  1. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample.

    Science.gov (United States)

    Lee, Kil Yong; Burnett, William C

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 °C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods.

  2. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample

    International Nuclear Information System (INIS)

    Kil Yong Lee; Burnett, W.C.

    2013-01-01

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 deg C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods. (author)

  3. Fast and effective determination of strontium-90 in high volumes water samples

    International Nuclear Information System (INIS)

    Basarabova, B.; Dulanska, S.

    2014-01-01

    A simple and fast method was developed for determination of 90 Sr in high volumes of water samples from vicinity of nuclear power facilities. Samples were taken from the environment near Nuclear Power Plants in Jaslovske Bohunice and Mochovce in Slovakia. For determination of 90 Sr was used solid phase extraction using commercial sorbent Analig R Sr-01 from company IBC Advanced Technologies, Inc.. Determination of 90 Sr was performed with dilute solution of HNO 3 (1.5-2 M) and also tested in base medium with NaOH. For elution of 90 Sr was used eluent EDTA with pH in range 8-9. To achieve fast determination, automation was applied, which brings significant reduction of separation time. Concentration of water samples with evaporation was not necessary. Separation was performed immediately after filtration of analyzed samples. The aim of this study was development of less expensive, time unlimited and energy saving method for determination of 90 Sr in comparison with conventional methods. Separation time for fast-flow with volume of 10 dm 3 of water samples was 3.5 hours (flow-rate approximately 3.2 dm 3 / 1 hour). Radiochemical strontium yield was traced by using radionuclide 85 Sr. Samples were measured with HPGe detector (High-purity Germanium detector) at energy E φ = 514 keV. By using Analig R Sr-01 yields in range 72 - 96 % were achieved. Separation based on solid phase extraction using Analig R Sr-01 employing utilization of automation offers new, fast and effective method for determination of 90 Sr in water matrix. After ingrowth of yttrium samples were measured by Liquid Scintillation Spectrometer Packard Tricarb 2900 TR with software Quanta Smart. (authors)

  4. Rapid determination of benzene derivatives in water samples by trace volume solvent DLLME prior to GC-FID

    Energy Technology Data Exchange (ETDEWEB)

    Diao, Chun Peng; Wei, Chao Hai; Feng, Chun Hua [South China Univ. of Technology, Guangzhou Higher Education Mega Center (China). College of Environmental Science and Engineering; Guangdong Regular Higher Education Institutions, Guangzhou (China). Key Lab. of Environmental Protection and Eco-Remediation

    2012-05-15

    An inexpensive, simple and environmentally friendly method based on dispersive liquid liquid microextraction (DLLME) for rapid determination of benzene derivatives in water samples was proposed. A significant improvement of DLLME procedure was achieved. Trace volume ethyl acetate (60 {mu}L) was exploited as dispersion solvent instead of common ones such as methanol and acetone, the volume of which was more than 0.5 mL, and the organic solvent required in DLLME was reduced to a great extent. Only 83-{mu}L organic solvent was consumed in the whole analytic process and the preconcentration procedure was less than 10 min. The advantageous approach coupled with gas chromatograph-flame ionization detector was proposed for the rapid determination of benzene, toluene, ethylbenzene and xylene isomers in water samples. Results showed that the proposed approach was an efficient method for rapid determination of benzene derivatives in aqueous samples. (orig.)

  5. Radioiodine enrichment of large-volume water samples in order to increase the sensitivity of detection

    International Nuclear Information System (INIS)

    Behrens, H.

    1981-01-01

    The method can be employed in the decontamination of water and waste water, separating the I from acid solution at silvered activated carbon. It was tested as an enrichment method in radioecological investigations of the I-131 contents in surface and ground water. (DG) [de

  6. Water pollution screening by large-volume injection of aqueous samples and application to GC/MS analysis of a river Elbe sample

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, S.; Efer, J.; Engewald, W. [Leipzig Univ. (Germany). Inst. fuer Analytische Chemie

    1997-03-01

    The large-volume sampling of aqueous samples in a programmed temperature vaporizer (PTV) injector was used successfully for the target and non-target analysis of real samples. In this still rarely applied method, e.g., 1 mL of the water sample to be analyzed is slowly injected direct into the PTV. The vaporized water is eliminated through the split vent. The analytes are concentrated onto an adsorbent inside the insert and subsequently thermally desorbed. The capability of the method is demonstrated using a sample from the river Elbe. By means of coupling this method with a mass selective detector in SIM mode (target analysis) the method allows the determination of pollutants in the concentration range up to 0.01 {mu}g/L. Furthermore, PTV enrichment is an effective and time-saving method for non-target analysis in SCAN mode. In a sample from the river Elbe over 20 compounds were identified. (orig.) With 3 figs., 2 tabs.

  7. Heterogeneous asymmetric recombinase polymerase amplification (haRPA) for rapid hygiene control of large-volume water samples.

    Science.gov (United States)

    Elsäßer, Dennis; Ho, Johannes; Niessner, Reinhard; Tiehm, Andreas; Seidel, Michael

    2018-04-01

    Hygiene of drinking water is periodically controlled by cultivation and enumeration of indicator bacteria. Rapid and comprehensive measurements of emerging pathogens are of increasing interest to improve drinking water safety. In this study, the feasibility to detect bacteriophage PhiX174 as a potential indicator for virus contamination in large volumes of water is demonstrated. Three consecutive concentration methods (continuous ultrafiltration, monolithic adsorption filtration, and centrifugal ultrafiltration) were combined to concentrate phages stepwise from 1250 L drinking water into 1 mL. Heterogeneous asymmetric recombinase polymerase amplification (haRPA) is applied as rapid detection method. Field measurements were conducted to test the developed system for hygiene online monitoring under realistic conditions. We could show that this system allows the detection of artificial contaminations of bacteriophage PhiX174 in drinking water pipelines. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Solid phase extraction of large volume of water and beverage samples to improve detection limits for GC-MS analysis of bisphenol A and four other bisphenols.

    Science.gov (United States)

    Cao, Xu-Liang; Popovic, Svetlana

    2018-01-01

    Solid phase extraction (SPE) of large volumes of water and beverage products was investigated for the GC-MS analysis of bisphenol A (BPA), bisphenol AF (BPAF), bisphenol F (BPF), bisphenol E (BPE), and bisphenol B (BPB). While absolute recoveries of the method were improved for water and some beverage products (e.g. diet cola, iced tea), breakthrough may also have occurred during SPE of 200 mL of other beverages (e.g. BPF in cola). Improvements in method detection limits were observed with the analysis of large sample volumes for all bisphenols at ppt (pg/g) to sub-ppt levels. This improvement was found to be proportional to sample volumes for water and beverage products with less interferences and noise levels around the analytes. Matrix effects and interferences were observed during SPE of larger volumes (100 and 200 mL) of the beverage products, and affected the accurate analysis of BPF. This improved method was used to analyse bisphenols in various beverage samples, and only BPA was detected, with levels ranging from 0.022 to 0.030 ng/g for products in PET bottles, and 0.085 to 0.32 ng/g for products in cans.

  9. Developing Water Sampling Standards

    Science.gov (United States)

    Environmental Science and Technology, 1974

    1974-01-01

    Participants in the D-19 symposium on aquatic sampling and measurement for water pollution assessment were informed that determining the extent of waste water stream pollution is not a cut and dry procedure. Topics discussed include field sampling, representative sampling from storm sewers, suggested sampler features and application of improved…

  10. Reactor water sampling device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo.

    1992-01-01

    The present invention concerns a reactor water sampling device for sampling reactor water in an in-core monitor (neutron measuring tube) housing in a BWR type reactor. The upper end portion of a drain pipe of the reactor water sampling device is attached detachably to an in-core monitor flange. A push-up rod is inserted in the drain pipe vertically movably. A sampling vessel and a vacuum pump are connected to the lower end of the drain pipe. A vacuum pump is operated to depressurize the inside of the device and move the push-up rod upwardly. Reactor water in the in-core monitor housing flows between the drain pipe and the push-up rod and flows into the sampling vessel. With such a constitution, reactor water in the in-core monitor housing can be sampled rapidly with neither opening the lid of the reactor pressure vessel nor being in contact with air. Accordingly, operator's exposure dose can be reduced. (I.N.)

  11. A propidium monoazide–quantitative PCR method for the detection and quantification of viable Enterococcus faecalis in large-volume samples of marine waters

    KAUST Repository

    Salam, Khaled W.; El-Fadel, Mutasem E.; Barbour, Elie K.; Saikaly, Pascal

    2014-01-01

    The development of rapid detection assays of cell viability is essential for monitoring the microbiological quality of water systems. Coupling propidium monoazide with quantitative PCR (PMA-qPCR) has been successfully applied in different studies for the detection and quantification of viable cells in small-volume samples (0.25-1.00 mL), but it has not been evaluated sufficiently in marine environments or in large-volume samples. In this study, we successfully integrated blue light-emitting diodes for photoactivating PMA and membrane filtration into the PMA-qPCR assay for the rapid detection and quantification of viable Enterococcus faecalis cells in 10-mL samples of marine waters. The assay was optimized in phosphate-buffered saline and seawater, reducing the qPCR signal of heat-killed E. faecalis cells by 4 log10 and 3 log10 units, respectively. Results suggest that high total dissolved solid concentration (32 g/L) in seawater can reduce PMA activity. Optimal PMA-qPCR standard curves with a 6-log dynamic range and detection limit of 102 cells/mL were generated for quantifying viable E. faecalis cells in marine waters. The developed assay was compared with the standard membrane filter (MF) method by quantifying viable E. faecalis cells in seawater samples exposed to solar radiation. The results of the developed PMA-qPCR assay did not match that of the standard MF method. This difference in the results reflects the different physiological states of E. faecalis cells in seawater. In conclusion, the developed assay is a rapid (∼5 h) method for the quantification of viable E. faecalis cells in marine recreational waters, which should be further improved and tested in different seawater settings. © 2014 Springer-Verlag Berlin Heidelberg.

  12. A propidium monoazide–quantitative PCR method for the detection and quantification of viable Enterococcus faecalis in large-volume samples of marine waters

    KAUST Repository

    Salam, Khaled W.

    2014-08-23

    The development of rapid detection assays of cell viability is essential for monitoring the microbiological quality of water systems. Coupling propidium monoazide with quantitative PCR (PMA-qPCR) has been successfully applied in different studies for the detection and quantification of viable cells in small-volume samples (0.25-1.00 mL), but it has not been evaluated sufficiently in marine environments or in large-volume samples. In this study, we successfully integrated blue light-emitting diodes for photoactivating PMA and membrane filtration into the PMA-qPCR assay for the rapid detection and quantification of viable Enterococcus faecalis cells in 10-mL samples of marine waters. The assay was optimized in phosphate-buffered saline and seawater, reducing the qPCR signal of heat-killed E. faecalis cells by 4 log10 and 3 log10 units, respectively. Results suggest that high total dissolved solid concentration (32 g/L) in seawater can reduce PMA activity. Optimal PMA-qPCR standard curves with a 6-log dynamic range and detection limit of 102 cells/mL were generated for quantifying viable E. faecalis cells in marine waters. The developed assay was compared with the standard membrane filter (MF) method by quantifying viable E. faecalis cells in seawater samples exposed to solar radiation. The results of the developed PMA-qPCR assay did not match that of the standard MF method. This difference in the results reflects the different physiological states of E. faecalis cells in seawater. In conclusion, the developed assay is a rapid (∼5 h) method for the quantification of viable E. faecalis cells in marine recreational waters, which should be further improved and tested in different seawater settings. © 2014 Springer-Verlag Berlin Heidelberg.

  13. Trace analysis of isothiazolinones in water samples by large-volume direct injection liquid chromatography tandem mass spectrometry

    NARCIS (Netherlands)

    Speksnijder, P.; van Ravestijn, J.; de Voogt, P.

    2010-01-01

    Isothiazolinones are used as preservatives, biocides and disinfectants in a variety of industrial and domestic applications. Some of the isothiazolinones are difficult to isolate from water due their high polarity. A sensitive and selective analytical method was developed and optimized for the

  14. Determination of environmental levels of 239240Pu, 241Am, 137Cs, and 90Sr in large volume sea water samples

    International Nuclear Information System (INIS)

    Sutton, D.C.; Calderon, G.; Rosa, W.

    1976-06-01

    A method is reported for the determination of environmental levels of 239 240 Pu and 241 Am in approximately 60-liter size samples of seawater. 137 Cs and 90 Sr were also separated and determined from the same samples. The samples were collected at the sea surface and at various depths in the oceans through the facilities of the Woods Hole Oceanographic Institution. Plutonium and americium were separated from the seawater by iron hydroxide scavenging then treated with a mixture of nitric, hydrochloric, and perchloric acids. A series of anion exchange separations were used to remove interferences and purify plutonium and americium; then each was electroplated on platinum disks and measured by solid state alpha particle spectrometry. The overall chemical yields averaged 62 +- 9 and 69 +- 14 percent for 236 Pu, and 243 Am tracers, respectively. Following the iron hydroxide scavenge of the transuranics, cesium was removed from the acidified seawater matrix by adsorption onto ammonium phosphomolybdate. Cesium carrier and 137 Cs isolation was effected by ion exchange and precipitations were made using chloroplatinic acid. The samples were weighed to determine overall chemical yield then beta counted. Cesium recoveries averaged 75 +- 5 percent. After cesium was removed from the seawater matrix, the samples were neutralized with sodium hydroxide and ammonium carbonate was added to precipitate 85 Sr tracer and the mixed alkaline earth carbonates. Strontium was separated as the nitrate and scavenged by chromate and hydroxide precipitations. Yttrium-90 was allowed to build up for two weeks, then milked and precipitated as the oxalate, weighed, and beta counted. The overall chemical yields of 85 Sr tracer averaged 84 +- 16 percent. The recovery of the yttrium oxalate precipitates averaged 96 +- 3 percent

  15. Uranium in US surface, ground, and domestic waters. Volume 2

    International Nuclear Information System (INIS)

    Drury, J.S.; Reynolds, S.; Owen, P.T.; Ross, R.H.; Ensminger, J.T.

    1981-04-01

    The report Uranium in US Surface, Ground, and Domestic Waters comprises four volumes. Volumes 2, 3, and 4 contain data characterizing the location, sampling date, type, use, and uranium conentrations of 89,994 individual samples presented in tabular form. The tabular data in volumes 2, 3, and 4 are summarized in volume 1 in narrative form and with maps and histograms

  16. Analysis of water and soil from the wetlands of Upper Three Runs Creek. Volume 2A, Analytical data packages September--October 1991 sampling

    Energy Technology Data Exchange (ETDEWEB)

    Haselow, L.A.; Rogers, V.A. [Westinghouse Savannah River Co., Aiken, SC (United States); Riordan, C.J. [Metcalf and Eddy, Inc. (United States); Eidson, G.W.; Herring, M.K. [Normandeau Associates, Inc. (United States)

    1992-08-01

    Shallow water and soils along Upper Three Runs Creek (UTRC) and associated wetlands between SRS Road F and Cato Road were sampled for nonradioactive and radioactive constituents. The sampling program is associated with risk evaluations being performed for various regulatory documents in these areas of the Savannah River Site (SRS). WSRC selected fifty sampling sites bordering the Mixed Waste Management Facility (MWMF), F- and H-Area Seepage Basins (FHSB), and the Sanitary Landfill (SL). The analytical results from this study provided information on the water and soil quality in UTRC and its associated wetlands. The analytical results from this investigation indicated that the primary constituents and radiological indicators detected in the shallow water and soils were tritium, gross alpha, radium 226, total radium and strontium 90. This investigation involved the collection of shallow water samples during the Fall of 1991 and the Spring of 1992 at fifty (50) sampling locations. Sampling was performed during these periods to incorporate high and low water table periods. Samples were collected from three sections along UTRC denoted as Phase I (MWMF), Phase II (FHSB) and Phase III (SL). One vibracored soil sample was also collected in each phase during the Fall of 1991. This document is compiled solely of experimental data obtained from the sampling procedures.

  17. Analysis of water and soil from the wetlands of Upper Three Runs Creek. Volume 2B: Analytical data packages, January--February 1992 sampling

    Energy Technology Data Exchange (ETDEWEB)

    Haselow, L.A.; Rogers, V.A. [Westinghouse Savannah River Co., Aiken, SC (United States); Riordan, C.J. [Metcalf and Eddy (United States); Eidson, G.W.; Herring, M.K. [Normandeau Associates, Inc., Aiken, SC (United States)

    1992-08-01

    Shallow water and soils along Upper Three Runs Creek (UTRC) and associated wetlands between SRS Road F and Cato Road were sampled for nonradioactive and radioactive constituents. The sampling program is associated with risk evaluations being performed for various regulatory documents in these areas of the Savannah River Site (SRS). WSRC selected fifty sampling sites bordering the Mixed Waste Management Facility (MWMF), F- and H-Area Seepage Basins (FHSB), and the Sanitary Landfill (SL). The analytical results from this study provided information on the water and soil quality in UTRC and its associated wetlands. The analytical results from this investigation indicated that the primary constituents and radiological indicators detected in the shallow water and soils were tritium, gross alpha, radium 226, total radium and strontium 90. This investigation involved the collection of shallow water samples during the Fall of 1991 and the Spring of 1992 at fifty (50) sampling locations. Sampling was performed during these periods to incorporate high and low water table periods. Samples were collected from three sections along UTRC denoted as Phase I (MWMF), Phase II (FHSB) and Phase III (SL). One vibracored soil sample was also collected in each phase during the Fall of 1991. This document is compiled of experimental data obtained from the sampling procedures.

  18. Zirconia coated stir bar sorptive extraction combined with large volume sample stacking capillary electrophoresis-indirect ultraviolet detection for the determination of chemical warfare agent degradation products in water samples.

    Science.gov (United States)

    Li, Pingjing; Hu, Bin; Li, Xiaoyong

    2012-07-20

    In this study, a sensitive, selective and reliable analytical method by combining zirconia (ZrO₂) coated stir bar sorptive extraction (SBSE) with large volume sample stacking capillary electrophoresis-indirect ultraviolet (LVSS-CE/indirect UV) was developed for the direct analysis of chemical warfare agent degradation products of alkyl alkylphosphonic acids (AAPAs) (including ethyl methylphosphonic acid (EMPA) and pinacolyl methylphosphonate (PMPA)) and methylphosphonic acid (MPA) in environmental waters. ZrO₂ coated stir bar was prepared by adhering nanometer-sized ZrO₂ particles onto the surface of stir bar with commercial PDMS sol as adhesion agent. Due to the high affinity of ZrO₂ to the electronegative phosphonate group, ZrO₂ coated stir bars could selectively extract the strongly polar AAPAs and MPA. After systematically optimizing the extraction conditions of ZrO₂-SBSE, the analytical performance of ZrO₂-SBSE-CE/indirect UV and ZrO₂-SBSE-LVSS-CE/indirect UV was assessed. The limits of detection (LODs, at a signal-to-noise ratio of 3) obtained by ZrO₂-SBSE-CE/indirect UV were 13.4-15.9 μg/L for PMPA, EMPA and MPA. The relative standard deviations (RSDs, n=7, c=200 μg/L) of the corrected peak area for the target analytes were in the range of 6.4-8.8%. Enhancement factors (EFs) in terms of LODs were found to be from 112- to 145-fold. By combining ZrO₂ coating SBSE with LVSS as a dual preconcentration strategy, the EFs were magnified up to 1583-fold, and the LODs of ZrO₂-SBSE-LVSS-CE/indirect UV were 1.4, 1.2 and 3.1 μg/L for PMPA, EMPA, and MPA, respectively. The RSDs (n=7, c=20 μg/L) were found to be in the range of 9.0-11.8%. The developed ZrO₂-SBSE-LVSS-CE/indirect UV method has been successfully applied to the analysis of PMPA, EMPA, and MPA in different environmental water samples, and the recoveries for the spiked water samples were found to be in the range of 93.8-105.3%. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Water sampling techniques for continuous monitoring of pesticides in water

    Directory of Open Access Journals (Sweden)

    Šunjka Dragana

    2017-01-01

    Full Text Available Good ecological and chemical status of water represents the most important aim of the Water Framework Directive 2000/60/EC, which implies respect of water quality standards at the level of entire river basin (2008/105/EC and 2013/39/EC. This especially refers to the control of pesticide residues in surface waters. In order to achieve the set goals, a continuous monitoring program that should provide a comprehensive and interrelated overview of water status should be implemented. However, it demands the use of appropriate analysis techniques. Until now, the procedure for sampling and quantification of residual pesticide quantities in aquatic environment was based on the use of traditional sampling techniques that imply periodical collecting of individual samples. However, this type of sampling provides only a snapshot of the situation in regard to the presence of pollutants in water. As an alternative, the technique of passive sampling of pollutants in water, including pesticides has been introduced. Different samplers are available for pesticide sampling in surface water, depending on compounds. The technique itself is based on keeping a device in water over a longer period of time which varies from several days to several weeks, depending on the kind of compound. In this manner, the average concentrations of pollutants dissolved in water during a time period (time-weighted average concentrations, TWA are obtained, which enables monitoring of trends in areal and seasonal variations. The use of these techniques also leads to an increase in sensitivity of analytical methods, considering that pre-concentration of analytes takes place within the sorption medium. However, the use of these techniques for determination of pesticide concentrations in real water environments requires calibration studies for the estimation of sampling rates (Rs. Rs is a volume of water per time, calculated as the product of overall mass transfer coefficient and area of

  20. National comparison on volume sample activity measurement methods

    International Nuclear Information System (INIS)

    Sahagia, M.; Grigorescu, E.L.; Popescu, C.; Razdolescu, C.

    1992-01-01

    A national comparison on volume sample activity measurements methods may be regarded as a step toward accomplishing the traceability of the environmental and food chain activity measurements to national standards. For this purpose, the Radionuclide Metrology Laboratory has distributed 137 Cs and 134 Cs water-equivalent solid standard sources to 24 laboratories having responsibilities in this matter. Every laboratory has to measure the activity of the received source(s) by using its own standards, equipment and methods and report the obtained results to the organizer. The 'measured activities' will be compared with the 'true activities'. A final report will be issued, which plans to evaluate the national level of precision of such measurements and give some suggestions for improvement. (Author)

  1. Radon measurement in Malaysia water samples

    International Nuclear Information System (INIS)

    Ibrahim, A.B.; Rosli Mahat; Yusof Md Amin

    1995-01-01

    This paper reported the results of the measurement of radon in local water. The water samples collected were rainwater, river water, seawater, well water or ground water at area of State of Selangor and Kuala Lumpur. The samples were collected in scintillation cell ZnS(Ag) through Radon Degassing Unit RDU 200. Alpha activity was counted with scintillation counters RD 200 at energy 5.5 MeV. (author)

  2. Volume Ray Casting with Peak Finding and Differential Sampling

    KAUST Repository

    Knoll, A.; Hijazi, Y.; Westerteiger, R.; Schott, M.; Hansen, C.; Hagen, H.

    2009-01-01

    classification. In this paper, we introduce a method for rendering such features by explicitly solving for isovalues within the volume rendering integral. In addition, we present a sampling strategy inspired by ray differentials that automatically matches

  3. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  4. Determination of Phthalates in Drinking Water Samples

    African Journals Online (AJOL)

    user

    successfully applied to the analysis of phthalate esters contamination in bottled drinking water samples. ... esters are used in the manufacturing of polyvinyl chloride. (PVC). ... water, soil, air, food products and the human body. (Castillo et al.

  5. Water sample-collection and distribution system

    Science.gov (United States)

    Brooks, R. R.

    1978-01-01

    Collection and distribution system samples water from six designated stations, filtered if desired, and delivers it to various analytical sensors. System may be controlled by Water Monitoring Data Acquisition System or operated manually.

  6. A Comparison of Soil-Water Sampling Techniques

    Science.gov (United States)

    Tindall, J. A.; Figueroa-Johnson, M.; Friedel, M. J.

    2007-12-01

    The representativeness of soil pore water extracted by suction lysimeters in ground-water monitoring studies is a problem that often confounds interpretation of measured data. Current soil water sampling techniques cannot identify the soil volume from which a pore water sample is extracted, neither macroscopic, microscopic, or preferential flowpath. This research was undertaken to compare values of extracted suction lysimeters samples from intact soil cores with samples obtained by the direct extraction methods to determine what portion of soil pore water is sampled by each method. Intact soil cores (30 centimeter (cm) diameter by 40 cm height) were extracted from two different sites - a sandy soil near Altamonte Springs, Florida and a clayey soil near Centralia in Boone County, Missouri. Isotopically labeled water (O18? - analyzed by mass spectrometry) and bromide concentrations (KBr- - measured using ion chromatography) from water samples taken by suction lysimeters was compared with samples obtained by direct extraction methods of centrifugation and azeotropic distillation. Water samples collected by direct extraction were about 0.25 ? more negative (depleted) than that collected by suction lysimeter values from a sandy soil and about 2-7 ? more negative from a well structured clayey soil. Results indicate that the majority of soil water in well-structured soil is strongly bound to soil grain surfaces and is not easily sampled by suction lysimeters. In cases where a sufficient volume of water has passed through the soil profile and displaced previous pore water, suction lysimeters will collect a representative sample of soil pore water from the sampled depth interval. It is suggested that for stable isotope studies monitoring precipitation and soil water, suction lysimeter should be installed at shallow depths (10 cm). Samples should also be coordinated with precipitation events. The data also indicate that each extraction method be use to sample a different

  7. TRU Waste Sampling Program: Volume I. Waste characterization

    International Nuclear Information System (INIS)

    Clements, T.L. Jr.; Kudera, D.E.

    1985-09-01

    Volume I of the TRU Waste Sampling Program report presents the waste characterization information obtained from sampling and characterizing various aged transuranic waste retrieved from storage at the Idaho National Engineering Laboratory and the Los Alamos National Laboratory. The data contained in this report include the results of gas sampling and gas generation, radiographic examinations, waste visual examination results, and waste compliance with the Waste Isolation Pilot Plant-Waste Acceptance Criteria (WIPP-WAC). A separate report, Volume II, contains data from the gas generation studies

  8. Quantification of Protozoa and Viruses from Small Water Volumes

    Directory of Open Access Journals (Sweden)

    J. Alfredo Bonilla

    2015-06-01

    Full Text Available Large sample volumes are traditionally required for the analysis of waterborne pathogens. The need for large volumes greatly limits the number of samples that can be processed. The aims of this study were to compare extraction and detection procedures for quantifying protozoan parasites and viruses from small volumes of marine water. The intent was to evaluate a logistically simpler method of sample collection and processing that would facilitate direct pathogen measures as part of routine monitoring programs. Samples were collected simultaneously using a bilayer device with protozoa capture by size (top filter and viruses capture by charge (bottom filter. Protozoan detection technologies utilized for recovery of Cryptosporidium spp. and Giardia spp. were qPCR and the more traditional immunomagnetic separation—IFA-microscopy, while virus (poliovirus detection was based upon qPCR versus plaque assay. Filters were eluted using reagents consistent with the downstream detection technologies. Results showed higher mean recoveries using traditional detection methods over qPCR for Cryptosporidium (91% vs. 45% and poliovirus (67% vs. 55% whereas for Giardia the qPCR-based methods were characterized by higher mean recoveries (41% vs. 28%. Overall mean recoveries are considered high for all detection technologies. Results suggest that simultaneous filtration may be suitable for isolating different classes of pathogens from small marine water volumes. More research is needed to evaluate the suitability of this method for detecting pathogens at low ambient concentration levels.

  9. A low-volume cavity ring-down spectrometer for sample-limited applications

    Science.gov (United States)

    Stowasser, C.; Farinas, A. D.; Ware, J.; Wistisen, D. W.; Rella, C.; Wahl, E.; Crosson, E.; Blunier, T.

    2014-08-01

    In atmospheric and environmental sciences, optical spectrometers are used for the measurements of greenhouse gas mole fractions and the isotopic composition of water vapor or greenhouse gases. The large sample cell volumes (tens of milliliters to several liters) in commercially available spectrometers constrain the usefulness of such instruments for applications that are limited in sample size and/or need to track fast variations in the sample stream. In an effort to make spectrometers more suitable for sample-limited applications, we developed a low-volume analyzer capable of measuring mole fractions of methane and carbon monoxide based on a commercial cavity ring-down spectrometer. The instrument has a small sample cell (9.6 ml) and can selectively be operated at a sample cell pressure of 140, 45, or 20 Torr (effective internal volume of 1.8, 0.57, and 0.25 ml). We present the new sample cell design and the flow path configuration, which are optimized for small sample sizes. To quantify the spectrometer's usefulness for sample-limited applications, we determine the renewal rate of sample molecules within the low-volume spectrometer. Furthermore, we show that the performance of the low-volume spectrometer matches the performance of the standard commercial analyzers by investigating linearity, precision, and instrumental drift.

  10. [Environmental investigation of ground water contamination at Wright-Patterson Air Force Base, Ohio]. Volume 3, Appendix A, Draft standard operating procedures and elements: Sampling and Analysis Plan (SAP): Phase 1, Task 4, Field Investigation, Draft

    Energy Technology Data Exchange (ETDEWEB)

    1991-10-01

    This report presents information concerning field procedures employed during the monitoring, well construction, well purging, sampling, and well logging at the Wright-Patterson Air Force Base. Activities were conducted in an effort to evaluate ground water contamination.

  11. Advances in Radiocarbon Measurement of Water Samples

    Energy Technology Data Exchange (ETDEWEB)

    Janovics, R.; Molnar, M.; Major, I. [Institute of Nuclear Research (ATO MKI), Hungarian Academy of Sciences, H-4001 Debrecen (Hungary); Svetlik, I. [Department of Radiation Dosimetry, Nuclear Physics Institute AS CR, Prague (Czech Republic); Wacker, L. [Institute for Particle Physics, ETH Hoenggerberg, Zuerich (Switzerland)

    2013-07-15

    In this paper two very different and novel methods for the {sup 14}C measurement of water samples are presented. The first method uses direct absorption into a scintillation cocktail and a following liquid scintillation measurement. Typical sample size is 20-40 L and overall uncertainty is {+-} 2% for modern samples. It is a very cost effective and easy to use method based on a novel and simple static absorption process for the CO{sub 2} extracted from groundwater. The other very sensitive method is based on accelerator mass spectrometry (AMS) using a gas ion source. With a MICADAS type AMS system we demonstrated that you can routinely measure the {sup 14}C content of 1 mL of water sample with better than 1% precision (for a modern sample). This direct {sup 14}C AMS measurement of water takes less than 20 minutes including sample preparation. (author)

  12. Catch me if you can: Comparing ballast water sampling skids to traditional net sampling

    Science.gov (United States)

    Bradie, Johanna; Gianoli, Claudio; Linley, Robert Dallas; Schillak, Lothar; Schneider, Gerd; Stehouwer, Peter; Bailey, Sarah

    2018-03-01

    With the recent ratification of the International Convention for the Control and Management of Ships' Ballast Water and Sediments, 2004, it will soon be necessary to assess ships for compliance with ballast water discharge standards. Sampling skids that allow the efficient collection of ballast water samples in a compact space have been developed for this purpose. We ran 22 trials on board the RV Meteor from June 4-15, 2015 to evaluate the performance of three ballast water sampling devices (traditional plankton net, Triton sampling skid, SGS sampling skid) for three organism size classes: ≥ 50 μm, ≥ 10 μm to Natural sea water was run through the ballast water system and untreated samples were collected using paired sampling devices. Collected samples were analyzed in parallel by multiple analysts using several different analytic methods to quantify organism concentrations. To determine whether there were differences in the number of viable organisms collected across sampling devices, results were standardized and statistically treated to filter out other sources of variability, resulting in an outcome variable representing the mean difference in measurements that can be attributed to sampling devices. These results were tested for significance using pairwise Tukey contrasts. Differences in organism concentrations were found in 50% of comparisons between sampling skids and the plankton net for ≥ 50 μm, and ≥ 10 μm to < 50 μm size classes, with net samples containing either higher or lower densities. There were no differences for < 10 μm organisms. Future work will be required to explicitly examine the potential effects of flow velocity, sampling duration, sampled volume, and organism concentrations on sampling device performance.

  13. Water Sample Points, Navajo Nation, 2000, USACE

    Data.gov (United States)

    U.S. Environmental Protection Agency — This point shapefile presents the locations and results for water samples collected on the Navajo Nation by the US Army Corps of Engineers (USACE) for the US...

  14. Volume Ray Casting with Peak Finding and Differential Sampling

    KAUST Repository

    Knoll, A.

    2009-11-01

    Direct volume rendering and isosurfacing are ubiquitous rendering techniques in scientific visualization, commonly employed in imaging 3D data from simulation and scan sources. Conventionally, these methods have been treated as separate modalities, necessitating different sampling strategies and rendering algorithms. In reality, an isosurface is a special case of a transfer function, namely a Dirac impulse at a given isovalue. However, artifact-free rendering of discrete isosurfaces in a volume rendering framework is an elusive goal, requiring either infinite sampling or smoothing of the transfer function. While preintegration approaches solve the most obvious deficiencies in handling sharp transfer functions, artifacts can still result, limiting classification. In this paper, we introduce a method for rendering such features by explicitly solving for isovalues within the volume rendering integral. In addition, we present a sampling strategy inspired by ray differentials that automatically matches the frequency of the image plane, resulting in fewer artifacts near the eye and better overall performance. These techniques exhibit clear advantages over standard uniform ray casting with and without preintegration, and allow for high-quality interactive volume rendering with sharp C0 transfer functions. © 2009 IEEE.

  15. The WIPP Water Quality Sampling Program

    International Nuclear Information System (INIS)

    Uhland, D.; Morse, J.G.; Colton, D.

    1986-01-01

    The Waste Isolation Pilot Plant (WIPP), a Department of Energy facility, will be used for the underground disposal of wastes. The Water Quality Sampling Program (WQSP) is designed to obtain representative and reproducible water samples to depict accurate water composition data for characterization and monitoring programs in the vicinity of the WIPP. The WQSP is designed to input data into four major programs for the WIPP project: Geochemical Site Characterization, Radiological Baseline, Environmental Baseline, and Performance Assessment. The water-bearing units of interest are the Culebra and Magneta Dolomite Members of the Rustler Formation, units in the Dewey Lake Redbeds, and the Bell Canyon Formation. At least two chemically distinct types of water occur in the Culebra, one being a sodium/potassium chloride water and the other being a calcium/magnesium sulfate water. Water from the Culebra wells to the south of the WIPP site is distinctly fresher and tends to be of the calcium/magnesium sulfate type. Water in the Culebra in the north and around the WIPP site is distinctly fresher and tends to be of the sodium/potassium chloride type and is much higher in total dissolved solids. The program, which is currently 1 year old, will continue throughout the life of the facility as part of the Environmental Monitoring Program

  16. Sampling soils for 137Cs using various field-sampling volumes

    International Nuclear Information System (INIS)

    Nyhan, J.W.; Schofield, T.G.; White, G.C.; Trujillo, G.

    1981-10-01

    The sediments from a liquid effluent receiving area at the Los Alamos National Laboratory and soils from intensive study area in the fallout pathway of Trinity were sampled for 137 Cs using 25-, 500-, 2500-, and 12 500-cm 3 field sampling volumes. A highly replicated sampling program was used to determine mean concentrations and inventories of 137 Cs at each site, as well as estimates of spatial, aliquoting, and counting variance components of the radionuclide data. The sampling methods were also analyzed as a function of soil size fractions collected in each field sampling volume and of the total cost of the program for a given variation in the radionuclide survey results. Coefficients of variation (CV) of 137 Cs inventory estimates ranged from 0.063 to 0.14 for Mortandad Canyon sediments, where CV values for Trinity soils were observed from 0.38 to 0.57. Spatial variance components of 137 Cs concentration data were usually found to be larger than either the aliquoting or counting variance estimates and were inversely related to field sampling volume at the Trinity intensive site. Subsequent optimization studies of the sampling schemes demonstrated that each aliquot should be counted once, and that only 2 to 4 aliquots out of an many as 30 collected need be assayed for 137 Cs. The optimization studies showed that as sample costs increased to 45 man-hours of labor per sample, the variance of the mean 137 Cs concentration decreased dramatically, but decreased very little with additional labor

  17. Adsorption of transuranic elements from large volume sea water

    International Nuclear Information System (INIS)

    Holm, E.; Ballestra, S.

    1976-01-01

    Some years ago a sampler for concentrating radionuclides from large volumes of sea water was developed by Silker et al. of the Battelle Northwest Laboratories. They used pure A1 2 O 3 as the adsorbent. The device has been applied successfully to the determination of 238 Pu and 239 Pu in several sea water samples. Our experience on the application of an identical system for the determination of transuranics in Mediterranean sea water was not quite as satisfactory as we had hoped. The chemistry involved in leaching up to 1 kg Al 2 O 3 . with acid, followed by removal of dissolved aluminium from the transuranic fraction, is rather tedious and time-consuming for routine use. The adsorption efficiency of transuranics, checked by dual-bed adsorption did not give consistent results. However, since the principle of the device is attractive enough for handling large volume water samples, it was felt that it was worthwhile to test other types of adsorbents which are easier to handle than Al 2 O 3 . For this purpose, chitosan and manganese dioxide were chosen and series of experiments were conducted in order to examine the suitability of these materials as an adsorbent in the system

  18. Pulsed Direct Current Electrospray: Enabling Systematic Analysis of Small Volume Sample by Boosting Sample Economy.

    Science.gov (United States)

    Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong

    2015-11-17

    We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.

  19. Improvement of 137Cs analysis in small volume seawater samples using the Ogoya underground facility

    International Nuclear Information System (INIS)

    Hirose, K.; Komura, K.; Kanazawa University, Ishikawa; Aoyama, M.; Igarashi, Y.

    2008-01-01

    137 Cs in seawater is one of the most powerful tracers of water motion. Large volumes of samples have been required for determination of 137 Cs in seawater. This paper describes improvement of separation and purification processes of 137 Cs in seawater, which includes purification of 137 Cs using hexachloroplatinic acid in addition to ammonium phosphomolybdate (AMP) precipitation. As a result, we succeeded the 137 Cs determination in seawater with a smaller sample volume of 10 liter by using ultra-low background gamma-spectrometry in the Ogoya underground facility. 137 Cs detection limit was about 0.1 mBq (counting time: 10 6 s). This method is applied to determine 137 Cs in small samples of the South Pacific deep waters. (author)

  20. Determination of Sr-90 in rain water samples

    International Nuclear Information System (INIS)

    Lima, M.F.; Cunha, I.I.L.

    1988-01-01

    A work that aim is to establish radiochemical method for the determination of Sr-90 in rain water samples has been studied, as a step in an environmental monitoring program of radioactive elements. The analysis includes the preconcentration of strontium diluted in a large volume sample by precipitation of strontium as carbonate, separation of strontium from interfering elements (calcium, barium and rare earths), separation of strontium from ytrium, precipitation of purified strontium and ytrium respectively as carbonate and oxalate, and counting of Sr-90 and Y-90 activities in a low background anticoincidence beta counter. (author) [pt

  1. Portable field water sample filtration unit

    International Nuclear Information System (INIS)

    Hebert, A.J.; Young, G.G.

    1977-01-01

    A lightweight back-packable field-tested filtration unit is described. The unit is easily cleaned without cross contamination at the part-per-billion level and allows rapid filtration of boiling hot and sometimes muddy water. The filtration results in samples that are free of bacteria and particulates and which resist algae growth even after storage for months. 3 figures

  2. Influence of volume of sample processed on detection of Chlamydia trachomatis in urogenital samples by PCR

    NARCIS (Netherlands)

    Goessens, W H; Kluytmans, J A; den Toom, N; van Rijsoort-Vos, T H; Niesters, B G; Stolz, E; Verbrugh, H A; Quint, W G

    In the present study, it was demonstrated that the sensitivity of the PCR for the detection of Chlamydia trachomatis is influenced by the volume of the clinical sample which is processed in the PCR. An adequate sensitivity for PCR was established by processing at least 4%, i.e., 80 microliters, of

  3. New experimental procedure for measuring volume magnetostriction on powder samples

    International Nuclear Information System (INIS)

    Rivero, G.; Multigner, M.; Valdes, J.; Crespo, P.; Martinez, A.; Hernando, A.

    2005-01-01

    Conventional techniques used for volume magnetostriction measurements, as strain gauge or cantilever method, are very useful for ribbons or thin films but cannot be applied when the samples are in powder form. To overcome this problem a new experimental procedure has been developed. In this work, the experimental set-up is described, together with the results obtained in amorphous FeCuZr powders, which exhibit a strong dependence of the magnetization on the strength of the applied magnetic field. The magnetostriction measurements presented in this work point out that this dependence is related to a magnetovolume effect

  4. Water sampling device for detecting fuel failure

    International Nuclear Information System (INIS)

    Masubuchi, Yukio.

    1997-01-01

    A notched portion is formed at the lower end of an outer cap, and an extensible air bag is disposed being in contact with the inner side of the notched portion. A compressed air is sent into the outer gap through an air supply pipe to urge coolants thereby lowering the water level. A portion of the compressed air gets out of the outer gap from the notched portion, and if air bubbles are observed on the surface of coolants in a pressure vessel of a reactor, the outer cap is confirmed to be attached to the upper lattice plate. Compressed air is supplied to the air bag to close the notched portion. Then, coolants are sucked from a water level confirmation pipe. The level of coolants is further lowered, and the compressed air is sucked from the water level confirmation pipe instead of the coolants. Then, the level of the coolants at the inner side of the inner cap is confirmed to be made lower than the upper end of the channel box of a reactor fuel assembly. Then, coolants in the channel box are sampled, as a specimen water, through a water sampling pipe. (I.N.)

  5. An evaluation of soil sampling for 137Cs using various field-sampling volumes.

    Science.gov (United States)

    Nyhan, J W; White, G C; Schofield, T G; Trujillo, G

    1983-05-01

    The sediments from a liquid effluent receiving area at the Los Alamos National Laboratory and soils from an intensive study area in the fallout pathway of Trinity were sampled for 137Cs using 25-, 500-, 2500- and 12,500-cm3 field sampling volumes. A highly replicated sampling program was used to determine mean concentrations and inventories of 137Cs at each site, as well as estimates of spatial, aliquoting, and counting variance components of the radionuclide data. The sampling methods were also analyzed as a function of soil size fractions collected in each field sampling volume and of the total cost of the program for a given variation in the radionuclide survey results. Coefficients of variation (CV) of 137Cs inventory estimates ranged from 0.063 to 0.14 for Mortandad Canyon sediments, whereas CV values for Trinity soils were observed from 0.38 to 0.57. Spatial variance components of 137Cs concentration data were usually found to be larger than either the aliquoting or counting variance estimates and were inversely related to field sampling volume at the Trinity intensive site. Subsequent optimization studies of the sampling schemes demonstrated that each aliquot should be counted once, and that only 2-4 aliquots out of as many as 30 collected need be assayed for 137Cs. The optimization studies showed that as sample costs increased to 45 man-hours of labor per sample, the variance of the mean 137Cs concentration decreased dramatically, but decreased very little with additional labor.

  6. PIXE analysis applied to characterized water samples

    International Nuclear Information System (INIS)

    Santos, Maristela S.; Carneiro, Luana Gomes; Medeiros, Geiza; Sampaio, Camilla; Martorell, Ana Beatriz Targino; Gouvea, Stella; Cunha, Kenya Moore Dias da

    2011-01-01

    Araxa, in Brazil, is a naturally high background area located in the State of Minas Gerais with a population of about 93 672 people. Araxa is historical city famous for its mineral water sources and mud from Termas de Araxa spa, which have been used for therapeutic, and recreation purposes. Other important aspect of economy of the city are mining and metallurgic industries. In the Araxa area is located the largest deposit of pyrochlore, a niobium mineral, and also a deposit of apatite, a phosphate mineral both containing Th and U associated to crystal lattice. The minerals are obtained from open pit mines, the minerals are processed in industrial also located in city of Araxa, these plants process the pyrochlore and apatite to obtain the Fe-Nb alloy and the concentrate of phosphate, respectively. Studies were developed in this area to assessment the occupational risk of the workers due to exposure to dust particles during the routine working, however very few studies evaluated the water contamination outside the mines in order to determine the metal (stables elements) concentrations in water and also the concentrations of the radionuclides in water. This paper presents the previous results of a study to identify and determine the concentrations of metals (stables elements) and radionuclides in river around the city. The water from these rivers is used as drinking water and irrigation water. The water samples were collected in different rivers around the Araxa city and the samples were analyzed using PIXE technique. A proton beam of 2 MeV obtained from the van de Graaff electrostatic accelerator was used to induce the characteristic X-rays. S, K, Ca, Cr, Mn, Fe, Ni, Zn, Ba, Pb and U were identified in the mass spectrum of the samples. The elemental mass concentrations were compared using a non-parametric statistical test. The results of the statistical test showed that the elemental mass concentrations did not present the same distribution. These results indicated

  7. Determination of 40K in water samples

    International Nuclear Information System (INIS)

    Delgado, C. E.; Miranda C, L.; Cuevas J, A. K.; Vega C, H. R.

    2014-10-01

    The natural water used for human consumption comes from different sources, which may contain suspended solids in varying proportions. In groundwater, the source of suspended solids is related to the dissolution of mineral strata by the waters and leaching of rocks. Also, the radioactivity could concentrate on the bodies of slow-moving water that eventually could present a risk to ecosystems, as well as for the consumer. The water usually contains several natural radionuclides as: tritium, radon, radio, uranium isotopes, etc. The objective of this study was to evaluate the concentration of 40 K in water from different areas of Zacatecas state (Mexico). Four water samples were taken in triplicate from different areas; the 40 K concentration was measured with a spectrum metric system of gamma radiation with NaI (Tl) scintillation detector of 7.62 cm. In the measuring process a standard was prepared using water and KCl analytic grade where the 40 K concentration is 6.25 mol/Lt adding 250 mg/ml of potassium. Also the system was calibrated in energy using 3 point sources of 137 Cs, diameter 22 Na and 7.62 cm of height, using containers Marinelli and 60 Co. In the obtained spectra was observed that the photon of 1.432 MeV that emits the 40 K when decaying is the most important. The highest concentration was of 123 ± 5.2 Bq/lt and the lowest was of 9 ± 0.4 Bq/lt. Under the standards of drinking water, an amount of 40 K deposits an effective dose which contributes to annual dose received by people. (Author)

  8. Investigative studies on water contamination in Bangladesh. Primary treatment of water samples at the sampling site

    International Nuclear Information System (INIS)

    Sera, K.; Islam, Md. Shafiqul; Takatsuji, T.; Nakamura, T.; Goto, S.; Takahashi, C.; Saitoh, Y.

    2010-01-01

    Arsenic concentration in 13 well waters, 9 pond waters, 10 agricultural waters and a coconut juice taken in Comilla district, Bangladesh, where the problem of arsenic pollution is the most severe, was investigated. High-level arsenic is detected even in the well water which has been kept drinking by the people. Relatively high arsenic concentration was detected for some pond and farm waters even though the sampling was performed just after the rainy season and the waters were expected to be highly diluted. Clear relationship was observed in elemental compositions between the pond water and the coconut juice collected at the edge of the water. These results are expected to become the basic information for evaluating the risk of individual food such as cultured fishes, shrimps and farm products, and for controlling total intakes of arsenic. In order to solve the problem of transportation of water samples internationally, a simple method of target preparation performed at the sampling site was established and its validity was confirmed. All targets were prepared at the sampling sites in this study on the basis of this method. (author)

  9. Automated force volume image processing for biological samples.

    Directory of Open Access Journals (Sweden)

    Pavel Polyakov

    2011-04-01

    Full Text Available Atomic force microscopy (AFM has now become a powerful technique for investigating on a molecular level, surface forces, nanomechanical properties of deformable particles, biomolecular interactions, kinetics, and dynamic processes. This paper specifically focuses on the analysis of AFM force curves collected on biological systems, in particular, bacteria. The goal is to provide fully automated tools to achieve theoretical interpretation of force curves on the basis of adequate, available physical models. In this respect, we propose two algorithms, one for the processing of approach force curves and another for the quantitative analysis of retraction force curves. In the former, electrostatic interactions prior to contact between AFM probe and bacterium are accounted for and mechanical interactions operating after contact are described in terms of Hertz-Hooke formalism. Retraction force curves are analyzed on the basis of the Freely Jointed Chain model. For both algorithms, the quantitative reconstruction of force curves is based on the robust detection of critical points (jumps, changes of slope or changes of curvature which mark the transitions between the various relevant interactions taking place between the AFM tip and the studied sample during approach and retraction. Once the key regions of separation distance and indentation are detected, the physical parameters describing the relevant interactions operating in these regions are extracted making use of regression procedure for fitting experiments to theory. The flexibility, accuracy and strength of the algorithms are illustrated with the processing of two force-volume images, which collect a large set of approach and retraction curves measured on a single biological surface. For each force-volume image, several maps are generated, representing the spatial distribution of the searched physical parameters as estimated for each pixel of the force-volume image.

  10. Water evaporation: a transition path sampling study.

    Science.gov (United States)

    Varilly, Patrick; Chandler, David

    2013-02-07

    We use transition path sampling to study evaporation in the SPC/E model of liquid water. On the basis of thousands of evaporation trajectories, we characterize the members of the transition state ensemble (TSE), which exhibit a liquid-vapor interface with predominantly negative mean curvature at the site of evaporation. We also find that after evaporation is complete, the distributions of translational and angular momenta of the evaporated water are Maxwellian with a temperature equal to that of the liquid. To characterize the evaporation trajectories in their entirety, we find that it suffices to project them onto just two coordinates: the distance of the evaporating molecule to the instantaneous liquid-vapor interface and the velocity of the water along the average interface normal. In this projected space, we find that the TSE is well-captured by a simple model of ballistic escape from a deep potential well, with no additional barrier to evaporation beyond the cohesive strength of the liquid. Equivalently, they are consistent with a near-unity probability for a water molecule impinging upon a liquid droplet to condense. These results agree with previous simulations and with some, but not all, recent experiments.

  11. Sampling-based motion planning with reachable volumes: Theoretical foundations

    KAUST Repository

    McMahon, Troy

    2014-05-01

    © 2014 IEEE. We introduce a new concept, reachable volumes, that denotes the set of points that the end effector of a chain or linkage can reach. We show that the reachable volume of a chain is equivalent to the Minkowski sum of the reachable volumes of its links, and give an efficient method for computing reachable volumes. We present a method for generating configurations using reachable volumes that is applicable to various types of robots including open and closed chain robots, tree-like robots, and complex robots including both loops and branches. We also describe how to apply constraints (both on end effectors and internal joints) using reachable volumes. Unlike previous methods, reachable volumes work for spherical and prismatic joints as well as planar joints. Visualizations of reachable volumes can allow an operator to see what positions the robot can reach and can guide robot design. We present visualizations of reachable volumes for representative robots including closed chains and graspers as well as for examples with joint and end effector constraints.

  12. Sampling-based motion planning with reachable volumes: Theoretical foundations

    KAUST Repository

    McMahon, Troy; Thomas, Shawna; Amato, Nancy M.

    2014-01-01

    © 2014 IEEE. We introduce a new concept, reachable volumes, that denotes the set of points that the end effector of a chain or linkage can reach. We show that the reachable volume of a chain is equivalent to the Minkowski sum of the reachable volumes of its links, and give an efficient method for computing reachable volumes. We present a method for generating configurations using reachable volumes that is applicable to various types of robots including open and closed chain robots, tree-like robots, and complex robots including both loops and branches. We also describe how to apply constraints (both on end effectors and internal joints) using reachable volumes. Unlike previous methods, reachable volumes work for spherical and prismatic joints as well as planar joints. Visualizations of reachable volumes can allow an operator to see what positions the robot can reach and can guide robot design. We present visualizations of reachable volumes for representative robots including closed chains and graspers as well as for examples with joint and end effector constraints.

  13. Enrichment and determination of small amounts of 90Sr/90Y in water samples

    International Nuclear Information System (INIS)

    Mundschenk, H.

    1979-01-01

    Small amounts of 90 Sr/ 90 Y can be concentrated from large volumes of surface water (100 l) by precipitation of the phosphates, using bentonite as adsorber matrix. In the case of samples containing no or nearly no suspended matter (tap water, ground water, sea water), the daughter 90 Y can be extracted directly by using filter beds impregnated with HDEHP. The applicability of both techniques is demonstrated under realistic conditions. (orig.) 891 HP/orig. 892 MKO [de

  14. Efficient low static-volume water heater

    Science.gov (United States)

    Brown, R. L.

    1976-01-01

    Calrod heating element is surrounded by matrix of fused sintered copper or brass balls, and assembly is then installed in piping of water system. As water flows through matrix, sintered balls cause turbulent flow and heating. Applications include laundromats, laboratories, and photographic labs.

  15. Assembly, operation and disassembly manual for the Battelle Large Volume Water Sampler (BLVWS)

    International Nuclear Information System (INIS)

    Thomas, V.W.; Campbell, R.M.

    1984-12-01

    Assembly, operation and disassembly of the Battelle Large Volume Water Sampler (BLVWS) are described in detail. Step by step instructions of assembly, general operation and disassembly are provided to allow an operator completely unfamiliar with the sampler to successfully apply the BLVWS to his research sampling needs. The sampler permits concentration of both particulate and dissolved radionuclides from large volumes of ocean and fresh water. The water sample passes through a filtration section for particle removal then through sorption or ion exchange beds where species of interest are removed. The sampler components which contact the water being sampled are constructed of polyvinylchloride (PVC). The sampler has been successfully applied to many sampling needs over the past fifteen years. 9 references, 8 figures

  16. Using Mobile Device Samples to Estimate Traffic Volumes

    Science.gov (United States)

    2017-12-01

    In this project, TTI worked with StreetLight Data to evaluate a beta version of its traffic volume estimates derived from global positioning system (GPS)-based mobile devices. TTI evaluated the accuracy of average annual daily traffic (AADT) volume :...

  17. Modeling Approach for Estimating Co-Produced Water Volumes and Saltwater Disposal Volumes in Oklahoma

    Science.gov (United States)

    Murray, K. E.

    2016-12-01

    Management of produced fluids has become an important issue in Oklahoma because large volumes of saltwater are co-produced with oil and gas, and disposed into saltwater disposal wells at high rates. Petroleum production increased from 2009-2015, especially in central and north-central Oklahoma where the Mississippian and Hunton zones were redeveloped using horizontal wells and dewatering techniques that have led to a disproportional increase in produced water volumes. Improved management of co-produced water, including desalination for beneficial reuse and decreased saltwater disposal volumes, is only possible if spatial and temporal trends can be defined and related to the producing zones. It is challenging to quantify the volumes of co-produced water by region or production zone because co-produced water volumes are generally not reported. Therefore, the goal of this research is to estimate co-produced water volumes for 2008-present with an approach that can be replicated as petroleum production shifts to other regions. Oil and gas production rates from subsurface zones were multiplied by ratios of H2O:oil and H2O:gas for the respective zones. Initial H2O:oil and H2O:gas ratios were adjusted/calibrated, by zone, to maximize correlation of county-scale produced H2O estimates versus saltwater disposal volumes from 2013-2015. These calibrated ratios were then used to compute saltwater disposal volumes from 2008-2012 because of apparent data gaps in reported saltwater disposal volumes during that timeframe. This research can be used to identify regions that have the greatest need for produced water treatment systems. The next step in management of produced fluids is to explore optimal energy-efficient strategies that reduce deleterious effects.

  18. Micellar electrokinetic chromatographic determination of triazine herbicides in water samples.

    Science.gov (United States)

    Li, Zhi; Zhang, Shuaihua; Yin, Xiaofang; Wang, Chun; Wang, Zhi

    2014-09-01

    Dispersive liquid-liquid microextraction combined with online sweeping preconcentration in micellar electrokinetic chromatography was developed for the simultaneous determination of five triazine herbicides (atrazine, simazine, propazine, prometon and simetryn) in water samples. Several experimental parameters affecting the extraction efficiencies such as the type and volume of both the extraction and dispersive solvents, the addition of salt to sample solution, the extraction time and the pH of the sample solution were investigated. Under optimum conditions, the linearity of the method was good in the range from 0.33 to 20 ng mL(-1) for simazine, propazine, atrazine and simetryn, and from 0.17 to 20 ng mL(-1) for prometon, respectively. The sensitivity enrichment factors were in the range from 1750 to 2100, depending on the compound. The limit of detection (S/N = 3) ranged from 0.05 to 0.10 ng mL(-1). The developed method was successfully applied to the analysis of the five triazines in river, ground and well waters. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Technical procedures for water resources: Volume 4, Deaf Smith County site, Texas: Environmental Field Program: Final draft

    International Nuclear Information System (INIS)

    1987-08-01

    This volume contains Technical Procedures pursuant to the water Resources Site Study Plan: including Collection, Preservation, and Shipment of Ground-Water Samples; Inventory Current Water Use and Estimating Projected Water Use; Estimation of Precipitation Depth, Duration, Frequence; Estimation of Probable Maximum Precipitation; Calculation of Floodplains

  20. UMTRA project water sampling and analysis plan, Maybell, Colorado

    International Nuclear Information System (INIS)

    1994-06-01

    This water sampling and analysis plan (WSAP) describes planned water sampling activities and provides the regulatory and technical basis for ground water sampling in 1994 at the US Department of Energy's (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site in Maybell, Colorado. The WSAP identifies and justifies sampling locations, analytical parameters, and sampling frequencies at the site. The ground water data will be used for site characterization and risk assessment. The regulatory basis for the ground water and surface water monitoring activities is derived from the EPA regulations in 40 CFR Part 192 (1993) and the proposed EPA standards of 1987 (52 FR 36000). Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), the Technical Approach Document (TAD) (DOE, 1989), and the most effective technical approach for the site. This WSAP also includes a summary and the results of water sampling activities from 1989 through 1992 (no sampling was performed in 1993)

  1. Water Resources Data. Ohio - Water Year 1992. Volume 1. Ohio River Basin excluding project data

    Energy Technology Data Exchange (ETDEWEB)

    H.L. Shindel; J.H. Klingler; J.P. Mangus; L.E. Trimble

    1993-03-01

    Water-resources data for the 1992 water year for Ohio consist of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground-water wells. This report, in two volumes, contains records for water discharge at 121 gaging stations, 336 wells, and 72 partial-record sites; and water levels at 312 observation wells. Also included are data from miscellaneous sites. Additional water data were collected at various sites not involved in the systematic data-collection program and are published as miscellaneous measurements and analyses. These data represent that part of the National Water Data System collected by the US Geological Survey and cooperating State and Federal agencies in Ohio. Volume 1 covers the central and southern parts of Ohio, emphasizing the Ohio River Basin. (See Order Number DE95010451 for Volume 2 covering the northern part of Ohio.)

  2. Produced water volumes and management practices in the United States.

    Energy Technology Data Exchange (ETDEWEB)

    Clark, C. E.; Veil, J. A. (Environmental Science Division)

    2009-09-01

    Produced water volume generation and management in the United States are not well characterized at a national level. The U.S. Department of Energy (DOE) asked Argonne National Laboratory to compile data on produced water associated with oil and gas production to better understand the production volumes and management of this water. The purpose of this report is to improve understanding of produced water by providing detailed information on the volume of produced water generated in the United States and the ways in which produced water is disposed or reused. As the demand for fresh water resources increases, with no concomitant increase in surface or ground water supplies, alternate water sources, like produced water, may play an important role. Produced water is water from underground formations that is brought to the surface during oil or gas production. Because the water has been in contact with hydrocarbon-bearing formations, it contains some of the chemical characteristics of the formations and the hydrocarbons. It may include water from the reservoir, water previously injected into the formation, and any chemicals added during the production processes. The physical and chemical properties of produced water vary considerably depending on the geographic location of the field, the geologic formation, and the type of hydrocarbon product being produced. Produced water properties and volume also vary throughout the lifetime of a reservoir. Produced water is the largest volume by-product or waste stream associated with oil and gas exploration and production. Previous national produced water volume estimates are in the range of 15 to 20 billion barrels (bbl; 1 bbl = 42 U.S. gallons) generated each year in the United States (API 1988, 2000; Veil et al. 2004). However, the details on generation and management of produced water are not well understood on a national scale. Argonne National Laboratory developed detailed national-level information on the volume of produced

  3. UMTRA water sampling and analysis plan, Green River, Utah

    International Nuclear Information System (INIS)

    Papusch, R.

    1993-12-01

    The purpose of this water sampling and analysis plan (WSAP) is to provide a basis for groundwater and surface water sampling at the Green River Uranium Mill Tailing Remedial Action (UMTRA) Project site. This WSAP identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the monitoring locations

  4. Multielement neutron activation analysis of underground water samples

    International Nuclear Information System (INIS)

    Kusaka, Yuzuru; Tsuji, Haruo; Fujimoto, Yuzo; Ishida, Keiko; Mamuro, Tetsuo.

    1980-01-01

    An instrumental neutron activation analysis by gamma-ray spectrometry with high resolution and large volume Ge (Li) detectors followed by data processing with an electronic computer was applied to the multielemental analysis to elucidate the chemical qualities of the underground water which has been widely used in the sake brewing industries in Mikage, Uozaki and Nishinomiya districts, called as miyamizu. The evaporated residues of the water samples were subjected to the neutron irradiations in reactor for 1 min at a thermal flux of 1.5 x 10 12 n.cm -2 .sec -1 and for 30 hrs at a thermal flux of 9.3 x 10 11 n.cm -2 .sec -1 or for 5 hrs at a thermal flux of 3.9 x 10 12 n.cm -2 .sec -1 . Thus, 11 elements in the former short irradiation and 38 elements in the latter two kinds of long irradiation can be analyzed. Conventional chemical analysis including atomic absorption method and others are also applied on the same samples, and putting the all results together, some considerations concerning the geochemical meaning of the analytical values are made. (author)

  5. Polymeric ionic liquid-based portable tip microextraction device for on-site sample preparation of water samples.

    Science.gov (United States)

    Chen, Lei; Pei, Junxian; Huang, Xiaojia; Lu, Min

    2018-06-05

    On-site sample preparation is highly desired because it avoids the transportation of large-volume samples and ensures the accuracy of the analytical results. In this work, a portable prototype of tip microextraction device (TMD) was designed and developed for on-site sample pretreatment. The assembly procedure of TMD is quite simple. Firstly, polymeric ionic liquid (PIL)-based adsorbent was in-situ prepared in a pipette tip. After that, the tip was connected with a syringe which was driven by a bidirectional motor. The flow rates in adsorption and desorption steps were controlled accurately by the motor. To evaluate the practicability of the developed device, the TMD was used to on-site sample preparation of waters and combined with high-performance liquid chromatography with diode array detection to measure trace estrogens in water samples. Under the most favorable conditions, the limits of detection (LODs, S/N = 3) for the target analytes were in the range of 4.9-22 ng/L, with good coefficients of determination. Confirmatory study well evidences that the extraction performance of TMD is comparable to that of the traditional laboratory solid-phase extraction process, but the proposed TMD is more simple and convenient. At the same time, the TMD avoids complicated sampling and transferring steps of large-volume water samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Legacy sample disposition project. Volume 2: Final report

    International Nuclear Information System (INIS)

    Gurley, R.N.; Shifty, K.L.

