demonstrated the Late Washing concept on the Experimental Laboratory Filter (ELF) at TNX. In two tests, washing reduced the [NO 2 - ] from 0.08 M to approximately 0.01 M on slurries with 2 year equivalent radiation exposures and 9.5 wt. % solids. For both washes, the [NO 2 - ] decreased at rates near theoretical for a constant volume stirred vessel, indicating approximately l00% washing efficiency. Permeate flux was greater than 0.05 gpm/ft 2 for both washes at a transmembrane pressure of 50 psi and flow velocity of 9 ft/sec

  9. Tomato type and post-treatment water rinse affect efficacy of acid washes against Salmonella enterica inoculated on stem scars of tomatoes and product quality.

    Science.gov (United States)

    Fan, Xuetong; Gurtler, Joshua B; Sokorai, Kimberly J B

    2018-09-02

    A study was conducted to evaluate the effects of post-treatment rinsing with water on the inactivation efficacy of acid treatments against Salmonella inoculated onto stem scar areas of two types of tomatoes. In addition, impact on fruit quality was investigated during 21 days post-treatment storage at 10 °C. A four-strain cocktail of Salmonella enterica (S. Montevideo, S. Newport, S. Saintpaul, and S. Typhimurium) was inoculated onto stem scar areas of grape and large round tomatoes. The inoculated fruits were then treated for 2 min with the following solutions: water, 2% lactic acid +2% acetic acid +2% levulinic acid, 1.7% lactic acid +1.7% acetic acid +1.7% levulinic acid, and 3% lactic acid +3% acetic acid. After treatments, half of the fruits were rinsed with water while another half were not rinsed. Non-inoculated grape tomatoes for quality analysis were treated with the same solutions with and without subsequent water rinse. Results demonstrated that the acid combinations reduced populations of Salmonella enterica on the stem scar area of grape tomatoes by 1.52-1.90 log CFU/fruit, compared with the non-treated control while water wash and rinse removed the bacterium by only 0.23-0.30 log CFU/fruit. On the stem scar of large round tomatoes, the same acid treatments achieved 3.54 log CFU/fruit reduction of the pathogen. The varying response to the acid washes between grape and large round tomatoes seems to be related to the differences in surface characteristics of stem scar areas observed with SEM. Rinsing with water after acid combination treatments did not significantly affect the efficacy of the treatments in either grape or large round tomatoes. Acidic off-odor was detected on fruits treated with acid combination without water rinse 1 day after treatment while water rinse eliminated the off-odor. The acid treatments with and without water rinse did not consistently affect appearance, color, firmness, or lycopene or ascorbic acid contents of

  10. WASH-1400: quantifying the uncertainties

    International Nuclear Information System (INIS)

    Erdmann, R.C.; Leverenz, F.L. Jr.; Lellouche, G.S.

    1981-01-01

    The purpose of this paper is to focus on the limitations of the WASH-1400 analysis in estimating the risk from light water reactors (LWRs). This assessment attempts to modify the quantification of the uncertainty in and estimate of risk as presented by the RSS (reactor safety study). 8 refs

  11. Effects of Particle Size on the Morphology and Water- and Thermo-Resistance of Washed Cottonseed Meal-Based Wood Adhesives

    Directory of Open Access Journals (Sweden)

    Zhongqi He

    2017-12-01

    Full Text Available Water washing of cottonseed meal is more cost-efficient and environmentally friendly than protein isolation by means of alkaline extraction and acidic precipitation. Thus, water-washed cottonseed meal (WCSM is more promising as biobased wood adhesives. In this work, we examined the effects of the particle size on the morphology and adhesive performance of WCSM. Pilot-scale produced and dried WCSM was treated by three grinding methods: (1 ground by a hammer mill and passed through a 0.5-mm screen, (2 further ground by a cyclone mill and passed through a 0.5-mm screen, or (3 further ground by a ball mill and passed through a 0.18-mm screen. Micro-morphological examination revealed two types of particles. The filament-like particles were mainly fibrous materials from residual linters. Chunk-like particles were more like aggregates or accumulations of small particles, with proteins as the major component. Further grinding of the 0.5-mm Hammer product with the Cyclone and Ball mill led to more fine (smaller particles in the WCSM products. The impact of further grinding on the dry and soaked adhesive strengths was minimal. However, the decrease of the hot and wet strengths of WCSM products by the additional grinding was significant (p ≤ 0.05. Data presented in this work is useful in developing the industrial standards of WCSM products used in wood bonding.

  12. Assessing the Health Impact of the following Measures in Schools in Maradi (Niger: Construction of Latrines, Clean Water Supply, Establishment of Hand Washing Stations, and Health Education

    Directory of Open Access Journals (Sweden)

    Halima Boubacar Maïnassara

    2014-01-01

    Full Text Available Objective. To assess the effect on health of the following measures in schools in Maradi (Niger: clean water supply, construction of latrines, establishment of hand washing stations, and health education. Methodology. It was a “before and after” intervention study on a sample of school children aged 7 to 12 years in the Maradi region. The interventions included building of latrines, supplying clean water, setting up hand washing stations, and teaching health education lessons. An individual questionnaire, analysis of stool samples, and a group questionnaire were administered to children and teachers, respectively. The threshold for significance was set at P<0.05. Results. A statistically significant reduction in cases of diarrhoea and abdominal pains was noted after the project. Overall, carriage of at least one parasite increased from 7.5% before the project to 10.2% after it (P=0.04. In the programme group schools, there was a statistically significant increase in the prevalence of Hymenolepis nana, from 0 to 1.9 (P=0.02. Pinworm prevalence remained stable in this group but increased significantly in the control group. Conclusions. Putting health infrastructure in place in schools obviously had an impact on hygiene-related habits in the beneficiary schools and communities.

  13. Washing water treatment process for UF_6 cylinder by adjusting evaporation technology in a low temperature and low pressure

    International Nuclear Information System (INIS)

    Kim, Ki-tae; Ju, Young-jong; Cho, Nam-chan; Kim, Yun-kwan; Jin, Chang-suk

    2016-01-01

    The liquid waste is treated in this procedure; 1) Add NaOH to the liquid waste and filter the mixture with a screen. 2) Screened residue is dried and then stored in a uranium storage. 3) liquid part is moved to a storage tank and radioactivity is measured in the liquid. 5) If the concentration of radioactivity is lower than corresponding regulation limit, the liquid moved to a reaction tank and evaporated with additional low concentration HF in 105℃. 6) Radioactivity of distillate is measured and the value is lower than regulation, it is treated with a thermal decomposition process and discharged to the atmosphere in gas state. 7) Solid waste produced in the evaporation step is managed as solid nuclear waste. The treatment procedure mentioned above has disadvantageous points, producing large amount of solid waste as well as, high energy and chemical consumption. In this study, liquid waste from a real scaled cylinder wash process is applied to evaporation system to confirm feasibility of the application of evaporation and, to reduce waste production and energy consumption. Liquid radioactive wastewater from a real scaled UF6 cylinder wash process was applied to evaporation treatment system. Radioactive concentration in gross alpha was removed 99.9% in the evaporation system. And the concentration in distillate was lower than the discharge regulation. Removal of U-235 was 99.9% in the process. And 15 other kinds of radionuclides in the raw wastewater were removed completely. Secondary waste production of the evaporation system is 15g/L

  14. Alternative Antimicrobial Commercial Egg Washing Procedures.

    Science.gov (United States)

    Hudson, Lauren K; Harrison, Mark A; Berrang, Mark E; Jones, Deana R

    2016-07-01

    Commercial table eggs are washed prior to packaging. Standard wash procedures use an alkaline pH and warm water. If a cool water method could be developed that would still provide a microbiologically safe egg, the industry may save energy costs associated with water heating. Four wash procedures were evaluated for Salmonella reduction: pH 11 at 48.9°C (industry standard), pH 11 at ambient temperature (∼20°C), pH 6 at 48.9°C, and pH 6 at ambient temperature. Alkaline washes contained potassium hydroxide-based detergent, while pH 6 washes contained approximately 200 ppm of chlorine and a proprietary chlorine stabilizer (T-128). When eggs were inoculated by immersion in a cell suspension of Salmonella Enteritidis and Salmonella Typhimurium, all treatments resulted in a slight and similar reduction of Salmonella numbers (approximately 0.77 log CFU/ml of shell emulsion reduction). When eggs were inoculated by droplet on the shell surface, Salmonella counts were reduced by approximately 5 log CFU when washed with chlorine plus the chlorine stabilizer at both temperatures and with the alkaline wash at the high temperature. The reductions in Salmonella by these treatments were not significantly (P > 0.05) different from each other but were significantly (P pH 11 warm water wash and may be a viable option to reduce cost, increase shelf life, and slow pathogen growth in and on shell eggs.

  15. Sewerage systems: Overflow problems and renovation methods

    Energy Technology Data Exchange (ETDEWEB)

    Tanttu, Unto [Plancenter Ltd. (Finland)

    1987-12-15

    Total investments in Finland (1984) spent on sewer systems were roughly FIM 590 million. A big share, about 14 % of this sum (FIM 82 million), was spent on rehabilitation of networks. But is this still enough? According to some evaluations the respective amount should be about FIM 500 million for rehabilitation only. So the question, how to keep the performance of sewer networks satisfactory in the future, is really important. The overflow problem is one of the most serious problems caused by old and improperly working sewer systems. Anyhow, several other aspects of a poor condition of sewers are to be seen: - excess hydraulic loading of treatment plants, - normal maintenance and operation (flushing, opening of clogs) increases, and is more expensive, - unexpected renovation works and interruptions in operation cause e.g. troubles in traffic, odour problems in the environment, hygienic hazards etc., - the performance of other underground networks (water pipes, district heating pipes etc.) may be threatened by earth crushings due to old sewers. In this paper a short description of these items is presented as well as a description of the sewer renovation methods used recently in Finland.

  16. Cluster-randomised controlled trials of individual and combined water, sanitation, hygiene and nutritional interventions in rural Bangladesh and Kenya: the WASH Benefits study design and rationale

    Science.gov (United States)

    Arnold, Benjamin F; Null, Clair; Luby, Stephen P; Unicomb, Leanne; Stewart, Christine P; Dewey, Kathryn G; Ahmed, Tahmeed; Ashraf, Sania; Christensen, Garret; Clasen, Thomas; Dentz, Holly N; Fernald, Lia C H; Haque, Rashidul; Hubbard, Alan E; Kariger, Patricia; Leontsini, Elli; Lin, Audrie; Njenga, Sammy M; Pickering, Amy J; Ram, Pavani K; Tofail, Fahmida; Winch, Peter J; Colford, John M

    2013-01-01

    Introduction Enteric infections are common during the first years of life in low-income countries and contribute to growth faltering with long-term impairment of health and development. Water quality, sanitation, handwashing and nutritional interventions can independently reduce enteric infections and growth faltering. There is little evidence that directly compares the effects of these individual and combined interventions on diarrhoea and growth when delivered to infants and young children. The objective of the WASH Benefits study is to help fill this knowledge gap. Methods and analysis WASH Benefits includes two cluster-randomised trials to assess improvements in water quality, sanitation, handwashing and child nutrition—alone and in combination—to rural households with pregnant women in Kenya and Bangladesh. Geographically matched clusters (groups of household compounds in Bangladesh and villages in Kenya) will be randomised to one of six intervention arms or control. Intervention arms include water quality, sanitation, handwashing, nutrition, combined water+sanitation+handwashing (WSH) and WSH+nutrition. The studies will enrol newborn children (N=5760 in Bangladesh and N=8000 in Kenya) and measure outcomes at 12 and 24 months after intervention delivery. Primary outcomes include child length-for-age Z-scores and caregiver-reported diarrhoea. Secondary outcomes include stunting prevalence, markers of environmental enteropathy and child development scores (verbal, motor and personal/social). We will estimate unadjusted and adjusted intention-to-treat effects using semiparametric estimators and permutation tests. Ethics and dissemination Study protocols have been reviewed and approved by human subjects review boards at the University of California, Berkeley, Stanford University, the International Centre for Diarrheal Disease Research, Bangladesh, the Kenya Medical Research Institute, and Innovations for Poverty Action. Independent data safety monitoring

  17. Water, Sanitation and Hygiene (WASH) and environmental risk factors for soil-transmitted helminth intensity of infection in Timor-Leste, using real time PCR.

    Science.gov (United States)

    Campbell, Suzy J; Nery, Susana V; Wardell, Rebecca; D'Este, Catherine A; Gray, Darren J; McCarthy, James S; Traub, Rebecca J; Andrews, Ross M; Llewellyn, Stacey; Vallely, Andrew J; Williams, Gail M; Clements, Archie C A

    2017-03-01

    No investigations have been undertaken of risk factors for intensity of soil-transmitted helminth (STH) infection in Timor-Leste. This study provides the first analysis of risk factors for intensity of STH infection, as determined by quantitative PCR (qPCR), examining a broad range of water, sanitation and hygiene (WASH) and environmental factors, among communities in Manufahi District, Timor-Leste. A baseline cross-sectional survey of 18 communities was undertaken as part of a cluster randomised controlled trial, with additional identically-collected data from six other communities. qPCR was used to assess STH infection from stool samples, and questionnaires administered to collect WASH, demographic, and socioeconomic data. Environmental information was obtained from open-access sources and linked to infection outcomes. Mixed-effects multinomial logistic regression was undertaken to assess risk factors for intensity of Necator americanus and Ascaris infection. 2152 participants provided stool and questionnaire information for this analysis. In adjusted models incorporating WASH, demographic and environmental variables, environmental variables were generally associated with infection intensity for both N. americanus and Ascaris spp. Precipitation (in centimetres) was associated with increased risk of moderate-intensity (adjusted relative risk [ARR] 6.1; 95% confidence interval [CI] 1.9-19.3) and heavy-intensity (ARR 6.6; 95% CI 3.1-14.1) N. americanus infection, as was sandy-loam soil around households (moderate-intensity ARR 2.1; 95% CI 1.0-4.3; heavy-intensity ARR 2.7; 95% CI 1.6-4.5; compared to no infection). For Ascaris, alkaline soil around the household was associated with reduced risk of moderate-intensity infection (ARR 0.21; 95% CI 0.09-0.51), and heavy-intensity infection (ARR 0.04; 95% CI 0.01-0.25). Few WASH risk factors were significant. In this high-prevalence setting, strong risk associations with environmental factors indicate that anthelmintic

  18. Renovation work at Restaurant 1

    CERN Multimedia

    2006-01-01

    Due to the age of the present kitchen and freeflow installations in Restaurant 1, essential renovation work is due to be carried out. The work is scheduled to last from September 2006 to May 2007. Work on the self-service area of the restaurant will commence in November. Every effort will be made to minimise the inconvenience caused to users of the restaurant and we thank you in advance for your co-operation during this period.

  19. Renovation works at Restaurant 1

    CERN Document Server

    2006-01-01

    Due to the age of the present kitchen and freeflow installations in Restaurant 1, essential renovations are due to be carried out. The planned period for this project is September 2006 to May 2007. Work on the self-service area of the restaurant will commence in November. Every effort will be made to minimise the inconvenience caused to users of the restaurant and we thank you in advance for your co-operation during this period.

  20. The early design stage for building renovation with a novel loop-heat-pipe based solar thermal facade (LHP-STF) heat pump water heating system: Techno-economic analysis in three European climates

    International Nuclear Information System (INIS)

    Zhang, Xingxing; Shen, Jingchun; Adkins, Deborah; Yang, Tong; Tang, Llewellyn; Zhao, Xudong; He, Wei; Xu, Peng; Liu, Chenchen; Luo, Huizhong

    2015-01-01

    rate of return method (IRR). Four common investment options were considered in this business model, including buying outright (BO), buying by instalment (BI), energy efficiency funding (EEF) and power purchase agreement (PPA). The research results indicate that the LHP-STF could contribute to the hot water load throughout the year with substantially reduced heating load in winter, and yet a slight increased cooling load in summer. Among four investment options, the BO was considered as the best investment method with the highest NPV, IRR and the shortest payback period. With regards to relatively limited solar resources, London was found to be the best place for investment with the highest economical revenues and an attractive payback period of less than four years for all purchase options. Although Madrid has the richest solar resource, this system has the lowest economic profit and the longest payback period. This outcome confirms that the renewable energy incentives have a higher impact than solar resources on current solar thermal facade technologies under such pricing fundamentals. This multidisciplinary research is expected to be helpful for the strategic decisions at the early design stage for building renovation with the proposed system and further promote development of solar driven service system, leading to the savings in fossil fuel consumption and reduction in carbon emission.

  1. Numerical model for a watering plan to wash out organic matter from the municipal solid waste incinerator bottom ash layer in closed system disposal facilities.

    Science.gov (United States)

    Ishii, Kazuei; Furuichi, Toru; Tanikawa, Noboru

    2009-02-01

    Bottom ash from municipal solid waste incineration (MSWI) is a main type of waste that is landfilled in Japan. The long-term elution of organic matter from the MSWI bottom ash layers is a concern because maintenance and operational costs of leachate treatment facilities are high. In closed system disposal facilities (CSDFs), which have a roof to prevent rainfall from infiltrating into the waste layers, water must be supplied artificially and its quantity can be controlled. However, the quantity of water needed and how to apply it (the intensity, period and frequency) have not been clearly defined. In order to discuss an effective watering plan, this study proposes a new washout model to clarify a fundamental mechanism of total organic carbon (TOC) elution behavior from MSWI bottom ash layers. The washout model considers three phases: solid, immobile water and mobile water. The parameters, including two mass transfer coefficients of the solid-immobile water phases and immobile-mobile water phases, were determined by one-dimensional column experiments for about 2 years. The intensity, period and frequency of watering and other factors were discussed based on a numerical analysis using the above parameters. As a result, our washout model explained adequately the elution behavior of TOC from the MSWI bottom ash layer before carbonation occurred (pH approximately 8.3). The determined parameters and numerical analysis suggested that there is a possibility that the minimum amount of water needed for washing out TOC per unit weight of MSWI bottom ash layer could be determined, which depends on the two mass transfer coefficients and the depth of the MSWI bottom ash layer. Knowledge about the fundamental mechanism of the elution behavior of TOC from the MSWI bottom ash layer before carbonation occurs, clarified by this study, will help an effective watering plan in CSDFs.

  2. The fire brigade renovates

    CERN Multimedia

    2002-01-01

    The new fire engine at CERN's Fire Station. A shiny brand-new fire engine is now attracting all the attention of the members of CERN's fire brigade. Since the beginning of last week this engine has taken over from an 18-year-old one, which has now been 'retired' from service. This modern vehicle, built in Brescia, Italy, is much lighter and more powerful than the old one and is equipped to allow the fire service to tackle most call-outs without the support of at least one other vehicle, as is currently necessary. The new fire engine is designed to transport six fire-fighters, 2000 litres of water, and is equipped not only for fire fighting actions but also to respond initially to any other kind of call-out, such as traffic accidents, chemical incidents, pollution, lightning, etc. It goes almost without saying that it is provided with the most modern safety measures, a low centre of gravity, as well as a special chassis and a combination pump (low and high pressure), which improve the safety and performance ...

  3. Comparison of the disinfection efficacy of chlorine-based products for inactivation of viral indicators and pathogenic bacteria in produce wash water.

    Science.gov (United States)

    Chaidez, Cristobal; Moreno, Maria; Rubio, Werner; Angulo, Miguel; Valdez, Benigno

    2003-09-01

    Outbreaks of pathogenic bacteria infections associated with the consumption of fresh produce has occurred with increased frequency in recent years. This study was undertaken to determine the efficacy of three commonly used disinfectants in packing-houses of Culiacan, Mexico (sodium hypochlorite [NaOCl], trichlor-s-triazinetrione [TST] and thrichlormelamine [TCM]) for inactivation of viral indicators and pathogenic bacteria inoculated onto produce wash water. Each microbial challenge consisted of 2 L of water containing approximately 8 log10 bacterial CFU ml(-1), and 8 log10 viral PFU ml(-1) treated with 100 and 300 mg l(-1) of total chlorine with modified turbidity. Water samples were taken after 2 min of contact with chlorine-based products and assayed for the particular microorganisms. TST and NaOCl were found to effectively reduce for bacterial pathogens and viral indicators 8 log10 and 7 log10, respectively (alpha=0.05). The highest inactivation rate was observed when the turbidity was low and the disinfectant was applied at 300 mg l(-1). TCM did not show effective results when compared with the TST and NaOCl (Pturbidity created by the organic and inorganic material present in the water tanks carried by the fresh produce may affect the efficacy of the chlorine-based products.

  4. Counter current decantation washing of HLW sludge

    International Nuclear Information System (INIS)

    Brooke, J.N.; Peterson, R.A.

    1997-01-01

    The Savannah River Site (SRS) has 51 High Level Waste (HLW) tanks with typical dimensions 25.9 meters (85 feet) diameter and 10 meters (33 feet) high. Nearly 114 million liters (30 M gallons) of HLW waste is stored in these tanks in the form of insoluble solids called sludge, crystallized salt called salt cake, and salt solutions. This waste is being converted to waste forms stable for long term storage. In one of the processes, soluble salts are washed from HLW sludge in preparation for vitrification. At present, sludge is batch washed in a waste tank with one or no reuse of the wash water. Sodium hydroxide and sodium nitrite are added to the wash water for tank corrosion protection; the large volumes of spent wash water are recycled to the evaporator system; additional salt cake is produced; and sodium carbonate is formed in the washed sludge during storage by reaction with CO 2 from the air. High costs and operational concerns with the current washing process prompts DOE and WSRC to seek an improved washing method. A new method should take full advantage of the physical/chemical properties of sludge, experience from other technical disciplines, processing rate requirements, inherent process safety, and use of proven processes and equipment. Counter current solids washing is a common process in the minerals processing and chemical industries. Washing circuits can be designed using thickeners, filters or centrifuges. Realizing the special needs of nuclear work and the low processing rates required, a Counter Current Decantation (CCD) circuit is proposed using small thickeners and fluidic pumps

  5. Environmental issues associated with R Reactor renovation and startup

    International Nuclear Information System (INIS)

    Marter, W.L.

    1982-01-01

    This memorandum identifies the more significant environmental issues that would be associated with renovation and startup of R Reactor to meet future demands for nuclear weapon materials. Some key environmental issues identified are: potential occupational radiation exposures associated with repairing the leaks in the reactor nozzles and thermal shield tanks and with renovating the disassembly basin facilities; the impacts of constructing additional cooling water pumping capacity; the effect of increased pumping on impingement and entrainment at the pump houses; thermal effects on the R Canal-precooler pond-Par Pond ecosystem from increased discharge of cooling water; and effects of increased water flow in Lower Three Runs Creek on biota and on cesium-137 remobilization

  6. Soil washing for brine removal

    International Nuclear Information System (INIS)

    Ayyachamy, J.S.; Atalay, A.; Zaman, M.

    1992-01-01

    During the exploration for oil and thereafter, brine transfer lines get ruptured releasing the brine which contaminates the surrounding soil. The salinity level in brine is very high, sometimes approaching or exceeding that of sea water. Soils contaminated with brine are unproductive and unsuitable for plant growth. Several investigators have documented the pollution of surface water and groundwater due to brine disposal from oil and needed to clean up such sites. The objective of this study is to develop a soil washing technique that can be used to remove brine sites were collected and used in the study. This paper reports on results which indicate that soil washing using various surface active agents is effective in removing the brine

  7. Microbial contamination of water intended for milk container washing in smallholder dairy farming and milk retailing houses in southern Ethiopia.

    Science.gov (United States)

    Amenu, Kebede; Shitu, Desalew; Abera, Mesele

    2016-01-01

    The water used during handling and processing of milk products can be potential sources of microbial contamination with possible negative consequences on food safety. Especially, the water used in keeping the hygiene of milking and milk storage utensils is crucial to keep the quality and safety of the products. Therefore, the current study was designed to assess the bacteriological quality of water used for cleaning milking and milk storage equipment in smallholder dairy production in Hawassa and its surroundings. A total of 79 water samples were collected: 26 from milk collecting houses in Hawassa and 53 from selected smallholder dairy farms (Hawassa = 14, Arsi Negele = 29 and Yirgalem = 10). Out of the total samples, 18 samples were collected directly from pipe and 61 from storage containers (46 from narrow opening and 15 from wide opening containers). The overall prevalence of E. coli exceeding zero CFU/ml was 39.2 %. From analyzed samples, high prevalence of positive samples for E. coli was found in water samples taken from wide opening containers (66.7 %). A number of bacteria were isolated and presumptively identified which include Bacillus sp. 6.3 % (n = 5), Citrobacter sp. 1.3 %(n = 1), E. coli 39.2 % (n = 31), Enterobacter sp. 2.5 % (n = 2), Klebisella sp. 7.6 % (n = 6), Micrococcus sp. 6.3 % (n = 5), Pseudomonas sp. 6.3 % (n = 5), Staphylococcus aureus 6.3 % (n = 5), Staphylococcus epidermidis 13.9 % (n = 11) and Streptococcus sp. 1.3 % (n = 1). The bacteriological quality of water especially, water stored in household storage containers in present study area was found to be contaminated with different bacteria indicating potential food safety problem and health risk to the society. In this respect, people handling water should be educated on its proper handling and the risk of contamination during storage. To minimize contamination, materials with narrow mouth and lid should be used. Further study is recommended on

  8. 33 CFR 157.124 - COW tank washing machines.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false COW tank washing machines. 157... OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.124 COW tank washing machines. (a) COW machines must be permanently mounted in each cargo tank. (b...

  9. Washing method of filter

    International Nuclear Information System (INIS)

    Izumidani, Masakiyo; Tanno, Kazuo.

    1978-01-01

    Purpose: To enable automatic filter operation and facilitate back-washing operation by back-washing filters used in a bwr nuclear power plant utilizing an exhaust gas from a ventilator or air conditioner. Method: Exhaust gas from an exhaust pipe of an ventilator or air conditioner is pressurized in a compressor and then introduced in a back-washing gas tank. Then, the exhaust gas pressurized to a predetermined pressure is blown from the inside to the outside of a filter to thereby separate impurities collected on the filter elements and introduce them to a waste tank. (Furukawa, Y.)

  10. Promotion of Sustainable Renovation in Europe

    DEFF Research Database (Denmark)

    Fokaides, Paris A.; Kanarachos, Andreas; Kanarachos, Georgette

    2013-01-01

    pressing the energy renovation of buildings. Both the obstacles and the contribution of national regulations will be discussed, towards promotion of sustainable renovation in Europe today. This study is also expected to report on research initiatives currently being undertaken in Europe on the energy...

  11. Renovate Right: Prevent Lead Poisoning in Children

    Centers for Disease Control (CDC) Podcasts

    In this podcast, Dr. Maria Doa, Director of the Environmental Protection Agency's (EPA) National Program Chemicals Division, discusses EPA's new rule for renovations, repairs, and painting activities. The new rule includes information on lead-safe work practices when conducting renovations, repairs, and painting in pre-1978 homes and schools to prevent the spread of lead dust.

  12. Restaurant No. 1 fully renovated

    CERN Document Server

    2007-01-01

    The Restaurant No. 1 team. After several months of patience and goodwill on the part of our clients, we are delighted to announce that the major renovation work which began in September 2006 has now been completed. From 21 May 2007 we look forward to welcoming you to a completely renovated restaurant area designed with you in mind. The restaurant team wishes to thank all its clients for their patience and loyalty. Particular attention has been paid in the new design to creating a spacious serving area and providing a wider choice of dishes. The new restaurant area has been designed as an open-plan space to enable you to view all the dishes before making your selection and to move around freely from one food access point to another. It comprises user-friendly areas that fully comply with hygiene standards. From now on you will be able to pick and choose to your heart's content. We invite you to try out wok cooking or some other speciality. Or select a pizza or a plate of pasta with a choice of two sauces fr...

  13. Building renovations in BIM systems

    Directory of Open Access Journals (Sweden)

    Smutný Marian

    2018-01-01

    Full Text Available Renovation of buildings is a demanding challenge for computer systems. Nowadays, complex 3D models of historic buildings can be scanned and modelled, including sculptural filigrees and stucco decorations with possibility to generate different projections, cross-sections and elevations according to descriptive geometry rules. However, all of this falls within the field of “3D Modelling”. BIM systems work with elements that have to be classified according to their purpose, or according to the way they are realized. The system is then able to sort, filter or group them. Also, it is able to compute their bill of quantity and quality based on their attributes. Last but not least, it has to be able to schematically display civil engineering drawings on the basis of classification of the elements which differ considerably from the display of descriptive geometry. In regular constructions, repeatability and predictability of the links between the elements suit computer systems. Thus, the issue of building renovations in BIM systems is to find a balance between modelling irregular constructions and irregular space arrangements, while maintaining the ability to interact with other BIM elements.

  14. Radiotracer study of wash load movement in a drum-type fabric washing machine using a gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Balt, A.P.; Brekel, L.D.M. van den; Vandecasteele, C.; Kolar, Z.

    1987-01-01

    A study was made of the movement of the wash loads in a drum-type washing machine. For this purpose a sup(99m)Tc source was attached to one or two separate textile pieces and the subsequent source positions were determined by means of a gamma-camera. The wash load movement pattern appears to depend on the type of textile material and its amount, as well as on the volume of water present in the washing machine.

  15. Radiotracer study of wash load movement in a drum-type fabric washing machine using a gamma camera

    International Nuclear Information System (INIS)

    Balt, A.P.; Brekel, L.D.M. van den; Vandecasteele, C.; Kolar, Z.

    1987-01-01

    A study was made of the movement of the wash loads in a drum-type washing machine. For this purpose a sup(99m)Tc source was attached to one or two separate textile pieces and the subsequent source positions were determined by means of a gamma-camera. The wash load movement pattern appears to depend on the type of textile material and its amount, as well as on the volume of water present in the washing machine. (author)

  16. The effects of washing with Tamarind (Tamarindus indica L. water solution on shelf life of silver carp (Hypophthalmichthys molitrix fillet during refrigerator storage

    Directory of Open Access Journals (Sweden)

    Eshagh Zakipour Rahimabadi

    2016-01-01

    Full Text Available This study evaluated the antibacterial and antioxidant effects of tamarind water solution on shelf life of silver carp (Hypophthalmicthys molitrix fillet during refrigerator storage. Treatments of this study were unwashed samples (control, and samples washed with 1% and 2% tamarind water solution. Microbial, physicochemical and sensory analysis including total viable count (TVC, peroxide value (PV, thiobarbituric acid (TBA, total volatile base (TVB-N and pH were measured during 15 day storage at refrigerator (with 3 days intervals. Proximate analysis of samples also measured at day 0. TVC content was 0.93, 0.50 and 0.10 log CFU/g for control and treatments 1% and 2%, respectively and reached to 6.24, 5.82 and 5.21 log CFU/g at the end of storage period. At the end of storage period, the PV, TBA and TVB-N content were 8.4, 4.3, and 3.0 meq O2/Kg for control, 2.75, 1.35, and 0.50 mg/100g for 1% treatment, and 33.17, 23.90, and 22.10 mg N/100g for 2% treatment, respectively. This results showed the positive effect of tamarind to inhibit and delay fish fillet spoilage. According to sensory evaluation, the density of 1% tamarind was selected as the best density.

  17. A cluster-randomised controlled trial integrating a community-based water, sanitation and hygiene programme, with mass distribution of albendazole to reduce intestinal parasites in Timor-Leste: the WASH for WORMS research protocol

    Science.gov (United States)

    Nery, Susana Vaz; McCarthy, James S; Traub, Rebecca; Andrews, Ross M; Black, Jim; Gray, Darren; Weking, Edmund; Atkinson, Jo-An; Campbell, Suzy; Francis, Naomi; Vallely, Andrew; Williams, Gail; Clements, Archie

    2015-01-01

    Introduction There is limited evidence demonstrating the benefits of community-based water, sanitation and hygiene (WASH) programmes on infections with soil-transmitted helminths (STH) and intestinal protozoa. Our study aims to contribute to that evidence base by investigating the effectiveness of combining two complementary approaches for control of STH: periodic mass administration of albendazole, and delivery of a community-based WASH programme. Methods and analysis WASH for WORMS is a cluster-randomised controlled trial to test the hypothesis that a community-based WASH intervention integrated with periodic mass distribution of albendazole will be more effective in reducing infections with STH and protozoa than mass deworming alone. All 18 participating rural communities in Timor-Leste receive mass chemotherapy every 6 months. Half the communities also receive the community-based WASH programme. Primary outcomes are the cumulative incidence of infection with STH. Secondary outcomes include the prevalence of protozoa; intensity of infection with STH; as well as morbidity indicators (anaemia, stunting and wasting). Each of the trial outcomes will be compared between control and intervention communities. End points will be measured 2 years after the first albendazole distribution; and midpoints are measured at 6 months intervals (12 months for haemoglobin and anthropometric indexes). Mixed-methods research will also be conducted in order to identify barriers and enablers associated with the acceptability and uptake of the WASH programme. Ethics and dissemination Ethics approval was obtained from the human ethics committees at the University of Queensland, Australian National University, Timorese Ministry of Health, and University of Melbourne. The results of the trial will be published in peer-reviewed journals presented at national and international conferences, and disseminated to relevant stakeholders in health and WASH programmes. This study is funded

  18. Renovation of historic, protected buildings in Geneva

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W.; Haefeli, P.

    2009-07-01

    This report for the Swiss Federal Office of Energy (SFOE) reports on work done within the IEA Solar Heating and Cooling Program's Task 37. The objective of SHC Task 37 is to develop a solid knowledge base on how to renovate housings to a very high energy standard and how to develop strategies that support the market penetration of such renovation methods. The report deals with four listed buildings of historical value in Geneva, Switzerland, and examines various aspects of the renovation. These aspects include a discussion of the techniques applied, including internal and external insulation. Simulation methods used and results obtained are discussed. The improvements made are evaluated.

  19. Energy renovation solutions - catalogue; Energirenoveringstiltag - katalog

    Energy Technology Data Exchange (ETDEWEB)

    Tommerup, H.

    2010-07-15

    The project's aim has been to develop methods and examples of extensive energy renovations to stimulate energy conservation and increased use of renewable energy in existing buildings. The current report represents an extensive technology catalogue of typical energy renovation measures in connection with the renovation of existing buildings. For every action the main aspects are explained concerning such issues as technology, use, barriers, indoor climate, energy conservation and prices. The report is mainly targeted at construction industry, but also many other stakeholders can benefit from the report. (ln)

  20. Pollutants Characterization of Car Wash Wastewater

    Directory of Open Access Journals (Sweden)

    Hashim Nor Haslina

    2016-01-01

    Full Text Available The huge quantity of water consumed per car during washing cars yields the untreated effluents discharged to the stormwater system. Wastewater samples from snow car wash and two full hand service car wash station were analyzed for pH and the presence of PO43-,TP, O&G, alkalinity, TSS, NO3-, NO2-, COD and surfactant in accordance Standard Method of Water and Wastewater 2012. Two full hand wash service stations and one station of snow foam service were investigated in this study. Amongst the stations, snow foam car wash station indicates the highest concentration of PO43-, TP, O&G, TSS, COD and surfactant with the average value of 10.18 ± 0.87 mg/L, 30.93 ± 0.31 mg/L , 85.00 ± 0.64 mg/L 325.0 ± 0.6 mg/L, 485.0 ± 0.3 mg/L and 54.00 ± 2.50 mg/L as MBAS, respectively. Whereas, in parameters characterization in different stages throughout the car wash process, O&G was found to be the highest in pre soak stage, PO43-, TP, TSS and COD in washing stage and NO3- and NO2- in rinse stage. All parameters were compared to Environmental Quality (Industrial Effluent Regulations, 2009. There is a strong need to study on the characterization of car wash water in order to suggest the suitable treatment need for this type of wastewater.

  1. Probabilistics since WASH-1400

    International Nuclear Information System (INIS)

    Whitehead, N.E.

    1980-01-01

    Literature since the issuing of WASH-1400 reactor safety study shows that although the methodology has been attacked, it stands criticism well. Contrary to the aim of the study, which was to give a realistic, rather than a conservative risk estimate, there are many conservatisms in it. The strongly attacked treatment of common mode failure involving the square bounding model is shown here to be very likely to give correct results - and the applications of it in WASH-1400 do not often give results different from using the mean instead of the median. The Three-Mile Island accident is not such as to change the conclusions of WASH-1400 regarding core melt probabilities

  2. Soil washing technology evaluation

    International Nuclear Information System (INIS)

    Suer, A.

    1995-04-01

    Environmental Restoration Engineering (ERE) continues to review innovative, efficient, and cost effective technologies for SRS soil and/or groundwater remediation. As part of this effort, this technical evaluation provides review and the latest information on the technology for SRS soil remediation. Additional technology evaluation reports will be issued periodically to update these reports. The purpose of this report is to review the soil washing technology and its potential application to SRS soil remediation. To assess whether the Soil Washing technology is a viable option for SRS soil remediation, it is necessary to review the technology/process, technology advantages/limitations, performance, applications, and cost analysis

  3. Analysis of promising sustainable renovation concepts

    DEFF Research Database (Denmark)

    Vanhoutteghem, Lies; Tommerup, Henrik M.; Svendsen, Svend

    This report focuses on analyses of the most promising existing sustainable renovation concepts, i.e. full-service concepts and technical concepts, for single-family houses. As a basis for the analyses a detailed building stock analysis was carried out. Furthermore, as a basis a general working...... method for proposals on package solutions for sustainable renovation was described. The method consists of four steps, going from investigation of the house to proposal for sustainable renovation, detailed planning and commissioning after renovation. It could be used by teams of consultants...... of the building envelope and the electricity required to run the system. Positive impact on the indoor environment can be expected. Thermal comfort will be improved by insulation and air-tightness measures that will increase surface temperatures and reduce draught from e.g. badly insulated windows. A ventilation...

  4. Collaboration opportunities in advanced housing renovation

    DEFF Research Database (Denmark)

    Mlecnik, Erwin; Kondratenko, Irena; Cré, Johan

    2012-01-01

    demand for integrated renovations has to be stimulated. A research and networking methodology was developed within the framework of the One Stop Shop project to identify and develop collaboration opportunities for advanced housing renovation in Belgium, Denmark, Finland and Norway. The research...... identified key supply-side needs through interviews and questionnaires, and analysed important elements for the development of a web-based portal that can connect supply and demand. The project further developed ideas and methods for collaboration and business model generation between different players...... on the renovation market. These different research results contributed to defining new business opportunities related to process innovation to unburden the homeowner and to achieve less fragmented renovation processes...

  5. Funding of Facility Repairs and Renovation.

    Science.gov (United States)

    Kaiser, Harvey H.

    1984-01-01

    Compares the life cycle approach for campus building repair and renovation to the University of California's comprehensive building maintenance formula and advises that formulas be used cautiously as a method of determining appropriate budget levels. (MLF)

  6. Application of solar energy to the supply of industrial process hot water: preliminary design and performance report. Volume I. Technical report. Aerotherm report TR-76-219. [For can washing at Campbell Soup Plant in Sacramento

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-10-14

    The design and performance of a solar hot water system for can washing at the Campbell Soup Plant in Sacramento, California, are presented. The collector field is located on the roof of the finished products warehouse of the Campbell Soup Sacramento plant. Water is supplied from a 3.8 cm (1/sup 1///sub 2/ in.) supply line which is located directly below an existing roof access hatch. A supply pipe will be brought up through that hatch. The water flow will then be split into two manifold lines which supply the dual rows of flat plate collectors. The preheated water from the flat plates is then passed into six sets of parallel connected concentrators. Each set consist of eight 1.83 x 3.05 m (6 x 10 foot) modules connected in series. The water from these units is gathered in a 3.8 cm (1/sup 1///sub 2/ in.) insulated pipe which transports it to the storage tank. This pipe will be attached to an existing pipe run until it reaches the can washing building. From there the pipe will follow the can washing building around to the storage tank. The storage tank is a 75,200 1 (20,000 gal) steel tank which is coated internally with a USDA approved phenolic liner. The outside of the tank is insulated. A 2.2 kw (3 hp) motor is used to pump the stored water for the tank into the can washing line. Detail drawings and descriptions of the collector field, installation, piping, controls, data acquisition equipment, and roof structure are included. Furthermore, a program schedule with equipment and manpower costs for successfully completing Phase II of this contract is included. Also included is an organization chart of the Phase II program personnel. (WHK)

  7. Renovate Right: Prevent Lead Poisoning in Children

    Centers for Disease Control (CDC) Podcasts

    2008-10-02

    In this podcast, Dr. Maria Doa, Director of the Environmental Protection Agency's (EPA) National Program Chemicals Division, discusses EPA's new rule for renovations, repairs, and painting activities. The new rule includes information on lead-safe work practices when conducting renovations, repairs, and painting in pre-1978 homes and schools to prevent the spread of lead dust.  Created: 10/2/2008 by National Center for Environmental Health (NCEH).   Date Released: 10/2/2008.

  8. An integrated urban drainage system model for assessing renovation scheme.

    Science.gov (United States)

    Dong, X; Zeng, S; Chen, J; Zhao, D

    2012-01-01

    Due to sustained economic growth in China over the last three decades, urbanization has been on a rapidly expanding track. In recent years, regional industrial relocations were also accelerated across the country from the east coast to the west inland. These changes have led to a large-scale redesign of urban infrastructures, including the drainage system. To help the reconstructed infrastructures towards a better sustainability, a tool is required for assessing the efficiency and environmental performance of different renovation schemes. This paper developed an integrated dynamic modeling tool, which consisted of three models for describing the sewer, the wastewater treatment plant (WWTP) and the receiving water body respectively. Three auxiliary modules were also incorporated to conceptualize the model, calibrate the simulations, and analyze the results. The developed integrated modeling tool was applied to a case study in Shenzhen City, which is one of the most dynamic cities and facing considerable challenges for environmental degradation. The renovation scheme proposed to improve the environmental performance of Shenzhen City's urban drainage system was modeled and evaluated. The simulation results supplied some suggestions for the further improvement of the renovation scheme.

  9. Wash Your Hands

    Centers for Disease Control (CDC) Podcasts

    2010-03-08

    This video shows kids how to properly wash their hands, one of the most important steps we can take to avoid getting sick and spreading germs to others.  Created: 3/8/2010 by Centers for Disease Control and Prevention (CDC).   Date Released: 3/8/2010.

  10. Soil washing treatability study

    International Nuclear Information System (INIS)

    Krstich, M.

    1995-12-01

    Soil washing was identified as a viable treatment process option for remediating soil at the FEMP Environmental Management Project (FEMP). Little information relative to the specific application and potential effectiveness of the soil washing process exists that applies to the types of soil at the FEMP. To properly evaluate this process option in conjunction with the ongoing FEMP Remedial Investigation/Feasibility Study (RI/FS), a treatability testing program was necessary to provide a foundation for a detailed technical evaluation of the viability of the process. In August 1991, efforts were initiated to develop a work plan and experimental design for investigating the effectiveness of soil washing on FEMP soil. In August 1992, the final Treatability Study Work Plan for Operable Unit 5: Soil Washing (DOE 1992) was issued. This document shall be referenced throughout the remainder of this report as the Treatability Study Work Plan (TSWP). The purpose of this treatability study was to generate data to support initial screening and the detailed analysis of alternatives for the Operable Unit 5 FS

  11. Radionuclide content of Las Vegas wash sediments

    International Nuclear Information System (INIS)

    Rudin, M.J.; Meyers, A.M.; Johnson, W.H.

    1996-01-01

    The Las Vegas Wash is an excavated waterway channel which drains all surface water and effluent discharge from sewage-treatment facilities from the greater Las Vegas Metropolitan Area to Lake Mead. Runoff and erosion processes are expected to transport man-made radioactivity that was deposited over the past several decades in the Las Vegas Valley. Additionally, radionuclides disposed of via the city's sanitary system are expected to accumulate in the Wash sediments. Fine and coarse sediment samples were collected at 100 m intervals and analyzed to determine the distribution of alpha- and gamma-emitting radionuclides in the lower 5,500 in of the Las Vegas Wash. Results indicate little accumulation of long-lived fission products in upstream Wash sediments. However, trace amounts of fission products measured in downstream sediments suggest the resuspension and transport of radioactive particulate matter within the Wash. Levels of naturally-occurring radionuclides found in Wash sediments were found to be consistent with levels typically found in southeast Nevada soils

  12. Wash-oil problem

    Energy Technology Data Exchange (ETDEWEB)

    Chlosta, J

    1941-01-01

    Meier-Grolman and others have deduced from experimental studies of the vapor pressure of solutions of benzene in paraffin oil and Solway oil-paraffin oil mixtures that the higher the proportion of aliphatic compounds in a wash oil, the less suitable it is for benzene scrubbing. This generalization is not supported. Paraffin oils from brown-coal tar and low viscous oils from the Fischer-Tropsch hydrocarbon synthesis process are both being successfully used for benzene scrubbing.

  13. A cluster-randomised controlled trial integrating a community-based water, sanitation and hygiene programme, with mass distribution of albendazole to reduce intestinal parasites in Timor-Leste: the WASH for WORMS research protocol.

