WorldWideScience

Sample records for volume blood flow

  1. Influence of Gravity on Blood Volume and Flow Distribution

    Science.gov (United States)

    Pendergast, D.; Olszowka, A.; Bednarczyk, E.; Shykoff, B.; Farhi, L.

    1999-01-01

    In our previous experiments during NASA Shuttle flights SLS 1 and 2 (9-15 days) and EUROMIR flights (30-90 days) we observed that pulmonary blood flow (cardiac output) was elevated initially, and surprisingly remained elevated for the duration of the flights. Stroke volume increased initially and then decreased, but was still above 1 Gz values. As venous return was constant, the changes in SV were secondary to modulation of heart rate. Mean blood pressure was at or slightly below 1 Gz levels in space, indicating a decrease in total peripheral resistance. It has been suggested that plasma volume is reduced in space, however cardiac output/venous return do not return to 1 Gz levels over the duration of flight. In spite of the increased cardiac output, central venous pressure was not elevated in space. These data suggest that there is a change in the basic relationship between cardiac output and central venous pressure, a persistent "hyperperfusion" and a re-distribution of blood flow and volume during space flight. Increased pulmonary blood flow has been reported to increase diffusing capacity in space, presumably due to the improved homogeneity of ventilation and perfusion. Other studies have suggested that ventilation may be independent of gravity, and perfusion may not be gravity- dependent. No data for the distribution of pulmonary blood volume were available for flight or simulated microgravity. Recent studies have suggested that the pulmonary vascular tree is influenced by sympathetic tone in a manner similar to that of the systemic system. This implies that the pulmonary circulation is dilated during microgravity and that the distribution of blood flow and volume may be influenced more by vascular control than by gravity. The cerebral circulation is influenced by sympathetic tone similarly to that of the systemic and pulmonary circulations; however its effects are modulated by cerebral autoregulation. Thus it is difficult to predict if cerebral perfusion is

  2. Resistance exercise with different volumes: blood pressure response and forearm blood flow in the hypertensive elderly

    Directory of Open Access Journals (Sweden)

    Brito AF

    2014-12-01

    Full Text Available Aline de Freitas Brito,1 Caio Victor Coutinho de Oliveira,2 Maria do Socorro Brasileiro-Santos,1 Amilton da Cruz Santos1 1Physical Education Department, 2Research Laboratory for Physical Training Applied to Performance and Health, Federal University of Paraíba, João Pessoa, Brazil Background: The purpose of this study was to evaluate the effect of two sessions of resistance exercise with different volumes on post-exercise hypotension, forearm blood flow, and forearm vascular resistance in hypertensive elderly subjects.Methods: The study was conducted with ten hypertensive elderly (65±3 years, 28.7±3 kg/m2 subjected to three experimental sessions, ie, a control session, exercise with a set (S1, and exercise with three sets (S3. For each session, the subjects were evaluated before and after intervention. In the pre-intervention period, blood pressure, forearm blood flow, and forearm vascular resistance were measured after 10 minutes of rest in the supine position. Thereafter, the subjects were taken to the gym to perform their exercise sessions or remained at rest during the same time period. Both S1 and S3 comprised a set of ten repetitions of ten exercises, with an interval of 90 seconds between exercises. Subsequently, the measurements were again performed at 10, 30, 50, 70, and 90 minutes of recovery (post-intervention in the supine position.Results: Post-exercise hypotension was greater in S3 than in S1 (systolic blood pressure, −26.5±4.2 mmHg versus −17.9±4.7 mmHg; diastolic blood pressure, −13.8±4.9 mmHg versus −7.7±5 mmHg, P<0.05. Similarly, forearm blood flow and forearm vascular resistance changed significantly in both sessions with an increase and decrease, respectively, that was more evident in S3 than in S1 (P<0.05.Conclusion: Resistance exercises with higher volume were more effective in causing post-exercise hypotension, being accompanied by an increase in forearm blood flow and a reduction of forearm vascular

  3. Reflectometric mapping of microregional blood flow and blood volume in the brain cortex.

    Science.gov (United States)

    Eke, A

    1982-01-01

    A reflectometric indicator-dilution method has been developed for mapping the parenchymal minute volume flow and blood content over tiny superficial areas of the brain cortex at 625 or 2500 locations, respectively. About 0.4 ml dextran-saline solution was used as nondiffusible indicator and injected into the feline cerebral circulation for each measurement. The subsequent cerebrocortical transit of the hemodiluted bolus was detected as a temporary change in the tissue optical density [OD(t)] and interpreted as indicator dilution, C(t). This gave the data necessary to calculate the microregional blood volume (mrCBV), mean transit time of the bolus (mrMTT), and the microregional blood flow (mrCBF = mrCBV/mrMTT). A two-dimensional record of the OD(t) function was made on Kodak SO 115 film by 16-mm cinematography, as a reflectometric tool, over an exposed area of the brain cortex during the bolus perfusion. Later, the microregional OD(t) functions were retrieved for analysis in a square array from the developed film by computer-controlled, frame-by-frame scanning densitometry. Maps of mrCBF, mrCBV, and mrMTT were presented as square arrays of gray-scaled pixels. The maximal spatial and temporal resolution of the method was 0.015 mm2 (mrCBF), 0.004 mm2 (mrCBV), 6 maps/min (mrCBF), and 600 maps/min (mrCBV).

  4. Fixed volume particle trace emission for the analysis of left atrial blood flow using 4D Flow MRI.

    Science.gov (United States)

    Gaeta, Stephen; Dyverfeldt, Petter; Eriksson, Jonatan; Carlhäll, Carl-Johan; Ebbers, Tino; Bolger, Ann F

    2017-12-05

    4D Flow MRI has been used to quantify normal and deranged left ventricular blood flow characteristics on the basis of functionally distinct flow components. However, the application of this technique to the atria is challenging due to the presence of continuous inflow. This continuous inflow necessitates plane-based emission of particle traces from the inlet veins, leading to particles that represents different amounts of blood, and related quantification errors. The purpose of this study was to develop a novel fixed-volume approach for particle tracing and employ this method to develop quantitative analysis of 4D blood flow characteristics in the left atrium. 4D Flow MRI data were acquired during free-breathing using a navigator-gated gradient-echo sequence in three volunteers at 1.5T. Fixed-volume particle traces emitted from the pulmonary veins were used to visualize left atrial blood flow and to quantitatively separate the flow into two functionally distinct flow components: Direct flow=particle traces that enter and leave the atrium in one heartbeat, Retained flow=particle traces that enter the atrium and remains there for one cardiac cycle. Flow visualization based on fixed-volume traces revealed that, beginning in early ventricular systole, flow enters the atrium and engages with residual blood volume to form a vortex. In early diastole during early ventricular filling, the organized vortical flow is extinguished, followed by formation of a second transient atrial vortex. Finally, in late diastole during atrial contraction, a second acceleration of blood into the ventricle is seen. The direct and retained left atrial flow components were between 44 and 57% and 43-56% of the stroke volume, respectively. In conclusion, fixed-volume particle tracing permits separation of left atrial blood flow into different components based on the transit of blood through the atrium. Copyright © 2017. Published by Elsevier Inc.

  5. Quantitative evaluation of myocardial function by a volume-normalized map generated from relative blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Fukami, Tadanori [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Sato, Hidenori [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Wu, Jin [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Lwin, Thet-Thet- [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Yuasa, Tetsuya [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Kawano, Satoru [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Iida, Keiji [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Akatsuka, Takao [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Hontani, Hidekata [Department of Computer Science and Engineering, Nagoya Institute of Technology, Aichi 466-8555 (Japan); Takeda, Tohoru [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Tamura, Masao [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Yokota, Hiroshi [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan)

    2007-07-21

    Our study aimed to quantitatively evaluate blood flow in the left ventricle (LV) of apical hypertrophic cardiomyopathy (APH) by combining wall thickness obtained from cardiac magnetic resonance imaging (MRI) and myocardial perfusion from single-photon emission computed tomography (SPECT). In this study, we considered paired MRI and myocardial perfusion SPECT from ten patients with APH and ten normals. Myocardial walls were detected using a level set method, and blood flow per unit myocardial volume was calculated using 3D surface-based registration between the MRI and SPECT images. We defined relative blood flow based on the maximum in the whole myocardial region. Accuracies of wall detection and registration were around 2.50 mm and 2.95 mm, respectively. We finally created a bull's-eye map to evaluate wall thickness, blood flow (cardiac perfusion) and blood flow per unit myocardial volume. In patients with APH, their wall thicknesses were over 10 mm. Decreased blood flow per unit myocardial volume was detected in the cardiac apex by calculation using wall thickness from MRI and blood flow from SPECT. The relative unit blood flow of the APH group was 1/7 times that of the normals in the apex. This normalization by myocardial volume distinguishes cases of APH whose SPECT images resemble the distributions of normal cases.

  6. [Changes of blood flow volume in dog's mental artery after mandible osteocompression].

    Science.gov (United States)

    Huang, Xiao-Feng; Zeng, Xiang-Long

    2010-12-01

    To observe the changes of blood flow volume in mental artery of dog before and after osteocompression. 16 adult dogs were selected and the osteocompressors were fixed on the right buccal side of the mandible. The osteocompressor was used to compress the mandible 1.0 mm per 3 days for totally 15 days. On the 1st, 15th, 45th and 90th day after osteocompression, the 4 MHz prober of color Doppler flow imaging machine was put on the surface of the mucosa below which there was the mental artery. The color Doppler flow imaging was used to measure the blood flow volume in the mental artery of both experimental and control sides. 1) The blood flow value in the mental artery was the lowest on the 15th day after osteocompression, however there was not significantly different before and after osteocompression. 2) Compared with the control, the blood flow value of the mental artery on the 1st day after experiment was significantly decreased. 3) Compared with the data before experiment, the deduction of the blood flow values between experimental side and control on the 1st, 15th and 45th day after osteocompression had significant differences. On the 90th day, the deduction of the blood flow value was similar to normal. The osteocompression influences blood flow volume in mental artery temporarily, however, the influence is reversible and can be recovered by times after osteocompression.

  7. Blood flow, volume and arterio-venous passages in induced mammary tumours of the rat.

    Science.gov (United States)

    Hultborn, Ragnar

    2018-03-01

    To study blood flow, vascular volume and arterio-venous passages in induced mammary tumours of the rat to characterize parameters possibly responsible for tumour hyponutrition. Dimethylbenzanthracene-induced mammary tumours in Sprague-Dawley rats were studied. Regional blood flow was studied by use of the radioactive microsphere tracer technique using 141Cerium-labelled 15μm spheres coinjected into the left cardiac ventricle with 125Iodine-labelled 25μm spheres. Blood volume was studied by use of 125Iodine- or 99mTechnetium-labelled human serum albumin, the latter allowing autoradiography of tumour sections for visualization of flow and volume. Twenty-seven rats with 170 tumours had a mean tumour blood flow of 48 and 67mL×min-1×100g-1 using 15 and 25μm sphere data, respectively, indicating a significant passage through vessels between 15 and 25μm. The lungs showed a "nominal bronchial" blood flow of 260 and 135mL×min-1×100g-1 for the 15 and 25μm spheres, respectively, indicating pulmonary trapping, particularly of small spheres passing the systemic circulation in vessels larger than 15μm. There was a positive correlation between the total tumour blood flow within individual rats and trapped spheres of both dimensions in the lungs, indicating shunts also larger than 25μm. Normal tissues disclosed only small differences in regional blood flow as measured by the two spheres. Blood volume was studied in 20 rats with 120 tumours, with a vascular volume of 3.6mL×100g-1 representing a blood turnover >15 times/min. Blood volume co-localized with perfusion as seen in autoradiographs. In induced rat mammary tumours, a high fraction of blood, 28%, passes arterio-venous vessels between 15 and 25μm and there also exist passages >25μm. These findings indicate that the functional capacity of the tumour vascular bed might be impaired, adding to the abnormal microenvironment of tumours. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2002-09-15

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  9. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  10. Cerebral blood volume and blood flow responses to hyperventilation in brain tumors during isoflurane or propofol anesthesia.

    Science.gov (United States)

    Cenic, Aleksa; Craen, Rosemary A; Lee, Ting-Yim; Gelb, Adrian W

    2002-03-01

    Using computerized tomography, we measured absolute cerebral blood flow (CBF) and cerebral blood volume (CBV) in tumor, peri-tumor, and contralateral normal regions, at normocapnia and hypocapnia, in 16 rabbits with brain tumors (VX2 carcinoma), under isoflurane or propofol anesthesia. In both anesthetic groups, CBV and CBF were highest in the tumor region and lowest in the contralateral normal tissue. For isoflurane, a significant decrease in both CBV and CBF was observed in all tissue regions with hyperventilation (P hyperventilation for all regions (P > 0.10). In addition, there were no differences between CBV values for isoflurane at hypocapnia when compared with CBV values for propofol at normo- or hypocapnia (P > 0.34 and P > 0.35, respectively, in the tumor regions). Our results indicate that propofol increases cerebral vascular tone in both neoplastic and normal tissue vessels compared with isoflurane. CBV and CBF during normocapnia were significantly greater in all regions (tumor, peri-tumor, and contralateral normal tissue) with isoflurane than with propofol. CBV and CBF remained responsive to hyperventilation only with isoflurane. In rabbits with brain tumors, brain blood flow and volume were significantly larger in all regions (tumor, peri-tumor, and contralateral normal tissue) with isoflurane than with propofol during normocapnia, and remained responsive to a reduction in PaCO(2). Consequently, during hypocapnia, brain blood flow and volume values with isoflurane were similar to values with propofol.

  11. Validation of a continuous penile blood-flow measurement by pulse-volume-plethysmography.

    Science.gov (United States)

    Lavoisier, P; Barbe, R; Gally, M

    2002-04-01

    Today, in the assessment of cavernous artery blood-flow, the most commonly used technique is Doppler ultrasound velocimetry (continuous, pulsed, color-coded or power), which is often considered as the gold standard. Plethysmographic techniques and radioactive tracers have been widely used for the assessment of global penis flow variations but are not adequate for continuous blood-flow measurement. A new pulse-volume plethysmographic (PVP) device using a water-filled penile cuff was employed to assess continuous blood-flow measurement in the penis. Simultaneously Doppler velocity was recorded and served as a gold standard. A penile water-cuff is connected through a pressure tube to a three-way tap. The pulse-volume changes in the penile water-cuff are measured by means of a latex membrane placed over one of the three-way taps. The displacements of the latex are recorded by a photoplethysmograph. The third tap is connected to a 5 l perfusion bag placed 30 cm above the penis so as to maintain constant pressure in the whole device whatever the penis volume. Twenty-four volunteers were tested. The Doppler velocity signal and pulse volume of cavernous arteries were measured simultaneously after PGE1 intra-cavernous injection. Blood-flow variations were induced by increasing penis artery compression with a second penile water-cuff used as a tourniquet fitted onto the penis root, and the pressure of which could be modified by a water-filled syringe. The amplitude of the plethysmographic pulse-volume signal and the area under the Doppler velocity signal were correlated. The inter-patient (n=24) correlation ranged from 0.455 to 0.904, with a mean correlation of 0.704 and P<0.0001. PVP measurement by a water-filled cuff was validated by ultrasound velocimetry. This new continuous, non-invasive and easy-to-use technique enables physiological and physiopathological flow-measurement during sleep, under visual sexual stimulation (VSS), or following artificial erection

  12. Impedance cardiography: Pulsatile blood flow and the biophysical and electrodynamic basis for the stroke volume equations

    Directory of Open Access Journals (Sweden)

    Donald P Bernstein

    2010-01-01

    Full Text Available Impedance cardiography (ICG is a branch of bioimpedance pimarily concerned with the determination of left ventricular stroke volume (SV. As implemented, using the transthoracic approach, the technique involves applying a current field longitudinally across a segment of thorax by means of a constant magnitude, high frequency, low amplitude alternating current (AC. By Ohm's Law, the voltage difference measured within the current field is proportional to the electrical impedance Z (Ω. Without ventilatory or cardiac activity, Z is known as the transthoracic, static base impedance Z0. Upon ventricular ejection, a characteristic time dependent cardiac-synchronous pulsatile impedance change is obtained, ΔZ(t, which, when placed electrically in parallel with Z0, constitutes the time-variable total transthoracic impedance Z(t. ΔZ(t represents a dual-element composite waveform, which comprises both the radially-oriented volumetric expansion of and axially-directed forward blood flow within both great thoracic arteries. In its majority, however, ΔZ(t is known to primarily emanate from the ascending aorta. Conceptually, commonly implemented methods assume a volumetric origin for the peak systolic upslope of ΔZ(t, (i.e. dZ/dtmax, with the presumed units of Ω·s-1. A recently introduced method assumes the rapid ejection of forward flowing blood in earliest systole causes significant changes in the velocity-induced blood resistivity variation (Δρb(t, Ωcm·s-1, and it is the peak rate of change of the blood resistivity variation dρb(t/dtmax (Ωcm·s-2 that is the origin of dZ/dtmax. As a consequence of dZ/dtmax peaking in the time domain of peak aortic blood acceleration, dv/dtmax (cm·s-2, it is suggested that dZ/dtmax is an ohmic mean acceleration analog (Ω·s-2 and not a mean flow or velocity surrogate as generally assumed. As conceptualized, the normalized value, dZ/dtmax/Z0, is a dimensionless ohmic mean acceleration equivalent (s-2

  13. Optical oximetry of volume-oscillating vascular compartments: contributions from oscillatory blood flow

    Science.gov (United States)

    Kainerstorfer, Jana M.; Sassaroli, Angelo; Fantini, Sergio

    2016-10-01

    We present a quantitative analysis of dynamic diffuse optical measurements to obtain oxygen saturation of hemoglobin in volume oscillating compartments. We used a phasor representation of oscillatory hemodynamics at the heart rate and respiration frequency to separate the oscillations of tissue concentrations of oxyhemoglobin (O) and deoxyhemoglobin (D) into components due to blood volume (subscript V) and blood flow (subscript F): O=OV+OF, D=DV+DF. This is achieved by setting the phase angle Arg(OF)-Arg(O), which can be estimated by a hemodynamic model that we recently developed. We found this angle to be -72 deg for the cardiac pulsation at 1 Hz, and -7 deg for paced breathing at 0.1 Hz. Setting this angle, we can obtain the oxygen saturation of hemoglobin of the volume-oscillating vascular compartment, SV=|OV|/(|OV|+|DV|). We demonstrate this approach with cerebral near-infrared spectroscopy measurements on healthy volunteers at rest (n=4) and during 0.1 Hz paced breathing (n=3) with a 24-channel system. Rest data at the cardiac frequency were used to calculate the arterial saturation, S(a); over all subjects and channels, we found ==0.96±0.02. In the case of paced breathing, we found =0.66±0.14, which reflects venous-dominated hemodynamics at the respiratory frequency.

  14. Noninvasive MRI measurement of the absolute cerebral blood volume-cerebral blood flow relationship during visual stimulation in healthy humans.

    Science.gov (United States)

    Ciris, Pelin Aksit; Qiu, Maolin; Constable, R Todd

    2014-09-01

    The relationship between cerebral blood volume (CBV) and cerebral blood flow (CBF) underlies blood oxygenation level-dependent functional MRI signal. This study investigates the potential for improved characterization of the CBV-CBF relationship in humans, and examines sex effects as well as spatial variations in the CBV-CBF relationship. Healthy subjects were imaged noninvasively at rest and during visual stimulation, constituting the first MRI measurement of the absolute CBV-CBF relationship in humans with complete coverage of the functional areas of interest. CBV and CBF estimates were consistent with the literature, and their relationship varied both spatially and with sex. In a region of interest with stimulus-induced activation in CBV and CBF at a significance level of the P < 0.05, a power function fit resulted in CBV = 2.1 CBF(0.32) across all subjects, CBV = 0.8 CBF(0.51) in females and CBV = 4.4 CBF(0.15) in males. Exponents decreased in both sexes as ROIs were expanded to include less significantly activated regions. Consideration for potential sex-related differences, as well as regional variations under a range of physiological states, may reconcile some of the variation across literature and advance our understanding of the underlying cerebrovascular physiology. Copyright © 2013 Wiley Periodicals, Inc.

  15. Pelvic Blood Flow Predicts Fibroid Volume and Embolic Required for Uterine Fibroid Embolization: A Pilot Study With 4D Flow MR Angiography.

    Science.gov (United States)

    Malone, Christopher D; Banerjee, Arjun; Alley, Marcus T; Vasanawala, Shreyas S; Roberts, Anne C; Hsiao, Albert

    2018-01-01

    We report here an initial experience using 4D flow MRI in pelvic imaging-specifically, in imaging uterine fibroids. We hypothesized that blood flow might correlate with fibroid volume and that quantifying blood flow might help to predict the amount of embolic required to achieve stasis at subsequent uterine fibroid embolization (UFE). Thirty-three patients with uterine fibroids and seven control subjects underwent pelvic MRI with 4D flow imaging. Of the patients with fibroids, 10 underwent 4D flow imaging before UFE and seven after UFE; in the remaining 16 patients with fibroids, UFE had yet to be performed. Four-dimensional flow measurements were performed using Arterys CV Flow. The flow fraction of the internal iliac artery was expressed as the ratio of internal iliac artery flow to external iliac artery flow and was compared between groups. The flow ratios between the internal iliac arteries on each side were calculated. Fibroid volume versus internal iliac flow fraction, embolic volume versus internal iliac flow fraction, and embolic volume ratio between sides versus the ratio of internal iliac artery flows between sides were compared. The mean internal iliac flow fraction was significantly higher in the 26 patients who underwent imaging before UFE (mean ± standard error, 0.78 ± 0.06) than in the seven patients who underwent imaging after UFE (0.48 ± 0.07, p flow fraction correlated well with fibroid volumes before UFE (r = 0.7754, p flow (r = 0.6776, p = 0.03). Internal iliac flow measured by 4D flow MRI correlates with fibroid volume and is predictive of the ratio of embolic required to achieve stasis on each side at subsequent UFE and may be useful for preprocedural evaluation of patients with uterine fibroids.

  16. Changes of Blood Flow Volume in the Superior Mesenteric Artery and Brachial Artery with Abdominal Thermal Stimulation

    Directory of Open Access Journals (Sweden)

    Shin Takayama

    2011-01-01

    Full Text Available In traditional Chinese medicine, moxibustion is a local thermal therapy that is used for several conditions. Quantifying the effects of moxibustion therapy has been difficult because the treatment temperature depends on the physician's experience, and the temperature distribution in the target area is not uniform. This prospective observational study aims to quantify the effect of local thermal stimulation to the abdomen. We developed a heat transfer control device (HTCD for local thermal stimulation. Twenty-four healthy subjects were enrolled and they underwent abdominal thermal stimulation to the para-umbilical region with the device for 20 min. Blood flow volume in the superior mesenteric artery (SMA and brachial artery (BA, the heart rate and the blood pressure were measured at rest, 15 min after starting thermal stimulation and 10, 20, 30 and 40 min after completing thermal stimulation. Blood flow parameters were measured by high-resolution ultrasound. In the SMA, blood flow volume was significantly increased during thermal stimulation (, as well as at 10 min ( and 20 min ( after stimulation. In the BA, blood flow volume decreased at 40 min after stimulation (. In conclusion we could quantify the effect of local thermal stimulation with an HTCD and high-resolution ultrasound. Thermal stimulation of the para-umbilical region increased blood flow in the SMA 20 min after stimulation in healthy subjects.

  17. Radionuclide assessment of peripheral hemodynamics: a new technique for measurement of forearm blood volume and flow

    Energy Technology Data Exchange (ETDEWEB)

    Todo, Y.; Tanimoto, M.; Yamamoto, T.; Iwasaki, T.