    1998-02-01

    This report describes the legacy sample disposition project at the Idaho Engineering and Environmental Laboratory (INEEL), which assessed Site-wide facilities/areas to locate legacy samples and owner organizations and then characterized and dispositioned these samples. This project resulted from an Idaho Department of Environmental Quality inspection of selected areas of the INEEL in January 1996, which identified some samples at the Test Reactor Area and Idaho Chemical Processing Plant that had not been characterized and dispositioned according to Resource Conservation and Recovery Act (RCRA) requirements. The objective of the project was to manage legacy samples in accordance with all applicable environmental and safety requirements. A systems engineering approach was used throughout the project, which included collecting the legacy sample information and developing a system for amending and retrieving the information. All legacy samples were dispositioned by the end of 1997. Closure of the legacy sample issue was achieved through these actions

  7. Mass transfer of H2O between petroleum and water: implications for oil field water sample quality

    International Nuclear Information System (INIS)

    McCartney, R.A.; Ostvold, T.

    2005-01-01

    Water mass transfer can occur between water and petroleum during changes in pressure and temperature. This process can result in the dilution or concentration of dissolved ions in the water phase of oil field petroleum-water samples. In this study, PVT simulations were undertaken for 4 petroleum-water systems covering a range of reservoir conditions (80-185 o C; 300-1000 bar) and a range of water-petroleum mixtures (volume ratios of 1:1000-300:1000) to quantify the extent of H 2 O mass transfer as a result of pressure and temperature changes. Conditions were selected to be relevant to different types of oil field water sample (i.e. surface, downhole and core samples). The main variables determining the extent of dilution and concentration were found to be: (a) reservoir pressure and temperature, (b) pressure and temperature of separation of water and petroleum, (c) petroleum composition, and (d) petroleum:water ratio (PWR). The results showed that significant dilution and concentration of water samples could occur, particularly at high PWR. It was not possible to establish simple guidelines for identifying good and poor quality samples due to the interplay of the above variables. Sample quality is best investigated using PVT software of the type used in this study. (author)

  8. Water-vapor pressure control in a volume

    Science.gov (United States)

    Scialdone, J. J.

    1978-01-01

    The variation with time of the partial pressure of water in a volume that has openings to the outside environment and includes vapor sources was evaluated as a function of the purging flow and its vapor content. Experimental tests to estimate the diffusion of ambient humidity through openings and to validate calculated results were included. The purging flows required to produce and maintain a certain humidity in shipping containers, storage rooms, and clean rooms can be estimated with the relationship developed here. These purging flows are necessary to prevent the contamination, degradation, and other effects of water vapor on the systems inside these volumes.

  9. Macroscopic investigation of water volume effects on interfacial dynamic behaviors between clathrate hydrate and water.

    Science.gov (United States)

    Cha, Minjun; Couzis, Alexander; Lee, Jae W

    2013-05-14

    This study investigated the effects of the water volume on the interfacial dynamics between cyclopentane (CP) hydrate and water droplet in a CP/n-decane oil mixture. The adhesion force between CP hydrate and various water droplets was determined using the z-directional microbalance. Through repetition of precise measurements over several cycles from contact to detachment, we observed abnormal wetting behaviors in the capillary bridge during the retraction process when the water drop volume is larger than 100 μL. With the increase in water droplet volumes, the contact force between CP hydrate and water also increases up to 300 μL. However, there is a dramatic reduction of increasing rate in the contact forces over 300 μL of water droplet. With the addition of the surfactants of sodium dodecyl sulfate (SDS) and dodecyltrimethylammonium bromide (DTAB) to the water droplet, the contact force between CP hydrate and solution droplet exhibits a lower value and a transition volume of the contact force comes with a smaller solution volume of 200 μL. The water volume effects on the liquid wetting of the probe and the size of capillary bridges provide important insight into hydrate growth and aggregation/agglomeration in the presence of free water phase inside gas/oil pipelines.

  10. Recovery of diverse microbes in high turbidity surface water samples using dead-end ultrafiltration.

    Science.gov (United States)

    Mull, Bonnie; Hill, Vincent R

    2012-12-01

    Dead-end ultrafiltration (DEUF) has been reported to be a simple, field-deployable technique for recovering bacteria, viruses, and parasites from large-volume water samples for water quality testing and waterborne disease investigations. While DEUF has been reported for application to water samples having relatively low turbidity, little information is available regarding recovery efficiencies for this technique when applied to sampling turbid water samples such as those commonly found in lakes and rivers. This study evaluated the effectiveness of a DEUF technique for recovering MS2 bacteriophage, enterococci, Escherichia coli, Clostridium perfringens, and Cryptosporidium parvum oocysts in surface water samples having elevated turbidity. Average recovery efficiencies for each study microbe across all turbidity ranges were: MS2 (66%), C. parvum (49%), enterococci (85%), E. coli (81%), and C. perfringens (63%). The recovery efficiencies for MS2 and C. perfringens exhibited an inversely proportional relationship with turbidity, however no significant differences in recovery were observed for C. parvum, enterococci, or E. coli. Although ultrafilter clogging was observed, the DEUF method was able to process 100-L surface water samples at each turbidity level within 60 min. This study supports the use of the DEUF method for recovering a wide array of microbes in large-volume surface water samples having medium to high turbidity. Published by Elsevier B.V.

  11. Par Pond refill water quality sampling

    International Nuclear Information System (INIS)

    Koch, J.W. II; Martin, F.D.; Westbury, H.M.

    1996-08-01

    This study was designed to document anoxia and its cause in the event that the anoxia caused a fish kill. However, no fish kill was observed during this study, and dissolved oxygen and nutrient concentrations generally remained within the range expected for southeastern reservoirs. Par Pond water quality monitoring will continue during the second summer after refill as the aquatic macrophytes become reestablished and nutrients in the sediments are released to the water column

  12. Technical Note: New methodology for measuring viscosities in small volumes characteristic of environmental chamber particle samples

    Directory of Open Access Journals (Sweden)

    L. Renbaum-Wolff

    2013-01-01

    Full Text Available Herein, a method for the determination of viscosities of small sample volumes is introduced, with important implications for the viscosity determination of particle samples from environmental chambers (used to simulate atmospheric conditions. The amount of sample needed is < 1 μl, and the technique is capable of determining viscosities (η ranging between 10−3 and 103 Pascal seconds (Pa s in samples that cover a range of chemical properties and with real-time relative humidity and temperature control; hence, the technique should be well-suited for determining the viscosities, under atmospherically relevant conditions, of particles collected from environmental chambers. In this technique, supermicron particles are first deposited on an inert hydrophobic substrate. Then, insoluble beads (~1 μm in diameter are embedded in the particles. Next, a flow of gas is introduced over the particles, which generates a shear stress on the particle surfaces. The sample responds to this shear stress by generating internal circulations, which are quantified with an optical microscope by monitoring the movement of the beads. The rate of internal circulation is shown to be a function of particle viscosity but independent of the particle material for a wide range of organic and organic-water samples. A calibration curve is constructed from the experimental data that relates the rate of internal circulation to particle viscosity, and this calibration curve is successfully used to predict viscosities in multicomponent organic mixtures.

  13. Physico-chemical characteristics of water sample from Aiba Stream ...

    African Journals Online (AJOL)

    This study aimed at assessing the effectiveness of solar distillation in purification of water. The water sample collected from Aiba stream was subjected to double slope solar water distillation unit. The physico- chemical characteristics of the raw sample and the distillate were determined using standard methods. The.

  14. UMTRA project water sampling and analysis plan, Gunnison, Colorado

    International Nuclear Information System (INIS)

    1994-06-01

    This water sampling and analysis plan summarizes the results of previous water sampling activities and the plan for water sampling activities for calendar year 1994. A buffer zone monitoring plan is included as an appendix. The buffer zone monitoring plan is designed to protect the public from residual contamination that entered the ground water as a result of former milling operations. Surface remedial action at the Gunnison Uranium Mill Tailings Remedial Action Project site began in 1992; completion is expected in 1995. Ground water and surface water will be sampled semiannually in 1994 at the Gunnison processing site (GUN-01) and disposal site (GUN-08). Results of previous water sampling at the Gunnison processing site indicate that ground water in the alluvium is contaminated by the former uranium processing activities. Background ground water conditions have been established in the uppermost aquifer (Tertiary gravels) at the Gunnison disposal site. The monitor well locations provide a representative distribution of sampling points to characterize ground water quality and ground water flow conditions in the vicinity of the sites. The list of analytes has been modified with time to reflect constituents that are related to uranium processing activities and the parameters needed for geochemical evaluation. Water sampling will be conducted at least semiannually during and one year following the period of construction activities, to comply with the ground water protection strategy discussed in the remedial action plan (DOE, 1992a)

  15. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 2, Radiation Monitoring and Sampling

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The FRMAC Monitoring and Sampling Manual, Volume 2 provides standard operating procedures (SOPs) for field radiation monitoring and sample collection activities that are performed by the Monitoring group during a FRMAC response to a radiological emergency.

  16. Analysis of phthalate esters contamination in drinking water samples ...

    African Journals Online (AJOL)

    The optimum condition method was successfully applied to the analysis of phthalate esters contamination in bottled drinking water samples. The concentration of DMP, DEP and DBP in drinking water samples were below allowable levels, while the DEHP concentration in three samples was found to be greater than the ...

  17. Contamination of ground and surface waters by uranium mining and milling. Volume II. Field sampling and empirical modeling. Open file report (final) 25 Jul 79-14 Sep 81

    International Nuclear Information System (INIS)

    Markos, G.; Bush, K.J.

    1981-12-01

    Uranium mill tailings represent a potential threat to the human habitat by containing large amounts of radioactive and chemically toxic substances in high concentrations. These undesired components enter the human habitat in various pathways such as by erosion and water or air transport. The main objective of this investigation was to evaluate the actual movement and model the potential movement of contaminants by seepage of water from the tailings into the subtailings soil. This report represents various models of the movement of contaminants using both theoretical approaches and empirical evaluation of data available from other investigations. Data analysis shows that the critical area of investigating movements is the interfaces between tailings and the external environment. The chemical differences at interfaces seem to result in a sink system for contaminants. The tailings-soil-water system shows extreme complexities because of chemical and physical heterogeneity of the system preventing the use of a single comprehensive model to represent real conditions. The validity of the simplifying assumption used has been shown and increasing complexity has been built into the models. Analogs of these models can be used for evaluation of similar systems

  18. Guidelines for sampling fish in inland waters

    National Research Council Canada - National Science Library

    Backiel, Tadeusz; Welcomme, R. L

    1980-01-01

    The book is addressed mainly to Fishery Biologists but it is hoped that Fishing Gear Technologists also can acquire some basic knowledge of sampling problems and procedures which, in turn, can result...

  19. UMTRA project water sampling and analysis plan -- Shiprock, New Mexico

    International Nuclear Information System (INIS)

    1994-02-01

    Water sampling and analysis plan (WSAP) is required for each U.S. Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site to provide a basis for ground water and surface water sampling at disposal and former processing sites. This WSAP identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the monitoring stations at the Navaho Reservation in Shiprock, New Mexico, UMTRA Project site. The purposes of the water sampling at Shiprock for fiscal year (FY) 1994 are to (1) collect water quality data at new monitoring locations in order to build a defensible statistical data base, (2) monitor plume movement on the terrace and floodplain, and (3) monitor the impact of alluvial ground water discharge into the San Juan River. The third activity is important because the community of Shiprock withdraws water from the San Juan River directly across from the contaminated alluvial floodplain below the abandoned uranium mill tailings processing site

  20. Critical length sampling: a method to estimate the volume of downed coarse woody debris

    Science.gov (United States)

    G& #246; ran St& #229; hl; Jeffrey H. Gove; Michael S. Williams; Mark J. Ducey

    2010-01-01

    In this paper, critical length sampling for estimating the volume of downed coarse woody debris is presented. Using this method, the volume of downed wood in a stand can be estimated by summing the critical lengths of down logs included in a sample obtained using a relascope or wedge prism; typically, the instrument should be tilted 90° from its usual...

  1. Spectrophotometric Determination of Boron in Environmental Water Samples

    International Nuclear Information System (INIS)

    San San; Khin Win Kyi; Kwaw Naing

    2002-02-01

    The present paper deals with the study on the methods for the determination of boron in the environmental water samples. The standard methods which are useful for this determination are discussed thoroughly in this work. Among the standard methods approved by American Public Health Association, the carmine method was selected for this study. Prior to the determination of boron in the water samples, the precision and accuracy of the methods of choice were examined by using standard boron solutions. The determination of Boron was carried out by using water samples, waste water from Aquaculture Research Centre, University of Yangon, the Ayeyarwady River water near Magway Myathalon Pagoda in Magway Division, ground water from Sanchaung Township, and tap water from Universities' Research Centre, University of Yangon. Analyses of these water samples were done and statistical treatment of the results was carried out. (author)

  2. “Nanofiltration” Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples

    Science.gov (United States)

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.

    2016-01-01

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation. PMID:26876979

  3. Fluorescent determination of graphene quantum dots in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Benítez-Martínez, Sandra; Valcárcel, Miguel, E-mail: qa1meobj@uco.es

    2015-10-08

    This work presents a simple, fast and sensitive method for the preconcentration and quantification of graphene quantum dots (GQDs) in aqueous samples. GQDs are considered an object of analysis (analyte) not an analytical tool which is the most frequent situation in Analytical Nanoscience and Nanotechnology. This approach is based on the preconcentration of graphene quantum dots on an anion exchange sorbent by solid phase extraction and their subsequent elution prior fluorimetric analysis of the solution containing graphene quantum dots. Parameters of the extraction procedure such as sample volume, type of solvent, sample pH, sample flow rate and elution conditions were investigated in order to achieve extraction efficiency. The limits of detection and quantification were 7.5 μg L{sup −1} and 25 μg L{sup −1}, respectively. The precision for 200 μg L{sup −1}, expressed as %RSD, was 2.8%. Recoveries percentages between 86.9 and 103.9% were obtained for two different concentration levels. Interferences from other nanoparticles were studied and no significant changes were observed at the concentration levels tested. Consequently, the optimized procedure has great potential to be applied to the determination of graphene quantum dots at trace levels in drinking and environmental waters. - Highlights: • Development of a novel and simple method for determination of graphene quantum dots. • Preconcentration of graphene quantum dots by solid phase extraction. • Fluorescence spectroscopy allows fast measurements. • High sensitivity and great reproducibility are achieved.

  4. chemical and microbiological assessment of surface water samples

    African Journals Online (AJOL)

    PROF EKWUEME

    were investigated in this study: Nine samples from different surface water bodies, two samples from two effluent sources ... Ezeagu, Udi, Nkanu, Oji River and some parts of Awgu and Aninri ..... Study of Stream Output from Small Catchments.

  5. Preconcentration NAA for simultaneous multielemental determination in water sample

    International Nuclear Information System (INIS)

    Chatt, A.

    1999-01-01

    Full text: Environment concerns with water, air, land and their interrelationship viz., human beings, fauna and flora. One of the important environmental compartments is water. Elements present in water might face a whole lot of physico-chemical conditions. This poses challenges to measure their total concentrations as well as different species. Preconcentration of the elements present in water samples is a necessary requisites in water analysis. For multi elements concentration measurements, Neutron Activation Analysis (NAA) is one of the preferred analytical techniques due to its sensitivity and selectivity. In this talk preconcentration NAA for multielemental determination in water sample determination will be discussed

  6. Water resources data, Iowa, water year 2001, Volume 2. surface water--Missouri River basin, and ground water

    Science.gov (United States)

    Nalley, G.M.; Gorman, J.G.; Goodrich, R.D.; Miller, V.E.; Turco, M.J.; Linhart, S.M.

    2002-01-01

    The Water Resources Division of the U.S. Geological Survey, in cooperation with State, county, municipal, and other Federal agencies, obtains a large amount of data pertaining to the water resources of Iowa each water year. These data, accumulated during many water years, constitute a valuable data base for developing an improved understanding of the water resources of the State. To make this data readily available to interested parties outside of the Geological Survey, the data is published annually in this report series entitled “Water Resources Data - Iowa” as part of the National Water Data System. Water resources data for water year 2001 for Iowa consists of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground water. This report, in two volumes, contains stage or discharge records for 132 gaging stations; stage records for 9 lakes and reservoirs; water-quality records for 4 gaging stations; sediment records for 13 gaging stations; and water levels for 163 ground-water observation wells. Also included are peak-flow data for 92 crest-stage partial-record stations, water-quality data from 86 municipal wells, and precipitation data collected at 6 gaging stations and 2 precipitation sites. Additional water data were collected at various sites not included in the systematic data-collection program, and are published here as miscellaneous measurements and analyses. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating local, State, and Federal agencies in Iowa.Records of discharge or stage of streams, and contents or stage of lakes and reservoirs were first published in a series of U.S. Geological Survey water-supply papers entitled “Surface Water Supply of the United States.” Through September 30, 1960, these water-supply papers were published in an annual series; during 1961-65 and 1966-70, they

  7. Liquid Water from First Principles: Validation of Different Sampling Approaches

    Energy Technology Data Exchange (ETDEWEB)

    Mundy, C J; Kuo, W; Siepmann, J; McGrath, M J; Vondevondele, J; Sprik, M; Hutter, J; Parrinello, M; Mohamed, F; Krack, M; Chen, B; Klein, M

    2004-05-20

    A series of first principles molecular dynamics and Monte Carlo simulations were carried out for liquid water to assess the validity and reproducibility of different sampling approaches. These simulations include Car-Parrinello molecular dynamics simulations using the program CPMD with different values of the fictitious electron mass in the microcanonical and canonical ensembles, Born-Oppenheimer molecular dynamics using the programs CPMD and CP2K in the microcanonical ensemble, and Metropolis Monte Carlo using CP2K in the canonical ensemble. With the exception of one simulation for 128 water molecules, all other simulations were carried out for systems consisting of 64 molecules. It is found that the structural and thermodynamic properties of these simulations are in excellent agreement with each other as long as adiabatic sampling is maintained in the Car-Parrinello molecular dynamics simulations either by choosing a sufficiently small fictitious mass in the microcanonical ensemble or by Nos{acute e}-Hoover thermostats in the canonical ensemble. Using the Becke-Lee-Yang-Parr exchange and correlation energy functionals and norm-conserving Troullier-Martins or Goedecker-Teter-Hutter pseudopotentials, simulations at a fixed density of 1.0 g/cm{sup 3} and a temperature close to 315 K yield a height of the first peak in the oxygen-oxygen radial distribution function of about 3.0, a classical constant-volume heat capacity of about 70 J K{sup -1} mol{sup -1}, and a self-diffusion constant of about 0.1 Angstroms{sup 2}/ps.

  8. Critical point relascope sampling for unbiased volume estimation of downed coarse woody debris

    Science.gov (United States)

    Jeffrey H. Gove; Michael S. Williams; Mark J. Ducey; Mark J. Ducey

    2005-01-01

    Critical point relascope sampling is developed and shown to be design-unbiased for the estimation of log volume when used with point relascope sampling for downed coarse woody debris. The method is closely related to critical height sampling for standing trees when trees are first sampled with a wedge prism. Three alternative protocols for determining the critical...

  9. Measurement of radioactivity in water samples

    International Nuclear Information System (INIS)

    Richards, L.

    1990-01-01

    Public concern about the levels of radioactivity release to the environment whether authorised discharges or resulting from nuclear accident, has increased in recent years. Consequently there is increasing pressure for reliable data on the distribution of radioactivity and the extent of its intrusion into food chains and water supplies. As a result a number of laboratories not experienced in radioactivity measurements have acquired nucleonic counting equipment. These notes explore the underlying basics and indicate sources of essential data and information which are required for a better understanding of radioactivity measurements. Particular attention is directed to the screening tests which are usually designated ''gross'' alpha and ''gross'' beta activity measurement. (author)

  10. UMTRA project water sampling and analysis plan, Naturita, Colorado

    International Nuclear Information System (INIS)

    1994-04-01

    Surface remedial action is scheduled to begin at the Naturita UMTRA Project processing site in the spring of 1994. No water sampling was performed during 1993 at either the Naturita processing site (NAT-01) or the Dry Flats disposal site (NAT-12). Results of previous water sampling at the Naturita processing site indicate that ground water in the alluvium is contaminated as a result of uranium processing activities. Baseline ground water conditions have been established in the uppermost aquifer at the Dry Flats disposal site. Water sampling activities scheduled for April 1994 include preconstruction sampling of selected monitor wells at the processing site, surface water sampling of the San Miguel River, sampling of several springs/seeps in the vicinity of the disposal site, and sampling of two monitor wells in Coke Oven Valley. The monitor well locations provide sampling points to characterize ground water quality and flow conditions in the vicinity of the sites. The list of analytes has been updated to reflect constituents related to uranium processing activities and the parameters needed for geochemical evaluation. Water sampling will be conducted annually at minimum during the period of construction activities

  11. Characterization samples of Tigris river water treated with nano colloidal silver (physically, chemically, microbiologically)

    International Nuclear Information System (INIS)

    Dumboos, H. I.; Beden, S. J.; Zouari, K.; Chkir, N.; Ahmed, H. A.

    2012-12-01

    Many researches of using nano silver in purification of drinking water from bacteria and its effect on stan dared properties as drinking water were established. Two stages accomplished in these projects. First stage include preparation of colloidal silver with characterization process and prepare water samples through sedimentation, filtration process, PH and turbidity measure then treated with colloidal silver in volume ratio (0.1-Λ) ml/100ml. The second stage represent select the better results from stage one and take samples to determine the standard characterization values with chemical, physical and microbiological taste. Results will be compared with Iraq standard certification. (Author)

  12. Dilatometric measurement of the partial molar volume of water sorbed to durum wheat flour.

    Science.gov (United States)

    Hasegawa, Ayako; Ogawa, Takenobu; Adachi, Shuji

    2013-01-01

    Moisture sorption isotherms were measured at 25 °C for untreated, dry-heated and pre-gelatinized durum wheat flour samples. The isotherms could be expressed by the Guggenheim-Anderson-de Boer equation. The amount of water sorbed to the untreated flour was highest for low water activity, with water sorbed to the pre-gelatinized and dry-heated flour samples following. The dry-heated and pregelatinized flour samples exhibited the same dependence of the moisture content on the partial molar volume of water at 25 °C as the untreated flour. The partial molar volume of water was ca. 9 cm(3)/mol at a moisture content of 0.03 kg-H2O/kg-d.m. The volume increased with increasing moisture content, and reached a constant value of ca. 17.5 cm(3)/mol at a moisture content of 0.2 kg-H2O/kg-d.m. or higher.

  13. PCR detection of Burkholderia multivorans in water and soil samples.

    Science.gov (United States)

    Peeters, Charlotte; Daenekindt, Stijn; Vandamme, Peter

    2016-08-12

    Although semi-selective growth media have been developed for the isolation of Burkholderia cepacia complex bacteria from the environment, thus far Burkholderia multivorans has rarely been isolated from such samples. Because environmental B. multivorans isolates mainly originate from water samples, we hypothesized that water rather than soil is its most likely environmental niche. The aim of the present study was to assess the occurrence of B. multivorans in water samples from Flanders (Belgium) using a fast, culture-independent PCR assay. A nested PCR approach was used to achieve high sensitivity, and specificity was confirmed by sequencing the resulting amplicons. B. multivorans was detected in 11 % of the water samples (n = 112) and 92 % of the soil samples (n = 25) tested. The percentage of false positives was higher for water samples compared to soil samples, showing that the presently available B. multivorans recA primers lack specificity when applied to the analysis of water samples. The results of the present study demonstrate that B. multivorans DNA is commonly present in soil samples and to a lesser extent in water samples in Flanders (Belgium).

  14. Microbial Condition of Water Samples from Foreign Fuel Storage Facilities

    International Nuclear Information System (INIS)

    Berry, C.J.

    1998-01-01

    In order to assess the microbial condition of foreign spent nuclear fuel storage facilities and their possible impact on SRS storage basins, twenty-three water samples were analyzed from 12 different countries. Fifteen of the water samples were analyzed and described in an earlier report (WSRC-TR-97-00365 [1]). This report describes nine additional samples received from October 1997 through March 1998. The samples include three from Australia, two from Denmark and Germany and one sample from Italy and Greece. Each water sample was analyzed for microbial content and activity as determined by total bacteria, viable aerobic bacteria, viable anaerobic bacteria, viable sulfate-reducing bacteria, viable acid-producing bacteria and enzyme diversity. The results for each water sample were then compared to all other foreign samples analyzed to date and monthly samples pulled from the receiving basin for off-site fuel (RBOF), at SRS. Of the nine samples analyzed, four samples from Italy, Germany and Greece had considerably higher microbiological activity than that historically found in the RBOF. This microbial activity included high levels of enzyme diversity and the presence of viable organisms that have been associated with microbial influenced corrosion in other environments. The three samples from Australia had microbial activities similar to that in the RBOF while the two samples from Denmark had lower levels of microbial activity. These results suggest that a significant number of the foreign storage facilities have water quality standards that allow microbial proliferation and survival

  15. Water Resources Data Ohio: Water year 1994. Volume 1, Ohio River Basin excluding Project Data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Water Resources Division of the US Geological Survey (USGS) in cooperation with State agencies, obtains a large amount of data each water year (a water year is the 12-month period from October 1 through September 30 and is identified by the calendar year in which it ends) pertaining to the water resources of Ohio. These data, accumulated during many years, constitute a valuable data base for developing an improved understanding of the water resources of the State. To make these data readily available to interested parties outside the USGS, they are published annually in this report series entitled ``Water Resources Data--Ohio.`` This report (in two volumes) includes records on surface water and ground water in the State. Specifically, it contains: (1) Discharge records for streamflow-gaging stations, miscellaneous sites, and crest-stage stations; (2) stage and content records for streams, lakes, and reservoirs; (3) water-quality data for streamflow-gaging stations, wells, synoptic sites, and partial-record sit -aid (4) water-level data for observation wells. Locations of lake-and streamflow-gaging stations, water-quality stations, and observation wells for which data are presented in this volume are shown in figures 8a through 8b. The data in this report represent that part of the National Water Data System collected by the USGS and cooperating State and Federal agencies in Ohio. This series of annual reports for Ohio began with the 1961 water year with a report that contained only data relating to the quantities of surface water. For the 1964 water year, a similar report was introduced that contained only data relating to water quality. Beginning with the 1975 water year, the report was changed to present (in two or three volumes) data on quantities of surface water, quality of surface and ground water, and ground-water levels.

  16. Natural Radioactivity Pattern of Surabaya Water Environmental Samples

    International Nuclear Information System (INIS)

    Rosidi; Agus Taftazani

    2007-01-01

    The gross β radioactivity and natural radionuclide of Surabaya environmental samples pattern have been evaluated. The environmental samples were chosen randomly at 12 locations. The environment samples were water (fresh, estuary and coastal), sediment, eichhornia crassipes (Mart) Solms, Mangrove (Rhizophora stylosa), (Moolgarda delicatus) fish and (Johnius (Johnieops) borneensis) (Sharpnose hammer croaker) fish. The water sample was evaporated; the sediment sample was dried and ground; the biotic samples was burnt at the temperature 500 °C ; The gross β measurement using GM detector and the radionuclides has been identified by γ spectrometer. From the investigation results could be concluded that the natural radioactivity of environmental samples was very low. gross-β of water samples were lower than the threshold value of local government regulation of Surabaya no: 2 year 2004 (1 Bq/L). The distribution of gross-β activity of eichhornia crassipes (Mart) Solms was higher than the other biotic, water and sediment samples as well as the accumulation of radionuclides in the water organism was taken place. The result of identification using γ spectrometer has detected 7 of radionuclides, i.e 210 Pb, 212 Pb, 214 Pb, 208 Tl, 214 Bi, 228 Ac, and 40 K in all sample. The distribution factor of sediment F D was less than bioaccumulation factor of biotic F B and it indicates that there the radionuclide accumulation migration follows the pattern of water - sediment - biotic sample. (author)

  17. Sampling procedure, receipt and conservation of water samples to determine environmental radioactivity

    International Nuclear Information System (INIS)

    Herranz, M.; Navarro, E.; Payeras, J.

    2009-01-01

    The present document informs about essential goals, processes and contents that the subgroups Sampling and Samples Preparation and Conservation believe they should be part of the procedure to obtain a correct sampling, receipt, conservation and preparation of samples of continental, marine and waste water before qualifying its radioactive content.

  18. Radioactivity in waste water samples from COGEMA supplied by Greenpeace

    International Nuclear Information System (INIS)

    Reinen, H.A.J.M.; Kwakman, P.J.M.; Overwater, R.M.W.; Tax, R.B.; Nissan, L.A.

    1999-01-01

    The environmental organization Greenpeace sampled waste water from the reprocessing plant COGEMA in La Hague, France, in May 1999. On request of the Inspection Environmental Hygiene, The Dutch National Institute for Public Health and Environmental Protection (RIVM) determined the radioactivity of the waste water samples. 5 refs

  19. Determination of Phenols in Water Samples using a Supported ...

    African Journals Online (AJOL)

    The sample preparation method was tested for the determination of phenols in river water samples and landfill leachate. Concentrations of phenols in river water were found to be in the range 4.2 μg L–1 for 2-chlorophenol to 50 μg L–1 for 4-chlorophenol. In landfill leachate, 4-chlorophenol was detected at a concentration ...

  20. Measurement of 90Sr in fresh water samples

    International Nuclear Information System (INIS)

    Belanova, A.; Meresova, J.; Svetlik, I.; Tomaskova, L.

    2008-01-01

    This preliminary study show new experimental approach to the determination of the radionuclide 90 Sr in water samples. The new method of dynamic windows utilizing liquid scintillation counting was applied on model and surface water samples. Our results show the demand of separation technique with significantly higher yields. (authors)

  1. Sampling procedure for lake or stream surface water chemistry

    Science.gov (United States)

    Robert Musselman

    2012-01-01

    Surface waters collected in the field for chemical analyses are easily contaminated. This research note presents a step-by-step detailed description of how to avoid sample contamination when field collecting, processing, and transporting surface water samples for laboratory analysis.

  2. UMTRA project water sampling and analysis plan, Grand Junction, Colorado

    International Nuclear Information System (INIS)

    1994-07-01

    Surface remedial action will be completed at the Grand Junction processing site during the summer of 1994. Results of 1993 water sampling indicate that ground water flow conditions and ground water quality at the processing site have remained relatively constant with time. Uranium concentrations in ground water continue to exceed the maximum concentration limits, providing the best indication of the extent of contaminated ground water. Evaluation of surface water quality of the Colorado River indicate no impact from uranium processing activities. No compliance monitoring at the Cheney disposal site has been proposed because ground water in the Dakota Sandstone (uppermost aquifer) is classified as limited-use (Class 111) and because the disposal cell is hydrogeologically isolated from the uppermost aquifer. The following water sampling and water level monitoring activities are planned for calendar year 1994: (i) Semiannual (early summer and late fall) sampling of six existing monitor wells at the former Grand Junction processing site. Analytical results from this sampling will be used to continue characterizing hydrogeochemical trends in background ground water quality and in the contaminated ground water area resulting from source term (tailings) removal. (ii) Water level monitoring of approximately three proposed monitor wells projected to be installed in the alluvium at the processing site in September 1994. Data loggers will be installed in these wells, and water levels will be electronically monitored six times a day. These long-term, continuous ground water level data will be collected to better understand the relationship between surface and ground water at the site. Water level and water quality data eventually will be used in future ground water modeling to establish boundary conditions in the vicinity of the Grand Junction processing site. Modeling results will be used to help demonstrate and document the potential remedial alternative of natural flushing

  3. Sample to moderator volume ratio effects in neutron yield from a PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia); Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia); Khateeb-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia)

    2007-02-15

    Performance of a prompt gamma ray neutron activation analysis (PGNAA) setup depends upon thermal neutron yield at the PGNAA sample location. For a moderator, which encloses a sample, thermal neutron intensity depends upon the effective moderator volume excluding the void volume due to sample volume. A rectangular moderator assembly has been designed for the King Fahd University of Petroleum and Minerals (KFUPM) PGNAA setup. The thermal and fast neutron yield has been measured inside the sample cavity as a function of its front moderator thickness using alpha particle tracks density and recoil proton track density inside the CR-39 nuclear track detectors (NTDs). The thermal/fast neutron yield ratio, obtained from the alpha particle tracks density to proton tracks density ratio in the NTDs, shows an inverse correlation with sample to moderator volume ratio. Comparison of the present results with the previously published results of smaller moderators of the KFUPM PGNAA setup confirms the observation.

  4. Sampling based motion planning with reachable volumes: Application to manipulators and closed chain systems

    KAUST Repository

    McMahon, Troy

    2014-09-01

    © 2014 IEEE. Reachable volumes are a geometric representation of the regions the joints of a robot can reach. They can be used to generate constraint satisfying samples for problems including complicated linkage robots (e.g. closed chains and graspers). They can also be used to assist robot operators and to help in robot design.We show that reachable volumes have an O(1) complexity in unconstrained problems as well as in many constrained problems. We also show that reachable volumes can be computed in linear time and that reachable volume samples can be generated in linear time in problems without constraints. We experimentally validate reachable volume sampling, both with and without constraints on end effectors and/or internal joints. We show that reachable volume samples are less likely to be invalid due to self-collisions, making reachable volume sampling significantly more efficient for higher dimensional problems. We also show that these samples are easier to connect than others, resulting in better connected roadmaps. We demonstrate that our method can be applied to 262-dof, multi-loop, and tree-like linkages including combinations of planar, prismatic and spherical joints. In contrast, existing methods either cannot be used for these problems or do not produce good quality solutions.

  5. Sampling based motion planning with reachable volumes: Application to manipulators and closed chain systems

    KAUST Repository

    McMahon, Troy; Thomas, Shawna; Amato, Nancy M.

    2014-01-01

    © 2014 IEEE. Reachable volumes are a geometric representation of the regions the joints of a robot can reach. They can be used to generate constraint satisfying samples for problems including complicated linkage robots (e.g. closed chains and graspers). They can also be used to assist robot operators and to help in robot design.We show that reachable volumes have an O(1) complexity in unconstrained problems as well as in many constrained problems. We also show that reachable volumes can be computed in linear time and that reachable volume samples can be generated in linear time in problems without constraints. We experimentally validate reachable volume sampling, both with and without constraints on end effectors and/or internal joints. We show that reachable volume samples are less likely to be invalid due to self-collisions, making reachable volume sampling significantly more efficient for higher dimensional problems. We also show that these samples are easier to connect than others, resulting in better connected roadmaps. We demonstrate that our method can be applied to 262-dof, multi-loop, and tree-like linkages including combinations of planar, prismatic and spherical joints. In contrast, existing methods either cannot be used for these problems or do not produce good quality solutions.

  6. Comparison of uncertainties related to standardization of urine samples with volume and creatinine concentration

    DEFF Research Database (Denmark)

    Garde, Anne Helene; Hansen, Ase Marie; Kristiansen, Jesper

    2004-01-01

    When measuring biomarkers in urine, volume (and time) or concentration of creatinine are both accepted methods of standardization for diuresis. Both types of standardization contribute uncertainty to the final result. The aim of the present paper was to compare the uncertainty introduced when usi...... increase in convenience for the participants, when collecting small volumes rather than complete 24 h samples....... the two types of standardization on 24 h samples from healthy individuals. Estimates of uncertainties were based on results from the literature supplemented with data from our own studies. Only the difference in uncertainty related to the two standardization methods was evaluated. It was found...... that the uncertainty associated with creatinine standardization (19-35%) was higher than the uncertainty related to volume standardization (up to 10%, when not correcting for deviations from 24 h) for 24 h urine samples. However, volume standardization introduced an average bias of 4% due to missed volumes...

  7. High - velocity water jet impact on concrete samples

    Czech Academy of Sciences Publication Activity Database

    Mádr, V.; Uhlář, R.; Hlaváč, L. M.; Sitek, Libor; Foldyna, Josef; Hela, R.; Bodnárová, L.; Kaličinský, J.

    2009-01-01

    Roč. 2, č. 4 (2009), s. 43-48 ISSN 2067-3809 Institutional research plan: CEZ:AV0Z30860518 Keywords : water jet * concrete * depth of penetration * disintegration volume Subject RIV: JM - Building Engineering http://acta.fih.upt.ro/pdf/2009-4/ACTA-2009-4-08.pdf

  8. Monitoring and sampling perched ground water in a basaltic terrain

    International Nuclear Information System (INIS)

    Hubbell, J.M.

    1990-01-01

    Perched ground water zones can provide significant information on water and contaminant movement. This paper presents information about perched ground water obtained from drilling and monitoring at a hazardous and radioactive waste disposal site at the Idaho National Engineering Laboratory. Six of forty-five wells drilled at the Radioactive Waste Management Complex have detected perched water in basalts above sedimentary interbeds. This paper describes the distribution and characteristics of perched ground water. It discusses perched water below the surficial sediments in wells at the RWMC, the characteristics of chemical constituents found in perched water, the implications for contaminant transport in the unsaturated zone of water, and the lateral extent of perched water. Recommendations are made to increase the probability of detecting and sampling low yield perched water zones. 6 refs., 6 figs., 2 tabs

  9. Soil Gas Sample Handling: Evaluation of Water Removal and Sample Ganging

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Abrecht, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hayes, James C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mendoza, Donaldo P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-10-31

    Soil gas sampling is currently conducted in support of Nuclear Test Ban treaty verification. Soil gas samples are collected and analyzed for isotopes of interest. Some issues that can impact sampling and analysis of these samples are excess moisture and sample processing time. Here we discuss three potential improvements to the current sampling protocol; a desiccant for water removal, use of molecular sieve to remove CO2 from the sample during collection, and a ganging manifold to allow composite analysis of multiple samples.

  10. UMTRA water sampling and analysis plan, Tuba City, Arizona

    International Nuclear Information System (INIS)

    1993-09-01

    The purpose of this document is to provide background, guidance, and justification for fiscal year (FY) 1994 water sampling activities for the uranium mil tailings site at Tuba City, Arizona. This sampling and analysis plan will form the basis for groundwater sampling and analysis work orders to be implemented in FY94

  11. Water resources data, Ohio: Water year 1991. Volume 1, Ohio River Basin excluding project data

    Energy Technology Data Exchange (ETDEWEB)

    Shindel, H.L.; Klingler, J.H.; Mangus, J.P.; Trimble, L.E.

    1992-03-01

    Water-resources data for the 1991 water year for Ohio consist of records of stage, discharge, and water quality of streams; stage and contents of lakes and reservoirs; and water levels and water quality of ground-water wells. This report, in two volumes, contains records for water discharge at 131 gaging stations, 378 wells, and 74 partial-record sites; and water levels at 431 observation wells. Also included are data from miscellaneous sites. Additional water data were collected at various sites not involved in the systematic data-collection program and are published as miscellaneous measurements and analyses. These data represent that part of the National Water Data System collected by the US Geological Survey and cooperating State and Federal agencies in Ohio.

  12. Water sampling device for fuel rod failure monitoring

    International Nuclear Information System (INIS)

    Oogami, Hideaki; Echigoya, Hironori; Matsuoka, Tesshi.

    1991-01-01

    The device of the present invention accurately samples coolants in a channel box as sampling water even if the upper end of the channel box of a fuel assembly is positioned at the same height or lower than the upper end of an upper lattice plate. An existent device comprises an outer cap, an inner cap, an air supply pipe and a water sampling tube. In addition, the device of the present invention comprises a sealing material disposed at the end of the outer cap for keeping liquid sealing with the upper lattice plate and a water level monitoring pipe extended to lower than the inner cap passing through the liquid sealing of the outer cap for sucking the atmosphere in the outer cap. Pressurized air is sent through the air supply pipe, to lower the water level of the coolants in the outer cap and the water level monitoring pipe sucks the pressurized air, by which the inside and the outside of the channel box are partitioned. Subsequently, if the sample water is sampled by a sampling tube, sampling water which enables accurate evaluation for radioactivity concentration in the fuel assembly can be obtained. (I.S.)

  13. UMTRA project water sampling and analysis plan, Tuba City, Arizona

    International Nuclear Information System (INIS)

    1996-02-01

    Planned, routine ground water sampling activities at the U.S. Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site in Tuba City, Arizona, are described in the following sections of this water sampling and analysis plan (WSAP). This plan identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the stations routinely monitored at the site. The ground water data are used for site characterization and risk assessment. The regulatory basis for routine ground water monitoring at UMTRA Project sites is derived from the U.S. Environmental Protection Agency (EPA) regulations in 40 CFR Part 192 (1994) and the final EPA standards of 1995 (60 FR 2854). Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), and the most effective technical approach for the site

  14. Monitoring and sampling perched ground water in a basaltic terrain

    International Nuclear Information System (INIS)

    Hubbell, J.M.

    1990-01-01

    Perched ground water zones are often overlooked in monitoring plans, but they can provide significant information on water and contaminant movement. This paper presents information about perched ground water obtained from drilling and monitoring at a hazardous and radioactive waste disposal site at the Idaho National Engineering Laboratory. Six of forty-five wells drilled at the Radioactive Waste Management Complex have detected perched water in basalts above sedimentary interbeds. Perched water has been detected at depths of 90 and 210 ft below land surface, approximately 370 ft above the regional water table. Eighteen years of water level measurements from one well at a depth of 210 ft indicate a consistent source of water. Water level data indicate a seasonal fluctuation. The maximum water level in this well varies within a 0.5 ft interval, suggesting the water level reaches equilibrium with the inflow to the well at this height. Volatile organic constituents have been detected in concentrations from 1.2 to 1.4 mg/L of carbon tetrachloride. Eight other volatile organics have been detected. The concentrations of organics are consistent with the prevailing theory of movement by diffusion in the gaseous phase. Results of tritium analyses indicate water has moved to a depth of 86 ft in 17 yr. Results of well sampling analyses indicate monitoring and sampling of perched water can be a valuable resource for understanding the hydrogeologic environment of the vadose zone at disposal sites

  15. Pre-concentration of uranium from water samples by dispersive liquid-liquid micro-extraction

    Energy Technology Data Exchange (ETDEWEB)

    Khajeh, Mostafa; Nemch, Tabandeh Karimi [Zabol Univ. (Iran, Islamic Republic of). Dept. of Chemistry

    2014-07-01

    In this study, a simple and rapid dispersive liquid-liquid microextraction (DLLME) was developed for the determination of uranium in water samples prior to high performance liquid chromatography with diode array detection. 1-(2-pyridylazo)-2-naphthol (PAN) was used as complexing agent. The effect of various parameters on the extraction step including type and volume of extraction and dispersive solvents, pH of solution, concentration of PAN, extraction time, sample volume and ionic strength were studied and optimized. Under the optimum conditions, the limit of detection (LOD) and preconcentration factor were 0.3 μg L{sup -1} and 194, respectively. Furthermore, the relative standard deviation of the ten replicate was <2.6%. The developed procedure was then applied to the extraction and determination of uranium in the water samples.

  16. Pre-concentration of uranium from water samples by dispersive liquid-liquid micro-extraction

    International Nuclear Information System (INIS)

    Khajeh, Mostafa; Nemch, Tabandeh Karimi

    2014-01-01

    In this study, a simple and rapid dispersive liquid-liquid microextraction (DLLME) was developed for the determination of uranium in water samples prior to high performance liquid chromatography with diode array detection. 1-(2-pyridylazo)-2-naphthol (PAN) was used as complexing agent. The effect of various parameters on the extraction step including type and volume of extraction and dispersive solvents, pH of solution, concentration of PAN, extraction time, sample volume and ionic strength were studied and optimized. Under the optimum conditions, the limit of detection (LOD) and preconcentration factor were 0.3 μg L -1 and 194, respectively. Furthermore, the relative standard deviation of the ten replicate was <2.6%. The developed procedure was then applied to the extraction and determination of uranium in the water samples.

  17. Effect of Water Volume and Biogas Volumetric Flowrate in Biogas Purification Through Water Scrubbing Method

    Directory of Open Access Journals (Sweden)

    Hendry Sakke Tira

    2016-05-01

    Full Text Available Energy supply is a crucial issue in the world in the last few years. The increase in energy demand caused by population growth and resource depletion of world oil reserves provides determination to produce and to use renewable energies. One of the them is biogas. However, until now the use of biogas has not yet been maximized because of its poor purity. According to the above problem, the research has been carried out using the method of water absorption. Under this method it is expected that the rural community is able to apply it. Therefore, their economy and productivity can be increased. This study includes variations of absorbing water volume (V and input biogas volume flow rate (Q. Raw biogas which is flowed into the absorbent will be analyzed according to the determined absorbing water volume and input biogas volume rate. Improvement on biogas composition through the biogas purification method was obtained. The level of CO2 and H2S was reduced significantly specifically in the early minutes of purification process. On the other hand, the level of CH4 was increased improving the quality of raw biogas. However, by the time of biogas purification the composition of purified biogas was nearly similar to the raw biogas. The main reason for this result was an increasing in pH of absorbent. It was shown that higher water volume and slower biogas volume rate obtained better results in reducing the CO2 and H2S and increasing CH4 compared to those of lower water volume and higher biogas volume rate respectively. The purification method has a good promising in improving the quality of raw biogas and has advantages as it is cheap and easy to be operated.

  18. Effect of Water Volume and Biogas Volumetric Flowrate in Biogas Purification Through Water Scrubbing Method

    Directory of Open Access Journals (Sweden)

    Hendry Sakke Tira

    2014-10-01

    Full Text Available Energy supply is a crucial issue in the world in the last few years. The increase in energy demand caused by population growth and resource depletion of world oil reserves provides determination to produce and to use renewable energies. One of the them is biogas. However, until now the use of biogas has not yet been maximized because of its poor purity. According to the above problem, the research has been carried out using the method of water absorption. Under this method it is expected that the rural community is able to apply it. Therefore, their economy and productivity can be increased. This study includes variations of absorbing water volume (V and input biogas volume flow rate (Q. Raw biogas which is flowed into the absorbent will be analyzed according to the determined absorbing water volume and input biogas volume rate. Improvement on biogas composition through the biogas purification method was obtained. The level of CO2 and H2S was reduced significantly specifically in the early minutes of purification process. On the other hand, the level of CH4 was increased improving the quality of raw biogas. However, by the time of biogas purification the composition of purified biogas was nearly similar to the raw biogas. The main reason for this result was an increasing in pH of absorbent. It was shown that higher water volume and slower biogas volume rate obtained better results in reducing the CO2 and H2S and increasing CH4 compared to those of lower water volume and higher biogas volume rate respectively. The purification method has a good promising in improving the quality of raw biogas and has advantages as it is cheap and easy to be operated.

  19. UMTRA project water sampling and analysis plan, Monument Valley, Arizona

    International Nuclear Information System (INIS)

    1994-04-01

    The Monument Valley Uranium Mill Tailings Remedial Action (UMTRA) Project site in Cane Valley is a former uranium mill that has undergone surface remediation in the form of tailings and contaminated materials removal. Contaminated materials from the Monument Valley (Arizona) UMTRA Project site have been transported to the Mexican Hat (Utah) UMTRA Project site for consolidation with the Mexican Hat tailings. Tailings removal was completed in February 1994. Three geologic units at the site contain water: the unconsolidated eolian and alluvial deposits (alluvial aquifer), the Shinarump Conglomerate (Shinarump Member), and the De Chelly Sandstone. Water quality analyses indicate the contaminant plume has migrated north of the site and is mainly in the alluvial aquifer. An upward hydraulic gradient in the De Chelly Sandstone provides some protection to that aquifer. This water sampling and analysis plan recommends sampling domestic wells, monitor wells, and surface water in April and September 1994. The purpose of sampling is to continue periodic monitoring for the surface program, evaluate changes to water quality for site characterization, and provide data for the baseline risk assessment. Samples taken in April will be representative of high ground water levels and samples taken in September will be representative of low ground water levels. Filtered and nonfiltered samples will be analyzed for plume indicator parameters and baseline risk assessment parameters

  20. Radon in water samples around Ningyo Toge area

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Sadaaki [Power Reactor and Nuclear Fuel Development Corp., Kamisaibara, Okayama (Japan). Ningyo Toge Works

    1997-02-01

    Radon concentrations of river water and drinking water were surveyed. Water samples were collected from the region around Ningyo-Toge Works which were positioned on a granitic layer having uranium deposit. Each sample was taken using a separating funnel and the radioactivity was counted by liquid scintillation counter (ALOKA, LB-2). Since there were old working places of mine in the region, mine drainages from them were also analyzed. The radon concentration of drinking water from the region ranged from 0.1 to 230 Bq/l. The samples with a higher activity than 100 Bq/l were water from springs or wells and the area of the highest Rn concentration was on a typical granitic layer, suggesting some geographic effects on Rn concentration. Some samples of drinking water had slightly higher levels of Rn, probably due to the utilization of underflow as its source. The mean concentration of Rn became higher in the order; river water, drinking water, mine drainage in the region. In addition, a negative correlation between Rn concentration of water and the river flow rate was observed in this region. (M.N.)

  1. Water resources data, Ohio: Water year 1991. Volume 2, St. Lawrence River Basin: Statewide project data

    Energy Technology Data Exchange (ETDEWEB)

    Shindel, H.L.; Klingler, J.H.; Mangus, J.P.; Trimble, L.E.

    1992-03-01

    The Water Resources Division of the US Geological Survey (USGS), in cooperation with State agencies, obtains a large amount of data pertaining to the water resources of Ohio each water year. These data, accumulated during many years, constitute a valuable data base for developing an improved understanding of the water resources of the State. To make these data readily available to interested parties outside the USGS, the data are published annually in this report series entitled ``Water Resources Data--Ohio.`` This report (in two volumes) includes records on surface water and ground water in the State. Specifically, it contains: (1) Discharge records for 131 streamflow-gaging stations, 95 miscellaneous sites; (2) stage and content records for 5 streams, lakes, and reservoirs; (3) water-quality for 40 streamflow-gaging stations, 378 wells, and 74 partial-record sites; and (4) water levels for 431 observation wells.

  2. Mathematical simulation of water distillation column for decreasing volume of tritiated water

    International Nuclear Information System (INIS)

    Kinoshita, Masahiro; Naruse, Yuji

    1981-12-01

    Water distillation is an attractive method for decreasing volume of the tritiated water produced by operation of tritium facilities. The tritiated water is continuously fed to a column and it is separated into two streams. The top stream is discarded to the environment after addition of sufficient amount of uncontaminated water. The bottom stream is further treated for solidification and capsulation. The tridiagonal matrix method proved to provide surprisingly rapid convergences of the calculations. The concentration of deuterium naturally contained in the tritiated water is higher than the tritium concentration, but it was verified that presence of HDO can be ignored in the calculation. (author)

  3. Biotreatment of produced waters for volume reduction and contaminant removal

    Energy Technology Data Exchange (ETDEWEB)

    Negri, M.C.; Hinchman, R.R. [Argonne National Lab., IL (United States); Mollock, J. [Devon Energy Corp., Oklahoma City, OK (United States)

    1997-10-01

    Produced water is wastewater that is brought to the surface from natural gas wells during natural gas production. Its constituents, mostly salt, with traces of hydrocarbons and heavy metals, are a significant disposal problem. Argonne National Laboratory (ANL), in partnership with the Gas Research Institute (GRI), has developed a low-cost, low-tech method, in which green plants are used to reduce the volume of produced water. The authors have designed an engineered bioreactor system, which is modeled after natural saline wetland ecosystems. The plant bioreactor system maximizes plant evapotranspiration to reduce wastewater volume and, concurrently, may function as a biological filter to enhance contaminant degradation and immobilization in the root/rhizosphere zone. Halophyte plant species having high salt tolerance and high transpiration rates were selected after they tested them in greenhouse experiments. Models obtained by using their greenhouse findings reduced the volume of the wastewater (up to 6% salt) by 75% in about 8 days. A field demonstration of the bioreactor, designed on the basis of the results from the greenhouse study, is successfully under way at a natural gas well site in Oklahoma. The process could offer the petroleum industry a low-cost biological alternative to existing expensive options.

  4. A QUANTITATIVE EVALUATION OF THE WATER DISTRIBUTION IN A SOIL SAMPLE USING NEUTRON IMAGING

    Directory of Open Access Journals (Sweden)

    Jan Šácha

    2016-10-01

    Full Text Available This paper presents an empirical method by Kang et al. recently proposed for correcting two-dimensional neutron radiography for water quantification in soil. The method was tested on data from neutron imaging of the water infiltration in a soil sample. The raw data were affected by neutron scattering and by beam hardening artefacts. Two strategies for identifying the correction parameters are proposed in this paper. The method has been further developed for the case of three-dimensional neutron tomography. In a related experiment, neutron imaging is used to record ponded-infiltration experiments in two artificial soil samples. Radiograms, i.e., two-dimensional projections of the sample, were acquired during infiltration. A calculation was made of the amount of water and its distribution within the radiograms, in the form of two-dimensional water thickness maps. Tomograms were reconstructed from the corrected and uncorrected water thickness maps to obtain the 3D spatial distribution of the water content within the sample. Without the correction, the beam hardening and the scattering effects overestimated the water content values close to the perimeter of the sample, and at the same time underestimated the values close to the centre of the sample. The total water content of the entire sample was the same in both cases. The empirical correction method presented in this study is a relatively accurate, rapid and simple way to obtain the quantitatively determined water content from two-dimensional and three-dimensional neutron images. However, an independent method for measuring the total water volume in the sample is needed in order to identify the correction parameters.

  5. Sampling and Analysis Plan for the 105-N Basin Water

    International Nuclear Information System (INIS)

    R.O. Mahood

    1997-01-01

    This sampling and analysis plan defines the strategy, and field and laboratory methods that will be used to characterize 105-N Basin water. The water will be shipped to the 200 Area Effluent Treatment Facility for treatment and disposal as part of N Reactor deactivation. These analyses are necessary to ensure that the water will meet the acceptance criteria of the ETF, as established in the Memorandum of Understanding for storage and treatment of water from N-Basin (Appendix A), and the characterization requirements for 100-N Area water provided in a letter from ETF personnel (Appendix B)

  6. Validation of single-sample doubly labeled water method

    International Nuclear Information System (INIS)

    Webster, M.D.; Weathers, W.W.

    1989-01-01

    We have experimentally validated a single-sample variant of the doubly labeled water method for measuring metabolic rate and water turnover in a very small passerine bird, the verdin (Auriparus flaviceps). We measured CO 2 production using the Haldane gravimetric technique and compared these values with estimates derived from isotopic data. Doubly labeled water results based on the one-sample calculations differed from Haldane values by less than 0.5% on average (range -8.3 to 11.2%, n = 9). Water flux computed by the single-sample method differed by -1.5% on average from results for the same birds based on the standard, two-sample technique (range -13.7 to 2.0%, n = 9)

  7. Preconcentration of uranium in water samples using dispersive ...

    African Journals Online (AJOL)

    Preconcentration of uranium in water samples using dispersive liquid-liquid micro- extraction coupled with solid-phase extraction and determination with inductively coupled plasma-optical emission spectrometry.

  8. Study on water boiling noises in a large volume

    International Nuclear Information System (INIS)

    Masagutov, R.F.; Krivtsov, V.A.

    1977-01-01

    Presented are the results of measurement of the noise spectra during boiling of water in a large volume at the pressure of 1 at. Boiling of the distilled water has been accomplished with the use of the heaters made of the Kh18N10T steel, 50 mm in length, 2 mm in the outside diameter, with the wall thickness of 0.1 mm. The degree of water under heating changed during the experiments from 0 to 80 deg C, and the magnitude of the specific heat flux varied from o to 0.7 - 0.9 qsup(x), where qsup(x) was the specific heat flux of the tube burn-out. The noise spectrum of the boiling water was analyzed at frequencies of 0.5 to 200 kHz. The submerge-type pressure-electric transmitters were used for measurements. At underheating boiling during the experiment the standing waves have formed which determine the structure of the measured spectra. During saturated boiling of water no standing waves were revealed. At underheating over 15 - 20 deg C the water boiling process is accompanied by the noises within the ultrasonic frequency range. The maximum upper boundary of the noise in the experiments amounts to 90 - 100 kHz

  9. Comprehensive Cooling Water Study. Volume 1. Summary of environmental effects, Savannah River Plant. Annual report

    International Nuclear Information System (INIS)

    Gladden, J.B.; Lower, M.W.; Mackey, H.E.; Specht, W.L.; Wilde, E.W.

    1985-07-01

    This volume summarizes the technical content of Volumes II through XI of the annual report. Volume II provides a description of the SRP environment, facilities, and operation, and presents the objectives and design for the CCWS. Volume III presents information on water quality of SRP surface waters. Results of radionuclide and heavy metal transport studies are presented in Volume IV. Volume V contains findings from studies of wetland plant communities. Volume VI presents findings from studies of the lower food chain components of SRP aquatic habitats. The results of fisheries studies are reported in Volume VII. Studies of semi-aquatic vertebrate populations are reported in Volume VIII. Water-fowl utilization of SRP habitats is discussed in Volume IX. The status of endangered species that utilize SRP aquatic habitats is presented in Volume X. The findings from studies of Parr Pond ecosystem are presented in Volume XI

  10. Thirteenth water reactor safety research information meeting: proceedings Volume 1

    International Nuclear Information System (INIS)

    Weiss, A.J.

    1986-02-01

    This six-volume report contains 151 papers out of the 178 that were presented at the Thirteenth Water Reactor Safety Research Information Meeting held at the National Bureau of Standards, Gaithersburg, Maryland, during the week of October 22-25, 1985. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included thirty-one different papers presented by researchers from Japan, Canada and eight European countries. The title of the papers and the names of the authors have been updated and may differ from those that appeared in the final program of the meeting. This volume presents information on: risk analysis PRA application; severe accident sequence analysis; risk analysis/dependent failure analysis; and industry safety research

  11. A high volume sampling system for isotope determination of volatile halocarbons and hydrocarbons

    Directory of Open Access Journals (Sweden)

    E. Bahlmann

    2011-10-01

    Full Text Available The isotopic composition of volatile organic compounds (VOCs can provide valuable information on their sources and fate not deducible from mixing ratios alone. In particular the reported carbon stable isotope ratios of chloromethane and bromomethane from different sources cover a δ13C-range of almost 100‰ making isotope ratios a very promising tool for studying the biogeochemistry of these compounds. So far, the determination of the isotopic composition of C1 and C2 halocarbons others than chloromethane is hampered by their low mixing ratios.

    In order to determine the carbon isotopic composition of C1 and C2 halocarbons with mixing ratios as low as 1 pptv (i a field suitable cryogenic high volume sampling system and (ii a chromatographic set up for processing these samples have been developed and validated. The sampling system was tested at two different sampling sites, an urban and a coastal location in Northern Germany. The average δ13C-values for bromomethane at the urban site were −42.9 ± 1.1‰ and agreed well with previously published results. But at the coastal site bromomethane was substantially enriched in 13C by almost 10‰. Less pronounced differences were observed for chlorodifluoromethane, 1,1,1-trichloroethane and chloromethane. We suggest that these differences are related to the turnover of these compounds in ocean surface waters. Furthermore we report first carbon isotope ratios for iodomethane (−40.4‰ to −79.8‰, bromoform (−13.8‰ to 22.9‰, and other halocarbons.

  12. bacteriological analysis of well water samples in sagamu.

    African Journals Online (AJOL)

    Dr Oboro VO

    Department of Pharmaceutical Microbiology, Faculty of Pharmacy, Olabisi Onabanjo University, Ago-Iwoye, Nigeria. *Correspondence. ... All the water samples exceeded the standard limit of the most probable ... or disinfection and this could lead to outbreak of water borne diseases. ... The bottle was brought up to a surface.

  13. Contamination of Ground Water Samples from Well Installations

    DEFF Research Database (Denmark)

    Grøn, Christian; Madsen, Jørgen Øgaard; Simonsen, Y.

    1996-01-01

    Leaching of a plasticizer, N-butylbenzenesulfonamide, from ground water multilevel sampling installations in nylon has been demonstrated. The leaching resulted in concentrations of DOC and apparent AOX, both comparable with those observed in landfill contaminated ground waters. It is concluded...... that nylon should not be used in studies of contamination with organic compounds....

  14. Bacterial contamination of water samples in Gabon, 2013

    Directory of Open Access Journals (Sweden)

    Jonas Ehrhardt

    2017-10-01

    Full Text Available Contamination of water is a major burden in the public health setting of developing countries. We therefore assessed the quality of water samples in Gabon in 2013. The main findings were a contamination rate with coliforms of 13.5% and the detection of a possible environmental reservoir for extended spectrum beta-lactamase-producing bacteria.

  15. Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples

    OpenAIRE

    Nataša Gros

    2013-01-01

    This review focuses on the ion chromatographic methods for the analyses of natural waters with high ionic strength. At the beginning a natural diversity in ionic composition of waters is highlighted and terminology clarified. In continuation a brief overview of other review articles of potential interest is given. A review of ion chromatographic methods is organized in four sections. The first section comprises articles focused on the determination of ionic composition of water samples as com...

  16. Reduction of hexavalent chromium in water samples acidified for preservation

    Science.gov (United States)

    Stollenwerk, K.G.; Grove, D.B.

