WorldWideScience

Sample records for volume presents results

  1. Development of grout formulations for 106-AN waste: Mixture-experiment results and analysis. Volume 2, Data presentation

    Energy Technology Data Exchange (ETDEWEB)

    Spence, R.D.; McDaniel, E.W. [Oak Ridge National Lab., TN (United States); Anderson, C.M.; Lokken, R.O.; Piepel, G.F. [Pacific Northwest Lab., Richland, WA (United States)

    1993-09-01

    Twenty potential ingredients were identified for use in developing a 106-AN grout formulation, and 18 were subsequently obtained and tested. Four ingredients: Type II-LA (moderate heat of hydration) Portland cement, Class F fly ash, attapulgite 150 drilling clay, and ground air-cooled blast-furnace slag (GABFS) -- were selected for developing the 106-AN grout formulations. A mixture experiment was designed and conducted around the following formulation: 2.5 lb of cement per gallon, 1.2 lb of fly ash per gallon, 0.8 lb of attapulgite per gallon, and 3.5 lb of GABFS per gallon. Reduced empirical models were generated from the results of the mixture experiment. These models were used to recommend several grout formulations for 106-AN. Westinghouse Hanford Company selected one of these formulations to be verified for use with 106-AN and a backup formulation in case problems arise with the first choice. This report presents the mixture-experimental results and leach data.

  2. Large-volume results in SU(2) with adjoint fermions

    CERN Document Server

    Del Debbio, Luigi; Pica, Claudio; Patella, Agostino; Rago, Antonio; Roman, Sabin

    2014-01-01

    Taming finite-volume effects is a crucial ingredient in order to identify the existence of IR fixed points. We present the latest results from our numerical simulations of SU(2) gauge theory with 2 Dirac fermions in the adjoint representation on large volumes. We compare with previous results, and extrapolate to thermodynamic limit when possible.

  3. Large-volume results in SU(2) with adjoint fermions

    DEFF Research Database (Denmark)

    Del Debbio, Luigi; Lucini, Biagio; Pica, Claudio;

    2013-01-01

    Taming finite-volume effects is a crucial ingredient in order to identify the existence of IR fixed points. We present the latest results from our numerical simulations of SU(2) gauge theory with 2 Dirac fermions in the adjoint representation on large volumes. We compare with previous results, an...

  4. How to present and publish research results

    Directory of Open Access Journals (Sweden)

    Dekanski Aleksandar

    2014-01-01

    Full Text Available The end of each research is to present its results to the public, especially to those who are engaged in similar research. This is particularly true for scientific research. Scientific paper is written report that contains a presentation of the results of the original scientific research. Its format is defined by centuries-old tradition of writing, the editorial practices of the publishers, scientific ethics, accepted standards and requirements of modern printing and publishing. Unfortunately, the experience of the publishers and editors of scientific books and journals show that a large number of submitted contributions are not meeting the minimum requirements to be even considered. This article indicates the most important principles that one should have in mind during creation of full text paper or presentation of scientific results.

  5. ISO Results Presented at International Astronomical Union

    Science.gov (United States)

    1997-08-01

    Some of the work being presented is collected in the attached ESA Information Note N 25-97, ISO illuminates our cosmic ancestry. A set of six colour images illustrating various aspects have also been released and are available at http://www.estec.esa.nl/spdwww/iso1808.htm or in hard copy from ESA Public Relations Paris (fax:+33.1.5369.7690). These pictures cover: 1. Distant but powerful infrared galaxies 2. A scan across the milky way 3. Helix nebula: the shroud of a dead star 4. Supernova remnant Cassiopeia A 5. Trifid nebula: a dusty birthplace of stars 6. Precursors of stars and planets The International Astronomical Union provides a forum where astronomers from all over the world can develop astronomy in all its aspects through international co-operation. General Assemblies are held every three years. It is expected that over 1600 astronomers will attend this year's meeting, which is being held in Kyoto, Japan from 18-30 August. Further information on the meeting can be found at: www.tenmon.or.jp/iau97/ . ISO illuminates our cosmic ancestry The European Space Agency's Infrared Space Observatory, ISO, is unmatched in its ability to explore and analyse many of the universal processes that made our existence possible. We are children of the stars. Every atom in our bodies was created in cosmic space and delivered to the Sun's vicinity in time for the Earth's formation, during a ceaseless cycle of birth, death and rebirth among the stars. The most creative places in the sky are cool and dusty, and opaque even to the Hubble Space Telescope. Infrared rays penetrating the dust reveal to ISO hidden objects, and the atoms and molecules of cosmic chemistry. "ISO is reading Nature's recipe book," says Roger Bonnet, ESA's director of science. "As the world's only telescope capable of observing the Universe over a wide range of infrared wavelengths, ISO plays an indispensable part in astronomical discoveries that help to explain how we came to exist." This Information Note

  6. Factors Impacting Habitable Volume Requirements: Results from the 2011 Habitable Volume Workshop

    Science.gov (United States)

    Simon, M.; Whitmire, A.; Otto, C.; Neubek, D. (Editor)

    2011-01-01

    This report documents the results of the Habitable Volume Workshop held April 18-21, 2011 in Houston, TX at the Center for Advanced Space Studies-Universities Space Research Association. The workshop was convened by NASA to examine the factors that feed into understanding minimum habitable volume requirements for long duration space missions. While there have been confinement studies and analogs that have provided the basis for the guidance found in current habitability standards, determining the adequacy of the volume for future long duration exploration missions is a more complicated endeavor. It was determined that an improved understanding of the relationship between behavioral and psychosocial stressors, available habitable and net habitable volume, and interior layouts was needed to judge the adequacy of long duration habitat designs. The workshop brought together a multi-disciplinary group of experts from the medical and behavioral sciences, spaceflight, human habitability disciplines and design professionals. These subject matter experts identified the most salient design-related stressors anticipated for a long duration exploration mission. The selected stressors were based on scientific evidence, as well as personal experiences from spaceflight and analogs. They were organized into eight major categories: allocation of space; workspace; general and individual control of environment; sensory deprivation; social monotony; crew composition; physical and medical issues; and contingency readiness. Mitigation strategies for the identified stressors and their subsequent impact to habitat design were identified. Recommendations for future research to address the stressors and mitigating design impacts are presented.

  7. Small power systems study. Volume. Study results. Technical summary report

    Energy Technology Data Exchange (ETDEWEB)

    Sitney, L.R.

    1978-05-31

    The Division of Solar Technology of the Department of Energy is currently examining the market potential of a number of dispersed solar energy systems, including the small (less than or equal to 10 MW/sub e/) solar thermal power system. Small fossil-fueled generating units in the United States utility system, (i.e., investor-owned, municipal, and cooperatives) have a current capacity of approximately 8000 MW/sub e/ or about 1.5 percent of the total US electrical capacity, and provide a large potential market for small solar thermal power systems. The Small Power Systems Study has as its objective the determination of conditions under which small (less than or equal to 10 MW/sub e/) solar thermal power units can provide cost-effective electrical power to a variety of users. Potential users, in addition to the utility systems; include Department of Defense installations and applications, remote mining and/or lumbering operations, and other industrial power systems with and without cogeneration. The first year's results on the Small Power Systems Study are summarized. The data base used and the breakeven cost analysis are discussed. Information on both small (less than or equal to 10 MW/sub e/) generating units and the utility systems using them is presented as well as data on fossil fuel costs, solar plant costs, and solar insolation values. The results of a survey of Department of Defense (DOD) worldwide electrical generating capacity at its military bases and on a potential DOD application are presented. Information on a potential small solar power system experiment in the interior of Alaska is given, and a limited amount of information on a remote application which would provide power or a large open pit copper mine is presented. Volume II of this Technical Summary Report contains an inventory, by state, of the small (less than or equal to 10 MW/sub e/) generating units in the US utility system. (WHK)

  8. Preliminary Results from the Large Volume Torsion (LVT) Deformation Apparatus

    Science.gov (United States)

    Cross, A. J.; Couvy, H.; Skemer, P. A.

    2015-12-01

    We present preliminary results from the Large Volume Torsion (LVT) apparatus, currently under development in the rock deformation lab at Washington University in St. Louis. The LVT is designed to deform disk-shaped samples (~4 mm in diameter) in torsion at lower-crustal to upper-mantle pressure and temperature conditions. Conceptually, the LVT complements and is similar in design to the Rotational Drickamer Apparatus (RDA) (Yamakazi & Karato, 2001), which deforms smaller samples at higher pressures. As part of our recent development efforts, benchmarking experiments were performed on Carrara marble. Samples were deformed in torsion at a strain rate of ~5 x 10-5 s-1 to moderate shear strains (γ ≤ 10) under lower crustal conditions (800°C, 2 GPa confining pressure). Microstructural observations from optical microscopy and electron backscatter diffraction (EBSD) show evidence for relict grain elongation and alignment; an increase in calcite twin density; and grain size reduction concurrent with recrystallized grain nucleation. Microstructural observations are comparable to data obtained from previous studies at lower pressure (e.g. Barnhoorn et al., 2004), confirming that the LVT provides reliable microstructural results.

  9. [How should the results of a scientific study be presented? I. The oral presentation].

    Science.gov (United States)

    Manterola, Carlos; Pineda, Viviana; Vial, Manuel; Grande, Luis

    2007-01-01

    The results of a research study can be presented through oral communications, posters, conferences and publications, etc. The present article suggests ways in which oral communications and posters can be presented. The sequence of steps leading up to an oral presentation can be divided into writing a summary, designing the graphic material, giving the presentation and defending the results. Posters have a similar structure but this format allows complex experiments to be clearly presented and a variety of illustrations to be introduced, without the strict time constraints that apply to oral presentations. Whichever format is followed, we recommend that authors answer the following questions: what was the question studied and why?, how was it studied?, what were the results?, and what do they mean? These questions help to structure the presentation effectively.

  10. DOE 2009 Geothermal Risk Analysis: Methodology and Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Young, K. R.; Augustine, C.; Anderson, A.

    2010-02-01

    This presentation summarizes the methodology and results for a probabilistic risk analysis of research, development, and demonstration work-primarily for enhanced geothermal systems (EGS)-sponsored by the U.S. Department of Energy Geothermal Technologies Program.

  11. African Primary Care Research: quantitative analysis and presentation of results.

    Science.gov (United States)

    Mash, Bob; Ogunbanjo, Gboyega A

    2014-06-06

    This article is part of a series on Primary Care Research Methods. The article describes types of continuous and categorical data, how to capture data in a spreadsheet, how to use descriptive and inferential statistics and, finally, gives advice on how to present the results in text, figures and tables. The article intends to help Master's level students with writing the data analysis section of their research proposal and presenting their results in their final research report.

  12. African Primary Care Research: Quantitative analysis and presentation of results

    Directory of Open Access Journals (Sweden)

    Bob Mash

    2014-01-01

    Full Text Available This article is part of a series on Primary Care Research Methods. The article describes types of continuous and categorical data, how to capture data in a spreadsheet, how to use descriptive and inferential statistics and, finally, gives advice on how to present the results in text, figures and tables. The article intends to help Master’s level students with writing the data analysis section of their research proposal and presenting their results in their final research report.

  13. The history of NATO TNF policy: The role of studies, analysis and exercises conference proceedings. Volume 2: Papers and presentations

    Energy Technology Data Exchange (ETDEWEB)

    Rinne, R.L.

    1994-02-01

    This conference was organized to study and analyze the role of simulation, analysis, modeling, and exercises in the history of NATO policy. The premise was not that the results of past studies will apply to future policy, but rather that understanding what influenced the decision process -- and how -- would be of value. The structure of the conference was built around discussion panels. The panels were augmented by a series of papers and presentations focusing on particular TNF events, issues, studies, or exercises. The conference proceedings consist of three volumes. Volume 1 contains the conference introduction, agenda, biographical sketches of principal participants, and analytical summary of the presentations and panels. This volume contains a short introduction and the papers and presentations from the conference. Volume 3 contains selected papers by Brig. Gen. Robert C. Richardson III (Ret.). Individual papers in this volume were abstracted and indexed for the database.

  14. Oak Ridge Reservation environmental report for 1992. Volume 2: Data presentation

    Energy Technology Data Exchange (ETDEWEB)

    Koncinski, W.S. [ed.

    1993-09-01

    The two volumes of this report present data and supporting narratives regarding the impact of the US Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) on its environs and the public during 1992. Volume 1 includes all narrative descriptions, summaries, and conclusions and is intended to be a ``stand-alone`` report for the reader who does not want to review in detail all of the 1992 data for the ORR. This volume (volume 2) includes the detailed data in formats that ensure all the environmental data are presented. Narratives are not included in Vol. 2.

  15. Oak Ridge Reservation environmental report for 1992. Volume 2: Data presentation

    Energy Technology Data Exchange (ETDEWEB)

    Koncinski, W.S. [ed.

    1993-09-01

    The two volumes of this report present data and supporting narratives regarding the impact of the US Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) on its environs and the public during 1992. Volume 1 includes all narrative descriptions, summaries, and conclusions and is intended to be a ``stand-alone`` report for the reader who does not want to review in detail all of the 1992 data for the ORR. This volume (volume 2) includes the detailed data in formats that ensure all the environmental data are presented. Narratives are not included in Vol. 2.

  16. Present status and recent results from the APS SASE FEL

    CERN Document Server

    Lewellen, J W; Gluskin, E; Arnold, N D; Benson, C; Berg, W; Biedron, S G; Borland, M; Chae, Y C; Dejus, Roger J; Hartog, P K D; Deriy, B; Erdmann, M; Eidelman, Yu I; Hahne, M W; Huang, Z; Kim, K J; Li, Y; Lumpkin, Alex H; Makarov, O; Moog, E; Nassiri, A; Sajaev, Vadim; Soliday, R; Tieman, B J; Trakhtenberg, E; Vasserman, I B; Vinokurov, N A; Wiemerslage, G; Yang, B X

    2002-01-01

    The Low-Energy Undulator Test Line (LEUTL) at the Advanced Photon Source, Argonne National Laboratory, is intended to demonstrate the basic operation of a SASE-based free-electron laser. Goals include comparison of experimental results with theoretical predictions and scaling laws, identification of problems relevant to fourth-generation light source construction and operation and the means of addressing them, the development of operational and diagnostic techniques to optimize SASE FEL performance and increase repeatability from run to run, and performance of initial pioneering experiments capable of exploiting the unique properties of the laser. The basic layout and operational philosophy of the LEUTL experiment is presented. A summary of past results, including saturation, is reviewed, and a description of recent results is presented. We conclude with future plans, which include pressing to shorter wavelengths and incorporating user experiments into the LEUTL experimental program.

  17. Results and present status of the spectrometer aSPECT

    Energy Technology Data Exchange (ETDEWEB)

    Ayala Guardia, Fidel; Borg, Michael; Glueck, Ferenc; Heil, Werner; Konrad, Gertrud; Munoz Horta, Raquel; Sobolev, Yury [Institut fuer Physik, Universitaet Mainz (Germany); Angerer, Heinz; Konorov, Igor; Petzoldt, Gerd; Simson, Martin; Wirth, Hans-Friedrich; Zimmer, Oliver [Physik Department, Technische Universitaet Muenchen (Germany); Baessler, Stefan [Department of Physics, University of Virginia, Charlottesville (United States); Eberhardt, Klaus [Institut fuer Kernchemie, Universitaet Mainz (Germany)

    2008-07-01

    The aim of the aSPECT spectrometer is a precise measurement of the proton recoil spectrum in free neutron decay. For kinematic reasons, the shape of the proton spectrum depends on the angular correlation coefficient between the momenta of the electron antineutrino and the electron, a. An accurate measurement of the angular correlation coefficient a is of great interest in order to test the unitarity of the Cabibbo Kobayashi Maskawa Matrix (CKM-Matrix). A first test beam time was performed during 2005/06 at the beam line MEPHISTO at the neutron research reactor FRM-II in Garching. Results of the data analysis as well as the present status of the aSPECT spectrometer are presented in this talk.

  18. LHC experiments present new results at Quark Matter 2011 Conference

    CERN Multimedia

    CERN Press Office

    2011-01-01

    The three LHC experiments that study lead ion collisions all presented their latest results today at the annual Quark Matter conference, held this year in Annecy, France. The results are based on analysis of data collected during the last two weeks of the 2010 LHC run, when the LHC switched from protons to lead-ions. All experiments report highly subtle measurements, bringing heavy-ion physics into a new era of high precision studies.   Events recorded by the ALICE experiment from the first lead ion collisions (Nov-Dec 2010). “These results from the LHC lead ion programme are already starting bring new understanding of the primordial universe,” said CERN Director General Rolf Heuer. “The subtleties they are already seeing are very impressive.” In its infancy, just microseconds after the Big Bang, the universe consisted of a plasma of quarks and gluons (QGP), the fundamental building blocks of matter. By colliding heavy ions, physicists can turn back time an...

  19. Utilizing video animation to present FEA (Finite Element Analysis) results

    Energy Technology Data Exchange (ETDEWEB)

    Hayer, L.K.; Vossler, J.J. III.

    1990-01-01

    Finite element Analysis (FEA) technique are used to analyze forming, rolling, extrusion, and other continuous manufacturing processes to produce solutions at discrete points in time. These solutions are then displayed using a graphical post-processor. The post-processor displays one plot at a time making it difficult to follow events over the entire process. A means of linking these images that occur at discrete points in time and displaying them in a continuous fashion would aid in comprehending the significance of dynamic or time dependent events that evolve during the processes. Video recording of the graphics provides a means to link the graphical ouput at each discrete point in time and project the results in a continuous fashion upon playback. This presentation outlines the video hardware, the modifications to the pre- and post-processing software, and the process used to make video animation recording of FEA results. Several examples will be shown: Hydroforming of a Spherical Aluminum Shell'' and Three-Stage Forging.'' 5 refs., 7 figs.

  20. Spacecraft Habitable Volume: Results of an Interdisciplinary Workshop

    Science.gov (United States)

    Fitts, David J.; Connolly, Janis; Howard, Robert

    2011-01-01

    NASA's Human Exploration Framework Team posed the question: "Is 80 cubic meters per person of habitable volume acceptable for a proposed Deep Space Habitat?" The goal of the workshop was to address the "net habitable volume" necessary for long-duration human spaceflight missions and identify design and psychological issues and mitigations. The objectives were: (1) Identify psychological factors -- i.e., "stressors" -- that impact volume and layout specifications for long duration missions (2) Identify mitigation strategies for stressors, especially those that can be written as volume design specifications (3) Identify a forward research roadmap -- i.e., what future work is needed to define and validate objective design metrics? (4) Provide advisories on the human factors consequences of poor net habitable volume allocation and layout design.

  1. Improvements of volume holographic grating in photopolymer doped with nanorods (Conference Presentation)

    Science.gov (United States)

    Cao, Liangcai; Wu, Shenghan; Zong, Song; Zhang, Hao; Jin, Guofan

    2016-09-01

    Enhanced volume holographic refractive index grating by employing a strong volume holographic absorption grating induced by the periodic spatial distribution of gold nanoparticles due to the polymerization-driven multicomponent diffusion in a bulk gold nanoparticles doped photopolymer is noticeable. Till now most works are only focused on changing the concentration of nanoparticles and the radius of sphere nanoparticles. We propose an approach to improve the volume holographic grating by changing the size and shape of doped nanoparticles. The difference between nanorods and nanospheres is analyzed by the finite difference time domain(FDTD) method and the holographic kinetic model. The simulation results indicate that the nanorods has stronger localized surface plasmon resonance effect. The size and the aspect ratio of gold nanorods are optimized for the best absorption at a certain wavelength of recording light. The experiment results verify that the nanoparticles can be designed to achieve higher diffraction efficiency in a mixed volume holographic grating.

  2. The comeback of the psychology of religion: the aims of the present volume

    NARCIS (Netherlands)

    Belzen, J.A.; Belzen, J.A.

    2012-01-01

    "The psychology of religion is back. It is alive and kicking!" If that were the main message of the present volume, or even of this introduction, one would immediately need to raise some critical questions. We should at least ask why this assertion should count as special, as something worth mention

  3. [Clinical presentation and coronary angiographic results in unstable angina pectoris].

    Science.gov (United States)

    Weber, T; Kirchgatterer, A; Auer, J; Wimmer, L; Lang, G; Mayr, H; Maurer, E; Punzengruber, C; Eber, B

    1999-01-01

    The syndrome "unstable angina" (UA) covers a broad spectrum of patients. In this study we tried to determine the relationship between the severity of UA and angiographic findings. We evaluated 1000 consecutive patients undergoing coronary angiography. Those with the clinical diagnosis "UA" were included in the study. In a retrospective analysis of their records we categorized them, using the Braunwald-classification for determination of the severity of the disease. 352 patients were include, 209 men and 143 women, the mean age was 65 years. 47% met Braunwald-Class I, 26% Class II and 27% Class III. Coronary single-vessel disease was present in 29%, two-vessel disease in 20%, three-vessel disease in 25%, normal coronaries in 13% and coronary atherosclerosis without critical narrowing in 13%. Left ventricular function was preserved in 72%, mild systolic dysfunction was found in 10%, moderate in 13% and severe in 5%. There was no overall correlation between clinical presentation (Braunwald-Classes) and angiographic findings. Women showed a similar distribution of Braunwald-Classes, but significantly more coronary arteries without critical obstruction. In patients with reduced systolic function the percentage of multi-vessel disease was significantly higher, the percentage without relevant coronary artery narrowing was significantly lower. 1) The lack of overall correlation between clinical presentation and angiographic findings supports the importance of coronary angiography in the evaluation of patients with UA. 2) The assessment of women with chest pain is more difficult than of men with regard to coronary heart disease. 3) UA in patients with impaired left ventricular function is a predictor of severe coronary artery disease.

  4. Unusual presentation of a pancreatic cyst resulting from osteosarcoma metastasis.

    Science.gov (United States)

    Akpinar, Burcu; Obuch, Joshua; Fukami, Norio; Pokharel, Sajal S

    2015-07-21

    Pancreatic metastases are uncommon. They have been reported in lung cancer, gastrointestinal malignancies, breast cancer, renal cell carcinoma, melanoma, lymphoma and sarcoma, and usually have solid morphology. Cystic metastasis to the pancreas is even more rare with few case reports in the literature. However, with the increasing use of computed tomography and magnetic resonance imaging as well as endoscopic ultrasound, more such lesions may be detected. Metastasis to the pancreas from osteosarcoma is highly unusual, but can be seen with the increasing survival of patients with osteosarcoma. We present an extremely rare case of a predominantly cystic lesion of the pancreas, which was diagnosed as metastasis from osteosarcoma. The pathophysiology of the cystic component of the metastasis of osteosarcoma is unknown. Cystic necrotic degeneration of the solid metastasis or pancreatitis secondary to the metastasis with development of associated fluid collection can be considered. Metastasis should remain a differential consideration even for primarily cystic lesions of the pancreas.

  5. Presentation of RTE results 2003; Bilan electrique francais 2003

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    In 2003, RTE recorded a clear improvement in its financial results, and continued its debt reduction programme. The financial year 2003 was marked by a clear improvement in RTE's financial performance: results exceeded objectives, with turnover growing strongly, net income reached levels almost three times higher than those recorded in 2002, the economic rate of return rose to 7.1%, and debt was reduced by 470 Meuros. These results are explained by the substantial improvement in productivity, which has risen by 5% per year on average over the last three years. Net income has almost tripled due to RTE's improved productivity completed by a significant rise in its turnover and stabilizing operating costs RTE's finances therefore remain healthy, enabling the company to continue its debt reduction programme. Satisfactory economic and financial rates of return. Deadlines facing RTE in 2004: in application of the second European Directive, adopted on 26 June 2003, RTE faces two major deadlines in 2004: - the implementation of the 2. phase in the process of opening up the French electricity market, - its legal independence. On 1 July 2004, the market will be opened up to competition for all professional customers. At that date RTE, like all other electricity transmission system operators (TSOs) in the European Union, should be a legally independent body. The new central role of TSOs in Europe: how are electricity transmission system operators in other EU countries organised?.

  6. Do intravascular hypo- and hypervolaemia result in changes in central blood volumes?

    NARCIS (Netherlands)

    Vos, J. J.; Scheeren, T. W. L.; Loer, S. A.; Hoeft, A.; Wietasch, J. K. G.

    2016-01-01

    Background: Hypovolaemia is generally believed to induce centralization of blood volume. Therefore, we evaluated whether induced hypo-and hypervolaemia result in changes in central blood volumes (pulmonary blood volume (PBV), intrathoracic blood volume (ITBV)) and we explored the effects on the dist

  7. Presentation of RTE results 2003; Presentation des resultats 2003 de RTE

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    For RTE, the financial year 2003 was marked by a number of achievements: our financial performances registered a clear improvement, above objectives, with turnover growing strongly; net income reached levels almost three times higher than those recorded in 2002; the economic rate of return rose to 7.1%; and debt was reduced by 470 Meuros. These results are explained by the substantial improvement in productivity, which has risen by 5% per year on average over the last three years.

  8. Mars power system concept definition study. Volume 1: Study results

    Science.gov (United States)

    Littman, Franklin D.

    1994-12-01

    A preliminary top level study was completed to define power system concepts applicable to Mars surface applications. This effort included definition of power system requirements and selection of power systems with the potential for high commonality. These power systems included dynamic isotope, Proton Exchange Membrane (PEM) regenerative fuel cell, sodium sulfur battery, photovoltaic, and reactor concepts. Design influencing factors were identified. Characterization studies were then done for each concept to determine system performance, size/volume, and mass. Operations studies were done to determine emplacement/deployment maintenance/servicing, and startup/shutdown requirements. Technology development roadmaps were written for each candidate power system (included in Volume 2). Example power system architectures were defined and compared on a mass basis. The dynamic isotope power system and nuclear reactor power system architectures had significantly lower total masses than the photovoltaic system architectures. Integrated development and deployment time phasing plans were completed for an example DIPS and reactor architecture option to determine the development strategies required to meet the mission scenario requirements.

  9. Committee to evaluate Sandia`s risk expertise: Final report. Volume 1: Presentations

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, E.C.

    1998-05-01

    On July 1--2, 1997, Sandia National Laboratories hosted the External Committee to Evaluate Sandia`s Risk Expertise. Under the auspices of SIISRS (Sandia`s International Institute for Systematic Risk Studies), Sandia assembled a blue-ribbon panel of experts in the field of risk management to assess their risk programs labs-wide. Panelists were chosen not only for their own expertise, but also for their ability to add balance to the panel as a whole. Presentations were made to the committee on the risk activities at Sandia. In addition, a tour of Sandia`s research and development programs in support of the US Nuclear Regulatory Commission was arranged. The panel attended a poster session featuring eight presentations and demonstrations for selected projects. Overviews and viewgraphs from the presentations are included in Volume 1 of this report. Presentations are related to weapons, nuclear power plants, transportation systems, architectural surety, environmental programs, and information systems.

  10. Structured assessment approach: Version I. Applied demonstration of output results. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    Parziale, A.A.; Sacks, 1.J.

    1979-10-01

    A methodology, the Structured Assessment Approach, has been developed for the assessment of the effectiveness of material control and accounting (MC and A) safeguards systems at nuclear fuel cycle facilities. This methodology has been refined into a computational tool, the SAA Version 1 computational package, that was used first to analyze a hypothetical fuel cycle facility (HFCF) and used more recently to assess operational nuclear plants. The Version 1 analysis package is designed to analyze safeguards systems that prevent the diversion of special nuclear material (SNM) from nuclear fuel cycle facilities and to provide assurance that diversion has not occurred. This report is the third volume, Applied Demonstration of Output Results, of a four-volume document. It presents the outputs for each of the four levels of the SAA Version 1 computational package. Two types of outputs are discussed: detailed output findings and summary output tables. The summary output tables are used to aggregate the detailed output findings in a condensed form for NRC analyst consumption. Specific output results are presented for an HFCF, which is described in Volume II.

  11. Evaluation of registration, compression and classification algorithms. Volume 1: Results

    Science.gov (United States)

    Jayroe, R.; Atkinson, R.; Callas, L.; Hodges, J.; Gaggini, B.; Peterson, J.

    1979-01-01

    The registration, compression, and classification algorithms were selected on the basis that such a group would include most of the different and commonly used approaches. The results of the investigation indicate clearcut, cost effective choices for registering, compressing, and classifying multispectral imagery.

  12. PISA 2015 Results: Students' Financial Literacy. Volume IV

    Science.gov (United States)

    OECD Publishing, 2017

    2017-01-01

    The OECD Programme for International Student Assessment (PISA) examines not just what students know in science, reading and mathematics, but what they can do with what they know. Results from PISA show educators and policy makers the quality and equity of learning outcomes achieved elsewhere, and allow them to learn from the policies and practices…

  13. Rocket injector anomalies study. Volume 2: Results of parametric studies

    Science.gov (United States)

    Przekwas, A. J.; Singhal, A. K.; Tam, L. T.

    1984-01-01

    The employment of a existing computer program to simulate three dimensional two phase gas spray flows in liquid propellant rocket engines. This was accomplished by modification of an existing three dimensional computer program (REFLAN3D) with Euler/Lagrange approach for simulating two phase spray flow, evaporation and combustion. The modified code is referred to as REFLAN3D-SPRAY. Computational studies of the model rocket engine combustion chamber are presented. The parametric studies of the two phase flow and combustion shows qualitatively correct response for variations in geometrical and physical parameters. The injection nonuniformity test with blocked central fuel injector holes shows significant changes in the central flame core and minor influence on the wall heat transfer fluxes.

  14. 1996 prairie grouse breeding ground count results and discussion of results 1956-present

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This document is results of the 1996 prairie grouse breeding ground count conducted on Fort Niobrara National Wildlife Refuge in April 1996. It contains a discussion...

  15. Cryogenic tests of volume-phase holographic gratings: results at 100 K

    CERN Document Server

    Tamura, N; Luke, P; Blackburn, C; Robertson, D J; Dipper, N A; Sharples, R M; Allington-Smith, J R; Tamura, Naoyuki; Murray, Graham J.; Luke, Peter; Blackburn, Colin; Robertson, David J.; Dipper, Nigel A.; Sharples, Ray M.; Allington-Smith, Jeremy R.

    2006-01-01

    We present results from cryogenic tests of Volume-Phase Holographic(VPH) gratings at 100 K. The aims of these tests are to see whether the diffraction efficiency as a function of wavelength is significantly different at a low temperature from that at room temperature and to see how the performance of a VPH grating is affected by a number of thermal cycles. We have completed 10 cycles between room temperature and 100 $K$, and find no clear evidence that the diffraction efficiency changes with temperature or with successive thermal cycle.

  16. Molecular Profiling and Clinical Outcome of High-Grade Serous Ovarian Cancer Presenting with Low- versus High-Volume Ascites

    Directory of Open Access Journals (Sweden)

    Tomer Feigenberg

    2014-01-01

    Full Text Available Epithelial ovarian cancer consists of multiple histotypes differing in etiology and clinical course. The most prevalent histotype is high-grade serous ovarian cancer (HGSOC, which often presents at an advanced stage frequently accompanied with high-volume ascites. While some studies suggest that ascites is associated with poor clinical outcome, most reports have not differentiated between histological subtypes or tumor grade. We compared genome-wide gene expression profiles from a discovery cohort of ten patients diagnosed with stages III-IV HGSOC with high-volume ascites and nine patients with low-volume ascites. An upregulation of immune response genes was detected in tumors from patients presenting with low-volume ascites relative to those with high-volume ascites. Immunohistochemical studies performed on tissue microarrays confirmed higher expression of proteins encoded by immune response genes and increased tumorinfiltrating cells in tumors associated with low-volume ascites. Comparison of 149 advanced-stage HGSOC cases with differential ascites volume at time of primary surgery indicated low-volume ascites correlated with better surgical outcome and longer overall survival. These findings suggest that advanced stage HGSOC presenting with low-volume ascites reflects a unique subgroup of HGSOC, which is associated with upregulation of immune related genes, more abundant tumor infiltrating cells and better clinical outcomes.

  17. EVALUATION OF VAPOR EQUILIBRATION AND IMPACT OF PURGE VOLUME ON SOIL-GAS SAMPLING RESULTS

    Science.gov (United States)

    Sequential sampling was utilized at the Raymark Superfund site to evaluate attainment of vapor equilibration and the impact of purge volume on soil-gas sample results. A simple mass-balance equation indicates that removal of three to five internal volumes of a sample system shou...

  18. Discovery: Faculty Publications and Presentations, Fiscal Year 1980. Volume 1. Books, Texts, Manuals, Chapters, Papers, Reports, and Presentations

    Science.gov (United States)

    1980-09-01

    with the conclusion that Air Force PME is more than executive development. b. "Blue Tube-A Total Learning Environment." Educaional and Industrial...Army War College. Carlisle Barracks. PA (I I May 80). The presentation in its various formns dealt with concerns for moral standards in American

  19. The pressure-volume relationship of the heart: past, present and future.

    Science.gov (United States)

    Sunagawa, Kenji

    2010-01-01

    The pressure-volume relationship of the heart was first reported more than a century ago. It was not widely accepted, however, until the mid-1970s. The pressure-volume diagram became a central theme of cardiac mechanics once it was shown to be a good representation of ventricular mechanics. Early in 1980s, the introduction of the ventricular interaction with afterload using effective arterial elastance made it possible to translate ventricular mechanical properties represented by the pressure-volume relationship to the pumping ability of the heart. Furthermore incorporating the framework of ventricular arterial interaction into the classic Guyton's circulatory equilibrium early in 2000s enabled us to express quantitatively how mechanical properties of the ventricles and vascular systems determine the circulatory equilibrium. Successful quantitative descriptions of circulatory equilibrium using the pressure-volume concept would promote basic cardiovascular physiology and accelerate its clinical applications.

  20. Luminescence and photosynthesis of marine phytoplankton - a brief presentation of new results

    Directory of Open Access Journals (Sweden)

    Bogdan Wo¼niak

    2000-06-01

    Full Text Available This volume contains a set of eight papers presenting the results of the latest research into the interaction of light with marine phytoplankton by teams from the Marine Physics Department at the IO PAS in Sopot, and the Department of Environmental Physics at the Pedagogical University of Slupsk. These results were presented at the 'Second Workshop on Luminescence and Photosynthesis of Marine Phytoplankton' (Sopot-Paraszyno, 11-15 October 1999 sponsored by the Polish State Committee for Scientific Research. This introductory article discusses the most important assumptions and objectives of the research, and outlines the latest results. These are subsequently discussed in detail in the following papers: (1 Majchrowski & Ostrowska, Influence of photo- and chromatic acclimation on pigment composition in the sea, (2 Wozniak et al., Model of the 'in vivo' spectral absorption of algal pigments. Part 1. Mathematical apparatus, (3 Majchrowski et al., Model of the 'in vivo'spectral absorption of algal pigments. Part 2. Practical applications of the model, (4 Ostrowska et al., Variability of the specific fluorescence of chlorophyll in the ocean. Part 1. Theory of classical 'in situ' chlorophyll fluorometry, (5 Ostrowska et al., Variability of the specific fluorescence of chlorophyll in the ocean. Part 2. Fluorometric method of chlorophyll a determination, (6 Ficek et al., Influence of non-photosynthetic pigments on the measured quantum yield of photosynthesis, (7 Ficek et al., Variability of the portion of functional PS2 reaction centres in the light of a fluorometric study. For the reader's convenience, we append a list of the symbols denoting the physical quantities used in the texts. The nomenclature and denotations are in line with the conventions employed in the subject literature.

  1. Clinical and radiological evaluation of sinus-lifting results with digital volume tomography

    OpenAIRE

    A.M. Panin; A.Yu. Vasiljev; Vishnyakov, V.V.; N.S. Serova; A.A. Kharlamov

    2010-01-01

    Modern techniques of radiological examination form the basis for additional diagnostic and planning methods of surgical treatment in oral surgery and implantology. Assessment of maxillary sinus condition and sinuslifting results is a part of preoperative examination before dental implantation. The estimated results of digital volume tomography after sinuslifting have shown that 51,1% of patients have lack of volume of implant on the medial wall of the sinus. That does not allow placing dental...

  2. Alligator Rivers Analogue project. Geochemical modelling of present-day groundwaters. Final Report - Volume 12

    Energy Technology Data Exchange (ETDEWEB)

    Sverjensky, D. A. [The John Hopkins Univ, Dept of Earth and Planetary Sciences, Baltimore (United States)

    1992-12-31

    The main purpose of this report is to summarize geochemical modeling studies of the present-day Koongarra groundwaters. Information on the present-day geochemistry and geochemical processes at Koongarra forms a basis for a present-day analogue for nuclear waste migration. The present-day analogue is built on studies of the mineralogy and petrology of the Koongarra deposit, and chemical analyses of present-day groundwaters from the deposit. The overall approach taken in the present study has been to carry out a series of aqueous speciation and state of saturation calculations, including chemical mass transfer calculations, to address the possible control over the chemistry of the present-day for the groundwaters at Koongarra. The most important implication of the present study for the migration of radionuclides is the strong role played by the water-rock interactions, both above and below the water table, influencing the overall chemical evolution of the groundwaters. Thus, the results show that the chemical evolution of waters is strongly controlled by the initial availability of CO{sub 2} and the mineral assemblage encountered, which together determine the major element evolution of the waters by controlling the pH. The relative rates of evolution of the pH and the oxidation state of the groundwaters are also critical to the mobility of uranium. The shallow Koongarra waters are sufficiently oxidising that they can dissolve and transport uranium even under acidic conditions. Under the more reducing condition of the deep groundwaters, is the pH level that permits uranium transport as carbonate complexes. However, if the oxidation state decreases to much lower levels, it would be expected that uranium become immobile. All the speciation and state of saturation calculations carried out in the present study are available from the author, on request 22 refs., 7 tabs., 18 figs.

  3. Coal-water-slurry evaluation. Volume 2. Laboratory and combustion test results. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Daley, R.D.; Farthing, G.A.; Vecci, S.J.

    1984-02-01

    This is the second of three volumes describing a multi-phase coal-water slurry (CWS) test program. This volume presents the results of laboratory, atomization, and combustion tests which were performed on six slurries and their parent coals. The objectives of these tests was to establish laboratory test procedures for evaluating CWS fuels, to investigate relationships between laboratory properties and CWS combustion and handling characteristics and to develop preliminary guidelines for CWS specifications. These tests showed that the preparation processes and chemical additives used by the slurry manufacturers had a significant effect on viscosity and atomization properties. The most important factor for good combustion performance was droplet size, but droplet size did not correlate with viscosity measured at low shear rates in the laboratory tests. It was also found that some slurries had greater fouling potential than their parent coals due to the use of sodium-containing additives. Tests were also conducted to determine whether the slurries could be transported and stored without coal settling. These tests showed that little settling occurred during either transportation or storage for at least three weeks. 98 figures, 27 tables.

  4. Feasibility study for biomass power plants in Thailand. Volume 2. appendix: Detailed financial analysis results. Export trade information

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This study, conducted by Black & Veatch, was funded by the U.S. Trade and Development Agency. The report presents a technical and commercial analysis for the development of three nearly identical electricity generating facilities (biomass steam power plants) in the towns of Chachgoengsao, Suphan Buri, and Pichit in Thailand. Volume 2 of the study contains the following appendix: Detailed Financial Analysis Results.

  5. Presentation

    Directory of Open Access Journals (Sweden)

    Eduardo Vicente

    2013-06-01

    effectivities more than a number of fixed essential characteristics. Luiz Artur Ferrareto (UFRGS, undertaking a theoretical proposal for categorizing radio content in four different levels of planning (segment, form, programming and content itself tries to “compare and contrast the practices of Brazilian commercial broadcasting companies to those used on the radio in the United States, a reference market for our national entrepreneurs”. Madalena Oliveira (University of Minho focuses on the current stage of communication researches in Portugal reflecting on the challenges for studying a culture based on listening in times of looking. Marko Ala-Fossi, (University of Tampere beginning with the statement that “radio evolution greatly depends not only on the cultural context of a country but also on the whole social, political, economic development of societies” gives us a projection on radio development around the world for the next decades. Closing the dossier, Rafael Duarte Oliveira Venancio (UFU assuming radio as language by definition and not as a device understands it as a section and an operating model in such language as it intersects the world. Another six articles, not enrolled in the dossier, round the edition off. Fernando de Tacca debates the category of “photocine” recurring to three recent Spanish productions. Gustavo Souza investigates the possibility of identifying a point of view in documentary movies while establishing a debate that joins the materialities of image and sound with the subjectivity resulting from interpretation. Vinicius Bandeira develops on the special duplicity present in the movies between what is and what is not subsumed by the camera. Neide Jallageas proposes the study of visual communication design from the first modelings, attempting especially to the radical propositions from the early XXth century avant-garde movement. Gilson Schwartz debates on the impact from the distribution of videogames as hegemonic cultural practice in

  6. Cryogenic Tests of Volume-Phase Holographic Gratings: I. Results at 200 K

    CERN Document Server

    Tamura, N; Luke, P N; Blackburn, C; Robertson, D J; Dipper, N A; Sharples, R M; Allington-Smith, J R; Tamura, Naoyuki; Murray, Graham J.; Luke, Peter; Blackburn, Colin; Robertson, David J.; Dipper, Nigel A.; Sharples, Ray M.; Allington-Smith, Jeremy R.

    2003-01-01

    We present results from cryogenic tests of a Volume-Phase Holographic (VPH) grating at 200 K measured at near-infrared wavelengths. The aims of these tests were to see whether the diffraction efficiency and angular dispersion of a VPH grating are significantly different at a low temperature from those at a room temperature, and to see how many cooling and heating cycles the grating can withstand. We have completed 5 cycles between room temperature and 200 K, and find that the performance is nearly independent of temperature, at least over the temperature range which we are investigating. In future, we will not only try more cycles between these temperatures but also perform measurements at a much lower temperature (e.g., 80 K).

  7. Conceptual design and systems analysis of photovoltaic systems. Volume II. Study results. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kirpich, A.

    1977-03-19

    This investigation of terrestrial PV systems considered the technical and economic feasibility for systems in three size categories: a small system of about 12 kW peak output for on-site residential use; a large 1500 MW central power plant contributing to the bulk energy of a utility system power grid; and an intermediate size system of about 250 kW for use on public or commercial buildings. In each category, conceptual designs were developed, performance was analyzed for a range of climatic regions, economic analyses were performed, and assessments were made of pertinent institutional issues. The report consists of three volumes. Volume I contains a Study Summary of the major study results. This volume contains the detailed results pertaining to on-site residential photovoltaic systems, central power plant photovoltaic systems, and intermediate size systems applied to commercial and public buildings. Volume III contains supporting appendix material. (WHK)

  8. Fluorescence exclusion: A simple versatile technique to calculate cell volumes and local heights (Conference Presentation)

    Science.gov (United States)

    Thouvenin, Olivier; Fink, Mathias; Boccara, A. Claude

    2017-02-01

    Understanding volume regulation during mitosis is technically challenging. Indeed, a very sensitive non invasive imaging over time scales ranging from seconds to hours and over large fields is required. Therefore, Quantitative Phase Imaging (QPI) would be a perfect tool for such a project. However, because of asymmetric protein segregation during mitosis, an efficient separation of the refractive index and the height in the phase signal is required. Even though many strategies to make such a separation have been developed, they usually are difficult to implement, have poor sensitivity, or cannot be performed in living cells, or in a single shot. In this paper, we will discuss the use of a new technique called fluorescence exclusion to perform volume measurements. By coupling such technique with a simultaneous phase measurement, we were also able to recover the refractive index inside the cells. Fluorescence exclusion is a versatile and powerful technique that allows the volume measurement of many types of cells. A fluorescent dye, which cannot penetrate inside the cells, is mixed with the external medium in a confined environment. Therefore, the fluorescent signal depends on the inverse of the object's height. We could demonstrate both experimentally and theoretically that fluorescence exclusion can accurately measure cell volumes, even for cells much higher than the depth of focus of the objective. A local accurate height and RI measurement can also be obtained for smaller cells. We will also discuss the way to optimize the confinement of the observation chamber, either mechanically or optically.

  9. Presentation

    Directory of Open Access Journals (Sweden)

    Paulo Henrique Freire Vieira

    2013-12-01

    Full Text Available This dossier focuses on one of the essential debate topics today about the territorial dimension of the new development strategies concerned with the worsening of the global socioecological crisis, that is: the challenges related to the activation and integration in networks of localized agri-food systems. For its composition, some contributions presented and debated during the VI International Conference on Localized Agri-food System - The LAFS facing the opportunities and challenges of the new global context have been gathered. The event took place in the city of Florianópolis, from May 21th to 25th of 2013. The event was promoted by the Federal University of Santa Catarina (UFSC and by the Center for the International Cooperation on Agricultural Research for Development (CIRAD. Besides UFSC and CIRAD, EPAGRI, State University of Santa Catarina (UDESC, as well as research institutes and universities from other states (UFMG, IEA/SP, UFS, UFRGS and Mexican and Argentinian partners from the RED SIAL Latino Americana also participated in the organization of lectures, discussion tables and workshops.

  10. Hippocampal brain volume is associated with faster facial emotion identification in older adults: preliminary results

    Directory of Open Access Journals (Sweden)

    Sarah M Szymkowicz

    2016-08-01

    Full Text Available Fast correct identification of facial emotions is highly relevant for successful social interactions. Research suggests that older, compared to young, adults experience increased difficulty with face and emotion processing skills. While functional neuroimaging studies suggest age differences in neural processing of faces and emotions, evidence about age-associated structural brain changes and their involvement in face and emotion processing is scarce. Using structural magnetic resonance imaging, this study investigated the extent to which volumes of frontal and temporal brain structures were related to reaction time in accurate identification of facial emotions in 30 young and 30 older adults. Volumetric segmentation was performed using FreeSurfer and gray matter volumes from frontal and temporal regions were extracted. Analyses of covariance models with response time as the dependent variable and age group and regional volume, and their interaction, as independent variables were conducted, controlling for total intracranial volume. Results indicated that, in older adults, larger hippocampal volumes were associated with faster correct facial emotion identification. These preliminary observations suggest that greater volume in brain regions associated with face and emotion processing contributes to improved facial emotion identification performance in aging.

  11. Hippocampal Brain Volume Is Associated with Faster Facial Emotion Identification in Older Adults: Preliminary Results.

    Science.gov (United States)

    Szymkowicz, Sarah M; Persson, Jonas; Lin, Tian; Fischer, Håkan; Ebner, Natalie C

    2016-01-01

    Quick correct identification of facial emotions is highly relevant for successful social interactions. Research suggests that older, compared to young, adults experience increased difficulty with face and emotion processing skills. While functional neuroimaging studies suggest age differences in neural processing of faces and emotions, evidence about age-associated structural brain changes and their involvement in face and emotion processing is scarce. Using structural magnetic resonance imaging (MRI), this study investigated the extent to which volumes of frontal and temporal brain structures were related to reaction time in accurate identification of facial emotions in 30 young and 30 older adults. Volumetric segmentation was performed using FreeSurfer and gray matter volumes from frontal and temporal regions were extracted. Analysis of covariances (ANCOVAs) models with response time (RT) as the dependent variable and age group and regional volume, and their interaction, as independent variables were conducted, controlling for total intracranial volume (ICV). Results indicated that, in older adults, larger hippocampal volumes were associated with faster correct facial emotion identification. These preliminary observations suggest that greater volume in brain regions associated with face and emotion processing contributes to improved facial emotion identification performance in aging.

  12. Presentation

    Directory of Open Access Journals (Sweden)

    Helmut Renders

    2008-10-01

    Full Text Available We present to our esteemed readers the second edition of our journal for 2008. We have chosen the theme “The life and work of Prof. Dr. Jürgen Moltmann” as its special emphasis. It is our way to pay homage to J. Moltmann in the year the Universidade Metodista de São Paulo awards him an honorary Doctor Honoris Causa degree. Sincethe seventies, Moltmann and Latin America have been in dialog. In his emblematic work “A Theology of Liberation”, Gustavo Gutiérrez, the Catholic, discussed with Moltmann, the Reformed, the relationship between eschatology and history (GUTIÉRREZ, Gustavo.Teologia da Libertação. 5ª edição. Petrópolis, RJ: Vozes, 1985, p. 27, 137-139. A dialog held in the premises of IMS, which nowadays is called UMESP, has produced the little book “Passion for life” (MOLTMANN, Jürgen. Paixão pela vida. São Paulo, SP: ASTE - Associaçãode Seminários Teológicos Evangélicos, 1978.In the following years, the wide theological work of J. Moltmann went all the way from debates to congresses and has conquered the classrooms. Most probably, J. Moltmann is nowadays the most widely read European author in Brazilian theological seminaries. Thisrecognition can only be held in unison and the wide response to our request for articles confirms the huge repercussion that Moltmann’s work has been having up to today in Brazil. The ecumenical theologian J. Moltmann is ecumenically read. We believe that thisway we may be better equipped to answer to anyone who asks us for the reason there is hope in us. We have organized the articles on J. Moltmann’s theology according to the original publication date of the books dealt with in each essay. We also communicate that some articles which were originally requested for this edition of the journal will be published in the journal Estudos de Regilião in May 2009.As it is usual with the journal Caminhando, we have, besides this thematic emphasis, yet other contributions in the areas of

  13. Presentation

    Directory of Open Access Journals (Sweden)

    Nicanor Lopes

    2010-11-01

    Full Text Available The Journal Caminhando debuts with a new editorial format: eachmagazine will have a Dossier.In 2010 Christianity celebrated the centenary of Edinburgh. TheWorld Missionary Conference in Edinburgh in 1910 is regarded by manyas missiological watershed in the missionary and ecumenical movement.So the Faculty of Theology of the Methodist Church (FATEO decidedto organize a Wesleyan Week discussing the issue of mission. For anevent of this magnitude FATEO invited the Rev. Dr. Wesley Ariarajah,Methodist pastor and teacher of Sri Lanka with extensive experience inpastoral ministry in local churches and professor of History of Religionsand the New Testament at the Theological College of Lanka, maintainedby the Protestant Churches in Sri Lanka. In 1981 he was invited to jointhe World Council of Churches, where he presided for over ten years theCouncil of Interreligious Dialogue. From 1992 he served as Deputy GeneralSecretary of the WCC.The following texts are not the speeches of the Rev. Dr. WesleyAriarajah, for they will be published separately. Nevertheless, the journaldialogs with the celebrations of the centenary of Edinburgh, parting formthe intriguing theme: "Mission in the 21st century in Brazil". After all, howis it that mission takes place among us in personal, church, and communityactivities?Within the Dossier, as common to the journal, the textos are organizedas follows: Bible, Theology / History and Pastoral Care. Other items thatdo not fit within the Dossier, but, do articulate mission, can be found inthe section Declarations and Documents and Book Reviews.The authors of the Dossier have important considerations in buildinga contemporary missiological concept considering Brazilian reality.Anderson de Oliveira, in the Bible-Section, presents a significantexegeses of Matthew 26.6-13. What does it mean when Jesus is quotedwith the words: "For the poor always ye have with you, but me ye havenot always." Is this declaration challenging the gospels

  14. Photometric and clustering properties of hydrodynamical galaxies in a cosmological volume: results at z=0

    CERN Document Server

    Nuza, S E; Saro, A

    2010-01-01

    In this work, we present results for the photometric and clustering properties of galaxies that arise in a LambdaCDM hydrodynamical simulation of the local Universe. The present-day distribution of matter was constructed to match the observed large scale pattern of the IRAS 1.2-Jy galaxy survey. Our simulation follows the formation and evolution of galaxies in a cosmological sphere with a volume of ~130^3 (Mpc/h)^3 including supernova feedback, galactic winds, photoheating due to an uniform meta-galactic background and chemical enrichment of the gas and stellar populations. However, we do not consider AGNs. In the simulation, a total of ~20000 galaxies are formed above the resolution limit, and around 60 haloes are more massive than ~10^14 M_sun. Luminosities of the galaxies are calculated based on a stellar population synthesis model including the attenuation by dust, which is calculated from the cold gas left within the simulated galaxies. Environmental effects like colour bi-modality and differential clust...

  15. Photometric and clustering properties of hydrodynamical galaxies in a cosmological volume: results at z = 0

    Science.gov (United States)

    Nuza, Sebastián E.; Dolag, Klaus; Saro, Alexandro

    2010-09-01

    In this work, we present results for the photometric and clustering properties of galaxies that arise in a Λ cold dark matter hydrodynamical simulation of the local Universe. The present-day distribution of matter was constructed to match the observed large-scale pattern of the IRAS 1.2-Jy galaxy survey. Our simulation follows the formation and evolution of galaxies in a cosmological sphere with a volume of ~1303h-3Mpc3 including supernova feedback, galactic winds, photoheating due to a uniform meta-galactic background and chemical enrichment of the gas and stellar populations. However, we do not consider active galactic nuclei. In the simulation, a total of ~20000 galaxies are formed above the resolution limit, and around 60 haloes are more massive than ~1014Msolar. Luminosities of the galaxies are calculated based on a stellar population synthesis model including the attenuation by dust, which is calculated from the cold gas left within the simulated galaxies. Environmental effects such as colour bimodality and differential clustering power of the hydrodynamical galaxies are qualitatively similar to observed trends. Nevertheless, the overcooling present in the simulations leads to too blue and overluminous brightest cluster galaxies (BCGs). To overcome this, we mimic the late-time suppression of star formation in massive haloes by ignoring recently formed stars with the aid of a simple post-processing recipe. In this way we find luminosity functions, both for field and for group/cluster galaxies, in better agreement with observations. Specifically, the BCGs then follow the observed luminosity-halo mass relation. However, in such a case, the colour bimodality is basically lost, pointing towards a more complex interplay of late suppression of star formation than what is given by the simple scheme adopted.

  16. FY 1995 Scientific and Technical Reports, Articles, Papers, and Presentations, Volume 1

    Science.gov (United States)

    Turner, Joyce E. (Compiler)

    1995-01-01

    This document presents formal NASA technical reports, papers published in technical journals, and presentations by MSFC personnel in FY95. It also includes papers of MSFC contractors. The information in this report may be of value to the scientific and engineering community in determining what information has been published and what is available.

  17. FY 1996 Scientific and Technical Reports, Articles, Papers, and Presentations. Volume 1

    Science.gov (United States)

    Turner-Waits, Joyce E. (Compiler)

    1996-01-01

    This document presents formal NASA technical reports, papers published in technical journals, and presentations by MSFC personnel in FY96. It also includes papers of MSFC contractors. After being announced in STAR, all of the NASA series reports may be obtained from the National Technical Information Service, 5285 Port Royal Road, Springfield, VA 22161. The information in this report may be of value to the scientific and engineering community in determining what information has been published and what is available.

  18. Analysis and presentation of experimental results with examples, problems and programs

    CERN Document Server

    Christodoulides, Costas

    2017-01-01

    This book is intended as a guide to the analysis and presentation of experimental results. It develops various techniques for the numerical processing of experimental data, using basic statistical methods and the theory of errors. After presenting basic theoretical concepts, the book describes the methods by which the results can be presented, both numerically and graphically. The book is divided into three parts, of roughly equal length, addressing the theory, the analysis of data, and the presentation of results. Examples are given and problems are solved using the Excel, Origin, Python and R software packages. In addition, programs in all four languages are made available to readers, allowing them to use them in analyzing and presenting the results of their own experiments. Subjects are treated at a level appropriate for undergraduate students in the natural sciences, but this book should also appeal to anyone whose work involves dealing with experimental results.

  19. Perturbative results for two and three particle threshold energies in finite volume

    CERN Document Server

    Hansen, Maxwell T

    2016-01-01

    We calculate the energy of the state closest to threshold for two and three identical, spinless particles confined to a cubic spatial volume with periodic boundary conditions and with zero total momentum in the finite-volume frame. The calculation is performed in relativistic quantum field theory with particles coupled via a $\\lambda \\phi^4$ interaction, and we work through order $\\lambda^3$. The energy shifts begin at ${\\cal O}(1/L^3)$, and we keep subleading terms proportional to $1/L^4$, $1/L^5$ and $1/L^6$. These terms allow a non-trivial check of the results obtained from quantization conditions that hold for arbitrary interactions, namely that of L\\"uscher for two particles and our recently developed formalism for three particles. We also compare to previously obtained results based on non-relativistic quantum mechanics.

  20. Proceedings of the 2010 AFMS Medical Research Symposium. Volume 5. Nursing Track: Abstracts and Presentations

    Science.gov (United States)

    2011-03-15

    17  Inpatient Glycemic Management Team at Wilford Hall Medical Center ................................................. 21  Diabetes Self...researchers will examine the relationships between home station altitude, history of anemia, recent blood donation, vegetarian diet choice, and...quality care for either hospitalized diabetic or non- diabetic patients. As demonstrated by current research, sustained hyperglycemia results in

  1. Reshaping the laboratory results presentation layer: three interfaces for handheld devices.

    Science.gov (United States)

    Ehrler, Frederic; Brissaud, Marion; Wipfli, Rolf; Lovis, Christian

    2015-01-01

    The interpretation of laboratory results is a critical part of the clinical decision making process. The proper understanding of many clinical conditions depends on the identification of evidences in the laboratory reports. If the classic tabular presentation of laboratory results has demonstrated its efficiency since many years, the increase number of potential results, the increased complexity of cases and the time shortage to analyses cases raise the question of finding more efficient ways of displaying these results to clinicians. The presentation layer becomes even more crucial when it comes to small-sized interactive displays. In this work, we discuss three alternative graphical representations of laboratory results adapted to handheld devices.

  2. An analysis of Chemical Stockpile Emergency Preparedness Program exercise results. Volume 1: The CSEPP Exercise Results Database

    Energy Technology Data Exchange (ETDEWEB)

    Hewett, P.L. Jr.; Mitrani, J.E.; Absil-Mills, M.J.G.; Tallarovic, P.; Molsen, J.; Vercellone, J.; Madore, M.A.

    1998-06-01

    The primary focus of the Chemical Stockpile Emergency Preparedness Program (CSEPP) is to enhance the response capabilities of the eight US Army installations that store chemical weapons agent and of the communities immediately surrounding each Army storage installation. Exercises are a major component of the program and are conducted annually at each of the eight installations. Following each exercise, a report summarizing the results of the exercise is produced. To gain a better perspective on the site-specific and program-wide results of these exercises, the Project Manager for Chemical Stockpile Emergency Preparedness requested that Argonne National Laboratory develop a database containing the results of exercises held through June 1996. This document provides a summary of the process used to develop the CSEPP Exercise Results Database. The database provides CSEPP managers in the Department of the Army and the Federal Emergency Management Agency a method for tracking and analyzing exercise results. The report discusses the collection and coding of exercise data and provides tables to guide coding of future exercise results. An electronic copy of the database (CD-ROM) accompanies the report. This report focuses only on methods used to collect exercise data and develop the database; Volume 2 discusses the analysis of the data collected.

  3. The FODA-TDMA satellite access scheme - Presentation, study of the system, and results

    Science.gov (United States)

    Celandroni, Nedo; Ferro, Erina

    1991-12-01

    A description is given of FODA-TDMA, a satellite access scheme designed for mixed traffic. The study of the system is presented and the choice of some parameters is justified. A simplified analytic solution is found, describing the steady-state behavior of the system. Some results of the simulation tests for an already existing hardware environment are also presented for the channel speeds of 2 and 8 Mb/s, considering both the stationary and the transient cases. The results of the experimentation at 2 Mb/s on the satellite Eutelsat-F2 are also presented and compared with the results of the simulation.

  4. Proceedings of the 2010 AFMS Medical Research Symposium. Volume 1. Plenary Sessions, Presentation and Poster Abstracts

    Science.gov (United States)

    2011-03-15

    0157:H7 (EHEC), Shigella, Salmonella, and Campylobacter , and evaluated using both the HMLK and the JBAIDS species- specific assays. RESULTS: EHEC...detected by HMLK but detected by JBAIDS. Campylobacter was not detected at high or low concentrations by the HMLK but was successfully detected by...cMAbs stably produced by the DHFR double mutant Chinese hamster ovarian (CHO)- DG44 cells were affinity-purified. By ELISA and Western blot analysis

  5. Present Concepts in Internal Medicine. Volume 13, Number 1. Endocrinology Research Symposium,

    Science.gov (United States)

    1980-01-01

    have caused overt hyperthyroidism , 14 most have been reported in hypothyroid patients. 15 Presumably long-standing primary hypothyroidism results in...experience (in the absence of conditions causing false positive responses) the presence of elevated urine free cortisol (> 100 Vg/24 h) and lack of...corticoids with normal or subnormal levels of urine 17- ketosteroids. Since adrenal tumors causing Cushing’s syndrome are usually greater than 2 cm in

  6. Presentation of the 1998 financial results of the Framatome group; Presentation des resultats financiers 1998 du groupe Framatome

    Energy Technology Data Exchange (ETDEWEB)

    Vignon, D

    1999-04-08

    This document makes a statement of the activity of the Framatome group during the year 1998. The activities of the group are shared into two main sectors of comparable size: the energy sector (nuclear fuels, nuclear realizations, nuclear services and industrial equipments) and the connectors engineering sector (electronics, electricity, automotive industry, interconnections and microelectronics). The financial results show an important growth of the connectors engineering sector while the energy sector remained satisfactory. Results are detailed by sector and activity: energy (realizations and nuclear equipments, nuclear services, nuclear fuels and industrial equipments), connectors engineering, and research and development activity of the group. (J.S.)

  7. Searches for new physics: Les Houches recommendations for the presentation of LHC results

    Energy Technology Data Exchange (ETDEWEB)

    Kraml, S.; /LPSC, Grenoble; Allanach, B.C.; /Cambridge U., DAMTP; Mangano, M.; /CERN; Prosper, H.B.; /Florida State U.; Sekmen, S.; /CERN /Florida State U.; Balazs, C.; /Monash U.; Barr, A.; /Oxford U.; Bechtle, P.; /Bonn U.; Belanger, G.; /Annecy, LAPTH; Belyaev, A.; /Rutherford /Southampton U.; Benslama, K.; /Regina U.; Campanelli, M.; /University Coll. London; Cranmer, K.; /New York U., CCPP; De Roeck, A.; /CERN; Dolan, M.J.; /Durham U., IPPP; Eifert, T.; /SLAC; Ellis, J.R.; /King' s Coll. London /CERN; Felcini, M.; /Cantabria U., Santander; Fuks, B.; /Strasbourg, IPHC /Strasbourg, IReS; Guadagnoli, D.; /Orsay, LPT /Annecy, LAPTH; Gunion, J.F.; /UC, Davis /Cantabria U., Santander /SLAC /NICPB, Tallinn /Aachen, Tech. Hochsch. /Fermilab /Clermont-Ferrand U. /CERN /Clermont-Ferrand U. /Northern Illinois U. /Santa Barbara, KITP /SLAC /Dresden, Tech. U. /Gent U. /DESY

    2012-04-17

    We present a set of recommendations for the presentation of LHC results on searches for new physics, which are aimed at providing a more efficient flow of scientific information between the experimental collaborations and the rest of the high energy physics community, and at facilitating the interpretation of the results in a wide class of models. Implementing these recommendations would aid the full exploitation of the physics potential of the LHC.

  8. Initial experience with a group presentation of study results to research participants

    Directory of Open Access Journals (Sweden)

    Bent Stephen

    2008-03-01

    Full Text Available Abstract Background Despite ethical imperatives, informing research participants about the results of the studies in which they take part is not often performed. This is due, in part, to the costs and burdens of communicating with each participant after publication of the results. Methods Following the closeout and publication of a randomized clinical trial of saw palmetto for treatment of symptoms of benign prostatic hyperplasia, patients were invited back to the research center to participate in a group presentation of the study results. Results Approximately 10% of participants attended one of two presentation sessions. Reaction to the experience of the group presentation was very positive among the attendees. Conclusion A group presentation to research participants is an efficient method of communicating study results to those who desire to be informed and was highly valued by those who attended. Prospectively planning for such presentations and greater scheduling flexibility may result in higher attendance rates. Trial Registration Number Clinicaltrials.gov #NCT00037154

  9. Fast ion collective Thomson scattering - present results and plans for ITER

    DEFF Research Database (Denmark)

    Korsholm, Søren Bang; Bindslev, Henrik; Furtula, Vedran;

    scattering (CTS) provides the possibility of revealing the velocity distribution of the confined fast ions along a given direction – resolved both in time and space. Recently, the ITER baseline design has been expanded to include a fast ion CTS diagnostic. The design of this diagnostic was provided...... and results, and present the expectations for the ITER CTS diagnostic....

  10. Analysis Results for ARRA Projects: Enabling Fuel Cell Market Transformation (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, J.; Wipke, K.; Sprik, S.; Ramsden, T.; Ainscough, C.; Saur, G.

    2012-06-01

    This presentation discusses analysis results for American Recovery and Reinvestment Act early market fuel cell deployments and describes the objective of the project and its relevance to the Department of Energy Hydrogen and Fuel Cells Program; NREL's analysis approach; technical accomplishments including publication of a fourth set of composite data products; and collaborations and future work.

  11. Presenting results as dynamically generated co-authorship subgraphs in semantic digital library collections

    Directory of Open Access Journals (Sweden)

    James Powell

    2012-02-01

    Full Text Available Semantic web representations of data are by definition graphs, and these graphs can be explored using concepts from graph theory. This paper demonstrates how semantically mapped bibliographic metadata, combined with a lightweight software architecture and Web-based graph visualization tools, can be used to generate dynamic authorship graphs in response to typical user queries, as an alternative to more common text-based results presentations. It also shows how centrality measures and path analysis techniques from social network analysis can be used to enhance the visualization of query results. The resulting graphs require modestly more cognitive engagement from the user but offer insights not available from text.

  12. Association of intradialytic hypotension and convective volume in hemodiafiltration: results from a retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Mora-Bravo Franklin G

    2012-09-01

    Full Text Available Abstract Background Hemodiafiltration (HDF, as a convective blood purification technique, has been associated with favorable outcomes improved phosphate control, removal of middle-molecules such as Beta2-microglobulin and the occurrence of intradialytic hypotension (IDH as compared to diffusive techniques. The aim of this retrospective cohort study in dialysis patients receiving HDF in one urban dialysis facility in Mexico City was to investigate the occurrence of IDH during HDF treatments with varying convective volume prescriptions. Methods Subjects were stratified into equal groups of percentiles of convective volume prescription: Group 1 of 0 to 7.53 liters, group 2 of 7.54 to 14.8 liters, group 3 of 14.9 to 16.96 liters, group 4 of 16.97 to 18.9 liters, group 5 of 21 to 19.9 liters and group 6 of 21.1 to 30 liters. Logistic Regression with and without adjustment for confounding factors was used to evaluate factors associated with the occurrence of IDH. Results 2276 treatments of 154 patients were analyzed. IDH occurred during 239 HDF treatments (10.5% of all treatments. Group 1 showed 31 treatments (8.2% with IDH whereas group 6 showed IDH in only 15 sessions (4% of all treatments. Odds Ratio of IDH for Group 6 was 0.47 (95% CI 0.25 to 0.88 as compared to Group 1 after adjustment. Conclusions In summary the data of this retrospective cohort study shows an inverse correlation between the occurrence of IDH and convective volume prescription. Further research in prospective settings is needed to confirm these findings.

  13. Desmoplastic small round cell tumor: Extra abdominal and abdominal presentations and the results of treatment

    Directory of Open Access Journals (Sweden)

    Biswas G

    2005-01-01

    Full Text Available BACKGROUND: Desmoplastic small round cell tumor (DSRCT is a rare malignant neoplasm of adolescent males. Current multimodality treatment prolongs life and rarely achieves cure. Aim: To review the presenting features, histopathology and outcome of 18 patients with DSRCT treated at a single institution. Setting and Design: This is a retrospective observational study of patients with DSRCT who presented at the Tata Memorial Hospital between January 1994 to January 2005. Materials and Methods: Eighteen patients of DSRCT seen during this period were evaluated for their clinical presentation, response to chemotherapy and other multimodality treatment and overall survival. The cohort of 18 patients included 11 males (61% and 7 females (39% with a mean age of 16 years (Range 1½ - 30 years. Majority (83% presented with abdomino-pelvic disease. The others, involving chest wall and extremities. There were 6 patients (33% with metastatic disease at presentation. Results:The treatment primarily included a multimodality approach using a combination of multiagent chemotherapy with adjuvant surgery and radiotherapy as applicable. A response rate of 39% (CR-1, PR-6, with chemotherapy was observed. The overall response rate after multimodality treatment was 39% (CR-5, PR-2. The overall survival was poor except in patients who had complete excision of the tumor. Conclusion: Abdomino-pelvic site was the commonest presentation, the disease can occur at other non-serosal surfaces also. Despite aggressive treatment the outcome was poor. However, complete surgical excision seems to provide a better survival.