    1986-02-01

    A new peripheral hemodynamic measurement system using /sup 99m/Tc-labeled red blood cells has been developed. This method was carried out on 22 normal subjects, 29 with coronary artery disease, and two with dilated cardiomyopathy. Peripheral hemodynamic indices obtained from this method included forearm blood volume (FBV), venous capacity (FVC), venous capacity index (VCI), blood flow (FBF), and vascular resistance (FVR), and were compared with the central hemodynamic parameters of left ventricular filling pressure (LVFP), cardiac output (CO), and total systemic vascular resistance (TSVR) obtained with an invasive technique. The normal values were FBV 8.54 +/- 2.04 ml/100 ml; FVC 4.54 +/- 1.23 ml/100 ml; VCI 65.5 +/- 3.8%; FBF 4.26 +/- 0.56 ml/100 ml/min; and FVR 20.9 +/- 4.4 mmHg/ml/100 ml/min. These values were in good agreement with the values reported using conventional plethysmography. The 16 patients with congestive heart failure (NYHA Class II or III) showed significantly lower FBV, FVC, and FBF values and significantly higher VCI and FVR values than the healthy subjects. Capacitance vessel parameters (FBV, FVC, and VCI) and LVFP, FBF and CO, and FVR and TSVR each showed significant correlation; reproducibility was also good. The advantages of this method are (a) the detector does not come in contact with the region being measured; (b) it is possible to ascertain the absolute quantity of blood in the tissue; (c) extravasation of the plasma component can be ignored; and (d) data processing is simple.

  18. Cerebral blood flow in temporal lobe epilepsy: a partial volume correction study

    Energy Technology Data Exchange (ETDEWEB)

    Giovacchini, Giampiero [University Milano-Bicocca, Milan (Italy); Bonwetsch, Robert; Theodore, William H. [National Institute of Neurological Diseases and Strokes, Clinical Epilepsy Section, Bethesda, MD (United States); Herscovitch, Peter [National Institutes of Health, PET Department, Clinical Center, Bethesda, MD (United States); Carson, Richard E. [Yale PET Center, New Haven, CT (United States)

    2007-12-15

    Previous studies in temporal lobe epilepsy (TLE) have shown that, owing to brain atrophy, positron emission tomography (PET) can overestimate deficits in measures of cerebral function such as glucose metabolism (CMR{sub glu}) and neuroreceptor binding. The magnitude of this effect on cerebral blood flow (CBF) is unexplored. The aim of this study was to assess CBF deficits in TLE before and after magnetic resonance imaging-based partial volume correction (PVC). Absolute values of CBF for 21 TLE patients and nine controls were computed before and after PVC. In TLE patients, quantitative CMR{sub glu} measurements also were obtained. Before PVC, regional values of CBF were significantly (p<0.05) lower in TLE patients than in controls in all regions, except the fusiform gyrus contralateral to the epileptic focus. After PVC, statistical significance was maintained in only four regions: ipsilateral inferior temporal cortex, bilateral insula and contralateral amygdala. There was no significant difference between patients and controls in CBF asymmetry indices (AIs) in any region before or after PVC. In TLE patients, AIs for CBF were significantly smaller than for CMR{sub glu} in middle and inferior temporal cortex, fusiform gyrus and hippocampus both before and after PVC. A significant positive relationship between disease duration and AIs for CMR{sub glu}, but not CBF, was detected in hippocampus and amygdala, before but not after PVC. PVC should be used for PET CBF measurements in patients with TLE. Reduced blood flow, in contrast to glucose metabolism, is mainly due to structural changes. (orig.)

  19. Absolute cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking: comparison with positron emission tomography values

    DEFF Research Database (Denmark)

    Østergaard, Leif; Smith, D F; Vestergaard-Poulsen, Peter

    1998-01-01

    blood volume (CBV) estimates obtained using this normalization constant correlated well with values obtained by O-15 labeled carbonmonooxide (C15O) PET. However, PET CBV values were approximately 2.5 times larger than absolute MRI CBV values, supporting the hypothesized sensitivity of MRI to small...

  20. 3D phase contrast MRI: Partial volume correction for robust blood flow quantification in small intracranial vessels.

    Science.gov (United States)

    Bouillot, Pierre; Delattre, Bénédicte M A; Brina, Olivier; Ouared, Rafik; Farhat, Mohamed; Chnafa, Christophe; Steinman, David A; Lovblad, Karl-Olof; Pereira, Vitor M; Vargas, Maria I

    2018-01-01

    Recent advances in 3D-PCMRI (phase contrast MRI) sequences allow for measuring the complex hemodynamics in cerebral arteries. However, the small size of these vessels vs spatial resolution can lead to non-negligible partial volume artifacts, which must be taken into account when computing blood flow rates. For this purpose, we combined the velocity information provided by 3D-PCMRI with vessel geometry measured with 3DTOF (time of flight MRI) or 3DRA (3D rotational angiography) to correct the partial volume effects in flow rate assessments. The proposed methodology was first tested in vitro on cylindrical and patient specific vessels subject to fully controlled pulsatile flows. Both 2D- and 3D-PCMRI measurements using various spatial resolutions ranging from 20 to 1.3 voxels per vessel diameter were analyzed and compared with flowmeter baseline. Second, 3DTOF, 2D- and 3D-PCMRI measurements were performed in vivo on 35 patients harboring internal carotid artery (ICA) aneurysms indicated for endovascular treatments requiring 3DRA imaging. The in vitro 2D- and 3D-PCMRI mean flow rates assessed with partial volume correction showed very low sensitivity to the acquisition resolution above ≈2 voxels per vessel diameter while uncorrected flow rates deviated critically when decreasing the spatial resolution. 3D-PCMRI flow rates measured in vivo in ICA agreed very well with 2D-PCMRI data and a good flow conservation was observed at the C7 bifurcation. Globally, partial volume correction led to 10-15% lower flow rates than uncorrected values as those reported in most of the published studies on intracranial flows. Partial volume correction may improve the accuracy of PCMRI flow rate measurements especially in small vessels such as intracranial arteries. Magn Reson Med 79:129-140, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  1. Effects of totally extraperitoneal (TEP) and Lichtenstein hernia repair on testicular blood flow and volume.

    Science.gov (United States)

    Gürbulak, Esin Kabul; Gürbulak, Bünyamin; Akgün, İsmail Ethem; Özel, Alper; Akan, Deniz; Ömeroğlu, Sinan; Öz, Ayhan; Mihmanlı, Mehmet; Bektaş, Hasan

    2015-11-01

    Laparoscopic totally extraperitoneal hernia repair (TEP) has been compared with the open technique in several studies in terms of technical properties and perioperative outcomes. There are few studies that compare the long-term effects of each technique on testicular structure and function on the side of the hernia repair. The objective of this study is to investigate the effects at 6 months of the TEP and the Lichtenstein technique on testicular volume and arterial flow by the use of Doppler ultrasonography. A total of 148 men with a unilateral hernia were randomized prospectively to undergo TEP or Lichtenstein repair. In both groups, unilateral resistive indices, pulsatile indices of capsular and intratesticular artery flow, and testicular volume (in milliliters) were measured preoperatively and 6 months postoperatively by the use of grayscale and color Doppler ultrasonography (CDUS). The primary outcomes of the study were postoperative findings from history, physical examination, and CDUS measurements at 6 months postoperatively. Demographics, clinical and operative data, CDUS measurements, and recurrence patterns were analyzed. Of 148 procedures, 134 cases consisting of 64 TEP and 70 Lichtenstein repairs were evaluated. Pre- and postoperative CDUS findings, rates of complications, and recurrence in both groups did not show any difference. Operative time was greater with a Lichtenstein repair (36 vs 30 minutes; P = .01). Complications and recurrence rates and effects on testicular perfusion and testicular volume in both laparoscopic and open techniques are similar, whereas the laparoscopic approach has shorter operative time than open hernia repair. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Three-dimensional finite volume modelling of blood flow in simulated angular neck abdominal aortic aneurysm

    Science.gov (United States)

    Algabri, Y. A.; Rookkapan, S.; Chatpun, S.

    2017-09-01

    An abdominal aortic aneurysm (AAA) is considered a deadly cardiovascular disease that defined as a focal dilation of blood artery. The healthy aorta size is between 15 and 24 mm based on gender, bodyweight, and age. When the diameter increased to 30 mm or more, the rupture can occur if it is kept growing or untreated. Moreover, the proximal angular neck of aneurysm is categorized as a significant morphological feature with prime harmful effects on endovascular aneurysm repair (EVAR). Flow pattern in pathological vessel can influence the vascular intervention. The aim of this study is to investigate the blood flow behaviours in angular neck abdominal aortic aneurysm with simulated geometry based on patient’s information using computational fluid dynamics (CFD). The 3D angular neck AAA models have been designed by using SolidWorks Software. Consequently, CFD tools are used for simulating these 3D models of angular neck AAA in ANSYS FLUENT Software. Eventually, based on the results, we summarized that the CFD techniques have shown high performance in explaining and investigating the flow patterns for angular neck abdominal aortic aneurysm.

  3. Relationship between the changes in blood flow and volume in the finger during a Braille character discrimination task.

    Science.gov (United States)

    Murata, J; Murata, S; Soma, M; Nakae, H; Sato, Y; Kogo, H; Umeki, N

    2017-11-01

    We hypothesized that skin blood flow (SBF) of fingers are modulated during concentrated finger perception and that the changes in SBF reflect fluctuations in finger volume (FV). The aim of this study, therefore, was examine the relationship between the changes in SBF and FV during Braille reading. We measured SBF of the finger, cutaneous vascular conductance (CVC), FV, and arterial blood pressure during Braille reading performed under blind conditions in thirty healthy subjects. The subjects were instructed to read a flat plate with raised letters (Braille reading) for 15 seconds using their forefinger, and to touch a blank plate as a control for the Braille discrimination procedure. Arterial blood pressure slightly increased during Braille reading but remained unchanged during the touching of the blank plate. SBF, CVC, and FV were reduced during Braille reading (decreased by -26%, -29%, and -0.3 mL/100 mL respectively). Furthermore, a significant relationship was observed between the changes in SBF and FV (r=.613) during Braille reading. These results suggested that SBF of fingers is modulated during concentrated finger perception, and that the variability of blood flow reflects the response in FV. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    Energy Technology Data Exchange (ETDEWEB)

    McCommis, Kyle S.; Goldstein, Thomas A.; Pilgram, Thomas [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Abendschein, Dana R. [Washington University School of Medicine, Center for Cardiovascular Research, St. Louis, MO (United States); Misselwitz, Bernd [Bayer Schering Pharma AG, Berlin (Germany); Gropler, Robert J. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Center for Cardiovascular Research, St. Louis, MO (United States); Zheng, Jie [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Cardiovascular Imaging Lab, St. Louis, MO (United States)

    2010-08-15

    To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and {sup 99m}Tc-labeled red blood cells were injected to obtain respective gold standards. Microsphere-measured MBF and {sup 99m}Tc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. (orig.)

  5. Development and application of a volume penalization immersed boundary method for the computation of blood flow and shear stresses in cerebral vessels and aneurysms

    NARCIS (Netherlands)

    Mikhal, Julia Olegivna; Geurts, Bernardus J.

    2013-01-01

    A volume-penalizing immersed boundary method is presented for the simulation of laminar incompressible flow inside geometrically complex blood vessels in the human brain. We concentrate on cerebral aneurysms and compute flow in curved brain vessels with and without spherical aneurysm cavities

  6. A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI ☆

    OpenAIRE

    Okell, Thomas W.; Chappell, Michael A.; Jezzard, Peter

    2013-01-01

    Angiographic methods can provide valuable information on vessel morphology and hemodynamics, but are often qualitative in nature, somewhat limiting their ability for comparison across arteries and subjects. In this work we present a method for quantifying absolute blood volume flow rates within large vessels using dynamic angiographic data. First, a kinetic model incorporating relative blood volume, bolus dispersion and signal attenuation is fitted to the data. A self-calibration method is al...

  7. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    Directory of Open Access Journals (Sweden)

    Arheden Håkan

    2011-04-01

    Full Text Available Abstract Background Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Methods Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Results Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Conclusion Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking

  8. Changes in plasma volume, in transcapillary escape rate of albumin and in subcutaneous blood flow during hypoglycaemia in man

    DEFF Research Database (Denmark)

    Hilsted, J; Bonde-Petersen, F; Madsbad, S

    1985-01-01

    and transcapillary escape rate increased significantly during hypoglycaemia. Skin temperature and local subcutaneous adipose tissue blood flow were measured in four different regions. Both tended to decrease during hypoglycaemia and decreased significantly 2 h after hypoglycaemia. There was no correlation between...... changes in the two measurements, suggesting that there is no simple relationship between subcutaneous blood flow and skin temperature during hypoglycaemia....

  9. Quantification of rat retinal and choroidal blood plasma kinetics, volume, and flow in vivo using dynamic contrast optical coherence tomography (Conference Presentation)

    Science.gov (United States)

    Merkle, Conrad W.; Srinivasan, Vivek J.

    2017-02-01

    Blood flow patterns and kinetics in the choriocapillaris are poorly understood owing to a lack of quantitative ophthalmic imaging techniques for studying microvascular flow in the eye. Compared with the proximal retinal vasculature, the more distal choroidal vasculature is relatively more challenging to probe. Magnetic Resonance Imaging and Doppler Ultrasound can assess the retina and choroid, but do not resolve the finer layers or microvasculature. While Optical Coherence Tomography (OCT) angiography produces high-quality choroidal images, attempts at quantification through Doppler-based methods have had mixed success. Here, we use a new technique called Dynamic Contrast OCT (DyC-OCT), which tracks the passage of an intravascular scattering contrast agent, to reveal laminar blood flow patterns in the retina and choroid in vivo. While conceptually similar to fluorescence angiography, DyC-OCT has the substantial benefit of depth resolution, which enables separation of retinal and choroidal microvasculature. The scattering contrast agent enables improved angiography of both macro- and microvasculature in the retina and choroid. Blood plasma transit times are measured in individual vessels, while flow and volume are quantified for each of the microvascular layers. As expected, the choriocapillaris had the highest volume and flow. Blood flow rates were estimated with an average retinal blood flow of 9.1 ± 4.3 μL/min and an average choroidal blood flow of 40 ± 18.3 μL/min in the rat eye. These rates are consistent with previous literature. DyC-OCT affords a new perspective on the poorly understood choriocapillaris blood flow and kinetics and may be useful for studying outer retinal diseases.

  10. Focusing on a complete blood cell parameter: mean platelet volume levels may be a predictor of coronary slow flow.

    Science.gov (United States)

    Yılmaz, Mücahid; Dağlı, Mustafa Necati; Uku, Ökkeş; Bilen, Mehmet Nail; Korkmaz, Hasan; Erdem, Kenan; Kurtoğlu, Ertuğrul

    2017-01-01

    The relationship between increased mean platelet volume (MPV) and atherosclerosis is well known. In the present study, MPV in patients with coronary slow flow (CSF) and in cases with normal coronary anatomy (NCA) was investigated and compared with the aim of identifying the relationship between CSF and MPV. We studied 40 patients previously determined via coronary angiography as having NCA and 40 patients with CSF in the coronary blood stream, as identified by thrombolysis in myocardial infarction square. Thus, a total of 80 patients from the Elaziğ Education and Research Hospital (Elaziğ, Turkey) were included in the present study retrospectively and laboratory and anamnesis information was scanned into their files. The relationship between MPV and CSF was studied. MPV levels were observed to be significantly higher in the CSF group compared to the NCA group (10.05±1.3 and 8.6±0.6, p9.05 measured in CSF patients at application had a predictive specificity of 77.5% and sensitivity of 77.5% for CSF (area under the curve: 0.825, 95% confidence interval [CI]: 0.726-0.924, p<0.0001). It was found that MPV level was an independent predictor of CSF (β=-600, p<0.001, 95% CI: -0.383 to -0.176). MPV is increased in patients with CSF when compared to patients with NCA. This finding supports the fact that MPV could be a predictor of CSF.

  11. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: II. Normal values and gray matter blood flow response to visual activation

    DEFF Research Database (Denmark)

    Law, I; Iida, H; Holm, S

    2000-01-01

    One of the most limiting factors for the accurate quantification of physiologic parameters with positron emission tomography (PET) is the partial volume effect (PVE). To assess the magnitude of this contribution to the measurement of regional cerebral blood flow (rCBF), the authors have formulated...... matter flow. Furthermore, rCBF based on the autoradiographic method was measured. The goals of the study were to determine the following in normal humans: (1) the optimal model, (2) the optimal length of fit, (3) the model parameters and their reproducibility, and (4) the effects of data acquisition (2D......CBF in normal humans. The potential use of this method is to cost-effectively deliver PVE corrected measures of rCBF and tissue volumes without reference to imaging modalities other than PET...

  12. Focusing on a complete blood cell parameter: mean platelet volume levels may be a predictor of coronary slow flow

    Directory of Open Access Journals (Sweden)

    Yılmaz M

    2017-07-01

    Full Text Available Mücahid Yılmaz,1 Mustafa Necati Dağlı,2 Ökkeş Uku,1 Mehmet Nail Bilen,1 Hasan Korkmaz,2 Kenan Erdem,3 Ertuğrul Kurtoğlu1 1Department of Cardiology, Elazığ Education and Research Hospital, 2Department of Cardiology, FIRAT University School of Medicine, Elazığ, 3Department of Cardiology, Sivas Hospital State, Sivas, Turkey Background: The relationship between increased mean platelet volume (MPV and atherosclerosis is well known. In the present study, MPV in patients with coronary slow flow (CSF and in cases with normal coronary anatomy (NCA was investigated and compared with the aim of identifying the relationship between CSF and MPV. Patients and methods: We studied 40 patients previously determined via coronary angiography as having NCA and 40 patients with CSF in the coronary blood stream, as identified by thrombolysis in myocardial infarction square. Thus, a total of 80 patients from the Elaziğ Education and Research Hospital (Elaziğ, Turkey were included in the present study retrospectively and laboratory and anamnesis information was scanned into their files. The relationship between MPV and CSF was studied. Results: MPV levels were observed to be significantly higher in the CSF group compared to the NCA group (10.05±1.3 and 8.6±0.6, p<0.001. In receiver operating characteristics analyses, it was determined that an MPV >9.05 measured in CSF patients at application had a predictive specificity of 77.5% and sensitivity of 77.5% for CSF (area under the curve: 0.825, 95% confidence interval [CI]: 0.726–0.924, p<0.0001. It was found that MPV level was an independent predictor of CSF (β=−600, p<0.001, 95% CI: −0.383 to −0.176. Conclusion: MPV is increased in patients with CSF when compared to patients with NCA. This finding supports the fact that MPV could be a predictor of CSF. Keywords: coronary slow flow, mean platelet volume, atherosclerosis

  13. The Pilot Study of Evaluating Fluctuation in the Blood Flow Volume of the Radial Artery, a Site for Traditional Pulse Diagnosis

    Directory of Open Access Journals (Sweden)

    Masashi Watanabe

    2016-05-01

    Full Text Available Background: Radial artery (RA pulse diagnosis has been used in traditional Asian medicine. Blood pressure (BP and pulse rate related to heart rate variability (HRV can be monitored via the RA. The fluctuation in these parameters has been assessed using fast Fourier transform (FFT analytical methods that calculate power spectra. Methods: We measured blood flow volume (Volume in the RA and evaluated its fluctuations. Normal participants (n = 34 were enrolled. We measured the hemodynamics of the right RA for approximately 50 s using ultrasonography. Results: The parameters showed the center frequency (CF of the power spectrum at low frequency (LF and high frequency (HF. More than one spectral component indicated that there were fluctuations. The CF at LF for Volume was significantly different from that for vessel diameter (VD; however, it was significantly correlated with blood flow velocity (Velocity. On the other hand, the CF at HF for Volume was significantly different from that for Velocity; however, it was significantly correlated with VD. Conclusion: It is suggested that fluctuation in the Volume at LF of RA is influenced by the fluctuation in Velocity; on the other hand, fluctuation in the Volume at HF is influenced by the fluctuation in VD.

  14. The influence of hyperoxia on regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV) and cerebral blood flow velocity in the middle cerebral artery (CBFVMCA) in human volunteers.

    Science.gov (United States)

    Kolbitsch, Christian; Lorenz, Ingo H; Hörmann, Christoph; Hinteregger, Martin; Löckinger, Alexander; Moser, Patrizia L; Kremser, Christian; Schocke, Michael; Felber, Stephan; Pfeiffer, Karl P; Benzer, Arnulf

    2002-09-01

    Conflicting results reported on the effects of hyperoxia on cerebral hemodynamics have been attributed mainly to methodical and species differences. In the present study contrast-enhanced magnetic resonance imaging (MRI) perfusion measurement was used to analyze the influence of hyperoxia (fraction of inspired oxygen (FiO2) = 1.0) on regional cerebral blood flow (rCBF) and regional cerebral blood volume (rCBV) in awake, normoventilating volunteers (n = 19). Furthermore, the experiment was repeated in 20 volunteers for transcranial Doppler sonography (TCD) measurement of cerebral blood flow velocity in the middle cerebral artery (CBFV(MCA)). When compared to normoxia (FiO2 = 0.21), hyperoxia heterogeneously influenced rCBV (4.95 +/- 0.02 to 12.87 +/- 0.08 mL/100g (FiO2 = 0.21) vs. 4.50 +/- 0.02 to 13.09 +/- 0.09 mL/100g (FiO2 = 1.0). In contrast, hyperoxia diminished rCBF in all regions (68.08 +/- 0.38 to 199.58 +/- 1.58 mL/100g/min (FiO2 = 0.21) vs. 58.63 +/- 0.32 to 175.16 +/- 1.51 mL/100g/min (FiO2 = 1.0)) except in parietal and left frontal gray matter. CBFV(MCA) remained unchanged regardless of the inspired oxygen fraction (62 +/- 9 cm/s (FiO2 = 0.21) vs. 64 +/- 8 cm/s (FiO2 = 1.0)). Finding CBFV(MCA) unchanged during hyperoxia is consistent with the present study's unchanged rCBF in parietal and left frontal gray matter. In these fronto-parietal regions predominantly fed by the middle cerebral artery, the vasoconstrictor effect of oxygen was probably counteracted by increased perfusion of foci of neuronal activity controlling general behavior and arousal.

  15. The value of maximal blood flow volume on duplex ultrasonography for the diagnosis of arteriogenic erectile dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Ku, Ja Hyeon [Soonchunhyang University School of Medicine, Chunan (Korea, Republic of); Song, Yun Seob; Kim, Min Eui; Park, Young Ho; Lee, Hye Kyoung [Seoul and Military Manpower Administration, Taejeon (Korea, Republic of)

    2001-03-15

    To evaluate the usefulness of maximal blood flow volume (MBFV) measured by duplex ultrasonography (US) compared with penile tumescence measured by RigiScan in the diagnosis of arteriogenic erectile dysfunction (ED). This study included twenty six patients who performed both RigiScan and duplex US after intracorporeal injection of Prostaglandin EL. We measured tumescences of penile tip and base using RigiScan and maximal arterial diameter (MAD) and peak systolic velocity (PSV) using a 7 MHz color Doppler unit. MBFV was defined as (MAD/2){sup 2} X pi X PSV. Based on normal value, we compared MAD and MBFV, and PSV and MBFV and the correlations of each measurements were evaluated with Spearman's correlation analysis. The level of significance was P<0.05. The results between MAD and MBFV, and PSV ad MBFV based on normal values were similar, respectively. Tumescences of penile tip and base were significantly correlated with MAD (r=0.409, r=0.52, p<0.05), and PSV (r=0.565, r=0.396, p<0.05). MBFV was also significantly correlated with tumescences od penile tip and base (r=0.502, r=0.563, p<0.05). In 4 patients with abnormal MAD and normal PSV, 3 had abnormal MBFV and 1 had normal MBFV. All 3 patients with abnormal MBFV had abnormal penile tumescence and 1 patients with normal MBFV had normal tumescence. One patients with normal MAD and abnormal PSV had abnormal MBFV and penile tumescence. In our study, MBFV was accurate in the diagnosis of arteriogenic ED. Moreover, MBFV was usefulness in the diagnosis of arteriogenic ED as it could explain the case where MAD and PSV are not accoded.