    1985-01-01

    Reduction of hexavalent chromium, Cr(VI), in water samples, preserved by standard techniques, was investigated. The standard preservation technique for water samples that are to be analyzed for Cr(VI) consists of filtration through a 0.45-??m membrane, acidification to a pH plastic bottles. Batch experiments were conducted to evaluate the effect of H+ concentration, NO2, temperature, and dissolved organic carbon (DOC) on the reduction of Cr(VI) to Cr(III). The rate of reduction of Cr(VI) to Cr(III) increased with increasing NO2, DOC, H+, and temperature. Reduction of Cr(VI) by organic matter occurred in some samples even though the samples were unacidified. Reduction of Cr(VI) is inhibited to an extent by storing the sample at 4??C. Stability of Cr(VI) in water is variable and depends on the other constituents present in the sample. Water samples collected for the determination of Cr(VI) should be filtered (0.45-??m membrane), refrigerated, and analyzed as quickly as possible. Water samples should not be acidified. Measurement of total Cr in addition to Cr(VI) can serve as a check for Cr(VI) reduction. If total Cr is greater than Cr(VI), the possibility that Cr(VI) reduction has occurred needs to be considered.The rate of reduction of Cr(VI) to Cr(III) increased with increasing NO//2, DOC, H** plus , and temperature. Reduction of Cr(VI) by organic matter occurred in some samples even though the samples were unacidified. Reduction of Cr(VI) is inhibited to an extent by storing the sample at 4 degree C. Stability of Cr(VI) in water is variable and depends on the other constituents present in the sample. Water samples collected for the determination of Cr(VI) should be filtered (0. 45- mu m membrane), refrigerated, and analyzed as quickly as possible. Water samples should not be acidified. Measurement of total Cr in addition to Cr(VI) can serve as a check for Cr(VI) reduction. If total Cr is greater than Cr(VI), the possibility that Cr(VI) reduction has occurred needs

  17. Absolute activity determinations on large volume geological samples independent of self-absorption effects

    International Nuclear Information System (INIS)

    Wilson, W.E.

    1980-01-01

    This paper describes a method for measuring the absolute activity of large volume samples by γ-spectroscopy independent of self-absorption effects using Ge detectors. The method yields accurate matrix independent results at the expense of replicative counting of the unknown sample. (orig./HP)

  18. Sample volume and alignment analysis for an optical particle counter sizer, and other applications

    International Nuclear Information System (INIS)

    Holve, D.J.; Davis, G.W.

    1985-01-01

    Optical methods for particle size distribution measurements in practical high temperature environments are approaching feasibility and offer significant advantages over conventional sampling methods. A key requirement of single particle counting techniques is the need to know features of the sample volume intensity distribution which in general are a function of the particle scattering properties and optical system geometry. In addition, the sample volume intensity distribution is sensitive to system alignment and thus calculations of alignment sensitivity are required for assessment of practical alignment tolerances. To this end, an analysis of sample volume characteristics for single particle counters in general has been developed. Results from the theory are compared with experimental measurements and shown to be in good agreement. A parametric sensitivity analysis is performed and a criterion for allowable optical misalignment is derived for conditions where beam steering caused by fluctuating refractive-index gradients is significant

  19. UMTRA project water sampling and analysis plan, Mexican Hat, Utah

    International Nuclear Information System (INIS)

    1994-04-01

    The Mexican Hat, Utah, Uranium Mill Tailings Remedial Action (UMTRA) Project site is a former uranium mill that is undergoing surface remediation in the form of on-site tailings stabilization. Contaminated surface materials from the Monument Valley, Arizona, UMTRA Project site have been transported to the Mexican Hat site and are being consolidated with the Mexican Hat tailings. The scheduled completion of the tailings disposal cell is August 1995. Water is found in two geologic units at the site: the Halgaito Shale Formation and the Honaker Trail Formation. The tailings rest on the Halgaito Shale, and water contained in that unit is a result of milling activities and, to a lesser extent, water released from the tailings from compaction during remedial action construction of the disposal cell. Water in the Halgaito Shale flows through fractures and discharges at seeps along nearby arroyos. Flow from the seeps will diminish as water drains from the unit. Ground water in the lower unit, the Honaker Trail Formation, is protected from contamination by an upward hydraulic gradient. There are no nearby water supply wells because of widespread poor background ground water quality and quantity, and the San Juan River shows no impacts from the site. This water sampling and analysis plan (WSAP) recommends sampling six seeps and one upgradient monitor well compared in the Honaker Trail Formation. Samples will be taken in April 1994 (representative of high group water levels) and September 1994 (representative of low ground water levels). Analyses will be performed on filtered samples for plume indicator parameters

  20. Nuclear powerplant standardization: light water reactors. Volume 2. Appendixes

    International Nuclear Information System (INIS)

    1981-06-01

    This volume contains working papers written for OTA to assist in preparation of the report, NUCLEAR POWERPLANT STANDARDIZATION: LIGHT WATER REACTORS. Included in the appendixes are the following: the current state of standardization, an application of the principles of the Naval Reactors Program to commercial reactors; the NRC and standardization, impacts of nuclear powerplant standardization on public health and safety, descriptions of current control room designs and Duke Power's letter, Admiral Rickover's testimony, a history of standardization in the NRC, and details on the impact of standardization on public health and safety

  1. Heavy water standards. Qualitative analyses, sample treating, stocking and manipulation

    International Nuclear Information System (INIS)

    Pavelescu, M.; Steflea, D.; Mihancea, I.; Varlam, M.; Irimescu, R.

    1995-01-01

    This paper presents methods and procedures for measuring heavy water concentration, and also sampling, stocking and handling of samples to be analysed. The main concentration analysis methods are: mass spectrometry, for concentrations less then 1%, densitometry, for concentrations within the range 1% - 99% and infrared spectrometry for concentrations above 99%. Procedures of sampling, processing and purification appropriate to these measuring methods were established. 1 Tab

  2. Major inorganic elements in tap water samples in Peninsular Malaysia.

    Science.gov (United States)

    Azrina, A; Khoo, H E; Idris, M A; Amin, I; Razman, M R

    2011-08-01

    Quality drinking water should be free from harmful levels of impurities such as heavy metals and other inorganic elements. Samples of tap water collected from 24 locations in Peninsular Malaysia were determined for inorganic element content. Minerals and heavy metals were analysed by spectroscopy methods, while non-metal elements were analysed using test kits. Minerals and heavy metals determined were sodium, magnesium, potassium, calcium, chromium, manganese, iron, nickel, copper, zinc, arsenic, cadmium and lead while the non-metal elements were fluoride, chloride, nitrate and sulphate. Most of the inorganic elements found in the samples were below the maximum permitted levels recommended by inter-national drinking water standard limits, except for iron and manganese. Iron concentration of tap water from one of the locations was higher than the standard limit. In general, tap water from different parts of Peninsular Malaysia had low concentrations of heavy metals and inorganic elements.

  3. A Volume-Limited Sample of L and T Dwarfs Defined by Parallaxes

    Science.gov (United States)

    Best, William M. J.; Liu, Michael C.; Magnier, Eugene; Dupuy, Trent

    2018-01-01

    Volume-limited samples are the gold standard for stellar population studies, as they enable unbiased measurements of space densities and luminosity functions. Parallaxes are the most direct measures of distance and are therefore essential for defining high-confidence volume limited samples. Previous efforts to model the local brown dwarf population were hampered by samples based on a small number of parallaxes. We are using UKIRT/WFCAM to conduct the largest near-infrared program to date to measure parallaxes and proper motions of L and T dwarfs. For the past 3+ years we have monitored over 350 targets, ≈90% of which are too faint to be observed by Gaia. We present preliminary results from our observations. Our program more than doubles the number of known L and T dwarf parallaxes, defining a volume-limited sample of ≈400 L0-T6 dwarfs out to 25 parsecs, the first L and T dwarf sample of this size and depth based entirely on parallaxes. Our sample will combine with the upcoming stellar census from Gaia DR2 parallaxes to form a complete volume-limited sample of nearby stars and brown dwarfs.

  4. Retrieving mesospheric water vapour from observations of volume scattering radiances

    Directory of Open Access Journals (Sweden)

    P. Vergados

    2009-02-01

    Full Text Available This study examines the possibility for a theoretical approach in the estimation of water vapour mixing ratios in the vicinity of polar mesospheric clouds (PMC using satellite observations of Volume Scattering Radiances (VSR obtained at the wavelength of 553 nm. The PMC scattering properties perturb the underlying molecular Rayleigh scattered solar radiance of the background atmosphere. As a result, the presence of PMC leads to an enhancement in the observed VSR at the altitude of the layer; the PMC VSRs are superimposed on the exponentially decreasing with height Rayleigh VSR, of the PMC-free atmosphere. The ratio between the observed and the Rayleigh VSR of the background atmosphere is used to simulate the environment in which the cloud layer is formed. In addition, a microphysical model of ice particle formation is employed to predict the PMC VSRs. The initial water vapour profile is perturbed until the modelled VSRs match the observed, at which point the corresponding temperature and water vapour profiles can be considered as a first approximation of those describing the atmosphere at the time of the observations. The role of temperature and water vapour in the cloud formation is examined by a number of sensitivity tests suggesting that the water vapour plays a dominant role in the cloud formation in agreement with experimental results. The estimated water vapour profiles are compared with independent observations to examine the model capability in the context of this study. The results obtained are in a good agreement at the peak of the PMC layer although the radiance rapidly decreases with height below the peak. This simplified scenario indicates that the technique employed can give a first approximation estimate of the water vapour mixing ratio, giving rise to the VSR observed in the presence of PMC.

  5. Rapid surface-water volume estimations in beaver ponds

    Science.gov (United States)

    Karran, Daniel J.; Westbrook, Cherie J.; Wheaton, Joseph M.; Johnston, Carol A.; Bedard-Haughn, Angela

    2017-02-01

    Beaver ponds are surface-water features that are transient through space and time. Such qualities complicate the inclusion of beaver ponds in local and regional water balances, and in hydrological models, as reliable estimates of surface-water storage are difficult to acquire without time- and labour-intensive topographic surveys. A simpler approach to overcome this challenge is needed, given the abundance of the beaver ponds in North America, Eurasia, and southern South America. We investigated whether simple morphometric characteristics derived from readily available aerial imagery or quickly measured field attributes of beaver ponds can be used to approximate surface-water storage among the range of environmental settings in which beaver ponds are found. Studied were a total of 40 beaver ponds from four different sites in North and South America. The simplified volume-area-depth (V-A-h) approach, originally developed for prairie potholes, was tested. With only two measurements of pond depth and corresponding surface area, this method estimated surface-water storage in beaver ponds within 5 % on average. Beaver pond morphometry was characterized by a median basin coefficient of 0.91, and dam length and pond surface area were strongly correlated with beaver pond storage capacity, regardless of geographic setting. These attributes provide a means for coarsely estimating surface-water storage capacity in beaver ponds. Overall, this research demonstrates that reliable estimates of surface-water storage in beaver ponds only requires simple measurements derived from aerial imagery and/or brief visits to the field. Future research efforts should be directed at incorporating these simple methods into both broader beaver-related tools and catchment-scale hydrological models.

  6. Quality-control design for surface-water sampling in the National Water-Quality Network

    Science.gov (United States)

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  7. A test of alternative estimators for volume at time 1 from remeasured point samples

    Science.gov (United States)

    Francis A. Roesch; Edwin J. Green; Charles T. Scott

    1993-01-01

    Two estimators for volume at time 1 for use with permanent horizontal point samples are evaluated. One estimator, used traditionally, uses only the trees sampled at time 1, while the second estimator, originally presented by Roesch and coauthors (F.A. Roesch, Jr., E.J. Green, and C.T. Scott. 1989. For. Sci. 35(2):281-293). takes advantage of additional sample...

  8. Relationship of land use to water quality in the Chesapeake Bay region. [water sampling and photomapping river basins

    Science.gov (United States)

    Correll, D. L.

    1978-01-01

    Both the proportions of the various land use categories present on each watershed and the specific management practices in use in each category affect the quality of runoff waters, and the water quality of the Bay. Several permanent and portable stations on various Maryland Rivers collect volume-integrated water samples. All samples are analyzed for a series of nutrient, particulate, bacterial, herbicide, and heavy metal parameters. Each basin is mapped with respect to land use by the analysis of low-elevation aerial photos. Analyses are verified and adjusted by ground truth surveys. Data are processed and stored in the Smithsonian Institution data bank. Land use categories being investigated include forests/old fields, pastureland, row crops, residential areas, upland swamps, and tidal marshes.

  9. The collection and field chemical analysis of water samples

    International Nuclear Information System (INIS)

    Korte, N.E.; Ealey, D.T.; Hollenbach, M.H.

    1984-01-01

    A successful water sampling program requires a clear understanding of appropriate measurement and sampling procedures in order to obtain reliable field data and representative samples. It is imperative that the personnel involved have a thorough knowledge of the limitations of the techniques being used. Though this seems self-evident, many sampling and field-chemical-analysis programs are still not properly conducted. Recognizing these problems, the Department of Energy contracted with Bendix Field Engineering Corporation through the Technical Measurements Center to develop and select procedures for water sampling and field chemical analysis at waste sites. The fundamental causese of poor field programs are addressed in this paper, largely through discussion of specific field-measurement techniques and their limitations. Recommendations for improvement, including quality-assurance measures, are also presented

  10. Research on How to Remove Efficiently the Condensate Water of Sampling System

    International Nuclear Information System (INIS)

    Cho, SungHwan; Kim, MinSoo; Choi, HoYoung; In, WonHo

    2015-01-01

    Corrosion was caused in the measurement chamber inside the O 2 and H 2 analyzer, and thus measuring the concentration of O 2 and H 2 was not possible. It was confirmed that the cause of the occurrence of condensate water is due to the temperature difference caused during the process of the internal gas of the disposal and degasifier tank being brought into the analyzer. Thus, a heating system was installed inside and outside of the sampling panel for gas to remove generated condensate water in the analyzer and pipe. For the case where condensate water is not removed by the heating system, drain port is also installed in the sampling panel for gas to collect the condensate water of the sampling system. It was verified that there is a great volume of condensate water existing in the pipe line during the purging process after installing manufactured goods. The condensate water was fully removed by the installed heating cable and drain port. The heating cable was operated constantly at a temperature of 80 to 90 .deg. C, which allows the precise measurement of gas concentration and longer maintenance duration by blocking of the condensate water before being produced. To install instruments for measuring the gas, such as an O 2 and H 2 analyzer etc., consideration regarding whether there condensate water is present due to the temperature difference between the measuring system and analyzer is required

  11. Research on How to Remove Efficiently the Condensate Water of Sampling System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, SungHwan; Kim, MinSoo; Choi, HoYoung; In, WonHo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Corrosion was caused in the measurement chamber inside the O{sub 2} and H{sub 2} analyzer, and thus measuring the concentration of O{sub 2} and H{sub 2} was not possible. It was confirmed that the cause of the occurrence of condensate water is due to the temperature difference caused during the process of the internal gas of the disposal and degasifier tank being brought into the analyzer. Thus, a heating system was installed inside and outside of the sampling panel for gas to remove generated condensate water in the analyzer and pipe. For the case where condensate water is not removed by the heating system, drain port is also installed in the sampling panel for gas to collect the condensate water of the sampling system. It was verified that there is a great volume of condensate water existing in the pipe line during the purging process after installing manufactured goods. The condensate water was fully removed by the installed heating cable and drain port. The heating cable was operated constantly at a temperature of 80 to 90 .deg. C, which allows the precise measurement of gas concentration and longer maintenance duration by blocking of the condensate water before being produced. To install instruments for measuring the gas, such as an O{sub 2} and H{sub 2} analyzer etc., consideration regarding whether there condensate water is present due to the temperature difference between the measuring system and analyzer is required.

  12. SyPRID sampler: A large-volume, high-resolution, autonomous, deep-ocean precision plankton sampling system

    Science.gov (United States)

    Billings, Andrew; Kaiser, Carl; Young, Craig M.; Hiebert, Laurel S.; Cole, Eli; Wagner, Jamie K. S.; Van Dover, Cindy Lee

    2017-03-01

    The current standard for large-volume (thousands of cubic meters) zooplankton sampling in the deep sea is the MOCNESS, a system of multiple opening-closing nets, typically lowered to within 50 m of the seabed and towed obliquely to the surface to obtain low-spatial-resolution samples that integrate across 10 s of meters of water depth. The SyPRID (Sentry Precision Robotic Impeller Driven) sampler is an innovative, deep-rated (6000 m) plankton sampler that partners with the Sentry Autonomous Underwater Vehicle (AUV) to obtain paired, large-volume plankton samples at specified depths and survey lines to within 1.5 m of the seabed and with simultaneous collection of sensor data. SyPRID uses a perforated Ultra-High-Molecular-Weight (UHMW) plastic tube to support a fine mesh net within an outer carbon composite tube (tube-within-a-tube design), with an axial flow pump located aft of the capture filter. The pump facilitates flow through the system and reduces or possibly eliminates the bow wave at the mouth opening. The cod end, a hollow truncated cone, is also made of UHMW plastic and includes a collection volume designed to provide an area where zooplankton can collect, out of the high flow region. SyPRID attaches as a saddle-pack to the Sentry vehicle. Sentry itself is configured with a flight control system that enables autonomous survey paths to low altitudes. In its verification deployment at the Blake Ridge Seep (2160 m) on the US Atlantic Margin, SyPRID was operated for 6 h at an altitude of 5 m. It recovered plankton samples, including delicate living larvae, from the near-bottom stratum that is seldom sampled by a typical MOCNESS tow. The prototype SyPRID and its next generations will enable studies of plankton or other particulate distributions associated with localized physico-chemical strata in the water column or above patchy habitats on the seafloor.

  13. Sampling and TDR probe insertion in the determination of the volumetric soil water content Procedimentos de amostragem e do modo de inserção no solo de sondas TDR na determinação da umidade volumétrica do solo

    Directory of Open Access Journals (Sweden)

    W. G. Teixeira

    2003-08-01

    Full Text Available Volumetric soil water content (theta can be evaluated in the field by direct or indirect methods. Among the direct, the gravimetric method is regarded as highly reliable and thus often preferred. Its main disadvantages are that sampling and laboratory procedures are labor intensive, and that the method is destructive, which makes resampling of a same point impossible. Recently, the time domain reflectometry (TDR technique has become a widely used indirect, non-destructive method to evaluate theta. In this study, evaluations of the apparent dielectric number of soils (epsilon and samplings for the gravimetrical determination of the volumetric soil water content (thetaGrav were carried out at four sites of a Xanthic Ferralsol in Manaus - Brazil. With the obtained epsilon values, theta was estimated using empirical equations (thetaTDR, and compared with thetaGrav derived from disturbed and undisturbed samples. The main objective of this study was the comparison of thetaTDR estimates of horizontally as well as vertically inserted probes with the thetaGrav values determined by disturbed and undisturbed samples. Results showed that thetaTDR estimates of vertically inserted probes and the average of horizontally measured layers were only slightly and insignificantly different. However, significant differences were found between the thetaTDR estimates of different equations and between disturbed and undisturbed samples in the thetaGrav determinations. The use of the theoretical Knight et al. model, which permits an evaluation of the soil volume assessed by TDR probes, is also discussed. It was concluded that the TDR technique, when properly calibrated, permits in situ, nondestructive measurements of q in Xanthic Ferralsols of similar accuracy as the gravimetric method.A umidade volumétrica do solo (teta no campo pode ser avaliada por métodos diretos e indiretos. Dentre os métodos diretos, o gravimétrico é considerado altamente confiável e, conseq

  14. Experimental estimation of regional lung water volume by histogram of pulmonary CT numbers

    International Nuclear Information System (INIS)

    Kato, Shiro; Momoki, Shigeru; Asai, Toshihiko; Shimada, Takeshi; Tamano, Masahiro; Nakamoto, Takaaki; Yoshimura, Masaharu

    1989-01-01

    Both in vitro and in vivo experiments were made to assess the ability of pulmonary CT numbers to quantitatively determine regional water volume in cases of pulmonary congestion or edema associated with left heart failure. In vitro experiment revealed a good linear correlation between the volume of injected water and the determined CT number of polyethylene tube packed with sponge. In the subsequent in vivo experiment with 10 adult mongrel dogs, lung water volumes obtained by pulmonary CT numbers were found to be consistent with the actual volumes. Pulmonary CT numbers for water volume proved to become parameters to quantitatively evaluate pulmonary congestion or edema. (Namekawa, K)

  15. A cache-friendly sampling strategy for texture-based volume rendering on GPU

    Directory of Open Access Journals (Sweden)

    Junpeng Wang

    2017-06-01

    Full Text Available The texture-based volume rendering is a memory-intensive algorithm. Its performance relies heavily on the performance of the texture cache. However, most existing texture-based volume rendering methods blindly map computational resources to texture memory and result in incoherent memory access patterns, causing low cache hit rates in certain cases. The distance between samples taken by threads of an atomic scheduling unit (e.g. a warp of 32 threads in CUDA of the GPU is a crucial factor that affects the texture cache performance. Based on this fact, we present a new sampling strategy, called Warp Marching, for the ray-casting algorithm of texture-based volume rendering. The effects of different sample organizations and different thread-pixel mappings in the ray-casting algorithm are thoroughly analyzed. Also, a pipeline manner color blending approach is introduced and the power of warp-level GPU operations is leveraged to improve the efficiency of parallel executions on the GPU. In addition, the rendering performance of the Warp Marching is view-independent, and it outperforms existing empty space skipping techniques in scenarios that need to render large dynamic volumes in a low resolution image. Through a series of micro-benchmarking and real-life data experiments, we rigorously analyze our sampling strategies and demonstrate significant performance enhancements over existing sampling methods.

  16. A device for fresh water sampling before radioactive measurements

    International Nuclear Information System (INIS)

    Maubert, Henri; Picat, Philippe.

    1982-06-01

    On account of the many field operations carried out by the laboratory, a water sampling device has been developed. This portable autonomous device performs in situ water filtration and concentration on ion exchange resins and activated carbon columns. The device is described and the trapping performance for 8 radionuclides is given. A comparison is made with the so-called evaporation method. The effects of the treatment of the filtrating elements on the radioactive results are studied. This sampling method is very sensitive [fr

  17. Tritium volume activity in natural waters of NPP Temelin region

    Energy Technology Data Exchange (ETDEWEB)

    Tomasek, M; Wilhelmova, L [Academy of Sciences of the Czech Rep., Prague (Czech Republic). Nuclear Physics Inst., Dept. of Radiation Dosimetry

    1996-12-31

    This paper presents the results of tritium measurement in selected rivers of NPP Temelin before its operation obtained during the period 1991-1994. Particular attention is paid to Vltava river into which liquid effluents will be discharged and which is also utilized as a drinking water supply for the capital Prague. Samples from the Vltava river were collected near the mouth of NPP waste canal (point Hladna)and in front of the intake into Prague water works (point Podoli). Tritium content was analysed also in surface waters of Paleckuv, Temelinsky and Strouha streams which can be affected by gaseous effluents due to atmospheric removal processes. Tritium activity was measured with Tric-Carb 1050 TR/LL liquid scintillation counter. The mean annual tritium activities of investigated river waters varied within 1.9-3.0 Bq/l during the period 1991-1994 and that their trend has been slowly decreasing. This fact, as well as seasonal variability, suggests, that tritium level in the surface waters of studied region is largely governed by this radionuclide global atmospheric fallout. The results of this work indicate the trend of background tritium in examined natural waters and make possible the evaluation of their potential future contamination. (J.K.) 1 tab., 2 figs., 4 refs.

  18. Gas-driven pump for ground-water samples

    Science.gov (United States)

    Signor, Donald C.

    1978-01-01

    Observation wells installed for artificial-recharge research and other wells used in different ground-water programs are frequently cased with small-diameter steel pipe. To obtain samples from these small-diameter wells in order to monitor water quality, and to calibrate solute-transport models, a small-diameter pump with unique operating characteristics is required that causes a minimum alternation of samples during field sampling. A small-diameter gas-driven pump was designed and built to obtain water samples from wells of two-inch diameter or larger. The pump is a double-piston type with the following characteristics: (1) The water sample is isolated from the operating gas, (2) no source of electricity is ncessary, (3) operation is continuous, (4) use of compressed gas is efficient, and (5) operation is reliable over extended periods of time. Principles of operation, actual operation techniques, gas-use analyses and operating experience are described. Complete working drawings and a component list are included. Recent modifications and pump construction for high-pressure applications also are described. (Woodard-USGS)

  19. UMTRA project water sampling and analysis plan, Durango, Colorado

    International Nuclear Information System (INIS)

    1994-01-01

    Surface remedial action has been completed at the Uranium Mill Tailings Remedial Action Project in Durango, Colorado. Contaminated soil and debris have been removed from the former processing site and placed in the Bodo Canyon disposal cell. Ground water at the former uranium mill/tailings site and raffinate pond area has been contaminated by the former milling operations. The ground water at the disposal site was not impacted by the former milling operations at the time of the cell's construction. Activities for fiscal 1994 involve ground water sampling and site characterization of the disposal site

  20. Water and steam sampling systems; Provtagningssystem foer vatten och aanga

    Energy Technology Data Exchange (ETDEWEB)

    Hellman, Mats

    2009-10-15

    The supervision of cycle chemistry can be divided into two parts, the sampling system and the chemical analysis. In modern steam generating plants most of the chemical analyses are carried out on-line. The detection limits of these analyzers are pushed downward to the ppt-range (parts per trillion), however the analyses are not more correct than the accuracy of the sampling system. A lot of attention has been put to the analyzers and the statistics to interpret the results but the sampling procedures has gained much less attention. This report aims to give guidance of the considerations to be made regarding sampling systems. Sampling is necessary since most analysis of interesting parameters cannot be carried out in- situ on-line in the steam cycle. Today's on-line instruments for pH, conductivity, silica etc. are designed to meet a water sample at a temperature of 10-30 deg C. This means that the sampling system has to extract a representative sample from the process, transport and cool it down to room temperature without changing the characteristics of the fluid. In the literature research work, standards and other reports can be found. Although giving similar recommendations in most aspects there are some discrepancies that may be confusing. This report covers all parts in the sampling system: Sample points and nozzles; Sample lines; Valves, regulating and on-off; Sample coolers; Temperature, pressure and flow rate control; Cooling water; and Water recovery. On-line analyzers connecting to the sampling system are not covered. This report aims to clarify what guidelines are most appropriate amongst the existing ones. The report should also give guidance to the design of the sampling system in order to achieve representative samples. In addition to this the report gives an overview of the fluid mechanics involved in sampling. The target group of this report is owners and operators of steam generators, vendors of power plant equipment, consultants working in

  1. Resource Conservation and Recovery Act ground-water monitoring projects for Hanford Facilities: Progress report for the period July 1 to September 30, 1989 - Volume 1 - Text

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.M.; Bates, D.J.; Lundgren, R.E.

    1989-12-01

    This is Volume 1 of a two-volume document that describes the progress of 14 Hanford Site ground-water monitoring projects for the period July 1 to September 30, 1989. This volume discusses the projects; Volume 2 provides as-built diagrams, completion/inspection reports, drilling logs, and geophysical logs for wells drilled, completed, or logged during this period. Volume 2 can be found on microfiche in the back pocket of Volume 1. The work described in this document is conducted by the Pacific Northwest Laboratory under the management of Westinghouse Hanford Company for the US Department of Energy. Concentrations of ground-water constituents are compared to federal drinking water standards throughout this document for reference purposes. All drinking water supplied from the sampled aquifer meets regulatory standards for drinking water quality.

  2. Preconcentration and determination of heavy metals in water, sediment and biological samples

    Directory of Open Access Journals (Sweden)

    Shirkhanloo Hamid

    2011-01-01

    Full Text Available In this study, a simple, sensitive and accurate column preconcentration method was developed for the determination of Cd, Cu and Pb ions in river water, urine and sediment samples by flame atomic absorption spectrometry. The procedure is based on the retention of the analytes on a mixed cellulose ester membrane (MCEM column from buffered sample solutions and then their elution from the column with nitric acid. Several parameters, such as pH of the sample solution, volume of the sample and eluent and flow rates of the sample were evaluated. The effects of diverse ions on the preconcentration were also investigated. The recoveries were >95 %. The developed method was applied to the determination of trace metal ions in river water, urine and sediment samples, with satisfactory results. The 3δ detection limits for Cu, Pb and Cd were found to be 2, 3 and 0.2 μg dm−3, respectively. The presented procedure was successfully applied for determination of the copper, lead and cadmium contents in real samples, i.e., river water and biological samples.

  3. Detection of protozoa in water samples by formalin/ether concentration method.

    Science.gov (United States)

    Lora-Suarez, Fabiana; Rivera, Raul; Triviño-Valencia, Jessica; Gomez-Marin, Jorge E

    2016-09-01

    Methods to detect protozoa in water samples are expensive and laborious. We evaluated the formalin/ether concentration method to detect Giardia sp., Cryptosporidium sp. and Toxoplasma in water. In order to test the properties of the method, we spiked water samples with different amounts of each protozoa (0, 10 and 50 cysts or oocysts) in a volume of 10 L of water. Immunofluorescence assay was used for detection of Giardia and Cryptosporidium. Toxoplasma oocysts were identified by morphology. The mean percent of recovery in 10 repetitions of the entire method, in 10 samples spiked with ten parasites and read by three different observers, were for Cryptosporidium 71.3 ± 12, for Giardia 63 ± 10 and for Toxoplasma 91.6 ± 9 and the relative standard deviation of the method was of 17.5, 17.2 and 9.8, respectively. Intraobserver variation as measured by intraclass correlation coefficient, was fair for Toxoplasma, moderate for Cryptosporidium and almost perfect for Giardia. The method was then applied in 77 samples of raw and drinkable water in three different plant of water treatment. Cryptosporidium was found in 28 of 77 samples (36%) and Giardia in 31 of 77 samples (40%). Theses results identified significant differences in treatment process to reduce the presence of Giardia and Cryptosporidium. In conclusion, the formalin ether method to concentrate protozoa in water is a new alternative for low resources countries, where is urgently need to monitor and follow the presence of theses protozoa in drinkable water. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Genotoxicity assessment of water sampled from R-11 reservoir by means of allium test

    Energy Technology Data Exchange (ETDEWEB)

    Bukatich, E.; Pryakhin, E. [Urals Research Center for Radiation Medicine (Russian Federation); Geraskin, S. [Russian Institute of Agricultural Radiology and Agroecology (Russian Federation)

    2014-07-01

    The Mayak PA was the first enterprise for the production of weapon-grade plutonium in Russia and it incorporates uranium-graphite reactors for plutonium production and radiochemical facilities for its separation. Radiochemical processing resulted in huge volumes of liquid radioactive wastes of different specific activities. To reduce the radionuclides release into the environment, a system of bypasses and ponds (the Techa Cascade Reservoirs system) to store low-activity liquid wastes has been constructed in the upper reaches of the Techa River. Currently, industrial reservoirs of Mayak PA contain over 350 million m{sup 3} of low-level radioactive liquid wastes with total activity over 7.4 x 10{sup 15} Bq. Reservoir R-11 is the final reservoir in the Techa Cascade Reservoirs system. The average specific activity of main radionuclides in the water of R-11 are: {sup 90}Sr - 1.4x10{sup 3} Bq/l; {sup 137}Cs - 3 Bq/l; {sup 3}H - 7x10{sup 2} Bq/l; α-emitting radionuclides - 2.6 x 10{sup -1} Bq/l. In our study the Allium-test was employed to estimate reservoir R-11 water genotoxic effects. In 2012, 3 water samples were collected in different parts of reservoir R-11. Water samples from the Shershnevskoye reservoir (artificial reservoir on the Miass River designed for Chelyabinsk city water supply) were used as natural control. Samples of distilled and bottled water were used as an additional laboratory control. The common onion, Allium cepa L. (Stuttgarter Riesen) was used. Healthy equal-sized bulbs were soaked for 24 hours at +4±2 deg. C to synchronize cell division. The bulbs were maintained in distilled water at +23 deg. C until roots have grown up to 2±1 mm length and then plunged into water samples. Control samples remained in distilled and bottled water as well as in water samples from the Shershnevskoye reservoir (natural control). Roots of the 18±3 mm length were randomly sampled and fixed in an alcohol/acetic acid mixture. For microscopic analysis, squashed

  5. Sampling art for ground-water monitoring wells in nuclide migration

    International Nuclear Information System (INIS)

    Liu Wenyuan; Tu Guorong; Dang Haijun; Wang Xuhui; Ke Changfeng

    2010-01-01

    Ground-Water sampling is one of the key parts in field nuclide migration. The objective of ground-water sampling program is to obtain samples that are representative of formation-quality water. In this paper, the ground-water sampling standards and the developments of sampling devices are reviewed. We also designed the sampling study projects which include the sampling methods, sampling parameters and the elementary devise of two types of ground-Water sampling devices. (authors)

  6. An experimental study on the excitation of large volume airguns in a small volume body of water

    International Nuclear Information System (INIS)

    Wang, Baoshan; Yang, Wei; Yuan, Songyong; Ge, Hongkui; Chen, Yong; Guo, Shijun; Xu, Ping

    2010-01-01

    A large volume airgun array is effective in generating seismic waves, which is extensively used in large volume bodies of water such as oceans, lakes and reservoirs. So far, the application of large volume airguns is subject to the distribution of large volume bodies of water. This paper reports an attempt to utilize large volume airguns in a small body of water as a seismic source for seismotectonic studies. We carried out a field experiment in Mapaoquan pond, Fangshan district, Beijing, during the period 25–30 May 2009. Bolt LL1500 airguns, each with volumes of 2000 in 3 , the largest commercial airguns available today, were used in this experiment. We tested the excitation of the airgun array with one or two guns. The airgun array was placed 7–11 m below the water's surface. The near- and far-field seismic motions induced by the airgun source were recorded by a 100 km long seismic profile composed of 16 portable seismometers and a 100 m long strong motion seismograph profile, respectively. The following conclusions can be drawn from this experiment. First, it is feasible to excite large volume airguns in a small volume body of water. Second, seismic signals from a single shot of one airgun can be recognized at the offset up to 15 km. Taking advantage of high source repeatability, we stacked records from 128 shots to enhance the signal-to-noise ratio, and direct P-waves can be easily identified at the offset ∼50 km in stacked records. Third, no detectable damage to fish or near-field constructions was caused by the airgun shots. Those results suggest that large volume airguns excited in small bodies of water can be used as a routinely operated seismic source for mid-scale (tens of kilometres) subsurface explorations and monitoring under various running conditions

  7. Water resources data for Virginia, water year 1991. Volume 2. Ground-water-level and ground-water-quality records. Water-data report (Annual), 1 October 1991-30 September 1992

    International Nuclear Information System (INIS)

    Prugh, B.J.; Powell, E.D.

    1993-01-01

    Water-resources data for the 1992 water year for Virginia consist of records of water levels and water quality of ground-water wells. The report (Volume 2. Ground-Water-Level and Ground-Water-Quality Records) contains water levels at 356 observation wells and water quality at 2 wells. Locations of these wells are given in the report

  8. UMTRA ground water sampling techniques: Comparison of the traditional and low flow methods

    International Nuclear Information System (INIS)

    1995-07-01

    This report describes the potential changes in water quality data that may occur with the conversion from MBV (multiple bore volume) to LF (low flow) sampling and provides two examples of how such a change might impact Project decisions. The existing scientific literature on LF sampling is reviewed and the new LF data from three UMTRA Uranium Mill Tailings Remedial Action Project sites are evaluated seeking answers to the questions posed above. Several possible approaches, that the UMTRA Project may take to address issues unanswered by the literature are presented and compared, and a recommendation is offered for the future direction of the LF conversion effort

  9. Filtration recovery of extracellular DNA from environmental water samples

    Science.gov (United States)

    qPCR methods are able to analyze DNA from microbes within hours of collecting water samples, providing the promptest notification and public awareness possible when unsafe pathogenic levels are reached. Health risk, however, may be overestimated by the presence of extracellular ...

  10. Determination of thiobencarb in water samples by gas ...

    African Journals Online (AJOL)

    Homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA) coupled with gas chromatography-flame ionization detection (GC-FID) was applied for the extraction and determination of thiobencarb in water samples. In this study, a special extraction cell was designed to facilitate collection of the ...

  11. Determination of lead at nanogram level in water samples by ...

    African Journals Online (AJOL)

    A novel method of chemistry applicable to the determination of trace lead in water samples based on the resonance light scattering (RLS) technique has been developed. In dilute phosphoric acid medium, in the presence of a large excess of I-, Pb(II) can form [PbI4]2-, which further reacts with tetrabutyl ammonium bromide ...

  12. preconcentration of uranium in water samples using dispersive

    African Journals Online (AJOL)

    B. S. Chandravanshi

    Atomic Energy Organization of Iran, P.O. Box 14395-836, Tehran, Iran. 2Department of ... A new liquid phase microextraction method based on the dispersion of an extraction solvent into aqueous phase ... optical emission spectrometry, Uranium, Water samples ..... The validation of the presented procedure was performed ...

  13. In situ sampling of interstitial water from lake sediments

    NARCIS (Netherlands)

    Brinkman, Albertus G.; van Raaphorst, Wim; Lijklema, Lambertus

    1982-01-01

    A sampler with a relatively high resolution has been developed, which allows interstitial water to be obtained from lake sediments at well defined depths, without serious disturbance of sediment structure. Oxidation effects are excluded. Sampling time is in the order of a day. Installation requires

  14. Ground-water sample collection and analysis plan for the ground-water surveillance project

    International Nuclear Information System (INIS)

    Bryce, R.W.; Evans, J.C.; Olsen, K.B.

    1991-12-01

    The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy's (DOE's) Hanford Site in support of DOE's environmental surveillance responsibilities. The purpose of this document is to translate DOE's General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives

  15. A Curriculum Activities Guide to Water Pollution and Environmental Studies, Volume II - Appendices.

    Science.gov (United States)

    Hershey, John T., Ed.; And Others

    This publication, Volume II of a two volume set of water pollution studies, contains seven appendices which support the studies. Appendix 1, Water Quality Parameters, consolidates the technical aspects of water quality including chemical, biological, computer program, and equipment information. Appendix 2, Implementation, outlines techniques…

  16. Algae viability over time in a ballast water sample

    Science.gov (United States)

    Gollasch, Stephan; David, Matej

    2018-03-01

    The biology of vessels' ballast water needs to be analysed for several reasons, one of these being performance tests of ballast water management systems. This analysis includes a viability assessment of phytoplankton. To overcome logistical problems to get algae sample processing gear on board of a vessel to document algae viability, samples may be transported to land-based laboratories. Concerns were raised how the storage conditions of the sample may impact algae viability over time and what the most appropriate storage conditions were. Here we answer these questions with a long-term algae viability study with daily sample analysis using Pulse-Amplitude Modulated (PAM) fluorometry. The sample was analysed over 79 days. We tested different storage conditions: fridge and room temperature with and without light. It seems that during the first two weeks of the experiment the viability remains almost unchanged with a slight downwards trend. In the continuing period, before the sample was split, a slightly stronger downwards viability trend was observed, which occurred at a similar rate towards the end of the experiment. After the sample was split, the strongest viability reduction was measured for the sample stored without light at room temperature. We concluded that the storage conditions, especially regarding temperature and light exposure, have a stronger impact on algae viability compared to the storage duration and that inappropriate storage conditions reduce algal viability. A sample storage time of up to two weeks in a dark and cool environment has little influence on the organism viability. This indicates that a two week time duration between sample taking on board a vessel and the viability measurement in a land-based laboratory may not be very critical.

  17. Mapping, organic matter mass and water volume of a peatland in Serra do Espinhaço Meridional

    Directory of Open Access Journals (Sweden)

    José Ricardo da Rocha Campos

    2012-06-01

    Full Text Available Peatlands form in areas where net primary of organic matter production exceeds losses due to the decomposition, leaching or disturbance. Due to their chemical and physical characteristics, bogs can influence water dynamics because they can store large volumes of water in the rainy season and gradually release this water during the other months of the year. In Diamantina, Minas Gerais, Brazil, a peatland in the environmental protection area of Pau-de-Fruta ensures the water supply of 40,000 inhabitants. The hypothesis of this study is that the peat bogs in Pau-de-Fruta act as an environment for carbon storage and a regulator of water flow in the Córrego das Pedras basin. The objective of this study was to estimate the water volume and organic matter mass in this peatland and to study the influence of this environment on the water flow in the Córrego das Pedras basin. The peatland was mapped using 57 transects, at intervals of 100 m. Along all transects, the depth of the peat bog, the Universal Transverse Mercator (UTM coordinates and altitude were recorded every 20 m and used to calculate the area and volume of the peatland. The water volume was estimated, using a method developed in this study, and the mass of organic matter based on samples from 106 profiles. The peatland covered 81.7 hectares (ha, and stored 497,767 m³ of water, representing 83.7 % of the total volume of the peat bog. The total amount of organic matter (OM was 45,148 t, corresponding to 552 t ha-1 of OM. The peat bog occupies 11.9 % of the area covered by the Córrego das Pedras basin and stores 77.6 % of the annual water surplus, thus controlling the water flow in the basin and consequently regulating the water course.

  18. An Optimized Method for Quantification of Pathogenic Leptospira in Environmental Water Samples.

    Science.gov (United States)

    Riediger, Irina N; Hoffmaster, Alex R; Casanovas-Massana, Arnau; Biondo, Alexander W; Ko, Albert I; Stoddard, Robyn A

    2016-01-01

    Leptospirosis is a zoonotic disease usually acquired by contact with water contaminated with urine of infected animals. However, few molecular methods have been used to monitor or quantify pathogenic Leptospira in environmental water samples. Here we optimized a DNA extraction method for the quantification of leptospires using a previously described Taqman-based qPCR method targeting lipL32, a gene unique to and highly conserved in pathogenic Leptospira. QIAamp DNA mini, MO BIO PowerWater DNA and PowerSoil DNA Isolation kits were evaluated to extract DNA from sewage, pond, river and ultrapure water samples spiked with leptospires. Performance of each kit varied with sample type. Sample processing methods were further evaluated and optimized using the PowerSoil DNA kit due to its performance on turbid water samples and reproducibility. Centrifugation speeds, water volumes and use of Escherichia coli as a carrier were compared to improve DNA recovery. All matrices showed a strong linearity in a range of concentrations from 106 to 10° leptospires/mL and lower limits of detection ranging from Leptospira in environmental waters (river, pond and sewage) which consists of the concentration of 40 mL samples by centrifugation at 15,000×g for 20 minutes at 4°C, followed by DNA extraction with the PowerSoil DNA Isolation kit. Although the method described herein needs to be validated in environmental studies, it potentially provides the opportunity for effective, timely and sensitive assessment of environmental leptospiral burden.

  19. Amplification volume reduction on DNA database samples using FTA™ Classic Cards.

    Science.gov (United States)

    Wong, Hang Yee; Lim, Eng Seng Simon; Tan-Siew, Wai Fun

    2012-03-01

    The DNA forensic community always strives towards improvements in aspects such as sensitivity, robustness, and efficacy balanced with cost efficiency. Therefore our laboratory decided to study the feasibility of PCR amplification volume reduction using DNA entrapped in FTA™ Classic Card and to bring cost savings to the laboratory. There were a few concerns the laboratory needed to address. First, the kinetics of the amplification reaction could be significantly altered. Second, an increase in sensitivity might affect interpretation due to increased stochastic effects even though they were pristine samples. Third, statics might cause FTA punches to jump out of its allocated well into another thus causing sample-to-sample contamination. Fourth, the size of the punches might be too small for visual inspection. Last, there would be a limit to the extent of volume reduction due to evaporation and the possible need of re-injection of samples for capillary electrophoresis. The laboratory had successfully optimized a reduced amplification volume of 10 μL for FTA samples. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  20. Gamut Volume Index: a color preference metric based on meta-analysis and optimized colour samples.

    Science.gov (United States)

    Liu, Qiang; Huang, Zheng; Xiao, Kaida; Pointer, Michael R; Westland, Stephen; Luo, M Ronnier

    2017-07-10

    A novel metric named Gamut Volume Index (GVI) is proposed for evaluating the colour preference of lighting. This metric is based on the absolute gamut volume of optimized colour samples. The optimal colour set of the proposed metric was obtained by optimizing the weighted average correlation between the metric predictions and the subjective ratings for 8 psychophysical studies. The performance of 20 typical colour metrics was also investigated, which included colour difference based metrics, gamut based metrics, memory based metrics as well as combined metrics. It was found that the proposed GVI outperformed the existing counterparts, especially for the conditions where correlated colour temperatures differed.

  1. Collection and preparation of water samples for hydrogeochemical reconnaissance

    International Nuclear Information System (INIS)

    Baucom, E.I.; Ferguson, R.B.; Wallace, R.M.

    1977-01-01

    A method based on ion exchange and neutron activation analysis (NAA) was developed and field-tested to determine uranium over the range 0.02 to 10,000 ppb in natural water using a single procedure. Water samples are filtered in the field using a specially-designed one-liter filter apparatus pressurized to 40 psig with an inert gas. The filtered water is treated with a high purity, mixed cation-anion resin in the hydronium-hydroxide form. All ions are removed from solution under the strong driving force of the neutralization reaction. Anionic, cationic, and natural complexes of uranium can be concentrated with this method. Field tests showed greater than 95 percent recovery of 13 elements analyzed (including greater than 99 percent recovery of uranium) and greater than or equal to 90 percent recovery of 4 other elements. Uranium collected on the resin was quantitatively determined by NAA. Coefficient of variation for sampling plus analysis was less than 20 percent for samples containing more than 0.1 ppb uranium. Advantages of this method include: (1) wide dynamic range, (2) low detection limit for uranium (0.02 ppb), (3) high precision and accuracy, (4) relatively low cost, (5) high-yield recovery from low-level aqueous samples without risk of loss to containers, (6) decreased risk of significant sample contamination compared with other low-level methods, (7) production of stable samples suitable for retrievable storage, and(8) concentration of other ions that can be determined by NAA. This paper presents (1) background regarding development of procedures for sample collection and preparation, (2) results of development programs, (3) description of equipment and field procedures, and (4) preliminary conclusions regarding use of this technology for hydrogeochemical reconnaissance for uranium

  2. Sampling procedures for inventory of commercial volume tree species in Amazon Forest.

    Science.gov (United States)

    Netto, Sylvio P; Pelissari, Allan L; Cysneiros, Vinicius C; Bonazza, Marcelo; Sanquetta, Carlos R

    2017-01-01

    The spatial distribution of tropical tree species can affect the consistency of the estimators in commercial forest inventories, therefore, appropriate sampling procedures are required to survey species with different spatial patterns in the Amazon Forest. For this, the present study aims to evaluate the conventional sampling procedures and introduce the adaptive cluster sampling for volumetric inventories of Amazonian tree species, considering the hypotheses that the density, the spatial distribution and the zero-plots affect the consistency of the estimators, and that the adaptive cluster sampling allows to obtain more accurate volumetric estimation. We use data from a census carried out in Jamari National Forest, Brazil, where trees with diameters equal to or higher than 40 cm were measured in 1,355 plots. Species with different spatial patterns were selected and sampled with simple random sampling, systematic sampling, linear cluster sampling and adaptive cluster sampling, whereby the accuracy of the volumetric estimation and presence of zero-plots were evaluated. The sampling procedures applied to species were affected by the low density of trees and the large number of zero-plots, wherein the adaptive clusters allowed concentrating the sampling effort in plots with trees and, thus, agglutinating more representative samples to estimate the commercial volume.

  3. Infrared thermometry and the crop water stress index. II. Sampling procedures and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, B. R. [BP Research, Cleveland, OH (United States); Nielsen, D. C.; Shock, C. C.

    1992-10-15

    Infrared thermometry can be a valuable research and production tool for detecting and quantifying water stress in plants, as shown by a large volume of published research. Users of infrared thermometers (IRT) should be aware of the many equipment, environmental, and plant factors influencing canopy temperature measured by an IRT. The purpose of this paper is to describe factors influencing measured plant temperature, outline sampling procedures that will produce reliable Crop Water Stress Index (CWSI) values, and offer interpretations of CWSI and plant temperatures relative to crop production and other water stress parameters by reviewing previously conducted research. Factors that are considered are IRT condition, configuration, and position; psychrometer location; wind speed; solar radiation; time of day; leaf area and orientation; and appropriate non-water-stressed baseline equation. Standard sampling and CWSI calculation procedures are proposed. Use of CWSI with crops varying in type of response to water stress is described. Previously conducted research on plant temperatures or CWSI is tabulated by crop and water stress parameters measured. The paper provides valuable information to assist interested users of IRTs in making reliable water stress measurements. (author)

  4. Infrared thermometry and the crop water stress index. II. Sampling procedures and interpretation

    International Nuclear Information System (INIS)

    Gardner, B.R.; Nielsen, D.C.; Shock, C.C.

    1992-01-01

    Infrared thermometry can be a valuable research and production tool for detecting and quantifying water stress in plants, as shown by a large volume of published research. Users of infrared thermometers (IRT) should be aware of the many equipment, environmental, and plant factors influencing canopy temperature measured by an IRT. The purpose of this paper is to describe factors influencing measured plant temperature, outline sampling procedures that will produce reliable Crop Water Stress Index (CWSI) values, and offer interpretations of CWSI and plant temperatures relative to crop production and other water stress parameters by reviewing previously conducted research. Factors that are considered are IRT condition, configuration, and position; psychrometer location; wind speed; solar radiation; time of day; leaf area and orientation; and appropriate non-water-stressed baseline equation. Standard sampling and CWSI calculation procedures are proposed. Use of CWSI with crops varying in type of response to water stress is described. Previously conducted research on plant temperatures or CWSI is tabulated by crop and water stress parameters measured. The paper provides valuable information to assist interested users of IRTs in making reliable water stress measurements. (author)

  5. Determination of Cs-134 and Cs-137 rain water samples

    International Nuclear Information System (INIS)

    Lima, M.F.; Mazzilli, B.

    1988-01-01

    In order to setting an environmental monitoring program at IPEN, was developed a fast and simple methodology for concentration of Cs-134 and Cs-137 in rain water. This procedure consists in the precipitation of cesium and others cathions of its family (NH 4 + , K + and Rb + ) by ammonium molybdophosphate. The measures of the desintegration rates of Cs-134 and Cs-137 was done by gamma spectrometry in a Ge(Li) detector. After setting up the ideal experimental conditions, the procedure was used to analyze four samples of rain water. (author) [pt

  6. Hexagonal ice in pure water and biological NMR samples

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Thomas; Gath, Julia; Hunkeler, Andreas; Ernst, Matthias, E-mail: maer@ethz.ch [ETH Zurich, Physical Chemistry (Switzerland); Böckmann, Anja, E-mail: a.bockmann@ibcp.fr [UMR 5086 CNRS, Université de Lyon 1, Institut de Biologie et Chimie des Protéines (France); Meier, Beat H., E-mail: beme@ethz.ch [ETH Zurich, Physical Chemistry (Switzerland)

    2017-01-15

    Ice, in addition to “liquid” water and protein, is an important component of protein samples for NMR spectroscopy at subfreezing temperatures but it has rarely been observed spectroscopically in this context. We characterize its spectroscopic behavior in the temperature range from 100 to 273 K, and find that it behaves like pure water ice. The interference of magic-angle spinning (MAS) as well as rf multiple-pulse sequences with Bjerrum-defect motion greatly influences the ice spectra.

  7. Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, Lorena [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Domini, Claudia E. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Grane, Nuria [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Psillakis, Elefteria [Department of Environmental Engineering, Technical University of Crete, Polytechneioupolis, GR-73100 Chania, Crete (Greece); Canals, Antonio [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain)]. E-mail: a.canals@ua.es

    2007-05-29

    A one-step and in-situ sample preparation method used for quantifying chlorobenzene compounds in water samples has been developed, coupling microwave and headspace single-drop microextraction (MW-HS-SDME). The chlorobenzenes in water samples were extracted directly onto an ionic liquid single-drop in headspace mode under the aid of microwave radiation. For optimization, a Plackett-Burman screening design was initially used, followed by a mixed-level factorial design. The factors considered were: drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time, ionic liquid type, microwave power and length of the Y-shaped glass-tube. The optimum experimental conditions found from this statistical evaluation were: a 5 {mu}L microdrop of 1-hexyl-3-methylimidazolium hexafluorophosphate exposed for 20 min to the headspace of a 30 mL aqueous sample, irradiated by microwaves at 200 W and placed in a 50 mL spherical flask connected to a 25 cm Y-shaped glass-tube. Under the optimised experimental conditions, the response of a high performance liquid chromatographic system was found to be linear over the range studied and with correlation coefficients ranging between 0.9995 and 0.9999. The method showed a good level of repeatability, with relative standard deviations varying between 2.3 and 8.3% (n = 5). Detection limits were found in the low {mu}g L{sup -1} range varying between 0.016 and 0.039 {mu}g L{sup -1}. Overall, the performance of the proposed method demonstrated the favourable effect of microwave sample irradiation upon HS-SDME. Finally, recovery studies from different types of environmental water samples revealed that matrix had little effect upon extraction.

  8. Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples

    International Nuclear Information System (INIS)

    Vidal, Lorena; Domini, Claudia E.; Grane, Nuria; Psillakis, Elefteria; Canals, Antonio

    2007-01-01

    A one-step and in-situ sample preparation method used for quantifying chlorobenzene compounds in water samples has been developed, coupling microwave and headspace single-drop microextraction (MW-HS-SDME). The chlorobenzenes in water samples were extracted directly onto an ionic liquid single-drop in headspace mode under the aid of microwave radiation. For optimization, a Plackett-Burman screening design was initially used, followed by a mixed-level factorial design. The factors considered were: drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time, ionic liquid type, microwave power and length of the Y-shaped glass-tube. The optimum experimental conditions found from this statistical evaluation were: a 5 μL microdrop of 1-hexyl-3-methylimidazolium hexafluorophosphate exposed for 20 min to the headspace of a 30 mL aqueous sample, irradiated by microwaves at 200 W and placed in a 50 mL spherical flask connected to a 25 cm Y-shaped glass-tube. Under the optimised experimental conditions, the response of a high performance liquid chromatographic system was found to be linear over the range studied and with correlation coefficients ranging between 0.9995 and 0.9999. The method showed a good level of repeatability, with relative standard deviations varying between 2.3 and 8.3% (n = 5). Detection limits were found in the low μg L -1 range varying between 0.016 and 0.039 μg L -1 . Overall, the performance of the proposed method demonstrated the favourable effect of microwave sample irradiation upon HS-SDME. Finally, recovery studies from different types of environmental water samples revealed that matrix had little effect upon extraction

  9. Water volume reduction increases eutrophication risk in tropical semi-arid reservoirs

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Nascimento da Rocha Junior

    2018-04-01

    Full Text Available Abstract Aim Global patterns of temperature and precipitation have significantly changed over the last century and nearly all predictions point to even greater changes by the end of 2100. Long periods of drought in semi-arid regions generally reduce reservoirs and lakes water level, increasing the nutrients concentrations in the water. Our principal hypothesis is that water volume reduction, driven by prolonged droughts, will increase reservoirs susceptibility to eutrophication and accordingly an increase in trophic state. To test this hypothesis, we used a comparative analysis of ecosystems in a space-for-time substitution approach, in a Brazilian semi-arid region, to predict the consequences of reservoirs water volume reduction on key limnological variables. Methods We sampled 16 reservoirs located in two sub-basins with contrasting rainfall regimes, inserted on Piranhas-Açu watershed. The Seridó River basin (SB is dry and the Piancó River basin (SB is humid, with annual mean precipitation of 500 and 700 mm, respectively. Linear regressions analyzes were performed to assess whether the percentage of maximum volume stored (%MVS is a good predictor for total phosphorus (TP, total nitrogen (TN and chlorophyll-a (CHLA. In addition, a two factorial analysis of variance (two-way ANOVA was performed to test for period (dry, very dry and extremely dry, basin (SB and PB and their interactions effects on TP, TN, CHLA, conductivity, turbidity, and Secchi depth. Results The results showed a reduction in the reservoirs %MVS both for PB and SB regions. At the extremely dry period, all reservoirs were classified as eutrophic, but TP concentrations reached much higher values in SB than in PB. The linear regressions analyses showed that the TP and TN were negatively related to %MVS during all periods sampled. The two-way ANOVA showed that there were significant basin and period effects on TP, TN, Secchi depth and turbidity, whereas for CHLA and conductivity

  10. A self-sampling method to obtain large volumes of undiluted cervicovaginal secretions.

    Science.gov (United States)

    Boskey, Elizabeth R; Moench, Thomas R; Hees, Paul S; Cone, Richard A

    2003-02-01

    Studies of vaginal physiology and pathophysiology sometime require larger volumes of undiluted cervicovaginal secretions than can be obtained by current methods. A convenient method for self-sampling these secretions outside a clinical setting can facilitate such studies of reproductive health. The goal was to develop a vaginal self-sampling method for collecting large volumes of undiluted cervicovaginal secretions. A menstrual collection device (the Instead cup) was inserted briefly into the vagina to collect secretions that were then retrieved from the cup by centrifugation in a 50-ml conical tube. All 16 women asked to perform this procedure found it feasible and acceptable. Among 27 samples, an average of 0.5 g of secretions (range, 0.1-1.5 g) was collected. This is a rapid and convenient self-sampling method for obtaining relatively large volumes of undiluted cervicovaginal secretions. It should prove suitable for a wide range of assays, including those involving sexually transmitted diseases, microbicides, vaginal physiology, immunology, and pathophysiology.

  11. Known volume air sampling pump. Final summary report Jun 1975--Nov 1976

    International Nuclear Information System (INIS)

    McCullough, J.E.; Peterson, A.

    1976-11-01

    The purpose of this development program was to design and develop a known volume air sampling pump for use in measuring the amount of radioactive material in the atmosphere of an underground uranium mine. The principal nuclear radiation hazard to underground uranium mines comes from the mine atmosphere. Daughter products of radon-222 are inhaled by the miner resulting in a relatively high lung cancer rate among these workers. Current exposure control practice employs spot sampling in working areas to measure working level values. Currently available personal air sampling pumps fail to deliver known volumes of air under widely changing differential pressures. A unique type of gas pump known as the scroll compressor, developed by Arthur D. Little, Inc., that has no values and few moving parts is expected to provide a practical, efficient, and dependable air pump for use in dosimeters. The three deliverable known volume air sampling pumps resulting from this work incorporate a scroll pump, drive motor, speed control electronics, and battery pack in a container suitable for attachment to a miner's belt

  12. Effect of NaOH on large-volume sample stacking of haloacetic acids in capillary zone electrophoresis with a low-pH buffer.

    Science.gov (United States)

    Tu, Chuanhong; Zhu, Lingyan; Ang, Chay Hoon; Lee, Hian Kee

    2003-06-01

    Large-volume sample stacking (LVSS) is an effective on-capillary sample concentration method in capillary zone electrophoresis, which can be applied to the sample in a low-conductivity matrix. NaOH solution is commonly used to back-extract acidic compounds from organic solvent in sample pretreatment. The effect of NaOH as sample matrix on LVSS of haloacetic acids was investigated in this study. It was found that the presence of NaOH in sample did not compromise, but rather help the sample stacking performance if a low pH background electrolyte (BGE) was used. The sensitivity enhancement factor was higher than the case when sample was dissolved in pure water or diluted BGE. Compared with conventional injection (0.4% capillary volume), 97-120-fold sensitivity enhancement in terms of peak height was obtained without deterioration of separation with an injection amount equal to 20% of the capillary volume. This method was applied to determine haloacetic acids in tap water by combination with liquid-liquid extraction and back-extraction into NaOH solution. Limits of detection at sub-ppb levels were obtained for real samples with direct UV detection.

  13. Monolith Chromatography as Sample Preparation Step in Virome Studies of Water Samples.

    Science.gov (United States)

    Gutiérrez-Aguirre, Ion; Kutnjak, Denis; Rački, Nejc; Rupar, Matevž; Ravnikar, Maja

    2018-01-01

    Viruses exist in aquatic media and many of them use this media as transmission route. Next-generation sequencing (NGS) technologies have opened new doors in virus research, allowing also to reveal a hidden diversity of viral species in aquatic environments. Not surprisingly, many of the newly discovered viruses are found in environmental fresh and marine waters. One of the problems in virome research can be the low amount of viral nucleic acids present in the sample in contrast to the background ones (host, eukaryotic, prokaryotic, environmental). Therefore, virus enrichment prior to NGS is necessary in many cases. In water samples, an added problem resides in the low concentration of viruses typically present in aquatic media. Different concentration strategies have been used to overcome such limitations. CIM monoliths are a new generation of chromatographic supports that due to their particular structural characteristics are very efficient in concentration and purification of viruses. In this chapter, we describe the use of CIM monolithic chromatography for sample preparation step in NGS studies targeting viruses in fresh or marine water. The step-by-step protocol will include a case study where CIM concentration was used to study the virome of a wastewater sample using NGS.

  14. Fluoroquinolone antibiotics in environmental waters: sample preparation and determination.

    Science.gov (United States)

    Speltini, Andrea; Sturini, Michela; Maraschi, Federica; Profumo, Antonella

    2010-04-01

    The aim of this review is to provide a general overview on the analytical methods proposed in the last decade for trace fluoroquinolone (FQ) determination in environmental waters. A large number of studies have been developed on this topic in reason of the importance of their monitoring in the studies of environmental mobility and potential degradation pathways. Every step of the analysis has been carefully considered, with a particular attention to sample preparation, in relationship with the problems involved in the analysis of real matrices. The different strategies to minimise interference from organic matter and to achieve optimal sensitivity, especially important in those samples with lower FQ concentrations, were also highlighted. Results and progress in this field have been described and critically commented. Moreover, a worldwide overview on the presence of FQs in the environmental waters has been reported.

  15. Examining the effect of psychopathic traits on gray matter volume in a community substance abuse sample.

    Science.gov (United States)

    Cope, Lora M; Shane, Matthew S; Segall, Judith M; Nyalakanti, Prashanth K; Stevens, Michael C; Pearlson, Godfrey D; Calhoun, Vince D; Kiehl, Kent A

    2012-11-30

    Psychopathy is believed to be associated with brain abnormalities in both paralimbic (i.e., orbitofrontal cortex, insula, temporal pole, parahippocampal gyrus, posterior cingulate) and limbic (i.e., amygdala, hippocampus, anterior cingulate) regions. Recent structural imaging studies in both community and prison samples are beginning to support this view. Sixty-six participants, recruited from community corrections centers, were administered the Hare psychopathy checklist-revised (PCL-R), and underwent magnetic resonance imaging (MRI). Voxel-based morphometry was used to test the hypothesis that psychopathic traits would be associated with gray matter reductions in limbic and paralimbic regions. Effects of lifetime drug and alcohol use on gray matter volume were covaried. Psychopathic traits were negatively associated with gray matter volumes in right insula and right hippocampus. Additionally, psychopathic traits were positively associated with gray matter volumes in bilateral orbital frontal cortex and right anterior cingulate. Exploratory regression analyses indicated that gray matter volumes within right hippocampus and left orbital frontal cortex combined to explain 21.8% of the variance in psychopathy scores. These results support the notion that psychopathic traits are associated with abnormal limbic and paralimbic gray matter volume. Furthermore, gray matter increases in areas shown to be functionally impaired suggest that the structure-function relationship may be more nuanced than previously thought. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. An opacity-sampled treatment of water vapor

    Science.gov (United States)

    Alexander, David R.; Augason, Gordon C.; Johnson, Hollis R.