  14. Association between tuberculin skin test result and clinical presentation of tuberculosis disease.

    Science.gov (United States)

    Auld, Sara C; Click, Eleanor S; Heilig, Charles M; Miramontes, Roque; Cain, Kevin P; Bisson, Gregory P; Mac Kenzie, William R

    2013-10-04

    The tuberculin skin test (TST) is used to test for latent tuberculosis (TB) infection and support the diagnosis of active TB. However, little is known about the relationship between the TST result and the clinical presentation of TB disease. We analyzed US TB surveillance data, 1993-2010, and used multinomial logistic regression to calculate the association between TST result (0-4 mm [negative], 5-9 mm, 10-14 mm, and  ≥ 15 mm) and clinical presentation of disease (miliary, combined pulmonary and extrapulmonary, extrapulmonary only, non-cavitary pulmonary, and cavitary pulmonary). For persons with pulmonary disease, multivariate logistic regression was used to calculate the odds of having acid-fast bacilli (AFB) positive sputum. There were 64,238 persons with culture-confirmed TB included in the analysis, which was stratified by HIV status and birthplace (US- vs. foreign-born). Persons with a TST ≥ 15 mm were less likely to have miliary or combined pulmonary and extrapulmonary disease, but more likely to have cavitary pulmonary disease than non-cavitary pulmonary disease. Persons with non-cavitary pulmonary disease with a negative TST were significantly more likely to have AFB positive sputum. Clinical presentation of TB disease differed according to TST result and persons with a negative TST were more likely to have disseminated disease (i.e., miliary or combined pulmonary and extrapulmonary). Further study of the TST result may improve our understanding of the host-pathogen relationship in TB disease.

  15. Seismic hazard analysis application of methodology, results, and sensitivity studies. Volume 4

    Energy Technology Data Exchange (ETDEWEB)

    Bernreuter, D. L

    1981-08-08

    As part of the Site Specific Spectra Project, this report seeks to identify the sources of and minimize uncertainty in estimates of seismic hazards in the Eastern United States. Findings are being used by the Nuclear Regulatory Commission to develop a synthesis among various methods that can be used in evaluating seismic hazard at the various plants in the Eastern United States. In this volume, one of a five-volume series, we discuss the application of the probabilistic approach using expert opinion. The seismic hazard is developed at nine sites in the Central and Northeastern United States, and both individual experts' and synthesis results are obtained. We also discuss and evaluate the ground motion models used to develop the seismic hazard at the various sites, analyzing extensive sensitivity studies to determine the important parameters and the significance of uncertainty in them. Comparisons are made between probabilistic and real spectral for a number of Eastern earthquakes. The uncertainty in the real spectra is examined as a function of the key earthquake source parameters. In our opinion, the single most important conclusion of this study is that the use of expert opinion to supplement the sparse data available on Eastern United States earthquakes is a viable approach for determining estimted seismic hazard in this region of the country. 29 refs., 15 tabs.

  16. Some GCM simulation results on present and possible future climate in northern Europe

    Energy Technology Data Exchange (ETDEWEB)

    Raeisaenen, J. [Helsinki Univ. (Finland). Dept. of Meteorology

    1995-12-31

    The Intergovernmental Panel on Climate Change initiated in 1993 a project entitled `Evaluation of Regional Climate Simulations`. The two basic aims of this project were to assess the skill of current general circulation models (GCMs) in simulating present climate at a regional level and to intercompare the regional response of various GCMs to increased greenhouse gas concentrations. The public data base established for the comparison included simulation results from several modelling centres, but most of the data were available in the form of time-averaged seasonal means only, and important quantities like precipitation were totally lacking in many cases. This presentation summarizes the intercomparison results for surface air temperature and sea level pressure in northern Europe. The quality of the control simulations and the response of the models to increased CO{sub 2} are addressed in both winter (December-February) and summer (June-August)

  17. Presentations from the Aeroelastic Workshop - latest results from AeroOpt

    Energy Technology Data Exchange (ETDEWEB)

    Hartvig Hansen, M. (ed.)

    2011-10-15

    This report contains the slides of the presentations at the Aeroelastic Workshop held at Risoe-DTU for the wind energy industry in Denmark on October 27, 2011. The scientific part of the agenda at this workshop was 1) Detailed and reduced models of dynamic mooring system (Anders M. Hansen). 2) Bend-twist coupling investigation in HAWC2 (Taeseong Kim). 3) Q3UIC - A new aerodynamic airfoil tool including rotational effects (Nestor R. Garcia). 4) Influence of up-scaling on loads, control and aerodynamic modeling (Helge Aa. Madsen). 5) Aerodynamic damping of lateral tower vibrations (Bjarne S. Kallesoee). 6) Open- and closed-loop aeroservoelastic analysis with HAWCStab2 (Morten H. Hansen). 7) Design and test of a thick, flatback, high-lift multielement airfoil (Frederik Zahle). The presented results are mainly obtained in the EUDP project ''Aeroelastic Optimization of MW Wind Turbines (AeroOpt)''. (Author)

  18. Scientific presentation of project results: Role playing in a course for nonscientists

    Science.gov (United States)

    Jewett, John W.

    1981-06-01

    One of the goals of a science course for nonscientists is to introduce the student to the thought processes and experiences of being a scientist. This article discusses a role-playing technique used in a physics of music course that addresses this goal. The students choose a research project to work on, and present their results as a journal article or an oral presentation at a scientific ''meeting.'' The journal articles are refereed and those accepted, along with a program of the meeting, are formed into a journal which is distributed to all the students. Student response has been positive, both in terms of enjoyment of the project and of improvement in writing skills.

  19. Large volume unresectable locally advanced non-small cell lung cancer: acute toxicity and initial outcome results with rapid arc

    Directory of Open Access Journals (Sweden)

    Fogliata Antonella

    2010-10-01

    Full Text Available Abstract Background To report acute toxicity, initial outcome results and planning therapeutic parameters in radiation treatment of advanced lung cancer (stage III with volumetric modulated arcs using RapidArc (RA. Methods Twenty-four consecutive patients were treated with RA. All showed locally advanced non-small cell lung cancer with stage IIIA-IIIB and with large volumes (GTV:299 ± 175 cm3, PTV:818 ± 206 cm3. Dose prescription was 66Gy in 33 fractions to mean PTV. Delivery was performed with two partial arcs with a 6 MV photon beam. Results From a dosimetric point of view, RA allowed us to respect most planning objectives on target volumes and organs at risk. In particular: for GTV D1% = 105.6 ± 1.7%, D99% = 96.7 ± 1.8%, D5%-D95% = 6.3 ± 1.4%; contra-lateral lung mean dose resulted in 13.7 ± 3.9Gy, for spinal cord D1% = 39.5 ± 4.0Gy, for heart V45Gy = 9.0 ± 7.0Gy, for esophagus D1% = 67.4 ± 2.2Gy. Delivery time was 133 ± 7s. At three months partial remission > 50% was observed in 56% of patients. Acute toxicities at 3 months showed 91% with grade 1 and 9% with grade 2 esophageal toxicity; 18% presented grade 1 and 9% with grade 2 pneumonia; no grade 3 acute toxicity was observed. The short follow-up does not allow assessment of local control and progression free survival. Conclusions RA proved to be a safe and advantageous treatment modality for NSCLC with large volumes. Long term observation of patients is needed to assess outcome and late toxicity.

  20. [DESCRIPTION AND PRESENTATION OF THE RESULTS OF ELECTROENCEPHALOGRAM PROCESSING USING AN INFORMATION MODEL].

    Science.gov (United States)

    Myznikov, I L; Nabokov, N L; Rogovanov, D Yu; Khankevich, Yu R

    2016-01-01

    The paper proposes to apply the informational modeling of correlation matrix developed by I.L. Myznikov in early 1990s in neurophysiological investigations, such as electroencephalogram recording and analysis, coherence description of signals from electrodes on the head surface. The authors demonstrate information models built using the data from studies of inert gas inhalation by healthy human subjects. In the opinion of the authors, information models provide an opportunity to describe physiological processes with a high level of generalization. The procedure of presenting the EEG results holds great promise for the broad application.

  1. Presentation, clinical features, and results of intervention in upper extremity fibromuscular dysplasia.

    Science.gov (United States)

    Nguyen, Nancy; Sharma, Aditya; West, Jonathan K; Serhal, Maya; Brinza, Ellen; Gornik, Heather L; Kim, Esther S H

    2017-08-01

    medically (33.3%), surgical bypass in 2 limbs initially treated with angioplasty, surgical bypass in 1 limb initially treated with medical therapy, and sympathectomy in 1 limb (16.7%) initially treated with angioplasty. Both surgical bypass and angioplasty as secondary interventions resulted in complete symptom relief. Presenting symptoms for patients with UE FMD vary in severity from asymptomatic disease to digital ischemia. More than half of symptomatic limbs eventually require at least one invasive intervention for complete relief of symptoms. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  2. Channeling, volume reflection and gamma emission using 14GeV electrons in bent silicon crystals - Oral presentation

    Energy Technology Data Exchange (ETDEWEB)

    Benson, Brandon [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-23

    High energy electrons can be deflected with very tight bending radius using a bent silicon crystal. This produces gamma radiation. As these crystals can be thin, a series of bent silicon crystals with alternating direction has the potential to produce coherent gamma radiation with reasonable energy of the driving electron beam. Such an electron crystal undulator offers the prospect for higher energy radiation at lower cost than current methods. Permanent magnetic undulators like LCLS at SLAC National Accelerator Laboratory are expensive and very large (about 100 m in case of the LCLS undulator). Silicon crystals are inexpensive and compact when compared to the large magnetic undulators. Additionally, such a high energy coherent light source could be used for probing through materials currently impenetrable by x-rays. In this work we present the experimental data and analysis of experiment T523 conducted at SLAC National Accelerator Laboratory. We collected the spectrum of gamma ray emission from 14 GeV electrons on a bent silicon crystal counting single photons. We also investigated the dynamics of electron motion in the crystal i.e. processes of channeling and volume reflection at 14 GeV, extending and building off previous work. Our single photon spectrum for the amorphous crystal orientation is consistent with bremsstrahlung radiation and the volume reflection crystal orientation shows a trend consistent with synchrotron radiation at a critical energy of 740 MeV. We observe that in these two cases the data are consistent, but we make no further claims because of statistical limitations. We also extended the known energy range of electron crystal dechanneling length and channeling efficiency to 14 GeV.

  3. An unusual presentation of a massive pulmonary embolism with misleading investigation results treated with tenecteplase.

    Science.gov (United States)

    Migneault, David; Levine, Zachary; de Champlain, François

    2015-01-01

    Background. There is no foolproof strategy to identify a pulmonary embolism (PE) in the emergency department, and atypical presentations are common. Negative test results may mislead physicians away from the diagnosis of PE. Objectives. The current report aims to raise awareness of an unusual presentation of massive PE and its diagnosis and management, in the face of limited evidence in the scientific literature. Case Reports. We report the case of a patient with a negative D-Dimer and a negative Computed Tomography contrast angiography of the chest who was diagnosed twenty-seven hours later with a massive PE, as suggested by a bedside echocardiography. The patient was successfully treated with tenecteplase (TNK). Conclusions/Summary. Pulmonary embolism frequently presents atypically and is often a diagnostic challenge. There is limited literature about the treatment of massive PE. Further research on bedside echocardiography for diagnosing PE in unstable patients is warranted. In addition, further study into new thrombolytic agents like tenecteplase in the context of massive and submassive PE is warranted.

  4. An Unusual Presentation of a Massive Pulmonary Embolism with Misleading Investigation Results Treated with Tenecteplase

    Directory of Open Access Journals (Sweden)

    David Migneault

    2015-01-01

    Full Text Available Background. There is no foolproof strategy to identify a pulmonary embolism (PE in the emergency department, and atypical presentations are common. Negative test results may mislead physicians away from the diagnosis of PE. Objectives. The current report aims to raise awareness of an unusual presentation of massive PE and its diagnosis and management, in the face of limited evidence in the scientific literature. Case Reports. We report the case of a patient with a negative D-Dimer and a negative Computed Tomography contrast angiography of the chest who was diagnosed twenty-seven hours later with a massive PE, as suggested by a bedside echocardiography. The patient was successfully treated with tenecteplase (TNK. Conclusions/Summary. Pulmonary embolism frequently presents atypically and is often a diagnostic challenge. There is limited literature about the treatment of massive PE. Further research on bedside echocardiography for diagnosing PE in unstable patients is warranted. In addition, further study into new thrombolytic agents like tenecteplase in the context of massive and submassive PE is warranted.

  5. Delayed Presentation of Traumatic Diaphragmatic Hernia: The Evaluation of Surgical Treatment Results

    Directory of Open Access Journals (Sweden)

    Ali Sadrizadeh

    2015-06-01

    Full Text Available Introduction: Diaphragmatic hernia could be caused by congenital disorders, blunt trauma or penetrating injuries. The diagnosis of traumatic diaphragmatic hernia is normally neglected during the first presentation leading to late complications and considerably increased mortality and morbidity among the patients. Materials and Methods: In this retrospective, descriptive study, we reviewed the medical records of patients presented with traumatic diaphragmatic hernia who had undergone surgical operations between 1982-2015 in Ghaem Hospital and Omid Hospital affiliated to Mashhad University of Medical Sciences, Iran. The studied variables included age, gender, clinical symptoms, location of hernia, involved organs, type of imaging modalities, surgical techniques, length of hospital stay, mortality rate and surgical complications. Results: In this study, 38 patients were diagnosed with traumatic diaphragmatic hernia consisting of 28 men and 10 women. In total, 79% and 21% of the patients suffered from penetrating trauma and blunt trauma, respectively. In addition, left-sided, right-sided and bilateral hernias were present in 33%, 4% and 1% of the patients, respectively. The most frequently herniated organ was the stomach, and the most common clinical symptoms were abdominal pain (84% and dyspnea (53%. Initially, chest radiographs were performed on all the patients, and thoracotomy was performed to repair diaphragmatic tears in all the cases (100%. In this study, 3 patients had previously undergone Hartmann’s operation for gangrenous herniated colon, and devolvulation of gastric volvulus had also been performed on 3 patients. The main post-operative complications were reported to be pneumonia and respiratory insufficiency (2 cases, and the mean length of hospital stay was 6 days (5-8 days which was longer (1-2 months in patients with gangrenous bowel (3 patients. Furthermore, no mortality was reported during the course of hospitalization in these

  6. INPRES (intraoperative presentation of surgical planning and simulation results): augmented reality for craniofacial surgery

    Science.gov (United States)

    Salb, Tobias; Brief, Jakob; Welzel, Thomas; Giesler, Bjoern; Hassfeld, Steffan; Muehling, Joachim; Dillmann, Ruediger

    2003-05-01

    In this paper we present recent developments and pre-clinical validation results of our approach for augmented reality (AR, for short) in craniofacial surgery. A commercial Sony Glasstron display is used for optical see-through overlay of surgical planning and simulation results with a patient inside the operation room (OR). For the tracking of the glasses, of the patient and of various medical instruments an NDI Polaris system is used as standard solution. A complementary inside-out navigation approach has been realized with a panoramic camera. This device is mounted on the head of the surgeon for tracking of fiducials placed on the walls of the OR. Further tasks described include the calibration of the head-mounted display (HMD), the registration of virtual objects with the real world and the detection of occlusions in the object overlay with help of two miniature CCD cameras. The evaluation of our work took place in the laboratory environment and showed promising results. Future work will concentrate on the optimization of the technical features of the prototype and on the development of a system for everyday clinical use.

  7. Effects of elevated vacuum on in-socket residual limb fluid volume: Case study results using bioimpedance analysis

    Directory of Open Access Journals (Sweden)

    Joan E. Sanders, PhD

    2011-12-01

    Full Text Available Bioimpedance analysis was used to measure the residual limb fluid volume of seven transtibial amputee subjects using elevated vacuum sockets and nonelevated vacuum sockets. Fluid volume changes were assessed during sessions with the subjects sitting, standing, and walking. In general, fluid volume losses during 3 or 5 min walks and losses over the course of the 30 min test session were less for elevated vacuum than for suction. Numerous variables, including the time of day that data were collected, soft tissue consistency, socket-to-limb size and shape differences, and subject health, may have affected the results and had an equivalent or greater effect on limb fluid volume compared with elevated vacuum. Researchers should well consider these variables in the study design of future investigations on the effects of elevated vacuum on residual limb volume.

  8. Effects of elevated vacuum on in-socket residual limb fluid volume: Case study results using bioimpedance analysis

    Science.gov (United States)

    Sanders, JE; Harrison, DS; Myers, TR; Allyn, KJ

    2015-01-01

    Bioimpedance analysis was used to measure residual limb fluid volume on seven trans-tibial amputee subjects using elevated vacuum sockets and non-elevated vacuum sockets. Fluid volume changes were assessed during sessions with the subjects sitting, standing, and walking. In general, fluid volume losses during 3 or 5 min walks and losses over the course of the 30-min test session were less for elevated vacuum than for suction. A number of variables including the time of day data were collected, soft tissue consistency, socket-to-limb size differences and shape differences, and subject health may have affected the results and had an equivalent or greater impact on limb fluid volume compared with elevated vacuum. Researchers should well consider these variables in study design of future investigations on the effects of elevated vacuum on residual limb volume. PMID:22234667

  9. The LHCf experiment: present status and physics results arXiv

    CERN Document Server

    Berti, Eugenio

    The main aim of the LHCf experiment is to provide precise measurements of the production spectra relative to neutral particle produced by high energy proton-ion collisions in the very forward region. This information is necessary in order to test and tune hadronic interaction models used by ground-based cosmic rays experiments. In order to reach this goal, LHCf makes use of two small sampling calorimeters installed in the LHC tunnel at $\\pm 140$ m from IP1, able to detect neutral particles having pseudo-rapidity $\\eta > 8.4$. In this paper we will present the current status of the LHCf experiment, regarding in particular the first analysis results from data taking relative to p-p collisions at $\\sqrt{s} = $ 13 TeV.

  10. S-2 stage 1/25 scale model base region thermal environment test. Volume 1: Test results, comparison with theory and flight data

    Science.gov (United States)

    Sadunas, J. A.; French, E. P.; Sexton, H.

    1973-01-01

    A 1/25 scale model S-2 stage base region thermal environment test is presented. Analytical results are included which reflect the effect of engine operating conditions, model scale, turbo-pump exhaust gas injection on base region thermal environment. Comparisons are made between full scale flight data, model test data, and analytical results. The report is prepared in two volumes. The description of analytical predictions and comparisons with flight data are presented. Tabulation of the test data is provided.

  11. The Economic Contribution of Canada's Colleges and Institutes. An Analysis of Investment Effectiveness and Economic Growth. Volume 2: Detailed Results by Gender and Entry Level of Education

    Science.gov (United States)

    Robison, M. Henry; Christophersen, Kjell A.

    2008-01-01

    The purpose of this volume is to present the results of the economic impact analysis in detail by gender and entry level of education. On the data entry side, gender and entry level of education are important variables that help characterize the student body profile. This profile data links to national statistical databases which are already…

  12. The new Inventory of Italian Glaciers: Present knowledge, applied methods and preliminary results

    Science.gov (United States)

    Smiraglia, Claudio; Diolaiuti, Guglielmina; D'Agata, Carlo; Maragno, Davide; Baroni, Carlo; Mortara, Gianni; Perotti, Luigi; Bondesan, Aldino; Salvatore, Cristina; Vagliasindi, Marco; Vuillermoz, Elisa

    2013-04-01

    A new Glacier Inventory is an indispensable requirement in Italy due to the importance of evaluating the present glacier coverage and the recent changes driven by climate. Furthermore Alpine glaciers represent a not negligible water and touristic resource then to manage and promote them is needed to know their distribution, size and features. The first Italian Glacier Inventory dates back to 1959-1962. It was compiled by the Italian Glaciological Committee (CGI) in cooperation with the National Research Council (CNR); this first inventory was mainly based on field data coupled with photographs (acquired on the field) and high resolution maps. The Italian glaciation resulted to be spread into 754 ice bodies which altogether were covering 525 km2. Moreover in the Eighties a new inventory was compiled to insert Italian data into the World Glacier Inventory (WGI); aerial photos taken at the end of the Seventies (and in some cases affected by a high and not negligible snow coverage) were used as the main source of data. No other national inventory were compiled after that period. Nevertheless during the last decade the largest part of the Italian Alpine regions have produced regional and local glacier inventories which in several cases are also available and queried through web sites and web GIS application. The actual need is now to obtain a complete, homogeneous and contemporary picture of the Italian Glaciation which encompasses the already available regional and local data and all the new updated information coming from new sources of data (e.g.: orthophotos, satellite imagines, etc..). The challenge was accepted by the University of Milan, the EvK2CNR Committee and the Italian Glaciological Committee who, with the sponsorship of Levissima Spa, are presently working to compile the new updated Italian Glacier Inventory. The first project step is to produce a unique homogeneous glacier database including glacier boundary and surface area and the main fundamental

  13. Investigating the Present Day Cosmic Dust Flux at the Earth's Surface: Initial Results from the Kwajalein Micrometeorite Collection

    Science.gov (United States)

    Wozniakiewicz, P. J.; Bradley, J. P.; Price, M. C.; Zolensky, M. E.; Ishii, H. A.; Brownlee, D. E.; Russell, S. S.

    2014-01-01

    Examination of impact craters on the Long Duration Exposure Facility satellite indicate a present day micrometeoroid flux of approx. 30,000 tonnes [1 after 2]. But what portion of this material arrives at the Earth's surface as micrometeorites? Studies of available micrometeorite collections from deep sea sediments [e.g. 3], Greenland blue ice [e.g. 4] and the South Pole water well [e.g. 1] may be complicated by terrestrial weathering and, in some cases, collection bias (magnetic separation for deep sea sediments) and poorly constrained ages. We have recently set up a micrometeorite collection station on Kwajalein Island in the Republic of the Marshall Islands in the Pacific Ocean, using high volume air samplers to collect particles directly from the atmosphere. By collecting in this way, the terrestrial age of the particles is known, the weathering they experience is minimal, and we are able to constrain particle arrival times. Collecting at this location also exploits the considerably reduced anthropogenic background [5]. Method: High volume air samplers were installed on top of the two-story airport building on Kwajalein. These were fitted with polycarbonate membrane filters with 5µm diameter perforations. The flow rates were set to 0.5m3/min, and filters were changed once a week. After collection, filters were washed to remove salt and concentrate particles [see 5] in preparation for analysis by SEM. Results and Discussion: A selection of filters have been prepared and surveyed. Due to their ease of identification our initial investigations have focused on particles resembling cosmic spherules. The spheres can be divided into three main groups: 1. Silicate spherules rich in Al, Ca, K and Na (to varying degrees), 2. Silicate spherules rich in Mg and Fe and 3. Fe-rich spherules. Group 1 spherules are often vesiculated and can occur as aggregates. They are similar in appearance and composition to volcanic microspheres [e.g. 6] and are thus likely terrestrial in

  14. Semantic Web Services Challenge, Results from the First Year. Series: Semantic Web And Beyond, Volume 8.

    Science.gov (United States)

    Petrie, C.; Margaria, T.; Lausen, H.; Zaremba, M.

    Explores trade-offs among existing approaches. Reveals strengths and weaknesses of proposed approaches, as well as which aspects of the problem are not yet covered. Introduces software engineering approach to evaluating semantic web services. Service-Oriented Computing is one of the most promising software engineering trends because of the potential to reduce the programming effort for future distributed industrial systems. However, only a small part of this potential rests on the standardization of tools offered by the web services stack. The larger part of this potential rests upon the development of sufficient semantics to automate service orchestration. Currently there are many different approaches to semantic web service descriptions and many frameworks built around them. A common understanding, evaluation scheme, and test bed to compare and classify these frameworks in terms of their capabilities and shortcomings, is necessary to make progress in developing the full potential of Service-Oriented Computing. The Semantic Web Services Challenge is an open source initiative that provides a public evaluation and certification of multiple frameworks on common industrially-relevant problem sets. This edited volume reports on the first results in developing common understanding of the various technologies intended to facilitate the automation of mediation, choreography and discovery for Web Services using semantic annotations. Semantic Web Services Challenge: Results from the First Year is designed for a professional audience composed of practitioners and researchers in industry. Professionals can use this book to evaluate SWS technology for their potential practical use. The book is also suitable for advanced-level students in computer science.

  15. Comparative ranking of 0. 1 to 10 MW(e) solar thermal electric power systems. Volume I. Summary of results. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, J.P.; Brown, K.C.; Finegold, J.G.; Gresham, J.B.; Herlevich, F.A.; Kowalik, J.S.; Kriz, T.A.

    1980-08-01

    This report is part of a two-volume set summarizing the results of a comparative ranking of generic solar thermal concepts designed specifically for electric power generation. The original objective of the study was to project the mid-1990 cost and performance of selected generic solar thermal electric power systems for utility applications and to rank these systems by criteria that reflect their future commercial acceptance. This study considered plants with rated capacities of 1 to 10 MW(e), operating over a range of capacity factors from the no-storage case to 0.7 and above. Later, the study was extended to include systems with capacities from 0.1 to 1 MW(e), a range that is attractive to industrial and other non-utility applications. This volume summarizes the results for the full range of capacities from 0.1 to 10 MW(e). Volume II presents data on performance and cost and ranking methodology.

  16. MR coronary angiography with breath-hold targeted volumes: preliminary clinical results

    NARCIS (Netherlands)

    R.J.M. van Geuns (Robert Jan); P.A. Wielopolski (Piotr); H.G. de Bruin (Hein); B.J.W.M. Rensing (Benno); M. Hulshoff (Maarten); P.M.A. van Ooijen (Peter); P.J. de Feyter (Pim); M. Oudkerk (Matthijs)

    2000-01-01

    textabstractPURPOSE: To assess the clinical value of a magnetic resonance (MR) coronary angiography strategy involving a small targeted volume to image one coronary segment in a single breath hold for the detection of greater than 50% stenosis. MATERIALS AND METHODS:

  17. MR coronary angiography with breath-hold targeted volumes : Preliminary clinical results

    NARCIS (Netherlands)

    van Geuns, R J; Wielopolski, P A; de Bruin, Hein G.; Rensing, B J; Hulshoff, Marc; van Ooijen, P M; de Feyter, P J; Oudkerk, M

    2000-01-01

    PURPOSE: To assess the clinical value of a magnetic resonance (MR) coronary angiography strategy involving a small targeted volume to image one coronary segment in a single breath hold for the detection of greater than 50% stenosis. MATERIALS AND METHODS: Thirty-eight patients referred for elective

  18. Total energy cycle assessment of electric and conventional vehicles: an energy and environmental analysis. Volume 3: appendix E to technical report, comprehensive EVTECA results tables

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This report compares the energy use, oil use and emissions of electric vehicles (EVs) with those of conventional, gasoline-powered vehicles (CVs) over the total life cycle of the vehicles. The various stages included in the vehicles` life cycles include vehicle manufacture, fuel production, and vehicle operation. Disposal is not included. An inventory of the air emissions associated with each stage of the life cycle is estimated. Water pollutants and solid wastes are reported for individual processes, but no comprehensive inventory is developed. Volume III presents the results of the total energy cycle model runs, which are summarized in Volume I.

  19. Pacific Northwest residential energy survey. Volume 3. Question-by-question results

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-07-01

    Tabulations are presented of responses to approximately 105 questions. Results are tabulated by 9 geographic regions: the four states of Idaho, Montana, Oregon, and Washington; four climate zones in the region; and a weighted Pacific Northwest total. A description of the tabulated data is given in the Introduction. Tabulated data deal with questions on dwelling characteristics; heating and air-conditioning systems; water heating; appliances; demographic and swelling characteristics; and insulation.

  20. Uniform presentation of process evaluation results facilitates the evaluation of complex interventions: development of a graph

    NARCIS (Netherlands)

    Bakker, F.C.; Persoon, A.; Schoon, Y.; Olde Rikkert, M.G.M.

    2015-01-01

    RATIONALE, AIMS AND OBJECTIVES: Process evaluation is a highly essential element for the increasing number of studies regarding multi-component interventions. Yet, researchers are challenged to collect and present appropriate process outcomes in such way that it is easy and valuable to be used by ot

  1. Prolactinomas may have unusual presentations resulting from massive extrasellar tumor extension

    Directory of Open Access Journals (Sweden)

    Marise Ribeiro de Sousa Berriel

    2016-07-01

    Full Text Available ABSTRACT The purpose of this case series is to report eight patients with giant prolactinomas emphasizing presentations and a treatment complication. The study group included six men and two women. The median age was 29 years (18–54 years; median serum prolactin level was 4,562 ng/ml (1,543–18,690 ng/ml; three patients (37.5% had panhypopituitarism; median tumor diameter was 50 mm (41–60 mm. Five patients (62.5% had visual field defects and three had improvement during treatment; six patients (75% reached prolactin normalization, with a median time of 10.5 months (7–84 months and median dose of 2.0 mg/week (1.0 to 3.0 mg/week. One patient presented as a true incidentaloma. One patient presented a cerebrospinal fluid leakage during medical treatment and refused surgery, however this resolved with conservative measures. This case series illustrate a rare subtype of macroprolactinomas, the importance of considering unusual presentations at the diagnosis, the effectiveness of pharmacological treatment and its possible complications.

  2. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    Science.gov (United States)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  3. The Coetus Internationalis Patrum in the Second Vatican Council: presentation and results of a survey

    Directory of Open Access Journals (Sweden)

    Philippe Roy-Lysencourt

    2015-07-01

    Full Text Available The Coetus Internationalis Patrum (CIP, chaired by Mgr. Lefebvre, was the main group of opponents to the general spirit of Vatican II. In this article, the author briefly exposes his research on the subject at hand; this research culminated in the writing of a doctoral thesis defended on November 3, 2011. After making a history of research on the topic at hand and having presented the sources used, the author describes the organization, activity and CIP strategy, to then evaluate its impact on the Council schemes.

  4. Presentations from the Aeroelastic Workshop – latest results from AeroOpt

    DEFF Research Database (Denmark)

    Hansen, Morten Hartvig

    This report contains the slides of the presentations at the Aeroelastic Workshop held at Risø-DTU for the wind energy industry in Denmark on January 27, 2011. The scientific part of the agenda at this workshop was • Anisotropic beam element in HAWC2 for modelling of composite lay-ups (Taeseong Kim...... (Robert Mikkelsen) • Potential of fatigue and extreme load reductions on swept blades using HAWC2 (David Verelst) • Aeroelastic modal analysis of backward swept blades using HAWCStab2 (Morten H. Hansen) • Aeroelastic rotor design minimizing the loads (Christian Bak) • A small study of flat back airfoils...

  5. Results of site validation experiments. Volume II. Supporting documents 5 through 14

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    Volume II contains the following supporting documents: Summary of Geologic Mapping of Underground Investigations; Logging of Vertical Coreholes - ''Double Box'' Area and Exploratory Drift; WIPP High Precision Gravity Survey; Basic Data Reports for Drillholes, Brine Content of Facility Internal Strata; Mineralogical Content of Facility Interval Strata; Location and Characterization of Interbedded Materials; Characterization of Aquifers at Shaft Locations; and Permeability of Facility Interval Strate.

  6. Repetitive Cyclic Potentiodynamic Polarization Scan Results for Reduced Sample Volume Testing

    Energy Technology Data Exchange (ETDEWEB)

    LaMothe, Margaret E. [Washington River Protection Solutions, Richland, WA (United States)

    2016-03-15

    This report is the compilation of data gathered after repetitively testing simulated tank waste and a radioactive tank waste sample using a cyclic potentiodynamic polarization (CPP) test method to determine corrosion resistance of metal samples. Electrochemistry testing of radioactive tank samples is often used to assess the corrosion susceptibility and material integrity of waste tank steel. Repetitive testing of radiological tank waste is occasionally requested at 222-S Laboratory due to the limited volume of radiological tank sample received for testing.

  7. Screening Analysis : Volume 2, Impact Results (Columbia River System Operation Review).

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    Detailed results from all of the work groups are presented in this chapter. Ninety alternatives were analyzed during the screening process. Three of the alternative represent various base cases and are used for comparison purposes. The other 87 alternatives represent a wide variety of operational possibilities ranging from current operations to emphasizing a single river use to compromise operations that attempt to accommodate the multiple uses. Every possible alternative suggested during the screening phase was considered. Each alternative was given an abbreviated name, a number and assigned by ROSE to either the Corps (C) or BPA (B) for hydroregulation modeling. A list of the alternatives with its number and hydroregulation assignment is given below. The results in this chapter are presented in numerical order. The first 3 letters in the name identify which work group suggested the alternative. The format for the results includes a brief description of each alternative, a tabulation of the screening calculations organized by work group, and observations/comments on the alternative by the work groups. The description summarizes the key operational requirements for the alternative and was taken directly from the instructions given to the hydroregulation modelers.

  8. Severe global amnesia presenting as Wernicke-Korsakoff syndrome but resulting from atypical lesions.

    Science.gov (United States)

    Welch, L W; Nimmerrichter, A; Kessler, R; King, D; Hoehn, R; Margolin, R; Martin, P R

    1996-03-01

    A female alcoholic presented with Wernicke's encephalopathy subsequent to administration of diazepam and glucose (without thiamine) for treatment of withdrawal seizures. Nystagmus and cerebellar ataxia quickly resolved when administered thiamine, although severe global amnesia consistent with Korsakoff's syndrome persisted. Magnetic resonance imaging (MRI) revealed infarction of the right temporal lobe with hippocampal atrophy, but no lesions of thalamus or atrophy of mammillary bodies. Positron emission tomography (PET) confirmed decreased cerebral metabolic rates for glucose (CMRglu) in the right temporal lobe corresponding to MRI findings, but also significant metabolic asymmetry of dorsal thalamus, i.e. reduced CMRglu in left versus right. This patient is unique in that neuroradiological findings revealed intact mammillary bodies and suggest asymmetrical dysfunctions (structural right temporal and functional left diencephalic) to produce her profound amnesia.

  9. Erythropoietin assay: present status of methods, pitfalls, and results in polycythemic disorders.

    Science.gov (United States)

    Popovic, W J; Adamson, J W

    1978-01-01

    Mammalian erythropoiesis is regulated primarily by the hormone erythropoietin (ESP). Studies of ESF have provided information about its biochemistry and its role in regulating hemoglobin synthesis. Such studies rely on assays for erythropoietic activity in biological fluid. The assay which has proven most valuable and is used most widely is based upon the incorporation of radioactive iron into newly-formed red cells of polycythemic mice. While this assay has gained wide acceptance, it is expensive, cumbersome, imprecise, and insensitive, capable of reliably detecting no less than 50 milliunits of erythropoietin. Improvements in assay techniques will require new methodology relying primarily on immunologic recognition for the determination of hormone activity. Currently under development and in experimental use are radioimmunoassays and a hemagglutination inhibition assay. While work has progressed in these areas, these assays are not of proven value at present and meaningful physiological correlations have not emerged from their use. Alternatively, assays for hormone activity using suspensions of hematopoietic cells and the measurement of incorporation of radioactive isotopes into hemoglobin have provided both improvement in sensitivity and precision. The disadvantage of these types of assays is that they are sensitive to factors other than ESF and may give misleading information, depending on whether the factors present stimulate or inhibit cellular proliferation and hemoglobin synthesis. While such techniques may provide a temporary solution to some problems associated with assaying ESF for purification or physiological studies, they are not the best answer to the overall problem of hormone detection and characterization. The most important contribution to this field will be the availability of large amounts of highly purified and well-characterized ESF.

  10. Fluctuation in measurements of pulmonary nodule under tidal volume ventilation on four-dimensional computed tomography: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Tateishi, Ukihide [National Cancer Center Hospital, Division of Diagnostic Radiology, Chuo-ku, Tokyo (Japan); Tsukagoshi, Shinsuke; Inokawa, Hiroyasu; Okumura, Miwa [Toshiba Medical Systems Corporation, CT Systems Development, Otawara (Japan); Moriyama, Noriyuki [National Cancer Center, Division of Cancer Screening, Research Center for Cancer Prevention and Screening, Tokyo (Japan)

    2008-10-15

    The present study aimed to assess the feasibility of four-dimensional (4D) chest computed tomography (CT) under tidal volume ventilation and the impact of respiratory motion on quantitative analysis of CT measurements. Forty-four pulmonary nodules in patients with metastatic disease were evaluated. CT examinations were performed using a 256 multidetector-row CT (MDCT) unit. Volume data were obtained from the lower lung fields (128 mm) above the diaphragm during dynamic CT acquisition. The CT parameters used were 120 kV, 100 or 150 mA, 0.5 s{sup -1}, and 0.5 mm collimation. Image data were reconstructed every 0.1 s during one respiratory cycle by a 180 reconstruction algorithm for four independent fractions of the respiratory cycle. Pulmonary nodules were measured along their longest and shortest axes using electronic calipers. Automated volumetry was assessed using commercially available software. The diameters of long and short axes in each frame were 9.0-9.6 mm and 7.1-7.5 mm, respectively. There was fluctuation of the long axis diameters in the third fraction. The mean volume in each fraction ranged from 365 to 394 mm{sup 3}. Statistically significant fluctuation was also found in the third fraction. 4D-CT under tidal volume ventilation is feasible to determine diameter or volume of the pulmonary nodule. (orig.)

  11. Impact of the volume of gaseous phase in closed reactors on ANC results and modelling

    Science.gov (United States)

    Drapeau, Clémentine; Delolme, Cécile; Lassabatere, Laurent; Blanc, Denise

    2016-04-01

    The understanding of the geochemical behavior of polluted solid materials is often challenging and requires huge expenses of time and money. Nevertheless, given the increasing amounts of polluted solid materials and related risks for the environment, it is more and more crucial to understand the leaching of majors and trace metals elements from these matrices. In the designs of methods to quantify pollutant solubilization, the combination of experimental procedures with modeling approaches has recently gained attention. Among usual methods, some rely on the association of ANC and geochemical modeling. ANC experiments - Acid Neutralization Capacity - consists in adding known quantities of acid or base to a mixture of water and contaminated solid materials at a given liquid / solid ratio in closed reactors. Reactors are agitated for 48h and then pH, conductivity, redox potential, carbon, majors and heavy metal solubilized are quantified. However, in most cases, the amounts of matrix and water do not reach the total volume of reactors, leaving some space for air (gaseous phase). Despite this fact, no clear indication is given in standard procedures about the effect of this gaseous phase. Even worse, the gaseous phase is never accounted for when exploiting or modeling ANC data. The gaseous phase may exchange CO2 with the solution, which may, in turn, impact both pH and element release. This study lies within the most general framework for the use of geochemical modeling for the prediction of ANC results for the case of pure phases to real phase assemblages. In this study, we focus on the effect of the gaseous phase on ANC experiments on different mineral phases through geochemical modeling. To do so, we use PHREEQC code to model the evolution of pH and element release (including majors and heavy metals) when several matrices are put in contact with acid or base. We model the following scenarios for the gaseous phase: no gas, contact with the atmosphere (open system

  12. Present results of geochemical prospecting of the Strieborná vein deposit

    Directory of Open Access Journals (Sweden)

    Kondela Julián

    1998-12-01

    Full Text Available ″Strieborná vein″ is the deposit in the Rožnava ore area.The vein structure is created by older siderite and younger quartz-sulphidic mineral associacion. A prevailing mineral from the group of sulphide ones is tetrahedrite. The chemical composition of tetrahedrit is various. Economically significant elements for mining are silver and copper. The knowing a detailed distribution of Ag and Cu is very important for the further development and geological prospecting in the future. On the enclosed 3D (block diagrams is show, by means of izolines, the distribution of Ag and Cu and results of geochemical prospecting achieved so far.

  13. The present status and future growth of maintenance in US manufacturing: results from a pilot survey

    Directory of Open Access Journals (Sweden)

    Jin Xiaoning

    2016-01-01

    Full Text Available A research study was conducted (1 to examine the practices employed by US manufacturers to achieve productivity goals and (2 to understand what level of intelligent maintenance technologies and strategies are being incorporated into these practices. This study found that the effectiveness and choice of maintenance strategy were strongly correlated to the size of the manufacturing enterprise; there were large differences in adoption of advanced maintenance practices and diagnostics and prognostics technologies between small and medium-sized enterprises (SMEs. Despite their greater adoption of maintenance practices and technologies, large manufacturing organizations have had only modest success with respect to diagnostics and prognostics and preventive maintenance projects. The varying degrees of success with respect to preventative maintenance programs highlight the opportunity for larger manufacturers to improve their maintenance practices and use of advanced prognostics and health management (PHM technology. The future outlook for manufacturing PHM technology among the manufacturing organizations considered in this study was overwhelmingly positive; many manufacturing organizations have current and planned projects in this area. Given the current modest state of implementation and positive outlook for this technology, gaps, future trends, and roadmaps for manufacturing PHM and maintenance strategy are presented.

  14. The presentation of the results of Alexander von Humboldt's voyage to Carlos IV

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Puig-Samper

    2016-05-01

    Full Text Available Resumen  Desde nuestras primeras investigaciones sobre la estancia de Alexander von Humboldt en España siempre nos sorprendió la ausencia de una mínima relación posterior del sabio prusiano con la corona española y sus autoridades. Iniciada una nueva investigación, encontramos que efectivamente se produjo el envío de un primer trabajo a Carlos IV desde Roma acompañado de una carta de gratitud por la protección recibida durante su viaje americano y de sumisión a la corona española, que ahora presentamos.   Summary Ever since our first research into Alexander von Humboldt's stay in Spain, the absence of an ensuing relationship between the wise Prussian and the Spanish Crown and Authorities had always surprised us. On starting new research, we found that indeed he sent his first work to Carlos IV from Rome accompanied by a letter of gratitude for the protection he had received during his American trip and submission to the Spanish Crown, which we now present. This first literary fruit of his voyage, which Alexander von Humboldt alluded to in the letter is the first instalment of his work Plantes Équinoxiales, Recueillies au Mexique, dans l’ile de Cuba, dans les provinces de Caracas, de Cumana etc., published in Paris in 1805.   Zusammenfassung Seit unseren ersten Forschungen über den Aufenthalt Alexander von Humboldts in Spanien hat uns das Fehlen einer hieran anschließenden Beziehung des preußischen Wissenschaftlers mit der spanischen Krone und ihren Behörden erstaunt. Im Laufe einer erneuten Aufnahme der Forschung, haben wir nun entdeckt, dass Humboldt in der Tat von Rom aus eine erste Arbeit an Karl IV gesandt hatte, zusammen mit einem Schreiben des Dankes (für den während der amerikanischen Reise erhaltenen Schutz sowie seiner Unterordnung unter die spanische Krone, das wir nun präsentieren. Das erste literarische Ergebnis seiner Reise, auf das Humboldt in diesem Brief verweist, ist der erste Faszikel seines Werkes

  15. Present Status and Results from the KAERI Compact THz FEL Facility

    CERN Document Server

    Jeong, Y U; Lee, B C; Park, S H

    2005-01-01

    We have developed a laboratory-scale users facility with a compact terahertz (THz) free electron laser (FEL). The FEL operates in the wavelength range of 100-1200 μm, which corresponds to 0.3-3 THz. The peak power of the FEL micropulse having 30 ps pulse duration is 1 kW and the pulse energy of the 3-μs-FEL-macropulse is approximately 0.3 mJ. The main application of the FEL is THz imaging for bio-medical researches. Transmitted THz imaging of various samples including bugs have been measured. The samples were scanned by a 2-dimensional stage at the focal point of the THz beam. The bugs were not dry because they were killed just before experiments. We could get the transmitted THz imaging of the bugs at 3 THz with the high power THz FEL. THz spectral characteristics of several materials have been studied by the FEL and a THz FTIR spectrometer. We will introduce recent results on the imaging and spectroscopy by the THz FEL.

  16. Campaigned GPS on Present-Day Crustal Deformation in Northernmost Longitudinal Valley Preliminary Results, Hualien Taiwan

    Directory of Open Access Journals (Sweden)

    Chia-Yu Chen

    2014-01-01

    Full Text Available The Longitudinal Valley in Eastern Taiwan sits at the collision suture between the Eurasian and Philippine Sea plates. Based on repeated GPS campaigned measurements from 25 stations six times in 2007 - 2009, we characterize the surface deformation in the northernmost Longitudinal Valley where the Coastal Range of the Philippine Sea plate turns northward diving under the Eurasian plate producing two major active faults: the Milun fault and the Longitudinal Valley fault. We reconstructed a GPS velocity field and conducted strain analyses and elastic block modeling. Our results suggest a rapid clockwise rotation of 33° Myr-1 and an eastward tectonic escape in the small Hualien City block (HUAL area of ~10 × 10 km, which is apparently detached from the regional rotating RYUK block defined by previous studies. We interpret it as being initiated locally by the northwest indentation of the Coastal Range, which pushed the HUAL block to move upward and eastward. According to our strain analyses, the HUAL block shows a significant internal elastic strain inside the Milun Tableland, the hanging wall of the Milun fault. No significant deformation was observed across the surface trace of the fault, indicating that the Milun fault is now probably locked in the near surface. The deformation in the footwall of the fault was accommodated by pure-shear strain with a major NNW-compression and a minor ENE-extension. The deformation in the hanging wall is characterized by simple-shear strain with ENE-extension in its northern part and little deformation in the southern part, separated by a little known NW-trending active fault zone (Dongmingyi fault, which needs further investigation.

  17. A study of toxic emissions from a coal-fired power plant: Niles Station Boiler No. 2. Volume 1, Sampling/results/special topics: Final report

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    This study was one of a group of assessments of toxic emissions from coal-fired power plants, conducted for US Department of Energy, Pittsburgh Energy Technology Center (DOE-PETC) during 1993. The motivation for those assessments was the mandate in the 1990 Clean Air Act Amendments that a study be made of emissions of hazardous air pollutants (HAPs) from electrical utilities. The results of this study will be used by the US Environmental Protection Agency to evaluate whether regulation of HAPs emissions from utilities is warranted. This report is organized in two volumes. Volume 1: Sampling/Results/Special Topics describes the sampling effort conducted as the basis for this study, presents the concentration data on toxic chemicals in the several power plant streams, and reports the results of evaluations and calculations conducted with those data. The Special Topics section of Volume 1 reports on issues such as comparison of sampling methods and vapor/particle distributions of toxic chemicals. Volume 2: Appendices include field sampling data sheets, quality assurance results, and uncertainty calculations. The chemicals measured at Niles Boiler No. 2 were the following: five major and 16 trace elements, including mercury, chromium, cadmium, lead, selenium, arsenic, beryllium, and nickel; acids and corresponding anions (HCl, HF, chloride, fluoride, phosphate, sulfate); ammonia and cyanide; elemental carbon; radionuclides; volatile organic compounds (VOC); semivolatile compounds (SVOC) including polynuclear aromatic hydrocarbons (PAH), and polychlorinated dioxins and furans; and aldehydes.

  18. Results of volume-staged fractionated Gamma Knife radiosurgery for large complex arteriovenous malformations: obliteration rates and clinical outcomes of an evolving treatment paradigm.

    Science.gov (United States)

    Franzin, Alberto; Panni, Pietro; Spatola, Giorgio; Vecchio, Antonella Del; Gallotti, Alberto L; Gigliotti, Carmen R; Cavalli, Andrea; Donofrio, Carmine A; Mortini, Pietro

    2016-12-01

    OBJECTIVE There are few reported series regarding volume-staged Gamma Knife radiosurgery (GKRS) for the treatment of large, complex, cerebral arteriovenous malformations (AVMs). The object of this study was to report the results of using volume-staged Gamma Knife radiosurgery for patients affected by large and complex AVMs. METHODS Data from 20 patients with large AVMs were prospectively included in the authors' AVM database between 2004 and 2012. A staging strategy was used when treating lesion volumes larger than 10 cm(3). Hemorrhage and seizures were the presenting clinical feature for 6 (30%) and 8 (40%) patients, respectively. The median AVM volume was 15.9 cm(3) (range 10.1-34.3 cm(3)). The mean interval between stages (± standard deviation) was 15 months (± 9 months). The median margin dose for each stage was 20 Gy (range 18-25 Gy). RESULTS Obliteration was confirmed in 8 (42%) patients after a mean follow-up of 45 months (range 19-87 months). A significant reduction (> 75%) of the original nidal volume was achieved in 4 (20%) patients. Engel Class I-II seizure status was reported by 75% of patients presenting with seizures (50% Engel Class I and 25% Engel Class II) after radiosurgery. After radiosurgery, 71.5% (5/7) of patients who had presented with a worsening neurological deficit reported a complete resolution or amelioration. None of the patients who presented acutely because of hemorrhage experienced a new bleeding episode during follow-up. One (5%) patient developed radionecrosis that caused sensorimotor hemisyndrome. Two (10%) patients sustained a bleeding episode after GKRS, although only 1 (5%) was symptomatic. High nidal flow rate and a time interval between stages of less than 11.7 months were factors significantly associated with AVM obliteration (p = 0.021 and p = 0.041, respectively). Patient age younger than 44 years was significantly associated with a greater than 75% reduction in AVM volume but not with AVM obliteration (p = 0

  19. Remedial investigation report for J-Field, Aberdeen Proving Ground, Maryland. Volume 1: Remedial investigation results

    Energy Technology Data Exchange (ETDEWEB)

    Yuen, C. R.; Martino, L. E.; Biang, R. P.; Chang, Y. S.; Dolak, D.; Van Lonkhuyzen, R. A.; Patton, T. L.; Prasad, S.; Quinn, J.; Rosenblatt, D. H.; Vercellone, J.; Wang, Y. Y.

    2000-03-14

    This report presents the results of the remedial investigation (RI) conducted at J-Field in the Edgewood Area of Aberdeen Proving Ground (APG), a U.S. Army installation located in Harford County, Maryland. Since 1917, activities in the Edgewood Area have included the development, manufacture, and testing of chemical agents and munitions and the subsequent destruction of these materials at J-Field by open burning and open detonation. These activities have raised concerns about environmental contamination at J-Field. This RI was conducted by the Environmental Conservation and Restoration Division, Directorate of Safety, Health and Environmental Division of APG, pursuant to requirements outlined under the Comprehensive Environmental Response, Compensation, and Liability Act, as amended (CERCLA). The RI was accomplished according to the procedures developed by the U.S. Environmental Protection Agency (EPA 1988). The RI provides a comprehensive evaluation of the site conditions, nature of contaminants present, extent of contamination, potential release mechanisms and migration pathways, affected populations, and risks to human health and the environment. This information will be used as the basis for the design and implementation of remedial actions to be performed during the remedial action phase, which will follow the feasibility study (FS) for J-Field.

  20. Hypofractionated stereotactic radiotherapy of acoustic neuroma. Volume changes and hearing results after 89-month median follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Kranzinger, Manfred; Fastner, Gerd [Paracelsus Medical University Clinics (PMU), University Clinic of Radiotherapy and Radio-Oncology, Salzburg County Hospital, Salzburg (Austria); Zehentmayr, Franz; Sedlmayer, Felix [Paracelsus Medical University Clinics (PMU), University Clinic of Radiotherapy and Radio-Oncology, Salzburg County Hospital, Salzburg (Austria); Salzburg County Hospital, Paracelsus Medical University Clinics, radART - Institute for Research and Development on Advanced Radiation Technologies, Salzburg (Austria); Oberascher, Gerhard [Paracelsus Medical University Clinics (PMU), University Clinic of Ear, Nose and Throat Diseases, Salzburg County Hospital, Salzburg (Austria); Merz, Florian; Rahim, Hassan [Salzburg County Hospital, Paracelsus Medical University Clinics, Medical Radiation Protection Unit, Salzburg (Austria); Nairz, Olaf [Clinic Bad Trissl, Oberaudorf (Germany)

    2014-09-15

    The goal of this work was to evaluate toxicity and local control following hypofractionated stereotactic radiation treatment with special focus on changes in tumor volume and hearing capacity. In all, 29 patients with unilateral acoustic neuroma were treated between 2001 and 2007 within a prospective radiation protocol (7 x 4 Gy ICRU dose). Median tumor volume was 0.9 ml. Follow-up started at 6 months and was repeated annually with MRI volumetry and audiometry. Hearing preservation was defined as preservation of Class A/B hearing according to the guidelines of the American Academy of Otolaryngology (1995). No patient had any intervention after a median imaging follow-up of 89.5 months, one patient showed radiological progression. Transient increase of tumor volume developed in 17/29 patients, whereas 22/29 patients (75.9 %) presented with a volume reduction at last follow-up. A total of 21 patients were eligible for hearing evaluation. Mean pure tone average (PTA) deteriorated from 39.3 to 65.9 dB and mean speech discrimination score (SDS) dropped from 74.3 to 38.1 %. The 5-year actuarial Class A/B hearing preservation rate was 50.0 ± 14.4 %. Radiation increases only minimally, if at all, the hearing deterioration which emerges by observation alone. Presbyacusis is not responsible for this deterioration. Transient tumor enlargement is common. Today radiation of small- and medium-sized acoustic neuroma can be performed with different highly conformal techniques as fractionated treatment or single low-dose radiosurgery with equal results regarding tumor control, hearing preservation, and side effects. Hypofractionation is more comfortable for the patient than conventional regimens and represents a serious alternative to frameless radiosurgery. (orig.) [German] Ziel der Studie war die Evaluierung der Toxizitaet und der lokalen Tumorkontrolle einer hypofraktionierten stereotaktischen Bestrahlung mit besonderem Augenmerk auf Veraenderungen von Tumorvolumen und

  1. Associations Between Family Adversity and Brain Volume in Adolescence: Manual vs. Automated Brain Segmentation Yields Different Results

    Directory of Open Access Journals (Sweden)

    Hannah Lyden

    2016-09-01

    Full Text Available Associations between brain structure and early adversity have been inconsistent in the literature. These inconsistencies may be partially due to methodological differences. Different methods of brain segmentation may produce different results, obscuring the relationship between early adversity and brain volume. Moreover, adolescence is a time of significant brain growth and certain brain areas have distinct rates of development, which may compromise the accuracy of automated segmentation approaches. In the current study, 23 adolescents participated in two waves of a longitudinal study. Family aggression was measured when the youths were 12 years old, and structural scans were acquired an average of 4 years later. Bilateral amygdalae and hippocampi were segmented using three different methods (manual tracing, FSL, and NeuroQuant. The segmentation estimates were compared, and linear regressions were run to assess the relationship between early family aggression exposure and all three volume segmentation estimates. Manual tracing results showed a positive relationship between family aggression and right amygdala volume, whereas FSL segmentation showed negative relationships between family aggression and both the left and right hippocampi. However, results indicate poor overlap between methods, and different associations between early family aggression exposure and brain volume depending on the segmentation method used.

  2. Associations between Family Adversity and Brain Volume in Adolescence: Manual vs. Automated Brain Segmentation Yields Different Results

    Science.gov (United States)

    Lyden, Hannah; Gimbel, Sarah I.; Del Piero, Larissa; Tsai, A. Bryna; Sachs, Matthew E.; Kaplan, Jonas T.; Margolin, Gayla; Saxbe, Darby

    2016-01-01

    Associations between brain structure and early adversity have been inconsistent in the literature. These inconsistencies may be partially due to methodological differences. Different methods of brain segmentation may produce different results, obscuring the relationship between early adversity and brain volume. Moreover, adolescence is a time of significant brain growth and certain brain areas have distinct rates of development, which may compromise the accuracy of automated segmentation approaches. In the current study, 23 adolescents participated in two waves of a longitudinal study. Family aggression was measured when the youths were 12 years old, and structural scans were acquired an average of 4 years later. Bilateral amygdalae and hippocampi were segmented using three different methods (manual tracing, FSL, and NeuroQuant). The segmentation estimates were compared, and linear regressions were run to assess the relationship between early family aggression exposure and all three volume segmentation estimates. Manual tracing results showed a positive relationship between family aggression and right amygdala volume, whereas FSL segmentation showed negative relationships between family aggression and both the left and right hippocampi. However, results indicate poor overlap between methods, and different associations were found between early family aggression exposure and brain volume depending on the segmentation method used. PMID:27656121

  3. Annual Proceedings of Selected Research and Development Papers Presented at the Annual Convention of the Association for Educational Communications and Technology (36th, Anaheim, California, 2013). Volume 1

    Science.gov (United States)

    Simonson, Michael, Ed.

    2013-01-01

    For the thirty-sixth year, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the annual AECT Convention in Anaheim, California. The Proceedings of AECT's Convention are published in two…

  4. Annual Proceedings of Selected Research and Development Papers Presented at the Annual Convention of the Association for Educational Communications and Technology (38th, Indianapolis, Indiana, 2015). Volume 1

    Science.gov (United States)

    Simonson, Michael, Ed.

    2015-01-01

    For the thirty-eighth time, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the annual AECT Convention in Indianapolis, Indiana. The Proceedings of AECT's Convention are published in two…

  5. Annual Proceedings of Selected Research and Development Papers Presented at the Annual Convention of the Association for Educational Communications and Technology (32nd, Louisville, KY, 2009). Volume 1

    Science.gov (United States)

    Simonson, Michael, Ed.

    2009-01-01

    For the thirty-second year, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the national AECT Convention in Louisville, Kentucky. The Proceedings of AECT's Convention are published in two…

  6. Annual Proceedings of Selected Research and Development Papers Presented at the Annual Convention of the Association for Educational Communications and Technology (37th, Jacksonville, Florida, 2014). Volume 1

    Science.gov (United States)

    Simonson, Michael, Ed.

    2014-01-01

    For the thirty-seventh year, the Research and Theory Division and the Division of Instructional Design of the Association for Educational Communications and Technology (AECT) sponsored the publication of these Proceedings. Papers published in this volume were presented at the annual AECT Convention in Jacksonville, Florida. This year's Proceedings…

  7. Annual Proceedings of Selected Research and Development Papers Presented at the Annual Convention of the Association for Educational Communications and Technology (36th, Anaheim, California, 2013). Volume 2

    Science.gov (United States)

    Simonson, Michael, Ed.

    2013-01-01

    For the thirty-sixth year, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the annual AECT Convention in Anaheim, California. The Proceedings of AECT's Convention are published in two…

  8. Annual Proceedings of Selected Research and Development Papers Presented at the Annual Convention of the Association for Educational Communications and Technology (33rd, Anaheim, California, 2010). Volume 1

    Science.gov (United States)

    Simonson, Michael, Ed.

    2010-01-01

    For the thirty-third year, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the national AECT Convention in Anaheim, California. The Proceedings of AECT's Convention are published in two…

  9. Annual Proceedings of Selected Research and Development Papers Presented at the Annual Convention of the Association for Educational Communications and Technology (35th, Louisville, Kentucky, 2012). Volume 2

    Science.gov (United States)

    Simonson, Michael, Ed.

    2012-01-01

    For the thirty-fifth year, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the national AECT Convention in Louisville, Kentucky. The Proceedings of AECT's Convention are published in two…

  10. Annual Proceedings of Selected Research and Development Papers Presented at the Annual Convention of the Association for Educational Communications and Technology (35th, Louisville, Kentucky, 2012). Volume 1

    Science.gov (United States)

    Simonson, Michael, Ed.

    2012-01-01

    For the thirty-fifth year, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the national AECT Convention in Louisville, Kentucky. The Proceedings of AECT's Convention are published in two…

  11. Annual Proceedings of Selected Research and Development Papers Presented at the National Convention of the Association for Educational Communications and Technology (28th, Orlando, Florida, 2005). Volume 1

    Science.gov (United States)

    Simonson, Michael, Ed.; Crawford, Margaret, Ed.

    2005-01-01

    For the twenty-eighth year, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the National AECT Convention in Orlando, Florida. The Proceedings of AECT's Convention are published in two…

  12. Annual Proceedings of Selected Research and Development Papers Presented at the National Convention of the Association for Educational Communications and Technology (28th, Orlando, Florida, 2005). Volume 2

    Science.gov (United States)

    Simonson, Michael, Ed.; Crawford, Margaret, Ed.

    2005-01-01

    For the twenty-eighth year, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the National AECT Convention in Orlando, Florida. The Proceedings of AECT's Convention are published in two…

  13. Gastrointestinal toxicity of vorinostat: reanalysis of phase 1 study results with emphasis on dose-volume effects of pelvic radiotherapy

    LENUS (Irish Health Repository)

    Bratland, Ase

    2011-04-08

    Abstract Background In early-phase studies with targeted therapeutics and radiotherapy, it may be difficult to decide whether an adverse event should be considered a dose-limiting toxicity (DLT) of the investigational systemic agent, as acute normal tissue toxicity is frequently encountered with radiation alone. We have reanalyzed the toxicity data from a recently conducted phase 1 study on vorinostat, a histone deacetylase inhibitor, in combination with pelvic palliative radiotherapy, with emphasis on the dose distribution within the irradiated bowel volume to the development of DLT. Findings Of 14 eligible patients, three individuals experienced Common Terminology Criteria of Adverse Events grade 3 gastrointestinal and related toxicities, representing a toxicity profile vorinostat has in common with radiotherapy to pelvic target volumes. For each study patient, the relative volumes of small bowel receiving radiation doses between 6 Gy and 30 Gy at 6-Gy intervals (V6-V30) were determined from the treatment-planning computed tomography scans. The single patient that experienced a DLT at the second highest dose level of vorinostat, which was determined as the maximum-tolerated dose, had V6-V30 dose-volume estimates that were considerably higher than any other study patient. This patient may have experienced an adverse radiation dose-volume effect rather than a toxic effect of the investigational drug. Conclusions When reporting early-phase trial results on the tolerability of a systemic targeted therapeutic used as potential radiosensitizing agent, radiation dose-volume effects should be quantified to enable full interpretation of the study toxicity profile. Trial registration ClinicalTrials.gov: NCT00455351

  14. The Evolution of P-wave Velocity in Fault Gouge: Initial Results for Samples from the SAFOD Volume.

    Science.gov (United States)

    Knuth, M. W.; Tobin, H. J.; Marone, C.

    2008-12-01

    We present initial results from a new technique for observing the evolution of elastic properties in sheared fault zone materials via acoustic wave velocity. The relationship between the mechanical strength of fault gouge and acoustic velocity during active deformation has important implications not only for a physical understanding of elasticity in deforming granular media, but also for the interpretation of the seismic velocity at the field scale. Experiments are conducted at atmospheric temperature and saturation state in a double-direct-shear testing apparatus, with normal stress stepped from 1 to 19 MPa to interrogate behavior during compaction, and sheared at a rate of 10 microns/second to observe changes in velocity with increasing strain. Tests are divided between those involving continuous shear to a displacement of 22.5 mm, and those with intervals of 3.75 mm shear separated by unloading and reloading sequences in normal stress. Velocity is measured by time-of-flight between two piezoelectric P-wave transducers set into the sample configuration on either side of the shearing layers. Samples tested include common laboratory standards for simulated fault gouge and field samples taken from representative localities in the 3D rock volume containing the San Andreas Fault Observatory at Depth experiment in Parkfield, California. The velocities of sand and clay end-member gouges are observed to behave differently under shear, and mixtures of quartz sand and montmorillonite behave differently from both end-member materials. Initial results suggest that particle sorting exerts a strong influence on both the absolute velocity and the evolution of velocity in response to increasing shear strain where the elastic properties of the grains are similar. We also observe a first-order relationship between the coefficient of friction and P-wave velocity that appears to be related to grain reorganization at the onset of shear following initial compaction.

  15. Catecholamine and volume therapy for cardiac surgery in Germany--results from a postal survey.

    Directory of Open Access Journals (Sweden)

    Christoph Sponholz

    Full Text Available Management of cardiac surgery patients is a very standardized procedure in respective local institutions. Yet only very limited evidence exists concerning optimal indication, safety and efficacy of hemodynamic monitoring catecholamine and fluid therapy.Between April and May 2013, all 81 German anaesthesia departments involved in cardiac surgery care were asked to participate in a questionnaire addressing the institutional specific current practice in hemodynamic monitoring, catecholamine and volume therapy.51 (63% questionnaires were completed and returned. All participating centers used basic hemodynamic monitoring (i.e. invasive arterial blood pressure and central venous pressure, supplemented by transesophageal echocardiography. Pulmonary arterial catheter and calibrated trend monitoring devices were also routinely available. In contrast, non-calibrated trend monitoring and esophageal doppler ultrasound devices were not commonly in use. Cerebral oximetry is increasingly emerging, but lacks clear indications. The majority of patients undergoing cardiac surgery, especially in university hospitals, required catecholamines during perioperative care, In case of low cardiac output syndrome, dobutamine (32%, epinephrine (30% or phosphodiesterase inhibitors (8% were first choice. In case of hypotension following vasoplegia, norepinephrine (96% represented the most common catecholamine. 88% of the participating centers reported regular use of colloid fluids, with hydroxyethyl starches (HES being first choice (64%.Choice of hemodynamic monitoring is homogenous throughout German centers treating cardiac surgery patients. Norepinephrine is the first line catecholamine in cases of decrease in peripheral vascular resistance. However, catecholamine choice for low cardiac output syndrome varies considerably. HES was the primary colloid used for fluid resuscitation. After conduct of this survey, HES use was restricted by European regulatory authorities in

  16. Army Synthetic Validity Project: Report of Phase 2 Results. Volume 1

    Science.gov (United States)

    1990-06-01

    Interest in Efficiency & Org. 394 198.59 28.42 Prformane Criterio Measure CEP: Core Technical Prof. 394 102.72 15.03 6-12 Army Syheric Validation...measures: The modeling of performance. Paper presented at the Second Annual Conference of the Society for Industrial and Organizational Psychology, Atlanta ...the Society of Industrial and Organizational Psychology, Atlanta . Peterson, N. G., Owens-Kurtz, C. K., Hoffman, R. G., Arabian, J. M. & Whetzel, D. L

  17. Economic evaluation of the Annual Cycle Energy System (ACES). Volume II. Detailed results. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-05-01

    The energy effectiveness and the economic viability of the ACES concept are examined. ACES is studied in a variety of different applications and compared to a number of conventional systems. The different applications are studied in two groups: the class of building into which the ACES is incorporated and the climatic region in which the ACES is located. Buildings investigated include single-family and multi-family residences and a commercial office building. The application of ACES to each of these building types is studied in Minneapolis, Atlanta, and Philadelphia. The economic evaluation of the ACES is based on a comparison of the present worth of the ACES to the present worth of conventional systems; namely, electric resistance heating, electric air conditioning, and electric domestic water heating; air-to-air heat pump and electric domestic water heating; oil-fired furnace, electric air conditioning, and electric domestic water heating; and gas-fired furnace, electric air conditioning, and gas domestic water heating.

  18. The reactive transport benchmark proposed by GdR MoMaS: presentation and first results

    Energy Technology Data Exchange (ETDEWEB)

    Carrayrou, J. [Institut de Mecanique des Fluides et des Solides, UMR ULP-CNRS 7507, 67 - Strasbourg (France); Lagneau, V. [Ecole des Mines de Paris, Centre de Geosciences, 77 - Fontainebleau (France)

    2007-07-01

    We present here the actual context of reactive transport modelling and the major numerical challenges. GdR MoMaS proposes a benchmark on reactive transport. We present this benchmark and some results obtained on it by two reactive transport codes HYTEC and SPECY. (authors)

  19. Nuclear Dynamics Consequence Analysis (NDCA) for the Disposal of Spent Nuclear Fuel in an Underground Geologic Repository--Volume 2: Methodology and Results

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, L.L.; Wilson, J.R.; Sanchez, L.C.; Aguilar, R.; Trellue, H.R.; Cochrane, K.; Rath, J.S.

    1998-10-01

    The US Department of Energy Office of Environmental Management's (DOE/EM's) National Spent Nuclear Fuel Program (NSNFP), through a collaboration between Sandia National Laboratories (SNL) and Idaho National Engineering and Environmental Laboratory (INEEL), is conducting a systematic Nuclear Dynamics Consequence Analysis (NDCA) of the disposal of SNFs in an underground geologic repository sited in unsaturated tuff. This analysis is intended to provide interim guidance to the DOE for the management of the SNF while they prepare for final compliance evaluation. This report presents results from a Nuclear Dynamics Consequence Analysis (NDCA) that examined the potential consequences and risks of criticality during the long-term disposal of spent nuclear fuel owned by DOE-EM. This analysis investigated the potential of post-closure criticality, the consequences of a criticality excursion, and the probability frequency for post-closure criticality. The results of the NDCA are intended to provide the DOE-EM with a technical basis for measuring risk which can be used for screening arguments to eliminate post-closure criticality FEPs (features, events and processes) from consideration in the compliance assessment because of either low probability or low consequences. This report is composed of an executive summary (Volume 1), the methodology and results of the NDCA (Volume 2), and the applicable appendices (Volume 3).