    Science.gov (United States)

    Nery, Susana Vaz; McCarthy, James S; Traub, Rebecca; Andrews, Ross M; Black, Jim; Gray, Darren; Weking, Edmund; Atkinson, Jo-An; Campbell, Suzy; Francis, Naomi; Vallely, Andrew; Williams, Gail; Clements, Archie

    2015-12-30

    There is limited evidence demonstrating the benefits of community-based water, sanitation and hygiene (WASH) programmes on infections with soil-transmitted helminths (STH) and intestinal protozoa. Our study aims to contribute to that evidence base by investigating the effectiveness of combining two complementary approaches for control of STH: periodic mass administration of albendazole, and delivery of a community-based WASH programme. WASH for WORMS is a cluster-randomised controlled trial to test the hypothesis that a community-based WASH intervention integrated with periodic mass distribution of albendazole will be more effective in reducing infections with STH and protozoa than mass deworming alone. All 18 participating rural communities in Timor-Leste receive mass chemotherapy every 6 months. Half the communities also receive the community-based WASH programme. Primary outcomes are the cumulative incidence of infection with STH. Secondary outcomes include the prevalence of protozoa; intensity of infection with STH; as well as morbidity indicators (anaemia, stunting and wasting). Each of the trial outcomes will be compared between control and intervention communities. End points will be measured 2 years after the first albendazole distribution; and midpoints are measured at 6 months intervals (12 months for haemoglobin and anthropometric indexes). Mixed-methods research will also be conducted in order to identify barriers and enablers associated with the acceptability and uptake of the WASH programme. Ethics approval was obtained from the human ethics committees at the University of Queensland, Australian National University, Timorese Ministry of Health, and University of Melbourne. The results of the trial will be published in peer-reviewed journals presented at national and international conferences, and disseminated to relevant stakeholders in health and WASH programmes. This study is funded by a Partnership for Better Health--Project grant from the National

  14. Distinctiveness of Initial Preform Properties in Renovation

    Directory of Open Access Journals (Sweden)

    V. M. Yaroslavtsev

    2015-01-01

    Full Text Available Technologies of renovation form a special group of resource-and energy saving technological processes as they are, by definition, already aimed either at increasing resource of the objects satisfying needs of the society life support and practical activities in different spheres, or at extension of their life cycle including a reuse of material from which they are made. Renovation is used where there is a material object, which does not meet requirements of standard or technical documentation.A characteristic feature of the renovation technologies is lack of procedure for a choice of the preform as in all cases an initial preform is the renovation object itself. Thus each object, acting as an initial preform, has the exclusively individual properties, including technological ones.Distinctiveness of renovation object properties is correlated, first of all, with the personified conditions of formation and (or change of condition of their properties in time at all stages of life cycle (production – transportation – warehousing – operation starting with a preform material when manufacturing under all types of loadings (technological and operational. As a result each object forms its "history" of loading and damages and, therefore, its information base which has to consider the phenomenon of “heredity of life cycle”. The term "heredity of life cycle" characterizes information support of object at any moment under review, including both information of technological inheritance, and data of operational heredity.As a result at every moment of time we have a product with a set of new, uncertain properties caused by the phenomena of heredity of life cycle. These properties are individual for each object to be renovated, which changed its status for the status of initial preform for different types of renovation technologies. This is one of the most important distinctions of renovation technology from the technology used to manufacture a new

  15. Dwelling thermal renovation: which stakes, which solutions?

    International Nuclear Information System (INIS)

    Delduc, Paul; Demeulenaere, Laurence; Verdure, Mathieu; Ayong Le Kama, Alain; Fuk Chun Wing, Dimitri; Kiefer, Noemie; Mauroux, Amelie; Charlier, Dorothee; Hini, Sihame; Pinto Silva, Kleber; Giraudet, Louis Gaetan; Nauleau, Marie-Laure; Daussin-Benichou, Jeanne-Marie; Teissier, Olivier; Finidori, Esther; Grandjean, Alain; Allibe, Benoit; Gadrat, Pierre; Couriol, Aude; Menard, Francois; Rouquette, Celine; Houriez, Guillaume; Francois, Dominique; Aubert, Celine; Canardon, Daniel

    2015-01-01

    This publication proposes three sets of contributions. The first one addresses context and stakes. The contributions propose: a literature review on household behaviour and investments in energy efficiency, a focus on the key role of dwellings in energy transition through a comparative study of the four pathways of the National Debate for Energy Transition, and a discussion about consensus and uncertainties regarding the determining factors of heating temperature in dwellings. The second set addresses public policies and their assessment: improvement of the technical-economical assessment of the benefit of dwelling energetic renovations, discussion of the organisation and results of a survey on dwelling, equipment, and energy needs and uses, an analysis of several measures aimed at reaching objectives of energy efficiency of dwellings, a discussion of renovation works quality, a discussion of the impact of the sustainable development tax credit on thermal renovation, the optimisation of energy renovation in co-properties by third party financing, some foreign examples of policies in favour of dwelling thermal renovation. The third set of contributions addresses the needed technical, organisational and market evolutions: how the building sector can face the challenges of energy transition, the possibilities to propose innovative solutions adapted to existing housing buildings, and a comparative analysis of material and building equipment costs and market structures in Europe. Other texts are proposed in appendix: the origin of the Phebus survey, a description of incentive arrangements, and a map of climate zones in France

  16. Kinds of initial billets in renovation technologies

    Directory of Open Access Journals (Sweden)

    V. M. Yaroslavtsev

    2014-01-01

    Full Text Available Nowadays, technologists in charge of repair, restoration, modernization, and utilization of engineering and other tangible objects widely use the concepts "renovation" and "renovation technologies" pioneered at BMSTU. In forming a new field of science these concepts, in the proper sense of the word, are of composite, generalized character. They concern all the activities and technologies aimed at increasing an object resource or its lifecycle extension, including object material recycling.In the cutting-edge renovation technologies an object (part, assembly, machine, etc. damaged in the operating process is considered to be an initial billet. In renovation, one of the most widespread kinds of initial billets is a damaged part.Such a part can be used again, if, for example, it has saved its material properties in full measure while only contact surfaces or parts of these surfaces have become damaged, and at a point of renovation they can be restored for recycling. If a part has lost its initial properties in full bulk of material, it may be reusable in the assemblies and machines with less rigid requirements for material properties.Or in case of properties loss below the permissible level a damaged part-billet is utilized. Thus, the part-billet state at the point of renovation defines the kind of renovation technology and the main (basic technological method to effect on the damaged part, as well as a set and a sequence of technological methods in general manufacturing process of renovation.However renovation technologies are used not only at the repair and restoration stages after operation-service. So, at the manufacturing stage of a new product to provide the quality to raise a resource are applied the same technological methods as renovation technologies for the objects damaged at the stage of operation. Besides, it is known that at the manufacturing stage a part quality depends not only on the last operation, but also on the features of

  17. Renovation of the Stockholm sewerage system

    International Nuclear Information System (INIS)

    Sandin, Paer

    1987-01-01

    Within a few years Stockholm will let all its treated wastewater into the Saltsjoen. The Saltsjoen is the inner part of the Stockholm Archipelago, which is one of the finest recreation areas in Sweden and where many Stockholmians spend a great deal of their leisure time. That is one reason why it is so important that all wastewater is treated before it reaches the recipient. A sewerage system in bad condition means that the risk of not allowed/unplanned overflows is increased. In order to prevent overflows we drafted 'Plan 83' which tells us how our sewerage system shall be constructed in the future and what measures has to be made in the system. Renovations of the existing pipes is one method to get a well functioning sewer system. Today we have made about 50 different objects at a total length of 6000 m. Why do we renovate sewers and why are we attempting to develop methods for pipe renovations?

  18. Energy Efficient Renovation of Social Housing

    DEFF Research Database (Denmark)

    Bech-Nielsen, Grith; Christiansen, Michael

    In years to come the social housing sector (SH) must undergo renovation. The SH is out of step with modern requirements when it comes to plan arrangements, energy frame calcu-lation, flexible building services and social challenges. A way to solve such challenges in an environmentally, economically......, such as residents, housing administration, politicians, advi-sors, producers and contractors. Secondly we present follow up methods for developing an overall future energy renova-tion SH strategy. Our project contributes to the building sector by suggesting new methods for meeting challenges concerning energy......), (2) workshops and (3) seminars for qualifying (4) the definition of a common framework for (5) the development and (6) acceptance of the actual energy renovation strategy, which will then be transformed into action plans in the form of (7) ”common screening” of housing and housing areas as a basis...

  19. Bæredygtige systemleverancer ved renovering

    DEFF Research Database (Denmark)

    Schipull Kauschen, Jan

    2014-01-01

    System (PSS). This thesis presents the hypothesis that system deliveries may be cast as Product-Service Systems, creating the pre-conditions for sustainable integrated product deliveries. Case Studies Renovation case studies have evinced partial use of system deliveries in recent years; however......-of-sales er dermed relevant for bæredygtige leverancer, der disse kræver at ansvaret forbliver hos systemejeren over leverancens hele livscyklus, fra produktion til bortskaffelsen. Denne type produkt kendes fra andre områder under navnet Product-Service-System (PSS). I afhandlingen opstilles derfor hypotesen...... om at systemleverancer kan udformes som Product-Service-Systems og at dermed skabes forudsætningerne for bæredygtige systemleverancer. Casestudier Casestudier om renovering har desuden vist, at der til dels anvendes systemleverancer til renovering i de sidste år, men at disse leverancer sjældent er...

  20. WASH and gender in health care facilities: The uncharted territory.

    Science.gov (United States)

    Kohler, Petra; Renggli, Samuel; Lüthi, Christoph

    2017-11-08

    Health care facilities in low- and middle-income countries are high-risk settings, and face special challenges to achieving sustainable water, sanitation, and hygiene (WASH) services. Our applied interdisciplinary research conducted in India and Uganda analyzed six dimensions of WASH services in selected health care facilities, including menstrual hygiene management. To be effective, WASH monitoring strategies in health care facilities must include gender sensitive measures. We present a novel strategy, showing that applied gender sensitive multitool assessments are highly productive in assessments of WASH services and facilities from user and provider perspectives. We discuss its potential for applications at scale and as an area of future research.

  1. Fabulous Facilities: New Constructions and Renovations.

    Science.gov (United States)

    American Libraries, 1997

    1997-01-01

    Renovation and construction projects in 18 public and academic libraries across the United States are showcased, with 23 photographs illustrating library interiors and exteriors. Discussion centers on architecture, costs, technology infrastructure and equipment, preservation of old facilities, furniture, and library functions. (AEF)

  2. Chances and barriers for passive house renovations

    NARCIS (Netherlands)

    Mlecnik, E.; Opstelten, I.; Rovers, R.; Verdeyen, N.; Wagenaar, A.

    2016-01-01

    There is significant potential for carbon reduction and energy saving in residential buildings. Various market actors are looking for ways to increase the uptake of passive house renovation and its certification.
    This study aimed specifically to draw lessons from research projects towards the

  3. Renovation of the CERN Computer Centre

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The Computer Centre at CERN is seen after half of the equipment is the large ground floor room has been removed. A large-scale spring-cleaning operation took place before renovation work for the new CERN Grid system began. Fifteen kilometres of cables that were no longer needed were removed from the cavity floor for recycling.

  4. 75 FR 6383 - Lead-Based Paint Renovation, Repair and Painting, and Pre-Renovation Education Activities in...

    Science.gov (United States)

    2010-02-09

    ..., Repair and Painting, and Pre- Renovation Education Activities in Target Housing and Child Occupied....C. 2682(c)(3), and a lead-based paint pre-renovation education program in accordance with section... TSCA, and a lead-based paint pre-renovation education program in accordance with section 406(b) of TSCA...

  5. 76 FR 27044 - Lead-Based Paint Renovation, Repair and Painting, and Pre-Renovation Education Activities in...

    Science.gov (United States)

    2011-05-10

    ..., Repair and Painting, and Pre- Renovation Education Activities in Target Housing and Child Occupied...), and a lead-based paint pre-renovation education program in accordance with section 406(b) of TSCA, 15... renovation and remodeling activities of pre-1978 housing and child-occupied facilities in the State of...

  6. Design and optimisation of purification procedure for biodiesel washing

    Directory of Open Access Journals (Sweden)

    S.B. Glišić

    2009-09-01

    Full Text Available Almost complete methanolysis of triglycerides is usually not enough to fulfil the strict standards of biodiesel quality. A key step in this process is neutralization of alkali (catalyst followed by the washing procedure necessary for removing different impurities such as traces of catalyst and methanol and removal of soaps and glycerol from esters phase. The washing with hot water is still widely used in many industrial units for the biodiesel production. In this study, different procedures of biodiesel washing using hot water were investigated. The orto-phosphoric acid was suggested as the best compound for alkali catalyst (sodium hydroxide neutralization. The main goal of the performed analysis was to minimize the water usage in the washing-neutralization step during the biodiesel production. Such solution would make the process of biodiesel synthesis more economical taking into account the decrease of energy consumed for evaporation of water during the final product purification, as well as more acceptable procedure related to the impact on environment (minimal waste water release. Results of the performed simulation of the washing process supported by original experimental data suggested that neutralization after the optimized washing process of the methyl ester layer could be the best solution. The proposed washing procedure significantly decreases the amount of waste water giving at the same time the desired purity of final products (biodiesel and glycerol. The simulation of the process was performed using ASPEN plus software supported by ELCANTREL and UNIQUAC procedure of required properties calculation

  7. Hand washing promotion for preventing diarrhoea

    Science.gov (United States)

    Ejemot-Nwadiaro, Regina I; Ehiri, John E; Arikpo, Dachi; Meremikwu, Martin M; Critchley, Julia A

    2015-01-01

    -risk population showed significant reduction in mean episodes of diarrhoea (1.68 fewer) in the intervention group (Mean difference 1.68, 95% CI 1.93 to 1.43; one trial, 148 participants, moderate quality evidence). There was increase in hand washing frequency, seven times per day in the intervention group versus three times in the control in this hospital trial (one trial, 148 participants, moderate quality evidence). We found no trials evaluating or reporting the effects of hand washing promotions on diarrhoea-related deaths, all-cause-under five mortality, or costs. Authors' conclusions Hand washing promotion probably reduces diarrhoea episodes in both child day-care centres in high-income countries and among communities living in LMICs by about 30%. However, less is known about how to help people maintain hand washing habits in the longer term. PLAIN LANGUAGE SUMMARY Hand washing promotion for preventing diarrhoea Review question This Cochrane Review summarises trials evaluating the effects of promoting hand washing on the incidence of diarrhoea among children and adults in day-care centres, schools, communities, or hospitals. After searching for relevant trials up to 27 May 2015, we included 22 randomized controlled trials conducted in both high-income countries (HICs) and low- and middle-income countries (LMICs). These trials enrolled 69,309 children and 148 adults. How does hand washing prevent diarrhoea and how might hand washing be promoted Diarrhoea causes many deaths in children below five years of age, mostly in LMICs. The organisms causing diarrhoea are transmitted from person to person through food and water contaminated with faeces, or through person-to-person contact. Hand washing after defecation, or after cleaning a baby's bottom, and before preparing and eating food, can therefore reduce the risk of diarrhoea. Hand washing can be promoted through group or individual training on hygiene education, germ-health awareness, use of posters, leaflets, comic books

  8. Sludge pretreatment chemistry evaluation: Enhanced sludge washing separation factors

    International Nuclear Information System (INIS)

    Colton, N.G.

    1995-03-01

    This report presents the work conducted in Fiscal Year 1994 by the Sludge Pretreatment Chemistry Evaluation Subtask for the Tank Waste Remediation System (TWRS) Tank Waste Treatment Science Task. The main purpose of this task, is to provide the technical basis and scientific understanding to support TWRS baseline decisions and actions, such as the development of an enhanced sludge washing process to reduce the volume of waste that will require high-level waste (HLW) vitrification. One objective within the Sludge Pretreatment Chemistry Evaluation Subtask was to establish wash factors for various SST (single-shell tank) sludges. First, analytical data were compiled from existing tank waste characterization reports. These data were summarized on tank-specific worksheets that provided a uniform format for reviewing and comparing data, as well as the means to verify whether the data set for each tank was complete. Worksheets were completed for 27 SST wastes. The analytical water wash data provided tank-specific information about the fraction of each component that dissolves with water, i.e., an estimate of tank-specific wash factors for evaluating tank-by-tank processing. These wash data were then used collectively to evaluate some of the wash factors that are assumed for the overall SST waste inventory; specifically, wash factors for elements that would be found primarily in sludges. The final step in this study was to incorporate the characterization and wash factor data into a spreadsheet that provides insight into the effect of enhanced sludge washing on individual tank sludges as well as for groups of sludges that may be representative of different waste types. Spreadsheet results include the estimated mass and percentage of each element that would be removed with washing and leaching. Furthermore, estimated compositions are given of the final wash and leach streams and residual solids, in terms of both concentration and dry weight percent

  9. Little Puerco Wash-Catalpa Canyon Floodplain Management Study

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — The City of Gallup requested the Soil Conservation Service, through the McKinley Soil and Water Conservation District, to conduct a study of the Little Puerco Wash...

  10. Hand Washing: Do's and Dont's

    Science.gov (United States)

    ... hands frequently can help limit the transfer of bacteria, viruses and other microbes. Always wash your hands before: Preparing food or eating Treating wounds or caring for a sick person Inserting or removing contact lenses Always wash your hands after: Preparing food Using ...

  11. Automatic washing of hooves can help control digital dermatitis in dairy cows

    DEFF Research Database (Denmark)

    Thomsen, Peter Thorup; Kjær Ersbøll, Annette; Sørensen, Jan Tind

    2012-01-01

    washed with a water and 0.4% soap solution. In experiment 2, hooves were washed with water only. In each experiment, DD was scored in a hoof-trimming chute approximately 60 d after the start of hoof washing. Data were analyzed using a generalized linear mixed model. The outcome was the DD status of each....... In experiment 2, the odds ratio of having DD was 1.27 in the control leg compared with the washed leg. We concluded that automatic washing of hooves with water and soap can help decrease the prevalence of DD in commercial dairy herds....

  12. Renovating animal facilities to withstand disasters.

    Science.gov (United States)

    Cartwright, Jim; Contratto, Jim; Gould, Nathan; Freeman, William

    2013-10-01

    In the aftermath of Superstorm Sandy, new attention has been drawn to planning for and mitigating the effects of disasters on laboratory animal facilities. A number of design approaches and solutions can be easily incorporated into a new vivarium, enhancing its ability to withstand and recover from a disaster. Renovating a vivarium poses special challenges, however. Existing conditions in the project area may dictate which approaches or solutions are feasible, and retrofitting is often more complex and expensive than incorporating the same features into new construction. The authors explain how project design teams can evaluate the types of disasters that a renovated facility will need to address and develop a design strategy that responds to these disasters in the most effective way.

  13. Efficacy of 1.5% Dish Washing Solution and 95% Lemon Water in Substituting Perilous Xylene as a Deparaffinizing Agent for Routine H and E Staining Procedure: A Short Study

    Directory of Open Access Journals (Sweden)

    Anuradha Ananthaneni

    2014-01-01

    Full Text Available Aim. To assess the efficacy of dish washing solution and diluted lemon water in deparaffinizing sections during conventional hematoxylin and eosin staining technique. Objective. The objective is to utilize eco-friendly economical substitute for xylene. Materials and Methods. Using twenty paraffin embedded tissue blocks, three sections each were prepared. One section was stained with conventional H and E method (Group A and the other two sections with xylene-free (XF H and E (Groups B and C. Staining characteristics were compared with xylene and scoring was given. Total score of 3–5 was regarded as adequate for diagnosis and less than that inadequate for diagnosis. Statistical Analysis. Chi-square test, Kruskal Wallis ANOVA test, and Mann-Whitney U test were used. Results. Adequacy of nuclear staining, crispness, and staining for diagnosis were greater in both Groups A and C (100% than Group B (95%. Adequacy of cytoplasmic staining was similar in all the three groups (100%. Group B showed comparatively superior uniform staining and less retention of wax. Conclusion. Dish washing solution or diluted lemon water can be replaced for xylene as deparaffinizing agent in hematoxylin and eosin procedure.

  14. Negotiating heritage in Danish public housing renovation

    DEFF Research Database (Denmark)

    Martens Gudmand-Høyer, Sidse

    2017-01-01

    This paper presents a significant problem when it comes to the challenging task of safeguarding recent past architectural heritage with reference to the democratization ideals propagated by the New Heritage paradigm. Based on controversy mapping relating to the renovation of a Danish 1950s high...... and the performance of interventions conveying heritage understandings can be addressed and given a binding form for this process and its partners....

  15. Rebuilding instead of renovation?; Neubauen statt Sanieren?

    Energy Technology Data Exchange (ETDEWEB)

    Ott, W.; Seiler, B.; Kaufmann, Y. [Econcept AG, Zuerich (Switzerland); Binz, A.; Moosmann, A. [Fachhochschule beider Basel, Muttenz (Switzerland)

    2002-07-01

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of a study that examined the question of building renewal in Switzerland - should one rebuild or renovate? The report first examines the age-profile of Swiss buildings, defines renewal strategies and ideas, looks at renewal cycles and, in the light of future renewal demands, describes scenarios for replacement with new buildings instead of carrying out total renovations. The housing owners and their methods of management for multiple-apartment housing are described and the various factors involved in making decisions on how to renovate are discussed from the technical, legal and fiscal points of view. The report goes on to examine the ecological and energy aspects of renewal, presenting figures on energy consumption and material flows. Building renewal is also discussed from the social and regional planning points of view. The report is concluded with a discussion on rebuilding or renewal that takes current renewal deficits, costs and social aspects into account and makes recommendations for further action. An appendix presents renewal case studies.

  16. The Strategic-Renovation Banks’ Risks Management

    Directory of Open Access Journals (Sweden)

    Yeremeychuk Raisa A.

    2017-04-01

    Full Text Available The article is aimed at developing approaches to implementation of the strategic-renovation risk management. Essence of risk theories was researched, the concept of «risk» in the bank’s management system were analyzed. On the basis of a theoretical generalization of scientific literature and the carried out analysis of existing risk management strategies to ensure the security of banking business, the strategy of renovation management has been selected. Because bank risks are part of the economic risk system, they are complex in their nature. However, given the importance of bank risks, the interpretation of their essence is still a debating matter. In a certain number of cases, their essence is replaced by the cause of occurrence, that is, all the different circumstances, factors that lead to the losses. So today, banks are considering risks, in particular, not only as a source of possible losses, but also as an opportunity to generate additional profits. An algorithm for taking a strategic-renovation decision on the banks’ risks management system has been proposed.

  17. Washing water treatment process for UF{sub 6} cylinder by adjusting evaporation technology in a low temperature and low pressure

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki-tae; Ju, Young-jong; Cho, Nam-chan [KEPCO Nuclear Fuel Co., Daejeon (Korea, Republic of); Kim, Yun-kwan; Jin, Chang-suk [Jeontech CO., Suwon (Korea, Republic of)

    2016-10-15

    The liquid waste is treated in this procedure; 1) Add NaOH to the liquid waste and filter the mixture with a screen. 2) Screened residue is dried and then stored in a uranium storage. 3) liquid part is moved to a storage tank and radioactivity is measured in the liquid. 5) If the concentration of radioactivity is lower than corresponding regulation limit, the liquid moved to a reaction tank and evaporated with additional low concentration HF in 105℃. 6) Radioactivity of distillate is measured and the value is lower than regulation, it is treated with a thermal decomposition process and discharged to the atmosphere in gas state. 7) Solid waste produced in the evaporation step is managed as solid nuclear waste. The treatment procedure mentioned above has disadvantageous points, producing large amount of solid waste as well as, high energy and chemical consumption. In this study, liquid waste from a real scaled cylinder wash process is applied to evaporation system to confirm feasibility of the application of evaporation and, to reduce waste production and energy consumption. Liquid radioactive wastewater from a real scaled UF6 cylinder wash process was applied to evaporation treatment system. Radioactive concentration in gross alpha was removed 99.9% in the evaporation system. And the concentration in distillate was lower than the discharge regulation. Removal of U-235 was 99.9% in the process. And 15 other kinds of radionuclides in the raw wastewater were removed completely. Secondary waste production of the evaporation system is 15g/L.

  18. Apparatus for washing out halogens

    Energy Technology Data Exchange (ETDEWEB)

    Pier, M; Hahn, J; Kroenig, W

    1941-03-26

    An apparatus is described for washing out of halogens and the like or liquid halogen compounds from the products, which are formed on pressure hydrogenation or splitting of carbon-containing material in the presence of halogens or halogen compounds, consisting of a washing apparatus installed between the reaction vessel and the hot separator, which is inclined in relatively small space for steam regulation and contains, with the steam, arranged baffles, especially spirals.

  19. A wash fluid for drilling into a field

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, V M; Badzhurak, R F; Koptelova, Ye K; Rogovoy, V K; Sapozhnikov, N G

    1979-01-18

    A wash fluid is proposed, used in drilling wells in water and a content of 3-5% by weight starch products. To speed up destruction of the starch products, to the fluid are added amylolytic enzymes in the amount of 0.01-0.1 percent by weight of the starch products' weight. To lower the use of starch products, up to 3% clay can be added to the fluid. The wash fluid is prepared directly at the work site. Dry powder of modified starch is mixed with cold water until a colloidal solution is obtained. Such a wash fluid preserves the required structural-mechanical properties for 3-5 days, which ensures prompt drilling into the waterbearing layer and installation of the filter. Then, during the work process, 5-6 hours before the moment required for lowering the viscosity, to the wash fluid is added the amylolytic enzyme; under its influence, the starch molecules split up, and the viscosity drops sharply. Using this wash fluid enables a reduction in well construction times from the beginning of drilling to the end of development of the water-bearing layer, and a rise in outputs and well service lives by reducing sedimentation of the water-bearing formation and elimination of down times during work required while waiting for destruction of the starch wash fluid under natural conditions.

  20. Remediation of cadmium-contaminated paddy soils by washing with calcium chloride: Verification of on-site washing

    International Nuclear Information System (INIS)

    Makino, Tomoyuki; Kamiya, Takashi; Takano, Hiroyuki; Itou, Tadashi; Sekiya, Naoki; Sasaki, Kouta; Maejima, Yuji; Sugahara, Kazuo

    2007-01-01

    We developed a new, three-step soil-wash method to remediate Cd-contaminated paddy fields. The method comprises (1) chemically washing the field soil with a CaCl 2 solution; (2) washing the treated soil with water to eliminate residual Cd and CaCl 2 ; and (3) on-site treatment of wastewater using a portable wastewater treatment system. Cd concentrations in the treated water were below Japan's environmental quality standard (0.01 mg Cd L -1 ), and the removal of Cd from the exchangeable fraction was 55% and from the acid-soluble fraction 15%. While soil fertility properties were affected by the soil washing, adverse effects were not crucial and could be corrected. The washing had no affect on rice growth, and reduced the average Cd concentration in rice grains by about two-thirds compared to a control plot. These results confirmed the effectiveness of the soil-wash method in remediating Cd-contaminated paddy fields. - In situ soil washing in a paddy field using an on-site wastewater treatment system resulted in an effective decrease of Cd in soil and rice grains without affecting rice yield

  1. Leaching Behavior of Circulating Fluidised Bed MSWI Air Pollution Control Residue in Washing Process

    Directory of Open Access Journals (Sweden)

    Zhiliang Chen

    2016-09-01

    Full Text Available In this study, air pollution control (APC residue is conducted with water washing process to reduce its chloride content. A novel electrical conductivily (EC measurement method is proposed to monitor the dynamic change of chloride concentrations in leachate as well as the chloride content of the residue. The method equally applies to various washing processes with different washing time, liquid/solid ratio and washing frequency. The results show that washing effectively extracts chloride salts from APC residues, including those from circulating fluidized bed (CFB municipal solid waste incineration (MSWI. The most appropriate liquid/solid ratio and washing time in the first washing are found to be around 4 L water per kg of APC residue and 30 min, respectively, and washing twice is required to obtain maximum dissolution. The pH value is the major controlling factor of the heavy metals speciation in leachate, while chloride concentration also affects the speciation of Cd. Water washing causes no perceptible transfer of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs from the APC residue to leachate. The chloride concentration is strongly related with electrical conductivity (EC, as well as with the concentrations of calcium, sodium and potassium of washing water. Their regression analyses specify that soluble chloride salts and EC could act as an indirect indicator to monitor the change of chloride concentration and remaining chloride content, thus, contributing to the selection of the optimal washing conditions.

  2. Can washing-pretreatment eliminate the health risk of municipal solid waste incineration fly ash reuse?

    Science.gov (United States)

    Wang, Yao; Pan, Yun; Zhang, Lingen; Yue, Yang; Zhou, Jizhi; Xu, Yunfeng; Qian, Guangren

    2015-01-01

    Although the reuse of washing-pretreated MSWI fly ash bas been a hot topic, the associated risk is still an issue of great concern. The present study investigated the influence of washing-pretreatment on the total contents and bioaccessibility of heavy metals in MSWI fly ash. Furthermore, the study incorporated bioaccessibility adjustment into probabilistic risk assessment, to quantify the health risk from multi-pathway exposure to the concerned chemicals as a result of reusing washed MSWI fly ash. The results revealed that both water-washing and acid-washing process have resulted in the concentrated heavy metal content, and have reduced the bioaccessibility of heavy metals. Besides, the acid-washing process increased the cancer risk in most cases, while the effect of water-washing process was uncertain. However, both water-washing and acid-washing pretreatment could decrease the hazard index based on bioaccesilbility. Despite the uncertainties accompanying these procedures, the results indicated that, in this application scenario, only water-washing or acid-washing process cannot reduce the actual risk from all samples to acceptable level, especially for cancer risk. Copyright © 2014. Published by Elsevier Inc.

  3. Roof renovation of buildings 128 and 129

    CERN Multimedia

    2015-01-01

    The roof renovation of buildings 128 and 129 is scheduled to take place from 17 August to 15 October 2015.   During this period, access to the "raw material" workshop will be limited and controlled due to asbestos removal. Collecting your orders directly from the building will be difficult, or even impossible, and urgent requests will be difficult to carry out. We therefore ask you to create your requests via EDH, so that delivery may be carried out as soon as possible. Thank you for your understanding. GS Department

  4. Effects of vinasse accumulation ponds and decantation reservoirs of water used for washing cane sugar in water resources in Dobrada municipality, Sao Paulo State, Brazil; Efeitos da estocagem de vinhaca e das aguas de lavagem da cana-de-acucar na qualidade dos recursos hidricos da regiao de Dobrada, Sao Paulo

    Energy Technology Data Exchange (ETDEWEB)

    Sabadia, Jose Antonio Beltrao; Reboucas, Aldo da Cunha [Sao Paulo Univ., SP (Brazil). Inst. de Geociencias

    1996-12-31

    This work shows the results of a monitoring carried out in an area of about 21 km{sup 2}, Dobrada Municipality, central west region of the state of Sao Paulo (Brazil), where the impacts in ground water and surface water were evaluated by the infiltration and percolation of vinasse and water used for washing cane sugar, through accumulation ponds and decantation reservoirs, respectively, in areas of Bauru Aquifer (Cretaceous). The Bauru Aquifer, free and porous, occurs in a extended area of 104.000 km{sup 2} in Sao Paulo State, as a major exploitable aquifer (more than 15.000 wells), used for domestic and industrial water supplies. For the groundwater, the following measures were found in analyses exceeding drinking water standards (WHO; CONAMA/Brazil and Sao Paulo State): manganese (0,03 to 3,5 mg/l), iron (0.45 to 34 mg/l), aluminum (1 to 52 mg/l) and phosphate (0,03 to 0.38 mg/l). For superficial water, the following measures exceeded drinking water standards: total iron (3 mg/l) and phosphate (0,035 mg/l). The main purpose of this research is to improve the field methodology to characterize the impacts of vinasse and washing water of cane sugar infiltration/percolation., detaching the relationship between ground and surface water, with the major aim to supply the legislation to protect drinking water resources. (author) 11 refs.

  5. Cold or hot wash: Technological choices, cultural change, and their impact on clothes-washing energy use in China

    International Nuclear Information System (INIS)

    Lin, Jiang; Iyer, Maithili

    2007-01-01

    Usage pattern of clothes washing (and clothes washers) are strongly related to local cultural practices. Such practices have led to the development of distinctive clothes-washing technologies in the US, Europe, and Japan. In emerging markets such as China, several types of technologies often co-exist. Some use less energy but more water (the impeller type), and some use more energy but less water (the horizontal axis type). The competition between different technologies is thought to lead to better consumer choices. However, it could also lead to changes in clothes-washing habits-from cold to hot wash, and therefore to much higher energy use. This paper examines the standard development process in China to illustrate that adoption of foreign technologies and technical standards, if not carefully calibrated to the local cultural practices, could have unintended consequences for energy use and environment

  6. Extensions and renovations of reactor protection systems

    International Nuclear Information System (INIS)

    Hellmerichs, K.

    1985-01-01

    Increase of requirements by the authorities as to the design of reactor protection systems affected in the last years not only plans being under construction, but also resulted in partly spacious extensions and renovations. While working on the extensions and renovations a lot of problems arose: far-reaching performance of newest guidelines and rules in spite of old plant concepts; partly higher degree of redundancy requirements of the new systems in contrast to the present systems; use of present safeguard systems for new accident countermeasures; designation of priorities between present and new functions, especially in view of fault behaviour of present systems; adaptation of the new I and C equipment to the present signalisation-, operation- and information-arrangements under consideration of the present operational philosophy; spatial incorporation of new equipments; construction as to time without expanding of the planned refuelling phases. Because the KWU has planned and constructed such alterations in nearly 10 plants a lot of experience has been gathered. (author)

  7. Zero energy office building renovation; Energieneutrale kantoorrenovatie

    Energy Technology Data Exchange (ETDEWEB)

    Deguelle, D.; Krijnen, M. [DHV, Amersfoort (Netherlands); Heijnis, J. [cepezed, Delft (Netherlands)

    2011-04-15

    Building Brains has been set up by TNO as a cooperative and started September 21, 2009. The aim of the project was to answer the question how the energy consumption in the Netherlands can be reduced by 50% up to 2030 or how the built environment can be made energy-neutral. This issue of the magazine is dedicated to Building Brains project. Four different renovation concepts are compared: energy-neutral renovation that involves the exclusive use of sustainable generated energy;.the application of the passive construction principles; the use of Double Skin Facades; and decentralized facade-integrated installation techniques. Following the results of this study two optimized refurbishment approaches for a zero energy office are designed. [Dutch] Building Brains is een door TNO opgezet samenwerkingsproject dat op 21 september 2009 van start ging. Het doel van het project is antwoord te geven op de vraag hoe tot 2030 het energiegebruik in Nederland kan worden gehalveerd of hoe de gebouwde omgeving energieneutraal kan worden gemaakt. Deze aflevering van het tijdschrift TVVL is vrijwel geheel gewijd aan het Building Brains project. Er is onderzocht hoe verschillende renovatieconcepten scoren. Er zijn vier renovatieconcepten met elkaar vergeleken: energie neutraal renoveren door middel van duurzame energieopwekking, toepassen van het passiefhuisprincipe, toepassen van een tweedehuidfacade en toepassen van een decentrale, gevel-geintegreerde installatie. Uit de studie kwamen twee geoptimaliseerde concepten voor een energieneutrale kantoorrenovatie naar voren.

  8. Enhanced sludge washing evaluation plan

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, R.D.

    1994-09-01

    The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced sludge washing. Section 4.0 briefly discusses the potential important of policy issues to the evaluation. Section 5.0 discusses the methodology to be used in the evaluation process. Section 6.0 summarizes the milestones that have been defined to complete the enhanced sludge washing evaluation and provides a summary schedule to evaluate the performance of enhanced sludge washing. References are identified in Section 7.0, and additional schedule and milestone information is provided in the appendices.

  9. Enhanced sludge washing evaluation plan

    International Nuclear Information System (INIS)

    Jensen, R.D.

    1994-09-01

    The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced sludge washing. Section 4.0 briefly discusses the potential important of policy issues to the evaluation. Section 5.0 discusses the methodology to be used in the evaluation process. Section 6.0 summarizes the milestones that have been defined to complete the enhanced sludge washing evaluation and provides a summary schedule to evaluate the performance of enhanced sludge washing. References are identified in Section 7.0, and additional schedule and milestone information is provided in the appendices

  10. Prestart-up hydrogen peroxide solution washing of NPP unit with the RBMK-type reactor

    International Nuclear Information System (INIS)

    Gruzdev, N.I.; Man'kina, N.N.; Al'tshuller, M.A.

    1979-01-01

    Presented are the results of industrial hydrogen peroxide solution washing of condensating-feed system conducted on the second unit of the Kursk NPP. Duration of the washing constituted 8 hours. The hydrogen peroxide concentration during first 4 hours was 10-20 mg/kg at a flow rate of 260 m 2 /h, during the following 4 hours it constituted 2-5 mg/kg at a flow rate of 1000 m 3 /h. It is found out that prestart-up hydrogen peroxide washing of NPP power units with the RBMK-type reactor permits: to simplify essentially the technology and scheme of washing process; to reduce a flow rate of desalt washing water; to except environmental contamination with washing solutions and reagents being neutralized; to reduce the time of washing process; to reduce the time necessary for the achievement of reference water condition factors, and to increase the unit reliability and to improve a radiation situation

  11. Renovation and uprating of seven hydropower plants in Java

    International Nuclear Information System (INIS)

    Nuessli, W.

    1991-01-01

    The Indonesian Power Authority is planning to renovate and uprate seven hydropower stations in Java to expand plant life expectancy, ensure operating safety and reliability, and increase power and generation within economical limits. The power plants were constructed in the early 1920s and extended between 1945 and 1950. Their capacities vary between 4 and 20 MW. For the renovation project, Colenco Power Consulting Ltd. is acting as a consultant to PLN. In February 1990, Colenco inspected all seven power plants. The results of the inspections served as the basis for the development of renovation plans for each of the seven hydropower plants. To determine the cost of the proposed renovation plans, appraisers had to determine a method for comparing the value of an existing plant to that of a renovated one. The two different evaluation methods used for these comparisons are the focus of this paper

  12. Existing sustainable renovation concepts for single-family houses

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Vanhoutteghem, Lies; Svendsen, Svend

    2010-01-01

    In the Nordic Innovation Centre Project, SuccessFamilies, the main objective is to change the business environment in order to speed up the implementation of sustainable renovation of single-family houses – proposing new service concepts that will combine both the technical solutions, financing...... with individual solutions, traditional warehouses ”do-it-yourself-shops” and some actors marketing single products. To speed up the implementation of sustainable renovation of single-family houses there is a great need for full-service packages. Existing technical renovation concepts, typically focusing...... services as well as other promoting issues to overcome the behavioural, organizational, legal and social barriers that exist in sustainable renovation. A starting point for such a change has been to get an overview of the existing sustainable renovation concepts, i.e. full-service concepts and technical...

  13. Indoor Air Quality of Residential Building Before and After Renovation

    Science.gov (United States)

    Sánka, Imrich; Földváry, Veronika

    2017-06-01

    This study investigates the impact of energy renovation on the indoor air quality of an apartment building during the heating season. The study was performed in one residential building before and after its renovation. An evaluation of the indoor air quality was performed using objective measurements and a subjective survey. The concentration of CO2 was measured in the bedrooms, and a sampling of the total volatile compounds (TVOC) was performed in the living rooms of the selected apartments. Higher concentrations of CO2 and TVOC were observed in the residential building after its renovation. The concentrations of CO2, and TVOC in some of the cases exceeded the recommended maximum limits, especially after implementing energy-saving measures on the building. The average air exchange rate was visibly higher before the renovation of the building. The current study indicates that large-scale renovations may reduce the quality of an indoor environment in many apartments, especially in the winter season.

  14. Final Environmental Assessment to Renovate Fourth Cliff Recreational Area at Hanscom Air Force Base, Massachusetts

    Science.gov (United States)

    2014-11-17

    Renovate Fourth Cliff Recreational Annex Grading and topography changes may be necessary to design an appropriate drainage system at the site...goals: 1) Increase safety for personnel and patrons at the site; 2) Provide protection of the exposed cliff face from rainwater runoff; 3) Provide...be followed. Drainage design must meet Massachusetts Stormwater Management Standards, as well as comply with the Federal Clean Water Act. Solid

  15. 75 FR 39524 - Lead-Based Paint Renovation, Repair and Painting, and Pre-Renovation Education Activities in...

    Science.gov (United States)

    2010-07-09

    ..., Repair and Painting, and Pre- Renovation Education Activities in Target Housing and Child Occupied... pre-renovation education program in accordance with section 406(b) of TSCA, 15 U.S.C. 2686(b). This... and child-occupied facilities in the State of Oregon. Individuals and firms falling under the North...

  16. Laboratory testing in-tank sludge washing, summary letter report

    International Nuclear Information System (INIS)

    Norton, M.V.; Torres-Ayala, F.

    1994-09-01

    In-tank washing is being considered as a means of pretreating high-level radioactive waste sludges, such as neutralized current acid waste (NCAW) sludge. For this process, the contents of the tank will be allowed to settle, and the supernatant solution will be decanted and removed. A dilute sodium hydroxide/sodium nitrite wash solution will be added to the settled sludge and the tank contents will be mixed with a mixer pump system to facilitate washing of the sludge. After thorough mixing, the mixer pumps will be shut off and the solids will be allowed to re-settle. After settling, the supernatant solution will be withdrawn from the tank, and the wash cycle will be repeated several times with fresh wash solution. Core sample data of double shell tank 241-AZ-101 indicate that settling of NCAW solids may be very slow. A complicating factor is that strong thermal currents are expected to be generated from heat produced by radionuclides in the sludge layer at the bottom of the tank. Additionally, there are concerns that during the settling period (i.e., while mixing pumps and air-lift re-circulators are shut off), the radionuclides may heat the residual interstitial water in the sludge to the extent that violent steam discharges (steam bumping) could occur. Finally, there are concerns that during the washing steps sludge settling may be hindered as a result of the reduced ionic strength of the wash solution. To overcome the postulated reduced settling rates during the second and third washing steps, the use of flocculants is being considered. To address the above concerns and uncertainties associated with in-tank washing, PNL has conducted laboratory testing with simulant tank waste to investigate settling rates, steam bump potential, and the need for and use of flocculating agents

  17. Ground water contamination with (238)U, (234)U, (235)U, (226)Ra and (210)Pb from past uranium mining: cove wash, Arizona.

    Science.gov (United States)

    Dias da Cunha, Kenya Moore; Henderson, Helenes; Thomson, Bruce M; Hecht, Adam A

    2014-06-01

    The objectives of the study are to present a critical review of the (238)U, (234)U, (235)U, (226)Ra and (210)Pb levels in water samples from the EPA studies (U.S. EPA in Abandoned uranium mines and the Navajo Nation: Red Valley chapter screening assessment report. Region 9 Superfund Program, San Francisco, 2004, Abandoned uranium mines and the Navajo Nation: Northern aum region screening assessment report. Region 9 Superfund Program, San Francisco, 2006, Health and environmental impacts of uranium contamination, 5-year plan. Region 9 Superfund Program, San Franciso, 2008) and the dose assessment for the population due to ingestion of water containing (238)U and (234)U. The water quality data were taken from Sect. "Data analysis" of the published report, titled Abandoned Uranium Mines Project Arizona, New Mexico, Utah-Navajo Lands 1994-2000, Project Atlas. Total uranium concentration was above the maximum concentration level for drinking water (7.410-1 Bq/L) in 19 % of the water samples, while (238)U and (234)U concentrations were above in 14 and 17 % of the water samples, respectively. (226)Ra and (210)Pb concentrations in water samples were in the range of 3.7 × 10(-1) to 5.55 × 102 Bq/L and 1.11 to 4.33 × 102 Bq/L, respectively. For only two samples, the (226)Ra concentrations exceeded the MCL for total Ra for drinking water (0.185 Bq/L). However, the (210)Pb/(226)Ra ratios varied from 0.11 to 47.00, and ratios above 1.00 were observed in 71 % of the samples. Secular equilibrium of the natural uranium series was not observed in the data record for most of the water samples. Moreover, the (235)U/(total)U mass ratios ranged from 0.06 to 5.9 %, and the natural mass ratio of (235)U to (total)U (0.72 %) was observed in only 16 % of the water samples, ratios above or below the natural ratio could not be explained based on data reported by U.S. EPA. In addition, statistical evaluations showed no correlations among the distribution of the radionuclide concentrations

  18. Analysis and Monitoring of Energy Consumption and Indoor Climate in a School Before and After Deep Energy Renovation

    DEFF Research Database (Denmark)

    Rose, Jørgen; Thomsen, Kirsten Engelund; Bergsøe, Niels Christian

    2015-01-01

    kindergartens/institutions -- that will undergo deep energy renovation over the next fewyears.The seven buildings are being energy-renovated and monitored with support from the European Union- CONCERTO initiative as part of the project titled Cost-Effective Low-Energy Advanced Sustainable Solutions -- Class1...... ventilation systems with heat recovery, low-energy lighting, water-saving measures, improved insulation of piping, and improved control using building energy management systems. This paper presents preliminary results of the analysis and monitoring of energy consumption and indoor climate in one public school...

  19. Hand washing with soap and water together with behavioural recommendations prevents infections in common work environment: an open cluster-randomized trial.

    Science.gov (United States)

    Savolainen-Kopra, Carita; Haapakoski, Jaason; Peltola, Piia A; Ziegler, Thedi; Korpela, Terttu; Anttila, Pirjo; Amiryousefi, Ali; Huovinen, Pentti; Huvinen, Markku; Noronen, Heikki; Riikkala, Pia; Roivainen, Merja; Ruutu, Petri; Teirilä, Juha; Vartiainen, Erkki; Hovi, Tapani

    2012-01-16

    Hand hygiene is considered as an important means of infection control. We explored whether guided hand hygiene together with transmission-limiting behaviour reduces infection episodes and lost days of work in a common work environment in an open cluster-randomized 3-arm intervention trial. A total of 21 clusters (683 persons) were randomized to implement hand hygiene with soap and water (257 persons), with alcohol-based hand rub (202 persons), or to serve as a control (224 persons). Participants in both intervention arms also received standardized instructions on how to limit the transmission of infections. The intervention period (16 months) included the emergence of the 2009 influenza pandemic and the subsequent national hand hygiene campaign influencing also the control arm. In the total follow-up period there was a 6.7% reduction of infection episodes in the soap-and water arm (p = 0.04). Before the onset of the anti-pandemic campaign, a statistically significant (p = 0.002) difference in the mean occurrence of infection episodes was observed between the control (6.0 per year) and the soap-and-water arm (5.0 per year) but not between the control and the alcohol-rub arm (5.6 per year). Neither intervention had a decreasing effect on absence from work. We conclude that intensified hand hygiene using water and soap together with behavioural recommendations can reduce the occurrence of self-reported acute illnesses in common work environment. Surprisingly, the occurrence of reported sick leaves also increased in the soap-and water-arm. ClinicalTrials.gov: NCT00981877 The Finnish Work Environment Fund and the National Institute for Health and Welfare.