    1989-01-01

    Although the bands of H2O are strong in the spectra of cool stars and calculations have repeatedly demonstrated their significance as opacity sources, only approximate opacities are currently available, due both to the difficulty of accounting for the millions of lines involved and to the inadequacy of laboratory and theoretical data. To overcome these obstacles, a new treatment is presented, based upon a statistical representation of the water vapor spectrum derived from available laboratory data. This statistical spectrum of water vapor employs an exponential distribution of line strengths and random positions of lines whose overall properties are forced to reproduce the mean opacities observed in the laboratory. The resultant data set is then treated by the opacity-sampling method exactly as are all other lines, both molecular and atomic. Significant differences are found between the results of this improved treatment and the results obtained with previous treatments of water-vapor opacity.

  17. Pore water sampling in acid sulfate soils: a new peeper method.

    Science.gov (United States)

    Johnston, Scott G; Burton, Edward D; Keene, Annabelle F; Bush, Richard T; Sullivan, Leigh A; Isaacson, Lloyd

    2009-01-01

    This study describes the design, deployment, and application of a modified equilibration dialysis device (peeper) optimized for sampling pore waters in acid sulfate soils (ASS). The modified design overcomes the limitations of traditional-style peepers, when sampling firm ASS materials over relatively large depth intervals. The new peeper device uses removable, individual cells of 25 mL volume housed in a 1.5 m long rigid, high-density polyethylene rod. The rigid housing structure allows the device to be inserted directly into relatively firm soils without requiring a supporting frame. The use of removable cells eliminates the need for a large glove-box after peeper retrieval, thus simplifying physical handling. Removable cells are easily maintained in an inert atmosphere during sample processing and the 25-mL sample volume is sufficient for undertaking multiple analyses. A field evaluation of equilibration times indicates that 32 to 38 d of deployment was necessary. Overall, the modified method is simple and effective and well suited to acquisition and processing of redox-sensitive pore water profiles>1 m deep in acid sulfate soil or any other firm wetland soils.

  18. Brachytherapy dose-volume histogram computations using optimized stratified sampling methods

    International Nuclear Information System (INIS)

    Karouzakis, K.; Lahanas, M.; Milickovic, N.; Giannouli, S.; Baltas, D.; Zamboglou, N.

    2002-01-01

    A stratified sampling method for the efficient repeated computation of dose-volume histograms (DVHs) in brachytherapy is presented as used for anatomy based brachytherapy optimization methods. The aim of the method is to reduce the number of sampling points required for the calculation of DVHs for the body and the PTV. From the DVHs are derived the quantities such as Conformity Index COIN and COIN integrals. This is achieved by using partial uniform distributed sampling points with a density in each region obtained from a survey of the gradients or the variance of the dose distribution in these regions. The shape of the sampling regions is adapted to the patient anatomy and the shape and size of the implant. For the application of this method a single preprocessing step is necessary which requires only a few seconds. Ten clinical implants were used to study the appropriate number of sampling points, given a required accuracy for quantities such as cumulative DVHs, COIN indices and COIN integrals. We found that DVHs of very large tissue volumes surrounding the PTV, and also COIN distributions, can be obtained using a factor of 5-10 times smaller the number of sampling points in comparison with uniform distributed points

  19. Evaluation of polyethersulfone performance for the microextraction of polar chlorinated herbicides from environmental water samples.

    Science.gov (United States)

    Prieto, Ailette; Rodil, Rosario; Quintana, José Benito; Cela, Rafael; Möder, Monika; Rodríguez, Isaac

    2014-05-01

    In this work, the suitability of bulk polyethersulfone (PES) for sorptive microextraction of eight polar, chlorinated phenoxy acids and dicamba from environmental water samples is assessed and the analytical features of the optimized method are compared to those reported for other microextraction techniques. Under optimized conditions, extractions were performed with samples (18 mL) adjusted at pH 2 and containing a 30% (w/v) of sodium chloride, using a tubular PES sorbent (1 cm length × 0.7 mm o.d., sorbent volume 8 µL). Equilibrium conditions were achieved after 3h of direct sampling, with absolute extraction efficiencies ranging from 39 to 66%, depending on the compound. Analytes were recovered soaking the polymer with 0.1 mL of ethyl acetate, derivatized and determined by gas chromatography-mass spectrometry (GC-MS). Achieved quantification limits (LOQs) varied between 0.005 and 0.073 ng mL(-1). After normalization with the internal surrogate (IS), the efficiency of the extraction was only moderately affected by the particular characteristics of different water samples (surface and sewage water); thus, pseudo-external calibration, using spiked ultrapure water solutions, can be used as quantification technique. The reduced cost of the PES polymer allowed considering it as a disposable sorbent, avoiding variations in the performance of the extraction due to cross-contamination problems and/or surface modification with usage. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. GROUND WATER SAMPLING OF VOCS IN THE WATER/CAPILLARY FRINGE AREA FOR VAPOR INTRUSION ASSESSMENT

    Science.gov (United States)

    Vapor intrusion has recently been considered a major pathway for increased indoor air contamination from certain volatile organic contaminants (VOCs). The recent Draft EPA Subsurface Vapor Intrusion Guidance Document states that ground water samples should be obtained from the u...

  1. Transportable aerosol sampling station with fixed volume (15 l) DMPA-15

    International Nuclear Information System (INIS)

    Giolu, G.; Guta, V.

    1999-01-01

    The mobile installation is used for air-sampling operations with fixed intake volumes, to be analysed by laboratories of routine environmental air monitoring. The station consists of several units, installed on a two-wheel mobile carriage-type platform: - a double - diaphragm pump (ensuring oil separation) that provides air intake and its evacuation to the air-analysers. The sampling and control unit has the following functions: - intake ensured by the pump that aspirates fixed volumes of air from the ambient atmosphere and feeding with it an inflatable rubber chamber. Air intake is automatically stopped as the cushion is filled up completely. A separation clamp is provided to seal up the cushion; - exhaust - allows the residual air to be evacuated from the cushion, ensuring its 'self-cleaning'; - shut down, manually operated; - analyse, the aerosol containing sample is aspirated from the inflatable rubber chamber and evacuated through a flow regulator to the analyser; - stop, canceling any previous commands. A relay unit controls the pneumatic lines and a pressure relay provides automatic stop of air intake process. The following technical features are given: - The fixed air volume in the chamber, 15 l - the air flow at the exit from the flow-meter, 0 - 15 l/min; - power requirements, 220 V/ 50 Hz; - power consumption, max. 1,5 kW; - overall dimensions, 460 x 500 x 820 mm; - weight, 53 kg. (authors)

  2. Extravascular lung water: its measurement by simultaneous pulmonary and aortic sampling and iterative convolution

    International Nuclear Information System (INIS)

    Giuntini, C.; Fazio, F.

    1975-01-01

    The inadequacy of the apparent distribution volume of THO during the first passage dilution curve (a) to account for the total lung water in in-vitro measurements in dogs and (b) to measure any increase in lung water, even in patients with obvious clinical pulmonary oedema, prompted the present investigation. Tritiated water, THO, as diffusible indicator, and human serum albumin labelled with 131 I, ALB, as intravascular tracer, are injected into the superior vena cava at the junction with the right atrium. In order to clear the aortic blood samples of recirculation, the recirculating tracers must be determined. This is accomplished by pulmonary artery sampling. Iterative convolution of the pulmonary artery dilution curves with suitable test functions eventually yields products of convolution that fit well the corresponding aortic dilution curves of THO and ALB. The test functions that yield the best fit are taken to represent the frequency functions of the transit time from pulmonary artery to aorta of THO and ALB, respectively. By applying the same procedure of iterative convolution to these frequency functions, we obtain the dilution curve of THO in the extravascular lung space. As a result of this analysis: (a) forward extrapolation is less subject to systematic errors such as overestimation of the mean transit time of ALB, i.e. of the tracer that recirculates more; and (b) the distribution volume of THO can be better defined since the dilution of THO in the extravascular lung space may be followed beyond the point of recirculation. The results indicate that both in normal subjects and in patients with left ventricular insufficiency the computed dilution curves of THO in the extravascular lung space have a long tail which is more pronounced in the patients. These findings suggest the existence in the lungs of extravascular water pools that are slowly exchanging with pulmonary water flow. This may depend both on inhomogeneities of perfusion, with lack of it at

  3. Sampling design and procedures for fixed surface-water sites in the Georgia-Florida coastal plain study unit, 1993

    Science.gov (United States)

    Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.

    1995-01-01

    The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of

  4. Monitoring of fluoride in water samples using a smartphone

    Energy Technology Data Exchange (ETDEWEB)

    Levin, Saurabh [Akvo Foundation (Netherlands); Krishnan, Sunderrajan [INREM Foundation (India); Rajkumar, Samuel; Halery, Nischal; Balkunde, Pradeep [Akvo Foundation (Netherlands)

    2016-05-01

    In several parts of India, groundwater is the only reliable, year round source for drinking water. Prevention of fluorosis, a chronic disease resulting from excess intake of fluoride, requires the screening of all groundwater sources for fluoride in endemic areas. In this paper, the authors present a field deployable colorimetric analyzer based on an inexpensive smartphone embedded with digital camera for taking photograph of the colored solution as well as an easy-fit, and compact sample chamber (Akvo Caddisfly). Phones marketed by different smartphone makers were used. Commercially available zirconium xylenol orange reagent was used for determining fluoride concentration. A software program was developed to use with the phone for recording and analyzing the RGB color of the picture. Linear range for fluoride estimation was 0–2 mg l{sup −1}. Around 200 samples, which consisted of laboratory prepared as well as field samples collected from different locations in Karnataka, India, were tested with Akvo Caddisfly. The results showed a significant positive correlation between Ion Selective Electrode (ISE) method and Akvo Caddisfly (Phones A, B and C), with correlation coefficient ranging between 0.9952 and 1.000. In addition, there was no significant difference in the mean fluoride content values between ISE and Phone B and C except for Phone A. Thus the smartphone method is economical and suited for groundwater fluoride analysis in the field. - Highlights: • Fluoride is an inorganic pollutant in ground water, affecting human health. • A colorimetric method for measurement of fluoride in drinking water with smartphone • Measurement is by mixing water with zirconyl xylenol orange complex reagent. • Results are comparable with laboratory-based ion selective fluoride electrode method.

  5. Monitoring of fluoride in water samples using a smartphone

    International Nuclear Information System (INIS)

    Levin, Saurabh; Krishnan, Sunderrajan; Rajkumar, Samuel; Halery, Nischal; Balkunde, Pradeep

    2016-01-01

    In several parts of India, groundwater is the only reliable, year round source for drinking water. Prevention of fluorosis, a chronic disease resulting from excess intake of fluoride, requires the screening of all groundwater sources for fluoride in endemic areas. In this paper, the authors present a field deployable colorimetric analyzer based on an inexpensive smartphone embedded with digital camera for taking photograph of the colored solution as well as an easy-fit, and compact sample chamber (Akvo Caddisfly). Phones marketed by different smartphone makers were used. Commercially available zirconium xylenol orange reagent was used for determining fluoride concentration. A software program was developed to use with the phone for recording and analyzing the RGB color of the picture. Linear range for fluoride estimation was 0–2 mg l"−"1. Around 200 samples, which consisted of laboratory prepared as well as field samples collected from different locations in Karnataka, India, were tested with Akvo Caddisfly. The results showed a significant positive correlation between Ion Selective Electrode (ISE) method and Akvo Caddisfly (Phones A, B and C), with correlation coefficient ranging between 0.9952 and 1.000. In addition, there was no significant difference in the mean fluoride content values between ISE and Phone B and C except for Phone A. Thus the smartphone method is economical and suited for groundwater fluoride analysis in the field. - Highlights: • Fluoride is an inorganic pollutant in ground water, affecting human health. • A colorimetric method for measurement of fluoride in drinking water with smartphone • Measurement is by mixing water with zirconyl xylenol orange complex reagent. • Results are comparable with laboratory-based ion selective fluoride electrode method.

  6. In-Situ Systematic Error Correction for Digital Volume Correlation Using a Reference Sample

    KAUST Repository

    Wang, B.

    2017-11-27

    The self-heating effect of a laboratory X-ray computed tomography (CT) scanner causes slight change in its imaging geometry, which induces translation and dilatation (i.e., artificial displacement and strain) in reconstructed volume images recorded at different times. To realize high-accuracy internal full-field deformation measurements using digital volume correlation (DVC), these artificial displacements and strains associated with unstable CT imaging must be eliminated. In this work, an effective and easily implemented reference sample compensation (RSC) method is proposed for in-situ systematic error correction in DVC. The proposed method utilizes a stationary reference sample, which is placed beside the test sample to record the artificial displacement fields caused by the self-heating effect of CT scanners. The detected displacement fields are then fitted by a parametric polynomial model, which is used to remove the unwanted artificial deformations in the test sample. Rescan tests of a stationary sample and real uniaxial compression tests performed on copper foam specimens demonstrate the accuracy, efficacy, and practicality of the presented RSC method.

  7. In-Situ Systematic Error Correction for Digital Volume Correlation Using a Reference Sample

    KAUST Repository

    Wang, B.; Pan, B.; Lubineau, Gilles

    2017-01-01

    The self-heating effect of a laboratory X-ray computed tomography (CT) scanner causes slight change in its imaging geometry, which induces translation and dilatation (i.e., artificial displacement and strain) in reconstructed volume images recorded at different times. To realize high-accuracy internal full-field deformation measurements using digital volume correlation (DVC), these artificial displacements and strains associated with unstable CT imaging must be eliminated. In this work, an effective and easily implemented reference sample compensation (RSC) method is proposed for in-situ systematic error correction in DVC. The proposed method utilizes a stationary reference sample, which is placed beside the test sample to record the artificial displacement fields caused by the self-heating effect of CT scanners. The detected displacement fields are then fitted by a parametric polynomial model, which is used to remove the unwanted artificial deformations in the test sample. Rescan tests of a stationary sample and real uniaxial compression tests performed on copper foam specimens demonstrate the accuracy, efficacy, and practicality of the presented RSC method.

  8. Condensate and feedwater systems, pumps, and water chemistry. Volume seven

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Subject matter includes condensate and feedwater systems (general features of condensate and feedwater systems, condenser hotwell level control, condensate flow, feedwater flow), pumps (principles of fluid flow, types of pumps, centrifugal pumps, positive displacement pumps, jet pumps, pump operating characteristics) and water chemistry (water chemistry fundamentals, corrosion, scaling, radiochemistry, water chemistry control processes, water pretreatment, PWR water chemistry, BWR water chemistry, condenser circulating water chemistry

  9. Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples

    Directory of Open Access Journals (Sweden)

    Nataša Gros

    2013-06-01

    Full Text Available This review focuses on the ion chromatographic methods for the analyses of natural waters with high ionic strength. At the beginning a natural diversity in ionic composition of waters is highlighted and terminology clarified. In continuation a brief overview of other review articles of potential interest is given. A review of ion chromatographic methods is organized in four sections. The first section comprises articles focused on the determination of ionic composition of water samples as completely as possible. The sections—Selected Anions, Selected Cations and Metals—follow. The most essential experimental conditions used in different methods are summarized in tables for a rapid comparison. Techniques encountered in the reviewed articles comprise: direct determinations of ions in untreated samples with ion- or ion-exclusion chromatography, or electrostatic ion chromatography; matrix elimination with column-switching; pre-concentration with a chelation ion chromatography and purge-and-trap pre-concentration. Different detection methods were used: non-suppressed conductometric or suppressed conductometric, direct spectrometric or spectrometric after a post-column derivetization, and inductively coupled plasma in combination with optical emission or mass spectrometry.

  10. Characterization of hazardous waste sites: a methods manual. Volume 2. Available sampling methods (second edition)

    International Nuclear Information System (INIS)

    Ford, P.J.; Turina, P.J.; Seely, D.E.

    1984-12-01

    Investigations at hazardous waste sites and sites of chemical spills often require on-site measurements and sampling activities to assess the type and extent of contamination. This document is a compilation of sampling methods and materials suitable to address most needs that arise during routine waste site and hazardous spill investigations. The sampling methods presented in this document are compiled by media, and were selected on the basis of practicality, economics, representativeness, compatability with analytical considerations, and safety, as well as other criteria. In addition to sampling procedures, sample handling and shipping, chain-of-custody procedures, instrument certification, equipment fabrication, and equipment decontamination procedures are described. Sampling methods for soil, sludges, sediments, and bulk materials cover the solids medium. Ten methods are detailed for surface waters, groundwater and containerized liquids; twelve are presented for ambient air, soil gases and vapors, and headspace gases. A brief discussion of ionizing radiation survey instruments is also provided

  11. Differences in microbial community composition between injection and production water samples of water flooding petroleum reservoirs

    Directory of Open Access Journals (Sweden)

    P. K. Gao

    2015-06-01

    Full Text Available Microbial communities in injected water are expected to have significant influence on those of reservoir strata in long-term water flooding petroleum reservoirs. To investigate the similarities and differences in microbial communities in injected water and reservoir strata, high-throughput sequencing of microbial partial 16S rRNA of the water samples collected from the wellhead and downhole of injection wells, and from production wells in a homogeneous sandstone reservoir and a heterogeneous conglomerate reservoir were performed. The results indicate that a small number of microbial populations are shared between the water samples from the injection and production wells in the sandstone reservoir, whereas a large number of microbial populations are shared in the conglomerate reservoir. The bacterial and archaeal communities in the reservoir strata have high concentrations, which are similar to those in the injected water. However, microbial population abundance exhibited large differences between the water samples from the injection and production wells. The number of shared populations reflects the influence of microbial communities in injected water on those in reservoir strata to some extent, and show strong association with the unique variation of reservoir environments.

  12. Nuclear power plants and the environment. Water samplings and releases

    International Nuclear Information System (INIS)

    Hartmann, Philippe; Bordet, Francois; Chevalier, Christian; Colin, Jean-Luc; Khalanski, Michel

    2013-01-01

    This voluminous and illustrated guide aims at giving detailed information on the nature of waters used by nuclear power plants and of releases, on how these samplings and controls are performed, on the associated risks for the environment and public health, and on how public is informed. After a general overview of these issues, a chapter addresses the protection of nature and biodiversity and the actions performed by EDF in this respect. The next chapter deals with public information. The next chapters discuss the water needs of a nuclear power plant, effluent releases and their impacts. Two chapters are dedicated to the monitoring and control of the environment, and to the various techniques of environmental metrology. Legal and regulatory aspects are then presented

  13. Effect of water volume based on water absorption and mixing time on physical properties of tapioca starch – wheat composite bread

    Science.gov (United States)

    Prameswari, I. K.; Manuhara, G. J.; Amanto, B. S.; Atmaka, W.

    2018-05-01

    Tapioca starch application in bread processing change water absorption level by the dough, while sufficient mixing time makes the optimal water absorption. This research aims to determine the effect of variations in water volume and mixing time on physical properties of tapioca starch – wheat composite bread and the best method for the composite bread processing. This research used Complete Randomized Factorial Design (CRFD) with two factors: variations of water volume (111,8 ml, 117,4 ml, 123 ml) and mixing time (16 minutes, 17 minutes 36 seconds, 19 minutes 12 seconds). The result showed that water volume significantly affected on dough volume, bread volume and specific volume, baking expansion, and crust thickness. Mixing time significantly affected on dough volume and specific volume, bread volume and specific volume, baking expansion, bread height, and crust thickness. While the combination of water volume and mixing time significantly affected for all physical properties parameters except crust thickness.

  14. Determining volume sensitive waters in Beaufort County, SC tidal creeks

    Science.gov (United States)

    Andrew Tweel; Denise Sanger; Anne Blair; John Leffler

    2016-01-01

    Non-point source pollution from stormwater runoff associated with large-scale land use changes threatens the integrity of ecologically and economically valuable estuarine ecosystems. Beaufort County, SC implemented volume-based stormwater regulations on the rationale that if volume discharge is controlled, contaminant loading will also be controlled.

  15. UMTRA Project water sampling and analysis plan, Salt Lake City, Utah. Revision 1

    International Nuclear Information System (INIS)

    1995-06-01

    This water sampling and analysis plan describes planned, routine ground water sampling activities at the US Department of Energy Uranium Mill Tailings Remedial Action Project site in Salt Lake City, Utah. This plan identifies and justifies sampling locations, analytical parameters, detection limits, and sampling frequencies for routine monitoring of ground water, sediments, and surface waters at monitoring stations on the site

  16. Transfer function design based on user selected samples for intuitive multivariate volume exploration

    KAUST Repository

    Zhou, Liang; Hansen, Charles

    2013-01-01

    Multivariate volumetric datasets are important to both science and medicine. We propose a transfer function (TF) design approach based on user selected samples in the spatial domain to make multivariate volumetric data visualization more accessible for domain users. Specifically, the user starts the visualization by probing features of interest on slices and the data values are instantly queried by user selection. The queried sample values are then used to automatically and robustly generate high dimensional transfer functions (HDTFs) via kernel density estimation (KDE). Alternatively, 2D Gaussian TFs can be automatically generated in the dimensionality reduced space using these samples. With the extracted features rendered in the volume rendering view, the user can further refine these features using segmentation brushes. Interactivity is achieved in our system and different views are tightly linked. Use cases show that our system has been successfully applied for simulation and complicated seismic data sets. © 2013 IEEE.

  17. Transfer function design based on user selected samples for intuitive multivariate volume exploration

    KAUST Repository

    Zhou, Liang

    2013-02-01

    Multivariate volumetric datasets are important to both science and medicine. We propose a transfer function (TF) design approach based on user selected samples in the spatial domain to make multivariate volumetric data visualization more accessible for domain users. Specifically, the user starts the visualization by probing features of interest on slices and the data values are instantly queried by user selection. The queried sample values are then used to automatically and robustly generate high dimensional transfer functions (HDTFs) via kernel density estimation (KDE). Alternatively, 2D Gaussian TFs can be automatically generated in the dimensionality reduced space using these samples. With the extracted features rendered in the volume rendering view, the user can further refine these features using segmentation brushes. Interactivity is achieved in our system and different views are tightly linked. Use cases show that our system has been successfully applied for simulation and complicated seismic data sets. © 2013 IEEE.

  18. In situ sampling of small volumes of soil solution using modified micro-suction cups

    NARCIS (Netherlands)

    Shen, Jianbo; Hoffland, E.

    2007-01-01

    Two modified designs of micro-pore-water samplers were tested for their capacity to collect unbiased soil solution samples containing zinc and citrate. The samplers had either ceramic or polyethersulfone (PES) suction cups. Laboratory tests of the micro-samplers were conducted using (a) standard

  19. SAMPL5: 3D-RISM partition coefficient calculations with partial molar volume corrections and solute conformational sampling.

    Science.gov (United States)

    Luchko, Tyler; Blinov, Nikolay; Limon, Garrett C; Joyce, Kevin P; Kovalenko, Andriy

    2016-11-01

    Implicit solvent methods for classical molecular modeling are frequently used to provide fast, physics-based hydration free energies of macromolecules. Less commonly considered is the transferability of these methods to other solvents. The Statistical Assessment of Modeling of Proteins and Ligands 5 (SAMPL5) distribution coefficient dataset and the accompanying explicit solvent partition coefficient reference calculations provide a direct test of solvent model transferability. Here we use the 3D reference interaction site model (3D-RISM) statistical-mechanical solvation theory, with a well tested water model and a new united atom cyclohexane model, to calculate partition coefficients for the SAMPL5 dataset. The cyclohexane model performed well in training and testing ([Formula: see text] for amino acid neutral side chain analogues) but only if a parameterized solvation free energy correction was used. In contrast, the same protocol, using single solute conformations, performed poorly on the SAMPL5 dataset, obtaining [Formula: see text] compared to the reference partition coefficients, likely due to the much larger solute sizes. Including solute conformational sampling through molecular dynamics coupled with 3D-RISM (MD/3D-RISM) improved agreement with the reference calculation to [Formula: see text]. Since our initial calculations only considered partition coefficients and not distribution coefficients, solute sampling provided little benefit comparing against experiment, where ionized and tautomer states are more important. Applying a simple [Formula: see text] correction improved agreement with experiment from [Formula: see text] to [Formula: see text], despite a small number of outliers. Better agreement is possible by accounting for tautomers and improving the ionization correction.

  20. SAMPL5: 3D-RISM partition coefficient calculations with partial molar volume corrections and solute conformational sampling

    Science.gov (United States)

    Luchko, Tyler; Blinov, Nikolay; Limon, Garrett C.; Joyce, Kevin P.; Kovalenko, Andriy

    2016-11-01

    Implicit solvent methods for classical molecular modeling are frequently used to provide fast, physics-based hydration free energies of macromolecules. Less commonly considered is the transferability of these methods to other solvents. The Statistical Assessment of Modeling of Proteins and Ligands 5 (SAMPL5) distribution coefficient dataset and the accompanying explicit solvent partition coefficient reference calculations provide a direct test of solvent model transferability. Here we use the 3D reference interaction site model (3D-RISM) statistical-mechanical solvation theory, with a well tested water model and a new united atom cyclohexane model, to calculate partition coefficients for the SAMPL5 dataset. The cyclohexane model performed well in training and testing (R=0.98 for amino acid neutral side chain analogues) but only if a parameterized solvation free energy correction was used. In contrast, the same protocol, using single solute conformations, performed poorly on the SAMPL5 dataset, obtaining R=0.73 compared to the reference partition coefficients, likely due to the much larger solute sizes. Including solute conformational sampling through molecular dynamics coupled with 3D-RISM (MD/3D-RISM) improved agreement with the reference calculation to R=0.93. Since our initial calculations only considered partition coefficients and not distribution coefficients, solute sampling provided little benefit comparing against experiment, where ionized and tautomer states are more important. Applying a simple pK_{ {a}} correction improved agreement with experiment from R=0.54 to R=0.66, despite a small number of outliers. Better agreement is possible by accounting for tautomers and improving the ionization correction.

  1. Experimental equivalent cluster-size distributions in nano-metric volumes of liquid water

    International Nuclear Information System (INIS)

    Grosswendt, B.; De Nardo, L.; Colautti, P.; Pszona, S.; Conte, V.; Tornielli, G.

    2004-01-01

    Ionisation cluster-size distributions in nano-metric volumes of liquid water were determined for alpha particles at 4.6 and 5.4 MeV by measuring cluster-size frequencies in small gaseous volumes of nitrogen or propane at low gas pressure as well as by applying a suitable scaling procedure. This scaling procedure was based on the mean free ionisation lengths of alpha particles in water and in the gases measured. For validation, the measurements of cluster sizes in gaseous volumes and the cluster-size formation in volumes of liquid water of equivalent size were simulated by Monte Carlo methods. The experimental water-equivalent cluster-size distributions in nitrogen and propane are compared with those in liquid water and show that cluster-size formation by alpha particles in nitrogen or propane can directly be related to those in liquid water. (authors)

  2. Determination of 222Rn in water samples from wells and springs in Tokyo by a modified integral counting method

    International Nuclear Information System (INIS)

    Homma, Y.; Murase, Y.; Handa, K.; Murakami, I.

    1997-01-01

    222 Rn in 2L-water samples was extracted with 30 mL toluene, and 21 mL of the toluene solution was transferred into a liquid scintillation vial, in which PPO - 2,5-diphenyloxazole was placed in advance. The total activity of 222 Rn in the water sample was calculated based on the Ostwald's coefficient of solubilities of 222 Rn in toluene and water at the temperature of the sample water and the volume of water and toluene. About 40% of 222 Rn dissolved in 2L-water sample can be collected. After allowing to stand for 3.5 h, the equilibrium mixture of 222 Rn and its daughters was measured with an Aloka liquid scintillation spectrometer using a modified integral counting method which extrapolates the integral counting curve not to the zero pulse-height, but to the zero detection threshold, an average energy required to produce a measurable pulse, of the liquid scintillation spectrometer. The general method which agitates water sample (usually about 10 mL) with a liquid scintillation cocktail is practical when the activity of 222 Rn is high. By adding 10 mL of water sample, however, it is possible also to add variable amounts of quencher. In some cases water sample is preserved with nitric acid. The slope of the integral counting rate curve increases as quench level of the sample increases. Therefore, it is clear that the modified integral counting method gives more accurate 222 Rn concentrations for water samples of strong quench than the conventional integral counting method. 222 Rn sample of 0.2 Bq/L can be determined within an overall uncertainty of 3.1%

  3. Water resources data, Idaho, 2004; Volume 1. Surface water records for Great Basin and Snake River basin above King Hill

    Science.gov (United States)

    Brennan, T.S.; Lehmann, A.K.; O'Dell, I.

    2005-01-01

    Water resources data for the 2004 water year for Idaho consists of records of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes and reservoirs; discharge of irrigation diversions; and water levels and water quality of groundwater. The three volumes of this report contain discharge records for 209 stream-gaging stations and 8 irrigation diversions; stage only records for 6 stream-gaging stations; stage only for 6 lakes and reservoirs; contents only for 13 lakes and reservoirs; water-quality for 39 stream-gaging stations and partial record sites, 3 lakes sites, and 395 groundwater wells; and water levels for 425 observation network wells and 900 special project wells. Additional water data were collected at various sites not involved in the systematic data collection program and are published as miscellaneous measurements. Volumes 1 & 2 contain the surface-water and surface-water-quality records. Volume 3 contains the ground-water and ground-water-quality records. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in Idaho, adjacent States, and Canada.

  4. Water resources data, Idaho, 2003; Volume 1. Surface water records for Great Basin and Snake River basin above King Hill

    Science.gov (United States)

    Brennan, T.S.; Lehmann, A.K.; O'Dell, I.

    2004-01-01

    Water resources data for the 2003 water year for Idaho consists of records of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes and reservoirs; discharge of irrigation diversions; and water levels and water quality of groundwater. The three volumes of this report contain discharge records for 208 stream-gaging stations and 14 irrigation diversions; stage only records for 6 stream-gaging stations; stage only for 6 lakes and reservoirs; contents only for 13 lakes and reservoirs; water-quality for 50 stream-gaging stations and partial record sites, 3 lakes sites, and 398 groundwater wells; and water levels for 427 observation network wells and 900 special project wells. Additional water data were collected at various sites not involved in the systematic data collection program and are published as miscellaneous measurements. Volumes 1 & 2 contain the surface-water and surface-water-quality records. Volume 3 contains the ground-water and ground-water-quality records. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in Idaho, adjacent States, and Canada.

  5. Investigation results on water quality and volume of flowing-in water to the Yotsugi slag heap site. 2

    International Nuclear Information System (INIS)

    Naganuma, Masaki; Taki, Tomihiro; Takimoto, Sadao; Makita, A.

    2000-05-01

    Mining water flowing into the Yotsugi slag heap site at the Ningyo-toge Environment Technical Center is exhausted to a common river after carrying out the treatment of uranium and radium in the mining water at the previously settled mining water treatment facility and confirming it to be less than management target value on the river water within the site boundary regulated by the agreement on environmental conservation with Okayama prefecture and Kami-saihara mura. In order to elucidate some required treatment on every water system flowing-in the heap site as a part of reduction of flowing volume on taking action of the heap site, an investigation on its water quality and volume was carried out. As a result, it was confirmed on water quality that uranium values of every river were all less than their target values but radium values of them were all over their target values which necessitated conventional water treatment. And, on water volume, it was confirmed that flowing water volume from the exposed excavation site was reduced about 40% in comparison with same rain-fall before removing from rain water. (G.K.)

  6. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    Science.gov (United States)

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Automated high-volume aerosol sampling station for environmental radiation monitoring

    International Nuclear Information System (INIS)

    Toivonen, H.; Honkamaa, T.; Ilander, T.; Leppaenen, A.; Nikkinen, M.; Poellaenen, R.; Ylaetalo, S.

    1998-07-01

    An automated high-volume aerosol sampling station, known as CINDERELLA.STUK, for environmental radiation monitoring has been developed by the Radiation and Nuclear Safety Authority (STUK), Finland. The sample is collected on a glass fibre filter (attached into a cassette), the airflow through the filter is 800 m 3 /h at maximum. During the sampling, the filter is continuously monitored with Na(I) scintillation detectors. After the sampling, the large filter is automatically cut into 15 pieces that form a small sample and after ageing, the pile of filter pieces is moved onto an HPGe detector. These actions are performed automatically by a robot. The system is operated at a duty cycle of 1 d sampling, 1 d decay and 1 d counting. Minimum detectable concentrations of radionuclides in air are typically 1Ae10 x 10 -6 Bq/m 3 . The station is equipped with various sensors to reveal unauthorized admittance. These sensors can be monitored remotely in real time via Internet or telephone lines. The processes and operation of the station are monitored and partly controlled by computer. The present approach fulfils the requirements of CTBTO for aerosol monitoring. The concept suits well for nuclear material safeguards, too

  8. Sampling of high amounts of bioaerosols using a high-volume electrostatic field sampler

    DEFF Research Database (Denmark)

    Madsen, A. M.; Sharma, Anoop Kumar

    2008-01-01

    For studies of the biological effects of bioaerosols, large samples are necessary. To be able to sample enough material and to cover the variations in aerosol content during and between working days, a long sampling time is necessary. Recently, a high-volume transportable electrostatic field...... and 315 mg dust (net recovery of the lyophilized dust) was sampled during a period of 7 days, respectively. The sampling rates of the electrostatic field samplers were between 1.34 and 1.96 mg dust per hour, the value for the Gravikon was between 0.083 and 0.108 mg dust per hour and the values for the GSP...... samplers were between 0.0031 and 0.032 mg dust per hour. The standard deviations of replica samplings and the following microbial analysis using the electrostatic field sampler and GSP samplers were at the same levels. The exposure to dust in the straw storage was 7.7 mg m(-3) when measured...

  9. Sampling tritiated water vapor from the atmosphere by an active system using silica gel

    Energy Technology Data Exchange (ETDEWEB)

    Herranz, M. [Department of Nuclear Engineering and Fluid Mechanics, E.T.S.I. de Bilbao, University of the Basque Country (UPV/EHU), Alameda de Urquijo, s/n 48013 Bilbao (Spain); Alegria, N., E-mail: natalia.alegria@ehu.es [Department of Nuclear Engineering and Fluid Mechanics, E.T.S.I. de Bilbao, University of the Basque Country (UPV/EHU), Alameda de Urquijo, s/n 48013 Bilbao (Spain); Idoeta, R.; Legarda, F. [Department of Nuclear Engineering and Fluid Mechanics, E.T.S.I. de Bilbao, University of the Basque Country (UPV/EHU), Alameda de Urquijo, s/n 48013 Bilbao (Spain)

    2011-11-15

    Among the different methods used to collect the tritiated water vapor (HTO) contained in the atmosphere, one of the most worldwide used is its collection using an air pump, which forces the air to pass through a dry silica gel trap. The silica gel is then distilled to remove the water collected, which is measured in a liquid scintillation counting system. In this paper, an analysis of the water collection efficiency of the silica gel has been done as a function of the temperatures involved, the dimensions of the pipe driving the air into the silica gel traps, the air volume passing through the trap and the flow rates used. Among the obtained conclusions, it can be pointed out that placing the traps inside a cooled container, the amount of silica gel needed to collect all the water contained in the air passing through these traps can be estimated using a weather forecast and a psychometric chart. To do this, and as thermal equilibrium between incoming and open air should be established, a suitable design of the sampling system is proposed. - Highlights: > To recollect the atmosphere air tritiated water vapor, an active system was used. > The system is an air pump and three traps with silica gel connected by a rubber pipe. > The silica gel retention depends on the meteorological conditions and the flow rate. > The amount of water collected and the mass of silica gel need were calculated, F.

  10. Analysis of plant hormones by microemulsion electrokinetic capillary chromatography coupled with on-line large volume sample stacking.

    Science.gov (United States)

    Chen, Zongbao; Lin, Zian; Zhang, Lin; Cai, Yan; Zhang, Lan

    2012-04-07

    A novel method of microemulsion electrokinetic capillary chromatography (MEEKC) coupled with on-line large volume sample stacking was developed for the analysis of six plant hormones including indole-3-acetic acid, indole-3-butyric acid, indole-3-propionic acid, 1-naphthaleneacetic acid, abscisic acid and salicylic acid. Baseline separation of six plant hormones was achieved within 10 min by using the microemulsion background electrolyte containing a 97.2% (w/w) 10 mM borate buffer at pH 9.2, 1.0% (w/w) ethyl acetate as oil droplets, 0.6% (w/w) sodium dodecyl sulphate as surfactant and 1.2% (w/w) 1-butanol as cosurfactant. In addition, an on-line concentration method based on a large volume sample stacking technique and multiple wavelength detection was adopted for improving the detection sensitivity in order to determine trace level hormones in a real sample. The optimal method provided about 50-100 fold increase in detection sensitivity compared with a single MEEKC method, and the detection limits (S/N = 3) were between 0.005 and 0.02 μg mL(-1). The proposed method was simple, rapid and sensitive and could be applied to the determination of six plant hormones in spiked water samples, tobacco leaves and 1-naphthylacetic acid in leaf fertilizer. The recoveries ranged from 76.0% to 119.1%, and good reproducibilities were obtained with relative standard deviations (RSDs) less than 6.6%.

  11. Relationship between LIBS Ablation and Pit Volume for Geologic Samples: Applications for in situ Absolute Geochronology

    Science.gov (United States)

    Devismes, D.; Cohen, Barbara A.

    2014-01-01

    In planetary sciences, in situ absolute geochronology is a scientific and engineering challenge. Currently, the age of the Martian surface can only be determined by crater density counting. However this method has significant uncertainties and needs to be calibrated with absolute ages. We are developing an instrument to acquire in situ absolute geochronology based on the K-Ar method. The protocol is based on the laser ablation of a rock by hundreds of laser pulses. Laser Induced Breakdown Spectroscopy (LIBS) gives the potassium content of the ablated material and a mass spectrometer (quadrupole or ion trap) measures the quantity of 40Ar released. In order to accurately measure the quantity of released 40Ar in cases where Ar is an atmospheric constituent (e.g., Mars), the sample is first put into a chamber under high vacuum. The 40Arquantity, the concentration of K and the estimation of the ablated mass are the parameters needed to give the age of the rocks. The main uncertainties with this method are directly linked to the measures of the mass (typically some µg) and of the concentration of K by LIBS (up to 10%). Because the ablated mass is small compared to the mass of the sample, and because material is redeposited onto the sample after ablation, it is not possible to directly measure the ablated mass. Our current protocol measures the ablated volume and estimates the sample density to calculate ablated mass. The precision and accuracy of this method may be improved by using knowledge of the sample's geologic properties to predict its response to laser ablation, i.e., understanding whether natural samples have a predictable relationship between laser energy deposited and resultant ablation volume. In contrast to most previous studies of laser ablation, theoretical equations are not highly applicable. The reasons are numerous, but the most important are: a) geologic rocks are complex, polymineralic materials; b) the conditions of ablation are unusual (for example

  12. Computational methods and modeling. 1. Sampling a Position Uniformly in a Trilinear Hexahedral Volume

    International Nuclear Information System (INIS)

    Urbatsch, Todd J.; Evans, Thomas M.; Hughes, H. Grady

    2001-01-01

    Monte Carlo particle transport plays an important role in some multi-physics simulations. These simulations, which may additionally involve deterministic calculations, typically use a hexahedral or tetrahedral mesh. Trilinear hexahedrons are attractive for physics calculations because faces between cells are uniquely defined, distance-to-boundary calculations are deterministic, and hexahedral meshes tend to require fewer cells than tetrahedral meshes. We discuss one aspect of Monte Carlo transport: sampling a position in a tri-linear hexahedron, which is made up of eight control points, or nodes, and six bilinear faces, where each face is defined by four non-coplanar nodes in three-dimensional Cartesian space. We derive, code, and verify the exact sampling method and propose an approximation to it. Our proposed approximate method uses about one-third the memory and can be twice as fast as the exact sampling method, but we find that its inaccuracy limits its use to well-behaved hexahedrons. Daunted by the expense of the exact method, we propose an alternate approximate sampling method. First, calculate beforehand an approximate volume for each corner of the hexahedron by taking one-eighth of the volume of an imaginary parallelepiped defined by the corner node and the three nodes to which it is directly connected. For the sampling, assume separability in the parameters, and sample each parameter, in turn, from a linear pdf defined by the sum of the four corner volumes at each limit (-1 and 1) of the parameter. This method ignores the quadratic portion of the pdf, but it requires less storage, has simpler sampling, and needs no extra, on-the-fly calculations. We simplify verification by designing tests that consist of one or more cells that entirely fill a unit cube. Uniformly sampling complicated cells that fill a unit cube will result in uniformly sampling the unit cube. Unit cubes are easily analyzed. The first problem has four wedges (or tents, or A frames) whose

  13. Sampling problems and the determination of mercury in surface water, seawater, and air

    International Nuclear Information System (INIS)

    Das, H.A.; van der Sloot, H.A.

    1976-01-01

    Analysis of surface water for mercury comprises the determination of both ionic and organically bound mercury in solution and that of the total mercury content of the suspended matter. Eventually, metallic mercury has to be determined too. Requirements for the sampling procedure are given. A method for the routine determination of mercury in surface water and seawater was developed and applied to Dutch surface waters. The total sample volume is 2500 ml. About 500 ml is used for the determination of the content of suspended matter and the total amount of mercury in the water. The sample is filtered through a bed of previously purified active charcoal at a low flow-rate. The main portion ca. 2000 ml) passes a flow-through centrifuge to separate the solid fraction. One liter is used to separate ''inorganic'' mercury by reduction, volatilization in an airstream and adsorption on active charcoal. The other liter is led through a column of active charcoal to collect all mercury. The procedures were checked with 197 Hg radiotracer both as an ion and incorporated in organic compounds. The mercury is determined by thermal neutron activation, followed by volatilization in a tube furnace and adsorption on a fresh carbon bed. The limit of determination is approximately equal to 1 ng 1 -1 . The rate of desorption from and adsorption on suspended material has been measured as a function of a pH of the solution for Hg +2 and various other ions. It can be concluded that only the procedure mentioned above does not disturb the equilibrium. The separation of mercury from air is obtained by suction of 1 m 3 through a 0.22 μm filter and a charcoal bed. The determination is then performed as in the case of the water samples

  14. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  15. Determination of 210Pb and 210Po in water samples

    International Nuclear Information System (INIS)

    Ayranov, M.; Tosheva, Z.; Kies, A.

    2004-01-01

    Lead-210 and Polonium-210 are naturally occurring members of the Uranium-238 decay series. They could be found in various environmental samples, such as groundwater, fish and shellfish, contributing an important component of the human natural radiation background. For this reason the development of a fast, reproducible and sensitive method for determination of 210 Pb and 210 Po is of a great concern. The aims of our study were to adopt procedures for radiochemical separation of these radionuclides and radioanalytical methods for their determination. The combination of electrochemical deposition, co-precipitation and extraction chromatography gives the opportunity for fast and effective radiochemical separation of the analytes. Polonium was spontaneously plated on copper disk from the stock solution. Lead was co-precipitated with Fe(OH) 3 and further purified by extraction chromatography on Sr Spec columns. Alpha spectra of polonium were collected on Canberra PIPS detectors with 900 mm 2 active surface. The activities of lead were determined by LSC (Gardian Wallac Oy). The minimum detectable activities for sample size 1000 mL and chemical yield of 88 % for the polonium and 85 % for the lead are presented. The proposed method proved to be fast, accurate and reproducible for routine determination of lead and polonium in environmental water samples. (authors)

  16. Note: Nonpolar solute partial molar volume response to attractive interactions with water.

    Science.gov (United States)

    Williams, Steven M; Ashbaugh, Henry S

    2014-01-07

    The impact of attractive interactions on the partial molar volumes of methane-like solutes in water is characterized using molecular simulations. Attractions account for a significant 20% volume drop between a repulsive Weeks-Chandler-Andersen and full Lennard-Jones description of methane interactions. The response of the volume to interaction perturbations is characterized by linear fits to our simulations and a rigorous statistical thermodynamic expression for the derivative of the volume to increasing attractions. While a weak non-linear response is observed, an average effective slope accurately captures the volume decrease. This response, however, is anticipated to become more non-linear with increasing solute size.

  17. Note: Nonpolar solute partial molar volume response to attractive interactions with water

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Steven M.; Ashbaugh, Henry S., E-mail: hanka@tulane.edu [Department of Chemical and Biomolecular Engineering, Tulane University, New Orleans, Louisiana 70118 (United States)

    2014-01-07

    The impact of attractive interactions on the partial molar volumes of methane-like solutes in water is characterized using molecular simulations. Attractions account for a significant 20% volume drop between a repulsive Weeks-Chandler-Andersen and full Lennard-Jones description of methane interactions. The response of the volume to interaction perturbations is characterized by linear fits to our simulations and a rigorous statistical thermodynamic expression for the derivative of the volume to increasing attractions. While a weak non-linear response is observed, an average effective slope accurately captures the volume decrease. This response, however, is anticipated to become more non-linear with increasing solute size.

  18. The Complete Local Volume Groups Sample - I. Sample selection and X-ray properties of the high-richness subsample

    Science.gov (United States)

    O'Sullivan, Ewan; Ponman, Trevor J.; Kolokythas, Konstantinos; Raychaudhury, Somak; Babul, Arif; Vrtilek, Jan M.; David, Laurence P.; Giacintucci, Simona; Gitti, Myriam; Haines, Chris P.

    2017-12-01

    We present the Complete Local-Volume Groups Sample (CLoGS), a statistically complete optically selected sample of 53 groups within 80 Mpc. Our goal is to combine X-ray, radio and optical data to investigate the relationship between member galaxies, their active nuclei and the hot intra-group medium (IGM). We describe sample selection, define a 26-group high-richness subsample of groups containing at least four optically bright (log LB ≥ 10.2 LB⊙) galaxies, and report the results of XMM-Newton and Chandra observations of these systems. We find that 14 of the 26 groups are X-ray bright, possessing a group-scale IGM extending at least 65 kpc and with luminosity >1041 erg s-1, while a further three groups host smaller galaxy-scale gas haloes. The X-ray bright groups have masses in the range M500 ≃ 0.5-5 × 1013 M⊙, based on system temperatures of 0.4-1.4 keV, and X-ray luminosities in the range 2-200 × 1041 erg s-1. We find that ∼53-65 per cent of the X-ray bright groups have cool cores, a somewhat lower fraction than found by previous archival surveys. Approximately 30 per cent of the X-ray bright groups show evidence of recent dynamical interactions (mergers or sloshing), and ∼35 per cent of their dominant early-type galaxies host active galactic nuclei with radio jets. We find no groups with unusually high central entropies, as predicted by some simulations, and confirm that CLoGS is in principle capable of detecting such systems. We identify three previously unrecognized groups, and find that they are either faint (LX, R500 < 1042 erg s-1) with no concentrated cool core, or highly disturbed. This leads us to suggest that ∼20 per cent of X-ray bright groups in the local universe may still be unidentified.

  19. A New Electropositive Filter for Concentrating Enterovirus and Norovirus from Large Volumes of Water - MCEARD

    Science.gov (United States)

    The detection of enteric viruses in environmental water usually requires the concentration of viruses from large volumes of water. The 1MDS electropositive filter is commonly used for concentrating enteric viruses from water but unfortunately these filters are not cost-effective...

  20. Remedial investigation sampling and analysis plan for J-Field, Aberdeen Proving Ground, Maryland. Volume 1: Field Sampling Plan

    Energy Technology Data Exchange (ETDEWEB)

    Benioff, P.; Biang, R.; Dolak, D.; Dunn, C.; Martino, L.; Patton, T.; Wang, Y.; Yuen, C.

    1995-03-01

    The Environmental Management Division (EMD) of Aberdeen Proving Ground (APG), Maryland, is conducting a remedial investigation and feasibility study (RI/FS) of the J-Field area at APG pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), as amended. J-Field is within the Edgewood Area of APG in Harford County, Maryland (Figure 1. 1). Since World War II activities in the Edgewood Area have included the development, manufacture, testing, and destruction of chemical agents and munitions. These materials were destroyed at J-Field by open burning and open detonation (OB/OD). Considerable archival information about J-Field exists as a result of efforts by APG staff to characterize the hazards associated with the site. Contamination of J-Field was first detected during an environmental survey of the Edgewood Area conducted in 1977 and 1978 by the US Army Toxic and Hazardous Materials Agency (USATHAMA) (predecessor to the US Army Environmental Center [AEC]). As part of a subsequent USATHAMA -environmental survey, 11 wells were installed and sampled at J-Field. Contamination at J-Field was also detected during a munitions disposal survey conducted by Princeton Aqua Science in 1983. The Princeton Aqua Science investigation involved the installation and sampling of nine wells and the collection and analysis of surficial and deep composite soil samples. In 1986, a Resource Conservation and Recovery Act (RCRA) permit (MD3-21-002-1355) requiring a basewide RCRA Facility Assessment (RFA) and a hydrogeologic assessment of J-Field was issued by the US Environmental Protection Agency (EPA). In 1987, the US Geological Survey (USGS) began a two-phased hydrogeologic assessment in data were collected to model, groundwater flow at J-Field. Soil gas investigations were conducted, several well clusters were installed, a groundwater flow model was developed, and groundwater and surface water monitoring programs were established that continue today.

  1. Regulation, characterization and treatment of discharge waters from pipelines. Volume 1. Topical report, January 1989-April 1992. Executive summary

    International Nuclear Information System (INIS)

    Tallon, J.T.; Fillo, J.P.

    1992-04-01

    The report examines environmental issues related to hydrostatic testing of discharge waters generated from integrity testing of natural gas pipelines. Hydrostatic testing, and proper environmental management of the discharge waters, can be required by DOT regulations. However, disposal of water used to conduct a hydrostatic pipeline test is regulated on a state-by-state basis. State-specific requirements vary widely, ranging from an authorization letter to a complete NPDES permit. Monitoring may be required before and during discharge, include a variety of analyses, have varying protocols for obtaining samples, and may be required either to obtain data or to ascertain compliance with stipulated discharge limits. The composition of the discharge and state-specific discharge limitations dictate treatment needs on a case-by-case basis. The volume consists of the Executive Summary of a five-volume report series

  2. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    Science.gov (United States)

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R 2 = 0.997). PMID:22567558

  3. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    Directory of Open Access Journals (Sweden)

    Eva Tavčar

    2012-01-01

    Full Text Available The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD=4.3%, accuracy, and linearity (2=0.997.

  4. Simple modification of karl-Fischer titration method for determination of water content in colored samples.

    Science.gov (United States)

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R(2) = 0.997).

  5. Solid phase extraction for determination of 90Sr in water sample

    International Nuclear Information System (INIS)

    Ometakova, J.

    2009-01-01

    We studied the use of an extraction chromatography for determination of 90 Sr in samples of contaminated water. The aim of the thesis was to compare selected products from the point of view of the strontium yields and time needed. Three commercial products: 3M Empore Strontium Rad Disk, AnaLig, Sr-Resin and two classical methods: liquid-liquid extraction with tributylphosphate and carbonate co-precipitation (to eliminate interferers) were used for separation of 90 Sr. The water sample was used in radiochemical analysis for determination volume activity of 90 Sr. A radiochemical strontium yield was traced by using radionuclide 85 Sr. Samples were counted over a two week period to monitor the ingrowth of 90 Y on TRI CARB LSC counter. Samples were measured using an HPGe detector to find out 85 Sr recoveries at 514 keV line and they were counted directly by Cherenkov counting after the growth of 90 Y using TriCarb LSC counter after a two- week period (author)

  6. Determination of trihalomethanes in water samples: A review

    Energy Technology Data Exchange (ETDEWEB)

    Perez Pavon, Jose Luis [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias Quimicas, Universidad de Salamanca, 37008 Salamanca (Spain)], E-mail: jlpp@usal.es; Herrero Martin, Sara; Garcia Pinto, Carmelo; Moreno Cordero, Bernardo [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias Quimicas, Universidad de Salamanca, 37008 Salamanca (Spain)

    2008-11-23

    This article reviews the most recent literature addressing the analytical methods applied for trihalomethanes (THMs) determination in water samples. This analysis is usually performed with gas chromatography (GC) combined with a preconcentration step. The detectors most widely used in this type of analyses are mass spectrometers (MS) and electron capture detectors (ECD). Here, we review the analytical characteristics, the time required for analysis, and the simplicity of the optimised methods. The main difference between these methods lies in the sample pretreatment step; therefore, special emphasis is placed on this aspect. The techniques covered are direct aqueous injection (DAI), liquid-liquid extraction (LLE), headspace (HS), and membrane-based techniques. We also review the main chromatographic columns employed and consider novel aspects of chromatographic analysis, such as the use of fast gas chromatography (FGC). Concerning the detection step, besides the common techniques, the use of uncommon detectors such as fluorescence detector, pulsed discharge photoionization detector (PDPID), dry electrolytic conductivity detector (DELCD), atomic emission detector (AED) and inductively coupled plasma-mass spectrometry (ICP-MS) for this type of analysis is described.

  7. Forsmark site investigation. Hydrochemical monitoring of groundwaters and surface waters. Results from water sampling in the Forsmark area, January-December 2009

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Ann-Chatrin (ed.); Berg, Cecilia; Harrstroem, Johan; Joensson, Stig; Thur, Pernilla (Geosigma AB (Sweden)); Borgiel, Micke; Qvarfordt, Susanne (Sveriges Vattenekologer AB (Sweden))

    2010-09-15

    The fifth year (2009) of hydrochemical monitoring of groundwaters, surface waters and precipitation in Forsmark is documented in the report. The hydrochemical monitoring programme 2009 included water sampling from: - percussion- and core boreholes equipped with installations for long-term pressure monitoring, tracer tests and water sampling in packed off borehole sections, sampling and analysis performed twice (spring and autumn), - near surface groundwaters (sampling four times a year), - private wells (once per year in October), - surface waters (eleven sampling occasions per year). Due to the somewhat different performance of the hydrogeochemical monitoring of the deep groundwaters during the autumn 2009 compared to previous years, some new findings and knowledge were obtained: 1) Removal of water volumes corresponding to three to five times the volume of the borehole section (the routine procedure) is seldom enough to obtain a complete exchange of the water present in the borehole section when the pumping starts. 2) It is likely that the elevated sulphide concentrations observed in the monitoring programme /1/ is due to contamination from initial water present in the borehole sections when the pumping starts. This water may have a very high sulphide concentration. Dirty water in tubes and in stand pipes may also contribute to the enhanced sulphide concentration. 3) Plug flow calculations will be introduced in the future as a new routine procedure to estimate the water volumes to be removed, in order to exchange the section water volume, prior to groundwater sampling in delimited borehole sections. During the autumn sampling, sample series of five samples per sampling location were collected during continuous pumping in thirteen selected borehole sections. Furthermore, special efforts were put on cleaning of stand pipes and exchange of water prior to sampling. The analytical protocol was rather extensive and included sulphide and uranium analyses for each sample

  8. Forsmark site investigation. Hydrochemical monitoring of groundwaters and surface waters. Results from water sampling in the Forsmark area, January-December 2009

    International Nuclear Information System (INIS)

    Nilsson, Ann-Chatrin; Borgiel, Micke; Qvarfordt, Susanne

    2010-09-01

    The fifth year (2009) of hydrochemical monitoring of groundwaters, surface waters and precipitation in Forsmark is documented in the report. The hydrochemical monitoring programme 2009 included water sampling from: - percussion- and core boreholes equipped with installations for long-term pressure monitoring, tracer tests and water sampling in packed off borehole sections, sampling and analysis performed twice (spring and autumn), - near surface groundwaters (sampling four times a year), - private wells (once per year in October), - surface waters (eleven sampling occasions per year). Due to the somewhat different performance of the hydrogeochemical monitoring of the deep groundwaters during the autumn 2009 compared to previous years, some new findings and knowledge were obtained: 1) Removal of water volumes corresponding to three to five times the volume of the borehole section (the routine procedure) is seldom enough to obtain a complete exchange of the water present in the borehole section when the pumping starts. 2) It is likely that the elevated sulphide concentrations observed in the monitoring programme /1/ is due to contamination from initial water present in the borehole sections when the pumping starts. This water may have a very high sulphide concentration. Dirty water in tubes and in stand pipes may also contribute to the enhanced sulphide concentration. 3) Plug flow calculations will be introduced in the future as a new routine procedure to estimate the water volumes to be removed, in order to exchange the section water volume, prior to groundwater sampling in delimited borehole sections. During the autumn sampling, sample series of five samples per sampling location were collected during continuous pumping in thirteen selected borehole sections. Furthermore, special efforts were put on cleaning of stand pipes and exchange of water prior to sampling. The analytical protocol was rather extensive and included sulphide and uranium analyses for each sample

  9. Sensitive determination of polycyclic aromatic hydrocarbons in water samples by HPLC coupled with SPE based on graphene functionalized with triethoxysilane.

    Science.gov (United States)

    Huang, Ke-Jing; Li, Jing; Liu, Yan-Ming; Wang, Lan

    2013-02-01

    The graphene functionalized with (3-aminopropyl) triethoxysilane was synthesized by a simple hydrothermal reaction and applied as SPE sorbents to extract trace polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. These sorbents possess high adsorption capacity and extraction efficiency due to strong adsorption ability of carbon materials and large specific surface area of nanoparticles, and only 10 mg of sorbents are required to extract PAHs from 100 mL water samples. Several condition parameters, such as eluent and its volume, adsorbent amount, sample volume, sample pH, and sample flow rate, were optimized to achieve good sensitivity and precision. Under the optimized extraction conditions, the method showed good linearity in the range of 1-100 μg/L, repeatability of the extraction (the RSDs were between 1.8 and 2.9%, n = 6), and satisfactory detection limits of 0.029-0.1 μg/L. The recoveries of PAHs spiked in environmental water samples ranged from 84.6 to 109.5%. All these results demonstrated that this new SPE technique was a viable alternative to conventional enrichment techniques for the extraction and analysis of PAHs in complex samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Sampling and analysis for radon-222 dissolved in ground water and surface water

    Science.gov (United States)

    DeWayne, Cecil L.; Gesell, T.F.

    1992-01-01

    Radon-222 is a naturally occurring radioactive gas in the uranium-238 decay series that has traditionally been called, simply, radon. The lung cancer risks associated with the inhalation of radon decay products have been well documented by epidemiological studies on populations of uranium miners. The realization that radon is a public health hazard has raised the need for sampling and analytical guidelines for field personnel. Several sampling and analytical methods are being used to document radon concentrations in ground water and surface water worldwide but no convenient, single set of guidelines is available. Three different sampling and analytical methods - bubbler, liquid scintillation, and field screening - are discussed in this paper. The bubbler and liquid scintillation methods have high accuracy and precision, and small analytical method detection limits of 0.2 and 10 pCi/l (picocuries per liter), respectively. The field screening method generally is used as a qualitative reconnaissance tool.

  11. Changes in apparent molar water volume and DKP solubility yield insights on the Hofmeister effect.

    Science.gov (United States)

    Payumo, Alexander Y; Huijon, R Michael; Mansfield, Deauna D; Belk, Laurel M; Bui, Annie K; Knight, Anne E; Eggers, Daryl K

    2011-12-15

    This study examines the properties of a 4 × 2 matrix of aqueous cations and anions at concentrations up to 8.0 M. The apparent molar water volume, as calculated by subtracting the mass and volume of the ions from the corresponding solution density, was found to exceed the molar volume of ice in many concentrated electrolyte solutions, underscoring the nonideal behavior of these systems. The solvent properties of water were also analyzed by measuring the solubility of diketopiperazine (DKP) in 2.000 M salt solutions prepared from the same ion combinations. Solution rankings for DKP solubility were found to parallel the Hofmeister series for both cations and anions, whereas molar water volume concurred with the cation series only. The results are discussed within the framework of a desolvation energy model that attributes solute-specific changes in equilibria to solute-dependent changes in the free energy of bulk water.

  12. Changes in Apparent Molar Water Volume and DKP Solubility Yield Insights on the Hofmeister Effect

    Science.gov (United States)

    Payumo, Alexander Y.; Huijon, R. Michael; Mansfield, Deauna D.; Belk, Laurel M.; Bui, Annie K.; Knight, Anne E.; Eggers, Daryl K.

    2011-01-01

    This study examines the properties of a 4 × 2 matrix of aqueous cations and anions at concentrations up to 8.0 M. The apparent molar water volume, as calculated by subtracting the mass and volume of the ions from the corresponding solution density, was found to exceed the molar volume of ice in many concentrated electrolyte solutions, underscoring the non-ideal behavior of these systems. The solvent properties of water were also analyzed by measuring the solubility of diketopiperazine (DKP) in 2.000 M salt solutions prepared from the same ion combinations. Solution rankings for DKP solubility were found to parallel the Hofmeister series for both cations and anions, whereas molar water volume concurred with the cation series only. The results are discussed within the framework of a desolvation energy model that attributes solute-specific changes in equilibria to solute-dependent changes in the free energy of bulk water. PMID:22029390

  13. Density-viscosity product of small-volume ionic liquid samples using quartz crystal impedance analysis.

    Science.gov (United States)

    McHale, Glen; Hardacre, Chris; Ge, Rile; Doy, Nicola; Allen, Ray W K; MacInnes, Jordan M; Bown, Mark R; Newton, Michael I

    2008-08-01

    Quartz crystal impedance analysis has been developed as a technique to assess whether room-temperature ionic liquids are Newtonian fluids and as a small-volume method for determining the values of their viscosity-density product, rho eta. Changes in the impedance spectrum of a 5-MHz fundamental frequency quartz crystal induced by a water-miscible room-temperature ionic liquid, 1-butyl-3-methylimiclazolium trifluoromethylsulfonate ([C4mim][OTf]), were measured. From coupled frequency shift and bandwidth changes as the concentration was varied from 0 to 100% ionic liquid, it was determined that this liquid provided a Newtonian response. A second water-immiscible ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [C4mim][NTf2], with concentration varied using methanol, was tested and also found to provide a Newtonian response. In both cases, the values of the square root of the viscosity-density product deduced from the small-volume quartz crystal technique were consistent with those measured using a viscometer and density meter. The third harmonic of the crystal was found to provide the closest agreement between the two measurement methods; the pure ionic liquids had the largest difference of approximately 10%. In addition, 18 pure ionic liquids were tested, and for 11 of these, good-quality frequency shift and bandwidth data were obtained; these 12 all had a Newtonian response. The frequency shift of the third harmonic was found to vary linearly with square root of viscosity-density product of the pure ionic liquids up to a value of square root(rho eta) approximately 18 kg m(-2) s(-1/2), but with a slope 10% smaller than that predicted by the Kanazawa and Gordon equation. It is envisaged that the quartz crystal technique could be used in a high-throughput microfluidic system for characterizing ionic liquids.