  20. Management of Peptic Ulcer Bleeding in Different Case Volume Workplaces: Results of a Nationwide Inquiry in Hungary

    Directory of Open Access Journals (Sweden)

    István Rácz

    2012-01-01

    Full Text Available The aim of this study was to conduct a national survey to evaluate the recent endoscopic treatment and drug therapy of peptic ulcer bleeding (PUB patients and to compare practices in high and low case volume Hungarian workplaces. A total of 62 gastroenterology units participated in the six-month study. A total of 3033 PUB cases and a mean of 8.15±3.9 PUB cases per month per unit were reported. In the 23 high case volume units (HCV, there was a mean of 12.9±5.4 PUB cases/month, whereas in the 39 low case volume units (LCV, a mean of 5.3±2.9 PUB cases/month were treated during the study period. In HCV units, endoscopic therapies for Forrest Ia, Ib, and IIa ulcers were significantly more often used than in LCV units (86% versus 68%; P=0.001. Among patients with stigmata of recent haemorrhage (Forrest I, II, bolus + continuous infusion PPI was given significantly more frequently in HCV than in LCV units (49.6% versus 33.2%; P=0.001. Mortality in HCV units was less than in LCV units (2.7% versus 4.3%; P=0.023. The penetration of evidence-based recommendations for PUB management is stronger in HCV units resulting lower mortality.

  1. Study of 320-slice dynamic volume CT perfusion in different pathologic types of kidney tumor: preliminary results.

    Directory of Open Access Journals (Sweden)

    Chao Chen

    Full Text Available OBJECTIVE: To investigate microcirculatory differences between pathologic types of kidney tumor using 320-slice dynamic volume CT perfusion. METHODS: Perfusion imaging with 320-slice dynamic volume CT was prospectively performed in 85 patients with pathologically proven clear cell renal cell carcinoma (RCC (n = 66, papillary RCC (n = 7, chromophobe RCC (n = 5, angiomyolipoma (AML with minimal fat (n = 7, or RCC (n = 78. Equivalent blood volume (Equiv BV, permeability surface-area product (PS; clearance/unit volume = permeability, and blood flow (BF of tumor and normal renal cortex were measured and analyzed. Effective radiation dose was calculated. RESULTS: There was a significant difference in all three parameters between tumor and normal renal cortex (P<0.001. Equiv BV was significantly different between RCC and AML with minimal fat (P = 0.038 and between clear cell RCC and AML with minimal fat (P<0.001. Mean Equiv BV and BF were significantly higher in clear cell RCC than in papillary RCC (P<0.001 for both and mean Equiv BV was higher in clear cell RCC than in chromophobe RCC (P<0.001. The effective radiation dose of the CT perfusion protocol was 18.5 mSv. CONCLUSION: Perfusion imaging using 320-slice dynamic volume CT can be used to evaluate hemodynamic features of the whole kidney and kidney tumors, which may be useful in the differential diagnosis of these four pathologic types of kidney tumor.

  2. Results of temperature gradient and heat flow in Santiam Pass Area, Oregon, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Cox, B.L.; Gardner, M.C.; Koenig, J.B.

    1981-08-01

    The conclusions of this report are: (1) There is a weakly defined thermal anomaly within the area examined by temperature-gradient holes in the Santiam Pass area. This is a relict anomaly showing differences in permeability between the High Cascades and Western Cascades areas, more than a fundamental difference in shallow crustal temperatures. (2) The anomaly as defined by the 60 F isotherms at 400 feet follows a north-south trend immediately westward of the Cascade axis in the boundary region. It is clear that all holes spudded into High Cascades rocks result in isothermal and reversal gradients. Holes spudded in Western Cascades rocks result in positive gradients. (3) Cold groundwater flow influences and masks temperature gradients in the High Cascades to a depth of at least 700 feet, especially eastward from the major north-south trending faults. Pleistocene and Holocene rocks are very permeable aquifers. (4) Shallow gradient drilling in the lowlands westward of the faults provides more interpretable information than shallow drilling in the cold-water recharge zones. Topographic and climatological effects can be filtered out of the temperature gradient results. (5) The thermal anomaly seems to have 2 centers: one in the Belknap-Foley area, and one northward in the Sand Mountain area. The anomalies may or may not be connected along a north-south trend. (6) A geothermal effect is seen in holes downslope of the Western-High Cascade boundary. Mixing with cold waters is a powerful influence on temperature gradient data. (7) The temperature-gradient program has not yet examined and defined the geothermal resources potential of the area eastward of the Western Cascades-High Cascades boundary. Holes to 1500-2000 feet in depth are required to penetrate the high permeability-cold groundwater regime. (8) Drilling conditions are unfavorable. There are very few accessible level drill sites. Seasonal access problems and environmental restrictions together with frequent lost

  3. Hazard Ranking System evaluation of CERCLA (Comprehensive Environmental Response, Compensation, and Liability Act) inactive waste sites at Hanford: Volume 1, Evaluation methods and results

    Energy Technology Data Exchange (ETDEWEB)

    Stenner, R.D.; Cramer, K.H.; Higley, K.A.; Jette, S.J.; Lamar, D.A.; McLaughlin, T.J.; Sherwood, D.R.; Van Houten, N.C.

    1988-10-01

    The purpose of this report is to formally document the individual site Hazard Ranking System (HRS) evaluations conducted as part of the preliminary assessment/site inspection (PA/SI) activities at the US Department of Energy (DOE) Hanford Site. These activities were carried out pursuant to the DOE orders that describe the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Program addressing the cleanup of inactive waste sites. These orders incorporate the US Environmental Protection Agency methodology, which is based on the Superfund Amendments and Reauthorization Act of 1986 (SARA). The methodology includes six parts: PA/SI, remedial investigation/feasibility study, record of decision, design and implementation of remedial action, operation and monitoring, and verification monitoring. Volume 1 of this report discusses the CERCLA inactive waste-site evaluation process, assumptions, and results of the HRS methodology employed. Volume 2 presents the data on the individual CERCLA engineered-facility sites at Hanford, as contained in the Hanford Inactive Site Surveillance (HISS) Data Base. Volume 3 presents the data on the individual CERCLA unplanned-release sites at Hanford, as contained in the HISS Data Base. 34 refs., 43 figs., 47 tabs.

  4. Fully-automated left ventricular mass and volume MRI analysis in the UK Biobank population cohort: evaluation of initial results.

    Science.gov (United States)

    Suinesiaputra, Avan; Sanghvi, Mihir M; Aung, Nay; Paiva, Jose Miguel; Zemrak, Filip; Fung, Kenneth; Lukaschuk, Elena; Lee, Aaron M; Carapella, Valentina; Kim, Young Jin; Francis, Jane; Piechnik, Stefan K; Neubauer, Stefan; Greiser, Andreas; Jolly, Marie-Pierre; Hayes, Carmel; Young, Alistair A; Petersen, Steffen E

    2017-08-23

    UK Biobank, a large cohort study, plans to acquire 100,000 cardiac MRI studies by 2020. Although fully-automated left ventricular (LV) analysis was performed in the original acquisition, this was not designed for unsupervised incorporation into epidemiological studies. We sought to evaluate automated LV mass and volume (Siemens syngo InlineVF versions D13A and E11C), against manual analysis in a substantial sub-cohort of UK Biobank participants. Eight readers from two centers, trained to give consistent results, manually analyzed 4874 UK Biobank cases for LV end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF) and LV mass (LVM). Agreement between manual and InlineVF automated analyses were evaluated using Bland-Altman analysis and the intra-class correlation coefficient (ICC). Tenfold cross-validation was used to establish a linear regression calibration between manual and InlineVF results. InlineVF D13A returned results in 4423 cases, whereas InlineVF E11C returned results in 4775 cases and also reported LVM. Rapid visual assessment of the E11C results found 178 cases (3.7%) with grossly misplaced contours or landmarks. In the remaining 4597 cases, LV function showed good agreement: ESV -6.4 ± 9.0 ml, 0.853 (mean ± SD of the differences, ICC) EDV -3.0 ± 11.6 ml, 0.937; SV 3.4 ± 9.8 ml, 0.855; and EF 3.5 ± 5.1%, 0.586. Although LV mass was consistently overestimated (29.9 ± 17.0 g, 0.534) due to larger epicardial contours on all slices, linear regression could be used to correct the bias and improve accuracy. Automated InlineVF results can be used for case-control studies in UK Biobank, provided visual quality control and linear bias correction are performed. Improvements between InlineVF D13A and InlineVF E11C show the field is rapidly advancing, with further improvements expected in the near future.

  5. Control of hydrogen sulfide emission from geothermal power plants. Volume I. Summary of results. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Brown, F.C.; Harvey, W.W.; Warren, R.B.

    1979-01-01

    A program of laboratory and pilot plant tests, detailed process and project engineering work, and process engineering and economic evaluation studies has been carried out in support of the design of a test facility for demonstration of the copper sulfate process for the removal of hydrogen sulfide from geothermal steam at turbine upstream conditions. A demonstration plant has been designed which is capable of removing 99% of the H/sub 2/S, 90% of the NH/sub 3/, and significant amounts of H/sub 3/BO/sub 3/ and particulates from 100,000 lb/hr of geothermal steam of The Geysers composition. Criteria for the mechanical and process design of the scrubber have been confirmed in field tests of fifty hours duration on an eight-inch diameter scrubber at PG and E's Unit No. 7, The Geysers. The background of the problem and the technical approach to its solution, the scope and results of the first-phase laboratory testing, the scope and results of the experimental and analytical studies carried out in the second phase, and a description of the configuration of the demonstration plant and the test plan for its operation are summarized. (MHR)

  6. The European Military Environment: NATO and the Warsaw Pact. Volume 1. The European Environment (Update: 1982-Present).

    Science.gov (United States)

    1987-04-01

    17). Finally, to calm European fcars that SDI might, result in an overwhelming technological gap b,’twten the U.S. and F,7rope, the Reagan...European fears that SLI might rsult in an overwhelming technological gap between the U.S. and Europe, the Reagan administration announced European

  7. Models of cognitive behavior in nuclear power plant personnel. A feasibility study: summary of results. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Woods, D.D.; Roth, E.M.; Hanes, L.F.

    1986-07-01

    This report summarizes the results of a feasibility study to determine if the current state of models of human cognitive activities can serve as the basis for improved techniques for predicting human error in nuclear power plants emergency operations. Based on the answer to this question, two subsequent phases of research are planned. Phase II is to develop a model of cognitive activities, and Phase III is to test the model. The feasibility study included an analysis of the cognitive activities that occur in emergency operations and an assessment of the modeling concepts/tools available to capture these cognitive activities. The results indicated that a symbolic processing (or artificial intelligence) model of cognitive activities in nuclear power plants is both desirable and feasible. This cognitive model can be built upon the computational framework provided by an existing artificial intelligence system for medical problem solving, called Caduceus. The resulting cognitive model will increase the capability to capture the human contribution to risk in probabilistic risk assessment studies. Volume 1 summarizes the major findings and conclusions of the study. Volume 2 provides a complete description of the methods and results, including a synthesis of the cognitive activities that occur during emergency operations, and a literature review on cognitive modeling relevant to nuclear power plants. 19 refs.

  8. A study of toxic emissions from a coal-fired power plant utilizing an ESP/Wet FGD system. Volume 1, Sampling, results, and special topics: Final report

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    This was one of a group of assessments of toxic emissions from coal-fired power plants, conducted for DOE-PETC in 1993 as mandated by the 1990 Clean Air Act. It is organized into 2 volumes; Volume 1 describes the sampling effort, presents the concentration data on toxic chemicals in several power plant streams, and reports the results of evaluations and calculations. The study involved solid, liquid, and gaseous samples from input, output, and process streams at Coal Creek Station Unit No. 1, Underwood, North Dakota (1100 MW mine-mouth plant burning lignite from the Falkirk mine located adjacent to the plant). This plant had an electrostatic precipitator and a wet scrubber flue gas desulfurization unit. Measurements were conducted on June 21--24, 26, and 27, 1993; chemicals measured were 6 major and 16 trace elements (including Hg, Cr, Cd, Pb, Se, As, Be, Ni), acids and corresponding anions (HCl, HF, chloride, fluoride, phosphate, sulfate), ammonia and cyanide, elemental C, radionuclides, VOCs, semivolatiles (incl. PAH, polychlorinated dioxins, furans), and aldehydes. Volume 2: Appendices includes process data log sheets, field sampling data sheets, uncertainty calculations, and quality assurance results.

  9. Ballast Water Treatment, U.S. Great Lakes Bulk Carrier Engineering and Cost Study. Volume 1: Present Conditions

    Science.gov (United States)

    2013-11-01

    ballast in 24 hours or less will have relatively low impact on current operations. The results also show that there are considerable operational...deck and into the deckhouse above the main deck; it consists of a loop- type elevating conveyor and boom conveyor (Figure A-3). The pilothouse is aft...the cargo flows onto a conveyor belt (one port and one starboard, that carry the cargo aft) dropping onto a single transverse belt, feeding the

  10. Long-term results of preventive embolization of renal angiomyolipomas: evaluation of predictive factors of volume decrease

    Energy Technology Data Exchange (ETDEWEB)

    Hocquelet, A.; Cornelis, F.; Le Bras, Y.; Meyer, M.; Tricaud, E.; Lasserre, A.S.; Grenier, N. [Centre Hospitalier Universitaire Pellegrin, Diagnostic and Therapeutic Urology and Vascular Imaging, Bordeaux (France); Ferriere, J.M.; Robert, G. [Centre Hospitalier Universitaire Pellegrin, Urology Service, Bordeaux (France)

    2014-08-15

    To evaluate the efficacy of selective arterial embolization (SAE) of angiomyolipomas based on the percentage volume reduction after embolization and to identify predictive factors of volume decrease. Patients receiving prophylactic SAE of renal angiomyolipomas were included retrospectively over 3 years. The volume change after SAE and haemorrhagic or surgical events were recorded. Initial tumour volume, percentage tumour fat content, mean tumour density, embolic agent used, number of angiomyolipomas and tuberous sclerosis disease were evaluated as predictive factors of volume decrease. A total of 19 patients with 39 angiomyolipomas were included with median follow-up of 28 months (interquartile range 21-37 months). All treatments were technically successful (92 % primary and 8 % secondary). No distal bleeding or any increase in size or surgical nephrectomy after SAE was recorded. Mean volume reduction was 72 % (±24 %). Volumes before SAE (R{sup 2} = 0.276; p = 0.001), percentage fat content (R{sup 2} = 0.612; p < 0.0001) and mean angiomyolipoma density (R{sup 2} = 0.536; p < 0.0001) were identified as predictive factors of volume decrease. In multivariate regression, only percentage fat content influenced volume decreases. SAE is an efficient treatment for angiomyolipoma devascularisation and volume reduction. A significant reduction of volume is modulated by the initial volume and tissue composition of the tumour. (orig.)

  11. Volume Entropy

    CERN Document Server

    Astuti, Valerio; Rovelli, Carlo

    2016-01-01

    Building on a technical result by Brunnemann and Rideout on the spectrum of the Volume operator in Loop Quantum Gravity, we show that the dimension of the space of the quadrivalent states --with finite-volume individual nodes-- describing a region with total volume smaller than $V$, has \\emph{finite} dimension, bounded by $V \\log V$. This allows us to introduce the notion of "volume entropy": the von Neumann entropy associated to the measurement of volume.

  12. Effectiveness of quantitative MAA SPECT/CT for the definition of vascularized hepatic volume and dosimetric approach: phantom validation and clinical preliminary results in patients with complex hepatic vascularization treated with yttrium-90-labeled microspheres.

    Science.gov (United States)

    Garin, Etienne; Lenoir, Laurence; Rolland, Yan; Laffont, Sophie; Pracht, Marc; Mesbah, Habiba; Porée, Philippe; Ardisson, Valérie; Bourguet, Patrick; Clement, Bruno; Boucher, Eveline

    2011-12-01

    The goal of this study was to assess the use of quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) analysis for vascularized volume measurements in the use of the yttrium-90-radiolabeled microspheres (TheraSphere). A phantom study was conducted for the validation of SPECT/CT volume measurement. SPECT/CT quantitative analysis was used for the measurement of the volume of distribution of the albumin macroaggregates (MAA; i.e., the vascularized volume) in the liver and the tumor, and the total activity contained in the liver and the tumor in four consecutive patients presenting with a complex liver vascularization referred for a treatment with TheraSphere. SPECT/CT volume measurement proved to be accurate (mean error data, instead of angiography and CT data, results in modifying the activity injected for three treatments of eight. Moreover, quantitative analysis of SPECT/CT allows us to calculate the absorbed dose in the tumor and in the healthy liver, leading to doubling of the injected activity for one treatment of eight. MAA SPECT/CT is accurate for volume measurements. It provides a valuable contribution to the therapeutic planning of patients presenting with complex hepatic vascularization, in particular for calculating the vascularized liver volume, the activity to be injected and the absorbed doses. Studies should be conducted to assess the role of quantitative MAA/SPECT CT in therapeutic planning.

  13. Present Status And First Results of the Final Focus Beam Line at the KEK Accelerator Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Bambade, P.; /Orsay /KEK, Tsukuba; Alabau Pons, M.; /Valencia U., IFIC; Amann, J.; /SLAC; Angal-Kalinin, D.; /Daresbury; Apsimon, R.; /Oxford U., JAI; Araki, S.; Aryshev, A.; /KEK, Tsukuba; Bai, S.; /Beijing, Inst. High Energy Phys.; Bellomo, P.; /SLAC; Bett, D.; /Oxford U., JAI; Blair, G.; /Royal Holloway, U. of London; Bolzon, B.; /Savoie U.; Boogert, S.; Boorman, G.; /Royal Holloway, U. of London; Burrows, P.N.; Christian, G.; Coe, P.; Constance, B.; /Oxford U., JAI; Delahaye, Jean-Pierre; /CERN; Deacon, L.; /Royal Holloway, U. of London; Elsen, E.; /DESY /Valencia U., IFIC /KEK, Tsukuba /Beijing, Inst. High Energy Phys. /Savoie U. /Fermilab /Ecole Polytechnique /KEK, Tsukuba /Kyungpook Natl. U. /KEK, Tsukuba /Pohang Accelerator Lab. /Kyoto U., Inst. Chem. Res. /Savoie U. /Daresbury /Tokyo U. /Royal Holloway, U. of London /Kyungpook Natl. U. /Pohang Accelerator Lab. /Tokyo U. /KEK, Tsukuba /SLAC /University Coll. London /KEK, Tsukuba /SLAC /Royal Holloway, U. of London /KEK, Tsukuba /Tokyo U. /SLAC /Tohoku U. /KEK, Tsukuba /Tokyo U. /Pohang Accelerator Lab. /Brookhaven /SLAC /Oxford U., JAI /SLAC /Orsay /KEK, Tsukuba /Oxford U., JAI /Orsay /Fermilab /Tohoku U. /Manchester U. /CERN /SLAC /Tokyo U. /KEK, Tsukuba /Oxford U., JAI /Hiroshima U. /KEK, Tsukuba /CERN /KEK, Tsukuba /Oxford U., JAI /Ecole Polytechnique /SLAC /Oxford U., JAI /Fermilab /SLAC /Liverpool U. /SLAC /Tokyo U. /SLAC /Tokyo U. /KEK, Tsukuba /SLAC /CERN

    2011-11-11

    ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  14. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    CERN Document Server

    Bambade, P; Amann, J; Angal-Kalinin, D; Apsimon, R; Araki, S; Aryshev, A; Bai, S; Bellomo, P; Bett, D; Blair, G; Bolzon, B; Boogert, S; Boorman, G; Burrows, P N; Christian, G; Coe, P; Constance, B; Delahaye, Jean-Pierre; Deacon, L; Elsen, E; Faus-Golfe, A; Fukuda, M; Gao, J; Geffroy, N; Gianfelice-Wendt, E; Guler, H; Hayano, H; Heo, A -Y; Honda, Y; Huang, J Y; Hwang, W H; Iwashita, Y; Jeremie, A; Jones, J; Kamiya, Y; Karataev, P; Kim, E -S; Kim, H -S; Kim, S H; Komamiya, S; Kubo, K; Kume, T; Kuroda, S; Lam, B; Lyapin, A; Masuzawa, M; McCormick, D; Molloy, S; Naito, T; Nakamura, T; Nelson, J; Okamoto, D; Okugi, T; Oroku, M; Park, Y J; Parker, B; Paterson, E; Perry, C; Pivi, M; Raubenheimer, T; Renier, Y; Resta-Lopez, J; Rimbault, C; Ross, M; Sanuki, T; Scarfe, A; Schulte, D; Seryi, A; Spencer, C; Suehara, T; Sugahara, R; Swinson, C; Takahashi, T; Tauchi, T; Terunuma, N; Tomas, R; Urakawa, J; Urner, D; Verderi, M; Wang, M -H; Warden, M; Wendt, M; White, G; Wittmer, W; Wolski, A; Woodley, M; Yamaguchi, Y; Yamanaka, T; Yan, Y; Yoda, H; Yokoya, K; Zhou, F; Zimmermann, F

    2010-01-01

    ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  15. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    CERN Document Server

    Bambade, P; Amann, J; Angal-Kalinin, D; Apsimon, R; Araki, S; Aryshev, A; Bai, S; Bellomo, P; Bett, D; Blair, G; Bolzon, B; Boogert, S; Boorman, G; Burrows, P N; Christian, G; Coe, P; Constance, B; Delahaye, J P; Deacon, L; Elsen, E; Faus-Golfe, A; Fukuda, M; Gao, J; Geffroy, N; Gianfelice-Wendt, E; Guler, H; Hayano, H; Heo, A Y; Honda, Y; Huang, J Y; Hwang, W H; Iwashita, Y; Jeremie, A; Jones, J; Kamiya, Y; Karataev, P; Kim, E S; Kim, H S; Kim, S H; Komamiya, S; Kubo, K; Kume, T; Kuroda, S; Lam, B; Lyapin, A; Masuzawa, M; McCormick, D; Molloy, S; Naito, T; Nakamura, T; Nelson, J; Okamoto, D; Okugi, T; Oroku, M; Park, Y J; Parker, B; Paterson, E; Perry, C; Pivi, M; Raubenheimer, T; Renier, Y; Resta-Lopez, J; Rimbault, C; Ross, M; Sanuki, T; Scarfe, A; Schulte, D; Seryi, A; Spencer, C; Suehara, T; Sugahara, R; Swinson, C; Takahashi, T; Tauchi, T; Terunuma, N; Tomas, R; Urakawa, J; Urner, D; Verderi, M; Wang, M H; Warden, M; Wendt, M; White, G; Wittmer, W; Wolski, A; Woodley, M; Yamaguchi, Y; Yamanaka, T; Yan, Y; Yoda, H; Yokoya, K; Zhou, F; Zimmermann, F; 10.1103/PhysRevSTAB.13.042801

    2010-01-01

    ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  16. Defining the Optimal Planning Target Volume in Image-Guided Stereotactic Radiosurgery of Brain Metastases: Results of a Randomized Trial

    Energy Technology Data Exchange (ETDEWEB)

    Kirkpatrick, John P., E-mail: john.kirkpatrick@dm.duke.edu [Department of Radiation Oncology, Duke University, Durham, North Carolina (United States); Department of Surgery, Duke University, Durham, North Carolina (United States); Wang, Zhiheng [Department of Radiation Oncology, Duke University, Durham, North Carolina (United States); Sampson, John H. [Department of Radiation Oncology, Duke University, Durham, North Carolina (United States); Department of Surgery, Duke University, Durham, North Carolina (United States); McSherry, Frances; Herndon, James E. [Department of Biostatistics and Bioinformatics, Duke University, Durham, North Carolina (United States); Allen, Karen J.; Duffy, Eileen [Department of Radiation Oncology, Duke University, Durham, North Carolina (United States); Hoang, Jenny K. [Department of Radiology, Duke University, Durham, North Carolina (United States); Chang, Zheng; Yoo, David S.; Kelsey, Chris R.; Yin, Fang-Fang [Department of Radiation Oncology, Duke University, Durham, North Carolina (United States)

    2015-01-01

    Purpose: To identify an optimal margin about the gross target volume (GTV) for stereotactic radiosurgery (SRS) of brain metastases, minimizing toxicity and local recurrence. Methods and Materials: Adult patients with 1 to 3 brain metastases less than 4 cm in greatest dimension, no previous brain radiation therapy, and Karnofsky performance status (KPS) above 70 were eligible for this institutional review board–approved trial. Individual lesions were randomized to 1- or 3- mm uniform expansion of the GTV defined on contrast-enhanced magnetic resonance imaging (MRI). The resulting planning target volume (PTV) was treated to 24, 18, or 15 Gy marginal dose for maximum PTV diameters less than 2, 2 to 2.9, and 3 to 3.9 cm, respectively, using a linear accelerator–based image-guided system. The primary endpoint was local recurrence (LR). Secondary endpoints included neurocognition Mini-Mental State Examination, Trail Making Test Parts A and B, quality of life (Functional Assessment of Cancer Therapy-Brain), radionecrosis (RN), need for salvage radiation therapy, distant failure (DF) in the brain, and overall survival (OS). Results: Between February 2010 and November 2012, 49 patients with 80 brain metastases were treated. The median age was 61 years, the median KPS was 90, and the predominant histologies were non–small cell lung cancer (25 patients) and melanoma (8). Fifty-five, 19, and 6 lesions were treated to 24, 18, and 15 Gy, respectively. The PTV/GTV ratio, volume receiving 12 Gy or more, and minimum dose to PTV were significantly higher in the 3-mm group (all P<.01), and GTV was similar (P=.76). At a median follow-up time of 32.2 months, 11 patients were alive, with median OS 10.6 months. LR was observed in only 3 lesions (2 in the 1 mm group, P=.51), with 6.7% LR 12 months after SRS. Biopsy-proven RN alone was observed in 6 lesions (5 in the 3-mm group, P=.10). The 12-month DF rate was 45.7%. Three months after SRS, no significant change in

  17. Volume nanograting formation in laser-silica interaction as a result of the 1D plasma-resonance ionization instability

    CERN Document Server

    Gildenburg, V B

    2016-01-01

    The initial stage of the small-scale ionization-induced instability developing inside the fused silica volume exposed to the femtosecond laser pulse is studied as a possible initial cause of the self-organized nanograting formation. We have calculated the spatial spectra of the instability with the electron-hole diffusion taken into account for the first time and have found that it results in the formation of some hybrid (diffusion-wave) 1D structure with the spatial period determined as geometrical mean of the laser wavelength and characteristic diffusion length of the process considered. Near the threshold of the instability this period occurs to be approximately equal to the laser half-wavelength in the silica, close to the one experimentally observed.

  18. Volume nanograting formation in laser-silica interaction as a result of the 1D plasma-resonance ionization instability

    Science.gov (United States)

    Gildenburg, V. B.; Pavlichenko, I. A.

    2016-08-01

    The initial stage of the small-scale ionization-induced instability developing inside the fused silica volume exposed to the femtosecond laser pulse is studied as a possible initial cause of the self-organized nanograting formation. We have calculated the spatial spectra of the instability with the electron-hole diffusion taken into account for the first time and have found that it results in the formation of some hybrid (diffusion-wave) 1D structure with the spatial period determined as the geometrical mean of the laser wavelength and characteristic diffusion length of the process considered. Near the threshold of the instability, this period occurs to be approximately equal to the laser half-wavelength in the silica, close to the one experimentally observed.

  19. Towards the harmonization of result presentation for the eosin-5'- maleimide (EMA) binding test in the diagnosis of hereditary spherocytosis.

    Science.gov (United States)

    Hunt, Linda; Greenwood, David; Heimpel, Hermann; Noel, Nigel; Whiteway, Alastair; King, May-Jean

    2014-09-01

    Background: The EMA Binding test measures reduced mean channel fluorescence (MCF) reading of EMA-labeled red cells (EMA-RBCs) from patients with hereditary spherocytosis (HS). Reporting test results can be either in the actual MCF reading or as a ratio by normalization of the test MCF result to the mean MCF value of 6 normal controls. The latter format has potential for universal reporting. Methods: We analyzed three years' archival MCF data from HS and non-HS patient groups for establishment of reference ranges of ratios for normal adults and HS. A prospective study used FC500 and FACS Canto II cytometers to analyze contemporaneously EMA-RBCs from several patient groups and normal donors. Statistical analyses of the prospective data determined the cut-off values, and the sensitivity and specificity for HS respectively for the MCF and the ratio result presentations. The effect of using fewer than six normal controls for the ratio denominator was explored. Results:. The FC500 gave a mean ratio of 0.782 (SD = 0.086) in HS patients with an optimal cut-off ratio of 0.918 (98.7% specificity, 95.6% sensitivity), and grey area ratio of 0.868 - 0.918. The Canto II gave a mean ratio of 0.774 (SD = 0.085) with an optimal cut-off ratio of 0.925 (97.1% specificity and 100% sensitivity), and grey area ratio of 0.859 - 0.925. Conclusion: Harmonization of result presentation is feasible with no apparent constraint by instrument design. Interpretation of grey-area data requires an assessment of patient's clinical presentation and family history or performing a family study. © 2014 Clinical Cytometry Society.

  20. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    Directory of Open Access Journals (Sweden)

    2010-04-01

    Full Text Available ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  1. Application and evaluation of interactive 3D PDF for presenting and sharing planning results for liver surgery in clinical routine.

    Science.gov (United States)

    Newe, Axel; Becker, Linda; Schenk, Andrea

    2014-01-01

    The Portable Document Format (PDF) is the de-facto standard for the exchange of electronic documents. It is platform-independent, suitable for the exchange of medical data, and allows for the embedding of three-dimensional (3D) surface mesh models. In this article, we present the first clinical routine application of interactive 3D surface mesh models which have been integrated into PDF files for the presentation and the exchange of Computer Assisted Surgery Planning (CASP) results in liver surgery. We aimed to prove the feasibility of applying 3D PDF in medical reporting and investigated the user experience with this new technology. We developed an interactive 3D PDF report document format and implemented a software tool to create these reports automatically. After more than 1000 liver CASP cases that have been reported in clinical routine using our 3D PDF report, an international user survey was carried out online to evaluate the user experience. Our solution enables the user to interactively explore the anatomical configuration and to have different analyses and various resection proposals displayed within a 3D PDF document covering only a single page that acts more like a software application than like a typical PDF file ("PDF App"). The new 3D PDF report offers many advantages over the previous solutions. According to the results of the online survey, the users have assessed the pragmatic quality (functionality, usability, perspicuity, efficiency) as well as the hedonic quality (attractiveness, novelty) very positively. The usage of 3D PDF for reporting and sharing CASP results is feasible and well accepted by the target audience. Using interactive PDF with embedded 3D models is an enabler for presenting and exchanging complex medical information in an easy and platform-independent way. Medical staff as well as patients can benefit from the possibilities provided by 3D PDF. Our results open the door for a wider use of this new technology, since the basic idea

  2. Can elevated lactate and LDH produce a false positive enzymatic ethanol result in live patients presenting to the emergency department?

    Science.gov (United States)

    Nacca, Nicholas; Hodgman, Michael J; Lao, Kirselle; Elkins, Matthew; Holland, Michael G

    2017-08-16

    There have been allegations in the courtroom that elevated serum lactic acid in trauma victims can yield a falsely elevated serum ethanol assay. Most hospitals utilize an indirect method of ethanol measurement where a serum sample is added to a mix of alcohol dehydrogenase and oxidized nicotinamide adenine dinucleotide (NAD+). This allows any ethanol in the patient's serum to be metabolized to acetaldehyde, and in the process results in the reduction of NAD + to NADH. NADH is then measured using spectrophotometry. The courtroom allegation stems from the concept that oxidation of lactate to pyruvate by lactate dehydrogenase (LDH) results in the same molar-for-molar reduction of NAD + to NADH, and could therefore theoretically cause patients with elevated lactate and LDH to have a falsely elevated ethanol concentration. Patients with elevated lactic acid and LDH concentrations who presented to a university hospital from 20 April 2015 to 13 December 2015 were identified to provide possible test specimens. If a sufficient amount of serum was available, the sample was used to re-run the lactate and LDH concentration simultaneously with an enzymatic ethanol assay. Any samples that had elevated lactic acid and LDH concentrations on this retesting, and also yielded a positive ethanol concentration, were sent for confirmatory gas chromatography testing of ethanol concentrations. A control group of 20 samples with normal lactate and LDH were included. A total of 37 samples were included in the final analysis. Only 4 patients had an elevated enzymatic ethanol concentration, and all 4 also had a measurable GC ethanol concentration. The lactate in this dataset ranged from 2.4 to 24.2 mmol/L, with a mean of 6.53 mmol/L (normal value 0.5-2.2). The LDH ranged from 242 to 8838 U/L with a mean of 1695 U/L (normal value 122-225 U/L). Twenty control samples were run on patients with normal lactate and LDH, none of which yielded a positive enzymatic ethanol result

  3. Hypo - and hypernatremia results in inaccurate Erythrocytes mean Corpuscular Volume (MCV) measurement in vitro, when using Sysmex XE 2100

    DEFF Research Database (Denmark)

    Madsen, Kirsten Vikkelsø; Philipsen, Jens Peter

    2015-01-01

    Introduction: Automated hematology analyzers dilute patient erythrocytes with an isosmotic diluent before quantitating the erythrocyte Mean Cell Volume (MCV). However, if patient plasma osmolality differs from the diluent, water will cross the erythrocytes membrane and establish a new equilibrium...

  4. The WELSONS experiment: overview and presentation of first results on the surface atmospheric boundary-layer in semiarid Spain

    Directory of Open Access Journals (Sweden)

    J.-P. Frangi

    Full Text Available This study presents the preliminary results of the local energy budget and dynamic characteristics of the surface atmospheric boundary-layer (SBL during the WELSONS (wind erosion and losses of soil nutrients in semiarid Spain experiment. Some Mediterranean regions suffer land degradation by wind erosion as a consequence of their particular soil and climate conditions and inappropriate agricultural practice. In Spain, where land degradation by water erosion is well known, the lack of field studies to quantify soils losses by wind erosion resulted in the European Community organizing a scientific program for this specific issue. The European programme known as WELSONS was devoted to study the wind erosion process in central Aragon (NE Spain. This multidisciplinary experiment, which began in 1996 and finished in 1998, was carried out over an agricultural soil which was left fallow. Within the experimental field, two plots were delimited where two tillage treatments were applied, a mould-board ploughing (or conventional tillage denoted CT and chisel ploughing (reduced tillage denoted RT. This was to study on bare soil the influence of tillage method on surface conditions, saltation flux, vertical dust flux, erosion rates, dynamics characteristics such as friction velocity, roughness length, etc., and energy budget. The partitioning of the available energy, resulting from the dynamics of the SBL, are quite different over the two plots because of their own peculiar soil and surface properties. The first results show that the RT treatment seems to provide a wind erosion protection. Because of the long data recording time and particular phenomena (formation of a crust at the soil surface, very dry conditions, high wind speed for instance, these microclimatological data acquired during the WELSONS programmes may be helpful to test atmospheric boundary-layer models coupled with soil models.

    Key words: Hydrology (desertification - Meterology and

  5. Yoga Meditation Practitioners Exhibit Greater Gray Matter Volume and Fewer Reported Cognitive Failures: Results of a Preliminary Voxel-Based Morphometric Analysis

    Directory of Open Access Journals (Sweden)

    Brett Froeliger

    2012-01-01

    Full Text Available Hatha yoga techniques, including physical postures (asanas, breathing exercises (pranayama, and meditation, involve the practice of mindfulness. In turn, yoga meditation practices may induce the state of mindfulness, which, when evoked recurrently through repeated practice, may accrue into trait or dispositional mindfulness. Putatively, these changes may be mediated by experience-dependent neuroplastic changes. Though prior studies have identified differences in gray matter volume (GMV between long-term mindfulness practitioners and controls, no studies to date have reported on whether yoga meditation is associated with GMV differences. The present study investigated GMV differences between yoga meditation practitioners (YMP and a matched control group (CG. The YMP group exhibited greater GM volume in frontal, limbic, temporal, occipital, and cerebellar regions; whereas the CG had no greater regional greater GMV. In addition, the YMP group reported significantly fewer cognitive failures on the Cognitive Failures Questionnaire (CFQ, the magnitude of which was positively correlated with GMV in numerous regions identified in the primary analysis. Lastly, GMV was positively correlated with the duration of yoga practice. Results from this preliminary study suggest that hatha yoga practice may be associated with the promotion of neuroplastic changes in executive brain systems, which may confer therapeutic benefits that accrue with repeated practice.

  6. [An evaluation of sampling design for estimating an epidemiologic volume of diabetes and for assessing present status of its control in Korea].

    Science.gov (United States)

    Lee, Ji-Sung; Kim, Jaiyong; Baik, Sei-Hyun; Park, Ie-Byung; Lee, Juneyoung

    2009-03-01

    An appropriate sampling strategy for estimating an epidemiologic volume of diabetes has been evaluated through a simulation. We analyzed about 250 million medical insurance claims data submitted to the Health Insurance Review & Assessment Service with diabetes as principal or subsequent diagnoses, more than or equal to once per year, in 2003. The database was re-constructed to a 'patient-hospital profile' that had 3,676,164 cases, and then to a 'patient profile' that consisted of 2,412,082 observations. The patient profile data was then used to test the validity of a proposed sampling frame and methods of sampling to develop diabetic-related epidemiologic indices. Simulation study showed that a use of a stratified two-stage cluster sampling design with a total sample size of 4,000 will provide an estimate of 57.04% (95% prediction range, 49.83 - 64.24%) for a treatment prescription rate of diabetes. The proposed sampling design consists, at first, stratifying the area of the nation into "metropolitan/city/county" and the types of hospital into "tertiary/secondary/primary/clinic" with a proportion of 5:10:10:75. Hospitals were then randomly selected within the strata as a primary sampling unit, followed by a random selection of patients within the hospitals as a secondly sampling unit. The difference between the estimate and the parameter value was projected to be less than 0.3%. The sampling scheme proposed will be applied to a subsequent nationwide field survey not only for estimating the epidemiologic volume of diabetes but also for assessing the present status of nationwide diabetes control.

  7. Clustered granules present in the hippocampus of aged mice result from a degenerative process affecting astrocytes and their surrounding neuropil.

    Science.gov (United States)

    Manich, Gemma; Cabezón, Itsaso; Camins, Antoni; Pallàs, Mercè; Liberski, Pawel P; Vilaplana, Jordi; Pelegrí, Carme

    2014-01-01

    Clusters of pathological granular structures appear and progressively increase in number with age in the hippocampus of several mice strains, markedly in the senescence-accelerated mouse prone 8 mice. In the present work, we performed an ultrastructural study of these granules paying special attention to the first stages of their formation, which have not been previously explored. The analysis of the immature granules allowed concluding that granules are not simple accumulations of molecular waste but the result of a degenerative process involving principally astrocytic processes, although nearby neuronal structures can be also affected. The granule generation includes the instability of the plasmatic membranes and the appearance of abnormal membranous structures that form intracellular bubbles or blebs of variable sizes and irregular shapes. These structures and some organelles degenerate producing some membranous fragments, and an assembly process of the resulting fragments generates the dense-core nucleus of the mature granule. Moreover, we found out that the neo-epitope recently described in the mature granules and localised abundantly in the membranous fragments of their dense-core nucleus emerges in the first stages of the granule formation. On the other hand, with this study, we increase the evidences that each cluster of granules is formed by the granules comprised in one astrocyte. A better knowledge of the causes of the granule formation and the function of the neo-epitope will help in both the interpretation of the physiological significance of the granules and their contribution to the degenerating processes in aging brain.

  8. KMWin--a convenient tool for graphical presentation of results from Kaplan-Meier survival time analysis.

    Directory of Open Access Journals (Sweden)

    Arnd Gross

    Full Text Available BACKGROUND: Analysis of clinical studies often necessitates multiple graphical representations of the results. Many professional software packages are available for this purpose. Most packages are either only commercially available or hard to use especially if one aims to generate or customize a huge number of similar graphical outputs. We developed a new, freely available software tool called KMWin (Kaplan-Meier for Windows facilitating Kaplan-Meier survival time analysis. KMWin is based on the statistical software environment R and provides an easy to use graphical interface. Survival time data can be supplied as SPSS (sav, SAS export (xpt or text file (dat, which is also a common export format of other applications such as Excel. Figures can directly be exported in any graphical file format supported by R. RESULTS: On the basis of a working example, we demonstrate how to use KMWin and present its main functions. We show how to control the interface, customize the graphical output, and analyse survival time data. A number of comparisons are performed between KMWin and SPSS regarding graphical output, statistical output, data management and development. Although the general functionality of SPSS is larger, KMWin comprises a number of features useful for survival time analysis in clinical trials and other applications. These are for example number of cases and number of cases under risk within the figure or provision of a queue system for repetitive analyses of updated data sets. Moreover, major adjustments of graphical settings can be performed easily on a single window. CONCLUSIONS: We conclude that our tool is well suited and convenient for repetitive analyses of survival time data. It can be used by non-statisticians and provides often used functions as well as functions which are not supplied by standard software packages. The software is routinely applied in several clinical study groups.

  9. Results of Second Outdoor Comparison Between Absolute Cavity Pyrgeometer (ACP) and Infrared Integrating Sphere (IRIS) Radiometer at PMOD (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Reda, I.; Grobner, J.; Wacker, S.

    2014-01-01

    The Absolute Cavity Pyrgeometer (ACP) and InfraRed Integrating Sphere radiometer (IRIS) are developed to establish a world reference for calibrating pyrgeometers with traceability to SI units. The two radiometers are un-windowed with negligible spectral dependence, and traceable to SI units through the temperature scale (ITS-90). The second outdoor comparison between the two designs was held from September 30 to October 11, 2013 at the Physikalisch-Metorologisches Observatorium Davos (PMOD). The difference between the irradiance measured by ACP and that of the IRIS was within 1 W/m2 (3 IRISs: PMOD + Australia + Germany). From the first and second comparisons, a difference of 4-6 W/m2 was observed between the irradiance measured by ACP&IRIS and that of the interim World Infrared Standard Group (WISG). This presentation includes results from the first and second comparison in an effort to establish the world reference for pyrgeometer calibrations, a key deliverable for the World Meteorological Organization (WMO), and the DOE-ASR.

  10. INDICATOR AND PATHOGENIC MICROORGANISMS CONTAMINATION OF HIDE OF CATTLE PRESENTED TO FOR SLAUGHTER AND CONTAMINATION OF THE RESULTANT CARCASSES

    Directory of Open Access Journals (Sweden)

    G. Liuzzo

    2011-01-01

    Full Text Available Foodborne pathogens including Escherichia coli O157:H7, Salmonella spp. and Campylobacter spp., can enter the meat chain at multiple points. Animals with excessively dirty hides will represent a risk of cross-contaminations during transport, in the slaughtered house environment and during dressing procedures. The aim of this work was to investigate the relationship among hygiene indicator microorganisms (Enterobacteriaceae and Escherichia coli count, in hide and carcass of cattle presented for slaughter, and different hide cleanliness level in two abattoir (R and F and estimate the prevalence of pathogens Escherichia coli O157:H7, Salmonella spp and Campylobacter spp. in hide and carcass of dirty animals. The results showed that hide Escherichia coli and Enterobacteriaceae count were significantly higher in dirty animals than in clean animals (P<0,05, but carcass contamination were significantly higher in dirty animals than in clean animals only in R abattoir. Escherichia coli O 157:H7 was detected in 19 samples of hide (40,4%, and 2 samples of carcass. Campylobacter jejuni was isolated in 13 samples of hide (25,5% and one sample of carcass. Salmonella spp. were not found in all the samples of hide and carcass.

  11. SU-C-210-06: Quantitative Evaluation of Dosimetric Effects Resulting From Positional Variations of Pancreatic Tumor Volumes

    Energy Technology Data Exchange (ETDEWEB)

    Yu, S; Sehgal, V; Wei, R; Lawrenson, L; Kuo, J; Hanna, N; Ramsinghani, N; Daroui, P; Al-Ghazi, M [University of California, Orange, CA (United States)

    2015-06-15

    Purpose: The aim of this study is to quantify dosimetric effects resulting from variation in pancreatic tumor position assessed by bony anatomy and implanted fiducial markers Methods: Twelve pancreatic cancer patients were retrospectively analyzed for this study. All patients received modulated arc therapy (VMAT) treatment using fiducial-based Image Guided Radiation Therapy (IGRT) to the intact pancreas. Using daily orthogonal kV and/or Cone beam CT images, the shift needed to co-register the daily pre-treatment images to reference CT from fiducial to bone (Fid-Bone) were recorded as Left-Right (LR), Anterior-Posterior (AP) and Superior-Inferior (SI). The original VMAT plan iso-center was shifted based on KV bone matching positions at 5 evenly spaced fractions. Dose coverage of the planning target volumes (PTVs) (V100%), mean dose to liver, kidney and stomach/duodenum were assessed in the modified plans. Results: A total of 306 fractions were analyzed. The absolute fiducial-bone positional shifts were greatest in the SI direction, (AP = 2.7 ± 3.0, LR = 2.8 ± 2.8, and SI 6.3 ± 7.9 mm, mean ± SD). The V100% was significantly reduced by 13.5%, (Fid-Bone = 95.3 ± 2.0 vs. 82.3 ± 11.8%, p=0.02). This varied widely among patients (Fid-Bone V100% Range = 2–60%), where 33% of patients had a reduction in V100% of more than 10%. The impact on OARs was greatest to the liver (Fid-Bone= 14.6 vs. 16.1 Gy, 10%), and stomach, (Fid-Bone = 23.9 vx. 25.5 Gy, 7%), however was not statistically significant (p=0.10 both). Conclusion: Compared to matching by fiducial markers, matching by bony anatomy would have substantially reduced the PTV coverage by 13.5%. This reinforces the importance of online position verification based on fiducial markers. Hence, implantation of fiducial markers is strongly recommended for pancreatic cancer patients undergoing intensity modulated radiation therapy treatments.

  12. DOT/NASA comparative assessment of Brayton engines for guideway vehicles and busses. Volume 2: Analysis and results

    Science.gov (United States)

    1975-01-01

    Gas turbine engines were assessed for application to hear duty transportation. A summary of the assumptions, applications, and methods of analysis is included along with a discussion of the approach taken, the technical program flow chart, and weighting criteria used for performance evaluation. The various engines are compared on the bases of weight, performance, emissions and noise, technology status, and growth potential. The results of the engine screening phase and the conceptual design phase are presented.

  13. Field Test Results of Using a Nacelle-Mounted Lidar for Improving Wind Energy Capture by Reducing Yaw Misalignment (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, P.; Scholbrock, A.; Wright, A.

    2014-11-01

    Presented at the Nordic Wind Power Conference on November 5, 2014. This presentation describes field-test campaigns performed at the National Wind Technology Center in which lidar technology was used to improve the yaw alignment of the Controls Advanced Research Turbine (CART) 2 and CART3 wind turbines. The campaigns demonstrated that whether by learning a correction function to the nacelle vane, or by controlling yaw directly with the lidar signal, a significant improvement in power capture was demonstrated.

  14. "Prevalence of Thyrotoxicosis: Clinical presentation and results of treatment in 384 patients with Goiter under 18 years "

    Directory of Open Access Journals (Sweden)

    "Moayeri H

    2002-08-01

    Full Text Available Goiter is common among growing children and adolescents but thyrotoxicosis is a rare thyroid disorder in this age prevalence of thyrotoxicosis and clinical presentation in prevalence of thyrotoxicosis and clinical presentation of the disease among children and adolescents of the disease among children and adolescents presenting for goiter at the clinics of pediatric presenting for goiter at the clinics of pediatric Endocrinology of Tehran and Iran University of medical sciences and private offices. In a retrospective study the medical records of 424 patients with goiter were studied of whom 384 (285F, 99M and goiter and records available for review. All patients were examined by pediatric endocrinologist and their goiters were classified according to WHO criteria. Total T4, TSH, T3 and T3RU were measured. Out of the 384 cases that were diagnosed as goiter, 320 were euthyroid (83.4%, 49 were hypothyroid (12.7% and 15 were hyperthyroid (3.9%. Ninety-three percent of the hyperthyroid patients had graves’ disease and seven percent of them had toxic adenoma. The most common presenting feature in thyrotoxic patients was goiter. Sustained remission with medical treatment alone was attained in 46% with a mean treatment duration of 2.9 years. The comparison was made between the findings of this study and those of western countries indicating that the incidence of hyperthyroidism in Iranian pediatric population is not as high as in North America but is higher than in Europe. Clinical presentation, response to treatment and etiologic causes of the disease in our study was similar to other studies.

  15. Sensitivity of volumetric modulated arc therapy patient specific QA results to multileaf collimator errors and correlation to dose volume histogram based metrics.

    LENUS (Irish Health Repository)

    Coleman, Linda

    2013-11-01

    This study investigates the impact of systematic multileaf collimator (MLC) positional errors on gamma analysis results used for quality assurance (QA) of Rapidarc treatments. In addition, this study evaluates the relationship of these gamma analysis results and clinical dose volume histogram metrics (DVH) for Rapidarc treatment plans.

  16. Alpha-1-antitrypsin deficiency resulting in a hitherto unseen presentation of hepatocellular carcinoma: Polycythemia but with normal alpha fetoprotein

    Institute of Scientific and Technical Information of China (English)

    David Ryan Owen; Ramachandran Sivakumar; Eui-Sik Suh; Murugiah Seevaratnam

    2006-01-01

    Polycythemia is a known paraneopastic manifestation of hepatoma, but only in the presence of alpha-fetopro (AFP). We present a case of polycythemia in the absence of AFP, and suggest concurrent alpha-1-antitrypsin deficiency as the cause for breaking this rule. We also suggest a reason for the apparent constant conjunction between polycythemia and AFP in hepatoma.

  17. Debris-flow monitoring at the Rebaixader torrent, Central Pyrenees, Spain: results on initiation, volume and dynamic behaviour

    OpenAIRE

    Hurlimann Ziegler, Marcel; Abancó, Clàudia; Moya Sánchez, José

    2014-01-01

    The sophisticated monitoring system installed in the Rebaixader catchment incorporates a total of 6 different stations: four stations recording information on the initiation mechanisms (two meteorological stations and two infiltration stations), and two stations focussing on the debris flow detection and the dynamic behaviour of the flows. Between August 2009 and August 2013, seven debris flows and seventeen debris floods were detected. The volumes of the debris flows ranged from 2,100 to 16,...

  18. Quantum-Mechanical QSPR Models for Polymerization Volume Change of Epoxides and Methacrylates Based on Mercury Dilatometry Results

    OpenAIRE

    Miller, Matthew D.; Holder, Andrew J.; Kilway, Kathleen V.; Giese, Gregory J.; Finley, Jason E.; Travis, DeAnna M.; Iwai, Benjamin T.; Eick, J. David

    2006-01-01

    Polymerization volume change (PVC) was measured systematically using mercury dilatometry for 41 epoxide and methacrylate monomers with quartz filler. Quantitative structure property relationship (QSPR) models were developed based on this previously unreported data to gain insight in the data collection method for future models. Successful models included only data from those samples which polymerized to hardness. The most significant descriptors in these models related to monomer reactivity. ...

  19. Neutrophil volume, conductivity and scatter parameters with effective modeling of molecular activity statistical program gives better results in neonatal sepsis.

    Science.gov (United States)

    Celik, I H; Demirel, G; Sukhachev, D; Erdeve, O; Dilmen, U

    2013-02-01

    Neonatal sepsis remains an important clinical syndrome despite advances in neonatology. Current hematology analyzers can determine cell volume (V), conductivity for internal composition of cell (C) and light scatter for cytoplasmic granularity and nuclear structure (S), and standard deviations which are effective in the diagnosis of sepsis. Statistical models can be used to strengthen the diagnosis. Effective modeling of molecular activity (EMMA) uses combinatorial algorithm of the selection parameters for regression equation based on modified stepwise procedure. It allows obtaining different regression models with different combinations of parameters. We investigated these parameters in screening of neonatal sepsis. We used LH780 hematological analyzer (Beckman Coulter, Fullerton, CA, USA). We combined these parameters with interleukin-6 (IL-6) and C-reactive protein (CRP) and developed models by EMMA. A total of 304 newborns, 76 proven sepsis, 130 clinical sepsis and 98 controls, were enrolled in the study. Mean neutrophil volume (MNV) and volume distribution width (VDW) were higher in both proven and clinical sepsis groups. We developed three models using MNV, VDW, IL-6, and CRP. These models gave more sensitivity and specificity than the usage of each marker alone. We suggest to use the combination of MNV and VDW with markers such as CRP and IL-6, and use diagnostic models created by EMMA. © 2012 Blackwell Publishing Ltd.

  20. Childhood sarcoidosis in Denmark 1979-1994: incidence, clinical features and laboratory results at presentation in 48 children

    DEFF Research Database (Denmark)

    Hoffmann, A L; Milman, N; Byg, K E

    2004-01-01

    and central nervous system symptoms were common; 31% of patients had erythema nodosum, 12.5% sarcoid skin lesions, 25% uveitis/iridocyclitis and 4.2% sarcoid arthritis. Chest X-rays were normal (stage 0) in 10% of patients, and showed pulmonary infiltrates stage I in 71%, stage II in 8.3% and stage III in 8...... examination (glucose, albumin, haemoglobin) was normal in 96% of the patients; the patient with nephrocalcinosis had albuminuria and haematuria. CONCLUSION: The incidence of sarcoidosis in Danish children is low and increases with age. Sarcoidosis in young children may present clinical features...... that are different from the appearance of those in older children and often constitute a diagnostic challenge. In older children, the clinical appearance has many features in common with the presentation in adults....

  1. Delayed Presentation of Isolated Complete Pancreatic Transection as a Result of Sport-Related Blunt Trauma to the Abdomen

    Directory of Open Access Journals (Sweden)

    Andrew J. Healey

    2008-01-01

    Full Text Available Introduction: Blunt abdominal trauma is a rare but well-recognized cause of pancreatic transection. A delayed presentation of pancreatic fracture following sport-related blunt trauma with the coexisting diagnostic pitfalls is presented. Case Report: A 17-year-old rugby player was referred to our specialist unit after having been diagnosed with traumatic pancreatic transection, having presented 24 h after a sporting injury. Despite haemodynamic stability, at laparotomy he was found to have a diffuse mesenteric hematoma involving the large and small bowel mesentery, extending down to the sigmoid colon from the splenic flexure, and a large retroperitoneal hematoma arising from the pancreas. The pancreas was completely severed with the superior border of the distal segment remaining attached to the splenic vein that was intact. A distal pancreatectomy with spleen preservation and evacuation of the retroperitoneal hematoma was performed. Discussion/Conclusion: Blunt pancreatic trauma is a serious condition. Diagnosis and treatment may often be delayed, which in turn may drastically increase morbidity and mortality. Diagnostic difficulties apply to both paraclinical and radiological diagnostic methods. A high index of suspicion should be maintained in such cases, with a multi-modality diagnostic approach and prompt surgical intervention as required.

  2. Interobserver variability in gross tumor volume delineation for hepatocellular carcinoma. Results of Korean Radiation Oncology Group 1207 study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Suk [Jeju National University School of Medicine, Department of Radiation Oncology, Jeju National University Hospital, Jeju (Korea, Republic of); Kim, Jun Won; Lee, Ik Jae [Yonsei University College of Medicine, Department of Radiation Oncology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Yoon, Won Sup [Korea University Medical Center, Department of Radiation Oncology, Ansan Hospital, Ansan (Korea, Republic of); Kang, Min Kyu [Kyungpook National University School of Medicine, Department of Radiation Oncology, Daegu (Korea, Republic of); Kim, Tae Hyun [National Cancer Center, Center for Liver Cancer, Goyang (Korea, Republic of); Kim, Jin Hee [Keimyung University School of Medicine, Department of Radiation Oncology, Dongsan Medical Center, Daegu (Korea, Republic of); Lee, Hyung-Sik [Dong-A University College of Medicine, Department of Radiation Oncology, Busan (Korea, Republic of); Park, Hee Chul [Sungkyunkwan University School of Medicine, Department of Radiation Oncology, Samsung Medical Center, Seoul (Korea, Republic of); Jang, Hong Seok; Kay, Chul Seung [The Catholic University of Korea College of Medicine, Department of Radiation Oncology, Seoul (Korea, Republic of); Yoon, Sang Min [University of Ulsan College of Medicine, Department of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of); Kim, Mi-Sook [Korea Institute of Radiological and Medical Sciences, Department of Radiation Oncology, Seoul (Korea, Republic of); Seong, Jinsil [Yonsei University College of Medicine, Department of Radiation Oncology, Severance Hospital, Seodaemun-gu, Seoul (Korea, Republic of)

    2016-10-15

    There has been increasing use of external beam radiotherapy for localized treatment of hepatocellular carcinoma (HCC) with both palliative and curative intent. Quality control of target delineation in primary HCC is essential to deliver adequate doses of radiation to the primary tumor while preserving adjacent healthy organs. We analyzed interobserver variability in gross tumor volume (GTV) delineation for HCC. Twelve radiation oncologists specializing in liver malignancy participated in a multi-institutional contouring dummy-run study of nine HCC cases and independently delineated GTV on the same set of provided computed tomography images. Quantitative analysis was performed using an expectation maximization algorithm for simultaneous truth and performance level estimation (STAPLE) with kappa statistics calculating agreement between physicians. To quantify the interobserver variability of GTV delineations, the ratio of the actual delineated volume to the estimated consensus volume (STAPLE), the ratio of the common and encompassing volumes, and the coefficient of variation were calculated. The median kappa agreement level was 0.71 (range 0.28-0.86). The ratio of the actual delineated volume to the estimated consensus volume ranged from 0.19 to 1.93 (median 0.94) for all cases. The ratio of the common and encompassing volumes ranged from 0.001 to 0.56 (median 0.25). The coefficient of variation for GTV delineation ranged from 8 to 57 % (median 26 %). The interobserver variability in target delineation of HCC GTV in this study is noteworthy. Multi-institution studies involving radiotherapy for HCC require appropriate quality assurance programs for target delineation. (orig.) [German] Die externe kurative Strahlentherapie ist zunehmend bei der lokalisierten Behandlung hepatozellulaerer Karzinome (HCC) in palliativer und kurativer Absicht in Gebrauch. Eine Qualitaetskontrolle der Zielabgrenzung beim primaeren HCC ist entscheidend, um die passende Dosis fuer die

  3. The albatross plot: A novel graphical tool for presenting results of diversely reported studies in a systematic review.

    Science.gov (United States)

    Harrison, Sean; Jones, Hayley E; Martin, Richard M; Lewis, Sarah J; Higgins, Julian P T

    2017-09-01

    Meta-analyses combine the results of multiple studies of a common question. Approaches based on effect size estimates from each study are generally regarded as the most informative. However, these methods can only be used if comparable effect sizes can be computed from each study, and this may not be the case due to variation in how the studies were done or limitations in how their results were reported. Other methods, such as vote counting, are then used to summarize the results of these studies, but most of these methods are limited in that they do not provide any indication of the magnitude of effect. We propose a novel plot, the albatross plot, which requires only a 1-sided P value and a total sample size from each study (or equivalently a 2-sided P value, direction of effect and total sample size). The plot allows an approximate examination of underlying effect sizes and the potential to identify sources of heterogeneity across studies. This is achieved by drawing contours showing the range of effect sizes that might lead to each P value for given sample sizes, under simple study designs. We provide examples of albatross plots using data from previous meta-analyses, allowing for comparison of results, and an example from when a meta-analysis was not possible. Copyright © 2017 The Authors. Research Synthesis Methods Published by John Wiley & Sons Ltd.

  4. Does {sup 131}I-treatment of goitre result in an acute increase in the volume a function of the thyroid gland?; Medfoerer {sup 131}I-behandling af strufma en akut foroegelse af glandula thyreoideas volumen og funktion?

    Energy Technology Data Exchange (ETDEWEB)

    Nygaard, B.; Faber, J.O.; Hegedues, L.

    1995-12-01

    Many textbooks claim that radioiodine ({sup 131}I) treatment should be avoided in treatment of a goitre with substernal extension, due to fear of acute swelling of the gland with resulting respiratory problems. We examined patients with multinodular goitre, either nontoxic (n=20) or toxic (n=10) after treatment with {sup 131}I. An ultrasonically determined thyroid volume and thyroid function variables were investigated before and two, seven, 14, 21, 28 and 35 days after treatment. In nontoxic goitres the thyroid volume did not increase significantly, the maximum increase in the median volume being 4% on day 7. Serum levels of free T{sub 3} and free T{sub 4} indices increased by 20% (day 7) and 13% (day 14) (p=0.002), respectively. Likewise thyroid volume in toxic nodular goitre did not change significantly after {sup 131}I treatment. None of the patients presented symptoms of tracheal compression. We conclude that {sup 131}I treatment of nontoxic as well as toxic multinodular goitre does not seem to increase thyroid volume. (au) 18 refs.

  5. Computer-generated vs. physician-documented history of present illness (HPI): results of a blinded comparison.

    Science.gov (United States)

    Almario, Christopher V; Chey, William; Kaung, Aung; Whitman, Cynthia; Fuller, Garth; Reid, Mark; Nguyen, Ken; Bolus, Roger; Dennis, Buddy; Encarnacion, Rey; Martinez, Bibiana; Talley, Jennifer; Modi, Rushaba; Agarwal, Nikhil; Lee, Aaron; Kubomoto, Scott; Sharma, Gobind; Bolus, Sally; Chang, Lin; Spiegel, Brennan M R

    2015-01-01

    Healthcare delivery now mandates shorter visits with higher documentation requirements, undermining the patient-provider interaction. To improve clinic visit efficiency, we developed a patient-provider portal that systematically collects patient symptoms using a computer algorithm called Automated Evaluation of Gastrointestinal Symptoms (AEGIS). AEGIS also automatically "translates" the patient report into a full narrative history of present illness (HPI). We aimed to compare the quality of computer-generated vs. physician-documented HPIs. We performed a cross-sectional study with a paired sample design among individuals visiting outpatient adult gastrointestinal (GI) clinics for evaluation of active GI symptoms. Participants first underwent usual care and then subsequently completed AEGIS. Each individual thereby had both a physician-documented and a computer-generated HPI. Forty-eight blinded physicians assessed HPI quality across six domains using 5-point scales: (i) overall impression, (ii) thoroughness, (iii) usefulness, (iv) organization, (v) succinctness, and (vi) comprehensibility. We compared HPI scores within patient using a repeated measures model. Seventy-five patients had both computer-generated and physician-documented HPIs. The mean overall impression score for computer-generated HPIs was higher than physician HPIs (3.68 vs. 2.80; PComputer-generated HPIs were also judged more complete (3.70 vs. 2.73; PComputer-generated HPIs were of higher overall quality, better organized, and more succinct, comprehensible, complete, and useful compared with HPIs written by physicians during usual care in GI clinics.

  6. Analysis of air-toxics emissions, exposures, cancer risks and controllability in five urban areas. Volume 2. Controllability analysis and results

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, J.; Coleman, B.; Laich, E.; Powell, R.

    1990-04-01

    The report (Volume 2) is the second phase of a study to define the urban air toxics problem and to discern what combination of control measures can best be employed to mitigate the problem. Volume 1 of the study documented the base year analysis (nominally the year 1980), involving dispersion modeling of emissions data for 25 carcinogenic air toxics in five U.S. urban areas and a subsequent assessment of estimated aggregate cancer incidence. The Volume 2 report applies various control strategies and analyzes the resulting reduction in aggregate cancer incidence that would occur between 1980 and 1995. Control scenarios consisted of (1) efforts that were currently underway to reduce air toxics emissions at the time of the study, (2) efforts that were expected to occur by 1995, mainly national standards that were under development, and (3) a series of selected more rigorous controls.

  7. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Summary of results. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Whitehead, D.W. [ed.; Staple, B.D.; Daniel, S.L. [and others

    1995-07-01

    During 1989 the Nuclear Regulatory Commission (NRC) initiated an extensive program to examine the potential risks during low power and shutdown operations. Two plants, Surry and Grand Gulf, were selected as the plants to be studied by Brookhaven National Laboratory (Surry) and Sandia National Laboratories (Grand Gulf). This report documents the work performed during the analysis of the Grand Gulf plant. A phased approach was used for the overall study. In Phase 1, the objectives were to identify potential vulnerable plant configurations, to characterize (on a high, medium, or low basis) the potential core damage accident scenario frequencies and risks, and to provide a foundation for a detailed Phase 2 analysis. It was in Phase 1 that the concept of plant operational states (POSs) was developed to allow the analysts to better represent the plant as it transitions from power operation to nonpower operation than was possible with the traditional technical specification divisions of modes of operation. This phase consisted of a coarse screening analysis performed for all POSs, including seismic and internal fire and flood for some POSs. In Phase 2, POS 5 (approximately cold shutdown as defined by Grand Gulf Technical Specifications) during a refueling outage was selected as the plant configuration to be analyzed based on the results of the Phase 1 study. The scope of the Level 1 study includes plant damage state analysis and uncertainty analysis and is documented in a multi-volume NUREG/CR report (i.e., NUREG/CR-6143). The internal events analysis is documented in Volume 2. Internal fire and internal flood analyses are documented in Volumes 3 and 4, respectively. A separate study on seismic analysis, documented in Volume 5, was performed for the NRC by Future Resources Associates, Inc. The Level 2/3 study of the traditional internal events is documented in Volume 6, and a summary of the results for all analyses is documented in Volume 1.

  8. Why are Wischnewski spots not always present in lethal hypothermia? The results of testing a stress-reduced animal model.

    Science.gov (United States)

    Bright, Fiona; Winskog, Calle; Walker, Melissa; Byard, Roger W

    2013-08-01

    Hypothermic fatalities in humans are characterized by a range of often subtle pathological findings that typically include superficial erosive gastritis (Wischnewski spots). Experimental studies have been successfully performed using animal models to replicate this finding, however study animals have inevitably been subjected to a variety of additional stressors including food deprivation, restraint and partial immersion in water while conscious. As it is recognised that stress on its own may cause superficial erosive gastritis, a model has been developed to enable the study of the effects of hypothermia in isolation. 42 Sprague-Dawley rats were allowed free social contact and were fed and watered ad libitum prior to being anaesthetized with isoflurane. Once unconscious, rats were placed on drape cloth covering metal mesh platforms in a styrofoam box packed with ice. The apparatus enabled both maintenance of a specific low temperature (26 °C) in 14 animals, and continued reduction of core temperatures in the remaining 28 (who all died of hypothermia under anaesthesia). Examination of the gastric mucosa in both groups macroscopically and microscopically failed to demonstrate typical Wischnewski spots in any of the 42 animals. Thus, in this model, death from hypothermia occurred without the development of these lesions. These results suggest that stress may be a significant effect modifier in the development of Wischnewski spots in lethal hypothermia. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  9. Subjective Well-Being (SWB) Measures for Children were Developed within the PROMIS® Project: Presentation of First Results

    Science.gov (United States)

    Ravens-Sieberer, Ulrike; Devine, Janine; Bevans, Katherine; Riley, Anne W.; Moon, JeanHee; Salsman, John M.; Forrest, Christopher B.

    2014-01-01

    Objective The aims of this Patient Reported Outcome Measurement Information System (PROMIS®) study are (1) to conceptualize children's subjective well-being (SWB), and (2) to produce item pools with excellent content validity for calibration and use in computerized adaptive testings (CAT). Study Design and Setting Children's SWB was defined through semi-structured interviews with experts, children (age 8-17 years-old), parents, and a systematic literature review to identify item concepts comprehensively covering the full spectrum of SWB. Item concepts were transformed into item expressions and evaluated for comprehensibility using cognitive interviews, reading level analysis, and translatability review. Results Children's SWB comprises affective (Positive Affect) and global evaluation components (Life Satisfaction). Input from experts, children, parents, and the literature indicated that the eudaimonic dimension of SWB - i.e., a sense of meaning and purpose - could be evaluated. Item pools for Life Satisfaction (56 items), Positive Affect (53 items), and Meaning and Purpose (55 items) were produced. Small differences in comprehensibility of some items were observed between children and adolescents. Conclusion The SWB measures for children are the first to assess both the hedonic and eudaimonic aspects of SWB. Both children and youth seem to understand the concepts of a meaningful life, optimism, and goal orientation. PMID:24295987

  10. Presentation of the results of 1993-1994 of the peat production research area; Turvetuotanto - tutkimusalueen katsaus

    Energy Technology Data Exchange (ETDEWEB)

    Leinonen, A.