  20. Hand washing with soap and water together with behavioural recommendations prevents infections in common work environment: an open cluster-randomized trial

    Directory of Open Access Journals (Sweden)

    Savolainen-Kopra Carita

    2012-01-01

    Full Text Available Abstract Background Hand hygiene is considered as an important means of infection control. We explored whether guided hand hygiene together with transmission-limiting behaviour reduces infection episodes and lost days of work in a common work environment in an open cluster-randomized 3-arm intervention trial. Methods A total of 21 clusters (683 persons were randomized to implement hand hygiene with soap and water (257 persons, with alcohol-based hand rub (202 persons, or to serve as a control (224 persons. Participants in both intervention arms also received standardized instructions on how to limit the transmission of infections. The intervention period (16 months included the emergence of the 2009 influenza pandemic and the subsequent national hand hygiene campaign influencing also the control arm. Results In the total follow-up period there was a 6.7% reduction of infection episodes in the soap-and water arm (p = 0.04. Before the onset of the anti-pandemic campaign, a statistically significant (p = 0.002 difference in the mean occurrence of infection episodes was observed between the control (6.0 per year and the soap-and-water arm (5.0 per year but not between the control and the alcohol-rub arm (5.6 per year. Neither intervention had a decreasing effect on absence from work. Conclusions We conclude that intensified hand hygiene using water and soap together with behavioural recommendations can reduce the occurrence of self-reported acute illnesses in common work environment. Surprisingly, the occurrence of reported sick leaves also increased in the soap-and water-arm. Trial Registration ClinicalTrials.gov: NCT00981877 Source of funding The Finnish Work Environment Fund and the National Institute for Health and Welfare.

  1. Tips for cleanroom construction and renovation.

    Science.gov (United States)

    Mixon, William; Huffman, Lanny

    2009-01-01

    The installation or renovation of a cleanroom is an increasing priority among compounders who, to offer sterile preparations, must comply with the most recent version of United States Pharmacopeia revised General Chapter 797 guidelines. To upgrade their pharmacy facilites, many compounders have worked successfully with a large-scale mechanical engineering firm or a specialized construction company dedicated to cleanroom installation. However, a qualified local mechanical contractor with design capability is a valuable and often overlooked resource for the construction of customized stae-of-the-art cleanrooms. In this report, we describe the installation of such a facility in a busy pharmacy and suggest ways in which compounding pharmacists can identify competent local contractors and control the cost of construction and upgrades. The addition of a cleanroom has enabled The Compounding Pharmacy in Hickory, North Carolina, to achieve accreditation from the Pharmacy Compounding Accreditation Board.

  2. Acoustic Properties of a Renovated Building

    Directory of Open Access Journals (Sweden)

    Tomas Januševičius

    2011-02-01

    Full Text Available The article explores the effects of partitions, ceilings and facades on noise insulation in the renovated different buildings. The conducted experiments were aimed at analyzing partitions of 120 mm brick mounted gypsum panels while other walls were 520 mm thick and plastered on both sides. Under natural conditions, sound insulation factors of facades were measured and compared according to comfort classes. The obtained results revealed that thick brick walls of 520 mm insulated the sound of 58 decibels (dB (class B. In contrast, 120 mm brick masonry partition reduced sound only to 48 dB which is class E and agrees with the lowest class of sound insulation. We also calculated the sound insulation factor applying three formulas considering the mass law of sound insulation and comparing it with other previous studies. The paper examines and discusses the findings of the performed calculations and measurements.Article in Lithuanian

  3. Status report on the GANIL renovation program

    International Nuclear Information System (INIS)

    Loyer, F.

    1995-01-01

    Three years ago, a renovation program was initiated to ensure GANIL a lifetime of at least 15 years in order to allow an efficient use of the two radioactive ion beam facilities, SISSI which has been operational since last year and SPIRAL which will be in use in 98. The status of this program is reported which mainly concerns the control system, the RF systems (voltage and phase control devices), the vacuum system (control and pumping devices), the power supplies (interfaces, current sensors, and internal electronics), the beam instrumentation (electronics and local control devices) and the system which survey the accelerator access. The improvements of the accelerator ECR sources are also described and the first results to produce refractor metallic ion beams like uranium are mentioned. (author)

  4. Abdominopelvic washings: A comprehensive review

    Directory of Open Access Journals (Sweden)

    Erika F Rodriguez

    2013-01-01

    Full Text Available Intraperitoneal spread may occur with gynecological epithelial neoplasms, as well as with non-gynecological malignancies, which may result in serosal involvement with or without concomitant effusion. Therefore, washings in patients with abdominopelvic tumors represent important specimens for cytologic examination. They are primarily utilized for staging ovarian cancers, although their role has decreased in staging of endometrial and cervical carcinoma. Abdominopelvic washings can be positive in a variety of pathologic conditions, including benign conditions, borderline neoplastic tumors, locally invasive tumors, or distant metastases. In a subset of cases, washings can be diagnostically challenging due to the presence of co-existing benign cells (e.g., mesothelial hyperplasia, endosalpingiosis, or endometriosis, lesions in which there is only minimal atypia (e.g., serous borderline tumors or scant atypical cells, and the rarity of specific tumor types (e.g., mesothelioma. Ancillary studies including immunocytochemistry and fluorescence in situ hybridization may be required in difficult cases to resolve the diagnosis. This article provides a comprehensive and contemporary review of abdominopelvic washings in the evaluation of gynecologic and non-gynecologic tumors, including primary peritoneal and mesothelial entities.

  5. Successful sustainable renovation; Succesvolle duurzame renovatie

    Energy Technology Data Exchange (ETDEWEB)

    Van Doorn, A.Q.C.M.; De Ruyter, G.M. [Yacht, Randstad, Diemen (Netherlands); Kaper, A.A. [Ballast Nedam, Nieuwegein (Netherlands)

    2011-04-15

    Building Brains has been set up by TNO as a cooperative and started September 21, 2009. The aim of the project was to answer the question how the energy consumption in the Netherlands can be reduced by 50% up to 2030 or how the built environment can be made energy-neutral. This issue of the magazine is dedicated to Building Brains project. It is often said that Smart defined ambitions and strict process management are important ingredients for successful realization of building projects. Sustainable real estate developments can be considered as highly ambitious projects. To find out how and why sustainable renovation projects actually became sustainable, a group of professionals systematically evaluated 21 leading Dutch real estate renovation projects. For each project they interviewed the client, consultant, architect and contractor. Based on the results it was concluded that a pre-defined (sustainability) ambition is not a necessity to realize a project that can be considered sustainable in practice. [Dutch] Building Brains is een door TNO opgezet samenwerkingsproject dat op 21 september 2009 van start ging. Het doel van het project is antwoord te geven op de vraag hoe tot 2030 het energiegebruik in Nederland kan worden gehalveerd of hoe de gebouwde omgeving energieneutraal kan worden gemaakt. Deze aflevering van het tijdschrift TVVL is vrijwel geheel gewijd aan het Building Brains project. Een jaar lang zijn de succes- en faalfactoren van duurzame renovatieprojecten onderzocht. Voor 21 projecten zijn in totaal 73 actoren geinterviewd. Er werd een vragenlijst gebruikt, die vanuit vijf invalshoeken was opgesteld: ambitiestelling, duurzame maatregelen, actoren, beleidsomgeving en proces. Per project zijn opdrachtgevers, architecten, aannemers, adviseurs en gebruikers geinterviewd. Alle data is verwerkt in een database. De projecten voldoen aan het selectiecriterium Trias Energetica. Het accent lag op woningbouw, waar de grootste uitdaging ligt voor duurzame

  6. Effects of water quality, sanitation, handwashing, and nutritional interventions on child development in rural Kenya (WASH Benefits Kenya): a cluster-randomised controlled trial.

    Science.gov (United States)

    Stewart, Christine P; Kariger, Patricia; Fernald, Lia; Pickering, Amy J; Arnold, Charles D; Arnold, Benjamin F; Hubbard, Alan E; Dentz, Holly N; Lin, Audrie; Meerkerk, Theodora J; Milner, Erin; Swarthout, Jenna; Colford, John M; Null, Clair

    2018-04-01

    Poor nutrition and infectious diseases can prevent children from reaching their developmental potential. We aimed to assess the effects of improvements in water, sanitation, handwashing, and nutrition on early child development in rural Kenya. In this cluster-randomised controlled trial, we enrolled pregnant women in their second or third trimester from three counties (Kakamega, Bungoma, and Vihiga) in Kenya's western region, with an average of 12 households per cluster. Groups of nine geographically adjacent clusters were block-randomised, using a random number generator, into the six intervention groups (including monthly visits to promote target behaviours), a passive control group (no visits), or a double-sized active control group (monthly household visits to measure child mid-upper arm circumference). The six intervention groups were: chlorinated drinking water; improved sanitation; handwashing with soap; combined water, sanitation, and handwashing; improved nutrition through counselling and provision of lipid-based nutrient supplements; and combined water, sanitation, handwashing, and nutrition. Here we report on the prespecified secondary child development outcomes: gross motor milestone achievement assessed with the WHO module at year 1, and communication, gross motor, personal social, and combined scores measured by the Extended Ages and Stages Questionnaire (EASQ) at year 2. Masking of participants was not possible, but data assessors were masked. Analyses were by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01704105. Between Nov 27, 2012, and May 21, 2014, 8246 women residing in 702 clusters were enrolled. No clusters were lost to follow-up, but 2212 households with 2279 children were lost to follow-up by year 2. 5791 (69%) children were measured at year 1 and 6107 (73%) at year 2. At year 1, compared with the active control group, the combined water, sanitation, handwashing, and nutrition group had greater rates of

  7. Axial Dispersion during Hanford Saltcake Washing

    International Nuclear Information System (INIS)

    Josephson, Gary B.; Geeting, John GH; Lessor, Delbert L.; Barton, William B.

    2006-01-01

    Clean up of Hanford salt cake wastes begins with dissolution retrieval of the sodium rich salts that make up the dominant majority of mass in the tanks. Water moving through the porous salt cake dissolves the soluble components and also displaces the soluble radionuclides (e.g. 137Cs and 99TcO4- ). The separation that occurs from this displacement, known as Selective dissolution, is an important component in Hanford?s pretreatment of low activity wastes for subsequent Supplemental treatment. This paper describes lab scale testing conducted to evaluate Selective dissolution of cesium from non-radioactive Hanford tank 241-S-112 salt cake simulant containing the primary chemicals found the actual tank. An modified axial dispersion model with increasing axial dispersion was developed to predict cesium removal. The model recognizes that water dissolves the salt cake during washing, which causes an increase in the axial dispersion during the wash. This model was subsequently compared with on-line cesium measurements from the retrieval of tank 241-S-112. The model had remarkably good agreement with both the lab scale and full scale data

  8. Wastewater renovation using constructed soil filter (CSF): a novel approach.

    Science.gov (United States)

    Nemade, P D; Kadam, A M; Shankar, H S

    2009-10-30

    Constructed soil filter (CSF) also known as Soil Biotechnology (SBT) is a process for water renovation which makes use of formulated media with culture of soil macro- and microorganisms. CSF combines sedimentation, infiltration and biodegradation processes to remove oxidizable organics and inorganics of wastewater in a single facility. Operating experience shows hydraulic loading in the range of 0.05-0.25 m(3)/m(2) h and organic loading up to 200-680 g/m(2) d. The results show increase in dissolved oxygen levels, COD removal (from 352 mg/l to 20 mg/l); BOD removal (from 211 mg/l to 7.0 mg/l); suspended solids removal (from 293 mg/l to 16 mg/l); turbidity reduction (from 145 NTU to 5.3 NTU); iron (from 5 mg/l to 0.3 mg/l); arsenic (from 500 microg/l to 10 microg/l); total coliform and fecal coliform removal (from 145 x 10(5) to 55 CFU/100 mL and 150 x 10(8) to 110 CFU/100 mL respectively), with desired pathogen levels as per WHO standards, i.e. aeration and no odor, fish compatible water quality and evergreen ambience.

  9. Socioeconomic Renovation in Viet Nam: The Origin, Evolution, and ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Referred to as doi moi, this "renovation" has produced dramatic changes in ... In this book, Vietnamese scholars describe the origins and impacts of these changes. ... for two Colombian cities were discussed at ADAPTO's second international ...

  10. Prerequisites for Successful Strategic Partnerships for Sustainable Building Renovation

    DEFF Research Database (Denmark)

    Jensen, Per Anker; Johansen, Jakob Berg; Thuesen, Christian

    The purpose of this paper is to identify the prerequisites for establishing successful strategic partnerships in relation to renovating buildings sustainably. Establishing strategic partnerships is in the paper seen as a potential way to make building renovation more sustainable in Denmark...... and analysis of strategic partnerships models as well as typical processes used in building renovation. Experiences from development of new strategic partnerships have particularly been found in the UK and Sweden. Based on two workshops with practitioners representing the whole value chain in the construction...... industry and analyses of two exemplary cases the paper suggests prerequisites for establishing successful strategic partnerships for sustainable building renovation. The results show that strategic partnerships are collaborations set up between two or more organizations that remain independent...

  11. Success and fail factors in sustainable real estate renovation projects

    NARCIS (Netherlands)

    Volker, L.

    2011-01-01

    Sustainability remains an important issue for the construction industry. Yet, sustainable real estate developments are still considered as highly ambitious projects. To find out how and why sustainable renovation projects actually became sustainable we systematically evaluated 21 leading Dutch real

  12. ECO-TECHNIQUE OF SEWER RENOVATION USING COMPOSITE ...

    African Journals Online (AJOL)

    2011-12-31

    Dec 31, 2011 ... An eco-technical renovation of the sewage system is developed in this paper; this ... structural analysis of a typical shell unit with an ovoid form .... described by five fundamental equations, can be reduced to three equations.

  13. Environmental diagnosis of the washing machine motor

    DEFF Research Database (Denmark)

    Erichsen, Hanne K. Linnet

    1997-01-01

    An environmental diagnosis of the washing machine focusing on the motor is performed. The goal of the diagnosis is to designate environmental focus points in the product. The LCA of the washing machine showed impact potentials from the life cycle of the product (see: LCA of a washing machine). Th...... up 2%, Manually disassembling and recycling of metals, Reuse of motor in a new washing machine, aluminium wire instead of copper wire in the motor....

  14. Techno-economic analysis of energy renovation measures for a district heated multi-family house

    International Nuclear Information System (INIS)

    Gustafsson, Marcus; Gustafsson, Moa Swing; Myhren, Jonn Are; Bales, Chris; Holmberg, Sture

    2016-01-01

    Highlights: • Energy saving measures can be cost-effective as part of a planned renovation. • Primary energy consumption, non-renewable energy consumption and CO_2 emissions are assessed for different electricity mixes. • EAHP can be a cost-effective and environmentally beneficial complement to district heating. • EAHP has lower LCC and significantly shorter payback time than ventilation with heat recovery. • Low-temperature ventilation radiators improve the COP of the heat pump. - Abstract: Renovation of existing buildings is important in the work toward increased energy efficiency and reduced environmental impact. The present paper treats energy renovation measures for a Swedish district heated multi-family house, evaluated through dynamic simulation. Insulation of roof and façade, better insulating windows and flow-reducing water taps, in combination with different HVAC systems for recovery of heat from exhaust air, were assessed in terms of life cycle cost, discounted payback period, primary energy consumption, CO_2 emissions and non-renewable energy consumption. The HVAC systems were based on the existing district heating substation and included mechanical ventilation with heat recovery and different configurations of exhaust air heat pump. Compared to a renovation without energy saving measures, the combination of new windows, insulation, flow-reducing taps and an exhaust air a heat pump gave up to 24% lower life cycle cost. Adding insulation on roof and façade, the primary energy consumption was reduced by up to 58%, CO_2 emissions up to 65% and non-renewable energy consumption up to 56%. Ventilation with heat recovery also reduced the environmental impact but was not economically profitable in the studied cases. With a margin perspective on electricity consumption, the environmental impact of installing heat pumps or air heat recovery in district heated houses is increased. Low-temperature heating improved the seasonal performance factor of the

  15. A framework for sustainability science: a renovated IPAT identity.

    Science.gov (United States)

    Waggoner, P E; Ausubel, J H

    2002-06-11

    Learning actors' leverage for change along the journey to sustainability requires quantifying the component forces of environmental impact and integrating them. Population, income, consumers' behavior, and producers' efficiency jointly force impact. Here, we renovate the "IPAT Identity" to identify actors with the forces. Forcing impact I are P for population, A for income as gross domestic product (GDP) per capita, C for intensity of use as a good per GDP, and T for efficiency ratios as impact per good. In the "ImPACT Identity," parents modify P, workers modify A, consumers modify C, and producers modify T. Because annual percentage changes in component forces add to a change in national impact, actors' leverage is reflected transparently in consistent units of annual percentage changes that can be compared from force to force. Examples from energy and food, farming and manufacturing, and steel and water show that declining C, called dematerialization, can temper the sustainability challenge of growth (P x A), and that innovation or efficient technology that lowers T can counter rising consumption (P x A x C). Income elasticity can accommodate connections between income and other forces. From rates of change of forces, the identity can forecast impacts. Alternatively, by identifying the necessary change in forces to cause a projected impact, ImPACT can assay the likelihood and practicability of environmental targets and timetables. An annual 2-3% progress in consumption and technology over many decades and sectors provides a benchmark for sustainability.

  16. 40 CFR 745.92 - Fees for the accreditation of renovation and dust sampling technician training and the...

    Science.gov (United States)

    2010-07-01

    ... renovation and dust sampling technician training and the certification of renovation firms. 745.92 Section... Renovation § 745.92 Fees for the accreditation of renovation and dust sampling technician training and the... the following disciplines: Renovator, dust sampling technician. (ii) Exemption. No fee shall be...

  17. ETAP-ERN project: assessment of drinking water treatment by nano filtration powered by renewable energy; Proyecto ETAP-ERN: evaluacion del tratamiento del agua potable mediante energia renovable y nanofiltracion

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Ramirez, J. A.; Garcia-Vaquero Marin, N.

    2009-07-01

    ETAP-ERN project is mainly to evaluate the potential of nano filtration to complement or replace, if necessary drinking water conventional treatment, in order to obtain higher drinking water quality and sanitary guarantee at a minimum cost. The use of photovoltaic and wind energy power systems does this plant to be unique worldwide. The pilot plant, 50 m{sup 3}/day capacity, has two subunits: energy power (60 kWh) and water production. It will be located at the drinking water treatment plant of El Montanes, Puerto Real (Cadiz, Spain). (Author)

  18. Hand washing practices amongst medical students in Port Harcourt ...

    African Journals Online (AJOL)

    Alasia Datonye

    Background: Hand washing with soap and water is one of ... Method: This was a descriptive cross sectional survey ... simple questionnaire exploring perceptions, attitudes and ... Many studies have shown that doctors decontaminating their hands between seeing patients ..... countries: a systematic review and meta analysis.

  19. Effectiveness Of Different House-Hold Hand Washing Agents On ...

    African Journals Online (AJOL)

    Hand hygiene is a very important procedure in infection control. Washing agents commonly in use were investigated for their effectiveness in reducing hand floral and cotton towel was used as drying agent. Agents studied include; water alone, carex soap, dettol, and imperial leather. The hands were inoculated (deliberate ...

  20. The building stock from perspective of change - renovation roadmap

    Energy Technology Data Exchange (ETDEWEB)

    Airaksinen, M., Email: miimu.airaksinen@vtt.fi

    2012-06-15

    By 2050, population, society and economic structures will have changed several times. The long and short-term goals and objectives concerning our built environment are mutually contradictory. Determining objectives or creating scenarios for the future built environment is fruitless. We should approach the development of the built environment from the perspective of change and improve the flexibility and adaptability of the built environment. For the users, a built environment meeting their basic needs is part of sustainable development. Identified short-range renovation needs include eliminating damp and mould problems, improving energy and eco-efficiency, removing obstacles to mobility and adapting buildings to accommodate the needs of the elderly. Vacated areas and buildings should be recycled and offered a new life supporting a sense of community and service production. Improved energy efficiency reduces greenhouse gas emissions. Instead of renovating individual buildings, renovation of the entire area is recommended. Sustainability in construction translates into favouring recycling and renewable materials and building-specific energy systems using renewable and/or low-emission resources. It is recommended that renovations to improve energy efficiency are scheduled to coincide with other maintenance/ renovations so as to reduce costs. In renovation construction, the role of service improvement is more important than products. Improved services help to identify a solution that fulfils several customer needs, meets financial limitations and can be implemented efficiently. Companies are advised to view renovation construction as an innovative market segment entitled to its own service portfolio. Truths about new building should be discarded and new services developed based on recent study results and new technologies. (orig.)

  1. Concrete slurry, wash and loss water mitigation.

    Science.gov (United States)

    2012-08-01

    This report presents an evaluation of wastewaters derived from concrete placement and maintenance and the : preparation of best management practices (BMPs). Investigation and documentation of existing practices was done : to ensure application to rea...

  2. Coagulation-flocculation process applied to wastewaters generated in hydrocarbon-contaminated soil washing

    International Nuclear Information System (INIS)

    Torres, L. g.; Belloc, C.; Iturbe, R.; Bandala, E.

    2009-01-01

    A wastewater produced in the contaminated soil washing was treated by means of coagulation-flocculation (CF) process. the wastewater treatment in this work continued petroleum hydrocarbons, a surfactant, i. e., sodium dodecyl sulphate (SDS) as well as salts, humic acids and other constituents that were lixiviated rom the soil during the washing process. The aim of this work was to develop a process for treating the wastewaters generated when washing hydrocarbon-contaminated soils in such a way that it could be recycled to the washing process, and at the end of the cleaning up, the waters could be disposed properly. (Author)

  3. Computer Simulation of Bound Component Washing To Minimize Processing Costs

    Directory of Open Access Journals (Sweden)

    Dagmar Janáčová

    2011-11-01

    Full Text Available In this paper we focused on the optimization of the washing processes because many technological processes are characterizedby large consumption of water, electrical energy and auxiliary chemicals mainly. For this reason it is very important to deal withthem. For the optimization of process of washing it is possible to set up an access of the indirect modeling that is based on make-up ofmathematical models coming out of study of the physical operation mechanism. The process is diffusion character it is characterizedby the value of diffusion effective coefficient and so called structure power of the removing item to the solid phase. The mentionedparameters belong to input data that are appropriate for the automatic control of washing process.

  4. Dry washing: the solution for contaminated liquid effluent releases

    International Nuclear Information System (INIS)

    L'homme, D.; Trambouze, P.

    1998-01-01

    The release of wash water used for contaminated garments poses an ever-increasing problem on nuclear sites. Even though the radioactivity is low, it mixes with organic compounds, thus polluting a large quantity of liquid effluents. In many cases, several thousands of m 3 /year per nuclear site are produced, which at times represents more than 30% of the volume of total releases. The conventional dry cleaning process is not a viable option, given that repeated washing cause clothes to fade and the odors are rot removed completely. In order to eliminate releases, STMI has developed, after several years of research with the Technological University of Compiegne, France, a solvent dry washing process for garments used in the nuclear industry. (author)

  5. Treatment of car wash wastewater by UF membranes

    Science.gov (United States)

    Istirokhatun, Titik; Destianti, Puti; Hargianintya, Adenira; Oktiawan, Wiharyanto; Susanto, Heru

    2015-12-01

    The existence of car wash service facilitates car owners to remove dirt and grime from their vehicles. However, the dirt washed off vehicles as well as the cleaning materials themselves may be harmful to the environment if they are not properly managed and discharged. Many technologies have been proposed to treat car wash wastewater such as coagulation flocculation, tricking filter and flocculation-flotation. Nevertheless, these technologies have low efficiency to eliminate oil and small organic compounds. Ultrafiltration (UF) membranes were used in this study to treat car wash wastewater. This study investigated the performance of UF membranes under various pressures to remove COD, oil and grease, and also turbidity from car wash waste water. The membrane performance was examined by investigation of permeate flux and membrane rejection. The results meet the standard of environmental regulation and it is possible to be reused. The highest rejection was shown by PES10 (polyethersulfone 10 kDa) in 1 bar operation with complete rejection for both turbidity and oil and grace and 95% rejection for COD.

  6. A novel washing algorithm for underarm stain removal

    Science.gov (United States)

    Acikgoz Tufan, H.; Gocek, I.; Sahin, U. K.; Erdem, I.

    2017-10-01

    After contacting with human sweat which comprise around 27% sebum, anti-perspirants comprising aluminium chloride or its compounds form a jel-like structure whose solubility in water is very poor. In daily use, this jel-like structure closes sweat pores and hinders wetting of skin by sweat. However, when in contact with garments, they form yellowish stains at the underarm of the garments. These stains are very hard to remove with regular machine washing. In this study, first of all, we focused on understanding and simulating such stain formation on the garments. Two alternative procedures are offered to form jel-like structures. On both procedures, commercially available spray or deo-stick type anti-perspirants, standard acidic and basic sweat solutions and artificial sebum are used to form jel-like structures, and they are applied on fabric in order to get hard stains. Secondly, after simulation of the stain on the fabric, we put our efforts on developing a washing algorithm specifically designed for removal of underarm stains. Eight alternative washing algorithms are offered with varying washing temperature, amounts of detergent, and pre-stain removal procedures. Better algorithm is selected by comparison of Tristimulus Y values after washing.

  7. Environmental Impacts Of Zirab Coal Washing Plant, Mazandaran, Iran

    Science.gov (United States)

    Moore, F.; Esmaeili, A.

    2009-04-01

    Extraction and beneficiation operations associated with coal mining increase the rate of chemical reaction of waste material to air and water media. Zirab coal washing plant is located on the bank of the Cherat stream in Mazandaran province, Iran. coal Mined from central Alborz coalfield mines is not suitable for use in Iranian Steel Corporation. Hence, coal ash content is reduced by physical and chemical processes in this plant. These processes leave a large quantity of liquid and solid wastes that accumulate in waste dump and tailing dam. sediment and water samples taken from Sheshrudbar and Cherat streams and also from Talar river show high concentration of Cd, Mo and As in water samples of coal washing plant and the associated drainage. Eh-pH diagrams revealed the chemical species of elements in water. The enrichment factor and geoaccumulation index show that Cd, Hg, Mo and V are enriched in bottom sediments of the coal washing plant and decrease with increasing distance from the plant. Sequential extraction analysis Results of three sediment samples of Cherat stream show that silicate bound is the major phase in samples taken before and after the plant, but adjacent to the plant, organic bound is dominant. The high concentration of Cd and Mo in the water soluble phase, is noticeable and may result in high mobility and bioavailability of these elements. Mann-Whitney and Wilcoxon tests on six samples, before and after the coal washing plant support the obtained results. Keywords: Zirab; coal washing plant; Sequential extraction analysis; Mann-whitney; Wilcoxon; Enrichment factor; Geoaccumulation index.

  8. Evaluation of Resuspension from Propeller Wash in DoD Harbors

    Science.gov (United States)

    2016-05-01

    in ERDC’s Prop-Wash Tank Resuspension by propeller wash from tugboat: in-situ field data: near-bed velocity field, shear stress, critical shear...samples of sediment and water were collected prior to any resuspension event. A C14 Tractor and a slightly smaller Tiger tug boats were used in San

  9. Actual heating energy savings in thermally renovated Dutch dwellings

    International Nuclear Information System (INIS)

    Majcen, Daša; Itard, Laure; Visscher, Henk

    2016-01-01

    The register of the Dutch social housing stock was analysed, containing 300.000 dwellings, renovated between 2010 and 2013. The main objective was twofold: to evaluate the performance gap in these dwellings before and after the renovation and to establish what renovation measures achieve the highest reduction of consumption, particularly in practice (actual savings). The results showed large performance gaps in dwellings with low R and high U values, local heating systems, changes from a non-condensing into a condensing boiler and upgrades to a natural ventilation system. Regarding the actual effectiveness of renovation measures, replacement of old gas boilers with more efficient ones yields the highest energy reduction, followed by deep improvements of windows. Installing mechanical ventilation yields a small reduction compared to other measures, but still much larger than theoretically expected. The paper shows once more that the calculation method currently in use cannot be considered accurate if compared to actual consumption. The study demonstrated that unrealistic theoretical efficiencies of heating systems and insulation values are causing a part of the performance gap. Nowadays, large datasets of buildings thermal performance and actual consumption offer an opportunity to improve these misconceptions. - Highlights: • Performance gap is lower in more efficient buildings. • Replacements of gas boilers – the most energy reduction among renovation measures. • Replacing the ventilation system yields a much larger reduction than expected. • How well are the standard values of the calculation methods defined? • Provide large public building performance databases including actual use data.

  10. Evaluation of airborne particulates and fungi during hospital renovation.

    Science.gov (United States)

    Overberger, P A; Wadowsky, R M; Schaper, M M

    1995-07-01

    This study was conducted over 30 weeks on a hospital floor undergoing partial renovation. Some patients housed on the floor were immunosuppressed, including bone marrow transplant recipients. The construction zone was placed under negative pressure and was separated from patient rooms by existing hospital walls and via erection of a temporary barrier. Other control measures minimized patient exposure to airborne materials. Air sampling was done for 3 weeks prior to construction, 24 weeks during construction, and 3 weeks after renovation was completed. Airborne particulate concentrations, total spore counts, particle size, and fungal species were assessed. At the beginning of the renovation there were increases in airborne particulates (from 0.2 to 2.0 mg/m3) and fungal spores (from 3.5 to 350 colony forming units (CFU/m3), but only in the construction zone. Throughout the remainder of the renovation, particulate and fungal spore levels fluctuated inside the construction zone but remained close to baseline values in the patient area. When renovation was completed, particulates and spore counts inside the construction zone decreased to preconstruction levels. The primary fungus isolated from air samples was Penicillium. This study demonstrated that control measures were effective in reducing exposures of hospitalized patients to airborne particulates and spores and in reducing the increased risk of aspergillosis and other fungal infections associated with hospital construction projects. The data from this study may be useful in establishing exposure guidelines for other health care settings.

  11. Energy renovation practices in Danish homes. The influence of energy labels on home renovation practices

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, Toke Haunstrup; Gram-Hanssen, Kirsten [Danish Building Research Institute, Aalborg University, Dr. Neergaards Vej 15, DK-2970 Hoersholm (Denmark); Adjei, Afi [Building Research Establishment Ltd. BRE, Bucknalls Lane, Garston, WD25 9XX Watford (United Kingdom); De Best-Waldhober, Marjolein [Energy research Centre of the Netherlands ECN, Policy Studies, Amsterdam (Netherlands)

    2012-02-15

    Heating of dwellings represents a major policy challenge for the transition to a low carbon society. In Denmark, heating of dwellings represents about 25% of the total Danish final energy consumption and about 13% of the total CO2 emission. The majority of this is related to heating of older dwellings, and as the rate of replacement is low, the main potential for energy saving is to improve the energy efficiency of the existing dwelling stock through energy renovation. This paper provides an analysis of Danish experiences with energy labels (also known as the Energy Performance Certificate, EPC), which indicate the energy efficiency of buildings and include recommendations for improvements. The aim of the EPC is to motivate homeowners to do energy improvements. In Denmark, energy audit schemes date back to the early 1980s and energy rating of houses (energy labelling) was introduced in 1997. The long history of energy audit schemes and energy labelling makes Denmark an interesting case for the study of the experiences with and impact of this kind of policy measure. With the EU Energy Performance of Buildings Directive (EPBD) from 2002, an energy labelling scheme similar to the Danish scheme introduced in 1997 is now in use in all EU member states. The focus of this paper is on the homeowners' experience and use of the EPC and the key research questions are: How do the homeowners understand and use the EPC? Does the EPC have an influence on home energy renovation practices? The analysis is based on results from a survey of Danish homeowners who have purchased a home with an EPC within recent years. The Danish survey is part of the European project IDEAL EPBD, which was funded by the European Commission under the Intelligent Energy Europe programme and run from 2008 to 2011. The results indicate a rather limited influence of the EPC on Danish homeowners' home energy renovation practices. Also, the results show that even though most homeowners find the label

  12. The Renovation and Future Capabilities of the Thacher Observatory

    Science.gov (United States)

    O'Neill, Katie; Osuna, Natalie; Edwards, Nick; Klink, Douglas; Swift, Jonathan; Vyhnal, Chris; Meyer, Kurt

    2016-01-01

    The Thacher School is in the process of renovating the campus observatory with a new meter class telescope and full automation capabilities for the purpose of scientific research and education. New equipment on site has provided a preliminary site characterization including seeing and V-band sky brightness measurements. These data, along with commissioning data from the MINERVA project (which uses comparable hardware) are used to estimate the capabilities of the observatory once renovation is complete. Our V-band limiting magnitude is expected to be better than 21.3 for a one minute integration time, and we estimate that milli-magnitude precision photometry will be possible for a V=14.5 point source over approximately 5 min timescales. The quick response, autonomous operation, and multi-band photometric capabilities of the renovated observatory will make it a powerful follow-up science facility for exoplanets, eclipsing binaries, near-Earth objects, stellar variability, and supernovae.

  13. Energy Renovation of Danish Single-Family Houses

    DEFF Research Database (Denmark)

    Mortensen, Andrea

    2015-01-01

    . The results show that despite the barriers the owners can in fact be motivated to perform private energy renovations. A sound project economy is all-important for this to happen and it should if possible be supported by improvements in both comfort, indoor environment and architecture to increase......The PhD project is based on requirements from the European Union to reduce the energy consumption and on current renovation needs of and a huge energy saving potential in the Danish single-family houses from the 1960’s and 1970’s. The project focuses on the barriers for energy renovations...... of these houses and on defining motivation factors for the homeowners. The barriers are many and variating in influence and studies show that both professionals and homeowners are affected. The barriers range from lack of interest and knowledge to uncertainties about among others economy and technical solutions...

  14. Prerequisites for Successful Strategic Partnerships for Sustainable Building Renovation

    DEFF Research Database (Denmark)

    Jensen, Per Anker; Johansen, Jakob Berg; Thuesen, Christian

    2017-01-01

    The purpose of this paper is to identify the prerequisites for establishing successful strategic partnerships in relation to renovating buildings sustainably. Establishing strategic partnerships is in the paper seen as a potential way to make building renovation more sustainable in Denmark...... industry and analyses of two exemplary cases the paper suggests prerequisites for establishing successful strategic partnerships for sustainable building renovation. The results show that strategic partnerships are collaborations set up between two or more organizations that remain independent...... particularly in terms of reducing energy consumption and use of resources and increase productivity. However, until now we have only had a limited number of such partnerships implemented and the few examples that do exist, mostly concern the construction of new buildings. The paper is based on an investigation...

  15. Detecting wash trade in the financial market

    OpenAIRE

    Cao, Yi; Li, Yuhua; Coleman, Sonya; Belatreche, Ammar; McGinnity, T. M.

    2014-01-01

    Wash trade refers to the activities of traders who utilise deliberately designed collusive transactions to increase the trading volumes for creating active market impression. Wash trade can be damaging to the proper functioning and integrity of capital markets. Existing work focuses on collusive clique detections based on certain assumptions of trading behaviours. Effective approaches for analysing and detecting wash trade in a real-life market have yet to be developed. T...

  16. 40 CFR 745.90 - Renovator certification and dust sampling technician certification.

    Science.gov (United States)

    2010-07-01

    ... sampling technician certification. 745.90 Section 745.90 Protection of Environment ENVIRONMENTAL PROTECTION... technician certification. (a) Renovator certification and dust sampling technician certification. (1) To become a certified renovator or certified dust sampling technician, an individual must successfully...

  17. Development of Facilities Master Plan and Laboratory Renovation Project

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Andrea D

    2011-10-03

    Funding from this grant has allowed Morehouse School of Medicine to complete its first professionally developed, comprehensive campus master plan that is in alignment with the recently completed strategic plan. In addition to master planning activities, funds were used for programming and designing research renovations, and also to supplement other research facility upgrades by providing lighting and equipment. The activities funded by this grant will provide the catalyst for substantial improvement in the School's overall facilities for biomedical education and research, and will also provide much of the information needed to conduct a successful campaign to raise funds for proposed buildings and renovations.

  18. The CABRI fast neutron Hodoscope: Renovation, qualification program and first results following the experimental reactor restart

    Science.gov (United States)

    Chevalier, V.; Mirotta, S.; Guillot, J.; Biard, B.

    2018-01-01

    The CABRI experimental pulse reactor, located at the Cadarache nuclear research center, southern France, is devoted to the study of Reactivity Initiated Accidents (RIA). For the purpose of the CABRI International Program (CIP), managed and funded by IRSN, in the framework of an OECD/NEA agreement, a huge renovation of the facility has been conducted since 2003. The Cabri Water Loop was then installed to ensure prototypical Pressurized Water Reactor (PWR) conditions for testing irradiated fuel rods. The hodoscope installed in the CABRI reactor is a unique online fuel motion monitoring system, operated by IRSN and dedicated to the measurement of the fast neutrons emitted by the tested rod during the power pulse. It is one of the distinctive features of the CABRI reactor facility, which is operated by CEA. The system is able to determine the fuel motion, if any, with a time resolution of 1 ms and a spatial resolution of 3 mm. The hodoscope equipment has been upgraded as well during the CABRI facility renovation. This paper presents the main outcomes achieved with the hodoscope since October 2015, date of the first criticality of the CABRI reactor in its new Cabri Water Loop configuration. Results obtained during reactor commissioning phase functioning, either in steady-state mode (at low and high power, up to 23 MW) or in transient mode (start-up, possibly beyond 20 GW), are discussed.

  19. Lowell Observatory's 24-inch Clark Refractor: Its History and Renovation

    Science.gov (United States)

    Schindler, Kevin; Nye, Ralph; Rosenthal, Peter

    2016-01-01

    In 1895, Percival Lowell hired eminent telescope maker Alvan G. Clark to build a 24-inch refractor. Lowell intended the telescope intitally for observing Mars in support of his controversial theories about life on that planet. Clark finished the telescope within a year and at a cost of $20,000. Lowell and his staff of assistants and astronomers began observing through it on July 23, 1896, setting off a long and productive career for the telescope.While Lowell's Mars studies dominated early work with the Clark, V.M. Slipher by the 1910s was using it to observe planetary rotations and atmospheric compositions. He soon revolutionized spectroscopic studies, gathering excruciatingly long spectra - some in excess of 40 hours - of the so-called white nebula and determining startling radial velocities, evidence of an expanding universe. In the 1960s, scientists and artists teamed up on the Clark and created detailed lunar maps in support of the Apollo program.In recent decades, the Clark has played a central role in the education programs at Lowell, with general public audiences, students, and private groups all taking advantage of this unique resource.With this nearly 120 years of contant use, the Clark had been wearing down in recent years. The telescope was becoming more difficult to move, old electrical wiring in the dome was a fire hazard, and many of the telescope's parts needed to be repaired or replaced.In 2013, Lowell Observatory began a fundraising campaign, collecting $291,000 to cover the cost of dome and telescope renovation. Workers removed the entire telescope mount and tube assembly from the dome, examining every part from tube sections to individuals screws. They also stabilized the dome, adding a water vapor barrier and new outer wall while reinforcing the upper dome. The project lasted from January, 2014 through August, 2015. The facility reopened for daytime tours in September, 2015 and evening viewing the following month.

  20. Carbon balance of renovated grasslands: input- or output-driven?

    Science.gov (United States)

    Choncubhair, Órlaith Ní; Osborne, Bruce; Lanigan, Gary

    2015-04-01

    Temperate grasslands constitute over 30% of the Earth's naturally-occurring biomes and make an important contribution towards the partial mitigation of anthropogenic greenhouse gas emissions by terrestrial ecosystems. In permanent temperate grasslands, biomass production and sward quality can deteriorate over time and periodic renovation activities, involving soil tillage and reseeding, are commonly carried out to halt this decline. Long-term cultivation of agricultural land has been associated with soil aggregate degradation and reduced soil carbon storage. However, the impact of these single tillage disturbances on C cycling in grasslands is less clear. This study evaluated gaseous and dissolved organic carbon (DOC) losses following a single tillage event by subjecting grassland lysimeters with contrasting soil drainage characteristics to simulated conventional inversion or minimum tillage. Field-scale CO2 emissions after conventional tillage were also quantified and empirically modelled over short- and medium-term timeframes to delineate the ecosystem response to environmental variables. Soil moisture was the limiting determinant of ecosystem carbon release following conventional tillage. Freshly-tilled soils were associated with reduced water retention and increased sensitivity to soil moisture, which was particularly pronounced following rewetting events. Significantly elevated but ephemeral CO2 effluxes were detected in the hours following inversion ploughing, however tillage disturbance did not generate significantly enhanced C emission rates in the medium term. Equally, DOC losses were not significantly amplified by conventional tillage compared with conservative minimum tillage and were predominantly controlled by soil drainage across tillage regimes. Our results suggest that a net ecosystem source of 120 to 210 g C m-2 over an approximately two-month period was most likely a consequence of reduced productivity and C input rather than enhanced soil CO2

  1. Early stage decision support for sustainable building renovation – A review

    DEFF Research Database (Denmark)

    Nielsen, Anne Nørkjær; Jensen, Rasmus Lund; Larsen, Tine Steen

    2016-01-01

    Decision support tools for building renovation are important as assistance to professional building owners when setting goals for sustainability, and for making sure that the objectives are met throughout the design process, both when renovating a single building or choosing renovation actions wi...

  2. 77 FR 74472 - Application to Export Electric Energy; Energia Renovable S.C., LLC

    Science.gov (United States)

    2012-12-14

    ... DEPARTMENT OF ENERGY [OE Docket No. EA-387] Application to Export Electric Energy; Energia... application. SUMMARY: Energia Renovable S.C., LLC (Energia Renovable) has applied for authority to transmit...)). On September 11, 2012, DOE received an application from Energia Renovable for authority to transmit...

  3. IEA SHC Task 37: advanced housing renovation - Final report; IEA SHC Task 37: advanced housing renovation - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Hastings, R.

    2010-01-15

    This final report for the Swiss Federal Office of Energy (SFOE) reports on work done within the framework of the International Energy Agency's Solar Heating and Cooling program. The project addressed the energy consumption of residential buildings and their renovation. The report discusses the goals set for the project and reports on five projects that were initiated. These include the refurbishment of apartment buildings to meet the 'Passive House' standard, air-tightness, potential for the use of solar energy, solar facades and the renovation of historic listed buildings. Conclusions resulting from these projects are presented and discussed.

  4. Soil washing and post-wash biological treatment of petroleum hydrocarbon contaminated soils

    OpenAIRE

    Bhandari, Alok

    1992-01-01

    A laboratory scale study was conducted to investigate the treatability of petroleum contaminated soils by soil washing and subsequent biological treatment of the different soil fractions. In addition to soils obtained from contaminated sites, studies were also performed on soils contaminated in the laboratory. Soil washing was performed using a bench-scale soil washing system. Washing was carried out with simultaneous fractionation of the bulk soil into sand, silt and clay fractions. Cl...

  5. EFRT M-12 Issue Resolution: Solids Washing

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, David L.; Schonewill, Philip P.; Toth, James J.; Huckaby, James L.; Eslinger, Paul W.; Hanson, Brady D.; Kurath, Dean E.; Minette, Michael J.

    2009-08-14

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.” The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. Two operating scenarios were evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-VSL-T01A/B ultrafiltration feed vessels, identified as Integrated Test A. The second scenario has caustic leaching conducted in the UFP-VSL-T02A ultrafiltration feed preparation vessel, identified as Integrated Test B. Washing operations in PEP Integrated Tests A and B were conducted successfully as per the approved run sheets. However, various minor instrumental problems occurred, and some of the process conditions specified in the run sheet were not met during the wash operations, such as filter-loop flow-rate targets not being met. Five analytes were selected based on full solubility and monitored in the post-caustic-leach wash as successful indicators of washing efficiency. These were aluminum, sulfate, nitrate, nitrite, and free hydroxide. Other analytes, including sodium, oxalate, phosphate, and total dissolved solids, showed indications of changing solubility; therefore, they were unsuitable for monitoring washing efficiency. In the post-oxidative-leach wash, two analytes with full solubility were selected as suitable indicators of washing

  6. Road surface washing system for decontaminating radioactive substances. Experiment of radioactive decontamination

    International Nuclear Information System (INIS)

    Endo, Mitsuru; Endo, Mai; Kakizaki, Takao

    2015-01-01

    The Great East Japan Earthquake that occurred on March 11, 2011 resulted in the explosion of the TEPCO Fukushima 1st Nuclear Power Plant and the global dispersion of a large quantity of radioactive substances. A high radiation dose was particularly recorded in Fukushima prefecture several weeks after the accident, although the level is presently sufficiently low. However, considering that the adverse effects of low but extended exposure to radiation are yet to be negated, there is the urgent need for further decontamination. In our study, we focused on the efficient decontamination of radioactive substances in residential areas, for which we propose a high-pressure water jet system for washing road surfaces. The system differs from conventional systems of its type that were initially designed for use in the immediate environment of the nuclear reactors of the TEPCO Fukushima 1st Nuclear Power Plant. The proposed system consists of multiple washing, transporter, and server robots. The washing robots decontaminate the road surface using high-pressure water jets and are transported between washed and unwashed areas by the transporter robots. The server robots supply the water used for washing and absorb the polluted water together with ground dust. In this paper, we describe the concept of the system and present the results of decontamination experiments. Particular attention is given to the washing robot and its mechanism and control method. The results of the integration of the washing robot in an experimental system confirmed the feasibility of the proposed system. (author)

  7. Optimal Portfolio Choice with Wash Sale Constraints

    DEFF Research Database (Denmark)

    Astrup Jensen, Bjarne; Marekwica, Marcel

    2011-01-01

    We analytically solve the portfolio choice problem in the presence of wash sale constraints in a two-period model with one risky asset. Our results show that wash sale constraints can heavily affect portfolio choice of investors with unrealized losses. The trading behavior of such investors...