  14. Partial Molar Volume of Methanol in Water: Effect of Polarizability

    Czech Academy of Sciences Publication Activity Database

    Moučka, F.; Nezbeda, Ivo

    2009-01-01

    Roč. 74, č. 4 (2009), s. 559-563 ISSN 0010-0765 R&D Projects: GA AV ČR IAA400720802 Institutional research plan: CEZ:AV0Z40720504 Keywords : water–methanol mixtures * partial molar volume * polarizability Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.856, year: 2009

  15. Apparent molal volumes of symmetrical and asymmetrical isomers of tetrabutylammonium bromide in water at several temperatures

    International Nuclear Information System (INIS)

    Moreno, Nicolás; Malagón, Andrés; Buchner, Richard; Vargas, Edgar F.

    2014-01-01

    Highlights: • Apparent molal volumes of five isomers of Bu 4 NBr in water have been measured. • The structural effect of branched and linear chains is discussed. • The structural contributions to the ionic volume were calculated. -- Abstract: Apparent molal volumes of a series of differently substituted quaternary ammonium bromides, namely tetra-iso-butyl-, tetra-sec-butyl-, tetra-n-butyl-, di-n-butyl-di-sec-butyl- and di-n-butyl-di-iso-butylammonium bromide have been determined as a function of molal concentration at (298.15, 303.15 and 308.15) K. Partial molar volumes at infinite dilution and ionic molar volumes of these quaternary ammonium cations were determined. Structural volume contributions to the ionic molar volume were also calculated. The symmetric and asymmetric quaternary ammonium cations are “structure making” ions. The contribution of the branched butyl chains predominates over the linear butyl chains in the asymmetric cations

  16. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

    Science.gov (United States)

    Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A

    2014-03-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method. Published by Elsevier B.V.

  17. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods

    Science.gov (United States)

    Coes, Alissa L.; Paretti, Nicholas V.; Foreman, William T.; Iverson, Jana L.; Alvarez, David A.

    2014-01-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19–23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.

  18. Locations of Sampling Stations for Water Quality Monitoring in Water Distribution Networks.

    Science.gov (United States)

    Rathi, Shweta; Gupta, Rajesh

    2014-04-01

    Water quality is required to be monitored in the water distribution networks (WDNs) at salient locations to assure the safe quality of water supplied to the consumers. Such monitoring stations (MSs) provide warning against any accidental contaminations. Various objectives like demand coverage, time for detection, volume of water contaminated before detection, extent of contamination, expected population affected prior to detection, detection likelihood and others, have been independently or jointly considered in determining optimal number and location of MSs in WDNs. "Demand coverage" defined as the percentage of network demand monitored by a particular monitoring station is a simple measure to locate MSs. Several methods based on formulation of coverage matrix using pre-specified coverage criteria and optimization have been suggested. Coverage criteria is defined as some minimum percentage of total flow received at the monitoring stations that passed through any upstream node included then as covered node of the monitoring station. Number of monitoring stations increases with the increase in the value of coverage criteria. Thus, the design of monitoring station becomes subjective. A simple methodology is proposed herein which priority wise iteratively selects MSs to achieve targeted demand coverage. The proposed methodology provided the same number and location of MSs for illustrative network as an optimization method did. Further, the proposed method is simple and avoids subjectivity that could arise from the consideration of coverage criteria. The application of methodology is also shown on a WDN of Dharampeth zone (Nagpur city WDN in Maharashtra, India) having 285 nodes and 367 pipes.

  19. Monitoring Water Quality in the Future, Volume 3: Biomonitoring

    NARCIS (Netherlands)

    Zwart D de; ECO

    1995-01-01

    In general terms the problems with the existing water quality monitoring approach concern effective and efficient monitoring strategies. In 1993 the project "Monitoring water quality in the future" started in order to address these problems which will only increase in the future. In the framework of

  20. Comparison of filters for concentrating microbial indicators and pathogens in lake-water samples

    Science.gov (United States)

    Francy, Donna S.; Stelzer, Erin A.; Brady, Amie M.G.; Huitger, Carrie; Bushon, Rebecca N.; Ip, Hon S.; Ware, Michael W.; Villegas, Eric N.; Gallardo, Vincent; Lindquist, H.D. Alan

    2013-01-01

    Bacterial indicators are used to indicate increased health risk from pathogens and to make beach closure and advisory decisions; however, beaches are seldom monitored for the pathogens themselves. Studies of sources and types of pathogens at beaches are needed to improve estimates of swimming-associated health risks. It would be advantageous and cost-effective, especially for studies conducted on a regional scale, to use a method that can simultaneously filter and concentrate all classes of pathogens from the large volumes of water needed to detect pathogens. In seven recovery experiments, stock cultures of viruses and protozoa were seeded into 10-liter lake water samples, and concentrations of naturally occurring bacterial indicators were used to determine recoveries. For the five filtration methods tested, the highest median recoveries were as follows: glass wool for adenovirus (4.7%); NanoCeram for enterovirus (14.5%) and MS2 coliphage (84%); continuous-flow centrifugation (CFC) plus Virocap (CFC+ViroCap) for Escherichia coli (68.3%) and Cryptosporidium (54%); automatic ultrafiltration (UF) for norovirus GII (2.4%); and dead-end UF for Enterococcus faecalis (80.5%), avian influenza virus (0.02%), and Giardia (57%). In evaluating filter performance in terms of both recovery and variability, the automatic UF resulted in the highest recovery while maintaining low variability for all nine microorganisms. The automatic UF was used to demonstrate that filtration can be scaled up to field deployment and the collection of 200-liter lake water samples.

  1. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  2. Air-deployable oil spill sampling devices review phase 2 testing. Volume 1

    International Nuclear Information System (INIS)

    Hawke, L.; Dumouchel, A.; Fingas, M.; Brown, C.E.

    2007-01-01

    SAIC Canada tested air deployable oil sampling devices for the Emergencies Science and Technology Division of Environment Canada in order to determine the applicability and status of these devices. The 3 devices tested were: Canada's SABER (sampling autonomous buoy for evidence recovery), the United States' POPEIE (probe for oil pollution evidence in the environment); and, Sweden's SAR Floatation 2000. They were tested for buoyancy properties, drift behaviour and sampler sorbent pickup ratios. The SAR and SABER both had lesser draft and greater freeboard, while the POPEIE had much greater draft than freeboard. All 3 devices could be used for oil sample collection in that their drift characteristics would allow for the SABER and SAR devices to be placed upwind of the slick while the POPEIE device could be placed downwind of an oil spill. The sorbent testing revealed that Sefar sorbent and Spectra sorbent used in the 3 devices had negative pickup ratios for diesel but performance improved as oil viscosity increased. Both sorbents are inert and capable of collecting oil in sufficient volumes for consistent fingerprinting analysis. 10 refs., 8 tabs., 8 figs

  3. Microporous Carbon Spheres Solid Phase Membrane Tip Extraction for the Analysis of Nitrosamines in Water Samples

    International Nuclear Information System (INIS)

    Mohammed Salisu Musa; Wan Aini Wan Ibrahim

    2015-01-01

    A simple solid phase membrane tip extraction (SPMTE) utilizing microporous carbon spheres (MCS) was developed for the analysis of nitrosamines in aqueous samples. The method termed MCS-SPMTE was optimized for various important extraction parameters namely conditioning organic solvent, extraction time, effects of salt addition and pH change, desorption time, desorption solvent and sample volume. Under the optimized conditions, the method indicated good linearity in the range of 10-100 μg/ L with coefficients of determination, r 2 ≥0.9984. The method also demonstrated good reproducibility with % RSDs values ranging from 2.2 - 8.9 (n = 3). Limit of detection (LOD) and limit of quantification (LOQ) for the method ranged from 3.2 - 4.8 μg/ L and 10.9 - 15.9 μg/L respectively. Recoveries for both tap-water and lake water samples spiked at 10 μg/L were in the range of 83.2 - 107.5 %. (author)

  4. Magnetic hydrophilic-lipophilic balance sorbent for efficient extraction of chemical warfare agents from water samples.

    Science.gov (United States)

    Singh, Varoon; Purohit, Ajay Kumar; Chinthakindi, Sridhar; Goud D, Raghavender; Tak, Vijay; Pardasani, Deepak; Shrivastava, Anchal Roy; Dubey, Devendra Kumar

    2016-02-19

    Magnetic hydrophilic-lipophilic balance (MHLB) hybrid resin was prepared by precipitation polymerization using N-vinylpyrrolidone (PVP) and divinylbenzene (DVB) as monomers and Fe2O3 nanoparticles as magnetic material. These resins were successfully applied for the extraction of chemical warfare agents (CWAs) and their markers from water samples through magnetic dispersive solid-phase extraction (MDSPE). By varying the ratios of monomers, resin with desired hydrophilic-lipophilic balance was prepared for the extraction of CWAs and related esters of varying polarities. Amongst different composites Fe2O3 nanoparticles coated with 10% PVP+90% DVB exhibited the best recoveries varying between 70.32 and 97.67%. Parameters affecting the extraction efficiencies, such as extraction time, desorption time, nature and volume of desorption solvent, amount of extraction sorbent and the effect of salts on extraction were investigated. Under the optimized conditions, linearity was obtained in the range of 0.5-500 ng mL(-1) with correlation ranging from 0.9911-0.9980. Limits of detection and limits of quantification were 0.5-1.0 and 3.0-5.0 ng mL(-1) respectively with RSDs varying from 4.88-11.32% for markers of CWAs. Finally, the developed MDSPE method was employed for extraction of analytes from water samples of various sources and the OPCW proficiency test samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Use of graphene supported on aminopropyl silica for microextraction of parabens from water samples.

    Science.gov (United States)

    Fumes, Bruno Henrique; Lanças, Fernando Mauro

    2017-03-03

    This paper describes the synthesis, characterization and use of graphene supported on aminopropyl silica through covalent bonds (Si-G) as a sorbent for microextraction by packed sorbent (MEPS). Five parabens (methyl, ethyl, propyl, butyl and benzyl) present in water matrices were used as model compounds for this evaluation. The Si-G phase was compared to other sorbents used in MEPS (C18 and Strata™-X) and also with graphene supported on primary-secondary amine (PSA) silica, where Si-G showed better results. After this, the MEPS experimental parameters were optimized using the Si-G sorbent. The following variables were optimized through univariate experiments: pH (4,7 and 10), desorption solvent (ACN:MeOH (50:50), ACN:H 2 O (40:60), MeOH and ACN) and ionic strength (0, 10 and 20% of NaCl). A factorial design 2 6-2 was then employed to evaluate other variables, such as the sample volume, desorption volume, sampling cycles, wash cycles and desorption cycles, as well as the influence of NaCl% on the extraction performance. The optimized method achieved a linear range of 0.2-20μg/L for most parabens; weighted calibration models were employed during the linearity evaluation to reduce the absolute sum of the residue values and improve R 2 , which ranged from 0.9753 to 0.9849. The method's accuracy was 82.3-119.2%; precision, evaluated as the coefficient of variance for intraday and interday analysis, ranged from 1.5 to 19.2%. After evaluation of the figures of merit, the method was applied to the determination of parabens in water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Does the oscillation of the water volume of the reservoir influence in the same way in fish diet?

    Directory of Open Access Journals (Sweden)

    Jean Carlos Dantas de Oliveira

    2018-04-01

    Full Text Available Abstract Aim: To evaluate the fish feeding and to establish the preferential and secondary items of their diets, to determine the trophic guilds and the possible trophic structure variations in function of the water volume in Umari reservoir, Rio Grande do Norte, Brazilian semiarid. Methods The fish were captured quarterly between February and November of 2013, with gill nets with different meshes, being the apparatuses exposed at 5:00 p.m., with removal at 5:00 a.m. The food items were identified using stereoscopic and optical microscopes and evaluated through the Feeding Index (IAi, being the results of this procedure used in food similarity analysis. The volume of the items was orderly in NMDS and the time differences were tested in PERMANOVA. Results A total of 740 individuals belonging to 14 species were sampled, being analyzed a total of 258 stomachs and 8 intestines of 11 species. From the IAi values used in the trophic similarity analysis, the species were classified into five trophic guilds: detritivorous, insectivorous, malacophagous, carcinophagous and piscivorous. Conclusion The oscillation in the water volume of the reservoir did not influence the diet of the guild detritivorous, which shows that the variations in the volume of water of the reservoir do not influence in the same way the diet of the local ichthyofauna.

  7. Assessment of Sr-90 in water samples: precision and accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Nisti, Marcelo B.; Saueia, Cátia H.R.; Castilho, Bruna; Mazzilli, Barbara P., E-mail: mbnisti@ipen.br, E-mail: chsaueia@ipen.br, E-mail: bcastilho@ipen.br, E-mail: mazzilli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    The study of artificial radionuclides dispersion into the environment is very important to control the nuclear waste discharges, nuclear accidents and nuclear weapons testing. The accidents in Fukushima Daiichi Nuclear Power Plant and Chernobyl Nuclear Power Plant, released several radionuclides in the environment by aerial deposition and liquid discharge, with various level of radioactivity. The {sup 90}Sr was one of the elements released into the environment. The {sup 90}Sr is produced by nuclear fission with a physical half-life of 28.79 years with decay energy of 0.546 MeV. The aims of this study are to evaluate the precision and accuracy of three methodologies for the determination of {sup 90}Sr in water samples: Cerenkov, LSC direct method and with radiochemical separation. The performance of the methodologies was evaluated by using two scintillation counters (Quantulus and Hidex). The parameters Minimum Detectable Activity (MDA) and Figure Of Merit (FOM) were determined for each method, the precision and accuracy were checked using {sup 90}Sr standard solutions. (author)

  8. Verification of spectrophotometric method for nitrate analysis in water samples

    Science.gov (United States)

    Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu

    2017-12-01

    The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.

  9. Legionella saoudiensis sp. nov., isolated from a sewage water sample.

    Science.gov (United States)

    Bajrai, Leena Hussein; Azhar, Esam Ibraheem; Yasir, Muhammad; Jardot, Priscilla; Barrassi, Lina; Raoult, Didier; La Scola, Bernard; Pagnier, Isabelle

    2016-11-01

    A Gram-stain-negative, bacilli-shaped bacterial strain, LS-1T, was isolated from a sewage water sample collected in Jeddah, Saudi Arabia. The taxonomic position of strain LS-1T was investigated using a polyphasic taxonomic approach. Phylogenetic analysis based on 16S rRNA gene sequences and those of four other genes indicated that strain LS-1T belongs to the genus Legionella in the family Legionellaceae. Regarding the 16S rRNA gene, the most closely related species are Legionella rowbothamii LLAP-6T (98.6 %) and Legionella lytica L2T (98.5 %). The mip gene sequence of strain LS-1T showed 94 % sequence similarity with that of L. lytica L2T and 93 % similarity with that of L. rowbothamii LLAP-6T. Strain LS-1T grew optimally at a temperature of 32 °C on a buffered charcoal yeast extract (BCYE) agar plate in a 5 % CO2 atmosphere and had a flagellum. The combined phylogenetic, phenotypic and genomic sequence data suggest that strain LS-1T represents a novel species of the genus Legionella, for which the name Legionella saoudiensis sp. nov. is proposed. The type strain is LS-1T (=DSM 101682T=CSUR P2101T).

  10. Methods to maximise recovery of environmental DNA from water samples.

    Directory of Open Access Journals (Sweden)

    Rheyda Hinlo

    Full Text Available The environmental DNA (eDNA method is a detection technique that is rapidly gaining credibility as a sensitive tool useful in the surveillance and monitoring of invasive and threatened species. Because eDNA analysis often deals with small quantities of short and degraded DNA fragments, methods that maximize eDNA recovery are required to increase detectability. In this study, we performed experiments at different stages of the eDNA analysis to show which combinations of methods give the best recovery rate for eDNA. Using Oriental weatherloach (Misgurnus anguillicaudatus as a study species, we show that various combinations of DNA capture, preservation and extraction methods can significantly affect DNA yield. Filtration using cellulose nitrate filter paper preserved in ethanol or stored in a -20°C freezer and extracted with the Qiagen DNeasy kit outperformed other combinations in terms of cost and efficiency of DNA recovery. Our results support the recommendation to filter water samples within 24hours but if this is not possible, our results suggest that refrigeration may be a better option than freezing for short-term storage (i.e., 3-5 days. This information is useful in designing eDNA detection of low-density invasive or threatened species, where small variations in DNA recovery can signify the difference between detection success or failure.

  11. Assessment of Sr-90 in water samples: precision and accuracy

    International Nuclear Information System (INIS)

    Nisti, Marcelo B.; Saueia, Cátia H.R.; Castilho, Bruna; Mazzilli, Barbara P.

    2017-01-01

    The study of artificial radionuclides dispersion into the environment is very important to control the nuclear waste discharges, nuclear accidents and nuclear weapons testing. The accidents in Fukushima Daiichi Nuclear Power Plant and Chernobyl Nuclear Power Plant, released several radionuclides in the environment by aerial deposition and liquid discharge, with various level of radioactivity. The 90 Sr was one of the elements released into the environment. The 90 Sr is produced by nuclear fission with a physical half-life of 28.79 years with decay energy of 0.546 MeV. The aims of this study are to evaluate the precision and accuracy of three methodologies for the determination of 90 Sr in water samples: Cerenkov, LSC direct method and with radiochemical separation. The performance of the methodologies was evaluated by using two scintillation counters (Quantulus and Hidex). The parameters Minimum Detectable Activity (MDA) and Figure Of Merit (FOM) were determined for each method, the precision and accuracy were checked using 90 Sr standard solutions. (author)

  12. Increase in hippocampal water diffusion and volume during experimental pneumococcal meningitis is aggravated by bacteremia

    DEFF Research Database (Denmark)

    Holler, Jon G; Brandt, Christian T; Leib, Stephen L

    2014-01-01

    BACKGROUND: The hippocampus undergoes apoptosis in experimental pneumococcal meningitis leading to neurofunctional deficits in learning and memory function. The aim of the present study was 1) to investigate hippocampal apparent diffusion coefficient (ADC) and volume with MRI during the course...... and the volume and size of brain ventricles were positively correlated (Spearman Rank, p volume and the extent of apoptosis (p > 0.05). CONCLUSIONS: In experimental meningitis increase in volume and water diffusion of the hippocampus are significantly...... of experimental pneumococcal meningitis, 2) to explore the influence of accompanying bacteremia on hippocampal water distribution and volume, 3) and to correlate these findings to the extent of apoptosis in the hippocampus. METHODS: Experimental meningitis in rats was induced by intracisternal injection of live...

  13. Effects of water immersion to the neck on pulmonary circulation and tissue volume in man

    Science.gov (United States)

    Begin, R.; Epstein, M.; Sackner, M. A.; Levinson, R.; Dougherty, R.; Duncan, D.

    1976-01-01

    A rapid noninvasive breathing method is used to obtain serial measurements of the pulmonary capillary blood flow, diffusing capacity per unit of alveolar volume, combined pulmonary tissue plus capillary volume, functional residual capacity, and oxygen consumption in five normal subjects undergoing 6 h of sitting, 4 h of sitting while immersed to the neck in thermoneutral water, and 4 h of lying in thermoneutral water to the neck. The rebreathing method employed a test gas mixture containing 0.5% C2H2, 0.3% C(18)O, 10% He, 21% O2, and balance N2. It is shown that immersion to the neck in the seated posture results in significant increases in sodium excretion cardiac output, and diffusing capacity per unit of alveolar volume. The pulmonary tissue plus capillary volume did not change, demonstrating that the central vascular engorgement induced by water immersion is not accompanied by significant extravasation of fluid into the pulmonary interstitial space.

  14. chemical and microbiological assessment of surface water samples

    African Journals Online (AJOL)

    PROF EKWUEME

    concentrations and bacteriological content. Evaluation of the results ... and Aninri local government areas of Enugu state. Surface water ... surface water bodies are prone to impacts from ... Coal Measures (Akamigbo, 1987). The geologic map ...

  15. Propagation of errors from a null balance terahertz reflectometer to a sample's relative water content

    International Nuclear Information System (INIS)

    Hadjiloucas, S; Walker, G C; Bowen, J W; Zafiropoulos, A

    2009-01-01

    The THz water content index of a sample is defined and advantages in using such metric in estimating a sample's relative water content are discussed. The errors from reflectance measurements performed at two different THz frequencies using a quasi-optical null-balance reflectometer are propagated to the errors in estimating the sample water content index.

  16. Bacteriological analysis of well water samples in Sagamu | Idowu ...

    African Journals Online (AJOL)

    Majority of the population in semi-urban and urban areas of Nigeria depend on wells as their source of water supply. Due to increasing cases of water-borne diseases in recent times, this study was carried out to examine the microbial quality of well water in Sagamu, Nigeria as a way of safeguarding public health against ...

  17. Real-time analysis of water movement in plant sample

    International Nuclear Information System (INIS)

    Yokota, Harumi; Furukawa, Jun; Tanoi, Keitaro

    2000-01-01

    To know the effect of drought stress on two cultivars of cowpea, drought tolerant (DT) and drought sensitive (DS), and to estimate vanadium treatment on plant activity, we performed real time 18 F labeled water uptake measurement by PETIS. Fluoride-18 was produced by bombarding a cubic ice target with 50 MeV protons using TIARA AVF cyclotron. Then 18 F labeled water was applied to investigate water movement in a cowpea plant. Real time water uptake manner could be monitored by PETIS. After the analysis by PETIS, we also measured the distribution of 18 F in a whole plant by BAS. When a cowpea plant was treated with drought stress, there was a difference in water uptake manner between DT and DS cultivar. When a cowpea plant was treated with V for 20 hours before the water uptake experiment, the total amount of 18 F labeled water absorption was found to be drastically decreased. (author)

  18. Real-time analysis of water movement in plant sample

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Harumi; Furukawa, Jun; Tanoi, Keitaro [Graduate School, Tokyo Univ. (Japan)

    2000-07-01

    To know the effect of drought stress on two cultivars of cowpea, drought tolerant (DT) and drought sensitive (DS), and to estimate vanadium treatment on plant activity, we performed real time{sup 18}F labeled water uptake measurement by PETIS. Fluoride-18 was produced by bombarding a cubic ice target with 50 MeV protons using TIARA AVF cyclotron. Then {sup 18}F labeled water was applied to investigate water movement in a cowpea plant. Real time water uptake manner could be monitored by PETIS. After the analysis by PETIS, we also measured the distribution of {sup 18}F in a whole plant by BAS. When a cowpea plant was treated with drought stress, there was a difference in water uptake manner between DT and DS cultivar. When a cowpea plant was treated with V for 20 hours before the water uptake experiment, the total amount of {sup 18}F labeled water absorption was found to be drastically decreased. (author)

  19. Relationship between haemoglobin concentration and packed cell volume in cattle blood samples

    Directory of Open Access Journals (Sweden)

    Paa-Kobina Turkson

    2015-02-01

    Full Text Available A convention that has been adopted in medicine is to estimate haemoglobin (HB concentration as a third of packed cell volume (PCV or vice versa. The present research set out to determine whether a proportional relationship exists between PCV and Hb concentration in cattle blood samples, and to assess the validity of the convention of estimating Hb concentration as a third of PCV. A total of 440 cattle in Ghana from four breeds (Ndama, 110; West African Short Horn, 110; Zebu, 110 and Sanga, 110 were bled for haematological analysis, specifically packed cell volume, using the microhaematocrit technique and haemoglobin concentration using the cyanmethaemoglobin method. Means, standard deviations, standard errors of mean and 95% confidence intervals were calculated. Trendline analyses generated linear regression equations from scatterplots. For all the cattle, a significant and consistent relationship (r = 0.74 was found between Hb concentration and PCV (%. This was expressed as Hb concentration (g/dL = 0.28 PCV + 3.11. When the Hb concentration was estimated by calculating it as a third of PCV, the relationship was expressed in linear regression as Hb concentration (g/dL = 0.83 calculated Hb + 3.11. The difference in the means of determined (12.2 g/dL and calculated (10.9 g/dL Hb concentrations for all cattle was significant (p < 0.001, whereas the difference in the means of determined Hb and corrected calculated Hb was not significant. In conclusion, a simplified relationship of Hb (g/dL = (0.3 PCV + 3 may provide a better estimate of Hb concentration from the PCV of cattle.

  20. Development of analytical techniques for water and environmental samples (2)

    Energy Technology Data Exchange (ETDEWEB)

    Eum, Chul Hun; Jeon, Chi Wan; Jung, Kang Sup; Song, Kyung Sun; Kim, Sang Yeon [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The purpose of this study is to develop new analytical methods with good detection limit for toxic inorganic and organic compounds. The analyses of CN, organic acids, particulate materials in environmental samples have been done using several methods such as Ion Chromatography, SPE, SPME, GC/MS, GC/FID, SPLITT (split-flow thin cell fractionation) during the second year of this project. Advantage and disadvantage of several distillation method (by KS, JIS, EPA) for CN analysis in wastewater were investigated. As the results, we proposed new distillation apparatus for CN analysis, which was proved to be simpler, faster and to get better recovery than conventional apparatus. And ion chromatograph/pulsed amperometric detector (IC/PAD) system instead of colorimetry for CN detection was setup to solve matrix interference. And SPE(solid phase extraction) and SPME (solid phase micro extraction) as liquid-solid extraction technique were applied to the analysis of phenols in wastewater. Optimum experimental conditions and factors influencing analytical results were determined. From these results, It could be concluded that C{sub 18} cartridge and polystyrene-divinylbenzene disk in SPE method, polyacrylate fiber in SPME were proper solid phase adsorbent for phenol. Optimum conditions to analyze phenol derivatives simultaneously were established. Also, Continuous SPLITT (Split-flow thin cell) Fractionation (CSF) is a new preparative separation technique that is useful for fractionation of particulate and macromolecular materials. CSF is carried out in a thin ribbon-like channel equipped with two splitters at both inlet and outlet of the channel. In this work, we set up a new CSF system, and tested using polystyrene latex standard particles. And then we fractionated particles contained in air and underground water based on their sedimentation coefficients using CSF. (author). 27 refs., 13 tabs., 31 figs.

  1. Supercritical water oxidation data acquisition testing. Final report, Volume I

    International Nuclear Information System (INIS)

    1996-11-01

    This report discusses the phase one testing of a data acquisition system for a supercritical water waste oxidation system. The system is designed to destroy a wide range of organic materials in mixed wastes. The design and testing of the MODAR Oxidizer is discussed. An analysis of the optimized runs is included

  2. Evaluation of storage and filtration protocols for alpine/subalpine lake water quality samples

    Science.gov (United States)

    John L. Korfmacher; Robert C. Musselman

    2007-01-01

    Many government agencies and other organizations sample natural alpine and subalpine surface waters using varying protocols for sample storage and filtration. Simplification of protocols would be beneficial if it could be shown that sample quality is unaffected. In this study, samples collected from low ionic strength waters in alpine and subalpine lake inlets...

  3. Efficacy of thermal treatment and copper-silver ionization for controlling Legionella pneumophila in high-volume hot water plumbing systems in hospitals.

    Science.gov (United States)

    Mietzner, S; Schwille, R C; Farley, A; Wald, E R; Ge, J H; States, S J; Libert, T; Wadowsky, R M; Miuetzner, S

    1997-12-01

    Thermal treatment and copper-silver ionization are often used for controlling Legionella pneumophila in high-volume hospital plumbing systems, although the comparative efficacies of these measures in high-volume systems are unknown. Thermal treatment of a hot water circuit was accomplished by flushing hot water (> 60 degrees C) through distal fixtures for 10 minutes. Copper-silver ionization was conducted in three circuits by installing units into return lines immediately upstream from hot water tanks. Recovery rates of L. pneumophila were monitored by culturing swab samples from faucets. Concentrations of copper and silver in water samples were determined by atomic absorption spectrophotometry. Four heat-flush treatments failed to provide long-term control of L. pneumophila. In contrast, ionization treatment reduced the rate of recovery of L. pneumophila from 108 faucets from 72% to 2% within 1 month and maintained effective control for at least 22 months. Only three samples (1.9%) of hot water from faucets exceeded Environmental Protection Agency standards for silver, and none exceeded the standards for copper. Of 24 samples obtained from hot water tanks, 42% and 50% exceeded the silver and copper standards, respectively. Copper-silver ionization effectively controls L. pneumophila in high-volume plumbing systems and is superior to thermal treatment; however, high concentrations of copper and silver can accumulate at the bottom of hot water tanks.

  4. Water Remedial Investigation Report, Version 3.3. Volume 2

    Science.gov (United States)

    1989-07-01

    the Third Quarter FY 1987 water table contour map, S(Page 9 of 13) Water Level "KaU._ID LiaMAUan 26143 5175.9 26145 -999,9 27002 5095.3 27003 5098.0...26125 5146.9 26127 5164.6 26133 5147.0 26143 5175.9 4 26145 5140.9 ID 27001 5093.2 27002 5094.8 27003 51.08 -1 27004 B-105 20,43.7 27005 5094.2 27006...ML Po 1IM A- T .0 cO16 Folcm Iscale ’ 𔃾 IV*- C. [LA \\S Y4 6 It. ISO . 4:- 4~ 1A . 6 IAT sti ~~~~~ If*1 l H 44 - . C-99 0 S S 0 040 0 s HtHLm.01 0O

  5. Supercritical water oxidation data acquisition testing. Final report, Volume II

    International Nuclear Information System (INIS)

    1996-11-01

    Supercritical Water Oxidation (SCWO) technology holds great promise for treating mixed wastes, in an environmentally safe and efficient manner. In the spring of 1994 the US Department of Energy (DOE), Idaho Operations Office awarded Stone ampersand Webster Engineering Corporation, of Boston Massachusetts and its sub-contractor MODAR, Inc. of Natick Massachusetts a Supercritical Water Oxidation Data Acquisition Testing (SCWODAT) program. The SCWODAT program was contracted through a Cooperative Agreement that was co-funded by the US Department of Energy and the Strategic Environmental Research and Development Program. The SCWODAT testing scope outlined by the DOE in the original Cooperative Agreement and amendments thereto was initiated in June 1994 and successfully completed in December 1995. The SCWODAT program provided further information and operational data on the effectiveness of treating both simulated mixed waste and typical Navy hazardous waste using the MODAR SCWO technology

  6. Levels of Cadmium in Soil, Sediment and Water Samples from ...

    African Journals Online (AJOL)

    cce

    The agricultural application of phosphate fertilizers represents a direct ... The samples were put into clean plastic containers and sealed. The plastic ... dried samples were ground and homogenized in a porcelain mortar, sieved to 40 mesh size.

  7. Osmosis-induced water uptake by Eurobitum bituminized radioactive waste and pressure development in constant volume conditions

    International Nuclear Information System (INIS)

    Mariën, A.; Mokni, N.; Valcke, E.; Olivella, S.; Smets, S.; Li, X.

    2013-01-01

    Highlights: ► The water uptake by Eurobitum is studied to judge the safety of geological disposal. ► High pressures of up to 20 MPa are measured in constant volume water uptake tests. ► The morphology of leached Eurobitum samples is studied with μCT and ESEM. ► The observations are reproduced by an existing CHM formulation for Eurobitum. - Abstract: The chemo-hydro-mechanical (CHM) interaction between swelling Eurobitum radioactive bituminized waste (BW) and Boom Clay is investigated to assess the feasibility of geological disposal for the long-term management of this waste. These so-called compatibility studies include laboratory water uptake tests at Belgian Nuclear Research Center SCK-CEN, and the development of a coupled CHM formulation for Eurobitum by the International Center for Numerical Methods and Engineering (CIMNE, Polytechnical University of Cataluña, Spain). In the water uptake tests, the osmosis-induced swelling, pressure increase and NaNO 3 leaching of small cylindrical BW samples (diameter 38 mm, height 10 mm) is studied under constant total stress conditions and nearly constant volume conditions; the actual geological disposal conditions should be intermediate between these extremes. Two nearly constant volume tests were stopped after 1036 and 1555 days to characterize the morphology of the hydrated BW samples and to visualize the hydrated part with microfocus X-ray Computer Tomography (μCT) and Environmental Scanning Electron Microscopy (ESEM). In parallel, a coupled CHM formulation is developed that describes chemically and hydraulically coupled flow processes in porous materials with salt crystals, and that incorporates a porosity dependent membrane efficiency, permeability and diffusivity. When Eurobitum BW is hydrated in (nearly) constant volume conditions, the osmosis-induced water uptake results in an increasing pressure to values that can be (in theory) as high as 42.8 MPa, being the osmotic pressure of a saturated NaNO 3

  8. Tritium concentrations in environmental water and food samples collected around the vicinity of the PNPP-1

    International Nuclear Information System (INIS)

    Garcia, T.Y.; Enriquez, S.O.; Duran, E.B.

    1986-01-01

    The natural radioactivity levels of tritium in environmental samples collected around the vicinity and more distant environment of the first Philippine Nuclear Power Plant (PNPP-1) in Bataan were assessed. The samples analyzed consisted of water samples such as seawater, freshwater, drinking water, groundwater and rainwater; and food samples such as cereals, vegetables, fruits; meat, milk fish and crustaceans. Tritium concentrations in water samples were determined by distillation and liquid scintillation counting techniques. The food samples were analyzed for tissue-free water tritium by the freezing-drying method followed by liquid scintillation counting techniques. (Auth.) 13 refs

  9. Relationship Between LIBS Ablation and Pit Volume for Geologic Samples: Applications for the In Situ Absolute Geochronology

    Science.gov (United States)

    Devismes, Damien; Cohen, Barbara; Miller, J.-S.; Gillot, P.-Y.; Lefevre, J.-C.; Boukari, C.

    2014-01-01

    These first results demonstrate that LIBS spectra can be an interesting tool to estimate the ablated volume. When the ablated volume is bigger than 9.10(exp 6) cubic micrometers, this method has less than 10% of uncertainties. Far enough to be directly implemented in the KArLE experiment protocol. Nevertheless, depending on the samples and their mean grain size, the difficulty to have homogeneous spectra will increase with the ablated volume. Several K-Ar dating studies based on this approach will be implemented. After that, the results will be shown and discussed.

  10. A suspended-particle rosette multi-sampler for discrete biogeochemical sampling in low-particle-density waters

    Energy Technology Data Exchange (ETDEWEB)

    Breier, J. A.; Rauch, C. G.; McCartney, K.; Toner, B. M.; Fakra, S. C.; White, S. N.; German, C. R.

    2010-06-22

    To enable detailed investigations of early stage hydrothermal plume formation and abiotic and biotic plume processes we developed a new oceanographic tool. The Suspended Particulate Rosette sampling system has been designed to collect geochemical and microbial samples from the rising portion of deep-sea hydrothermal plumes. It can be deployed on a remotely operated vehicle for sampling rising plumes, on a wire-deployed water rosette for spatially discrete sampling of non-buoyant hydrothermal plumes, or on a fixed mooring in a hydrothermal vent field for time series sampling. It has performed successfully during both its first mooring deployment at the East Pacific Rise and its first remotely-operated vehicle deployments along the Mid-Atlantic Ridge. It is currently capable of rapidly filtering 24 discrete large-water-volume samples (30-100 L per sample) for suspended particles during a single deployment (e.g. >90 L per sample at 4-7 L per minute through 1 {mu}m pore diameter polycarbonate filters). The Suspended Particulate Rosette sampler has been designed with a long-term goal of seafloor observatory deployments, where it can be used to collect samples in response to tectonic or other events. It is compatible with in situ optical sensors, such as laser Raman or visible reflectance spectroscopy systems, enabling in situ particle analysis immediately after sample collection and before the particles alter or degrade.

  11. Evaluation Of Sachet Water Samples In Owerri Metropolis | Nwosu ...

    African Journals Online (AJOL)

    Other surveys revealed that 12 brands had fake manufactures' address, 2 brands had NAFDAC registration number while 3 brands had genuine manufacturers' address on them. It was discovered that the producers packaged the water from their water source without any form of treatment or analysis on it. Key words: ...

  12. Soluble and insoluble pollutants in fog and rime water samples

    Czech Academy of Sciences Publication Activity Database

    Fišák, Jaroslav; Stoyanova, V.; Chaloupecký, Pavel; Řezáčová, Daniela; Tsacheva, Ts.; Kupenova, T.; Marinov, M.

    2009-01-01

    Roč. 4, Sp. Iss. 2 (2009), S123-S130 ISSN 1801-5395 R&D Projects: GA ČR GA205/09/1918; GA AV ČR 1QS200420562 Institutional research plan: CEZ:AV0Z30420517 Keywords : fog water * rime water * pollutant concentration Subject RIV: DG - Athmosphere Sciences, Meteorology

  13. Integrated preservation and sample clean up procedures for studying water ingestion by recreational swimmers via urinary biomarker determination.

    Science.gov (United States)

    Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L

    2017-08-22

    The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.

  14. Determination of polycyclic aromatic hydrocarbons in drinking water samples by solid-phase nanoextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Huiyong; Campiglia, Andres D

    2008-11-01

    A novel alternative is presented for the extraction and preconcentration of polycyclic aromatic hydrocarbons (PAH) from water samples. The new approachwhich we have named solid-phase nanoextraction (SPNE)takes advantage of the strong affinity that exists between PAH and gold nanoparticles. Carefully optimization of experimental parameters has led to a high-performance liquid chromatography method with excellent analytical figures of merit. Its most striking feature correlates to the small volume of water sample (500 microL) for complete PAH analyses. The limits of detection ranged from 0.9 (anthracene) to 58 ng.L (-1) (fluorene). The relative standard deviations at medium calibration concentrations vary from 3.2 (acenaphthene) to 9.1% (naphthalene). The analytical recoveries from tap water samples of the six regulated PAH varied from 83.3 +/- 2.4 (benzo[ k]fluoranthene) to 95.7 +/- 4.1% (benzo[ g,h,i]perylene). The entire extraction procedure consumes less than 100 microL of organic solvents per sample, which makes it environmentally friendly. The small volume of extracting solution makes SPNE a relatively inexpensive extraction approach.

  15. Evaluation of an ambient air sampling system for tritium (as tritiated water vapor) using silica gel adsorbent columns

    International Nuclear Information System (INIS)

    Patton, G.W.; Cooper, A.T.; Tinker, M.R.

    1995-08-01

    Ambient air samples for tritium analysis (as the tritiated water vapor [HTO] content of atmospheric moisture) are collected for the Hanford Site Surface Environmental Surveillance Project (SESP) using the solid adsorbent silica gel. The silica gel has a moisture sensitive indicator which allows for visual observation of moisture movement through a column. Despite using an established method, some silica gel columns showed a complete change in the color indicator for summertime samples suggesting that breakthrough had occurred; thus a series of tests was conducted on the sampling system in an environmental chamber. The purpose of this study was to determine the maximum practical sampling volume and overall collection efficiency for water vapor collected on silica gel columns. Another purpose was to demonstrate the use of an impinger-based system to load water vapor onto silica gel columns to provide realistic analytical spikes and blanks for the Hanford Site SESP. Breakthrough volumes (V b ) were measured and the chromatographic efficiency (expressed as the number of theoretical plates [N]) was calculated for a range of environmental conditions. Tests involved visual observations of the change in the silica gel's color indicator as a moist air stream was drawn through the column, measurement of the amount of a tritium tracer retained and then recovered from the silica gel, and gravimetric analysis for silica gel columns exposed in the environmental chamber

  16. Sampling artifacts in measurement of elemental and organic carbon: Low-volume sampling in indoor and outdoor environments

    Science.gov (United States)

    Olson, David A.; Norris, Gary A.

    Experiments were completed to determine the extent of artifacts from sampling elemental carbon (EC) and organic carbon (OC) under sample conditions consistent with personal sampling. Two different types of experiments were completed; the first examined possible artifacts from oils used in personal environmental monitor (PEM) impactor plates, and the second examined artifacts from microenvironmental sampling using different sampling media combinations (quartz, Teflon, XAD denuder, and electrostatic precipitator). The effectiveness of front and backup filters was evaluated for most sampling configurations. Mean total carbon concentrations from sampling configurations using impactor oils were not statistically different from the control case (using a sharp cut cyclone). Three microenvironments were tested (kitchen, library, and ambient); carbon concentrations were highest in the kitchen using a front quartz filter (mean OC of 16.4 μg m -3). The lowest front quartz filter concentrations were measured in the library using XAD denuders (mean OC of 3.6 μg m -3). Denuder removal efficiencies (average of 82% for total carbon) were lower compared with previous ambient studies and may indicate that indoor sources influenced denuder efficiency during sample collection. The highest carbon concentrations from backup quartz filters were measured using the Teflon-quartz combination.

  17. Influence of bioassay volume, water column height, and octanol-water partition coefficient on the toxicity of pesticides to rainbow trout.

    Science.gov (United States)

    Altinok, Ilhan; Capkin, Erol; Boran, Halis

    2011-06-01

    Effects of water volume and water column height on toxicity of cypermethrin, carbaryl, dichlorvos, tetradifon, maneb, captan, carbosulfan endosulfan and HgCl₂ to juvenile rainbow trout (Oncorhynchus mykiss, 3.2 ± 0.7 g) were evaluated in different glass aquaria under static conditions. When fish were exposed to the chemical compounds in 23 cm water column height (25 L), their mortality ranged between 0% and 58%. At the same water volume, but lower water column height (9 cm), mortality of fish increased significantly and was in a range from 60% to 95%. At the same water column height, toxic effects of chemicals were significantly higher in 25 L water volume than that of 8.5 L, water except maneb which has lowest (-0.45) octanol-water partition coefficient value. Mortality rates ratio of 9 and 23 cm water column height ranged between 1.12 and 90 while mortality rates ratio of 9 and 25 L water volume ranged between 1.20 and 4.0. Because actual exposure concentrations were not affected by either water volume or water column height, we propose that increased pesticides' toxicity was related to an increase in bioassay volume, since more pesticide molecules were able to interact with or accumulate the fish. However, there seem to be no relationship between the effects of water volume, water column height and Kow value of chemicals with regard to toxicity in juvenile rainbow trout.

  18. Residual volume on land and when immersed in water: effect on percent body fat.

    Science.gov (United States)

    Demura, Shinichi; Yamaji, Shunsuke; Kitabayashi, Tamotsu

    2006-08-01

    There is a large residual volume (RV) error when assessing percent body fat by means of hydrostatic weighing. It has generally been measured before hydrostatic weighing. However, an individual's maximal exhalations on land and in the water may not be identical. The aims of this study were to compare residual volumes and vital capacities on land and when immersed to the neck in water, and to examine the influence of the measurement error on percent body fat. The participants were 20 healthy Japanese males and 20 healthy Japanese females. To assess the influence of the RV error on percent body fat in both conditions and to evaluate the cross-validity of the prediction equation, another 20 males and 20 females were measured using hydrostatic weighing. Residual volume was measured on land and in the water using a nitrogen wash-out technique based on an open-circuit approach. In water, residual volume was measured with the participant sitting on a chair while the whole body, except the head, was submerged . The trial-to-trial reliabilities of residual volume in both conditions were very good (intraclass correlation coefficient > 0.98). Although residual volume measured under the two conditions did not agree completely, they showed a high correlation (males: 0.880; females: 0.853; P body fat computed using residual volume measured in both conditions was very good for both sexes (males: r = 0.902; females: r = 0.869, P body fat: -3.4 to 2.2% for males; -6.3 to 4.4% for females). We conclude that if these errors are of no importance, residual volume measured on land can be used when assessing body composition.

  19. Chromatographic enrichment of isotopes in hydrogen and water samples on palladium

    International Nuclear Information System (INIS)

    Andreev, B.M.; Polevoi, A.S.; Perevezentsev, A.N.

    1987-01-01

    Data on the isotopic enrichment of hydrogen and water samples by chromatography on palladium have been analyzed. Experimental data on the effect of temperature, hydrogen flow, volume of the enriched fraction, and length of the chromatographic column on the degree of separation attainable in the column have been obtained. It has been shown that the maximum separation achievable (regardless of the type of the isotope mixture) at 273 K falls with increase of hydrogen flow and volume of the enriched gas fraction recoverable from the column. A separation degree of ∼ 1040 has been achieved for a mixture of protium and deuterium in a 10-mm wide and 0.6-m long chromatographic column packed with palladium black with a grain size of 0.2-0.5 mm at 273 K and a specific hydrogen flow of 1.22 mole/m 2 x sec. For a protium-tritium mixture a separation degree of ∼ 90 has been reached in a similar column at 273 K and a specific hydrogen flow of 0.4 mole/m 2 x sec

  20. Densities, molar volumes, and isobaric expansivities of (d-xylose+hydrochloric acid+water) systems

    International Nuclear Information System (INIS)

    Zhang Qiufen; Yan Zhenning; Wang Jianji; Zhang Hucheng

    2006-01-01

    Densities of (d-xylose+HCl+water) have been measured at temperature in the range (278.15 to 318.15) K as a function of concentration of both d-xylose and hydrochloric acid. The densities have been used to estimate the molar volumes and isobaric expansivity of the ternary solutions. The molar volumes of the ternary solutions vary linearly with mole fraction of d-xylose. The standard partial molar volumes V 2,φ - bar for d-xylose in aqueous solutions of molality (0.2, 0.4, 0.7, 1.1, 1.6, and 2.1) mol.kg -1 HCl have been determined. In the investigated temperature range, the relation: V 2,φ - bar =c 1 +c 2 {(T/K)-273.15} 1/2 , can be used to describe the temperature dependence of the standard partial molar volumes. These results have, in conjunction with the results obtained in water, been used to deduce the standard volumes of transfer, Δ t V - bar , of d-xylose from water to aqueous HCl solutions. An increase in the transfer volume of d-xylose with increasing HCl concentrations has been explained by the stronger interactions of H + with the hydrophilic groups of d-xylose

  1. Storm Water Sampling Data 11-16-17.

    Energy Technology Data Exchange (ETDEWEB)

    Holland, Robert C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-12-01

    In the California Industrial General Permit (IGP) 2014-0057-DWQ for storm water monitoring, effective July 1, 2015, there are 21 contaminants that have been assigned NAL (Numeric Action Level) values, both annual and instantaneous.

  2. Laser fluorosensor demonstration flights over Newfoundland coastal waters. Volume 1

    International Nuclear Information System (INIS)

    Brown, C.E.; Marois, R.

    2007-01-01

    The development and application of advanced oil spill remote sensing equipment was discussed with particular reference to 9 laser fluorosensor demonstration flights undertaken in March 2007 in the coastal waters of Newfoundland and Labrador. The Scanning Laser Environmental Airborne Fluorosensor (SLEAF) provides a fluorescent spectrum of oil to accurately identify even small amounts of fresh crudes equally well during full daylight conditions as at night. They allow for airborne detection, classification, surveillance monitoring of oil spills, as well as the exploration of marine petroleum resources. With the advent of powerful processors in modern computers, the classification capabilities of laser fluorosensors have significantly improved. Fluorescence information can be quickly transferred to response personnel on the ground or at sea to help plan effective oil spill countermeasures and to mitigate the effects of an oil spill in marine and coastal environments. Laser fluorosensors can successfully discriminate between oiled and un-oiled weeds and detect oil in water, snow, ice and beaches. The SLEAF flights were the third series undertaken over a period of 4 years in later winter weather conditions. The flights were focused over shipping lanes south of Newfoundland and Labrador around the local petroleum handling facilities. In addition to laser data, they provided georeferenced infrared, ultraviolet, colour video and digital still imagery. During the flights, SLEAF did not indicate much evidence of petroleum oil on the surface of the marine environment. None of the flights over 17 marine tankers, container vessels, supply vessels and tugs indicated any signs of oily discharge. 10 refs., 1 tab., 7 figs

  3. Mutagenicity of drinking water sampled from the Yangtze River and Hanshui River (Wuhan section) and correlations with water quality parameters.

    Science.gov (United States)

    Lv, Xuemin; Lu, Yi; Yang, Xiaoming; Dong, Xiaorong; Ma, Kunpeng; Xiao, Sanhua; Wang, Yazhou; Tang, Fei

    2015-03-31

    A total of 54 water samples were collected during three different hydrologic periods (level period, wet period, and dry period) from Plant A and Plant B (a source for Yangtze River and Hanshui River water, respectively), and several water parameters, such as chemical oxygen demand (COD), turbidity, and total organic carbon (TOC), were simultaneously analyzed. The mutagenicity of the water samples was evaluated using the Ames test with Salmonella typhimurium strains TA98 and TA100. According to the results, the organic compounds in the water were largely frame-shift mutagens, as positive results were found for most of the tests using TA98. All of the finished water samples exhibited stronger mutagenicity than the relative raw and distribution water samples, with water samples collected from Plant B presenting stronger mutagenic strength than those from Plant A. The finished water samples from Plant A displayed a seasonal-dependent variation. Water parameters including COD (r = 0.599, P = 0.009), TOC (r = 0.681, P = 0.02), UV254 (r = 0.711, P = 0.001), and total nitrogen (r = 0.570, P = 0.014) exhibited good correlations with mutagenicity (TA98), at 2.0 L/plate, which bolsters the argument of the importance of using mutagenicity as a new parameter to assess the quality of drinking water.

  4. Rapid determination of 226Ra in drinking water samples using dispersive liquid-liquid microextraction coupled with liquid scintillation counting

    International Nuclear Information System (INIS)

    Sadi, B.K.; Chunsheng Li; Kramer, G.H.; Johnson, C.L.; Queenie Ko; Lai, E.P.C.

    2011-01-01

    A new radioanalytical method was developed for rapid determination of 226 Ra in drinking water samples. The method is based on extraction and preconcentration of 226 Ra from a water sample to an organic solvent using a dispersive liquid-liquid microextraction (DLLME) technique followed by radiometric measurement using liquid scintillation counting. In DLLME for 226 Ra, a mixture of an organic extractant (toluene doped with dibenzo-21-crown-7 and 2-theonyltrifluoroacetone) and a disperser solvent (acetonitrile) is rapidly injected into the water sample resulting in the formation of an emulsion. Within the emulsion, 226 Ra reacts with dibenzo-21-crown-7 and 2-theonyltrifluoroacetone and partitions into the fine droplets of toluene. The water/toluene phases were separated by addition of acetonitrile as a de-emulsifier solvent. The toluene phase containing 226 Ra was then measured by liquid scintillation counting. Several parameters were studied to optimize the extraction efficiency of 226 Ra, including water immiscible organic solvent, disperser and de-emulsifier solvent type and their volume, chelating ligands for 226 Ra and their concentrations, inorganic salt additive and its concentration, and equilibrium pH. With the optimized DLLME conditions, the accuracy (expressed as relative bias, B r ) and method repeatability (expressed as relative precision, S B ) were determined by spiking 226 Ra at the maximum acceptable concentration level (0.5 Bq L -1 ) according to the Guidelines for Canadian Drinking Water Quality. Accuracy and repeatability were found to be less than -5% (B r ) and less than 6% (S B ), respectively, for both tap water and bottled natural spring water samples. The minimum detectable activity and sample turnaround time for determination of 226 Ra was 33 mBq L -1 and less than 3 h, respectively. The DLLME technique is selective for extraction of 226 Ra from its decay progenies. (author)

  5. Paper-Based Analytical Device for Zinc Ion Quantification in Water Samples with Power-Free Analyte Concentration

    Directory of Open Access Journals (Sweden)

    Hiroko Kudo

    2017-04-01

    Full Text Available Insufficient sensitivity is a general issue of colorimetric paper-based analytical devices (PADs for trace analyte detection, such as metal ions, in environmental water. This paper demonstrates the colorimetric detection of zinc ions (Zn2+ on a paper-based analytical device with an integrated analyte concentration system. Concentration of Zn2+ ions from an enlarged sample volume (1 mL has been achieved with the aid of a colorimetric Zn2+ indicator (Zincon electrostatically immobilized onto a filter paper substrate in combination with highly water-absorbent materials. Analyte concentration as well as sample pretreatment, including pH adjustment and interferent masking, has been elaborated. The resulting device enables colorimetric quantification of Zn2+ in environmental water samples (tap water, river water from a single sample application. The achieved detection limit of 0.53 μM is a significant improvement over that of a commercial colorimetric Zn2+ test paper (9.7 μM, demonstrating the efficiency of the developed analyte concentration system not requiring any equipment.

  6. Practical guidelines for small-volume additions of uninhibited water to waste storage tanks

    International Nuclear Information System (INIS)

    Hsu, T.C.; Wiersma, B.J.; Zapp, P.E.; Pike, J.A.

    1994-01-01

    Allowable volumes of uninhibited water additions to waste tanks are limited to volumes in which hydroxide and nitrite inhibitors reach required concentrations by diffusion from the bulk waste within five days. This diffusion process was modeled conservatively by Fick's second law of diffusion. The solution to the model was applied to all applicable conditions which exist in the waste tanks. Plant engineers adapted and incorporated the results into a practical working procedure for controlling and monitoring the addition of uninhibited water. Research, technical support, and field engineers worked together to produce an effective solution to a potential waste tank corrosion problem

  7. Adaptive Finite Volume Method for the Shallow Water Equations on Triangular Grids

    Directory of Open Access Journals (Sweden)

    Sudi Mungkasi

    2016-01-01

    Full Text Available This paper presents a numerical entropy production (NEP scheme for two-dimensional shallow water equations on unstructured triangular grids. We implement NEP as the error indicator for adaptive mesh refinement or coarsening in solving the shallow water equations using a finite volume method. Numerical simulations show that NEP is successful to be a refinement/coarsening indicator in the adaptive mesh finite volume method, as the method refines the mesh or grids around nonsmooth regions and coarsens them around smooth regions.

  8. Analysis of the high water wave volume for the Sava River near Zagreb

    Science.gov (United States)

    Trninic, Dusan

    2010-05-01

    The paper analyses volumes of the Sava River high water waves near Zagreb during the period: 1926-2008 (N = 83 years), which is needed for more efficient control of high and flood waters. The primary Sava flood control structures in the City of Zagreb are dikes built on both riverbanks, and the Odra Relief Canal with lateral spillway upstream from the City of Zagreb. Intensive morphological changes in the greater Sava area near Zagreb, and anthropological and climate variations and changes at the Sava catchment up to the Zagreb area require detailed analysis of the water wave characteristics. In one analysis, maximum annual volumes are calculated for high water waves with constant duration of: 10, 20, 30, 40, 50 and 60 days. Such calculations encompass total quantity of water (basic and surface runoff). The log Pearson III distribution is adapted for this series of maximum annual volumes. Based on the results obtained, the interrelations are established between the wave volume as function of duration and occurrence probability. In addition to the analysis of maximum volumes of constant duration, it is interesting to carry out the analyses of maximum volume in excess of the reference discharge since it is very important for the flood control. To determine the reference discharges, a discharge of specific duration is used from an average discharge duration curve. The adopted reference discharges have durations of 50, 40, 30, 20 and 10%. Like in the previous case, log Pearson III distribution is adapted to the maximum wave data series. For reference discharge Q = 604 m3/s (duration 10%), a linear trend is calculated of maximum annual volumes exceeding the reference discharge for the Sava near Zagreb during the analyzed period. The analysis results show a significant decrease trend. A similar analysis is carried out for the following three reference discharges: regular flood control measures at the Sava near Zagreb, which are proclaimed when the water level is 350 cm

  9. UMTRA Project water sampling and analysis plan: Canonsburg and Burrell, Pennsylvania

    International Nuclear Information System (INIS)

    1994-03-01

    Surface remedial action was completed at the Canonsburg and Burrell UMTRA Project sites in southwestern Pennsylvania in 1985 and 1987, respectively. Results of 1993 water sampling indicate ground water flow conditions and ground water quality at both sites have remained relatively consistent with time. Uranium concentrations in ground water continue to exceed the maximum concentration limit (MCL) at the Canonsburg site; no MCLs are exceeded in ground water at the Burrell site. Surface water quality shows no evidence of impact from the sites

  10. Large-volume injection of sample diluents not miscible with the mobile phase as an alternative approach in sample preparation for bioanalysis: an application for fenspiride bioequivalence.

    Science.gov (United States)

    Medvedovici, Andrei; Udrescu, Stefan; Albu, Florin; Tache, Florentin; David, Victor

    2011-09-01

    Liquid-liquid extraction of target compounds from biological matrices followed by the injection of a large volume from the organic layer into the chromatographic column operated under reversed-phase (RP) conditions would successfully combine the selectivity and the straightforward character of the procedure in order to enhance sensitivity, compared with the usual approach of involving solvent evaporation and residue re-dissolution. Large-volume injection of samples in diluents that are not miscible with the mobile phase was recently introduced in chromatographic practice. The risk of random errors produced during the manipulation of samples is also substantially reduced. A bioanalytical method designed for the bioequivalence of fenspiride containing pharmaceutical formulations was based on a sample preparation procedure involving extraction of the target analyte and the internal standard (trimetazidine) from alkalinized plasma samples in 1-octanol. A volume of 75 µl from the octanol layer was directly injected on a Zorbax SB C18 Rapid Resolution, 50 mm length × 4.6 mm internal diameter × 1.8 µm particle size column, with the RP separation being carried out under gradient elution conditions. Detection was made through positive ESI and MS/MS. Aspects related to method development and validation are discussed. The bioanalytical method was successfully applied to assess bioequivalence of a modified release pharmaceutical formulation containing 80 mg fenspiride hydrochloride during two different studies carried out as single-dose administration under fasting and fed conditions (four arms), and multiple doses administration, respectively. The quality attributes assigned to the bioanalytical method, as resulting from its application to the bioequivalence studies, are highlighted and fully demonstrate that sample preparation based on large-volume injection of immiscible diluents has an increased potential for application in bioanalysis.

  11. Hydrogen bonding interactions between ethylene glycol and water: density, excess molar volume, and spectral study

    Institute of Scientific and Technical Information of China (English)

    ZHANG JianBin; ZHANG PengYan; MA Kai; HAN Fang; CHEN GuoHua; WEI XiongHui

    2008-01-01

    Studies of the density and the excess molar volume of ethylene glycol (EG)-water mixtures were carried out to illustrate the hydrogen bonding interactions of EG with water at different temperatures, The re-sults suggest that a likely complex of 3 ethylene glycol molecules bonding with 4 water molecules in an ethylene glycol-water mixture (EGW) is formed at the maximal excess molar volume, which displays stronger absorption capabilities for SO2 when the concentration of SO2 reaches 400×106 (volume ratio) in the gas phase. Meanwhile, FTIR and UV spectra of EGWs were recorded at various EG concentra-tions to display the hydrogen bonding interactions of EG with water. The FTIR spectra show that the stretching vibrational band of hydroxyl in the EGWs shifts to a lower frequency and the bending vibra-tional band of water shifts to a higher frequency with increasing the EG concentration, respectively. Furthermore, the UV spectra show that the electron transferring band of the hydroxyl oxygen in EG shows red shift with increasing the EG concentration. The frequency shifts in FTIR spectra and the shifts of absorption bands in UV absorption spectra of EGWs are interpreted as the strong hydrogen bonding interactions of the hydrogen atoms in water with the hydroxyl oxygen atoms of EG.

  12. Hydrophobic hydration and the anomalous partial molar volumes in ethanol-water mixtures

    International Nuclear Information System (INIS)

    Tan, Ming-Liang; Te, Jerez; Cendagorta, Joseph R.; Miller, Benjamin T.; Brooks, Bernard R.; Ichiye, Toshiko

    2015-01-01

    The anomalous behavior in the partial molar volumes of ethanol-water mixtures at low concentrations of ethanol is studied using molecular dynamics simulations. Previous work indicates that the striking minimum in the partial molar volume of ethanol V E as a function of ethanol mole fraction X E is determined mainly by water-water interactions. These results were based on simulations that used one water model for the solute-water interactions but two different water models for the water-water interactions. This is confirmed here by using two more water models for the water-water interactions. Furthermore, the previous work indicates that the initial decrease is caused by association of the hydration shells of the hydrocarbon tails, and the minimum occurs at the concentration where all of the hydration shells are touching each other. Thus, the characteristics of the hydration of the tail that cause the decrease and the features of the water models that reproduce this type of hydration are also examined here. The results show that a single-site multipole water model with a charge distribution that mimics the large quadrupole and the p-orbital type electron density out of the molecular plane has “brittle” hydration with hydrogen bonds that break as the tails touch, which reproduces the deep minimum. However, water models with more typical site representations with partial charges lead to flexible hydration that tends to stay intact, which produces a shallow minimum. Thus, brittle hydration may play an essential role in hydrophobic association in water

  13. Water Remedial Investigation Report, Version 2.2. Volume 2

    Science.gov (United States)

    1989-03-01

    aaa-a M!a 1 ý1!lýlýl 1 l P a~~~ a m-- m m I" ; i4 s: - :a o at lmemot 4 em: W! me Ili -ý Ot At on emt:ý I! ISO -- -t~ -t utmmmm -t -t -t emt -- t eq...mm em mm m1 mmý IN eý 4 "! mý4 ! l 0 emo -- P p 40 ISO ------ a* do 2sgaI- w im 0;C 01O- - - #0’ - - . Is:111 ’t,"ý i 9: t a 4ýWt l "n4i Wt1":7 p...13) Water Level 26143 5175.9 26145 -999.9 27002 5095.3 27003 5098.0 27004 5093.9 27005 5094.1 27006 5094.2 27007 5095.2 27008 5095.3 27009 5095.7

  14. Total and inorganic arsenic in fish samples from Norwegian waters

    DEFF Research Database (Denmark)

    Julshamn, K.; Nilsen, B. M.; Frantzen, S.