  16. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: II. Normal values and gray matter blood flow response to visual activation

    DEFF Research Database (Denmark)

    Law, I; Iida, H; Holm, S

    2000-01-01

    One of the most limiting factors for the accurate quantification of physiologic parameters with positron emission tomography (PET) is the partial volume effect (PVE). To assess the magnitude of this contribution to the measurement of regional cerebral blood flow (rCBF), the authors have formulated...... four kinetic models each including a parameter defining the perfusable tissue fraction (PTF). The four kinetic models used were 2 one-tissue compartment models with (Model A) and without (Model B) a vascular term and 2 two-tissue compartment models with fixed (Model C) or variable (Model D) white...... matter flow. Furthermore, rCBF based on the autoradiographic method was measured. The goals of the study were to determine the following in normal humans: (1) the optimal model, (2) the optimal length of fit, (3) the model parameters and their reproducibility, and (4) the effects of data acquisition (2D...

  17. Immersive volume rendering of blood vessels

    Science.gov (United States)

    Long, Gregory; Kim, Han Suk; Marsden, Alison; Bazilevs, Yuri; Schulze, Jürgen P.

    2012-03-01

    In this paper, we present a novel method of visualizing flow in blood vessels. Our approach reads unstructured tetrahedral data, resamples it, and uses slice based 3D texture volume rendering. Due to the sparse structure of blood vessels, we utilize an octree to efficiently store the resampled data by discarding empty regions of the volume. We use animation to convey time series data, wireframe surface to give structure, and utilize the StarCAVE, a 3D virtual reality environment, to add a fully immersive element to the visualization. Our tool has great value in interdisciplinary work, helping scientists collaborate with clinicians, by improving the understanding of blood flow simulations. Full immersion in the flow field allows for a more intuitive understanding of the flow phenomena, and can be a great help to medical experts for treatment planning.

  18. Blood flow and microgravity

    Science.gov (United States)

    Bureau, Lionel; Coupier, Gwennou; Dubois, Frank; Duperray, Alain; Farutin, Alexander; Minetti, Christophe; Misbah, Chaouqi; Podgorski, Thomas; Tsvirkun, Daria; Vysokikh, Mikhail

    2017-01-01

    The absence of gravity during space flight can alter cardio-vascular functions partially due to reduced physical activity. This affects the overall hemodynamics, and in particular the level of shear stresses to which blood vessels are submitted. Long-term exposure to space environment is thus susceptible to induce vascular remodeling through a mechanotransduction cascade that couples vessel shape and function with the mechanical cues exerted by the circulating cells on the vessel walls. Central to such processes, the glycocalyx - i.e. the micron-thick layer of biomacromolecules that lines the lumen of blood vessels and is directly exposed to blood flow - is a major actor in the regulation of biochemical and mechanical interactions. We discuss in this article several experiments performed under microgravity, such as the determination of lift force and collective motion in blood flow, and some preliminary results obtained in artificial microfluidic circuits functionalized with endothelium that offer interesting perspectives for the study of the interactions between blood and endothelium in healthy condition as well as by mimicking the degradation of glycocalyx caused by long space missions. A direct comparison between experiments and simulations is discussed. xml:lang="fr"

  19. Retinotopic Changes in the Gray Matter Volume and Cerebral Blood Flow in the Primary Visual Cortex of Patients With Primary Open-Angle Glaucoma.

    Science.gov (United States)

    Zhang, Shaodan; Wang, Bo; Xie, Yuan; Zhu, SenHua; Thomas, Ravi; Qing, Guoping; Zhang, Chun; Wang, Ningli

    2015-09-01

    To assess the cortical structure and cerebral blood flow changes in the brain of patients with primary open-angle glaucoma (POAG). High-resolution anatomical magnetic resonance imaging (MRI) and arterial spin labeling (ASL)-MRI were performed in 23 POAG patients and 29 controls. Patients were further divided into early-moderate and advanced groups based on mean deviation (MD) cutoff of 12 dB. A baseline scan was obtained and repeated during visual stimulation to the central preserved visual field in the more affected eye of POAG patients and a randomly selected eye of controls. Gray matter volume (GMV) and cerebral blood flow (CBF) throughout the whole brain were compared between patients and controls. Compared to controls, a region with significant reduction of GMV was detected in the anterior calcarine fissure of advanced POAG patients (P Primary open-angle glaucoma patients demonstrate a disease severity-dependent retinotopic pattern of cortical atrophy and CBF abnormalities in the visual cortex. Cerebral blood flow may be a potential biomarker for the brain involvement in glaucoma.

  20. Decrease of pulmonary blood flow detected by phase contrast MRI is correlated with a decrease in lung volume and increase of lung fibrosis area determined by computed tomography in interstitial lung disease.

    Science.gov (United States)

    Tsuchiya, Nanae; Yamashiro, Tsuneo; Murayama, Sadayuki

    2016-09-01

    Lung volume and pulmonary blood flow decrease in patients with interstitial lung disease (ILD). The purpose of this study was to assess the relationship between pulmonary blood flow and lung volume in ILD patients. This research was approved by the institutional review board. Twenty-seven patients (9 men, 18 women; mean age, 59 years; range, 24-79 years) with ILD were included. Blood flow was assessed in the pulmonary trunk and the left and right pulmonary arteries by phase contrast magnetic resonance imaging (MRI). Lung volume and the computed tomography (CT) visual score that indicates the severity of ILD were assessed on the left and right sides by thin-section CT scanning. Lung volume was automatically measured by lung analysis software (VINCENT Ver. 4). The CT visual score was measured by averaging the proportion of abnormal lung area at five anatomic levels. Pearson's correlation coefficient was used to determine the relationship between pulmonary blood flow and lung volume. Pulmonary blood flow showed a significant correlation with lung volume (both: r=0.52, p=0.006; left: r=0.61, p=0.001; right: r=0.54, p=0.004) and CT visual score (both: r=-0.39, p=0.04; left: r=-0.48, p=0.01; right: r=-0.38, p=0.04). Partial correlation analysis, controlled for age, height and weight, showed a significant correlation between pulmonary blood flow and lung volume (both: r=0.43, p=0.03; left: r=0.55, p=0.005; right: r=0.48, p=0.01) and CT visual score (both: r=-0.58, p=0.003; left: r=-0.51, p=0.01; right: r=-0.64, p=0.001). In ILD, reduced pulmonary blood flow is associated with reduced lung volume and increased abnormal lung area. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Local Control of Blood Flow

    Science.gov (United States)

    Clifford, Philip S.

    2011-01-01

    Organ blood flow is determined by perfusion pressure and vasomotor tone in the resistance vessels of the organ. Local factors that regulate vasomotor tone include myogenic and metabolic autoregulation, flow-mediated and conducted responses, and vasoactive substances released from red blood cells. The relative importance of each of these factors…

  2. Blood flow distribution in cerebral arteries.

    Science.gov (United States)

    Zarrinkoob, Laleh; Ambarki, Khalid; Wåhlin, Anders; Birgander, Richard; Eklund, Anders; Malm, Jan

    2015-03-31

    High-resolution phase-contrast magnetic resonance imaging can now assess flow in proximal and distal cerebral arteries. The aim of this study was to describe how total cerebral blood flow (tCBF) is distributed into the vascular tree with regard to age, sex and anatomic variations. Forty-nine healthy young (mean 25 years) and 45 elderly (mean 71 years) individuals were included. Blood flow rate (BFR) in 21 intra- and extracerebral arteries was measured. Total cerebral blood flow was defined as BFR in the internal carotid plus vertebral arteries and mean cerebral perfusion as tCBF/brain volume. Carotid/vertebral distribution was 72%/28% and was not related to age, sex, or brain volume. Total cerebral blood flow (717 ± 123 mL/min) was distributed to each side as follows: middle cerebral artery (MCA), 21%; distal MCA, 6%; anterior cerebral artery (ACA), 12%, distal ACA, 4%; ophthalmic artery, 2%; posterior cerebral artery (PCA), 8%; and 20% to basilar artery. Deviating distributions were observed in subjects with 'fetal' PCA. Blood flow rate in cerebral arteries decreased with increasing age (Psystem.

  3. Using flow feature to extract pulsatile blood flow from 4D flow MRI images

    Science.gov (United States)

    Wang, Zhiqiang; Zhao, Ye; Yu, Whitney; Chen, Xi; Lin, Chen; Kralik, Stephen F.; Hutchins, Gary D.

    2017-02-01

    4D flow MRI images make it possible to measure pulsatile blood flow inside deforming vessel, which is critical in accurate blood flow visualization, simulation, and evaluation. Such data has great potential to overcome problems in existing work, which usually does not reflect the dynamic nature of elastic vessels and blood flows in cardiac cycles. However, the 4D flow MRI data is often low-resolution and with strong noise. Due to these challenges, few efforts have been successfully conducted to extract dynamic blood flow fields and deforming artery over cardiac cycles, especially for small artery like carotid. In this paper, a robust flow feature, particularly the mean flow intensity is used to segment blood flow regions inside vessels from 4D flow MRI images in whole cardiac cycle. To estimate this flow feature more accurately, adaptive weights are added to the raw velocity vectors based on the noise strength of MRI imaging. Then, based on this feature, target arteries are tracked in at different time steps in a cardiac cycle. This method is applied to the clinical 4D flow MRI data in neck area. Dynamic vessel walls and blood flows are effectively generated in a cardiac cycle in the relatively small carotid arteries. Good image segmentation results on 2D slices are presented, together with the visualization of 3D arteries and blood flows. Evaluation of the method was performed by clinical doctors and by checking flow volume rates in the vertebral and carotid arteries.

  4. Endovascular blood flow measurement system

    Science.gov (United States)

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu

    2016-06-01

    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  5. Hyperhomocysteinemia decreases bone blood flow

    Directory of Open Access Journals (Sweden)

    Neetu T

    2011-01-01

    Full Text Available Neetu Tyagi*, Thomas P Vacek*, John T Fleming, Jonathan C Vacek, Suresh C TyagiDepartment of Physiology and Biophysics, School of Medicine, University of Louisville, Louisville, KY, USA *These authors have equal authorshipAbstract: Elevated plasma levels of homocysteine (Hcy, known as hyperhomocysteinemia (HHcy, are associated with osteoporosis. A decrease in bone blood flow is a potential cause of compromised bone mechanical properties. Therefore, we hypothesized that HHcy decreases bone blood flow and biomechanical properties. To test this hypothesis, male Sprague–Dawley rats were treated with Hcy (0.67 g/L in drinking water for 8 weeks. Age-matched rats served as controls. At the end of the treatment period, the rats were anesthetized. Blood samples were collected from experimental or control rats. Biochemical turnover markers (body weight, Hcy, vitamin B12, and folate were measured. Systolic blood pressure was measured from the right carotid artery. Tibia blood flow was measured by laser Doppler flow probe. The results indicated that Hcy levels were significantly higher in the Hcy-treated group than in control rats, whereas vitamin B12 levels were lower in the Hcy-treated group compared with control rats. There was no significant difference in folate concentration and blood pressure in Hcy-treated versus control rats. The tibial blood flow index of the control group was significantly higher (0.78 ± 0.09 flow unit compared with the Hcy-treated group (0.51 ± 0.09. The tibial mass was 1.1 ± 0.1 g in the control group and 0.9 ± 0.1 in the Hcy-treated group. The tibia bone density was unchanged in Hcy-treated rats. These results suggest that Hcy causes a reduction in bone blood flow, which contributes to compromised bone biomechanical properties.Keywords: homocysteine, tibia, bone density

  6. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET

    DEFF Research Database (Denmark)

    Iida, H; Law, I; Pakkenberg, B

    2000-01-01

    Limited spatial resolution of positron emission tomography (PET) can cause significant underestimation in the observed regional radioactivity concentration (so-called partial volume effect or PVE) resulting in systematic errors in estimating quantitative physiologic parameters. The authors have...... in the corresponding ROIs. Reproducibility of the estimated parameters and sensitivity to various error sources were also evaluated. All models tested in the current study yielded PVE-corrected regional CBF values (approximately 0.8 mL x min(-1) x g(-1) for models with a term for gray matter tissue and 0.5 mL x min(-1...... that included two parallel tissue compartments demonstrated better results with regards to the agreement of tissue time-activity curve and the Akaike's Information Criteria. Error sensitivity analysis suggested the model that fits three parameters of the gray matter CBF, the gray matter fraction, and the white...

  7. Reduced central blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik; Bendtsen, Flemming; Sørensen, T I

    1989-01-01

    for measuring the central blood volume. We have developed a method that enables us to determine directly the central blood volume, i.e., the blood volume in the heart cavities, lungs, and central arterial tree. In 60 patients with cirrhosis and 16 control subjects the central blood volume was assessed according......The pathogenesis of ascites formation in cirrhosis is uncertain. It is still under debate whether the effective blood volume is reduced (underfilling theory) or whether the intravascular compartment is expanded (overflow theory). This problem has not yet been solved because of insufficient tools...... to the kinetic theory as the product of cardiac output and mean transit time of the central vascular bed. Central blood volume was significantly smaller in patients with cirrhosis than in controls (mean 21 vs. 27 ml/kg estimated ideal body weight, p less than 0.001; 25% vs. 33% of the total blood volume, p less...

  8. Effects of Low-Intensity Cycle Training with Restricted Leg Blood Flow on Thigh Muscle Volume and VO2MAX in Young Men.

    Science.gov (United States)

    Abe, Takashi; Fujita, Satoshi; Nakajima, Toshiaki; Sakamaki, Mikako; Ozaki, Hayao; Ogasawara, Riki; Sugaya, Masato; Kudo, Maiko; Kurano, Miwa; Yasuda, Tomohiro; Sato, Yoshiaki; Ohshima, Hiroshi; Mukai, Chiaki; Ishii, Naokata

    2010-01-01

    Concurrent improvements in aerobic capacity and muscle hypertrophy in response to a single mode of training have not been reported. We examined the effects of low-intensity cycle exercise training with and without blood flow restriction (BFR) on muscle size and maximum oxygen uptake (VO2max). A group of 19 young men (mean age ± SD: 23.0 ± 1.7 years) were allocated randomly into either a BFR-training group (n=9, BFR-training) or a non-BFR control training group (n=10, CON-training), both of which trained 3 days/wk for 8 wk. Training intensity and duration were 40% of VO2max and 15 min for the BFR-training group and 40% of VO2max and 45 min for the CON-training group. MRI-measured thigh and quadriceps muscle cross-sectional area and muscle volume increased by 3.4-5.1% (P training group. There was no change in muscle size (~0.6%) and strength (~1.4%) in the CON-training group. Significant improvements in VO2max (6.4%) and exercise time until exhaustion (15.4%) were observed in the BFR-training group (p training group (-0.1 and 3. 9%, respectively). The results suggest that low-intensity, short-duration cycling exercise combined with BFR improves both muscle hypertrophy and aerobic capacity concurrently in young men. Key pointsConcurrent improvements in aerobic capacity and muscle hypertrophy in response to a single mode of training have not been reported.In the present study, low-intensity (40% of VO2max) cycle training with BFR can elicit concurrent improvement in muscle hypertrophy and aerobic capacity.

  9. EFFECTS OF LOW-INTENSITY CYCLE TRAINING WITH RESTRICTED LEG BLOOD FLOW ON THIGH MUSCLE VOLUME AND VO2MAX IN YOUNG MEN

    Directory of Open Access Journals (Sweden)

    Takashi Abe

    2010-09-01

    Full Text Available Concurrent improvements in aerobic capacity and muscle hypertrophy in response to a single mode of training have not been reported. We examined the effects of low-intensity cycle exercise training with and without blood flow restriction (BFR on muscle size and maximum oxygen uptake (VO2max. A group of 19 young men (mean age ± SD: 23.0 ± 1.7 years were allocated randomly into either a BFR-training group (n=9, BFR-training or a non-BFR control training group (n=10, CON-training, both of which trained 3 days/wk for 8 wk. Training intensity and duration were 40% of VO2max and 15 min for the BFR-training group and 40% of VO2max and 45 min for the CON-training group. MRI-measured thigh and quadriceps muscle cross-sectional area and muscle volume increased by 3.4-5.1% (P < 0.01 and isometric knee extension strength tended to increase by 7.7% (p < 0.10 in the BFR-training group. There was no change in muscle size (~0.6% and strength (~1.4% in the CON-training group. Significant improvements in VO2max (6.4% and exercise time until exhaustion (15.4% were observed in the BFR-training group (p < 0.05 but not in the CON-training group (-0.1 and 3. 9%, respectively. The results suggest that low-intensity, short-duration cycling exercise combined with BFR improves both muscle hypertrophy and aerobic capacity concurrently in young men.

  10. Reduced central blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Bendtsen, F; Henriksen, Jens Henrik Sahl; Sørensen, T I

    1989-01-01

    to the kinetic theory as the product of cardiac output and mean transit time of the central vascular bed. Central blood volume was significantly smaller in patients with cirrhosis than in controls (mean 21 vs. 27 ml/kg estimated ideal body weight, p less than 0.001; 25% vs. 33% of the total blood volume, p less...

  11. Cerebral blood-flow tomography

    DEFF Research Database (Denmark)

    Lassen, N A; Henriksen, L; Holm, S

    1983-01-01

    . The Xe-133 flow maps are essentially based on the average Xe-133 concentration over the initial 2 min during and after an inhalation of the inert gas lasting 1 min. These maps agreed very well with the early IMP maps obtained over the initial 10 min following an i.v. bolus injection. The subsequent IMP......, and with low radiation exposure to patient and personnel. On the other hand, IMP gives an image of slightly higher resolution. It also introduces a new class of iodinated brain-seeking compounds allowing, perhaps, imaging of other functions more important than mere blood flow....

  12. Effect of pulmonary hyperinflation on central blood volume

    DEFF Research Database (Denmark)

    Mijacika, Tanja; Kyhl, Kasper; Frestad, Daria

    2017-01-01

    assessed by magnetic resonance imaging in twelve breath-hold divers at rest and during apnea with GPI. Pulmonary blood volume was determined from pulmonary blood flow and transit times for gadolinium during first-pass perfusion after intravenous injection. During GPI, the lung volume increased by 0.8±0.6L...... (11±7%) above the total lung capacity. All cardiac chambers decreased in volume and despite a heart rate increase of 24±29 bpm (39±50%), pulmonary blood flow decreased by 2783±1820mL (43±20%). The pulmonary transit time remained unchanged at 7.5±2.2s and pulmonary blood volume decreased by 354±176m......Pulmonary hyperinflation attained by glossopharyngeal insufflation (GPI) challenges the circulation by compressing the heart and pulmonary vasculature. Our aim was to determine the amount of blood translocated from the central blood volume during GPI. Cardiac output and cardiac chamber volumes were...

  13. Ocular Blood Flow Autoregulation Mechanisms and Methods

    Directory of Open Access Journals (Sweden)

    Xue Luo

    2015-01-01

    Full Text Available The main function of ocular blood flow is to supply sufficient oxygen and nutrients to the eye. Local blood vessels resistance regulates overall blood distribution to the eye and can vary rapidly over time depending on ocular need. Under normal conditions, the relation between blood flow and perfusion pressure in the eye is autoregulated. Basically, autoregulation is a capacity to maintain a relatively constant level of blood flow in the presence of changes in ocular perfusion pressure and varied metabolic demand. In addition, ocular blood flow dysregulation has been demonstrated as an independent risk factor to many ocular diseases. For instance, ocular perfusion pressure plays key role in the progression of retinopathy such as glaucoma and diabetic retinopathy. In this review, different direct and indirect techniques to measure ocular blood flow and the effect of myogenic and neurogenic mechanisms on ocular blood flow are discussed. Moreover, ocular blood flow regulation in ocular disease will be described.

  14. Diagnostic examination performance by using microvascular leakage, cerebral blood volume, and blood flow derived from 3-T dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in the differentiation of glioblastoma multiforme and brain metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Server, Andres; Nakstad, Per H. [Oslo University Hospital-Ullevaal, Section of Neuroradiology, Department of Radiology and Nuclear Medicine, Oslo (Norway); University of Oslo, Oslo (Norway); Orheim, Tone E.D. [Oslo University Hospital, Interventional Centre, Oslo (Norway); Graff, Bjoern A. [Oslo University Hospital-Ullevaal, Department of Radiology and Nuclear Medicine, Oslo (Norway); Josefsen, Roger [Oslo University Hospital-Ullevaal, Department of Neurosurgery, Oslo (Norway); Kumar, Theresa [Oslo University Hospital-Ullevaal, Department of Pathology, Oslo (Norway)

    2011-05-15

    Conventional magnetic resonance (MR) imaging has limited capacity to differentiate between glioblastoma multiforme (GBM) and metastasis. The purposes of this study were: (1) to compare microvascular leakage (MVL), cerebral blood volume (CBV), and blood flow (CBF) in the distinction of metastasis from GBM using dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging (DSC-MRI), and (2) to estimate the diagnostic accuracy of perfusion and permeability MR imaging. A prospective study of 61 patients (40 GBMs and 21 metastases) was performed at 3 T using DSC-MRI. Normalized rCBV and rCBF from tumoral (rCBVt, rCBFt), peri-enhancing region (rCBVe, rCBFe), and by dividing the value in the tumor by the value in the peri-enhancing region (rCBVt/e, rCBFt/e), as well as MVL were calculated. Hemodynamic and histopathologic variables were analyzed statistically and Spearman/Pearson correlations. Receiver operating characteristic curve analysis was performed for each of the variables. The rCBVe, rCBFe, and MVL were significantly greater in GBMs compared with those of metastases. The optimal cutoff value for differentiating GBM from metastasis was 0.80 which implies a sensitivity of 95%, a specificity of 92%, a positive predictive value of 86%, and a negative predictive value of 97% for rCBVe ratio. We found a modest correlation between rCBVt and rCBFt ratios. MVL measurements in GBMs are significantly higher than those in metastases. Statistically, both rCBVe, rCBVt/e and rCBFe, rCBFt/e were useful in differentiating between GBMs and metastases, supporting the hypothesis that perfusion MR imaging can detect infiltration of tumor cells in the peri-enhancing region. (orig.)

  15. Blood flow rate measurements with indicator techniques revisited

    DEFF Research Database (Denmark)

    Sejrsen, Per; Bülow, Jens

    2009-01-01

    In view of the emerging role, disturbances in regional blood flow rate seem to play in the pathogenesis of the metabolic syndrome; we review the concepts of the classical indicator dilution and washout techniques used for determinations of regional blood flow rate. Prerequisites, assumptions......, necessary precautions for the application of these experimental techniques are emphasized. Special attention has been carried out to elucidate the consequence of a choice of indicators having a large distribution volume in the tissues....

  16. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-{sup 123}I IMP single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi [National Saigata Hospital, Ohagata, Niigata (Japan)

    2001-09-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V{sub d}) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ({sup 123}I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the {sup 123}I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p<0.01) and cerebellar vermis (p<0.05). The V{sub d} was also significantly decreased in the pons (p<0.005) in comparison with that for normal subjects. Pearson's correlation analysis yielded a significant relationship between the rCBF in the pons and age at onset (r=0.578, p<0.05). There was a strong correlation between the V{sub d} for the pons and age at onset (r=0.59, p<0.05). Person's correlation analysis also showed a significant relationship between the V{sub d} in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p<0.05). The pontine rCBFs in patients with early onset MJD

  17. Impact of transvaginal hydrolaparoscopy ovarian drilling on ovarian stromal blood flow and ovarian volume in clomiphene citrate-resistant PCOS patients: a case-control study.