  8. Renovating Interior Office Space: What a Manager Needs To Consider.

    Science.gov (United States)

    Babey, Evelyn R.

    When planning an office renovation, a manager should design an office layout that is efficient and should consider the psychological aspects of office design, including sound level, color harmony, and lighting. The manager must also have a good understanding of all phases of the project plan and the timing involved. There are basically five phases…

  9. Overheating risk barriers to energy renovations of single family houses

    DEFF Research Database (Denmark)

    Psomas, Theofanis Ch.; Heiselberg, Per Kvols; Duer, Karsten

    2016-01-01

    Highlights •Energy renovations of houses in moderate climates increase overheating risk. •Critical measures are the floor insulation and the improvement of the airtightness. •Decrease of the g value of windows diminishes the intensity and the period of it. •Static method of assessment shows highe...

  10. Post Occupancy Evaluation of 23 Newly Renovated Apartments in Copenhagen

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Afshari, Alireza

    2016-01-01

    The present article is based on the post occupancy occupants’ perception of indoor air quality of recently renovated 23 residential apartments in Copenhagen. The apartments are equipped with novel mechanical ventilation systems. The apartments can be categorised in four, according to the design o...

  11. Supply-side collaboration for energy-efficient renovations

    NARCIS (Netherlands)

    Straub, A.; Mlecnik, E.

    2015-01-01

    The supply side for nearly zero energy building (nZEB) renovation of owner-occupied single-family houses in Europe is suffering from a severe image problem of lack of knowledge and trust, inefficient construction processes, insufficient quality assurance and communication difficulties with

  12. Renovation techniques for fatigue cracked orthotropic steel bridge decks

    NARCIS (Netherlands)

    de Jong, F.B.P.

    2007-01-01

    This dissertation presents the research into renovation techniques for orthotropic steel bridge decks. These techniques are needed to solve fatigue problems in the decks of these bridges, as several fatigue cracks have been detected in the deck structure of these bridges the last decade. A

  13. Collaborative business model development for home energy renovations

    NARCIS (Netherlands)

    Mlecnik, E.; Straub, A.; Haavik, T

    2018-01-01

    In the EU, housing retrofit rates have to increase to about 2.5–3% of the housing stock per year to achieve policy goals. The development of new business models and collaboration of SMEs in a fragmented market is expected to result in an increase in home renovations. This study presents a way to

  14. Maturity model for strategic collaboration in sustainable building renovation

    DEFF Research Database (Denmark)

    Johansen, Jakob Berg; Jensen, Per Anker; Thuesen, Christian

    2017-01-01

    To enable the construction industry to execute sustainable renovation projects which entails a reduction in use of resources, an increase in productivity and a more socially sustainable construction process, new tools are needed. A maturity model can be a simple and effective tool for a company...

  15. Sustainable (Re)Construction : The Potential of the Renovation Market

    NARCIS (Netherlands)

    Usanov, A.; Chivot, E.

    2013-01-01

    The Sustainable Urban (Re)Construction Briefing argues that renovation is going to play an increasingly important role in the overall construction market – for several reasons. One of them is the urgency of climate change mitigation. Europe has a large stock of buildings, which together contribute

  16. Genesis Eco Systems, Inc. soil washing process

    International Nuclear Information System (INIS)

    Cena, R.J.

    1994-01-01

    The Genesis soil washing system is an integrated system of modular design allowing for maximum material handling capabilities, with optimized use of space for site mobility. The Surfactant Activated Bio-enhanced Remediation Equipment-Generation 1 (SABRE-1, Patent Applied For) modification was developed specifically for removing petroleum byproducts from contaminated soils. Scientifically formulated surfactants, introduced by high pressure spray nozzles, displace the contaminant from the surface of the soil particles into the process solution. Once the contaminant is dispersed into the liquid fraction of the process, it is either mechanically removed, chemically oxidized, or biologically oxidized. The contaminated process water is pumped through the Genesis Biosep (Patent Applied For) filtration system where the fines portion is flocculated, and the contaminant-rich liquid portion is combined with an activated mixture of nutrients and carefully selected bacteria to decompose the hydrocarbon fraction. The treated soil and dewatered fines are transferred to a bermed stockpile where bioremediation continues during drying. The process water is reclaimed, filtered, and recycled within the system

  17. Gas turbine cleaning upgrade (compressor wash)

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, P. [Gas Turbine Efficiency, Jarfalla (Sweden)

    1998-12-31

    The influence of gas turbine degradation on operating costs is high. Gas turbine cleaning is one of many actions taken for power recovery and is to consider as preventive maintenance. It is generally performed within the industrial field and occasionally within the aero sector. In order to meet the gas turbine development win high blade loads and ever-increasing temperatures, together with emission Aces and environmental regulations, more efficient and careful cleaning methods are needed. Following a survey about potentials for cost reduction in gas turbine operation a new man-hour and water saving cleaning method has been evaluated for a standard process. Compared with traditional cleaning methods, the new method is water,- cost,- weight and space saving due to a new washing technique. Traditional methods are based on using different nozzles for ON and OFF-line cleaning, which rise the demand for complicated systems. In the new method the same nozzle installation, same liquid flow and pressure is used for both ON and OFF-line cleaning. This gives a cost reduction of appr. 20.000 - 30.000 USD per gas turbine depending on installation and size. Evaluation of the new method shows significantly improved ON -line cleaning performance and thus OFF -line cleaning is required only during scheduled stops. (orig.) 10 refs.

  18. Gas turbine cleaning upgrade (compressor wash)

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, P [Gas Turbine Efficiency, Jarfalla (Sweden)

    1999-12-31

    The influence of gas turbine degradation on operating costs is high. Gas turbine cleaning is one of many actions taken for power recovery and is to consider as preventive maintenance. It is generally performed within the industrial field and occasionally within the aero sector. In order to meet the gas turbine development win high blade loads and ever-increasing temperatures, together with emission Aces and environmental regulations, more efficient and careful cleaning methods are needed. Following a survey about potentials for cost reduction in gas turbine operation a new man-hour and water saving cleaning method has been evaluated for a standard process. Compared with traditional cleaning methods, the new method is water,- cost,- weight and space saving due to a new washing technique. Traditional methods are based on using different nozzles for ON and OFF-line cleaning, which rise the demand for complicated systems. In the new method the same nozzle installation, same liquid flow and pressure is used for both ON and OFF-line cleaning. This gives a cost reduction of appr. 20.000 - 30.000 USD per gas turbine depending on installation and size. Evaluation of the new method shows significantly improved ON -line cleaning performance and thus OFF -line cleaning is required only during scheduled stops. (orig.) 10 refs.

  19. Contaminant resorption during soil washing

    International Nuclear Information System (INIS)

    Gombert, D.

    1993-01-01

    To evaluate the applicability of soil washing to a specific site requires some basic research in how contaminants are bound. Much can be learned from sequential extraction methodology based on micronutrient bioavailability studies wherein the soil matrix is chemically dissected to selectively remove particular fixation mechanisms independently. This procedure uses a series of progressively more aggressive solvents to dissolve the principle phases that make up a soil, however, the published studies do not appear to consider the potential for a contaminant released from one type of site to resorb on another site during an extraction. This physical model assumes no ion exchange or adsorption at sites either previously occupied by other ions, or exposed by the dissolution. Therefore, to make engineering use of the sequential extraction data, the release of contamination must be evaluated relative to the effects of resorption. Time release studies were conducted to determine the optimum duration for extraction to maximize complete destruction of the target matrix fraction while minimizing contaminant resorption. Tests with and without a potassium brine present to inhibit cesium resorption indicated extraction efficiency could be enhanced by as much as a factor of ten using the brine

  20. Effects of particle size on the morphology and waterand thermo-resistance of washed cottonseed meal-based wood adhesives

    Science.gov (United States)

    Water wash of cottonseed meal is more cost-efficient and environment-friendly than the protein isolation which involves alkaline extraction and acidic precipitation. Thus, water-washed cottonseed meal (WCSM) is more promising as biobased wood adhesives. In this work, we examined the effects of the p...

  1. WASH activities at two Ebola treatment units in Sierra Leone.

    Directory of Open Access Journals (Sweden)

    Michaela Mallow

    Full Text Available The 2014 outbreak of Ebola virus disease (EVD in West Africa was the largest in history. Starting in September 2014, International Medical Corps (IMC operated five Ebola treatment units (ETUs in Sierra Leone and Liberia. This paper explores how future infectious disease outbreak facilities in resource-limited settings can be planned, organized, and managed by analyzing data collected on water, sanitation, and hygiene (WASH and infection prevention control (IPC protocols.We conducted a retrospective cohort study by analyzing WASH/IPC activity data routinely recorded on paper forms or white boards at ETUs during the outbreak and later merged into a database from two IMC-run ETUs in Sierra Leone between December 2014 and December 2015.The IMC WASH/IPC database contains data from over 369 days. Our results highlight parameters key to designing and maintaining an ETU. High concentration chlorine solution usage was highly correlated with both daily patient occupancy and high-risk zone staff entries; low concentration chlorine usage was less well explained by these measures. There is high demand for laundering and disinfecting of personal protective equipment (PPE on a daily basis and approximately 1 (0-4 piece of PPE is damaged each day.Lack of standardization in the type and format of data collected at ETUs made constructing the WASH/IPC database difficult. However, the data presented here may help inform humanitarian response operations in future epidemics.

  2. Distillery spent wash: Treatment technologies and potential applications

    International Nuclear Information System (INIS)

    Mohana, Sarayu; Acharya, Bhavik K.; Madamwar, Datta

    2009-01-01

    Distillery spent wash is the unwanted residual liquid waste generated during alcohol production and pollution caused by it is one of the most critical environmental issue. Despite standards imposed on effluent quality, untreated or partially treated effluent very often finds access to watercourses. The distillery wastewater with its characteristic unpleasant odor poses a serious threat to the water quality in several regions around the globe. The ever-increasing generation of distillery spent wash on the one hand and stringent legislative regulations of its disposal on the other has stimulated the need for developing new technologies to process this effluent efficiently and economically. A number of clean up technologies have been put into practice and novel bioremediation approaches for treatment of distillery spent wash are being worked out. Potential microbial (anaerobic and aerobic) as well as physicochemical processes as feasible remediation technologies to combat environmental pollution are being explored. An emerging field in distillery waste management is exploiting its nutritive potential for production of various high value compounds. This review presents an overview of the pollution problems caused by distillery spent wash, the technologies employed globally for its treatment and its alternative use in various biotechnological sectors

  3. Soil and minespoil fill as media for renovation of nitrogen and phosphorus in domestic wastewater

    International Nuclear Information System (INIS)

    Peterson, C.E.; Reneau, R.B. Jr.; Hagedorn, C.

    1998-01-01

    Development of US Appalachian coal mining regions has been hampered by lack of domestic waste disposal technologies suited to fills. The suitability of on-site wastewater treatment and disposal systems (OSWTDS) in fill material is uncertain due to the effects of surface mining on soil physical properties. This research evaluated the potential for renovation of N and P present in domestic wastewater by fills from mining operations. N and P were chosen because of their potential adverse environmental impacts. Soil-fill (a mixture of Jefferson, fine-loamy, siliceous, mesic Typic Hapludult and Muskingom, fine-loamy, mixed, mesic Typic Dystrochrept soils) and minespoil (spoil)-fill (blasted rock material associated with the Taggart Marker and Low Splint Bench coal seams of the Upper Middle Wise Formation) were used. Septic tank effluent (STE) and sand filter effluent (SFE) were applied to spoil-fill columns at four loading rates and spoil-fill columns at one loading rate for a period of 20 wk. Renovation of wastewater was assessed by determining the concentration of N and P present in column leachate. Reduction of inorganic N(NO 3 - + NH 4 + ), based on N/Cl ratios ranged from 14.9 to 32.1% after the varying application rates of STE and SFE passed through the soil columns. However, leachate NO 3 - -N concentrations were still above the 10 mg -1 drinking water standard. The quantity of P emerging from the spoil-fill columns (3.0 mg PL -1 ) was higher than anticipated and may be related to the indigenous P present in the minespoil. Sorption of P in the spoil-fill column decreased with increased STE and SFE application (reduction ranged from 99.1 to 74.4%). Results from this study indicate that there is potential for renovating wastewater in OSWTDS in selected soil-fill areas in reclaimed minelands. 33 refs., 2 figs., 4 tabs

  4. Washing of Cloth Contaminated with Radionuclides Using a Detergent-free Laundry System

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Sung Paal

    2005-07-01

    In this study, a new laundry system to wash clothes without using detergent (detergent-free) was applied to wash clothes contaminated with radionuclides at the RWTF of KAERI. If the clothes contaminated with radionuclides and soil decontaminated and cleaned by washing without using detergent, the problem caused by the detergent could be solved naturally. The experiment was performed in two stages. In the first stage, washability of the processed water from the detergent=free laundry system was investigated with regard to its decontamination efficiency for the radionuclides and the detergency for the soil by using the test cloth specimens. In the second stage, real working clothes contaminated with radionuclides from the RWTF were washed by using a laundry machine equipped with a detergent-free system. Decontamination and detergency of the clothes were estimated after washing and the wastewater was also analyzed for its properties.

  5. Value based building renovation - A tool for decision-making and evaluation

    DEFF Research Database (Denmark)

    Jensen, Per Anker; Maslesa, Esmir

    2015-01-01

    Research on the barriers for building renovation in Denmark has revealed that an important obstacle is a lack of simple and holistic tools that can assist stakeholders in prioritisation and decision-making during the early stages of building renovation projects. The purpose of this article...... is to present a tool - RENO-EVALUE, which can be used as decision support for sustainable renovation projects, and for evaluation, during and after building renovations. The tool is a result from the European Eracobuild project ACES - "A concept for promotion of sustainable retrofitting and renovation in early...... stages". This article presents the main result of a work package concerning benefits of renovation. RENO-EVALUE has been developed from four case studies on renovation projects in Denmark, tested and validated on the cases and in a Delphi study. The tool is value based by focusing on the different...

  6. Assessment of Washing with Antioxidant on the Oxidative Stability of Fatty Fish Mince during Processing and Storage

    DEFF Research Database (Denmark)

    Eymard, Sylvie; Jacobsen, Charlotte; Baron, Caroline

    2010-01-01

    Fatty fish have been recognized as potential raw material for the production of surimi; however, they can easily oxidize. The ability of antioxidants added in the washing water to reduce oxidation during the washing and subsequent storage needs to be evaluated. Horse mackerel (Trachurus trachurus...... performed. Results indicated that the antioxidants were accumulated differently, but all antioxidants tested were able to prevent lipid oxidation in fatty fish mince during washing and subsequent storage. The ranking in terms of oxidative stability of the washed minces was CA = PG > SP > W. The antioxidants......) mince was washed three times with 3 volumes of cold water (W) or the antioxidant solutions caffeic acid (CA) or propyl gallate (PG), at concentrations of 100 mg/kg, or spermine (SP), at a concentration of 400 mg/kg. Accumulation of antioxidant in the mince at each washing step was evaluated...

  7. Late washing filter cleaning cycle demonstration

    International Nuclear Information System (INIS)

    Meyer, M.L.; McCabe, D.J.

    1992-01-01

    The DWPF Late Washing Facility will filter cesium and potassium tetraphenyl borate (TPB) solids using a Mott sintered metal filter, identical to the filter now used in the In-tank Precipitation Facility. The purpose of the late wash step is primarily to remove the nitrite salts from the slurry prior to delivery to DWPF. Periodic chemical cleaning of the filter will be required, presumably after each batch although the actual required frequency could not be determined on the lab-scale. Minimization of chemical cleaning solution volumes is key to maximizing the attainment of the Late Wash facility. This report summarizes work completed in experiments designed to identify minimum cleaning solution requirements

  8. Soil physical characteristics after EDTA washing and amendment with inorganic and organic additives

    International Nuclear Information System (INIS)

    Zupanc, Vesna; Kastelec, Damijana; Lestan, Domen; Grcman, Helena

    2014-01-01

    Soil washing has been established as suitable remediation technology, with most research focused on metal removing efficiency and toxic effect on plants, less on the influence on soil physical characteristics, which was the focus of this study. In soil column experiment highly contaminated soil and soil washed with EDTA, mixed with additives (gypsum, hydrogel, manure, peat) were tested. White clover was used as a soil cover. Yield, metal concentration in soil and plant, aggregate fractionation and stability, saturated hydraulic conductivity and soil water retention of the soil were measured. Soil washing decreased metal concentration in soil and plants, but yield of white clover on remediated soil was significantly lower compared to the original soil. Significant differences in water retention characteristics, aggregate fractionation and stability between original and remediated soil have been determined. Gypsum, hydrogel and peat increased plant available water, manure and peat increased yield on remediated soil. -- Highlights: • Clover yield on washed soil was significantly lower than on original soil. • Organic additives increased yield on remediated soils. • Soil washing changed soil water retention and soil structure. • Hydrogen, gypsum and peat increased plant available water of remediated soil. -- The study critically examines yield, plant metal uptake and possible changes in soil physical characteristics as a consequence of soil washing procedure for metal pollution remediation

  9. UO2 production process with methanol washing

    International Nuclear Information System (INIS)

    Sondermann, T.

    1978-01-01

    The invention refers to a process for the recovery of methanol used for washing the ammonium uranyl carbonate obtained during UO 2 production. The methanol contains about 50% H 2 O, about 10% (NH 4 ) 2 CO 3 , and is radioactive. According to the invention the methanol is purified at reduced pressure in a distillation unit and then led back to the washing unit. (UWI) 891 HP/UWI 892 MBE [de

  10. Energi- og miljøvurdering ved renovering

    DEFF Research Database (Denmark)

    Holleris Petersen, E.

    En afprøvning af pc-værktøjet BEAT 2000's viser, at BEAT 2000 er et velegnet værktøj, der umiddelbart kan anvendes til energi- og miljøvurdering af renoveringssager. BEAT 2000 er afprøvet dels på renovering med energibesparende foranstaltninger i form af solfangere, solvægge og ventilationsanlæg...... med varmegenvinding, dels på mere traditionel renovering af små, utidssvarende lejligheder. En udbygning af datagrundlaget, især for alternative energibesparende løsninger og de materialer, der indgår, vil kunne reducere tidsforbruget ved definition af de utraditionelle og usædvanlige bygningsdele...

  11. Renovation and Expansion of the Caspary Research Building. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Grassia, V. L.

    2004-02-07

    Critical to the Hospital's rebuilding efforts have been its public partners at the federal, state, and local government levels who have made a major financial commitment to renovating the Hospital's research infrastructure. To date, the Hospital for Special Surgery (HSS) has been awarded a total of nearly $8.5 million to create and equip new, state-of-the-art laboratories for scientific investigations. The modernization of the Hospital's research facilities was jump-started in 1998 with a $950,000 seed grant from the National Institutes of Health (NIH) to renovate laboratories for immunology research in the Caspary Research Building. Coupled with a matching $5.5 million commitment from HSS, this infusion of NIH funding laid the groundwork for an overhaul of all of the Hospital's research space.

  12. Sustainable renovation concepts for single-family houses

    DEFF Research Database (Denmark)

    Vanhoutteghem, Lies; Tommerup, Henrik M.; Svendsen, Svend

    , the financial possibilities of the homeowner etc. Calculation of packages of energy efficient renovation solutions targeted the three segments of houses show that primary energy use and heating bill can be reduced with up to about 75% or a factor 4 corresponding to the level of a new house or better. It seems...... that the passive house level can not quite be reached with standard solutions. They require that more ambitious measures are applied. The total investment needed to reduce the heating bill by a factor 4 including replacement of e.g. roof and windows is up to EUR 100,000. It is generally difficult to obtain...... be seen as a possibility to make it easy for the homeowner to comply with possible future requirements to realize far-reaching energy savings in connection with extensive renovations, provided that the building sector offers the solutions. Homeowners need someone to take care of all relevant steps...

  13. Analysis and Comparison of Overheating Indices in Energy Renovated Houses

    DEFF Research Database (Denmark)

    Psomas, Theofanis Ch.; Heiselberg, Per Kvols; Duer, Karsten

    2015-01-01

    The scientific literature offers a number of methods for assessing the likelihood of overheating in buildings. The paper calculates eight well-documented indices for four representative family houses, from moderate and temperate climates, under different renovation processes (66 variants), with t......The scientific literature offers a number of methods for assessing the likelihood of overheating in buildings. The paper calculates eight well-documented indices for four representative family houses, from moderate and temperate climates, under different renovation processes (66 variants......), with the use of multi-zone energy software. In two out of four cases, the calculation included passive cooling measures for optimization purposes (shading, ventilative cooling). The analysis shows strong correlations between different methods-indices originating from the same comfort model theory independently...

  14. PCB i bygninger - afhjælpning, renovering og nedrivning

    DEFF Research Database (Denmark)

    Andersen, Helle Vibeke

    SBi-anvisning 268 beskriver, hvordan PCB-forurening af indeluften afhjælpes, og hvordan PCB håndteres, når man renoverer eller nedriver bygninger med PCB. Uanset om der er tale om afhjælpning, renovering eller nedrivning, kan arbejdet generere PCB-holdigt affald. Anvisningen forklarer derfor......, hvordan affaldet skal håndteres, og hvordan man beskytter mennesker og miljø under arbejdet. Anvisningen er baseret på byggebranchens erfaringer og den aktuelle forskningsbaserede viden om PCB i bygninger. SBi-anvisning 268 afløser den snart fire år gamle SBi-anvisning 242 om renovering af bygninger med...... PCB, som ikke behandlede spørgsmålet om affaldshåndtering....

  15. How to motivate homeowners to invest in sustainable renovation?

    DEFF Research Database (Denmark)

    Galiotto, Nicolas; Heiselberg, Per; Knudstrup, Mary-Ann

    2014-01-01

    important to integrate, aside the societal needs, the individual values which might motivate these decision-makers to undertake such a sustainable renovation. A critical review of decision-aid methods and tools, which are susceptible to be integrated in a process of home renovation, is presented...... in this paper. Methods have been primarily classified on the basis on whether or not they allow incorporating truthfully decision-makers’ individual values while still improving the process effectiveness. Reviewed tools have been classified as building analysis, optimization and decision making tools...... such as constructivist, interactive and iterative process, quantitative attributes and values based on qualitative judgments, simplicity and accuracy of the methods, time use and modularity are furthermore discussed. It is concluded that multi-criteria decision making approaches using interactive and constructivist...

  16. Experiment research of slag renovation in the corner-fired boiler

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Zhijun; Wu, Wenfei [Inner Mongolia Univ. of Science and Technology, Baotou (China). School of Energy and Environment

    2013-07-01

    Aiming at serious slag on the water wall around the burner of corner-fired boiler with low-ash-fusion-point coal, cold experimental model has been established. In this experiment, particle image velocimetry (PIV) has been employed to accurately measure aerodynamic field of burner region, and the experimental research of furnace slag renovation has been conducted through changing the burner jet arrangement. The experiment results show that it has significantly effect on aerodynamic field in the furnace by changing burner jet deflection angle. A reasonable actual tangential circle diameter can be formed through adjusting the burner jet deflection angle, to prevent primary air attacking the wall, and further more, to effectively prevent serious slag on the water wall around the burner.

  17. Effects of pasture renovation on hydrology, nutrient runoff, and forage yield.

    Science.gov (United States)

    de Koff, J P; Moore, P A; Formica, J; Van Eps, M; DeLaune, P B

    2011-01-01

    Proper pasture management is important in promoting optimal forage growth and reducing runoff and nutrient loss. Pasture renovation is a management tool that improves aeration by mechanically creating holes or pockets within the soil. Pasture renovation was performed before manure application (poultry litter or swine slurry) on different pasture soils and rainfall simulations were conducted to identify the effects of pasture renovation on nutrient runoff and forage growth. Renovation of small plots resulted in significant and beneficial hydrological changes. During the first rainfall simulation, runoff volumes were 45 to 74% lower for seven out of eight renovated treatments, and infiltration rates increased by 3 to 87% for all renovated treatments as compared with nonrenovated treatments. Renovation of pasture soils fertilized with poultry litter led to significant reductions in dissolved reactive P (DRP) (74-87%), total P (TP) (76-85%), and total nitrogen (TN) (72-80%) loads in two of the three soils studied during the first rainfall simulation. Renovation did not result in any significant differences in forage yields. Overall, beneficial impacts of renovation lasted up to 3 mo, the most critical period for nutrient runoff following manure application. Therefore, renovation could be an important best management practice in these areas.

  18. Residues of maneb in potatoes and lettuce and their persistence during cooking, washing and uv exposition

    International Nuclear Information System (INIS)

    Bennaceur, M.; Sennaoui, Z.; Zennouche, B.; Hylin, J.W.

    1992-01-01

    Lettuce plants were treated each with 0,186 mg of 14C maneb and 1,86 mg unlabelled maneb. The plants were analyzed 30 days later and subjected to washing. Washing eliminates 17,46% of total 14C maneb applied. No Etu was observed in water.Washing and baking cause a significant decrease of EBDC in potatoes samples and the UV exposition involves a decrease of the fungicide and a formation of Etu. On the other hand 54 % and 38% of lettuce and potatoe samples analyzed by CS2 method exceed the authorized norms

  19. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system; Idoneidad del agua de lavado de aceites de oliva como donador de electrones en un sistema alimentado por lotes bioelectroquímico

    Energy Technology Data Exchange (ETDEWEB)

    Fermoso, F.G.; Fernández-Rodríguez, M.J.; Jiménez-Rodríguez, A.; Serrano, A.; Borja, R.

    2017-07-01

    Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES) operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD) removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application. [Spanish] El agua de lavado del aceite de oliva procedente del proceso de elaboración en dos fases fue utilizada como donador de electrones en un Sistema Bioelectroquímico (BES) operado a 35ºC. Se realizó una etapa de arranque del sistema mediante alimentación con acetato, alcanzando un potencial de referencia de +680 mV. Tras 54 días, el sistema se alimentó con agua de lavado de aceite, generando un potencial máximo de +520 mV y una eliminación de materia del 41%, en demanda química de oxígeno. Sin embargo, cargas subsecuentes conllevaron una bajada en la eliminación de materia, mientras que la densidad de corriente y de potencia disminuyeron ostensiblemente. El empeoramiento de estos parámetros puede deberse a la acumulación de compuestos recalcitrantes o inhibidores, como fenoles. Por tanto, el uso del agua de lavado de aceite de oliva en un BES es factible, aunque es necesario llevar a cabo nuevas investigaciones que hagan más atractiva su aplicación a escala real.

  20. Energy Renovation of a Typical Danish Single-family House

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2007-01-01

    In 2006, new tighter energy performance requirements were introduced in Denmark for both new buildings and renovation, including a new classification system for low energy buildings. These demands are based on the directive on Energy Performance of Buildings, the EPBD (2002/91/EC). In general the...... available on the internet: http://www.rwsc.dk/EP_Villa_Projektrapport_RW_DK/main_report_villa.pdf....

  1. Bacteriological aspects of hand washing: A key for health promotion and infections control

    Directory of Open Access Journals (Sweden)

    Ramezan Ali Ataee

    2017-01-01

    Full Text Available The aim of this review is to show the historical aspects of hands washing for healthy life and explains how can reduce the transmission of community-acquired infectious agents by healthcare workers and patients. This review article is prepared based on available database. The key words used were hands washing, risk assessment, hands hygiene, bacterial flora, contamination, infection, nosocomial, tap water, sanitizer, bacterial resistance, hands bacterial flora, washing methods, antiseptics, healthcare workers, healthcare personnel, from PubMed, ScienceDirect, Embase, Scopus, Web of Sciences, and Google Scholar. Data were descriptively analyzed. The insistence on hand washing has a history of 1400 years. The research results indicate that the bacteria released from the female washed hands in wet and dry condition was lower than from the male′s hands with a significance level (3 CFU vs. 8 CFU; confidence interval 95%, P ≤ 0.001. The valuable results of the study indicated that released amount of bacterial flora from wet hands is more than 10 times in compared to dry hands. In addition, established monitoring systems for washing hands before and after patient′s manipulation as well as after toilet were dominant indices to prevent the transfer of infectious agents to the patients. Increasing awareness and belief of the healthcare workers have shown an important role by about 30% reduction in the transfection. Hand washing could reduce the episodes of transmission of infectious agents in both community and healthcare settings. However, hand washing is an important key factor to prevent transmission of infectious agents to patients. There is no standard method for measuring compliance. Thus, permanent monitoring of hand washing to reduce the transmission of infections is crucial. Finally, the personnel must believe that hand washing is an inevitable approach to infection control.

  2. The renovation of the Main Building is approaching completion

    CERN Multimedia

    Anaïs Schaeffer

    2011-01-01

    The renovation work under way in the CERN Main Building should be completed by June. From the floors to the ceilings, everything has been done to give this historic building a new lease of life.     Taken in the early 60s, this picture illustrates how light maintenance was a challenge for the auditorium in CERN’s main building.   Nobody who has recently had to shimmy between the cables, ladders and toolboxes deposited around the main hall of Building 500 to get to the post office, the bank or Restaurant 1 can be oblivious to the fact that the ground floor of the Main Building has been getting a face-lift. The renovation work, which started with the first-floor concourse in June 2010, should be finished over the next couple of months. The first-floor renovations, now almost complete, set the tone for the rest of the project. The floor and ceiling, both fitted with special acoustic materials for efficient noise damping, have been completely refurbished and the Building ...

  3. On the Testing of Renovations Inside Historical Opera Houses

    Science.gov (United States)

    Fausti, P.; Prodi, N.

    2002-11-01

    Due to the large number of historical opera houses in Italy, many theatres have been renovated in the past, but still more will undergo major restoration in the near future. Unfortunately in this context, the quality and protection of acoustics is rarely considered as an issue of its own. As a consequence, the renovations are hardly ever accompanied by proper scientific and technical support. In this paper, the acoustical impact of works inside the Teatro Municipale "R.Valli" in Reggio Emilia, including the restoration of the main hall and the construction of a new acoustic shell, will be dealt with. Surveys were held in the theatre before renovation and were repeated with identical procedure and instruments after its completion. By means of a comparative analysis of the architectural project and of acoustical data, the impact of major changes in the theatre can be predicted. It is shown that this approach can help in drafting an operational scheme for safeguarding the acoustics of historical opera houses.

  4. How to Successfully Renovate a Controls System? - Lessons Learned from the Renovation of the CERN Injectors’ Controls Software

    CERN Document Server

    Kruk, G; Kulikova, O; Lezhebokov, V; Pace, M; Pera Mira, P; Roux, E; Wozniak, J Pawel

    2014-01-01

    Renovation of the control system of the CERN LHC injectors was initiated in 2007 in the scope of the Injector Controls Architecture (InCA) project. One of its main objectives was to homogenize the controls software across CERN accelerators and reuse as much as possible the existing modern sub-systems, such as the settings management used for the LHC. The project team created a platform that would permit coexistence and intercommunication between old and new components via a dedicated gateway, allowing a progressive replacement of the former. Dealing with a heterogeneous environment, with many diverse and interconnected modules, implemented using different technologies and programming languages, the team had to introduce all the modifications in the smoothest possible way, without causing machine downtime. After a brief description of the system architecture, the paper discusses the technical and non-technical sides of the renovation process such as validation and deployment methodology, operational applicatio...

  5. Integrated project delivery methods for energy renovation of social housing

    Directory of Open Access Journals (Sweden)

    Tadeo Baldiri Salcedo Rahola

    2015-11-01

    Full Text Available Optimised project delivery methods forsocial housing energy renovations European Social Housing Organisations (SHOs are currently facing challenging times. The ageing of their housing stock and the economic crisis, which has affected both their finances and the finances of their tenants, are testing their capacity to stick to their aim of providing decent and affordable housing. Housing renovation projects offer the possibility of upgrading the health and comfort levels of their old housing stock to current standards and improve energy efficiency, and this solution also addresses the fuel poverty problems suffered by some tenants. Unfortunately, the limited financial capacity of SHOs is hampering the scale of housing renovation projects and the energy savings achieved.  At the same time, the renovation of the existing housing stock is seen as one of the most promising alternative routes to achieving the ambitious CO2 emissions reduction targets set by European authorities – namely, to reduce EU CO2 emissions to 20% below their 1990 levels by 2020. The synergy between European targets and the aims of SHOs has been addressed by the energy policies of the member states, which focus on the potential energy savings achievable by renovating social housing. In fact, the European initiatives have prioritised energy savings in social housing renovations to such an extent that these are referred to as ‘energy renovations’. Energy renovation is therefore a renovation project with higher energy savings target than a regular renovation project. In total, European SHOs own 21.5 million dwellings representing around 9.4% of the total housing stock. Each SHO owns a large number of dwellings, which means there are fewer people to convince of the need to make energy savings through building renovations, maximising the potentially high impact of decisions. Moreover, SHOs are responsible for maintaining and upgrading their properties in order to continue

  6. Effects of household washing on bacterial load and removal of Escherichia coli from lettuce and "ready-to-eat" salads.

    Science.gov (United States)

    Uhlig, Elisabeth; Olsson, Crister; He, Jiayi; Stark, Therese; Sadowska, Zuzanna; Molin, Göran; Ahrné, Siv; Alsanius, Beatrix; Håkansson, Åsa

    2017-11-01

    Customer demands for fresh salads are increasing, but leafy green vegetables have also been linked to food-borne illness due to pathogens such as Escherichia coli O157:H7. As a safety measure, consumers often wash leafy vegetables in water before consumption. In this study, we analyzed the efficiency of household washing to reduce the bacterial content. Romaine lettuce and ready-to-eat mixed salad were washed several times in flowing water at different rates and by immersing the leaves in water. Lettuce was also inoculated with E. coli before washing. Only washing in a high flow rate (8 L/min) resulted in statistically significant reductions ( p  < .05), "Total aerobic count" was reduced by 80%, and Enterobacteriaceae count was reduced by 68% after the first rinse. The number of contaminating E. coli was not significantly reduced. The dominating part of the culturable microbiota of the washed lettuce was identified by rRNA 16S sequencing of randomly picked colonies. The majority belonged to Pseudomonadaceae , but isolates from Enterobacteriaceae and Staphylococcaceaceae were also frequently found. This study shows the inefficiency of tap water washing methods available for the consumer when it comes to removal of bacteria from lettuce. Even after washing, the lettuce contained high levels of bacteria that in a high dose and under certain circumstances may constitute a health risk.

  7. Tenants’ experiences and satisfaction with renovated and energy retrofitted social housing

    DEFF Research Database (Denmark)

    Knudsen, Henrik Nellemose; Jensen, Ole Michael

    studied and verified. The objective of the present project was to evaluate tenants’ experiences and satisfaction with renovated and energy retrofitted social housing. A questionnaire was developed that included questions about perceived indoor climate, possible co-benefits, the renovation process, various....... The evaluations show that it is possible to implement a comprehensive renovation with focus on energy savings in older building stock and at the same time add value for tenants in the form of i.a. improved perceived indoor climate....

  8. Holistic Energy Renovation of Pre- and Postwar Apartment Blocks in Denmark

    DEFF Research Database (Denmark)

    Eriksen, Marlene Stenberg Hagen; Rode, Carsten; Bjarløv, Søren Peter

    of today. This paper presents the Danish research project Holistic Energy Renovation, which aims at performing a holistic energy renovation of two case buildings. As part of the project nine parameters for a holistic renovation have been defined, a method for developing and assessing a holistic building...... of the assessment method and an evaluation of how the holistic perspective has influenced the project process and product development....

  9. Renovation versus New Construction and Building Decision Tool for Educational Facilities

    OpenAIRE

    Pope, Carrie; Marks, Eric; Back, Edward; Leopard, Tim; Love, Thomas

    2016-01-01

    Renovation of an existing building is an accomplished stem of the construction industry because it supplies financial diversification for construction stakeholders. Although several construction planning tools and stakeholder alignment exercises have been developed, no tool exists to assist project owners to decide between renovating an existing building and new construction with a comprehensive decision criteria. The objective of this research is to create and test a renovation versus new bu...

  10. Soil washing: From characterization to implementation

    International Nuclear Information System (INIS)

    Corden, F.L.; Groenendijk, E.

    1995-01-01

    Only recently has soil washing begun to be applied to remediation of contaminated soils in the US. The experience gained during full-scale and large pilot-scale projects points to the importance of soil and site characterization in correctly evaluating the applicability of soil washing to a site and determining accurate cost estimates for its implementation. This paper will discuss actual case studies of various treatability and pilot study approaches that led to successful evaluation and implementation of soil washing remedies. Soil washing is applicable to a broad variety of chemical contaminants. Target contaminants include metals, radionuclides, pesticides, polychlorinated biphenyls, polynuclear aromatic hydrocarbons and petroleum hydrocarbons, as well as combinations of these contaminants. Because the contaminants noted above are deposited in the soils in a variety of forms, the unit operations necessary to treat the soil vary. It is the diversity of the available treatment alternatives, and the ability to use the units in a variety of process flow configurations that result in a very broad definition of soil washing

  11. Washing of waste prior to landfilling.

    Science.gov (United States)

    Cossu, Raffaello; Lai, Tiziana

    2012-05-01

    The main impact produced by landfills is represented by the release of leachate emissions. Waste washing treatment has been investigated to evaluate its efficiency in reducing the waste leaching fraction prior to landfilling. The results of laboratory-scale washing tests applied to several significant residues from integrated management of solid waste are presented in this study, specifically: non-recyclable plastics from source separation, mechanical-biological treated municipal solid waste and a special waste, automotive shredded residues. Results obtained demonstrate that washing treatment contributes towards combating the environmental impacts of raw wastes. Accordingly, a leachate production model was applied, leading to the consideration that the concentrations of chemical oxygen demand (COD) and total Kjeldahl nitrogen (TKN), parameters of fundamental importance in the characterization of landfill leachate, from a landfill containing washed wastes, are comparable to those that would only be reached between 90 and 220years later in the presence of raw wastes. The findings obtained demonstrated that washing of waste may represent an effective means of reducing the leachable fraction resulting in a consequent decrease in landfill emissions. Further studies on pilot scale are needed to assess the potential for full-scale application of this treatment. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Hydraulic washing removal efficiencies of Orimulsion from rock surfaces

    International Nuclear Information System (INIS)

    Harper, J.R.; Ward, S.; Sergy, G.

    2002-01-01

    Orimulsion is a fuel alternative composed of 70 per cent bitumen in 30 per cent water. It is shipped from Venezuela to New Brunswick where it is used as fuel oil for power plants. While there have not been any major spills of Orimulsion, it is recognized that very little is known regarding the dispersal and weathering processes of Orimulsion, or the behaviour and cleanup of the product on both rocky and course sediment shorelines. For that reason, this study was conducted to determine the efficiency of hydraulic washing under different water temperatures and pressures to remove bitumen from rocky shorelines. The results of the study make it possible to assess the physical effectiveness of the method and to determine the range of effective operational parameters. The coating protocol was refined to create uniform coating of both dispersed and coalesced bitumen of rock surfaces. The use of a chemical agent for enhancing removal efficiency was also assessed. Orimulsion could reach shorelines as low concentration dispersions of bitumen particles suspended in a water column, or as a high concentration mixture of bitumen, water and air. Granite tiles were coated with uniform coatings of both dispersed and coalesced bitumen. They were then washed under different pressures, temperatures and other treatments. Temperatures of more than 40 degrees C and pressures of more than 76 kPa were needed to effectively remove the bitumen coatings. Weathering significantly increased coating tenacity for dispersed coatings, but did not affect coalesced coating tenacity. Immediate washing was found to be very effective for removing dispersed coating, but not for coalesced coating. Coating tenacity was also affected by submergence times. Pre-treatment of the coating with a dispersion called Corexit significantly improved the removal efficiencies of dispersed coatings, but not coalesced coatings. 6 refs., 10 tabs., 5 figs

  13. 30 CFR 206.459 - Allocation of washed coal.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Allocation of washed coal. 206.459 Section 206... MANAGEMENT PRODUCT VALUATION Indian Coal § 206.459 Allocation of washed coal. (a) When coal is subjected to washing, the washed coal must be allocated to the leases from which it was extracted. (b) When the net...

  14. 30 CFR 206.260 - Allocation of washed coal.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Allocation of washed coal. 206.260 Section 206... MANAGEMENT PRODUCT VALUATION Federal Coal § 206.260 Allocation of washed coal. (a) When coal is subjected to washing, the washed coal must be allocated to the leases from which it was extracted. (b) When the net...

  15. Evaluation of microplastic release caused by textile washing processes of synthetic fabrics.

    Science.gov (United States)

    De Falco, Francesca; Gullo, Maria Pia; Gentile, Gennaro; Di Pace, Emilia; Cocca, Mariacristina; Gelabert, Laura; Brouta-Agnésa, Marolda; Rovira, Angels; Escudero, Rosa; Villalba, Raquel; Mossotti, Raffaella; Montarsolo, Alessio; Gavignano, Sara; Tonin, Claudio; Avella, Maurizio

    2018-05-01

    A new and more alarming source of marine contamination has been recently identified in micro and nanosized plastic fragments. Microplastics are difficult to see with the naked eye and to biodegrade in marine environment, representing a problem since they can be ingested by plankton or other marine organisms, potentially entering the food web. An important source of microplastics appears to be through sewage contaminated by synthetic fibres from washing clothes. Since this phenomenon still lacks of a comprehensive analysis, the objective of this contribution was to investigate the role of washing processes of synthetic textiles on microplastic release. In particular, an analytical protocol was set up, based on the filtration of the washing water of synthetic fabrics and on the analysis of the filters by scanning electron microscopy. The quantification of the microfibre shedding from three different synthetic fabric types, woven polyester, knitted polyester, and woven polypropylene, during washing trials simulating domestic conditions, was achieved and statistically analysed. The highest release of microplastics was recorded for the wash of woven polyester and this phenomenon was correlated to the fabric characteristics. Moreover, the extent of microfibre release from woven polyester fabrics due to different detergents, washing parameters and industrial washes was evaluated. The number of microfibres released from a typical 5 kg wash load of polyester fabrics was estimated to be over 6,000,000 depending on the type of detergent used. The usage of a softener during washes reduces the number of microfibres released of more than 35%. The amount and size of the released microfibres confirm that they could not be totally retained by wastewater treatments plants, and potentially affect the aquatic environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Plutonium recovery from carbonate wash solutions

    International Nuclear Information System (INIS)

    Gray, J.H.; Reif, D.J.; Chostner, D.F.; Holcomb, H.P.

    1991-01-01

    540Periodically higher than expected levels of plutonium are found in carbonate solutions used to wash second plutonium cycle solvent. The recent accumulation of plutonium in carbonate wash solutions has led to studies to determine the cause of that plutonium accumulation, to evaluate the quality of all canyon solvents, and to develop additional criteria needed to establish when solvent quality is acceptable. Solvent from three canyon solvent extraction cycles was used to evaluate technology required to measure tributyl phosphate (TBP) degradation products and was used to evaluate solvent quality criteria during the development of plutonium recovery processes. 1 fig

  17. Washing of gel particles in wet chemical manufacture of reactor fuel particles

    International Nuclear Information System (INIS)

    Ringel, H.

    1980-07-01

    In the manufacture of HTR fuel particles and particles of fertile material by wet chemical methods, the ammonium nitrate formed during the precipitation reaction must be washed out of the gel particles. This washing process has been investigated theoretically and experimentally. A counter-current washer has been developed which in particular takes account of the aspects of refabrication - such as compact construction and minimum waste. A counter-current washing column of 17 mm internal diameter and 640 mm length gives to gel particle throughput of 0.65 1/h. The volume ratio of wash water to gel particles is 5, and the residual nitrate concentration in the particles is 7 x 10 -3 mols of NO - 3 /1. (orig.) [de

  18. Evaluation of the effects of repeated hand washing, sunlight, smoke and dirt on the persistence of deltamethrin on insecticide-treated nets.

    Science.gov (United States)

    Kayedi, M H; Lines, J D; Haghdoost, A A; Vatandoost, M H; Rassi, Y; Khamisabady, K

    2008-08-01

    Field studies were carried out in Iran to evaluate the effect of various factors (washing, sun, smoke, dust and dirt) on the residual insecticidal activity of PermaNet (a brand of long-lasting insecticidal net), and on nets conventionally treated with deltamethrin (K-O Tab), using bioassay tests. Thirty-two nets were washed five or 15 times, and eight nets were not washed at all. Nets were washed vigorously in cold tap water (17 degrees C, pH 8.9) with a detergent. Hand rubbing continued for 3min. After washing, some nets were exposed to dense smoke from a dung-hay fire for 3min and were also left exposed to the dusty wind between washes. One group of nets was exposed to the sunlight for the full 3-d interval between washes; another was exposed to sunlight for just 3h after each wash; two other groups were kept in the shade. There was a significantly greater loss of activity in nets exposed to the sun throughout the 3-d interval between washes: that is, for a total of 15 to 45 d. However, short sunlight exposure (maximum 3h between washes) during drying did not have any effect. We did not find any significant effect of exposure to dirt, dust and smoke after washing. It is concluded that the effect of sun is much smaller than that of washing, and that drying nets for a few hours in the sun is not harmful.