    2012-01-01

    The contents of total arsenic and inorganic arsenic were determined in fillet samples of Northeast Arctic cod, herring, mackerel, Greenland halibut, tusk, saithe and Atlantic halibut. In total, 923 individual fish samples were analysed. The fish were mostly caught in the open sea off the coast......-assisted dissolution of the samples. The concentrations found for total arsenic varied greatly between fish species, and ranged from 0.3 to 110 mg kg–1 wet weight. For inorganic arsenic, the concentrations found were very low (...

  15. Effects of Contrast Agent and Outer Volume Saturation Bands on Water Suppression and Shimming of Hepatic Single-Volume Proton MR Spectroscopy at 3.0T

    Directory of Open Access Journals (Sweden)

    Li Xu

    2012-01-01

    Full Text Available Purpose. To determine whether administration of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA and whether placement of the outer volume saturation bands significantly affect shimming and water suppression on hepatic MR spectroscopic prescanning. Method. Region of interest (ROI of 2 cm × 2 cm × 2 cm was carefully positioned in the region of the middle portion of the right hepatic lobe. 32 patients were examined before and after administration of Gd-DTPA with and without outer-volume saturation bands. Linewidths (Full-Width Half-Maximum (FWHM and water suppression were obtained. A paired t-test for comparison of means was used. Results. (1 The group with the outer volume saturation bands demonstrated slightly better water suppression effect than the group without outer volume saturation bands before administration. (2 The group with the outer volume saturation bands demonstrated better water suppression effect than the group without outer volume saturation bands after administration. (3 Both shimming and water suppression effectswere decreased on enhanced MR spectroscopic prescanning (all P<0.05. Conclusions. Placement of the outer volume saturation bands is helpful to improve water suppression both before and after contrast agent administration. Gd-DTPA exerts a slightly adverse effect (a statistically significant but clinically unimportant on magnetic resonance spectroscopic prescanning at 3T.

  16. LTRM Water Quality Sampling Strata, UMRS La Grange Reach

    Data.gov (United States)

    Department of the Interior — The data set includes delineation of sampling strata for the six study reaches of the UMRR Program’s LTRM element. Separate strata coverages exist for each of the...

  17. Micro- and nano-volume samples by electrothermal, near-torch vaporization sample introduction using removable, interchangeable and portable rhenium coiled-filament assemblies and axially-viewed inductively coupled plasma-atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Badiei, Hamid R.; Lai, Bryant; Karanassios, Vassili

    2012-11-15

    An electrothermal, near-torch vaporization (NTV) sample introduction for micro- or nano-volume samples is described. Samples were pipetted onto coiled-filament assemblies that were purposely developed to be removable and interchangeable and were dried and vaporized into a small-volume vaporization chamber that clips onto any ICP torch with a ball joint. Interchangeable assemblies were also constructed to be small-size (e.g., less than 3 cm long with max diameter of 0.65 cm) and light-weight (1.4 g) so that they can be portable. Interchangeable assemblies with volume-capacities in three ranges (i.e., < 1 {mu}L, 1-10 {mu}L and 10-100 {mu}L) were fabricated and used. The horizontally-operated NTV sample introduction was interfaced to an axially-viewed ICP-AES (inductively coupled plasma-atomic emission spectrometry) system and NTV was optimized using ICP-AES and 8 elements (Pb, Cd, Zn, V, Ba, Mg, Be and Ca). Precision was 1.0-2.3% (peak height) and 1.1-2.4% (peak area). Detection limits (obtained using 5 {mu}L volumes) expressed in absolute-amounts ranged between 4 pg for Pb to 0.3 fg ({approx} 5 million atoms) for Ca. Detection limits expressed in concentration units (obtained using 100 {mu}L volumes of diluted, single-element standard solutions) were: 50 pg/mL for Pb; 10 pg/mL for Cd; 9 pg/mL for Zn; 1 pg/mL for V; 0.9 pg/mL for Ba; 0.5 pg/mL for Mg; 50 fg/mL for Be; and 3 fg/mL for Ca. Analytical capability and utility was demonstrated using the determination of Pb in pg/mL levels of diluted natural water Certified Reference Material (CRM) and the determination of Zn in 80 nL volumes of the liquid extracted from an individual vesicle. It is shown that portable and interchangeable assemblies with dried sample residues on them can be transported without analyte loss (for the concentrations tested), thus opening up the possibility for 'taking part of the lab to the sample' applications, such as testing for Cu concentration-compliance with the lead

  18. Bioimpedance measurement of body water correlates with measured volume balance in injured patients.

    Science.gov (United States)

    Rosemurgy, A S; Rodriguez, E; Hart, M B; Kurto, H Z; Albrink, M H

    1993-06-01

    Bioimpedance technology is being used increasingly to determine drug volume of distribution, body water status, and nutrition repletion. Its accuracy in patients experiencing large volume flux is not established. To address this, we undertook this prospective study in 54 consecutive seriously injured adults who had emergency celiotomy soon after arrival in the emergency department. Bioimpedance measurements were obtained in the emergency department before the patient was transported to the operating room, on completion of celiotomy, and 24 hours and 48 hours after celiotomy. Bioimpedance measurements of body water were compared with measured fluid balance. If insensible losses are subtracted from measured fluid balance, the percentage of body weight, which is body water determined by bioimpedance, closely follows fluid flux. This study supports the use of bioimpedance measurements in determining total body water even during periods of surgery, blood loss, and vigorous resuscitation.

  19. Alternative sorptive extraction method for gas chromatography determination of halogenated anisoles in water and wine samples

    International Nuclear Information System (INIS)

    Montes, R.; Rodriguez, I.; Rubi, E.; Bollain, M.H.; Cela, R.

    2007-01-01

    An alternative sorptive microextraction method for the determination of five halogenated anisoles in water and wine matrices is proposed. Analytes were concentrated in an inexpensive and disposable piece of bulk polydimethylsiloxane (PDMS), desorbed with a small volume of organic solvent, and determined by gas chromatography with electron-capture detection (GC-ECD) or tandem mass spectrometry (GC-MS/MS). The influence of several factors on the efficiency of extraction and desorption steps was investigated in detail and the observed behaviour justified on the basis of thermodynamics and kinetics of the solid-phase microextraction technique. Under optimised conditions, analytes were first extracted in the headspace (HS) mode, at room temperature, for 2.5 h and then desorbed with 1 mL of n-pentane. This extract was further evaporated to 50 μL. The overall extraction yield of the procedure ranged from 40 to 55% and the limits of quantification remained between 0.5 and 20 ng L -1 , depending on the compound considered and the detection technique. Precision and linearity of the method were excellent for all species with both GC-ECD and GC-MS/MS detection. Matrix effects were evaluated with different water and wine samples; moreover, the suitability of the PDMS sorbent for storage of analytes, under different conditions, was demonstrated

  20. Alternative sorptive extraction method for gas chromatography determination of halogenated anisoles in water and wine samples

    Energy Technology Data Exchange (ETDEWEB)

    Montes, R. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain); Rodriguez, I. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain)], E-mail: qnisaac@usc.es; Rubi, E.; Bollain, M.H.; Cela, R. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain)

    2007-09-05

    An alternative sorptive microextraction method for the determination of five halogenated anisoles in water and wine matrices is proposed. Analytes were concentrated in an inexpensive and disposable piece of bulk polydimethylsiloxane (PDMS), desorbed with a small volume of organic solvent, and determined by gas chromatography with electron-capture detection (GC-ECD) or tandem mass spectrometry (GC-MS/MS). The influence of several factors on the efficiency of extraction and desorption steps was investigated in detail and the observed behaviour justified on the basis of thermodynamics and kinetics of the solid-phase microextraction technique. Under optimised conditions, analytes were first extracted in the headspace (HS) mode, at room temperature, for 2.5 h and then desorbed with 1 mL of n-pentane. This extract was further evaporated to 50 {mu}L. The overall extraction yield of the procedure ranged from 40 to 55% and the limits of quantification remained between 0.5 and 20 ng L{sup -1}, depending on the compound considered and the detection technique. Precision and linearity of the method were excellent for all species with both GC-ECD and GC-MS/MS detection. Matrix effects were evaluated with different water and wine samples; moreover, the suitability of the PDMS sorbent for storage of analytes, under different conditions, was demonstrated.

  1. Difficulties in obtaining representative samples for compliance with the Ballast Water Management Convention

    Digital Repository Service at National Institute of Oceanography (India)

    Carney, K.J; Basurko, O.C; Pazouki, K.; Marsham, S.; Delany, J; Desai, D.V.; Anil, A.C; Mesbahi, E.

    water, the shape, size and number of ballast tanks and the heterogeneous distribution of organisms within tanks. These factors hinder efforts to obtain samples that truly represent the total ballast water onboard a vessel. A known cell density...

  2. Beryllium-10 concentrations in water samples of high northern latitudes

    Energy Technology Data Exchange (ETDEWEB)

    Strobl, C.; Eisenhauer, A.; Schulz, V.; Baumann, S.; Mangini, A. [Heidelberger Akademie der Wissenschaften, Heildelberg (Germany); Kubik, P.W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    {sup 10}Be concentrations in the water column of high northern latitudes were not available so far. We present different {sup 10}Be profiles from the Norwegian-Greenland Sea, the Arctic Ocean, and the Laptev Sea. (author) 3 fig., 3 refs.

  3. Identifying potential surface water sampling sites for emerging ...

    African Journals Online (AJOL)

    Emerging chemical pollutants (ECPs) are defined as new chemicals which do not have a regulatory status, but which may have an adverse effect on human health and the environment. The occurrence and concentrations of ECPs in South African water bodies are largely unknown, so monitoring is required in order to ...

  4. Sample container and storage for paclobutrazol monitoring in irrigation water

    Science.gov (United States)

    Paclobutrazol is a plant growth retardant commonly used on greenhouse crops. Residues from paclobutrazol applications can accumulate in recirculated irrigation water. Given that paclobutrazol has a long half-life and potential biological activity in parts per billion concentrations, it would be de...

  5. Microextraction Techniques Coupled to Liquid Chromatography with Mass Spectrometry for the Determination of Organic Micropollutants in Environmental Water Samples

    Directory of Open Access Journals (Sweden)

    Mª Esther Torres Padrón

    2014-07-01

    Full Text Available Until recently, sample preparation was carried out using traditional techniques, such as liquid–liquid extraction (LLE, that use large volumes of organic solvents. Solid-phase extraction (SPE uses much less solvent than LLE, although the volume can still be significant. These preparation methods are expensive, time-consuming and environmentally unfriendly. Recently, a great effort has been made to develop new analytical methodologies able to perform direct analyses using miniaturised equipment, thereby achieving high enrichment factors, minimising solvent consumption and reducing waste. These microextraction techniques improve the performance during sample preparation, particularly in complex water environmental samples, such as wastewaters, surface and ground waters, tap waters, sea and river waters. Liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS and time-of-flight mass spectrometric (TOF/MS techniques can be used when analysing a broad range of organic micropollutants. Before separating and detecting these compounds in environmental samples, the target analytes must be extracted and pre-concentrated to make them detectable. In this work, we review the most recent applications of microextraction preparation techniques in different water environmental matrices to determine organic micropollutants: solid-phase microextraction SPME, in-tube solid-phase microextraction (IT-SPME, stir bar sorptive extraction (SBSE and liquid-phase microextraction (LPME. Several groups of compounds are considered organic micropollutants because these are being released continuously into the environment. Many of these compounds are considered emerging contaminants. These analytes are generally compounds that are not covered by the existing regulations and are now detected more frequently in different environmental compartments. Pharmaceuticals, surfactants, personal care products and other chemicals are considered micropollutants. These

  6. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, F; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...

  7. Ionic Liquid Dispersive Liquid-Liquid Microextraction Method for the Determination of Irinotecan, an Anticancer Drug, in Water and Urine Samples Using UV-Vis Spectrophotometry.

    Science.gov (United States)

    Uysal, Deniz; Karadaş, Cennet; Kara, Derya

    2017-05-01

    A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.

  8. UMTRA Project water sampling and analysis plan, Grand Junction, Colorado. Revision 1, Version 6

    International Nuclear Information System (INIS)

    1995-09-01

    This water sampling and analysis plan describes the planned, routine ground water sampling activities at the Grand Junction US DOE Uranium Mill Tailings Remedial Action (UMTRA) Project site (GRJ-01) in Grand Junction, Colorado, and at the Cheney Disposal Site (GRJ-03) near Grand Junction. The plan identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequencies for the routine monitoring stations at the sites. Regulatory basis is in the US EPA regulations in 40 CFR Part 192 (1994) and EPA ground water quality standards of 1995 (60 FR 2854). This plan summarizes results of past water sampling activities, details water sampling activities planned for the next 2 years, and projects sampling activities for the next 5 years

  9. SEAMIST trademark soil sampling for tritiated water: First year's results

    International Nuclear Information System (INIS)

    Mallon, B.; Martins, S.A.; Houpis, J.L.; Lowry, W.; Cremer, C.D.

    1992-01-01

    SEAMIST trademark is a recently developed sampling system that enables one to measure various soil parameters by means of an inverted, removable, impermeable membrane tube inserted in a borehole. This membrane tube can have various measuring devices installed on it, such as gas ports, adsorbent pads, and electrical sensors. These membrane tubes are made of a laminated polymer. The Lawrence Livermore National Laboratory in Livermore, California, has installed two of these systems to monitor tritium in soil resulting from a leak in an underground storage tank. One tube is equipped with gas ports to sample soil vapor and the other with adsorbent pads to sample soil moisture. Borehole stability was maintained using either sand-filled or air-inflated tubes. Both system implementations yielded concentrations or activities that compared well with the measured concentrations of tritium in the soil taken during borehole construction. In addition, an analysis of the data suggest that both systems prevented the vertical migration of tritium in the boreholes. Also, a neutron probe was successfully used in a blank membrane inserted in one of the boreholes to monitor the moisture in the soil without exposing the probe to the tritium. The neutron log showed excellent agreement with the soil moisture content measured in soil samples taken during borehole construction. This paper describes the two SEAMIST trademark systems used and presents sampling results and comparisons

  10. UMTRA Project water sampling and analysis plan, Gunnison, Colorado: Revision 1

    International Nuclear Information System (INIS)

    1994-11-01

    This water sampling and analysis plan summarizes the results of previous water sampling activities and the plan for future water sampling activities, in accordance with the Guidance Document for Preparing Sampling and Analysis Plans for UMTRA Sites. A buffer zone monitoring plan for the Dos Rios Subdivision is included as an appendix. The buffer zone monitoring plan was developed to ensure continued protection to the public from residual contamination. The buffer zone is beyond the area depicted as contaminated ground water due to former milling operations. Surface remedial action at the Gunnison Uranium Mill Tailings Remedial Action Project site began in 1992; completion is expected in 1995. Ground water and surface water will be sampled semiannually at the Gunnison processing site and disposal site. Results of previous water sampling at the Gunnison processing site indicate that ground water in the alluvium is contaminated by the former uranium processing activities. Background ground water conditions have been established in the uppermost aquifer at the Gunnison disposal site. The monitor well locations provide a representative distribution of sampling points to characterize ground water quality and ground water flow conditions in the vicinity of the sites. The list of analytes has been modified with time to reflect constituents that are related to uranium processing activities and the parameters needed for geochemical evaluation

  11. Total and inorganic arsenic in fish samples from Norwegian waters.

    Science.gov (United States)

    Julshamn, Kaare; Nilsen, Bente M; Frantzen, Sylvia; Valdersnes, Stig; Maage, Amund; Nedreaas, Kjell; Sloth, Jens J

    2012-01-01

    The contents of total arsenic and inorganic arsenic were determined in fillet samples of Northeast Artic cod, herring, mackerel, Greenland halibut, tusk, saithe and Atlantic halibut. In total, 923 individual fish samples were analysed. The fish were mostly caught in the open sea off the coast of Norway, from 40 positions. The determination of total arsenic was carried out by inductively coupled plasma mass spectrometry following microwave-assisted wet digestion. The determination of inorganic arsenic was carried out by high-performance liquid chromatography-ICP-MS following microwave-assisted dissolution of the samples. The concentrations found for total arsenic varied greatly between fish species, and ranged from 0.3 to 110 mg kg(-1) wet weight. For inorganic arsenic, the concentrations found were very low (fish used in the recent EFSA opinion on arsenic in food.

  12. Porphyrin-based magnetic nanocomposites for efficient extraction of polycyclic aromatic hydrocarbons from water samples.

    Science.gov (United States)

    Yu, Jing; Zhu, Shukui; Pang, Liling; Chen, Pin; Zhu, Gang-Tian

    2018-03-09

    Stable and reusable porphyrin-based magnetic nanocomposites were successfully synthesized for efficient extraction of polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. Meso-Tetra (4-carboxyphenyl) porphyrin (TCPP), a kind of porphyrin, can connect the copolymer after amidation and was linked to Fe 3 O 4 @SiO 2 magnetic nanospheres via cross-coupling. Several characteristic techniques such as field emission scanning electron microscopy, transmission electron microscopy, X-ray diffraction, Fourier transform infrared spectrometry, vibrating sample magnetometry and a tensiometer were used to characterize the as-synthesized materials. The structure of the copolymer was similar to that of graphene, possessing sp 2 -conjugated carbon rings, but with an appropriate amount of delocalized π-electrons giving rise to the higher extraction efficiency for heavy PAHs without sacrificing the performance in the extraction of light PAHs. Six extraction parameters, including the TCPP:Fe 3 O 4 @SiO 2 (m:m) ratio, the amount of adsorbents, the type of desorption solvent, the desorption solvent volume, the adsorption time and the desorption time, were investigated. After the optimization of extraction conditions, a comparison of the extraction efficiency of Fe 3 O 4 @SiO 2 -TCPP and Fe 3 O 4 @SiO 2 @GO was carried out. The adsorption mechanism of TCPP to PAHs was studied by first-principles density functional theory (DFT) calculations. Combining experimental and calculated results, it was shown that the π-π stacking interaction was the main adsorption mechanism of TCPP for PAHs and that the amount of delocalized π-electrons plays an important role in the elution process. Under the optimal conditions, Fe 3 O 4 @SiO 2 -porphyrin showed good precision in intra-day (<8.9%) and inter-day (<13.0%) detection, low method detection limits (2-10 ng L -1 ), and wide linearity (10-10000 ng L -1 ). The method was applied to simultaneous analysis of 15 PAHs with

  13. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, Flemming; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...... of albumin in arterial and venous blood in seven healthy subjects before and during insulin-induced hypoglycaemia. In both vascular sites blood 51Cr content and the haematocrit increased, plasma volume and intravascular albumin content decreased and the transcapillary escape rate of albumin increased during...

  14. On-line micro-volume introduction system developed for lower density than water extraction solvent and dispersive liquid–liquid microextraction coupled with flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Anthemidis, Aristidis N.; Mitani, Constantina; Balkatzopoulou, Paschalia; Tzanavaras, Paraskevas D.

    2012-01-01

    Highlights: ► A dispersive liquid–liquid micro extraction method for lead and copper determination. ► A micro-volume transportation system for extractant solvent lighter than water. ► Analysis of natural water samples. - Abstract: A simple and fast preconcentration/separation dispersive liquid–liquid micro extraction (DLLME) method for metal determination based on the use of extraction solvent with lower density than water has been developed. For this purpose a novel micro-volume introduction system was developed enabling the on-line injection of the organic solvent into flame atomic absorption spectrometry (FAAS). The effectiveness and efficiency of the proposed system were demonstrated for lead and copper preconcentration in environmental water samples using di-isobutyl ketone (DBIK) as extraction solvent. Under the optimum conditions the enhancement factor for lead and copper was 187 and 310 respectively. For a sample volume of 10 mL, the detection limit (3 s) and the relative standard deviation were 1.2 μg L −1 and 3.3% for lead and 0.12 μg L −1 and 2.9% for copper respectively. The developed method was evaluated by analyzing certified reference material and it was applied successfully to the analysis of environmental water samples.

  15. Survey of fish impingement at power plants in the United States. Volume II. Inland waters

    International Nuclear Information System (INIS)

    Freeman, R.F. III; Sharma, R.K.

    1977-03-01

    Impingement of fish at cooling-water intakes of 33 power plants located on inland waters other than the Great Lakes has been surveyed and data are presented. Descriptions of site, plant, and intake design and operation are provided. Reports in this volume summarize impingement data for individual plants in tabular and histogram formats. Information was available from differing sources such as the utilities themselves, public documents, regulatory agencies, and others. Thus, the extent of detail in the reports varies greatly from plant to plant. Histogram preparation involved an extrapolation procedure that has inadequacies. The reader is cautioned in the use of information presented in this volume to determine intake-design acceptability or intensity of impacts on ecosystems. No conclusions are presented herein; data comparisons are made in Volume IV

  16. Path Complexity in Virtual Water Maze Navigation: Differential Associations with Age, Sex, and Regional Brain Volume.

    Science.gov (United States)

    Daugherty, Ana M; Yuan, Peng; Dahle, Cheryl L; Bender, Andrew R; Yang, Yiqin; Raz, Naftali

    2015-09-01

    Studies of human navigation in virtual maze environments have consistently linked advanced age with greater distance traveled between the start and the goal and longer duration of the search. Observations of search path geometry suggest that routes taken by older adults may be unnecessarily complex and that excessive path complexity may be an indicator of cognitive difficulties experienced by older navigators. In a sample of healthy adults, we quantify search path complexity in a virtual Morris water maze with a novel method based on fractal dimensionality. In a two-level hierarchical linear model, we estimated improvement in navigation performance across trials by a decline in route length, shortening of search time, and reduction in fractal dimensionality of the path. While replicating commonly reported age and sex differences in time and distance indices, a reduction in fractal dimension of the path accounted for improvement across trials, independent of age or sex. The volumes of brain regions associated with the establishment of cognitive maps (parahippocampal gyrus and hippocampus) were related to path dimensionality, but not to the total distance and time. Thus, fractal dimensionality of a navigational path may present a useful complementary method of quantifying performance in navigation. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  17. Journal of Sustainable Development of Energy, Water and Environment Systems – Volume IV

    Directory of Open Access Journals (Sweden)

    Neven Duić

    2016-12-01

    In total 32 manuscripts were published in Volume IV, all of them reviewed by at least two reviewers. The Journal of Sustainable Development of Energy, Water and Environment Systems would like to thank reviewers for their contribution to the quality of the published manuscripts.

  18. The effect of water saturation deficit on the volume of intercellular space in laeves

    Directory of Open Access Journals (Sweden)

    J. Czerski

    2015-01-01

    Full Text Available The volume of intercellular spaces in leaves at various stages of water saturation was determined by method of Czerski (1964, 1968. The investigation were performed with the following plant species: Vicia faba L., Nicotiana tabacum L. var. rustica, Solarium tuberosum L. var. Flisak, Helichrysum bracteatum Wild., Bmssica napus L. var. oleifera, Beta vulgaris L. var. saccharifera.

  19. Imaging water velocity and volume fraction distributions in water continuous multiphase flows using inductive flow tomography and electrical resistance tomography

    International Nuclear Information System (INIS)

    Meng, Yiqing; Lucas, Gary P

    2017-01-01

    This paper presents the design and implementation of an inductive flow tomography (IFT) system, employing a multi-electrode electromagnetic flow meter (EMFM) and novel reconstruction techniques, for measuring the local water velocity distribution in water continuous single and multiphase flows. A series of experiments were carried out in vertical-upward and upward-inclined single phase water flows and ‘water continuous’ gas–water and oil–gas–water flows in which the velocity profiles ranged from axisymmetric (single phase and vertical-upward multiphase flows) to highly asymmetric (upward-inclined multiphase flows). Using potential difference measurements obtained from the electrode array of the EMFM, local axial velocity distributions of the continuous water phase were reconstructed using two different IFT reconstruction algorithms denoted RT#1, which assumes that the overall water velocity profile comprises the sum of a series of polynomial velocity components, and RT#2, which is similar to RT#1 but which assumes that the zero’th order velocity component may be replaced by an axisymmetric ‘power law’ velocity distribution. During each experiment, measurement of the local water volume fraction distribution was also made using the well-established technique of electrical resistance tomography (ERT). By integrating the product of the local axial water velocity and the local water volume fraction in the cross section an estimate of the water volumetric flow rate was made which was compared with a reference measurement of the water volumetric flow rate. In vertical upward flows RT#2 was found to give rise to water velocity profiles which are consistent with the previous literature although the profiles obtained in the multiphase flows had relatively higher central velocity peaks than was observed for the single phase profiles. This observation was almost certainly a result of the transfer of axial momentum from the less dense dispersed phases to the

  20. Imaging water velocity and volume fraction distributions in water continuous multiphase flows using inductive flow tomography and electrical resistance tomography

    Science.gov (United States)

    Meng, Yiqing; Lucas, Gary P.

    2017-05-01

    This paper presents the design and implementation of an inductive flow tomography (IFT) system, employing a multi-electrode electromagnetic flow meter (EMFM) and novel reconstruction techniques, for measuring the local water velocity distribution in water continuous single and multiphase flows. A series of experiments were carried out in vertical-upward and upward-inclined single phase water flows and ‘water continuous’ gas-water and oil-gas-water flows in which the velocity profiles ranged from axisymmetric (single phase and vertical-upward multiphase flows) to highly asymmetric (upward-inclined multiphase flows). Using potential difference measurements obtained from the electrode array of the EMFM, local axial velocity distributions of the continuous water phase were reconstructed using two different IFT reconstruction algorithms denoted RT#1, which assumes that the overall water velocity profile comprises the sum of a series of polynomial velocity components, and RT#2, which is similar to RT#1 but which assumes that the zero’th order velocity component may be replaced by an axisymmetric ‘power law’ velocity distribution. During each experiment, measurement of the local water volume fraction distribution was also made using the well-established technique of electrical resistance tomography (ERT). By integrating the product of the local axial water velocity and the local water volume fraction in the cross section an estimate of the water volumetric flow rate was made which was compared with a reference measurement of the water volumetric flow rate. In vertical upward flows RT#2 was found to give rise to water velocity profiles which are consistent with the previous literature although the profiles obtained in the multiphase flows had relatively higher central velocity peaks than was observed for the single phase profiles. This observation was almost certainly a result of the transfer of axial momentum from the less dense dispersed phases to the water

  1. Effect of Fiber Volume Fraction and Water Absorption toward Bending Strength of Coconut Filters/ Polyester Composite

    Directory of Open Access Journals (Sweden)

    I Putu Lokantara

    2012-11-01

    Full Text Available The variation of fibre volume and the duration of water soaking take influence on the mechanical properties of composite. This research aim is to know the influence of fraction volume fibre and soaking duration on the mineral watertoward the tensile strength and flexural of polyester-coconut-tapis composite. This research used coconut-tapis fibre which is cut 1 cm in length with 0%, 5%, 7,5%, and 10% fiber volume fraction, unsaturated-polyester (UPRs matrix resin type Yucalac 157 BQTN-EX, and MEKPO hardener. The flexure specimen are made by press hand lay-up method and cut according ASTM D790-03 for the flexure test. The result of flexure test shows that the duration of soaking and the fiber volume fraction give a significant effect on the flexural strength of composite. The highest strength are reached by composite with 10% fibre volume on 48 hour soaking time equal to 41.994 MPa. The flexure modulus happenend shows increasing until 24 hour soaking time. The highest modulus are reached by composite with 10% fibre volume equal to 7.114 GPa while the lowest are reached by composite with 0% fibre volume equal to 3,023 GPa.

  2. Determination of Phenols in Water Samples using a Supported ...

    African Journals Online (AJOL)

    NJD

    This was achieved by pH adjustments in the sample and acceptor phases. The method was ... during wastewater treatment, since chlorine is added as a disinfectant. ... they give a high degree of selectivity and clean-up, use little or no organic ...

  3. A nanoparticle-based solid-phase extraction procedure followed by spectrofluorimetry to determine carbaryl in different water samples

    Energy Technology Data Exchange (ETDEWEB)

    Tabrizi, Ahad Bavili, E-mail: a.bavili@tbzmed.ac.ir, E-mail: abavilitabrizia@gmail.com [Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz (Iran, Islamic Republic of); Rashidi, Mohammad Reza [Research Center for Pharmaceutical Nanotechnology, Tabriz University of Medical Sciences, Tabriz, (Iran, Islamic Republic of); Ostadi, Hadi [Department of Chemistry, Payam-e-noor University, Ardabil Branch, Ardabil (Iran, Islamic Republic of)

    2014-04-15

    In this study, a new method based on Fe{sub 3}O{sub 4} magnetite nanoparticles (MNPs) has been developed for the extraction, preconcentration and determination of trace amounts of carbaryl from environmental water samples. Fe{sub 3}O{sub 4} MNPs were synthesized and modified by the surfactant sodium dodecyl sulfate (SDS), then successfully applied for the extraction of carbaryl and its determination by spectrofluorimetry. Main factors affecting the adsolubilization of carbaryl such as the amount of SDS, pH value, standing time, desorption solvent and maximal extraction volume were optimized. Under the selected conditions, carbaryl could be quantitatively extracted. Acceptable recoveries (84.5-91.9%) and relative standard deviations (6.2%) were achieved in analyzing spiked water samples. A concentration factor of 20 was achieved by the extraction of 100 mL of environmental water samples. The limit of detection and quantification were found to be 2.1 and 6.9 μg L{sup -1}, respectively. The proposed method was successfully applied for the extraction and determination of carbaryl in environmental water samples. (author)

  4. Influence of forced air volume on water evaporation during sewage sludge bio-drying.

    Science.gov (United States)

    Cai, Lu; Chen, Tong-Bin; Gao, Ding; Zheng, Guo-Di; Liu, Hong-Tao; Pan, Tian-Hao

    2013-09-01

    Mechanical aeration is critical to sewage sludge bio-drying, and the actual water loss caused by aeration can be better understood from investigations of the relationship between aeration and water evaporation from the sewage sludge bio-drying pile based on in situ measurements. This study was conducted to investigate the effects of forced air volume on the evaporation of water from a sewage sludge bio-drying pile. Dewatered sewage sludge was bio-dried using control technology for bio-drying, during which time the temperature, superficial air velocity and water evaporation were measured and calculated. The results indicated that the peak air velocity and water evaporation occurred in the thermophilic phase and second temperature-increasing phase, with the highest values of 0.063 ± 0.027 m s(-1) and 28.9 kg ton(-1) matrix d(-1), respectively, being observed on day 4. Air velocity above the pile during aeration was 43-100% higher than when there was no aeration, and there was a significantly positive correlation between air volume and water evaporation from day 1 to 15. The order of daily means of water evaporation was thermophilic phase > second temperature-increasing phase > temperature-increasing phase > cooling phase. Forced aeration controlled the pile temperature and improved evaporation, making it the key factor influencing water loss during the process of sewage sludge bio-drying. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Quantification of surface water volume changes in the Mackenzie Delta using satellite multi-mission data

    Science.gov (United States)

    Normandin, Cassandra; Frappart, Frédéric; Lubac, Bertrand; Bélanger, Simon; Marieu, Vincent; Blarel, Fabien; Robinet, Arthur; Guiastrennec-Faugas, Léa

    2018-02-01

    Quantification of surface water storage in extensive floodplains and their dynamics are crucial for a better understanding of global hydrological and biogeochemical cycles. In this study, we present estimates of both surface water extent and storage combining multi-mission remotely sensed observations and their temporal evolution over more than 15 years in the Mackenzie Delta. The Mackenzie Delta is located in the northwest of Canada and is the second largest delta in the Arctic Ocean. The delta is frozen from October to May and the recurrent ice break-up provokes an increase in the river's flows. Thus, this phenomenon causes intensive floods along the delta every year, with dramatic environmental impacts. In this study, the dynamics of surface water extent and volume are analysed from 2000 to 2015 by combining multi-satellite information from MODIS multispectral images at 500 m spatial resolution and river stages derived from ERS-2 (1995-2003), ENVISAT (2002-2010) and SARAL (since 2013) altimetry data. The surface water extent (permanent water and flooded area) peaked in June with an area of 9600 km2 (±200 km2) on average, representing approximately 70 % of the delta's total surface. Altimetry-based water levels exhibit annual amplitudes ranging from 4 m in the downstream part to more than 10 m in the upstream part of the Mackenzie Delta. A high overall correlation between the satellite-derived and in situ water heights (R > 0.84) is found for the three altimetry missions. Finally, using altimetry-based water levels and MODIS-derived surface water extents, maps of interpolated water heights over the surface water extents are produced. Results indicate a high variability of the water height magnitude that can reach 10 m compared to the lowest water height in the upstream part of the delta during the flood peak in June. Furthermore, the total surface water volume is estimated and shows an annual variation of approximately 8.5 km3 during the whole study period, with

  6. Variable-Volume Flushing (V-VF) device for water conservation in toilets

    Science.gov (United States)

    Jasper, Louis J., Jr.

    1993-01-01

    Thirty five percent of residential indoor water used is flushed down the toilet. Five out of six flushes are for liquid waste only, which requires only a fraction of the water needed for solid waste. Designers of current low-flush toilets (3.5-gal. flush) and ultra-low-flush toilets (1.5-gal. flush) did not consider the vastly reduced amount of water needed to flush liquid waste versus solid waste. Consequently, these toilets are less practical than desired and can be improved upon for water conservation. This paper describes a variable-volume flushing (V-VF) device that is more reliable than the currently used flushing devices (it will not leak), is simple, more economical, and more water conserving (allowing one to choose the amount of water to use for flushing solid and liquid waste).

  7. High volume hydraulic fracturing operations: potential impacts on surface water and human health.

    Science.gov (United States)

    Mrdjen, Igor; Lee, Jiyoung

    2016-08-01

    High volume, hydraulic fracturing (HVHF) processes, used to extract natural gas and oil from underground shale deposits, pose many potential hazards to the environment and human health. HVHF can negatively affect the environment by contaminating soil, water, and air matrices with potential pollutants. Due to the relatively novel nature of the process, hazards to surface waters and human health are not well known. The purpose of this article is to link the impacts of HVHF operations on surface water integrity, with human health consequences. Surface water contamination risks include: increased structural failure rates of unconventional wells, issues with wastewater treatment, and accidental discharge of contaminated fluids. Human health risks associated with exposure to surface water contaminated with HVHF chemicals include increased cancer risk and turbidity of water, leading to increased pathogen survival time. Future research should focus on modeling contamination spread throughout the environment, and minimizing occupational exposure to harmful chemicals.

  8. Gender moderates the association between dorsal medial prefrontal cortex volume and depressive symptoms in a subclinical sample.

    Science.gov (United States)

    Carlson, Joshua M; Depetro, Emily; Maxwell, Joshua; Harmon-Jones, Eddie; Hajcak, Greg

    2015-08-30

    Major depressive disorder is associated with lower medial prefrontal cortex volumes. The role that gender might play in moderating this relationship and what particular medial prefrontal cortex subregion(s) might be implicated is unclear. Magnetic resonance imaging was used to assess dorsal, ventral, and anterior cingulate regions of the medial prefrontal cortex in a normative sample of male and female adults. The Depression, Anxiety, and Stress Scale (DASS) was used to measure these three variables. Voxel-based morphometry was used to test for correlations between medial prefrontal gray matter volume and depressive traits. The dorsal medial frontal cortex was correlated with greater levels of depression, but not anxiety and stress. Gender moderates this effect: in males greater levels of depression were associated with lower dorsal medial prefrontal volumes, but in females no relationship was observed. The results indicate that even within a non-clinical sample, male participants with higher levels of depressive traits tend to have lower levels of gray matter volume in the dorsal medial prefrontal cortex. Our finding is consistent with low dorsal medial prefrontal volume contributing to the development of depression in males. Future longitudinal work is needed to substantiate this possibility. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. UMTRA Project water sampling and analysis plan, Belfield and Bowman, North Dakota

    International Nuclear Information System (INIS)

    1994-08-01

    Surface remedial action is scheduled to begin at the Belfield and Bowman Uranium Mill Tailings Remedial Action (UMTRA) Project sites in the spring of 1996. Water sampling was conducted in 1993 at both the Belfield processing site and the Bowman processing/disposal site. Results of the sampling at both sites indicate that ground water conditions have remained relatively stable over time. Water sampling activities are not scheduled for 1994 because ground water conditions at the two sites are relatively stable, the 1993 sampling was comprehensive, and surface remediation activities are not scheduled to start until 1996. The next water sampling event is scheduled before the start of remedial activities and will include sampling selected monitor wells at both sites and several domestic wells in the vicinity

  10. Concentration of polycyclic aromatic hydrocarbons in water samples from different stages of treatment

    Science.gov (United States)

    Pogorzelec, Marta; Piekarska, Katarzyna

    2017-11-01

    The aim of this study was to analyze the presence and concentration of selected polycyclic aromatic hydrocarbons in water samples from different stages of treatment and to verify the usefulness of semipermeable membrane devices for analysis of drinking water. For this purpose, study was conducted for a period of 5 months. Semipermeable membrane devices were deployed in a surface water treatment plant located in Lower Silesia (Poland). To determine the effect of water treatment on concentration of PAHs, three sampling places were chosen: raw water input, stream of water just before disinfection and treated water output. After each month of sampling SPMDs were changed for fresh ones and prepared for further analysis. Concentrations of fifteen polycyclic aromatic hydrocarbons were determined by high performance liquid chromatography (HPLC). Presented study indicates that the use of semipermeable membrane devices can be an effective tool for the analysis of aquatic environment, including monitoring of drinking water, where organic micropollutants are present at very low concentrations.

  11. Planck/SDSS Cluster Mass and Gas Scaling Relations for a Volume-Complete redMaPPer Sample

    Science.gov (United States)

    Jimeno, Pablo; Diego, Jose M.; Broadhurst, Tom; De Martino, I.; Lazkoz, Ruth

    2018-04-01

    Using Planck satellite data, we construct Sunyaev-Zel'dovich (SZ) gas pressure profiles for a large, volume-complete sample of optically selected clusters. We have defined a sample of over 8,000 redMaPPer clusters from the Sloan Digital Sky Survey (SDSS), within the volume-complete redshift region 0.100 trend towards larger break radius with increasing cluster mass. Our SZ-based masses fall ˜16% below the mass-richness relations from weak lensing, in a similar fashion as the "hydrostatic bias" related with X-ray derived masses. Finally, we derive a tight Y500-M500 relation over a wide range of cluster mass, with a power law slope equal to 1.70 ± 0.07, that agrees well with the independent slope obtained by the Planck team with an SZ-selected cluster sample, but extends to lower masses with higher precision.

  12. Method for volume reduction and encapsulation of water-bearing, low-level radioactive wastes

    International Nuclear Information System (INIS)

    1982-01-01

    The invention relates to the processing of water-bearing wastes, especially those containing radioactive materials from nuclear power plants like light-water moderated and cooled reactors. The invention provides a method to reduce the volume of wastes like contaminated coolants and to dispose them safely. According to the invention, azeotropic drying is applied to remove the water. Distilation temperatures are chosen to be lower than the lowest boiling point of the mixture components. In the preferred version, a polymerizing monomer is used to obtain the azeotropic mixture. In doing so, encapsulation is possible by combination with a co-reactive polymer that envelopes the waste material. (G.J.P.)

  13. Behaviour of Water Droplets Under the Influence of a Uniform Electric Field in Nanocomposite Samples of Epoxy Resin/TiO2

    Directory of Open Access Journals (Sweden)

    Α. Bairaktari

    2013-10-01

    Full Text Available In this paper nanocomposite samples of epoxy resin and TiO2 nanoparticles were investigated with water droplets on their surface. A uniform electric field was applied and the behaviour of the water droplets was observed. Parameters that were studied were the water conductivity, the droplet volume, the number of droplets and the droplet positioning with respect to (w.r.t. the electrodes. All above mentioned parameters influence the flashover voltage of the samples. It is to be noted that – at least in some cases – the water droplet positioning w.r.t. the electrodes was more important in determining the flashover voltage than the droplet volume.

  14. Procedures for field chemical analyses of water samples

    International Nuclear Information System (INIS)

    Korte, N.; Ealey, D.

    1983-12-01

    A successful water-quality monitoring program requires a clear understanding of appropriate measurement procedures in order to obtain reliable field data. It is imperative that the responsible personnel have a thorough knowledge of the limitations of the techniques being used. Unfortunately, there is a belief that field analyses are simple and straightforward. Yet, significant controversy as well as misuse of common measurement techniques abounds. This document describes procedures for field measurements of pH, carbonate and bicarbonate, specific conductance, dissolved oxygen, nitrate, Eh, and uranium. Each procedure section includes an extensive discussion regarding the limitations of the method as well as brief discussions of calibration procedures and available equipment. A key feature of these procedures is the consideration given to the ultimate use of the data. For example, if the data are to be used for geochemical modeling, more precautions are needed. In contrast, routine monitoring conducted merely to recognize gross changes can be accomplished with less effort. Finally, quality assurance documentation for each measurement is addressed in detail. Particular attention is given to recording sufficient information such that decisions concerning the quality of the data can be easily made. Application of the procedures and recommendations presented in this document should result in a uniform and credible water-quality monitoring program. 22 references, 4 figures, 3 tables

  15. Salinity independent volume fraction prediction in water-gas-oil multiphase flows using artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, C.M.; Pereira, Claudio M.N.A.; Brandao, Luis E.B., E-mail: otero@ien.gov.b, E-mail: cmnap@ien.gov.b, E-mail: brandao@ien.gov.b [Instituto de Engenharia Nuclear (DIRA/IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Radiofarmacos

    2011-07-01

    This work investigates the response of a volume fraction prediction system for water-gas-oil multiphase flows considering variations on water salinity. The approach is based on gamma-ray pulse height distributions pattern recognition by means the artificial neural networks (ANNs). The detection system uses appropriate fan beam geometry, comprised of a dual-energy gamma-ray source and two NaI(Tl) detectors adequately positioned outside the pipe in order measure transmitted and scattered beams. An ideal and static theoretical model for annular flow regime have been developed using MCNP-X code, which was used to provide training, test and validation data for the ANN. More than 500 simulations have been done, in which water salinity have been ranged from 0 to 16% in order to cover a most practical situations. Validation tests have included values of volume fractions and water salinity different from those used in ANN training phase. The results presented here show that the proposed approach may be successfully applied to material volume fraction prediction on watergas- oil multiphase flows considering practical (real) levels of variations in water salinity. (author)

  16. Salinity independent volume fraction prediction in water-gas-oil multiphase flows using artificial neural networks

    International Nuclear Information System (INIS)

    Salgado, C.M.; Pereira, Claudio M.N.A.; Brandao, Luis E.B.

    2011-01-01

    This work investigates the response of a volume fraction prediction system for water-gas-oil multiphase flows considering variations on water salinity. The approach is based on gamma-ray pulse height distributions pattern recognition by means the artificial neural networks (ANNs). The detection system uses appropriate fan beam geometry, comprised of a dual-energy gamma-ray source and two NaI(Tl) detectors adequately positioned outside the pipe in order measure transmitted and scattered beams. An ideal and static theoretical model for annular flow regime have been developed using MCNP-X code, which was used to provide training, test and validation data for the ANN. More than 500 simulations have been done, in which water salinity have been ranged from 0 to 16% in order to cover a most practical situations. Validation tests have included values of volume fractions and water salinity different from those used in ANN training phase. The results presented here show that the proposed approach may be successfully applied to material volume fraction prediction on watergas- oil multiphase flows considering practical (real) levels of variations in water salinity. (author)

  17. Final report on Phase II remedial action at the former Middlesex Sampling Plant and associated properties. Volume 2

    International Nuclear Information System (INIS)

    1985-04-01

    Volume 2 presents the radiological measurement data taken after remedial action on properties surrounding the former Middlesex Sampling Plant during Phase II of the DOE Middlesex Remedial Action Program. Also included are analyses of the confirmatory radiological survey data for each parcel with respect to the remedial action criteria established by DOE for the Phase II cleanup and a discussion of the final status of each property. Engineering details of this project and a description of the associated health physics and environmental monitoring activities are presented in Volume 1

  18. Fate and effects of nearshore discharges of OCS produced waters. Volume 2. Technical report (Final)

    International Nuclear Information System (INIS)

    Rabalais, N.N.; McKee, B.A.; Reed, D.J.; Means, J.C.

    1991-06-01

    While the number of facilities that discharge OCS produced waters into coastal environments of Louisiana are few in number, they account for large volumes, individually and collectively. Of the 15 facilities which discharge OCS-generated produced water into coastal environments of Louisiana (as of February 1990), 10 discharges in seven areas were studied. The discharge volumes of the study areas range from 3,000 to 106,000/bbl.d. The receiving environments for these effluents are varied, but include the shallow, nearshore continental shelf; high energy, freshwater distributaries of the Mississippi River delta; and brackish and saline coastal environments with moderately to poorly flushed waters. All study areas are within the Mississippi River Deltaic Plain. The study expanded on the initial assessment of Boesch and Rabalais (1989a) with increased temporal and spatial studies of three areas, additional study sites including an abandoned discharge, and additional analytical and field observations

  19. Water volume quantitation using nuclear magnetic resonance imaging: application to cerebrospinal fluid

    International Nuclear Information System (INIS)

    Lecouffe, P.; Huglo, D.; Dubois, P.; Rousseau, J.; Marchandise, X.

    1990-01-01

    Quantitation in proton NMR imaging is applied to cerebrospinal fluid (CSF). Total intracranial CSF volume was measured from Condon's method: CSF signal was compared with distilled water standard signal in a single sagittal thick slice. Brain signal was reduced to minimum using a 5000/360/400 sequence. Software constraints did not permit easy implementing on imager and uniformity correction was performed on a microcomputer. Accuracy was better than 4%. Total intracranial CSF was found between 91 and 164 ml in 5 healthy volunteers. Extraventricular CSF quantitation appears very improved by this method, but planimetric methods seem better in order to quantify ventricular CSF. This technique is compared to total lung water measurement from proton density according to Mac Lennan's method. Water volume quantitation confirms ability of NMR imaging to quantify biologic parameters but image defects have to be known by strict quality control [fr

  20. Determination of rare earth elements in natural water samples – A review of sample separation, preconcentration and direct methodologies

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, Andrew, E-mail: afisher@plymouth.ac.uk [School of Geography, Earth and Environmental Sciences, Plymouth University, Drake Circus, Plymouth, Devon, PL4 8AA (United Kingdom); Kara, Derya [Department of Chemistry, Art and Science Faculty, Balikesir University, 10100, Balikesir (Turkey)

    2016-09-07

    This review discusses and compares the methods given for the determination of rare earth elements (REE) in natural water samples, including sea, river, lake, tap, ground and waste waters as well as Antarctic ice. Since REE are at very low concentrations in natural waters, numerous different preconcentration methods have been proposed to enable their measurement. These include liquid liquid extraction, dispersive liquid-liquid micro-extraction and solidified floating drop micro-extraction. In addition to liquid-liquid extraction methods, solid phase extraction using commercial resins, resins made in-house, silica-based exchange materials and other solid media is also discussed. These and other techniques such as precipitation/co-precipitation and flotation are compared in terms of speed, preconcentration factors achieved, precision, accuracy and limits of detection (LOD). Some papers have discussed the direct determination of REE in these sample types. Some have used specialised sample introduction systems such as ultrasonic nebulization whereas others have used a standard sample introduction system coupled with inductively coupled plasma mass spectrometry (ICP-MS) detection. These direct methods have also been discussed and compared. - Highlights: • The determination of rare earth elements in waters is reviewed. • Assorted preconcentration techniques are discussed and evaluated. • Detection techniques include atomic spectrometry, potentiometry and spectrophotometry. • Special nebulisers and electrothermal vaporization approaches are reviewed.

  1. Optimizing human semen cryopreservation by reducing test vial volume and repetitive test vial sampling

    DEFF Research Database (Denmark)

    Jensen, Christian F S; Ohl, Dana A; Parker, Walter R

    2015-01-01

    OBJECTIVE: To investigate optimal test vial (TV) volume, utility and reliability of TVs, intermediate temperature exposure (-88°C to -93°C) before cryostorage, cryostorage in nitrogen vapor (VN2) and liquid nitrogen (LN2), and long-term stability of VN2 cryostorage of human semen. DESIGN......: Prospective clinical laboratory study. SETTING: University assisted reproductive technology (ART) laboratory. PATIENT(S): A total of 594 patients undergoing semen analysis and cryopreservation. INTERVENTION(S): Semen analysis, cryopreservation with different intermediate steps and in different volumes (50......-1,000 μL), and long-term storage in LN2 or VN2. MAIN OUTCOME MEASURE(S): Optimal TV volume, prediction of cryosurvival (CS) in ART procedure vials (ARTVs) with pre-freeze semen parameters and TV CS, post-thaw motility after two- or three-step semen cryopreservation and cryostorage in VN2 and LN2. RESULT...

  2. Influence of Water Absorption on Volume Resistivity and the Dielectric Properties of Neat Epoxy Material

    KAUST Repository

    Sulaimani, Anwar Ali

    2014-07-15

    Influence of Water Absorption on the Dielectric Properties and Volume Resistivity of Neat Epoxy Material Anwar Ali Sulaimani Epoxy resins are widely used materials in the industry as electrical insulators, adhesives and in aircrafts structural components because of their high mechanical sti ness, strength and high temperature and chemical resistance properties. But still, the in uence of water uptake due to moisture adsorption is not fully understood as it detrimentally modi es the electrical and chemical properties of the material. Here, we investigate the in uence of water moisture uptake on the neat epoxy material by monitoring the change in the volume resistivity and dielectric properties of epoxy material at three di erent thickness con gurations: 0.250 mm, 0.50 mm and 1 mm thicknesses. Gravimetric analysis was done to monitor the mass uptake behaviour, Volume Resistivity was measured to monitor the change in conductivity of the material, and the dielectric properties were mapped to characterise the type of water mechanism available within the material during two ageing processes of sorption and desorption. Two-stage behaviours of di usion and reaction have been identi ed by the mass uptake analysis. Moreover, the plot of volume resistivity versus mass uptake has indi- cated a non-uniform relationship between the two quantities. However, the analysis of the dielectric spectrum at medium range of frequency and time has showed a change 5 in the dipolar activities and also showed the extent to which the water molecules can be segregated between bounding to the resin or existing as free water.

  3. 222Rn in water: A comparison of two sample collection methods and two sample transport methods, and the determination of temporal variation in North Carolina ground water

    International Nuclear Information System (INIS)

    Hightower, J.H. III

    1994-01-01

    Objectives of this field experiment were: (1) determine whether there was a statistically significant difference between the radon concentrations of samples collected by EPA's standard method, using a syringe, and an alternative, slow-flow method; (2) determine whether there was a statistically significant difference between the measured radon concentrations of samples mailed vs samples not mailed; and (3) determine whether there was a temporal variation of water radon concentration over a 7-month period. The field experiment was conducted at 9 sites, 5 private wells, and 4 public wells, at various locations in North Carolina. Results showed that a syringe is not necessary for sample collection, there was generally no significant radon loss due to mailing samples, and there was statistically significant evidence of temporal variations in water radon concentrations

  4. [Detection of Cryptospordium spp. in environmental water samples by FTA-PCR].

    Science.gov (United States)

    Zhang, Xiao-Ping; Zhu, Qian; He, Yan-Yan; Jiang, Li; Jiang, Shou-Fu

    2011-02-01

    To establish a FTA-polymeras chain reaction (FTA-PCR) method in detection of Cryptospordium spp. in different sources of water. The semi automated immunomagnetic separation (IMS) of Cryptospordium oocysts in environmental water samples was performed firstly, and then genomic DNA of Cryptospordium oocysts was extracted by FTA filters disk. Oligonucleotide primers were designed based on the DNA fragment of the 18 S rRNA gene from C. parvum. Plate DNA was amplified with primers in PCR. The control DNA samples from Toxoplasma gondii,Sarcocystis suihominis, Echinococcus granulosus, and Clonorchis sinensis were amplified simultaneously. All PCR products were detected by agar electrophoresis dyed with ethidium bromide. The 446 bp fragment of DNA was detected in all samples of C. parvum, C. andersoni, and C. baileyi, while it was not detected in control groups in laboratory. No positive samples were found from 10 samples collected from tape water in 5 districts of Shanghai City by FTA-PCR. Nine positive samples were detected totally from 70 different environmental water samples, there were 0 out of 15 samples from the source of tape water, 2 out of 25 from the Huangpu River, 5 out of 15 from rivers around the animal farmers, 1 out of 9 from output water of contaminating water treatment factory, 1 out of 6 from the out gate of living contaminating water. The 446 bp fragment was detected from all the amplified positive water samples. FTA-PCR is an efficient method for gene detection of Cryptospordium oocysts, which could be used in detection of environmental water samples. The contamination degree of Cryptospordium oocysts in the river water around animal farms is high.

  5. UMTRA Project water sampling and analysis plan, Gunnison, Colorado. Revision 2

    International Nuclear Information System (INIS)

    1995-09-01

    Surface remedial action at the Gunnison Uranium Mill Tailings Remedial Action Project site began in 1992; completion is expected in 1995. Ground water and surface water will be sampled semiannually at the Gunnison processing site (GUN-01) and disposal site (GUN-08). Results of previous water sampling at the Gunnison processing site indicate that ground water in the alluvium is contaminated by the former uranium processing activities. Background ground water conditions have been established in the uppermost aquifer (Tertiary gravels) at the Gunnison disposal site. Semiannual water sampling is scheduled for the spring and fall. Water quality sampling is conducted at the processing site (1) to ensure protection of human health and the environment, (2) for ground water compliance monitoring during remedial action construction, and (3) to define the extent of contamination. At the processing site, the frequency and duration of sampling will be dependent upon the nature and extent of residual contamination and the compliance strategy chosen. The monitor well locations provide a representative distribution of sampling points to characterize ground water quality and ground water flow conditions in the vicinity of the sites. The list of analytes has been modified with time to reflect constituents that are related to uranium processing activities and the parameters needed for geochemical evaluation

  6. Hanford Environmental Information System (HEIS). Volume 7: Sample and Data Tracking subject area

    International Nuclear Information System (INIS)

    1994-06-01

    The Hanford Environmental Information System (HEIS) Sample and Data Tracking subject area allows insertion of tracking information into a central repository where the data is immediately available for viewing. For example, a technical coordinator is able to view the current status of a particular sampling effort, from sample collection to data package validation dates. Four major types of data comprise the Sample and Data Tracking subject area: data about the mechanisms that groups a set of samples for a particular sampling effort; data about how constituents are grouped and assigned to a sample; data about when, where, and how samples are sent to a laboratory for analysis; and data bout the status of a sample's constituent analysis requirements, i.e., whether the analysis results have been returned from the laboratory

  7. Box-Behnken design in modeling of solid-phase tea waste extraction for the removal of uranium from water samples

    International Nuclear Information System (INIS)

    Khajeh, Mostafa; Jahanbin, Elham; Ghaffari-Moghaddam, Mansour; Moghaddam, Zahra Safaei; Bohlooli, Mousa

    2015-01-01

    In this study, the solid-phase tea waste procedure was used for separation, preconcentration and determination of uranium from water samples by UV-Vis spectrophotometer. In addition, Box-Behnken experimental design was employed to investigated the influence of six variables including pH, mass of adsorbent, eluent volume, amount of 1-(2-pyridylazo)-2-naphthol (PAN); and sample and eluent flow rates on the extraction of analyte. High determination coefficient (R 2 ) of 0.972 and adjusted-R 2 of 0.943 showed the satisfactory adjustment of the polynomial regression model. This method was used for the extraction of uranium from real water samples.

  8. Volume of baseline data on radioactivity in drinking water, ground water, waste water, sewage sludge, residues and wastes of the annual report 1988 'Environmental radioactivity and radiation exposure'

    International Nuclear Information System (INIS)

    Abelmann, S.; Buenger, T.; Fusban, H.U.; Ruehle, H.; Viertel, H.; Gans, I.

    1991-01-01

    This WaBoLu volume is a shortened version of the annual report by the Federal Ministry of the Environment, Nature Protection and Reactor Safety 'Environmental radioactivity and radiation exposure' and gives an overview of the data on radioactivity in drinking water, ground water, waste water, sewage sludge, residues and wastes, compiled for the area of the Federal Republic of Germany in 1988 by the Institute of Water, Soil and Air Hygiene (WaBoLu) of the Federal Health Office. (BBR) With 22 figs., 15 tabs [de

  9. Determination of radiocesium in environmental water samples using copper ferro(II)cyanide and sodium tetraphenylborate

    International Nuclear Information System (INIS)

    Popov, L.; Kuleff, I.; Djingova, R.

    2006-01-01

    A procedure for the radiochemical separation and radiochemical purification of radiocesium ( 134 Cs and 137 Cs) in bulk environmental water samples is proposed. Radiocesium was removed from the water by cation-exchange with copper ferro(II)cyanide and was purified by precipitation with sodium tetraphenylborate. The influence of the concentration of potassium in the water sample on the chemical yield was investigated. The validation of the proposed method was carried out by analyzing reference materials. The application of the method was demonstrated with the determination of the concentration of radiocesium in water samples from rivers around NPP 'Kozloduy', Bulgaria, Danube and Ogosta. (author)

  10. Uranium content measurement in drinking water samples using track etch technique

    International Nuclear Information System (INIS)

    Kumar, Mukesh; Kumar, Ajay; Singh, Surinder; Mahajan, R.K.; Walia, T.P.S.

    2003-01-01

    The concentration of uranium has been assessed in drinking water samples collected from different locations in Bathinda district, Punjab, India. The water samples are taken from hand pumps and tube wells. Uranium is determined using fission track technique. Uranium concentration in the water samples varies from 1.65±0.06 to 74.98±0.38 μg/l. These values are compared with safe limit values recommended for drinking water. Most of the water samples are found to have uranium concentration above the safe limit. Analysis of some heavy metals (Zn, Cd, Pb and Cu) in water is also done in order to see if some correlation exists between the concentration of uranium and these heavy metals. A weak positive correlation has been observed between the concentration of uranium and heavy metals of Pb, Cd and Cu

  11. Water resources data, Idaho, 2002; Volume 1. Great Basin and Snake River basin above King Hill

    Science.gov (United States)

    Brennan, T.S.; Lehmann, A.K.; Campbell, A.M.; O'Dell, I.; Beattie, S.E.

    2003-01-01

    Water resources data for the 2002 water year for Idaho consists of records of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes and reservoirs; discharge of irrigation diversions; and water levels and water quality of groundwater. The two volumes of this report contain discharge records for 196 stream-gaging stations and 15 irrigation diversions; stage only records for 5 stream-gaging stations; stage only for 6 lakes and reservoirs; contents only for 13 lakes and reservoirs; water-quality for 78 stream-gaging stations and partial record sites, 3 lakes sites, and 383 groundwater wells; and water levels for 425 observation network wells and 900 special project wells. Additional water data were collected at various sites not involved in the systematic data collection program and are published as miscellaneous measurements. These data represent that part of the National Water Data System operated by the U.S. Geological Survey and cooperating State and Federal agencies in Idaho, adjacent States, and Canada.

  12. Investigating the pore-water chemistry effects on the volume change behaviour of Boom clay

    Science.gov (United States)

    Deng, Y. F.; Cui, Y. J.; Tang, A. M.; Nguyen, X. P.; Li, X. L.; Van Geet, M.

    The Essen site has been chosen as an alternative site for nuclear waste disposal in Belgium. The soil formation involved at this site is the same as at Mol site: Boom clay. However, owing to its geographical situation closer to the sea, Boom clay at Essen presents a pore water salinity 4-5 times higher than Boom clay at Mol. This study aims at studying the effects of pore water salinity on the hydro-mechanical behaviour of Boom clay. Specific oedometer cells were used allowing “flushing” the pore water in soil specimen by synthetic pore water or distilled water. The synthetic pore water used was prepared with the chemistry as that for the site water: 5.037 g/L for core Ess83 and 5.578 g/L for core Ess96. Mechanical loading was then carried out on the soil specimen after flushing. The results show that water salinity effect on the liquid limit is negligible. The saturation or pore water replacement under the in situ effective stress of 2.4 MPa does not induce significant volume change. For Ess83, hydro-mechanical behaviour was found to be slightly influenced by the water salinity; on the contrary, no obvious effect was identified on the hydro-mechanical behaviour of Ess96. This can be attributed to the higher smectite content in Ess83 than in Ess96.

  13. An immunomagnetic separator for concentration of pathogenic micro-organisms from large volume samples

    International Nuclear Information System (INIS)

    Rotariu, Ovidiu; Ogden, Iain D.; MacRae, Marion; Badescu, Vasile; Strachan, Norval J.C.

    2005-01-01

    The standard method of immunomagnetic separation of pathogenic bacteria from food and environmental matrices processes 1 ml volumes. Pathogens present at low levels ( 50 ml). Preliminary results show that between 70 and 113 times more Escherchia coli O157 are recovered compared with the standard 1 ml method

  14. Curvature computation in volume-of-fluid method based on point-cloud sampling

    Science.gov (United States)

    Kassar, Bruno B. M.; Carneiro, João N. E.; Nieckele, Angela O.

    2018-01-01

    This work proposes a novel approach to compute interface curvature in multiphase flow simulation based on Volume of Fluid (VOF) method. It is well documented in the literature that curvature and normal vector computation in VOF may lack accuracy mainly due to abrupt changes in the volume fraction field across the interfaces. This may cause deterioration on the interface tension forces estimates, often resulting in inaccurate results for interface tension dominated flows. Many techniques have been presented over the last years in order to enhance accuracy in normal vectors and curvature estimates including height functions, parabolic fitting of the volume fraction, reconstructing distance functions, coupling Level Set method with VOF, convolving the volume fraction field with smoothing kernels among others. We propose a novel technique based on a representation of the interface by a cloud of points. The curvatures and the interface normal vectors are computed geometrically at each point of the cloud and projected onto the Eulerian grid in a Front-Tracking manner. Results are compared to benchmark data and significant reduction on spurious currents as well as improvement in the pressure jump are observed. The method was developed in the open source suite OpenFOAM® extending its standard VOF implementation, the interFoam solver.