    Science.gov (United States)

    Giampaolino, Pierluigi; Morra, Ilaria; De Rosa, Nicoletta; Cagnacci, Angelo; Pellicano, Massimiliano; Di Carlo, Costantino; Nappi, Carmine; Bifulco, Giuseppe

    2017-09-01

    Polycystic ovarian syndrome (PCOS) is the most common endocrine disorder in gynecology. In PCOS patients vascularization parameters are altered. Transvaginal hydrolaparoscopy (THL) is a mini-invasive approach for ovarian drilling in PCOS patients. In this study, we assessed the effect of ovarian drilling using THL on ovarian volume (OV) and vascularization index (VI) using 3D power Doppler ultrasonography in CC-resistant PCOS patients. A case-control study on 123 CC-resistant PCOS women who underwent THL ovarian drilling was performed. Patients underwent 3D ultrasound and power Doppler to measure VI, flow index (FI), vascularization flow index (VFI) and to evaluate OV before and after the procedure, at six months, and on the early follicular phase of the menstrual cycle. After THL ovarian drilling, OV and power Doppler flow indices were significantly reduced compared to pre-operative values (OV: 7.85 versus 11.72 cm 3 , p PCOS patients resistant to medical therapy.

  18. Postishemic Cerebral Function and Blood Flow

    Directory of Open Access Journals (Sweden)

    V. V. Aleksandrin

    2005-01-01

    Full Text Available The impact of massive blood loss on cerebral blood flow-function relationships was studied in rats in the postis-chemic period. Anxiety was examined in the raised cross-shaped labyrinth. Cerebral blood flow was registered by a laser Doppler flowmeter. One-hour massive blood flow substantially increased the level of anxiety in 75% of the rats following 7 and 20 days. There were no significant behavior changes in 25% of the animals. Experimental animals with preserved behavioral parameters showed cerebral blood flow resistance to ischemia and reperfusion while rats with increased anxiety were found to have delayed postischemic hypoperfusion. Thus, a relationship was found between the behavior of the rats and the resistance of cerebral blood flow to ischemia and reperfusion.

  19. Effects of Pulsatile Blood Flow on Oxygenator Performance.

    Science.gov (United States)

    Schraven, Lotte; Kaesler, Andreas; Flege, Christian; Kopp, Rüdger; Schmitz-Rode, Thomas; Steinseifer, Ulrich; Arens, Jutta

    2018-02-13

    Extracorporeal membrane oxygenation (ECMO) is mainly used for the therapy of acute respiratory distress syndrome and chronic obstructive lung disease. In the last years, the development of these systems underwent huge steps in optimization, but there are still problems with thrombus formation, clogging, and thus insufficient gas exchange. One idea of ECMO optimization is a pulsatile blood flow through the oxygenator, but this is still a controversy discussion. Analyzing available publications, it was not possible to identify a general statement about the effect of pulsatile blood flow on the gas exchange performance. The variety of parameters and circuit components have such a high influence on the outcome that a direct comparison of the studies is difficult. For this reason, we performed a structured study to evaluate the effects of pulsatile blood flow on the gas exchange performance of oxygenator. In in vitro tests according to DIN EN ISO 7199, we tested a small oxygenator (0.25 m 2 exchange surface, polymethylpentene fibers, 33 mL priming volume) with constant and pulsatile blood flow in comparison. Therefore, we varied the mean blood flow from 250 to 1200 mL/min, the amplitude of 0, 20, and 50%, and the frequency of 30, 60, and 90 bpm. The results demonstrate that the gas transfer for pulsatile and constant blood flow was similar (oxygen: 36-64 mL O2 /L Blood ; carbon dioxide 35-80 mL CO2 /L Blood ) for the same mean blood flow ranges. Over all, the results and analyses showed a statistically nonsignificant difference between pulsatile and nonpulsatile flow. Consequently, we conclude that the implementation of pulsatile blood flow has only a small to no effect on the gas exchange performance in an oxygenator. As the results were obtained using an oxygenator with a coiled fiber bundle, the test must be verified for a stacked fiber oxygenator. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Continuous Blood Volume Monitoring and Ultrafiltration Control.

    Science.gov (United States)

    Lopot, František; Nejedlý, Bohdan; Sulková, Sylvie

    2000-01-01

    Continuous blood volume monitoring (CBVM) is believed to be a promising method for making the determination of patients' "dry weight" more objective, and ultrafiltration (UF) control more appropriate. Although blood volume response to UF and the interrelation between blood volume changes and changes in hemodynamic parameters are highly individual, certain principles of this response and interrelation can be identified and exploited for effective use of CBVM. The present work summarizes the authors' findings from practical CBVM application over the past 5 years and their opinions on the future development of this method. Four distinct types of blood volume response to constant UF rate were identified: Type 1, flat line throughout the whole session; Type 2, flat line during the first part of dialysis, followed by a linear decrease during the remaining time; Type 3, linear decrease right from dialysis start; and Type 4, linear decrease first, followed by a flat line during the remaining time. The possibility of a shift from one type to the other was verified. Blood volume reduction due to UF was found to have a static and a dynamic component. The most important factors affecting both components were found to be, by sensitivity analysis of a three-pool kinetic model, degree of overhydration, vascular system compliance, and UF volume (for the static component); and UF coefficient of the capillary wall and UF rate (for the dynamic component). Type 3 response, induced by more vigorous UF, was found to significantly decrease the volume of residual daily diuresis on the first postdialysis day. If confirmed, this finding may serve as a basis for the response type choice in patients with still significant residual renal function. Exploitation of the existence of dynamic blood volume reduction component for the first generation of automated biofeedback UF controllers may be complemented by automated identification of patient's plasma refilling capacity and/or position of his

  1. Regulation of coronary blood flow during exercise.

    Science.gov (United States)

    Duncker, Dirk J; Bache, Robert J

    2008-07-01

    collateral system embodies a dynamic network of interarterial vessels that can undergo both long- and short-term adjustments that can modulate blood flow to the dependent myocardium. Long-term adjustments including recruitment and growth of collateral vessels in response to arterial occlusion are time dependent and determine the maximum blood flow rates available to the collateral-dependent vascular bed during exercise. Rapid short-term adjustments result from active vasomotor activity of the collateral vessels. Mature coronary collateral vessels are responsive to vasodilators such as nitroglycerin and atrial natriuretic peptide, and to vasoconstrictors such as vasopressin, angiotensin II, and the platelet products serotonin and thromboxane A(2). During exercise, ss-adrenergic activity and endothelium-derived NO and prostanoids exert vasodilator influences on coronary collateral vessels. Importantly, alterations in collateral vasomotor tone, e.g., by exogenous vasopressin, inhibition of endogenous NO or prostanoid production, or increasing local adenosine production can modify collateral conductance, thereby influencing the blood supply to the dependent myocardium. In addition, vasomotor activity in the resistance vessels of the collateral perfused vascular bed can influence the volume and distribution of blood flow within the collateral zone. Finally, there is evidence that vasomotor control of resistance vessels in the normally perfused regions of collateralized hearts is altered, indicating that the vascular adaptations in hearts with a flow-limiting coronary obstruction occur at a global as well as a regional level. Exercise training does not stimulate growth of coronary collateral vessels in the normal heart. However, if exercise produces ischemia, which would be absent or minimal under resting conditions, there is evidence that collateral growth can be enhanced. In addition to ischemia, the pressure gradient between vascular beds, which is a determinant of the flow

  2. Blood flow reprograms lymphatic vessels to blood vessels.

    Science.gov (United States)

    Chen, Chiu-Yu; Bertozzi, Cara; Zou, Zhiying; Yuan, Lijun; Lee, John S; Lu, MinMin; Stachelek, Stan J; Srinivasan, Sathish; Guo, Lili; Vicente, Andres; Vincente, Andres; Mericko, Patricia; Levy, Robert J; Makinen, Taija; Oliver, Guillermo; Kahn, Mark L

    2012-06-01

    Human vascular malformations cause disease as a result of changes in blood flow and vascular hemodynamic forces. Although the genetic mutations that underlie the formation of many human vascular malformations are known, the extent to which abnormal blood flow can subsequently influence the vascular genetic program and natural history is not. Loss of the SH2 domain-containing leukocyte protein of 76 kDa (SLP76) resulted in a vascular malformation that directed blood flow through mesenteric lymphatic vessels after birth in mice. Mesenteric vessels in the position of the congenital lymphatic in mature Slp76-null mice lacked lymphatic identity and expressed a marker of blood vessel identity. Genetic lineage tracing demonstrated that this change in vessel identity was the result of lymphatic endothelial cell reprogramming rather than replacement by blood endothelial cells. Exposure of lymphatic vessels to blood in the absence of significant flow did not alter vessel identity in vivo, but lymphatic endothelial cells exposed to similar levels of shear stress ex vivo rapidly lost expression of PROX1, a lymphatic fate-specifying transcription factor. These findings reveal that blood flow can convert lymphatic vessels to blood vessels, demonstrating that hemodynamic forces may reprogram endothelial and vessel identity in cardiovascular diseases associated with abnormal flow.

  3. Bone blood flow and metabolism in humans

    DEFF Research Database (Denmark)

    Heinonen, Ilkka; Kemppainen, Jukka; Kaskinoro, Kimmo

    2012-01-01

    Human bone blood flow and metabolism during physical exercise remains poorly characterised. In the present study we measured femoral bone blood flow and glucose uptake in young healthy subjects by positron emission tomography in three separate protocols. In six women, blood flow was measured...... in femoral bone at rest and during one leg intermittent isometric exercise with increasing exercise intensities. In nine men, blood flow in femur was determined at rest and during dynamic one leg exercise, and two other physiological perturbations: moderate systemic hypoxia (14 O(2) ) at rest and during...... exercise, and during intra-femoral infusion of high-dose adenosine. Bone glucose uptake was measured at rest and during dynamic one leg exercise in five men. The results indicate that isometric exercise increased femoral bone blood flow from rest (1.8 ± 0.6 ml/100g/min) to low intensity exercise (4.1 ± 1...

  4. Ciliary Blood Flow and Aqueous Humor Production

    Science.gov (United States)

    Kiel, J.W.; Hollingsworth, M.; Rao, R.; Chen, M.; Reitsamer, H.A.

    2010-01-01

    Aqueous humor production is a metabolically active process sustained by the delivery of oxygen and nutrients and removal of metabolic waste by the ciliary circulation. This article describes our investigations into the relationship between ciliary blood flow and aqueous humor production. The results presented indicate that there is a dynamic relationship between ciliary blood flow and aqueous humor production, with production being blood flow independent above a critical level of perfusion, and blood flow dependent below it. The results also show that the plateau portion of the relationship shifts up or down depending on the level of secretory stimulation or inhibition, and that oxygen is one critical factor provided by ciliary blood flow. Also presented is a theoretical model of ocular hydrodynamics incorporating these new findings. PMID:20801226

  5. The Physics of Coronary Blood Flow

    CERN Document Server

    Zamir, M

    2005-01-01

    Coronary blood flow is blood flow to the heart for its own metabolic needs. In the most common form of heart disease there is a disruption in this flow because of obstructive disease in the vessels that carry the flow. The subject of coronary blood flow is therefore associated mostly with the pathophysiology of this disease, rarely with dynamics or physics. Yet, the system responsible for coronary blood flow, namely the "coronary circulation," is a highly sophisticated dynamical system in which the dynamics and physics of the flow are as important as the integrity of the conducting vessels. While an obstruction in the conducting vessels is a fairly obvious and clearly visible cause of disruption in coronary blood flow, any discord in the complex dynamics of the system can cause an equally grave, though less conspicuous, disruption in the flow. This book is devoted specifically to the dynamics and physics of coronary blood flow. While relevance to the clinical and pathophysiological issues is clearly maintaine...

  6. Systematic survey of the design, statistical analysis, and reporting of studies published in the 2008 volume of the Journal of Cerebral Blood Flow and Metabolism.

    Science.gov (United States)

    Vesterinen, Hanna M; Vesterinen, Hanna V; Egan, Kieren; Deister, Amelie; Schlattmann, Peter; Macleod, Malcolm R; Dirnagl, Ulrich

    2011-04-01

    Translating experimental findings into clinically effective therapies is one of the major bottlenecks of modern medicine. As this has been particularly true for cerebrovascular research, attention has turned to the quality and validity of experimental cerebrovascular studies. We set out to assess the study design, statistical analyses, and reporting of cerebrovascular research. We assessed all original articles published in the Journal of Cerebral Blood Flow and Metabolism during the year 2008 against a checklist designed to capture the key attributes relating to study design, statistical analyses, and reporting. A total of 156 original publications were included (animal, in vitro, human). Few studies reported a primary research hypothesis, statement of purpose, or measures to safeguard internal validity (such as randomization, blinding, exclusion or inclusion criteria). Many studies lacked sufficient information regarding methods and results to form a reasonable judgment about their validity. In nearly 20% of studies, statistical tests were either not appropriate or information to allow assessment of appropriateness was lacking. This study identifies a number of factors that should be addressed if the quality of research in basic and translational biomedicine is to be improved. We support the widespread implementation of the ARRIVE (Animal Research Reporting In Vivo Experiments) statement for the reporting of experimental studies in biomedicine, for improving training in proper study design and analysis, and that reviewers and editors adopt a more constructively critical approach in the assessment of manuscripts for publication.

  7. Blood flow autoregulation in pedicled flaps

    DEFF Research Database (Denmark)

    Bonde, Christian T; Holstein-Rathlou, Niels-Henrik; Elberg, Jens J

    2009-01-01

    INTRODUCTION: Clinical work on the blood perfusion in skin and muscle flaps has suggested that some degree of blood flow autoregulation exists in such flaps. An autoregulatory mechanism would enable the flap to protect itself from changes in the perfusion pressure. The purpose of the present study...... was to evaluate if, and to what extent, a tissue flap could compensate a reduction in blood flow due to an acute constriction of the feed artery. Further, we wanted to examine the possible role of smooth muscle L-type calcium channels in the autoregulatory mechanism by pharmacological intervention with the L......-type calcium channel blocker nimodipine and the vasodilator papaverine. MATERIAL AND METHODS: Pedicled flaps were raised in pigs. Flow in the pedicle was reduced by constriction of the feed artery (n=34). A transit time flow probe measured the effect on blood flow continuously. Following this, three different...

  8. Hepatic and intestinal blood flow following thermal injury

    Energy Technology Data Exchange (ETDEWEB)

    Carter, E.A.; Tompkins, R.G.; Burke, J.F.

    1988-07-01

    Because cardiac output decreases after burn injuries, investigators have assumed, based upon dye clearance techniques, that hepatic and intestinal blood flow are also decreased following these injuries. Blood flow to the liver, stomach, small intestine, and kidney was determined by the uptake of 201thallium and 125I-labeled fatty acid (para-125I-phenyl-3-methyl pentanoic acid) in a 20% body surface area scald injury that also included plasma volume replacement resuscitation. Uptake of these radioisotopes was determined 15 minutes, 18 hours, and 72 hours after injury. The uptake of the 201thallium and 125I-labeled fatty acid by the gastrointestinal tissues was not statistically different at any of the time periods after comparison of the injured and control (sham-treated) animals. 201Thallium uptake by the kidney was significantly diminished 15 minutes after the burn injury (P less than 0.01). Based on these blood flow measurement techniques, the data suggest that the 20% body surface area scald injury did not alter blood flow to the liver or gastrointestinal tract within the initial 72 hours after the burn injury even though a decrease in renal blood flow was easily detected. These results suggest that the dysfunction of the gastrointestinal system or hepatic system observed after an acute burn injury is not simply the result of hypovolemic shock, which reduces both renal and mesenteric blood flow. These gastrointestinal and hepatic alterations may be related to a factor or factors other than intestinal ischemia.

  9. Non-invasive pulmonary blood flow analysis and blood pressure mapping derived from 4D flow MRI

    Science.gov (United States)

    Delles, Michael; Rengier, Fabian; Azad, Yoo-Jin; Bodenstedt, Sebastian; von Tengg-Kobligk, Hendrik; Ley, Sebastian; Unterhinninghofen, Roland; Kauczor, Hans-Ulrich; Dillmann, Rüdiger

    2015-03-01

    In diagnostics and therapy control of cardiovascular diseases, detailed knowledge about the patient-specific behavior of blood flow and pressure can be essential. The only method capable of measuring complete time-resolved three-dimensional vector fields of the blood flow velocities is velocity-encoded magnetic resonance imaging (MRI), often denoted as 4D flow MRI. Furthermore, relative pressure maps can be computed from this data source, as presented by different groups in recent years. Hence, analysis of blood flow and pressure using 4D flow MRI can be a valuable technique in management of cardiovascular diseases. In order to perform these tasks, all necessary steps in the corresponding process chain can be carried out in our in-house developed software framework MEDIFRAME. In this article, we apply MEDIFRAME for a study of hemodynamics in the pulmonary arteries of five healthy volunteers. The study included measuring vector fields of blood flow velocities by phase-contrast MRI and subsequently computing relative blood pressure maps. We visualized blood flow by streamline depictions and computed characteristic values for the left and the right pulmonary artery (LPA and RPA). In all volunteers, we observed a lower amount of blood flow in the LPA compared to the RPA. Furthermore, we visualized blood pressure maps using volume rendering and generated graphs of pressure differences between the LPA, the RPA and the main pulmonary artery. In most volunteers, blood pressure was increased near to the bifurcation and in the proximal LPA, leading to higher average pressure values in the LPA compared to the RPA.

  10. Blood Volume: Its Adaptation to Endurance Training

    Science.gov (United States)

    Convertino, Victor A.

    1991-01-01

    Expansion of blood volume (hypervolemia) has been well documented in both cross-sectional and longitudinal studies as a consequence of endurance exercise training. Plasma volume expansion can account for nearly all of the exercise-induced hypervolemia up to 2-4 wk; after this time expansion may be distributed equally between plasma and red cell volumes. The exercise stimulus for hypervolemia has both thermal and nonthermal components that increase total circulating plasma levels of electrolytes and proteins. Although protein and fluid shifts from the extravascular to intravascular space may provide a mechanism for rapid hypervolemia immediately after exercise, evidence supports the notion that chronic hypervolemia associated with exercise training represents a net expansion of total body water and solutes. This net increase of body fluids with exercise training is associated with increased water intake and decreased urine volume output. The mechanism of reduced urine output appears to be increased renal tubular reabsorption of sodium through a more sensitive aldosterone action in man. Exercise training-induced hypervolemia appears to be universal among most animal species, although the mechanisms may be quite different. The hypervolemia may provide advantages of greater body fluid for heat dissipation and thermoregulatory stability as well as larger vascular volume and filling pressure for greater cardiac stroke volume and lower heart rates during exercise.

  11. Brachial blood flow under relative levels of blood flow restriction is decreased in a nonlinear fashion.

    Science.gov (United States)

    Mouser, J Grant; Ade, Carl J; Black, Christopher D; Bemben, Debra A; Bemben, Michael G

    2017-04-12

    Blood flow restriction (BFR), the application of external pressure to occlude venous return and restrict arterial inflow, has been shown to increase muscular size and strength when combined with low-load resistance exercise. BFR in the research setting uses a wide range of pressures, applying a pressure based upon an individual's systolic pressure or a percentage of occlusion pressure; not a directly determined reduction in blood flow. The relationship between relative pressure and blood flow has not been established. To measure blood flow in the arm under relative levels of BFR. Forty-five people (18-40 years old) participated. Arterial occlusion pressure in the right arm was measured using a 5-cm pneumatic cuff. Blood flow in the brachial artery was measured at rest and at pressures between 10% and 90% of occlusion using ultrasound. Blood flow decreased in a nonlinear, stepped fashion. Blood flow decreased at 10% of occlusion and remained constant until decreasing again at 40%, where it remained until 90% of occlusion. The decrease in brachial blood flow is not proportional to the applied relative pressure. The prescription of blood flow restriction should take into account the stimulus provided at each relative level of blood flow. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  12. Frequency encoding in renal blood flow regulation

    DEFF Research Database (Denmark)

    Marsh, Donald J; Sosnovtseva, Olga; Pavlov, Alexey N

    2005-01-01

    With a model of renal blood flow regulation, we examined consequences of tubuloglomerular feedback (TGF) coupling to the myogenic mechanism via voltage-gated Ca channels. The model reproduces the characteristic oscillations of the two mechanisms and predicts frequency and amplitude modulation...... of the myogenic oscillation by TGF. Analysis by wavelet transforms of single-nephron blood flow confirms that both amplitude and frequency of the myogenic oscillation are modulated by TGF. We developed a double-wavelet transform technique to estimate modulation frequency. Median value of the ratio of modulation...... TGF cycle to the next. We used a blood pressure signal recorded by telemetry from a conscious rat as the input to the model. Blood pressure fluctuations induced variability in the modulation records similar to those found in the nephron blood flow results. Frequency and amplitude modulation can...

  13. MR assessment of absolute myocardial blood flow and vasodilator flow reserve in patients with hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Kawada, Nanaka; Sakuma, Hajime; Takeda, Kan; Nakagawa, Tsuyoshi; Yamakado, Tetsu; Nakano, Takeshi [Mie Univ., Tsu (Japan). School of Medicine

    1997-04-01

    Absolute coronary blood flow per myocardial mass and coronary flow reserve for the entire left ventricle were evaluated in normals and in patients with hypertrophic cardiomyopathy (HCM) by using fast cine MR imaging and fast velocity encoded cine (VENC) MR imaging. Nine healthy volunteers and 8 patients with HCM were studied with a 1.5 T imager. Breath-hold cine MR images encompassing the whole left ventricle were acquired on short axis imaging planes in order to evaluate myocardial mass. A fast VENC MR images were obtained to measure blood flow volume in the coronary sinus before and after dipyridamole administration (TR/TE=15/5 ms, FOV=28 x 22 cm, slice thickness=5 mm). Coronary flow reserve was calculated as a ratio of hyperemic to baseline coronary flow volumes. In the baseline state, coronary blood flow per myocardial mass was significantly lower in patients with HCM than in normal myocardium (0.56{+-}0.23 vs. 0.78{+-}0.27 ml/min/g, p<0.05). After dipyridamole administration, coronary blood flow per myocardial mass in patients with HCM increased substantially less than that in healthy subjects (0.99{+-}0.38 vs. 2.22{+-}0.55 ml/min/g, p<0.01), resulting in the significantly decreased coronary flow reserve ratio in HCM in comparison with that in normal myocardium (1.86{+-}0.56 vs. 3.11{+-}1.37, p<0.05). In conclusion, breath-hold velocity encoded cine MR imaging is a noninvasive technique which can provide assessments of altered coronary blood flow volume per myocardial mass and vasodilator flow reserve in patients with HCM. (author)

  14. One dimensional blood flow in a planetocentric orbit

    Science.gov (United States)

    Haranas, Ioannis; Gkigkitzis, Ioannis

    2012-05-01

    All life on earth is accustomed to the presence of gravity. When gravity is altered, biological processes can go awry. It is of great importance to ensure safety during a spaceflight. Long term exposure to microgravity can trigger detrimental physiological responses in the human body. Fluid redistribution coupled with fluid loss is one of the effects. In particular, in microgravity blood volume is shifted towards the thorax and head. Sympathetic nervous system-induced vasoconstriction is needed to maintain arterial pressure, while venoconstriction limits venous pooling of blood prevents further reductions in venous return of blood to the heart. In this paper, we modify an existing one dimensional blood flow model with the inclusion of the hydrostatic pressure gradient that further depends on the gravitational field modified by the oblateness and rotation of the Earth. We find that the velocity of the blood flow VB is inversely proportional to the blood specific volume d, also proportional to the oblateness harmonic coefficient J2, the angular velocity of the Earth ωE, and finally proportional to an arbitrary constant c. For c = -0.39073 and ξH = -0.5 mmHg, all orbits result to less blood flow velocities than that calculated on the surface of the Earth. From all considered orbits, elliptical polar orbit of eccentricity e = 0.2 exhibit the largest flow velocity VB = 1.031 m/s, followed by the orbits of inclination i = 45°and 0°. The Earth's oblateness and its rotation contribute a 0.7% difference to the blood flow velocity.