  19. Applications of the renewable energies; Aplicaciones de las energias renovables

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Rocha, Luis Martin [Comision Nacional para el Ahorro de Energia, Mexico, D.F. (Mexico)

    2001-07-01

    The solar energy manifests itself in different forms and its application has been fundamental for the humankind development. These forms are known as renewable energies, since they are energy forms that are renewed or remade with time or that are so abundant on Earth, that they will last for hundreds or thousands of years, either we use them or not. The main advantage of the utilization of the renewable energies in comparison with hydrocarbons is the one of having smaller impact on the environment, which brings about the conservation of nonrenewable resources, and to postpone its exhaustion. They allow the distributed generation, diminishing the power losses in the transmission and distribution systems, which increases the overall efficiency. In addition they can be the drive for regional development and generation of employment, because when having applications in remote zones and being a field still not completely developed in Mexico, the possibility exists of enabling professionals and technicians. From the point of view of the power sector, the renewable energies extend the supply and availability of energy, making more flexible and independent the operation and reliability of the national power system. [Spanish] La energia solar se manifiesta de diversas formas y su aplicacion ha sido fundamental para el desarrollo de la humanidad. A estas formas se les conoce como energias renovables, ya que son formas de energia que se van renovando o rehaciendo con el tiempo o que son tan abundantes en la tierra, que perduraran por cientos o miles de anos, las usemos o no. La principal ventaja del aprovechamiento de las energias renovables en comparacion con los hidrocarburos es la de tener menor impacto al medio ambiente, lo que trae consigo la conservacion de recursos no renovables, y posponer su termino. Permiten la generacion distribuida, disminuyendo las perdidas energeticas en los sistemas de transmision y distribucion, lo que incrementa la eficiencia general. Ademas

  20. Prerequisites for Successful Strategic Partnerships for Sustainable Building Renovation

    DEFF Research Database (Denmark)

    Jensen, Per Anker; Johansen, Jakob Berg; Thuesen, Christian

    2017-01-01

    and analysis of strategic partnerships models as well as typical processes used in building renovation. Experiences from development of new strategic partnerships have particularly been found in the UK and Sweden. Based on two workshops with practitioners representing the whole value chain in the construction...... particularly in terms of reducing energy consumption and use of resources and increase productivity. However, until now we have only had a limited number of such partnerships implemented and the few examples that do exist, mostly concern the construction of new buildings. The paper is based on an investigation...

  1. Defining Sustainability in Relation to the Renovation of Modern Housing

    DEFF Research Database (Denmark)

    Peters, Terri

    Summary This paper focuses on comparing practice-based and academic definitions and metrics of “sustainability” as they relate to the transformation of Modern housing in Denmark. Keywords:Sustainability, Renovation, Architecture, Denmark, Modern housing 1. Introduction to the Study Buildings...... define and understand what constitutes green design, but also to understand its premises for it would be counter productive for the designer to leap into green design without understanding and agreeing to such basic principles as connectedness”. In recent years, a new way of thinking about sustaina...

  2. Development of a method for holistic energy renovation

    DEFF Research Database (Denmark)

    Morelli, Martin

    recovery. The long-term performance of the renovation may be reduced due to mould growth behind the interior insulation or decay of the wooden beams. The energy saving potential in two multi-family buildings was investigated by parameter studies of existing energy saving measures for both the building....... Measurements of temperature and relative humidity showed that conditions for mould growth were present. However, no signs of mould growth were documented at dismantling of the interior insulation. A method was developed for the design of energy saving measures based on both Failure Mode and Effect Analysis...

  3. Disseny d'una microxarxa amb generació renovable

    OpenAIRE

    Durich Serra, Ruben

    2016-01-01

    El present projecte pretén abordar l’estudi dels costs de generació d’energia elèctrica renovable de la tecnologia solar-fotovoltaica per tal de formar part del disseny d’una microxarxa de generació d’energia elèctrica. Durant la realització del projecte s’ha realitzat una breu introducció a les microxarxes de distribució d’energia elèctrica i als seus reptes. Per estudiar el cost de generació d’energia fotovoltaica s’ha utilitzat la metodologia del Levelized Cost of Energy ...

  4. Contracting and building renovation - does it work together?

    Energy Technology Data Exchange (ETDEWEB)

    Tritthart, Wibke; Bruner-Lienhart, Susanne [Inter-Univ. Research Centre for Technology, Work and Culture, Graz (Austria); Bleyl, Jan W.; Bucar, Gerhard [Graz Energy Agency (Austria)

    2007-07-01

    The renovation or refurbishment is an important point in the life cycle of a building that makes it possible to achieve both environmental and climate protection goals and a higher quality of living of the inhabitants. However, lack of money often leads to a renovation that covers only the basic requirements, whereas measures that are valuable in a long term perspective like energy saving measures are not realised. Energy performance contracting (EPC) is widely used as an instrument to reduce long term operating costs significantly by guaranteed energy savings. An energy service company (ESCo) implements saving technologies, especially in the field of heating, HVAC, lighting and plug loads, and in particular in public buildings. It is the aim of this paper to investigate the possibilities to incorporate construction measures like building envelope insulation into standard energy performance contracting.For this purpose a qualitative survey is presented that was performed among experts and stakeholders in the business: ESCos, building owners and facility managers, representatives of construction companies and financing institutions were interviewed. The focus was on their experiences with such projects, on difficulties that arose or barriers that exist from their point of view and on the chances they perceived. This provides the basis for identifying restraints and supporting factors for the integration of contracting and constructional measures.Three pilot projects that have been renovated in Austria are outlined subsequently. They are evaluated with respect to the contractual network between the project partners, types of guarantees and financing issues. Special emphasis is put on the assignment of tasks and the cash flow between the project partners. Various constellations of trades acted as energy service provider: a general contractor, an energy supply company, a consortium of a builder and a plumber. The projects reveal some differences to the standard energy

  5. " La chatarra ferrosa, ¿desperdicio industrial o recurso renovable?"

    OpenAIRE

    Valadez Valenzuela, Jaime arturo

    2011-01-01

    Conforme el avance del tiempo, y el deterioro o consumismo de los recursos renovables por el paso desenfrenado de nuestra humanidad, enfrentando el reto de subsistencia en todos los ámbitos, se nos esta presentando la necesidad de aprovechar todo aquello que de una u otra forma pueda ser reutilizado, generando inclusive la forma de otorgar "trabajo", o una manera de crear fuentes económicas para toda una gama de personas, que de tal manera que dedicándose tanto a la recolección de lo que par...

  6. Use of green washing fluids in a washing process for dioxin contaminated soils

    Directory of Open Access Journals (Sweden)

    Siwalee Yotapukdee

    2017-09-01

    Full Text Available High levels of dioxin contamination in soil have significant environmental challenges. Soil washing is a successful remediation process that is primarily used to treat coarse soils. Several literature studies have used various kinds of chemical washing liquids to remove dioxins from soils, though there are secondary environmental effects. This study intends to develop environmentally friendly soil washing methods that are effective in dioxin removal at an acceptable cost. Sugarcane wine, compost leachate, and ground fish broth were chosen as potential washing liquids. Each washing liquid was analyzed to determine its content of semivolatile organic compounds (SVOCs and volatile organic compounds (VOCs. These compounds are related to their bio-surfactant content. Several of the identified compounds had properties to help remove dioxins from contaminated soil. In the experiments, high removal efficiencies were observed, up to 70%~95% after five to six washes. Although effective removal was observed, a significant amount of wastewater was produced and the problems were not completely resolved. Thus, the optimal washing conditions are necessary to minimize the overall costs, while improving the process effectiveness. Moreover, an appropriate treatment method is required for wastewater containing dioxins.

  7. Water and future

    International Nuclear Information System (INIS)

    2010-03-01

    This is material of the 18th world water day in 2010 which reports current situation of water resources such as water world, in water in Korea and water dispute, water and disaster like climate change, flood, drought, historical report about drought and flood, water resources facilities in Korea, disaster management system, development and management of eco-friendly water resources, eco-friendly water resources management and river maintenance, renovating four rivers and supply and procure of safe water.

  8. SOIL-WASHING TECHNOLOGY AND PRACTICE

    Science.gov (United States)

    Soil washing in the United States has been studied and evaluated with increasing thoroughness during the last 15 to 20 years. It is now entering a phase of actual use and acceptance as its applicability and economics become clearer. This paper reviews the principles behind soil...

  9. 100 Area soil washing treatability test plan

    International Nuclear Information System (INIS)

    1993-03-01

    This test plan describes specifications, responsibilities, and general methodology for conducting a soil washing treatability study as applied to source unit contamination in the 100 Area. The objective ofthis treatability study is to evaluate the use of physical separation systems and chemical extraction methods as a means of separating chemically and radioactively contaminated soil fractions from uncontaminated soil fractions. The purpose of separating these fractions is to minimize the volume of soil requiring permanent disposal. It is anticipated that this treatability study will be performed in two phases of testing, a remedy screening phase and a remedy selection phase. The remedy screening phase consists of laboratory- and bench-scale studies performed by Battelle Pacific Northwest laboratories (PNL) under a work order issued by Westinghouse Hanford Company (Westinghouse Hanford). This phase will be used to provide qualitative evaluation of the potential effectiveness of the soil washing technology. The remedy selection phase, consists of pilot-scale testing performed under a separate service contract to be competitively bid under Westinghouse Hanford direction. The remedy selection phase will provide data to support evaluation of the soil washing technology in future feasibility studies for Interim Remedial Measures (IRMs) or final operable unit (OU) remedies. Performance data from these tests will indicate whether applicable or relevant and appropriate requirements (ARARs) or cleanup goals can be met at the site(s) by application of soil washing. The remedy selection tests wig also allow estimation of costs associated with implementation to the accuracy required for the Feasibility Study

  10. Environmental control during steam boiler washing

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcio A.B.; Abreu Pereira, Vera L. de [Companhia Petroquimica do Nordeste (COPENE), Camacari, BA (Brazil). Div. de Engenharia Ambiental; Ringler, Ulrich E.S. [PROMON Engenharia Ltda., Salvador, BA (Brazil)

    1993-12-31

    The washing and chemical cleaning of boilers, activities of a high polluting potential, are responsible for the generation of wastewater of high contents of heavy metals, suspended solids and chemical oxygen demand (COD). This paper describes the actions carried out by COPENE - Petroquimica do Nordeste S/A - in order to reduce this problem. (author). 10 refs., 3 figs., 2 tabs.

  11. Environmental control during steam boiler washing

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcio A.B.; Abreu Pereira, Vera L. de [Companhia Petroquimica do Nordeste (COPENE), Camacari, BA (Brazil). Div. de Engenharia Ambiental; Ringler, Ulrich E.S. [PROMON Engenharia Ltda., Salvador, BA (Brazil)

    1994-12-31

    The washing and chemical cleaning of boilers, activities of a high polluting potential, are responsible for the generation of wastewater of high contents of heavy metals, suspended solids and chemical oxygen demand (COD). This paper describes the actions carried out by COPENE - Petroquimica do Nordeste S/A - in order to reduce this problem. (author). 10 refs., 3 figs., 2 tabs.

  12. What Happens at a Car Wash?

    Science.gov (United States)

    Gallick, Barbara; Lee, Lisa

    2010-01-01

    A class of 3- to 5-year-old children in a child care center in the midwestern United States chose to study a car wash as a group project. This article discusses how the project evolved, describes the three phases of the project, and provides the teachers' reflections on the project. Photos taken during the project and children's sketches are…

  13. A method for treating clayless wash fluids

    Energy Technology Data Exchange (ETDEWEB)

    Deykalo, T A; Dzhumagaliyev, T N; Skvortsov, D S

    1980-02-18

    To increase the heat and salt resistance of a wash fluid, monoethanolamine processed waste of licorice production - grist in a volume of 5-8% by weight, is introduced into it as the disperse phase. The processing of the grist is conducted for 1-2 hours at 20-100/sup 0/C and the volume of the monoethanolamine is 0.05-0.1% by weight. The properties of the washing fluids treated by the grist with the introduction of 20% CaC1/sub 2/ into them were not deteriorated, while complete coagulation was achieved with its introduction into washing fluids on the basis of KMTs. Grist washing liquids do not deteriorate their own properties to a temperature of 200/sup 0/C, do not cause equipment corrosion, are inert to swelling clay rocks and with the introduction of KMTs at a temperature above 130-140/sup 0/C cause insignificant destruction of the reagent which is accompanied by a change in the color of the solutions and a drop in the degree of polymerization and viscosity.

  14. On Stakeholders and the Decision Making Process Concerning Sustainable Renovation and Refurbishment in Sweden, Denmark and Cyprus

    DEFF Research Database (Denmark)

    Gohardani, Navid; Björk, Folke; Jensen, Per Anker

    2013-01-01

    This article examines the decision making process related to sustainable renovation and refurbishment in buildings. The utilized methodology identifies three distinct phases in order to instigate an engagement in sustainable renovation, by means of questionnaires and semi-structured interviews...

  15. 40 CFR 745.326 - Renovation: State and Tribal program requirements.

    Science.gov (United States)

    2010-07-01

    ... sampling technician training programs. (ii) Procedures and requirements for the certification of renovators and dust sampling technicians. (iii) Procedures and requirements for the certification of individuals..., 2010. For the convenience of the user, the added text is set forth as follows: § 745.326 Renovation...

  16. Opportunities and Barriers related to Supply Chain Collaboration for Delivering Integrated Single-Family Home Renovations

    NARCIS (Netherlands)

    Mlecnik, E.; Kondratenko, I.; Haavik, T.

    2013-01-01

    Single-family home renovations often show deficiencies in project management. There might be a market addressing house owners who would prefer integrated renovation services and clear responsibilities. Companies that would respond to these client’s needs would have a clear market potential,

  17. Generation of components for software renovation factories from context-free grammars

    NARCIS (Netherlands)

    Brand, van den M.G.J.; Sellink, M.P.A.; Verhoef, C.

    2000-01-01

    We present an approach for the generation of components for a software renovation factory. These components are generated from a contex-free grammar definition that recognizes the code that has to be renovated. We generate analysis and transformation components that can be instantiated with a

  18. Sustainability Evaluation of Retrofitting and Renovation of Buildings in Early Stages

    DEFF Research Database (Denmark)

    Jensen, Per Anker; Maslesa, Esmir; Gohardani, Navid

    2013-01-01

    research results and ideas for the development of a tool, which can be used as decision support for renovation projects in early stages. The research is part of the Eracobuild project ACES – “A concept for promotion of sustainable retrofitting and renovation in early stages” with participants from Denmark...

  19. Historic Schools: Renovation vs. Replacement & the Role of a Feasibility Study.

    Science.gov (United States)

    National Trust for Historic Preservation, Washington, DC.

    Weighing the pros and cons of renovating a historic neighborhood school or building a new one takes preservation "know-how," experience, and creativity. The potential for renovation is routinely dismissed without full consideration of the facts and long-term implications. Central to this decision-making process is the feasibility study,…

  20. May car washing represent a risk for Legionella infection?

    Science.gov (United States)

    Baldovin, T; Pierobon, A; Bertoncello, C; Destefani, E; Gennari, M; Stano, A; Baldo, V

    2018-01-01

    Legionella is a ubiquitous Gram-negative bacterium naturally found in aquatic environments. It can pose a health problem when it grows and spreads in man-made water systems. Legionella pneumophila is the most common cause of Legionnaires' disease nowadays, a community-acquired pneumonia with pulmonary symptoms and chest radiography no different from any other form of infectious pneumonia. Legionella monitoring is important for public health reasons, including the identification of unusual environmental sources of Legionella. We report two cases of Legionnaires' disease associated with two different car wash installations in the province of Vicenza, in the Veneto region, northeastern Italy. Patients were not employees of the car wash installations, but users of the service. In both cases, Legionella antigen was detected in urine using the Alere BinaxNOW® Legionella Urinary Antigen, and Legionella antibodies were detected in serum using SERION ELISA classic Legionella pneumophila 1-7 IgG and IgM. Water samples were also analyzed as part of the surveillance program for Legionella prevention and control in compliance with the Italian guidelines. Both patients had clinical symptoms and chest radiography compatible with pneumonia, and only one of them had diabetes as a risk factor. Legionella urinary antigen and serological test on serum samples were positive for Legionella in both patients, even if much slighter in the case A due to the retrospective serological investigation performed a year later the episode and after the second clinical case occurred in the same district. The environmental investigations highlighted two different car wash plants as potential source of infection. A certified company using shock hyperchlorination was asked to disinfect the two plants and, subsequently, control samples resulted negative for Legionella pneumophila. Any water source producing aerosols should be considered at risk for the transmission of Legionella bacteria, including car

  1. Mobilization for energy renovation. Innovative tools for the uptake of deep renovation of the existing building stock based on behavioural insights

    OpenAIRE

    Taranu, Victoria; Verbeeck, Griet

    2015-01-01

    Mobilization for energy renovation. Innovative tools for the uptake of deep renovation of the existing building stock based on behavioural insights. In the context of climate change it is a priority to reduce the energy demand and make a shift towards renewable sources of energy. In Flanders almost half of the existing residential building stock was built before 1970 with low levels of insulation and inefficient installations. The vast majority of Fle...

  2. Exploring the gap between hand washing knowledge and practices in Bangladesh: a cross-sectional comparative study.

    Science.gov (United States)

    Rabbi, Sifat E; Dey, Nepal C

    2013-01-30

    Hand washing is considered as one of the most effective hygiene promotion activities for public health in developing countries. This study compared hand washing knowledge and practices in BRAC's water; sanitation and hygiene (WASH) programme areas over time. This study is a cross-sectional comparative study between baseline (2006), midline (2009) and end-line (2011) surveys in 50 sub-districts from the first phase of the programme. Thirty thousand households from 50 sub-districts were selected in two steps: i) 30 villages were selected from each sub-district by cluster sampling, and ii) 20 households were chosen systematically from each village. The matched households were considered (26,404 in each survey) for analysis. Data were collected from households through face-to-face interview using a pre-tested questionnaire. Respondents were the adult female members of the same households, who had knowledge of day-to-day household activities related to water, sanitation and hygiene. A gap between perception and practice of proper hand washing practices with soap was identified in the study areas. Hand washing practice with soap before eating was much lower than after defecation. In baseline data, 8% reported to wash their hands with soap which significantly increased to 22% in end line. Hand washing knowledge and practices before cooking food, before serving food and while handling babies is considerably limited than other critical times. A multivariate analysis shows that socio-economic factors including education of household head and respondent, water availability and access to media have strong positive association with hand washing with soap. Gap between knowledge and practice still persists in hand washing practices. Long term and extensive initiatives can aware people about the effectiveness of hand washing.

  3. Exploring the gap between hand washing knowledge and practices in Bangladesh: a cross-sectional comparative study

    Directory of Open Access Journals (Sweden)

    Rabbi Sifat E

    2013-01-01

    Full Text Available Abstract Background Hand washing is considered as one of the most effective hygiene promotion activities for public health in developing countries. This study compared hand washing knowledge and practices in BRAC’s water; sanitation and hygiene (WASH programme areas over time. Methods This study is a cross-sectional comparative study between baseline (2006, midline (2009 and end-line (2011 surveys in 50 sub-districts from the first phase of the programme. Thirty thousand households from 50 sub-districts were selected in two steps: i 30 villages were selected from each sub-district by cluster sampling, and ii 20 households were chosen systematically from each village. The matched households were considered (26,404 in each survey for analysis. Data were collected from households through face-to-face interview using a pre-tested questionnaire. Respondents were the adult female members of the same households, who had knowledge of day-to-day household activities related to water, sanitation and hygiene. Results A gap between perception and practice of proper hand washing practices with soap was identified in the study areas. Hand washing practice with soap before eating was much lower than after defecation. In baseline data, 8% reported to wash their hands with soap which significantly increased to 22% in end line. Hand washing knowledge and practices before cooking food, before serving food and while handling babies is considerably limited than other critical times. A multivariate analysis shows that socio-economic factors including education of household head and respondent, water availability and access to media have strong positive association with hand washing with soap. Conclusion Gap between knowledge and practice still persists in hand washing practices. Long term and extensive initiatives can aware people about the effectiveness of hand washing.

  4. Tank 4 Characterization, Settling, And Washing Studies

    International Nuclear Information System (INIS)

    Bannochie, C.; Pareizs, J.; Click, D.; Zamecnik, J.

    2009-01-01

    A sample of PUREX sludge from Tank 4 was characterized, and subsequently combined with a Tank 51 sample (Tank 51-E1) received following Al dissolution, but prior to a supernate decant by the Tank Farm, to perform a settling and washing study to support Sludge Batch 6 preparation. The sludge source for the majority of the Tank 51-E1 sample is Tank 12 HM sludge. The Tank 51-E1 sample was decanted by SRNL prior to use in the settling and washing study. The Tank 4 sample was analyzed for chemical composition including noble metals. The characterization of the Tank 51-E1 sample, used here in combination with the Tank 4 sample, was reported previously. SRNL analyses on Tank 4 were requested by Liquid Waste Engineering (LWE) via Technical Task Request (TTR) HLE-TTR-2009-103. The sample preparation work is governed by Task Technical and Quality Assurance Plan (TTQAP), and analyses were controlled by an Analytical Study Plan and modifications received via customer communications. Additional scope included a request for a settling study of decanted Tank 51-E1 and a blend of decanted Tank 51-E1 and Tank 4, as well as a washing study to look into the fate of undissolved sulfur observed during the Tank 4 characterization. The chemistry of the Tank 4 sample was modeled with OLI Systems, Inc. StreamAnalyzer to determine the likelihood that sulfate could exist in this sample as insoluble Burkeite (2Na 2 SO 4 · Na 2 CO 3 ). The OLI model was also used to predict the composition of the blended tank materials for the washing study. The following conclusions were drawn from the Tank 4 analytical results reported here: (1) Any projected blend of Tank 4 and the current Tank 51 contents will produce a SB6 composition that is lower in Ca and U than the current SB5 composition being processed by DWPF. (2) Unwashed Tank 4 has a relatively large initial S concentration of 3.68 wt% on a total solids basis, and approximately 10% of the total S is present as an insoluble or undissolved form

  5. Effect and Removal Mechanisms of 6 Different Washing Agents for Building Wastes Containing Chromium

    Directory of Open Access Journals (Sweden)

    Wang Xing-run

    2012-01-01

    Full Text Available With the building wastes contaminated by chromium in Haibei Chemical Plan in China as objects, we studied the contents of total Cr and Cr (VI of different sizes, analyzed the effect of 6 different washing agents, discussed the removal mechanisms of 6 different washing agents for Cr in various forms, and finally selected applicable washing agent. As per the results, particle size had little impact on the contents of total Cr and Cr (VI; after one washing with water, the removal rate of total Cr and Cr (VI was 75% and 78%, respectively, and after the second washing with 6 agents, the removal rate of citric acid was the highest, above 90% for total Cr and above 99% for hexavalent chromium; the pH of building wastes were reduced by citric acid, and under acid condition, hexavalent chromium was reduced to trivalent chromium spontaneously by organic acid, which led to better removal rate of acid soluble Cr and reducible Cr; due to the complexing action, citric acid had best removal rate for oxidizable trivalent chromium. In conclusion, citric acid is the most applicable second washing agent for building wastes.

  6. Hand washing promotion for preventing diarrhoea.

    Science.gov (United States)

    Ejemot-Nwadiaro, Regina I; Ehiri, John E; Arikpo, Dachi; Meremikwu, Martin M; Critchley, Julia A

    2015-09-03

    Diarrhoea accounts for 1.8 million deaths in children in low- and middle-income countries (LMICs). One of the identified strategies to prevent diarrhoea is hand washing. To assess the effects of hand washing promotion interventions on diarrhoeal episodes in children and adults. We searched the Cochrane Infectious Diseases Group Specialized Register (27 May 2015); CENTRAL (published in the Cochrane Library 2015, Issue 5); MEDLINE (1966 to 27 May 2015); EMBASE (1974 to 27 May 2015); LILACS (1982 to 27 May 2015); PsycINFO (1967 to 27 May 2015); Science Citation Index and Social Science Citation Index (1981 to 27 May 2015); ERIC (1966 to 27 May 2015); SPECTR (2000 to 27 May 2015); Bibliomap (1990 to 27 May 2015); RoRe, The Grey Literature (2002 to 27 May 2015); World Health Organization (WHO) International Clinical Trial Registry Platform (ICTRP), metaRegister of Controlled Trials (mRCT), and reference lists of articles up to 27 May 2015. We also contacted researchers and organizations in the field. Individually randomized controlled trials (RCTs) and cluster-RCTs that compared the effects of hand washing interventions on diarrhoea episodes in children and adults with no intervention. Three review authors independently assessed trial eligibility, extracted data, and assessed risk of bias. We stratified the analyses for child day-care centres or schools, community, and hospital-based settings. Where appropriate, incidence rate ratios (IRR) were pooled using the generic inverse variance method and random-effects model with 95% confidence intervals (CIs). We used the GRADE approach to assess the quality of evidence. We included 22 RCTs: 12 trials from child day-care centres or schools in mainly high-income countries (54,006 participants), nine community-based trials in LMICs (15,303 participants), and one hospital-based trial among people with acquired immune deficiency syndrome (AIDS) (148 participants).Hand washing promotion (education activities, sometimes with

  7. Characterization, Washing, Leaching, and Filtration of C-104 Sludge

    Energy Technology Data Exchange (ETDEWEB)

    KP Brooks; PR Bredt; GR Golcar; SA Hartley; LK Jagoda; KG Rappe; MW Urie

    2000-06-09

    continuously adding approximately 5 L of 0.01-M NaOH and then removing it through the filter as permeate. The purpose of this washing step with 0.01-MNaOH was to remove water-soluble components that might inhibit dissolution of salts during caustic leaching, while avoiding peptization of the solids that occurs at a pH below 12. After washing the sludge with dilute caustic, it was combined with 3-M caustic, and the slurry was leached in a stainless steel vessel at 85 C for 8 hours. This leaching was followed by two 0.01-M caustic washes, each conducted in a stainless steel vessel to dilute remaining analytes from the interstitial liquids. Each rinse was performed at 85 C for 8 hours. Permeate from each of these process steps was removed using the crossflow filter system. Samples of the permeate from each slurry-washing activity and all intermediate process steps were taken and analyzed for chemical and radiochemical constituents. The fraction of each component removed was calculated. Key results are presented in Table S.1.

  8. Study Effect of Salt Washing Process on Content and Iodium Stability of Salt

    Directory of Open Access Journals (Sweden)

    Nelson Saksono

    2010-10-01

    Full Text Available Effect of Salt Washing Process on Content and Iodium Stability of Salt. Salt washing process should increase the saltquality. It should clean the salt from sludge or clay and also reduce the impurity compound such as Mg, Ca and the reductor content. The objective of these reseach is to assess the effect of washing process on the content og hygroscopic impurities compound (Ca and Mg, and reductor content of salt. The research also investigate the water absorbing, pH, KIO3 content as function of time to obtain effect of washing process on KIO3 stability in salt. The experiment result shows that the lowest content of Mg and reductor compound 0.016 % wt and 2.65 ppm respectively which is reached at the fi ne salt washing process using 27 % wt brine. The analysis of water content indicates an increase the Ca and Mg content, causing an water absorbtion in salt , However the effect on pH the is not clear.

  9. A LARCH BIOREFINERY: INFLUENCE OF WASHING AND PS CHARGE ON PRE-EXTRACTION PSAQ PULPING

    Directory of Open Access Journals (Sweden)

    Hanna S. Hörhammer

    2012-06-01

    Full Text Available This study deals with a biorefinery concept based on larch wood. Wood chips of Siberian larch (Larix sibirica Lebed. were treated with water before pulping at the optimal pre-extraction (PE condition of 150 °C and 90 minutes. Through PE, about 12.4% of the wood mass is dissolved, mainly from the arabinogalactan hemicellulose component. Fermentation of the hemicellulose-rich larch extract with Bacillus coagulans resulted in consumption of all C6 and C5 sugars and produced lactic acid in high yield. PE before pulping resulted in lower (4 to 5% pulp yield than for control kraft pulps. However, the pulp yield loss may be reduced by addition of polysulfide (PS and anthraquinone (AQ. The present study focuses on the effect of the degree of washing of the extracted chips and that of the PS charge in PSAQ pulping on the final properties of the pulp. Three different levels of washing and three different PS charges were tested. The characteristics of the extract, wash water, pulp, and black liquor samples were determined. The amount of sugars in the combined stream of collected extract and wash water obtained by mild washing was 10.2% on o.d. wood.

  10. The contribution of housing renovation to children’s blood lead levels: a cohort study

    Science.gov (United States)

    2013-01-01

    Background Routine renovation of older housing is a risk factor for childhood lead poisoning, but the contribution to children’s blood lead levels is poorly defined for children with lower exposure levels. Methods We examined a prospective cohort of 276 children followed from 6 to 24 months of age. We conducted surveys of renovation activities and residential lead hazards and obtained blood lead level (B-Pb) every six months. We analyzed B-Pb in a repeated measures design using a mixed effects linear model. Results Parent reported interior renovation ranged from 11 to 25% of housing units at the four, 6-month periods. In multivariable analysis, children whose housing underwent interior renovation had a 12% higher mean B-Pb by two years of age compared with children whose housing units were not renovated (p children in non-renovated housing, children whose housing units underwent renovation in the prior month had a 17% higher mean B-Pb at two years of age, whereas children whose housing renovation occurred in the prior 2–6 months had an 8% higher mean B-Pb. We also found an association between higher paint lead loading, measured using an X-ray fluorescence (XRF) based paint lead index, and child B-Pb (p = 0.02); for every 10 mg/cm2 increase in paint lead loading index there was a 7.5% higher mean childhood B-Pb. Conclusions In an analysis of data collected before the recent changes to Environmental Protection Agency’s Lead, Renovation, Repair and Painting Rule, routine interior housing renovation was associated with a modest increase in children’s B-Pb. These results are important for the provision of clinical advice, for housing and public health professionals, and for policymakers. PMID:23981571

  11. Test installation for studying erosion-corrosion of metals for coal washing plants

    Energy Technology Data Exchange (ETDEWEB)

    Hoey, G. R.; Dingley, W.; Wiles, C. T.

    1979-02-15

    A test installation was constructed for investigating erosion-corrosion of metals by coal-water slurries. Erosion-corrosion tests of mild steel panels were conducted using slurries of alundum, quartz, washed coal and coal refuse. Wear rates were found to depend on type of abrasive, particle size and water conductivity and were reduced by cathodic protection and inhibitors. Cathodic protection of mild steel in coal slurries containing sulphate ion reduced wear by 90% and 86% for stationary and rotating panels, respectively. This study has demonstrated that the successful application of corrosion control techniques would reduce metal wastage in coal washing plants. The test installation is considered suitable for developing the techniques.

  12. Effects of lead mineralogy on soil washing enhanced by ferric salts as extracting and oxidizing agents.

    Science.gov (United States)

    Yoo, Jong-Chan; Park, Sang-Min; Yoon, Geun-Seok; Tsang, Daniel C W; Baek, Kitae

    2017-10-01

    In this study, we evaluated the feasibility of using ferric salts including FeCl 3 and Fe(NO 3 ) 3 as extracting and oxidizing agents for a soil washing process to remediate Pb-contaminated soils. We treated various Pb minerals including PbO, PbCO 3 , Pb 3 (CO 3 ) 2 (OH) 2 , PbSO 4 , PbS, and Pb 5 (PO 4 ) 3 (OH) using ferric salts, and compared our results with those obtained using common washing agents of HCl, HNO 3 , disodium-ethylenediaminetetra-acetic acid (Na 2 -EDTA), and citric acid. The use of 50 mM Fe(NO 3 ) 3 extracted significantly more Pb (above 96% extraction) from Pb minerals except PbSO 4 (below 55% extraction) compared to the other washing agents. In contrast, washing processes using FeCl 3 and HCl were not effective for extraction from Pb minerals because of PbCl 2 precipitation. Yet, the newly formed PbCl 2 could be dissolved by subsequent wash with distilled water under acidic conditions. When applying our washing method to remediate field-contaminated soil from a shooting range that had high concentrations of Pb 3 (CO 3 ) 2 (OH) 2 and PbCO 3 , we extracted more Pb (approximately 99% extraction) from the soil using 100 mM Fe(NO 3 ) 3 than other washing agents at the same process conditions. Our results show that ferric salts can be alternative washing agents for Pb-contaminated soils in view of their extracting and oxidizing abilities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Comparison of the laboratory standard washing using CIPAC washing agent and the domestic washing on three recommended types of long-lasting insecticidal mosquito nets.

    Science.gov (United States)

    Ouattara, Jean Pierre Nabléni; Louwagie, Johanna; Pigeon, Olivier; Spanoghe, Pieter

    2013-01-01

    One of the best ways to prevent malaria is the use of insecticide-treated bed nets. Manufacturers pursue easier, safer and more efficient nets. Hence, many studies on the efficacy and wash resistance using World Health Organization standards have been reported. The commonly used detergent is "Savon de Marseille", because it closely resembles actually used soaps. At the 54(th) Collaborative International Pesticides Analytical Council (CIPAC) Technical Meeting in 2010, it was suggested to replace it by a standardized "CIPAC washing agent". The aim of this study was to investigate the difference between a laboratory hand washing simulation using the CIPAC washing agent (method-1) and a domestic washing (method-2) on different bed nets, as well as the effect of the drying process on the release of active ingredient. Interceptor®, Permanet®2.0 and Netprotect® nets were used in three treatments, each repeated 20 times. The first treatment included method-1 washing and indoor drying. The second treatment included method-2 washing and indoor drying. The third treatment used method-2 washing and UV-drying. The residual insecticide contents were determined using gas chromatography. The washing procedure and the number of washes have a significant effect on the release of active ingredient. Statistically, the two washing methods have the same effect on removing the active ingredient from the Interceptor® and Permanet®2.0 net, but a significantly different influence on the Netprotect® nets. The drying process has no significant effect on the insecticide. Both washing procedures affected the amount of insecticide remaining on nets independently of the impregnation technology. The active ingredient decreases with the number of washing cycles following an exponential or logarithmic model for coated nets. The laboratory hand washing simulation had more impact on the decrease of active ingredient content of the Netprotect® nets. All net types seemed to be effectively

  14. Comparison of the laboratory standard washing using CIPAC washing agent and the domestic washing on three recommended types of long-lasting insecticidal mosquito nets.

    Directory of Open Access Journals (Sweden)

    Jean Pierre Nabléni Ouattara

    Full Text Available One of the best ways to prevent malaria is the use of insecticide-treated bed nets. Manufacturers pursue easier, safer and more efficient nets. Hence, many studies on the efficacy and wash resistance using World Health Organization standards have been reported. The commonly used detergent is "Savon de Marseille", because it closely resembles actually used soaps. At the 54(th Collaborative International Pesticides Analytical Council (CIPAC Technical Meeting in 2010, it was suggested to replace it by a standardized "CIPAC washing agent". The aim of this study was to investigate the difference between a laboratory hand washing simulation using the CIPAC washing agent (method-1 and a domestic washing (method-2 on different bed nets, as well as the effect of the drying process on the release of active ingredient.Interceptor®, Permanet®2.0 and Netprotect® nets were used in three treatments, each repeated 20 times. The first treatment included method-1 washing and indoor drying. The second treatment included method-2 washing and indoor drying. The third treatment used method-2 washing and UV-drying. The residual insecticide contents were determined using gas chromatography.The washing procedure and the number of washes have a significant effect on the release of active ingredient. Statistically, the two washing methods have the same effect on removing the active ingredient from the Interceptor® and Permanet®2.0 net, but a significantly different influence on the Netprotect® nets. The drying process has no significant effect on the insecticide.Both washing procedures affected the amount of insecticide remaining on nets independently of the impregnation technology. The active ingredient decreases with the number of washing cycles following an exponential or logarithmic model for coated nets. The laboratory hand washing simulation had more impact on the decrease of active ingredient content of the Netprotect® nets. All net types seemed to be

  15. Renewable energy and technological development; Energia renovable y desarrollo tecnologico

    Energy Technology Data Exchange (ETDEWEB)

    Covarrubias Ramos, Rogelio [Fideicomiso para el ahorro de energia, (Mexico)

    2007-06-15

    In this presentation is widely described the work carried out by the Trust Fund for Electrical Energy Savings (FIDE) with reference to renewable energy foster. In the first part, it is found the FIDE's mission, which is focused on achieving the efficient use of the energy. Then, there are quiet briefly described the processes -carried out by the FIDE- in favour of the groundbreaking technology that achieves to decrease the energy squandering. In addition, there are mentioned different means boosting the energy savings. Then, there are described the issues the energy system should change in order to improve the actual situation of many Mexicans. There are briefly mentioned not only the environmental but also the social benefits of the use of renewable energy; besides, there are given the necessary elements in order to make it possible. Then, there are explained why the use of renewable energy would be profitable. Finally, it is described the methodology that should be followed in case it is wanted to find sponsors up to 100% for a project related to improvement of the energy production. [Spanish] Esta presentacion describe ampliamente la labor que realiza el Fideicomiso para el ahorro de energia (FIDE) en relacion con el fomento de la energia renovable, asi como el desarrollo de tecnologias que refuercen el uso de este tipo de energia. En la primera parte, se encuentra la mision del FIDE, que se enfoca en lograr que el uso de la energia sea apropiado. Enseguida, de forma breve se describen los procesos que realiza el FIDE en favor de la tecnologia innovadora que haga decrecer el dispendio de energia. Luego, se explican las aspectos endebles del sistema energetico de Mexico. Se describen escuetamente los beneficios, no solo ambientales sino tambien sociales, del uso de energia renovable; ademas, se mencionan los elementos necesarios para que esto pueda lograrse. Mas adelante, se dan las razones por las que para Mexico seria rentable el uso de energia renovable

  16. Renewable energy and technological development; Energia renovable y desarrollo tecnologico

    Energy Technology Data Exchange (ETDEWEB)

    Covarrubias Ramos, Rogelio [Fideicomiso para el ahorro de energia, (Mexico)

    2007-06-15

    In this presentation is widely described the work carried out by the Trust Fund for Electrical Energy Savings (FIDE) with reference to renewable energy foster. In the first part, it is found the FIDE's mission, which is focused on achieving the efficient use of the energy. Then, there are quiet briefly described the processes -carried out by the FIDE- in favour of the groundbreaking technology that achieves to decrease the energy squandering. In addition, there are mentioned different means boosting the energy savings. Then, there are described the issues the energy system should change in order to improve the actual situation of many Mexicans. There are briefly mentioned not only the environmental but also the social benefits of the use of renewable energy; besides, there are given the necessary elements in order to make it possible. Then, there are explained why the use of renewable energy would be profitable. Finally, it is described the methodology that should be followed in case it is wanted to find sponsors up to 100% for a project related to improvement of the energy production. [Spanish] Esta presentacion describe ampliamente la labor que realiza el Fideicomiso para el ahorro de energia (FIDE) en relacion con el fomento de la energia renovable, asi como el desarrollo de tecnologias que refuercen el uso de este tipo de energia. En la primera parte, se encuentra la mision del FIDE, que se enfoca en lograr que el uso de la energia sea apropiado. Enseguida, de forma breve se describen los procesos que realiza el FIDE en favor de la tecnologia innovadora que haga decrecer el dispendio de energia. Luego, se explican las aspectos endebles del sistema energetico de Mexico. Se describen escuetamente los beneficios, no solo ambientales sino tambien sociales, del uso de energia renovable; ademas, se mencionan los elementos necesarios para que esto pueda lograrse. Mas adelante, se dan las razones por las que para Mexico seria rentable el uso de energia renovable

  17. Design of full scale debris washing system

    International Nuclear Information System (INIS)

    Taylor, M.L.; Dosani, M.A.; Wentz, J.A.; Patkar, A.N.; Barkley, N.P.

    1992-01-01

    Since 1987, IT Environmental Programs Inc. (ITEP, a subsidiary of International Technology Corporation) in conjunction with EPA/RREL in Cincinnati, Ohio, have been developing and conducting bench scale and pilot scale testing of a transportable debris washing system which can be used on-site for the decontamination of debris. During the initial phase of the debris decontamination project, a series of bench scale tests were performed in the laboratory to assess the ability of the system to remove contaminants from debris and to facilitate selection of the most efficient surfactant solution. Five nonionic, non-toxic, low foaming, surfactant solution (BG-5, MC-2000, LF-330, BB-100, and L-433) were selected for an experimental evaluation to determine their capacity to solubilize and remove contaminants from the surfaces of corroded steel places. The pieces of corroded steel were coated with a heavy grease mixture prepared in the laboratory and these pieces of debris were placed in a bench scale spray tank on a metal tray and subjected in a high-pressure spray for each surfactant solution for 15 minutes. At the end of the spray cycle, The tray was transferred to a second bench scale system, a high-turbulence wash tank, where the debris was washed for 30 minutes with the same surfactant solution as the used in the spray tank. After the was cycle was completed, the tray was removed from the wash tank and the debris was allowed to air-dry. Before and after treatment, surface-wipe samples were obtained from each of the six pieces of debris and were analyzed for oil and graese. Based on the results, BG-5 was selected as the solution best suited for cleaning grease-laden, metallic debris. 2 refs

  18. Suppression of deicing salt corrosion of weathering steel bridges by washing

    International Nuclear Information System (INIS)

    Hara, Shuichi; Miura, Masazumi; Uchiumi, Yasushi; Fujiwara, Toshiaki; Yamamoto, Masataka

    2005-01-01

    To elucidate the influences of deicing salts and high pressure (2-4 MPa) washing on the characteristics of the rust formed on weathering steel bridges, washing experiments have been carried out for three years. The rust was characterized by means of ion chromatography, X-ray diffraction and adsorption of N 2 . The rust thickness was measured, and also the rust weight per unit area of the steel surface was measured. It was found that water-soluble chloride accelerated the rate of corrosion because the rust particles grow by the chloride ions and micro-pore structure of the rust appeared by the chloride ions. Washing with water suppressed corrosion owing to the disappearance of chloride ions

  19. Hand washing practices amongst medical students in Port Harcourt ...

    African Journals Online (AJOL)

    Nigerian Health Journal ... Rates of hand washing are low world wide even amongst health care workers who are should know about its importance. The aim of ... The greatest motivation for hand washing was fear of contracting disease, whilst ...

  20. Fracture coatings in Topopah Spring Tuff along drill hole wash

    International Nuclear Information System (INIS)

    Carlos, B.A.; Chipera, S.J.; Bish, D.L.

    1994-01-01

    Fracture-lining minerals are being studied as part of site characterization to determine the suitability of Yucca Mountain, Nevada as a potential high level nuclear waste repository. Fracture coatings in the Paintbrush Group provide information on potential flow paths above the water table both toward and away from the potential repository and provide information on the distribution of fracture-lining minerals needed to model thermal effects of waste emplacement. Fracture coatings within the predominantly non-zeolitic Paintbrush Group vary both with depth and laterally across Yucca Mountain, whereas fracture coatings in tuffs below the Paintbrush Group are related to the mineralogy of the tuffs and follow a consistent pattern of distribution with predominantly quartz, calcite, and manganese oxides in the devitrified intervals and mordenite and clinoptilolite in the zeolitic intervals. The zeolites stellerite and heulandite are more abundant in fractures in the Topopah Spring Tuff in drill holes USW G-1 and UE-25 a number-sign l, located along Drill Hole Wash (at the northern end of Yucca Mountain) than in core from other parts of Yucca Mountain. Buesch et al. (2) present evidence for a complex fault system along Drill Hole Wash. To investigate the possibility that the abundant fracture-lining zeolites in USW G-1 and UE-25 a number-sign 1 are related to the Drill Hole Wash fault, the Topopah Spring Tuff was examined in drill cores from USW UZ-14, USW G-1, USW NRG-7/7a, and UE-25 a number-sign l

  1. Ceramic wash-coat for catalyst support

    Science.gov (United States)

    Kulkarni, Anand A.; Subramanian, Ramesh; Sabol, Stephen M.

    2012-08-14

    A wash-coat (16) for use as a support for an active catalyst species (18) and a catalytic combustor component (10) incorporating such wash-coat. The wash-coat is a solid solution of alumina or alumina-based material (Al.sub.2O.sub.3-0-3 wt % La.sub.2O.sub.3) and a further oxide exhibiting a coefficient of thermal expansion that is lower than that exhibited by alumina. The further oxide may be silicon dioxide (2-30 wt % SiO.sub.2), zirconia silicate (2-30 wt % ZrSiO.sub.4), neodymium oxide (0-4 wt %), titania (Al.sub.2O.sub.3-3-40% TiO.sub.2) or alumina-based magnesium aluminate spinel (Al.sub.2O.sub.3-25 wt % MgO) in various embodiments. The active catalyst species may be palladium and a second metal in a concentration of 10-50% of the concentration of the palladium.

  2. Washing scaling of GeneChip microarray expression

    Directory of Open Access Journals (Sweden)

    Krohn Knut

    2010-05-01

    Full Text Available Abstract Background Post-hybridization washing is an essential part of microarray experiments. Both the quality of the experimental washing protocol and adequate consideration of washing in intensity calibration ultimately affect the quality of the expression estimates extracted from the microarray intensities. Results We conducted experiments on GeneChip microarrays with altered protocols for washing, scanning and staining to study the probe-level intensity changes as a function of the number of washing cycles. For calibration and analysis of the intensity data we make use of the 'hook' method which allows intensity contributions due to non-specific and specific hybridization of perfect match (PM and mismatch (MM probes to be disentangled in a sequence specific manner. On average, washing according to the standard protocol removes about 90% of the non-specific background and about 30-50% and less than 10% of the specific targets from the MM and PM, respectively. Analysis of the washing kinetics shows that the signal-to-noise ratio doubles roughly every ten stringent washing cycles. Washing can be characterized by time-dependent rate constants which reflect the heterogeneous character of target binding to microarray probes. We propose an empirical washing function which estimates the survival of probe bound targets. It depends on the intensity contribution due to specific and non-specific hybridization per probe which can be estimated for each probe using existing methods. The washing function allows probe intensities to be calibrated for the effect of washing. On a relative scale, proper calibration for washing markedly increases expression measures, especially in the limit of small and large values. Conclusions Washing is among the factors which potentially distort expression measures. The proposed first-order correction method allows direct implementation in existing calibration algorithms for microarray data. We provide an experimental

  3. Design scenarios for renovation of sports complex: a case study

    Science.gov (United States)

    Nižetić, S.