  15. Selective solid-phase extraction of Ni(II) by an ion-imprinted polymer from water samples

    International Nuclear Information System (INIS)

    Saraji, Mohammad; Yousefi, Hamideh

    2009-01-01

    A new ion-imprinted polymer (IIP) material was synthesized by copolymerization of 4-vinylpyridine as monomer, ethyleneglycoldimethacrylate as crosslinking agent and 2,2'-azobis-sobutyronitrile as initiator in the presence of Ni-dithizone complex. The IIP was used as sorbent in a solid-phase extraction column. The effects of sampling volume, elution conditions, sample pH and sample flow rate on the extraction of Ni ions form water samples were studied. The maximum adsorption capacity and the relative selectivity coefficients of imprinted polymer for Ni(II)/Co(II), Ni(II)/Cu(II) and Ni(II)/Cd(II) were calculated. Compared with non-imprinted polymer particles, the IIP had higher selectivity for Ni(II). The relative selectivity factor (α r ) values of Ni(II)/Co(II), Ni(II)/Cu(II) and Ni(II)/Cd(II) were 21.6, 54.3, and 22.7, respectively, which are greater than 1. The relative standard deviation of the five replicate determinations of Ni(II) was 3.4%. The detection limit for 150 mL of sample was 1.6 μg L -1 using flame atomic absorption spectrometry. The developed method was successfully applied to the determination of trace nickel in water samples with satisfactory results.

  16. USDA Forest Service national protocols for sampling air pollution-sensitive waters

    Science.gov (United States)

    T. J. Sullivan

    2012-01-01

    The first step in designing a surface water sampling program is identifying one or more problems or questions that require information on water quality. Common water quality problems include nutrient enrichment (from a variety of causes), effects of atmospheric deposition (acidification, eutrophication, toxicity), and effects of major disturbances such as fire or pest...

  17. Evaluation of the Bacterial Status of Water Samples at Umudike Abia ...

    African Journals Online (AJOL)

    77.78%), Proteus spp.(66.67%), Serratia spp.(55.5%) and Vibro spp.(22.2%). The occurrence of the water borne pathogens appeared limited to the stream water samples, hence, continuous consumption without adequate treatment is potentially dangerous. Keywords: Water, rainwater, stream, bacteria, coliforms, pathogen ...

  18. UMTRA Project water sampling and analysis plan, Durango, Colorado. Revision 1

    International Nuclear Information System (INIS)

    1995-09-01

    Planned, routine ground water sampling activities at the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site in Durango, Colorado, are described in this water sampling and analysis plan. The plan identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the routine monitoring stations at the site. The ground water data are used to characterize the site ground water compliance strategies and to monitor contaminants of potential concern identified in the baseline risk assessment (DOE, 1995a). Regulatory basis for routine ground water monitoring at UMTRA Project sites is derived from the US EPA regulations in 40 CFR Part 192 (1994) and EPA standards of 1995 (60 FR 2854). Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), the Technical Approach Document (TAD) (DOE, 1989), and the most effective technical approach for the site

  19. A new adsorption-elution technique for the concentration of aquatic extracellular antibiotic resistance genes from large volumes of water.

    Science.gov (United States)

    Wang, Da-Ning; Liu, Lu; Qiu, Zhi-Gang; Shen, Zhi-Qiang; Guo, Xuan; Yang, Dong; Li, Jing; Liu, Wei-Li; Jin, Min; Li, Jun-Wen

    2016-04-01

    Extracellular antibiotic resistance genes (eARGs) that help in the transmission and spread of antibiotic-resistant bacteria are emerging environmental contaminants in water, and there is therefore a growing need to assess environmental levels and associated risks of eARGs. However, as they are present in low amounts, it is difficult to detect eARGs in water directly with PCR techniques. Here, we prepared a new type of nucleic acid adsorption particle (NAAP) with high capacity and developed an optimal adsorption-elution method to concentrate eARGs from large volumes of water. With this technique, we were able to achieve an eARG recovery rate of above 95% from 10 L of water samples. Moreover, combining this new method with quantitative real-time PCR (qPCR), the sensitivity of the eARG detection was 10(4) times that of single qPCR, with the detection limit lowered to 100 gene copies (GCs)/L. Our analyses showed that the eARG load, virus load and certain water characteristics such as pH, chemical oxygen demand (CODMn), and turbidity affected the eARGs recovery rate. However, high eARGs recovery rates always remained within the standard limits for natural surface water quality, while eARG levels in water were lower than the detection limits of single qPCR assays. The recovery rates were not affected by water temperature and heterotrophic plate counts (HPC). The eARGs whatever located in the plasmids or the short-length linear DNAs can be recovered from the water. Furthermore, the recovery rate was high even in the presence of high concentrations of plasmids in different natural water (Haihe river, well water, raw water for drinking water, Jinhe river, Tuanbo lake and the Yunqiao reservoir). By this technology, eARGs concentrations were found ranging from (2.70 ± 0.73) × 10(2) to (4.58 ± 0.47) × 10(4) GCs/L for the extracellular ampicillin resistance gene and (5.43 ± 0.41) × 10(2) to (2.14 ± 0.23) × 10(4) GCs/L for the extracellular gentamicin

  20. SCALE-4 analysis of pressurized water reactor critical configurations. Volume 1: Summary

    International Nuclear Information System (INIS)

    DeHart, M.D.

    1995-03-01

    The requirements of ANSI/ANS 8.1 specify that calculational methods for away-from-reactor criticality safety analyses be validated against experimental measurements. If credit is to be taken for the reduced reactivity of burned or spent fuel relative to its original fresh composition, it is necessary to benchmark computational methods used in determining such reactivity worth against spent fuel reactivity measurements. This report summarizes a portion of the ongoing effort to benchmark away-from-reactor criticality analysis methods using critical configurations from commercial pressurized water reactors (PWR). The analysis methodology utilized for all calculations in this report is based on the modules and data associated with the SCALE-4 code system. Each of the five volumes comprising this report provides an overview of the methodology applied. Subsequent volumes also describe in detail the approach taken in performing criticality calculations for these PWR configurations: Volume 2 describes criticality calculations for the Tennessee Valley Authority's Sequoyah Unit 2 reactor for Cycle 3; Volume 3 documents the analysis of Virginia Power's Surry Unit 1 reactor for the Cycle 2 core; Volume 4 documents the calculations performed based on GPU Nuclear Corporation's Three Mile Island Unit 1 Cycle 5 core; and, lastly, Volume 5 describes the analysis of Virginia Power's North Anna Unit 1 Cycle 5 core. Each of the reactor-specific volumes provides the details of calculations performed to determine the effective multiplication factor for each reactor core for one or more critical configurations using the SCALE-4 system; these results are summarized in this volume. Differences between the core designs and their possible impact on the criticality calculations are also discussed. Finally, results are presented for additional analyses performed to verify that solutions were sufficiently converged

  1. Water sampling using a drone at Yugama crater lake, Kusatsu-Shirane volcano, Japan

    Science.gov (United States)

    Terada, Akihiko; Morita, Yuichi; Hashimoto, Takeshi; Mori, Toshiya; Ohba, Takeshi; Yaguchi, Muga; Kanda, Wataru

    2018-04-01

    Remote sampling of water from Yugama crater lake at Kusatsu-Shirane volcano, Japan, was performed using a drone. Despite the high altitude of over 2000 m above sea level, our simple method was successful in retrieving a 250 mL sample of lake water. The procedure presented here is easy for any researcher to follow who operates a drone without additional special apparatus. We compare the lake water sampled by drone with that sampled by hand at a site where regular samplings have previously been carried out. Chemical concentrations and stable isotope ratios are largely consistent between the two techniques. As the drone can fly automatically with the aid of navigation by Global Navigation Satellite System (GNSS), it is possible to repeatedly sample lake water from the same location, even when entry to Yugama crater lake is restricted due to the risk of eruption.[Figure not available: see fulltext.

  2. National Coral Reef Monitoring Program: Water Chemistry of the Coral Reefs in American Samoa from Water Samples collected since 2015

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Water samples are collected and analyzed to assess spatial and temporal variation in the seawater carbonate systems of coral reef ecosystems in the Hawaiian and...

  3. Determination of thiobencarb in water samples by gas chromatography using a homogeneous liquid-liquid microextraction via flotation assistance procedure

    Directory of Open Access Journals (Sweden)

    H.A. Mashayekhi

    2013-09-01

    Full Text Available Homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA coupled with gas chromatography-flame ionization detection (GC-FID was applied for the extraction and determination of thiobencarb in water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added into the extraction cell which contained an appropriate mixture of toluene (as an extraction solvent and acetone (as a homogeneous solvent. By using air flotation, the organic solvent was collected at the conical part of the designed cell. The effect of the different parameters on the efficiency of extraction such as type and volume of extraction and homogeneous solvents, ionic strength and extraction time were studied and optimized. Under the optimal conditions, linearity of the method was in the range of 1.0-200 µg L-1. The relative standard deviations in the real samples varied from 7.8-11.7 % (n = 3. The proposed method was successfully applied to analysis of thiobencarb in the water samples and satisfactory results were obtained.DOI: http://dx.doi.org/10.4314/bcse.v27i3.4

  4. Magnetic solid-phase extraction of tetracyclines using ferrous oxide coated magnetic silica microspheres from water samples.

    Science.gov (United States)

    Lian, Lili; Lv, Jinyi; Wang, Xiyue; Lou, Dawei

    2018-01-26

    A novel magnetic solid-phase extraction approach was proposed for extraction of potential residues of tetracyclines (TCs) in tap and river water samples, based on Fe 3 O 4 @SiO 2 @FeO magnetic nanocomposite. Characterized results showed that the received Fe 3 O 4 @SiO 2 @FeO had distinguished magnetism and core-shell structure. Modified FeO nanoparticles with an ∼5 nm size distribution were homogeneously dispersed on the surface of the silica shell. Owing to the strong surface affinity of Fe (II) toward TCs, the magnetic nanocomposite could be applied to efficiently extract three TCs antibiotics, namely, oxytetracycline, tetracycline and chlortetracycline from water samples. Several factors, such as sorbent amount, pH condition, adsorption and desorption time, desorption solvent, selectivity and sample volume, influencing the extraction performance of TCs were investigated and optimized. The developed method showed excellent linearity (R > 0.9992) in the range of 0.133-333 μg L -1 , under optimized conditions. The limits of detection were between 0.027 and 0.107 μg L -1 for oxytetracycline, tetracycline and chlortetracycline, respectively. The feasibility of this method was evaluated by analysis of tap and river water samples. The recoveries at the spiked concentration levels ranged from 91.0% to 104.6% with favorable reproducibility (RSD < 4%). Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Quantification of gastrointestinal liquid volumes and distribution following a 240 mL dose of water in the fasted state.

    Science.gov (United States)

    Mudie, Deanna M; Murray, Kathryn; Hoad, Caroline L; Pritchard, Susan E; Garnett, Martin C; Amidon, Gordon L; Gowland, Penny A; Spiller, Robin C; Amidon, Gregory E; Marciani, Luca

    2014-09-02

    The rate and extent of drug dissolution and absorption from solid oral dosage forms is highly dependent upon the volumes and distribution of gastric and small intestinal water. However, little is known about the time courses and distribution of water volumes in vivo in an undisturbed gut. Previous imaging studies offered a snapshot of water distribution in fasted humans and showed that water in the small intestine is distributed in small pockets. This study aimed to quantify the volume and number of water pockets in the upper gut of fasted healthy humans following ingestion of a glass of water (240 mL, as recommended for bioavailability/bioequivalence (BA/BE) studies), using recently validated noninvasive magnetic resonance imaging (MRI) methods. Twelve healthy volunteers underwent upper and lower abdominal MRI scans before drinking 240 mL (8 fluid ounces) of water. After ingesting the water, they were scanned at intervals for 2 h. The drink volume, inclusion criteria, and fasting conditions matched the international standards for BA/BE testing in healthy volunteers. The images were processed for gastric and intestinal total water volumes and for the number and volume of separate intestinal water pockets larger than 0.5 mL. The fasted stomach contained 35 ± 7 mL (mean ± SEM) of resting water. Upon drinking, the gastric fluid rose to 242 ± 9 mL. The gastric water volume declined rapidly after that with a half emptying time (T50%) of 13 ± 1 min. The mean gastric volume returned back to baseline 45 min after the drink. The fasted small bowel contained a total volume of 43 ± 14 mL of resting water. Twelve minutes after ingestion of water, small bowel water content rose to a maximum value of 94 ± 24 mL contained within 15 ± 2 pockets of 6 ± 2 mL each. At 45 min, when the glass of water had emptied completely from the stomach, total intestinal water volume was 77 ± 15 mL distributed into 16 ± 3 pockets of 5 ± 1 mL each. MRI provided unprecedented insights into

  6. UMTRA project water sampling and analysis plan, Salt Lake City, Utah

    International Nuclear Information System (INIS)

    1994-06-01

    Surface remedial action was completed at the Salt Lake City, Utah, Uranium Mill Tailings Remedial Action (UMTRA) Project site in the fall of 1987. Results of water sampling for the years 1992 to 1994 indicate that site-related ground water contamination occurs in the shallow unconfined aquifer (the uppermost aquifer). With respect to background ground water quality, contaminated ground water in the shallow, unconfined aquifer has elevated levels of chloride, sodium, sulfate, total dissolved solids, and uranium. No contamination associated with the former tailings pile occurs in levels exceeding background in ground water in the deeper confined aquifer. This document provides the water sampling and analysis plan for ground water monitoring at the former uranium processing site in Salt Lake City, Utah (otherwise known as the ''Vitro'' site, named after the Vitro Chemical Company that operated the mill). All contaminated materials removed from the processing site were relocated and stabilized in a disposal cell near Clive, Utah, some 85 miles west of the Vitro site (known as the ''Clive'' disposal site). No ground water monitoring is being performed at the Clive disposal site, since concurrence of the remedial action plan by the US Nuclear Regulatory Commission and completion of the disposal cell occurred before the US Environmental Protection Agency issued draft ground water standards in 1987 (52 FR 36000) for cleanup, stabilization, and control of residual radioactive materials at the disposal site. In addition, the likelihood of post-closure impact on the ground water is minimal to nonexistent, due to the naturally poor quality of the ground water. Water sampling activities planned for calendar year 1994 consist of sampling ground water from nine monitor wells to assess the migration of contamination within the shallow unconfined aquifer and sampling ground water from two existing monitor wells to assess ground water quality in the confined aquifer

  7. Application of response surface methodology for determination of methyl red in water samples by spectrophotometry method.

    Science.gov (United States)

    Khodadoust, Saeid; Ghaedi, Mehrorang

    2014-12-10

    In this study a rapid and effective method (dispersive liquid-liquid microextraction (DLLME)) was developed for extraction of methyl red (MR) prior to its determination by UV-Vis spectrophotometry. Influence variables on DLLME such as volume of chloroform (as extractant solvent) and methanol (as dispersive solvent), pH and ionic strength and extraction time were investigated. Then significant variables were optimized by using a Box-Behnken design (BBD) and desirability function (DF). The optimized conditions (100μL of chloroform, 1.3mL of ethanol, pH 4 and 4% (w/v) NaCl) resulted in a linear calibration graph in the range of 0.015-10.0mgmL(-1) of MR in initial solution with R(2)=0.995 (n=5). The limits of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.015mgmL(-1), respectively. Finally, the DLLME method was applied for determination of MR in different water samples with relative standard deviation (RSD) less than 5% (n=5). Copyright © 2014 Elsevier B.V. All rights reserved.

  8. The determination of chromium in water samples by neutron activation analysis after preconcentration on activated carbon

    International Nuclear Information System (INIS)

    Sloot, H.A. van der

    1977-01-01

    A method is presented for the determination of chromium in sea- and fresh water. Chromium is concentrated on activated carbon from a neutral solution after a previous reduction of chromate with sodium sulfite at pH 1.5. The adsorption conditions, acidity, concentrations, amount of carbon, stirring-time, sample-volume, salinity, the influence of storage on the ratio of tervalent to hexavalent chromium, were investigated. The final determination of the total chromium content is performed by instrumental neutron-activation analysis. By preconcentration on activated carbon, a differentiation between tervalent and hexavalent chromium is possible. A separate determination of both species is not yet feasible due to the high carbon blank and to the necessity of measuring the adsorption percentage on carbon. The lower limit of determination, which depends on the value of the carbon blank, is 0.05 μg Cr/l with a precision of 20%. The determination is hampered by the considerable blank from the carbon. The use of activated carbon prepared from recrystallized sugar will probably improve the lower limit of determination and possibly allow the determination of chromate. (T.G.)

  9. Determination of chromium in water samples by neutron activation analysis after preconcentration on activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    van der Sloot, H A [Stichting Reactor Centrum Nederland, Petten

    1977-01-01

    A method is presented for the determination of chromium in sea- and fresh water. Chromium is concentrated on activated carbon from a neutral solution after a previous reduction of chromate with sodium sulfite at pH 1.5. The adsorption conditions, acidity, concentrations, amount of carbon, stirring-time, sample-volume, salinity, the influence of storage on the ratio of tervalent to hexavalent chromium, were investigated. The final determination of the total chromium content is performed by instrumental neutron-activation analysis. By preconcentration on activated carbon, a differentiation between tervalent and hexavalent chromium is possible. A separate determination of both species is not yet feasible due to the high carbon blank and to the necessity of measuring the adsorption percentage on carbon. The lower limit of determination, which depends on the value of the carbon blank, is 0.05 ..mu..g Cr/l with a precision of 20%. The determination is hampered by the considerable blank from the carbon. The use of activated carbon prepared from recrystallized sugar will probably improve the lower limit of determination and possibly allow the determination of chromate.

  10. Application of response surface methodology for determination of methyl red in water samples by spectrophotometry method

    Science.gov (United States)

    Khodadoust, Saeid; Ghaedi, Mehrorang

    2014-12-01

    In this study a rapid and effective method (dispersive liquid-liquid microextraction (DLLME) was developed for extraction of methyl red (MR) prior to its determination by UV-Vis spectrophotometry. Influence variables on DLLME such as volume of chloroform (as extractant solvent) and methanol (as dispersive solvent), pH and ionic strength and extraction time were investigated. Then significant variables were optimized by using a Box-Behnken design (BBD) and desirability function (DF). The optimized conditions (100 μL of chloroform, 1.3 mL of ethanol, pH 4 and 4% (w/v) NaCl) resulted in a linear calibration graph in the range of 0.015-10.0 mg mL-1 of MR in initial solution with R2 = 0.995 (n = 5). The limits of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.015 mg mL-1, respectively. Finally, the DLLME method was applied for determination of MR in different water samples with relative standard deviation (RSD) less than 5% (n = 5).

  11. Volume de água armazenado no tanque de bromélias, em restingas da costa brasileira Water volume stored in bromeliad tanks in Brazilian restinga habitats

    Directory of Open Access Journals (Sweden)

    Luciana Cogliatti-Carvalho

    2010-03-01

    Full Text Available Muitas espécies de bromélias armazenam água da chuva em seu interior, sendo esta característica resultado da distribuição espiralada de suas folhas, que formam pequenos tanques. O objetivo deste estudo foi avaliar e comparar o volume de água efetivamente armazenado e o volume máximo que pode ser armazenado no tanque de diferentes espécies de bromélias de 13 restingas brasileiras. Em cada restinga, em 100 plots de 100 m² cada, registramos as espécies de bromélias-tanque, os parâmetros morfométricos e o volume efetivo e máximo em 20 indivíduos de cada espécie. Encontramos 32 espécies de bromélias-tanque, para as quais medimos o volume máximo e o volume efetivo de água armazenado. Em 59.007 rosetas, estimamos o volume máximo em 44.388 litros e medimos 17.000 litros de água efetivamente armazenados. Encontramos diferenças interespecíficas nos volumes máximo e efetivamente reservado de água, na biomassa, no número de folhas e no volume do cone da planta. Aechmea aquilega, A. blanchetiana e Hohenbergia castelanosii tiveram os maiores volumes efetivos. Somente A. nudicaulis e Billbergia amoena diferiram entre suas populações em todos os parâmetros analisados. As restingas de Maricá, Prado, Trancoso e Jurubatiba tiveram os maiores volumes de água.ha-1 armazenada nas bromélias-tanque. O volume máximo de água estimado para as bromélias-tanque variou entre espécies devido a diferenças na forma e no tamanho das bromélias.Many bromeliad species store rain water in tanks, as a result of the spiraled distribution of their leaves. The aim of this study was to evaluate how much water is stored and what is the maximum volume of water possible to be stored in different tank-bromeliad species in 13 different Brazilian restingas. The species were recorded in 100 plots of 100 m2, in each restinga habitat. For each bromeliad species, the effective and the maximum water stored in the tanks were measured. We found 32 tank

  12. Pore volume and pore size distribution of cement samples measured by a modified mercury intrusion porosimeter

    International Nuclear Information System (INIS)

    Zamorani, E.; Blanchard, H.

    1987-01-01

    Important parameters for the characterization of cement specimens are mechanical properties and porosity. This work is carried out at the Ispra Establishment of the Joint Research Centre in the scope of the Radioactive Waste Management programme. A commercial Mercury Intrusion Porosimeter was modified in an attempt to improve the performance of the instrument and to provide fast processing of the recorded values: pressure-volume of pores. The dead volume of the instrument was reduced and the possibility of leakage from the moving parts eliminated. In addition, the modification allows an improvement of data acquisition thus increasing data accuracy and reproducibility. In order to test the improved performance of the modified instrument, physical characterizations of cement forms were carried out. Experimental procedures and results are reported

  13. Preconcentration of trace amounts of lead in water samples with cetyltrimethylammonium bromide coated magnetite nanoparticles and its determination by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Mohammad Faraji

    2016-11-01

    Full Text Available A sensitive and simple magnetic solid phase extraction procedure was presented for the preconcentration of lead ions in environmental water samples. In the present study, lead ions form complexes with 1-(2-pyridilazo-2-naphthol reagent (PAN in basic medium, and then are quantitatively extracted to the surface of cetyltrimethylammonium bromide (CTAB-coated magnetite nanoparticles (Fe3O4 NPs. After magnetic separation of adsorbent, the adsorbent was eluted with 0.5% (v/v HCl in methanol prior to its analysis by flame atomic absorption spectrometry (FAAS. The pH of sample, concentrations of PAN, amounts of CTAB and Fe3O4 NPs, sample volume and desorption conditions were optimized. Under optimum conditions, the calibration curve was linear in the range of 0.05–100 ng mL−1 with R2 = 0.9996. Detection and quantification limits of the proposed method were 0.005 and 0.05 ng mL−1, respectively. Enhancement factor of 1050 was achieved using this method to extract 1000 mL of different environmental water samples. Compared with conventional solid phase extraction methods, the advantages of this method still include easy preparation of sorbents, short times of sample pre-treatment, high extraction yield, and high breakthrough volume. It shows great analytical potential in preconcentration of lead from large volume water samples.

  14. Spatial and temporal variation of residence time and storage volume of subsurface water evaluated by multi-tracers approach in mountainous headwater catchments

    Science.gov (United States)

    Tsujimura, Maki; Yano, Shinjiro; Abe, Yutaka; Matsumoto, Takehiro; Yoshizawa, Ayumi; Watanabe, Ysuhito; Ikeda, Koichi

    2015-04-01

    Headwater catchments in mountainous region are the most important recharge area for surface and subsurface waters, additionally time and stock information of the water is principal to understand hydrological processes in the catchments. However, there have been few researches to evaluate variation of residence time and storage volume of subsurface water in time and space at the mountainous headwaters especially with steep slope. We performed an investigation on age dating and estimation of storage volume using simple water budget model in subsurface water with tracing of hydrological flow processes in mountainous catchments underlain by granite, Paleozoic and Tertiary, Yamanashi and Tsukuba, central Japan. We conducted hydrometric measurements and sampling of spring, stream and ground waters in high-flow and low-flow seasons from 2008 through 2012 in the catchments, and CFCs, stable isotopic ratios of oxygen-18 and deuterium, inorganic solute constituent concentrations were determined on all water samples. Residence time of subsurface water ranged from 11 to 60 years in the granite catchments, from 17 to 32 years in the Paleozoic catchments, from 13 to 26 years in the Tertiary catchments, and showed a younger age during the high-flow season, whereas it showed an older age in the low-flow season. Storage volume of subsurface water was estimated to be ranging from 10 ^ 4 to 10 ^ 6 m3 in the granite catchments, from 10 ^ 5 to 10 ^ 7 m3 in the Paleozoic catchments, from 10 ^ 4 to 10 ^ 6 m3 in the Tertiary catchments. In addition, seasonal change of storage volume in the granite catchments was the highest as compared with those of the Paleozoic and the Tertiary catchments. The results suggest that dynamic change of hydrological process seems to cause a larger variation of the residence time and storage volume of subsurface water in time and space in the granite catchments, whereas higher groundwater recharge rate due to frequent fissures or cracks seems to cause larger

  15. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    Science.gov (United States)

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and

  16. Determination of pyridine in soil and water samples of a polluted area

    International Nuclear Information System (INIS)

    Peters, R.J.B.; Renesse van Duivenbode, J.A.D. van

    1994-01-01

    A method for the analyses of pyridine in environmental samples is described. For soil samples a distillation procedure followed by an extraction, an acidic extraction or a Soxhlet extraction can be used. For water samples a distillation procedure followed by extraction can be employed. Deuterated pyridine is used as an internal standard and the extracts are analyzed by GC-MS. The recoveries of the methods are higher than 80%; the detection limits for pyridine are 0.01 mg/kg for soil samples and 0.2 μg/l for water samples. (orig.)

  17. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    Science.gov (United States)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  18. Volume fraction calculation in multiphase system such as oil-water-gas using neutron

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Robson; Brandao, Luis E.B.; Salgado, Cesar Marques; Pereira, Claudio M.N.A. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mails: robson@ien.gov.br; brandao@ien.gov.br; otero@ien.gov.br; cmnap@ien.gov.br; Schirru, Roberto; Silva, Ademir Xavier da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mails: schirru@lmp.ufrj.br; ademir@con.ufrj.br

    2007-07-01

    Multi-phase flows are common in diverse industrial sectors and the attainment of the volume fraction of each element that composes the flow system presents difficulties for the engineering process, therefore, to determine them is very important. In this work is presented methodology for determination of volume fractions in annular three-phase flow systems, such as oil-water-gas, based on the use of nuclear techniques and artificial intelligence. Using the principle of the fast-neutron transmission/scattering, come from an isotopic {sup 241}Am-Be source, and two point detectors, is gotten measured that they are influenced by the variations of the volume fractions of each phase present in the flow. An artificial neural network is trained to correlate such measures with the respective volume fractions. In order to get the data for training of the artificial neural network without necessity to carry through experiments, MCNP-X code is used, that simulates computational of the neutrons transport. The methodology is sufficiently advantageous, therefore, allows to develop a measurement system capable to determine the fractions of the phases (oil-water-gas), with proper requirements of each petroliferous installation and with national technology contributing, possibly, with reduction of costs and increase of productivity. (author)

  19. Volume fraction calculation in multiphase system such as oil-water-gas using neutron

    International Nuclear Information System (INIS)

    Ramos, Robson; Brandao, Luis E.B.; Salgado, Cesar Marques; Pereira, Claudio M.N.A.; Schirru, Roberto; Silva, Ademir Xavier da

    2007-01-01

    Multi-phase flows are common in diverse industrial sectors and the attainment of the volume fraction of each element that composes the flow system presents difficulties for the engineering process, therefore, to determine them is very important. In this work is presented methodology for determination of volume fractions in annular three-phase flow systems, such as oil-water-gas, based on the use of nuclear techniques and artificial intelligence. Using the principle of the fast-neutron transmission/scattering, come from an isotopic 241 Am-Be source, and two point detectors, is gotten measured that they are influenced by the variations of the volume fractions of each phase present in the flow. An artificial neural network is trained to correlate such measures with the respective volume fractions. In order to get the data for training of the artificial neural network without necessity to carry through experiments, MCNP-X code is used, that simulates computational of the neutrons transport. The methodology is sufficiently advantageous, therefore, allows to develop a measurement system capable to determine the fractions of the phases (oil-water-gas), with proper requirements of each petroliferous installation and with national technology contributing, possibly, with reduction of costs and increase of productivity. (author)

  20. Water quality monitoring: A comparative case study of municipal and Curtin Sarawak's lake samples

    Science.gov (United States)

    Anand Kumar, A.; Jaison, J.; Prabakaran, K.; Nagarajan, R.; Chan, Y. S.

    2016-03-01

    In this study, particle size distribution and zeta potential of the suspended particles in municipal water and lake surface water of Curtin Sarawak's lake were compared and the samples were analysed using dynamic light scattering method. High concentration of suspended particles affects the water quality as well as suppresses the aquatic photosynthetic systems. A new approach has been carried out in the current work to determine the particle size distribution and zeta potential of the suspended particles present in the water samples. The results for the lake samples showed that the particle size ranges from 180nm to 1345nm and the zeta potential values ranges from -8.58 mV to -26.1 mV. High zeta potential value was observed in the surface water samples of Curtin Sarawak's lake compared to the municipal water. The zeta potential values represent that the suspended particles are stable and chances of agglomeration is lower in lake water samples. Moreover, the effects of physico-chemical parameters on zeta potential of the water samples were also discussed.

  1. Expanding the calculation of activation volumes: Self-diffusion in liquid water

    Science.gov (United States)

    Piskulich, Zeke A.; Mesele, Oluwaseun O.; Thompson, Ward H.

    2018-04-01

    A general method for calculating the dependence of dynamical time scales on macroscopic thermodynamic variables from a single set of simulations is presented. The approach is applied to the pressure dependence of the self-diffusion coefficient of liquid water as a particularly useful illustration. It is shown how the activation volume associated with diffusion can be obtained directly from simulations at a single pressure, avoiding approximations that are typically invoked.

  2. The (water + acetonitrile) mixture revisited: A new approach for calculating partial molar volumes

    International Nuclear Information System (INIS)

    Carmen Grande, Maria del; Julia, Jorge Alvarez; Barrero, Carmen R.; Marschoff, Carlos M.; Bianchi, Hugo L.

    2006-01-01

    Density and viscosity of (water + acetonitrile) mixtures were measured over the whole composition range at the temperatures: (298.15, 303.15, 308.15, 313.15, and 318.15) K. A new mathematical approach was developed which allows the calculation of the derivatives of density with respect to composition avoiding the appearance of local discontinuities. Thus, reliable partial molar volumes and thermal expansion coefficients were obtained

  3. Water stress from high-volume hydraulic fracturing potentially threatens aquatic biodiversity and ecosystem services in Arkansas, United States

    Science.gov (United States)

    Entrekin, Sally; Trainor, Anne; Saiers, James; Patterson, Lauren; Maloney, Kelly O.; Fargione, Joseph; Kiesecker, Joseph M.; Baruch-Mordo, Sharon; Konschnik, Katherine E.; Wiseman, Hannah; Nicot, Jean-Philippe; Ryan, Joseph N.

    2018-01-01

    Demand for high-volume, short duration water withdrawals could create water stress to aquatic organisms in Fayetteville Shale streams sourced for hydraulic fracturing fluids. We estimated potential water stress using permitted water withdrawal volumes and actual water withdrawals compared to monthly median, low, and high streamflows. Risk for biological stress was considered at 20% of long-term median and 10% of high- and low-flow thresholds. Future well build-out projections estimated potential for continued stress. Most water was permitted from small, free-flowing streams and “frack” ponds (dammed streams). Permitted 12-h pumping volumes exceeded median streamflow at 50% of withdrawal sites in June, when flows were low. Daily water usage, from operator disclosures, compared to median streamflow showed possible water stress in 7–51% of catchments from June–November, respectively. If 100% of produced water was recycled, per-well water use declined by 25%, reducing threshold exceedance by 10%. Future water stress was predicted to occur in fewer catchments important for drinking water and species of conservation concern due to the decline in new well installations and increased use of recycled water. Accessible and precise withdrawal and streamflow data are critical moving forward to assess and mitigate water stress in streams that experience high-volume withdrawals.

  4. Water Stress from High-Volume Hydraulic Fracturing Potentially Threatens Aquatic Biodiversity and Ecosystem Services in Arkansas, United States.

    Science.gov (United States)

    Entrekin, Sally; Trainor, Anne; Saiers, James; Patterson, Lauren; Maloney, Kelly; Fargione, Joseph; Kiesecker, Joseph; Baruch-Mordo, Sharon; Konschnik, Katherine; Wiseman, Hannah; Nicot, Jean-Philippe; Ryan, Joseph N

    2018-02-20

    Demand for high-volume, short duration water withdrawals could create water stress to aquatic organisms in Fayetteville Shale streams sourced for hydraulic fracturing fluids. We estimated potential water stress using permitted water withdrawal volumes and actual water withdrawals compared to monthly median, low, and high streamflows. Risk for biological stress was considered at 20% of long-term median and 10% of high- and low-flow thresholds. Future well build-out projections estimated potential for continued stress. Most water was permitted from small, free-flowing streams and "frack" ponds (dammed streams). Permitted 12-h pumping volumes exceeded median streamflow at 50% of withdrawal sites in June, when flows were low. Daily water usage, from operator disclosures, compared to median streamflow showed possible water stress in 7-51% of catchments from June-November, respectively. If 100% of produced water was recycled, per-well water use declined by 25%, reducing threshold exceedance by 10%. Future water stress was predicted to occur in fewer catchments important for drinking water and species of conservation concern due to the decline in new well installations and increased use of recycled water. Accessible and precise withdrawal and streamflow data are critical moving forward to assess and mitigate water stress in streams that experience high-volume withdrawals.

  5. Characterization of Volume F Trash from Four Recent STS Missions: Weights, Categorization, Water Content

    Science.gov (United States)

    Strayer, Richard F.; Hummerick, Mary E.; Richards, Jeffrey T.; McCoy, LaShelle E.; Roberts, Michael S.; Wheeler, Raymond M.

    2011-01-01

    The fate of space-generated solid wastes, including trash, for future missions is under consideration by NASA. Several potential treatment options are under consideration and active technology development. Potential fates for space-generated solid wastes are: Storage without treatment; storage after treatment(s) including volume reduction, water recovery, sterilization, and recovery plus recycling of waste materials. Recycling might be important for partial or full closure scenarios because of the prohibitive costs associated with resupply of consumable materials. For this study, we determined the composition of trash returned from four recent STS missions. The trash material was 'Volume F' trash and other trash, in large zip-lock bags, that accompanied the Volume F trash. This is the first of two submitted papers on these wastes. This one will cover trash content, weight and water content. The other will report on the microbial Characterization of this trash. STS trash was usually made available within 2 days of landing at KSC. The Volume F bag was weighed, opened and the contents were catalogued and placed into one of the following categories: food waste (and containers), drink containers, personal hygiene items - including EVA maximum absorbent garments (MAGs)and Elbow packs (daily toilet wipes, etc), paper, and packaging materials - plastic firm and duct tape. Trash generation rates for the four STS missions: Total wet trash was 0.602 plus or minus 0.089 kg(sub wet) crew(sup -1) d(sup -1) containing about 25% water at 0.154 plus or minus 0.030 kg(sub water) crew(sup -1) d(sup -1) (avg plus or minus stdev). Cataloguing by category: personal hygiene wastes accounted for 50% of the total trash and 69% of the total water for the four missions; drink items were 16% of total weight and 16% water; food wastes were 22% of total weight and 15% of the water; office waste and plastic film were 2% and 11% of the total waste and did not contain any water. The results can be

  6. Aerobic fitness relates to learning on a virtual morris water task and hippocampal volume in adolescents

    Science.gov (United States)

    Herting, Megan M.; Nagel, Bonnie J.

    2012-01-01

    In rodents, exercise increases hippocampal neurogenesis and allows for better learning and memory performance on water maze tasks. While exercise has also been shown to be beneficial for the brain and behavior in humans, no study has examined how exercise impacts spatial learning using a directly translational water maze task, or if these relationships exist during adolescence – a developmental period which the animal literature has shown to be especially vulnerable to exercise effects. In this study, we investigated the influence of aerobic fitness on hippocampal size and subsequent learning and memory, including visuospatial memory using a human analogue of the Morris Water Task, in 34 adolescents. Results showed that higher aerobic fitness predicted better learning on the virtual Morris Water Task and larger hippocampal volumes. No relationship between virtual Morris Water Task memory recall and aerobic fitness was detected. Aerobic fitness, however, did not relate to global brain volume, or verbal learning, which might suggest some specificity of the influence of aerobic fitness on the adolescent brain. This study provides a direct translational approach to the existing animal literature on exercise, as well as adds to the sparse research that exists on how aerobic exercise impacts the developing human brain and memory. PMID:22610054

  7. Aerobic fitness relates to learning on a virtual Morris Water Task and hippocampal volume in adolescents.

    Science.gov (United States)

    Herting, Megan M; Nagel, Bonnie J

    2012-08-01

    In rodents, exercise increases hippocampal neurogenesis and allows for better learning and memory performance on water maze tasks. While exercise has also been shown to be beneficial for the brain and behavior in humans, no study has examined how exercise impacts spatial learning using a directly translational water maze task, or if these relationships exist during adolescence--a developmental period which the animal literature has shown to be especially vulnerable to exercise effects. In this study, we investigated the influence of aerobic fitness on hippocampal size and subsequent learning and memory, including visuospatial memory using a human analogue of the Morris Water Task, in 34 adolescents. Results showed that higher aerobic fitness predicted better learning on the virtual Morris Water Task and larger hippocampal volumes. No relationship between virtual Morris Water Task memory recall and aerobic fitness was detected. Aerobic fitness, however, did not relate to global brain volume or verbal learning, which might suggest some specificity of the influence of aerobic fitness on the adolescent brain. This study provides a direct translational approach to the existing animal literature on exercise, as well as adds to the sparse research that exists on how aerobic exercise impacts the developing human brain and memory. Published by Elsevier B.V.

  8. Pesticide residues analysis in water samples of Nagarpur and Saturia Upazila, Bangladesh

    Science.gov (United States)

    Hasanuzzaman, M.; Rahman, M. A.; Islam, M. S.; Salam, M. A.; Nabi, M. R.

    2018-03-01

    Pesticides used to protect the crops from pest attack in the agricultural fields pose harmful effect to the non-target organisms such as human and many other aquatic and terrestrial organisms either directly or indirectly through food chain. The present study was conducted to monitor a total of seven pesticide residues under organochlorine, organophosphorus and carbamate pesticides in three different sources of pond water, paddy field water and tube-well water from Nagarpur Upazila and paddy field water in the company of Dhaleshwari and Gazikhali river water from Saturia Upazila, Bangladesh. A total of 40 water samples were analyzed using high-performance liquid chromatography equipped with ultraviolet detector. Among the organophosphorus pesticides, diazinon was detected in eight water samples at a concentration ranging from 4.11 to 257.91 μg/l whereas, malathion was detected only in one water sample at a concentration of 84.64 μg/l and chlorpyrifos pesticide was also detected only in one water sample and the concentration was 37.3 μg/l. Trace amount of carbaryl was identified but it was below the detection limit. None of the tested water samples was found to be contaminated with DDT or its metabolites (DDE and DDD). The water samples contaminated with the suspected pesticides were above the acceptable limit except for the fish pond samples of Sahabatpur and Dubaria union. To control the misuse of pesticides and to reduce the possible health risk, appropriate control systems of pests such as integrated pest management system should be implemented immediately by the authorities of the country.

  9. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  10. Presence of pesticide residues in water, sediment and biological samples taken from aquatic environments in Honduras

    International Nuclear Information System (INIS)

    Meyer, D.E.

    1999-01-01

    The objective of this study was to detect the presence of persistent pesticides in water, sediment and biological samples taken from aquatic environments in Honduras during the period 1995-98. Additionally, the LC 50 for 2 fungicides and 2 insecticides on post-larval Penaeus vannamei was determined in static water bioassays. A total of 80 water samples, 16 sediment samples and 7 biological samples (fish muscle tissue) were analyzed for detection of organochlorine and organophosphate pesticide residues. The results of sample analyses indicate a widespread contamination of Honduran continental and coastal waters with organochlorine pesticides. Most detections were of low ( 50 values and were therefore found to be much more toxic to the post-larval shrimp than the fungicides tridemorph and propiconazole. (author)

  11. Sampling designs and methods for estimating fish-impingement losses at cooling-water intakes

    International Nuclear Information System (INIS)

    Murarka, I.P.; Bodeau, D.J.

    1977-01-01

    Several systems for estimating fish impingement at power plant cooling-water intakes are compared to determine the most statistically efficient sampling designs and methods. Compared to a simple random sampling scheme the stratified systematic random sampling scheme, the systematic random sampling scheme, and the stratified random sampling scheme yield higher efficiencies and better estimators for the parameters in two models of fish impingement as a time-series process. Mathematical results and illustrative examples of the applications of the sampling schemes to simulated and real data are given. Some sampling designs applicable to fish-impingement studies are presented in appendixes

  12. Partial molar volume of n-alcohols at infinite dilution in water calculated by means of scaled particle theory.

    Science.gov (United States)

    Graziano, Giuseppe

    2006-04-07

    The partial molar volume of n-alcohols at infinite dilution in water is smaller than the molar volume in the neat liquid phase. It is shown that the formula for the partial molar volume at infinite dilution obtained from the scaled particle theory equation of state for binary hard sphere mixtures is able to reproduce in a satisfactory manner the experimental data over a large temperature range. This finding implies that the packing effects play the fundamental role in determining the partial molar volume at infinite dilution in water also for solutes, such as n-alcohols, forming H bonds with water molecules. Since the packing effects in water are largely related to the small size of its molecules, the latter feature is the ultimate cause of the decrease in partial molar volume associated with the hydrophobic effect.

  13. A simple bubbling system for measuring radon (222Rn) gas concentrations in water samples based on the high solubility of radon in olive oil.

    Science.gov (United States)

    Al-Azmi, D; Snopek, B; Sayed, A M; Domanski, T

    2004-01-01

    Based on the different levels of solubility of radon gas in organic solvents and water, a bubbling system has been developed to transfer radon gas, dissolving naturally in water samples, to an organic solvent, i.e. olive oil, which is known to be a good solvent of radon gas. The system features the application of a fixed volume of bubbling air by introducing a fixed volume of water into a flask mounted above the system, to displace an identical volume of air from an air cylinder. Thus a gravitational flow of water is provided without the need for pumping. Then, the flushing air (radon-enriched air) is directed through a vial containing olive oil, to achieve deposition of the radon gas by another bubbling process. Following this, the vial (containing olive oil) is measured by direct use of gamma ray spectrometry, without the need of any chemical or physical processing of the samples. Using a standard solution of 226Ra/222Rn, a lowest measurable concentration (LMC) of radon in water samples of 9.4 Bq L(-1) has been achieved (below the maximum contaminant level of 11 Bq L(-1)).

  14. Characterization of the intragranular water regime within subsurface sediments: pore volume, surface area, and mass transfer limitations

    Science.gov (United States)

    Hay, Michael B.; Stoliker, Deborah L.; Davis, James A.; Zachara, John M.

    2011-01-01

    Although "intragranular" pore space within grain aggregates, grain fractures, and mineral surface coatings may contain a relatively small fraction of the total porosity within a porous medium, it often contains a significant fraction of the reactive surface area, and can thus strongly affect the transport of sorbing solutes. In this work, we demonstrate a batch experiment procedure using tritiated water as a high-resolution diffusive tracer to characterize the intragranular pore space. The method was tested using uranium-contaminated sediments from the vadose and capillary fringe zones beneath the former 300A process ponds at the Hanford site (Washington). Sediments were contacted with tracers in artificial groundwater, followed by a replacement of bulk solution with tracer-free groundwater and the monitoring of tracer release. From these data, intragranular pore volumes were calculated and mass transfer rates were quantified using a multirate first-order mass transfer model. Tritium-hydrogen exchange on surface hydroxyls was accounted for by conducting additional tracer experiments on sediment that was vacuum dried after reaction. The complementary ("wet" and "dry") techniques allowed for the simultaneous determination of intragranular porosity and surface area using tritium. The Hanford 300A samples exhibited intragranular pore volumes of ~1% of the solid volume and intragranular surface areas of ~20%–35% of the total surface area. Analogous experiments using bromide ion as a tracer yielded very different results, suggesting very little penetration of bromide into the intragranular porosity.

  15. Estimation of uranium in drinking water samples collected from different locations across Tarapur, India

    International Nuclear Information System (INIS)

    Dusane, C.B.; Maity, Sukanta; Sahu, S.K.; Pandit, G.G.

    2015-01-01

    In this study, drinking water samples were collected from different locations across Tarapur, India for screening uranium contents. Uranium concentrations were determined by differential pulse adsorptive stripping voltammetry (DPASV). Uranium concentration in water samples varied in a wide range from 0.6-7.9 μg L -1 . Results were compared with the international water quality guidelines World Health Organization (WHO, 2011) and were found within the permissible limit. Results were also compared with the safe limit values for drinking water recommended by national organization like Atomic Energy Regulatory Board (AERB). (author)

  16. Evaluation of the Purge Water Management System (PWMS) monitor well sampling technology at SRS

    International Nuclear Information System (INIS)

    Hiergesell, R.A.; Cardoso-Neto, J.E.; Williams, D.W.

    1997-01-01

    Due to the complex issues surrounding Investigation Derived Waste (IDW) at SRS, the Environmental Restoration Division has been exploring new technologies to deal with the purge water generated during monitoring well sampling. Standard procedures for sampling generates copious amounts of purge water that must be managed as hazardous waste, when containing hazardous and/or radiological contaminants exceeding certain threshold levels. SRS has obtained Regulator approval to field test an innovative surface release prevention mechanism to manage purge water. This mechanism is referred to as the Purge Water Management System (PWMS) and consists of a collapsible bladder situated within a rigid metal tank

  17. Uranium and thorium determination in water samples taken along River Kura

    International Nuclear Information System (INIS)

    Ahmadov, M.M.; Ibadov, N.A.; Safarova, K.S.; Humbatov, F.Y.; Suleymanov, B.A.

    2014-01-01

    Full text : In the present investigation, uranium and thorium concentration in rivers water of Azerbaijan has been measured using inductively coupled plasma mass spectrometry. The Agilent 7700x series ICP-MS applied for analysis of water samples. This method is based on direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma plasma mass spectrometer. Uranium and thorium was determined at the mass mass numbers of 238 and 232 respectively using Bi-209 as internal standard. The main purpose of the study is to measure the level of uranium and thorium in water samples taken along river Kura

  18. Estimating an appropriate sampling frequency for monitoring ground water well contamination

    International Nuclear Information System (INIS)

    Tuckfield, R.C.

    1994-01-01

    Nearly 1,500 ground water wells at the Savannah River Site (SRS) are sampled quarterly to monitor contamination by radionuclides and other hazardous constituents from nearby waste sites. Some 10,000 water samples were collected in 1993 at a laboratory analysis cost of $10,000,000. No widely accepted statistical method has been developed, to date, for estimating a technically defensible ground water sampling frequency consistent and compliant with federal regulations. Such a method is presented here based on the concept of statistical independence among successively measured contaminant concentrations in time

  19. Selective trace enrichment of chlorotriazine pesticides from natural waters and sediment samples using terbuthylazine molecularly imprinted polymers

    Science.gov (United States)

    Ferrer, I.; Lanza, F.; Tolokan, A.; Horvath, V.; Sellergren, B.; Horvai, G.; Barcelo, D.

    2000-01-01

    Two molecularly imprinted polymers were synthesized using either dichloromethane or toluene as the porogen and terbuthylazine as the template and were used as solid-phase extraction cartridges for the enrichment of six chlorotriazines (deisopropylatrazine, deethylatrazine, simazine, atrazine, propazine, and terbuthylazine) in natural water and sediment samples. The extracted samples were analyzed by liquid chromatography/diode array detection (LC/DAD). Several washing solvents, as well as different volumes, were tested for their ability to remove the matrix components nonspecifically adsorbed on the sorbents. This cleanup step was shown to be of prime importance to the successful extraction of the pesticides from the aqueous samples. The optimal analytical conditions were obtained when the MIP imprinted using dichloromethane was the sorbent, 2 mL of dichloromethane was used in the washing step, and the preconcentrated analytes were eluted with 8 mL of methanol. The recoveries were higher than 80% for all the chlorotriazines except for propazine (53%) when 50- or 100-mL groundwater samples, spiked at 1 ??g/L level, were analyzed. The limits of detection varied from 0.05 to 0.2 ??g/L when preconcentrating a 100-mL groundwater sample. Natural sediment samples from the Ebre Delta area (Tarragona, Spain) containing atrazine and deethylatrazine were Soxhlet extracted and analyzed by the methodology developed in this work. No significant interferences from the sample matrix were noticed, thus indicating good selectivity of the MIP sorbents used.

  20. Environmental report 1995. Volume 2

    International Nuclear Information System (INIS)

    Harrach, R.J.; Failor, R.A.; Gallegos, G.M.

    1996-09-01

    This is Volume 2 of the Lawrence Livermore National Laboratory's (LLNL's) annual Environmental Report 1995. This volume is intended to support summary data from Volume 1 and is essentially a detailed data report that provides additional data points, where applicable. Some summary data are also included in Volume 2, and more detailed accounts are given of sample collection and analytical methods. Volume 2 includes information in eight chapters on monitoring of air, air effluent, sewage, surface water, ground water, soil and sediment, vegetation and foodstuff, and environmental radiation, as well as three chapters on ground water protection, compliance self-monitoring and quality assurance

  1. Improved prediction of octanol-water partition coefficients from liquid-solute water solubilities and molar volumes

    Science.gov (United States)

    Chiou, C.T.; Schmedding, D.W.; Manes, M.

    2005-01-01

    A volume-fraction-based solvent-water partition model for dilute solutes, in which the partition coefficient shows a dependence on solute molar volume (V??), is adapted to predict the octanol-water partition coefficient (K ow) from the liquid or supercooled-liquid solute water solubility (Sw), or vice versa. The established correlation is tested for a wide range of industrial compounds and pesticides (e.g., halogenated aliphatic hydrocarbons, alkylbenzenes, halogenated benzenes, ethers, esters, PAHs, PCBs, organochlorines, organophosphates, carbamates, and amidesureas-triazines), which comprise a total of 215 test compounds spanning about 10 orders of magnitude in Sw and 8.5 orders of magnitude in Kow. Except for phenols and alcohols, which require special considerations of the Kow data, the correlation predicts the Kow within 0.1 log units for most compounds, much independent of the compound type or the magnitude in K ow. With reliable Sw and V data for compounds of interest, the correlation provides an effective means for either predicting the unavailable log Kow values or verifying the reliability of the reported log Kow data. ?? 2005 American Chemical Society.

  2. Neutron multicounter detector for investigation of content and spatial distribution of fission materials in large volume samples

    International Nuclear Information System (INIS)

    Swiderska-Kowalczyk, M.; Starosta, W.; Zoltowski, T.

    1998-01-01

    The experimental device is a neutron coincidence well counter. It can be applied for passive assay of fissile - especially for plutonium bearing - materials. It consist of a set of 3 He tubes placed inside a polyethylene moderator; outputs from the tubes, first processed by preamplifier/amplifier/discriminator circuits, are then analysed using neutron correlator connected with a PC, and correlation techniques implemented in software. Such a neutron counter allows for determination of plutonium mass ( 240 Pu effective mass) in nonmultiplying samples having fairly big volume (up to 0.14 m 3 ). For determination of neutron sources distribution inside the sample, the heuristic methods based on hierarchical cluster analysis are applied. As an input parameters, amplitudes and phases of two-dimensional Fourier transformation of the count profiles matrices for known point sources distributions and for the examined samples, are taken. Such matrices are collected by means of sample scanning by detection head. During clustering process, counts profiles for unknown samples fitted into dendrograms using the 'proximity' criterion of the examined sample profile to standard samples profiles. Distribution of neutron sources in an examined sample is then evaluated on the basis of comparison with standard sources distributions. (author)

  3. Monitoring the aftermath of Flint drinking water contamination crisis: Another case of sampling bias?

    Science.gov (United States)

    Goovaerts, Pierre

    2017-07-15

    The delay in reporting high levels of lead in Flint drinking water, following the city's switch to the Flint River as its water supply, was partially caused by the biased selection of sampling sites away from the lead pipe network. Since Flint returned to its pre-crisis source of drinking water, the State has been monitoring water lead levels (WLL) at selected "sentinel" sites. In a first phase that lasted two months, 739 residences were sampled, most of them bi-weekly, to determine the general health of the distribution system and to track temporal changes in lead levels. During the same period, water samples were also collected through a voluntary program whereby concerned citizens received free testing kits and conducted sampling on their own. State officials relied on the former data to demonstrate the steady improvement in water quality. A recent analysis of data collected by voluntary sampling revealed, however, an opposite trend with lead levels increasing over time. This paper looks at potential sampling bias to explain such differences. Although houses with higher WLL were more likely to be sampled repeatedly, voluntary sampling turned out to reproduce fairly well the main characteristics (i.e. presence of lead service lines (LSL), construction year) of Flint housing stock. State-controlled sampling was less representative; e.g., sentinel sites with LSL were mostly built between 1935 and 1950 in lower poverty areas, which might hamper our ability to disentangle the effects of LSL and premise plumbing (lead fixtures and pipes present within old houses) on WLL. Also, there was no sentinel site with LSL in two of the most impoverished wards, including where the percentage of children with elevated blood lead levels tripled following the switch in water supply. Correcting for sampling bias narrowed the gap between sampling programs, yet overall temporal trends are still opposite. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Understanding the origin and evolution of water in the Moon through lunar sample studies.

    Science.gov (United States)

    Anand, Mahesh; Tartèse, Romain; Barnes, Jessica J

    2014-09-13

    A paradigm shift has recently occurred in our knowledge and understanding of water in the lunar interior. This has transpired principally through continued analysis of returned lunar samples using modern analytical instrumentation. While these recent studies have undoubtedly measured indigenous water in lunar samples they have also highlighted our current limitations and some future challenges that need to be overcome in order to fully understand the origin, distribution and evolution of water in the lunar interior. Another exciting recent development in the field of lunar science has been the unambiguous detection of water or water ice on the surface of the Moon through instruments flown on a number of orbiting spacecraft missions. Considered together, sample-based studies and those from orbit strongly suggest that the Moon is not an anhydrous planetary body, as previously believed. New observations and measurements support the possibility of a wet lunar interior and the presence of distinct reservoirs of water on the lunar surface. Furthermore, an approach combining measurements of water abundance in lunar samples and its hydrogen isotopic composition has proved to be of vital importance to fingerprint and elucidate processes and source(s) involved in giving rise to the lunar water inventory. A number of sources are likely to have contributed to the water inventory of the Moon ranging from primordial water to meteorite-derived water ice through to the water formed during the reaction of solar wind hydrogen with the lunar soil. Perhaps two of the most striking findings from these recent studies are the revelation that at least some portions of the lunar interior are as water-rich as some Mid-Ocean Ridge Basalt source regions on Earth and that the water in the Earth and the Moon probably share a common origin. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  5. Design, analysis, and interpretation of field quality-control data for water-sampling projects

    Science.gov (United States)

    Mueller, David K.; Schertz, Terry L.; Martin, Jeffrey D.; Sandstrom, Mark W.

    2015-01-01

    The process of obtaining and analyzing water samples from the environment includes a number of steps that can affect the reported result. The equipment used to collect and filter samples, the bottles used for specific subsamples, any added preservatives, sample storage in the field, and shipment to the laboratory have the potential to affect how accurately samples represent the environment from which they were collected. During the early 1990s, the U.S. Geological Survey implemented policies to include the routine collection of quality-control samples in order to evaluate these effects and to ensure that water-quality data were adequately representing environmental conditions. Since that time, the U.S. Geological Survey Office of Water Quality has provided training in how to design effective field quality-control sampling programs and how to evaluate the resultant quality-control data. This report documents that training material and provides a reference for methods used to analyze quality-control data.

  6. Ionizing radiation as optimization method for aluminum detection from drinking water samples

    International Nuclear Information System (INIS)

    Bazante-Yamguish, Renata; Geraldo, Aurea Beatriz C.; Moura, Eduardo; Manzoli, Jose Eduardo

    2013-01-01

    The presence of organic compounds in water samples is often responsible for metal complexation; depending on the analytic method, the organic fraction may dissemble the evaluation of the real values of metal concentration. Pre-treatment of the samples is advised when organic compounds are interfering agents, and thus sample mineralization may be accomplished by several chemical and/or physical methods. Here, the ionizing radiation was used as an advanced oxidation process (AOP), for sample pre-treatment before the analytic determination of total and dissolved aluminum by ICP-OES in drinking water samples from wells and spring source located at Billings dam region. Before irradiation, the spring source and wells' samples showed aluminum levels of 0.020 mg/l and 0.2 mg/l respectively; after irradiation, both samples showed a 8-fold increase of aluminum concentration. These results are discussed considering other physical and chemical parameters and peculiarities of sample sources. (author)

  7. Monitoring of gross beta radioactivities on water sample environment in the surrounding of kartini reactor at 2011

    International Nuclear Information System (INIS)

    Siswanti; Munandar, A. Aris

    2013-01-01

    Measurement of gross beta radioactivities on water environment were done in the PTAPB BATAN has a goal for routine monitoring, with the result that fill RPL has been made and the result equivalented with quality standard were decided by BAPETEN. The water sample taken as much as 2 liter at 18 area were definited on radius 100 m to 5000 m in the surrounding of kartini reactor, vaporin on electric stove till the volume been ± 10 ml, and than pick out to the aluminium planset and drying on hot plate. Sample in the plancet were counted with a Low Background Counter (LBC) for 30 minutes and accounted of gross beta radioactivity water system. The result of gross beta radioactivity water environment at 2011 has a lowest 009, ± 0,06 Bq/I on Tambak Bayan area at june and in the Janti area highest 0,39 ± 0,08 Bq/ at December. The result still under of quality standard were decided by SK BAPETEN. No. 02/Ka- BAPETEN/V-99 is 0,4 Bq/I. (author)

  8. Nuclear waste calorimeter for very large drums with 385 litres sample volume

    Energy Technology Data Exchange (ETDEWEB)

    Jossens, G.; Mathonat, C. [SETARAM Instrumentation, Caluire (France); Bachelet, F. [CEA Valduc, Is sur Tille (France)

    2015-03-15

    Calorimetry is a very precise and well adapted tool for the classification of drums containing nuclear waste material depending on their level of activities (low, medium, high). A new calorimeter has been developed by SETARAM Instrumentation and the CEA Valduc in France. This new calorimeter is designed for drums having a volume bigger than 100 liters. It guarantees high operator safety by optimizing drum handling and air circulation for cooling, and optimized software for direct measurement of the quantity of nuclear material. The LVC1380 calorimeter makes it possible to work over the range 10 to 3000 mW, which corresponds to approximately 0.03 to 10 g of tritium or 3 to 955 g of {sup 241}Pu in a volume up to 385 liters. This calorimeter is based on the heat flow measurement using Peltier elements which surround the drum in the 3 dimensions and therefore measure all the heat coming from the radioactive stuff whatever its position inside the drum. Calorimeter's insulating layers constitute a thermal barrier designed to filter disturbances until they represent less than 0.001 Celsius degrees and to eliminate long term disturbances associated, for example, with laboratory temperature variations between day and night. A calibration device based on Joule effect has also been designed. Measurement time has been optimized but remains long compared with other methods of measurement such as gamma spectrometry but its main asset is to have a good accuracy for low level activities.

  9. Analytical study on the determination of boron in environmental water samples

    International Nuclear Information System (INIS)

    Lopez, F.J.; Gimenez, E.; Hernandez, F.

    1993-01-01

    An analytical study on the determination of boron in environmental water samples was carried out. The curcumin and carmine standard methods were compared with the most recent Azomethine-H method in order to evaluate their analytical characteristics and feasibility for the analysis of boron in water samples. Analyses of synthetic water, ground water, sea water and waste water samples were carried out and a statistical evaluation of the results was made. The Azomethine-H method was found to be the most sensitive (detection limit 0.02 mg l -1 ) and selective (no interference of commonly occurring ions in water was observed), showing also the best precision (relative standard deviation lower than 4%). Moreover, it gave good results for all types of samples analyzed. The accuracy of this method was tested by the addition of known amounts of standard solutions to different types of water samples. The slopes of standard additions and direct calibration graphs were similar and recoveries of added boron ranged from 99 to 107%. (orig.)

  10. Estimation of uranium in different types of water and sand samples by adsorptive stripping voltammetry

    International Nuclear Information System (INIS)

    Bhalke, Sunil; Raghunath, Radha; Mishra, Suchismita; Suseela, B.; Tripathi, R.M.; Pandit, G.G.; Shukla, V.K.; Puranik, V.D.

    2005-01-01

    A method is standardized for the estimation of uranium by adsorptive stripping voltammetry using chloranilic acid (CAA) as complexing agent. The optimum parameters to get best sensitivity and good reproducibility for uranium were 60s adsorption time, pH 1.8, chloranilic acid (2x10 -4 M) and 0.002M EDTA. The peak potential under this condition was found to be -0.03 V. With these optimum parameters a sensitivity of 1.19 nA/nM uranium was observed. Detection limit for this optimum parameter was found to be 0.55 nM. This can be further improved by increasing adsorption time. Using this method, uranium was estimated in different type of water samples such as seawater, synthetic seawater, stream water, tap water, well water, bore well water and process water. This method has also been used for estimation of uranium in sand, organic solvent used for extraction of uranium from phosphoric acid and its raffinate. Sample digestion procedures used for estimation of uranium in various matrices are discussed. It has been observed from the analysis that the uranium peak potentials changes with matrix of the sample, hence, standard addition method is the best method to get reliable and accurate results. Quality assurance of the standardized method is verified by analyzing certified reference water sample from USDOE, participating intercomparison exercises and also by estimating uranium content in water samples both by differential pulse adsorptive stripping voltammetric and laser fluorimetric techniques. (author)

  11. Identification and quantification of pesticide residues in water samples of Dhamrai Upazila, Bangladesh

    Science.gov (United States)

    Hasanuzzaman, M.; Rahman, M. A.; Salam, M. A.

    2017-10-01

    Being agricultural country, different types of pesticides are widely used in Bangladesh to prevent the crop losses due to pest attack which are ultimately drain to the water bodies. The present study was conducted to identify and quantify the organochlorine (DDT, DDE and DDD), organophosphorus (malathion, diazinon and chloropyrifos) and carbamate (carbaryl) residues in water samples of different sources from Dhamrai upazila of Bangladesh using high performance liquid chromatography (HPLC) equipped with ultra violate (UV) detector. Thirty water samples from fish pond, cultivated land and tube-well were collected in winter season to analyze the pesticide residues. Among the organophosphorus pesticides, malathion was present in seven water samples ranging from 42.58 to 922.8 μg/L, whereas diazinon was detected in water sample-8 (WS-8) and the concentration was 31.5 μg/L. None of the tested water samples was found to be contaminated with chlorpyrifos, carbaryl or DDT and its metabolites (DDE and DDD). Except for a tube-well water sample, concentrations of the detected residues are above the acceptable limit for human body as assigned by different organizations. To avoid the possible health hazards, the indiscriminate application of pesticides should be restricted and various substitute products like bio-pesticide should be introduced in a broad scale as soon as possible.