  15. Cerebral blood flow response to functional activation

    DEFF Research Database (Denmark)

    Paulson, Olaf B; Hasselbalch, Steen G; Rostrup, Egill

    2010-01-01

    Cerebral blood flow (CBF) and cerebral metabolic rate are normally coupled, that is an increase in metabolic demand will lead to an increase in flow. However, during functional activation, CBF and glucose metabolism remain coupled as they increase in proportion, whereas oxygen metabolism only...

  16. Neural control of choroidal blood flow.

    Science.gov (United States)

    Reiner, Anton; Fitzgerald, Malinda E C; Del Mar, Nobel; Li, Chunyan

    2017-12-08

    The choroid is richly innervated by parasympathetic, sympathetic and trigeminal sensory nerve fibers that regulate choroidal blood flow in birds and mammals, and presumably other vertebrate classes as well. The parasympathetic innervation has been shown to vasodilate and increase choroidal blood flow, the sympathetic input has been shown to vasoconstrict and decrease choroidal blood flow, and the sensory input has been shown to both convey pain and thermal information centrally and act locally to vasodilate and increase choroidal blood flow. As the choroid lies behind the retina and cannot respond readily to retinal metabolic signals, its innervation is important for adjustments in flow required by either retinal activity, by fluctuations in the systemic blood pressure driving choroidal perfusion, and possibly by retinal temperature. The former two appear to be mediated by the sympathetic and parasympathetic nervous systems, via central circuits responsive to retinal activity and systemic blood pressure, but adjustments for ocular perfusion pressure also appear to be influenced by local autoregulatory myogenic mechanisms. Adaptive choroidal responses to temperature may be mediated by trigeminal sensory fibers. Impairments in the neural control of choroidal blood flow occur with aging, and various ocular or systemic diseases such as glaucoma, age-related macular degeneration (AMD), hypertension, and diabetes, and may contribute to retinal pathology and dysfunction in these conditions, or in the case of AMD be a precondition. The present manuscript reviews findings in birds and mammals that contribute to the above-summarized understanding of the roles of the autonomic and sensory innervation of the choroid in controlling choroidal blood flow, and in the importance of such regulation for maintaining retinal health. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. 21 CFR 862.1130 - Blood volume test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume test system. 862.1130 Section 862...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862.1130 Blood volume test system. (a) Identification. A blood volume test system is a device intended to...

  18. 21 CFR 870.2120 - Extravascular blood flow probe.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Extravascular blood flow probe. 870.2120 Section... blood flow probe. (a) Identification. An extravascular blood flow probe is an extravascular ultrasonic or electromagnetic probe used in conjunction with a blood flowmeter to measure blood flow in a...

  19. Quantifying the influence of oscillatory flow disturbances on blood flow.

    Science.gov (United States)

    Gabriel, Sargon A; Ding, Yan; Feng, Yuqing

    2017-10-07

    Pulsatile blood flow is renowned for inducing localised flow disturbances that are characterised by significant oscillations. These flow disturbances are recognised to have a physiologic significance within the cardiovascular system, particularly with respect to their proatherogenic expression on endothelial cells. Flow disturbances also impart significant influence on the mechanics of cardiovascular flow and are formally shown in the present study to be coupled to the period-average behaviour of a pulsatile flow field, causing it to be misrepresented by its steady-equivalent; which is often used in models of atherogenesis and hence limits their reliability. It is demonstrated that a measure of the localised influence of flow disturbances on the period-average flow can be realised by the relative significance of their kinetic energy, which is quantified by the introduced Oscillatory Kinetic Energy Index (OKEI). A specific measure of direction-reversing oscillations is also developed with the introduction of the Oscillatory Flow Index (OFI), which is an extension of the wall-bound Oscillatory Shear Index (OSI) onto flow and wall spaces. A case study of a human carotid artery is made; wherein pulsatile flow is studied relative to its steady-equivalent state. The introduced indices are demonstrated to collectively identify oscillatory flow disturbances within the flow; quantifying their spatial distribution and influence on the flow field. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Vector Volume Flow in Arteriovenous Fistulas

    DEFF Research Database (Denmark)

    Hansen, Peter Møller; Heerwagen, Søren; Pedersen, Mads Møller

    2013-01-01

    The majority of patients with end stage renal disease are in hemodialysis, and therefore dependent on a well functioning vascular access. The arteriovenous fistula is the recommended access and in order to maintain and keep the fistula patent, regular monitoring of the function is necessary....... The Ultrasound Dilution Technique is the reference method for volume flow measurement, but it only works in conjunction with the dialysis machine, and use is therefore restricted to dialysis sessions. Volume flow measurement with conventional Doppler ultrasound provides a non invasive, highly accessible solution...

  1. An implantable blood pressure and flow transmitter.

    Science.gov (United States)

    Rader, R. D.; Meehan, J. P.; Henriksen, J. K. C.

    1973-01-01

    A miniature totally implantable FM/FM telemetry system has been developed to simultaneously measure blood pressure and blood flow, thus providing an appreciation of the hemodynamics of the circulation to the entire body or to a particular organ. Developed for work with animal subjects, the telemetry system's transmission time is controlled by an RF signal that permits an operating life of several months. Pressure is detected by a miniature intravascular transducer and flow is detected by an extravascular interferometric ultrasonic technique. Both pressure and flow are calibrated prior to implanting. The pressure calibration can be checked after the implanting by cannulation; flow calibration can be verified only at the end of the experiment by determining the voltage output from the implanted sensing system as a function of several measured flow rates. The utility of this device has been established by its use in investigating canine renal circulation during exercise, emotional encounters, administration of drugs, and application of accelerative forces.

  2. Penile blood flow by xenon-133 washout

    Energy Technology Data Exchange (ETDEWEB)

    Haden, H.T.; Katz, P.G.; Mulligan, T.; Zasler, N.D.

    1989-06-01

    Penile erectile failure is often attributed to abnormalities of vascular supply or drainage, but few direct measurements of penile blood flow have been made. We describe the xenon washout method for measurement of penile blood flow, and present the results obtained in a group of normal and impotent subjects. The procedure was performed with standard nuclear imaging equipment. Flaccid-state penile blood flow in the impotent patients studied was not significantly different from the normal group, suggesting that flaccid-state measurements may not be helpful in evaluation of erectile failure. However, this method can be used to measure penile venous outflow with stimulated or induced erection, and may provide a method for detecting abnormal venous leakage.

  3. Use of Small Volume Hypertonic Acetate Dextran during Aortic Occlusion in Pigs: Assessment of Blood Flow and Antioxidant Status in Tissues

    Science.gov (United States)

    2014-01-01

    that HAD was able to buffer against metabolic acidosis in arterial blood Table 2 - Indices of Oxidative Stress in Tissue after Aortic Occlusion and...limited effects on metabolic acidosis reported in other pre-clinical studies, further development of HAD as a resuscitation fluid may not be justified...resuscitation. The premise was that replacing chloride with acetate would reduce the development of hyperchloremic acidosis and supply buffering base to

  4. Subendometrial blood flow changes by 3-dimensional power Doppler ultrasound after hysteroscopic lysis of severe intrauterine adhesions: preliminary study.

    Science.gov (United States)

    Mohamed Amer, Mohamed Ibrahim; Omar, Omar H; El Sherbiny Hamed, Mohamed; Dahroug, Enas G

    2015-01-01

    To evaluate the changes in subendometrial blood flow and endometrial volume after hysteroscopic lysis of severe intrauterine adhesions (IUAs). A pilot observational study. Forty infertile women with severe IUAs served as their own controls and were included in this study only once, to avoid selection bias. Three-dimensional power Doppler ultrasound was performed in all patients 1 day before hysteroscopic lysis of severe IUA, and repeated 1 month later, to assess subendometrial blood flow [as measured by vascularization index (VI), flow index (FI), and vascularization flow index (VFI)] and endometrial volume. Main outcome measures were subendometrial blood flow (VI, FI, VFI) and endometrial volume. There were statistically significant postoperative increases in endometrial volume, VI, FI, and VFI. Subendometrial blood flow improved in 14 women (35%), and menstrual improvement occurred in 15 women (37.5%). Hysteroscopic lysis of severe IUAs improves subendometrial blood flow, with subsequent increases in endometrial volume. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  5. Regulation of blood flow by prostaglandins

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Langberg, H; Risum, N

    2004-01-01

    Prostaglandins (PGs) belong to the family of prostanoids together with thromboxanes and are produced mainly from arachadonic acid by the enzyme cyclooxygenase. PGs are known to stimulate platelet aggregation, mediate inflammation and edema, play a role in bone metabolism and in biological...... adaptation of connective tissues e.g. tendon. This review covers the role of PG for mediating tissue blood flow at rest and during increases in metabolic demand such as exercise and reactive hyperaemia. There is strong evidence that PGs contribute to elevate blood flow at rest and during reactive hyperaemia...

  6. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2003-09-15

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 +- 39.7 ml/min for the right side and 127.6 +- 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 +- 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 +- 59.19 ml/min in male, and 217.28 +- 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  7. Quantitative analysis of normal fetal brain volume and flow by three-dimensional power Doppler ultrasound.

    Science.gov (United States)

    Hsu, Ju-Chun; Wu, Yi-Cheng; Wang, Peng-Hui; Wang, Hsing-I; Juang, Chi-Mou; Chen, Yi-Jen; Chang, Chia-Ming; Horng, Huann-Cheng; Chen, Chih-Yao; Yang, Ming-Jie; Yen, Ming-Shyen; Chao, Kuan-Chong

    2013-09-01

    Assessment of the fetal brain volume and blood flow is important in the evaluation of fetal growth. We used three-dimensional (3D) ultrasound and power Doppler to assess the fetal brain volume and the blood flow index during normal gestation. The relationships of these parameters were further analyzed. We assessed the total volume and the blood flow index of the fetal brain in normal pregnancies using 3D ultrasound (Voluson 730). The bilateral parietal diameter (BPD) plane was measured by a 3D transabdominal probe to scan the fetal brain under the power Doppler mode. Then, we quantitatively assessed the total volume of the fetal brain, mean grey area (MG), vascularization index (VI), flow index (FI), and vascularization-flow index (VFI) by applying Kretz VOCAL software. The study included 126 fetuses, ranging from 15 to 38 weeks of gestation. The total volume of the fetal brain was highly positively correlated with the gestational age (GA) (correlation coefficient [r] = 0.976, p flow development quantitatively. Our study indicates that the fetal brain vascularization and blood flow correlates significantly with the advancement of GA. This information may serve as a reference point for further studies of the fetal brain volume and blood flow in abnormal conditions. Copyright © 2013. Published by Elsevier B.V.

  8. Arterial secondary blood flow patterns visualized with vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Hansen, Jens Munk

    2011-01-01

    and velocity magnitudes the blood flow patterns were visualised with streamlines in Matlab (Mathworks, Natick, MA, USA). The rotational flow was quantified by the angular frequency for each cardiac cycle, and the mean rotational frequencies and standard deviations were calculated for the abdominal aorta f-1......This study presents the first quantification and visualisation of secondary flow patterns with vector flow ultrasound. The first commercial implementation of the vector flow method Transverse Oscillation was used to obtain in-vivo, 2D vector fields in real-time. The hypothesis of this study...... was that the rotational direction is constant within each artery. Three data sets of 10 seconds were obtained from three main arteries in healthy volunteers. For each data set the rotational flow patterns were identified during the diastole. Each data set contains a 2D vector field over time and with the vector angles...

  9. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: I. Theory, error analysis, and stereologic comparison

    DEFF Research Database (Denmark)

    Lida, H; Law, I; Pakkenberg, B

    2000-01-01

    Limited spatial resolution of positron emission tomography (PET) can cause significant underestimation in the observed regional radioactivity concentration (so-called partial volume effect or PVE) resulting in systematic errors in estimating quantitative physiologic parameters. The authors have...... in the corresponding ROIs. Reproducibility of the estimated parameters and sensitivity to various error sources were also evaluated. All models tested in the current study yielded PVE-corrected regional CBF values (approximately 0.8 mL x min(-1) x g(-1) for models with a term for gray matter tissue and 0.5 mL x min(-1...... that included two parallel tissue compartments demonstrated better results with regards to the agreement of tissue time-activity curve and the Akaike's Information Criteria. Error sensitivity analysis suggested the model that fits three parameters of the gray matter CBF, the gray matter fraction, and the white...

  10. Decreased skeletal muscle pump activity in patients with postural tachycardia syndrome and low peripheral blood flow.

    Science.gov (United States)

    Stewart, Julian M; Medow, Marvin S; Montgomery, Leslie D; McLeod, Kenneth

    2004-03-01

    Standing translocates thoracic blood volume into the dependent body. The skeletal muscle pump participates in preventing orthostatic intolerance by enhancing venous return. We investigated the hypothesis that skeletal muscle pump function is impaired in postural tachycardia (POTS) associated with low calf blood flow (low-flow POTS) and depends in general on muscle blood flow. We compared 12 subjects that have low-flow POTS with 10 controls and 7 patients that have POTS and normal calf blood flow using strain-gauge plethysmography to measure peripheral blood flow, venous capacitance, and calf muscle pump function. Blood volume was estimated by dye dilution. We found that calf circumference was reduced in low-flow POTS (32 +/- 1 vs. 39 +/- 3 and 43 +/- 3 cm) and, compared with controls and POTS patients with normal blood flow, is related to the reduced fraction of calf venous capacity emptied during voluntary muscle contraction (ejection fraction, 0.52 +/- 0.07 vs. 0.76 +/- 0.07 and 0.80 +/- 0.06). We found that blood flow was linearly correlated (r(p) = 0.69) with calf circumference (used as a surrogate for muscle mass). Blood volume measurements were 2.2 +/- 0.3 in low-flow POTS vs. 2.6 +/- 0.5 in controls (P = 0.17) and 2.4 +/- 0.7 in normal-flow POTS patients. Decreased calf blood flow may reduce calf size in POTS and thereby impair the upright ejective ability of the skeletal muscle pump and further contribute to overall reduced blood flow and orthostatic intolerance in these patients.

  11. Nonlinear interactions in renal blood flow regulation

    DEFF Research Database (Denmark)

    Marsh, Donald J.; Sosnovtseva, Olga; Chon, Ki H.

    2005-01-01

    resistance and glomerular capillary pressure. The model couples TGF input to voltage-gated Ca channels. It predicts autoregulation of GFR and renal blood flow, matches experimental measures of tubular pressure and macula densa NaCl concentration, and predicts TGF-induced oscillations and a faster smaller...

  12. Frequency encoding in renal blood flow regulation

    DEFF Research Database (Denmark)

    Marsh, D.J.; Sosnovtseva, Olga; Pavlov, A.N.

    2005-01-01

    With a model of renal blood flow regulation, we examined consequences of tubuloglomerular feedback (TGF) coupling to the myogenic mechanism via voltage-gated Ca channels. The model reproduces the characteristic oscillations of the two mechanisms and predicts frequency and amplitude modulation...

  13. Cerebral blood flow in acute mountain sickness

    DEFF Research Database (Denmark)

    Jensen, J B; Wright, Anne; Lassen, N A

    1990-01-01

    Changes in cerebral blood flow (CBF) were measured using the radioactive xenon technique and were related to the development of acute mountain sickness (AMS). In 12 subjects, ascending from 150 to 3,475 m, CBF was 24% increased at 24 h [45.1 to 55.9 initial slope index (ISI) units] and 4% increased...

  14. Blood flow dynamics in the snake spectacle.

    Science.gov (United States)

    van Doorn, Kevin; Sivak, Jacob G

    2013-11-15

    The eyes of snakes are shielded beneath a layer of transparent integument referred to as the 'reptilian spectacle'. Well adapted to vision by virtue of its optical transparency, it nevertheless retains one characteristic of the integument that would otherwise prove detrimental to vision: its vascularity. Given the potential consequence of spectacle blood vessels on visual clarity, one might expect adaptations to have evolved that mitigate their negative impact. Earlier research demonstrated an adaptation to their spatial layout in only one species to reduce the vessels' density in the region serving the foveal and binocular visual fields. Here, we present a study of spectacle blood flow dynamics and provide evidence of a mechanism to mitigate the spectacle blood vessels' deleterious effect on vision by regulation of blood flow through them. It was found that when snakes are at rest and undisturbed, spectacle vessels undergo cycles of dilation and constriction, such that the majority of the time the vessels are fully constricted, effectively removing them from the visual field. When snakes are presented with a visual threat, spectacle vessels constrict and remain constricted for longer periods than occur during the resting cycles, thus guaranteeing the best possible visual capabilities in times of need. Finally, during the snakes' renewal phase when they are generating a new stratum corneum, the resting cycle is abolished, spectacle vessels remain dilated and blood flow remains strong and continuous. The significance of these findings in terms of the visual capabilities and physiology of snakes is discussed.

  15. Influence of Blood Viscosity on Blood Flow and the Effect of Low Molecular Weight Dextran

    Science.gov (United States)

    Dormandy, John A.

    1971-01-01

    Changes in whole blood viscosity are related to changes in the leg blood flow during infusions of low-molecular-weight dextran and Hartmann's solution. A close inverse correlation exists between changes in viscosity and blood flow, the change in blood flow being about three times greater than the change in blood viscosity. The dextran and Hartmann's solution had a similar effect on blood viscosity and blood flow if corrections are made for the difference in haemodilution. PMID:5129616

  16. Mechanical, hormonal and metabolic influences on blood vessels, blood flow and bone.

    Science.gov (United States)

    Prisby, Rhonda D

    2017-12-01

    Bone tissue is highly vascularized due to the various roles bone blood vessels play in bone and bone marrow function. For example, the vascular system is critical for bone development, maintenance and repair and provides O 2 , nutrients, waste elimination, systemic hormones and precursor cells for bone remodeling. Further, bone blood vessels serve as egress and ingress routes for blood and immune cells to and from the bone marrow. It is becoming increasingly clear that the vascular and skeletal systems are intimately linked in metabolic regulation and physiological and pathological processes. This review examines how agents such as mechanical loading, parathyroid hormone, estrogen, vitamin D and calcitonin, all considered anabolic for bone, have tremendous impacts on the bone vasculature. In fact, these agents influence bone blood vessels prior to influencing bone. Further, data reveal strong associations between vasodilator capacity of bone blood vessels and trabecular bone volume, and poor associations between estrogen status and uterine mass and trabecular bone volume. Additionally, this review highlights the importance of the bone microcirculation, particularly the vascular endothelium and NO-mediated signaling, in the regulation of bone blood flow, bone interstitial fluid flow and pressure and the paracrine signaling of bone cells. Finally, the vascular endothelium as a mediator of bone health and disease is considered. © 2017 Society for Endocrinology.

  17. Multimodal measurements of blood plasma and red blood cell volumes during functional brain activation.

    Science.gov (United States)

    Herman, Peter; Sanganahalli, Basavaraju G; Hyder, Fahmeed

    2009-01-01

    As an alternative to functional magnetic resonance imaging (fMRI) with blood oxygenation level dependent (BOLD) contrast, cerebral blood volume (CBV)-weighted fMRI with intravascular contrast agents in animal models have become popular. In this study, dynamic measurements of CBV were performed by magnetic resonance imaging (MRI) and laser-Doppler flowmetry (LDF) in alpha-chloralose anesthetized rats during forepaw stimulation. All recordings were localized to the contralateral primary somatosensory cortex as revealed by BOLD at 11.7 T. Ultra-small superparamagnetic iron oxide (15 mg/kg)--a plasma-borne MRI contrast agent with a half-life of several hours in blood circulation--was used to quantify changes in magnetic field inhomogeneity in blood plasma. The LDF backscattered laser light (805 nm), which reflects the amount of red blood cells, was used to measure alterations in the non-plasma compartment. Dynamic and layer-specific comparisons of the two CBV signals during functional hyperemia revealed excellent correlations (>0.86). These results suggest that CBV measurements from either compartment may be used to reflect dynamic changes in total CBV. Furthermore, by assuming steady-state mass balance and negligible counter flow, these results indicate that volume hematocrit is not appreciably affected during functional activation.

  18. Renal blood flow, early distal sodium, and plasma renin concentrations during osmotic diuresis

    DEFF Research Database (Denmark)

    Leyssac, P P; Holstein-Rathlou, N H; Skøtt, O

    2000-01-01

    .6 mmHg. Urine flow increased 10-fold, and sodium excretion increased by 177%. Plasma renin concentration (PRC) increased by 58%. Renal blood flow and glomerular filtration rate decreased, however end-proximal flow remained unchanged. After a similar volume of hypotonic glucose (152 mM), ED...

  19. Changes in chorioretinal blood flow velocity and cerebral blood flow after carotid endarterectomy.

    Science.gov (United States)

    Enaida, Hiroshi; Nagata, Shinji; Takeda, Atsunobu; Nakao, Shintaro; Ikeda, Yasuhiro; Ishibashi, Tatsuro

    2016-11-01

    To investigate the changes in chorioretinal blood flow velocity and cerebral blood after carotid endarterectomy (CEA). Nine patients with moderate to severe internal carotid artery stenosis underwent CEA. Chorioretinal blood flow velocity was measured by laser speckle flowgraphy (LSFG), while cerebral blood flow (CBF) was measured by single-photon emission computed tomography (SPECT), on the affected side both before and after CEA. LSFG was evaluated in five areas to determine mean blur rate, while CBF was calculated from regional CBF and cerebrovascular reactivity (CVR), at the middle cerebral artery (MCA) region of each patient. Five cases showed an increase (mean 3.49 %, range -29.82 to 35.59 %) of average chorioretinal blood flow velocity using LSFG after CEA. A particularly averaged increase in chorioretinal blood flow was observed in the macular area compared with other areas. Similarly, there was an increase in CBF at rest (mean 11.46 %, range -14.51 to 74.14 %) observed using SPECT after surgery. Improvement of CVR was confirmed in four cases. All general and visual symptoms disappeared after CEA. Severe adverse effects, including hyperperfusion syndrome, were not observed in any cases. LSFG may be useful for the analysis of chorioretinal blood flow changes after CEA.

  20. In vivo analysis of physiological 3D blood flow of cerebral veins.

    Science.gov (United States)

    Schuchardt, Florian; Schroeder, Laure; Anastasopoulos, Constantin; Markl, Michael; Bäuerle, Jochen; Hennemuth, Anja; Drexl, Johann; Valdueza, José M; Mader, Irina; Harloff, Andreas

    2015-08-01

    To visualize and quantify physiological blood flow of intracranial veins in vivo using time-resolved, 3D phase-contrast MRI (4D flow MRI), and to test measurement accuracy. Fifteen healthy volunteers underwent repeated ECG-triggered 4D flow MRI (3 Tesla, 32-channel head coil). Intracranial venous blood flow was analysed using dedicated software allowing for blood flow visualization and quantification in analysis planes at the superior sagittal, straight, and transverse sinuses. MRI was evaluated for intra- and inter-observer agreement and scan-rescan reproducibility. Measurements of the transverse sinuses were compared with transcranial two-dimensional duplex ultrasound. Visualization of 3D blood flow within cerebral sinuses was feasible in 100 % and within at least one deep cerebral vein in 87 % of the volunteers. Blood flow velocity/volume increased along the superior sagittal sinus and was lower in the left compared to the right transverse sinus. Intra- and inter-observer reliability and reproducibility of blood flow velocity (mean difference 0.01/0.02/0.02 m/s) and volume (mean difference 0.0002/-0.0003/0.00003 l/s) were good to excellent. High/low velocities were more pronounced (8 % overestimation/9 % underestimation) in MRI compared to ultrasound. Four-dimensional flow MRI reliably visualizes and quantifies three-dimensional cerebral venous blood flow in vivo and is promising for studies in patients with sinus thrombosis and related diseases. • 4D flow MRI can be used to visualize and quantify physiological cerebral venous haemodynamics • Flow quantification within cerebral sinuses reveals high reliability and accuracy of 4D flow MRI • Blood flow volume and velocity increase along the superior sagittal sinus • Limited spatial resolution currently precludes flow quantification in small cerebral veins.