    2018-02-01

    This paper elaborates design scenarios for a sports complex in Croatia from a technical and economic aspect. Different energy options are analysed and two are additionally addressed and discussed as the most viable ones. The possibilities of sports complex renovation are shown by properly choosing the appropriate energy concept and thus reducing the overall cost for produced thermal energy by around 33% and reducing the carbon dioxide emission by a factor of 1.8 in comparison with its present state. Finally, this study presents an example of good practice, where renewable energy solutions can be proposed and where it is possible to cover around 70-80% of overall yearly costs from achieved energy savings for the novel plant that is assumed to be financed through a bank loan.

  4. Defining Sustainability in Relation to the Renovation of Modern Housing

    DEFF Research Database (Denmark)

    Peters, Terri

    Summary This paper focuses on comparing practice-based and academic definitions and metrics of “sustainability” as they relate to the transformation of Modern housing in Denmark. Keywords:Sustainability, Renovation, Architecture, Denmark, Modern housing 1. Introduction to the Study Buildings......”. 2. Background to the Study and Study Context Despite the increasing focus on low energy buildings and sustainability, the definitions of key terms in these areas are unclear. This paper focuses on architectural approaches to sustainable building, rather than engineering or other ways of approaching...... process, and how successfully they were used. Data collected includes definitions of sustainability from outside of the profession, as well as in architectural literature. Definitions used in the context of architectural practice were also studied. The definitions from selected key texts were compared...

  5. Indoor climate quality after renovation for improved energy efficiency

    DEFF Research Database (Denmark)

    Gunnarsen, Lars Bo; Løck, Sebastian; Kolarik, Barbara

    2016-01-01

    The building sector is responsible for approximately 40 % of the Danish energy consumption. As every year less than 1 % of the building stock is rebuild after demolition of old buildings, improved energy efficiency of existing buildings are in focus. In the late seventies to mid-eighties unwise...... performance. The indoor quality classifications show minor improvements. By using design tools beyond the simple legal requirements, the rental dwelling marked is a far step ahead of most retrofitting of owner-occupied dwellings and houses. The fear of indoor climate degradation from retrofitted energy saving...... measures may be countered by the use of modern design tools and attention to inner moisture membranes and needs for renovation of ventilation systems....

  6. The Use of Reference Models in Business Process Renovation

    Directory of Open Access Journals (Sweden)

    Dejan Pajk

    2010-01-01

    Full Text Available Enterprise resource planning (ERP systems are often used by companies to automate and enhance their busi- ness processes. The capabilities of ERP systems can be described by best-practice reference models. The purpose of the article is to demonstrate the business process renovation approach with the use of reference models. Although the use of reference models brings many positive effects for business, they are still rarely used in Slovenian small and medium-sized compa- nies. The reasons for this may be found in the reference models themselves as well as in project implementation methodologies. In the article a reference model based on Microsoft Dynamics NAV is suggested. The reference model is designed using upgraded BPMN notation with additional business objects, which help to describe the models in more detail.

  7. Energy renovation of an old single-family house

    DEFF Research Database (Denmark)

    Overgaard, L.L.; Tommerup, Henrik M.; Svendsen, Svend

    2005-01-01

    After having identified a large potential for profitable energy renovation of the existing building stock, a demonstration project was carried out in practice. This paper deals with the methods and results from the demonstration project concerning a 161 m² poorly insulated single-family house built...... saving improvements carried out in the project are “easy to carry out” and cost-beneficial measures such as cavity wall insulation, loft insulation, insulation of walls under windows and a new second window-frame with energy-saving glass. The work was carried out by professional contractors at a total......). If a conservative way of financing the building work of 157,000 DKK is assumed, the first year’s cost equals DKK 8,500 and the house owner will gain a net saving the first year of DKK 7,500....

  8. CERN's PS Booster LLRF renovation : plans and initial beam tests

    CERN Document Server

    Angoletta, ME; Butterworth, A; Findlay, A; Leinonen, PM; Molendijk, JC; Pedersen, F; Sanchez-Quesada, J; Schokker, M

    2010-01-01

    In 2008 a project was started to renovate the CERN's PS Booster (PSB) low-level RF (LLRF). Required LLRF capabilities include frequency program, beam phase, radial and synchronization loops. The new LLRF will control the signals feeding the three RF cavities present in each ring; it will also shape the beam in a dual harmonic mode, operate a bunch splitting and create a longitudinal blow-up. The main benefits of this new LLRF are its full remote and cycle-to-cycle controllability, built-in observation capability and flexibility. The overall aim is to improve the robustness, maintainability and reliability of the PSB operation and to make it compatible with the injection from the future Linac4. This paper outlines the main characteristics of the software and hardware building blocks. Initial beam test results and hints on the main milestones and future work are also given.

  9. Effect of number and washing solutions on functional properties of surimi-like material from duck meat.

    Science.gov (United States)

    Ramadhan, Kurnia; Huda, Nurul; Ahmad, Ruzita

    2014-02-01

    Duck meat is less utilized than other meats in processed products because of limitations of its functional properties, including lower water holding capacity, emulsion stability, and higher cooking loss compared with chicken meat. These limitations could be improved using surimi technology, which consists of washing and concentrating myofibrillar protein. In this study, surimi-like materials were made from duck meat using two or three washings with different solutions (tap water, sodium chloride, sodium bicarbonate, and sodium phosphate buffer). Better improvement of the meat's functional properties was obtained with three washings versus two washings. Washing with tap water achieved the highest gel strength; moderate elevation of water holding capacity, pH, lightness, and whiteness; and left a small amount of fat. Washing with sodium bicarbonate solution generated the highest water holding capacity and pH and high lightness and whiteness values, but it resulted in the lowest gel strength. Processing duck meat into surimi-like material improves its functional properties, thereby making it possible to use duck meat in processed products.

  10. Performance of ceramic ultrafiltration and reverse osmosis membranes in treating car wash wastewater for reuse.

    Science.gov (United States)

    Moazzem, Shamima; Wills, Jamie; Fan, Linhua; Roddick, Felicity; Jegatheesan, Veeriah

    2018-03-01

    Reusing treated effluents in industries is a great option to conserve freshwater resources. For example, car wash centres all over Australia are estimated to use 17.5 billion litres of water and discharge it as wastewater and spend $75 million a year for both purchasing fresh water and for treating and/or discharging the wastewater. Therefore, it is important to develop simple but reliable systems that can help to treat and reuse car wash wastewater. Significant savings could also be associated with the implementation of such systems. This study evaluates the performance of granular and membrane filtration systems with coagulation/flocculation and sedimentation in treating car wash wastewater for the purpose of reuse. Overall, 99.9% of turbidity, 100% of suspended solids and 96% of COD were removed from the car wash wastewater after treating by coagulation, flocculation, sedimentation, sand filtration, ceramic ultrafiltration and reverse osmosis and the treated water meets the standards required for class A recycled water in Australia and standards imposed in Belgium and China. The treated water can be reused. However, optimisation is required to reduce the sludge produced by this system.

  11. Challenges and Opportunities for Mainstreaming Climate Change Adaptation into WaSH Development Planning in Ghana.

    Science.gov (United States)

    Alhassan, Salley; Hadwen, Wade L

    2017-07-10

    Climate change threatens water, sanitation and hygiene (WaSH) facilities and services, as these are intimately linked to the water cycle and are vulnerable to changes in the quantity and quality of available water resources. Floods and droughts, which pollute and reduce water delivery respectively, have now become a perennial issue to deal with in the northern regions of Ghana. This study aimed to assess the degree to which climate change adaptation measures are mainstreamed into the water, sanitation and hygiene (WaSH) development planning process in Ghana. Stakeholders from government and non-government agencies were interviewed to gain perspectives on the threat of climate change, the inclusion of climate change in WaSH planning and the barriers preventing mainstreaming. Despite awareness of climate change, adaptation measures have not been considered, and the immediate WaSH needs remain the priority. Overall, stakeholders felt the adaptive capacity of the Municipality was low and that mainstreaming has not yet occurred. Despite the lack of progress, there are great opportunities for mainstreaming climate change adaptation into planning through increasing awareness and capacity, legislative and institutional changes and the development of participatory systems to provide early warning systems and disaster risk analyses that will inform future planning.

  12. Challenges and Opportunities for Mainstreaming Climate Change Adaptation into WaSH Development Planning in Ghana

    Directory of Open Access Journals (Sweden)

    Salley Alhassan

    2017-07-01

    Full Text Available Climate change threatens water, sanitation and hygiene (WaSH facilities and services, as these are intimately linked to the water cycle and are vulnerable to changes in the quantity and quality of available water resources. Floods and droughts, which pollute and reduce water delivery respectively, have now become a perennial issue to deal with in the northern regions of Ghana. This study aimed to assess the degree to which climate change adaptation measures are mainstreamed into the water, sanitation and hygiene (WaSH development planning process in Ghana. Stakeholders from government and non-government agencies were interviewed to gain perspectives on the threat of climate change, the inclusion of climate change in WaSH planning and the barriers preventing mainstreaming. Despite awareness of climate change, adaptation measures have not been considered, and the immediate WaSH needs remain the priority. Overall, stakeholders felt the adaptive capacity of the Municipality was low and that mainstreaming has not yet occurred. Despite the lack of progress, there are great opportunities for mainstreaming climate change adaptation into planning through increasing awareness and capacity, legislative and institutional changes and the development of participatory systems to provide early warning systems and disaster risk analyses that will inform future planning.

  13. Energy savings from housing: Ineffective renovation subsidies vs efficient demolition and reconstruction incentives

    International Nuclear Information System (INIS)

    Dubois, Maarten; Allacker, Karen

    2015-01-01

    Energy savings in the housing sector are key to reduce global greenhouse gas emissions. Policies to incentivize energy savings are however disparate between countries. Taking into account environmental aspects and consumer surplus, the paper uses a stylized economic model to assess the effectiveness and efficiency of three economic instruments: subsidies for renovation, subsidies for demolition and reconstruction projects and subsidies for building new houses on virgin land. The assessment also relates to differentiated value added taxes and other financial incentives such as green loans. In a counter-intuitive way, the model highlights that subsidies for renovations with minor energy gains worsen the overall energy consumption of housing due to the inducement of lock-ins with energy inefficient houses. Structural changes are needed in the use of policy instruments. First, commonly applied support schemes for renovations with minor energy savings should be abolished. Second, scarce public resources should incentivize deep renovation and demolition and reconstruction. Finally, taxes should apply on the use of virgin land to persuade households with a high willingness to pay for a new house, to invest in demolition and reconstruction. - Highlights: • Renovation subsidies worsen overall energy consumption of housing. • Renovation induces a lock-in with energy inefficient houses. • Renovation subsidies should be abolished or structurally reformed. • Policy should incentivize demolition and reconstruction projects. • Building on virgin land should be taxed.

  14. A hybrid decision support system for sustainable office building renovation and energy performance improvement

    Energy Technology Data Exchange (ETDEWEB)

    Juan, Yi-Kai [Department of Architecture, National Taiwan University of Science and Technology (NTUST) (China); Center for Sustainable Development and Global Competitiveness, Stanford University (United States); Gao, Peng [Department of Traffic and Transportation Engineering, Tongji University (China); Wang, Jie [Center for Sustainable Development and Global Competitiveness, Stanford University (United States)

    2010-03-15

    Energy consumption of buildings accounts for around 20-40% of all energy consumed in advanced countries. Over the last decade, more and more global organizations are investing significant resources to create sustainably built environments, emphasizing sustainable building renovation processes to reduce energy consumption and carbon dioxide emissions. This study develops an integrated decision support system to assess existing office building conditions and to recommend an optimal set of sustainable renovation actions, considering trade-offs between renovation cost, improved building quality, and environmental impacts. A hybrid approach that combines A* graph search algorithm with genetic algorithms (GA) is used to analyze all possible renovation actions and their trade-offs to develop the optimal solution. A two-stage system validation is performed to demonstrate the practical application of the hybrid approach: zero-one goal programming (ZOGP) and genetic algorithms are adopted to validate the effectiveness of the algorithm. A real-world renovation project is introduced to validate differences in energy performance projected for the renovation solution suggested by the system. The results reveal that the proposed hybrid system is more computationally effective than either ZOGP or GA alone. The system's suggested renovation actions would provide substantial energy performance improvements to the real project if implemented. (author)

  15. Remediation of cadmium contamination in paddy soils by washing with chemicals: Selection of washing chemicals

    International Nuclear Information System (INIS)

    Makino, Tomoyuki; Sugahara, Kazuo; Sakurai, Yasuhiro; Takano, Hiroyuki; Kamiya, Takashi; Sasaki, Kouta; Itou, Tadashi; Sekiya, Naoki

    2006-01-01

    The efficiencies of neutral salts, strong acids, and chelates were tested for extracting cadmium (Cd) from three paddy soils. The higher the selectivity of the cations of the added neutral salts toward soil adsorption sites, the lower the pH in the extracts and the more soil Cd could be extracted. In addition, soil carbon and nitrogen contents and mineral composition were closely associated with the amount of Cd extracted. Calcium chloride and iron(III) chloride were selected as wash chemicals to restore Cd-contaminated paddy soils in situ. Washing with calcium chloride led to the formation of Cd chloride complexes, enhancing Cd extraction from the soils. The washing also substantially decreased soil levels of exchangeable and acid-soluble Cd, which are the major forms of bioavailable Cd for rice (Oryza sativa L.). The optimum conditions for in situ soil washing were also determined for calcium chloride. - Calcium chloride and iron(III) chloride were useful for the in situ washing of Cd-contaminated paddy soils

  16. We forgot half of the population! The significance of gender in Danish energy renovation projects

    DEFF Research Database (Denmark)

    Tjørring, Lise

    2016-01-01

    that the way people live their everyday lives plays a crucial role in understanding why they choose whether to perform an energy renovation. This study is based on an anthropological investigation of ten Danish families and their decision-making process while receiving free energy advice, which, in many cases......, ended as an energy renovation project in the home. During the study, gender emerged as a significant factor in two ways. First, energy renovations were perceived differently by men and women as a consequence of their different everyday practices. Second, there was a cultural norm about the division...... that contains different gender practices and cultural influences....

  17. Renovation of the sealing planes of WWER-400 reactors pressure vessel

    International Nuclear Information System (INIS)

    Jablonicky, P.; Pilat, P.

    2007-01-01

    An article describes technical solution for renovation of the sealing planes of WWER-440 reactor's pressure vessel. Four nickel sealing rings placed in four concentric grooves are providing hermetic sealing between the vessel and the lid of this type of the reactor. Impeccable seal of the reactor's pressure vessel, where the fission reaction takes place, represents a basic security factor for safe electric energy production. Principle of renovation of the reactor's pressure vessel and lid sealing planes is based on mechanical enlargement of defective grooves and following cladding of the new material by TIG welding. Final step for renovation includes machining of new grooves according to geometrical and surface quality requirements (Authors)

  18. Energy Use and Indoor Climate in Two Schools Before and After Deep Energy Renovation

    DEFF Research Database (Denmark)

    Rose, Jørgen; Thomsen, Kirsten Engelund; Mørck, Ove

    2013-01-01

    . The 7 buildings are being energy renovated and monitored with support from the EU-CONCERTO initiative as part of the project “Cost-effective Low-energy Advanced Sustainable So1utions – Class1”. The buildings are very different and therefore the energy renovations to take place will also vary from...... insulation of piping and improved control (Building Energy Management Systems – BEMS). This paper presents preliminary results of analysis and monitoring of energy use and indoor climate in the two public schools before and after deep energy renovation....

  19. Effect of energy renovation on indoor air quality in multifamily residential buildings in Slovakia

    DEFF Research Database (Denmark)

    Földváry, Veronika; Bekö, Gabriel; Langer, Sarka

    2017-01-01

    efficiency of these buildings rarely consider their impact on the indoor air quality (IAQ). The objective of the present study was to evaluate the impact of simple energy renovation on IAQ, air exchange rates (AER) and occupant satisfaction in Slovak residential buildings. Three pairs of identical naturally...... of nitrogen dioxide (NO2), formaldehyde and total and individual volatile organic compounds (VOC) were also measured. CO2 concentrations were significantly higher and AERs were lower in the renovated buildings. Formaldehyde concentrations increased after renovation and were positively correlated with CO2...

  20. Use of pulsed neutron logging to evaluate perforation washing

    International Nuclear Information System (INIS)

    Dimon, C.A.

    1986-01-01

    This invention relates to the use of pulsed neutron logging techniques before and after perforation washing operations are performed to evaluate the degree of success of the perforation washing operations. Well logging operations of a type designed to respond to the difference between a formation immediately behind the well sheath and voids in the formation are performed both before and after the perforation washing operation. differences between the two resulting logs are then indicative of voids created by perforation washing. In a preferred embodiment, pulsed neutron logging is used as the logging technique, while a weighted brine having a high absorption cross section to pulsed neutrons is used as the perforation washing fluid

  1. Hydrologic impacts of climate change and urbanization in Las Vegas Wash Watershed, Nevada

    Science.gov (United States)

    In this study, a cell-based model for the Las Vegas Wash (LVW) Watershed in Clark County, Nevada, was developed by combining the traditional hydrologic modeling methods (Thornthwaite’s water balance model and the Soil Conservation Survey’s Curve Number method) with the pixel-base...

  2. 78 FR 28577 - Notification of Proposed Production Activity: Whirlpool Corporation Subzone 8I; (Washing Machines...

    Science.gov (United States)

    2013-05-15

    ... machine parts to the list of approved finished products and would also add imported components to the...; refrigeration parts; dishwashing machine parts; drying machine parts; water inlet valves; AC/DC fan motors; AC... Activity: Whirlpool Corporation Subzone 8I; (Washing Machines): Clyde and Green Springs, Ohio Whirlpool...

  3. Development of technology for washed minced fish production from low-profit objects of fishing in the Volga-Caspian Basin

    Directory of Open Access Journals (Sweden)

    Mukatova M. D.

    2016-09-01

    Full Text Available The objects of the study are as follows: rudd and goldfish, samples of food minced made of them without washing, after single and double washings. To study the organoleptic and physico-chemical parameters the conventional methods of the fishing industry have been used. At the LLC "Astrakhan fisheries" two experimental batches of minced rudd and goldfish with double washing by water using a food additive "Omfresh plus" have been made in the amount of 1.0 % by weight of the meat. The yield of washed minced food from rudd is 41.4 %, from silver carp – 41.0 %. Some decrease in water content, water-holding capacity and formalin-titratable nitrogen in minced fish after each washing step has been established. Studying the organoleptic characteristics has shown that the frozen minced briquettes are cuboids, have clean surface with the presence of minor irregularities, colour – light gray, dense texture. On physical and chemical parameters the food washed mince correspond to GOST R 55505–2013 "Frozen food fish forcemeat. Specifications". Water content is 79–82 %, sodium chloride – 0,17–0,35 %, and water-holding capacity – at over 50 %. The proven technology of manufacturing washed minced from goldfish and rudd can be put into production for the purpose of deep processing of unprofitable species of the Volga-Caspian Basin and getting washed minced food and culinary products based on it.

  4. Effects of process parameters on ozone washing for denim using 3/sup 3/ factorial design

    International Nuclear Information System (INIS)

    Asim, F.; Mahmood, M.

    2017-01-01

    Denim garment is getting popular day by day. It is highly demandable because of its versatility, comfort and durability. Different techniques of denim washing increase this demand drastically. Denim washing is the process to enhance the appearance of a garment. This enhanced appearance may be the aged look, faded look, greyer cast, or any other shade setting or resin application. The two most advanced washing techniques are; ozone wash and laser wash. The effects of ozone on environment as well as on the garment are significant and cannot be neglected because number of benefits achieved such as time saving, less energy consumption, chemical, labour cost reduction, less discharge of water and chemicals. Therefore, effects of process parameters on ozone washing for denim fabric have been investigated in this research work using three level factorial design. 33 factorial design has been designed and conducted to investigate the effect of gas concentration, time and speed on the response variables namely; Shrinkage, Tensile and Tear strength of ozone washing. The influence of individual factors and their interactions has been critically examined using software Design Expert 8.0. Prior to the analysis of variance model accuracy has been examined through various residuals plots. The study of residuals plots shown that the residuals are normally distributed and significant evidence of possible outliers was not found. So the model can be used to predicted results with 95% confidence interval. The results from the experiment suggest that two out of three factors were significant, which are speed and time that influences mainly on the tear strength of the denim garment. (author)

  5. Solar Water Heating with Low-Cost Plastic Systems (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2012-01-01

    Newly developed solar water heating technology can help Federal agencies cost effectively meet the EISA requirements for solar water heating in new construction and major renovations. This document provides design considerations, application, economics, and maintenance information and resources.

  6. Social determinants of good hand-washing practice (GHP) among adolescents in a rural Indian community.

    Science.gov (United States)

    Dobe, Madhumita; Mandal, Ram Narayan; Jha, Ayan

    2013-01-01

    A cross-sectional study was conducted in 5 randomly selected villages to assess prevalence of good hand-washing practice (GHP) among adolescents, and describe the social determinants. The prevalence of adolescent GHP was 32.1% (95% CI = 27.1, 37.1). Logistic regression established 5 significant positive predictors-maternal GHP, presence of sanitary latrine, availability of soap at hand-washing locations, in-house water supply, and higher per capita income. Our research provides a scope for better understanding of the socioeconomic determinants of GHP in a rural Indian setting, and may find implications in the Total Sanitation Campaign launched by Government of India.

  7. Decision-making in the Pre-design Stage of Sustainable Building Renovation Projects

    DEFF Research Database (Denmark)

    Gade, Anne Nørkjær; Jensen, Rasmus Lund; Larsen, Tine Steen

    2017-01-01

    There is a great potential in renovating our existing building stock, in terms of improving environmental, economic and social qualities. Meeting the increasing performance requirements for sustainable construction entails an increasing level of complexity in the design process of both new...... buildings and renovation projects. Decision support tools are one solution that can help the building owner manage this complexity. This study investigates the current decision-making processes among Danish professional building owners, in order to propose a conceptual framework for future decision support...... tools for sustainable renovation. Design Science Research Methodology has been used as the main methodological framework. Current practices for setting goals for sustainability, determining the current state of the buildings and prioritizing which buildings to renovate within a building portfolio, have...

  8. 76 FR 47917 - Lead; Clearance and Clearance Testing Requirements for the Renovation, Repair, and Painting Program

    Science.gov (United States)

    2011-08-05

    ... available, e.g., Confidential Business Information (CBI) or other information whose disclosure is restricted... to window replacement to complete kitchen and bath renovations to building additions and everything...

  9. The University of Michigan, Kellogg Building Expansion & Renovation, Ann Arbor, Michigan.

    Science.gov (United States)

    Design Cost Data, 2001

    2001-01-01

    Presents design, construction, and cost data for the University of Michigan's Kellogg Building expansion and renovation project. A list of project manufacturers and suppliers is provided along with four photographs and four floor plans. (GR)

  10. Business models for full service energy renovation of single-family houses in Nordic countries

    DEFF Research Database (Denmark)

    Mahapatra, Krushna; Gustavsson, Leif; Haavik, Trond

    2013-01-01

    the similarities are on how the service is provided. Even though there is strong business potential for one-stop-shop energy renovation concept, still it has been somewhat difficult to start or run such a business. Various options to overcome the hindrances to promote energy efficient renovation of detached houses...... markets are dominated by handicraft-based individual solutions. In this paper we have analyzed the opportunities for implementation of one-stop-shop business models where an overall contractor offers full-service renovation packages including consulting, independent energy audit, renovation work, follow......-up (independent quality control and commissioning) and financing. A comparative assessment of emerging business models in the Nordic countries shows that different types of actors can provide such a service. Financing is included in some models. There are differences in how customers are contacted, while...

  11. Architects and Librarians under Pressure: Dialoguing about Renovation of a Library in a Constrained Environment

    Directory of Open Access Journals (Sweden)

    André Lohisse

    2008-09-01

    Full Text Available A librarian and an architect conduct the essential dialogue involved in renovating an academic library in Paris, comparing architectural concerns with the exigencies of public use, and juxtaposing technical requirements with the functional organisation of the library.

  12. Washing and Caustic Leaching of Hanford Tank Sludge: Results of FY 1998 Studies

    Energy Technology Data Exchange (ETDEWEB)

    GJ Lumetta; BM Rapko; J Liu; DJ Temer; RD Hunt

    1998-12-11

    Sludge washing and parametric caustic leaching tests were performed on sludge samples tiom five Hanford tanks: B-101, BX-1 10, BX-112, C-102, and S-101. These studies examined the effects of both dilute hydroxide washing and caustic leaching on the composition of the residual sludge solids. ` Dilute hydroxide washing removed from <1 to 25% of the Al, -20 to 45% of the Cr, -25 to 97% of the P, and 63 to 99% of the Na from the Hdord tank sludge samples examined. The partial removal of these elements was likely due to the presence of water-soluble sodium salts of aluminate, chromate, hydroxide, nitrate, nitrite, and phosphate, either in the interstitial liquid or as dried salts.

  13. Electroless copper plating on 3-mercaptopropyltriethoxysilane modified PET fabric challenged by ultrasonic washing

    International Nuclear Information System (INIS)

    Lu Yinxiang

    2009-01-01

    Electroless deposition of Cu on poly(ethylene terephthalate) (PET) fabric modified with 3-mercaptopropyltriethoxysilane was investigated. Morphology, composition, structure, thermal decomposing behavior of copper coating PET fabric after ultrasonic washing in water for 1 h were characterized by scanning electron microscopy (SEM), energy dispersive X-ray (EDX) analysis, X-ray photoelectron spectroscopy (XPS), Raman spectrometer, X-ray diffraction (XRD), and thermogravimetric analysis (TG), respectively. Copper plating on modified fabric has good adherence stability and high electric conductivity before and after ultrasonic washing, while copper coating fabric without modification is easily destroyed during the washing process, which leads to the textile changing from conductor to dielectric. As the copper weight on the treated fabric is 28 g/m 2 , the shielding effectiveness (SE) is more than 54 dB at frequency ranging from 0.01 MHz to 18 GHz.

  14. Removal of Pb, Zn, and Cd from contaminated soil by new washing agent from plant material.

    Science.gov (United States)

    Cao, Yaru; Zhang, Shirong; Wang, Guiyin; Huang, Qinling; Li, Ting; Xu, Xiaoxun

    2017-03-01

    Soil washing is an effective approach to remove soil heavy metals, and the washing agent is generally regarded as one of the primary factors in the process, but there is still a lack of efficient and eco-friendly agents for this technique. Here, we showed that four plant washing agents-from water extracts of Coriaria nepalensis (CN), Clematis brevicaudata (CB), Pistacia weinmannifolia (PW), and Ricinus communis (RC)-could be feasible agents for the removal of soil lead (Pb), zinc (Zn), and cadmium (Cd). The metal removal efficiencies of the agents increased with their concentrations from 20 to 80 g L -1 , decreased with the increasing solution pH, and presented different trends with the reaction time increasing. CN among the four agents had the highest removal efficiencies of soil Pb (62.02%) and Zn (29.18%) but owned the relatively low Cd removal efficiencies (21.59%). The Fourier transform infrared spectroscopy showed that the abilities of plant washing agents for the removal of soil heavy metals may result from bioactive substances with specific functional groups such as -COOH, -NH 2 , and -OH. Our study provided CN as the best washing agents for the remediation of contaminated soil by heavy metals.

  15. Wastewater Treatment Model in Washing Stations for Vehicles Transporting Dangerous Goods

    Directory of Open Access Journals (Sweden)

    Robert Muha

    2004-09-01

    Full Text Available Car washing is a task performed by every passenger carowner more or less frequently, mainly to achieve a finer appearanceof the vehicle rather than for the need for cleanness.In the transport business, the owner's concern is to presentclean and orderly vehicles on the road as a relevant external elementof order, implying good corporate image to customers. Onthe other hand, in dangerous goods transportation there areother reasons requiring special technology of washing, applicableto the transport means used, depending on the change oftype of goods in carriage, the preliminary preparation of a vehicleto load the cargo, or to undergo maintenance.Water applied in the technology of washing collects the residueof goods carried in the vehicle and is polluted to such an extentthat it cannot be discharged into sewers - nor directly into awatercourse - without previous treatment.The paper presents a solution model and a sequence oftechnological procedures involved in an efficient treatment ofthe polluted wastewater in tank wash stations, in which mostlyvehicles carrying ADR goods are washed.

  16. Evaluation of cleaning methods applied in home environments after renovation and remodeling activities

    International Nuclear Information System (INIS)

    Yiin, L.-M.; Lu, S.-E.; Sannoh, Sulaiman; Lim, B.S.; Rhoads, G.G.

    2004-01-01

    We conducted a cleaning trial in 40 northern New Jersey homes where home renovation and remodeling (R and R) activities were undertaken. Two cleaning protocols were used in the study: a specific method recommended by the US Department of Housing and Urban Development (HUD), in the 1995 'Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing', using a high-efficiency particulate air (HEPA)-filtered vacuum cleaner and a tri-sodium phosphate solution (TSP); and an alternative method using a household vacuum cleaner and a household detergent. Eligible homes were built before the 1970s with potential lead-based paint and had recent R and R activities without thorough cleaning. The two cleaning protocols were randomly assigned to the participants' homes and followed the HUD-recommended three-step procedure: vacuuming, wet washing, and repeat vacuuming. Wipe sampling was conducted on floor surfaces or windowsills before and after cleaning to evaluate the efficacy. All floor and windowsill data indicated that both methods (TSP/HEPA and non-TSP/non-HEPA) were effective in reducing lead loading on the surfaces (P<0.001). When cleaning was applied to surfaces with initial lead loading above the clearance standards, the reductions were even greater, above 95% for either cleaning method. The mixed-effect model analysis showed no significant difference between the two methods. Baseline lead loading was found to be associated with lead loading reduction significantly on floors (P<0.001) and marginally on windowsills (P=0.077). Such relations were different between the two cleaning methods significantly on floors (P<0.001) and marginally on windowsills (P=0.066), with the TSP/HEPA method being favored for higher baseline levels and the non-TSP/non-HEPA method for lower baseline levels. For the 10 homes with lead abatement, almost all post-cleaning lead loadings were below the standards using either cleaning method. Based on our results, we recommend that

  17. Sustainable covers for uranium mill tailings, USA: alternative design, performance, and renovation - 16369

    International Nuclear Information System (INIS)

    Waugh, William J.; Benson, Craig H.; Albright, William H.

    2009-01-01

    The U.S. Department of Energy Office of Legacy Management is investigating alternatives to conventional cover designs for uranium mill tailings. A cover constructed in 2000 near Monticello, Utah, USA, was a redundant design with a conventional low-conductivity composite cover overlain with an alternative cover designed to mimic the natural soil water balance as measured in nearby undisturbed native soils and vegetation. To limit percolation, the alternative cover design relies on a 160-cm layer of sandy clay loam soil overlying a 40- cm sand capillary barrier for water storage, and a planting of native sagebrush steppe vegetation to seasonally release soil water through evapotranspiration (ET). Water balance monitoring within a 3.0-ha drainage lysimeter, embedded in the cover during construction, provided convincing evidence that the cover has performed well over a 9-year period (2000- 2009). The total cumulative percolation, 4.8 mm (approximately 0.5 mm yr -1 ), satisfied a regulatory goal of -1 . Most percolation can be attributed to the very wet winter and spring of 2004-2005, when soil water content exceeded the storage capacity of the cover. Diversity, percent cover, and leaf area of vegetation increased over the monitoring period. Field and laboratory evaluations several years after construction show that soil structural development, changes in soil hydraulic properties, and development of vegetation patterns have not adversely impacted cover performance. A new test facility was constructed in 2008 near Grand Junction, Colorado, USA, to evaluate low-cost methods for renovating or transforming conventional covers into more sustainable ET covers. (authors)

  18. Leveraging Limited Scope for Maximum Benefit in Occupied Renovation of Uninsulated Cold Climate Multifamily Housing

    Energy Technology Data Exchange (ETDEWEB)

    Neuhauser, K. [Building Science Corporation (BSC), Somer, MA (United States); Bergey, D. [Building Science Corporation (BSC), Somer, MA (United States); Osser, R. [Building Science Corporation (BSC), Somer, MA (United States)

    2012-03-01

    This project examines a large-scale renovation project within a 500 unit, 1960's era subsidized urban housing community. This research focuses on the airflow control and window replacement measures implemented as part of the renovations to the low-rise apartment buildings. The window replacement reduced the nominal conductive loss of the apartment enclosure by approximately 15%; air sealing measures reduced measured air leakage by approximately 40% on average.

  19. Aspinall Courthouse: GSA's Historic Preservation and Net-Zero Renovation Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Chang, R.; Hayter, S.; Hotchkiss, E.; Pless, S.; Sielcken, J.; Smith-Larney, C.

    2014-10-01

    The federal government is mandated with improving efficiency of buildings, incorporating renewable energy, and achieving net-zero energy operations where possible. These challenges led GSA to consider aligning historic preservation renovations with net-zero energy goals. The Wayne N. Aspinall Federal Building and U.S. Courthouse (Aspinall Courthouse), in Grand Junction, Colorado, is an example of a renovation project that aimed to accomplish both historic preservation and net-zero energy goals.

  20. Cost-optimal energy performance renovation measures of educational buildings in cold climate

    International Nuclear Information System (INIS)

    Niemelä, Tuomo; Kosonen, Risto; Jokisalo, Juha

    2016-01-01

    Highlights: • The proposed national nZEB target can be cost-effectively achieved in renovations. • Energy saving potential of HVAC systems is significant compared to the building envelope. • Modern renewable energy production technologies are cost-efficient and recommendable. • Improving the indoor climate conditions in deep renovations is recommendable. • Simulation-based optimization method is efficient in building performance analyzes. - Abstract: The paper discusses cost-efficient energy performance renovation measures for typical educational buildings built in the 1960s and 1970s in cold climate regions. The study analyzes the impact of different energy renovation measures on the energy efficiency and economic viability in a Finnish case study educational building located in Lappeenranta University of Technology (LUT) campus area. The main objective of the study was to determine the cost-optimal energy performance renovation measures to meet the proposed national nearly zero-energy building (nZEB) requirements, which are defined according to the primary energy consumption of buildings. The main research method of the study was simulation-based optimization (SBO) analysis, which was used to determine the cost-optimal renovation solutions. The results of the study indicate that the minimum national energy performance requirement of new educational buildings (E_p_r_i_m_a_r_y ⩽ 170 kWh/(m"2,a)) can be cost-effectively achieved in deep renovations of educational buildings. In addition, the proposed national nZEB-targets are also well achievable, while improving the indoor climate (thermal comfort and indoor air quality) conditions significantly at the same time. Cost-effective solutions included renovation of the original ventilation system, a ground source heat pump system with relatively small dimensioning power output, new energy efficient windows and a relatively large area of PV-panels for solar-based electricity production. The results and

  1. Business models for full service energy renovation of single-family houses in Nordic countries

    International Nuclear Information System (INIS)

    Mahapatra, Krushna; Gustavsson, Leif; Haavik, Trond; Aabrekk, Synnøve; Svendsen, Svend; Vanhoutteghem, Lies; Paiho, Satu; Ala-Juusela, Mia

    2013-01-01

    Highlights: ► In the Nordic countries there is significant primary energy saving potential in single-family houses from 1970s. ► There are several behavioral, economical and market related hindrances to adoption of energy efficiency measures. ► One-stop-shop business models to offer full service energy renovation packages are slowly emerging. ► Marketing strategies and policy measures are required to promote full service energy renovation of single-family house. - Abstract: In Nordic countries significant primary energy saving potential exists in houses built before 1980. These old houses need to be renovated, which provides an opportunity for implementation of energy efficiency measures. However, there are several economic and market hindrances and the renovation markets are dominated by handicraft-based individual solutions. In this paper we have analyzed the opportunities for implementation of one-stop-shop business models where an overall contractor offers full-service renovation packages including consulting, independent energy audit, renovation work, follow-up (independent quality control and commissioning) and financing. A comparative assessment of emerging business models in the Nordic countries shows that different types of actors can provide such a service. Financing is included in some models. There are differences in how customers are contacted, while the similarities are on how the service is provided. Even though there is strong business potential for one-stop-shop energy renovation concept, still it has been somewhat difficult to start or run such a business. Various options to overcome the hindrances to promote energy efficient renovation of detached houses are discussed

  2. Anaerobic digestion of waste waters after washing olives used for oil production: in fluence of harvest time on the kinetics of the process. Digestion anaerobia de las aguas de lavado de aceitunas de almazara: influencia del periodo de recoleccion sobre la cinetica del proceso

    Energy Technology Data Exchange (ETDEWEB)

    Borja-Padilla, R.; Alba-Mendoza, J.; Hidalgo-Casado, F.

    1994-01-01

    A kinetic study was carried out of anaerobic digestion of waste waters after washing olives used for oil production, collected at three different harvest times (December 1992, January and February 1993). A 1-litre mixed batch bioreactor operated at 35 degree centigree and containing a sepiolite-immobilized biomass was used. Assuming that the overall anaerobic digestion process conforms to a first-order kinetics, experimental data pairs, namely methane volume yield (G) and time (t), fit Roediger's equation, from which the rate coefficient values, k[sub o], were determined in each of the situations studied. The rate coefficient considerably decreased with the harvest time, over the substrate concentration range studied (0.5-2.5 g COD/1). The average values obtained were [sub 1.67],[sub 1.13] and [sub 0.75] days for the waste waters corresponding to the three harvest times considered. Also, the methanogenic activity decreased with the ripening of the olives; the observed differences increased when the substrate concentration in the digester increased. The coefficients of methane yield, Yp ranged between 0.263 (first harvest time) and 0.298 I CH[sub 4]/g COD removed (third harvest time). The elimination of COD exceeded 64% in all cases. (Author) 13 refs.

  3. Effectiveness of hand washing on the removal of iron oxide nanoparticles from human skin ex vivo.

    Science.gov (United States)

    Lewinski, Nastassja A; Berthet, Aurélie; Maurizi, Lionel; Eisenbeis, Antoine; Hopf, Nancy B

    2017-08-01

    In this study, the effectiveness of washing with soap and water in removing nanoparticles from exposed skin was investigated. Dry, nanoscale hematite (α-Fe 2 O 3 ) or maghemite (γ-Fe 2 O 3 ) powder, with primary particle diameters between 20-30 nm, were applied to two samples each of fresh and frozen ex vivo human skin in two independent experiments. The permeation of nanoparticles through skin, and the removal of nanoparticles after washing with soap and water were investigated. Bare iron oxide nanoparticles remained primarily on the surface of the skin, without penetrating beyond the stratum corneum. Skin exposed to iron oxide nanoparticles for 1 and 20 hr resulted in removal of 85% and 90%, respectively, of the original dose after washing. In the event of dermal exposure to chemicals, removal is essential to avoid potential local irritation or permeation across skin. Although manufactured at an industrial scale and used extensively in laboratory experiments, limited data are available on the removal of engineered nanoparticles after skin contact. Our finding raises questions about the potential consequences of nanoparticles remaining on the skin and whether alternative washing methods should be proposed. Further studies on skin decontamination beyond use of soap and water are needed to improve the understanding of the potential health consequences of dermal exposure to nanoparticles.

  4. The Use of UAV in Housing Renovation Identification: A Case Study at Taman Manis 2

    Science.gov (United States)

    Mustaffa, A. A.; Hasmori, M. F.; Sarif, A. S.; Ahmad, N. F.; Zainun, N. Y.

    2018-04-01

    Housing industry in Malaysia is growing rapidly due to the increase in population and the arising of economic level of Malaysian people. Most residential houses are built according to the standard residential design that may lead to house renovation by the buyers after purchasing the house. A method of using Unmanned Aerial Vehicle (UAV) monitoring was used to obtain information of the renovated houses directly on-site at Taman Manis 2, Parit Raja, Batu Pahat. Through comparison of image captured by the UAV with the original house plans, we found out that a total of 160 units out of 336 units of houses undergo a renovation process. Surprisingly, 41 units have been renovated illegally which has 40% to 96% of renovation rate. The acquired data were analyzed and can be concluded that the method of using UAVs to obtain information is highly recommended. The study is expected to help Municipal Council to detect improper & illegal renovation by the residents in a residential area.

  5. Candida and Fusarium species known as opportunistic human pathogens from customer-accessible parts of residential washing machines.

    Science.gov (United States)

    Babič, Monika Novak; Zalar, Polona; Ženko, Bernard; Schroers, Hans-Josef; Džeroski, Sašo; Gunde-Cimerman, Nina

    2015-03-01

    Energy constraints have altered consumer practice regarding the use of household washing machines. Washing machines were developed that use lower washing temperatures, smaller amounts of water and biodegradable detergents. These conditions may favour the enrichment of opportunistic human pathogenic fungi. We focused on the isolation of fungi from two user-accessible parts of washing machines that often contain microbial biofilms: drawers for detergents and rubber door seals. Out of 70 residential washing machines sampled in Slovenia, 79% were positive for fungi. In total, 72 strains belonging to 12 genera and 26 species were isolated. Among these, members of the Fusarium oxysporum and Fusarium solani species complexes, Candida parapsilosis and Exophiala phaeomuriformis represented 44% of fungi detected. These species are known as opportunistic human pathogens and can cause skin, nail or eye infections also in healthy humans. A machine learning analysis revealed that presence of detergents and softeners followed by washing temperature, represent most critical factors for fungal colonization. Three washing machines with persisting malodour that resulted in bad smelling laundry were analysed for the presence of fungi and bacteria. In these cases, fungi were isolated in low numbers (7.5 %), while bacteria Micrococcus luteus, Pseudomonas aeruginosa, and Sphingomonas species prevailed. Copyright © 2014 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  6. Impact of electrochemical treatment of soil washing solution on PAH degradation efficiency and soil respirometry

    International Nuclear Information System (INIS)

    Mousset, Emmanuel; Huguenot, David; Hullebusch, Eric D. van; Oturan, Nihal; Guibaud, Gilles; Esposito, Giovanni; Oturan, Mehmet A.

    2016-01-01

    The remediation of a genuinely PAH-contaminated soil was performed, for the first time, through a new and complete investigation, including PAH extraction followed by advanced oxidation treatment of the washing solution and its recirculation, and an analysis of the impact of the PAH extraction on soil respirometry. The study has been performed on the remediation of genuine PAH-contaminated soil, in the following three steps: (i) PAH extraction with soil washing (SW) techniques, (ii) PAH degradation with an electro-Fenton (EF) process, and (iii) recirculation of the partially oxidized effluent for another SW cycle. The following criteria were monitored during the successive washing cycles: PAH extraction efficiency, PAH oxidation rates and yields, extracting agent recovery, soil microbial activity, and pH of soil. Two representative extracting agents were compared: hydroxypropyl-beta-cyclodextrin (HPCD) and a non-ionic surfactant, Tween"® 80. Six PAH with different numbers of rings were monitored: acenaphthene (ACE), phenanthrene (PHE), fluoranthene (FLA), pyrene (PYR), benzo(a)pyrene (BaP), and benzo(g,h,i)perylene (BghiP). Tween"® 80 showed much better PAH extraction efficiency (after several SW cycles) than HPCD, regardless of the number of washing cycles. Based on successive SW experiments, a new mathematical relation taking into account the soil/water partition coefficient (Kd*) was established, and could predict the amount of each PAH extracted by the surfactant with a good correlation with experimental results (R"2 > 0.975). More HPCD was recovered (89%) than Tween"® 80 (79%), while the monitored pollutants were completely degraded (>99%) after 4 h and 8 h, respectively. Even after being washed with partially oxidized solutions, the Tween"® 80 solutions extracted significantly more PAH than HPCD and promoted better soil microbial activity, with higher oxygen consumption rates. Moreover, neither the oxidation by-products nor the acidic media (p

  7. Bacterial flora of processed broiler chicken skin after successive washings in mixtures of potassium hydroxide and lauric acid.

    Science.gov (United States)

    Hinton, Arthur; Cason, John A

    2008-08-01

    Changes in the size of populations of different groups of bacteria composing the normal flora of processed broiler skin were examined after each of five consecutive washings in mixtures of potassium hydroxide (KOH) and lauric acid (LA). Portions of skin from commercially processed broiler carcasses were washed in distilled water (control) or in mixtures of 0.25% KOH-0.5% LA or 0.5% KOH-1% LA by using a stomacher laboratory blender to agitate the skin in the solutions. After each wash, skin was transferred to fresh solutions, and washing was repeated to provide samples washed one to five times in each solution. Bacteria in rinsates of the washed skin were enumerated on plate count (PC) agar, Staphylococcus (STA) agar, Levine eosin methylene blue (EMB) agar, lactic acid bacteria (LAB) agar, and Perfringens (PER) agar with TSC supplement. Selected isolates recovered on each medium were identified. Overall, no significant differences were observed in numbers of bacteria recovered on PC, STA, or EMB agars from skin after repeated washing in water, but there were significant reductions in the number of bacteria recovered on LAB and PER agars. Repeated washing of skin in 0.25% KOH-0.5% LA or 0.5% KOH-1% LA generally produced significant reductions in the number of bacteria recovered on all media. Furthermore, no bacteria were recovered on PER agar from skin washed five times in 0.25% KOH-0.5% LA. Likewise, no bacteria were recovered on EMB or LAB agars from skin washed three or more times in 0.5% KOH-1% LA or on PER agar from skin washed four or five times in this solution. Staphylococcus spp. were identified as the skin isolates with the highest degree of resistance to the bactericidal activity of KOH-LA. Findings indicate that although bacteria may be continually shed from poultry skin after repeated washings, bactericidal surfactants can be used to remove and kill several types of bacteria found on the surface of the skin of processed broilers.

  8. Renovation of food-processing wastewater by a Riparian wetland

    Science.gov (United States)

    Baillie, Priscilla W.