    1996-12-31

    The development target of the peat production research area of the Biomass research programme is to improve the competitivity of peat by reducing the production costs by 20 % (5-6 FIM/MWh) from the level of 1992 and to reduce the environmental load. The main targets of peat production, by which the target can be met, are ditching and preparation technologies, drying technology, machine technology, methodology, integration of wood harvesting and peat production, and application of the results of the Optimiturve research programme in practice. The objectives of the peat production research are possible to meet if the partial targets are met. Increment of the open-ditch distance from 20 m to 60 m reduces the production costs by 5.0 %, increment of the rate of utilization of solar radiation from 30 % to 40 % reduces the production costs by 8 %, reduction of the amount of residual peat from 3000 MWh to 1500 MWh reduces the costs by 6.5 %, development of light and firesafe machines by 3 %, and integrated harvesting of wood by 3 %. Meeting of the partial targets reduces the production costs by 24 %. The main research areas of peat production will be carried out further. The total funding of the peat production researches in 1993-1994 was 19.4 million FIM (9.7 million FIM/a). The share of the total funding of the research organization projects has been 6.7 million FIM and that of the company projects 12.7 million FIM. The share of the Finnish Ministry of Trade and Industry of the funding has been 9.0 million FIM (46 %)

  11. Unsteady flow volumes

    Energy Technology Data Exchange (ETDEWEB)

    Becker, B.G.; Lane, D.A.; Max, N.L.

    1995-03-01

    Flow volumes are extended for use in unsteady (time-dependent) flows. The resulting unsteady flow volumes are the 3 dimensional analog of streamlines. There are few examples where methods other than particle tracing have been used to visualize time varying flows. Since particle paths can become convoluted in time there are additional considerations to be made when extending any visualization technique to unsteady flows. We will present some solutions to the problems which occur in subdivision, rendering, and system design. We will apply the unsteady flow volumes to a variety of field types including moving multi-zoned curvilinear grids.

  12. Storage of LWR spent fuel in air. Volume 3, Results from exposure of spent fuel to fluorine-contaminated air

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, M.E.; Thomas, L.E.

    1995-06-01

    The Behavior of Spent Fuel in Storage (BSFS) Project has conducted research to develop data on spent nuclear fuel (irradiated U0{sub 2}) that could be used to support design, licensing, and operation of dry storage installations. Test Series B conducted by the BSFS Project was designed as a long-term study of the oxidation of spent fuel exposed to air. It was discovered after the exposures were completed in September 1990 that the test specimens had been exposed to an atmosphere of bottled air contaminated with an unknown quantity of fluorine. This exposure resulted in the test specimens reacting with both the oxygen and the fluorine in the oven atmospheres. The apparent source of the fluorine was gamma radiation-induced chemical decomposition of the fluoro-elastomer gaskets used to seal the oven doors. This chemical decomposition apparently released hydrofluoric acid (HF) vapor into the oven atmospheres. Because the Test Series B specimens were exposed to a fluorine-contaminated oven atmosphere and reacted with the fluorine, it is recommended that the Test Series B data not be used to develop time-temperature limits for exposure of spent nuclear fuel to air. This report has been prepared to document Test Series B and present the collected data and observations.

  13. Lung volumes, ventricular function and pulmonary arterial flow in children operated on for left-sided congenital diaphragmatic hernia: long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Abolmaali, Nasreddin; Koch, Arne [Dresden University of Technology, OncoRay - Molecular and Biological Imaging, Medical Faculty Carl Gustav Carus, Dresden (Germany); Goetzelt, Knut; Vogelberg, Christian [University Clinics Carl Gustav Carus, Dresden University of Technology, Clinic and Policlinic for Pediatrics - Pediatric Pulmonology, Dresden (Germany); Hahn, Gabriele [University Clinics Carl Gustav Carus, Dresden University of Technology, Institute and Policlinic for Radiology - Pediatric Radiology, Dresden (Germany); Fitze, Guido [University Clinics Carl Gustav Carus, Dresden University of Technology, Clinic and Policlinic for Pediatric Surgery, Dresden (Germany)

    2010-07-15

    To compare MRI-based functional pulmonary and cardiac measurements in the long-term follow-up of children operated on for left-sided congenital diaphragmatic hernia (CDH) with age- and body size-matched healthy controls. Twelve children who received immediate postnatal surgery for closure of isolated left-sided CDH were included and received basic medical examinations, pulmonary function testing and echocardiography. MRI included measurement of lung volume, ventricular function assessment and velocity-encoded imaging of the pulmonary arteries and was compared with the data for 12 healthy children matched for age and body size. While patients' clinical test results were not suspicious, comparison between the MRI data for patients and those for healthy controls revealed significant differences. In patients, the volumes of the left lungs were increased and the tidal volume was larger on the right side. While the stroke volumes of both ventricles were reduced, heart rate and ejection fraction were increased. Flow, acceleration time and cross-sectional area of the left pulmonary artery were reduced. Functional MRI detected pulmonary and cardiac findings in the late follow-up of CDH children which may be missed by standard clinical methods and might be relevant for decisions regarding late outcome and treatment. (orig.)

  14. Annual Proceedings of Selected Papers on the Practice of Educational Communications and Technology Presented at the Annual Convention of the Association for Educational Communications and Technology (32nd, Louisville, KY, 2009). Volume 2

    Science.gov (United States)

    Simonson, Michael, Ed.

    2009-01-01

    For the thirty-second year, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. This volume includes papers presented at the national convention of the Association for Educational Communications and Technology held in Louisville, KY. This…

  15. Annual Proceedings of Selected Papers on the Practice of Education Communications and Technology Presented at the Annual Convention of the Association for Educational Communications and Technology (38th, Indianapolis, Indiana, 2015). Volume 2

    Science.gov (United States)

    Simonson, Michael, Ed.

    2015-01-01

    For the thirty-eighth time, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the annual AECT Convention in Indianapolis, Indiana. The Proceedings of AECT's Convention are published in two…

  16. Iodine status and thyroid volume changes during pregnancy: results of a survey in Aran Valley (Catalan Pyrenees).

    Science.gov (United States)

    Vila, L; Legaz, G; Barrionuevo, C; Espinel, M L; Casamitjana, R; Muñoz, J; Serra-Prat, M; Puig-Domingo, M

    2008-10-01

    The Aran Valley (Catalan Pyrenees, Spain) has a long-standing history of iodine deficiency. A survey was performed to determine the prevalence of iodine deficiency (urinary iodine<150 microg/l) in pregnant women from this region during the 1st and 3rd trimesters of gestation and to evaluate the changes in thyroid volume (TV). Of all the registered pregnancies in the area, in the first semester of the year 2000, 35 women (90%) were studied. Urinary iodine (UI) was measured and a thyroid ultrasonography performed during the 1st and 3rd trimester and their iodized salt consumption was recorded. Of the whole group, 77.1% of pregnant women reported regular intake of iodized salt.Median UI in the first trimester was 134.5 microg/l. Iodine deficiency was observed in 57.1%of women in the 1st trimester and in 46.7% in the 3rd trimester (p=0.1). In 10 women supplemented with iodine (150 microg/day) from the 1st trimester, median UI increased from 138.5 microg/l in the 1st trimester to 168 mug/l in the 3rd trimester (p=0.037), and no changes were observed in the rest. TV increased in the whole group during pregnancy (median 7.5 ml in the 1st trimester vs 9.5 ml in the 3rd trimester; p<0.001). The change in TV was significant in those cases with iodine deficiency in the 1st trimester, 3rd trimester or both (median 7.5ml in the 1st trimester vs 10.01 ml in the 3rd trimester; p=0.001) and between multiparous women (8.2 vs 10.9 ml; p=0.005). In 2000, iodine deficiency among pregnant women in the Aran Valley was still very high. Iodine deficiency as well as multiparity contributes to goitrogenesis during pregnancy. Taking this data in account, pre-conceptional supplements with iodine are required for its prevention.

  17. [Thyroid volume and iodine supply of 6 to 17 year old students. Results 3 years after the introduction of increased iodized salt].

    Science.gov (United States)

    Gallowitsch, H J; Mikosch, P; Kresnik, E; Gomez, I; Plöb, J; Pipam, W; Lind, P

    1994-12-01

    In Austria, a law stipulating that table salt should be iodized with 10 mg Kl/kg was introduced in 1963. Nevertheless, investigations carried out between 1982 and 1984 on iodine supply and goitre frequency revealed that there was a general iodine deficiency of first to second degree according to WHO criteria. These results led to an increase in salt iodization to 20 mg Kl/kg in 1990. The aim of the study was to determine iodine supply and thyroid volumes of schoolchildren 3 years thereafter. 734 children at primary and secondary schools were examined. The mean value of iodine excretion was 121 micrograms/g Cr, corresponding to an improvement in iodine intake. Compared to previous data, the corresponding age groups showed lower mean thyroid volumes.

  18. Measurement of volume change in cementitious materials at early ages - Review of testing protocols and interpretation of results

    DEFF Research Database (Denmark)

    Sant, Gaurav; Lura, Pietro; Weiss, Jason

    2006-01-01

    measurement in a rigid mold, and the ASTM C 157 standard. The results of the autogenous and chemical shrinkage tests are compared with one another to describe fully early-age length change. It is shown that through careful experimentation and interpretation, the results of these tests can be completely...

  19. The long-term impact of early life poverty on orbitofrontal cortex volume in adulthood: results from a prospective study over 25 years.

    Science.gov (United States)

    Holz, Nathalie E; Boecker, Regina; Hohm, Erika; Zohsel, Katrin; Buchmann, Arlette F; Blomeyer, Dorothea; Jennen-Steinmetz, Christine; Baumeister, Sarah; Hohmann, Sarah; Wolf, Isabella; Plichta, Michael M; Esser, Günter; Schmidt, Martin; Meyer-Lindenberg, Andreas; Banaschewski, Tobias; Brandeis, Daniel; Laucht, Manfred

    2015-03-01

    Converging evidence has highlighted the association between poverty and conduct disorder (CD) without specifying neurobiological pathways. Neuroimaging research has emphasized structural and functional alterations in the orbitofrontal cortex (OFC) as one key mechanism underlying this disorder. The present study aimed to clarify the long-term influence of early poverty on OFC volume and its association with CD symptoms in healthy participants of an epidemiological cohort study followed since birth. At age 25 years, voxel-based morphometry was applied to study brain volume differences. Poverty (0=non-exposed (N=134), 1=exposed (N=33)) and smoking during pregnancy were determined using a standardized parent interview, and information on maternal responsiveness was derived from videotaped mother-infant interactions at the age of 3 months. CD symptoms were assessed by diagnostic interview from 8 to 19 years of age. Information on life stress was acquired at each assessment and childhood maltreatment was measured using retrospective self-report at the age of 23 years. Analyses were adjusted for sex, parental psychopathology and delinquency, obstetric adversity, parental education, and current poverty. Individuals exposed to early life poverty exhibited a lower OFC volume. Moreover, we replicated previous findings of increased CD symptoms as a consequence of childhood poverty. This effect proved statistically mediated by OFC volume and exposure to life stress and smoking during pregnancy, but not by childhood maltreatment and maternal responsiveness. These findings underline the importance of studying the impact of early life adversity on brain alterations and highlight the need for programs to decrease income-related disparities.

  20. St. Juliens Creek Ocean Construction Equipment Inventory Support Facility Five Year Plan. Volume 1. Results and Discussion.

    Science.gov (United States)

    1983-08-01

    present use has been as a paint locker The nearest fire hydrant is 30 feet to the south and the for storage of paint and caustic materials. The 81...to these repairs, the entire interior No vertical storage, of the building requires repainting, as it is peeling badly over 75% of the wall and...1,955 power deteriorated windows 86/OMN Interior paint Scrape & paint 10,260 peeling 86/OMN Floor planks Replace 3,260 broken 86/OMN Heat exchanger

  1. Measurement of volume change in cementitious materials at early ages - Review of testing protocols and interpretation of results

    DEFF Research Database (Denmark)

    Sant, Gaurav; Lura, Pietro; Weiss, Jason

    2006-01-01

    Early-age cracking in concrete bridge decks, pavements, and superstructure elements has served as the impetus for substantial research on early-age shrinkage in cementitious materials. Much of this research has indicated how mixture proportions, constituent materials, and construction operations...... measurement in a rigid mold, and the ASTM C 157 standard. The results of the autogenous and chemical shrinkage tests are compared with one another to describe fully early-age length change. It is shown that through careful experimentation and interpretation, the results of these tests can be completely...

  2. Midlife and Late-Life Cardiorespiratory Fitness and Brain Volume Changes in Late Adulthood: Results From the Baltimore Longitudinal Study of Aging

    Science.gov (United States)

    Studenski, Stephanie A.; Resnick, Susan M.; Davatzikos, Christos; Ferrucci, Luigi

    2016-01-01

    Background. Higher cardiorespiratory fitness (CRF) is cross-sectionally associated with more conserved brain volume in older age, but longitudinal studies are rare. This study examined whether higher midlife CRF was prospectively associated with slower atrophy, which in turn was associated with higher late-life CRF. Methods. Brain volume by magnetic resonance imaging was determined annually from 1994 to 2003 in 146 participants (M baseline age = 69.6 years). Peak oxygen uptake on a treadmill yielded estimated midlife CRF in 138 and late-life CRF in 73 participants. Results. Higher midlife CRF was associated with greater middle temporal gyrus, perirhinal cortex, and temporal and parietal white matter, but was not associated with atrophy progression. Slower atrophy in middle frontal and angular gyri was associated with higher late-life CRF, independent of CRF at baseline magnetic resonance imaging. Conclusions. Higher midlife CRF may play a role in preserving middle and medial temporal volumes in late adulthood. Slower atrophy in middle frontal and angular gyri may predict late-life CRF. PMID:25896993

  3. An analysis of Chemical Stockpile Emergency Preparedness Program exercise results. Volume 2: Preliminary evaluation and analysis of CSEPP exercise database

    Energy Technology Data Exchange (ETDEWEB)

    Wernette, D.; Lerner, K.

    1998-06-01

    This study investigated the quality and usefulness of the information in the Chemical Stockpile Emergency Preparedness Program (CSEPP) exercise database. It incorporates the results of two separate analytical efforts. The first effort investigated the process of assigning standardized codes to issues identified in CSEPP exercise reports. A small group of issues was coded independently by each of several individuals, and the results of the individual codings were compared. Considerable differences were found among the individuals` codings. The second effort consisted of a statistical multivariate analysis, to investigate whether exercise issues are evenly distributed among exercise tabs, sites, and objectives. It was found that certain tabs, sites, and objectives were disproportionately associated with problem areas in exercises. In some cases, these problem areas have persisted over time, but in other cases they have undergone significant shifts over the time span of the investigation. The study concludes that the database can be a useful resource for analyzing problem areas and setting priorities for CSEPP program resources. However, some further analyses should be performed in order to more fully explore the data and increase confidence in the results.

  4. Mean corpuscular volume of control red blood cells determines the interpretation of eosin-5'-maleimide (EMA) test result in infants aged less than 6 months.

    Science.gov (United States)

    Ciepiela, Olga; Adamowicz-Salach, Anna; Bystrzycka, Weronika; Łukasik, Jan; Kotuła, Iwona

    2015-08-01

    Eosin-5'-maleimide (EMA) binding test is a flow cytometric test used to detect hereditary spherocytosis (HS). To perform the test sample from patients, 5-6 reference samples of red blood are needed. Our aim was to investigate how the mean corpuscular volume (MCV) of red blood cells influences on the value of fluorescence of bounded EMA dye and how the choice of reference samples affects the test result. EMA test was performed in peripheral blood from 404 individuals, including 31 children suffering from HS. Mean fluorescence channel of EMA-RBCs was measured with Cytomics FC500 flow cytometer. Mean corpuscular volume of RBCs was assessed with LH750 Beckman Coulter. Statistical analysis was performed using Graph Pad Prism. The correlation Spearman coefficient between mean channel of fluorescence of EMA-RBCs and MCV was r = 0.39, p result might be negative. Due to different MCV values of RBCs in infancy and ca. Three months later, EMA test in neonates might be interpreted falsely negative. Samples from children younger than 3 months old had EMA test result 86.1 ± 11.7 %, whereas same samples that analyzed 4.1 ± 2.1 later had results of 75.4 ± 4.5 %, p results; thus, we recommend selection of reference samples with MCV in range of ±2 fL compared to MCV of patient RBC's.

  5. Top Value-Added Chemicals from Biomass - Volume II—Results of Screening for Potential Candidates from Biorefinery Lignin

    Energy Technology Data Exchange (ETDEWEB)

    Holladay, John E.; White, James F.; Bozell, Joseph J.; Johnson, David

    2007-10-01

    This report evaluates lignin’s role as a renewable raw material resource. Opportunities that arise from utilizing lignin fit into one of three categories: 1)power, fuel and syngas (generally near-term opportunities) 2) macromolecules (generally medium-term opportunities) 3) aromatics and miscellaneous monomers (long-term opportunities). Biorefineries will receive and process massive amounts of lignin. For this reason, how lignin can be best used to support the economic health of the biorefinery must be defined. An approach that only considers process heat would be shortsighted. Higher value products present economic opportunities and the potential to significantly increase the amount of liquid transportation fuel available from biomass. In this analysis a list of potential uses of lignin was compiled and sorted into “product types” which are broad classifications (listed above as power—fuel—syngas; macromolecules; and aromatics). In the first “product type” (power—fuel—gasification) lignin is used purely as a carbon source and aggressive means are employed to break down its polymeric structure. In the second “product type” (macromolecules) the opposite extreme is considered and advantage of the macromolecular structure imparted by nature is retained in high-molecular weight applications. The third “product type” (aromatics) lies somewhere between the two extremes and employs technologies that would break up lignin’s macromolecular structure but maintain the aromatic nature of the building block molecules. The individual opportunities were evaluated based on their technical difficulty, market, market risk, building block utility, and whether a pure material or a mixture would be produced. Unlike the “Sugars Top 10” report it was difficult to identify the ten best opportunities, however, the potential opportunities fell nicely into near-, medium- and long-term opportunities. Furthermore, the near-, medium- and long-term opportunities

  6. Development of grout formulations for 106-AN waste: Mixture-experiment results and analysis. Volume 1, Narrative and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Spence, R.D.; McDaniel, E.W. [Oak Ridge National Lab., TN (United States); Anderson, C.M.; Lokken, R.O.; Piepel, G.F. [Pacific Northwest Lab., Richland, WA (United States)

    1993-09-01

    Twenty potential ingredients were identified for use in developing a 106-AN grout formulation, and 18 were subsequently obtained and tested. Four ingredients-Type II-LA (moderate heat of hydration) Portland cement, Class F fly ash, attapulgite 150 drilling clay, and ground air-cooled blast-furnace slag (GABFS) were selected for developing the 106-AN grout formulations. A mixture experiment was designed and conducted around the following formulation: 2.5 lb of cement per gallon, 1.2 lb of fly ash per gallon, 0.8 lb of attapulgite per gallon, and 3.5 lb of GABFS per gallon. Reduced empirical models were generated from the results of the mixture experiment. These models were used to recommend several grout formulations for 106-AN. Westinghouse Hanford Company selected one of these formulations to be verified for use with 106-AN and a backup formulation in case problems arise with the first choice.

  7. Summary Report on Phase I Results from the 3D Printing in Zero G Technology Demonstration Mission, Volume I

    Science.gov (United States)

    Prater, T. J.; Bean, Q. A.; Beshears, R. D.; Rolin, T. D.; Werkheiser, N. J.; Ordonez, E. A.; Ryan, R. M.; Ledbetter, F. E., III

    2016-01-01

    Human space exploration to date has been confined to low-Earth orbit and the Moon. The International Space Station (ISS) provides a unique opportunity for researchers to prove out the technologies that will enable humans to safely live and work in space for longer periods of time and venture beyond the Earth/Moon system. The ability to manufacture parts in-space rather than launch them from Earth represents a fundamental shift in the current risk and logistics paradigm for human spaceflight. In September 2014, NASA, in partnership with Made In Space, Inc., launched the 3D Printing in Zero-G technology demonstration mission to explore the potential of additive manufacturing for in-space applications and demonstrate the capability to manufacture parts and tools on orbit using fused deposition modeling. This Technical Publication summarizes the results of testing to date of the ground control and flight prints from the first phase of this ISS payload.

  8. Government Performance and Results Act: Performance plan FY 1999, U.S. Nuclear Regulatory Commission. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Fuches, J.L.

    1998-02-01

    The Nuclear Regulatory Commission`s (NRC) strategic plan [NUREG-1614, Vol. 1, September 1997] establishes a strategic framework that will guide future decision-making and will help the NRC continue to meet its responsibility for protecting public health and safety, promoting the common defense and security, and protecting the environment. This performance plan complements the agency`s strategic plan by setting annual goals with measurable target levels of performance for FY 1999, as required by the Government Performance and Results Act. No significant contribution was made to the preparation of the performance plan by any non-Federal entity. However, a contractor was used to help facilitate discussions and resolution of issues. Within six months after the close of FY 1999, the NRC will submit to the President and the Congress a report on program performance for FY 1999. This performance report will review the success of the agency in achieving the performance goals established for FY 1999. Where those goals have been achieved, the underlying assumptions and strategies will be examined to ensure that continued applicability is warranted in the future. If any of the FY 1999 performance goals are not met, the agency will conduct a thorough analysis of why it did not meet the goal and the actions necessary to meet-the goal in the future. One result of this analysis will be the documentation of plans and schedules for achieving the established performance goal. If the analysis should indicate that the performance goal is impractical or infeasible, the performance report will document why that is the case and what action is recommended.

  9. In situ vitrification demonstration at Pit 1, Oak Ridge National Laboratory. Volume 1: Results of treatability study

    Energy Technology Data Exchange (ETDEWEB)

    Spalding, B.P.; Naney, M.T.; Cline, S.R.; Bogle, M.A. [Oak Ridge National Lab., TN (United States). Environmental Sciences Div.; Tixier, J.S. [Pacific Northwest National Lab., Richland, WA (United States)

    1997-12-01

    A treatability study was initiated in October 1993 to apply in situ vitrification (ISV) to at least two segments of Oak Ridge National Laboratory (ORNL) seepage Pit 1 by the end of fiscal year (FY) 1995. This treatability study was later extended to include all of Pit 1 and was performed to support a possible Interim Record of Decision or removal action for closure of one or more of the seepage pits and trenches beginning as early as FY 1997. This treatability study was carried out to establish the field-scale technical performance of ISV for (1) attaining the required depth, nominally 15 ft, to incorporate source contamination within and beneath the pits; (2) demonstrating field capability for the overlap of melt settings which will be necessary to achieve fused, melted segments of the source contamination; (3) demonstrating off-gas handling technology for accommodating and minimizing the volatilization of {sup 137}Cs; (4) demonstrating adequate site characterization techniques to predict ISV melting kinetics, processing temperatures, and product durability; and (5) promoting public acceptance of ISV technology by demonstrating its safety, implementability, site impacts, and air emissions and by coordinating the treatability study within the regulatory closure process. In April 1996 an expulsion of an estimated 10% of the 196 Mg (216 tons) melt body occurred resulting in significant damage to ISV equipment and, ultimately, led to an indefinite suspension of further ISV operations at Pit 1. This report summarizes the technical accomplishments and status of the project in fulfilling these objectives through September 1997.

  10. Treatment of Locally Advanced Vaginal Cancer With Radiochemotherapy and Magnetic Resonance Image-Guided Adaptive Brachytherapy: Dose-Volume Parameters and First Clinical Results

    Energy Technology Data Exchange (ETDEWEB)

    Dimopoulos, Johannes C.A. [Department of Radiation Oncology, Metropolitan Hospital, Athens (Greece); Schmid, Maximilian P., E-mail: maximilian.schmid@akhwien.at [Department of Radiotherapy, Medical University of Vienna, Vienna (Austria); Fidarova, Elena; Berger, Daniel; Kirisits, Christian; Poetter, Richard [Department of Radiotherapy, Medical University of Vienna, Vienna (Austria)

    2012-04-01

    Purpose: To investigate the clinical feasibility of magnetic resonance image-guided adaptive brachytherapy (IGABT) for patients with locally advanced vaginal cancer and to report treatment outcomes. Methods and Materials: Thirteen patients with vaginal cancer were treated with external beam radiotherapy (45-50.4 Gy) plus IGABT with or without chemotherapy. Distribution of International Federation of Gynecology and Obstetrics stages among patients were as follows: 4 patients had Stage II cancer, 5 patients had Stage III cancer, and 4 patients had Stage IV cancer. The concept of IGABT as developed for cervix cancer was transferred and adapted for vaginal cancer, with corresponding treatment planning and reporting. Doses were converted to the equivalent dose in 2 Gy, applying the linear quadratic model ({alpha}/{beta} = 10 Gy for tumor; {alpha}/{beta} = 3 for organs at risk). Endpoints studied were gross tumor volume (GTV), dose-volume parameters for high-risk clinical target volume (HRCTV), and organs at risk, local control (LC), adverse side effects, and survival. Results: The mean GTV ({+-} 1 standard deviation) at diagnosis was 45.3 ({+-}30) cm{sup 3}, and the mean GTV at brachytherapy was 10 ({+-}14) cm{sup 3}. The mean D90 for the HRCTV was 86 ({+-}13) Gy. The mean D2cc for bladder, urethra, rectum, and sigmoid colon were 80 ({+-}20) Gy, 76 ({+-}16) Gy, 70 ({+-}9) Gy, and 60 ({+-}9) Gy, respectively. After a median follow-up of 43 months (range, 19-87 months), one local recurrence and two distant metastases cases were observed. Actuarial LC and overall survival rates at 3 years were 92% and 85%. One patient with Stage IVA and 1 patient with Stage III disease experienced fistulas (one vesicovaginal, one rectovaginal), and 1 patient developed periurethral necrosis. Conclusions: The concept of IGABT, originally developed for treating cervix cancer, appears to be applicable to vaginal cancer treatment with only minor adaptations. Dose-volume parameters for HRCTV and

  11. The role of informal dimensions of safety in high-volume organisational routines: an ethnographic study of test results handling in UK general practice.

    Science.gov (United States)

    Grant, Suzanne; Checkland, Katherine; Bowie, Paul; Guthrie, Bruce

    2017-04-27

    The handling of laboratory, imaging and other test results in UK general practice is a high-volume organisational routine that is both complex and high risk. Previous research in this area has focused on errors and harm, but a complementary approach is to better understand how safety is achieved in everyday practice. This paper ethnographically examines the role of informal dimensions of test results handling routines in the achievement of safety in UK general practice and how these findings can best be developed for wider application by policymakers and practitioners. Non-participant observation was conducted of high-volume organisational routines across eight UK general practices with diverse organisational characteristics. Sixty-two semi-structured interviews were also conducted with the key practice staff alongside the analysis of relevant documents. While formal results handling routines were described similarly across the eight study practices, the everyday structure of how the routine should be enacted in practice was informally understood. Results handling safety took a range of local forms depending on how different aspects of safety were prioritised, with practices varying in terms of how they balanced thoroughness (i.e. ensuring the high-quality management of results by the most appropriate clinician) and efficiency (i.e. timely management of results) depending on a range of factors (e.g. practice history, team composition). Each approach adopted created its own potential risks, with demands for thoroughness reducing productivity and demands for efficiency reducing handling quality. Irrespective of the practice-level approach adopted, staff also regularly varied what they did for individual patients depending on the specific context (e.g. type of result, patient circumstances). General practices variably prioritised a legitimate range of results handling safety processes and outcomes, each with differing strengths and trade-offs. Future safety

  12. Radio-anatomy Atlas for delineation SIRIADE web site: features and 1 year results; Site de radio-anatomie et d'aide a la delineation (SIRIADE): presentation et bilan a un an

    Energy Technology Data Exchange (ETDEWEB)

    Denisa, F. [Centre Jean-Bernard, Clinique Victor-Hugo, 72 - Le Mans (France); Pointreau, Y. [Clinique d' oncologie radiotherapie, Centre Henry-S.-Kaplan, CHU Bretonneau, 37 - Tours (France)

    2010-07-01

    3-D conformal radiotherapy is based on accurate target volumes delineation. Radio-anatomy knowledge's are useful but sometimes difficult to obtain. Moreover, the sources of recommendations for volume definition are disparate. We thus developed a free radio-anatomy web site dedicated to volumes delineation for radiation-oncologists (www.siriade.org). This web site is a search engine allowing to access to delineation characteristics of main tumours illustrated with clinical cases. It does not aim to provide guidelines. Its main purpose is to provide an iconographic training support with frequent up-datings. We present the features of this web site and one year connexion statistics. (authors)

  13. Psychological aspects of driver behaviour : papers presented at the international symposium on psychological aspects of driver behaviour, Noordwijkerhout, The Netherlands, August 2-6, 1971. Volume 1: Driver behaviour. Volume 2: Applied research.

    NARCIS (Netherlands)

    1971-01-01

    The object of the symposium was to improve the communication between the field af driving task research, bomen performance theory and research applied to the design of vehicle and road and to driver education. For abstracts of the papers presented at the conference see B 864 - B 913 (IRRD 205245 to

  14. Randomized Noninferiority Trial of Reduced High-Dose Volume Versus Standard Volume Radiation Therapy for Muscle-Invasive Bladder Cancer: Results of the BC2001 Trial (CRUK/01/004)

    Energy Technology Data Exchange (ETDEWEB)

    Huddart, Robert A., E-mail: robert.huddart@icr.ac.uk [Institute of Cancer Research, Royal Marsden NHSFT (National Health Service Foundation Trust) (United Kingdom); Hall, Emma [Institute of Cancer Research (United Kingdom); Hussain, Syed A. [University of Liverpool (United Kingdom); Jenkins, Peter [Gloucestershire Hospitals NHSFT (United Kingdom); Rawlings, Christine [South Devon Healthcare NHSFT (United Kingdom); Tremlett, Jean [Brighton and Sussex University Hospitals (United Kingdom); Crundwell, Malcolm [Royal Devon and Exeter NHSFT (United Kingdom); Adab, Fawzi A. [University Hospital of North Staffordshire NHS Trust (United Kingdom); Sheehan, Denise [Royal Devon and Exeter NHSFT (United Kingdom); Syndikus, Isabel [Clatterbridge Cancer Centre NHSFT (United Kingdom); Hendron, Carey [University of Birmingham (United Kingdom); Lewis, Rebecca; Waters, Rachel [Institute of Cancer Research (United Kingdom); James, Nicholas D. [University of Birmingham (United Kingdom)

    2013-10-01

    Purpose: To test whether reducing radiation dose to uninvolved bladder while maintaining dose to the tumor would reduce side effects without impairing local control in the treatment of muscle-invasive bladder cancer. Methods and Materials: In this phase III multicenter trial, 219 patients were randomized to standard whole-bladder radiation therapy (sRT) or reduced high-dose volume radiation therapy (RHDVRT) that aimed to deliver full radiation dose to the tumor and 80% of maximum dose to the uninvolved bladder. Participants were also randomly assigned to receive radiation therapy alone or radiation therapy plus chemotherapy in a partial 2 × 2 factorial design. The primary endpoints for the radiation therapy volume comparison were late toxicity and time to locoregional recurrence (with a noninferiority margin of 10% at 2 years). Results: Overall incidence of late toxicity was less than predicted, with a cumulative 2-year Radiation Therapy Oncology Group grade 3/4 toxicity rate of 13% (95% confidence interval 8%, 20%) and no statistically significant differences between groups. The difference in 2-year locoregional recurrence free rate (RHDVRT − sRT) was 6.4% (95% confidence interval −7.3%, 16.8%) under an intention to treat analysis and 2.6% (−12.8%, 14.6%) in the “per-protocol” population. Conclusions: In this study RHDVRT did not result in a statistically significant reduction in late side effects compared with sRT, and noninferiority of locoregional control could not be concluded formally. However, overall low rates of clinically significant toxicity combined with low rates of invasive bladder cancer relapse confirm that (chemo)radiation therapy is a valid option for the treatment of muscle-invasive bladder cancer.

  15. Annual Proceedings of Selected Research and Development Papers Presented at the Annual Convention of the Association for Educational Communications and Technology - Volume 1 and Selected Papers on the Practice of Educational Communications and Technology - Volume 2 (34th, Jacksonville, Florida, 2011)

    Science.gov (United States)

    Simonson, Michael, Ed.

    2011-01-01

    For the thirty-fourth year, the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. Papers published in this volume were presented at the annual AECT Convention in Jacksonville, FL. A limited quantity of these Proceedings were printed and sold in both hardcopy and electronic…

  16. Prof. Samuel ting presents results from AMS experiment at CERN main auditorium. Geneva 3 April 2013. The international team running the Alpha Magnetic Spectrometer (AMS1) today announced the first results in its search for dark matter

    CERN Multimedia

    Samuel Morier-Genoud

    2013-01-01

    Geneva 3 April 2013. The international team running the Alpha Magnetic Spectrometer (AMS) today announced the first results in its search for dark matter. The results, presented by AMS spokesperson Professor Samuel Ting in a seminar at CERN, are to be published in the journal Physical Review Letters. They report the observation of an excess of positrons in the cosmic ray flux

  17. Results and summary of voting among the audience during presentation and discussion of Medullary Thyroid Carcinoma clinical guidelines prepared by American Thyroid Association

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, Ulla; Soderstrom, Folke

    2013-01-01

    , related to the specific aspect, were presented to the audience. The responses from the audience were collected by an AudioResponseSystem (ARS voting system). The results of the voting showed in summary that European expert opinion leaders and an audience of specialists in treatment of Medullary Carcinoma...

  18. A Consumer's Guide to Benchmark Dose Models: Results of U.S. EPA Testing of 14 Dichotomous, 8 Continuous, and 6 Developmental Models (Presentation)

    Science.gov (United States)

    Benchmark dose risk assessment software (BMDS) was designed by EPA to generate dose-response curves and facilitate the analysis, interpretation and synthesis of toxicological data. Partial results of QA/QC testing of the EPA benchmark dose software (BMDS) are presented. BMDS pr...

  19. Site Environmental Report for 2009, Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Suying

    2010-08-19

    Volume II of the Site Environmental Report for 2009 is provided by Ernest Orlando Lawrence Berkeley National Laboratory as a supplemental appendix to Volume I, which contains the body of the report. Volume II contains the environmental monitoring and sampling data used to generate summary results of routine and nonroutine sampling at the Laboratory, except for groundwater sampling data, which may be found in the reports referred to in Chapter 4 of Volume I. The results from sample collections are more comprehensive in Volume II than in Volume I: for completeness, all results from sample collections that began or ended in calendar year (CY) 2009 are included in this volume. However, the samples representing CY 2008 data have not been used in the summary results that are reported in Volume I. (For example, although ambient air samples collected on January 6, 2009, are presented in Volume II, they represent December 2008 data and are not included in Table 4-2 in Volume I.) When appropriate, sampling results are reported in both conventional and International System (SI) units. For some results, the rounding procedure used in data reporting may result in apparent differences between the numbers reported in SI and conventional units. (For example, stack air tritium results reported as < 1.5 Bq/m3 are shown variously as < 39 and < 41 pCi/m3. Both of these results are rounded correctly to two significant digits.)

  20. Goal-Directed Fluid Therapy Using Stroke Volume Variation Does Not Result in Pulmonary Fluid Overload in Thoracic Surgery Requiring One-Lung Ventilation

    Directory of Open Access Journals (Sweden)

    Sebastian Haas

    2012-01-01

    Full Text Available Background. Goal-directed fluid therapy (GDT guided by functional parameters of preload, such as stroke volume variation (SVV, seems to optimize hemodynamics and possibly improves clinical outcome. However, this strategy is believed to be rather fluid aggressive, and, furthermore, during surgery requiring thoracotomy, the ability of SVV to predict volume responsiveness has raised some controversy. So far it is not known whether GDT is associated with pulmonary fluid overload and a deleterious reduction in pulmonary function in thoracic surgery requiring one-lung-ventilation (OLV. Therefore, we assessed the perioperative course of extravascular lung water index (EVLWI and paO2/FiO2-ratio during and after thoracic surgery requiring lateral thoracotomy and OLV to evaluate the hypothesis that fluid therapy guided by SVV results in pulmonary fluid overload. Methods. A total of 27 patients (group T were enrolled in this prospective study with 11 patients undergoing lung surgery (group L and 16 patients undergoing esophagectomy (group E. Goal-directed fluid management was guided by SVV (SVV 0.05 in EVLWI during the observation period (BL: 7.8 ± 2.5, 24postop: 8.1 ± 2.4 mL/kg. A subgroup analysis for group L and group E also did not reveal significant changes of EVLWI. The paO2/FiO2-ratio decreased significantly during the observation period (group L: BL: 462 ± 140, OLVterm15: 338 ± 112 mmHg; group E: BL: 389 ± 101, 24postop: 303 ± 74 mmHg but remained >300 mmHg except during OLV. Conclusions. SVV-guided fluid management in thoracic surgery requiring lateral thoracotomy and one-lung ventilation does not result in pulmonary fluid overload. Although oxygenation was reduced, pulmonary function remained within a clinically acceptable range.

  1. Quality of claims, references and the presentation of risk results in medical journal advertising: a comparative study in Australia, Malaysia and the United States

    Directory of Open Access Journals (Sweden)

    Vitry Agnes I

    2010-05-01

    Full Text Available Abstract Background Journal advertising is used by pharmaceutical companies to disseminate medicine information to doctors. The quality of claims, references and the presentation of risk results in Australia and the US has been questioned in several studies. No recent evidence is available on the quality of claims, references and the presentation of risk results in journal advertising in Australia and the US and no Malaysian data have been published. The aim of this study was to compare the quality of claims, references and the presentation of risk results in journal advertising in these three countries. Methods A consecutive sample of 85 unique advertisements from each country was selected from journal advertising published between January 2004 to December 2006. Claims, references and the presentation of risk results in medical journal advertising were compared between the three countries. Results Less than one-third of the claims were unambiguous claims (Australia, 30%, Malaysia 17%, US, 23%. In Malaysia significantly less unambiguous claims were provided than in Australia and the US (P Conclusions The majority of claims were vague suggesting poor quality of claims in journal advertising in these three countries. Evidence from a randomized controlled trial, systematic review or meta- analysis was commonly cited to support claims. However, the more frequent use of data that have not been published and independently reviewed in the US compared to Australia and Malaysia raises questions on the quality of references in the US. The use of relative rather than absolute benefits may overemphasize the benefit of medicines which may leave doctors susceptible to misinterpreting information.

  2. A study of toxic emissions from a coal-fired power plant utilizing the SNOX innovative clean coal technology demonstration. Volume 1, Sampling/results/special topics: Final report

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    This study was one of a group of assessments of toxic emissions from coal-fired power plants, conducted for DOE during 1993. The motivation for those assessments was the mandate in the 1990 Clean Air Act Amendments that a study be made of emissions of hazardous air pollutants (HAPs) from electric utilities. The report is organized in two volumes. Volume 1: Sampling describes the sampling effort conducted as the basis for this study; Results presents the concentration data on HAPs in the several power plant streams, and reports the results of evaluations and calculations conducted with those data; and Special Topics report on issues such as comparison of sampling methods and vapor/solid distributions of HAPs. Volume 2: Appendices include quality assurance/quality control results, uncertainty analysis for emission factors, and data sheets. This study involved measurements of a variety of substances in solid, liquid, and gaseous samples from input, output, and process streams at the Innovative Clean Coal Technology Demonstration (ICCT) of the Wet Sulfuric Acid-Selective Catalytic Reduction (SNOX) process. The SNOX demonstration is being conducted at Ohio Edison`s Niles Boiler No. 2 which uses cyclone burners to burn bituminous coal. A 35 megawatt slipstream of flue gas from the boiler is used to demonstrate SNOX. The substances measured at the SNOX process were the following: 1. Five major and 16 trace elements, including mercury, chromium, cadmium, lead, selenium, arsenic, beryllium, and nickel; 2. Acids and corresponding anions (HCl, HF, chloride, fluoride, phosphate, sulfate); 3. Ammonia and cyanide; 4. Elemental carbon; 5. Radionuclides; 6. Volatile organic compounds (VOC); 7. Semi-volatile compounds (SVOC) including polynuclear aromatic hydrocarbons (PAH); and 8. Aldehydes.

  3. Renormalized Volume

    Science.gov (United States)

    Gover, A. Rod; Waldron, Andrew

    2017-09-01

    We develop a universal distributional calculus for regulated volumes of metrics that are suitably singular along hypersurfaces. When the hypersurface is a conformal infinity we give simple integrated distribution expressions for the divergences and anomaly of the regulated volume functional valid for any choice of regulator. For closed hypersurfaces or conformally compact geometries, methods from a previously developed boundary calculus for conformally compact manifolds can be applied to give explicit holographic formulæ for the divergences and anomaly expressed as hypersurface integrals over local quantities (the method also extends to non-closed hypersurfaces). The resulting anomaly does not depend on any particular choice of regulator, while the regulator dependence of the divergences is precisely captured by these formulæ. Conformal hypersurface invariants can be studied by demanding that the singular metric obey, smoothly and formally to a suitable order, a Yamabe type problem with boundary data along the conformal infinity. We prove that the volume anomaly for these singular Yamabe solutions is a conformally invariant integral of a local Q-curvature that generalizes the Branson Q-curvature by including data of the embedding. In each dimension this canonically defines a higher dimensional generalization of the Willmore energy/rigid string action. Recently, Graham proved that the first variation of the volume anomaly recovers the density obstructing smooth solutions to this singular Yamabe problem; we give a new proof of this result employing our boundary calculus. Physical applications of our results include studies of quantum corrections to entanglement entropies.

  4. Continuous emission monitoring for industrial boilers, General Motors Corporation, Assembly Division, St. Louis, Missouri. Volume I. System configuration and results of the operational test period. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Huckabee, D.; Diamond, S.; Porter, T.; McGlew, P.

    1980-06-01

    The objective of this program was to continuously monitor sulfur dioxide (SO/sub 2/) removal efficiencies of a flue gas desulfurization (FGD) system installed an industrial boiler for 30 days. The data will be used to substantiate the applicability of extractive monitors to industrial boilers and to aid in formulating New Source Performance Standards (NSPS) for industrial boilers. The monitoring program was conducted at the General Motors Corporation, Assembly Division, located in St. Louis, Missouri, during the period of December 27, 1979 through March 8, 1980. Sulfur dioxide (SO/sub 2/) and oxygen (O/sub 2/) concentrations were measured on a dry basis concurrently at both the inlet and outlet of the FGD system controlling the exhaust from one coal-fired boiler. Before commencing the monitoring program the analyzers were subjected to draft Performance Specification Tests (PST) delineated in 40 CFR 60 Appendix B, PST 2 and 3 proposed revisions, October 10, 1979. Throughout the 30-day program, abbreviated accuracy tests were conducted for both SO/sub 2/ and O/sub 2/ monitors and complete accuracy tests were conducted at the conclusion of the program. During the 30-day program, three simultaneous Method 5 particulate tests were conducted at the scrubber inlet and outlet. Component failure and electrical problems delayed the start date for monitoring from January 1, 1980 until February 3, 1980. Once these problems were rectified, the conditioning period was completed and the 30 days of data collection was begun. The report is contained in three volumes. Volume I is a compilation of the following: description of the combustion unit; description of the FGD system; description of monitoring data and process data acquisition, and data reduction; description of the monitoring program; description of the PSTs; results and conclusion of the PST and particulate tests; and quality assurance procedures.

  5. Dose fractionated gamma knife radiosurgery for large arteriovenous malformations on daily or alternate day schedule outside the linear quadratic model: Proof of concept and early results. A substitute to volume fractionation.

    Science.gov (United States)

    Mukherjee, Kanchan Kumar; Kumar, Narendra; Tripathi, Manjul; Oinam, Arun S; Ahuja, Chirag K; Dhandapani, Sivashanmugam; Kapoor, Rakesh; Ghoshal, Sushmita; Kaur, Rupinder; Bhatt, Sandeep

    2017-01-01

    To evaluate the feasibility, safety and efficacy of dose fractionated gamma knife radiosurgery (DFGKRS) on a daily schedule beyond the linear quadratic (LQ) model, for large volume arteriovenous malformations (AVMs). Between 2012-16, 14 patients of large AVMs (median volume 26.5 cc) unsuitable for surgery or embolization were treated in 2-3 of DFGKRS sessions. The Leksell G frame was kept in situ during the whole procedure. 86% (n = 12) patients had radiologic evidence of bleed, and 43% (n = 6) had presented with a history of seizures. 57% (n = 8) patients received a daily treatment for 3 days and 43% (n = 6) were on an alternate day (2 fractions) regimen. The marginal dose was split into 2 or 3 fractions of the ideal prescription dose of a single fraction of 23-25 Gy. The median follow up period was 35.6 months (8-57 months). In the three-fraction scheme, the marginal dose ranged from 8.9-11.5 Gy, while in the two-fraction scheme, the marginal dose ranged from 11.3-15 Gy at 50% per fraction. Headache (43%, n = 6) was the most common early postoperative complication, which was controlled with short course steroids. Follow up evaluation of at least three years was achieved in seven patients, who have shown complete nidus obliteration in 43% patients while the obliteration has been in the range of 50-99% in rest of the patients. Overall, there was a 67.8% reduction in the AVM volume at 3 years. Nidus obliteration at 3 years showed a significant rank order correlation with the cumulative prescription dose (p 0.95, P value 0.01), with attainment of near-total (more than 95%) obliteration rates beyond 29 Gy of the cumulative prescription dose. No patient receiving a cumulative prescription dose of less than 31 Gy had any severe adverse reaction. In co-variate adjusted ordinal regression, only the cumulative prescription dose had a significant correlation with common terminology criteria for adverse events (CTCAE) severity (P value 0.04), independent of age, AVM volume

  6. 2006 Global Demilitarization Symposium Volume 1 Presentations

    Science.gov (United States)

    2006-05-04

    in demil cost based upon trend over last 20 years General Trend: Big bang, small buck to no bang, big buck- Deferring demil will cause us to pay more...They force depots to store new production in less than optimal locations • They cause less than optimal storage workarounds Fact: As storage...thought EPA 2006 “Drinking Water Equivalent Level” and “Cleanup Guidance” = 24.5 ppb Perchlorate used to treat hyperthyroidism since 1950s – >70,000 ppb

  7. Volúmetro com câmaras comunicantes: apresentação de um protótipo de dimensões reduzidas desenvolvido para a avaliação objetiva do volume de mão Volumeter with communicating chambers: presentation of a prototype with reduced dimensions developed for objective assessment of hand volume

    Directory of Open Access Journals (Sweden)

    Rogério Mendonça de Carvalho

    2010-06-01

    Full Text Available A volumetria tradicional por deslocamento de água, que utiliza o princípio do transbordamento de Arquimedes, é considerada o padrão-ouro da avaliação do volume de membros, porém tem seu uso rotineiro prescindido por apresentar uma série de desvantagens: o método é embaraçoso ao paciente, pouco prático e desprovido de higiene, além de consumir muito tempo do examinador. Este artigo apresenta o protótipo de um aparelho inédito que utiliza o princípio dos vasos comunicantes de Pascal para a avaliação direta do volume de mão.Traditional water displacement volumetry, based on Archimedes' principle of buoyancy, is considered the gold-standard for limb volume measurement. However, the routine use of this technique is associated with a series of disadvantages: the method is cumbersome to the patient, messy and unhygienic, and it takes a great amount of the examiner's time. This article presents the prototype of a new piece of equipment designed according to Pascal's principle of communicating vases for the direct evaluation of hand volume.

  8. [Literature review and presentation of our own research results regarding the effects on bone of tyrosine kinase inhibitors imatinib and nilotinib used in the treatment of oncohematological diseases].

    Science.gov (United States)

    Kirschner, Gyöngyi; Balla, Bernadett; Kósa, János; Horváth, Péter; Kövesdi, Andrea; Lakatos, Gergely; Takács, István; Nagy, Zsolt; Tóbiás, Bálint; Árvai, Kristóf; Lakatos, Péter

    2016-09-01

    Tyrosine kinase inhibitors are widely used for treatment of certain oncohematological diseases. Several clinical studies have confirmed that specific BCR-ABL tyrosine kinase inhibitors alter the physiological process of bone tissue in a complex and unclearly identified manner. Since these treatments are being given to more and more patients, and the therapy takes decades or lasts even lifelong, it is justifiable to obtain more detailed knowledge of the molecular background of these mechanisms. In this article the authors summarize preliminary research results and human clinical observations on imatinib and nilotinib which are related to bone metabolism, and present the results of their own experiments in in vitro osteoblast cultures. Based on the presented results, the effects of imatinib and nilotinib on bone cells depend on the concentration of imatinib and nilotinib, the maturation stage of the cells and the distribution ratio of receptor tyrosine kinase signaling pathways. In this study the authors firstly prepared a stop-gap, comprehensive review in the Hungarian literature, regarding the effects of tyrosine kinase inhibitors on bone metabolism. In addition they firstly performed whole transcriptome analysis on osteoblasts in order to obtain a better understanding of the cellular molecular mechanisms. Orv. Hetil., 2016, 157(36), 1429-1437.

  9. The Cool ISM in Elliptical Galaxies. II. Gas Content in the Volume - Limited Sample and Results from the Combined Elliptical and Lenticular Surveys

    CERN Document Server

    Welch, Gary A; Young, Lisa M

    2010-01-01

    We report new observations of atomic and molecular gas in a volume limited sample of elliptical galaxies. Combining the elliptical sample with an earlier and similar lenticular one, we show that cool gas detection rates are very similar among low luminosity E and SO galaxies but are much higher among luminous S0s. Using the combined sample we revisit the correlation between cool gas mass and blue luminosity which emerged from our lenticular survey, finding strong support for previous claims that the molecular gas in ellipticals and lenticulars has different origins. Unexpectedly, however, and contrary to earlier claims, the same is not true for atomic gas. We speculate that both the AGN feedback and merger paradigms might offer explanations for differences in detection rates, and might also point towards an understanding of why the two gas phases could follow different evolutionary paths in Es and S0s. Finally we present a new and puzzling discovery concerning the global mix of atomic and molecular gas in ear...

  10. Seroprevalence of Borrelia burgdorferi in Horses Presented for Coggins Testing in Southwest Virginia and Change in Positive Test Results Approximately 1 Year Later.

    Science.gov (United States)

    Funk, R A; Pleasant, R S; Witonsky, S G; Reeder, D S; Werre, S R; Hodgson, D R

    2016-07-01

    Lyme disease can affect people, dogs, and horses, but it remains poorly understood, especially in the horse. Determining the seroprevalence of Borrelia burgdorferi in horses in different geographic areas will enable better understanding of the epidemiology of the disease, thus improving diagnosis and treatment of affected animals. To determine the seroprevalence of B. burgdorferi in horses in southwest Virginia. Horses presented for routine Coggins testing from January 2013 to January 2014 had additional blood drawn for Lyme Multiplex Assay testing. Of 492 samples collected, 250 samples were analyzed using the Lyme Multiplex Assay. Of the 83 horses that had positive test results to at least 1 outer surface protein (Osp), 63 were available for follow-up testing 5-17 months later (June 2014). Thirty-three percent of horses had positive results for antibodies to at least 1 Osp. Horses with a positive outer surface protein F (OspF) result were older (14.5 ± 0.79) than horses with a negative OspF result (11.6 ± 0.53). Of the horses available for follow-up testing, 63% had the same result as that of the initial test. There was no difference in test result between initial and follow-up testing. Horses seropositive to B. burgdorferi are common in Virginia, and older horses are more likely to have a positive test result for OspF than younger horses. Follow-up testing indicated that the majority of horses that were positive on initial testing did not have a different test result 5-17 months later. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  11. The application of large volume airgun sources to the onshore-offshore seismic surveys: implication of the experimental results in northern South China Sea

    Institute of Scientific and Technical Information of China (English)

    QIU XueLin; CHEN Yong; ZHU RiXiang; XU HuiLong; SHI XiaoBin; YE ChunMing; ZHAO MingHui; XIA ShaoHong

    2007-01-01

    Onshore-offshore seismic experiments were carried out for the first time in northern South China Sea using large volume airgun sources at sea and seismic stations on land. The experimental results indicate that seismic signals from the new airgun array of R/V Shiyan 2 can be detected as far as 255 km. The signal effective area reaches nearly 50000 km2, which covers Hong Kong and Pearl River Delta. Compared with the old airgun array, the signal amplitude, propagation distance and effective area of the new airgun array have been increased notably, which demonstrates that the upgrade of the airgun source was successful. Comparisons with previous experimental results in other regions show that the shooting effect of the new airgun array is similar to those best airgun sources in the world. Especially, it is a new breakthrough in using the permanent seismic stations onshore to record long distance airgun signals offshore, which has great significance to the realization of the "seismic radar" concept and the 3D seismic surveys of crustal structure in coastal areas.

  12. Seeing and feeling volumes: The influence of shape on volume perception.

    Science.gov (United States)

    Kahrimanovic, Mirela; Bergmann Tiest, Wouter M; Kappers, Astrid M L

    2010-07-01

    The volume of common objects can be perceived visually, haptically or by a combination of both senses. The present study shows large effects of the object's shape on volume perception within all these modalities, with an average bias of 36%. In all conditions, the volume of a tetrahedron was overestimated compared to that of a cube or a sphere, and the volume of a cube was overestimated compared to that of a sphere. Additional analyses revealed that the biases could be explained by the dependence of the volume judgment on different geometric properties. During visual volume perception, the strategies depended on the objects that were compared and they were also subject-dependent. However, analysis of the haptic and bimodal data showed more consistent results and revealed that surface area of the stimuli influenced haptic as well as bimodal volume perception. This suggests that bimodal volume perception is more influenced by haptic input than by visual information.

  13. CERN Library | Tord Ekelöf presents the proceedings of the Nobel Symposium on the Higgs Boson Discovery and Other Recent LHC Results | 12 June

    CERN Multimedia

    2014-01-01

    Thursday, 12 June 2014 at 16:00 in the Library (52-1-052).   The “Nobel Symposium on LHC results” took place at Krusenberg mansion, Uppsala, Sweden on 13-17 May 2013. The aim of the Symposium was to give an overview of the latest experimental and theoretical results pertaining to the LHC programme but also to give an occasion to ponder over the implications of these results in the broader context of the past, present and future evolution of the field of Particle Physics. “Nobel Symposium 154: The Higgs Boson Discovery and Other Recent LHC Results”, ed. by Tord Ekelöf, Physica Scripta T154, IOP, 2013, ISBN 9789789789781. * Coffee will be served from 15:30 * E-proceedings available here.

  14. Sparse PDF Volumes for Consistent Multi-Resolution Volume Rendering

    KAUST Repository

    Sicat, Ronell Barrera

    2014-12-31

    This paper presents a new multi-resolution volume representation called sparse pdf volumes, which enables consistent multi-resolution volume rendering based on probability density functions (pdfs) of voxel neighborhoods. These pdfs are defined in the 4D domain jointly comprising the 3D volume and its 1D intensity range. Crucially, the computation of sparse pdf volumes exploits data coherence in 4D, resulting in a sparse representation with surprisingly low storage requirements. At run time, we dynamically apply transfer functions to the pdfs using simple and fast convolutions. Whereas standard low-pass filtering and down-sampling incur visible differences between resolution levels, the use of pdfs facilitates consistent results independent of the resolution level used. We describe the efficient out-of-core computation of large-scale sparse pdf volumes, using a novel iterative simplification procedure of a mixture of 4D Gaussians. Finally, our data structure is optimized to facilitate interactive multi-resolution volume rendering on GPUs.

  15. Sparse PDF Volumes for Consistent Multi-Resolution Volume Rendering.

    Science.gov (United States)

    Sicat, Ronell; Krüger, Jens; Möller, Torsten; Hadwiger, Markus

    2014-12-01

    This paper presents a new multi-resolution volume representation called sparse pdf volumes, which enables consistent multi-resolution volume rendering based on probability density functions (pdfs) of voxel neighborhoods. These pdfs are defined in the 4D domain jointly comprising the 3D volume and its 1D intensity range. Crucially, the computation of sparse pdf volumes exploits data coherence in 4D, resulting in a sparse representation with surprisingly low storage requirements. At run time, we dynamically apply transfer functions to the pdfs using simple and fast convolutions. Whereas standard low-pass filtering and down-sampling incur visible differences between resolution levels, the use of pdfs facilitates consistent results independent of the resolution level used. We describe the efficient out-of-core computation of large-scale sparse pdf volumes, using a novel iterative simplification procedure of a mixture of 4D Gaussians. Finally, our data structure is optimized to facilitate interactive multi-resolution volume rendering on GPUs.

  16. Volume of a doubly truncated hyperbolic tetrahedron

    CERN Document Server

    Kolpakov, Alexander

    2012-01-01

    The present paper regards the volume function of a doubly truncated hyperbolic tetrahedron. Starting from the previous results of J. Murakami, U. Yano and A. Ushijima, we have developed a unified approach to expressing the volume in different geometric cases by dilogarithm functions and to treat properly the many analytic strata of the latter. Finally, several numeric examples are given.

  17. Use of procalcitonin for the diagnosis of pneumonia in patients presenting with a chief complaint of dyspnoea: results from the BACH (Biomarkers in Acute Heart Failure) trial

    Science.gov (United States)

    Maisel, Alan; Neath, Sean-Xavier; Landsberg, Judd; Mueller, Christian; Nowak, Richard M.; Peacock, W. Frank; Ponikowski, Piotr; Möckel, Martin; Hogan, Christopher; Wu, Alan H.B.; Richards, Mark; Clopton, Paul; Filippatos, Gerasimos S.; Di Somma, Salvatore; Anand, Inder; Ng, Leong L.; Daniels, Lori B.; Christenson, Robert H.; Potocki, Mihael; McCord, James; Terracciano, Garret; Hartmann, Oliver; Bergmann, Andreas; Morgenthaler, Nils G.; Anker, Stefan D.

    2012-01-01

    Aims Biomarkers have proven their ability in the evaluation of cardiopulmonary diseases. We investigated the utility of concentrations of the biomarker procalcitonin (PCT) alone and with clinical variables for the diagnosis of pneumonia in patients presenting to emergency departments (EDs) with a chief complaint of shortness of breath. Methods and results The BACH trial was a prospective, international, study of 1641 patients presenting to EDs with dyspnoea. Blood samples were analysed for PCT and other biomarkers. Relevant clinical data were also captured. Patient outcomes were assessed at 90 days. The diagnosis of pneumonia was made using strictly validated guidelines. A model using PCT was more accurate [area under the curve (AUC) 72.3%] than any other individual clinical variable for the diagnosis of pneumonia in all patients, in those with obstructive lung disease, and in those with acute heart failure (AHF). Combining physician estimates of the probability of pneumonia with PCT values increased the accuracy to >86% for the diagnosis of pneumonia in all patients. Patients with a diagnosis of AHF and an elevated PCT concentration (>0.21 ng/mL) had a worse outcome if not treated with antibiotics (P = 0.046), while patients with low PCT values (<0.05 ng/mL) had a better outcome if they did not receive antibiotic therapy (P = 0.049). Conclusion Procalcitonin may aid in the diagnosis of pneumonia, particularly in cases with high diagnostic uncertainty. Importantly, PCT may aid in the decision to administer antibiotic therapy to patients presenting with AHF in which clinical uncertainty exists regarding a superimposed bacterial infection. Trial registration: NCT00537628 PMID:22302662

  18. Psychological and personality factors in type 2 diabetes mellitus, presenting the rationale and exploratory results from The Maastricht Study, a population-based cohort study

    DEFF Research Database (Denmark)

    van Dooren, Fleur E P; Denollet, Johan; Verhey, Frans R J

    2016-01-01

    BACKGROUND: Strong longitudinal evidence exists that psychological distress is associated with a high morbidity and mortality risk in type 2 diabetes. Little is known about the biological and behavioral mechanisms that may explain this association. Moreover, the role of personality traits...... in these associations is still unclear. In this paper, we first describe the design of the psychological part of The Maastricht Study that aims to elucidate these mechanisms. Next, we present exploratory results on the prevalence of depression, anxiety and personality traits in type 2 diabetes. Finally, we briefly....... Personality traits were measured by the DS14 and Big Five personality questionnaires. Type 2 diabetes was assessed by an oral glucose tolerance test. Logistic regression analyses were used to estimate the associations of depression, anxiety and personality with type 2 diabetes, adjusted for age, sex...

  19. Results and summary of voting among the audience during presentation and discussion of Medullary Thyroid Carcinoma clinical guidelines prepared by American Thyroid Association.

    Science.gov (United States)

    Feldt-Rasmussen, Ulla; Soderstrom, Folke

    2013-03-14

    The one-day ETA-CRN meeting, preceding the ETA meeting in Lisbon, was planned in advance to provide a thorough assessment of the European response to the published American Thyroid Association MTC guidelines. During the meeting, following each of the European speakers, a series of questions, related to the specific aspect, were presented to the audience. The responses from the audience were collected by an AudioResponseSystem (ARS voting system). The results of the voting showed in summary that European expert opinion leaders and an audience of specialists in treatment of Medullary Carcinoma welcomes the American Guidelines on the management of MTC, but simultaneously only partially agrees with some of the statements in the guidelines.

  20. The Nainital-Cape Survey -- II:Report for pulsation in five chemically peculiar A-type stars and presentation of 140 null results

    CERN Document Server

    Joshi, S; Martínez, P; Kurtz, D W; Girish, V; Seetha, S; Sagar, R; Ashoka, B N; Joshi, Santosh; Martinez, Peter; Sagar, Ram

    2006-01-01

    To search photometric variability in chemically peculiar A type stars in the northern hemisphere. High-speed photometric observations of Ap and Am star candidates have been carried out from ARIES (Manora Peak, Nainital) using a three-channel fast photometer attached to the ARIES 104-cm Sampurnanand telescope. This paper presents three new variables: HD 113878, HD 118660 and HD 207561. During the time span of the survey (1999 December to 2004 January) pulsations of the $\\delta$ Sct type were also found for the two evolved Am stars HD 102480 and HD 98851, as reported in Joshi et al. (2002, 2003). Additionally, we present 140 null results of the survey for this time span. The star HD 113878 pulsates with a period of 2.31 hr, which is typical of $\\delta$ Sct stars. HD 118660 exhibits multi-periodic variability with a prominent period of nearly 1 hr. These periods need to be investigated and make HD 118660 a particularly interesting target for further observations. For HD 207561, a star classified as Am, a probabl...

  1. Burn Injuries Resulting from Hot Water Bottle Use: A Retrospective Review of Cases Presenting to a Regional Burns Unit in the United Kingdom

    Directory of Open Access Journals (Sweden)

    Shehab Jabir

    2013-01-01

    Full Text Available Introduction. Hot water bottles are commonly used to relieve pain and for warmth during the colder months of the year. However, they pose a risk of serious burn injuries. The aim of this study is to retrospectively review all burn injuries caused by hot water bottles presenting to our regional burns unit. Methods. Patients with burns injuries resulting from hot water bottle use were identified from our burns database between the periods of January 2004 and March 2013 and their cases notes reviewed retrospectively. Results. Identified cases involved 39 children (aged 17 years or younger and 46 adults (aged 18 years or older. The majority of burns were scald injuries. The mean %TBSA was 3.07% (SD ± 3.40. Seven patients (8.24% required debridement and skin grafting while 3 (3.60% required debridement and application of Biobrane. One patient (1.18% required local flap reconstruction. Spontaneous rupture accounted for 48.20% of injuries while accidental spilling and contact accounted for 33% and 18.80% of injuries, respectively. The mean time to heal was 28.87 days (SD ± 21.60. Conclusions. This study highlights the typical distribution of hot water bottle burns and the high rate of spontaneous rupture of hot water bottles, which have the potential for significant burn injuries.

  2. Conservative treatment of idiopathic scoliosis according to FITS concept: presentation of the method and preliminary, short term radiological and clinical results based on SOSORT and SRS criteria

    Science.gov (United States)

    2011-01-01

    Background Conservative scoliosis therapy according to the FITS Concept is applied as a unique treatment or in combination with corrective bracing. The aim of the study was to present author's method of diagnosis and therapy for idiopathic scoliosis FITS-Functional Individual Therapy of Scoliosis and to analyze the early results of FITS therapy in a series of consecutive patients. Methods The analysis comprised separately: (1) single structural thoracic, thoracolumbar or lumbar curves and (2) double structural scoliosis-thoracic and thoracolumbar or lumbar curves. The Cobb angle and Risser sign were analyzed at the initial stage and at the 2.8-year follow-up. The percentage of patients improved (defined as decrease of Cobb angle of more than 5 degrees), stable (+/- 5 degrees), and progressed (increase of Cobb angle of more than 5 degrees) was calculated. The clinical assessment comprised: the Angle of Trunk Rotation (ATR) initial and follow-up value, the plumb line imbalance, the scapulae level and the distance from the apical spinous process of the primary curve to the plumb line. Results In the Group A: (1) in single structural scoliosis 50,0% of patients improved, 46,2% were stable and 3,8% progressed, while (2) in double scoliosis 50,0% of patients improved, 30,8% were stable and 19,2% progressed. In the Group B: (1) in single scoliosis 20,0% of patients improved, 80,0% were stable, no patient progressed, while (2) in double scoliosis 28,1% of patients improved, 46,9% were stable and 25,0% progressed. Conclusion Best results were obtained in 10-25 degrees scoliosis which is a good indication to start therapy before more structural changes within the spine establish. PMID:22122964

  3. Conservative treatment of idiopathic scoliosis according to FITS concept: presentation of the method and preliminary, short term radiological and clinical results based on SOSORT and SRS criteria

    Directory of Open Access Journals (Sweden)

    Białek Marianna

    2011-11-01

    Full Text Available Abstract Background Conservative scoliosis therapy according to the FITS Concept is applied as a unique treatment or in combination with corrective bracing. The aim of the study was to present author's method of diagnosis and therapy for idiopathic scoliosis FITS-Functional Individual Therapy of Scoliosis and to analyze the early results of FITS therapy in a series of consecutive patients. Methods The analysis comprised separately: (1 single structural thoracic, thoracolumbar or lumbar curves and (2 double structural scoliosis-thoracic and thoracolumbar or lumbar curves. The Cobb angle and Risser sign were analyzed at the initial stage and at the 2.8-year follow-up. The percentage of patients improved (defined as decrease of Cobb angle of more than 5 degrees, stable (+/- 5 degrees, and progressed (increase of Cobb angle of more than 5 degrees was calculated. The clinical assessment comprised: the Angle of Trunk Rotation (ATR initial and follow-up value, the plumb line imbalance, the scapulae level and the distance from the apical spinous process of the primary curve to the plumb line. Results In the Group A: (1 in single structural scoliosis 50,0% of patients improved, 46,2% were stable and 3,8% progressed, while (2 in double scoliosis 50,0% of patients improved, 30,8% were stable and 19,2% progressed. In the Group B: (1 in single scoliosis 20,0% of patients improved, 80,0% were stable, no patient progressed, while (2 in double scoliosis 28,1% of patients improved, 46,9% were stable and 25,0% progressed. Conclusion Best results were obtained in 10-25 degrees scoliosis which is a good indication to start therapy before more structural changes within the spine establish.

  4. Aperiodic Volume Optics

    Science.gov (United States)

    Gerke, Tim D.