  1. Cerebral blood flow tomography with xenon-133

    DEFF Research Database (Denmark)

    Lassen, N A

    1985-01-01

    Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-133. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission...... of other tracers for CBF tomography using SPECT is summarized with emphasis on the 99mTc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers....

  2. Brain blood-flow changes during motion sickness. [thalamus vascular changes in dogs during swing tests

    Science.gov (United States)

    Johnson, W. H.; Hsuen, J.

    1973-01-01

    The possibility of diminished blood flow in the brain is studied as one of the factors resulting from an increase in skeletal muscle blood volume concomitant with other characteristics of motion sickness. Thermistors are implanted in the thalamus of dogs and blood flow changes are recorded while they are subjected to sinusoidal movement on a two pole swing. Results of these initial steps in a proposed long term exploration of different areas of the brain are presented.

  3. Post-mortem virtual estimation of free abdominal blood volume.

    Science.gov (United States)

    Ampanozi, Garyfalia; Hatch, Gary M; Ruder, Thomas D; Flach, Patricia M; Germerott, Tanja; Thali, Michael J; Ebert, Lars C

    2012-09-01

    The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. Post-mortem virtual estimation of free abdominal blood volume

    Energy Technology Data Exchange (ETDEWEB)

    Ampanozi, Garyfalia, E-mail: garyfalia.ampanozi@irm.uzh.ch [Center of Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, CH 3012 Bern (Switzerland); Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, CH 8057 Zurich (Switzerland); Hatch, Gary M. [Center of Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, CH 3012 Bern (Switzerland); Ruder, Thomas D. [Center of Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, CH 3012 Bern (Switzerland); Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, CH 8057 Zurich (Switzerland); Flach, Patricia M. [Center of Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, CH 3012 Bern (Switzerland); Department of Radiology, University Hospital of Zurich, Zurich (Switzerland); Germerott, Tanja [Center of Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, CH 3012 Bern (Switzerland); Thali, Michael J. [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, CH 8057 Zurich (Switzerland); Ebert, Lars C. [Center of Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, CH 3012 Bern (Switzerland); Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, CH 8057 Zurich (Switzerland)

    2012-09-15

    Purpose: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. Materials and methods: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). Results: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. Conclusion: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed.

  5. Glial and neuronal control of brain blood flow

    DEFF Research Database (Denmark)

    Attwell, David; Buchan, Alastair M; Charpak, Serge

    2010-01-01

    Blood flow in the brain is regulated by neurons and astrocytes. Knowledge of how these cells control blood flow is crucial for understanding how neural computation is powered, for interpreting functional imaging scans of brains, and for developing treatments for neurological disorders. It is now...... recognized that neurotransmitter-mediated signalling has a key role in regulating cerebral blood flow, that much of this control is mediated by astrocytes, that oxygen modulates blood flow regulation, and that blood flow may be controlled by capillaries as well as by arterioles. These conceptual shifts...... in our understanding of cerebral blood flow control have important implications for the development of new therapeutic approaches....

  6. Cerebral autoregulation control of blood flow in the brain

    CERN Document Server

    Payne, Stephen

    2016-01-01

    This Brief provides a comprehensive introduction to the control of blood flow in the brain. Beginning with the basic physiology of autoregulation, the author goes on to discuss measurement techniques, mathematical models, methods of analysis, and relevant clinical conditions, all within this single volume. The author draws together this disparate field, and lays the groundwork for future research directions. The text gives an up-to-date review of the state of the art in cerebral autoregulation, which is particularly relevant as cerebral autoregulation moves from the laboratory to the bedside. Cerebral Autoregulation will be useful to researchers in the physical sciences such as mathematical biology, medical physics, and biomedical engineering whose work is concerned with the brain. Researchers in the medical sciences and clinicians dealing with the brain and blood flow, as well as industry professionals developing techniques such as ultrasound, MRI, and CT will also find this Brief of interest.

  7. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Bendtsen, Flemming; Henriksen, Jens Henrik

    1995-01-01

    BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...... and in controls. METHODS: Thirty-nine patients with cirrhosis (12 patients with Child-Turcotte class A, 14 with class B, and 13 with class C) and 6 controls were studied. During hepatic vein catheterization, cardiac output, systemic vascular resistance, central and arterial blood volume, noncentral blood volume...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly...

  8. Femoral Blood Flow and Cardiac Output During Blood Flow Restricted Leg Press Exercise

    Science.gov (United States)

    Everett, M. E.; Hackney, K.; Ploutz-Snyder, L.

    2011-01-01

    Low load blood flow restricted resistance exercise (LBFR) causes muscle hypertrophy that may be stimulated by the local ischemic environment created by the cuff pressure. However, local blood flow (BF) during such exercise is not well understood. PURPOSE: To characterize femoral artery BF and cardiac output (CO) during leg press exercise (LP) performed at a high load (HL) and low load (LL) with different levels of cuff pressure. METHODS: Eleven subjects (men/women 4/7, age 31.4+/-12.8 y, weight 68.9+/-13.2 kg, mean+/-SD) performed 3 sets of supine left LP to fatigue with 90 s of rest in 4 conditions: HL (%1-RM/cuff pressure: 80%/0); LL (20%/0); LBFR(sub DBP) (20%/1.3 x diastolic blood pressure, BP); LBFR(sub SBP) (20%/1.3 x supine systolic BP). The cuff remained inflated throughout the LBFR exercise sessions. Artery diameter, velocity time integral (VTI), and stroke volume (SV) were measured using Doppler ultrasound at rest and immediately after each set of exercise. Heart rate (HR) was monitored using a 3-lead ECG. BF was calculated as VTI x vessel cross-sectional area. CO was calculated as HR x SV. The data obtained after each set of exercise were averaged and used for analyses. Multi-level modeling was used to determine the effect of exercise condition on dependent variables. Statistical significance was set a priori at p LL (9.92+/-0.82 cm3) > LBFR(sub dBP)(6.47+/-0.79 cm3) > LBFR(sub SBP) (3.51+/-0.59 cm3). Blunted exercise induced increases occurred in HR, SV, and CO after LBFR compared to HL and LL. HR increased 45% after HL and LL and 28% after LBFR (p<0.05), but SV increased (p<0.05) only after HL. Consequently, the increase (p<0.05) in CO was greater in HL and LL (approximately 3 L/min) than in LBFR (approximately 1 L/min). CONCLUSION: BF during LBFR(sub SBP) was 1/3 of that observed in LL, which supports the hypothesis that local ischemia stimulates the LBFR hypertrophic response. As the cuff did not compress the artery, the ischemia may have occurred

  9. In vivo analysis of physiological 3D blood flow of cerebral veins

    Energy Technology Data Exchange (ETDEWEB)

    Schuchardt, Florian; Schroeder, Laure; Baeuerle, Jochen; Harloff, Andreas [University Medical Centre, Department of Neurology, Freiburg (Germany); Anastasopoulos, Constantin [University Medical Center, Department of Neuropaediatrics and Muscle Disorders, Freiburg (Germany); University Medical Centre, Department of Neuroradiology, Freiburg (Germany); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine and McCormick School of Engineering, Chicago, IL (United States); Hennemuth, Anja; Drexl, Johann [Fraunhofer MEVIS, Bremen (Germany); Valdueza, Jose M. [Neurological Center, Segeberger Kliniken, Bad Segeberg (Germany); Mader, Irina [University Medical Centre, Department of Neuroradiology, Freiburg (Germany)

    2015-08-15

    To visualize and quantify physiological blood flow of intracranial veins in vivo using time-resolved, 3D phase-contrast MRI (4D flow MRI), and to test measurement accuracy. Fifteen healthy volunteers underwent repeated ECG-triggered 4D flow MRI (3 Tesla, 32-channel head coil). Intracranial venous blood flow was analysed using dedicated software allowing for blood flow visualization and quantification in analysis planes at the superior sagittal, straight, and transverse sinuses. MRI was evaluated for intra- and inter-observer agreement and scan-rescan reproducibility. Measurements of the transverse sinuses were compared with transcranial two-dimensional duplex ultrasound. Visualization of 3D blood flow within cerebral sinuses was feasible in 100 % and within at least one deep cerebral vein in 87 % of the volunteers. Blood flow velocity/volume increased along the superior sagittal sinus and was lower in the left compared to the right transverse sinus. Intra- and inter-observer reliability and reproducibility of blood flow velocity (mean difference 0.01/0.02/0.02 m/s) and volume (mean difference 0.0002/-0.0003/0.00003 l/s) were good to excellent. High/low velocities were more pronounced (8 % overestimation/9 % underestimation) in MRI compared to ultrasound. Four-dimensional flow MRI reliably visualizes and quantifies three-dimensional cerebral venous blood flow in vivo and is promising for studies in patients with sinus thrombosis and related diseases. (orig.)

  10. Red blood cell in simple shear flow

    Science.gov (United States)

    Chien, Wei; Hew, Yayu; Chen, Yeng-Long

    2013-03-01

    The dynamics of red blood cells (RBC) in blood flow is critical for oxygen transport, and it also influences inflammation (white blood cells), thrombosis (platelets), and circulatory tumor migration. The physical properties of a RBC can be captured by modeling RBC as lipid membrane linked to a cytoskeletal spectrin network that encapsulates cytoplasm rich in hemoglobin, with bi-concave equilibrium shape. Depending on the shear force, RBC elasticity, membrane viscosity, and cytoplasm viscosity, RBC can undergo tumbling, tank-treading, or oscillatory motion. We investigate the dynamic state diagram of RBC in shear and pressure-driven flow using a combined immersed boundary-lattice Boltzmann method with a multi-scale RBC model that accurately captures the experimentally established RBC force-deformation relation. It is found that the tumbling (TU) to tank-treading (TT) transition occurs as shear rate increases for cytoplasm/outer fluid viscosity ratio smaller than 0.67. The TU frequency is found to be half of the TT frequency, in agreement with experiment observations. Larger viscosity ratios lead to the disappearance of stable TT phase and unstable complex dynamics, including the oscillation of the symmetry axis of the bi-concave shape perpendicular to the flow direction. The dependence on RBC bending rigidity, shear modulus, the order of membrane spectrin network and fluid field in the unstable region will also be discussed.

  11. Newly developed circulating blood volume-monitoring system and its clinical application for measuring changes in blood volume during hemofiltration.

    Science.gov (United States)

    Maeda, K; Shinzato, T; Yoshida, F; Tsuruta, Y; Usuda, M; Yamada, K; Ishihara, T; Inagaki, F; Igarashi, I; Kitano, T

    1986-12-01

    Blood and ultrafiltrate electrical resistivities were continuously monitored during hemofiltration. By substituting these values into a previously developed equation that was modified by the authors, the hematocrit value was determined; and blood volume change was obtained from the change in this value. The following facts were discovered as the result of monitoring the blood volume change during treatment: When the body position was changed from the reclining to the sitting position, the blood volume decreased by 4.2 +/- 0.3%. With the body water removal rate kept constant, the body position recumbent, and the subject fasted, the blood volume gradually decreased. However, when the position was changed from reclining to sitting for food intake and once more returned to the supine position after the meal, the blood volume was greatly affected by the change in position and the food intake.

  12. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients.

    Science.gov (United States)

    Kamran, Mudassar; Byrne, James V

    2015-09-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31%) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91% sensitive and 100% specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (≈ 60% blood flow and ≈ 40% blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (≈ 60%) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia.

  13. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, Mudassar; Byrne, James V. [University of Oxford, Nuffield Department of Surgical Sciences, Oxford (United Kingdom)

    2015-09-15

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  14. Accurate Blood Flow Measurements : Are Artificial Tracers Necessary?

    NARCIS (Netherlands)

    Poelma, C.; Kloosterman, A.; Hierck, B.P.; Westerweel, J.

    2012-01-01

    Imaging-based blood flow measurement techniques, such as particle image velocimetry, have become an important tool in cardiovascular research. They provide quantitative information about blood flow, which benefits applications ranging from developmental biology to tumor perfusion studies. Studies

  15. Measuring blood pressure in mice using volume pressure recording, a tail-cuff method.

    Science.gov (United States)

    Daugherty, Alan; Rateri, Debra; Hong, Lu; Balakrishnan, Anju

    2009-05-15

    The CODA 8-Channel High Throughput Non-Invasive Blood Pressure system measures the blood pressure in up to 8 mice or rats simultaneously. The CODA tail-cuff system uses Volume Pressure Recording (VPR) to measure the blood pressure by determining the tail blood volume. A specially designed differential pressure transducer and an occlusion tail-cuff measure the total blood volume in the tail without the need to obtain the individual pulse signal. Special attention is afforded to the length of the occlusion cuff in order to derive the most accurate blood pressure readings. VPR can easily obtain readings on dark-skinned rodents, such as C57BL6 mice and is MRI compatible. The CODA system provides you with measurements of six (6) different blood pressure parameters; systolic and diastolic blood pressure, heart rate, mean blood pressure, tail blood flow, and tail blood volume. Measurements can be made on either awake or anesthetized mice or rats. The CODA system includes a controller, laptop computer, software, cuffs, animal holders, infrared warming pads, and an infrared thermometer. There are seven different holder sizes for mice as small as 8 grams to rats as large as 900 grams.

  16. Modified Numerical Simulation Model of Blood Flow in Bend.

    Science.gov (United States)

    Liu, X; Zhou, X; Hao, X; Sang, X

    2015-12-01

    The numerical simulation model of blood flow in bend is studied in this paper. The curvature modification is conducted for the blood flow model in bend to obtain the modified blood flow model in bend. The modified model is verified by U tube. By comparing the simulation results with the experimental results obtained by measuring the flow data in U tube, it was found that the modified blood flow model in bend can effectively improve the prediction accuracy of blood flow data affected by the curvature effect.

  17. Regional cerebral blood flow in childhood headache

    Energy Technology Data Exchange (ETDEWEB)

    Roach, E.S.; Stump, D.A.

    1989-06-01

    Regional cerebral blood flow (rCBF) was measured in 16 cranial regions in 23 children and adolescents with frequent headaches using the non-invasive Xenon-133 inhalation technique. Blood flow response to 5% carbon dioxide (CO2) was also determined in 21 patients, while response to 50% oxygen was measured in the two patients with hemoglobinopathy. Included were 10 patients with a clinical diagnosis of migraine, 4 with musculoskeletal headaches, and 3 with features of both types. Also studied were 2 patients with primary thrombocythemia, 2 patients with hemoglobinopathy and headaches, 1 patient with polycythemia, and 1 with headaches following trauma. With two exceptions, rCBF determinations were done during an asymptomatic period. Baseline rCBF values tended to be higher in these young patients than in young adults done in our laboratory. Localized reduction in the expected blood flow surge after CO2 inhalation, most often noted posteriorly, was seen in 8 of the 13 vascular headaches, but in none of the musculoskeletal headache group. Both patients with primary thrombocythemia had normal baseline flow values and altered responsiveness to CO2 similar to that seen in migraineurs; thus, the frequently reported headache and transient neurologic signs with primary thrombocythemia are probably not due to microvascular obstruction as previously suggested. These data support the concept of pediatric migraine as a disorder of vasomotor function and also add to our knowledge of normal rCBF values in younger patients. Demonstration of altered vasomotor reactivity to CO2 could prove helpful in children whose headache is atypical.

  18. Estimation of hepatic blood flow by hydrogen gas clearance

    NARCIS (Netherlands)

    Gouma, D. J.; Coelho, J. C.; Schlegel, J.; Fisher, J. D.; Li, Y. F.; Moody, F. G.

    1986-01-01

    The hydrogen gas clearance technique was evaluated to estimate regional hepatic blood flow. Initially, the H2 gas method was compared to the indocyanine green clearance in mini pigs. The blood flow measured by the H2 gas method (0.49 +/- 0.03 ml/min/gm) was only 39% of the calculated blood flow by

  19. Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements.

    Science.gov (United States)

    Ma, Irene W Y; Caplin, Joshua D; Azad, Aftab; Wilson, Christina; Fifer, Michael A; Bagchi, Aranya; Liteplo, Andrew S; Noble, Vicki E

    2017-12-01

    Non-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid blood flow) and their correlations with invasive reference measurements of cardiac output. Consenting adult patients (n = 51) at Massachusetts General Hospital cardiac catheterization laboratory undergoing right heart catheterization between February and April 2016 were included. Carotid ultrasound images were obtained concurrently with cardiac output measurements, obtained by the thermodilution method in the absence of severe tricuspid regurgitation and by the Fick oxygen method otherwise. Corrected carotid flow time was calculated as systole time/√cycle time. Carotid blood flow was calculated as π × (carotid diameter)2/4 × velocity time integral × heart rate. Measurements were obtained using a single carotid waveform and an average of three carotid waveforms for both measures. Single waveform measurements of corrected flow time did not correlate with cardiac output (ρ = 0.25, 95% CI -0.03 to 0.49, p = 0.08), but an average of three waveforms correlated significantly, although weakly (ρ = 0.29, 95% CI 0.02-0.53, p = 0.046). Carotid blood flow measurements correlated moderately with cardiac output regardless of if single waveform or an average of three waveforms were used: ρ = 0.44, 95% CI 0.18-0.63, p = 0.004, and ρ = 0.41, 95% CI 0.16-0.62, p = 0.004, respectively. Carotid blood flow may be a better marker of cardiac output and less subject to measurements issues than corrected carotid flow time.

  20. Decorrelation-based blood flow velocity estimation: effect of spread of flow velocity, linear flow velocity gradients, and parabolic flow.

    NARCIS (Netherlands)

    Lupotti, F.A.; Steen, A.F.W. van der; Mastik, F.; Korte, C.L. de

    2002-01-01

    In recent years, a new method to measure transverse blood flow, based on the decorrelation of the radio frequency (RF) signals has been developed. In this paper, we investigated the influence of nonuniform flow on the velocity estimation. The decorrelation characteristics of transverse blood flow

  1. Bolus arrival time and cerebral blood flow responses to hypercarbia.

    Science.gov (United States)

    Donahue, Manus J; Faraco, Carlos C; Strother, Megan K; Chappell, Michael A; Rane, Swati; Dethrage, Lindsey M; Hendrikse, Jeroen; Siero, Jeroen C W

    2014-07-01

    The purpose of this study was to evaluate how cerebral blood flow and bolus arrival time (BAT) measures derived from arterial spin labeling (ASL) MRI data change for different hypercarbic gas stimuli. Pseudocontinuous ASL (pCASL) was applied (3.0T; spatial resolution=4 × 4 × 7 mm(3); repetition time/echo time (TR/TE)=3,600/11 ms) sequentially in healthy volunteers (n=12; age=30±4 years) for separate experiments in which (i) normocarbic normoxia (i.e., room air), hypercarbic normoxia (i.e., 5% CO₂/21% O₂/74% N2), and hypercarbic hyperoxia (i.e., carbogen: 5% CO₂/95% O₂) gas was administered (12 L/minute). Cerebral blood flow and BAT changes were quantified using models that account for macrovascular signal and partial volume effects in all gray matter and regionally in cerebellar, temporal, occipital, frontal, and parietal lobes. Regional reductions in BAT of 4.6% to 7.7% and 3.3% to 6.6% were found in response to hypercarbic normoxia and hypercarbic hyperoxia, respectively. Cerebral blood flow increased by 8.2% to 27.8% and 3.5% to 19.8% for hypercarbic normoxia and hypercarbic hyperoxia, respectively. These findings indicate that changes in BAT values may bias functional ASL data and thus should be considered when choosing appropriate experimental parameters in calibrated functional magnetic resonance imaging or ASL cerebrovascular reactivity experiments that use hypercarbic gas stimuli.

  2. Skin blood flow changes during apneic spells in preterm infants

    NARCIS (Netherlands)

    Suichies, H.E.; Aarnoudse, J.G.; Okken, A.; Jentink, H.W.; de Mul, F.F.M.; Greve, Jan

    1989-01-01

    Changes in skin blood flow during apneic spells were determined in 18 preterm infants using a diode laser Doppler flow meter without light conducting fibres. Heart rate, nasal air flow, impedance pneumography, skin and incubator temperature and laser Doppler skin blood flow were recorded

  3. Blood flow in healed and inflamed periodontal tissues of dogs

    Energy Technology Data Exchange (ETDEWEB)

    Hock, J.M.; Kim, S.

    1987-01-01

    The objectives of this study were to determine if increased blood flow associated with gingivitis would decrease following resolution of gingival inflammation in dogs with periodontitis; if increased blood flow in inflamed gingiva was associated with changes in the blood flow of alveolar bone, and if blood flow in gingiva and alveolar bone increased if periodontitis was reactivated by ligating teeth. Regional blood flow was measured in dogs with pre-existing periodontitis, using radioisotope-labelled, plastic microspheres. In the first experiment on 4 adult Beagle dogs, teeth in the left jaws were treated to resolve the periodontitis, while teeth in the right jaws were not treated. Gingival and bone blood flow were measured after 12 wk. Blood flow was significantly (p<0.05) lower in non-inflamed healed gingiva (32.1 +- 2.7 ml/min/100 g) than in inflamed gingiva (46.1 +- 5.3 ml/min/100 g). No differences in the blood flow of the alveolar bone underlying inflamed or non-inflamed gingiva were present. In the second experiment, the right mandibular teeth of 5 dogs were treated to resolve periodontitis while teeth in the other quadrants were ligated for 4, 10 or 12 wk. The duration of ligation did not alter blood flow. Gingival blood flow around ligated maxillary and mandibular teeth was comparable and approximately 54% higher than around non-ligated teeth (p<0.03). The difference in blood flow between gingiva with G.I.>1 and gingiva with G.I.<2 was significant (p<0.04). Blood flow in bone was not altered by changes in the inflammatory status of the overlying gingiva. The findings suggest that changes in blood flow associated with inflammation are reversible and that blood flow alveolar bone is regulated independently of gingival blood flow.