    1995-01-01

    Treated wastewater from a food-processing plant, together with intermittent outflow from a hypereutrophic pond, were discharged over a 20-year period to a cattail-dominated wetland and hence to a small stream. Organics and nutriet levels in the effluent were comparable to levels in domestic wastewater. Fifteen variables were monitored upstream and downstream from the plant over 18 months. Means for most variables were slightly higher downstream, but differences between stations were not statistically significant. Wetland processing of nitrogen was markedly affected by a change from drought to flood conditions. After accounting for dilution, the overall effect of the wetland on the effluent was to reduce biological oxygen demand 43.7%, ammonia N 46.3%, nitrate/nitrite N 17.4%, and conductivity 15.6%. However, total suspended solids were increased 41.4%, total organic nitrogen 28.8%, and total phosphorus 24.7%. It was concluded that the wetland effectively renovated the effluent but the removal efficiency would be improved if the effluent were pretreated to reduce phosphorus and dispersed to increase residence time in the wetland.

  9. Scrubbing water treatment for simultaneous SO/sub 2/ and NO/sub x/ removal from gases, with an integrated stage for reducing Fe-III to Fe-II in the washing liquid circuit by lowering the pH and circulation of SO/sub 2/. Waschwasseraufbereitung fuer die simultane SO/sub 2/- und NO/sub x/-Gasreinigung mit integrierter Stufe zur Reduktion von Eisen-III zu Eisen-II im Waschfluessigkeitskreislauf

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1987-01-08

    In the patent application P 3519681.5 a method for washing water treatment and recovery of valuable material in the simultaneous removal of SO/sub 2/ and NO/sub x/ from flue gas is described. In this method sulphuric acid and air are supplied in the oxidation chamber so that after filtration marketable gypsum is produced as a final product. Surprisingly, it was found out that with a sufficiently high reduction of the pH value to the strongly basic range by addition of sulphuric acid in the range of pH less than 3, iron-III is reduced to iron-II.

  10. Advantage of the renewable energies in isolated zones; Aprovechamiento de las energias renovables en zonas aisladas

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza Zazueta, Jose Antonio [Fideicomiso de Riesgo Compartido de la SAGARPA (Mexico)

    2007-07-15

    The present article has as objective to present the experiences obtained for more than ten years, in the development and implementation of actions that in the matter of renewable energy have been orchestrated in the Mexican field by the Secretariat of Agriculture, Animal Industry, Rural Development, Fishing, and Nutrition, trough the Shared Risk Trust Fund. The activities began in 1994; the most common applications realized are the water pumping for the drinking trough of cattle and the automation of the irrigation in small surfaces with fruit trees, vegetables, forages and the operation of greenhouses. [Spanish] El presente articulo tiene como objetivo presentar las experiencias obtenidas durante mas de diez anos, en el desarrollo e implementacion de acciones que en materia de energia renovable se han instrumentado en el campo mexicano por la the Secretaria de Agricultura, Ganaderia, Desarrollo Rural Pesca y Alimentacion, a traves del Fideicomiso de Riesgo Compartido. Las actividades se iniciaron en 1994, las aplicaciones mas comunes realizadas son el bombeo de agua para el abrevadero de ganado y la tecnificacion del riego en pequenas superficies con frutales, hortalizas, forrajes y la operacion de invernaderos.

  11. Polyester Textiles as a Source of Microplastics from Households: A Mechanistic Study to Understand Microfiber Release During Washing.

    Science.gov (United States)

    Hernandez, Edgar; Nowack, Bernd; Mitrano, Denise M

    2017-06-20

    Microplastic fibers make up a large proportion of microplastics found in the environment, especially in urban areas. There is good reason to consider synthetic textiles a major source of microplastic fibers, and it will not diminish since the use of synthetic fabrics, especially polyester, continues to increase. In this study we provide quantitative data regarding the size and mass of microplastic fibers released from synthetic (polyester) textiles during simulated home washing under controlled laboratory conditions. Consideration of fabric structure and washing conditions (use of detergents, temperature, wash duration, and sequential washings) allowed us to study the propensity of fiber shedding in a mechanistic way. Thousands of individual fibers were measured (number, length) from each wash solution to provide a robust data set on which to draw conclusions. Among all the variables tested, the use of detergent appeared to affect the total mass of fibers released the most, yet the detergent composition (liquid or powder) or overdosing of detergent did not significantly influence microplastic release. Despite different release quantities due to the addition of a surfactant (approximately 0.025 and 0.1 mg fibers/g textile washed, without and with detergent, respectively), the overall microplastic fiber length profile remained similar regardless of wash condition or fabric structure, with the vast majority of fibers ranging between 100 and 800 μm in length irrespective of wash cycle number. This indicates that the fiber staple length and/or debris encapsulated inside the fabric from the yarn spinning could be directly responsible for releasing stray fibers. This study serves as a first look toward understanding the physical properties of the textile itself to better understand the mechanisms of fiber shedding in the context of microplastic fiber release into laundry wash water.

  12. A laboratory study of washing of SRS high-level waste radioactive sludge-evidence for insoluble sodium and cesium-137

    International Nuclear Information System (INIS)

    Hay, M.S.; Bibler, N.E.

    1994-01-01

    Experiments in the Shielded Cells at the Savannah River Technology Center were undertaken to simulate the full-scale sludge washing process and thereby identify potential problems, wash water requirements, sludge settling rates and the fate of various radioactive and non-radioactive species present in the sludge. The laboratory sludge washing experiments were conducted on a radioactive sludge sample taken from one of three processing tanks in Extended Sludge Processing. The sample of Tank 42H sludge was extensively characterized for both soluble and insoluble species (radioactive and non-radioactive) before beginning the washing study. The results of the washing experiments using inhibited water (0.01 M NaOH) indicate there is essentially no dissolution of species from the insoluble phase of the sludge during the washing. The addition of wash water to the sludge merely dilutes the salt dissolved in the interstitial supernate of the sludge. Another result from the experiments is that approximately 30% of the sodium and 86% of the Cs-137 in the original unwashed sludge is present in an insoluble form and does not wash out of the sludge

  13. Using a One-Stop-Shop Concept to Guide Decisions when Single-Family Houses are renovated

    DEFF Research Database (Denmark)

    Grøn Bjørneboe, Matilde; Svendsen, Svend; Heller, Alfred

    2017-01-01

    of renovation. The scope of the project was to carry out renovations on up to three houses. The project revealed that the concept on its own was not enough to motivate the house owners to engage in extensive renovation. However, interviews with the house owners indicated that the renovations that took place had...... was to determine how a one-stop-shop (OSS) or full-service concept could be used to guide the extensive energy renovation of single-family houses. The purpose was partly to identify the benefits and disadvantages of using the concept and partly to evaluate the potential of the OSS concept for increasing the degree...... probably been expanded and improved with the use of the concept and that the renovations in general benefitted from an independent adviser....

  14. EFRT M-12 Issue Resolution: Solids Washing

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, David L.; Schonewill, Philip P.; Toth, James J.; Huckaby, James L.; Eslinger, Paul W.; Hanson, Brady D.; Kurath, Dean E.; Minette, Michael J.

    2010-01-01

    Pacific Northwest National Laboratory (PNNL) was tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes” of the External Flowsheet Review Team (EFRT) issue response plan.( ) The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing.

  15. 100 Areas soil washing tradeoff study

    International Nuclear Information System (INIS)

    Belden, R.D.

    1995-11-01

    The complex nature of cost analysis and systems work demands a level of effort to ensure that decisions made support the best interests of all parties. This tradeoff study will act as a formal decision analysis method for the evaluation of many variables. The documentation of the decision rationale and system design is essential for successful planning and implementation of any system. The Hanford Site offers unique problems for economic analysis of remediation alternatives. The variations in the size of sites, geographic locations, and possible cleanup scenarios all add to the complexity of the tradeoff analysis. A thorough examination of all alternatives must be held to a level of detail appropriate to current regulatory and budgetary considerations. This study will compare the economics of two specific alternatives for remediation of soils at the Hanford Site. Remove and dispose is compared to remove, treat, and dispose. The treatment analyzed in this study is volume reduction through soil washing

  16. Innovative Technology for Preparing Washing Liquid During Well Drilling

    Directory of Open Access Journals (Sweden)

    Davydenko A.N.

    2015-09-01

    Full Text Available Technology of washings liquid preparation is worked out. Prospects of the hydrodynamic supercavitation use for preparation of washing liquids during well drilling are substantiated. Theoretical research make it possible to set parameters and work out the construction of cavitational dispergator. The results of theoretical research found their confirmation during practical examinations and became the basis for creation of the technique of washing liquid preparation and construction of cavitational dispergator tested in production conditions.

  17. The effect of Ebola Virus Disease outbreak on hand washing among secondary school students in Ondo State Nigeria, October, 2014.

    Science.gov (United States)

    Ilesanmi, Olayinka Stephen; Alele, Faith Osaretin

    2015-01-01

    Hand washing with soap and water is one of the cheapest, most effective ways of limiting the spread of Ebola Virus Disease (EVD). Despite its importance the prevalence of hand washing was low before the EVD outbreak in Nigeria. This study aimed at determining the factors associated with improved hand washing practices following the EVD outbreak. A descriptive cross sectional study of 440 students from a secondary school in Owo, Ondo State was done. Data was collected in October 2014 when Nigeria was yet to be declared EVD free. Systematic random sampling was used. A semi-structured, interviewer administered questionnaire was used. Data was analysed with epi info version 7, descriptive statistics were done, Chi square test was used for the assessment of significant associations between proportions. Determinants of good hand washing practices was identified using logistics regression analysis at 5% level of significance. Of 440 respondents, mean age was 13.7±1.9 years. Females were 48.2%. Only 4.6% have never heard of Ebola Virus Disease.Level of hand washing with soap and water improved by62.6%. Significant improvement in hand washing was in 75.8% of those who heard through social media (p Newspaper readers(p schools.

  18. Optimizing the molarity of a EDTA washing solution for saturated-soil remediation of trace metal contaminated soils

    International Nuclear Information System (INIS)

    Andrade, M.D.; Prasher, S.O.; Hendershot, W.H.

    2007-01-01

    Three experiments were conducted to optimize the use of ethylenediaminetetraacetic acid (EDTA) for reclaiming urban soils contaminated with trace metals. As compared to Na 2 EDTA (NH 4 ) 2 EDTA extracted 60% more Zn and equivalent amounts of Cd, Cu and Pb from a sandy loam. When successively saturating and draining loamy sand columns during a washing cycle, which submerged it once with a (NH 4 ) 2 EDTA wash and four times with deionised water, the post-wash rinses largely contributed to the total cumulative extraction of Cd, Co, Cr, Cu, Mn, Ni, Pb and Zn. Both the washing solution and the deionised water rinses were added in a 2:5 liquid to soil (L:S) weight ratio. For equal amounts of EDTA, concentrating the washing solution and applying it and the ensuing rinses in a smaller 1:5 L:S weight ratio, instead of a 2:5 L:S weight ratio, increased the extraction of targeted Cr, Cu, Ni, Pb and Zn. - A single EDTA addition is best utilised in a highly concentrated washing solution given in a small liquid to soil weight ratio

  19. Simulation of flow in the unsaturated zone beneath Pagany Wash, Yucca Mountain

    International Nuclear Information System (INIS)

    Kwicklis, E.M.; Healy, R.W.; Flint, A.L.

    1994-01-01

    A one-dimensional numerical model was created to simulate water movement beneath Pagany Wash, Yucca Mountain, Nevada. Model stratigraphy and properties were based on data obtained from boreholes UE-25 UZ No. 4 and UE-25 UZ No. 5, which was drilled in the alluvial channel and bedrock sideslope of Pagany Wash. Although unable to account for multidimensional or preferential flowpaths beneath the wash, the model proved a useful conceptual tool with which to develop hypotheses and, in some cases, provide bounding calculations. The model indicated that liquid flux decreases with depth in the upper 120 m beneath the wash, with fluxes of several tens mm/yr in the nonwelded base of the Tiva Canyon Member and fluxes on the order of a tenth mm/yr in the upper Topopah Spring Member. Capillary barrier effects were indicated by the model to significantly delay the entry of large fluxes into the potential repository horizon during periods of increasing net infiltration, and to inhibit rapid drainage of water from the nonwelded and bedded intervals into the potential repository horizon during periods of moisture redistribution. Lateral moisture redistribution can be expected to be promoted by these effects

  20. Efficacy of household washing treatments for the control of Listeria monocytogenes on salad vegetables.

    Science.gov (United States)

    Nastou, Aikaterini; Rhoades, Jonathan; Smirniotis, Petros; Makri, Ioanna; Kontominas, Michael; Likotrafiti, Eleni

    2012-10-15

    The efficacy of household decontamination methods at reducing Listeria monocytogenes on fresh lettuce (Lactuca sativa), cucumber (Cucumis sativus) and parsley (Petroselinum sativum) was studied. Inoculated vegetable pieces were immersed in washing solutions and surviving L. monocytogenes enumerated. Parameters investigated were storage temperature prior to washing, dipping water temperature, agitation, acetic acid concentration and immersion time. The results indicated that the storage temperature significantly affects the efficacy of dipping vegetables in water for the control of L. monocytogenes, as the reduction in count was greatest when products had been stored at cooler temperatures. Decontamination with acetic acid (up to 2.0% v/v) was shown to have some effect in most cases, but the highest observed decrease in count was 2.6 log cfu/g. Experiments investigating the effect of exposure time to acetic acid (0.5% and 1.0% v/v, up to 30 min immersion) indicated that immersing the vegetables for more than 10 min is of minimal benefit. The most significant factor affecting washing and decontamination efficacy was the vegetable itself: L. monocytogenes colonizing cucumber epidermis was far more resistant to removal by washing and to acid treatment than that on the leafy vegetables, and L. monocytogenes on parsley was the most susceptible. This shows that published decontamination experiments (often performed with lettuce) cannot necessarily be extrapolated to other vegetables. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. The Effect of Washing and Peeling on Reduction of Dithiocarbamates Residues in Cucumber and Tomato

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Mehrasebi

    2016-03-01

    Full Text Available Background: Dithiocarbamates, the main group of fungicides, are used to control about 400 pathogens in more than 70 crops. These pesticides are widely applied to crops including potato, cereal, apple, pear and leafy vegetables throughout the world since 1960. From the late 1980s, using these fungicides has caused much debate among regulators about their long-term effects on consumers and occupational users. Method: In this study the residues of Dithiocarbamates in cucumber and tomato using the colorimetric method (Keppel method was measured. Respectively 80 and 45 samples of greenhouse cucumber and tomato were collected from Zanjan vegetables center in autumns and winter 2013. The samples were analyzed in 4 treatments of: unwashed, washing with water, washing whit detergent and peeling. Result: The results showed that the average concentration of Dithiocarbamates residues in unwashed greenhouse cucumber and tomatoes were 384.5 µg/kg and 65 µg/kg respectively. 35% and 5% of unwashed and water washed cucumber and tomato samples (respectively had higher Dithiocarbamates residue than MRL recommended by Institute of Standards and Industrial Research of Iran (0.5mg/kg. Conclusion: The treatments of washing and peeling had significant effect on the reduction of Dithiocarbamates residues in the all samples.

  2. Irreversible Wash Aid Additive for Cesium Mitigation. Small-Scale Demonstration and Lessons Learned

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Michael [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-01-01

    The Irreversible Wash Aid Additive process has been under development by the U.S. Environmental Protection Agency (EPA) and Argonne National Laboratory (Argonne). This process for radioactive cesium mitigation consists of a solution to wash down contaminated structures, roadways, and vehicles and a sequestering agent to bind the radionuclides from the wash water and render them environmentally immobile. The purpose of this process is to restore functionality to basic services and immediately reduce the consequences of a radiologically-contaminated urban environment. Research and development have resulted in a down-selection of technologies for integration and demonstration at the pilot-scale level as part of the Wide Area Recovery and Resiliency Program (WARRP) under the Department of Homeland Security and the Denver Urban Area Security Initiative. As part of developing the methods for performing a pilot-scale demonstration at the WARRP conference in Denver in 2012, Argonne conducted small-scale field experiments at Separmatic Systems. The main purpose of these experiments was to refine the wash water collection and separations systems and demonstrate key unit operations to help in planning for the large scale demonstration in Denver. Since the purpose of these tests was to demonstrate the operations of the system, we used no radioactive materials. After a brief set of experiments with the LAKOS unit to familiarize ourselves with its operation, two experiments were completed on two separate dates with the Separmatic systems.

  3. Fenton oxidation treatment of spent wash-off liquor for reuse in reactive dying

    International Nuclear Information System (INIS)

    Mangat, A.; Shaikh, I.A.; Ahmed, F.; Baqar, M

    2014-01-01

    The use of clean and high quality water in textile dyeing process is very expensive. In this study, the potential of reusing Fenton treated wash-off wastewater generated at the end of reactive dyeing was investigated. The treated wastewater was used in several dyeings employing three widely used reactive dyes, C. I. Reactive Yellow 145, C. I. Reactive Red 194, and C. I. Reactive Blue 221. Experimental results showed that at acidic pH (3.5) using optimized quantities of FeSO/sub 4/ and H/sub 2/O/sub 2/, Fenton process yielded a significant reduction (80-99%) of colour and COD in 30 minutes of treatment time. New dyeings were then carried out in Fenton decolourized wash-off wastewater, and dyed fabric samples were subjected to quality evaluations in terms of wash fastness, crock fastness, and colour difference properties (delta L*, delta c*, delta h*, and delta E*). This study concluded that Fenton oxidation was an efficient method for the treatment of textile wash-off wastewater, and treated liquor can be effectively recycled in next dyeing, without compromising quality parameters. This method proved to be an eco-friendly process owing to the fact that it did not use any fresh water. (author)

  4. Heavy metal removal by GLDA washing: Optimization, redistribution, recycling, and changes in soil fertility.

    Science.gov (United States)

    Wang, Guiyin; Zhang, Shirong; Xu, Xiaoxun; Zhong, Qinmei; Zhang, Chuer; Jia, Yongxia; Li, Ting; Deng, Ouping; Li, Yun

    2016-11-01

    Soil washing, an emerging method for treating soils contaminated by heavy metals, requires an evaluation of its efficiency in simultaneously removing different metals, the quality of the soil following remediation, and the reusability of the recycled washing agent. In this study, we employed N,N-bis (carboxymethyl)-l-glutamic acid (GLDA), a novel and readily biodegradable chelator to remove Cd, Pb, and Zn from polluted soils. We investigated the influence of washing conditions, including GLDA concentration, pH, and contact time on their removal efficiencies. The single factor experiments showed that Cd, Pb, and Zn removal efficiencies reached 70.62, 74.45, and 34.43% in mine soil at a GLDA concentration of 75mM, a pH of 4.0, and a contact time of 60min, and in polluted farmland soil, removal efficiencies were 69.12, 78.30, and 39.50%, respectively. We then employed response surface methodology to optimize the washing parameters. The optimization process showed that the removal efficiencies were 69.50, 88.09, and 40.45% in mine soil and 71.34, 81.02, and 50.95% in polluted farmland soil for Cd, Pb, and Zn, respectively. Moreover, the overall highly effective removal of Cd and Pb was connected mainly to their highly effective removal from the water-soluble, exchangeable, and carbonate fractions. GLDA-washing eliminated the same amount of metals as EDTA-washing, while simultaneously retaining most of the soil nutrients. Removal efficiencies of recycled GLDA were no >5% lower than those of the fresh GLDA. Therefore, GLDA could potentially be used for the rehabilitation of soil contaminated by heavy metals. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Possibilities of soil washing for decontamination at Belgoprocess

    Energy Technology Data Exchange (ETDEWEB)

    Aerts, Wouter [Belgoprocess, Dessel, Antwerp (Belgium); De Bruecker, Thomas; Lytek, Anna [DEC - DEME Environmental Contractor, Zwijndrecht, Antwerp (Belgium)

    2013-07-01

    Contaminated soils form a large part of the nuclear waste arising from decommissioning activities. The storage and disposal of these large volumes of waste is costly. For this reason techniques which can decontaminate this waste stream to free release levels are economically very interesting. A feasibility study of the possibilities of soil washing to decontaminate such soils was ordered by NIRAS/ONDRAF and performed at Belgoprocess in collaboration with DEC. Initial contamination level and particle size distributions of contaminated soils from three different sources were determined. The main isotopes detected with gamma spectrometry contained in the waste were {sup 241}Am, {sup 137}Cs, {sup 226}Ra, {sup 60}Co and {sup 232}Th. The particle size distribution revealed that more than half of the mass of the quartz sand that makes up the soil has a particle size between 125 and 212 μm. This fraction is less contaminated than the fractions containing smaller particles. However, separation of the fines fraction (< 125 μm) was not enough to achieve the free release limit. Soil attrition was tested as an extra decontamination step for the sand fraction. The removal efficiencies for the different radionuclides contained in the soil were measured. The process conditions were optimized to achieve maximum removal and a treatment method for the secondary waste coming from this process step was determined. The soil washing process was not only performed with water but also with nitric acid to assess the possibilities of a combination of a mechanical and a chemical decontamination process. Reduction efficiencies of 60-80% for the most relevant radionuclides were recorded. (authors)

  6. Rapid washing of filter paper discs in a solid-phase radioimmunoassay with a constant flow washing device

    International Nuclear Information System (INIS)

    Kemeny, D.M.; West, F.B.

    1982-01-01

    A machine has been developed for the rapid washing of the cellulose filter paper discs that are used in a number of radioimmunoassays. The machine is simple in design, easy to use, and is capable of washing 96 filter paper discs simultaneously. The efficiency of the machine is demonstrated by a RAST assay for measuring IgE antibodies to the venom. Time taken to wash the discs was reduced 3-fold without loss of sensitivity or reproducibility. (Auth.)

  7. Natural attenuation of NDMA precursors in an urban, wastewater-dominated wash.

    Science.gov (United States)

    Woods, Gwen C; Dickenson, Eric R V

    2016-02-01

    N-Nitrosodimethylamine (NDMA) is a disinfection by-product (DBP) that is potentially carcinogenic and has been found to occur in drinking water treatment systems impacted with treated wastewater. A major gap in NDMA research is an understanding of the persistence of wastewater-derived precursors within the natural environment. This research sought to fill this knowledge gap by surveying NDMA precursors across the length of a wastewater effluent-dominated wash. Significant precursor reduction (17%) was found to occur from introduction into the wash to a point 9 h downstream. This reduction translates into a half-life of roughly 32 h for bulk NDMA precursors. Further laboratory experiments examining rates of photolysis, biodegradation and loss to sediments, illustrated that both photolytic and biological degradation were effective removal mechanisms for NDMA precursors. Loss to sediments that were acquired from the wash did not appear to reduce NDMA precursors in the water column, although a control conducted with DI water provided evidence that significant NDMA precursors could be released from autoclaved sediments (suggesting that sorption does occur). Microbial experiments revealed that microbes associated with sediments were much more effective at degrading precursors than microbes within the water column. Overall, this study demonstrated that natural processes are capable of attenuating NDMA precursors relatively quickly within the environment, and that utilities might benefit from maximizing source water residency time in the environment, prior to introduction into treatment plants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Basic characteristics of leachate produced by various washing processes for MSWI ashes in Taiwan.

    Science.gov (United States)

    Yang, Renbo; Liao, Wing-Ping; Wu, Pin-Han

    2012-08-15

    Approximately 19.2% of Taiwan's municipal solid waste (MSW) that passes through incineration disposal is converted into ashes (including bottom ash and fly ash). Although bottom ash can pass nearly all of the standards of the toxicity characteristic leaching procedure (TCLP), its high chloride content makes its reuse limited; it generally cannot be used as a fine aggregate material in concrete applications. This research examined washing four types of bottom ash (BA) and fly ash (FA) with water to reduce their chloride content. The optimal water intensity for washing pretreated bottom ash was found to be 7-8L of water per kg of bottom ash, and the optimal water intensity for washing untreated fly ash was found to be 20-25 L of water per kg of fly ash. Based on regression analyses of the chloride concentrations of the leachates and their electrical conductivity (EC) values, each MSW incineration plant has its own ash characteristics as well as a specific regression line in bottom or fly ash leachate. Clearly, it is possible to monitor the EC values of the leachates online by estimation from regression equations to determine the chloride concentrations in the leachates. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  9. Effectiveness of Commercial and Homemade Washing Agents in Removing Pesticide Residues on and in Apples.

    Science.gov (United States)

    Yang, Tianxi; Doherty, Jeffery; Zhao, Bin; Kinchla, Amanda J; Clark, John M; He, Lili

    2017-11-08

    Removal of pesticide residues from fresh produce is important to reduce pesticide exposure to humans. This study investigated the effectiveness of commercial and homemade washing agents in the removal of surface and internalized pesticide residues from apples. Surface-enhanced Raman scattering (SERS) mapping and liquid chromatography tandem mass spectrometry (LC-MS/MS) methods were used to determine the effectiveness of different washing agents in removing pesticide residues. Surface pesticide residues were most effectively removed by sodium bicarbonate (baking soda, NaHCO 3 ) solution when compared to either tap water or Clorox bleach. Using a 10 mg/mL NaHCO 3 washing solution, it took 12 and 15 min to completely remove thiabendazole or phosmet surface residues, respectively, following a 24 h exposure to these pesticides, which were applied at a concentration of 125 ng/cm 2 . LC-MS/MS results showed, however, that 20% of applied thiabendazole and 4.4% of applied phosmet had penetrated into the apples following the 24 h exposure. Thiabendazole, a systemic pesticide, penetrated 4-fold deeper into the apple peel than did phosmet, a non-systemic pesticide, which led to more thiabendazole residues inside the apples, which could not be washed away using the NaHCO 3 washing solution. This study gives us the information that the standard postharvest washing method using Clorox bleach solution for 2 min is not an effective means to completely remove pesticide residues on the surface of apples. The NaHCO 3 method is more effective in removing surface pesticide residues on apples. In the presence of NaHCO 3 , thiabendazole and phosmet can degrade, which assists the physical removal force of washing. However, the NaHCO 3 method was not completely effective in removing residues that have penetrated into the apple peel. The overall effectiveness of the method to remove all pesticide residues diminished as pesticides penetrated deeper into the fruit. In practical application

  10. How to get residents/owners in housing cooperatives to agree on sustainable renovation

    Energy Technology Data Exchange (ETDEWEB)

    Lappegard Hauge, A. [SINTEF Building and Infrastructure, P.O. Box 124, Blindern, 0314 Oslo (Norway); Thomsen, J. [SINTEF Building and Infrastructure, 7465 Trondheim (Norway); Loefstroem, E. [SINTEF Building and Infrastructure, 7491 Trondheim (Norway)

    2013-05-15

    What factors increase the chance that residents/owners in housing cooperatives agree on sustainable energy efficient renovation? Based on 30 qualitative interviews with professional advisors in cooperative housing associations and chairman/board and residents in three chosen case studies, an analysis of opportunities and barriers for making a common decision on renovation is performed. Success criteria and barriers are found on the societal level as well as on the organizational/individual level. The barriers and success criteria identified on the societal level are: knowledge level on energy-efficient renovation among relevant actors, owner structure of the housing cooperative, and existing regulations and incentives. On the organizational and individual level, the following categories influencing renovation processes were identified: the time frame and organization of the process, understanding the residents' needs, economy, the information given, and the existence of available exemplary projects and role models. Based on the results of the study, ten guidelines that contribute to more successful decision making processes and increase the chances of sustainable energy efficient renovation in housing cooperatives are presented.

  11. Road dust emission sources and assessment of street washing effect

    NARCIS (Netherlands)

    Karanasiou, A.; Amato, F.; Moreno, T.; Lumbreras, J.; Borge, R.; Linares, C.; Boldo, E.; Alastuey, A.; Querol, X.

    2014-01-01

    Although previous studies report on the effect of street washing on ambient particulate matter levels, there is a lack of studies investigating the results of street washing on the emission strength of road dust. A sampling campaign was conducted in Madrid urban area during July 2009 where road dust

  12. Hand Washing Practices and Compliance among Health Care ...

    African Journals Online (AJOL)

    Hand washing is the simplest, most inexpensive and most effective method of reducing the incidence of hospital-acquired infections in the Intensive Care Unit. Several reports have shown a relationship between improved hand washing practices and reduced infection rates. We conducted a prospective, ...

  13. Evaluation of washing machine load potential for smart grid integration

    NARCIS (Netherlands)

    Klaassen, E.A.M.; Kobus, C.B.A.; Huijkelom, M.; Frunt, J.; Slootweg, J.G.

    2013-01-01

    This paper presents the lessons learned from a smart wash pilot, conducted with 24 employees of distribution system operator Enexis, who were equipped with an energy computer, smart washing machine, photovoltaic panels and smart meter. The pilot goal was to gain experience and knowledge about the

  14. Salmonella transfer during pilot plant scale washing and roller conveying of tomatoes.

    Science.gov (United States)

    Wang, Haiqiang; Ryser, Elliot T

    2014-03-01

    Salmonella transfer during washing and roller conveying of inoculated tomatoes was quantified using a pilot scale tomato packing line equipped with plastic, foam, or brush rollers. Red round tomatoes (2.3 kg) were dip inoculated with Salmonella enterica serovar Typhimurium LT2 (avirulent) (4 log CFU/g), air dried for 2 h, and then washed in sanitizer-free water for 2 min. Inoculated tomatoes were then passed single file over a 1.5-m conveyor equipped with plastic, foam, or brush rollers followed by 25 previously washed uninoculated tomatoes. Tomato samples were collected after 2 min of both washing and roller conveying, with all 25 uninoculated tomatoes collected individually after conveying. Roller surface samples were collected before and after conveying the uninoculated tomatoes. Both tomato and surface samples were quantitatively examined for Salmonella by direct plating or membrane filtration using xylose lysine Tergitol 4 agar. Regardless of the roller type, Salmonella populations on inoculated tomatoes did not significantly (P conveyors. After conveying uninoculated tomatoes over contaminated foam rollers, 96% of the 25 tomatoes were cross-contaminated with Salmonella at >100 CFU per tomato. With plastic rollers, 24 and 76% of tomatoes were cross-contaminated with Salmonella at 10 to 100 and 1 to 10 CFU per tomato, respectively. In contrast, only 8% of 25 tomatoes were cross-contaminated with brush rollers with Salmonella populations of 1 to 10 CFU per tomato. Overall, cross-contamination was greatest with foam, followed by plastic and brush rollers (P < 0.05). Adding peroxyacetic acid or chlorine to the wash water significantly decreased cross-contamination during tomato conveying, with chlorine less effective in controlling Salmonella on foam compared with plastic and brush rollers.

  15. Soil remediation: humic acids as natural surfactants in the washings of highly contaminated soils

    International Nuclear Information System (INIS)

    Conte, Pellegrino; Agretto, Anna; Spaccini, Riccardo; Piccolo, Alessandro

    2005-01-01

    The remediation of the highly contaminated site around the former chemical plant of ACNA (near Savona) in Northern Italy is a top priority in Italy. The aim of the present work was to contribute in finding innovative and environmental-friendly technology to remediate soils from the ACNA contaminated site. Two soils sampled from the ACNA site (A and B), differing in texture and amount and type of organic contaminants, were subjected to soil washings by comparing the removal efficiency of water, two synthetic surfactants, sodium dodecylsulphate (SDS) and Triton X-100 (TX100), and a solution of a natural surfactant, a humic acid (HA) at its critical micelle concentration (CMC). The extraction of pollutants by sonication and soxhlet was conducted before and after the soil washings. Soil A was richer in polycyclic aromatic hydrocarbons, whereas soil B had a larger content of thiophenes. Sonication resulted more analytically efficient in the fine-textured soil B. The coarse-textured soil A was extracted with a general equal efficiency also by soxhlet. Clean-up by water was unable to exhaustively remove contaminants from the two soils, whereas all the organic surfactants revealed very similar efficiencies (up to 90%) in the removal of the contaminants from the soils. Hence, the use of solutions of natural HAs appears as a better choice for soil washings of highly polluted soils due to their additional capacity to promote microbial activity, in contrast to synthetic surfactants, for a further natural attenuation in washed soils. - Solutions of natural humic acids appear to be a better choice for washing highly polluted soils

  16. Characteristics and settling behaviour of particles from blast furnace flue gas washing.

    Science.gov (United States)

    Kiventerä, Jenni; Leiviskä, Tiina; Keski-Ruismäki, Kirsi; Tanskanen, Juha

    2016-05-01

    A lot of particles from iron-making are removed with blast furnace off-gas and routed to the gas cleaning system. As water is used for cleaning the gas, the produced wash water contains a large amount of particles such as valuable Fe and C. However, the presence of zinc prevents recycling. In addition, the high amount of calcium results in uncontrolled scaling. Therefore, the properties of the wash water from scrubber and sludge, from the Finnish metal industry (SSAB Raahe), were evaluated in this study. Size fractionation of wash water revealed that Fe, Zn, Al, Mn, V, Cr and Cd appeared mainly in the larger fractions (>1.2 μm) and Na, Mg, Si, Ni, K, Cu and As appeared mainly in the smaller fractions (<1.2 μm) or in dissolved form. Calcium was found both in the larger fractions and dissolved (∼60 mg/L). Most of the particles in wash water were included in the 1.2-10 μm particle size and were settled effectively. However, a clear benefit was observed when using a chemical to enhance particle settling. In comparison to 2.5 h of settling without chemical, the turbidity was further decreased by about 94%, iron 85% and zinc 50%. Coagulation-flocculation experiments indicated that both low and high molecular weight cationic polymers could provide excellent purification results in terms of turbidity. Calcium should be removed by other methods. The particles in sludge were mostly in the 2-4 μm or 10-20 μm fractions. Further sludge settling resulted in high solids removal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Wash-off effects in urban areas

    International Nuclear Information System (INIS)

    Mueck, K.; Steger, F.

    1991-01-01

    The reduction of the activity distributed in urban areas in three Austrian cities after a radioactive fall-out, by run-off and wash-off effects from stabilised surfaces and the resulting dose reduction to the population were investigated four years after the Chernobyl fall-out to predict the long term external exposure of the population. The measurements were performed in cities with different fractions of dry and wet deposition after the Chernobyl accident in order to determine whether any differences in radionuclide removal with regard to wet and dry fall-out was observable. High resolution in situ gamma spectroscopy was employed to measure the gamma flux from 137 Cs and 134 Cs at points over stabilised surfaces, which was then compared with undisturbed grass surfaces. The average reduction of the place activity on stabilised surfaces amounted to a factor of 10±5 compared to the original deposition after the fall-out. Asphalt showed the highest reduction factor (11.4), concrete less (8.1), stone slabs and cobblestone only about 4.5 and gravel virtually no reduction (1.1). Only very little variation of this reduction with dry or wet deposition was observed. (author)

  18. Extraction agents for the removal of polycyclic aromatic hydrocarbons (PAHs) from soil in soil washing technologies

    International Nuclear Information System (INIS)

    Lau, Ee Von; Gan, Suyin; Ng, Hoon Kiat; Poh, Phaik Eong

    2014-01-01

    Polycyclic aromatic hydrocarbons (PAHs) in soil have been recognised as a serious health and environmental issue due to their carcinogenic, mutagenic and teratogenic properties. One of the commonly employed soil remediation techniques to clean up such contamination is soil washing or solvent extraction. The main factor which governs the efficiency of this process is the solubility of PAHs in the extraction agent. Past field-scale soil washing treatments for PAH-contaminated soil have mainly employed organic solvents or water which is either toxic and costly or inefficient in removing higher molecular weight PAHs. Thus, the present article aims to provide a review and discussion of the alternative extraction agents that have been studied, including surfactants, biosurfactants, microemulsions, natural surfactants, cyclodextrins, vegetable oil and solution with solid phase particles. These extraction agents have been found to remove PAHs from soil at percentages ranging from 47 to 100% for various PAHs. -- Highlights: • The alternative and advancement in extraction agents to remove PAHs from soil using soil washing technology is summarised. • The soil regulations for PAH level in various countries are summarized for reference to researchers. • The concentration levels of PAHs in soil at present and the need for soil remediation is presented. -- The efficiency of the extraction agent plays a significant role in soil washing of PAH-contaminated soil

  19. Copper Recovery from Polluted Soils Using Acidic Washing and Bioelectrochemical Systems

    Directory of Open Access Journals (Sweden)

    Karin Karlfeldt Fedje

    2015-07-01

    Full Text Available Excavation followed by landfilling is the most common method for treating soils contaminated by metals. However, as this solution is not sustainable, alternative techniques are required. Chemical soil washing is one such alternative. The aim of this experimental lab-scale study is to develop a remediation and metal recovery method for Cu contaminated sites. The method is based on the washing of soil or ash (combusted soil/bark with acidic waste liquids followed by electrolytic Cu recovery by means of bioelectrochemical systems (BES. The results demonstrate that a one- or two-step acidic leaching process followed by water washing removes >80 wt. % of the Cu. Copper with 99.7–99.9 wt. % purity was recovered from the acidic leachates using BES. In all experiments, electrical power was generated during the reduction of Cu. This clearly indicates that Cu can also be recovered from dilute solutions. Additionally, the method has the potential to wash co-pollutants such as polycyclic aromatic hydrocarbons (PAHs and oxy-PAHs.

  20. Effect of washing and boiling on residues of pirimiphos-methyl in soybeans

    International Nuclear Information System (INIS)

    Sulistiawaty, M.; Anwar, E.

    1996-01-01

    The residues of pirimiphos-methyl (0-2-diethylamino-6-methyl-pyrimidine-4-il-o-dimethyl phos-phorothioate) in soybean grains were studied using 14 C-labelled-pirimiphos-methyl. Jute sock containing soybean grains were sprayed with pirimiphos-methyl and then stored at room temperature. The results indicated than residues of pirimiphos-methyl in soybeans before washing, after washing, and after washing + boiling at 0 week storage were: 1.0, 0.42, and 0.01%: then increased to 42.01, 30.75, and 10.02%, respectively, after 12 weeks, and finally decreased to 38.33, 27.01, and 6.10%, respectively, after 24 weeks storage. The residues of pirimiphos-methyl in washing water at 0 week storage was 0.41%, then increased to 8.01% after 24 weeks storage. The percentage was calculated based on the amount of residue found compared to the initial pirimiphos-methyl used. (author)

  1. Washing enhanced electrokinetic remediation for removal cadmium from real contaminated soil

    International Nuclear Information System (INIS)

    Giannis, Apostolos; Gidarakos, Evangelos

    2005-01-01

    The main objective of this study is to evaluate the combination of electrokinetic remediation and soil washing technology in order to remove cadmium from contaminated soil. This paper presents the results of an experimental research undertaken to evaluate different washing and purging solutions to enhance the removal of cadmium from a real contaminated soil during electrokinetic remediation. Two different experimental modules were applied in the laboratory. Soil was saturated with tap water, while acetic and hydrochloric acids, as well as ethylenediaminetetraacetic acid (EDTA) were used as purging solutions in the first module. Results show that there was a decrease of cadmium concentration near anode, but a significant increase in the middle of the cell, due to the increasing pH. Citric, nitric and acetic acids were used for soil washing and purging solutions in the second module. In this case, an 85% reduction of cadmium concentration was achieved. Therefore, results indicate that soil pH and washing solutions are the most important factors in governing the dissolution and/or desorption of Cd in a soil system under electrical fields

  2. Evaluation of radiocaesium wash-off by soil erosion from various land uses using USLE plots

    International Nuclear Information System (INIS)

    Yoshimura, Kazuya; Onda, Yuichi; Kato, Hiroaki

    2015-01-01

    Radiocaesium wash-off associated with soil erosion in different land use was monitored using USLE plots in Kawamata, Fukushima Prefecture, Japan after the Fukushima Dai-ichi Nuclear Power Plant accident. Parameters and factors relating to soil erosion and 137 Cs concentration in the eroded soil were evaluated based on the field monitoring and presented. The erosion of fine soil, which is defined as the fraction of soil overflowed along with discharged water from a sediment-trap tank, constituted a large proportion of the discharged radiocaesium. This indicated that the quantitative monitoring of fine soil erosion is greatly important for the accurate evaluation of radiocaesium wash-off. An exponential relationship was found between vegetation cover and the amount of eroded soil. Moreover, the radiocaesium concentrations in the discharged soil were greatly affected by the land use. These results indicate that radiocaesium wash-off related to vegetation cover and land use is crucially important in modelling radiocaesium migration. - Highlights: • Fine soil erosion showed large impact on radiocaesium wash-off. • Exponential relationship was found between vegetation cover and eroded soil. • Radiocaesium concentration in the discharged soil was depending on land use

  3. Clay-oil flocculation during surf washing at the Sea Empress incident

    International Nuclear Information System (INIS)

    Wood, P.; Lunel, T.; Bailey, N.; Lee, K.

    1997-01-01

    Results of investigations into clay-oil flocculation during surf washing of oiled cobbles at Marros Beach, as a response to oiling during the Sea Empress incident, were summarized. Stranded oil on the cobble storm beach was found to associate with fine minerals and form flocs when introduced into sea water. The emulsions persisted for about 14 days after the oiling, after which it begun to disintegrate. After 50 days the remaining emulsion was found to be unstable and penetrated the beach to depths of up to three meters. Since no evidence of biodegradation was found during this period, oil reduction was attributed to sheening, facilitated by tidal fluctuations. Surf washing operation was undertaken over a seven day period beginning 47 days after the spill. Some 8150 tonnes of oiled cobbles were moved a distance of between 12 and 18 m seaward along a length of 850 m. Analysis of samples after two days following surf washing showed that oil concentration did not exceed 22 ppm, compared to 700 ppm before relocation. The significant reduction was considered to have been the result of enhanced oil dispersion coupled with the effects of the surf washing operations. 10 refs., 7 tabs., 10 figs

  4. [Microbiological characteristics of selected liquid soaps for hands washing].

    Science.gov (United States)

    Tyski, Stefan; Bocian, Ewa; Zawistowska, Anna; Mrówka, Agnieszka; Kruszewska, Hanna; Grzybowska, Wanda; Zareba, Tomasz

    2013-01-01

    According to common belief, supported by the authority of the World Health Organization - WHO, the common (social) hand washing is the simplest, cheapest and the most effective way of reduction the hospital-acquired infections. For this purpose products of"liquid soaps", present in a large number on the market, are most often applied. Microbiological status (microbiological purity and antimicrobial activity) of"liquid soaps" available on the Polish market is not known, because relevant routinely studies have not been performed. Only the antibacterial and / or antifungal activity of certain formulations is sometimes assessed, especially when the manufacturer suggests the standardized application of the products for surgical or hygienic procedures. The aim of this study was to determine the microbiological quality, especially microbiological purity and antimicrobial activity of the selected hands washing products, presents on the Polish market. The 12 selected commercial products, available on the market in Poland, dedicated for hands washing were included into study. Microbiological purity test was carried out in accordance with the Polish Pharmacopoeia (FP) monograph (FP monograph numbers correspond to numbers of the European Pharmacopoeia monograph- Ph. Eur.) No 2.6.12 "Microbiological examination of non-sterile products: microbial enumaration tests", and the monograph of FP No. 2.6.13 "Microbiological examination of non-sterile products: test for specified microorganisms". The following physico-chemical properties of soaps were examined: the pH of the formulations was measured according to the monograph FP No. 2.2.3. "Potentiometric determination of pH", the density of products was assayed according to the monograph FPNo. 2.2.5. "Relative density" and determination the water activity was performed by monograph FP No 2.9.39 "Water-solid interactions: determination of sorption-desorption isotherms and of water activity". Next, antibacterial and antifungal

  5. Curricular renovation in the phonoaudiology program of the University of Cauca: a proposal for educational quality

    Directory of Open Access Journals (Sweden)

    Liliana María Pérez-Tenorio

    2010-09-01

    Full Text Available In Colombia, the Superior Education is going through a transformation process. These changes must be in coherence with the formulation of flexible policies among the diverse components of the curriculum and with the need for new forms of working and producing knowledge. The curricular renovation must ref lect an educational quality compromise and contribute to generate human development with high social impact. This article presents a proposal for Curricular Renovation, elaborated by faculty and students of the Phonoaudiology Program of the University of Cauca. This document contains aspects related to the pedagogic model, didactics, faculty-student relation, systems of evaluation and plan of studies. Furthermore, in this document the bases for the Route of Curricular Renovation are presented, consisting of the following phases: background, diagnosis and operational plan. These should facilitate the academic integration for adjusting the curricular processes to the needs of the academic program in a local, national and international context.

  6. Method for planning extensive energy renovation of detached single-family houses

    DEFF Research Database (Denmark)

    Grøn Bjørneboe, Matilde

    , and 22% occurs in single-family houses, making this the largest single contributor to the total consumption after road transport (DEA, 2015a). There is a large potential for achieving energy savings in this sector, especially among the large number of single-family houses built in the 1960s and 1970s...... that the use of this approach produced a better renovation with a larger energy saving. The initial evaluation helped the house owners identify a maintenance backlog, and the use of an independent advisor helped ensure quality throughout the process. Renovations are too often carried out for just one purpose......: maintenance, to update functions or to reduce energy consumption. But a lot can be gained by combining these efforts, which can reduce expenses for planning and execution and avoid doing things twice. Research for this thesis demonstrated this approach by carrying out a renovation based on maintenance...

  7. Sustainable Renovation of Residential Buildings and the Landlord/Tenant Dilemma

    DEFF Research Database (Denmark)

    Ástmarsson, Björn; Jensen, Per Anker; Maslesa, Esmir

    2013-01-01

    solutions can help solve the landlord/tenant dilemma in relation to sustainable renovation of residential buildings, and how the general awareness of sustainable renovation can be increased. Particular focus is on whether tools like energy performance contracting and energy labeling can help solve......The landlord/tenant dilemma arises when the interests of landlords and tenants misalign and is one of the greatest barriers hindering the development of sustainable renovation of residential buildings in Europe. The aim of this research is to investigate how regulatory changes and contractual...... be overcome with a package solution. In the Danish national context the package solution must consist of legislative changes, financial incentives and better dissemination of information. Therefore, an array of different tools must be integrated and used in cooperation to overcome the dilemma....