    Presented in this thesis is an investigation into aperiodic volume optical devices. The three main topics of research and discussion are the aperiodic volume optical devices that we call computer-generated volume holograms (CGVH), defects within periodic 3D photonic crystals, and non-periodic, but ordered 3D quasicrystals. The first of these devices, CGVHs, are designed and investigated numerically and experimentally. We study the performance of multi-layered amplitude computer-generated volume holograms in terms of efficiency and angular/frequency selectivity. Simulation results show that such aperiodic devices can increase diffraction efficiency relative to periodic amplitude volume holograms while maintaining angular and wavelength selectivity. CGVHs are also designed as voxelated volumes using a new projection optimization algorithm. They are investigated using a volumetric diffraction simulation and a standard 3D beam propagation technique as well as experimentally. Both simulation and experiment verify that the structures function according to their design. These represent the first diffractive structures that have the capacity for generating arbitrary transmission and reflection wave fronts and that provide the ability for multiplexing arbitrary functionality given different illumination conditions. Also investigated and discussed in this thesis are 3D photonic crystals and quasicrystals. We demonstrate that these devices can be fabricated using a femtosecond laser direct writing system that is particularly appropriate for fabrication of such arbitrary 3D structures. We also show that these devices can provide 3D partial bandgaps which could become complete bandgaps if fabricated using high index materials or by coating lower index materials with high index metals. Our fabrication method is particularly suited to the fabrication of engineered defects within the periodic or quasi-periodic systems. We demonstrate the potential for fabricating defects within

  5. Metabolic Tumor Volume as a Prognostic Imaging-Based Biomarker for Head-and-Neck Cancer: Pilot Results From Radiation Therapy Oncology Group Protocol 0522

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, David L., E-mail: david.schwartz@utsw.edu [Department of Radiation Oncology, University of Texas Southwestern School of Medicine, Dallas, Texas (United States); Harris, Jonathan [Radiation Therapy Oncology Group Statistical Center, Philadelphia, Pennsylvania (United States); Yao, Min [Department of Radiation Oncology, Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Rosenthal, David I. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Opanowski, Adam; Levering, Anthony [American College of Radiology Imaging Network, Philadelphia, Pennsylvania (United States); Ang, K. Kian [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Trotti, Andy M. [Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida (United States); Garden, Adam S. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Jones, Christopher U. [Sutter Medical Group, Sacramento, California (United States); Harari, Paul [Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin (United States); Foote, Robert [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Holland, John [Department of Radiation Medicine, Oregon Health & Science University, Portland, Oregon (United States); Zhang, Qiang [Radiation Therapy Oncology Group Statistical Center, Philadelphia, Pennsylvania (United States); Le, Quynh-Thu [Department of Radiation Oncology, Stanford University School of Medicine, Palo Alto, California (United States)

    2015-03-15

    Purpose: To evaluate candidate fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) imaging biomarkers for head-and-neck chemoradiotherapy outcomes in the cooperative group trial setting. Methods and Materials: Radiation Therapy Oncology Group (RTOG) protocol 0522 patients consenting to a secondary FDG-PET/CT substudy were serially imaged at baseline and 8 weeks after radiation. Maximum standardized uptake value (SUVmax), SUV peak (mean SUV within a 1-cm sphere centered on SUVmax), and metabolic tumor volume (MTV) using 40% of SUVmax as threshold were obtained from primary tumor and involved nodes. Results: Of 940 patients entered onto RTOG 0522, 74 were analyzable for this substudy. Neither high baseline SUVmax nor SUVpeak from primary or nodal disease were associated with poor treatment outcomes. However, primary tumor MTV above the cohort median was associated with worse local-regional control (hazard ratio 4.01, 95% confidence interval 1.28-12.52, P=.02) and progression-free survival (hazard ratio 2.34, 95% confidence interval 1.02-5.37, P=.05). Although MTV and T stage seemed to correlate (mean MTV 6.4, 13.2, and 26.8 for T2, T3, and T4 tumors, respectively), MTV remained a strong independent prognostic factor for progression-free survival in bivariate analysis that included T stage. Primary MTV remained prognostic in p16-associated oropharyngeal cancer cases, although sample size was limited. Conclusion: High baseline primary tumor MTV was associated with worse treatment outcomes in this limited patient subset of RTOG 0522. Additional confirmatory work will be required to validate primary tumor MTV as a prognostic imaging biomarker for patient stratification in future trials.

  6. Association between hospital procedure volume and early complications after pacemaker implantation: results from a large, unselected, contemporary cohort of the German nationwide obligatory external quality assurance programme.

    Science.gov (United States)

    Nowak, Bernd; Tasche, Karl; Barnewold, Linda; Heller, Günther; Schmidt, Boris; Bordignon, Stefano; Chun, K R Julian; Fürnkranz, Alexander; Mehta, Rajendra H

    2015-05-01

    Several studies demonstrated an inverse relationship between cardioverter-defibrillator implantation volume and complication rates, suggesting better outcomes for higher volume centres. However, the association of institutional procedural volume with patient outcomes for permanent pacemaker (PPM) implantation remains less known, especially in decentralized implantation systems. We performed retrospective examination of data on patients undergoing PPM from the German obligatory quality assurance programme (2007-12) to evaluate the relationship of hospital PPM volume (categorized into quintiles of their mean annual volume) with risk-adjusted in-hospital surgical complications (composite of pneumothorax, haemothorax, pericardial effusion, or pocket haematoma, all requiring intervention, or device infection) and pacemaker lead dislocation. Overall 430 416 PPM implantations were documented in 1226 hospitals. Systems included dual (72.8%) and single (25.8%) chamber PPM and cardiac resynchronization therapy (CRT) devices (1.1%). Complications included surgical (0.92%), and ventricular (0.99%), and atrial (1.22%) lead dislocation. Despite an increase in relatively complex procedures (dual chamber, CRT), there was a significant decrease in the procedural and fluoroscopy times and complications from lowest to highest implantation volume quintiles (P for trend <0.0001). The greatest difference was observed between the lowest (1-50 implantations/year-reference group) and the second-lowest (51-90 implantations/year) quintile: surgical complications [odds ratio (OR) 0.69; confidence interval (CI) 0.60-0.78], atrial lead dislocations (OR 0.69; CI 0.59-0.80), and ventricular lead dislocations (OR 0.73; CI 0.63-0.84). Hospital annual PPM volume was directly related to indication-based implantation of relatively more complex PPM and yet inversely with procedural times and rates of early surgical complications and lead dislocations. Thus, our data suggest better performance and lower

  7. Thermal-hydraulic characteristics of a Westinghouse Model 51 steam generator. Volume 2. Appendix A, numerical results. Interim report. [CALIPSOS code numerical data

    Energy Technology Data Exchange (ETDEWEB)

    Fanselau, R.W.; Thakkar, J.G.; Hiestand, J.W.; Cassell, D.

    1981-03-01

    The Comparative Thermal-Hydraulic Evaluation of Steam Generators program represents an analytical investigation of the thermal-hydraulic characteristics of four PWR steam generators. The analytical tool utilized in this investigation is the CALIPSOS code, a three-dimensional flow distribution code. This report presents the steady state thermal-hydraulic characteristics on the secondary side of a Westinghouse Model 51 steam generator. Details of the CALIPSOS model with accompanying assumptions, operating parameters, and transport correlations are identified. Comprehensive graphical and numerical results are presented to facilitate the desired comparison with other steam generators analyzed by the same flow distribution code.

  8. High volume data storage architecture analysis

    Science.gov (United States)

    Malik, James M.

    1990-01-01

    A High Volume Data Storage Architecture Analysis was conducted. The results, presented in this report, will be applied to problems of high volume data requirements such as those anticipated for the Space Station Control Center. High volume data storage systems at several different sites were analyzed for archive capacity, storage hierarchy and migration philosophy, and retrieval capabilities. Proposed architectures were solicited from the sites selected for in-depth analysis. Model architectures for a hypothetical data archiving system, for a high speed file server, and for high volume data storage are attached.

  9. Reduced central blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik; Bendtsen, Flemming; Sørensen, T I

    1989-01-01

    for measuring the central blood volume. We have developed a method that enables us to determine directly the central blood volume, i.e., the blood volume in the heart cavities, lungs, and central arterial tree. In 60 patients with cirrhosis and 16 control subjects the central blood volume was assessed according...... flow, or sequestration of fluid in the peritoneal cavity, or any combination thereof. The present results indicate that central circulatory underfilling is an integral part of the hemodynamic and homeostatic derangement observed in cirrhosis....

  10. Movement Disorder Society-sponsored revision of the Unified Parkinson's Disease Rating Scale (MDS-UPDRS): scale presentation and clinimetric testing results.

    Science.gov (United States)

    Goetz, Christopher G; Tilley, Barbara C; Shaftman, Stephanie R; Stebbins, Glenn T; Fahn, Stanley; Martinez-Martin, Pablo; Poewe, Werner; Sampaio, Cristina; Stern, Matthew B; Dodel, Richard; Dubois, Bruno; Holloway, Robert; Jankovic, Joseph; Kulisevsky, Jaime; Lang, Anthony E; Lees, Andrew; Leurgans, Sue; LeWitt, Peter A; Nyenhuis, David; Olanow, C Warren; Rascol, Olivier; Schrag, Anette; Teresi, Jeanne A; van Hilten, Jacobus J; LaPelle, Nancy

    2008-11-15

    We present a clinimetric assessment of the Movement Disorder Society (MDS)-sponsored revision of the Unified Parkinson's Disease Rating Scale (MDS-UPDRS). The MDS-UDPRS Task Force revised and expanded the UPDRS using recommendations from a published critique. The MDS-UPDRS has four parts, namely, I: Non-motor Experiences of Daily Living; II: Motor Experiences of Daily Living; III: Motor Examination; IV: Motor Complications. Twenty questions are completed by the patient/caregiver. Item-specific instructions and an appendix of complementary additional scales are provided. Movement disorder specialists and study coordinators administered the UPDRS (55 items) and MDS-UPDRS (65 items) to 877 English speaking (78% non-Latino Caucasian) patients with Parkinson's disease from 39 sites. We compared the two scales using correlative techniques and factor analysis. The MDS-UPDRS showed high internal consistency (Cronbach's alpha = 0.79-0.93 across parts) and correlated with the original UPDRS (rho = 0.96). MDS-UPDRS across-part correlations ranged from 0.22 to 0.66. Reliable factor structures for each part were obtained (comparative fit index > 0.90 for each part), which support the use of sum scores for each part in preference to a total score of all parts. The combined clinimetric results of this study support the validity of the MDS-UPDRS for rating PD.

  11. RHUM-RUM, a Large-Scale Effort to Seismologically Image a Mantle Plume Under the Reunion Hotspot: Experiment Presentation and Initial Results

    Science.gov (United States)

    Sigloch, K.; Barruol, G.

    2014-12-01

    RHUM-RUM is a German-French geophysical experiment based on the seafloor and on islands surrounding the hotspot of La Réunion, western Indian Ocean. Its primary objective is to clarify the presence or absence of a mantle plume beneath the Reunion hotspot, which is thought to have first pierced the surface 65 million years ago with the eruption of the Deccan Traps on India. RHUM-RUM's central component is a one-year deployment (Oct 2012 - Nov 2013) of 57 broadband ocean-bottom seismometers (OBS) and hydrophones on an area of 2000x2000 km2 surrounding the hotspot. All OBS have been successfully recovered. We also have been operating 37 land seismometers on the islands of La Réunion, Mauritius, Rodrigues, southern Seychelles, îles Eparses, and on Madagascar between 2011 and 2014. As the data collection stage is drawing to a close, we discuss data yield and quality with respect to RHUM-RUM's primary purpose (passive seismological imaging through all depth levels of the mantle) and secondary applications ("environmental seismology" in a sparsely instrumented area, e.g., tracking of tropical cyclones). We give an overview of the research questions investigated by the RHUM-RUM group, and present preliminary results.

  12. VOLUMNECT: measuring volumes with Kinect

    Science.gov (United States)

    Quintino Ferreira, Beatriz; Griné, Miguel; Gameiro, Duarte; Costeira, João. Paulo; Sousa Santos, Beatriz

    2014-03-01

    This article presents a solution to volume measurement object packing using 3D cameras (such as the Microsoft KinectTM). We target application scenarios, such as warehouses or distribution and logistics companies, where it is important to promptly compute package volumes, yet high accuracy is not pivotal. Our application auto- matically detects cuboid objects using the depth camera data and computes their volume and sorting it allowing space optimization. The proposed methodology applies to a point cloud simple computer vision and image processing methods, as connected components, morphological operations and Harris corner detector, producing encouraging results, namely an accuracy in volume measurement of 8mm. Aspects that can be further improved are identified; nevertheless, the current solution is already promising turning out to be cost effective for the envisaged scenarios.

  13. Color-coded perfused blood volume imaging using multidetector CT: initial results of whole-brain perfusion analysis in acute cerebral ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Kloska, Stephan P.; Fischer, Tobias; Fischbach, Roman; Heindel, Walter [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Nabavi, Darius G.; Dittrich, Ralf; Ringelstein, E.B. [University of Muenster, Department of Neurology, Muenster (Germany); Ditt, Hendrik; Klotz, Ernst [Siemens AG, Medical Solutions, Forchheim (Germany)

    2007-09-15

    Computed tomography (CT) is still the primary imaging modality following acute stroke. To evaluate a prototype of software for the calculation of color-coded whole-brain perfused blood volume (PBV) images from CT angiography (CTA) and nonenhanced CT (NECT) scans, we studied 14 patients with suspected acute ischemia of the anterior cerebral circulation. PBV calculations were performed retrospectively. The detection rate of ischemic changes in the PBV images was compared with NECT. The volume of ischemic changes in PBV was correlated with the infarct volume on follow-up examination taking potential vessel recanalization into account. PBV demonstrated ischemic changes in 12/12 patients with proven infarction and was superior to NECT (8/12) in the detection of early ischemia. Moreover, PBV demonstrated the best correlation coefficient with the follow-up infarct volume (Pearson's R = 0.957; P = 0.003) for patients with proven recanalization of initially occluded cerebral arteries. In summary, PBV appears to be more accurate in the detection of early infarction compared to NECT and mainly visualizes the irreversibly damaged ischemic tissue. (orig.)

  14. Is there a correlation between operative results and change in ventricular volume after shunt placement? A study of 60 cases of idiopathic normal-pressure hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Meier, U.; Graewe, A.; Hajdukova, A. [Department of Neurosurgery, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683, Berlin (Germany); Paris, S.; Stockheim, D.; Mutze, S. [Department of Radiology, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683, Berlin (Germany)

    2003-06-01

    In patients with communicating or normal-pressure hydrocephalus, ventricular volume decreases following implantation of differential pressure valves. We implanted hydrostatic (Miethke dual-switch) valves in 60 patients with normal-pressure hydrocephalus (NPH) between September 1997 and December 2001. The patients underwent CT 1 year after operation, and we measured the Evans index. Although 83% of the patients showed no change in ventricular volume as assessed by this index, 72% nevertheless showed good to excellent and 16% satisfactory clinical improvement, while 12% showed no improvement. Moderate or marked reduction in ventricular size was observed in 17%, of whom 40% of these patients showed good to excellent and 20% satisfactory clinical improvement; 40% showed unsatisfactory improvement. The favourable outcome following implantation of a hydrostatic shunt thus did not correlate with decreased ventricular volume 1 year after operation, better outcomes being observed in patients with little or no alteration in ventricular size than in those with a marked decrease. Postoperative change in ventricular volume in NPH thus does not have the same significance as in patients with high-pressure hydrocephalus. (orig.)

  15. Voting Present

    Directory of Open Access Journals (Sweden)

    James Lo

    2013-12-01

    Full Text Available During his time as a state senator in Illinois, Barack Obama voted “Present” 129 times, a deliberate act of nonvoting that subsequently became an important campaign issue during the 2008 presidential elections. In this article, I examine the use of Present votes in the Illinois state senate. I find evidence that Present votes can largely be characterized as protest votes used as a legislative tool by the minority party. Incorporating information from Present votes into a Bayesian polytomous item-response model, I find that this information increases the efficiency of ideal point estimates by approximately 35%. There is little evidence of significant moderation by Obama when Present votes are accounted for, though my results suggest that Obama’s voting record may have moderated significantly before his subsequent election to the U.S. Senate. My results also suggest that because legislative nonvoting may occur for a variety of reasons, naive inclusion of nonvoting behavior into vote choice models may lead to biased results.

  16. Annual Proceedings of Selected Papers on the Practice of Educational Communications and Technology Presented at the Annual Convention of the Association for Educational Communications and Technology (33rd, Anaheim, California, 2010). Volume 2

    Science.gov (United States)

    Simonson, Michael, Ed.

    2010-01-01

    For the thirty-third year, the Research and Theory Division of the Association for Educational Communications and Technology (AECT) is sponsoring the publication of these Proceedings. This is Volume #2 of the 33rd "Annual Proceedings of Selected Papers on the Practice of Educational Communications and Technology." This volume includes…

  17. Idiopathic infantile arterial calcification in a 12-year-old girl presenting as chronic mesenteric ischemia: imaging findings and angioplasty results

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Edwin; Owen, Richard [University of Alberta, Department of Radiology and Diagnostic Imaging, Edmonton (Canada); Bruce, Garth [University of Saskatchewan, Department of Pediatrics, Royal University Hospital, Saskatoon (Canada); Wiebe, Sheldon [University of Saskatchewan, Department of Medical Imaging, Royal University Hospital, Saskatoon (Canada)

    2011-11-15

    We report an unusual case of chronic mesenteric ischemia presenting in a 12-year-old girl with idiopathic infantile arterial calcinosis (IIAC). This is the first reported case in the literature of chronic mesenteric ischemia in the setting of IIAC. The girl presented with a classical history of postprandial abdominal pain. Imaging demonstrated significant stenoses of the celiac axis, superior mesenteric artery (SMA) and inferior mesenteric artery (IMA). Angioplasty of the celiac axis and SMA was attempted, with successful dilation of the SMA only. At 3-, 6- and 12-month follow-ups, the child's symptoms had almost resolved. This case report has three important ramifications: chronic mesenteric ischemia is a possible clinical presentation in children with IACC, pre-angioplasty imaging is important in guiding treatment approach, and angioplasty was effective in this case of chronic mesenteric ischemia and offers hope for other similarly affected children. (orig.)

  18. Final report on the Background Soil Characterization Project at the Oak Ridge Reservation, Oak Ridge, Tennessee. Volume 1: Results of Field Sampling Program

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, D.R.; Ammons, J.T.; Branson, J.L. [and others

    1993-10-01

    This report presents, evaluates, and documents data and results obtained in the Background Soil Characterization Project (BSCP). It is intended to be a stand-alone document for application and use in structuring and conducting remedial investigation and remedial action projects in the Environmental Restoration (ER) Program. The objectives of the BSCP consist of the following: determine background concentrations of organics, metals, and radionuclides in natural soils that are key to environmental restoration projects; provide remediation projects with 100% validated data on background concentrations, which are technically and legally defensible; and quantify baseline risks from background constituents for comparison of risks associated with contaminated sites.

  19. Clinical presentation and course of bleeding events in patients with venous thromboembolism, treated with apixaban or enoxaparin and warfarin. Results from the AMPLIFY trial.

    Science.gov (United States)

    Bleker, Suzanne M; Cohen, Alexander T; Büller, Harry R; Agnelli, Giancarlo; Gallus, Alexander S; Raskob, Gary E; Weitz, Jeffrey I; Curto, Madelyn; Sisson, Melanie; Middeldorp, Saskia

    2016-11-30

    Apixaban, a direct acting oral anticoagulant (DOAC), was found to be non-inferior to and safer as enoxaparin followed by warfarin for treatment of venous thromboembolism (VTE) in the AMPLIFY trial. Information is needed on how bleeding events with DOACs present and develop. In this post-hoc analysis, the clinical presentation and course of all major and clinically relevant non major (CRNM) bleeding events in the AMPLIFY trial were blindly classified by three investigators, using pre-designed classification schemes containing four categories. Odds ratios (OR) for classifying as category three or four (representing a more severe clinical presentation and course) were calculated between apixaban and enoxaparin/warfarin. In total, 63 major and 311 CRNM bleeding events were classified. Of the major bleeds, a more severe clinical presentation occurred in 28.5 % of apixaban versus 44.9 % of enoxaparin/warfarin related recipients (OR 0.49, 95 % confidence interval [CI] 0.14-1.78). A severe clinical course was observed in 14.3 % and in 12.2 %, respectively (OR 1.19, 95 %CI 0.21-6.69). Of the CRNM bleeding events, a more severe clinical presentation and extent of clinical care was found in 25 % of apixaban recipients compared to 22.7 % in the enoxaparin/warfarin group (OR 1.13, 95 %CI 0.65-1.97). The clinical presentation and course of major and CRNM bleeds were similar in apixaban and enoxaparin/warfarin treated patients. This finding should reassure physicians and patients that even in the absence of a specific reversal agent, apixaban is a convenient and safe choice for VTE.

  20. Frequency and correlates of late presentation for HIV infection in France: older adults are a risk group - results from the ANRS-VESPA2 Study, France.

    Science.gov (United States)

    Wilson, Kayigan d'Almeida; Dray-Spira, Rosemary; Aubrière, Cindy; Hamelin, Christine; Spire, Bruno; Lert, France

    2014-01-01

    Correlates of late presentation (LP) for HIV infection in Metropolitan France and French overseas departments (FODs) were assessed among HIV-infected patients recently diagnosed, using data from a large cross-sectional survey, representative of the French HIV-infected population, conducted in 2011. LP was defined as presentation with either clinical AIDS events within the calendar year of diagnosis or CD4 France and FODs. In Metropolitan France, 47.7% of participants were late presenters and 29.3% presented with advanced disease. LP was more frequent among male and female migrants from sub-Saharan Africa (SSA; 58.5% and 56.4%) and non-African heterosexual males (61.8%) than among men who have sex with men (34.8%). In FODs, 53.2% of participants were late presenters and 36.8% presented with an advanced disease. LP was more frequent among men than women (60.6% vs. 45.3%) and among those with a lower level of education (56.6% vs. 47.5%). A consistent positive association was found in adjusted analyses between LP/PAD and increasing age at diagnosis among all subpopulations, in both settings. In Metropolitan France, among men who have sex with men, those self-declaring as bisexual were at higher risk of LP/PAD; among non-African heterosexual males and females, religiosity was associated with increased risk of LP/PAD; and among SSA migrants, those diagnosed within the year following their arrival in France were at higher risk of LP/PAD. Older age at diagnosis is a major risk factor for LP/PAD independently of any other socio-demographic characteristics. Promotion of HIV testing should be renewed to target each subgroup at risk while paying a particular attention to middle-aged or older adults whose attitudes and beliefs towards HIV/AIDS might prevent them from seeking testing.

  1. The alteration of gray matter volume in children with mental retardation: the differences between the patients presented with operation deficit predominantly and those presented with language deficit mainly%采用优化的基于体素的形态测量学方法研究不同类型智力障碍患儿脑灰质容积的变化

    Institute of Scientific and Technical Information of China (English)

    袁新宇; 肖江喜; 蒋学祥; 金春华; 张远超; 白振华; 仪晓立

    2012-01-01

    Objective To detect the differences of grey matter volume between the patients with mental retardation (MR) presented clinically as operation deficit (OD) or as language deficit (LD) and the children with typical normal development using optimal VBM.The developmental connections between brain gray matter and language or operation skills were examined.Methods Magnetic resonance imaging was obtained from 9 children with mental retardation presented as OD predominantly and 11 children with mental retardation presented as LD mainly,as well as the age-matched control group (11 and 14 normal children,respectively) on a 1.5 T scanner.Voxel-based morphometry analysis with an optimization of spatial segmentation and normalization procedures was applied to compare the volume of grey matter between the two groups (OD VS.control; LD VS.control).Statistically,the total and local gray matter volumes were compared between the two groups with t test.Results The total gray matter volume of OD group was [(1.030 ± 0.078) × 106 mm3].Compared to that of controls [(0.984 ± 0.058) × 106 mm3],it was increased significantly (t =-2.6,P < 0.05).And the gray matter volume in the posterior cingulated gyrus,left superior prefrontal gyrus,left cuneus,left middle prefrontal gyrus and the body of left caudate nucleus showed significantly increased.Meanwhile,the total gray matter volume of the MR children presented as LD [(1.002 ± 0.068) × 106 mm3] showed significantly increased(t =-3.0,P < 0.05) compared with that of control group [(0.957 ±0.057) × 106 mm3].The gray matter volume in bilateral thalami,the left inferior temporal gyrus,the left inferior frontal gyrus,and the left cerebellum of the LD group was more than that of normal children.Conclusion As revealed by VBM,there are differences in alterations of gray matter volume between MR children presented with OD and with LD relative to control.%目的 利用优化的基于体素的脑形态学分析法(VBM),分别比较以操作缺

  2. Reports from dissemination and feed-back workshops with presentation of Volante results from WP1 and WP2, and response from local, regional, and national stakeholders

    DEFF Research Database (Denmark)

    Frederiksen, Pia; Vesterager, Jens Peter; Kristensen, Søren Bech Pilgaard;

    2014-01-01

    The report constitutes an overview of the dissemination and feed-back workshops in the Volante case study countries: Netherlands, Romania, Austria, Greece and Denmark. The workshops were conducted based on the presentation of findings from WP1 and WP2 to national, regional and local stakeholders...

  3. Factors associated with presenting late or with advanced HIV disease in the Netherlands, 1996 2014: Results from a national observational cohort

    NARCIS (Netherlands)

    E.L.M. Op de Coul (Eline); A. Van Sighem (Ard); K. Brinkman; B.H.B. van Benthem (B. H B); M.E. van der Ende (Marchina); S. Geerlings (Suzanne); P. Reiss (Peter); J.M. Prins (Jan); T.W. Kuijpers (Taco W.); H.J. Scherpbier; J.T.M. van der Meer (J. T M); F. Wit (Ferdinand); M.H. Godfried; P. Reiss (Peter); T. van der Poll (Tom); F.J.B. Nellen (F. J B); S.E. Geerlings (Suzanne); M. Van Vugt; D. Pajkrt (Dasja); J.C. Bos (Jeannet); W.J. Wiersinga; M. van der Valk (Marc); A. Goorhuis (Abraham); J.W.R. Hovius (Joppe); J. Van Eden; A. Henderiks; A.M.H. Van Hes; M. Mutschelknauss; H.E. Nobel; F.J.J. Pijnappel; A.M. Westerman; S. Jurriaans (Suzanne); N. Back (Nicole); H.L. Zaaijer (Hans); B. Berkhout; M. Cornelissen (Marion); C.J. Schinkel; X.V. Thomas; A. De Ruyter Ziekenhuis (Admiraal); M. Van Den Berge; A. Stegeman; S. Baas; L.H. De Looff (L. Hage); D. Versteeg; C. Ziekenhuis (Catharina); M.J.H. Pronk; H.S.M. Ammerlaan (Heidi); E.M.H.M. Korsten-Vorstermans; E.S. De Munnik; J. Tjhie; M.C.A. Wegdam; E. Kinderziekenhuis (Emma); A.M. Weijsenfeld; M.E. van der Ende (Marchina); T.E.M.S. de Vriessluijs (Theodora); E.C.M. van Gorp (Eric); C.A.M. Schurink (Carolina); J.L. Nouwen (Jan); A. Verbon (Annelies); B.J.A. Rijnders (Bart); H.I. Bax; R.J. Hassing (Robert); M. van der Feltz; N. Bassant; J.E.A. Van Beek; M. Vriesde; L. van Zonneveld (Laura); A. De Oude-Lubbers; H.J. Van Den Berg-Cameron; F.B. Bruinsma-Broekman; J. De Groot; M. De Zeeuw-De Man; M.J. Broekhoven-Kruijne; M. Schutten (Martin); A.D.M.E. Osterhaus (Albert); C.A.B. Boucher; G.J.A. Driessen (Gertjan); A.M.C. van Rossum (Annemarie); L. van der Knaap (Linda); E. Visser; J. Branger; C.J.H.M. Duijf-Van De Ven; H. Ziekenhuis (Haga); D. Haag (Den); E.F. Schippers (Emile F); C. van Nieuwkoop (C.); R.W. Brimicombe (R.); J.M. VanJperen; G. Van Der Hut; P.F.H. Franck; A. van Eeden (A.); M. Groot; I.S. Kwa; I. Klinieken (Isala); J.W. Bouwhuis (Jolande); A.G.W. Van Hulzen; P.C.J. Bor; P. Bloembergen (Peter); M.J.H.M. Wolfhagen; G. Ruijs (G.); K. Gasthuis (Kennemer); R. Soetekouw (R.); L.M.M. Van Der Prijt; M. Schoemaker; W.A. Van Der Reijden; R. Jansen; B.L. Herpers; F.P. Kroon; S.M. Arend (Sandra); M.G.J. de Boer (Mark); M.P. Bauer; A. Jolink (Albert); A. Vollaard (Albert); C. Moons; A.C.M. Kroes (Aloys C.M.); M. Ziekenhuis (Maasstad); K. Pogány (Katalin); J.V. Smit; E. Smit; T. Van Niekerk; O. Pontesilli (Oscar); A.O. Lashof (A. Oude); D. Posthouwer (Dirk); J. Schippers; R. Vergoossen; I.H. Loo; M.C. Zuiderzee; R. El Moussaoui; G. van Twillert (Gitte); J.W.T.C. Stuart (James W.T.Cohen); B.M.W. Diederen; F.A. Van Truijen-Oud; R. Jansen; L.B.S. Gelinck (Luc); C. Meerkerk; G.S. Wildenbeest; C.L. Jansen; D.P.F. Van Houte; S. Faber; C.E. Delsing; H. Heins; P.H.J. Frissen; W.L. Blok (Willem); W.E.M. Schouten; G.E.L. van den Berk (Guido); C.J. Brouwer; G.F. Geerders; K. Hoeksema; M.J. Kleene; I.B. Van Der Meché; A.J.M. Toonen; S. Wijnands; M. Keuter (Monique); A.J.A.M. van der Ven (André); H.T. Hofstede (Hjm Ter); A.S.M. Dofferhoff; R. van Crevel (Reinout); M.E.W. Bosch; K.J.T. Grintjes-Huisman; B.J. Zomer; J.P. van der Berg; E.H. Gisolf (Elisabeth); P.H.M. Van Bentum; N. Langebeek (Nienke); C.M.A. Swanink; K.D. Lettinga; H. Sulman; E. Witte; B.C. Vrouenraets (Bart); F.N. Lauw; H. Paap; D.J. Vlasblom; A.W. Rosingh; A.E. Brouwer; M. Kuipers; R.M.W.J. Santegoets (R. M W J); B. Van Der Ven; A.G.M. Buiting (Anton); P.J. Kabel; H.G. Sprenger (Herman); E.H. Schölvinck; S. van Assen; K.R. Wilting; Y. Stienstra; P.A. Van Der Meulen; D.A. De Weerd; A. Riezebos-Brilman (Annelies); C. Van Leer-Buter (Coretta); M.M.E. Schneider (Margriet M.); T. Mudrikova (Tania Tania); P.M. Ellerbroek (P.); J.J. Oosterheert (Jan Jelrik); J.E. Arends (Joop); R.E. Barth; M.W.M. Wassenberg; L.M. Laan; E.E.B. Van Oers-Hazelzet; J. Patist; S.C.J.M. Vervoort (Sigrid C. J. M.); R. Frauenfelder; F. Verduyn-Lunel; A.M.J. Wensing (Annemarie); M.A. Agtmael (Michiel); R.M. Perenboom; M. Bomers; J. De Vocht; C.M.J.E. Vandenbroucke-Grauls (Christina); C.W. Ang; T.F.W. Wolfs (Tom); L.J. Bont; L.A. Gras (Luuk); A.I. van Sighem (Ard); C. Smit (Colette); M.M.J. Hillebregt (Mariska); V. Kimmel; Y. Tong; R. Van Den Boogaard; P. Hoekstra; A. De Lang; M. Berkhout; S. Grivell; A. Jansen; M. van den Akker (Marjan); D. Bergsma; C. Lodewijk; R. Meijering; B. Peeck; M. Raethke; C. Ree; R. Regtop; Y. Ruijs; M. Schoorl; E. Tuijn; L. Veenenberg; T. Woudstra; Y. Bakker; A. De Jong; M. Broekhoven; E. Claessen; M.J. Rademaker; L. Munjishvili; E. Kruijne

    2016-01-01

    textabstractObjectives: Early testing for HIV and entry into care are crucial to optimise treatment outcomes of HIV-infected patients and to prevent spread of HIV. We examined risk factors for presentation with late or advanced disease in HIV-infected patients in the Netherlands. Methods: HIV-infect

  4. Evaluation of sampling plans for in-service inspection of steam generator tubes. Volume 2, Comprehensive analytical and Monte Carlo simulation results for several sampling plans

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, R.J.; Heasler, P.G.; Baird, D.B. [Pacific Northwest Lab., Richland, WA (United States)

    1994-02-01

    This report summarizes the results of three previous studies to evaluate and compare the effectiveness of sampling plans for steam generator tube inspections. An analytical evaluation and Monte Carlo simulation techniques were the methods used to evaluate sampling plan performance. To test the performance of candidate sampling plans under a variety of conditions, ranges of inspection system reliability were considered along with different distributions of tube degradation. Results from the eddy current reliability studies performed with the retired-from-service Surry 2A steam generator were utilized to guide the selection of appropriate probability of detection and flaw sizing models for use in the analysis. Different distributions of tube degradation were selected to span the range of conditions that might exist in operating steam generators. The principal means of evaluating sampling performance was to determine the effectiveness of the sampling plan for detecting and plugging defective tubes. A summary of key results from the eddy current reliability studies is presented. The analytical and Monte Carlo simulation analyses are discussed along with a synopsis of key results and conclusions.

  5. Different Web Credibility Assessment as a Result of One Year Difference in Education. A Study on the Dimensions of Credibility of Commercial Presentation Websites

    Directory of Open Access Journals (Sweden)

    Oana ŢUGULEA

    2015-12-01

    Full Text Available This study is based on the hypothesis that one year of study difference between students underlines different evaluations of the dimensions of commercial presentation websites’ credibility. The objectives of this study are: (- highlighting significant differences of credibility dimensions evaluation between second and third year of study students; (- highlighting the dimensions considered to be important by the second year of study students; (- highlighting the dimensions considered to be important by the third year of study students. For presentation commercial Websites, as approached by this study, second year of study students consider “site-user connection” and “information support” as important dimensions; for the same category of Websites, third year of study students consider “ease of use”, “real world feel” and “site-etiquette” as important dimensions.

  6. Seroprevalence of Borrelia burgdorferi in Horses Presented for Coggins Testing in Southwest Virginia and Change in Positive Test Results Approximately 1 Year Later

    OpenAIRE

    Funk, R.A.; Pleasant, R.S.; Witonsky, S.G.; Reeder, D.S.; Werre, S.R.; Hodgson, D. R.

    2016-01-01

    Background Lyme disease can affect people, dogs, and horses, but it remains poorly understood, especially in the horse. Determining the seroprevalence of Borrelia burgdorferi in horses in different geographic areas will enable better understanding of the epidemiology of the disease, thus improving diagnosis and treatment of affected animals. Hypothesis To determine the seroprevalence of B. burgdorferi in horses in southwest Virginia. Animals Horses presented for routine Coggins testing from J...

  7. SeaWiFS technical report series. Volume 26: Results of the SeaWiFS Data Analysis Round-Robin, July 1994 (DARR-1994)

    Science.gov (United States)

    Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Siegel, David A.; Obrien, Margaret C.; Sorensen, Jen C.; Konnoff, Daniel A.; Brody, Eric A.; Mueller, James L.; Davis, Curtiss O.; Rhea, W. Joseph

    1995-01-01

    The accurate determination of upper ocean apparent optical properties (AOP's) is essential for the vicarious calibration of the sea-viewing wide field-of-view sensor (SeaWiFS) instrument and the validation of the derived data products. To evaluate the role that data analysis methods have upon values of derived AOP's, the first Data Analysis Round-Robin (DARR-94) workshop was sponsored by the SeaWiFS Project during 21-23 July, 1994. The focus of this intercomparison study was the estimation of the downwelling irradiance spectrum just beneath the sea surface, E(sub d)(0(sup -), lambda); the upwelling nadir radiance just beneath the sea surface, L(sub u)(0(sup -), lambda); and the vertical profile of the diffuse attenuation coefficient spectrum, K(sub d)(z, lambda). In the results reported here, different methodologies from four research groups were applied to an identical set of 10 spectroradiometry casts in order to evaluate the degree to which data analysis methods influence AOP estimation, and whether any general improvements can be made. The overall results of DARR-94 are presented in Chapter 1 and the individual methods of the four groups are presented in Chapters 2-5. The DARR-94 results do not show a clear winner among data analysis methods evaluated. It is apparent, however, that some degree of outlier rejection is required in order to accurately estimate L(sub u)(0(sup -), lambda) or E(sub d)(0(sup -), lambda). Furthermore, the calculation, evaluation and exploitation of confidence intervals for the AOP determinations needs to be explored. That is, the SeaWiFS calibration and validation problem should be recast in statistical terms where the in situ AOP values are statistical estimates with known confidence intervals.

  8. A Rotational Crofton Formula for Flagged Intrinsic Volumes of Sets of Positive Reach

    DEFF Research Database (Denmark)

    Auneau, Jeremy Michel

    A rotational Crofton formula is derived relating the flagged intrinsic volumes of a compact set of positive reach with the flagged intrinsic volumes measured on sections passing through a fixed point. In particular cases, the flagged intrinsic volumes defined in the present paper are identical...... to the classical intrinsic volumes. The tight connection between our main result and other recent rotational integral formulae involving intrinsic volumes is pointed out....

  9. Performance and efficacy of 320-row computed tomography coronary angiography in patients presenting with acute chest pain: results from a clinical registry.

    Science.gov (United States)

    van Velzen, J E; de Graaf, F R; Kroft, L J; de Roos, A; Reiber, J H C; Bax, J J; Jukema, J W; Schuijf, J D; Schalij, M J; van der Wall, E E

    2012-04-01

    The purpose of this study was to evaluate the performance of 320-row computed tomography angiography (CTA) in the identification of significant coronary artery disease (CAD) in patients presenting with acute chest pain and to examine the relation to outcome during follow-up. A total of 106 patients with acute chest pain underwent CTA to evaluate presence of CAD. Each CTA was classified as: normal, non-significant CAD (unstable angina requiring revascularization. Among the 106 patients, 23 patients (22%) had a normal CTA, 19 patients (18%) had non-significant CAD on CTA, 59 patients (55%) had significant CAD on CTA, and 5 patients (5%) had non-diagnostic image quality. In total, 16 patients (15%) were immediately discharged after normal CTA and 90 patients (85%) underwent invasive coronary angiography. Sensitivity, specificity, and positive and negative predictive values to detect significant CAD on CTA were 100, 87, 93, and 100%, respectively. During mean follow-up of 13.7 months, no cardiovascular events occurred in patients with a normal CTA examination. In patients with non-significant CAD on CTA, no cardiac death or myocardial infarctions occurred and only 1 patient underwent revascularization due to unstable angina. In patients presenting with acute chest pain, an excellent clinical performance for the non-invasive assessment of significant CAD was demonstrated using CTA. Importantly, normal or non-significant CAD on CTA predicted a low rate of adverse cardiovascular events and favorable outcome during follow-up.

  10. Heightened Vagal Activity during High-Calorie Food Presentation in Obese compared with Non-obese Individuals - Results of a Pilot Study

    Science.gov (United States)

    Udo, Tomoko; Weinberger, Andrea H.; Grilo, Carlos M.; Brownell, Kelly D.; DiLeone, Ralph J.; Lampert, Rachel; Matlin, Samantha L.; Yanagisawa, Katherine; McKee, Sherry A.

    2013-01-01

    Summary Eating behaviors are highly cue-dependent. Changes in mood states and exposure to palatable food both increase craving and consumption of food. Vagal activity supports adaptive modulation of physiological arousal and has an important role in cue-induced appetitive behaviors. Using high-frequency heart rate variability (HF HRV), this preliminary study compared vagal activity during positive and negative mood induction, and presentation of preferred high-calorie food items between obese (n = 12; BMI ≥ 30) and non-obese individuals (n = 14; 18.5 < BMI < 30). Participants completed two laboratory sessions (negative vs. positive mood conditions). Following 3-hours of food deprivation, all participants completed a mood induction, and then were exposed to their preferred high-calorie food items. HF HRV was assessed throughout. Obese and non-obese individuals were not significantly different in HF HRV during positive or negative mood induction. Obese individuals showed significantly greater levels of HF HRV during presentation of their preferred high-calorie food items than non-obese individuals, particularly in the positive mood condition. This is the first study to demonstrate increased vagal activity in response to food cues in obese individuals compared with non-obese individuals. Our findings warrant further investigation on the potential role of vagally-mediated cue reactivity in overeating and obesity. PMID:24847667

  11. Heightened vagal activity during high-calorie food presentation in obese compared with non-obese individuals--results of a pilot study.

    Science.gov (United States)

    Udo, Tomoko; Weinberger, Andrea H; Grilo, Carlos M; Brownell, Kelly D; DiLeone, Ralph J; Lampert, Rachel; Matlin, Samantha L; Yanagisawa, Katherine; McKee, Sherry A

    2014-01-01

    Eating behaviours are highly cue-dependent. Changes in mood states and exposure to palatable food both increase craving and consumption of food. Vagal activity supports adaptive modulation of physiological arousal and has an important role in cue-induced appetitive behaviours. Using high-frequency heart rate variability (HF HRV), this preliminary study compared vagal activity during positive and negative mood induction, and presentation of preferred high-calorie food items between obese (n = 12; BMI ≥ 30) and non-obese individuals (n = 14; 18.5 < BMI < 30). Participants completed two laboratory sessions (negative vs. positive mood conditions). Following 3-h of food deprivation, all participants completed a mood induction, and then were exposed to their preferred high-calorie food items. HF HRV was assessed throughout. Obese and non-obese individuals were not significantly different in HF HRV during positive or negative mood induction. Obese individuals showed significantly greater levels of HF HRV during presentation of their preferred high-calorie food items than non-obese individuals, particularly in the positive mood condition. This is the first study to demonstrate increased vagal activity in response to food cues in obese individuals compared with non-obese individuals. Our findings warrant further investigation on the potential role of vagally-mediated cue reactivity in overeating and obesity. © 2014 Asian Oceanian Association for the Study of Obesity . Published by Elsevier Ltd. All rights reserved.

  12. Second generation pressurized fluidized-bed combustion (PFBC) research and development, Phase 2 -- Task 4, carbonizer testing. Volume 1, Test results

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, R.; Robertson, A.; Vanhook, J.; Goyal, A.; Rehmat, A.; Newby, R.

    1994-11-01

    During the period beginning November 1991 and ending September 1992, a series of tests were conducted at Foster Wheeler Development Corporation in a fluidized-bed coal carbonizer to determine its performance characteristics. The carbonizer was operated for 533 hours in a jetting fluidized-bed configuration during which 36 set points (steady-state periods) were achieved. Extensive data were collected on the feed and product stream compositions, heating values, temperatures, and flow rates. With these data, elemental and energy balances were computed to evaluate and confirm accuracy of the data. The carbonizer data were not as self-consistent as could be desired (balance closure imperfection). A software package developed by Science Ventures, Inc., of California, called BALAID, was used to reconcile the carbonizer data; the details of the reconciliation have been given in Volume 1 of this report. The reconciled data for the carbonizer were rigorously analyzed, correlations were developed, and the model was updated accordingly. The model was then used in simulating each of the 36 steady-state periods achieved in the pilot plant. The details are given in this Volume of the report.

  13. Does Cytoreductive Prostatectomy Really Have an Impact on Prognosis in Prostate Cancer Patients with Low-volume Bone Metastasis? Results from a Prospective Case-Control Study.

    Science.gov (United States)

    Steuber, Thomas; Berg, Kasper D; Røder, Martin A; Brasso, Klaus; Iversen, Peter; Huland, Hartwig; Tiebel, Anne; Schlomm, Thorsten; Haese, Alexander; Salomon, Georg; Budäus, Lars; Tilki, Derya; Heinzer, Hans; Graefen, Markus; Mandel, Philipp

    2017-07-08

    The impact of cytoreductive radical prostatectomy (CRP) on oncological outcomes in patients with prostate cancer (PCa) and distant metastases has been demonstrated by retrospective data with their potential selection bias. Using prospective institutional data, we compared the outcomes between 43 PCa patients with low-volume bone metastases (1-3 lesions) undergoing CRP (median follow-up 32.7 mo) and 40 patients receiving best systemic therapy (BST; median follow-up 82.2 mo). The inclusion criteria for both cohorts were identical. So far, no significant difference in castration resistant-free survival (p=0.92) or overall survival (p=0.25) has been detected. Compared to recent reports, the outcomes for our control group are more favorable, indicating a potential selection bias in the previous retrospective studies. Therefore, the unclear oncological effect has to be weighed against the potential risks of CRP. However, patients benefit from a significant reduction in locoregional complications (7.0% vs 35%; p<0.01) when undergoing CRP. In this study we analyzed the impact of surgery in patients with prostate cancer and bone metastases. Using prospective data, we could not show a significant benefit of surgery on survival, but the rate of locoregional complications was lower. Therefore, patients should be treated within prospective trials evaluating the role of cytoreductive prostatectomy in low-volume, bone metastatic prostate cancer. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  14. Insulin gene mutations resulting in early-onset diabetes: marked differences in clinical presentation, metabolic status, and pathogenic effect through endoplasmic reticulum retention

    DEFF Research Database (Denmark)

    Meur, Gargi; Simon, Albane; Harun, Nasret

    2009-01-01

    the molecular mechanisms involved. RESEARCH DESIGN AND METHODS: The INS gene was sequenced in 16 French probands with unexplained MODY, 95 patients with nonautoimmune early-onset diabetes (diagnosed at ... quantitated by real-time PCR. RESULTS: A novel coding mutation, L30M, potentially affecting insulin multimerization, was identified in five diabetic individuals (diabetes onset 17-36 years) in a single family. L30M preproinsulin-GFP fluorescence largely associated with the endoplasmic reticulum (ER) in MIN6...

  15. Midterm results of diagnostic treatment and repair strategy in older patients presenting with nonrestrictive ventricular septal defect and severe pulmonary artery hypertension

    Institute of Scientific and Technical Information of China (English)

    Liu Aijun; Li Zhiqiang; Li Xiaofeng; Fan Xiangming; Su Junwu; Zhang Jing; He Yan

    2014-01-01

    Background Congenital heart disease with severe pulmonary arterial hypertension (SPAH),previously thought to have irreversible pulmonary vascular disease (PVD),has been recently successfully corrected using diagnostic treatment and repair strategy by our surgery team.This study aimed to evaluate the midterm results of a selected cohort of older patients with nonrestrictive ventricular septal defect (VSD) and SPAH using diagnostic treatment and repair strategy.Methods The records of 56 patients older than six years with nonrestrictive VSD and SPAH undergoing diagnostic treatment and repair strategy from 2006 to 2012 were retrospectively reviewed.All patients received advanced pulmonary arterial hypertension (PAH) therapy and radical repairs were performed when transcutaneous oxygen saturation (SPO2) increased up to 93%.Results There were no operative deaths.SPO2 and baseline six-minute walk test (SMWT) distance of all selected patients increased significantly and mean pulmonary artery pressure (MPAP) regressed significantly after diagnostic treatment and at late follow-up (P <0.01).The incidence of late postoperative PAH was seen in six (10.7%) patients and by Logistic regression analysis,early postoperative PAH was an independent risk factor related to late postoperative PAH.Conclusions Diagnostic treatment and repair strategy was effective and safe for treatment of nonrestrictive VSD and SPAH and the midterm results were excellent.Diagnostic treatment strategy was effective in assessing the reversibility of SPAH in older patients associated with nonrestrictive VSD and the PVD in these selective patients is generally reversible.

  16. Variable volume combustor

    Energy Technology Data Exchange (ETDEWEB)

    Ostebee, Heath Michael; Ziminsky, Willy Steve; Johnson, Thomas Edward; Keener, Christopher Paul

    2017-01-17

    The present application provides a variable volume combustor for use with a gas turbine engine. The variable volume combustor may include a liner, a number of micro-mixer fuel nozzles positioned within the liner, and a linear actuator so as to maneuver the micro-mixer fuel nozzles axially along the liner.

  17. Risk factors and outcomes for late presentation for HIV-positive persons in Europe: results from the Collaboration of Observational HIV Epidemiological Research Europe Study (COHERE.

    Directory of Open Access Journals (Sweden)

    Amanda Mocroft

    Full Text Available BACKGROUND: Few studies have monitored late presentation (LP of HIV infection over the European continent, including Eastern Europe. Study objectives were to explore the impact of LP on AIDS and mortality. METHODS AND FINDINGS: LP was defined in Collaboration of Observational HIV Epidemiological Research Europe (COHERE as HIV diagnosis with a CD4 count <350/mm(3 or an AIDS diagnosis within 6 months of HIV diagnosis among persons presenting for care between 1 January 2000 and 30 June 2011. Logistic regression was used to identify factors associated with LP and Poisson regression to explore the impact on AIDS/death. 84,524 individuals from 23 cohorts in 35 countries contributed data; 45,488 were LP (53.8%. LP was highest in heterosexual males (66.1%, Southern European countries (57.0%, and persons originating from Africa (65.1%. LP decreased from 57.3% in 2000 to 51.7% in 2010/2011 (adjusted odds ratio [aOR] 0.96; 95% CI 0.95-0.97. LP decreased over time in both Central and Northern Europe among homosexual men, and male and female heterosexuals, but increased over time for female heterosexuals and male intravenous drug users (IDUs from Southern Europe and in male and female IDUs from Eastern Europe. 8,187 AIDS/deaths occurred during 327,003 person-years of follow-up. In the first year after HIV diagnosis, LP was associated with over a 13-fold increased incidence of AIDS/death in Southern Europe (adjusted incidence rate ratio [aIRR] 13.02; 95% CI 8.19-20.70 and over a 6-fold increased rate in Eastern Europe (aIRR 6.64; 95% CI 3.55-12.43. CONCLUSIONS: LP has decreased over time across Europe, but remains a significant issue in the region in all HIV exposure groups. LP increased in male IDUs and female heterosexuals from Southern Europe and IDUs in Eastern Europe. LP was associated with an increased rate of AIDS/deaths, particularly in the first year after HIV diagnosis, with significant variation across Europe. Earlier and more widespread testing

  18. Investigation of difficult component effects on finite element model vibration prediction for the Bell AH-1G helicopter. Volume 1: Ground vibration test results

    Science.gov (United States)

    Dompka, R. V.

    1989-01-01

    Under the NASA-sponsored Design Analysis Methods for VIBrationS (DAMVIBS) program, a series of ground vibration tests and NASTRAN finite element model (FEM) correlations were conducted on the Bell AH-1G helicopter gunship to investigate the effects of difficult components on the vibration response of the airframe. Previous correlations of the AH-1G showed good agreement between NASTRAN and tests through 15 to 20 Hz, but poor agreement in the higher frequency range of 20 to 30 Hz. Thus, this effort emphasized the higher frequency airframe vibration response correlations and identified areas that need further R and T work. To conduct the investigations, selected difficult components (main rotor pylon, secondary structure, nonstructural doors/panels, landing gear, engine, fuel, etc.) were systematically removed to quantify their effects on overall vibratory response of the airframe. The entire effort was planned and documented, and the results reviewed by NASA and industry experts in order to ensure scientific control of the testing, analysis, and correlation exercise. In particular, secondary structure and damping had significant effects on the frequency response of the airframe above 15 Hz. Also, the nonlinear effects of thrust stiffening and elastomer mounts were significant on the low frequency pylon modes below main rotor 1p (5.4 Hz). The results of the ground vibration testing are presented.

  19. Comparing oncology clinical programs by use of innovative designs and expected net present value optimization: Which adaptive approach leads to the best result?

    Science.gov (United States)

    Parke, Tom; Marchenko, Olga; Anisimov, Vladimir; Ivanova, Anastasia; Jennison, Christopher; Perevozskaya, Inna; Song, Guochen

    2017-01-01

    Designing an oncology clinical program is more challenging than designing a single study. The standard approaches have been proven to be not very successful during the last decade; the failure rate of Phase 2 and Phase 3 trials in oncology remains high. Improving a development strategy by applying innovative statistical methods is one of the major objectives of a drug development process. The oncology sub-team on Adaptive Program under the Drug Information Association Adaptive Design Scientific Working Group (DIA ADSWG) evaluated hypothetical oncology programs with two competing treatments and published the work in the Therapeutic Innovation and Regulatory Science journal in January 2014. Five oncology development programs based on different Phase 2 designs, including adaptive designs and a standard two parallel arm Phase 3 design were simulated and compared in terms of the probability of clinical program success and expected net present value (eNPV). In this article, we consider eight Phase2/Phase3 development programs based on selected combinations of five Phase 2 study designs and three Phase 3 study designs. We again used the probability of program success and eNPV to compare simulated programs. For the development strategies, we considered that the eNPV showed robust improvement for each successive strategy, with the highest being for a three-arm response adaptive randomization design in Phase 2 and a group sequential design with 5 analyses in Phase 3.

  20. Present and future connection of Asian-Pacific Oscillation to large-scale atmospheric circulations and East Asian rainfall: results of CMIP5

    Science.gov (United States)

    Zhou, Botao; Xu, Ying; Shi, Ying

    2017-03-01

    The summer Asian-Pacific oscillation (APO), one of the major modes of climate variability over the Asian-Pacific sector, has a pronounced effect on variations of large-scale atmospheric circulations and climate. This study evaluated the capability of 30 state-of-the-art climate models among the Coupled Model Intercomparison Project Phase 5 (CMIP5) in simulating its association with the atmospheric circulations over the Asian-Pacific region and the precipitation over East Asia. Furthermore, their future connections under the RCP8.5 scenario were examined. The evaluation results show that 5 out of 30 climate models can well capture the observed APO-related features in a comprehensive way, including the strengthened South Asian high (SAH), deepened North Pacific trough (NPT) and northward East Asian jet (EAJ) in the upper troposphere; an intensification of the Asian low and the North Pacific subtropical high (NPSH) as well as a northward shift of the western Pacific subtropical high (WPSH) in the lower troposphere; and a decrease in East Asian summer rainfall (EASR) under the positive APO phase. Based on the five CMIP5 models' simulations, the dynamic linkages of the APO to the SAH, NPT, AL, and NPSH are projected to maintain during the second half of the twenty-first century. However, its connection with the EASR tends to reduce significantly. Such a reduction might result from the weakening of the linkage of the APO to the meridional displacement of the EAJ and WPSH as a response to the warming scenario.

  1. Optical mammography: a new technique for visualizing breast lesions in women presenting non palpable BIRADS 4-5 imaging findings: preliminary results with radiologic-pathologic correlation.

    Science.gov (United States)

    Athanasiou, Alexandra; Vanel, Daniel; Fournier, Laure; Balleyguier, Corinne

    2007-02-28

    The purpose of this prospective study is to determine the diagnostic accuracy of near-infrared breast optical absorption imaging in patients with Breast Imaging Reporting and Data System (BIRADS) 4-5 non-palpable lesions scheduled for biopsy, using pathology after core or excisional biopsy as a reference. The patient's breast was positioned onto a panel of red light-emitting diodes (640 nm). A soft membrane was inflated to exert a uniform pressure on the breast. Transmitted light was detected using a CCD camera. The entire acquisition sequence took 1 minute. Image processing generated dynamic images displayed in colour scale, to reveal time-dependent changes in the transmitted light intensity caused by the pressure change. Dynamic curves were classified in two categories: consistently decreasing intensity suspicious for malignancy, and sinusoidal increasing intensity considered as benign. Seventy-eight women consulting for non-palpable breast lesions were initially included in the study. An imaging-histology correlation was obtained for seventy-two patients, the remaining six patients were excluded for technical optical scan reasons. We experienced an overall sensitivity of 73% and specificity of 38%, the false negative results being mainly small size (<10 mm) infiltrating malignant lesions and ductal carcinoma in situ (DCIS). False positive results were seen in benign proliferative lesions. Dynamic optical breast imaging is a novel, low-cost, non-invasive technique yielding a new type of information about the physiology of breast lesions. Absorption is due to haemoglobin and its products, therefore reflecting the angiogenic status of breast tumours.

  2. Optical mammography: a new technique for visualizing breast lesions in women presenting non palpable BIRADS 4–5 imaging findings: preliminary results with radiologic–pathologic correlation

    Science.gov (United States)

    Vanel, Daniel; Fournier, Laure; Balleyguier, Corinne

    2007-01-01

    The purpose of this prospective study is to determine the diagnostic accuracy of near-infrared breast optical absorption imaging in patients with Breast Imaging Reporting and Data System (BIRADS) 4–5 non-palpable lesions scheduled for biopsy, using pathology after core or excisional biopsy as a reference. The patient's breast was positioned onto a panel of red light-emitting diodes (640 nm). A soft membrane was inflated to exert a uniform pressure on the breast. Transmitted light was detected using a CCD camera. The entire acquisition sequence took 1 minute. Image processing generated dynamic images displayed in colour scale, to reveal time-dependent changes in the transmitted light intensity caused by the pressure change. Dynamic curves were classified in two categories: consistently decreasing intensity suspicious for malignancy, and sinusoidal increasing intensity considered as benign. Seventy-eight women consulting for non-palpable breast lesions were initially included in the study. An imaging–histology correlation was obtained for seventy-two patients, the remaining six patients were excluded for technical optical scan reasons. We experienced an overall sensitivity of 73% and specificity of 38%, the false negative results being mainly small size (<10 mm) infiltrating malignant lesions and ductal carcinoma in situ (DCIS). False positive results were seen in benign proliferative lesions. Dynamic optical breast imaging is a novel, low-cost, non-invasive technique yielding a new type of information about the physiology of breast lesions. Absorption is due to haemoglobin and its products, therefore reflecting the angiogenic status of breast tumours. PMID:17339139

  3. A comparison of results from previous and present investigations of benthic macroinvertebrates in the small and shallow Lake Shoji, Fuji Five Lakes, Japan

    Directory of Open Access Journals (Sweden)

    Kimio Hirabayashi

    2012-10-01

    Full Text Available In order to clarify the current status of the benthic community of Lake Shoji, and to examine the difference with the last quantitative data of the lake by Miyadi (1932 and Kitagawa (1973, the distribution of benthic macroinvertebrates in this lake was studied. Also, a comparison of the benthic fauna and density was made between the present and previous studies, with a discussion concerning the succession of benthic macroinvertebrates in relation to changes in the lake bottom environment. On March 1, 2010, and September 7, 2011, bathymetrical sampling surveys were carried out using a standard Ekman-Birge grab at each of the 7 locations in Lake Shoji. The average densities of the benthic communities for all the stations were 4,107 inds. m-2, comprised principally of oligochaetes 50.2%, chironomids 48.6%, and chaoborid 1.2% in March 2010, whereas in September 2011 the average density was 1,185 inds. m-2, and mostly comprised of oligochaetes 86.6% and chironomids 13.4%. On the other hand, the average biomasses (wet weight of these benthic macroinvertebrates in March 2010 were composed of 33.3% oligochaetes, 62.8% chironomid larvae, and 3.9% chaoborid larvae, as opposed to 48.8% oligochaetes and 51.2% chironomid larvae, respectively, in September 2011. Propsilocerus akamusi (Tokunaga, 1938 and Procladius sp. of chironomid larvae were the dominant species, making up 10.0% and 17.6%, respectively, of the total chironomid fauna in density, and 83.2% and 9.2% in biomass in March 2010. The mean density of P. akamusi was about 2.5 times higher than that reported by Kitagawa in the 1970s. In recent years, the number of P. akamusi larvae has tended to increase; they are widely distributed, and the anoxic-layer and anaerobic-layer are thickening, especially during summer to late fall in Lake Shoji, suggesting that the lake is in the process of eutrophication.doi: 10.5324/fn.v31i0.1365.Published online: 17 October 2012

  4. [Correlation between ventricular volume calculated manually and by computer].

    Science.gov (United States)

    Gil Moreno, M; Martínez Ríos, M; Grande, F; Cisneros, F; García Moreira, C; Soní, J

    1980-01-01

    We present here a program of ventricular volumes measurements in which an area-lenght procedure and a digital computer were used. The results were compared with those obtained by the manual method using the same formula. The correlative estatistical analysis of these results showed a high index of 0.95 when compared to the telediastolic volumes obtained by both technics, while the index reached 0.99 in reference to the telesistolic volumes and the ejection fraction.

  5. Renormalized Volume

    CERN Document Server

    Gover, A Rod

    2016-01-01

    For any conformally compact manifold with hypersurface boundary we define a canonical renormalized volume functional and compute an explicit, holographic formula for the corresponding anomaly. For the special case of asymptotically Einstein manifolds, our method recovers the known results. The anomaly does not depend on any particular choice of regulator, but the coefficients of divergences do. We give explicit formulae for these divergences valid for any choice of regulating hypersurface; these should be relevant to recent studies of quantum corrections to entanglement entropies. The anomaly is expressed as a conformally invariant integral of a local Q-curvature that generalizes the Branson Q-curvature by including data of the embedding. In each dimension this canonically defines a higher dimensional generalization of the Willmore energy/rigid string action. We show that the variation of these energy functionals is exactly the obstruction to solving a singular Yamabe type problem with boundary data along the...

  6. German register for detection of late sequelae after radiotherapy for children and adolescents (RiSK): present status and first results

    Energy Technology Data Exchange (ETDEWEB)

    Boelling, T.; Schuck, A.; Willich, N. [Dept. of Radiotherapy of the Univ. Hospital Muenster (Germany); Pape, H. [Dept. of Radiotherapy of the Univ. Hospital Duesseldorf (Germany); Ruebe, C. [Dept. of Radiotherapy of the Univ. Saarland, Homburg/Saar (Germany); Meyer, F.M. [Dept. of Radiotherapy of the Clinic of Augsburg (Germany); Martini, C. [Dept. of Radiotherapy of the Univ. Hospitals Freiburg (Germany); Timmermann, B. [Paul Scherrer Inst., Villigen (Switzerland); Asadpour, B. [Dept. of Radiotherapy of the Univ. Hospital Aachen (Germany); Kortmann, R.D. [Dept. of Radiotherapy of the Univ. Hospital Leipzig (Germany); Beck, J.D.; Langer, T.; Paulides, M. [LESS Center, Univ. Children' s Hospital Erlangen (Germany)

    2007-12-15

    Undoubtedly, radiotherapy is an important treatment strategy for many malignancies in paediatric oncology. However, sufficient data about late side effects do not exist. There is a lack of information about radiation dose-effect relationships in view of late side effects in childhood and adolescence. Late effects after radiotherapy in childhood and adolescence have mainly been characterized retrospectively with small patient numbers. Many of these analyses are limited due to little information about organ dose levels and older radiation techniques in some cases. Therefore the German Group of Paediatric Radiation Oncology (APRO) established the 'Register for the evaluation of late side effects after radiation in childhood and adolescence (RiSK)'. Aim of this prospective multicentric register study is to evaluate irradiation dose effect relationships of organs and part of organs with respect to late effects. The feasibility of RiSK has already been shown and first results have recently been published. The characterization of late effects after cancer therapy in childhood is of rising interest. In Germany, several study groups like the 'Late Effects Surveillance System' (LESS) or the working group 'Quality of life' examine different aspects of late effects. In the United States of America, the 'Childhood Cancer Survivor Study' has been established to characterize retrospectively the health status of 5-year-survivors of childhood cancer. In these studies, more than 12,000 patients were evaluated by questionnaires regarding their health status. For radiotherapy, this study is not able to give detailed information about late side effects due to rare data about radiation doses and organ dose levels. To our knowledge, 'RiSK' is the only multicentric study that evaluates radiation associated side effects prospectively with detailed information about organ dose levels. (orig.)

  7. Development of limb volume measuring system

    Science.gov (United States)

    Bhagat, P. K.; Kadaba, P. K.

    1983-01-01

    The mechanisms underlying the reductions in orthostatic tolerance associated with weightlessness are not well established. Contradictory results from measurements of leg volume changes suggest that altered venomotor tone and reduced blood flow may not be the only contributors to orthostatic intolerance. It is felt that a more accurate limb volume system which is insensitive to environmental factors will aid in better quantification of the hemodynamics of the leg. Of the varous limb volume techniques presently available, the ultrasonic limb volume system has proven to be the best choice. The system as described herein is free from environmental effects, safe, simple to operate and causes negligible radio frequency interference problems. The segmental ultrasonic ultrasonic plethysmograph is expected to provide a better measurement of limb volume change since it is based on cross-sectional area measurements.

  8. Composed Scattering Model for Direct Volume Rendering

    Institute of Scientific and Technical Information of China (English)

    蔡文立; 石教英

    1996-01-01

    Based on the equation of transfer in transport theory of optical physics,a new volume rendering model,called composed scattering model(CSM),is presented.In calculating the scattering term of the equation,it is decomposed into volume scattering intensity and surface scattering intensity,and they are composed with the boundary detection operator as the weight function.This proposed model differs from the most current volume rendering models in the aspect that in CSM segmentation and illumination intensity calculation are taken as two coherent parts while in existing models they are regarded as two separate ones.This model has been applied to the direct volume rendering of 3D data sets obtained by CT and MRI.The resultant images show not only rich details but also clear boundary surfaces.CSM is demonstrated to be an accurate volume rendering model suitable for CT and MRI data sets.

  9. Integers annual volume 2013

    CERN Document Server

    Landman, Bruce

    2014-01-01

    ""Integers"" is a refereed online journal devoted to research in the area of combinatorial number theory. It publishes original research articles in combinatorics and number theory. This work presents all papers of the 2013 volume in book form.

  10. Long-Term Effects of Resistance Exercise Training on Cognition and Brain Volume in Older Women: Results from a Randomized Controlled Trial.

    Science.gov (United States)

    Best, John R; Chiu, Bryan K; Liang Hsu, Chun; Nagamatsu, Lindsay S; Liu-Ambrose, Teresa

    2015-11-01

    Aerobic exercise training has been shown to attenuate cognitive decline and reduce brain atrophy with advancing age. The extent to which resistance exercise training improves cognition and prevents brain atrophy is less known, and few studies include long-term follow-up cognitive and neuroimaging assessments. We report data from a randomized controlled trial of 155 older women, who engaged in 52 weeks of resistance training (either once- or twice-weekly) or balance-and-toning (twice-weekly). Executive functioning and memory were assessed at baseline, 1-year follow-up (i.e., immediately post-intervention), and 2-year follow-up. A subset underwent structural magnetic resonance imaging scans at those time points. At 2-year follow-up, both frequencies of resistance training promoted executive function compared to balance-and-toning (standardized difference [d]=.31-.48). Additionally, twice-weekly resistance training promoted memory (d=.45), reduced cortical white matter atrophy (d=.45), and increased peak muscle power (d=.27) at 2-year follow-up relative to balance-and-toning. These effects were independent of one another. These findings suggest resistance training may have a long-term impact on cognition and white matter volume in older women.

  11. Whole-organ perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma: acquisition technique, post-processing and initial results

    Energy Technology Data Exchange (ETDEWEB)

    Kandel, Sonja; Kloeters, Christian; Meyer, Henning; Hein, Patrick; Rogalla, Patrik [Charite - Universitaetsmedizin Berlin, Department of Radiology, Campus Charite Mitte, Berlin (Germany); Hilbig, Andreas [Charite - University Medicine, Medical Clinic III - Hematology and Oncology, Campus Virchow Klinikum, Berlin (Germany)

    2009-11-15

    The purpose of this study was to evaluate a whole-organ perfusion protocol of the pancreas in patients with primary pancreas carcinoma and to analyse perfusion differences between normal and diseased pancreatic tissue. Thirty patients with primary pancreatic malignancy were imaged on a 320-slice CT unit. Twenty-nine cancers were histologically proven. CT data acquisition was started manually after contrast-material injection (8 ml/s, 350 mg iodine/ml) and dynamic density measurements in the right ventricle. After image registration, perfusion was determined with the gradient-relationship technique and volume regions-of-interest were defined for perfusion measurements. Contrast time-density curves and perfusion maps were generated. Statistical analysis was performed using the Kolmogorov-Smirnov test for analysis of normal distribution and Kruskal-Wallis test (nonparametric ANOVA) with Bonferroni correction for multiple stacked comparisons. In all 30 patients the entire pancreas was imaged, and registration could be completed in all cases. Perfusion of pancreatic carcinomas was significantly lower than of normal pancreatic tissue (P < 0.001) and could be visualized on colored perfusion maps. The 320-slice CT allows complete dynamic visualization of the pancreas and enables calculation of whole-organ perfusion maps. Perfusion imaging carries the potential to improve detection of pancreatic cancers due to the perfusion differences. (orig.)

  12. Generalized Partial Volume

    DEFF Research Database (Denmark)

    Darkner, Sune; Sporring, Jon

    2011-01-01

    Mutual Information (MI) and normalized mutual information (NMI) are popular choices as similarity measure for multimodal image registration. Presently, one of two approaches is often used for estimating these measures: The Parzen Window (PW) and the Generalized Partial Volume (GPV). Their theoret......Mutual Information (MI) and normalized mutual information (NMI) are popular choices as similarity measure for multimodal image registration. Presently, one of two approaches is often used for estimating these measures: The Parzen Window (PW) and the Generalized Partial Volume (GPV...

  13. Swept Volume Parameterization for Isogeometric Analysis

    Science.gov (United States)

    Aigner, M.; Heinrich, C.; Jüttler, B.; Pilgerstorfer, E.; Simeon, B.; Vuong, A.-V.

    Isogeometric Analysis uses NURBS representations of the domain for performing numerical simulations. The first part of this paper presents a variational framework for generating NURBS parameterizations of swept volumes. The class of these volumes covers a number of interesting free-form shapes, such as blades of turbines and propellers, ship hulls or wings of airplanes. The second part of the paper reports the results of isogeometric analysis which were obtained with the help of the generated NURBS volume parameterizations. In particular we discuss the influence of the chosen parameterization and the incorporation of boundary conditions.

  14. Present time

    CERN Document Server

    Romero, Gustavo E

    2014-01-01

    The idea of a moving present or `now' seems to form part of our most basic beliefs about reality. Such a present, however, is not reflected in any of our theories of the physical world. I show in this article that presentism, the doctrine that only what is present exists, is in conflict with modern relativistic cosmology and recent advances in neurosciences. I argue for a tenseless view of time, where what we call `the present' is just an emergent secondary quality arising from the interaction of perceiving self-conscious individuals with their environment. I maintain that there is no flow of time, but just an ordered system of events.