  4. Topical menthol increases cutaneous blood flow.

    Science.gov (United States)

    Craighead, Daniel H; Alexander, Lacy M

    2016-09-01

    Menthol, the active ingredient in several topically applied analgesics, activates transient receptor potential melastatin 8 (TRPM8) receptors on sensory nerves and on the vasculature inducing a cooling sensation on the skin. Ilex paraguariensis is also a common ingredient in topical analgesics that has potential vasoactive properties and may alter the mechanisms of action of menthol. We sought to characterize the microvascular effects of topical menthol and ilex application and to determine the mechanism(s) through which these compounds may independently and combined alter cutaneous blood flow. We hypothesized that menthol would induce vasoconstriction and that ilex would not alter skin blood flow (SkBF). Three separate protocols were conducted to examine menthol and ilex-mediated changes in SkBF. In protocol 1, placebo, 4% menthol, 0.7% ilex, and combination menthol+ilex gels were applied separately to the skin and red cell flux was continuously measured utilizing laser speckle contrast imaging (LSCI). In protocol 2, seven concentrations of menthol gel (0.04%, 0.4%, 1%, 2%, 4%, 7%, 8%) were applied to the skin to model the dose-response curve. In protocol 3, placebo, menthol, ilex, and menthol+ilex gels were applied to skin under local thermal control (34°C) both with and without sensory nerve blockage (topical lidocaine 4%). Post-occlusive reactive hyperemia (PORH) and local heating (42°C) protocols were conducted to determine the relative contribution of endothelium derived hyperpolarizing factors (EDHFs)/sensory nerves and nitric oxide (NO), respectively. Red cell flux was normalized to mean arterial pressure expressed as cutaneous vascular conductance (CVC: flux·mmHg(-1)) in all protocols. Topical menthol application increased SkBF compared to placebo (3.41±0.33 vs 1.1±0.19CVC: pmenthol (main effect, pmenthol application during PORH (3.62±0.29 vs. 2.50±0.21flux·mmHg(-1); pmenthol-mediated vasodilation at thermoneutral baseline (1.29±0.19flux·mmHg(-1

  5. Micro-PIV quantification of capillary blood flow redistribution caused by laser-assisted vascular occlusion

    Science.gov (United States)

    Kurochkin, Maxim A.; Stiukhina, Elena S.; Fedosov, Ivan V.; Postnov, Dmitry E.; Tuchin, Valery V.

    2016-04-01

    We propose μPIV-based technique for quantitative assessment of blood flow redistribution in microcirculatory networks. Our approach is based on per-segment averaging of measured quantities so we can avoid most of problems that are typical for point-wise measurements. The key point of our technique is the digital processing algorithms of recorded data that include: capillary network axial line construction; interrogation regions centering; blood flow velocity local estimate using PIV approach; blood flow velocity calculation by means of averaging over entire vessel segment; the calculation of blood volume flow rate map. We illustrate the application of developed technique with in vivo measurements and blood flow velocity map reconstruction for chorioallantoic membrane (CAM) of chicken embryo, in which the local vascular occlusion was produced using continuous wave laser light irradiation..

  6. Capillary pericytes regulate cerebral blood flow in health and disease

    DEFF Research Database (Denmark)

    Hall, Catherine N; Reynell, Clare; Gesslein, Bodil

    2014-01-01

    Increases in brain blood flow, evoked by neuronal activity, power neural computation and form the basis of BOLD (blood-oxygen-level-dependent) functional imaging. Whether blood flow is controlled solely by arteriole smooth muscle, or also by capillary pericytes, is controversial. We demonstrate...... blood flow, capillaries dilate before arterioles and are estimated to produce 84% of the blood flow increase. In pathology, ischaemia evokes capillary constriction by pericytes. We show that this is followed by pericyte death in rigor, which may irreversibly constrict capillaries and damage the blood......-brain barrier. Thus, pericytes are major regulators of cerebral blood flow and initiators of functional imaging signals. Prevention of pericyte constriction and death may reduce the long-lasting blood flow decrease that damages neurons after stroke....

  7. Intramuscular blood flow quantification with power doppler ultrasonography.

    Science.gov (United States)

    Dori, Amir; Abbasi, Hiba; Zaidman, Craig M

    2016-11-01

    Quantification of blood flow to muscle using ultrasound is limited to large vessels. Small vessel intramuscular blood flow cannot be quantified using ultrasound without specialized methods or intravenous contrast. We describe a technique using power Doppler to quantify postcontraction hyperemia in intramuscular vessels that can be used at the bedside. In 11 healthy subjects, postcontraction intramuscular blood flow in the forearm flexors and tibialis anterior muscles increased with stronger and repeated contractions. Intravascular blood flow measured by pulsed Doppler in the brachial artery similarly increased. Three patients with muscular dystrophies showed a negligible increase of postcontraction intramuscular blood flow. Intramuscular blood flow can be quantified using power Doppler ultrasonography; it increases following contraction and may be reduced in patients with muscular dystrophies. This quantitative, noninvasive technique can be applied at the bedside and may facilitate studies of disease impact on intramuscular blood flow. Muscle Nerve 54: 872-878, 2016. © 2016 Wiley Periodicals, Inc.

  8. Cerebral blood flow tomography with xenon-133

    Energy Technology Data Exchange (ETDEWEB)

    Lassen, N.A.

    1985-10-01

    Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-/sup 133/. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission computed tomograph (SPECT) is required. Two brain-dedicated SPECT systems designed for this purpose are mentioned, and the method is described with special reference to the limitations inherent in the soft energy of the 133Xe primary photons. CBF tomography can be used for a multitude of clinical and investigative purposes. This article discusses in particular its use for the selection of patients with carotid occlusion for extracranial/intracranial bypass surgery, for detection of severe arterial spasm after aneurysm bleeding, and for detection of low flow areas during severe migraine attacks. The use of other tracers for CBF tomography using SPECT is summarized with emphasis on the /sup 99m/Tc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers.

  9. The effect of hyperosmotic solutions on the hepatic blood flow

    DEFF Research Database (Denmark)

    Winkler, K; Henriksen, Jens Henrik Sahl; Tygstrup, N

    1993-01-01

    The present study was undertaken in order to measure the effect of hyperosmotic solutions on portal and hepatic blood flow. In five anaesthetized pigs without arterial blood supply to the liver, portal blood flow rate was measured (electromagnetic flowmeter) during 5 min lasting intravenous...... for these osmotic effects are not known, but they have to be taken into consideration in studies of the portal and hepatic blood flow....

  10. Blood Volume: Importance and Adaptations to Exercise Training, Environmental Stresses and Trauma Sickness

    Science.gov (United States)

    2000-02-01

    drinking water/glycerol solutions (90,91) and subsequently exercised in the heat. Albumin infusion expanded plasma volume by ;13% above control levels. In...heat (21,42,43,108). Studies (43,108) have demonstrated that isotonic hypohydration reduces skin blood flow for a given core temperature and therefore...mechanisms for plasma volume reduction during altitude acclimatization remain unresolved. Dehydration from drinking insufficient fluid to offset urinary

  11. Doppler sonographic evaluation of the digital blood flow in horses with laminitis or septic pododermatitis.

    Science.gov (United States)

    Wongaumnuaykul, Santi; Siedler, Claudia; Schobesberger, Hermann; Stanek, Christian

    2006-01-01

    The aim of this study was to evaluate the use of Doppler ultrasonography to monitor vascular blood flow dynamics in defined diseases of the equine digit in a noninvasive way. Doppler sonography was used to evaluate medial digital artery blood flow in eight horses with septic pododermatitis and four horses with laminitis in comparison with 10 horses of a control group. Doppler sonographic measurement and lameness examinations were performed in lame horses before treatment (day 0) and at 3, 6, and 9 days following treatment. Before treatment, blood flow velocities, arterial diameter, and flow volume were significantly higher in the lame horses, while pulsatility indices (PIs) were significantly lower (P pododermatitis group, but these indices were significantly lower in the laminitis group. No significant difference between the two lame groups was recorded. After treatment, blood flow velocities and flow volume decreased significantly and PIs increased significantly in both lame groups, while RI and arterial diameter did not change. No correlation between Doppler parameters and the degree of lameness was found. Doppler sonography can be used to monitor vascular blood flow dynamics in horses suffering from septic pododermatitis and laminitis, while blood flow velocities and PI can serve as parameters for monitoring the course of the disease.

  12. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    and in controls. METHODS: Thirty-nine patients with cirrhosis (12 patients with Child-Turcotte class A, 14 with class B, and 13 with class C) and 6 controls were studied. During hepatic vein catheterization, cardiac output, systemic vascular resistance, central and arterial blood volume, noncentral blood volume...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly....... CONCLUSIONS: Only in mild cirrhosis is the effective blood volume able to increase in response to volume expansion. Our results are consistent with the peripheral vasodilatation hypothesis and the circulatory hyporeactivity occurring in advanced cirrhosis....

  13. Blood Volume Response to Physical Activity and Inactivity

    Science.gov (United States)

    2007-07-01

    deconditioning effects of bed rest inactivity are independent of any disease state. The impor- tance of physical activity on reversing the effects of inactivity...Blood Volume Response to Physical Activity and Inactivity VICTOR A. CONVERTINO, PHD ABSTRACT: Data from both cross-sectional and longitu- dinal...studies provide compelling evidence that circulat- ing blood volume can be influenced by regular physical activity or inactivity. Expansion or contraction

  14. Regulation of Colonic Mucosal Blood Flow by Exogenous Ecosanoids in the Rat

    OpenAIRE

    Yoshida, Noboru; Makiyama, Kazuya; Hoshiko, Tatsuhide

    1994-01-01

    We measured colonic mucosal blood flow using a reflectance spectrophotometry in Wistar rats during and after continuous injection of prostaglandins (PGs: PGE1, PGE2 and PGI2), as vasodilators, and thromboxane A2 (TXA2) as a vasoconstrictor. Administration of PGs increased colonic mucosal blood volume and oxyhemoglobin saturation of the colonic mucosal tissue, representing a parameter of mucosal oxygenation. The dose used did not change arterial blood pressure. These results suggest that PGs r...

  15. Retinal blood flow measurements and neuroretinal rim damage in glaucoma

    Science.gov (United States)

    Logan, J F J; Rankin, S J A; Jackson, A J

    2004-01-01

    Aim: To assess retinal blood flow characteristics in subjects with normal tension glaucoma (NTG), primary open angle glaucoma (POAG), and a group of controls using the Heidelberg retina flowmeter (HRF). The vascular parameters were correlated against structural damage of the optic nerve head, assessed using the Heidelberg retina tomograph (HRT). Methods: HRF images were obtained in 76 subjects with NTG, 58 with POAG, and 38 controls. Optic nerve head images, acquired using the HRT, were analysed with Moorfields Regression Analysis software. The HRF variables, measured adjacent to a rim segment identified as “abnormal,” were compared with the vascular parameters of the “normal” rim segments. The HRF parameters of the segments identified as normal in glaucoma subjects were compared with matched control segments. Results: The glaucoma subjects had significantly lower retinal haemodynamics than the control subjects. There were no significant differences in the HRF parameters between the NTG and POAG subjects. The discs that had been identified as having abnormal segments had lower HRF values than those with a corresponding normal segment. The glaucoma subjects with normal rim segments had statistically significant lower velocity, flow, and volume measurements than the controls for each location sampled. Conclusion: This study shows a relation between structural damage of the optic nerve head and the level of retinal blood flow. The changes in the circulation could indicate that it may be an early marker of the pathological process. PMID:15258023

  16. The measurement of peripheral blood volume reactions to tilt test by the electrical impedance technique after exercise in athletes

    Science.gov (United States)

    Melnikov, A. A.; Popov, S. G.; Nikolaev, D. V.; Vikulov, A. D.

    2013-04-01

    We have investigated the distribution of peripheral blood volumes in different regions of the body in response to the tilt-test in endurance trained athletes after aerobic exercise. Distribution of peripheral blood volumes (ml/beat) simultaneously in six regions of the body (two legs, two hands, abdomen, neck and ECG) was assessed in response to the tilt-test using the impedance method (the impedance change rate (dZ/dT). Before and after exercise session cardiac stroke (CSV) and blood volumes in legs, arms and neck were higher in athletes both in lying and standing positions. Before exercise the increase of heart rate and the decrease of a neck blood volume in response to tilting was lower (p athletes. The reactions in arms and abdomen blood volumes were similar. Also, the neck blood volumes as percentage of CSV (%/CSV) did not change in the control but increased in athletes (p athletes. The neck blood flow (%/CSV) did not change in athletes but decreased in control (pathletes both before and after exercise during fatigue which is due to effective distribution of blood flows aimed at maintaining cerebral blood flow.

  17. Simultaneous determination of extracellular volume and blood volume with the Volemetron

    NARCIS (Netherlands)

    Planque, B.A. de; Geyskes, C.G.; Dongen, R. van; Dorhout Mees, E.J.

    A new instrument, the “Volemetron”***, constructed to measure blood volume with radioactive isotopes, was adapted to determine 82Br distribution volume. Details of the technique arc given. Mean values of both RISA and 82Br distribution volume in normal men and women were determined. They were in

  18. Volume Flow in Arteriovenous Fistulas Using Vector Velocity Ultrasound

    DEFF Research Database (Denmark)

    Hansen, Peter Møller; Olesen, Jacob Bjerring; Pihl, Michael Johannes

    2014-01-01

    Volume flow in arteriovenous fistulas for hemodialysis was measured using the angle-independent ultrasound technique Vector Flow Imaging and compared with flow measurements using the ultrasound dilution technique during dialysis. Using an UltraView 800 ultrasound scanner (BK Medical, Herlev......, Denmark) with a linear transducer, 20 arteriovenous fistulas were scanned directly on the most superficial part of the fistula just before dialysis. Vector Flow Imaging volume flow was estimated with two different approaches, using the maximum and the average flow velocities detected in the fistula. Flow...

  19. Intraoperative cerebral blood flow imaging of rodents

    Science.gov (United States)

    Li, Hangdao; Li, Yao; Yuan, Lu; Wu, Caihong; Lu, Hongyang; Tong, Shanbao

    2014-09-01

    Intraoperative monitoring of cerebral blood flow (CBF) is of interest to neuroscience researchers, which offers the assessment of hemodynamic responses throughout the process of neurosurgery and provides an early biomarker for surgical guidance. However, intraoperative CBF imaging has been challenging due to animal's motion and position change during the surgery. In this paper, we presented a design of an operation bench integrated with laser speckle contrast imager which enables monitoring of the CBF intraoperatively. With a specially designed stereotaxic frame and imager, we were able to monitor the CBF changes in both hemispheres during the rodent surgery. The rotatable design of the operation plate and implementation of online image registration allow the technician to move the animal without disturbing the CBF imaging during surgery. The performance of the system was tested by middle cerebral artery occlusion model of rats.

  20. Cerebral blood flow in normal pressure hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Mamo, H.L.; Meric, P.C.; Ponsin, J.C.; Rey, A.C.; Luft, A.G.; Seylaz, J.A.

    1987-11-01

    A xenon-133 method was used to measure cerebral blood flow (CBF) before and after cerebrospinal fluid (CSF) removal in patients with normal pressure hydrocephalus (NPH). Preliminary results suggested that shunting should be performed on patients whose CBF increased after CSF removal. There was a significant increase in CBF in patients with NPH, which was confirmed by the favorable outcome of 88% of patients shunted. The majority of patients with senile and presenile dementia showed a decrease or no change in CBF after CSF removal. It is suggested that although changes in CBF and clinical symptoms of NPH may have the same cause, i.e., changes in the cerebral intraparenchymal pressure, there is no simple direct relation between these two events. The mechanism underlying the loss of autoregulation observed in NPH is also discussed.

  1. Cerebral blood flow and metabolism during sleep

    DEFF Research Database (Denmark)

    Madsen, Peter Lund; Vorstrup, S

    1991-01-01

    A review of the current literature regarding sleep-induced changes in cerebral blood flow (CBF) and cerebral metabolic rate (CMR) is presented. Early investigations have led to the notion that dreamless sleep was characterized by global values of CBF and CMR practically at the level of wakefulness......, while rapid eye movement (REM) sleep (dream sleep) was a state characterized by a dramatically increased level of CBF and possibly also of CMR. However, recent investigations firmly contradict this notion. Investigations on CBF and CMR performed during non-REM sleep, taking the effect of different...... levels of sleep into consideration, show that light sleep (stage II) is characterized by global levels of CBF and CMR only slightly reduced by 3-10% below the level associated with wakefulness, whereas CBF and CMR during deep sleep (stage III-IV) is dramatically reduced by 25-44%. Furthermore, recent...

  2. Blood flow and oxygenation in peritendinous tissue and calf muscle during dynamic exercise in humans

    DEFF Research Database (Denmark)

    Boushel, R; Langberg, Henning; Green, Stefan Mathias

    2000-01-01

    1. Circulation around tendons may act as a shunt for muscle during exercise. The perfusion and oxygenation of Achilles' peritendinous tissue was measured in parallel with that of calf muscle during exercise to determine (1) whether blood flow is restricted in peritendinous tissue during exercise...... with a rise in leg vascular conductance and microvascular haemoglobin volume, despite elevated systemic vascular resistance. 4. The parallel rise in calf muscle and peritendinous blood flow and fall in O2 saturation during exercise indicate that blood flow is coupled to oxidative metabolism in both tissue...... by dye dilution, arterial pressure by an arterial catheter-transducer, and muscle and peritendinous O2 saturation by spatially resolved spectroscopy (SRS). 3. Calf blood flow rose 20-fold with exercise, reaching 44 +/- 7 ml (100 g)-1 min-1 (mean +/- s.e.m. ) at 9 W, while Achilles' peritendinous flow...

  3. Remifentanil decreases oral tissue blood flow while maintaining internal carotid artery blood flow during sevoflurane anesthesia in rabbits.

    Science.gov (United States)

    Hirata, Atsushi; Kasahara, Masataka; Matsuura, Nobuyuki; Ichinohe, Tatsuya

    2017-12-22

    The aim of this study was to investigate the effect of remifentanil infusion on oral tissue blood flow including submandibular gland tissue blood flow (SBF) and internal carotid artery blood flow (ICBF) in rabbits during sevoflurane anesthesia. Twelve male Japan White rabbits were anesthetized with sevoflurane and remifentanil. Remifentanil was infused at 0.2 and 0.4 µg/kg/min. Measurements included circulatory variables, common and external carotid artery blood flow (CCBF, ECBF), ICBF, tongue mucosal blood flow (TMBF), masseter muscle tissue blood flow (MBF), mandibular bone marrow tissue blood flow (BBF), tongue muscle tissue blood flow (TBF), and SBF. Vascular resistances for each tissue, including the tongue mucosa, masseter muscle, mandibular bone marrow, tongue muscle, and submandibular gland, were calculated by dividing the mean arterial pressure by the respective tissue blood flow. Remifentanil infusion decreased oral tissue blood flow and circulatory variables. CCBF, ECBF, and ICBF did not change. The calculated vascular resistance in each oral tissue, except for the tongue mucosa, increased in an infusion-rate-dependent manner. These results showed that remifentanil infusion reduced TMBF, MBF, BBF, TBF, and SBF in an infusion-rate-dependent manner without affecting ICBF under sevoflurane anesthesia.

  4. Effect of glomerulopressin on ovarian blood flow in dogs.

    Science.gov (United States)

    Uranga, J; Del Castillo, E

    1979-10-01

    The present study showed that glomerulopressin decreased ovarian blood flow in normal dogs and that this effect could be inhibited by treatment with indomethacin. In addition diabetic dogs had a high plasma level of glomerulopressin and a low ovarian blood flow that was shown to increase after treatment with indomethacin. This suggests that the low ovarian blood flow in diabetis might be due to a prostaglandin synthesizing effect of glomerulopressin.

  5. Effects of relative blood volume-controlled hemodialysis on blood pressure and volume status in hypertensive patients

    NARCIS (Netherlands)

    Dasselaar, J.J.; Huisman, R.M.; De Jong, P.E.; Burgerhof, J.G.M.; Franssen, C.F.M.

    2007-01-01

    In hypertensive hemodialysis (HD) patients, dry weight reduction to normalize blood pressure (BP) often results in increased frequency of HD hypotension. Because HD with blood volume tracking (BVT) has been shown to improve intra-HD hemodynamic stability, we performed a prospective, randomized study

  6. Forearm blood flow responses of offspring of hypertensives to an extended stress task.

    Science.gov (United States)

    Ditto, B; Miller, S B

    1989-02-01

    The forearm blood flow and other cardiovascular responses of 10 healthy young men with a parental history of hypertension to an extended laboratory stressor were compared with the responses of 10 age-matched men with normotensive parents. To eliminate the effects of the anticipation of stress on baseline measures, all subjects participated in a separate 1-hour counterbalanced baseline session in which no stress was presented. There were no significant differences between the two groups in resting blood pressure, heart rate, blood volume pulse, forearm blood flow and vascular resistance, and self-report anxiety, although offspring of hypertensive parents exhibited marginally greater (p = 0.08) forearm blood flow at rest. During the stress session, subjects played video games for 1 hour and avoided mild electric shocks depending on performance. Offspring of hypertensive parents exhibited significantly greater heart rate (+19 +/- 6 vs. +3 +/- 2%), forearm blood flow (+52 +/- 14 vs. +9 +/- 4%), and self-report anxiety (+25 +/- 6 vs. +9 +/- 3%) responses to the task. There were no significant group differences in blood pressure response to the task. Significant positive correlations between forearm blood flow and heart rate responses to the task were observed. These findings extend earlier results that suggested healthy young offspring of hypertensive and normotensive parents may exhibit different patterns of hemodynamic response to stress in the absence of differences in resting blood pressure or blood pressure responsiveness to stress.

  7. Dynamic Effect of Rolling Massage on Blood Flow

    Science.gov (United States)

    Chen, Yan-Yan; Yi, Hou-Hui; Li, Hua-Bing; Fang, Hai-Ping

    2009-02-01

    The Chinese traditional medical massage has been used as a natural therapy to eliminate some diseases. Here, the effect of the rolling massage frequency to the blood flow in the blood vessels under the rolling massage manipulation is studied by the lattice Boltzmann simulation. The simulation results show that when the frequency is smaller than or comparable to the pulsatile frequency of the blood flow, the effect on the blood flux by the rolling massage is small. On the contrast, if the frequency is twice or more times of the pulsatile frequency of the blood flow, the blood flux is greatly enhanced and increases linearly with respect to the frequency. Similar behavior has also been observed on the shear stress on the blood vessel walls. The result is helpful for understanding that the rolling massage has the function of promoting the blood circulation and removing the blood stasis.

  8. Renal sympathetic nerve, blood flow, and epithelial transport responses to thermal stress.

    Science.gov (United States)

    Wilson, Thad E

    2017-05-01

    Thermal stress is a profound sympathetic stress in humans; kidney responses involve altered renal sympathetic nerve activity (RSNA), renal blood flow, and renal epithelial transport. During mild cold stress, RSNA spectral power but not total activity is altered, renal blood flow is maintained or decreased, and epithelial transport is altered consistent with a sympathetic stress coupled with central volume loaded state. Hypothermia decreases RSNA, renal blood flow, and epithelial transport. During mild heat stress, RSNA is increased, renal blood flow is decreased, and epithelial transport is increased consistent with a sympathetic stress coupled with a central volume unloaded state. Hyperthermia extends these directional changes, until heat illness results. Because kidney responses are very difficult to study in humans in vivo, this review describes and qualitatively evaluates an in vivo human skin model of sympathetically regulated epithelial tissue compared to that of the nephron. This model utilizes skin responses to thermal stress, involving 1) increased skin sympathetic nerve activity (SSNA), decreased skin blood flow, and suppressed eccrine epithelial transport during cold stress; and 2) increased SSNA, skin blood flow, and eccrine epithelial transport during heat stress. This model appears to mimic aspects of the renal responses. Investigations of skin responses, which parallel certain renal responses, may aid understanding of epithelial-sympathetic nervous system interactions during cold and heat stress. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Regional blood volume in man determined by radiolabelled erythrocytes

    Energy Technology Data Exchange (ETDEWEB)

    Vissing, S.F.; Nielsen, S.L.

    1988-06-01

    The purpose of the present study was to develop a non-invasive method capable of measuring the regional blood volume in the peripheral circulation. External counting of autologous radiolabelled erythrocytes was performed by dynamic scintigraphy of the calf. During short venous stasis, synchronous changes in segmental blood volumes were recorded by plethysmography, thereby obtaining a calibration factor. The recordings were performed with the position of the calf varying between elevated, horizontal and lowered before and after 4.5 min venous stasis with a tourniquet pressure of 57 mmHg applied above the knee. The mean blood volume comprised 3.2 (1.2) ml per 100 ml tissue in the elevated position, 6.0 (1.6) in the horizontal position and 9.8 (2.6) in the lowered position. Correspondingly, the blood volume increase during venous stasis was 120%, 60% and 20% in the three positions. Studies of the reproducibility showed a coefficient of variation of 13.5%. The present study suggests that the method of blood volume measuring should be further evaluated to study the function of capacitance vessels.