  12. On-chip polarimetry for high-throughput screening of nanoliter and smaller sample volumes

    Science.gov (United States)

    Bachmann, Brian O. (Inventor); Bornhop, Darryl J. (Inventor); Dotson, Stephen (Inventor)

    2012-01-01

    A polarimetry technique for measuring optical activity that is particularly suited for high throughput screening employs a chip or substrate (22) having one or more microfluidic channels (26) formed therein. A polarized laser beam (14) is directed onto optically active samples that are disposed in the channels. The incident laser beam interacts with the optically active molecules in the sample, which slightly alter the polarization of the laser beam as it passes multiple times through the sample. Interference fringe patterns (28) are generated by the interaction of the laser beam with the sample and the channel walls. A photodetector (34) is positioned to receive the interference fringe patterns and generate an output signal that is input to a computer or other analyzer (38) for analyzing the signal and determining the rotation of plane polarized light by optically active material in the channel from polarization rotation calculations.

  13. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    Science.gov (United States)

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  14. Use of an Electronic Tongue System and Fuzzy Logic to Analyze Water Samples

    Science.gov (United States)

    Braga, Guilherme S.; Paterno, Leonardo G.; Fonseca, Fernando J.

    2009-05-01

    An electronic tongue (ET) system incorporating 8 chemical sensors was used in combination with two pattern recognition tools, namely principal component analysis (PCA) and Fuzzy logic for discriminating/classification of water samples from different sources (tap, distilled and three brands of mineral water). The Fuzzy program exhibited a higher accuracy than the PCA and allowed the ET to classify correctly 4 in 5 types of water. Exception was made for one brand of mineral water which was sometimes misclassified as tap water. On the other hand, the PCA grouped water samples in three clusters, one with the distilled water; a second with tap water and one brand of mineral water, and the third with the other two other brands of mineral water. Samples in the second and third clusters could not be distinguished. Nevertheless, close grouping between repeated tests indicated that the ET system response is reproducible. The potential use of the Fuzzy logic as the data processing tool in combination with an electronic tongue system is discussed.

  15. Determination of trace amount of lead in industrial and municipal effluent water samples based on dispersive liquid-liquid extraction

    Energy Technology Data Exchange (ETDEWEB)

    Shirkhanloo, H. [Iranian Petroleum Industry Health Research Institute, Occupational and Environmental Health Research Center, Tehran (Iran, Islamic Republic of); Sedighi, K.; Mousavi, H. Z., E-mail: hzmousavi@semnan.ac.ir [Semnan University, College of Science, Department of Chemistry, Semnan (Iran, Islamic Republic of)

    2014-10-01

    In this study, a simple, sensitive and accurate method was developed for the determination of lead ion by combining ionic liquid dispersive liquid-liquid extraction (Il-DLL E) with flame atomic absorption spectrometry. Tetraethyl thiuram disulfide (Tetd), acetone and 1-octyl-3m ethylimidazolium hexafluorophosphate [(C{sub 8}MIM) (PF{sub 6})] were used as the chelating agent, dispersive and extraction solvent, respectively. Under the optimal conditions, the calibration graph was linear in the range of 5-190 μg L{sup -1} of lead and the detection limit was 0.8 μg L{sup -1} with a sample volume of 200 ml. The proposed method was validated by the analysis of one certified reference material and applied successfully to the determination of lead in real water samples. (Author)

  16. Determination of trace amount of lead in industrial and municipal effluent water samples based on dispersive liquid-liquid extraction

    International Nuclear Information System (INIS)

    Shirkhanloo, H.; Sedighi, K.; Mousavi, H. Z.

    2014-01-01

    In this study, a simple, sensitive and accurate method was developed for the determination of lead ion by combining ionic liquid dispersive liquid-liquid extraction (Il-DLL E) with flame atomic absorption spectrometry. Tetraethyl thiuram disulfide (Tetd), acetone and 1-octyl-3m ethylimidazolium hexafluorophosphate [(C 8 MIM) (PF 6 )] were used as the chelating agent, dispersive and extraction solvent, respectively. Under the optimal conditions, the calibration graph was linear in the range of 5-190 μg L -1 of lead and the detection limit was 0.8 μg L -1 with a sample volume of 200 ml. The proposed method was validated by the analysis of one certified reference material and applied successfully to the determination of lead in real water samples. (Author)

  17. Prevalence of Cryptosporidium and Giardia lamblia in Water Samples from Jeddah and Makkah Cities

    Directory of Open Access Journals (Sweden)

    Haytham Ahmed Zakai

    2014-01-01

    Full Text Available Water contamination by Giardia lamblia and Cryptosporidium is one of the causes of diarrhoea throughout the world.  A total of 161 and 84 samples were collected from Jeddah and Makkah cities, respectively.  Each sample was concentrated by double centrifugation and the sediment was examined as a wet smear and after staining with Trichrome and Kinyoun stains.  The results showed that 56 (35% and 1 (0.62 % samples of Jeddah were positive for the oocyst of Cryptosporidium and cyst of Giardia, whereas only 21 (25% and 2 (2.4 % samples of Makkah showed positivity for oocysts and cyst of these parasites. Overall Cryptosporidium contamination in bottled water and water from filling stations was 6.8% and 17.4%, respectively. Maximum contamination for Cryptosporidium was recorded in tap water which was 51% and 25% in Jeddah and Makkah, respectively.

  18. In-situ suspended aggregate microextraction of gold nanoparticles from water samples and determination by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Choleva, Tatiana G; Kappi, Foteini A; Tsogas, George Z; Vlessidis, Athanasios G; Giokas, Dimosthenis L

    2016-05-01

    This work describes a new method for the extraction and determination of gold nanoparticles in environmental samples by means of in-situ suspended aggregate microextraction and electrothermal atomic absorption spectrometry. The method relies on the in-situ formation of a supramolecular aggregate phase through ion-association between a cationic surfactant and a benzene sulfonic acid derivative. Gold nanoparticles are physically entrapped into the aggregate phase which is separated from the bulk aqueous solution by vacuum filtration on the surface of a cellulose filter in the form of a thin film. The film is removed from the filter surface and is dissociated into an acidified methanolic solution which is used for analysis. Under the optimized experimental conditions, gold nanoparticles can be efficiently extracted from water samples with recovery rates between 81.0-93.3%, precision 5.4-12.0% and detection limits as low as 75femtomolL(-1) using only 20mL of sample volume. The satisfactory analytical features of the method along with the simplicity indicate the efficiency of this new approach to adequately collect and extract gold nanoparticle species from water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Exploring the Legionella pneumophila positivity rate in hotel water samples from Antalya, Turkey.

    Science.gov (United States)

    Sepin Özen, Nevgün; Tuğlu Ataman, Şenay; Emek, Mestan

    2017-05-01

    The genus Legionella is a fastidious Gram-negative bacteria widely distributed in natural waters and man made water supply systems. Legionella pneumophila is the aetiological agent of approximately 90% of reported Legionellosis cases, and serogroup 1 is the most frequent cause of infections. Legionnaires' disease is often associated with travel and continues to be a public health concern at present. The correct water management quality practices and rapid methods for analyzing Legionella species in environmental water is a key point for the prevention of Legionnaires' disease outbreaks. This study aimed to evaluate the positivity rates and serotyping of Legionella species from water samples in the region of Antalya, Turkey, which is an important tourism center. During January-December 2010, a total of 1403 samples of water that were collected from various hotels (n = 56) located in Antalya were investigated for Legionella pneumophila. All samples were screened for L. pneumophila by culture method according to "ISO 11731-2" criteria. The culture positive Legionella strains were serologically identified by latex agglutination test. A total of 142 Legionella pneumophila isolates were recovered from 21 (37.5%) of 56 hotels. The total frequency of L. pneumophila isolation from water samples was found as 10.1%. Serological typing of 142 Legionella isolates by latex agglutination test revealed that strains belonging to L. pneumophila serogroups 2-14 predominated in the examined samples (85%), while strains of L. pneumophila serogroup 1 were less numerous (15%). According to our knowledge, our study with the greatest number of water samples from Turkey demonstrates that L. pneumophila serogroups 2-14 is the most common isolate. Rapid isolation of L. pneumophila from environmental water samples is essential for the investigation of travel related outbreaks and the possible resources. Further studies are needed to have epidemiological data and to determine the types of L

  20. Journal of Sustainable Development of Energy, Water and Environment Systems - Volume II

    Directory of Open Access Journals (Sweden)

    Neven Duić

    2014-12-01

    Full Text Available The Journal of Sustainable Development of Energy, Water and Environment Systems – JSDEWES is an international journal dedicated to the improvement and dissemination of knowledge on methods, policies and technologies for increasing the sustainability of development by de-coupling growth from natural resources and replacing them with knowledge based economy, taking into account its economic, environmental and social pillars, as well as methods for assessing and measuring sustainability of development, regarding energy, transport, water, environment and food production systems and their many combinations. In total 32 manuscripts were published in Volume II, all of them reviewed by at least two reviewers. The Journal of Sustainable Development of Energy, Water and Environment Systems would like to thank reviewers for their contribution to the quality of the published manuscripts.

  1. Supplement to the UMTRA project water sampling and analysis plan, Slick Rock, Colorado

    International Nuclear Information System (INIS)

    1995-09-01

    The water sampling and analysis plan (WSAP) provides the regulatory and technical basis for ground water and surface water sampling at the Uranium Mill Tailings Remedial Action (UMTRA) Project Union Carbide (UC) and North Continent (NC) processing sites and the Burro Canyon disposal site near Slick Rock, Colorado. The initial WSAP was finalized in August 1994 and will be completely revised in accordance with the WSAP guidance document (DOE, 1995) in late 1996. This version supplements the initial WSAP, reflects only minor changes in sampling that occurred in 1995, covers sampling scheduled for early 1996, and provides a preliminary projection of the next 5 years of sampling and monitoring activities. Once surface remedial action is completed at the former processing sites, additional and more detailed hydrogeologic characterization may be needed to develop the Ground Water Program conceptual ground water model and proposed compliance strategy. In addition, background ground water quality needs to be clearly defined to ensure that the baseline risk assessment accurately estimated risks from the contaminants of potential concern in contaminated ground water at the UC and NC sites

  2. Microbiology of the surface water samples in the high background radiation areas of Ramsar, Iran

    International Nuclear Information System (INIS)

    Motamedifar, Mohammad; Zamani, Khosrow; Sedigh, Hadi; Mortazavi, Seyed Mohammad Javad; Taeb, Shahram; Haghani, M.; Mortazavi, Seyed Ali Reza; Soofi, Amir

    2014-01-01

    Residents of high background radiation areas of Ramsar have lived in these areas for many generations and received radiation doses much higher than the dose limit recommended by ICRP for radiation workers. The radioactivity of the high background radiation areas of Ramsar is reported to be due to 226 Ra and its decay products, which have been brought to the surface by the waters of hot springs. Over the past years the department has focused on different aspects of the health effects of the elevated levels of natural radiation in Ramsar. This study was aimed to perform a preliminary investigation on the bioeffects of exposure to elevated levels of natural radiation on the microbiology of surface water samples. Water samples were collected from surface water streams in Talesh Mahalleh district, Ramsar as well as a nearby area with normal levels of background radiation. Only two strains of bacteria, that is, Providencia stuartii and Shimwellia blattae, could be isolated from the water samples collected from high background radiation areas, while seven strains (Escherichia coli, Enterobacter asburiae, Klebsiella pneumoniae, Shigella dysenteriae, Buttiauxella agerstis, Tatumella punctuata and Raoultella ornithinolytica) were isolated from the water samples collected from normal background radiation areas. All the bacteria isolated from water samples of high and normal background radiation areas were sensitive to ultraviolet radiation, heat, betadine, alcohol, and deconex. Although other investigators have reported that bacteria isolated from hot springs show radioresistance, the results reported here do not reveal any adaptive response. (author)

  3. Review of robust measurement of phosphorus in river water: sampling, storage, fractionation and sensitivity

    Directory of Open Access Journals (Sweden)

    H. P. Jarvie

    2002-01-01

    Full Text Available This paper reviews current knowledge on sampling, storage and analysis of phosphorus (P in river waters. Potential sensitivity of rivers with different physical, chemical and biological characteristics (trophic status, turbidity, flow regime, matrix chemistry is examined in terms of errors associated with sampling, sample preparation, storage, contamination, interference and analytical errors. Key issues identified include: The need to tailor analytical reagents and concentrations to take into account the characteristics of the sample matrix. The effects of matrix interference on the colorimetric analysis. The influence of variable rates of phospho-molybdenum blue colour formation. The differing responses of river waters to physical and chemical conditions of storage. The higher sensitivities of samples with low P concentrations to storage and analytical errors. Given high variability of river water characteristics in space and time, no single standardised methodology for sampling, storage and analysis of P in rivers can be offered. ‘Good Practice’ guidelines are suggested, which recommend that protocols for sampling, storage and analysis of river water for P is based on thorough site-specific method testing and assessment of P stability on storage. For wider sampling programmes at the regional/national scale where intensive site-specific method and stability testing are not feasible, ‘Precautionary Practice’ guidelines are suggested. The study highlights key areas requiring further investigation for improving methodological rigour. Keywords: phosphorus, orthophosphate, soluble reactive, particulate, colorimetry, stability, sensitivity, analytical error, storage, sampling, filtration, preservative, fractionation, digestion

  4. Guidance document for preparing water sampling and analysis plans for UMTRA Project sites. Revision 1

    International Nuclear Information System (INIS)

    1995-09-01

    A water sampling and analysis plan (WSAP) is prepared for each Uranium Mill Tailings Remedial Action (UMTRA) Project site to provide the rationale for routine ground water sampling at disposal sites and former processing sites. The WSAP identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the routine ground water monitoring stations at each site. This guidance document has been prepared by the Technical Assistance Contractor (TAC) for the US Department of Energy (DOE). Its purpose is to provide a consistent technical approach for sampling and monitoring activities performed under the WSAP and to provide a consistent format for the WSAP documents. It is designed for use by the TAC in preparing WSAPs and by the DOE, US Nuclear Regulatory Commission, state and tribal agencies, other regulatory agencies, and the public in evaluating the content of WSAPS

  5. Soil and Water – What is Detectable through Microbiological Sample Preparation Techniques

    Science.gov (United States)

    The concerns of a potential terrorist’s use of biological agents in soil and ground water are articulated by comparisons to major illnesses in this Country involving contaminated drinking water sources. Objectives are focused on the importance of sample preparation in the rapid, ...

  6. Analysis of trace uranium and plutonium in environmental water sample by ICP-MS

    International Nuclear Information System (INIS)

    Liu Xuemei

    2004-12-01

    The analysis of trace Uranium and Plutonium in environmental water is very important in the environment inspect. The preparation method of water samples are introduced and several common used method are compared. The analysis process and the calibration method with ICP-MS are discussed in detail considering present conditions. (author)

  7. Natural radioactivity in various water samples and radiation dose estimations in Bolu province, Turkey.

    Science.gov (United States)

    Gorur, F Korkmaz; Camgoz, H

    2014-10-01

    The level of natural radioactivity for Bolu province of north-western Turkey was assessed in this study. There is no information about radioactivity measurement reported in water samples in the Bolu province so far. For this reason, gross α and β activities of 55 different water samples collected from tap, spring, mineral, river and lake waters in Bolu were determined. The mean activity concentrations were 68.11 mBq L(-1), 169.44 mBq L(-1) for gross α and β in tap water. For all samples the gross β activity is always higher than the gross α activity. All value of the gross α were lower than the limit value of 500 mBq L(-1) while two spring and one mineral water samples were found to have gross β activity concentrations of greater than 1000 mBq L(-1). The associated age-dependent dose from all water ingestion in Bolu was estimated. The total dose for adults had an average value exceeds the WHO recommended limit value. The risk levels from the direct ingestion of the natural radionuclides in tap and mineral water in Bolu were determinated. The mean (210)Po and (228)Ra risk the value of tap and mineral waters slightly exceeds what some consider on acceptable risk of 10(-4) or less. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Stable isotope ratio measurements on highly enriched water samples by means of laser spectrometry

    NARCIS (Netherlands)

    van Trigt, R; Kerstel, E.R.T.; Visser, GH; Meijer, H.A.J.

    2001-01-01

    We demonstrate the feasibility of using laser spectrometry (LS) to analyze isotopically highly enriched water samples (i.e., delta H-2 less than or equal to 15000 parts per thousand, delta O-18 less than or equal to 1200 parts per thousand), as often used in the biomedical doubly labeled water (DLW)

  9. Quality control on the accuracy of the total Beta activity index in different sample matrices water

    International Nuclear Information System (INIS)

    Pujol, L.; Pablo, M. A. de; Payeras, J.

    2013-01-01

    The standard ISO/IEC 17025:2005 of general requirements for the technical competence of testing and calibration laboratories, provides that a laboratory shall have quality control procedures for monitoring the validity of tests and calibrations ago. In this paper, the experience of Isotopic Applications Laboratory (CEDEX) in controlling the accuracy rate of total beta activity in samples of drinking water, inland waters and marine waters is presented. (Author)

  10. Introduction of Flame Atomic Absorption Spectrometry (FAAS) For River Water Samples Analysis

    International Nuclear Information System (INIS)

    Shakirah Abd Shukor; Mohd Suhaimi Hamzah; Shamsiah Abdul Rahman

    2015-01-01

    Metal contamination in water is a major component in the determination of water quality monitoring. In spite of the viability of several other metal ion analysis techniques for river water, atomic absorption spectroscopy (AAS) method is most commonly used due to the reproducibility results, short analysis time, cost effective, lower level detection and robust. Therefore, this article gives an overview on the principles, instrumentation techniques, sample preparations, instrument calibration and data analysis in a simple manner for beginner. (author)

  11. Mechanisms controlling the volume of pleural fluid and extravascular lung water

    Directory of Open Access Journals (Sweden)

    G. Miserocchi

    2009-12-01

    Full Text Available Pleural and interstitial lung fluid volumes are strictly controlled and maintained at the minimum thanks to the ability of lymphatics to match the increase in filtration rate. In the pleural cavity, fluid accumulation is easily accommodated by retraction of lung and chest wall (high compliance of the pleural space; the increase of lymph flow per unit increase in pleural fluid volume is high due to the great extension of the parietal lymphatic. However, for the lung interstitium, the increase in lymph flow to match increased filtration does not need to be so great. In fact, increased filtration only causes a minor increase in extravascular water volume (<10% due to a marked increase in interstitial pulmonary pressure (low compliance of the extracellular matrix which, in turn, buffers further filtration. Accordingly, a less extended lymphatic network is needed. The efficiency of lymphatic control is achieved through a high lymphatic conductance in the pleural fluid and through a low interstitial compliance for the lung interstitium. Fluid volume in both compartments is so strictly controlled that it is difficult to detect initial deviations from the physiological state; thus, a great physiological advantage turns to be a disadvantage on a clinical basis as it prevents an early diagnosis of developing disease.

  12. Hexagonal boron nitride nanosheets as adsorbents for solid-phase extraction of polychlorinated biphenyls from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Shiliang; Wang, Zhenhua; Ding, Ning [Key Laboratory for Applied Technology of Sophisticated Analytical Instruments, Shandong Academy of Sciences, Jinan, Shandong (China); Elaine Wong, Y.-L. [Department of Chemistry, The Chinese University of Hong Kong, Hong Kong Special Administrative Region (Hong Kong); Chen, Xiangfeng, E-mail: xiangfchensdas@163.com [Key Laboratory for Applied Technology of Sophisticated Analytical Instruments, Shandong Academy of Sciences, Jinan, Shandong (China); Department of Chemistry, The Chinese University of Hong Kong, Hong Kong Special Administrative Region (Hong Kong); Qiu, Guangyu [Department of Physics and Materials Science, City University of Hong Kong, Hong Kong Special Administrative Region (Hong Kong); Dominic Chan, T.-W., E-mail: twdchan@cuhk.edu.hk [Department of Chemistry, The Chinese University of Hong Kong, Hong Kong Special Administrative Region (Hong Kong)

    2016-09-14

    The adsorptive potential of hexagonal boron nitride nanosheets (h-BNNSs) for solid-phase extraction (SPE) of pollutants was investigated for the first time. Seven indicators of polychlorinated biphenyls (PCBs) were selected as target analytes. The adsorption of PCBs on the surface of the h-BNNSs in water was simulated by the density functional theory and molecular dynamics. The simulation results indicated that the PCBs are adsorbed on the surface by π–π, hydrophobic, and electrostatic interactions. The PCBs were extracted with an h-BNNS-packed SPE cartridge, and eluted by dichloromethane. Gas chromatography–tandem mass spectrometry working in the multiple reaction monitor mode was used for the sample quantification. The effect of extraction parameters, including the flow rate, pH value, breakthrough volume, and the ionic strength, were investigated. Under the optimal working conditions, the developed method showed low limits of detection (0.24–0.50 ng L{sup −1}; signal-to-noise ratio = 3:1), low limits of quantification (0.79–1.56 ng L{sup −1}; signal-to-noise ratio = 10:1), satisfactory linearity (r > 0.99) within the concentration range of 2–1000 ng L{sup −1}, and good precision (relative standard deviation < 12%). The PCBs concentration in environmental water samples was determined by the developed method. This results demonstrate that h-BNNSs have high analytical potential in the enrichment of pollutants. - Highlights: • The hexagonal boron nitride nanosheets were synthesized. • The nanosheets were used as adsorbent for solid-phase extraction. • The h-BN demonstrates remarkable adsorption of PCBs from water samples. • The method was successfully applied in determination of PCBs in water samples.

  13. Automatic sampling technology in wide belt conveyor with big volume of coal flow

    Energy Technology Data Exchange (ETDEWEB)

    Liu, J. [China Coal Research Institute, Beijing (China)

    2008-06-15

    The principle and technique of sampling in a wide belt conveyor with high coal flow was studied. The design method of the technology, the key parameters, the collection efficiency, the mechanical unit, power supply and control system and worksite facility were ascertained. 3 refs., 5 figs.

  14. Casingless down-hole for sealing an ablation volume and obtaining a sample for analysis

    Science.gov (United States)

    Noble, Donald T.; Braymen, Steven D.; Anderson, Marvin S.

    1996-10-01

    A casing-less down hole sampling system for acquiring a subsurface sample for analysis using an inductively coupled plasma system is disclosed. The system includes a probe which is pushed into the formation to be analyzed using a hydraulic ram system. The probe includes a detachable tip member which has a soil point mad a barb, with the soil point aiding the penetration of the earth, and the barb causing the tip member to disengage from the probe and remain in the formation when the probe is pulled up. The probe is forced into the formation to be tested, and then pulled up slightly, to disengage the tip member and expose a column of the subsurface formation to be tested. An instrumentation tube mounted in the probe is then extended outward from the probe to longitudinally extend into the exposed column. A balloon seal mounted on the end of the instrumentation tube allows the bottom of the column to be sealed. A source of laser radiation is emitted from the instrumentation tube to ablate a sample from the exposed column. The instrumentation tube can be rotated in the probe to sweep the laser source across the surface of the exposed column. An aerosol transport system carries the ablated sample from the probe to the surface for testing in an inductively coupled plasma system. By testing at various levels in the down-hole as the probe is extracted from the soil, a profile of the subsurface formation may be obtained.

  15. Qualilty, isotopes, and radiochemistry of water sampled from the Upper Moenkopi Village water-supply wells, Coconino County, Arizona

    Science.gov (United States)

    Carruth, Rob; Beisner, Kimberly; Smith, Greg

    2013-01-01

    The Hopi Tribe Water Resources Program has granted contracts for studies to evaluate water supply conditions for the Moenkopi villages in Coconino County, Arizona. The Moenkopi villages include Upper Moenkopi Village and the village of Lower Moencopi, both on the Hopi Indian Reservation south of the Navajo community of Tuba City. These investigations have determined that water supplies are limited and vulnerable to several potential sources of contamination, including the Tuba City Landfill and a former uranium processing facility known as the Rare Metals Mill. Studies are ongoing to determine if uranium and other metals in groundwater beneath the landfill are greater than regional groundwater concentrations. The source of water supply for the Upper Moenkopi Village is three public-supply wells. The wells are referred to as MSW-1, MSW-2, and MSW-3 and all three wells obtain water from the regionally extensive N aquifer. The N aquifer is the principal aquifer in this region of northern Arizona and consists of thick beds of sandstone between less permeable layers of siltstone and mudstone. The relatively fine-grained character of the N aquifer inhibits rapid movement of water and large yields to wells. In recent years, water levels have declined in the three public-supply wells, causing concern that the current water supply will not be able to accommodate peak demand and allow for residential and economic growth. Analyses of major ions, nutrients, selected trace metals, stable and radioactive isotopes, and radiochemistry were performed on the groundwater samples from the three public-supply wells to describe general water-quality conditions and groundwater ages in and immediately surrounding the Upper Moenkopi Village area. None of the water samples collected from the public-supply wells exceeded the U.S. Environmental Protection Agency primary drinking water standards. The ratios of the major dissolved ions from the samples collected from MSW-1 and MSW-2 indicate

  16. Absolute measurement of the isotopic ratio of a water sample with very low deuterium content

    International Nuclear Information System (INIS)

    Hagemann, R.; Nief, G.; Roth, E.

    1968-01-01

    The presence of H 3+ ions which are indistinguishable from HD + ions presents the principal difficulty encountered in the measurement of isotopic ratios of water samples with very low deuterium contents using a mass spectrometer. Thus, when the sample contains no deuterium, the mass spectrometer does not indicate zero. By producing, in situ, from the sample to be measured, water vapor with an isotopic ratio very close to zero using a small distilling column, this difficulty is overcome. This column, its operating parameters, as well as the way in which the measurements are made are described. An arrangement is employed in which the isotopic ratios can be measured with a sensitivity better than 0.01 x 10 -6 . The method is applied to the determination of the isotopic ratios of three low deuterium content water samples. The results obtained permit one to assign to the sample with the lowest deuterium content an absolute value equal to 1.71 ± 0.03 ppm. This water sample is a primary standard from which is determined the isotopic ratio of a natural water sample which serves as the laboratory standard. (author) [fr

  17. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  18. Physicochemical transformation and algal toxicity of engineered nanoparticles in surface water samples

    International Nuclear Information System (INIS)

    Zhang, Luqing; Li, Jingyi; Yang, Kun; Liu, Jingfu; Lin, Daohui

    2016-01-01

    Most studies on the behavior and toxicity of engineered nanoparticles (NPs) have been conducted in artificial water with well-controlled conditions, which are dramatically different from natural waters with complex compositions. To better understand the fate and toxicity of NPs in the natural water environment, physicochemical transformations of four NPs (TiO_2, ZnO, Ag, and carbon nanotubes (CNTs)) and their toxicities towards a unicellular green alga (Chlorella pyrenoidosa) in four fresh water and one seawater sample were investigated. Results indicated that water chemistry had profound effects on aggregation, dissolution, and algal toxicity of the NPs. The strongest homoaggregation of the NPs was associated with the highest ionic strength, but no obvious correlation was observed between the homoaggregation of NPs and pH or dissolved organic matter content of the water samples. The greatest dissolution of ZnO NPs also occurred in seawater with the highest ionic strength, while the dissolution of Ag NPs varied differently from ZnO NPs. The released Zn"2"+ and especially Ag"+ mainly accounted for the algal toxicity of ZnO and Ag NPs, respectively. The NP-cell heteroagglomeration occurred generally for CNTs and Ag NPs, which contributed to the observed nanotoxicity. However, there was no significant correlation between the observed nanotoxicity and the type of NP or the water chemistry. It was thus concluded that the physicochemical transformations and algal toxicities of NPs in the natural water samples were caused by the combined effects of complex water quality parameters rather than any single influencing factor alone. These results will increase our knowledge on the fate and effects of NPs in the aquatic environment. - Highlights: • Transformation and algal toxicity of four NPs in five surface water samples were studied. • The transformation and toxicity were dependent on the types of NPs and water samples. • No single water parameter alone was

  19. Extension of a dynamic headspace multi-volatile method to milliliter injection volumes with full sample evaporation: Application to green tea.

    Science.gov (United States)

    Ochiai, Nobuo; Sasamoto, Kikuo; Tsunokawa, Jun; Hoffmann, Andreas; Okanoya, Kazunori; MacNamara, Kevin

    2015-11-20

    An extension of multi-volatile method (MVM) technology using the combination of a standard dynamic headspace (DHS) configuration, and a modified DHS configuration incorporating an additional vacuum module, was developed for milliliter injection volume of aqueous sample with full sample evaporation. A prior step involved investigation of water management by weighing of the water residue in the adsorbent trap. The extended MVM for 1 mL aqueous sample consists of five different DHS method parameter sets including choice of the replaceable adsorbent trap. An initial two DHS sampling sets at 25°C with the standard DHS configuration using a carbon-based adsorbent trap target very volatile solutes with high vapor pressure (>10 kPa) and volatile solutes with moderate vapor pressure (1-10 kPa). Subsequent three DHS sampling sets at 80°C with the modified DHS configuration using a Tenax TA trap target solutes with low vapor pressure (88%) for 17 test aroma compounds and moderate recoveries (44-71%) for 4 test compounds. The method showed good linearity (r(2)>0.9913) and high sensitivity (limit of detection: 0.1-0.5 ng mL(-1)) even with MS scan mode. The improved sensitivity of the method was demonstrated with analysis of a wide variety of aroma compounds in brewed green tea. Compared to the original 100 μL MVM procedure, this extension to 1 mL MVM allowed detection of nearly twice the number of aroma compounds, including 18 potent aroma compounds from top-note to base-note (e.g. 2,3-butanedione, coumarin, furaneol, guaiacol, cis-3-hexenol, linalool, maltol, methional, 3-methyl butanal, 2,3,5-trimethyl pyrazine, and vanillin). Sensitivity for 23 compounds improved by a factor of 3.4-15 under 1 mL MVM conditions. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Evaluation of sampling inhalable PM10 particulate matter (≤ 10 μm) using co-located high volume samplers

    International Nuclear Information System (INIS)

    Rajoy, R R S; Dias, J W C; Rego, E C P; Netto, A D Pereira

    2015-01-01

    This paper presents the results of the determination of the concentrations of atmospheric particulate matter ≤ 10 μm (PM10), collected simultaneously by six PM10 high volume samplers from two different manufacturers installed in the same location. Fifteen samples of 24 h were obtained with each equipment at a selected urban area of Rio de Janeiro city. The concentration of PM10 ranged between 10.73 and 54.04 μg m −3 . The samplers were considered comparable to each other, as the adopted methodology presented good repeatability

  1. Development of flow injection method for indirect copper determination with amperometric detection in drinking water samples

    Directory of Open Access Journals (Sweden)

    Nikolić-Mandić Snežana

    2012-01-01

    Full Text Available A gas-diffusion flow injection method with amperometric detection for indirect copper determination on a silver electrode is developed. The flow through system is equipped with two injection valves and a gas-diffusion unit. In the first step, a signal of cyanide solution was recorded. In the following step a signal of cyanide in the presence of copper was measured. Interferences (Cd(II, Co(II, Ag(I, Ni(II, Fe(III, Hg(II and Zn(II were investigated and successfully removed. The calibration graph is linear in the range 1-90 μmol dm-3 of copper, correlation coefficient is 0.993, the regression equation is I = (0.0455±0.0015c + (0.4611±0.0671, I is relative signal decrease in μA and c is concentration in μmol dm-3. Relative standard deviation for six consecutive injections of 30 μmol dm-3 copper(II was 1.47 % and for 1 μmol dm-3 copper(II was 3.40 %. The detection limit, calculated as 3 s/m (where s is a standard deviation of nine measurement of a reagent blank and m is the slope of the calibration curve, was 0.32 μmol dm-3, which corresponds to 2.44 ng of copper(II (loop volume was 0.12 cm3. The method enables 60 analyses per hour and it was successfully applied on determination of copper in drinking water samples. [Acknowledgements. The authors acknowledge the grant from the Ministry of Education and Science of the Republic of Serbia, Project number 172051

  2. Evaluation of the Validity of Groundwater Samples Obtained Using the Purge Water Management System at SRS

    International Nuclear Information System (INIS)

    Beardsley, C.C.

    1999-01-01

    As part of the demonstration testing of the Purge Water Management System (PWMS) technology at the Savannah River Site (SRS), four wells were equipped with PWMS units in 1997 and a series of sampling events were conducted at each during 1997-1998. Three of the wells were located in A/M Area while the fourth was located at the Old Radioactive Waste Burial Ground in the General Separations Area.The PWMS is a ''closed-loop'', non-contact, system used to collect and return purge water to the originating aquifer after a sampling event without having significantly altered the water quality. One of the primary concerns as to its applicability at SRS, and elsewhere, is whether the PWMS might resample groundwater that is returned to the aquifer during the previous sampling event. The purpose of the present investigation was to compare groundwater chemical analysis data collected at the four test wells using the PWMS vs. historical data collected using the standard monitoring program methodology to determine if the PWMS provides representative monitoring samples.The analysis of the groundwater chemical concentrations indicates that the PWMS sampling methodology acquired representative groundwater samples at monitoring wells ABP-1A, ABP-4, ARP-3 and BGO-33C. Representative groundwater samples are achieved if the PWMS does not resample groundwater that has been purged and returned during a previous sampling event. Initial screening calculations, conducted prior to the selection of these four wells, indicated that groundwater velocities were high enough under the ambient hydraulic gradients to preclude resampling from occurring at the time intervals that were used at each well. Corroborating evidence included a tracer test that was conducted at BGO-33C, the high degree of similarity between analyte concentrations derived from the PWMS samples and those obtained from historical protocol sampling, as well as the fact that PWMS data extend all previously existing concentration

  3. Determination of natural uranium, thorium and radium isotopes in water and soil samples by alpha spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Le Cong; Tao, Chau Van; Thong, Luong Van; Linh, Duong Mong [University of Science Ho Chi Minh City (Viet Nam). Faculty of Physics and Engineering Physics; Dong, Nguyen Van [University of Science Ho Chi Minh City (Viet Nam). Faculty of Chemistry

    2011-08-15

    In this study, a simple procedure for the determination of natural uranium, thorium and radium isotopes in water and soil samples by alpha spectroscopy is described. This procedure allows a sequential extraction polonium, uranium, thorium and radium radionuclides from the same sample in two to three days. It was tested and validated with the analysis of certified reference materials from the IAEA. (orig.)

  4. Use of passive sampling devices for monitoring and compliance checking of POP concentrations in water

    NARCIS (Netherlands)

    Lohmann, R.; Booij, K.; Smedes, F.; Vrana, B.

    2012-01-01

    The state of the art of passive water sampling of (nonpolar) organic contaminants is presented. Its suitability for regulatory monitoring is discussed, with an emphasis on the information yielded by passive sampling devices (PSDs), their relevance and associated uncertainties. Almost all persistent

  5. Study of the concentration of 7 Be in samples of rain water

    International Nuclear Information System (INIS)

    Quintero P, E.; Rojas M, V.P.

    2004-01-01

    This work shows the methodology carried out for the determination of 7 Be in samples of rain water and the obtained results of the concentration of having said radionuclide in this sampled matrix during the last five years in the Nuclear Center of Mexico. (Author)

  6. Study of changes in bacterial and viral abundance in formaldehyde - Fixed water samples by epifluorescence microscopy

    Digital Repository Service at National Institute of Oceanography (India)

    Parvathi, A.; Radhakrishnan, S.; Sajila, M.P.; Jacob, B.

    of bacteria and viruses in water samples from Cochin Backwater was determined by SYBR Green I staining and epifluorescence microscopy. The counts were determined for 45 days in samples fixed with 1–6% formaldehyde. The results suggest rapid decline in counts...

  7. PASSIVE SAMPLING OF GROUND WATER MONITORING WELLS WITHOUT PURGING MULTILEVEL WELL CHEMISTRY AND TRACER DISAPPEARANCE

    Science.gov (United States)

    It is essential that the sampling techniques utilized in groundwater monitoring provide data that accurately depicts the water quality of the sampled aquifer in the vicinity of the well. Due to the large amount of monitoring activity currently underway in the U.S.A. it is also im...

  8. Concentration of ions in selected bottled water samples sold in Malaysia

    Science.gov (United States)

    Aris, Ahmad Zaharin; Kam, Ryan Chuan Yang; Lim, Ai Phing; Praveena, Sarva Mangala

    2013-03-01

    Many consumers around the world, including Malaysians, have turned to bottled water as their main source of drinking water. The aim of this study is to determine the physical and chemical properties of bottled water samples sold in Selangor, Malaysia. A total of 20 bottled water brands consisting of `natural mineral (NM)' and `packaged drinking (PD)' types were randomly collected and analyzed for their physical-chemical characteristics: hydrogen ion concentration (pH), electrical conductivity (EC) and total dissolved solids (TDS), selected major ions: calcium (Ca), potassium (K), magnesium (Mg) and sodium (Na), and minor trace constituents: copper (Cu) and zinc (Zn) to ascertain their suitability for human consumption. The results obtained were compared with guideline values recommended by World Health Organization (WHO) and Malaysian Ministry of Health (MMOH), respectively. It was found that all bottled water samples were in accordance with the guidelines set by WHO and MMOH except for one sample (D3) which was below the pH limit of 6.5. Both NM and PD bottled water were dominated by Na + K > Ca > Mg. Low values for EC and TDS in the bottled water samples showed that water was deficient in essential elements, likely an indication that these were removed by water treatment. Minerals like major ions were present in very low concentrations which could pose a risk to individuals who consume this water on a regular basis. Generally, the overall quality of the supplied bottled water was in accordance to standards and guidelines set by WHO and MMOH and safe for consumption.

  9. Real-time viscosity and mass density sensors requiring microliter sample volume based on nanomechanical resonators.

    Science.gov (United States)

    Bircher, Benjamin A; Duempelmann, Luc; Renggli, Kasper; Lang, Hans Peter; Gerber, Christoph; Bruns, Nico; Braun, Thomas

    2013-09-17

    A microcantilever based method for fluid viscosity and mass density measurements with high temporal resolution and microliter sample consumption is presented. Nanomechanical cantilever vibration is driven by photothermal excitation and detected by an optical beam deflection system using two laser beams of different wavelengths. The theoretical framework relating cantilever response to the viscosity and mass density of the surrounding fluid was extended to consider higher flexural modes vibrating at high Reynolds numbers. The performance of the developed sensor and extended theory was validated over a viscosity range of 1-20 mPa·s and a corresponding mass density range of 998-1176 kg/m(3) using reference fluids. Separating sample plugs from the carrier fluid by a two-phase configuration in combination with a microfluidic flow cell, allowed samples of 5 μL to be sequentially measured under continuous flow, opening the method to fast and reliable screening applications. To demonstrate the study of dynamic processes, the viscosity and mass density changes occurring during the free radical polymerization of acrylamide were monitored and compared to published data. Shear-thinning was observed in the viscosity data at higher flexural modes, which vibrate at elevated frequencies. Rheokinetic models allowed the monomer-to-polymer conversion to be tracked in spite of the shear-thinning behavior, and could be applied to study the kinetics of unknown processes.

  10. DETERMINATION OF ORGANOCHLORINE PESTICIDES IN DRINKING WATERS SAMPLED FROM CLUJ AND HUNEDOARA COUNTIES

    Directory of Open Access Journals (Sweden)

    MARIA-ELISABETA LOVÁSZ

    2011-03-01

    Full Text Available Determination of organochlorine pesticides in drinking waterssampled from Cluj and Hunedoara counties. Pesticides are found scattered indifferent environmental factors (water, air, soil wherefrom they are drawn off byvegetal and animal organisms. Water pollution by pesticides results from the plantprotection products industry and also from massive application of these resourcesin agriculture and other branches of economy. Pesticides can reach surface wateralong with dripping waters and by infiltration may reach the groundwater layers,organochlorine pesticides are most often found in the water sources (dieldrin,endrin, DDT, aldrin, lindane, heptachlor, etc. due to their increased persistence inthe external environment. This study followed up the determination oforganochlorine pesticides in 14 drinking water samples collected from the outputof water treatment plants in Cluj and Hunedoara counties that process surfacewater and deep-water sources. For identification of organochlorine pesticides, thegas chromatographic method after liquid-liquid extraction was used, by a gascromatograph Shimadzu GC 2010 with detector ECD (Electron CaptureDetection. There were not detected higher values than the method detection limit(0.01 μg/l in the drinking water samples collected and analyzed for both totalorganochlorine pesticides and components, which were well below the maximumconcentration admitted by Law 452/2002 regarding drinking water quality. Resultsare correlated with the sanitary protection areas for water sources and with the useof agricultural lands in the area. The solution to reduce risk of pesticides use isecological agriculture , which gains increasingly more ground in Romania too.

  11. Optimization of the Water Volume in the Buckets of Pico Hydro Overshot Waterwheel by Analytical Method

    Science.gov (United States)

    Budiarso; Adanta, Dendy; Warjito; Siswantara, A. I.; Saputra, Pradhana; Dianofitra, Reza

    2018-03-01

    Rapid economic and population growth in Indonesia lead to increased energy consumption, including electricity needs. Pico hydro is considered as the right solution because the cost of investment and operational cost are fairly low. Additionally, Indonesia has many remote areas with high hydro-energy potential. The overshot waterwheel is one of technology that is suitable to be applied in remote areas due to ease of operation and maintenance. This study attempts to optimize bucket dimensions with the available conditions. In addition, the optimization also has a good impact on the amount of generated power because all available energy is utilized maximally. Analytical method is used to evaluate the volume of water contained in bucket overshot waterwheel. In general, there are two stages performed. First, calculation of the volume of water contained in each active bucket is done. If the amount total of water contained is less than the available discharge in active bucket, recalculation at the width of the wheel is done. Second, calculation of the torque of each active bucket is done to determine the power output. As the result, the mechanical power generated from the waterwheel is 305 Watts with the efficiency value of 28%.

  12. Nuclear piping criteria for Advanced Light-Water Reactors, Volume 1--Failure mechanisms and corrective actions

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This WRC Bulletin concentrates on the major failure mechanisms observed in nuclear power plant piping during the past three decades and on corrective actions taken to minimize or eliminate such failures. These corrective actions are applicable to both replacement piping and the next generation of light-water reactors. This WRC Bulletin was written with the objective of meeting a need for piping criteria in Advanced Light-Water Reactors, but there is application well beyond the LWR industry. This Volume, in particular, is equally applicable to current nuclear power plants, fossil-fueled power plants, and chemical plants including petrochemical. Implementation of the recommendations for mitigation of specific problems should minimize severe failures or cracking and provide substantial economic benefit. This volume uses a case history approach to high-light various failure mechanisms and the corrective actions used to resolve such failures. Particular attention is given to those mechanisms leading to severe piping failures, where severe denotes complete severance, large ''fishmouth'' failures, or long throughwall cracks releasing a minimum of 50 gpm. The major failure mechanisms causing severe failure are erosion-corrosion and vibrational fatigue. Stress corrosion cracking also has been a common problem in nuclear piping systems. In addition thermal fatigue due to mixing-tee and to thermal stratification also is discussed as is microbiologically-induced corrosion. Finally, water hammer, which represents the ultimate in internally-generated dynamic high-energy loads, is discussed

  13. May 2011 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

    International Nuclear Information System (INIS)

    2011-01-01

    Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 16-17, 2011, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location Johnson Artesian WL. Samples were analyzed by the U.S. Environmental Protection Agency (EPA) Radiation&Indoor Environments National Laboratory in Las Vegas, Nevada. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry, and for tritium using the conventional method. Tritium was not measured using the enrichment method because the EPA laboratory no longer offers that service. Results of this monitoring at the Rio Blanco site demonstrate that groundwater and surface water outside the boundaries have not been affected by project-related contaminants.

  14. Inseminating dose and water volume applied to the artificial fertilization of Steindachneridion parahybae (Steindachner, 1877 (Siluriformes: Pimelodidae: Brazilian endangered fish

    Directory of Open Access Journals (Sweden)

    Eduardo Antônio Sanches

    Full Text Available Abstract The Steindachneridion parahybae is an endangered catfish from Brazil and strategies applied for gametes optimization are necessary. The aim of this study was to assess inseminating doses and water volume upon the fertilization, hatching rates and percentage of normal larvae in S. parahybae . Was used a randomized design in factorial scheme (4×4 with four inseminating doses: 1.0×104, 1.0×105, 1.0×106, 1.0×107spermatozoa oocyte-1 and four volumes of water: 1, 35, 65 and 95mL of water g-1 of oocytes. The combination of doses and volumes were performed in triplicates (n=48. Each incubator (1.5L of useful volume with 1g of oocytes was considered as an experimental unit. Significant interaction between inseminating doses and volumes of water to the values of the fertilization rates and quadratic effect of doses and volume for the values of hatching rates were observed. The doses and volumes did not influence the percentage of normal larvae (87.70±5.06%. It is recommended the use of 5.5×106 spermatozoa oocyte-1 and 1mL of water g-1 of oocytes during in vitro fertilization procedure. These results allowed us to develop new biotechnological strategies applied to the conservation of S. parahybae .

  15. Performance of a hydrostatic sampler for collecting samples at the water-sediment interface in lakes

    Directory of Open Access Journals (Sweden)

    Fernando PEDROZO

    2008-02-01

    Full Text Available The water-sediment interface plays a significant role in the determination of the trophic degree of a waterbody. Numerous redox reactions take place there, resulting in the release of contaminants from the sediments to the water column. The aim of the present work was to develop an equipment for collecting samples from the water-sediment interface. Such equipment was to have a simple design, low construction cost, no depth limitations, and high levels of personal safety and to be reliable in the collection of samples. The performance of the hydrostatic sampler thus developed was tested against samples collected either remotely with a corer or directly with syringes by autonomous divers. The hydrostatic sampler permits access to depths where the costs of the traditional diving methodology are expensive, and where working conditions are dangerous for the diver. The hydrostatic sampler provides an additional means of collecting samples from the water-sediment interface, which together with pore-water samples, facilitates the investigation and understanding of chemical mechanisms in lakes, for instance, those that control the P release from sediment to the water column.

  16. [Detecting Thallium in Water Samples using Dispersive Liquid Phase Microextraction-Graphite Furnace Atomic Absorption Spectroscopy].

    Science.gov (United States)

    Zhu, Jing; Li, Yan; Zheng, Bo; Tang, Wei; Chen, Xiao; Zou, Xiao-li

    2015-11-01

    To develope a method of solvent demulsification dispersive liquid phase microextraction (SD-DLPME) based on ion association reaction coupled with graphite furnace atomic absorption spectroscopy (GFAAS) for detecting thallium in water samples. Methods Thallium ion in water samples was oxidized to Tl(III) with bromine water, which reacted with Cl- to form TlCl4-. The ionic associated compound with trioctylamine was obtained and extracted. DLPME was completed with ethanol as dispersive solvent. The separation of aqueous and organic phase was achieved by injecting into demulsification solvent without centrifugation. The extractant was collected and injected into GFAAS for analysis. With palladium colloid as matrix modifier, a two step drying and ashing temperature programming process was applied for high precision and sensitivity. The linear range was 0.05-2.0 microg/L, with a detection limit of 0.011 microg/L. The relative standard derivation (RSD) for detecting Tl in spiked water sample was 9.9%. The spiked recoveries of water samples ranged from 94.0% to 103.0%. The method is simple, sensitive and suitable for batch analysis of Tl in water samples.

  17. White HDPE bottles as source of serious contamination of water samples with Ba and Zn.

    Science.gov (United States)

    Reimann, Clemens; Grimstvedt, Andreas; Frengstad, Bjørn; Finne, Tor Erik

    2007-03-15

    During a recent study of surface water quality factory new white high-density polyethylene (HDPE) bottles were used for collecting the water samples. According to the established field protocol of the Geological Survey of Norway the bottles were twice carefully rinsed with water in the field prior to sampling. Several blank samples using milli-Q (ELGA) water (>18.2 MOmega) were also prepared. On checking the analytical results the blanks returned values of Ag, Ba, Sr, V, Zn and Zr. For Ba and Zn the values (c. 300 microg/l and 95 microg/l) were about 10 times above the concentrations that can be expected in natural waters. A laboratory test of the bottles demonstrated that the bottles contaminate the samples with significant amounts of Ba and Zn and some Sr. Simple acid washing of the bottles prior to use did not solve the contamination problem for Ba and Zn. The results suggest that there may exist "clean" and "dirty" HDPE bottles depending on manufacturer/production process. When collecting water samples it is mandatory to check bottles regularly as a possible source of contamination.

  18. Effects of sterilization treatments on the analysis of TOC in water samples.

    Science.gov (United States)

    Shi, Yiming; Xu, Lingfeng; Gong, Dongqin; Lu, Jun

    2010-01-01

    Decomposition experiments conducted with and without microbial processes are commonly used to study the effects of environmental microorganisms on the degradation of organic pollutants. However, the effects of biological pretreatment (sterilization) on organic matter often have a negative impact on such experiments. Based on the principle of water total organic carbon (TOC) analysis, the effects of physical sterilization treatments on determination of TOC and other water quality parameters were investigated. The results revealed that two conventional physical sterilization treatments, autoclaving and 60Co gamma-radiation sterilization, led to the direct decomposition of some organic pollutants, resulting in remarkable errors in the analysis of TOC in water samples. Furthermore, the extent of the errors varied with the intensity and the duration of sterilization treatments. Accordingly, a novel sterilization method for water samples, 0.45 microm micro-filtration coupled with ultraviolet radiation (MCUR), was developed in the present study. The results indicated that the MCUR method was capable of exerting a high bactericidal effect on the water sample while significantly decreasing the negative impact on the analysis of TOC and other water quality parameters. Before and after sterilization treatments, the relative errors of TOC determination could be controlled to lower than 3% for water samples with different categories and concentrations of organic pollutants by using MCUR.

  19. Set Up of an Automatic Water Quality Sampling System in Irrigation Agriculture

    Directory of Open Access Journals (Sweden)

    Emanuel Heinz

    2013-12-01

    Full Text Available We have developed a high-resolution automatic sampling system for continuous in situ measurements of stable water isotopic composition and nitrogen solutes along with hydrological information. The system facilitates concurrent monitoring of a large number of water and nutrient fluxes (ground, surface, irrigation and rain water in irrigated agriculture. For this purpose we couple an automatic sampling system with a Wavelength-Scanned Cavity Ring Down Spectrometry System (WS-CRDS for stable water isotope analysis (δ2H and δ18O, a reagentless hyperspectral UV photometer (ProPS for monitoring nitrate content and various water level sensors for hydrometric information. The automatic sampling system consists of different sampling stations equipped with pumps, a switch cabinet for valve and pump control and a computer operating the system. The complete system is operated via internet-based control software, allowing supervision from nearly anywhere. The system is currently set up at the International Rice Research Institute (Los Baños, The Philippines in a diversified rice growing system to continuously monitor water and nutrient fluxes. Here we present the system’s technical set-up and provide initial proof-of-concept with results for the isotopic composition of different water sources and nitrate values from the 2012 dry season.

  20. Determination of total alpha index in samples of see water by coprecipitation method

    International Nuclear Information System (INIS)

    Suarez-Navarro, J.A.; Pujol, L.; Pozuelo, M.; Pablo, A. de

    1998-01-01

    An environmental radiological monitoring network in the Spanish sea waters was set up by CEDEX in 1993. Water radioactivity is determined quarterly in eleven sampling points along the Spanish coast. The gross alpha activity is one of the parameters to be determined. The usual method for monitoring the gross alpha activity includes sample evaporation to dryness on a disk and counting using ZnS(Ag) scintillation detector. Nevertheless, the gross alpha activity determination in saline waters, such as sea waters, is troublesome, because mass attenuation is high and a very small of water is needed (0.2 ml). The coprecipitation method allows to analyze 500 ml water samples, so the detection limit is reduced and sensitivity is improved. In this work, the coprecipitation method was used to determine the gross alpha activity in the radiological network of the Spanish coast sea waters during 1996 and 1997. Gross alpha activity was very homogenous. It averaged 0.0844±0.0086 Bq.1''1 and ranged from 0.062 to 0.102 Bq.1''1. In collaboration with CIEMAT a set of samples was analyzed, they averaged 0.0689±0.0074 Bq.1''1 and ranged from 0.056 to 0.082 Bq.1''1. (Author) 5 refs

  1. A rapid and sensitive analytical method for the determination of 14 pyrethroids in water samples.

    Science.gov (United States)

    Feo, M L; Eljarrat, E; Barceló, D

    2010-04-09

    A simple, efficient and environmentally friendly analytical methodology is proposed for extracting and preconcentrating pyrethroids from water samples prior to gas chromatography-negative ion chemical ionization mass spectrometry (GC-NCI-MS) analysis. Fourteen pyrethroids were selected for this work: bifenthrin, cyfluthrin, lambda-cyhalothrin, cypermethrin, deltamethrin, esfenvalerate, fenvalerate, fenpropathrin, tau-fluvalinate, permethrin, phenothrin, resmethrin, tetramethrin and tralomethrin. The method is based on ultrasound-assisted emulsification-extraction (UAEE) of a water-immiscible solvent in an aqueous medium. Chloroform was used as extraction solvent in the UAEE technique. Target analytes were quantitatively extracted achieving an enrichment factor of 200 when 20 mL aliquot of pure water spiked with pyrethroid standards was extracted. The method was also evaluated with tap water and river water samples. Method detection limits (MDLs) ranged from 0.03 to 35.8 ng L(-1) with RSDs values or =0.998. Recovery values were in the range of 45-106%, showing satisfactory robustness of the method for analyzing pyrethroids in water samples. The proposed methodology was applied for the analysis of river water samples. Cypermethrin was detected at concentration levels ranging from 4.94 to 30.5 ng L(-1). Copyright 2010 Elsevier B.V. All rights reserved.

  2. Reduction of Powerplex(®) Y23 reaction volume for genotyping buccal cell samples on FTA(TM) cards.

    Science.gov (United States)

    Raziel, Aliza; Dell'Ariccia-Carmon, Aviva; Zamir, Ashira

    2015-01-01

    PowerPlex(®) Y23 is a novel kit for Y-STR typing that includes new highly discriminating loci. The Israel DNA Database laboratory has recently adopted it for routine Y-STR analysis. This study examined PCR amplification from 1.2-mm FTA punch in reduced volumes of 5 and 10 μL. Direct amplification and washing of the FTA punches were examined in different PCR cycle numbers. One short robotically performed wash was found to improve the quality and the percent of profiles obtained. The optimal PCR cycle number was determined for 5 and 10 μL reaction volumes. The percent of obtained profiles, color balance, and reproducibility were examined. High-quality profiles were achieved in 90% and 88% of the samples amplified in 5 and 10 μL, respectively, in the first attempt. Volume reduction to 5 μL has a vast economic impact especially for DNA database laboratories. © 2014 American Academy of Forensic Sciences.

  3. Ultrasonic-energy enhance the ionic liquid-based dual microextraction to preconcentrate the lead in ground and stored rain water samples as compared to conventional shaking method.

    Science.gov (United States)

    Nizamani, Sooraj; Kazi, Tasneem G; Afridi, Hassan I

    2018-01-01

    An efficient preconcentration technique based on ultrasonic-assisted ionic liquid-based dual microextraction (UA-ILDµE) method has been developed to preconcentrate the lead (Pb +2 ) in ground and stored rain water. In the current proposed method, Pb +2 was complexed with a chelating agent (dithizone), whereas an ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was used for extraction purpose. The ultrasonic irradiation and electrical shaking system were applied to enhance the dispersion and extraction of Pb +2 complex in aqueous samples. For second phase, dual microextraction (DµE phase), the enriched Pb +2 complex in ionic liquid, extracted back into the acidic aqueous solution and finally determined by flame atomic absorption spectrometry. Some major analytical parameters that influenced the extraction efficiency of developed method, such as pH, concentration of ligand, volume of ionic liquid and samples, time of shaking in thermostatic electrical shaker and ultrasonic bath, effect of back extracting HNO 3 volume, matrix effect, centrifugation time and rate were optimized. At the sample volume of 25mL, the calculated preconcentration factor was 62.2. The limit of detection of proposed procedure for Pb +2 ions was found to be 0.54μgL -1 . The validation of developed method was performed by the analysis of certified sample of water SRM 1643e and standard addition method in a real water sample. The extraction recovery of Pb +2 was enhanced≥2% with shaking time of 80s in ultrasonic bath as compared to used thermostatic electrical shaker, where for optimum recovery up to 10min was required. The developed procedure was successfully used for the enrichment of Pb +2 in ground and stored rain water (surface water) samples of an endemic region of Pakistan. The resulted data indicated that the ground water samples were highly contaminated with Pb +2 , while some of the surface water samples were also have higher values of Pb +2 than permissible limit of

  4. Water-quality assessment of south-central Texas : comparison of water quality in surface-water samples collected manually and by automated samplers

    Science.gov (United States)

    Ging, Patricia B.

    1999-01-01

    Surface-water sampling protocols of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program specify samples for most properties and constituents to be collected manually in equal-width increments across a stream channel and composited for analysis. Single-point sampling with an automated sampler (autosampler) during storms was proposed in the upper part of the South-Central Texas NAWQA study unit, raising the question of whether property and constituent concentrations from automatically collected samples differ significantly from those in samples collected manually. Statistical (Wilcoxon signed-rank test) analyses of 3 to 16 paired concentrations for each of 26 properties and constituents from water samples collected using both methods at eight sites in the upper part of the study unit indicated that there were no significant differences in concentrations for dissolved constituents, other than calcium and organic carbon.

  5. Determination of radiocaesium in agriculture-related water samples containing suspended solids using gelling method

    International Nuclear Information System (INIS)

    Matsunami, Hisaya; Shin, Moono; Takahashi, Yoshihiko; Shinano, Takuro; Kitajima, Shiori; Tsuchiya, Takashi

    2015-01-01

    After the TEPCO Fukushima Dai-ichi Nuclear Power Plant accident in 2011, the radiocaesium, which flowed into the paddy fields via irrigation water, have been widely investigated. When the concentration of radiocaesium in the water samples containing suspended solids were directly measured using a high purity germanium detector with a 2 L marinelli beaker, the radiocaesium concentration might be overestimated due to the sedimentation of the suspended solids during the measurement time. In fact, the values obtained by the direct method were higher than those obtained by the filtering method and/or the gelling method in most of the agriculture-related water samples. We concluded that the gelling method using sodium polyacrylate can be widely adapted for the analysis of the total radiocaesium in the agriculture-related water samples because of its many advantage such as simple preparation procedure, accurate analysis values, excellent long-term stability of geometry and low operating cost. (author)

  6. Analysis of bromate in drinking water using liquid chromatography-tandem mass spectrometry without sample pretreatment.

    Science.gov (United States)

    Kosaka, Koji; Asami, Mari; Takei, Kanako; Akiba, Michihiro

    2011-01-01

    An analytical method for determining bromate in drinking water was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The (18)O-enriched bromate was used as an internal standard. The limit of quantification (LOQ) of bromate was 0.2 µg/L. The peak of bromate was separated from those of coexisting ions (i.e., chloride, nitrate and sulfate). The relative and absolute recoveries of bromate in two drinking water samples and in a synthesized ion solution (100 mg/L chloride, 10 mg N/L nitrate, and 100 mg/L sulfate) were 99-105 and 94-105%, respectively. Bromate concentrations in 11 drinking water samples determined by LC-MS/MS were water without sample pretreatment.

  7. May 2013 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

    Energy Technology Data Exchange (ETDEWEB)

    Hutton, Rick [S.M. Stoller Corporation, Broomfield, CO (United States)

    2013-10-01

    Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 14-16, 2013, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location CER #1 Black Sulphur. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry and for tritium using the conventional and enrichment methods.

  8. Wadter Resources Data Ohio: Water year 1994. Volume 2, St. Lawrence River Basin and Statewide Project Data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Water Resources Division of the US Geological Survey (USGS), in cooperation with State agencies, obtains a large amount of data each water year (a water year is the 12-month period from October 1 through September 30 and is identified by the calendar year in which it ends) pertaining to the water resources of Ohio. These data, accumulated during many years, constitute a valuable data base for developing an improved understanding of the water resources of the State. To make these data readily available to interested parties outside the USGS, they are published annually in this report series entitled ``Water Resources Data--Ohio.`` This report (in two volumes) includes records on surface water and ground water in the State. Specifically, it contains: (1) Discharge records for streamflow-gaging stations, miscellaneous sites, and crest-stage stations; (2) stage and content records for streams, lakes, and reservoirs; (3) water-quality data for streamflow-gaging stations, wells, synaptic sites, and partial-record sites; and (4) water-level data for observation wells. Locations of lake- and streamflow-gaging stations, water-quality stations, and observation wells for which data are presented in this volume are shown in figures ga through 8b. The data in this report represent that part of the National Water Data System collected by the USGS and cooperating State and Federal agencies in Ohio. This series of annual reports for Ohio began with the 1961 water year with a report that contained only data relating to the quantities of surface water. For the 1964 water year, a similar report was introduced that contained only data relating to water quality. Beginning with the 1975 water year, the report was changed to present (in two to three volumes) data on quantities of surface water, quality of surface and ground water, and ground-water levels.

  9. Operation, Maintenance and Performance Evaluation of the Potomac Estuary Experimental Water Treatment Plant. Main Volume.

    Science.gov (United States)

    1983-09-01

    was stained with Lugol’s or D’Antonlo’s iodine stain and then examined microscopically for Giardia cysts, Entamoeba histolytica, Acanthamoeba...five-tube ..ON procedure was used for quantitating Salmonella sp . in water. The enrichmentp isolation and primary biochemical test methods are found in...8217 . . ..*- * .* . • .* .- .,,.. - ... - . .. .-. * . . . .- . ....... .. .. . . .i. . -. ’.. IO. Sampling Began I I , ta . __ _ _ _ __ _ _ _ a Grab Samples taken at 4 PM 88. I -MAR I -JUN I-SEP IDEC I-PAR I t- SP

  10. Concentration of polycyclic aromatic hydrocarbons in water samples from different stages of treatment

    Directory of Open Access Journals (Sweden)

    Pogorzelec Marta

    2017-01-01

    Full Text Available The aim of this study was to analyze the presence and concentration of selected polycyclic aromatic hydrocarbons in water