  15. Sexual Assault and Sexual Harassment in the U.S. Military: Annex to Volume 3. Tabular Results from the 2014 RAND Military Workplace Study for Coast Guard Service Members

    Science.gov (United States)

    2015-01-01

    punished or treated unfairly in the workplace if you did not do something sexual? (Follow-up questions established that target had direct evidence of an...from work made you feel like you would get punished or treated unfairly in the workplace if you did not do something sexual? (Follow-up questions...SEXUAL ASSAULT AND SEXUAL HARASSMENT IN THE U.S. MILITARY Annex to Volume 3. Tabular Results from the 2014 RAND Military Workplace Study for

  16. Analytical Results for 35 Mine-Waste Tailings Cores and Six Bed-Sediment Samples, and An Estimate of the Volume of Contaminated Material at Buckeye Meadow on Upper Basin Creek, Northern Jefferson County, Montana

    Science.gov (United States)

    Fey, David L.; Church, Stan E.; Finney, Christopher J.

    1999-01-01

    Metal-mining related wastes in the Boulder River basin study area in northern Jefferson County, Montana have been implicated in their detrimental effects on water quality with regard to acid-generation and toxic-metal solubilization. Flotation-mill tailings in the meadow below the Buckeye mine, hereafter referred to as the Buckeye mill-tailings site, have been identified as significant contributors to water quality degradation of Basin Creek, Montana. Basin Creek is one of three tributaries to the Boulder River in the study area; bed sediments and waters draining from the Buckeye mine have also been implicated. Geochemical analysis of 35 tailings cores and six bed-sediment samples was undertaken to determine the concentrations of Ag, As, Cd, Cu, Pb,and Zn present in these materials. These elements are environmentally significant, in that they can be toxic to fish and/or the invertebrate organisms that constitute their food. A suite of one-inch cores of dispersed flotation-mill tailings and underlying premining material was taken from a large, flat area north of Basin Creek near the site of the Buckeye mine. Thirty-five core samples were taken and divided into 204 subsamples. The samples were analyzed by ICP-AES (inductively coupled plasma-atomic emission spectroscopy) using a mixed-acid digestion. Results of the core analyses show that the elements listed above are present at moderate to very high concentrations (arsenic to 63,000 ppm, silver to 290 ppm, cadmium to 370 ppm, copper to 4,800 ppm, lead to 93,000 ppm, and zinc to 23,000 ppm). Volume calculations indicate that an estimated 8,400 metric tons of contaminated material are present at the site. Six bed-sediment samples were also subjected to the mixed-acid total digestion, and a warm (50°C) 2M HCl-1% H2O2 leach and analyzed by ICP-AES. Results indicate that bed sediments of Basin Creek are only slightly impacted by past mining above the Buckeye-Enterprise complex, moderately impacted at the upper (eastern

  17. NPR hazards review: (Phase 1, Production only appendixes). Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Miller, N.R.; Trumble, R.E.

    1962-08-15

    The NPR Hazards Review is being issued in a series of volumes. Volume 1, which has already been published, was of the nature of an expanded summary. It included the results of hazards analyses with some explanatory material to put the results in context. Volume 2 presents results of reviews made after the preparation of Volume 1. It also contains supporting material and details not included in Volume 1. Volumes 1 and 2 together provide a nearly complete ``Design Hazards Review of the NPR.`` However, certain remaining problems still exist and are to be the subject of a continuing R&D program. These problems and programs are discussed in Appendix H. Neither Volume 1 nor Volume 2 treat operational aspects of reactor hazards in detail. This area of concern will be the primary subject of a third volume of the NPR Hazards Review. This third volume, to be prepared and issued at a later date, may also contain information supplementing Volumes 1 and 2.

  18. Effects of smoking on cerebral and ventricular volumes in healthy males

    Institute of Scientific and Technical Information of China (English)

    Hyun-Jun Kim; Jae-Hoon Jun; Gye-Rae Tack; Soon-Cheol Chung; Mi-Hyun Choi; Beob-Yi Lee; Su-Jeong Lee; Jae-Woong Yang; Ji-Hye Kim; Jin-Seung Choi; Dong-Won Kang; Jang-Yeon Park

    2011-01-01

    Previous studies have reported decreased cerebral volume as a result of smoking.However,little is known about accompanying changes in ventricular volume for healthy subjects who smoke,although ventricular volume is increased in patients with multiple sclerosis who smoke.The present study analyzed whether cerebral volume decreased with smoking through the use of magnetic resonance imaging.In addition,accompanying changes in ventricular volume that resulted from decreased cerebral volume and smoking were analyzed in healthy subjects.When multivariate lysis of covariance was performed by integrating the 2 age groups,aged 20-28 years and 40-49 years,with statistical significance,results showed that cerebral volume of smokers was smaller and ventricular volume was greater compared with the non-smokers.These findings suggest that ventricular volume changes could be utilized to characterize the effects of smoking.

  19. TU-CD-304-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Trajectory Modulated Arc Therapy: Development of Novel Arc Delivery Techniques Integrating Dynamic Table Motion for Extended Volume Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Chin, E; Hoppe, R; Million, L; Loo, B; Koong, A; Xing, L; Hsu, A; Fahimian, B [Stanford University, Stanford, CA (United States); Otto, K [University of British Columbia, Vancouver, BC (Canada)

    2015-06-15

    Purpose: Integration of coordinated robotic table motion with inversely-planned arc delivery has the potential to resolve table-top delivery limitations of large-field treatments such as Total Body Irradiation (TBI), Total Lymphoid Irradiation (TLI), and Cranial-Spinal Irradiation (CSI). We formulate the foundation for Trajectory Modulated Arc Therapy (TMAT), and using Varian Developer Mode capabilities, experimentally investigate its practical implementation for such techniques. Methods: A MATLAB algorithm was developed for inverse planning optimization of the table motion, MLC positions, and gantry motion under extended-SSD geometry. To maximize the effective field size, delivery trajectories for TMAT TBI were formed with the table rotated at 270° IEC and dropped vertically to 152.5cm SSD. Preliminary testing of algorithm parameters was done through retrospective planning analysis. Robotic delivery was programmed using custom XML scripting on the TrueBeam Developer Mode platform. Final dose was calculated using the Eclipse AAA algorithm. Initial verification of delivery accuracy was measured using OSLDs on a solid water phantom of varying thickness. Results: A comparison of DVH curves demonstrated that dynamic couch motion irradiation was sufficiently approximated by static control points spaced in intervals of less than 2cm. Optimized MLC motion decreased the average lung dose to 68.5% of the prescription dose. The programmed irradiation integrating coordinated table motion was deliverable on a TrueBeam STx linac in 6.7 min. With the couch translating under an open 10cmx20cm field angled at 10°, OSLD measurements along the midline of a solid water phantom at depths of 3, 5, and 9cm were within 3% of the TPS AAA algorithm with an average deviation of 1.2%. Conclusion: A treatment planning and delivery system for Trajectory Modulated Arc Therapy of extended volumes has been established and experimentally demonstrated for TBI. Extension to other treatment

  20. CATCHY PRESENTATIONS

    DEFF Research Database (Denmark)

    Eriksen, Kaare; Tollestrup, Christian; Ovesen, Nis

    2011-01-01

    An important competence for designers is the ability to communicate and present ideas and proposals for customers, partners, investors and colleagues. The Pecha Kucha principle, developed by Astrid Klein and Mark Dytham, has become a widely used and easy format for the presentation of new concepts...

  1. Predição de peso ao nascimento pela ultra-sonografia tridimensional usando o volume do braço fetal: resultados preliminares Prediction of birth weight by three-dimensional ultrasonography using fetal upper arm volume: preliminary results

    Directory of Open Access Journals (Sweden)

    Márcio Fragoso Vieira

    2008-04-01

    compared with Shepard's and Hadlock's formulas. RESULTS: fetal upper arm volume was strongly correlated to birth weight (r=0.83; p0.05. Birth weight predicted by fetal upper arm volume had a mean error lower than Hadlock's formula, but this difference was not statistically significant (p>0.05. CONCLUSIONS: the accuracy of fetal upper arm volume obtained through 3DUS is similar to the accuracy of bidimensional ultrasound in the prediction of birth weight. These findings need to be confirmed by larger studies.

  2. Information Presentation

    Science.gov (United States)

    Holden, Kritina L.; Thompson, Shelby G.; Sandor, Aniko; McCann, Robert S.; Kaiser, Mary K.; Adelstein, Barnard D.; Begault, Durand R.; Beutter, Brent R.; Stone, Leland S.; Godfroy, Martine

    2009-01-01

    The goal of the Information Presentation Directed Research Project (DRP) is to address design questions related to the presentation of information to the crew. In addition to addressing display design issues associated with information formatting, style, layout, and interaction, the Information Presentation DRP is also working toward understanding the effects of extreme environments encountered in space travel on information processing. Work is also in progress to refine human factors-based design tools, such as human performance modeling, that will supplement traditional design techniques and help ensure that optimal information design is accomplished in the most cost-efficient manner. The major areas of work, or subtasks, within the Information Presentation DRP for FY10 are: 1) Displays, 2) Controls, 3) Procedures and Fault Management, and 4) Human Performance Modeling. The poster will highlight completed and planned work for each subtask.

  3. Information Presentation

    Science.gov (United States)

    Holden, K.L.; Boyer, J.L.; Sandor, A.; Thompson, S.G.; McCann, R.S.; Begault, D.R.; Adelstein, B.D.; Beutter, B.R.; Stone, L.S.

    2009-01-01

    The goal of the Information Presentation Directed Research Project (DRP) is to address design questions related to the presentation of information to the crew. The major areas of work, or subtasks, within this DRP are: 1) Displays, 2) Controls, 3) Electronic Procedures and Fault Management, and 4) Human Performance Modeling. This DRP is a collaborative effort between researchers at Johnson Space Center and Ames Research Center.

  4. Monitoring and control requirement definition study for dispersed storage and generation (DSG). Volume IV. Final report, Appendix C: identification from utility visits of present and future approaches to integration of DSG into distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    1980-10-01

    A major aim of the US National Energy Policy, as well as that of the New York State Energy Research and Development Authority, is to conserve energy and to shift from oil to more abundant domestic fuels and renewable energy sources. Dispersed Storage and Generation (DSG) is the term that characterizes the present and future dispersed, relatively small (<30 MW) energy systems, such as solar thermal electric, photovoltaic, wind, fuel cell, storage battery, hydro, and cogeneration, which can help achieve these national energy goals and can be dispersed throughout the distribution portion of an electric utility system. As a result of visits to four utilities concerned with the use of DSG power sources on their distribution networks, some useful impressions of present and future approaches to the integration of DSGs into electrical distribution network have been obtained. A more extensive communications and control network will be developed by utilities for control of such sources for future use. Different approaches to future utility systems with DSG are beginning to take shape. The new DSG sources will be in decentralized locations with some measure of centralized control. The utilities have yet to establish firmly the communication and control means or their organization. For the present, the means for integrating the DSGs and their associated monitoring and control equipment into a unified system have not been decided.

  5. Initial performance assessment of the disposal of spent nuclear fuel and high-level waste stored at Idaho National Engineering Laboratory. Volume 1, Methodology and results

    Energy Technology Data Exchange (ETDEWEB)

    Rechard, R.P. [ed.

    1993-12-01

    This performance assessment characterized plausible treatment options conceived by the Idaho National Engineering Laboratory (INEL) for its spent fuel and high-level radioactive waste and then modeled the performance of the resulting waste forms in two hypothetical, deep, geologic repositories: one in bedded salt and the other in granite. The results of the performance assessment are intended to help guide INEL in its study of how to prepare wastes and spent fuel for eventual permanent disposal. This assessment was part of the Waste Management Technology Development Program designed to help the US Department of Energy develop and demonstrate the capability to dispose of its nuclear waste. Although numerous caveats must be placed on the results, the general findings were as follows: Though the waste form behavior depended upon the repository type, all current and proposed waste forms provided acceptable behavior in the salt and granite repositories.

  6. LANDSAT-4 Science Characterization Early Results. Volume 4: Applications. [agriculture, soils land use, geology, hydrology, wetlands, water quality, biomass identification, and snow mapping

    Science.gov (United States)

    Barker, J. L. (Editor)

    1985-01-01

    The excellent quality of TM data allows researchers to proceed directly with applications analyses, without spending a significant amount of time applying various corrections to the data. The early results derived of TM data are discussed for the following applications: agriculture, land cover/land use, soils, geology, hydrology, wetlands biomass, water quality, and snow.

  7. Glomerular hyperfiltration in type 1 diabetes mellitus results from primary changes in proximal tubular sodium handling without changes in volume expansion.

    NARCIS (Netherlands)

    Vervoort, G.M.M.; Veldman, B.A.J.; Berden, J.H.M.; Smits, P.; Wetzels, J.F.M.

    2005-01-01

    BACKGROUND: Glomerular hyperfiltration plays a role in the pathophysiology of diabetic nephropathy. An increase in the glomerular filtration rate (GFR) could result from primary actions at the glomerular/vascular level or could be the consequence of a primary increase in proximal tubular sodium

  8. Colloid volume loading does not mitigate decreases in central blood volume during simulated hemorrhage while heat stressed

    DEFF Research Database (Denmark)

    Crandall, Craig G; Wilson, Thad E; Marving, Jens

    2012-01-01

    Heat stress results in profound reductions in the capacity to withstand a simulated hemorrhagic challenge; however, this capacity is normalized if the individual is volume loaded prior to the challenge. The present study tested the hypothesis that volume loading during passive heat stress attenua...

  9. Systems interaction results from the digraph matrix analysis of the Watts Bar Nuclear Power Plant high pressure safety injection systems. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Sacks, I.J.; Ashmore, B.C.; Alesso, H.P.

    1983-07-01

    Spatial and functional coupling (including human actions) of nuclear power plant systems that lead to interdependencies are called Systems Interactions. At present, the US Nuclear Regulatory Commission (NRC) is investigating ways of integrating a systems interactions study with existing Probabilistic Risk Assessment efforts. One approach is based on graph-theoretic methods utilizing matrix representations of logic diagrams called Digraph Matrix Analysis (DMA). The objective in this report is to demonstrate the capabilities of Digraph Matrix Analysis to model an accident sequence (including front-line systems, support systems and human actions) as a continuous, well-integrated logic model in order to identify and evaluate functional systems interactions. The selected accident sequence, loss of high pressure safety injection during a LOCA, was modeled and qualitative and quantitative comparisons were made to the Reactor Safety Study (WASH 1400) and other studies.

  10. Systems interaction results from the digraph matrix analysis of the Watts Bar Nuclear Power Plant high pressure safety injection systems. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Sacks, I.J.; Ashmore, B.C.; Alesso, H.P.

    1983-07-01

    Spatial and functional coupling of nuclear power plant systems that lead to interdependencies are called Systems Interactions. At present, the US Nuclear Regulatory Commission (NRC) is investigating ways of integrating a systems interactions study with existing Probabilistic Risk Assessment efforts. One approach is based on graph-theoretic methods utilizing matrix representations of logic diagrams called Digraph Matrix Analysis (DMA). The objective in this report is to demonstrate the capabilities of Digraph Matrix Analysis to model an accident sequence (including front line systems, support systems and human actions) as a continuous, well-integrated logic model in order to identify and evaluate functional systems interactions. The selected accident sequence, loss of high pressure safety injection during an S1 LOCA, was modeled and qualitative and quantitative comparisons were made to WASH 1400 aand other studies.

  11. Computer-assisted venous thrombosis volume quantification.

    Science.gov (United States)

    Puentes, John; Dhibi, Mounir; Bressollette, Luc; Guias, Bruno; Solaiman, Basel

    2009-03-01

    Venous thrombosis (VT) volume assessment, by verifying its risk of progression when anticoagulant or thrombolytic therapies are prescribed, is often necessary to screen life-threatening complications. Commonly, VT volume estimation is done by manual delineation of few contours in the ultrasound (US) image sequence, assuming that the VT has a regular shape and constant radius, thus producing significant errors. This paper presents and evaluates a comprehensive functional approach based on the combination of robust anisotropic diffusion and deformable contours to calculate VT volume in a more accurate manner when applied to freehand 2-D US image sequences. Robust anisotropic filtering reduces image speckle noise without generating incoherent edge discontinuities. Prior knowledge of the VT shape allows initializing the deformable contour, which is then guided by the noise-filtering outcome. Segmented contours are subsequently used to calculate VT volume. The proposed approach is integrated into a system prototype compatible with existing clinical US machines that additionally tracks the acquired images 3-D position and provides a dense Delaunay triangulation required for volume calculation. A predefined robust anisotropic diffusion and deformable contour parameter set enhances the system usability. Experimental results pertinence is assessed by comparison with manual and tetrahedron-based volume computations, using images acquired by two medical experts of eight plastic phantoms and eight in vitro VTs, whose independently measured volume is the reference ground truth. Results show a mean difference between 16 and 35 mm(3) for volumes that vary from 655 to 2826 mm(3). Two in vivo VT volumes are also calculated to illustrate how this approach could be applied in clinical conditions when the real value is unknown. Comparative results for the two experts differ from 1.2% to 10.08% of the smallest estimated value when the image acquisition cadences are similar.

  12. Investigation of difficult component effects on finite element model vibration prediction for the Bell AG-1G helicopter. Volume 2: Correlation results

    Science.gov (United States)

    Dompka, R. V.

    1989-01-01

    Under the NASA-sponsored DAMVIBS (Design Analysis Methods for VIBrationS) program, a series of ground vibration tests and NASTRAN finite element model (FEM) correlations were conducted on the Bell AH-1G helicopter gunship to investigate the effects of difficult components on the vibration response of the airframe. Previous correlations of the AG-1G showed good agreement between NASTRAN and tests through 15 to 20 Hz, but poor agreement in the higher frequency range of 20 to 30 Hz. Thus, this effort emphasized the higher frequency airframe vibration response correlations and identified areas that need further R and T work. To conduct the investigations, selected difficult components (main rotor pylon, secondary structure, nonstructural doors/panels, landing gear, engine, furl, etc.) were systematically removed to quantify their effects on overall vibratory response of the airframe. The entire effort was planned and documented, and the results reviewed by NASA and industry experts in order to ensure scientific control of the testing, analysis, and correlation exercise. In particular, secondary structure and damping had significant effects on the frequency response of the airframe above 15 Hz. Also, the nonlinear effects of thrust stiffening and elastomer mounts were significant on the low frequency pylon modes below main rotor 1p (5.4 Hz). The results of the NASTRAN FEM correlations are given.

  13. High-solids black liquor firing in pulp and paper industry kraft recovery boilers: Phase 1 -- Final report. Volume 2: Project technical results

    Energy Technology Data Exchange (ETDEWEB)

    Southards, W.T.; Clement, J.L.; McIlroy, R.A.; Tharp, M.R.; Verrill, C.L.; Wessell, R.A.

    1995-11-01

    This project is a multiple-phase effort to develop technologies to improve high-solids black liquor firing in pulp mill recovery boilers. The principal means to this end is to construct and operate a pilot-scale recovery furnace simulator (RFS) in which these technologies can be tested. The Phase 1 objectives are to prepare a preliminary design for the RFS, delineate a project concept for evaluating candidate technologies, establish industrial partners, and report the results. Phase 1 addressed the objectives with seven tasks: Develop a preliminary design of the RFS; estimate the detailed design and construction costs of the RFS and the balance of the project; identify interested parties in the paper industry and key suppliers; plan the Phase 2 and Phase 3 tests to characterize the RFS; evaluate the economic justification for high-solids firing deployment in the industry; evaluate high-solids black liquor property data to support the RFS design; manage the project and reporting results, which included planning the future program direction.

  14. Technical presentation

    CERN Multimedia

    FI Department

    2008-01-01

    RADIOSPARES, the leading catalogue distributor of components (electronic, electrical, automation, etc.) and industrial supplies will be at CERN on Friday 3 October 2008 (Main Building, Room B, from 9.00 a.m. to 3.00 p.m.) to introduce its new 2008/2009 catalogue. This will be the opportunity for us to present our complete range of products in more detail: 400 000 part numbers available on our web site (Radiospares France, RS International, extended range of components from other manufacturers); our new services: quotations, search for products not included in the catalogue, SBP products (Small Batch Production: packaging in quantities adapted to customers’ requirements); partnership with our focus manufacturers; demonstration of the on-line purchasing tool implemented on our web site in conjunction with CERN. RADIOSPARES will be accompanied by representatives of FLUKE and TYCO ELECTRONICS, who will make presentations, demonstrate materials and answer any technical questio...

  15. Overview Presentation

    Science.gov (United States)

    Lytle, John

    2001-01-01

    This report provides an overview presentation of the 2000 NPSS (Numerical Propulsion System Simulation) Review and Planning Meeting. Topics include: 1) a background of the program; 2) 1999 Industry Feedback; 3) FY00 Status, including resource distribution and major accomplishments; 4) FY01 Major Milestones; and 5) Future direction for the program. Specifically, simulation environment/production software and NPSS CORBA Security Development are discussed.

  16. Assessment of effectiveness of geologic isolation systems. Geologic-simulation model for a hypothetical site in the Columbia Plateau. Volume 2: results

    Energy Technology Data Exchange (ETDEWEB)

    Foley, M.G.; Petrie, G.M.; Baldwin, A.J.; Craig, R.G.

    1982-06-01

    This report contains the input data and computer results for the Geologic Simulation Model. This model is described in detail in the following report: Petrie, G.M., et. al. 1981. Geologic Simulation Model for a Hypothetical Site in the Columbia Plateau, Pacific Northwest Laboratory, Richland, Washington. The Geologic Simulation Model is a quasi-deterministic process-response model which simulates, for a million years into the future, the development of the geologic and hydrologic systems of the ground-water basin containing the Pasco Basin. Effects of natural processes on the ground-water hydrologic system are modeled principally by rate equations. The combined effects and synergistic interactions of different processes are approximated by linear superposition of their effects during discrete time intervals in a stepwise-integration approach.

  17. Influence of prior activity on residual limb volume and shape measured using plaster casting: Results from individuals with transtibial limb loss

    Directory of Open Access Journals (Sweden)

    Joan E. Sanders, PhD

    2013-10-01

    Full Text Available The purpose of this research was to determine whether prior activity affected the shape of a plaster cast taken of a transtibial residual limb. Plaster casts were taken twice on one day in 24 participants with transtibial limb loss, with 5 s between doffing and casting in one trial (PDI-5s and 20 min in the other trial (PDI-20m. The ordering of the trials was randomized. The mean +/- standard deviation radial difference between PDI-20m and PDI-5s was 0.34 +/- 0.21 mm when PDI-5s was conducted first and -0.02 +/- 0.20 mm when PDI-20m was conducted first. Ordering of the trials had a statistically significant influence on the mean radial difference between the two shapes (p = 0.008. The result shows that prior activity influenced the residual limb cast shape. Practitioners should be mindful of prior activity and doffing history when casting an individual's limb for socket design and prosthetic fitting.

  18. Performance assessment of the direct disposal in unsaturated tuff or spent nuclear fuel and high-level waste owned by USDOE: Volume 2, Methodology and results

    Energy Technology Data Exchange (ETDEWEB)

    Rechard, R.P. [ed.

    1995-03-01

    This assessment studied the performance of high-level radioactive waste and spent nuclear fuel in a hypothetical repository in unsaturated tuff. The results of this 10-month study are intended to help guide the Office of Environment Management of the US Department of Energy (DOE) on how to prepare its wastes for eventual permanent disposal. The waste forms comprised spent fuel and high-level waste currently stored at the Idaho National Engineering Laboratory (INEL) and the Hanford reservations. About 700 metric tons heavy metal (MTHM) of the waste under study is stored at INEL, including graphite spent nuclear fuel, highly enriched uranium spent fuel, low enriched uranium spent fuel, and calcined high-level waste. About 2100 MTHM of weapons production fuel, currently stored on the Hanford reservation, was also included. The behavior of the waste was analyzed by waste form and also as a group of waste forms in the hypothetical tuff repository. When the waste forms were studied together, the repository was assumed also to contain about 9200 MTHM high-level waste in borosilicate glass from three DOE sites. The addition of the borosilicate glass, which has already been proposed as a final waste form, brought the total to about 12,000 MTHM.

  19. SCENARIOS FOR MEETING CALIFORNIA'S 2050 CLIMATE GOALS California's Carbon Challenge Phase II Volume I: Non-Electricity Sectors and Overall Scenario Results

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Max; Greenblatt, Jeffrey; Donovan, Sally; Nelson, James; Mileva, Ana; Johnston, Josiah; Kammen, Daniel

    2014-06-01

    This study provides an updated analysis of long-term energy system scenarios for California consistent with the State meeting its 2050 climate goal, including detailed analysis and assessment of electricity system build-out, operation, and costs across the Western Electricity Coordinating Council (WECC) region. Four key elements are found to be critical for the State to achieve its 2050 goal of 80 percent greenhouse (GHG) reductions from the 1990 level: aggressive energy efficiency; clean electricity; widespread electrification of passenger vehicles, building heating, and industry heating; and large-scale production of low-carbon footprint biofuels to largely replace petroleum-based liquid fuels. The approach taken here is that technically achievable energy efficiency measures are assumed to be achieved by 2050 and aggregated with the other key elements mentioned above to estimate resultant emissions in 2050. The energy and non-energy sectors are each assumed to have the objective of meeting an 80 percent reduction from their respective 1990 GHG levels for the purposes of analysis. A different partitioning of energy and non-energy sector GHG greenhouse reductions is allowed if emission reductions in one sector are more economic or technically achievable than in the other. Similarly, within the energy or non-energy sectors, greater or less than 80 percent reduction from 1990 is allowed for sub-sectors within the energy or non-energy sectors as long as the overall target is achieved. Overall emissions for the key economy-wide scenarios are considered in this report. All scenarios are compliant or nearly compliant with the 2050 goal. This finding suggests that multiple technical pathways exist to achieve the target with aggressive policy support and continued technology development of largely existing technologies.

  20. Volume of intersection of two cones

    CERN Document Server

    Balogun, F A; Cesareo, R

    2000-01-01

    Radiation measurements utilising collimated source and detector systems invariably result in a target volume described by the overlap of their fields of view. When these collimators are cylindrical, this is derived from the volume of intersection of two cones. In general, analysis of this volume does not lend itself to a direct analytical process. Here, numerical methods of estimating the common volume of two intersecting right cones are presented. These include methods which employ, (a) a sequential scanning of an elemental volume with a predetermined size across a defined space containing the volume of interest and (b) a Monte Carlo technique. The accuracy obtainable and the execution time in the first type of algorithm depend on the size of the elemental volume (bin-size). On the other hand, these two parameters are independent of the bin-size but dependent on the number of histories sampled, for the Monte Carlo technique. At 0 deg. angle of inclination, where an analytical estimation is easily obtained, t...

  1. Using Task Data in Diagnostic Radiology. Research Report No. 8. Volume 2. Curriculum Objectives for Radiologic Technology.

    Science.gov (United States)

    Gilpatrick, Eleanor; Gullion, Christina

    This volume is the result of the application of the Health Services Mobility Study (HSMS) curriculum design method in radiologic technology and is presented in conjunction with volume 1, which reports the task analysis results. Volume 2 contains job-related behavioral curriculum objectives for the aide, technician, and technologist levels in…

  2. Safety and efficacy of vertebroplasty: Early results of a prospective one-year case series of osteoporosis patients in an academic high-volume center

    Directory of Open Access Journals (Sweden)

    Diel Peter

    2009-01-01

    Full Text Available Background: Vertebroplasty (VP is a cost-efficient alternative to kyphoplasty. However, it is considered inferior when it comes to maintaining safety and in vertebral body (VB height restoration. We assess the safety and efficacy of VP in alleviating pain, improving quality of life (QoL, and restoring alignment. Materials and Methods: In a prospective monocenter case series, from April 2007 until July 2008, 1,422 vertebroplasties were performed, during 307 interventions, in 279 patients with traumatic, lytic, and osteoporotic fractures with 28 repeat interventions, for new fractures after the primary surgery, in 28 patients. The 226 interventions (n=203 patients done for osteoporotic fractures were analyzed for demographics, treatment and radiographic details, pain alleviation, QoL improvement [NASS and Euroqol (EQ-5D] and complications. Results: Osteoporotic patient sample consisted of 77.8% (n=158 females with a median age of 78 years and 45 males who had the same median age. Around 69% of these patients were ASA (American Society of Anesthesiologists grade 3 and above. On an average there were 1.8 VBs fractured and five VBs treated,whereas the most frequently performed cementations were in six (35.6%, n=80 or five (19.6%, n=44 levels. About 36.5%, (n=414 of the interventions were localized at the thoraco-lumbar junction (Th12-L2. On applying the Genant classification, there was a slight height reduction in 13.1% (n=29, a medium loss in 34.3% (n=78, and a severe loss of height in 52.6% (n=119. The pre-operative pain was assessed by the visual analog scale (VAS and decreased from 56.7 to 41.4 pts after two months. Accordingly, the QoL on the EQ-5D measure (0.6 to 1 improved from 0.32 pts before surgery to 0.58 pts after two months. The pre-operative Beck index (anterior height/posterior height improved from a mean of 0.66 preoperative to 0.80 post-operative and remained stable at two months post-operatively. There were cement leakages in 33% of

  3. Measurable inhomogeneities in stock trading volume flow

    Science.gov (United States)

    Cortines, A. A. G.; Riera, R.; Anteneodo, C.

    2008-08-01

    We investigate the statistics of volumes of shares traded in stock markets. We show that the stochastic process of trading volumes can be understood on the basis of a mixed Poisson process at the microscopic time level. The beta distribution of the second kind (also known as q-gamma distribution), that has been proposed to describe empirical volume histograms, naturally results from our analysis. In particular, the shape of the distribution at small volumes is governed by the degree of granularity in the trading process, while the exponent controlling the tail is a measure of the inhomogeneities in market activity. Furthermore, the present case furnishes empirical evidence of how power law probability distributions can arise as a consequence of a fluctuating intrinsic parameter.

  4. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    regression model. Analysis of variance was used to determine whether the absolute log proportional error differed by the intended injection volume. Interindividual and intraindividual deviation from the intended injection volume was also characterized. As the intended injection volumes decreased, the absolute log proportional injection volume error increased (analysis of variance, P injection volumes between physicians and pediatric PACU nurses; however, the difference in absolute bias was significantly higher for nurses with a 2-sided significance of P = .03. Clinically significant dose variation occurs when injecting volumes ≤0.5 mL. Administering small volumes of medications may result in unintended medication administration errors.

  5. Renormalized Volumes with Boundary

    CERN Document Server

    Gover, A Rod

    2016-01-01

    We develop a general regulated volume expansion for the volume of a manifold with boundary whose measure is suitably singular along a separating hypersurface. The expansion is shown to have a regulator independent anomaly term and a renormalized volume term given by the primitive of an associated anomaly operator. These results apply to a wide range of structures. We detail applications in the setting of measures derived from a conformally singular metric. In particular, we show that the anomaly generates invariant (Q-curvature, transgression)-type pairs for hypersurfaces with boundary. For the special case of anomalies coming from the volume enclosed by a minimal hypersurface ending on the boundary of a Poincare--Einstein structure, this result recovers Branson's Q-curvature and corresponding transgression. When the singular metric solves a boundary version of the constant scalar curvature Yamabe problem, the anomaly gives generalized Willmore energy functionals for hypersurfaces with boundary. Our approach ...

  6. Technical presentation

    CERN Multimedia

    FP Department

    2009-01-01

    07 April 2009 Technical presentation by Leuze Electronics: 14.00 – 15.00, Main Building, Room 61-1-017 (Room A) Photoelectric sensors, data identification and transmission systems, image processing systems. We at Leuze Electronics are "the sensor people": we have been specialising in optoelectronic sensors and safety technology for accident prevention for over 40 years. Our dedicated staff are all highly customer oriented. Customers of Leuze Electronics can always rely on one thing – on us! •\tFounded in 1963 •\t740 employees •\t115 MEUR turnover •\t20 subsidiaries •\t3 production facilities in southern Germany Product groups: •\tPhotoelectric sensors •\tIdentification and measurements •\tSafety devices

  7. Reachable volume RRT

    KAUST Repository

    McMahon, Troy

    2015-05-01

    © 2015 IEEE. Reachable volumes are a new technique that allows one to efficiently restrict sampling to feasible/reachable regions of the planning space even for high degree of freedom and highly constrained problems. However, they have so far only been applied to graph-based sampling-based planners. In this paper we develop the methodology to apply reachable volumes to tree-based planners such as Rapidly-Exploring Random Trees (RRTs). In particular, we propose a reachable volume RRT called RVRRT that can solve high degree of freedom problems and problems with constraints. To do so, we develop a reachable volume stepping function, a reachable volume expand function, and a distance metric based on these operations. We also present a reachable volume local planner to ensure that local paths satisfy constraints for methods such as PRMs. We show experimentally that RVRRTs can solve constrained problems with as many as 64 degrees of freedom and unconstrained problems with as many as 134 degrees of freedom. RVRRTs can solve problems more efficiently than existing methods, requiring fewer nodes and collision detection calls. We also show that it is capable of solving difficult problems that existing methods cannot.

  8. IS IT NECESSARY TO VACCINATE CHILDREN AGAINST HEPATITIS A ROUTINELY IN PRESENT TIME? THE EVALUATION OF RESULTS OF SUCH STRATEGY OF HEPATITIS A VACCINE PROPHYLAXIS IN SELECTED REGIONS OF THE RUSSIAN FEDERATION

    Directory of Open Access Journals (Sweden)

    I. V. Shakhgildian

    2011-01-01

    Full Text Available Abstract. Data about efficacy of conducting of routine vaccination of children against Hepatitis A are presented in the article. The results of realization such strategy of vaccine prevention of Hepatitis A in selected regions of Russian Federation are evaluated. The perspectives of using this experience in other regions of the country is discussed.

  9. Interactive Isogeometric Volume Visualization with Pixel-Accurate Geometry

    OpenAIRE

    Fuchs, Franz G.; Hjelmervik, Jon M.

    2014-01-01

    A recent development, called isogeometric analysis, provides a unified approach for design, analysis and optimization of functional products in industry. Traditional volume rendering methods for inspecting the results from the numerical simulations cannot be applied directly to isogeometric models. We present a novel approach for interactive visualization of isogeometric analysis results, ensuring correct, i.e., pixel-accurate geometry of the volume including its bounding surfaces. The entire...

  10. Eight light flavors on large lattice volumes

    CERN Document Server

    Schaich, David

    2013-01-01

    I present first results from large-scale lattice investigations of SU(3) gauge theory with eight light flavors in the fundamental representation. Using leadership computing resources at Argonne, we are generating gauge configurations with lattice volumes up to $64^3\\times128$ at relatively strong coupling, in an attempt to access the chiral regime. We use nHYP-improved staggered fermions, carefully monitoring finite-volume effects and other systematics. Here I focus on analyses of the light hadron spectrum and chiral condensate, measured on lattice volumes up to $48^3\\times96$ with fermion masses as light as m=0.004 in lattice units. We find no clear indication of spontaneous chiral symmetry breaking in these observables. I discuss the implications of these initial results, and prospects for further physics projects employing these ensembles of gauge configurations.

  11. Environmental Report 1995. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Harrach, R.J.; Failor, R.A.; Gallegos, G.M. [and others

    1996-09-01

    This report contains the results of Lawrence Livermore National Laboratory`s (LLNL) environmental monitoring and compliance effort and an assessment of the impact of LLNL operations on the environment and the public. This first volume describes LLNL`s environmental impact and compliance activities and features descriptive and explanatory text, summary data tables, and plots showing data trends. The summary data include measures of the center of data, their spread or variability, and their extreme values. Chapters on monitoring air, sewage, surface water, ground water, soil and sediment, vegetation and foodstuff, and environmental radiation are present.

  12. Computer vision technology in log volume inspection

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Log volume inspection is very important in forestry research and paper making engineering. This paper proposed a novel approach based on computer vision technology to cope with log volume inspection. The needed hardware system was analyzed and the details of the inspection algorithms were given. A fuzzy entropy based on image enhancement algorithm was presented for enhancing the image of the cross-section of log. In many practical applications the cross-section is often partially invisible, and this is the major obstacle for correct inspection. To solve this problem, a robust Hausdorff distance method was proposed to recover the whole cross-section. Experiment results showed that this method was efficient.

  13. The impacts of mantle phase transitions and the iron spin crossover in ferropericlase on convective mixing—is the evidence for compositional convection definitive? New results from a Yin-Yang overset grid-based control volume model

    Science.gov (United States)

    Shahnas, M. H.; Peltier, W. R.

    2015-08-01

    High-resolution seismic tomographic images from several subduction zones provide evidence for the inhibition of the downwelling of subducting slabs at the level of the 660 km depth seismic discontinuity. Furthermore, the inference of old (~140 Myr) sinking slabs below fossil subduction zones in the lower mantle has yet to be explained. We employ a control volume methodology to develop a new anelastically compressible model of three-dimensional thermal convection in the "mantle" of a terrestrial planet that fully incorporates the influence of large variations in material properties. The model also incorporates the influence of (1) multiple solid-solid pressure-induced phase transitions, (2) transformational superplasticity at 660 km depth, and (3) the high spin-low spin iron spin transition in ferropericlase at midmantle pressures. The message passing interface-parallelized code is successfully tested against previously published benchmark results. The high-resolution control volume models exhibit the same degree of radial layering as previously shown to be characteristic of otherwise identical 2-D axisymmetric spherical models. The layering is enhanced by the presence of moderate transformational superplasticity, and in the presence of the spin crossover in ferropericlase, stagnation of cold downwellings occurs in the range of spin crossover depths (~1700 km). Although this electronic spin transition has been suggested to be invisible seismically, recent high-pressure ab initio calculations suggest it to have a clear signature in body wave velocities which could provide an isochemical explanation of a seismological signature involving the onset of decorrelation between Vp and Vs that has come to be interpreted as requiring compositional layering.

  14. Study on Volume Strain Inversion from Water Level Change of Well-aquifer Systems

    Institute of Scientific and Technical Information of China (English)

    Yan Rui; Gao Fuwang; Chen Yong

    2008-01-01

    Based on linear poroelastic and hydrogcology theory, a mathematical expression describing the relationship between water level change and aquifer volume strain is put forward. Combined with earth tidal theory, we analyze the response characteristics from well-aquifer water level change to earth tide of volume strain and present a method of volume strain inversion from water level change. Comparing the results of inversion with real observed data, we found that there is a good consistency. This suggcsts that the method of volume strain inversion from water level change is proper. It will offer a reference for learning about hydrogeology characteristics, volume strain and searching for precursor anomalies.

  15. Beyond the floor effect on the Wechsler Intelligence Scale for Children--4th Ed. (WISC-IV): calculating IQ and Indexes of subjects presenting a floored pattern of results.

    Science.gov (United States)

    Orsini, A; Pezzuti, L; Hulbert, S

    2015-05-01

    It is now widely known that children with severe intellectual disability show a 'floor effect' on the Wechsler scales. This effect emerges because the practice of transforming raw scores into scaled scores eliminates any variability present in participants with low intellectual ability and because intelligence quotient (IQ) scores are limited insofar as they do not measure scores lower than 40. Following Hessl et al.'s results, the present authors propose a method for the computation of the Wechsler Intelligence Scale for Children--4th Ed. (WISC-IV)'s IQ and Indexes in intellectually disabled participants affected by a floored pattern of results. The Italian standardization sample (n = 2200) for the WISC-IV was used. The method presented in this study highlights the limits of the 'floor effect' of the WISC-IV in children with serious intellectual disability who present a profile with weighted scores of 1 in all the subtests despite some variability in the raw scores. Such method eliminates the floor effect of the scale and therefore makes it possible to analyse the strengths and weaknesses of the WISC-IV's Indexes in these participants. The Authors reflect on clinical utility of this method and on the meaning of raw score of 0 on subtest. © 2014 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  16. Compact Blue-Green Lasers: Summaries of Papers Presented at the Topical Meeting Held in Sante Fe, New Mexico on 20-21 February 1992. Volume 6. Technical Digest Series

    Science.gov (United States)

    1992-02-21

    genefrao.hm a needyri.. Iber laser. K. S. Buritaki, E. M. Dianov, V. A. Maslow , V. A. Chemy4ch, E. A. Shcharbekov, Geerwal Phyaic bntatlitue U.SSR. V. P...is necessary in order to achieve high macroscopic nonlinearity through electric poling. Due to the pyramidal sulfur center, the carbon oxygen bonds are...fle-buffer in sulfur cell ,the following results were ob.wrved. (i)SLable self- sustained glow discharge was first achieved with sulfur tempera- ture

  17. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume 1. Program summary

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    This report summarizes the Nonproliferation Alternative Systems Assessment Program (NASAP): its background, its studies, and its results. This introductory chapter traces the growth of the issue of nuclear weapons proliferation and the organization and objectives of NASAP. Chapter 2 summarizes the program's assessments, findings and recommendations. Each of Volumes II-VII reports on an individual assessment (Volume II: Proliferation Resistance; Volume III: Resources and Fuel Cycle Facilities; Volume IV: Commercial Potential; Volume V: Economics and Systems Analysis; Volume VI: Safety and Environmental Considerations for Licensing; Volume VII: International Perspectives). Volume VIII (Advanced Concepts) presents a combined assessment of several less fully developed concepts, and Volume IX (Reactor and Fuel Cycle Descriptions) provides detailed descriptions of the reactor and fuel-cycle systems studied by NASAP.

  18. Clinical presentation of juvenile Huntington disease

    Directory of Open Access Journals (Sweden)

    Ruocco Heloísa H.

    2006-01-01

    Full Text Available OBJECTIVE: To describe the clinical presentation a group of patients with juvenile onset of Huntington disease. METHOD: All patients were interviewed following a structured clinical questioner. Patients were genotyped for the trinucleotide cytosine-adenine-guanine (CAG repeat in the Huntington Disease gene. High resolution brain MRI was performed in all patients. RESULTS: We identified 4 patients with juvenile onset of disease among 50 patients with Huntington disease followed prospectively in our Neurogenetics clinic. Age at onset varied from 3 to 13 years, there were 2 boys, and 3 patients had a paternal inheritance of the disease. Expanded Huntington disease allele sizes varied from 41 to 69 trinucleotide repeats. The early onset patients presented with rigidity, bradykinesia, dystonia, dysarthria, seizures and ataxia. MRI showed severe volume loss of caudate and putamen nuclei (p=0.001 and reduced cerebral and cerebellum volumes (p=0.01. CONCLUSION: 8% of Huntington disease patients seen in our clinic had juvenile onset of the disease. They did not present with typical chorea as seen in adult onset Huntington disease. There was a predominance of rigidity and bradykinesia. Two other important clinical features were seizures and ataxia, which related with the imaging findings of early cortical atrophy and cerebellum volume loss.

  19. Volume reflection of ultrarelativistic particles in single crystals

    Directory of Open Access Journals (Sweden)

    V. A. Maisheev

    2007-08-01

    Full Text Available An analytical description of volume reflection of charged ultrarelativistic particles in bent single crystals is considered. The relation describing the angle of volume reflection as a function of the transversal energy is obtained. Different angle distributions of the scattered protons in single crystals are found. Results of calculations for 400 GeV protons scattered by the silicon single crystal are presented.

  20. Opinion presented on the behalf of the economic affairs commission on the finance bill for 2012: Volume 2: industry and energy; Avis presente au nom de la Commission des Affaires Economiques sur le projet de loi de finances pour 2012 (n. 3775), Tome 2 economie industrie et energie

    Energy Technology Data Exchange (ETDEWEB)

    Fioraso, G.

    2011-07-01

    The first part of this report deals with the actions of the French industrial policy as they are defined in the 2012 finance bill. The author (from the opposition party) presents the content of an action in favour of industrial firms within a program of firm and job development, and analyses its financing. She explains why she considers this policy as inadequate: lack of support for innovating small and medium enterprises, and lack of efficiency of public support. She proposes measures to support these innovating enterprises and to tighten the relationship between research and industry by the creation of industrial ecosystems. She presents Grenoble as an example of innovation in research and industry. The second part deals with energy. She presents various programs and actions, and analyses their financing. She discusses the consequences of the French situation with respect to nuclear energy, discusses the ways to struggle against climate change (priority to energy efficiency policies, investment in the development of the green sector, research and development in the carbon capture and storage techniques), and presents the development of the green sector as a way to phase out nuclear

  1. Volume arc therapy modulated for the ORL cancers. What results on the parotids with a single arc?; Arctherapie volumique modulee pour les cancers ORL. Quels resultats sur les parotides avec un arc unique?

    Energy Technology Data Exchange (ETDEWEB)

    Ailleres, N.; Rat, F.; Simeon, S.; Boisselier, P.; Azria, D.; Fenoglietto, P. [IRCM, Institut de Recherche en Cancerologie, 34 - Montpellier (France)

    2009-10-15

    For the O.R.L. cancers and although more in accordance with the volume than a classical conformal radiotherapy, the major interest of the I.M.R.T. is in the the possibility of critical organs preservation and principally the salivary parotids. however, the time necessary to the dose application is a limiting factor for some patients having difficulties to lie on the treatment table. The 'RapidArc' modality developed by the Varian society allows to apply the beam in a time close to one minute and a complete rotation around the patient. The question is then to know if this benefit of time is made to the detriment of quality of treatment plan. This technique with a dose modulation given by degree due to the mixture of the leaves movements, of the arm rotation speed and the rate variation, allows to get results similar or superior to those of I.M.R.T. with a treatment time and a very reduced number of monitor units. (N.C.)

  2. Hippocampal subfield volumes in mood disorders.

    Science.gov (United States)

    Cao, B; Passos, I C; Mwangi, B; Amaral-Silva, H; Tannous, J; Wu, M-J; Zunta-Soares, G B; Soares, J C

    2017-01-24

    Volume reduction and shape abnormality of the hippocampus have been associated with mood disorders. However, the hippocampus is not a uniform structure and consists of several subfields, such as the cornu ammonis (CA) subfields CA1-4, the dentate gyrus (DG) including a granule cell layer (GCL) and a molecular layer (ML) that continuously crosses adjacent subiculum (Sub) and CA fields. It is known that cellular and molecular mechanisms associated with mood disorders may be localized to specific hippocampal subfields. Thus, it is necessary to investigate the link between the in vivo hippocampal subfield volumes and specific mood disorders, such as bipolar disorder (BD) and major depressive disorder (MDD). In the present study, we used a state-of-the-art hippocampal segmentation approach, and we found that patients with BD had reduced volumes of hippocampal subfields, specifically in the left CA4, GCL, ML and both sides of the hippocampal tail, compared with healthy subjects and patients with MDD. The volume reduction was especially severe in patients with bipolar I disorder (BD-I). We also demonstrated that hippocampal subfield volume reduction was associated with the progression of the illness. For patients with BD-I, the volumes of the right CA1, ML and Sub decreased as the illness duration increased, and the volumes of both sides of the CA2/3, CA4 and hippocampal tail had negative correlations with the number of manic episodes. These results indicated that among the mood disorders the hippocampal subfields were more affected in BD-I compared with BD-II and MDD, and manic episodes had focused progressive effect on the CA2/3 and CA4 and hippocampal tail.Molecular Psychiatry advance online publication, 24 January 2017; doi:10.1038/mp.2016.262.

  3. 7th Annual CMMI Technology Conference Volume 3 Thursday Presentations

    Science.gov (United States)

    2007-11-15

    and Availability Management – Problem Management – Incident and Request Management 18 Sample Collaboration Agreement Templates • Sample Templates...small projects in – software development functional area (CMMI, PMBOK)) – managed services functional area (ISO 20000, ITIL , PMBOK) • Staff augmentation...support CMMI, ISO 20000 ( ITIL ), PMBOK best practices • EITS measurement process assets must be tailorable to diverse functional areas ( managed

  4. Military Compensation: Past, Present and Future. Volume 1. Executive Summary.

    Science.gov (United States)

    1976-01-01

    work may serve the Army, its people, and the Nation. Acession For * DTIC TAB Unannounced 0 JustificatioLon Bylbrx LM. ou le Dist ribut on/S...food, water, shelter, clothing, and medicines . It was the Army that literally "opened up" the western United States after the Nation acquired the...industry as well. 1 9 Army contributions to the field of medicine and the allevia- tion of human suffering have been monunental. In 1899, Amy Lieutenant

  5. [Clinical and economical comparison between in-house (Make) and outsourcing (Buy) management of the cardiac catheterization laboratory from two high-volume diagnostic and interventional centers: immediate and 6-month results].

    Science.gov (United States)

    Varbella, Ferdinando; Minniti, Davide; Belli, Riccardo; Gualano, Maria Rosaria; Tomassini, Francesco; Gagnor, Andrea; Gambino, Alfonso; Tizzani, Emanuele; Montali, Nicolò; Ceruti, Michele; Gianino, Maria Michela

    2014-04-01

    Percutaneous coronary interventions (PCI) are widespread procedures in the Italian Healthcare System, but concerns are raised about their economic sustainability. In the last decade, public hospitals have outsourced the PCI services (building and maintaining the technological instruments and the personnel) "buying" them from private companies (Buy) rather than building and maintaining them through public expenditure (Make). The aim of this study was to compare the economic and clinical impact of these two management solutions (Buy and Make) in two community hospitals located in the Turin metropolitan area (Italy). We conducted: 1) a quantitative assessment in order to compare differences in the economic impact between Buy and Make for providing PCI; 2) a qualitative assessment comparing the clinical characteristics of two inpatient populations undergoing PCI and then analyzing the efficacy of the procedure in-hospital and at 6-month follow-up. Between January and June 2010, a total of 332 patients underwent PCI at the "degli Infermi" Hospital in Rivoli and 340 at the "Maria Vittoria" Hospital in Turin (Italy). There were no significant differences between the two populations neither about the clinical characteristics nor in procedural efficacy (either immediate or at follow-up). For 600 units of diagnostic-therapeutic pathway, the net present value at a discount rate of 3.5% of the Make project is higher than that of the Buy by €278.402,25, and is therefore the less convenient of the two solutions. The Buy solution is still the more convenient of the two at volumes <700 units. Our findings show that the Buy solution, if tailored to the specific local needs, provides access to sophisticated technology without making worse quality of services and may save capital expenditure below 700 PCI/years.

  6. Discretized Volumes in Numerical Methods

    CERN Document Server

    Antal, Miklós

    2007-01-01

    We present two techniques novel in numerical methods. The first technique compiles the domain of the numerical methods as a discretized volume. Congruent elements are glued together to compile the domain over which the solution of a boundary value problem is sought. We associate a group and a graph to that volume. When the group is symmetry of the boundary value problem under investigation, one can specify the structure of the solution, and find out if there are equispectral volumes of a given type. The second technique uses a complex mapping to transplant the solution from volume to volume and a correction function. Equation for the correction function is given. A simple example demonstrates the feasibility of the suggested method.

  7. Site Environmental Report for 2005 Volume I and Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Ruggieri, Michael

    2006-07-07

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, ''Environment, Safety, and Health Reporting''. The ''Site Environmental Report for 2005'' summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2005. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as ''Berkeley Lab'', ''the Laboratory'', ''Lawrence Berkeley National Laboratory'', and ''LBNL''.) The report is separated into two volumes. Volume I contains an overview of the Laboratory, the status of environmental programs, and summarized results from surveillance and monitoring activities. This year's Volume I text body is organized into an executive summary followed by six chapters. The report's structure has been reorganized this year, and it now includes a chapter devoted to environmental management system topics. Volume II contains individual data results from surveillance and monitoring activities. The ''Site Environmental Report'' is distributed by releasing it on the Web from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at http://www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. CD and printed copies of this Site Environmental Report are available upon request. The report follows the Laboratory's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are also reported using the more conventional (non-SI) system of measurements, because the non-SI system is referenced by several current

  8. Comparing Volumes of Prisms and Pyramids

    Science.gov (United States)

    Vinogradova, Natalya

    2012-01-01

    Students' experience in using formulas for volumes is often limited to substituting numbers into given formulas. An activity presented in this article may help students make connections between the formulas for volumes of prisms and volumes of pyramids. In addition, some interesting facts from number theory arise, demonstrating strong connections…

  9. Photogrammetry and Laser Imagery Tests for Tank Waste Volume Estimates: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Field, Jim G. [Washington River Protection Solutions, LLC, Richland, WA (United States)

    2013-03-27

    Feasibility tests were conducted using photogrammetry and laser technologies to estimate the volume of waste in a tank. These technologies were compared with video Camera/CAD Modeling System (CCMS) estimates; the current method used for post-retrieval waste volume estimates. This report summarizes test results and presents recommendations for further development and deployment of technologies to provide more accurate and faster waste volume estimates in support of tank retrieval and closure.

  10. Well-balanced finite volume evolution Galerkin methods for the shallow water equations

    OpenAIRE

    Medvidová, Maria Lukáčová -; Noelle, Sebastian; Kraft, Marcus

    2015-01-01

    We present a new well-balanced finite volume method within the framework of the finite volume evolution Galerkin (FVEG) schemes. The methodology will be illustrated for the shallow water equations with source terms modelling the bottom topography and Coriolis forces. Results can be generalized to more complex systems of balance laws. The FVEG methods couple a finite volume formulation with approximate evolution operators. The latter are constructed using the bicharacteristics of multidimensio...

  11. Finite volume schemes for multi-dimensional hyperbolic systems based on the use of bicharacteristics

    OpenAIRE

    Lukácová-Medvid'ová, Maria; Saibertova, Jitka

    2004-01-01

    In this paper we present recent results for the bicharacteristic based finite volume schemes, the so-called finite volume evolution Galerkin (FVEG) schemes. These methods were proposed to solve multi-dimensional hyperbolic conservation laws. They combine the usually conflicting design objectives of using the conservation form and following the characteristics, or bicharacteristics. This is realized by combining the finite volume formulation with approximate evolution operators, which use bich...

  12. Finite volume schemes for multidimensional hyperbolic systems based on the use of bicharacteristics

    OpenAIRE

    Lukácová-Medvid'ová, Maria

    2003-01-01

    In this survey paper we present an overview on recent results for the bicharacteristics based finite volume schemes, the so-called finite volume evolution Galerkin (FVEG) schemes. These methods were proposed to solve multidimensional hyperbolic conservation laws. They combine the usually conflicting design objectives of using the conservation form and following the characteritics, or bicharacteritics. This is realized by combining the finite volume formulation with approximate evolution opera...

  13. Well-balanced finite volume evolution Galerkin methods for the shallow water equations

    OpenAIRE

    Lukácová-Medvid'ová, Maria; Kraft, Marcus

    2005-01-01

    We present a new well-balanced finite volume method within the framework of the finite volume evolution Galerkin (FVEG) schemes. The methodology will be illustrated for the shallow water equations with source terms modelling the bottom topography and Coriolis forces. Results can be generalized to more complex systems of balance laws. The FVEG methods couple a finite volume formulation with approximate evolution operators. The latter are constructed using the bicharacteristics of the multidime...

  14. Cell Volume Regulation and Apoptotic Volume Decrease in Rat Distal Colon Superficial Enterocytes

    Directory of Open Access Journals (Sweden)

    Stefania Antico

    2013-12-01

    Full Text Available Background: The colon epithelium is physiologically exposed to osmotic stress, and the activation of cell volume regulation mechanisms is essential in colonocyte physiology. Moreover, colon is characterized by a high apoptotic rate of mature cells balancing the high division rate of stem cells. Aim: The aim of the present work was to investigate the main cell volume regulation mechanisms in rat colon surface colonocytes and their role in apoptosis. Methods: Cell volume changes were measured by light microscopy and video imaging on colon explants; apoptosis sign appearance was monitored by confocal microscopy on annexin V/propidium iodide labeled explants. Results: Superficial colonocytes showed a dynamic regulation of their cell volume during anisosmotic conditions with a Regulatory Volume Increase (RVI response following hypertonic shrinkage and Regulatory Volume Decrease (RVD response following hypotonic swelling. RVI was completely inhibited by bumetanide, while RVD was completely abolished by high K+ or iberiotoxin treatment and by extracellular Ca2+ removal. DIDS incubation was also able to affect the RVD response. When colon explants were exposed to H2O2 as apoptotic inducer, colonocytes underwent an isotonic volume decrease ascribable to Apoptotic Volume Decrease (AVD within about four hours of exposure. AVD was shown to precede annexin V positivity. It was also inhibited by high K+ or iberiotoxin treatment. Interestingly, treatment with iberiotoxin significantly inhibited apoptosis progression. Conclusions: In rat superficial colonocytes K+ efflux through high conductance Ca2+-activated K+ channels (BK channels was demonstrated to be the main mechanism of RVD and to plays also a crucial role in the AVD process and in the progression of apoptosis.

  15. Variation in radiotherapy target volume definition, dose to organs at risk and clinical target volumes using anatomic (computed tomography) versus combined anatomic and molecular imaging (positron emission tomography/computed tomography): intensity-modulated radiotherapy delivered using a tomotherapy Hi Art machine: final results of the VortigERN study.

    Science.gov (United States)

    Chatterjee, S; Frew, J; Mott, J; McCallum, H; Stevenson, P; Maxwell, R; Wilsdon, J; Kelly, C G

    2012-12-01

    Contrast-enhanced computed tomography (CECT) is the current standard for delineating tumours of the head and neck for radiotherapy. Although metabolic imaging with positron emission tomography (PET) has been used in recent years, the studies were non-confirmatory in establishing its routine role in radiotherapy planning in the modern era. This study explored the difference in gross tumour volume and clinical target volume definitions for the primary and nodal volumes when FDG PET/CT was used as compared with CECT in oropharyngeal cancer cases. Twenty patients with oropharyngeal cancers had a PET/CT scan in the treatment position after consent. Target volumes were defined on CECT scans by a consultant clinical oncologist who was blind to the PET scans. After obtaining inputs from a radiologist, another set of target volumes were outlined on the PET/CT data set. The gross and clinical target volumes as defined on the two data sets were then analysed. The hypothesis of more accurate target delineation, preventing geographical miss and comparative overlap volumes between CECT and PET/CT, was explored. The study also analysed the volumes of intersection and analysed whether there was any TNM stage migration when PET/CT was used as compared with CECT for planning. In 17 of 20 patients, the TNM stage was not altered when adding FDG PET information to CT. PET information prevented geographical miss in two patients and identified distant metastases in one case. PET/CT gross tumour volumes were smaller than CECT volumes (mean ± standard deviation: 25.16 cm(3) ± 35.8 versus 36.56 cm(3) ± 44.14; P 0.86) were not statistically different. Similarity and discordance coefficients were calculated and are reported. PET/CT as compared with CECT could provide more clinically relevant information and prevent geographical miss when used for radiotherapy planning for advanced oropharyngeal tumours. Also, PET/CT provided a smaller better-defined target volume when compared with CECT

  16. Use of double-layer autologous dermal flap in the treatment of recurrent and/or infected incisional hernias: presentation of the surgical technique and the results of 1-year follow-up-a prospective, consecutive cohort study.

    Science.gov (United States)

    Martis, G; Damjanovich, L

    2016-06-01

    The difficulties of treating recurrent and/or infected incisional hernias are well known in surgical practice. Several surgical techniques and various types of grafts are available for surgeons. This study presents a new surgical technique option together with the results of the 1-year follow-up. The primary aim of the study is to present the surgical technique of the procedure suitable for the treatment of recurrent and/or infected incisional hernias. The secondary aim is to determine the recurrence rate and analyse the surgical complications. The tertiary aim is to present the quality of life test results performed 3, 6 and 12 months after the surgery. The authors evaluated the results of 36 recurrent and/or infected incisional hernia surgeries (11 men, average age 60.6 years; 25 women, average age 58.9 years) performed with their own surgical method in the framework of a tightly controlled, prospective, interventional and observational consecutive cohort study conducted between 1 January 2011 and 31 December 2013 at a university surgical department. The study evaluates the results of the 1-year follow-up period. All 36 patients had at least one recurrence of abdominal wall hernia; 12 of them also had concurrent infection of the synthetic graft and a complicating fistula. The mean BMI was 31.82 kg/m(2) (25.2-43.5 kg/m(2)). The average size of the abdominal wall defect was 145.9 cm(2) (59-275 cm(2)). The abdominal wall reconstruction was performed using an autologous, double-layer dermal flap. The grafts, which had been inserted during previous surgeries, were removed completely. The autologous dermal tissue was prepared using the flap harvested during dermolipectomy. The reconstruction was achieved using a tension-free technique. The essence of the abdominal wall reconstruction is the completion of the abdominal wall defect by a double-layer autologous dermal flap. The original abdominal wall defect was not closed by direct sutures. The quality of the

  17. Videoradiography of patients with habitual snoring and/or sleep apnea. Technical description and presentation of videoradiographic results during sleep concerning occurrence of apnea, type of apnea, and site of obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Hillarp, B. [Dept. of Diagnostic Radiology, Malmoe Univ. Hospital (Sweden); Nylander, G. [Dept. of Diagnostic Radiology, Malmoe Univ. Hospital (Sweden); Rosen, I. [Dept. of Neurophysiology, Malmoe Univ. Hospital (Sweden); Wickstroem, O. [Dept. of Neurophysiology, Malmoe Univ. Hospital (Sweden)

    1995-05-01

    The videoradiographic examination described was designed for habitual snorers and sleep apnea syndrome (SAS) patients and was performed during wakefulness and sleep. During wakefulness the purpose was to reveal any dysfunction in deglutiton and speech as well as morphologic abnormalities. The purpose during sleep, which usually was induced by low-dose midazolam intravenously, was to reveal the site and form of obstruction in obstructive sleep apnea patients and the site of snoring in habitual snorers. The preoperative results of 104 patients are presented. In 57 patients who had apneas, the occurrence and type of apnea could be determined. A continuous recording over some minutes gave a rough estimate of the degree of SAS and mean duration of apnea. Although much information on SAS can be obtained by this method, it cannot replace polygraphic sleep recording in the investigation of habitual snorers and SAS patients. However, these 2 methods are complementary and can be performed simultaneously as polygraphic videoradiography. (orig.).

  18. Opinion presented on behalf of the Economical Affairs Commission on the finance bill for 2010 (n. 1946) - Volume II: Sustainable ecology, development and planning. Industry and energy; Avis presente au nom de la Commission des Affaires Economiques sur le projet de loi de finances pour 2010 (n.1946), tome 2 ecologie, developpement et amenagement durables industrie et energie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-10-15

    This report of the French National Assembly first presents the different programmes and actions related to energy and industry for which credits are foreseen in the French finance bill for 2010: development of firms and employment, energy policy, after-mining policy, struggle against climate change, management of ecology, energy, sustainable development, and sea policies, research in the field of energy and sustainable development and planning. The author then outlines the importance of the creation of conditions for a green growth in order to cope with an unprecedented crisis which ruins industrial employment. This implies the support of strategic sectors (energy-efficient building, evolution towards green chemistry, photovoltaic solar energy, renewable heat, innovating vehicles), the implementation of new priorities (smart grids, management of raw materials), and the emergence of ecological technologies promoted by the new tools of a climate policy (carbon tax introduction, improvement of carbon markets). It also implies an industrial output for research by means of a networking of actors (development of competitiveness poles, participation to European partnerships), and a reinforcement of the industrial horizon in the research policy (patenting, start-up development, support to innovating small and middle-sized companies, implementation of a true French capital-risk sector)

  19. Changes of pituitary gland volume in Kennedy disease.

    Science.gov (United States)

    Pieper, C C; Teismann, I K; Konrad, C; Heindel, W L; Schiffbauer, H

    2013-12-01

    Kennedy disease is a rare X-linked neurodegenerative disorder caused by a CAG repeat expansion in the first exon of the androgen-receptor gene. Apart from neurologic signs, this mutation can cause a partial androgen insensitivity syndrome with typical alterations of gonadotropic hormones produced by the pituitary gland. The aim of the present study was therefore to evaluate the impact of Kennedy disease on pituitary gland volume under the hypothesis that endocrinologic changes caused by partial androgen insensitivity may lead to morphologic changes (ie, hypertrophy) of the pituitary gland. Pituitary gland volume was measured in sagittal sections of 3D T1-weighted 3T-MR imaging data of 8 patients with genetically proven Kennedy disease and compared with 16 healthy age-matched control subjects by use of Multitracer by a blinded, experienced radiologist. The results were analyzed by a univariant ANOVA with total brain volume as a covariant. Furthermore, correlation and linear regression analyses were performed for pituitary volume, patient age, disease duration, and CAG repeat expansion length. Intraobserver reliability was evaluated by means of the Pearson correlation coefficient. Pituitary volume was significantly larger in patients with Kennedy disease (636 [±90] mm(3)) than in healthy control subjects (534 [±91] mm(3)) (P = .041). There was no significant difference in total brain volume (P = .379). Control subjects showed a significant decrease in volume with age (r = -0.712, P = .002), whereas there was a trend to increasing gland volume in patients with Kennedy disease (r = 0.443, P = .272). Gland volume correlated with CAG repeat expansion length in patients (r = 0.630, P = .047). The correlation coefficient for intraobserver reliability was 0.94 (P pituitary volume that correlated with the CAG repeat expansion length. This could reflect hypertrophy as the result of elevated gonadotropic hormone secretion caused by the androgen receptor mutation with partial

  20. Delinquent behavior among young people in the western world : First results of the international self-report delinquency study

    NARCIS (Netherlands)

    Junger-Tas, J.; Terlouw, G.-J.; Klein, M.W.

    1994-01-01

    This volume presents the first results of the self-report in 13 individual countries. A second volume will follow in 1995, which will present the results of in-depth comparative analysis. The outcomes of these studies are presented in individual chapters. Some conclusions on the basis of this

  1. Importance of volume corrections on the net-charge distributions at the RHIC BES energies

    CERN Document Server

    Xu, Hao-jie

    2016-01-01

    The paper presents my recent investigations of volume corrections on the cumulant products of net-charge distributions in statistical model, corresponding to the data reported by the STAR collaboration. The corrected statistical expectations, under simple Poisson approximations, can reasonably explain the data measured in experiment. The results indicate that volume corrections play crucial role in event-by-event multiplicity fluctuation studies.

  2. Finite element procedure for stress amplification factor recovering in a representative volume of composite materials

    Directory of Open Access Journals (Sweden)

    Paulo Cesar Plaisant Junior

    2011-09-01

    Full Text Available Finite element models are proposed to the micromechanical analysis of a representative volume of composite materials. A detailed description of the meshes, boundary conditions, and loadings are presented. An illustrative application is given to evaluate stress amplification factors within a representative volume of the unidirectional carbon fiber composite plate. The results are discussed and compared to the numerical findings.

  3. Analysis of technologies for natural gas transportation in Brazil: results comparison of the application of payback and NPV (Net Present Value) methods; Analise de tecnologias de transporte de gas natural no Brasil: comparacao dos resultados da aplicacao dos metodos 'payback' e VPL (Valor Presente Liquido)

    Energy Technology Data Exchange (ETDEWEB)

    Baioco, Juliana Souza; Santarem, Clarissa Andrade [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Engenharia de Petroleo; Bone, Rosemarie Broeker; Ferreira Filho, Virgilio Jose Martins [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Engenharia Industrial

    2008-07-01

    The increased demand for natural gas leads to global integration of markets, leading to decisions that cover the various technologies of transportation, noting the specific locations. The transport of natural gas considered more traditional (Liquefied Natural Gas and Pipeline) often unviable economically areas of operation due to cost. In this case, there are alternative technologies to reduce those costs. The article is to compare the technologies of transport, using the methodology of the Net Present Value (VPL) to identify one that has more positive VPL, which is the most profitable. Thus, in search of validate the results of SUBERO et al. (2004) for gas transport by Pipelines, Liquefied Natural Gas and Compressed Natural Gas. In addition, they are compared these results with the method of VPL and with the economic analysis presented in using the payback period of CHANG (2001) and SANTAREM et al. (2007). It was found that the results obtained in Brazil were identical to those obtained by CHANG (2001) and SUBERO et al. (2007), saving only some differences in magnitude due to the specific characteristics of the Brazilian economy. In other words, for the Brazilian case, the technology of Compressed Natural Gas (CNG) was the most economically viable with the method of VPL, followed by technology, Pipeline and Liquefied Natural Gas (LNG), regardless of the interest rates of 10% and 6.5% and periods of 20 and 30 years. The contribution of this work is to show that despite of the method, payback or VPL, the various alternatives for transporting natural gas to Brazil have the same ranking and economic viability. (author)

  4. The effects of section thickness on the estimation of liver volume by the Cavalieri principle using computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Emirzeoglu, Mehmet [Department of Anatomy, Medical School, Ondokuz Mayis University, Samsun 55139 (Turkey); Sahin, Bunyamin [Department of Anatomy, Medical School, Ondokuz Mayis University, Samsun 55139 (Turkey)]. E-mail: bsahin@omu.edu.tr; Selcuk, Mustafa B. [Department of Radiology, Medical School, Ondokuz Mayis University, Samsun 55139 (Turkey); Kaplan, Suleyman [Department of Histology and Embryology, Medical School, Ondokuz Mayis University, Samsun 55139 (Turkey)

    2005-12-15

    Estimation of liver volume using routine CT scans has been described previously. We have, however, not found a gold standard study which analyzes the effect of section thickness on the estimation of liver volume using CT images. In the present study, five normal livers obtained from cadavers were scanned using a Spiral CT Scanner (Xpress/GX Toshiba, Tocigi-Ken) in the horizontal plane. Consecutive sections at a thickness of 10, 5 and 1 mm were used to estimate the total volume of the livers by means of the Cavalieri principle. With a view to evaluating inter-observer differences, liver volume was estimated by three observers. The estimated volume using the classical volume estimation formula did not concur with the actual volume of the livers obtained by the fluid displacement technique. The section thickness has an over- or under-projection effect on the estimated volume. The obtained volume estimation results were, therefore, calibrated using three different approaches. The volume obtained by the calibration formulae did not differ statistically from actual liver volumes (P < 0.05). There were also no significant differences between the performers' estimates (P > 0.05). Results showed that the effect of section thickness on the volume estimates could not be omitted and the obtained values could be calibrated using the proposed approaches presented in this study.