  8. Full-service concept for energy efficient renovation of single-family houses

    DEFF Research Database (Denmark)

    Vanhoutteghem, Lies; Tommerup, Henrik M.; Svendsen, Svend

    2011-01-01

    the solutions. Such one-stop-shops in the form of full-service providers of energy efficient renovation of single-family house are missing in the Nordic countries, although this service is vital to open up the market. As part of the Nordic research project `SuccesFamilies´ with the purpose to change...... houses. A one-stop-shop in the form of a full-service concept could be seen as a possibility to make it easy for the homeowner to comply with possible future requirements to realize far-reaching energy savings in connection with extensive renovations, provided that the building sector offers...... includes an ideal full-service concept and technical renovation solutions targeted to different types of single-family houses....

  9. Decision Support Model for Mosque Renovation and Rehabilitation (Case Study: Ten Mosques in Jakarta Barat, Indonesia)

    Science.gov (United States)

    Utama, D. N.; Triana, Y. S.; Iqbal, M. M.; Iksal, M.; Fikri, I.; Dharmawan, T.

    2018-03-01

    Mosque, for Muslim, is not only a place for daily worshipping, however as a center of culture as well. It is an important and valuable building to be well managed. For a responsible department or institution (such as Religion or Plan Department in Indonesia), to practically manage a lot of mosques is not simple task to handle. The challenge is in relation to data number and characteristic problems tackled. Specifically for renovating and rehabilitating the damaged mosques, a decision to determine the first damaged mosque priority to be renovated and rehabilitated is problematic. Through two types of optimization method, simulated-annealing and hill-climbing, a decision support model for mosque renovation and rehabilitation was systematically constructed. The method fuzzy-logic was also operated to establish the priority of eleven selected parameters. The constructed model is able to simulate an efficiency comparison between two optimization methods used and suggest the most objective decision coming from 196 generated alternatives.

  10. Improved perceived indoor environment in renovated and energy-retrofitted social housing

    DEFF Research Database (Denmark)

    Knudsen, Henrik Nellemose

    2017-01-01

    , noise from outside and too little daylight. The evaluation shows that it is possible to achieve a win-win situation, with both energy savings and improved perceived indoor environment. The evaluation also reveals that careful attention is needed to avoid introducing annoying noise from new technical......The purpose of the present study was, among other things, to evaluate how tenants perceived the indoor environment in renovated and energy-retrofitted social housing erected in the 1960s. Tenants answered a questionnaire to quantify problems and satisfaction with the indoor environment before...... and after the renovation work. A majority of tenants perceived the indoor environment improved for all parameters: temperature, draught, air quality, noise and daylight, after the renovation work. In particular, the tenants experienced fewer problems with too low temperature and draught during the winter...

  11. Ecotoxicological effects of highway and tunnel wash water runoff

    OpenAIRE

    Meland, Sondre

    2010-01-01

    In Norway, the traffic loadings have shown a substantial increase during the last decades. From 1948 to 2008 the transportation load has increased from 2.5 to 60.6 million passenger km. Hence, the ever increasing traffic has without doubt a significant negative effect on the environment. For example, highway runoffs typically contain a cocktail of both organic and inorganic contaminants being able to cause detrimental effects on the aquatic ecosystem. The present thesis, which is part of t...

  12. Survival of Salmonella spp. In Waste Egg Wash Water

    Science.gov (United States)

    The survival of salmonellae under various environmental conditions has been subject of numerous research studies. Due to low densities of these organisms in natural samples, laboratory or clinical cultures were used to ensure that the initial density of salmonellae was sufficien...

  13. Photocatalytic and electrochemical combined treatment of textile wash water

    International Nuclear Information System (INIS)

    Neelavannan, M.G.; Revathi, M.; Ahmed Basha, C.

    2007-01-01

    Various chemical and physical processes for treatment of textile effluent are not destructive but they only transfer the contaminants from one form to another. The presence of high concentration of organic dye and total dissolved solids (TDS) in the effluent that are not removed by biological treatment must be eliminated by an alternative method to the conventional ones is the advanced oxidation process (AOP). A procion blue dye effluent was treated by photo and electrochemical oxidation process as well as by combining photocatalytic degradation using TiO 2 suspensions. Chemical oxygen demand (COD) and colour removal can be used to follow the degradation of the organic pollutant. The effects of pH, current density, flow rate of effluent that passes into the reactor and supporting electrolyte were studied. Comparative studies were carried out on photocatalytic and electrochemical process to degrade the procion blue. The maximum COD reduction and colour removal were 96 and 100%, respectively. Photodegradation efficiency of dye was high when photolysis was carried out in the presence of 40 mg/l of TiO 2

  14. Evaluation of Water Consumption by Car Wash Facilities in Bauchi ...

    African Journals Online (AJOL)

    PROF HORSFALL

    Nigeria. 2Ofijidalillah Environmental Services, Ado Karu, Nasarawa State Nigeria ... were analysed using statistical method such as random sampling techniques and simple descriptive ... weekend, a long queue of cars is usually formed, all.

  15. Bench Scale Treatability Studies of Contaminated Soil Using Soil Washing Technique

    OpenAIRE

    Gupta, M. K.; Srivastava, R. K.; Singh, A. K.

    2010-01-01

    Soil contamination is one of the most widespread and serious environmental problems confronting both the industrialized as well as developing nations like India. Different contaminants have different physicochemical properties, which influence the geochemical reactions induced in the soils and may bring about changes in their engineering and environmental behaviour. Several technologies exist for the remediation of contaminated soil and water. In the present study soil washing technique using...

  16. Comparing effects of washing, thermal treatments and gamma irradiation on quality of spices

    International Nuclear Information System (INIS)

    Farag Zaied, S.E.A.; Aziz, N.H.; Ali, A.M.

    1996-01-01

    Samples of 5 selected spices, black pepper (Piper nigrum), fennel (Foeniculum vulgare), coriander (Coriandrum sativum) and anise (Pimpinella anisum) seeds, and turmeric (Curcuma longa) rhizomes, obtained from the local market, were washed with pure tap water then dried at room temperature, subjected to a thermal treatment at 70 degrees C for 15 minutes or exposed to a gamma radiation source (5.0 or 10 kGy). The treatments were evaluated using microbiological and chemical studies

  17. Process of recovery and reuse of the washing liquids from filters

    International Nuclear Information System (INIS)

    Flynn, G.C.

    1975-01-01

    The present invention relates to a backflush procedure intended for a repeated recovery and reuse of the liquid used for washing a 'pre-layer' filter. This type of filter is used for purifying the water of the steam generator circuit in electric energy generating plants equipped with steam turbines. Said 'pre-layer' filter can also be applied in the auxiliary facilities of electric energy generating plants, especially for treating the fuel ponds in nuclear reactors and for radioactive waste processing [fr

  18. Modelling Methods of Magnetohydrodynamic Phenomena Occurring in a Channel of the Device Used to Wash Out the Spent Automotive Catalyst by a Liquid Metal

    Directory of Open Access Journals (Sweden)

    Fornalczyk A.

    2016-06-01

    Full Text Available The recovery of precious metals is necessary for environmental and economic reasons. Spent catalysts from automotive industry containing precious metals are very attractive recyclable material as the devices have to be periodically renovated and eventually replaced. This paper presents the method of removing platinum from the spent catalytic converters applying lead as a collector metal in a device used to wash out by using mangetohydrodynamic stirrer. The article includes the description of the methods used for modeling of magnetohydrodynamic phenomena (coupled analysis of the electromagnetic, temperature and flow fields occurring in this particular device. The paper describes the general phenomena and ways of coupling the various physical fields for this type of calculation. The basic computational techniques with a discussion of their advantages and disadvantages are presented.

  19. La inversión en energías renovables en Argentina

    OpenAIRE

    Recalde, Marina

    2017-01-01

    En este artículo se analiza en qué medida los factores del entorno de la política energética de un país en desarrollo, tal como Argentina, determinan la evolución de la inversión en energías renovables. La baja calidad institucional del país ayuda a crear condiciones no propicias que contrarrestan el efecto de la política energética, reduciendo los incentivos para invertir en tecnologías renovables. Es necesario entonces mejorar las condiciones institucionales de los países en desarrollo para...

  20. Trusses Of Tensegrity Type In A Concept Of Train Station Renovation In Żary

    Directory of Open Access Journals (Sweden)

    Lechocka Paulina

    2015-09-01

    Full Text Available The first railway station in Żary was built in 1843 in Germany. After the Second World War and years of socialism in Poland the meaning of railway decreased and its technical condition deteriorated. Now the building needs renovation and change of function. Tensegrity structures may be useful in renovation of platforms shelter. They are strut and tie construction, in which there is self-stabilization between compressed and tensioned elements. Conception of new platform shelter is based on exemplary tensegrity module consist of three struts and nine cables (called „Simplex”. Tensegrity would make railway station more modern, but not cover its original elevation.

  1. Limitaciones para el desarrollo de energías renovables en Argentina

    OpenAIRE

    Marina Yesica Recalde; Daniel Hugo Bouille; Leónidas Osvaldo Girardin

    2015-01-01

    En las últimas décadas las energías renovables han cobrado impulso a nivel mundial con un significativo impacto sobre el desarrollo sustentable de las naciones. Si bien diferentes trabajos analizan la eficiencia de políticas e instrumentos para la promoción de dichas fuentes, la mayoría de las veces se deja de lado el análisis de cómo el contexto en el cual las políticas son implementadas determina su performance. En este trabajo se analiza el desarrollo de las energías renovables en el merca...

  2. Method for Developing and Assessing Holistic Energy Renovation of Multi-Storey Buildings

    DEFF Research Database (Denmark)

    Eriksen, Marlene Stenberg Hagen; Rode, Carsten; Bjarløv, Søren Peter

    A large part of the Danish building stock is from the post-war era, and thus there is an immense need for renovation within a few years. Also there is a persistent focus on energy use in buildings as it corresponds to about 40% of the total energy use in Denmark. However to secure durable solutions....... The assessment method is tested on two case buildings, and the assessment involves all relevant stakeholders including building owner, users, and caretakers. An element of the project looks to the development of new products and solutions for renovation for buildings. As part of the method, user involvement...

  3. Assessment of spatiotemporal variations in the fluvial wash-load component in the 21st century with regard to GCM climate change scenarios

    International Nuclear Information System (INIS)

    Mouri, Goro

    2015-01-01

    For stream water, in which a relationship exists between wash-load concentration and discharge, an estimate of fine-sediment delivery may be obtained from a traditional fluvial wash-load rating curve. Here, we demonstrate that the remaining wash-load material load can be estimated from a traditional empirical principle on a nationwide scale. The traditional technique was applied to stream water for the whole of Japan. Four typical GCMs were selected from the Coupled Model Intercomparison Project Phase 5 (CMIP5) ensemble to provide the driving fields for the following regional climate models to assess the wash-load component based on rating curves: the Model for Interdisciplinary Research on Climate (MIROC), the Meteorological Research Institute Atmospheric General Circulation Model (MRI-GCM), the Hadley Centre Global Environment Model (HadGEM) and the Geophysical Fluid Dynamics Laboratory (GFDL) climate model. The simulations consisted of an ensemble, including multiple physics configurations and different Representative Concentration Pathways (RCP2.6, RCP4.5 and RCP8.5), which was used to produce monthly datasets for the whole country of Japan. The impacts of future climate changes on fluvial wash load in Japanese stream water were based on the balance of changes in hydrological factors. The annual and seasonal variations of the fluvial wash load were assessed from the result of the ensemble analysis in consideration of the Greenhouse Gas (GHG) emission scenarios. The determined results for the amount of wash load increase range from approximately 20 to 110% in the 2040s, especially along part of the Pacific Ocean and the Sea of Japan regions. In the 2090s, the amount of wash load is projected to increase by more than 50% over the whole of Japan. The assessment indicates that seasonal variation is particularly important because the rainy and typhoon seasons, which include extreme events, are the dominant seasons. Because fluvial wash-load-component turbidity

  4. Assessment of spatiotemporal variations in the fluvial wash-load component in the 21st century with regard to GCM climate change scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Mouri, Goro, E-mail: mouri@rainbow.iis.u-tokyo.ac.jp

    2015-11-15

    For stream water, in which a relationship exists between wash-load concentration and discharge, an estimate of fine-sediment delivery may be obtained from a traditional fluvial wash-load rating curve. Here, we demonstrate that the remaining wash-load material load can be estimated from a traditional empirical principle on a nationwide scale. The traditional technique was applied to stream water for the whole of Japan. Four typical GCMs were selected from the Coupled Model Intercomparison Project Phase 5 (CMIP5) ensemble to provide the driving fields for the following regional climate models to assess the wash-load component based on rating curves: the Model for Interdisciplinary Research on Climate (MIROC), the Meteorological Research Institute Atmospheric General Circulation Model (MRI-GCM), the Hadley Centre Global Environment Model (HadGEM) and the Geophysical Fluid Dynamics Laboratory (GFDL) climate model. The simulations consisted of an ensemble, including multiple physics configurations and different Representative Concentration Pathways (RCP2.6, RCP4.5 and RCP8.5), which was used to produce monthly datasets for the whole country of Japan. The impacts of future climate changes on fluvial wash load in Japanese stream water were based on the balance of changes in hydrological factors. The annual and seasonal variations of the fluvial wash load were assessed from the result of the ensemble analysis in consideration of the Greenhouse Gas (GHG) emission scenarios. The determined results for the amount of wash load increase range from approximately 20 to 110% in the 2040s, especially along part of the Pacific Ocean and the Sea of Japan regions. In the 2090s, the amount of wash load is projected to increase by more than 50% over the whole of Japan. The assessment indicates that seasonal variation is particularly important because the rainy and typhoon seasons, which include extreme events, are the dominant seasons. Because fluvial wash-load-component turbidity

  5. A multi-methodology and sustainability-supporting framework for implementation and assessment of a holistic building renovation: Implementation and assessment of a holistic sustainable building renovation

    DEFF Research Database (Denmark)

    Kamari, Aliakbar

    . The research strategy employed in this thesis presents characteristics of two research types, namely the qualitative research approach, and the inter- or transdisciplinary research throughout mode 2. It therefore calls for an inductive research approach and involves an interpretive approach and comparative...... a deep building renovation and an ordinary one is a commitment to a holistic approach in which objectives/criteria are targeted early in the design stages and subsequently are considered for their interdependence throughout sustainability perspectives. A review of recent research has revealed...... is entitled RE-VALUE . The case study is Section 3 of Skovgårdsparken located in Brabrand, Denmark. It is a social housing complex (including nine blocks), and has been renovated by Brabrand Housing Association. The future of the research in this thesis concerns expanding of the TSBD framework for Building...

  6. High-rise build renovation - Colouring a high-rise building's facade; Renovation des Hochhauses Schoppi Spreitenbach. Farbigkeit einer Hochhausfassade

    Energy Technology Data Exchange (ETDEWEB)

    Enkerli, W.

    2008-07-01

    This illustrated article takes a look at the renovation of the 70-metres high, high-rise apartment building that forms an integral part of a large shopping centre in Spreitenbach, Switzerland. The buildings and their infrastructure, realised in 1970, were in need of renovation. The facade elements no longer met energy requirements and the shopping mall was to be extended to meet modern shopping needs. The article deals with the technical and aesthetic requirements placed on the facades. The colour concept for the venetian blinds integrated into the windows, which includes the use of 20 different shades of colour, is described. A total of 3,200 blinds are fitted. The removal of the old window elements and the fitting of the new facade elements is described and discussed.

  7. Application of washed MSWI fly ash in cement composites: long-term environmental impacts.

    Science.gov (United States)

    Yang, Zhenzhou; Tian, Sicong; Liu, Lili; Wang, Xidong; Zhang, Zuotai

    2018-04-01

    In the present study, long-term environmental impacts of compact and ground cement composites, in which 30 wt.% of cement was replaced by washed municipal solid wastes incineration (MSWI) fly ash, were investigated for use in building industry. Consecutive leaching tests over a time span of 180 days were performed in acid water, deionized water, and saline water, respectively, with the accumulative concentration of different elements determined in the leachate. Different leaching behaviors are observed among different potential toxic elements (PTEs). For instance, higher concentrations of V in the leachate were observed from the compact cement composites than those from the ground ones. The concentration of Ba in the leachate increased with the decrease of particle size of the cement composites, and an initial increase in the leaching efficiency of Sn was followed by a clear decline with the leaching time. In addition, kinetic study revealed that the leaching behaviors of potential toxic elements follow a second-order model. The results demonstrated that the addition of washed MSWI fly ash into cement can contribute to the attrition resistance, indicating that the washed MSWI fly ash could be a promising alternative for cement as supplementary building materials.

  8. Hand washing frequencies and procedures used in retail food services.

    Science.gov (United States)

    Strohbehn, Catherine; Sneed, Jeannie; Paez, Paola; Meyer, Janell

    2008-08-01

    Transmission of viruses, bacteria, and parasites to food by way of improperly washed hands is a major contributing factor in the spread of foodborne illnesses. Field observers have assessed compliance with hand washing regulations, yet few studies have included consideration of frequency and methods used by sectors of the food service industry or have included benchmarks for hand washing. Five 3-h observation periods of employee (n = 80) hand washing behaviors during menu production, service, and cleaning were conducted in 16 food service operations for a total of 240 h of direct observation. Four operations from each of four sectors of the retail food service industry participated in the study: assisted living for the elderly, childcare, restaurants, and schools. A validated observation form, based on 2005 Food Code guidelines, was used by two trained researchers. Researchers noted when hands should have been washed, when hands were washed, and how hands were washed. Overall compliance with Food Code recommendations for frequency during production, service, and cleaning phases ranged from 5% in restaurants to 33% in assisted living facilities. Procedural compliance rates also were low. Proposed benchmarks for the number of times hand washing should occur by each employee for each sector of food service during each phase of operation are seven times per hour for assisted living, nine times per hour for childcare, 29 times per hour for restaurants, and 11 times per hour for schools. These benchmarks are high, especially for restaurant employees. Implementation would mean lost productivity and potential for dermatitis; thus, active managerial control over work assignments is needed. These benchmarks can be used for training and to guide employee hand washing behaviors.

  9. Soil washing results for mixed waste pond soils at Hanford

    International Nuclear Information System (INIS)

    Gerber, M.A.; Freeman, H.D.; Baker, E.G.; Riemath, W.F.

    1991-01-01

    Soil washing technology was assessed as a means for remediating soil contaminated with mixed wastes primarily composed of heavy metals and radionuclides. The soils at the US Department of Energy's Hanford Site are considered suitable for soil washing because of their relatively low quantities of silt and clay. However, in a limited number of soil washing experiments using soils from different locations in the north pond of the 300 Area, the degree of decontamination achieved for the coarse fraction of the soil varied considerably. Part of this variation appears to be due to the presence of a discrete layer of contaminated sediment found in some of the samples

  10. The impact of WASH-1400 on reactor safety evaluation

    International Nuclear Information System (INIS)

    Tanguy, P.Y.

    1976-01-01

    Trends in reactor safety evaluation in France following the publication of WASH-1400 (the Rasmussen Report) are presented. What is called 'the meteorite case' is first schematically presented as follows: WASH-1400 shows nuclear risk equivalent to meteorite risk and reasonable corrections cannot make many orders of magnitude, consequently present safety rules are adequate. The very impact of WASH-1400 on safety approach is then discussed as for: assistance to deterministic safety analysis, introduction of probabilistic safety criteria, acceptable level of risk, and the use of results in research and reactor operating experience

  11. Patients' Hand Washing and Reducing Hospital-Acquired Infection.

    Science.gov (United States)

    Haverstick, Stacy; Goodrich, Cara; Freeman, Regi; James, Shandra; Kullar, Rajkiran; Ahrens, Melissa

    2017-06-01

    Hand hygiene is important to prevent hospital-acquired infections. Patients' hand hygiene is just as important as hospital workers' hand hygiene. Hospital-acquired infection rates remain a concern across health centers. To improve patients' hand hygiene through the promotion and use of hand washing with soap and water, hand sanitizer, or both and improve patients' education to reduce hospital-acquired infections. In August 2013, patients in a cardiothoracic postsurgical step-down unit were provided with individual bottles of hand sanitizer. Nurses and nursing technicians provided hand hygiene education to each patient. Patients completed a 6-question survey before the intervention, at hospital discharge and 1, 2, and 3 months after the intervention. Hospital-acquired infection data were tracked monthly by infection prevention staff. Significant correlations were found between hand hygiene and rates of infection with vancomycin-resistant enterococci ( P = .003) and methicillin-resistant Staphylococcus aureus ( P = .01) after the intervention. After the implementation of hand hygiene interventions, rates of both infections declined significantly and patients reported more staff offering opportunities for and encouraging hand hygiene. This quality improvement project demonstrates that increased hand hygiene compliance by patients can influence infection rates in an adult cardiothoracic step-down unit. The decreased infection rates and increased compliance with hand hygiene among the patients may be attributed to the implementation of patient education and the increased accessibility and use of hand sanitizer. ©2017 American Association of Critical-Care Nurses.

  12. Washing and caustic leaching of Hanford tank sludges

    International Nuclear Information System (INIS)

    Lumetta, G.J.; Rapko, B.M.; Colton, N.G.

    1994-01-01

    Methods are being developed to treat and dispose of large volumes of radioactive wastes stored in underground tanks at the U.S. Department of Energy's Hanford Site. The wastes will be partitioned into high-level waste (HLW) and low-level waste (LLW) fractions. The HLW will be vitrified into borosilicate glass and disposed of in a geologic repository, while the LLW will be immobilized in a glass matrix and will likely be disposed of by shallow burial at the Hanford Site. The wastes must be pretreated to reduce the volume of the HLW fraction, so that vitrification and disposal costs can be minimized. The current baseline process for pretreating Hanford tank sludges is to leach the sludge under caustic conditions, then remove the solubilized components of the sludge by water washing. Tests of this method have been performed with samples taken from several different tanks at Hanford. The results of these tests are presented in terms of the composition of the sludge before and after leaching. X-ray diffraction and scanning electron microscopy coupled with electron dispersive x-ray techniques have been used to identify the phases in the untreated and treated sludges

  13. SOIL WASHING TREATABILITY TESTS FOR PESTICIDE- CONTAMINATED SOIL

    Science.gov (United States)

    The 1987 Sand Creek Operable Unit 5 record of decision (ROD) identified soil washing as the selected technology to remediate soils contaminated with high levels of organochlorine pesticides, herbicides, and metals. Initial treatability tests conducted to assess the applicability...

  14. Overview of JGC soil washing and site stabilization (SWSS) concept

    International Nuclear Information System (INIS)

    Goetsch, S.; Fujimura, Y.; Sauda, K.; Yagi, T.; Suzuki, K.

    1991-01-01

    The JGC Soil Washing and Site Stabilization (SWSS) concept is to wash heavy metal and uranium-contaminated soils using well demonstrated techniques, and to follow that process with its innovative stabilization process, to fix the remaining contaminates within a stable matrix. In addition, the solution used to wash the soil is stripped of contaminates, so that it can be reused. This process reduces the total amount of wastes generated from washing the soil, since not only can the solution be reused, but often the extracted contaminates can be recovered for industrial use. The stabilization portion of the concept is based on a family of proprietary fixing agents which can render the remaining contaminates insoluble. These agents are significantly different from other (generally silicate) agents used for stabilizing contaminated soils in that they appear to bond more strongly to heavy metal contaminants than the silicate-based reagents, resulting in improved leach-rate performance when combined with bentonite or portland cement stabilization

  15. Why Is Hand Washing So Important? (For Parents)

    Science.gov (United States)

    ... hand washing a rule for everyone, especially: before eating and cooking after using the bathroom after cleaning around the house after touching animals, including family pets before and after visiting or ...

  16. Selected Hydrologic Data for Sand Cove Wash, Washington County, Utah

    National Research Council Canada - National Science Library

    Norton, Aaron; Susong, David D

    2004-01-01

    .... Hydrologic data collected in this study are described and listed in this report. Six boreholes were drilled in Sand Cove Wash to determine the vertical and spatial distribution of the alluvial deposits and their hydrologic...

  17. Documentation of a decision framework to support enhanced sludge washing

    International Nuclear Information System (INIS)

    Brothers, A.J.

    1995-01-01

    This document describes a proposed decision model that, if developed to its fullest, can provide a wide range of analysis options and insights to pretreatment/sludge washing alternatives. A recent decision has been made to terminate this work

  18. Influence of selected washing treatments and drying temperatures ...

    African Journals Online (AJOL)

    Influence of selected washing treatments and drying temperatures on ... with regard to the optimal retention of the crude protein and fat levels of the dried dagaa. ... are accessible to most of the households involved in dried fish processing.

  19. Interactive Configuration of High Performance Renovation of Apartment Buildings by the use of CSP

    DEFF Research Database (Denmark)

    Vareilles, E.; Thuesen, Christian; Falcon, M.

    2013-01-01

    of mid-rise (up to seven stories) apartment buildings. The renovation is based on external rectangular panels, always comprising insulation and cladding, and sometimes including, in addition, doors, windows or solar modules. The panels can be fixed directly onto the walls or onto a metal structure around...

  20. Performance Evaluation and Improvement of a Newly-Renovated Danish School Building (Retro-commissioning)

    DEFF Research Database (Denmark)

    Liu, Li; Georgieva, Viktoriya Vasileva; Zabusova, Diana

    2017-01-01

    In this study, we analyse and evaluate the energy performance of a Danish school building 4 years after its renovation. The structure of the following paper follows four phases, which include Planning, Investigation, Implementation and Hand-off. In the Planning phase, the objectives of the retro...

  1. Effectiveness of energy renovations : a reassessment based on actual consumption savings

    NARCIS (Netherlands)

    Filippidou, F.; Nieboer, N.E.T.; Visscher, H.J.

    2018-01-01

    Energy renovations offer unique opportunities to increase the energy efficiency of the built environment and for the existing housing stock; they are the most important solution. Usually, energy savings are based on modeling calculations. However, recent research has shown that the predicted

  2. [History of the renovation of the hôtel-Dieu of Bourges].

    Science.gov (United States)

    Gitton, Philippe

    2006-01-01

    From the 16th to the 20th century "hôtel-Dieu" was the main hospital in the Berry capital. In the 30's the mayor decided to renovate the building but in 1994 the construction of a new hospital--"Centre Hospitalier Jacques-Coeur"--freed the ancient building which became a historical centre for culture et tourism in the region.

  3. Financing New Technologies, Equipment/Furniture Replacement, and Building Renovation: A Survey Report.

    Science.gov (United States)

    Shirk, Gary M.

    1984-01-01

    Reports results of survey of methods used by 77 North American academic and public libraries to finance implementation of new technologies, replace equipment and furniture, and renovate buildings. Financing methods used, frequency of use, choice, and range of methods are discussed. Eight references and list of survey participants are appended.…

  4. Super-energy wrap-up model for renovation of standard wooden houses in Greenland?

    DEFF Research Database (Denmark)

    Bjarløv, Søren Peter; Vladyková, Petra

    2012-01-01

    This paper is based on the developed theoretical practice of super-insulation solution for renovation of exiting standard wooden houses in Greenland built from 1950s until 2006, more than half the building stock in Arctic Greenland. From various perspectives, the wrap-up system is evaluated as a ...

  5. Effect of renovating an office building on occupants' comfort and health

    DEFF Research Database (Denmark)

    Pejtersen, Jan; Brohus, H.; Hyldgaard, C. E.

    2001-01-01

    . Before the floor material was installed in the office building, a full-scale exposure experiment was performed in the laboratory. The new ventilation strategy and renovation of the HVAC system were selected on the basis of laboratory experiments on a full-scale mock-up of a cellular office. The severity...

  6. Renovating Alzheimer's: "Constructive" Reflections on the New Clinical and Research Diagnostic Guidelines

    Science.gov (United States)

    George, Daniel R.; Qualls, Sara H.; Camp, Cameron J.; Whitehouse, Peter J.

    2013-01-01

    The development of disease concepts for conditions such as Alzheimer's disease (AD) is an ongoing social process that evolves over time. The biomedical paradigm about AD that has informed our culture's understanding of brain aging for the past several decades is currently undergoing a major and timely renovation in the early 21st century. This…

  7. From demonstration projects to volume market : Market development for advanced housing renovation

    NARCIS (Netherlands)

    Mlecnik, E.; Prendergast, E.; Rodsjo, A.; Haavik, T.; Parker, P.

    2010-01-01

    How do we get from demonstration projects to a volume market for very low energy demand in advanced housing renovation? The contributors to this report have been working with this issue for many years. Some worked in both IEA SHC Task 28 Sustainable Housing (2000-2005) and in SHC Task 37 Advanced

  8. Energia Renovable para Centros de Salud Rurales (Renewable Energy for Rural Health Clinics)

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, T.; Olson, K.

    1999-07-28

    Esta es la primera de una serie de guias de aplicaciones que el Programa de Energia de Villas de NREL esta comisionando para acoplar sistemas comerciales renovables con aplicaciones rurales, incluyendo agua, escuelas rurales y micro empresas. La guia esta complementada por las actividades de desarrollo del Programa de Energia de Villas de NREL, proyectos pilotos internacionales y programas de visitas profesionales.

  9. Flood potential of Fortymile Wash and its principal southwestern tributaries, Nevada Test Site, Southern Nevada

    International Nuclear Information System (INIS)

    Squires, R.R.; Young, R.L.

    1984-01-01

    Flood hazards for a 9-mile reach of Fortymile Wash and its principal southwestern tributaries - Busted Butte, Drill Hole, and Yucca Washes - were evaluated to aid in determining possible sites for the storage of high-level radioactive wastes on the Nevada Test Site. Data from 12 peak-flow gaging stations adjacent to the Test Site were used to develop regression relations that would permit an estimation of the magnitude of the 100- and 500-year flood peaks (Q 100 and Q 500 ), in cubic feet per second. The resulting equations are: Q 100 = 482A 0 565 and Q 500 = 2200A 0 571 , where A is the tributary drainage area, in square miles. The estimate of the regional maximum flood was based on data from extreme floods elsewhere in Nevada and in surrounding states. Among seven cross sections on Fortymile Wash, the estimated maximum depths of the 100-year, 500-year, and regional maximum floods are 8, 11, and 29 feet, respectively. At these depths, flood water would remain within the deeply incised channel of the wash. Mean flow velocities would be as great as 9, 14, and 28 feet per second for the three respective flood magnitudes. The study shows that Busted Butte and Drill Hole Washes (9 and 11 cross sections, respectively) would have water depths of up to at least 4 feet and mean flow velocities of up to at least 8 feet per second during a 100-year flood. A 500-year flood would exceed stream-channel capacities at several places, with depths to 10 feet and mean flow velocities to 11 feet per second. The regional maximum flood would inundate sizeable areas in central parts of the two watersheds. At Yucca Wash (5 cross sections), the 100-year, 500-year, and regional maximum floods would remain within the stream channel. Maximum flood depths would be about 5, 9, and 23 feet and mean velocities about 9, 12, and 22 feet per second, respectively, for the three floods

  10. A Study on the Removal of Cesium in Soil Contaminated with Radiation Using a Soil Washing Process

    International Nuclear Information System (INIS)

    Park, Ukryang; Kim, Gyenam; Kim, Seungsoo; Park, Hyemin; Kim, Wansuk; Moon, Jaikwon

    2013-01-01

    The first principle is related with the washing process which is carried out to transfer the contaminated mass from the soil to water by dissolving it with a cleansing solution. The second is concerned with the size of the separation process which focuses on the reduction of the volume by separating the subject matters based on the different sizes of the soil. The complex agents used in the soil washing process include HCl, Oxalic acid, Citric acid, CaCl 2 , BaCl 2 , NH 4 NO 3 , and NaOH. It is known that the complex-forming capacity of such complex agents and radionuclides influences the decontamination from the soil. Also, since the forms of the chemical species related with the complex agents and the surface potential of the soil vary based on the changes of acidity observed in the cleansing solution, the level of acidity in the cleansing solution can be regarded as a factor that influences the decontamination. Therefore, in this study, H 2 SO 4 was selected as the complex agent and used to check the influence of the temperature when the subject contaminated soil was washed. Then, by applying the sieve grading process with a sieve-shaker, the size separation process was carried out to measure the level of radiation for each size. By washing the contaminated soil separated into different sizes with the complex agent H 2 SO 4 , the different removal tendencies for each size were considered. After selecting the complex agent H 2 SO 4 and checking the influence of temperature when the contaminated soil was washed based on the solid-liquid ratio of 1g:2ml, it was found that the heat washing process at a temperature of 95 .deg. C showed a higher level of efficiency for the removal of Cs compared to the case of the non-heat washing process. Also, according to the results given by the process of considering the different removal tendencies for each size based on the heat washing process after the sieve grading process was applied with the sieve-shaker prior for the size

  11. A Study on the Removal of Cesium in Soil Contaminated with Radiation Using a Soil Washing Process

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ukryang; Kim, Gyenam; Kim, Seungsoo; Park, Hyemin; Kim, Wansuk; Moon, Jaikwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The first principle is related with the washing process which is carried out to transfer the contaminated mass from the soil to water by dissolving it with a cleansing solution. The second is concerned with the size of the separation process which focuses on the reduction of the volume by separating the subject matters based on the different sizes of the soil. The complex agents used in the soil washing process include HCl, Oxalic acid, Citric acid, CaCl{sub 2}, BaCl{sub 2}, NH{sub 4}NO{sub 3}, and NaOH. It is known that the complex-forming capacity of such complex agents and radionuclides influences the decontamination from the soil. Also, since the forms of the chemical species related with the complex agents and the surface potential of the soil vary based on the changes of acidity observed in the cleansing solution, the level of acidity in the cleansing solution can be regarded as a factor that influences the decontamination. Therefore, in this study, H{sub 2}SO{sub 4} was selected as the complex agent and used to check the influence of the temperature when the subject contaminated soil was washed. Then, by applying the sieve grading process with a sieve-shaker, the size separation process was carried out to measure the level of radiation for each size. By washing the contaminated soil separated into different sizes with the complex agent H{sub 2}SO{sub 4}, the different removal tendencies for each size were considered. After selecting the complex agent H{sub 2}SO{sub 4} and checking the influence of temperature when the contaminated soil was washed based on the solid-liquid ratio of 1g:2ml, it was found that the heat washing process at a temperature of 95 .deg. C showed a higher level of efficiency for the removal of Cs compared to the case of the non-heat washing process. Also, according to the results given by the process of considering the different removal tendencies for each size based on the heat washing process after the sieve grading process was

  12. Membrane processes for the reuse of car washing wastewater

    OpenAIRE

    Deniz Uçar

    2018-01-01

    This study investigates alternative treatments of car wash effluents. The car wash wastewater was treated by settling, filtration, and membrane filtration processes. During settling, total solid concentration decreased rapidly within the first 2 hours and then remained constant. Chemical oxygen demand (COD) and conductivity were decreased by 10% and 4%, respectively. After settling, wastewater was filtered throughout a 100 μm filter. It was found that filtration had a negligible effect on COD...

  13. Purification of crude biodiesel using dry washing and membrane technologies

    OpenAIRE

    Atadashi, I.M.

    2015-01-01

    Purification of crude biodiesel is mandatory for the fuel to meet the strict international standard specifications for biodiesel. Therefore, this paper carefully analyzed recently published literatures which deal with the purification of biodiesel. As such, dry washing technologies and the most recent membrane biodiesel purification process have been thoroughly examined. Although purification of biodiesel using dry washing process involving magnesol and ion exchange resins provides high-quali...

  14. Fast pyrolysis of corn stover using ZnCl2: Effect of washing treatment on the furfural yield and solvent extraction of furfural

    International Nuclear Information System (INIS)

    Oh, Seung-Jin; Choi, Gyung-Goo; Kim, Joo-Sik

    2015-01-01

    To produce a bio-oil having a high concentration of furfural, corn stover was fast-pyrolyzed using ZnCl 2 in a fluidized bed reactor at 330–430 °C. The effects of various parameters such as reaction temperature, water- and acid-washing prior to pyrolysis, and ZnCl 2 content on the product and furfural yields were investigated. Moreover, solvent extraction was conducted using toluene at different mass ratios of bio-oil/toluene to recover furfural from the obtained bio-oil. The maximum yield of bio-oil was 59 wt%. The bio-oil mainly comprised acetic acid, α-hydroxyketones, and furfural. The maximum furfural yield was 11.5 wt% when the feed material was water-washed, impregnated with 18.5 wt% ZnCl 2 , and pyrolyzed. Although acid-washing removed alkali and alkaline earth metals much more efficiently than water-washing, water-washing was better than acid-washing for the furfural production. Toluene extraction was very effective to recover furfural from bio-oil. The maximum recovery rate (82%) was achieved at a bio-oil/toluene ratio of 1:4. - Highlights: • Corn stover pretreated and impregnated with ZnCl 2 was successfully pyrolyzed. • Furfural was recovered from bio-oil by extraction using toluene. • Water-washing was better than acid-washing for the furfural production. • The highest furfural yield was 11.5 wt% of the product. • The highest furfural recovery rate was 82%

  15. The source of groundwater and solutes to Many Devils Wash at a former uranium mill site in Shiprock, New Mexico

    Science.gov (United States)

    Robertson, Andrew J.; Ranalli, Anthony J.; Austin, Stephen A.; Lawlis, Bryan R.

    2016-04-21

    The Shiprock Disposal Site is the location of the former Navajo Mill (Mill), a uranium ore-processing facility, located on a terrace overlooking the San Juan River in the town of Shiprock, New Mexico. Following the closure of the Mill, all tailings and associated materials were encapsulated in a disposal cell built on top of the former Mill and tailings piles. The milling operations, conducted at the site from 1954 to 1968, created radioactive tailings and process-related wastes that are now found in the groundwater. Elevated concentrations of constituents of concern—ammonium, manganese, nitrate, selenium, strontium, sulfate, and uranium—have also been measured in groundwater seeps in the nearby Many Devils Wash arroyo, leading to the inference that these constituents originated from the Mill. These constituents have also been reported in groundwater that is associated with Mancos Shale, the bedrock that underlies the site. The objective of this report is to increase understanding of the source of water and solutes to the groundwater beneath Many Devils Wash and to establish the background concentrations for groundwater that is in contact with the Mancos Shale at the site. This report presents evidence on three working hypotheses: (1) the water and solutes in Many Devils Wash originated from the operations at the former Mill, (2) groundwater in deep aquifers is upwelling under artesian pressure to recharge the shallow groundwater beneath Many Devils Wash, and (3) the groundwater beneath Many Devils Wash originates as precipitation that infiltrates into the shallow aquifer system and discharges to Many Devils Wash in a series of springs on the east side of the wash. The solute concentrations in the shallow groundwater of Many Devils Wash would result from the interaction of the water and the Mancos Shale if the source of water was upwelling from deep aquifers or precipitation.In order to compare the groundwater from various wells to groundwater that has been

  16. Assessment of Flooring Renovations on African Elephant (Loxodonta africana) Behavior and Glucocorticoid Response

    Science.gov (United States)

    Boyle, Sarah A.; Roberts, Beth; Pope, Brittany M.; Blake, Margaret R.; Leavelle, Stephen E.; Marshall, Jennifer J.; Smith, Andrew; Hadicke, Amanda; Falcone, Josephine F.; Knott, Katrina; Kouba, Andrew J.

    2015-01-01

    Captive African (Loxodonta africana) and Asian (Elephas maximus) elephants can experience foot pathologies and arthritis. As a preventative measure against these pathologies and to alleviate the potential discomfort due to concrete substrates, some zoological institutions have renovated elephant housing to increase the amount of natural or shock-absorbent substrates. The objective of this study was to compare behavioral (diurnal and nocturnal) and glucorticoid (e.g., serum cortisol) responses of three female African elephants before, during, and after renovation to their indoor housing floor to assess whether renovations had short-term effects on the elephants’ behavior and stress physiology. Behavioral data were collected using scan-sampling methods, and activity budgets were constructed for each of the three elephants. In addition, the duration of all lying rest activities were recorded. Weekly serum cortisol concentrations were determined with enzyme immunoassay (EIA). Overall, eating was the most prevalent behavior exhibited outdoors during the day, while resting (either in a lying or standing position) were most common during the indoor, nocturnal periods. Although variation existed among the three elephants, all three females spent significantly more time walking and less time eating during the day after the completion of the renovations. The extent to which the three elephants exhibited nocturnal lying rest behavior varied among the elephants, with the oldest elephant exhibiting the least amount (an average of 13.2 ± 2.8% of the nightly behavioral scans) compared to the two younger elephants (an average of 34.5 ± 2.1% and 56.6 ± 2.8% of the nightly behavioral scans). There was a significant increase in lying rest behavior for one elephant and standing rest for a second elephant following renovations. Baseline cortisol concentrations prior to renovations were 3.0 ± 0.4 ng/ml, 4.5 ± 0.5 ng/ml, and 4.9 ± 0.5 ng/ml for the three elephants. Cortisol

  17. Assessment of Flooring Renovations on African Elephant (Loxodonta africana Behavior and Glucocorticoid Response.

    Directory of Open Access Journals (Sweden)

    Sarah A Boyle

    Full Text Available Captive African (Loxodonta africana and Asian (Elephas maximus elephants can experience foot pathologies and arthritis. As a preventative measure against these pathologies and to alleviate the potential discomfort due to concrete substrates, some zoological institutions have renovated elephant housing to increase the amount of natural or shock-absorbent substrates. The objective of this study was to compare behavioral (diurnal and nocturnal and glucorticoid (e.g., serum cortisol responses of three female African elephants before, during, and after renovation to their indoor housing floor to assess whether renovations had short-term effects on the elephants' behavior and stress physiology. Behavioral data were collected using scan-sampling methods, and activity budgets were constructed for each of the three elephants. In addition, the duration of all lying rest activities were recorded. Weekly serum cortisol concentrations were determined with enzyme immunoassay (EIA. Overall, eating was the most prevalent behavior exhibited outdoors during the day, while resting (either in a lying or standing position were most common during the indoor, nocturnal periods. Although variation existed among the three elephants, all three females spent significantly more time walking and less time eating during the day after the completion of the renovations. The extent to which the three elephants exhibited nocturnal lying rest behavior varied among the elephants, with the oldest elephant exhibiting the least amount (an average of 13.2 ± 2.8% of the nightly behavioral scans compared to the two younger elephants (an average of 34.5 ± 2.1% and 56.6 ± 2.8% of the nightly behavioral scans. There was a significant increase in lying rest behavior for one elephant and standing rest for a second elephant following renovations. Baseline cortisol concentrations prior to renovations were 3.0 ± 0.4 ng/ml, 4.5 ± 0.5 ng/ml, and 4.9 ± 0.5 ng/ml for the three elephants

  18. Particle Separation of Non-Decontamination Soil using Attrition and Washing

    International Nuclear Information System (INIS)

    Koo, Daeseo; Sung, Hyun-Hee; Kim, Seung-Soo; Hong, Sang Bum; Seo, Bum Kyoung; Choi, Jong-Won

    2017-01-01

    In this study, to improve the decontamination efficiency of uranium soil, a preliminary experiment on the particle separation of non-decontamination soil was carried out using attrition and washing. The characteristics of the attrition and washing system are investigated. A conditional experiment on particle separation of non-decontamination soil will be performed. A preliminary experiment on the particle separation of non-decontamination soil was carried out to improve the decontamination efficiency of uranium soil. This experiment was performed with the ratio of soil to water (1:4) for the particle separation of non-decontamination soil. The operations of all equipment such as attrition scrubber, ultrasonic reaction, vibrating screen, and hydro-cyclone were conducted and confirmed. In the future, the additional experiments will be conducted for optimal experimental condition.

  19. A comparison of ethanol and methane fermentation of currant-and sultana-washing wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Athanasopoulos, Nikolaos (Patras Univ. (Greece). Dept. of Chemistry)

    1994-01-01

    Wastewater from currant- and sultana-washing processes was successfully treated in an ethanol fermenter at 33[sup o]C; the pH of the wash water was controlled at 2.8; the reducing sugar content was 38.8 g/litre; commercial baker's yeast was used as inoculum at a concentration of 2.5 g/litre; formaldehyde at a concentration of 150 mg/litre was used as antiseptic; the ethanol yield was 70.6% of the theoretical value in 24 h; the COD removal after a single distillation was 84%. The overall economics of ethanol fermentation are very promising compared to methane fermentation. (author)

  20. Chlorides behavior in raw fly ash washing experiments

    International Nuclear Information System (INIS)

    Zhu Fenfen; Takaoka, Masaki; Oshita, Kazuyuki; Kitajima, Yoshinori; Inada, Yasuhiro; Morisawa, Shinsuke; Tsuno, Hiroshi

    2010-01-01

    Chloride in fly ash from municipal solid waste incinerators (MSWIs) is one of the obstructive substances in recycling fly ash as building materials. As a result, we have to understand the behavior of chlorides in recycling process, such as washing. In this study, we used X-ray absorption near edge structure (XANES) and X-ray diffraction (XRD) to study the chloride behavior in washed residue of raw fly ash (RFA). We found that a combination of XRD and XANES, which is to use XRD to identify the situation of some compounds first and then process XANES data, was an effective way to explain the chlorides behavior in washing process. Approximately 15% of the chlorine in RFA was in the form of NaCl, 10% was in the form of KCl, 51% was CaCl 2 , and the remainder was in the form of Friedel's salt. In washing experiments not only the mole percentage but also the amount of soluble chlorides including NaCl, KCl and CaCl 2 decreases quickly with the increase of liquid to solid (L/S) ratio or washing frequency. However, those of insoluble chlorides decrease slower. Moreover, Friedel's salt and its related compound (11CaO.7Al 2 O 3 .CaCl 2 ) were reliable standards for the insoluble chlorides in RFA, which are strongly related to CaCl 2 . Washing of RFA promoted the release of insoluble chlorides, most of which were in the form of CaCl 2 .