  5. Animation framework using volume visualization

    Science.gov (United States)

    Fang, Wenxuan; Wang, Hongli

    2004-03-01

    As the development of computer graphics, scientific visualization and advanced imaging scanner and sensor technology, high quality animation making of volume data set has been a challenging in industries. A simple animation framework by using current volume visualization techniques is proposed in this paper. The framework consists of two pipelines: one is surface based method by using marching cubes algorithm, the other is volume rendering method by using shear-warp method. The volume visualization results can not only be used as key frame sources in the animation making, but also can be directly used as animation when the volume visualization is in stereoscopic mode. The proposed framework can be applied into fields such as medical education, film-making and archaeology.

  6. Opinion presented on behalf of the Economic Affairs Commission on the Finance bill for 2011 (n. 2824), volume 2 Ecology, Sustainable Development and Land Planning, industry and energy; Avis presente au nom de la Commission des Affaires Economiques sur le projet de loi de finances pour 2011 (n. 2824), tome 2 ecologie, developpement et amenagement durables industrie et energie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    In her introduction, the author gives a description of the difficult context and situation faced by the industrial sector in France, notably because of the growing activity of emerging countries like China, India or Brazil, but also because of the weakness of research industrial valorization and of the innovation policy (losing the manufacturing capacity leads to losing the capacity for innovation). Then, after a critic of the current policy (reform of the professional tax, a boosting plan with limited results), she comments the contents of public programmes concerning firm and job development, energy, the steering of ecology, energy, sustainable development and sea policies, research in energy and sustainable development and land planning. She comments ways and tools aimed at supporting industrial jobs through innovation: the FSI (strategic investment fund), the competitiveness poles, specific aids to small and medium sized enterprises, tax credit related to research activities. She addresses the energy sector, questioning the French supremacy in the nuclear energy and the increase of electricity price, and criticizing the management of the development of renewable energies (high expenses for no industrial development)

  7. Surface and Volume Grid Generation in Parametric Form

    Science.gov (United States)

    Yu, Tzuyi; Soni, Bharat K.; Benjamin, Ted; Williams, Robert

    1996-01-01

    The algorithm for surface modeling and volume grid generation using parametric Non-Uniform Rational B-splines (NURBS) geometric representation are presented. The enhanced re-parameterization algorithm which can yield a desired physical distribution on the curve, surface, and volume is also presented. This approach bridges the gap between computer aided design surface/volume definition and surface/volume grid generation.

  8. Use of a theoretical equation of state to interpret time-dependent free volume in polymer glasses

    Energy Technology Data Exchange (ETDEWEB)

    Curro, J.G.; Lagasse, R.R.; Simha, R.

    1981-10-01

    Many physical properties of polymer glasses change spontaneously during isothermal aging by a process commonly modeled as collapse of free volume. The model has not been verified rigorously because free volume cannot be unambiguously measured. In the present investigation we tentatively identify the free-volume fraction with the fraction of empty sites in the equation of state of Simha and Somcynsky. With this theory, volume recovery measurements can be analyzed to yield directly the time-dependent, free-volume fraction. Using this approach, recent volume measurements on poly(methyl methacrylate) are analyzed. The resulting free-volume fractions are then used in the Doolittle equation to predict the shift in stress relaxation curves at 23 /sup 0/C. These predicted shift factors agree with the experimental measurements of Cizmecioglu et al. In addition, it is shown that previous assumptions concerning temperature dependence of free volume are inconsistent with the theory.

  9. Use of a theoretical equation of state to interpret time-dependent free volume in polymer glasses

    Science.gov (United States)

    Curro, J. G.; Lagasse, R. R.; Simha, R.

    1981-10-01

    Many physical properties of polymer glasses change spontaneously during isothermal aging by a process commonly modeled as collapse of free volume. The model has not been verified rigorously because free volume cannot be unambiguously measured. In the present investigation we tentatively identify the free-volume fraction with the fraction of empty sites in the equation of state of Simha and Somcynsky. With this theory, volume recovery measurements can be analyzed to yield directly the time-dependent, free-volume fraction. Using this approach, recent volume measurements on poly(methyl methacrylate) are analyzed. The resulting free-volume fractions are then used in the Doolittle equation to predict the shift in stress relaxation curves at 23 °C. These predicted shift factors agree with the experimental measurements of Cizmecioglu et al. In addition, it is shown that previous assumptions concerning temperature dependence of free volume are inconsistent with the theory.

  10. Sound and computer information presentation

    Energy Technology Data Exchange (ETDEWEB)

    Bly, S

    1982-03-01

    This thesis examines the use of sound to present data. Computer graphics currently offers a vast array of techniques for communicating data to analysts. Graphics is limited, however, by the number of dimensions that can be perceived at one time, by the types of data that lend themselves to visual representation, and by the necessary eye focus on the output. Sound offers an enhancement and an alternative to graphic tools. Multivariate, logarithmic, and time-varying data provide examples for aural representation. For each of these three types of data, the thesis suggests a method of encoding the information into sound and presents various applications. Data values were mapped to sound characteristics such as pitch and volume so that information was presented as sets or sequences of notes. In all cases, the resulting sounds conveyed information in a manner consistent with prior knowledge of the data. Experiments showed that sound does convey information accurately and that sound can enhance graphic presentations. Subjects were tested on their ability to distinguish between two sources of test items. In the first phase of the experiments, subjects discriminated between two 6-dimensional data sets represented in sound. In the second phase of the experiment, 75 subjects were selected and assigned to one of three groups. The first group of 25 heard test items, the second group saw test items, and the third group both heard and saw the test items. The average percentage correct was 64.5% for the sound-only group, 62% for the graphics-only group, and 69% for the sound and graphics group. In the third phase, additional experiments focused on the mapping between data values and sound characteristics and on the training methods.

  11. Programs to obtain vertical heights from mean sea level and for computing volume of sand/mineral along beaches: A case study with Kalbadevi beach profiling data and results

    Digital Repository Service at National Institute of Oceanography (India)

    Ganesan, P.

    Two programs have been developed to process profile data, for obtaining vertical heights with respect to mean sea level (M.S.L.) and for computation of volume of heavy mineral / sand accumulation or erosion along the beaches. The final output...

  12. Sequential (gemcitabine/vinorelbine and concurrent (gemcitabine radiochemotherapy with FDG-PET-based target volume definition in locally advanced non-small cell lung cancer: first results of a phase I/II study

    Directory of Open Access Journals (Sweden)

    Stanzel Sven

    2007-06-01

    Full Text Available Abstract Background The aim of the study was to determine the maximal tolerated dose (MTD of gemcitabine every two weeks concurrent to radiotherapy, administered during an aggressive program of sequential and simultaneous radiochemotherapy for locally advanced, unresectable non-small cell lung cancer (NSCLC and to evaluate the efficacy of this regime in a phase II study. Methods 33 patients with histologically confirmed NSCLC were enrolled in a combined radiochemotherapy protocol. 29 patients were assessable for evaluation of toxicity and tumor response. Treatment included two cycles of induction chemotherapy with gemcitabine (1200 mg/m2 and vinorelbine (30 mg/m2 at day 1, 8 and 22, 29 followed by concurrent radiotherapy (2.0 Gy/d; total dose 66.0 Gy and chemotherapy with gemcitabine every two weeks at day 43, 57 and 71. Radiotherapy planning included [18F] fluorodeoxyglucose positron emission tomography (FDG PET based target volume definition. 10 patients were included in the phase I study with an initial gemcitabine dose of 300 mg/m2. The dose of gemcitabine was increased in steps of 100 mg/m2 until the MTD was realized. Results MTD was defined for the patient group receiving gemcitabine 500 mg/m2 due to grade 2 (next to grade 3 esophagitis in all patients resulting in a mean body weight loss of 5 kg (SD = 1.4 kg, representing 8% of the initial weight. These patients showed persisting dysphagia 3 to 4 weeks after completing radiotherapy. In accordance with expected complications as esophagitis, dysphagia and odynophagia, we defined the MTD at this dose level, although no dose limiting toxicity (DLT grade 3 was reached. In the phase I/II median follow-up was 15.7 months (4.1 to 42.6 months. The overall response rate after completion of therapy was 64%. The median overall survival was 19.9 (95% CI: [10.1; 29.7] months for all eligible patients. The median disease-free survival for all patients was 8.7 (95% CI: [2.7; 14.6] months. Conclusion

  13. Determination of volumes in pipeline drain operation; Determinacao de volumes em operacao de drenagem de oleodutos

    Energy Technology Data Exchange (ETDEWEB)

    Pires, Luis Fernando G.; Barreto, Claudio V.; Silva, Bruno G. de [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica. Nucleo de Simulacao Termohidraulica de Dutos - SIMDUT

    2005-07-01

    Usually, pipeline and equipment maintenance requires the partial or fully drainage of the line. To develop this operation, it is necessary to preview the volumes at the drainage points to allocate the available resources to remove the liquid. With this main objective it was developed a numerical tool that is able to calculate the drainage volumes using only the data source from the GIS profile. This is possible if we consider a pipeline at no-flow state where only the gravitational forces can act in the fluid. The present paper uses a spreadsheet to determine the product volumes based in the drain points sequence and considering no flow boundaries along the pipeline. To validate the methodology a comparison is done with the results acquired in two real state drainage operations. (author)

  14. The study of volume ultrasonic waves propagation in the gas-containing iron ore pulp.

    Science.gov (United States)

    Morkun, V; Morkun, N; Pikilnyak, A

    2015-02-01

    The results of research of the volume ultrasonic waves propagation in the gas-containing iron ore slurry using ultrasonic phased array technology is presented. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Regulation of amniotic fluid volume.

    Science.gov (United States)

    Beall, M H; van den Wijngaard, J P H M; van Gemert, M J C; Ross, M G

    2007-01-01

    Water arrives in the mammalian gestation from the maternal circulation across the placenta. It then circulates between the fetal water compartments, including the fetal body compartments, the placenta and the amniotic fluid. Amniotic fluid is created by the flow of fluid from the fetal lung and bladder. A major pathway for amniotic fluid resorption is fetal swallowing; however, in many cases the amounts of fluid produced and absorbed do not balance. A second resorption pathway, the intramembranous pathway (across the amnion to the fetal circulation), has been proposed to explain the maintenance of normal amniotic fluid volume. Amniotic fluid volume is thus a function both of the amount of water transferred to the gestation across the placental membrane, and the flux of water across the amnion. Water flux across biologic membranes may be driven by osmotic or hydrostatic forces; existing data suggest that intramembranous flow in humans is driven by the osmotic difference between the amniotic fluid and the fetal serum. The driving force for placental flow is more controversial, and both forces may be in effect. The mechanism(s) responsible for regulating water flow to and from the amniotic fluid is unknown. In other parts of the body, notably the kidney, water flux is regulated by the expression of aquaporin water channels on the cell membrane. We hypothesize that aquaporins have a role in regulating water flux across both the amnion and the placenta, and present evidence in support of this theory. Current knowledge of gestational water flow is sufficient to allow prediction of fetal outcome when water flow is abnormal, as in twin-twin transfusion syndrome. Further insight into these mechanisms may allow novel treatments for amniotic fluid volume abnormalities with resultant improvement in clinical outcome.

  16. Switching from human insulin to biphasic insulin aspart 30 treatment gets more patients with type 2 diabetes to reach target glycosylated hemoglobin 《7%: the results from the China cohort of the PRESENT study

    Institute of Scientific and Technical Information of China (English)

    GAO Yan; GUO Xiao-hui

    2010-01-01

    Background The clinical importance of glycaemic control in patients with diabetes has been well established. This study aimed to explore twice-daily biphasic insulin aspart 30 (BIAsp 30) for insulin initiation in patients with type 2 diabetes mellitus (T2DM) who had poor glycaemic control with human insulins (His). We use data from a Chinese cohort of the PRESENT study.Methods In the 3-month study, Chinese subjects with T2DM started insulin therapy with BIAsp 30 in routine care. Glycaemic control was measured by glycosylated hemoglobin (HbA1c), fasting plasma glucose (FPG) and posting plasma glucose (PPG). The safety assessment included hypoglycaemia and other adverse events.Results A total of 1989 subjects previously treated with His were switched to BIAsp 30 for 3-month treatment. Mean HbA1c, FPG and PPG were significantly improved after the therapy. The overall rate of hypoglycaemia decreased at the end of the trial except for the patients previously treated with long-acting insulin. Most of the events were minor and diurnal hypoglycaemia. Only one serious adverse drug reaction (SADR), a local hypersensitivity, was reported. The majority of the patients (296.7%) and physicians (≥84.7%) were either satisfied or very satisfied with the treatment using BIAsp 30 compared with previous HI therapy.Conclusion The BIAsp 30 treatment improved both glycaemic control and patients' satisfaction without increasing hypoglycaemia in T2DM subjects inadequately controlled by Hls.

  17. Influence of insufficient blood specimens volume on the detection results of coagulation tests in SD rats%SD 大鼠标本血量不足对凝血四项检测结果的影响

    Institute of Scientific and Technical Information of China (English)

    翟青新; 黄爱军; 钱丽萍

    2015-01-01

    whole blood (vlume∶volume)]1∶9(the control group)and 1∶5( the experimental group),1∶8( the experimental group) and 1∶7( the experimental group).Get plasma without platelet through centrifugation.Fully automatic blood coagulation analyzer detected prothrombin time , activated partial thromboplatin time , thrombin time and Fibrinogen.Results HCT (%) and PLT (x 109/L) in SD rats were respectively 41.7 ±2.9 and 1114 ±173.As anticoagulant ratio was increased ,PT, APTT and TT were extended and FIB was decreased .Compared with the control group ,these PT,APTT,TT,FIB four results of 1∶8 group were not statistically different , of 1∶5 group were statistically different, these PT,APTT,FIB three results of 1∶7 group were not statistically different , TT of 1∶7 group was statistically different.Conclusions The detection of coagulation project coagulation test results were affected by the proportion of anticoagulant and blood .1∶9 was the best anticoagulant ratio in SD rats , 1∶8 can also.Rat had its unique physiological characteristics .The results could provide reference for the evaluation of rats .

  18. Behavioural present value

    OpenAIRE

    Krzysztof Piasecki

    2013-01-01

    Impact of chosen behavioural factors on imprecision of present value is discussed here. The formal model of behavioural present value is offered as a result of this discussion. Behavioural present value is described here by fuzzy set. These considerations were illustrated by means of extensive numerical case study. Finally there are shown that in proposed model the return rate is given, as a fuzzy probabilistic set.

  19. DISPLASIA CUBITAL, PRESENTACIÓN CLÍNICA Y RESULTADOS EN UNA SERIE RETROSPECTIVA DE DIEZ AÑOS A ten year retrospective series of ulnar dysplasia: clinical presentation and treatment results

    Directory of Open Access Journals (Sweden)

    Enrique Vergara-Amador

    2010-01-01

    Full Text Available Antecedentes. La displasia cubital es una alteración en el desarrollo embriológico del lado cubital del antebrazo y la mano. Las deformidades comprometen manos, muñecas y codos; sólo el 11% de los pacientes tienen dedos completos y hasta el 38% de los casos cursan con sindactilias. Objetivo. Describir el perfil epidemiológico y las características clínicas, radiológicas y el tratamiento y los resultados en 14 niños. Material y métodos. Es un estudio descriptivo tipo serie de casos, retrospectivo 14 niños (18 miembros superiores, se evaluaron las características clínicas y radiológicas. Resultados. El compromiso bilateral fue del 28.5 %. Los tipos II y IV de Bayne fueron los predominantes con un 66.5%. Las cirugías múltiples fueron el 41%. Funcionalmente no fue posible homogeneizar un instrumento pre y posoperatorio. El tipo de pinza mejoró de lateral a bidigital o tridigital en el 72.2% de los pacientes, indicador de un progreso funcional significativo. El 84% presentó prensión buena y mejoría en las actividades básicas cotidianas. Conclusión. No existe una clasificación que pueda integrar la diversidad de anomalías. A pesar que la clasificación de Bayne engloba a una gran cantidad de ellos, hay unas difíciles de encasillar como algunos casos con similitud a focomelias y deficiencias transversas del antebrazo. El manejo es específico para cada caso en particular. Sabemos que el compromiso del codo y del primer metacarpiano, son determinantes en el pronóstico funcional. La mejoría de la pinza fue lograda en el 72.2% de los casos llevados a cirugía.Background. The ulnar deficiency is an alteration in the embryological development of the ulnar side of the forearm and the hand. The deformities affect hand, wrist and elbows; only 11% of the patients had complete fingers and 38% of the cases had syndactyly. Objective. Described the epidemiological profile and the clinical and radiological features and the results of

  20. Workshop Presentations: BSCW Analysts

    Data.gov (United States)

    National Aeronautics and Space Administration — These slides were presented at the AePW, April 21-22, 2012. They detail the analytical results generated by each of the participating analysis teams for the...

  1. Workshop Presentations: RSW Analysts

    Data.gov (United States)

    National Aeronautics and Space Administration — These slides were presented at the AePW, April 21-22, 2012. They detail the analytical results generated by each of the participating analysis teams for the...

  2. Workshop Presentations: HIRENASD Analysts

    Data.gov (United States)

    National Aeronautics and Space Administration — These slides were presented at the AePW, April 21-22, 2012. They detail the analytical results generated by each of the participating analysis teams for the HIRENASD.

  3. 结核性脑膜炎临床表现及脑脊液细胞学结果分析%Clinical presentation of tuberculous meningitis and results of cytological determination of the cerebrospinal fluid

    Institute of Scientific and Technical Information of China (English)

    张继萍; 任丽娟; 李永利; 赵亚娟; 叶迎宾; 黄秀香; 邵艳新; 郑立恒

    2015-01-01

    Objective:To investigate the clinical pictures of tuberculous meningitis ( TBM) and significance of cytological determination of the cerebrospi-nal fluid (CSF) for early diagnosis.Methods:The clinical presentations and cytological features of CSF were reviewed in 38 cases of TBM.Results:Thirty-eight cases were primarily sub-acute onset of TBM,and characterized by intracranial hypertension and meningeal irritation.CSF examination showed moder-ate increase of leukocyte count and protein,yet moderate decrease of glucose and chlorine.In early stage of the disease,CSF was presented with mixed cel-lular response to increased leucocytes.The percentage of neutrophil in CSF was slowly decreased slowly ,and this condition maintained for over one month . After regular anti-tuberculosis medication,37 patients were ameliorated and 1 was dead.Therapy started within 2 weeks after onset had better prognosis than delayed intervention.Conclusion:Cytological CSF examination combined with clinical presentation can be favorable differentiation of TMB for cases with lower positive pathogenic findings that makes hard early diagnosis.%目的:探讨结核性脑膜炎的临床表现和脑脊液细胞学检查对结核性脑膜炎及时诊治的指导意义。方法:回顾性分析38例结核性脑膜炎患者的临床病历资料,尤其是细胞学动态变化资料。结果:38例结核性脑膜炎患者多亚急性起病,以颅高压和脑膜刺激征为主要表现,脑脊液白细胞数、蛋白中度升高,葡萄糖、氯化物中度减低,脑脊液细胞学细胞数多中度升高,早期为混合细胞反应,嗜中性粒细胞比例下降较慢,可稳定在1个月以上,正规抗结核治疗后多数好转,发病2周内接受抗结核治疗的患者预后明显优于其他患者。结论:对于病原学检查阳性率低、早期确诊困难的结核性脑膜炎,脑脊液细胞学检查结合临床症状和其他检查对于其鉴别诊断和治疗评估有重要意义。

  4. MEAN PLATELET VOLUME AND RISK OF THROMBOTIC STROKE

    Directory of Open Access Journals (Sweden)

    Prasantha Kumar Thankappan

    2017-07-01

    Full Text Available BACKGROUND Stroke is a major cause of long term morbidity and mortality. Several factors are known to increase the liability to stroke. Platelets play a crucial role in the pathogenesis of atherosclerotic complications, contributing to thrombus formation. Platelet size (mean platelet volume, MPV is a marker and possible determinant of platelet function, large platelets being potentially more reactive. Hence an attempt has-been made to study the association if any between mean platelet volume and thrombotic stroke. The aim of this study was to determine whether an association exists between Mean Platelet Volume (MPV and thrombotic stroke. MATERIALS AND METHODS The study is a case control study and data was collected at Government Medical College Hospital, Kottayam, Kerala a tertiary care referral centre. The study was carried out among fifty patients diagnosed with thrombotic stroke and presenting to the hospital within forty eight hours of onset of symptoms. Fifty age group and sex matched controls were also recruited. Mean platelet volume was obtained using a SYSMEX automated analyser. RESULTS This study has shown a statistically significant relation between mean platelet volume and risk of thrombotic stroke but no statistically significant correlation between clinical severity of stroke and mean platelet volume. CONCLUSION This study has shown an elevation of MPV in acute phase of thrombotic stroke. Platelet mass was found to be more or less a constant. This study did not find a statistically significant correlation between clinical severity of stroke and mean platelet volume.

  5. A STUDY ON MORPHOMETRIC MEASUREMENT OF VOLUME OF ACETABULUM

    Directory of Open Access Journals (Sweden)

    Leena Khobragade,

    2014-09-01

    Full Text Available Background: Hip joint represents an unique functional unit and has complex biomechanical construction. In today’s era where total hip replacement surgeries have made their way it has become imperative for the anatomists to know the variations in acetabular dimensions. Reconstruction of acetabulum in patients with significant acetabular bone deficiency remains a challenge. Hence the present study was carried out with the aim to study the morphometric measurement of volume of acetabulum in both the sexes. Materials and Methods: Material of the study consisted of 110 human hip bones (60 males and 50 females. Volume of Acetabulum (VA was measured on these hip bones on both the sides. Statistical analysis was done using SPSS (Statistical Package for the Social Sciences version 11 and Microsoft Excel 2007. Results: The mean volume of acetabulum in male was 23.13 ml and female was 17.88 ml. The mean volume of acetabulum on right side was 20.55 ml and left side was 20.91 ml. Volume of the acetabulum was greater in males as compared to females and the differences were statistically significant. Volume was greater on the left side as compared to the right side but the difference was statistically non significant. Discussion: Analysing the differences on human acetabulum is helpful in understanding not only morphological but also medicolegal aspects. Conclusion: Volume of the acetabulum was greater in males as compared to females.

  6. FINITE VOLUME METHOD OF MODELLING TRANSIENT GROUNDWATER FLOW

    Directory of Open Access Journals (Sweden)

    N. Muyinda

    2014-01-01

    Full Text Available In the field of computational fluid dynamics, the finite volume method is dominant over other numerical techniques like the finite difference and finite element methods because the underlying physical quantities are conserved at the discrete level. In the present study, the finite volume method is used to solve an isotropic transient groundwater flow model to obtain hydraulic heads and flow through an aquifer. The objective is to discuss the theory of finite volume method and its applications in groundwater flow modelling. To achieve this, an orthogonal grid with quadrilateral control volumes has been used to simulate the model using mixed boundary conditions from Bwaise III, a Kampala Surburb. Results show that flow occurs from regions of high hydraulic head to regions of low hydraulic head until a steady head value is achieved.

  7. Epidural anesthesia, hypotension, and changes in intravascular volume

    DEFF Research Database (Denmark)

    Holte, Kathrine; Foss, Nicolai B; Svensén, Christer

    2004-01-01

    BACKGROUND: The most common side effect of epidural or spinal anesthesia is hypotension with functional hypovolemia prompting fluid infusions or administration of vasopressors. Short-term studies (20 min) in patients undergoing lumbar epidural anesthesia suggest that plasma volume may increase when...... hypotension is present, which may have implications for the choice of treatment of hypotension. However, no long-term information or measurements of plasma volumes with or without hypotension after epidural anesthesia are available. METHODS: In 12 healthy volunteers, the authors assessed plasma (125I...... receiving hydroxyethyl starch. RESULTS: Plasma volume did not change per se after thoracic epidural anesthesia despite a decrease in blood pressure. Plasma volume increased with fluid administration but remained unchanged with vasopressors despite that both treatments had similar hemodynamic effects...

  8. Exploring the connectome: Petascale volume visualization of microscopy data streams

    KAUST Repository

    Beyer, Johanna

    2013-07-01

    Recent advances in high-resolution microscopy let neuroscientists acquire neural-tissue volume data of extremely large sizes. However, the tremendous resolution and the high complexity of neural structures present big challenges to storage, processing, and visualization at interactive rates. A proposed system provides interactive exploration of petascale (petavoxel) volumes resulting from high-throughput electron microscopy data streams. The system can concurrently handle multiple volumes and can support the simultaneous visualization of high-resolution voxel segmentation data. Its visualization-driven design restricts most computations to a small subset of the data. It employs a multiresolution virtual-memory architecture for better scalability than previous approaches and for handling incomplete data. Researchers have employed it for a 1-teravoxel mouse cortex volume, of which several hundred axons and dendrites as well as synapses have been segmented and labeled. © 1981-2012 IEEE.

  9. Volume inside old black holes

    Science.gov (United States)

    Christodoulou, Marios; De Lorenzo, Tommaso

    2016-11-01

    Black holes that have nearly evaporated are often thought of as small objects, due to their tiny exterior area. However, the horizon bounds large spacelike hypersurfaces. A compelling geometric perspective on the evolution of the interior geometry was recently shown to be provided by a generally covariant definition of the volume inside a black hole using maximal surfaces. In this article, we expand on previous results and show that finding the maximal surfaces in an arbitrary spherically symmetric spacetime is equivalent to a 1 +1 geodesic problem. We then study the effect of Hawking radiation on the volume by computing the volume of maximal surfaces inside the apparent horizon of an evaporating black hole as a function of time at infinity: while the area is shrinking, the volume of these surfaces grows monotonically with advanced time, up to when the horizon has reached Planckian dimensions. The physical relevance of these results for the information paradox and the remnant scenarios are discussed.

  10. Revised tephra volumes for Cascade Range volcanoes

    Science.gov (United States)

    Nathenson, Manuel

    2017-07-01

    Isopach maps from tephra eruptions from Mount St. Helens were reported in Carey et al. (1995) and for tephra eruptions from Glacier Peak in Gardner et al. (1998). For exponential thinning, the isopach data only define a single slope on a log thickness versus square root of area plot. Carey et al. (1995) proposed a model that was used to estimate a second slope, and volumes were presented in both studies using this model. A study by Sulpizio (2005) for estimating the second slope and square root of area where the lines intersect involves a systematic analysis of many eruptions to provide correlation equations. The purpose of this paper is to recalculate the volumes of Cascades eruptions and compare results from the two methods. In order to gain some perspective on the methods for estimating the second slope, we use data for thickness versus distance beyond the last isopach that are available for some of the larger eruptions in the Cascades. The thickness versus square root of area method is extended to thickness versus distance by developing an approximate relation between the two assuming elliptical isopachs with the source at one of the foci. Based on the comparisons made between the Carey et al. (1995) and Sulpizio (2005) methods, it is felt that the later method provides a better estimate of the second slope. For Mount St. Helens, the estimates of total volume using the Sulpizio (2005) method are generally smaller than those using the Carey et al. (1995) method. For the volume estimates of Carey et al. (1995), the volume of the May 18, 1980, eruption of Mount St. Helens is smaller than six of the eight previous eruptions. With the new volumes using the Sulpizio (2005) method, the 1980 eruption is smaller in volume than the upper end of the range for only three of the layers (Wn, Ye, and Yn) and is the same size as layer We. Thus the 1980 eruption becomes representative of the mid-range of volumes rather than being in the lower range.

  11. Revised tephra volumes for Cascade Range volcanoes

    Science.gov (United States)

    Nathenson, Manuel

    2017-01-01

    Isopach maps from tephra eruptions from Mount St. Helens were reported in Carey et al. (1995) and for tephra eruptions from Glacier Peak in Gardner et al. (1998). For exponential thinning, the isopach data only define a single slope on a log thickness versus square root of area plot. Carey et al. (1995) proposed a model that was used to estimate a second slope, and volumes were presented in both studies using this model. A study by Sulpizio (2005) for estimating the second slope and square root of area where the lines intersect involves a systematic analysis of many eruptions to provide correlation equations. The purpose of this paper is to recalculate the volumes of Cascades eruptions and compare results from the two methods. In order to gain some perspective on the methods for estimating the second slope, we use data for thickness versus distance beyond the last isopach that are available for some of the larger eruptions in the Cascades. The thickness versus square root of area method is extended to thickness versus distance by developing an approximate relation between the two assuming elliptical isopachs with the source at one of the foci. Based on the comparisons made between the Carey et al. (1995) and Sulpizio (2005) methods, it is felt that the later method provides a better estimate of the second slope. For Mount St. Helens, the estimates of total volume using the Sulpizio (2005) method are generally smaller than those using the Carey et al. (1995) method. For the volume estimates of Carey et al. (1995), the volume of the May 18, 1980, eruption of Mount St. Helens is smaller than six of the eight previous eruptions. With the new volumes using the Sulpizio (2005) method, the 1980 eruption is smaller in volume than the upper end of the range for only three of the layers (Wn, Ye, and Yn) and is the same size as layer We. Thus the 1980 eruption becomes representative of the mid-range of volumes rather than being in the lower range.

  12. A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves

    Directory of Open Access Journals (Sweden)

    Konings Maurits K

    2012-08-01

    Full Text Available Abstract Background In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP is presented, that measures the average stroke volume (SV for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition with six independent electrode pairs distributed over the frontal thoracic skin. In contrast to existing non-invasive electric methods, our method does not use the algorithms of impedance or bioreactance cardiography. Instead, our method is based on specific 2D spatial patterns on the thoracic skin, representing the distribution, over the thorax, of changes in the applied current field caused by cardiac volume changes during the cardiac cycle. Since total heart volume variation during the cardiac cycle is a poor indicator for ventricular stroke volume, our HCP separates atrial filling effects from ventricular filling effects, and retrieves the volume changes of only the ventricles. Methods ex-vivo experiments on a post-mortem human heart have been performed to measure the effects of increasing the blood volume inside the ventricles in isolation, leaving the atrial volume invariant (which can not be done in-vivo. These effects have been measured as a specific 2D pattern of voltage changes on the thoracic skin. Furthermore, a working prototype of the HCP has been developed that uses these ex-vivo results in an algorithm to decompose voltage changes, that were measured in-vivo by the HCP on the thoracic skin of a human volunteer, into an atrial component and a ventricular component, in almost real-time (with a delay of maximally 39 seconds. The HCP prototype has been tested in-vivo on 7 human volunteers, using G-suit inflation and deflation to provoke stroke volume changes, and LVot Doppler as a reference technique. Results The ex-vivo measurements showed that ventricular filling

  13. On pressure: volume relations in hemodialysis

    NARCIS (Netherlands)

    E.H.Y. Ie (Eric)

    2005-01-01

    textabstractChapter 1 is a brief introduction to several aspects of cardiovascular pressure-volume relations in dialysis patients. The aims of the thesis are presented. In Chapter 2, an overview is presented of circulatory physiology in hemodialysis (HD) patients. Volume withdrawal by ultrafiltrati

  14. Multi-Volume High Resolution RGB-D Mapping with Dynamic Volume Placement

    OpenAIRE

    Salvato, Michael; Finman, Ross; Leonard, John

    2015-01-01

    We present a novel RGB-D mapping system for generating 3D maps over spatially extended regions with higher resolution than current methods using multiple, dynamically placed mapping volumes. Our method takes in RGB-D frames and dynamically assigns multiple mapping volumes to the environment, exchanging mapping volumes between the CPU and GPU. Mapping volumes are added or removed as needed to allow for spatially extended, high resolution mapping. Our system is designed to maximize the resoluti...

  15. Communication and presentation skills

    OpenAIRE

    Lorencová, Ivana

    2014-01-01

    This bachelor thesis deals with individual factors of communication and basic presentations skills. The theoretical part specifies the basic elements of verbal and non-verbal communication and basic factors connected with preparation and realisation of a presentation. The practical part of the thesis comprises an analysis of impacts of speaker's visual and other communication influences over an audience. The results are applied to a Multimedia Display exhibition taking place during the bachel...

  16. RESULTS OF AUTOMOBILE BIOGAS ENGINE EXPERIMENTAL INVESTIGATION

    Directory of Open Access Journals (Sweden)

    Abramchuk, F.

    2013-06-01

    Full Text Available The results of experimental study of automotive ICE running using biogas with different volume content of CO2 are presented. Recommendations for choosing the values of air-fuel ratios and ignition timings for different operating modes of the automotive biogas engine depending on fuel chemical composition are given.

  17. High-Volume Transanal Surgery with CPH34 HV for the Treatment of III-IV Degree Haemorrhoids: Final Short-Term Results of an Italian Multicenter Clinical Study

    Directory of Open Access Journals (Sweden)

    Giuliano Reboa

    2016-01-01

    Full Text Available The clinical chart of 621 patients with III-IV haemorrhoids undergoing Stapled Hemorrhoidopexy (SH with CPH34 HV in 2012–2014 was consecutively reviewed to assess its safety and efficacy after at least 12 months of follow-up. Mean volume of prolapsectomy was significantly higher (13.0 mL; SD, 1.4 in larger prolapse (9.3 mL; SD, 1.2 (p<0.001. Residual or recurrent haemorrhoids occurred in 11 of 621 patients (1.8% and in 12 of 581 patients (1.9%, respectively. Relapse was correlated with higher preoperative Constipation Scoring System (CSS (p=0.000, Pescatori’s degree (p=0.000, Goligher’s grade (p=0.003, prolapse exceeding half of the length of the Circular Anal Dilator (CAD (p=0.000, and higher volume of prolapsectomy (p=0.000. At regression analysis, only the preoperative CSS, Pescatori’s degree, Goligher’s grade, and volume of resection were significantly predictive of relapse. A high level of satisfaction (VAS = 8.6; SD, 1.0 coupled with a reduction of 12-month CSS (Δ preoperative CSS/12 mo CSS = 3.4, SD, 2.0; p<0.001 was observed. The wider prolapsectomy achievable with CPH34 HV determined an overall 3.7% relapse rate in patients with high prevalence of large internal rectal prolapse, coupled with high satisfaction index, significant reduction of CSS, and very low complication rates.

  18. High order finite volume methods for singular perturbation problems

    Institute of Scientific and Technical Information of China (English)

    CHEN ZhongYing; HE ChongNan; WU Bin

    2008-01-01

    In this paper we establish a high order finite volume method for the fourth order singular perturbation problems. In conjunction with the optimal meshes, the numerical solutions resulting from the method have optimal convergence order. Numerical experiments are presented to verify our theoretical estimates.

  19. Uranium in US surface, ground, and domestic waters. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Drury, J.S.; Reynolds, S.; Owen, P.T.; Ross, R.H.; Ensminger, J.T.

    1981-04-01

    The report Uranium in US Surface, Ground, and Domestic Waters comprises four volumes. Volumes 2, 3, and 4 contain data characterizing the location, sampling date, type, use, and uranium conentrations of 89,994 individual samples presented in tabular form. The tabular data in volumes 2, 3, and 4 are summarized in volume 1 in narrative form and with maps and histograms.

  20. Verification of aerial photo stand volume tables for southeast Alaska.

    Science.gov (United States)

    Theodore S. Setzer; Bert R. Mead

    1988-01-01

    Aerial photo volume tables are used in the multilevel sampling system of Alaska Forest Inventory and Analysis. These volume tables are presented with a description of the data base and methods used to construct the tables. Volume estimates compiled from the aerial photo stand volume tables and associated ground-measured values are compared and evaluated.

  1. Beyond the Floor Effect on the Wechsler Intelligence Scale for Children-4th Ed. (WISC-IV): Calculating IQ and Indexes of Subjects Presenting a Floored Pattern of Results

    Science.gov (United States)

    Orsini, A.; Pezzuti, L.; Hulbert, S.

    2015-01-01

    Background: It is now widely known that children with severe intellectual disability show a 'floor effect' on the Wechsler scales. This effect emerges because the practice of transforming raw scores into scaled scores eliminates any variability present in participants with low intellectual ability and because intelligence quotient (IQ) scores are…

  2. Site Environmental Report for 2007 Volume I

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, Regina E.; Baskin, David; Fox, Robert; Jelinski, John; Pauer, Ron; Thorson, Patrick; Wahl, Linnea

    2008-09-15

    The Site Environmental Report is an integrated report on Berkeley Lab's environmental programs to satisfy the requirements of DOE Order 231.1A, Environment, Safety, and Health Reporting. It summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2007. Volume I is organized into an executive summary followed by six chapters that contain an overview of the Laboratory, a discussion of the Laboratory's environmental management system, the status of environmental programs, and summarized results from surveillance and monitoring activities.

  3. Ovarian volume throughout life

    DEFF Research Database (Denmark)

    Kelsey, Thomas W; Dodwell, Sarah K; Wilkinson, A Graham

    2013-01-01

    cancer. To date there is no normative model of ovarian volume throughout life. By searching the published literature for ovarian volume in healthy females, and using our own data from multiple sources (combined n=59,994) we have generated and robustly validated the first model of ovarian volume from...... to about 2.8 mL (95% CI 2.7-2.9 mL) at the menopause and smaller volumes thereafter. Our model allows us to generate normal values and ranges for ovarian volume throughout life. This is the first validated normative model of ovarian volume from conception to old age; it will be of use in the diagnosis...

  4. TRU Waste Sampling Program: Volume I. Waste characterization

    Energy Technology Data Exchange (ETDEWEB)

    Clements, T.L. Jr.; Kudera, D.E.

    1985-09-01

    Volume I of the TRU Waste Sampling Program report presents the waste characterization information obtained from sampling and characterizing various aged transuranic waste retrieved from storage at the Idaho National Engineering Laboratory and the Los Alamos National Laboratory. The data contained in this report include the results of gas sampling and gas generation, radiographic examinations, waste visual examination results, and waste compliance with the Waste Isolation Pilot Plant-Waste Acceptance Criteria (WIPP-WAC). A separate report, Volume II, contains data from the gas generation studies.

  5. RELAP5/MOD3 code manual. Volume 4, Models and correlations

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    The RELAP5 code has been developed for best-estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents and operational transients such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. RELAP5/MOD3 code documentation is divided into seven volumes: Volume I presents modeling theory and associated numerical schemes; Volume II details instructions for code application and input data preparation; Volume III presents the results of developmental assessment cases that demonstrate and verify the models used in the code; Volume IV discusses in detail RELAP5 models and correlations; Volume V presents guidelines that have evolved over the past several years through the use of the RELAP5 code; Volume VI discusses the numerical scheme used in RELAP5; and Volume VII presents a collection of independent assessment calculations.

  6. Does Stroke Volume Increase During an Incremental Exercise? A Systematic Review

    Science.gov (United States)

    Vieira, Stella S.; Lemes, Brunno; de T. C. de Carvalho, Paulo; N. de Lima, Rafael; S. Bocalini, Danilo; A. S. Junior, José; Arsa, Gisela; A. Casarin, Cezar; L. Andrade, Erinaldo; J. Serra, Andrey

    2016-01-01

    Introduction: Cardiac output increases during incremental-load exercise to meet metabolic skeletal muscle demand. This response requires a fast adjustment in heart rate and stroke volume. The heart rate is well known to increase linearly with exercise load; however, data for stroke volume during incremental-load exercise are unclear. Our objectives were to (a) review studies that have investigated stroke volume on incremental load exercise and (b) summarize the findings for stroke volume, primarily at maximal-exercise load. Methods: A comprehensive review of the Cochrane Library’s, Embase, Medline, SportDiscus, PubMed, and Web of Sci-ence databases was carried out for the years 1985 to the present. The search was performed between February and June 2014 to find studies evaluating changes in stroke volume during incremental-load exercise. Controlled and uncontrolled trials were evaluated for a quality score. Results: The stroke volume data in maximal-exercise load are inconsistent. There is evidence to hypothesis that stroke volume increases during maximal-exercise load, but other lines of evidence indicate that stroke volume reaches a plateau under these circumstances, or even decreases. Conclusion: The stroke volume are unclear, include contradictory evidence. Additional studies with standardized reporting for subjects (e.g., age, gender, physical fitness, and body position), exercise test protocols, and left ventricular function are required to clarify the characteristics of stroke volume during incremental maximal-exercise load. PMID:27347221

  7. Bare-Hand Volume Cracker for Raw Volume Data Analysis

    Directory of Open Access Journals (Sweden)

    Bireswar Laha

    2016-09-01

    Full Text Available Analysis of raw volume data generated from different scanning technologies faces a variety of challenges, related to search, pattern recognition, spatial understanding, quantitative estimation, and shape description. In a previous study, we found that the Volume Cracker (VC 3D interaction (3DI technique mitigated some of these problems, but this result was from a tethered glove-based system with users analyzing simulated data. Here, we redesigned the VC by using untethered bare-hand interaction with real volume datasets, with a broader aim of adoption of this technique in research labs. We developed symmetric and asymmetric interfaces for the Bare-Hand Volume Cracker (BHVC through design iterations with a biomechanics scientist. We evaluated our asymmetric BHVC technique against standard 2D and widely used 3D interaction techniques with experts analyzing scanned beetle datasets. We found that our BHVC design significantly outperformed the other two techniques. This study contributes a practical 3DI design for scientists, documents lessons learned while redesigning for bare-hand trackers, and provides evidence suggesting that 3D interaction could improve volume data analysis for a variety of visual analysis tasks. Our contribution is in the realm of 3D user interfaces tightly integrated with visualization, for improving the effectiveness of visual analysis of volume datasets. Based on our experience, we also provide some insights into hardware-agnostic principles for design of effective interaction techniques.

  8. Combining ordinary and topological finite volume effects for fixed topology simulations

    CERN Document Server

    Dromard, Arthur; Gerber, Urs; Mejía-Díaz, Héctor; Wagner, Marc

    2015-01-01

    In lattice quantum field theories with topological sectors, simulations at fine lattice spacings --- with typical algorithms --- tend to freeze topologically. In such cases, specific topological finite size effects have to be taken into account to obtain physical results, which correspond to infinite volume or unfixed topology. Moreover, when a theory like QCD is simulated in a moderate volume, one also has to overcome ordinary finite volume effects (not related to topology freezing). To extract physical results from simulations affected by both types of finite volume effects, we extend a known relation between hadron masses at fixed and unfixed topology by additionally incorporating ordinary finite volume effects. We present numerical results for SU(2) Yang-Mills theory.

  9. Site Environmental Report for 2011, Volumes 1& 2

    Energy Technology Data Exchange (ETDEWEB)

    Baskin, David; Bauters, Tim; Borglin, Ned; Fox, Robert; Horst, Blair; Jelinski, John; Lackner, Ginny; Philliber, Jeff; Rothermich, Nancy; Thorson, Patrick; Wahl, Linnea; Xu, Suying

    2012-09-12

    The Site Environmental Report for 2011 summarizes Berkeley Lab’s environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year (CY) 2011. Throughout this report, “Berkeley Lab” or “LBNL” refers both to (1) the multiprogram scientific facility the UC manages and operates on the 202-acre university-owned site located in the hills above the UC Berkeley campus, and the site itself, and (2) the UC as managing and operating contractor for Ernest Orlando Lawrence Berkeley National Laboratory. The report is separated into two volumes. Volume I is organized into an executive summary followed by six chapters that include an overview of LBNL, a discussion of its Environmental Management System (EMS), the status of environmental programs, summarized results from surveillance and monitoring activities, and quality assurance (QA) measures. Volume II contains individual data results from surveillance and monitoring activities.

  10. Mean nuclear volume

    DEFF Research Database (Denmark)

    Mogensen, O.; Sørensen, Flemming Brandt; Bichel, P.

    1999-01-01

    We evaluated the following nine parameters with respect to their prognostic value in females with endometrial cancer: four stereologic parameters [mean nuclear volume (MNV), nuclear volume fraction, nuclear index and mitotic index], the immunohistochemical expression of cancer antigen (CA125...

  11. Fiscal 1997 report on the results of the research on the development of high-performance industrial furnaces. Volume 3; 1997 nendo seika hokokusho (koseino kogyoro no kaihatsu ni kansuru kenkyu seika hokokusto)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    A R and D was conducted for the purpose of developing remarkable energy conservation/CO2 reduction technologies. In fiscal 1997, the five working groups about the following were formed to have animated discussions: the basic research, heating furnace, heat treatment furnace, melting furnace, and tubular heating furnace. The research subjects are the pursuit/deepening of the base study on flame structures in high temperature air combustion, critical heat recovery of the system in high temperature air combustion, examination of the basic common technology on the ultimate optimization of the material heat transfer, construction of general-purpose experimental database, setting-up of design standards for general-purpose high-performance industrial furnaces, presentation of examples of the actual trial design based on the design standards and feasibility study of the practical application, preparatory support of the field test project on high-performance industrial furnaces for commercialization/diffusion/spread, etc. Further, how to arrange the developmental results was studied to make the results of the project useful for study of the prompt commercialization. 442 refs., 1444 figs., 311 tabs.

  12. Fiscal 1997 report on the results of the research on the development of high-performance industrial furnaces. Volume 2; 1997 nendo seika hokokusho (koseino kogyoro no kaihatsu ni kansuru kenkyu seika hokokusto)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    A R and D was conducted for the purpose of developing remarkable energy conservation/CO2 reduction technologies. In fiscal 1997, the five working groups about the following were formed to have animated discussions: the basic research, heating furnace, heat treatment furnace, melting furnace, and tubular heating furnace. The research subjects are the pursuit/deepening of the base study on flame structures in high temperature air combustion, critical heat recovery of the system in high temperature air combustion, examination of the basic common technology on the ultimate optimization of the material heat transfer, construction of general-purpose experimental database, setting-up of design standards for general-purpose high-performance industrial furnaces, presentation of examples of the actual trial design based on the design standards and feasibility study of the practical application, preparatory support of the field test project on high-performance industrial furnaces for commercialization/diffusion/spread, etc. Further, how to arrange the developmental results was studied to make the results of the project useful for study of the prompt commercialization. 442 refs., 1444 figs., 311 tabs

  13. Micro analysis of fringe field formed inside LDA measuring volume

    Science.gov (United States)

    Ghosh, Abhijit; Nirala, A. K.

    2016-05-01

    In the present study we propose a technique for micro analysis of fringe field formed inside laser Doppler anemometry (LDA) measuring volume. Detailed knowledge of the fringe field obtained by this technique allows beam quality, alignment and fringe uniformity to be evaluated with greater precision and may be helpful for selection of an appropriate optical element for LDA system operation. A complete characterization of fringes formed at the measurement volume using conventional, as well as holographic optical elements, is presented. Results indicate the qualitative, as well as quantitative, improvement of fringes formed at the measurement volume by holographic optical elements. Hence, use of holographic optical elements in LDA systems may be advantageous for improving accuracy in the measurement.

  14. Octree-based Volume Sculpting

    DEFF Research Database (Denmark)

    Bærentzen, Jakob Andreas

    1998-01-01

    A volume sculpting system is presented. The system provides tools for interactive editing of a voxel raster that is stored in an octree data structure. Two different modes of sculpting are supported: Sculpting by adding and subtracting solids, and sculpting with tools that are based on a spray ca...... metaphor. The possibility of extending the method to support multiresolution sculpting is discussed....

  15. Editorial, Volume 5, Issue 1

    Directory of Open Access Journals (Sweden)

    Kristy L. Archuleta

    2014-08-01

    Full Text Available Welcome to Volume 5, Issue 1 of the Journal of Financial Therapy! In this issue, four scholarly papers are presented along with two profiles and a book review. These four papers address very important issues, such as mental health therapists’ competency in working with financial issues, financial stress of college students, parental messages about money, and financial advice media.

  16. Abstract Presentations: What Do SGIM Presenters Prefer?

    OpenAIRE

    Tulsky, Asher A.; Kouides, Ruth W

    1998-01-01

    We surveyed physicians presenting abstracts at the 1995 Society of General Internal Medicine annual meeting to determine whether the oral or poster format better achieved their presentation goals. Poster presentations better met respondents' objectives for feedback and criticism and for networking and developing collaborative projects, while oral presentations better met their objectives for national visibility and sharing knowledge within one's field. Sixty-nine percent of respondents prefer...

  17. Human Health and Ecological Risk Assessment for the Operation of the Explosives Waste Treatment Facility at Site 300 of the Lawrence Livermore National Laboratory Volume 1: Report of Results

    Energy Technology Data Exchange (ETDEWEB)

    Gallegos, G; Daniels, J; Wegrecki, A

    2006-04-24

    This document contains the human health and ecological risk assessment for the Resource Recovery and Conservation Act (RCRA) permit renewal for the Explosives Waste Treatment Facility (EWTF). Volume 1 is the text of the risk assessment, and Volume 2 (provided on a compact disc) is the supporting modeling data. The EWTF is operated by the Lawrence Livermore National Laboratory (LLNL) at Site 300, which is located in the foothills between the cities of Livermore and Tracy, approximately 17 miles east of Livermore and 8 miles southwest of Tracy. Figure 1 is a map of the San Francisco Bay Area, showing the location of Site 300 and other points of reference. One of the principal activities of Site 300 is to test what are known as ''high explosives'' for nuclear weapons. These are the highly energetic materials that provide the force to drive fissionable material to criticality. LLNL scientists develop and test the explosives and the integrated non-nuclear components in support of the United States nuclear stockpile stewardship program as well as in support of conventional weapons and the aircraft, mining, oil exploration, and construction industries. Many Site 300 facilities are used in support of high explosives research. Some facilities are used in the chemical formulation of explosives; others are locations where explosive charges are mechanically pressed; others are locations where the materials are inspected radiographically for such defects as cracks and voids. Finally, some facilities are locations where the machined charges are assembled before they are sent to the on-site test firing facilities, and additional facilities are locations where materials are stored. Wastes generated from high-explosives research are treated by open burning (OB) and open detonation (OD). OB and OD treatments are necessary because they are the safest methods for treating explosives wastes generated at these facilities, and they eliminate the requirement for

  18. Report on the explosion, fire, and oil spill resulting in one fatality and injury on September 21, 1978, at Well 6 of Cavern 6 at the West Hackberry, Louisiana, oil storage site of the strategic petroleum reserve. Volume I

    Energy Technology Data Exchange (ETDEWEB)

    1978-11-01

    The following report is the independent product of the Accident Investigation Committee which was commissioned by the Department of Energy following the accident on September 21, 1978, at the Strategic Petroleum Reserve site at West Hackberry, Louisiana. This Committee is charged with the task of determining the nature, extent, and causes of that accident, which resulted in loss of life, injury and property damage, and the need for corrective action. A nonburning oil spill went into nearby Black Lake, but was contained by the deployment of a series of oil spill containment booms and a prevailing wind from the northeast that kept the oil spill in a restricted area near shore. Because of the rapid and effective containment and cleanup of the oil spill by the Rapid Response Team, it appears very likely at this time that Black Lake will not sustain any permanent environmental damage. Cavern 6 initially contained approximately 7,000,000 barrels of oil at a pressure of 650 psig measured at the well head. As of September 29, 1978, the Strategic Petroleum Reserve Office - New Orleans (SPRO) estimated that oil expulsion from Cavern 6 was 67,510 barrels. Of this, 34,620 barrels of oil are accounted for, including 31,200 barrels of oil released into Black Lake and subsequently recovered. The remainder (32,890 barrels) was assumed by SPRO to have been burned. The total loss is presently estimated by the Accident Investigation Committee 's consultant to be $12 million. An assessment of the technical problems present at the time of the accident is given. Recommendations for improved safety procedures are included.

  19. Primary progressive aphasia patients evaluated using diffusion tensor imaging and voxel based volumetry-preliminary results

    Directory of Open Access Journals (Sweden)

    Fábio Pascotto de Oliveira

    2011-06-01

    Full Text Available There are individuals who have a progressive language deficit without presenting cognitive deficits in other areas. One of the diseases related to this presentation is primary progressive aphasia (PPA. OBJECTIVE: Identify by means of diffusion tensor imaging (DTI and measurements of cortical volume, brain areas that lead to dysphasia when presenting signs of impaired connectivity or reduced volume. METHOD: Four patients with PPA were evaluated using DTI, and measurements of cortical volumes in temporal areas. These patients were compared with two normal volunteers. RESULTS: There is a trend to a difference in the number and volume of related fibers between control group and patients with PPA. Comparing cortical volumes in temporal areas between groups yielded a trend to a smaller volume in PPA patients. CONCLUSION: Patients with PPA have a trend to impairment in cortical and subcortical levels regarding relevant areas.

  20. Curve-centric volume reformation for comparative visualization.

    Science.gov (United States)

    Daae Lampe, Ove; Correa, Carlos; Ma, Kwan-Liu; Hauser, Helwig

    2009-01-01

    We present two visualization techniques for curve-centric volume reformation with the aim to create compelling comparative visualizations. A curve-centric volume reformation deforms a volume, with regards to a curve in space, to create a new space in which the curve evaluates to zero in two dimensions and spans its arc-length in the third. The volume surrounding the curve is deformed such that spatial neighborhood to the curve is preserved. The result of the curve-centric reformation produces images where one axis is aligned to arc-length, and thus allows researchers and practitioners to apply their arc-length parameterized data visualizations in parallel for comparison. Furthermore we show that when visualizing dense data, our technique provides an inside out projection, from the curve and out into the volume, which allows for inspection what is around the curve. Finally we demonstrate the usefulness of our techniques in the context of two application cases. We show that existing data visualizations of arc-length parameterized data can be enhanced by using our techniques, in addition to creating a new view and perspective on volumetric data around curves. Additionally we show how volumetric data can be brought into plotting environments that allow precise readouts. In the first case we inspect streamlines in a flow field around a car, and in the second we inspect seismic volumes and well logs from drilling.

  1. 3D photography is a reliable method of measuring infantile haemangioma volume over time.

    Science.gov (United States)

    Robertson, Sarah A; Kimble, Roy M; Storey, Kristen J; Gee Kee, Emma L; Stockton, Kellie A

    2016-09-01

    Infantile haemangiomas are common lesions of infancy. With the development of novel treatments utilised to accelerate their regression, there is a need for a method of assessing these lesions over time. Volume is an ideal assessment method because of its quantifiable nature. This study investigated whether 3D photography is a valid tool for measuring the volume of infantile haemangiomas over time. Thirteen children with infantile haemangiomas presenting to the Vascular Anomalies Clinic, Royal Children's Hospital/Lady Cilento Children's Hospital treated with propranolol were included in the study. Lesion volume was assessed using 3D photography at presentation, one month and three months follow up. Intrarater reliability was determined by retracing all images several months after the initial mapping. Interrater reliability of the 3D camera software was determined by two investigators, blinded to each other's results, independently assessing infantile haemangioma volume. Lesion volume decreased significantly between presentation and three-month follow-up (p<0.001). Volume intra- and interrater reliability were excellent with ICC 0.991 (95% CI 0.982, 0.995) and 0.978 (95% CI 0.955, 0.989), respectively. This study demonstrates images taken with the 3D LifeViz™ camera and lesion volume calculated with Dermapix® software is a reliable method for assessing infantile haemangioma volume over time. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Large volume cryogenic silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Braggio, C. [Dipartimento di Fisica, Universita di Padova, via Marzolo 8, 35131 Padova (Italy); Boscardin, M. [Fondazione Bruno Kessler (FBK), via Sommarive 18, I-38100 Povo (Italy); Bressi, G. [INFN sez. di Pavia, via Bassi 6, 27100 Pavia (Italy); Carugno, G.; Corti, D. [INFN sez. di Padova, via Marzolo 8, 35131 Padova (Italy); Galeazzi, G. [INFN lab. naz. Legnaro, viale dell' Universita 2, 35020 Legnaro (Italy); Zorzi, N. [Fondazione Bruno Kessler (FBK), via Sommarive 18, I-38100 Povo (Italy)

    2009-12-15

    We present preliminary measurements for the development of a large volume silicon detector to detect low energy and low rate energy depositions. The tested detector is a one cm-thick silicon PIN diode with an active volume of 31 cm{sup 3}, cooled to the liquid helium temperature to obtain depletion from thermally-generated free carriers. A thorough study has been done to show that effects of charge trapping during drift disappears at a bias field value of the order of 100V/cm.

  3. Recent results from ANTARES

    Directory of Open Access Journals (Sweden)

    Trovato Agata

    2015-01-01

    Full Text Available Operating 40 km off the coast of France since 2007, the ANTARES detector is the largest deep-sea neutrino telescope in the Northern Hemisphere with an instrumented volume of more than 0.01 cubic kilometers. It consists of an array of 885 photomultipliers detecting the Cherenkov light induced by charged leptons produced by neutrino interactions in and around the detector. The primary goal of ANTARES is to search for astrophysical neutrinos in the TeV–PeV range. This comprises generic searches for any diffuse cosmic neutrino flux as well as more specific searches for astrophysical galactic and extragalactic sources. The search program also includes multi-messenger analyses based on time and/or space coincidences with other cosmic probes. The ANTARES observatory is sensitive to a wide-range of other phenomena, from atmospheric neutrino oscillations to dark matter annihilation. In this contribution, recent results from the ANTARES neutrino telescope will be presented.

  4. Locally advanced breast cancers are more likely to present as Interval Cancers: results from the I-SPY 1 TRIAL (CALGB 150007/150012, ACRIN 6657, InterSPORE Trial).

    Science.gov (United States)

    Lin, Cheryl; Buxton, Meredith Becker; Moore, Dan; Krontiras, Helen; Carey, Lisa; DeMichele, Angela; Montgomery, Leslie; Tripathy, Debasish; Lehman, Constance; Liu, Minetta; Olapade, Olufunmilayo; Yau, Christina; Berry, Donald; Esserman, Laura J

    2012-04-01

    Interval cancers (ICs), defined as cancers detected between regular screening mammograms, have been shown to be of higher grade, larger size, and associated with lower survival, compared with screen-detected cancers (SDCs) and comprise 17% of cancers from population-based screening programs. We sought to determine the frequency of ICs in a study of locally advanced breast cancers, the I-SPY 1 TRIAL. Screening was defined as having a mammogram with 2 years, and the proportion of ICs at 1 and 2 years was calculated for screened patients. Differences in clinical characteristics for ICs versus SDCs and screened versus non-screened cancers were assessed. For the 219 evaluable women, mean tumor size was 6.8 cm. Overall, 80% of women were over 40 and eligible for screening; however, only 31% were getting screened. Among women screened, 85% were ICs, with 68% diagnosed within 1 year of a previously normal mammogram. ICs were of higher grade (49% vs. 10%) than SDCs. Among non-screened women, 28% (43/152) were younger than the recommended screening age of 40. Of the entire cohort, 12% of cancers were mammographically occult (MO); the frequency of MO cancers did not differ between screened (11%) and non-screened (15%). ICs were common in the I-SPY 1 TRIAL suggesting the potential need for new approaches beyond traditional screening to reduce mortality in women who present with larger palpable cancers.

  5. Evaluating Volume Fractions of the Elements for Composite Laminates by Using Dielectric Properties

    Institute of Scientific and Technical Information of China (English)

    周胜; 储才元; 严灏景

    2001-01-01

    A series and parallel model for investigating the capacity of composite laminates and the relationship between the dielectric properties of the composites and its constituents are presented. Volume fractions of the constituents are considered in this study. The expression of the complex dielectric constants for evaluating volume fractions under discrete frequencies is established and the general solutions for the resultant linear simultaneous equations for system are also exploited.The results show that the high accuracy of proposed method is obtained.

  6. Treatment with autologous antigen-presenting cells activated with the HER-2 based antigen Lapuleucel-T: results of a phase I study in immunologic and clinical activity in HER-2 overexpressing breast cancer.

    Science.gov (United States)

    Park, John W; Melisko, Michelle E; Esserman, Laura J; Jones, Lori A; Wollan, Jami Breen; Sims, Robert

    2007-08-20

    Lapuleucel-T (APC8024), an autologous active cellular immunotherapy, was prepared from peripheral-blood mononuclear cells, including antigen-presenting cells, that were activated in vitro with recombinant fusion protein BA7072. This antigen construct consisted of sequences from intracellular and extracellular domains of human epidermal growth factor receptor 2 (HER-2) linked to granulocyte-macrophage colony-stimulating factor. We conducted a phase I study to evaluate the safety and immunologic activity of lapuleucel-T in patients with HER-2-overexpressing metastatic breast cancer. Metastatic breast cancer patients whose tumors overexpressed or amplified HER-2 were eligible. Patients underwent leukapheresis and subsequent lapuleucel-T infusion 2 days later at weeks 0, 2, and 4. Patients who achieved a partial response (PR) or had stable disease (SD) lasting through week 48 were eligible for re-treatment using the same protocol and dose as their initial treatment. End points included safety, immunologic activity, and antitumor activity. Nineteen patients were enrolled; 18 patients received treatment. Therapy was well tolerated, with no grade 3 or 4 adverse events associated with the treatment. Significant cellular immune responses specific for the immunizing antigen and HER-2 sequences were induced after treatment, as measured by lymphocyte proliferation and interferon gamma enzyme-linked immunospot assay. One patient experienced a PR lasting 6 months. Three additional patients had SD lasting more than 1 year. Autologous active cellular immunotherapy with lapuleucel-T was feasible, safe, and well tolerated. The treatment stimulated significant immune responses, which were enhanced after boost infusions. Lapuleucel-T therapy was associated with tumor response or extended disease stabilization in some patients and warrants further investigation.

  7. Extracting three-body observables from finite-volume quantities

    CERN Document Server

    Hansen, Maxwell T

    2015-01-01

    Scattering and transition amplitudes with three-hadron final states play an important role in nuclear and particle physics. However, predicting such quantities using numerical Lattice QCD is very difficult, in part because of the effects of Euclidean time and finite volume. In this review we highlight recent formal developments that work towards overcoming these issues. We organize the presentation into three parts: large volume expansions, non-relativistic nonperturbative analyses, and nonperturbative studies based in relativistic field theory. In the first part we discuss results for ground state energies and matrix elements given by expanding in inverse box length, $1/L$. We describe complications that arise at $\\mathcal O(1/L^6)$ and include a table summarizing the results of different calculations. In the second part we summarize three recent non-relativistic non-perturbative studies and highlight the main conclusions of these works. This includes demonstrating that the three-particle finite-volume spect...

  8. LOFT reflood as a function of accumulator initial gas volume

    Energy Technology Data Exchange (ETDEWEB)

    Rhodes, H.F.

    1978-06-01

    The effect of the initial gas volume in the LOFT accumulators on the time to start of core reflood, after a LOCA, has been studied. The bases of the calculations are the data used and results presented in the Safety Analysis Report, Rev.1, August 1977, and the data in the RELAP and TOODEE2 program input and output listings. The results of this study show that an initial nitrogen volume of 12 cu ft, or more (at 600 psig initial pressure), would cause start of core reflood in time to prevent the cladding temperature from reaching 2200/sup 0/F. The 12 cu ft initial volume will expand from 600 psig, initial pressure, to about 10 psig (containment pressure shortly after start of LOCA is approximately 8 psig) when all ECC liquid has been expelled from the accumulator. This pressure margin is considered too small; the ECC flowrate will be zero before the accumulator is empty.

  9. Presentation rubric: improving faculty professional presentations.

    Science.gov (United States)

    Hayne, Arlene N; McDaniel, Gretchen S

    2013-01-01

    This article describes the content of a presentation evaluation rubric for use in the development and improvement in faculty performance to enhance learning. Lectures or professional presentations require skills that can be learned through the use of evidence-based practices for all forms of public speaking. A core competency of nursing faculty is to serve as a role model in skilled oral communication. The use of an evaluation presentation rubric can increase faculty competency in this area. © 2013 Wiley Periodicals, Inc.

  10. Thermodynamic volume of cosmological solitons

    Science.gov (United States)

    Mbarek, Saoussen; Mann, Robert B.

    2017-02-01

    We present explicit expressions of the thermodynamic volume inside and outside the cosmological horizon of Eguchi-Hanson solitons in general odd dimensions. These quantities are calculable and well-defined regardless of whether or not the regularity condition for the soliton is imposed. For the inner case, we show that the reverse isoperimetric inequality is not satisfied for general values of the soliton parameter a, though a narrow range exists for which the inequality does hold. For the outer case, we find that the mass Mout satisfies the maximal mass conjecture and the volume is positive. We also show that, by requiring Mout to yield the mass of dS spacetime when the soliton parameter vanishes, the associated cosmological volume is always positive.

  11. Age estimation from canine volumes.

    Science.gov (United States)

    De Angelis, Danilo; Gaudio, Daniel; Guercini, Nicola; Cipriani, Filippo; Gibelli, Daniele; Caputi, Sergio; Cattaneo, Cristina

    2015-08-01

    Techniques for estimation of biological age are constantly evolving and are finding daily application in the forensic radiology field in cases concerning the estimation of the chronological age of a corpse in order to reconstruct the biological profile, or of a living subject, for example in cases of immigration of people without identity papers from a civil registry. The deposition of teeth secondary dentine and consequent decrease of pulp chamber in size are well known as aging phenomena, and they have been applied to the forensic context by the development of age estimation procedures, such as Kvaal-Solheim and Cameriere methods. The present study takes into consideration canines pulp chamber volume related to the entire teeth volume, with the aim of proposing new regression formulae for age estimation using 91 cone beam computerized scans and a freeware open-source software, in order to permit affordable reproducibility of volumes calculation.

  12. Thermodynamic Volume of Cosmological Solitons

    CERN Document Server

    Mbarek, Saoussen

    2016-01-01

    We present explicit expressions of the thermodynamic volume inside and outside the cosmological horizon of Eguchi-Hanson solitons in general odd dimensions. These quantities are calculable and well-defined regardless of whether or not the regularity condition for the soliton is imposed. For the inner case, we show that the reverse isoperimetric inequality is not satisfied for general values of the soliton parameter $a$, though a narrow range exists for which the inequality does hold. For the outer case, we find that the mass $M_{out}$ satisfies the maximal mass conjecture and the volume is positive. We also show that, by requiring $M_{out}$ to yield the mass of dS spacetime when the soliton parameter vanishes, the associated cosmological volume is always positive.

  13. Dictionary Based Segmentation in Volumes

    DEFF Research Database (Denmark)

    Emerson, Monica Jane; Jespersen, Kristine Munk; Jørgensen, Peter Stanley

    2015-01-01

    We present a method for supervised volumetric segmentation based on a dictionary of small cubes composed of pairs of intensity and label cubes. Intensity cubes are small image volumes where each voxel contains an image intensity. Label cubes are volumes with voxelwise probabilities for a given...... label. The segmentation process is done by matching a cube from the volume, of the same size as the dictionary intensity cubes, to the most similar intensity dictionary cube, and from the associated label cube we get voxel-wise label probabilities. Probabilities from overlapping cubes are averaged...... and hereby we obtain a robust label probability encoding. The dictionary is computed from labeled volumetric image data based on weighted clustering. We experimentally demonstrate our method using two data sets from material science – a phantom data set of a solid oxide fuel cell simulation for detecting...

  14. Prognostic value of clinical variables at presentation in patients with non-ST-segment elevation acute coronary syndromes: results of the Proyecto de Estudio del Pronóstico de la Angina (PEPA).

    Science.gov (United States)

    López de Sá, Esteban; López-Sendón, José; Anguera, Ignasi; Bethencourt, Armando; Bosch, Xavier

    2002-11-01

    Patients with suspected non-ST-segment elevation acute coronary syndromes (NSTEACS) constitute a heterogeneous population with variable outcomes. Risk stratification in this population of patients is difficult due to the complexity in patient risk profile. We conducted this study to characterize the value of clinical and electrocardiographic variables for risk stratification in an unselected population of consecutive patients with NSTEACS on admission. Thirty-five clinical and electrocardiographic variables at presentation in the emergency room of 18 hospitals were prospectively analyzed in 4,115 patients with NSTEACS and related with the outcomes at 90 days. We also developed a risk score using the variables found to be independent predictors of ischemic events to facilitate risk stratification. Cardiovascular mortality was 4.3% and the rate for the outcome of either cardiovascular death or nonfatal myocardial infarction was 6.9%. The only independent predictors of mortality were age, diabetes, peripheral vascular disease, postinfarction angina, Killip class > or = 2, ST-segment depression, and elevation of cardiac markers. A risk profile using the variables found to be independent predictors of events was calculated for cardiovascular mortality and for the combination of either death or nonfatal myocardial infarction. Event rates increased significantly in all subgroups of patients based on the number of independent risk factors as the risk score increased. Using these factors, 90-day mortality ranged from as low as 0.4% in patients with no risk factors to 21.1% for those with more than 4 risk factors. In conclusion, simple clinical and electrocardiographic data obtained at hospital admission allow an accurate risk stratification of patients with NSTEACS. In the PEPA registry, simple variables easy to obtain at admission appear to be a valuable tool in discerning between patients at very low and very high risk according to the cluster of factors for each patient

  15. Control volume based hydrocephalus research

    Science.gov (United States)

    Cohen, Benjamin; Voorhees, Abram; Wei, Timothy

    2008-11-01

    Hydrocephalus is a disease involving excess amounts of cerebral spinal fluid (CSF) in the brain. Recent research has shown correlations to pulsatility of blood flow through the brain. However, the problem to date has presented as too complex for much more than statistical analysis and understanding. This talk will highlight progress on developing a fundamental control volume approach to studying hydrocephalus. The specific goals are to select physiologically control volume(s), develop conservation equations along with the experimental capabilities to accurately quantify terms in those equations. To this end, an in vitro phantom is used as a simplified model of the human brain. The phantom's design consists of a rigid container filled with a compressible gel. The gel has a hollow spherical cavity representing a ventricle and a cylindrical passage representing the aquaducts. A computer controlled piston pump supplies pulsatile volume fluctuations into and out of the flow phantom. MRI is used to measure fluid velocity, and volume change as functions of time. Independent pressure measurements and flow rate measurements are used to calibrate the MRI data. These data are used as a framework for future work with live patients.

  16. ISABELLE. Volume 4. Detector R and D

    Energy Technology Data Exchange (ETDEWEB)

    1981-01-01

    Workshop participants were asked to assess the current status of detector R and D in terms of the specific needs for ISABELLE experiments: the demands of high particle rates, extremely selective triggers on complex and rare events, and the economics of large detector systems. The detailed results of working groups convened to consider specific areas of detector development are presented. The key points of this assessment, as regards the continuing R and D program for ISABELLE are summarized here. Twenty-six items from the volume were prepared separately for the data base, along with five items previously prepared. (GHT)

  17. Present-day thermal signatures of different heat transport mechanisms within the Northeast German basin and their sensitivity to the resolution of the computational mesh - results from coupled 3D numerical simulations

    Science.gov (United States)

    Kaiser, B. O.; Scheck-Wenderoth, M.; Cacace, M.; Przybycin, A.; Lewerenz, B.

    2012-04-01

    Sedimentary basins provide a significant portion of geothermal energy. Making geothermal heat an effective source for sustainable energy supply requires a quantitative reserve assessment. Numerical (mathematical) models of sedimentary basins are useful tools for first-order approximations of the geothermal potential on a regional scale. The challenge for numerical investigations within complex geological sedimentary basins is that the thermal field contains superposed signals originating from several heat transport processes, different in nature but physically coupled. An additional difficulty arising from numerical simulations is the error introduced by discretizing a continuous physical system into its numerical counterpart. Different mesh resolutions may lead to different and sometimes contrasting computational findings, thus making the reliability of coupled numerical simulations at least questionable. By means of 3D numerical simulations we discriminate conductive, forced convective and free thermal convective heat transport within a complex geological setting, the Northeast German Basin. As a second step we explore the sensitivity of each heat transport process with regard to the spatial discretization. The internal geological structure of the NEGB is characterized by the presence of a highly structured Zechstein salt sequence piercing the sedimentary overburden locally. Moreover, the Zechstein salt is impervious to fluid flow and has a relative high thermal conductivity compared to the surrounding clastic sediments. Computational results show that these hydrogeological conditions exerts primary constraints on the internal hydrothermal setting of the basin. The impervious nature of the Zechstein salt inhibits groundwater flow to be effective. Accordingly, conduction is the main heat transport mechanism within the salt. In contrast, forced convective heat transport triggerd by topographic gradients affects mainly the temperature distribution within the post

  18. Volume-effect and radiotherapy [2]. Part 2: volume-effect and normal tissue; Effet volume en radiotherapie [2]. Deuxieme partie: volume et tolerance des tissus sains

    Energy Technology Data Exchange (ETDEWEB)

    Huchet, A.; Caudry, M.; Trouette, R.; Vendrely, V.; Causse, N.; Recaldini, L.; Maire, J.P. [Hopital Saint Andre, Service de Radiotherapie, 33 - Bordeaux (France); Belkacemi, Y. [Centre de Lutte Contre le Cancer Oscar-Lambret, Dept. de Radiotherapie, 59 - Lille (France); Atlan, D. [Hopital Europeen Georges Pompidou, Service de Radiotherapie, 75 - Paris (France)

    2003-10-01

    The first part of our work has focused on the relationship bet men tumor Volume and tumor control. Indeed, it is well known that the importance of irradiated volume could be a main parameter of radiation-induced complications. Numerous mathematical models have described the correlation between the irradiated volume and the risk of adverse effects. These models should predict the complication rate of each treatment planning. At the present time late effects have been the most studied. In this report we firstly propose a review of different mathematical models described for volume effect. Secondly, we will discuss whether these theoretical considerations can influence our view of radiation treatment planning optimization. (authors)

  19. Activity report 1990-1992 and proceedings, volume 1

    Science.gov (United States)

    Mayer-Rosa, D.; Waniek, L.; Suhadolc, P.

    A report on the activities of the European Seismological Commission (ESC) during the period 1990-1992 together with the Proceedings of the General Assembly of the ESC are presented in two volumes. Volume 1 covers the following topics: recent strong earthquakes in Europe, regional seismicity, historical earthquakes in Europe, statistical models and methods in seismology, numerical modeling in three-dimensional media, methodology of quantification of European earthquakes and recent results, seismic noise and signal detectability, regional seismic network, and history of seismometry. One paper dealing with microseismic noise characteristics around the Kozloduy nuclear power plant has been inputted to INIS.

  20. Instrumentation for Environmental Monitoring: Water, Volume 2.

    Science.gov (United States)

    California Univ., Berkeley. Lawrence Berkeley Lab.

    This volume is one of a series discussing instrumentation for environmental monitoring. Each volume contains an overview of the basic problems, comparisons among the basic methods of sensing and detection, and notes that summarize the characteristics of presently available instruments and techniques. The text of this survey discusses the…

  1. Developmental Physical Education Accountability; Volume I.

    Science.gov (United States)

    Guarnieri, Barbara; Sandeen, Cecile

    Presented in the first of a two volume series is a developmental physical education checklist which provides teachers of trainable mentally retarded students with a permanent and accountable record of pupil progress and needs. The checklist is intended to be used with the accompanying volume of curricular activities in a nongraded enviroment for…

  2. Culture of Schools. Final Report. Volume I.

    Science.gov (United States)

    American Anthropological Association, Washington, DC.

    The first volume of this 4-volume report presents the basic rationale for an anthropological and cross-cultural approach to education, abstracts of 14 research projects sponsored by the American Anthropological Association, a proposal for the establishment of a Research Center for Anthropology and Education to be coordinated by the Association, a…

  3. Image plane sweep volume illumination.

    Science.gov (United States)

    Sundén, Erik; Ynnerman, Anders; Ropinski, Timo

    2011-12-01

    In recent years, many volumetric illumination models have been proposed, which have the potential to simulate advanced lighting effects and thus support improved image comprehension. Although volume ray-casting is widely accepted as the volume rendering technique which achieves the highest image quality, so far no volumetric illumination algorithm has been designed to be directly incorporated into the ray-casting process. In this paper we propose image plane sweep volume illumination (IPSVI), which allows the integration of advanced illumination effects into a GPU-based volume ray-caster by exploiting the plane sweep paradigm. Thus, we are able to reduce the problem complexity and achieve interactive frame rates, while supporting scattering as well as shadowing. Since all illumination computations are performed directly within a single rendering pass, IPSVI does not require any preprocessing nor does it need to store intermediate results within an illumination volume. It therefore has a significantly lower memory footprint than other techniques. This makes IPSVI directly applicable to large data sets. Furthermore, the integration into a GPU-based ray-caster allows for high image quality as well as improved rendering performance by exploiting early ray termination. This paper discusses the theory behind IPSVI, describes its implementation, demonstrates its visual results and provides performance measurements.

  4. Making your presentation fun: creative presentation techniques

    Energy Technology Data Exchange (ETDEWEB)

    KEENEN,MARTHA JANE

    2000-05-18

    What possesses someone to volunteer and go through hoops and red tape to make a presentation at a conference? For that matter, why does anyone ever present anything to anyone? Actually, presentations are a fact of life and there are many reasons for doing a presentation and doing it well. New and existing staff need training and orientation to the way things are done here. Handing all of them a manual and hoping they read it is pretty much a waste of paper. On the other hand, an effective, entertaining and upbeat presentation on the relevant topics is more likely to stick with those people. They will even have a name and face to remember and seek out when they have an issue on or with that topic. This can be a very effective beginning for networking with new peers. The presenter is seen as knowledgeable, as a source of information on company topics and possibly evaluated as a potential mentor or future manager. Project staff and/or peers benefit from clear, concise, presentations of topical knowledge. This is one way that a group working on various aspects of the same project or program can stay in touch and in step with each other. Most importantly, presentations may be the best or only door into the minds (and budgets) of management and customers. These presentations are a wonderful opportunity to address legal and compliance issues, budget, staffing, and services. Here is a chance, maybe the only one, to demonstrate and explain the wonderfulness of a program and the benefit they get by using the services offered most effectively. An interactive presentation on legal and compliance issues can be an effective tool in helping customers and/or management make good risk management decisions.

  5. Gas volume contents within a container, smart volume instrument

    Science.gov (United States)

    Kelley, Anthony R. (Inventor); Van Buskirk, Paul D. (Inventor)

    2008-01-01

    A method for determining the volume of an incompressible gas in a system including incompressible substances in a zero-gravity environment. The method includes inducing a volumetric displacement within a container and measuring the resulting pressure change. From this data, the liquid level can be determined.

  6. Scan-based volume animation driven by locally adaptive articulated registrations.

    Science.gov (United States)

    Rhee, Taehyun; Lewis, J P; Neumann, Ulrich; Nayak, Krishna S

    2011-03-01

    This paper describes a complete system to create anatomically accurate example-based volume deformation and animation of articulated body regions, starting from multiple in vivo volume scans of a specific individual. In order to solve the correspondence problem across volume scans, a template volume is registered to each sample. The wide range of pose variations is first approximated by volume blend deformation (VBD), providing proper initialization of the articulated subject in different poses. A novel registration method is presented to efficiently reduce the computation cost while avoiding strong local minima inherent in complex articulated body volume registration. The algorithm highly constrains the degrees of freedom and search space involved in the nonlinear optimization, using hierarchical volume structures and locally constrained deformation based on the biharmonic clamped spline. Our registration step establishes a correspondence across scans, allowing a data-driven deformation approach in the volume domain. The results provide an occlusion-free person-specific 3D human body model, asymptotically accurate inner tissue deformations, and realistic volume animation of articulated movements driven by standard joint control estimated from the actual skeleton. Our approach also addresses the practical issues arising in using scans from living subjects. The robustness of our algorithms is tested by their applications on the hand, probably the most complex articulated region in the body, and the knee, a frequent subject area for medical imaging due to injuries.

  7. Peripheral telomere length and hippocampal volume in adolescents with major depressive disorder.

    Science.gov (United States)

    Henje Blom, E; Han, L K M; Connolly, C G; Ho, T C; Lin, J; LeWinn, K Z; Simmons, A N; Sacchet, M D; Mobayed, N; Luna, M E; Paulus, M; Epel, E S; Blackburn, E H; Wolkowitz, O M; Yang, T T

    2015-11-10

    Several studies have reported that adults with major depressive disorder have shorter telomere length and reduced hippocampal volumes. Moreover, studies of adult populations without major depressive disorder suggest a relationship between peripheral telomere length and hippocampal volume. However, the relationship of these findings in adolescents with major depressive disorder has yet to be explored. We examined whether adolescent major depressive disorder is associated with altered peripheral telomere length and hippocampal volume, and whether these measures relate to one another. In 54 unmedicated adolescents (13-18 years) with major depressive disorder and 63 well-matched healthy controls, telomere length was assessed from saliva using quantitative polymerase chain reaction methods, and bilateral hippocampal volumes were measured with magnetic resonance imaging. After adjusting for age and sex (and total brain volume in the hippocampal analysis), adolescents with major depressive disorder exhibited significantly shorter telomere length and significantly smaller right, but not left hippocampal volume. When corrected for age, sex, diagnostic group and total brain volume, telomere length was not significantly associated with left or right hippocampal volume, suggesting that these cellular and neural processes may be mechanistically distinct during adolescence. Our findings suggest that shortening of telomere length and reduction of hippocampal volume are already present in early-onset major depressive disorder and thus unlikely to be only a result of accumulated years of exposure to major depressive disorder.

  8. Percutaneous closure of atrial septal defects leads to normalisation of atrial and ventricular volumes

    Directory of Open Access Journals (Sweden)

    Worthley Matthew I

    2008-12-01

    Full Text Available Abstract Background Percutaneous closure of atrial septal defects (ASDs should potentially reduce right heart volumes by removing left-to-right shunting. Due to ventricular interdependence, this may be associated with impaired left ventricular filling and potentially function. Furthermore, atrial changes post-ASD closure have been poorly understood and may be important for understanding risk of atrial arrhythmia post-ASD closure. Cardiovascular magnetic resonance (CMR is an accurate and reproducible imaging modality for the assessment of cardiac function and volumes. We assessed cardiac volumes pre- and post-percutaneous ASD closure using CMR. Methods Consecutive patients (n = 23 underwent CMR pre- and 6 months post-ASD closure. Steady state free precession cine CMR was performed using contiguous slices in both short and long axis views through the ASD. Data was collected for assessment of left and right atrial, ventricular end diastolic volumes (EDV and end systolic volumes (ESV. Data is presented as mean ± SD, volumes as mL, and paired t-testing performed between groups. Statistical significance was taken as p Results There was a significant reduction in right ventricular volumes at 6 months post-ASD closure (RVEDV: 208.7 ± 76.7 vs. 140.6 ± 60.4 mL, p Conclusion ASD closure leads to normalisation of ventricular volumes and also a reduction in right atrial volume. Further follow-up is required to assess how this predicts outcomes such as risk of atrial arrhythmias after such procedures.

  9. Insular volume reduction in schizophrenia.

    Science.gov (United States)

    Saze, Teruyasu; Hirao, Kazuyuki; Namiki, Chihiro; Fukuyama, Hidenao; Hayashi, Takuji; Murai, Toshiya

    2007-12-01

    Structural and functional abnormalities of the insular cortex have been reported in patients with schizophrenia. Most studies have shown that the insular volumes in schizophrenia patients are smaller than those of healthy people. As the insular cortex is functio-anatomically divided into anterior and posterior subdivisons, recent research is focused on uncovering a specific subdivisional abnormality of the insula in patients with schizophrenia. A recent ROI-based volumetric MRI study demonstrated specific left anterior insular volume reduction in chronic schizophrenia patients (Makris N, Goldstein J, Kennedy D, Hodge S, Caviness V, Faraone S, Tsuang M, Seidman L (2006) Decreased volume of left and total anterior insular lobule in schizophrenia. Schizophr Res 83:155-171). On the other hand, our VBM-based volumetric study revealed a reduction in right posterior insular volume (Yamada M, Hirao K, Namiki C, Hanakawa T, Fukuyama H, Hayashi T, Murai T (2007) Social cognition and frontal lobe pathology in schizophrenia: a voxel-based morphometric study. NeuroImage 35:292-298). In order to address these controversial results, ROI-based subdivisional volumetry was performed using the MRI images from the same population we analyzed in our previous VBM-study. The sample group comprised 20 schizophrenia patients and 20 matched healthy controls. Patients with schizophrenia showed a global reduction in insular gray matter volumes relative to healthy comparison subjects. In a simple comparison of the volumes of each subdivision between the groups, a statistically significant volume reduction in patients with schizophrenia was demonstrated only in the right posterior insula. This study suggests that insular abnormalities in schizophrenia would include anterior as well as posterior parts. Each subdivisional abnormality may impact on different aspects of the pathophysiology and psychopathology of schizophrenia; these relationships should be the focus of future research.

  10. Correlation among body height, intelligence, and brain gray matter volume in healthy children.

    Science.gov (United States)

    Taki, Yasuyuki; Hashizume, Hiroshi; Sassa, Yuko; Takeuchi, Hikaru; Asano, Michiko; Asano, Kohei; Kotozaki, Yuka; Nouchi, Rui; Wu, Kai; Fukuda, Hiroshi; Kawashima, Ryuta

    2012-01-16

    A significant positive correlation between height and intelligence has been demonstrated in children. Additionally, intelligence has been associated with the volume of gray matter in the brains of children. Based on these correlations, we analyzed the correlation among height, full-scale intelligence quotient (IQ) and gray matter volume applying voxel-based morphometry using data from the brain magnetic resonance images of 160 healthy children aged 5-18 years of age. As a result, body height was significantly positively correlated with brain gray matter volume. Additionally, the regional gray matter volume of several regions such as the bilateral prefrontal cortices, temporoparietal region, and cerebellum was significantly positively correlated with body height and that the gray matter volume of several of these regions was also significantly positively correlated with full-scale intelligence quotient (IQ) scores after adjusting for age, sex, and socioeconomic status. Our results demonstrate that gray and white matter volume may mediate the correlation between body height and intelligence in healthy children. Additionally, the correlations among gray and white matter volume, height, and intelligence may be at least partially explained by the effect of insulin-like growth factor-1 and growth hormones. Given the importance of the effect of environmental factors, especially nutrition, on height, IQ, and gray matter volume, the present results stress the importance of nutrition during childhood for the healthy maturation of body and brain. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Analysis of radioactivity levels in the surrounding of the Aube storage plant (F.M.A.-V.C.). year 2007. Presentation, results and methods; Analyse des niveaux de la radioactivite dans les environs du centre de stockage F.M.A.-V.C. de l'Aube. Annee 2007. Presentation, resultats et methodes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    The study had three objectives: to collect information that explain the impact of the Aube storage center (C.S.A.) on environment and allow to evaluate the consequences for man, secondly, to build a referential for any future inquiry or follow-up, thirdly, to allow to the local commission of information to elaborate an information towards the side residents and local actors that take into account their questions. Trees, waters, sediments, soils, grass, products of gardens and vineyards were the object of sampling, their dosimetry is given in this report. Other dosimetry measures were made along the nuclear site and the results are equally in this report. (N.C.)

  12. Uncertainty-aware guided volume segmentation.

    Science.gov (United States)

    Prassni, Jörg-Stefan; Ropinski, Timo; Hinrichs, Klaus

    2010-01-01

    Although direct volume rendering is established as a powerful tool for the visualization of volumetric data, efficient and reliable feature detection is still an open topic. Usually, a tradeoff between fast but imprecise classification schemes and accurate but time-consuming segmentation techniques has to be made. Furthermore, the issue of uncertainty introduced with the feature detection process is completely neglected by the majority of existing approaches.In this paper we propose a guided probabilistic volume segmentation approach that focuses on the minimization of uncertainty. In an iterative process, our system continuously assesses uncertainty of a random walker-based segmentation in order to detect regions with high ambiguity, to which the user's attention is directed to support the correction of potential misclassifications. This reduces the risk of critical segmentation errors and ensures that information about the segmentation's reliability is conveyed to the user in a dependable way. In order to improve the efficiency of the segmentation process, our technique does not only take into account the volume data to be segmented, but also enables the user to incorporate classification information. An interactive workflow has been achieved by implementing the presented system on the GPU using the OpenCL API. Our results obtained for several medical data sets of different modalities, including brain MRI and abdominal CT, demonstrate the reliability and efficiency of our approach.

  13. Volume Regulated Channels

    DEFF Research Database (Denmark)

    Klausen, Thomas Kjær

    - serves a multitude of functions in the mammalian cell, regulating the membrane potential (Em), cell volume, protein activity and the driving force for facilitated transporters giving Cl- and Cl- channels a major potential of regulating cellular function. These functions include control of the cell cycle...... of volume perturbations evolution have developed system of channels and transporters to tightly control volume homeostasis. In the past decades evidence has been mounting, that the importance of these volume regulated channels and transporters are not restricted to the defense of cellular volume......, controlled cell death and cellular migration. Volume regulatory mechanisms has long been in focus for regulating cellular proliferation and my thesis work have been focusing on the role of Cl- channels in proliferation with specific emphasis on ICl, swell. Pharmacological blockage of the ubiquitously...

  14. Multidisciplinary studies of the social, economic and political impact resulting from recent advances in satellite meteorology. Volume 6: Executive summary. [technological forecasting spacecraft control/attitude (inclination) -classical mechanics

    Science.gov (United States)

    1975-01-01

    An assessment of the technological impact of modern satellite weather forecasting for the United States is presented. Topics discussed are: (1) television broadcasting of weather; (2) agriculture (crop production); (3) water resources; (4) urban development; (5) recreation; and (6) transportation.

  15. Perm Web: remote parallel and distributed volume visualization

    Energy Technology Data Exchange (ETDEWEB)

    Wittenbrink, C.M.; Kim, K.; Story, J.; Pang, A.; Hollerbach, K.; Max, N.

    1997-01-01

    In this paper we present a system for visualizing volume data from remote supercomputers (PermWeb). We have developed both parallel volume rendering algorithms, and the World Wide Web software for accessing the data at the remote sites. The implementation uses Hypertext Markup Language (HTML), Java, and Common Gateway Interface (CGI) scripts to connect World Wide Web (WWW) servers/clients to our volume renderers. The front ends are interactive Java classes for specification of view, shading, and classification inputs. We present performance results, and implementation details for connections to our computing resources at the University of California Santa Cruz including a MasPar MP-2, SGI Reality Engine-RE2, and SGI Challenge machines. We apply the system to the task of visualizing trabecular bone from finite element simulations. Fast volume rendering on remote compute servers through a web interface allows us to increase the accessibility of the results to more users. User interface issues, overviews of parallel algorithm developments, and overall system interfaces and protocols are presented. Access is available through Uniform Resource Locator (URL) http://www.cse.ucsc.edu/research/slvg/. 26 refs., 7 figs.

  16. Determination of right ventricular volumes during aortic surgery.

    Science.gov (United States)

    Van der Linden, P; Gilbart, E; Engelman, E; de Rood, M; Vincent, J L

    1989-06-01

    The aim of the present study was to evaluate right ventricular (RV) preload by measurements of right ventricular volumes during aortic clamping and unclamping. Nine patients (aged 67 +/- 9 years) undergoing infrarenal aortic aneurysmectomy were monitored with a pulmonary artery catheter equipped with a fast-response thermistor, allowing determination of RV volumes by the thermodilution technique. Anesthesia consisted of a continuous infusion of alfentanil and 50% N2O. Aortic clamping resulted in a significant decrease in cardiac index (CI) and a significant increase in systemic vascular resistance (SVR). There was no significant change in right ventricular ejection fraction (RVEF) (from 35% +/- 6% to 33% +/- 8%) in the presence of a significant decrease in stroke index (from 37.2 +/- 9.8 to 31.1 +/- 10.0 mL/beat/m2, P less than 0.05), indicating a significant decrease in RV end-diastolic volume (from 106 +/- 17 to 92 +/- 19 mL, P less than 0.01). There were no significant changes in cardiac filling pressures. Aortic unclamping was associated with a significant increase in CI and a significant decrease in SVR. There were no significant changes in cardiac filling pressures, RVEF, or RV volumes. Measurements of RV volumes indicated that aortic clamping resulted in a decrease in RV preload, which is usually not demonstrated by measurements of right atrial pressure alone.

  17. Vol(2)velle: Printable Interactive Volume Visualization.

    Science.gov (United States)

    Stoppel, Sergej; Bruckner, Stefan

    2017-01-01

    Interaction is an indispensable aspect of data visualization. The presentation of volumetric data, in particular, often significantly benefits from interactive manipulation of parameters such as transfer functions, rendering styles, or clipping planes. However, when we want to create hardcopies of such visualizations, this essential aspect is lost. In this paper, we present a novel approach for creating hardcopies of volume visualizations which preserves a certain degree of interactivity. We present a method for automatically generating Volvelles, printable tangible wheel charts that can be manipulated to explore different parameter settings. Our interactive system allows the flexible mapping of arbitrary visualization parameters and supports advanced features such as linked views. The resulting designs can be easily reproduced using a standard printer and assembled within a few minutes.

  18. Search and Result Presentation in Scientific Workflow Repositories

    OpenAIRE

    Davidson, Susan B.; Huang, Xiaocheng; Stoyanovich, Julia; Yuan, Xiaojie

    2013-01-01

    We study the problem of searching a repository of complex hierarchical workflows whose component modules, both composite and atomic, have been annotated with keywords. Since keyword search does not use the graph structure of a workflow, we develop a model of workflows using context-free bag grammars. We then give efficient polynomial-time algorithms that, given a workflow and a keyword query, determine whether some execution of the workflow matches the query. Based on these algorithms we deve...

  19. [Volume replenishment in haemorrhage: caution advised].

    Science.gov (United States)

    Kooter, Albertus J; Zweegman, Sonja; Smulders, Yvo M

    2011-01-01

    Acute haemorrhage is a frequent problem in medicine. Patients with acute bleeding may present with signs of hypotension and reduced organ perfusion. The physician's reflex action is often to treat such patients with intravenous volume replenishment using colloid or cristalloid liquids. Intravenous volume replenishment has, however, a downside: it increases the tendency to bleed and therefore can increase blood loss. Previous clinical observations and experimental animal and human studies addressing volume replenishment in haemorrhagic shock have repeatedly shown that accepting hypotension favourably affects prognosis. However, relevant practice guidelines, such as for gastrointestinal bleeding, usually advise liberal intravenous volume replenishment if hypotension is present. In this article we advocate caution when considering intravenous blood volume adjustment in haemorrhage.

  20. Volume estimation in a sequence of freehand ultrasound images

    Science.gov (United States)

    Zhang, Hongmei; Wan, Mingxi; Shen, Bo; Wang, Xiaodong; Lu, Mingzhu

    2006-11-01

    Volume estimation is particularly important in clinical medicine. Accurate volume estimation can provide quantitative information from which the follow-up therapy can be derived. In this paper, an efficient approach to volume estimation in a sequence of freehand ultrasound images is proposed. By integral of vector areas along the path of centroids of serial cross-sections, 3D volume estimation can be represented as 2D area calculation, where a fast mapping algorithm generating 2D representation is presented so that the position of interpolation points can be calculated with high efficiency. Meanwhile, to improve the accuracy, the cubic spline with second-order continuity is proposed for interpolation of 2D representation. Volume estimation on simulating phantoms for parallel cutting, fan cutting and random cuttings is provided. The experimental results show that the 2D representation generated by the fast mapping algorithm is highly efficient with less than 0.001 ms for 100 cross-sections. Quantitative comparisons show that the proposed interpolation method can approximate the original volume more precisely as compared to the Catmull-Rom (CR) spline, especially in the case of small number of cross-sections. In all cases, our approach can obtain accurate results at an error of less than 2% for ten cross-sections. Additionally, volume estimation on a high intensity focused ultrasound (HIFU) lesion based on linear B-scan and rotational B-scan sequential images are also performed. The experiments show that the proposed approach is promising and may have potential in clinical applications.

  1. Precision volume measurement system.

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Erin E.; Shugard, Andrew D.

    2004-11-01

    A new precision volume measurement system based on a Kansas City Plant (KCP) design was built to support the volume measurement needs of the Gas Transfer Systems (GTS) department at Sandia National Labs (SNL) in California. An engineering study was undertaken to verify or refute KCP's claims of 0.5% accuracy. The study assesses the accuracy and precision of the system. The system uses the ideal gas law and precise pressure measurements (of low-pressure helium) in a temperature and computer controlled environment to ratio a known volume to an unknown volume.

  2. Monitoring and Evaluation of Smolt Migration in the Columbia Basin : Volume XVIII: Survival and Transportation Effects of Migrating Snake River Wild Chinook Salmon and Steelhead: Historical Estimates From 1996-2004 and Comparison to Hatchery Results. Draft.

    Energy Technology Data Exchange (ETDEWEB)

    Buchanan, Rebecca A.; Skalski, John R.; Broms, Kristin

    2008-12-03

    The combined juvenile and adult detection histories of PIT-tagged wild salmonids migrating through the Federal Columbia River Power System (FCRPS) were analyzed using the ROSTER (River-Ocean Survival and Transportation Effects Routine) statistical release-recapture model. This model, implemented by software Program ROSTER, was used to estimate survival on large temporal and spatial scales for PIT-tagged wild spring and summer Chinook salmon and steelhead released in the Snake River Basin upstream of Lower Granite Dam from 1996 to 2004. In addition, annual results from wild salmonids were compared with results from hatchery salmonids, which were presented in a previous report in this series (Buchanan, R. A., Skalski, J. R., Lady, J. L., Westhagen, P., Griswold, J., and Smith, S. 2007, 'Survival and Transportation Effects for Migrating Snake River Hatchery Chinook Salmon and Steelhead: Historical Estimates from 1996-2003', Technical report, Bonneville Power Administration, Project 1991-051-00). These results are reported here. Annual estimates of the smolt-to-adult return ratio (SAR), juvenile inriver survival from Lower Granite to Bonneville, the ocean return probability from Bonneville to Bonneville, and adult upriver survival from Bonneville to Lower Granite are reported. Annual estimates of transport-inriver (T/I) ratios and differential post-Bonneville mortality (D) are reported on a dam-specific basis for release years with sufficient numbers of wild PIT-tagged smolts transported. Transportation effects are estimated only for dams where at least 1,000 tagged wild smolts were transported from a given upstream release group. Because few wild Chinook salmon and steelhead tagged upstream of Lower Granite Dam were transported before the 2003 release year, T/I and D were estimated only for the 2003 and 2004 release years. Performance measures include age-1-ocean adult returns for steelhead, but not for Chinook salmon. Spring and summer Chinook salmon

  3. Early adverse events, HPA activity and rostral anterior cingulate volume in MDD.

    Directory of Open Access Journals (Sweden)

    Michael T Treadway

    Full Text Available BACKGROUND: Prior studies have independently reported associations between major depressive disorder (MDD, elevated cortisol concentrations, early adverse events and region-specific decreases in grey matter volume, but the relationships among these variables are unclear. In the present study, we sought to evaluate the relationships between grey matter volume, early adverse events and cortisol levels in MDD. METHODS/RESULTS: Grey matter volume was compared between 19 controls and 19 individuals with MDD using voxel-based morphometry. A history of early adverse events was assessed using the Childhood Trauma Questionnaire. Subjects also provided salivary cortisol samples. Depressed patients showed decreased grey matter volume in the rostral ACC as compared to controls. Rostral ACC volume was inversely correlated with both cortisol and early adverse events. CONCLUSIONS: These findings suggest a key relationship between ACC morphology, a history of early adverse events and circulating cortisol in the pathophysiology of MDD.

  4. State of the art review of radioactive waste volume reduction techniques for commercial nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    1980-04-01

    A review is made of the state of the art of volume reduction techniques for low level liquid and solid radioactive wastes produced as a result of: (1) operation of commercial nuclear power plants, (2) storage of spent fuel in away-from-reactor facilities, and (3) decontamination/decommissioning of commercial nuclear power plants. The types of wastes and their chemical, physical, and radiological characteristics are identified. Methods used by industry for processing radioactive wastes are reviewed and compared to the new techniques for processing and reducing the volume of radioactive wastes. A detailed system description and report on operating experiences follow for each of the new volume reduction techniques. In addition, descriptions of volume reduction methods presently under development are provided. The Appendix records data collected during site surveys of vendor facilities and operating power plants. A Bibliography is provided for each of the various volume reduction techniques discussed in the report.

  5. Comparison of uncertainties related to standardization of urine samples with volume and creatinine concentration

    DEFF Research Database (Denmark)

    Garde, Anne Helene; Hansen, Ase Marie; Kristiansen, Jesper;

    2004-01-01

    When measuring biomarkers in urine, volume (and time) or concentration of creatinine are both accepted methods of standardization for diuresis. Both types of standardization contribute uncertainty to the final result. The aim of the present paper was to compare the uncertainty introduced when using...... that the uncertainty associated with creatinine standardization (19-35%) was higher than the uncertainty related to volume standardization (up to 10%, when not correcting for deviations from 24 h) for 24 h urine samples. However, volume standardization introduced an average bias of 4% due to missed volumes...... in population studies. When studying a single 24 h sample from one individual, there was a 15-20% risk that the sample was incomplete. In this case a bias of approximately 25% was introduced when using volume standardization, whereas the uncertainty related to creatinine standardization was independent...

  6. Three-dimensional active net for volume extraction

    Science.gov (United States)

    Takanashi, Ikuko; Muraki, Shigeru; Doi, Akio; Kaufman, Arie E.

    1998-05-01

    3D Active Net, which is a 3D extension of Snakes, is an energy-minimizing surface model which can extract a volume of interest from 3D volume data. It is deformable and evolves in 3D space to be attracted to salient features, according to its internal and image energy. The net can be fitted to the contour of a target object by defining the image energy suitable for the contour property. We present testing results of the extraction of a muscle from the Visible Human Data by two methods: manual segmentation and the application of 3D Active Net. We apply principal component analysis, which utilizes the color information of the 3D volume data to emphasize an ill-defined contour of the muscle, and then apply 3D Active Net. We recognize that the extracted object has a smooth and natural contour in contrast with a comparable manual segmentation, proving an advantage of our approach.

  7. Compulsive Sexual Behavior: Prefrontal and Limbic Volume and Interactions

    DEFF Research Database (Denmark)

    Schmidt, Casper; Morris, Laurel S.; Kvamme, Timo L.

    2017-01-01

    Background: Compulsive sexual behaviors (CSB) are relatively common and associated with significant personal and social dysfunction. The underlying neurobiology is still poorly understood. The present study examines brain volumes and resting state functional connectivity in CSB compared...... with matched healthy volunteers (HV). Methods: Structural MRI (MPRAGE) data were collected in 92 subjects (23 CSB males and 69 age-matched male HV) and analyzed using voxel-based morphometry. Resting state functional MRI data using multi-echo planar sequence and independent components analysis (ME-ICA) were...... collected in 68 subjects (23 CSB subjects and 45 age-matched HV). Results: CSB subjects showed greater left amygdala gray matter volumes (small volume corrected, Bonferroni adjusted P functional connectivity between the left amygdala seed and bilateral dorsolateral...

  8. EVALUATION OF NO SEGMENTED TAPER MODELS TO ESTIMATE HEIGHT AND MERCHANTABLE VOLUME FROM Eucalyptus sp. STEMS

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Martinelli de Souza

    2009-10-01

    Full Text Available This work aimed to evaluate different taper models in the estimate of the merchantable height and volume and along the bole volumes of Eucalyptus sp., to the obtention of multiproducts. Considering the data of rigorous scaling of trees of Eucalyptus sp. with 16 years-old, it was appraised the models of taper of Demaerschalk (1972, Ormerod (1973, Schöepfer (1966, Hradetzky (1976, Garay (1979 and Biging (1984. Based on graphical analysis of the residues and on the statistics bias (B, average of the differences (MD and deviation pattern of the differences (DPD, it could be verified that, in the estimate of the merchantable height and volume of the models, Biging, Schöepfer and Hradetzky presented the best results, followed by the models of Garay, which have also shown good results. In general, considering the treatment of the volumes of the logs, the Biging model presented the best resuts.

  9. Basic research of the relationship between irradiation dose and volume in radiation-induced pulmonary injury

    Institute of Scientific and Technical Information of China (English)

    PANG Qing-song; WANG Ping; WANG Jing; WANG Wei; WANG Jun; YUAN Zhi-yong

    2009-01-01

    Background Irradiation dose and volume are the major physical factors of radiation-induced lung injury.The study investigated the relationships between the irradiation dose and volume in radiation-induced lung injury by setting up a model of graded volume irradiation of the rat lung.Methods Animals were randomly assigned to three groups.The ELEKTA precise 2.03 treatment plan system was applied to calculate the irradiation dose and volume.The treatment plan for the three groups was:group 1 received a "high dose to a small volume" (25% volume group) with the mean irradiation volume being 1.748 cm3 (25% lung volume);the total dose and mean lung dose (MLD) were 4610 cGy and 2006 cGy,respectively (bilateral AP-PA fields,source to axis distance (SAD)=100 cm,6MVX,single irradiation);Group 2 received a "low dose to a large volume" (100% volume group) with the mean irradiation volume being 6.99 cm3 (100% lung volume);the total dose was 1153 cGy.MLD was 2006 cGy,which was the same as that of group 1 (bilateral AP-PA fields,SAD = 100 cm,6MVX,single irradiation);Group 3 was a control group.With the exception of receiving no irradiation,group 3 had rest steps that were the same as those of the experimental groups.After irradiation,functional,histopathological,and CT changes were compared every two weeks till the 16th week.Results Functionally,after irradiation breath rate (BR) increases were observed in both group 1 and group 2,especially during the period of 6th-8th weeks.The changes of BR in the 100% volume group were earlier and faster.For the 25% volume group,although pathology was more severe,hardly any obvious increase in BR was observed.Radiographic changes were observed during the early period (the 4th week) and the most obvious changes manifested during the mediated period (the 8th week).The extensiveness of high density and the decreased lung permeability were presented in the 100% volume group,and ground glass opacity and patchy consolidation were presented in the 25

  10. The history of NATO TNF policy: The role of studies, analysis and exercises conference proceedings. Volume 1, Introduction and summary

    Energy Technology Data Exchange (ETDEWEB)

    Rinne, R.L. [ed.

    1994-02-01

    This conference was organized to study and analyze the role of simulation, analysis, modeling, and exercises in the history of NATO policy. The premise was not that the results of past studies will apply to future policy, but rather that understanding what influenced the decision process -- and how -- would be of value. The structure of the conference was built around discussion panels. The panels were augmented by a series of papers and presentations focusing on particular TNF events, issues, studies or exercise. The conference proceedings consist of three volumes. This volume, Volume 1, contains the conference introduction, agenda, biographical sketches of principal participants, and analytical summary of the presentations and discussion panels. Volume 2 contains a short introduction and the papers and presentations from the conference. Volume 3 contains selected papers by Brig. Gen. Robert C. Richardson III (Ret.).

  11. Can body volume be determined by PET?

    Science.gov (United States)

    Hentschel, Michael; Paul, Dominik; Korsten-Reck, Ulrike; Mix, Michael; Müller, Frank; Merk, Stefan; Moser, Ernst; Brink, Ingo

    2005-05-01

    To avoid dependence on body weight, the standardised uptake value (SUV) in positron emission tomography (PET) can instead be normalised to the lean body mass (LBM), which can be determined from body volume and mass. This study was designed to answer the following questions: Firstly, can the total body volume in principle be determined using PET? Secondly, is the precision of this measurement comparable to that achieved using an established standard method. Ten patients were examined during oncological whole-body PET examinations. The whole-body volume of the patients was determined from the transmission scan in PET. Air displacement plethysmography with BOD POD was used for comparison as the standard method of volume determination. In all patients, the whole-body volumes could be determined using PET and the standard method. Bland and Altman [23] analysis for agreement between the volumes determined by the two methods (presentation of differences vs means) revealed a very small difference of -0.14 l. With a mean patient volume of 71.81+/-15.93 l, the relative systematic error is only <0.1%. On this basis, equality of the volume values determined by the two methods can be assumed. PET can be used as a supplementary method for experimental determination of whole-body volume and total body fat in tumour patients. The fat content can be used to calculate the LBM and to determine body weight-independent SUVs (SUV(LBM)).

  12. Can body volume be determined by PET?

    Energy Technology Data Exchange (ETDEWEB)

    Hentschel, Michael; Paul, Dominik; Mix, Michael; Moser, Ernst; Brink, Ingo [University Hospital Freiburg, Division of Nuclear Medicine, Section of Positron Emission Tomography, Freiburg (Germany); Korsten-Reck, Ulrike [University Hospital Freiburg, Division of Sports Medicine, Freiburg (Germany); Mueller, Frank [PET-Institute Rhein-Neckar, Ludwigshafen (Germany); Merk, Stefan [Kantonsspital Basel, Division of Nuclear Medicine, Basel (Switzerland)

    2005-04-01

    To avoid dependence on body weight, the standardised uptake value (SUV) in positron emission tomography (PET) can instead be normalised to the lean body mass (LBM), which can be determined from body volume and mass. This study was designed to answer the following questions: Firstly, can the total body volume in principle be determined using PET? Secondly, is the precision of this measurement comparable to that achieved using an established standard method. Ten patients were examined during oncological whole-body PET examinations. The whole-body volume of the patients was determined from the transmission scan in PET. Air displacement plethysmography with BOD POD was used for comparison as the standard method of volume determination. In all patients, the whole-body volumes could be determined using PET and the standard method. Bland and Altman [23] analysis for agreement between the volumes determined by the two methods (presentation of differences vs means) revealed a very small difference of -0.14 l. With a mean patient volume of 71.81{+-}15.93 l, the relative systematic error is only <0.1%. On this basis, equality of the volume values determined by the two methods can be assumed. PET can be used as a supplementary method for experimental determination of whole-body volume and total body fat in tumour patients. The fat content can be used to calculate the LBM and to determine body weight-independent SUVs (SUV{sub LBM}). (orig.)

  13. A Flight Investigation of Control, Display, and Guidance Requirements for Decelerating Descending VTOL Instrument Transitions using the X-22A Variable Stability Aircraft. Volume 1. Technical Discussion and Results

    Science.gov (United States)

    1975-09-01

    airspeed/ground speed switching logic, configuration change command. 5.0 Selection of control system types , individual system characteristics...all five control system types in combination with the three most sophisticated display presentations is intended to provide some guidance in...deceleration profiles. 2. The required dynamic characteristics of the generic control system types investigated in this experiment should be

  14. Tumor Volumes and Prognosis in Laryngeal Cancer

    Directory of Open Access Journals (Sweden)

    Mohamad R. Issa

    2015-11-01

    Full Text Available Tumor staging systems for laryngeal cancer (LC have been developed to assist in estimating prognosis after treatment and comparing treatment results across institutions. While the laryngeal TNM system has been shown to have prognostic information, varying cure rates in the literature have suggested concern about the accuracy and effectiveness of the T-classification in particular. To test the hypothesis that tumor volumes are more useful than T classification, we conducted a retrospective review of 78 patients with laryngeal cancer treated with radiation therapy at our institution. Using multivariable analysis, we demonstrate the significant prognostic value of anatomic volumes in patients with previously untreated laryngeal cancer. In this cohort, primary tumor volume (GTVP, composite nodal volumes (GTVN and composite total volume (GTVP + GTVN = GTVC had prognostic value in both univariate and multivariate cox model analysis. Interestingly, when anatomic volumes were measured from CT scans after a single cycle of induction chemotherapy, all significant prognosticating value for measured anatomic volumes was lost. Given the literature findings and the results of this study, the authors advocate the use of tumor anatomic volumes calculated from pretreatment scans to supplement the TNM staging system in subjects with untreated laryngeal cancer. The study found that tumor volume assessment after induction chemotherapy is not of prognostic significance.

  15. Tumor Volumes and Prognosis in Laryngeal Cancer

    Science.gov (United States)

    Issa, Mohamad R.; Samuels, Stuart E.; Bellile, Emily; Shalabi, Firas L.; Eisbruch, Avraham; Wolf, Gregory

    2015-01-01

    Tumor staging systems for laryngeal cancer (LC) have been developed to assist in estimating prognosis after treatment and comparing treatment results across institutions. While the laryngeal TNM system has been shown to have prognostic information, varying cure rates in the literature have suggested concern about the accuracy and effectiveness of the T-classification in particular. To test the hypothesis that tumor volumes are more useful than T classification, we conducted a retrospective review of 78 patients with laryngeal cancer treated with radiation therapy at our institution. Using multivariable analysis, we demonstrate the significant prognostic value of anatomic volumes in patients with previously untreated laryngeal cancer. In this cohort, primary tumor volume (GTVP), composite nodal volumes (GTVN) and composite total volume (GTVP + GTVN = GTVC) had prognostic value in both univariate and multivariate cox model analysis. Interestingly, when anatomic volumes were measured from CT scans after a single cycle of induction chemotherapy, all significant prognosticating value for measured anatomic volumes was lost. Given the literature findings and the results of this study, the authors advocate the use of tumor anatomic volumes calculated from pretreatment scans to supplement the TNM staging system in subjects with untreated laryngeal cancer. The study found that tumor volume assessment after induction chemotherapy is not of prognostic significance. PMID:26569309

  16. MPCV Exercise Operational Volume Analysis

    Science.gov (United States)

    Godfrey, A.; Humphreys, B.; Funk, J.; Perusek, G.; Lewandowski, B. E.

    2017-01-01

    In order to minimize the loss of bone and muscle mass during spaceflight, the Multi-purpose Crew Vehicle (MPCV) will include an exercise device and enough free space within the cabin for astronauts to use the device effectively. The NASA Digital Astronaut Project (DAP) has been tasked with using computational modeling to aid in determining whether or not the available operational volume is sufficient for in-flight exercise.Motion capture data was acquired using a 12-camera Smart DX system (BTS Bioengineering, Brooklyn, NY), while exercisers performed 9 resistive exercises without volume restrictions in a 1g environment. Data were collected from two male subjects, one being in the 99th percentile of height and the other in the 50th percentile of height, using between 25 and 60 motion capture markers. Motion capture data was also recorded as a third subject, also near the 50th percentile in height, performed aerobic rowing during a parabolic flight. A motion capture system and algorithms developed previously and presented at last years HRP-IWS were utilized to collect and process the data from the parabolic flight [1]. These motions were applied to a scaled version of a biomechanical model within the biomechanical modeling software OpenSim [2], and the volume sweeps of the motions were visually assessed against an imported CAD model of the operational volume. Further numerical analysis was performed using Matlab (Mathworks, Natick, MA) and the OpenSim API. This analysis determined the location of every marker in space over the duration of the exercise motion, and the distance of each marker to the nearest surface of the volume. Containment of the exercise motions within the operational volume was determined on a per-exercise and per-subject basis. The orientation of the exerciser and the angle of the footplate were two important factors upon which containment was dependent. Regions where the exercise motion exceeds the bounds of the operational volume have been

  17. Wave energy devices with compressible volumes.

    Science.gov (United States)

    Kurniawan, Adi; Greaves, Deborah; Chaplin, John

    2014-12-08

    We present an analysis of wave energy devices with air-filled compressible submerged volumes, where variability of volume is achieved by means of a horizontal surface free to move up and down relative to the body. An analysis of bodies without power take-off (PTO) systems is first presented to demonstrate the positive effects a compressible volume could have on the body response. Subsequently, two compressible device variations are analysed. In the first variation, the compressible volume is connected to a fixed volume via an air turbine for PTO. In the second variation, a water column separates the compressible volume from another volume, which is fitted with an air turbine open to the atmosphere. Both floating and bottom-fixed, axisymmetric, configurations are considered, and linear analysis is employed throughout. Advantages and disadvantages of each device are examined in detail. Some configurations with displaced volumes less than 2000 m(3) and with constant turbine coefficients are shown to be capable of achieving 80% of the theoretical maximum absorbed power over a wave period range of about 4 s.

  18. An immunomagnetic separator for concentration of pathogenic micro-organisms from large volume samples

    Energy Technology Data Exchange (ETDEWEB)

    Rotariu, Ovidiu [School of Biological Sciences, University of Aberdeen, Cruickshank Building, St. Machar Drive, Aberdeen (United Kingdom) and National Institute of R-D for Technical Physics I.F.T. Iasi, Mangeron 47 Blvd., Iasi (Romania)]. E-mail: o.rotariu@abdn.ac.uk; Ogden, Iain D. [Department of Medical Microbiology, University of Aberdeen, Aberdeen (United Kingdom); MacRae, Marion [Department of Medical Microbiology, University of Aberdeen, Aberdeen (United Kingdom); Badescu, Vasile [National Institute of R-D for Technical Physics I.F.T. Iasi, Mangeron 47 Blvd., Iasi (Romania); Strachan, Norval J.C. [School of Biological Sciences, University of Aberdeen, Cruickshank Building, St. Machar Drive, Aberdeen (United Kingdom)

    2005-05-15

    The standard method of immunomagnetic separation of pathogenic bacteria from food and environmental matrices processes 1 ml volumes. Pathogens present at low levels (<1 pathogenic bacteria per ml) will not be consistently detected by this method. Here a flow through immunomagnetic separator (FTIMS) has been designed and tested to process large volume samples (>50 ml). Preliminary results show that between 70 and 113 times more Escherchia coli O157 are recovered compared with the standard 1 ml method.

  19. The analysis of subsidence associated with geothermal development. Volume 1. Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Atherton, R.W.; Finnemore, E.J.; Gillam, M.L.

    1976-09-01

    This study evaluates the state of knowledge of subsidence associated with geothermal development, and provides preliminary methods to assess the potential of land subsidence for any specific geothermal site. The results of this study are presented in three volumes. Volume 1 is designed to serve as a concise reference, a handbook, for the evaluation of the potential for land subsidence from the development of geothermal resources.

  20. COORDINATION BETWEEN RIBS MOTION AND THORACOABDOMINAL VOLUMES IN SWIMMERS DURING RESPIRATORY MANEUVERS

    OpenAIRE

    Karine J. Sarro; Barros, Ricardo M.L.; Silvatti, Amanda P.

    2008-01-01

    This work aimed to verify if swimmers present better chest wall coordination during breathing than healthy non-athletes analyzing the correlation between ribs motion and the variation of thoracoabdominal volumes. The results of two up-to-date methods based on videogrammetry were correlated in this study. The first one measured the volumes of 4 separate compartments of the chest wall (superior thorax, inferior thorax, superior abdomen and inferior abdomen) as a function of time. The second cal...

  1. Volume law for the entanglement entropy in non-local QFTs

    Energy Technology Data Exchange (ETDEWEB)

    Shiba, Noburo [Yukawa Institute for Theoretical Physics (YITP),Kyoto University,Kyoto 606-8502 (Japan); Takayanagi, Tadashi [Yukawa Institute for Theoretical Physics (YITP),Kyoto University,Kyoto 606-8502 (Japan); Kavli Institute for the Physics and Mathematics of the Universe,University of Tokyo,Kashiwa, Chiba 277-8582 (Japan)

    2014-02-07

    In this paper, we present a simple class of non-local field theories whose ground state entanglement entropy follows a volume law as long as the size of subsystem is smaller than a certain scale. We will confirm this volume law both from numerical calculations and from analytical estimation. This behavior fits nicely with holographic results for spacetimes whose curvatures are much smaller than AdS spaces such as those in the flat spacetime.

  2. Volume law for the entanglement entropy in non-local QFTs

    Science.gov (United States)

    Shiba, Noburo; Takayanagi, Tadashi

    2014-02-01

    In this paper, we present a simple class of non-local field theories whose ground state entanglement entropy follows a volume law as long as the size of subsystem is smaller than a certain scale. We will confirm this volume law both from numerical calculations and from analytical estimation. This behavior fits nicely with holographic results for spacetimes whose curvatures are much smaller than AdS spaces such as those in the flat spacetime.

  3. Volume Law for the Entanglement Entropy in Non-local QFTs

    CERN Document Server

    Shiba, Noburo

    2014-01-01

    In this paper, we present a simple class of non-local field theories whose ground state entanglement entropy follows a volume law as long as the size of subsystem is smaller than a certain scale. We will confirm this volume law both from numerical calculations and from analytical estimation. This behavior fits nicely with holographic results for spacetimes whose curvatures are much smaller than AdS spaces such as those in the flat spacetime.

  4. Large-Scale Operations Management Test of Use of the White Amur for Control of Problem Aquatic Plants. Report 2. First Year Poststocking Results. Volume II. The Fish, Mammals, and Waterfowl of Lake Conway, Florida.

    Science.gov (United States)

    1982-02-01

    were observed than in 1976-77, and yellow bullhead (Ictalurus natalis) and sailfin mollie (Poecilia latipinna) were captured for the first time in 1977...killifish 0.17 0.02 .-. 0.08 ( 0.99) ( 0.18) ... ( 0.51) Sailfin mollie .- - - Brook silverside ...... 0.33 - - - - - - ( 2.10) Bluespotted sunfish 0.17...affinis) or nine other principal nonmigratory species were 32 sighted. Principal wading birds present were great blue heron (Ardea herodias), green

  5. New Concepts in Fish Ladder Design, Volume II of IV, Results of Laboratory and Field Research on New Concepts in Weir and Pool Fishways, 1982-1984 Final Project Report.

    Energy Technology Data Exchange (ETDEWEB)

    Aaserude, Robert G.; Orsborn, John F.

    1985-08-01

    A comprehensive review of fishway design practice led to new design concepts that had previously been untested. This concept was based on the observation that fish can be stimulated to leap when presented with certain hydraulic conditions. A laboratory test program was conducted to develop this concept into a new fishway configuration. Field testing revealed that components of the new design improved fish passage. Verification of the initial premise that fish can be stimulated to leap needs further study.

  6. Space station accommodations for life sciences research facilities. Phase 1: Conceptual design and programmatics studies for Missions SAAX0307, SAAX0302 and the transition from SAAX0307 to SAAX0302. Volume 2: Study results

    Science.gov (United States)

    1986-01-01

    Lockheed Missiles and Space Company's conceptual designs and programmatics for a Space Station Nonhuman Life Sciences Research Facility (LSRF) are presented. Conceptual designs and programmatics encompass an Initial Orbital Capability (IOC) LSRF, a growth or follow-on Orbital Capability (FOC), and the transitional process required to modify the IOC LSFR to the FOC LSFR. The IOC and FOC LSFRs correspond to missions SAAX0307 and SAAX0302 of the Space Station Mission Requirements Database, respectively.

  7. Volume Regulated Channels

    DEFF Research Database (Denmark)

    Klausen, Thomas Kjær

    of volume perturbations evolution have developed system of channels and transporters to tightly control volume homeostasis. In the past decades evidence has been mounting, that the importance of these volume regulated channels and transporters are not restricted to the defense of cellular volume...... but are also essential for a number of physiological processes such as proliferation, controlled cell death, migration and endocrinology. The thesis have been focusing on two Channels, namely the swelling activated Cl- channel (ICl, swell) and the transient receptor potential Vanilloid (TRPV4) channel. I: Cl......- serves a multitude of functions in the mammalian cell, regulating the membrane potential (Em), cell volume, protein activity and the driving force for facilitated transporters giving Cl- and Cl- channels a major potential of regulating cellular function. These functions include control of the cell cycle...

  8. Rotational Crofton formulae for flagged intrinsic volumes

    DEFF Research Database (Denmark)

    Auneau, Jeremy Michel

    , and the integration is over all sections containing the fixed point origo. Our main result is a local stereological analogue to the well-known Crofton formula. More precisely, we derive geometric formulae that relate new flagged intrinsic volumes of a set with the flagged intrinsic volumes of its sections...

  9. Develop your presentation skills

    CERN Document Server

    Theobald, Theo

    2016-01-01

    Going beyond handling nerves and presenting PowerPoint slides, the third edition of "Develop Your Presentation Skills "offers practical advice on developing a captivating presentation, constructing compelling content, and boosting self-confidence. The book includes three new chapters on delivering a "stripped down"presentation, using new media to engage with the audience, and handling being asked to present on short notice."

  10. Teaching Presentation Skills

    Science.gov (United States)

    Baker, William H.; Thompson, Michael P.

    2004-01-01

    Effective teaching of presentation skills focuses on the most important element of the presentation--the message itself. Some instructors place the heaviest emphasis on the messenger (the presenter) and focus their presentation feedback on all the presenter is doing wrong--saying "um," gesturing awkwardly, and so forth. When students receive this…

  11. Hydrogeology of the 200 Areas low-level burial grounds: An interim report: Volume 2, Appendixes

    Energy Technology Data Exchange (ETDEWEB)

    Last, G.V.; Bjornstad, B.N.; Bergeron, M.P.; Wallace, D.W.; Newcomer, D.R.; Schramke, J.A.; Chamness, M.A.; Cline, C.S.; Airhart, S.P.; Wilbur, J.S.

    1989-01-01

    This report presents information derived form the installation of 35 ground-water monitoring wells around six low-level radioactive/hazardous waste burial grounds located in the 200 Areas of the Hanford Site in southeastern Washington State. This information was collected between May 20, 1987 and August 1, 1988. The contents of this report have been divided into two volumes. Volume 1 contains the main text. This Volume contains the appendixes, including data and supporting information that verify content and results found in the main text.

  12. Cardiovascular simulator improvement: pressure versus volume loop assessment.

    Science.gov (United States)

    Fonseca, Jeison; Andrade, Aron; Nicolosi, Denys E C; Biscegli, José F; Leme, Juliana; Legendre, Daniel; Bock, Eduardo; Lucchi, Julio Cesar

    2011-05-01

    This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made.

  13. Delineation of Supraclavicular Target Volumes in Breast Cancer Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Lindsay C. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Diehn, Felix E. [Department of Radiology, Mayo Clinic, Rochester, Minnesota (United States); Boughey, Judy C. [Department of Surgery, Mayo Clinic, Rochester, Minnesota (United States); Childs, Stephanie K.; Park, Sean S.; Yan, Elizabeth S.; Petersen, Ivy A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Mutter, Robert W., E-mail: mutter.robert@mayo.edu [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States)

    2015-07-01

    Purpose: To map the location of gross supraclavicular metastases in patients with breast cancer, in order to determine areas at highest risk of harboring subclinical disease. Methods and Materials: Patients with axial imaging of gross supraclavicular disease were identified from an institutional breast cancer registry. Locations of the metastatic lymph nodes were transferred onto representative axial computed tomography images of the supraclavicular region and compared with the Radiation Therapy Oncology Group (RTOG) breast cancer atlas for radiation therapy planning. Results: Sixty-two patients with 161 supraclavicular nodal metastases were eligible for study inclusion. At the time of diagnosis, 117 nodal metastases were present in 44 patients. Forty-four nodal metastases in 18 patients were detected at disease recurrence, 4 of whom had received prior radiation to the supraclavicular fossa. Of the 161 nodal metastases, 95 (59%) were within the RTOG consensus volume, 4 nodal metastases (2%) in 3 patients were marginally within the volume, and 62 nodal metastases (39%) in 30 patients were outside the volume. Supraclavicular disease outside the RTOG consensus volume was located in 3 regions: at the level of the cricoid and thyroid cartilage (superior to the RTOG volume), in the posterolateral supraclavicular fossa (posterolateral to the RTOG volume), and in the lateral low supraclavicular fossa (lateral to the RTOG volume). Only women with multiple supraclavicular metastases had nodal disease that extended superiorly to the level of the thyroid cartilage. Conclusions: For women with risk of harboring subclinical supraclavicular disease warranting the addition of supraclavicular radiation, coverage of the posterior triangle and the lateral low supraclavicular region should be considered. For women with known supraclavicular disease, extension of neck coverage superior to the cricoid cartilage may be warranted.

  14. Conjunction Assessment Screening Volume Sizing and Event Filtering in Light of Natural Conjunction Event Development Behaviors

    Science.gov (United States)

    Hejduk, M. D.; Pachura, D. A.

    2017-01-01

    Conjunction Assessment screening volumes used in the protection of NASA satellites are constructed as geometric volumes about these satellites, of a size expected to capture a certain percentage of the serious conjunction events by a certain time before closest approach. However, the analyses that established these sizes were grounded on covariance-based projections rather than empirical screening results, did not tailor the volume sizes to ensure operational actionability of those results, and did not consider the adjunct ability to produce data that could provide prevenient assistance for maneuver planning. The present study effort seeks to reconsider these questions based on a six-month dataset of empirical screening results using an extremely large screening volume. The results, pursued here for a highly-populated orbit regime near 700 km altitude, identify theoretical limits of screening volume performance, explore volume configuration to facilitate both maneuver remediation planning as well as basic asset protection, and recommend sizing principles that maximize volume performance while minimizing the capture of "chaff" conjunctions that are unlikely ever to become serious events.

  15. Putamen volume correlates with obsessive compulsive characteristics in healthy population.

    Science.gov (United States)

    Kubota, Yasutaka; Sato, Wataru; Kochiyama, Takanori; Uono, Shota; Yoshimura, Sayaka; Sawada, Reiko; Sakihama, Morimitsu; Toichi, Motomi

    2016-03-30

    Obsessions and compulsions (OCs) are frequent in healthy subjects; however neural backgrounds of the subclinical OCs were largely unknown. Results from recent studies suggested involvement of the putamen in the OC traits. To investigate this issue, 49 healthy subjects were assessed using structural magnetic resonance imaging (MRI) and the Maudsley Obsessive Compulsive Inventory (MOCI). Anatomical delineation on MRI yielded the global volume and local shape of the putamen. Other striatal structures (the caudate nucleus and globus pallidus) were also examined for exploratory purpose. The relationship between volume/shape of each structures and MOCI measure was analyzed, with sex, age, state anxiety, trait anxiety, and full-scale Intelligence Quotient regressed out. The volume analysis revealed a positive relationship between the MOCI total score and the bilateral putamen volumes. The shape analysis demonstrated associations between the higher MOCI total score and hypertrophy of the anterior putamen in both hemispheres. The present study firstly revealed that the volume changes of the putamen correlated with the manifestation of subclinical OC traits. The dysfunctional cortico-anterior striatum networks seemed to be one of the neuronal subsystems underlying the subclinical OC traits.

  16. Quantifying Snow Volume Uncertainty from Repeat Terrestrial Laser Scanning Observations

    Science.gov (United States)

    Gadomski, P. J.; Hartzell, P. J.; Finnegan, D. C.; Glennie, C. L.; Deems, J. S.

    2014-12-01

    Terrestrial laser scanning (TLS) systems are capable of providing rapid, high density, 3D topographic measurements of snow surfaces from increasing standoff distances. By differencing snow surface with snow free measurements within a common scene, snow depths and volumes can be estimated. These data can support operational water management decision-making when combined with measured or modeled snow densities to estimate basin water content, evaluate in-situ data, or drive operational hydrologic models. In addition, change maps from differential TLS scans can also be used to support avalanche control operations to quantify loading patterns for both pre-control planning and post-control assessment. However, while methods for computing volume from TLS point cloud data are well documented, a rigorous quantification of the volumetric uncertainty has yet to be presented. Using repeat TLS data collected at the Arapahoe Basin Ski Area in Summit County, Colorado, we demonstrate the propagation of TLS point measurement and cloud registration uncertainties into 3D covariance matrices at the point level. The point covariances are then propagated through a volume computation to arrive at a single volume uncertainty value. Results from two volume computation methods are compared and the influence of data voids produced by occlusions examined.

  17. High lung volume increases stress failure in pulmonary capillaries

    Science.gov (United States)

    Fu, Z.; Costello, M. L.; Tsukimoto, K.; Prediletto, R.; Elliott, A. R.; Mathieu-Costello, O.; West, J. B.

    1992-01-01

    We previously showed that when pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to test whether stress failure occurred more frequently at high than at low lung volumes for the same Ptm. Lungs of anesthetized rabbits were inflated to a transpulmonary pressure of 20 cmH2O, perfused with autologous blood at 32.5 or 2.5 cmH2O Ptm, and fixed by intravascular perfusion. Samples were examined by both transmission and scanning electron microscopy. The results were compared with those of a previous study in which the lung was inflated to a transpulmonary pressure of 5 cmH2O. There was a large increase in the frequency of stress failure of the capillary walls at the higher lung volume. For example, at 32.5 cmH2O Ptm, the number of endothelial breaks per millimeter cell lining was 7.1 +/- 2.2 at the high lung volume compared with 0.7 +/- 0.4 at the low lung volume. The corresponding values for epithelium were 8.5 +/- 1.6 and 0.9 +/- 0.6. Both differences were significant (P less than 0.05). At 52.5 cmH2O Ptm, the results for endothelium were 20.7 +/- 7.6 (high volume) and 7.1 +/- 2.1 (low volume), and the corresponding results for epithelium were 32.8 +/- 11.9 and 11.4 +/- 3.7. At 32.5 cmH2O Ptm, the thickness of the blood-gas barrier was greater at the higher lung volume, consistent with the development of more interstitial edema. Ballooning of the epithelium caused by accumulation of edema fluid between the epithelial cell and its basement membrane was seen at 32.5 and 52.5 cmH2O Ptm. At high lung volume, the breaks tended to be narrower and fewer were oriented perpendicular to the axis of the pulmonary capillaries than at low lung volumes. Transmission and scanning electron microscopy measurements agreed well. Our findings provide a physiological

  18. Statistics of extreme objects in the Juropa Hubble Volume simulation

    CERN Document Server

    Watson, W A; Diego, J M; Gottlöber, S; Knebe, A; Martínez-González, E; Yepes, G

    2013-01-01

    We present the first results from the JUropa huBbLE volumE (Jubilee) project, based on the output from a large N-body, dark matter-only cosmological simulation with a volume of V=(6Gpc/h)^3, containing 6000^3 particles, performed within the concordance Lambda-CDM cosmological model. The simulation volume is sufficient to probe extremely large length scales in the universe, whilst at the same time the particle count is high enough so that dark matter haloes down to 1.5x10^12 M_sun/h can be resolved. At z = 0 we identify over 400 million haloes, and the first haloes in the simulation form at z = 11. We present an all-sky map of the Integrated Sachs Wolfe signal calculated from the gravitational potential in the box between z = 0-1.4. The cluster mass function is derived using three different halofinders and compared to fitting functions in the literature, with results being consistent with previous studies across most of the mass-range of the simulation. We compare simulated clusters of maximal mass across reds...

  19. GIRAFFE test results summary

    Energy Technology Data Exchange (ETDEWEB)

    Yokobori, S.; Arai, K.; Oikawa, H. [Toshiba Corporation, Kawasaki (Japan)

    1996-03-01

    A passive system can provide engineered safety features enhancing safety system reliability and plant simplicity. Toshiba has conducted the test Program to demonstrate the feasibility of the SBWR passive safety system using a full-height, integral system test facility GIRAFFE. The test facility GIRAFFE models the SBWR in full height to correctly present the gravity driving head forces with a 1/400 volume scale. The GIRAFFE test Program includes the certification tests of the passive containment cooling system (PCCS) to remove the post-accident decay heat and the gravity driven cooling system (GDCS) to replenish the reactor coolant inventory during a LOCA. The test results have confirmed the PCCS and GDCS design and in addition, have demonstrated the operation of the pCCS with the presence of a lighter-than-steam noncondensable as well as with the presence of a heavier-than-steam, noncondensable. The GIRAFFE test Program has also provided the database to qualify a best estimate thermal-hydraulic computer code TRAC. The post test analysis results have shown that TRAC can accurately predict the PCCS heat removal Performance and the containment pressure response to a LOCA. This paper summarizes the GIRAFFE test results to investigate post-LOCA PCCS heat removal performance and post-test analysis using TRAC.

  20. Bad (Re)Presentations

    CERN Multimedia

    Computer Security Team

    2013-01-01

    This time, we would like to address copyright violations (again) - but with a twist. While previous articles focussed on “Music, videos and the risk for CERN” or on software licences, the focus is now on using photos, music and images “found” on the Web for presentations, publications and web pages…   Just recently, a video produced for CERN and published on YouTube and Facebook used background music from a contemporary popular artist. However, the people responsible failed to obtain the appropriate permission to actually use that music. They thought that having bought it on iTunes was sufficient. But it was not: “buying” means you have the right to listen, but not the right for further distribution or re-publication. As a result, the videos were pulled from YouTube and Facebook. Similarly, how many of us integrate graphics and images “found” on the Web into our presentations?  How many of us...