  10. Daily rhythm of cerebral blood flow velocity

    Directory of Open Access Journals (Sweden)

    Spielman Arthur J

    2005-03-01

    Full Text Available Abstract Background CBFV (cerebral blood flow velocity is lower in the morning than in the afternoon and evening. Two hypotheses have been proposed to explain the time of day changes in CBFV: 1 CBFV changes are due to sleep-associated processes or 2 time of day changes in CBFV are due to an endogenous circadian rhythm independent of sleep. The aim of this study was to examine CBFV over 30 hours of sustained wakefulness to determine whether CBFV exhibits fluctuations associated with time of day. Methods Eleven subjects underwent a modified constant routine protocol. CBFV from the middle cerebral artery was monitored by chronic recording of Transcranial Doppler (TCD ultrasonography. Other variables included core body temperature (CBT, end-tidal carbon dioxide (EtCO2, blood pressure, and heart rate. Salivary dim light melatonin onset (DLMO served as a measure of endogenous circadian phase position. Results A non-linear multiple regression, cosine fit analysis revealed that both the CBT and CBFV rhythm fit a 24 hour rhythm (R2 = 0.62 and R2 = 0.68, respectively. Circadian phase position of CBT occurred at 6:05 am while CBFV occurred at 12:02 pm, revealing a six hour, or 90 degree difference between these two rhythms (t = 4.9, df = 10, p Conclusion In conclusion, time of day variations in CBFV have an approximately 24 hour rhythm under constant conditions, suggesting regulation by a circadian oscillator. The 90 degree-phase angle difference between the CBT and CBFV rhythms may help explain previous findings of lower CBFV values in the morning. The phase difference occurs at a time period during which cognitive performance decrements have been observed and when both cardiovascular and cerebrovascular events occur more frequently. The mechanisms underlying this phase angle difference require further exploration.

  11. Colloid volume loading does not mitigate decreases in central blood volume during simulated hemorrhage while heat stressed

    DEFF Research Database (Denmark)

    Crandall, Craig G; Wilson, Thad E; Marving, Jens

    2012-01-01

    intravenous colloid volume loading (11 ml/kg). Relative changes in torso and regional blood volumes were determined by gamma camera imaging with technetium-99m labeled erythrocytes. Heat stress reduced blood volume in all regions (ranging from 7 to 16%), while subsequent volume loading returned those values......±5%, all P0.05 relative to heat stress alone). These data suggest that blood volume loading during passive heat stress (via 11 ml/kg of a colloid solution) normalizes regional blood volumes in the torso, but does not mitigate the reduction in central blood volume during a simulated hemorrhagic challenge...

  12. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  13. EFFECT OF INCREASED WHOLE-BLOOD VISCOSITY ON REGIONAL BLOOD FLOWS IN CHRONICALLY HYPOXEMIC LAMBS

    NARCIS (Netherlands)

    DALINGHAUS, M; KNOESTER, H; GRATAMA, JWC; VANDERMEER, J; ZIJLSTRA, WG; KUIPERS, JRG

    In chronic hypoxemia blood flow and oxygen supply to vital organs are maintained, but to nonvital organs they are decreased. We measured organ blood flows (microspheres) and whole blood viscosity in 10 chronically hypoxemic lambs, with an atrial septal defect and pulmonary stenosis, and in 8 control

  14. Changes in scalp and cortical blood flow during hyperventilation measured with diffusing-wave spectroscopy

    Science.gov (United States)

    Li, Jun; Ninck, Markus; Gisler, Thomas

    2009-07-01

    Changes in scalp and cortical blood flow induced by voluntary hyperventilation are investigated by near-infrared diffusing-wave spectroscopy. The temporal intensity autocorrelation function g(2) (τ) of multiply scattered light is recorded from the forehead of subjects during hyperventilation. Blood flow within the sampled tissue volume is estimated by the mean decay rate of g(2) (τ) . Data measured from six subjects show that the pattern of the hemodynamic response during 50 s hyperventilation is rather complicated: within the first 10 s, in three subjects an initial increase in blood flow is observed; from 10 s to 20 s, the mean blood flow is smaller than its baseline value for all six subjects; for the duration from 20 s to 30 s, the blood flow increases again. However, after 30 s the change is not consistent across subjects. Further study on one of these subjects by using two receivers probing the blood flow in the cortex and in the superficial layers simultaneously, reveals that during hyperventilation, the direction of change in blood flow within the scalp is opposite to the one in the brain. This helps to understand the complicated hemodynamic response observed in our measurements.

  15. Biology and Mechanics of Blood Flows Part I: Biology

    CERN Document Server

    Thiriet, Marc

    2008-01-01

    Biology and Mechanics of Blood Flows presents the basic knowledge and state-of-the-art techniques necessary to carry out investigations of the cardiovascular system using modeling and simulation. Part I of this two-volume sequence, Biology, addresses the nanoscopic and microscopic scales. The nanoscale corresponds to the scale of biochemical reaction cascades involved in cell adaptation to mechanical stresses among other stimuli. The microscale is the scale of stress-induced tissue remodeling associated with acute or chronic loadings. The cardiovascular system, like any physiological system, has a complicated three-dimensional structure and composition. Its time dependent behavior is regulated, and this complex system has many components. In this authoritative work, the author provides a survey of relevant cell components and processes, with detailed coverage of the electrical and mechanical behaviors of vascular cells, tissues, and organs. Because the behaviors of vascular cells and tissues are tightly coupl...

  16. Aerobic fitness is associated with greater hippocampal cerebral blood flow in children

    Directory of Open Access Journals (Sweden)

    Laura Chaddock-Heyman

    2016-08-01

    Full Text Available The present study is the first to investigate whether cerebral blood flow in the hippocampus relates to aerobic fitness in children. In particular, we used arterial spin labeling (ASL perfusion MRI to provide a quantitative measure of blood flow in the hippocampus in 73 7- to 9-year-old preadolescent children. Indeed, aerobic fitness was found to relate to greater perfusion in the hippocampus, independent of age, sex, and hippocampal volume. Such results suggest improved microcirculation and cerebral vasculature in preadolescent children with higher levels of aerobic fitness. Further, aerobic fitness may influence how the brain regulates its metabolic demands via blood flow in a region of the brain important for learning and memory. To add specificity to the relationship of fitness to the hippocampus, we demonstrate no significant association between aerobic fitness and cerebral blood flow in the brainstem. Our results reinforce the importance of aerobic fitness during a critical period of child development.

  17. LEGS AND TRUNK MUSCLE HYPERTROPHY FOLLOWING WALK TRAINING WITH RESTRICTED LEG MUSCLE BLOOD FLOW

    Directory of Open Access Journals (Sweden)

    Mikako Sakamaki

    2011-06-01

    Full Text Available We examined the effect of walk training combined with blood flow restriction (BFR on the size of blood flow-restricted distal muscles, as well as, on the size of non-restricted muscles in the proximal limb and trunk. Nine men performed walk training with BFR and 8 men performed walk training alone. Training was conducted two times a day, 6 days/wk, for 3 wk using five sets of 2-min bouts (treadmill speed at 50 m/min, with a 1-min rest between bouts. After walk training with BFR, MRI-measured upper (3.8%, P < 0.05 and lower leg (3.2%, P < 0. 05 muscle volume increased significantly, whereas the muscle volume of the gluteus maximus (-0.6% and iliopsoas (1.8% and the muscle CSA of the lumber L4-L5 (-1.0 did not change. There was no significant change in muscle volume in the walk training alone. Our results suggest that the combination of leg muscle blood flow restriction with slow walk training elicits hypertrophy only in the distal blood flow restricted leg muscles. Exercise intensity may be too low during BFR walk training to increase muscle mass in the non- blood flow restricted muscles (gluteus maximus and other trunk muscles.

  18. Subcutaneous blood flow during insulin-induced hypoglycaemia

    DEFF Research Database (Denmark)

    Hilsted, J; Madsbad, S; Sestoft, L

    1982-01-01

    Subcutaneous blood flow was measured preceding insulin-induced hypoglycaemia, at the onset of hypoglycaemic symptoms and 2 h later in juvenile diabetics with and without autonomic neuropathy and in normal males. In all groups subcutaneous blood flow decreased at the onset of hypoglycaemic symptoms...... compared with pre-hypoglycaemic flow. Two hours after onset of hypoglycaemic symptoms, subcutaneous blood flow was still significantly decreased compared with pre-hypoglycaemic flow. In normal subjects local nerve blockade had no effect on blood flow changes during hypoglycaemia, whereas local alpha......-receptor blockade abolished the vasoconstrictor response. We suggest that circulating catecholamines stimulating vascular alpha-receptors are probably responsible for flow reduction in the subcutaneous tissue during hypoglycaemia....

  19. Blood flow restricted exercise and vascular function.

    Science.gov (United States)

    Horiuchi, Masahiro; Okita, Koichi

    2012-01-01

    It is established that regular aerobic training improves vascular function, for example, endothelium-dependent vasodilatation and arterial stiffness or compliance and thereby constitutes a preventative measure against cardiovascular disease. In contrast, high-intensity resistance training impairs vascular function, while the influence of moderate-intensity resistance training on vascular function is still controversial. However, aerobic training is insufficient to inhibit loss in muscular strength with advancing age; thus, resistance training is recommended to prevent sarcopenia. Recently, several lines of study have provided compelling data showing that exercise and training with blood flow restriction (BFR) leads to muscle hypertrophy and strength increase. As such, BFR training might be a novel means of overcoming the contradiction between aerobic and high-intensity resistance training. Although it is not enough evidence to obtain consensus about impact of BFR training on vascular function, available evidences suggested that BFR training did not change coagulation factors and arterial compliance though with inconsistence results in endothelial function. This paper is a review of the literature on the impact of BFR exercise and training on vascular function, such as endothelial function, arterial compliance, or other potential factors in comparison with those of aerobic and resistance training.

  20. Suboccipital dermatomyotomic stimulation and digital blood flow.

    Science.gov (United States)

    Purdy, W R; Frank, J J; Oliver, B

    1996-05-01

    The effect of gentle, soft tissue manipulation in the suboccipital region on digital blood flow, as a measure of sympathetic nervous system activity, was studied. Digital strain gauge plethysmography was used to measure the changes in pulse contour during (1) a normative test period with the subject in the supine position, (2) after a control interval (placebo) during which the investigator placed his hands under the suboccipital region, and (3) after an interval during which the investigator's fingers applied slow, steady, circular kneading in the suboccipital triangle region. Twenty-five studies were performed in a crossover design with the patient as his or her own control. Total pulse amplitude (Y) and the height from the dicrotic notch to the peak (X) were measured. Examination of the total data of all subjects revealed the occurrence of a significant change in X and Y with simply touching the suboccipital region with the hands. An even more favorable response ensued when suboccipital manipulation was applied. Those subjects reporting comfort or neutral responses had larger significant changes with manipulation when compared with the group reporting the experience as uncomfortable. The response within each group suggests that favorable autonomic changes (sympathetic dampening) occur with specific suboccipital manipulation as well as, indeed, the simple touching of the suboccipital triangle.

  1. Blood Flow Restricted Exercise and Vascular Function

    Directory of Open Access Journals (Sweden)

    Masahiro Horiuchi

    2012-01-01

    Full Text Available It is established that regular aerobic training improves vascular function, for example, endothelium-dependent vasodilatation and arterial stiffness or compliance and thereby constitutes a preventative measure against cardiovascular disease. In contrast, high-intensity resistance training impairs vascular function, while the influence of moderate-intensity resistance training on vascular function is still controversial. However, aerobic training is insufficient to inhibit loss in muscular strength with advancing age; thus, resistance training is recommended to prevent sarcopenia. Recently, several lines of study have provided compelling data showing that exercise and training with blood flow restriction (BFR leads to muscle hypertrophy and strength increase. As such, BFR training might be a novel means of overcoming the contradiction between aerobic and high-intensity resistance training. Although it is not enough evidence to obtain consensus about impact of BFR training on vascular function, available evidences suggested that BFR training did not change coagulation factors and arterial compliance though with inconsistence results in endothelial function. This paper is a review of the literature on the impact of BFR exercise and training on vascular function, such as endothelial function, arterial compliance, or other potential factors in comparison with those of aerobic and resistance training.

  2. Effects of non-newtonian properties of blood flow on magnetic nanoparticle targeted drug delivery

    Directory of Open Access Journals (Sweden)

    Mobin Haghdel

    2017-04-01

    Full Text Available Objective(s: One applications of nanotechnology is in the area of medicine which is called nanomedicine. Primary instruments in nanomedicine can help us to detect diseases and used for drug delivery to inaccessible areas of human tissues. An important issue in simulating the motion of nanoparticles is modeling blood flow as a Newtonian or non-Newtonian fluid. Sometimes blood flow is simulated as a Newtonian fluid but actually blood has nature of non-Newtonian fluid.  Simulation of targeted drug delivery and motion of nanoparticles in the blood flow as Newtonian and non-Newtonian fluid flow is investigated in this paperMaterials and Methods: In this paper, the blood flow is modeled as both Newtonian and non-Newtonian fluid and the effects of each case on the motion of nanoparticles in blood flow and targeted drug delivery is investigated. The flow is modeled with finite volume method. The particle modeled with discrete phase model.Results: Cross, Herschel-Bulkley and Power-law models are used for simulating the non-Newtonian blood flow. Numerical simulations show that trajectory of nanoparticle’s movement and the required time to pass the vessel by blood flow is variable for different models. According to obtained results, non-Newtonian Power-law and Herschel-Bulkley models have closely similar results but they have significant differences compared with Newtonian model. Conclusion: According to the results, it is preferred in the simulation to model blood flow as a non-Newtonian fluid and uses one of Herschel- Bulkley or Power-law models. Otherwise the simulation is far different from real phenomena.

  3. Venous saturation and blood flow behavior during laser-induced photodissociation of oxyhemoglobin

    Science.gov (United States)

    Mamilov, S. A.; Yesman, S. S.; Asimov, M. M.; Gisbrecht, A. I.

    2013-03-01

    The value of relative oxyhemoglobin concentration (saturation) in arterial (SаO2) and venous blood (SvO2) plays a significant role in the oxygen exchange in tissue and is used as criterion of delivery of oxygen adequate to the needs of tissue cells. Reduction of the volume of blood flows as well as reduction of oxygen concentration in arterial blood causes hypoxia - deficit of oxygen in tissue. One of the main mechanisms of elimination of hypoxia is based on compensation of the oxygen deficit by increasing the oxygen extraction from arterial blood, which leads to reduction of oxygen in the venous blood 1. In this report two optical techniques for measurement of venous blood saturation are presented. The first one is based on the pulseoximetry with artificial mechanical modulation of the tissue volume and the second one on the spectrophotometry of human respiratory rhythm. Good correlation between the results obtained with both techniques is observed.

  4. A liquid-independent volume flow measurement principle

    NARCIS (Netherlands)

    Geers, L.F.G.; Volker, A.W.F.; Hunter, T.P.M.

    2010-01-01

    A novel flow measurement principle is presented enabling non-intrusive volume flow measurements of liquids in the ml/min range. It is based on an opto-acoustical time-of-flight principle, where the time interval is recorded in which a thermal label travels a known distance through a flow channel.

  5. Regional cerebral blood flow in focal cortical epilepsy

    DEFF Research Database (Denmark)

    Hougaard, Kristina Dupont; Oikawa, T; Sveinsdottir, E

    1976-01-01

    Regional cerebral blood flow (rCBF) was studied in ten patients with focal cortical epilepsy. The blood flow was measured by the intra-arterial injection of xenon 133 (133Xe), and the isotope clearance was recorded by a multidetector scintillation camera with 254 detectors. Three patients were st...

  6. Cholinesterase inhibition improves blood flow in the ischemic cerebral cortex.

    Science.gov (United States)

    Scremin, O U; Li, M G; Scremin, A M; Jenden, D J

    1997-01-01

    The ability of central cholinesterase inhibition to improve cerebral blood flow in the ischemic brain was tested in Sprague-Dawley rats with tandem occlusion of left middle cerebral and common carotid arteries. Cerebral blood flow was measured with lodo- 14C-antipyrine autoradiography in 170 regions of cerebral cortex. The regional distribution of blood flow was characterized in normal animals by cerebral blood flow maxima in the temporal regions. After 2 h ischemia, minimum cerebral blood flow values were found in the lateral frontal and parietal areas on the left hemisphere, and a new maximum was found in the right hemisphere in an area approximately symmetrical to the ischemic focus. Heptyl-physostigmine (eptastigmine), a carbamate cholinesterase inhibitor with prolonged time of action improved cerebral blood flow in most regions, with the exception of the ischemic core. The drug also enhanced the ischemia-induced rostral shift of cerebral blood flow maxima in the right hemisphere. The effects of eptastigmine were more marked 24 h after ischemia. Discriminant analysis showed that data from only 22 regions was sufficient to achieve 100% accuracy in classifying all cases into the various experimental conditions. The redistribution of cerebral blood flow to the sensorimotor area of the right hemisphere of animals with cerebral ischemia, a phenomenon possibly related to recovery of function, was also enhanced by eptastigmine.

  7. Multiphase simulation of blood flow within main thoracic arteries of 8-year-old child with coarctation of the aorta

    Science.gov (United States)

    Melka, Bartlomiej; Gracka, Maria; Adamczyk, Wojciech; Rojczyk, Marek; Golda, Adam; Nowak, Andrzej J.; Białecki, Ryszard A.; Ostrowski, Ziemowit

    2017-08-01

    In the research, a numerical Computational Fluid Dynamics (CFD) model of the pulsatile blood flow was created and analysed. A real geometry of aorta and its thoracic branches of an 8-year old patient diagnosed with a congenital heart defect - coarctation of the aorta was used. The inlet boundary condition was implemented as the User Define Function according to measured values of volumetric blood flow. The blood flow was treated as multiphase using Euler-Euler approach. Plasma was set as the primary and dominant fluid phase, with the volume fraction of 0.585. The morphological elements (RBC and WBC) were set as dispersed phases being the remaining volume fraction.

  8. Childhood Kidney Outcomes in Relation to Fetal Blood Flow and Kidney Size

    Science.gov (United States)

    Kooijman, Marjolein N.; Bakker, Hanneke; van der Heijden, Albert J.; Hofman, Albert; Franco, Oscar H.; Steegers, Eric A.P.; Taal, H. Rob

    2014-01-01

    Impaired fetal abdominal blood flow may lead to smaller kidneys and subsequent impaired kidney function in later life. In a prospective cohort study among 923 pregnant women and their children, we measured fetal growth, kidney volumes, and umbilical and cerebral artery blood flow (median gestational age of 30.3 weeks; 95% range, 28.5–32.7 weeks). We used a higher umbilical/cerebral artery pulsatility index ratio as an indicator of preferential fetal blood flow to the upper body parts at the expense of the intra-abdominal organs. At a median age of 5.9 years (95% range, 5.7–6.6 years), we measured childhood kidney volumes, creatinine and cystatin C blood levels, microalbuminuria, BP, and eGFR. A preferential fetal blood flow to the upper body parts at the expense of the intra-abdominal organs associated only with a smaller combined kidney volume in childhood. Fetal combined kidney volume positively associated with childhood combined kidney volume and eGFR, and inversely associated with childhood creatinine and cystatin C levels (all P values kidney volume had the lowest eGFR (difference, −6.36 ml/min per 1.73 m2; 95% confidence interval, −11.78 to −0.94 compared with children within the middle tertiles). These data suggest that impaired fetal blood to the abdominal organs and smaller fetal kidney size are associated with subclinical changes in kidney outcomes in school-aged children. PMID:24812167

  9. Childhood kidney outcomes in relation to fetal blood flow and kidney size.

    Science.gov (United States)

    Kooijman, Marjolein N; Bakker, Hanneke; van der Heijden, Albert J; Hofman, Albert; Franco, Oscar H; Steegers, Eric A P; Taal, H Rob; Jaddoe, Vincent W V

    2014-11-01

    Impaired fetal abdominal blood flow may lead to smaller kidneys and subsequent impaired kidney function in later life. In a prospective cohort study among 923 pregnant women and their children, we measured fetal growth, kidney volumes, and umbilical and cerebral artery blood flow (median gestational age of 30.3 weeks; 95% range, 28.5-32.7 weeks). We used a higher umbilical/cerebral artery pulsatility index ratio as an indicator of preferential fetal blood flow to the upper body parts at the expense of the intra-abdominal organs. At a median age of 5.9 years (95% range, 5.7-6.6 years), we measured childhood kidney volumes, creatinine and cystatin C blood levels, microalbuminuria, BP, and eGFR. A preferential fetal blood flow to the upper body parts at the expense of the intra-abdominal organs associated only with a smaller combined kidney volume in childhood. Fetal combined kidney volume positively associated with childhood combined kidney volume and eGFR, and inversely associated with childhood creatinine and cystatin C levels (all P values ratio and the lowest tertile of fetal combined kidney volume had the lowest eGFR (difference, -6.36 ml/min per 1.73 m(2); 95% confidence interval, -11.78 to -0.94 compared with children within the middle tertiles). These data suggest that impaired fetal blood to the abdominal organs and smaller fetal kidney size are associated with subclinical changes in kidney outcomes in school-aged children. Copyright © 2014 by the American Society of Nephrology.

  10. Multi-modal in vivo imaging of brain blood oxygenation, blood flow and neural calcium dynamics during acute seizures

    Science.gov (United States)

    Ringuette, Dene; Jeffrey, Melanie A.; Carlen, Peter L.; Levi, Ofer

    2016-03-01

    Dysfunction of the vascular endothelium has been implicated in the development of epilepsy. To better understand the relation between vascular function and seizure and provide a foundation for interpreting results from functional imaging in chronic disease models, we investigate the relationship between intracellular calcium dynamics and local cerebral blood flow and blood oxygen saturation during acute seizure-like events and pharmacological seizure rescue. To probe the relation between the aforementioned physiological markers in an acute model of epilepsy in rats, we integrated three different optical modalities together with electrophysiological recordings: Laser speckle contrast imaging (LSCI) was used to study changes in flow speeds, Intrinsic optical signal imaging (IOSI) was used to monitor changes in oxygenated, de-oxygenated, and total hemoglobin concentration, and Calcium-sensitive dye imaging was used to monitor intracellular calcium dynamics. We designed a dedicated cortical flow chamber to remove superficial blood and dye resulting from the injection procedure, which reduced spurious artifacts. The near infrared light used for IOSI and LSCI was delivered via a light pipe integrated with the flow chamber to minimize the effect of fluid surface movement on illumination stability. Calcium-sensitive dye was injected via a glass electrode used for recording the local field potential. Our system allowed us to observe and correlate increases in intracellular calcium, blood flow and blood volume during seizure-like events and provide a quantitative analysis of neurovascular coupling changes associated with seizure rescue via injection of an anti-convulsive agent.

  11. Self-separation of blood plasma from whole blood during the capillary flow in microchannel

    Science.gov (United States)

    Nunna, Bharath Babu; Zhuang, Shiqiang; Lee, Eon Soo

    2017-11-01

    Self-separation of blood plasma from whole blood in microchannels is of great importance due to the enormous range of applications in healthcare and diagnostics. Blood is a multiphase complex fluid, composed of cells suspended in blood plasma. RBCs are the suspended particles whose shape changes during the flow of blood. The primary constituents of blood are erythrocytes or red blood cells (RBCs), leukocytes or white blood cells (WBCs), thrombocytes or platelets and blood plasma. The existence of RBCs in blood makes the blood a non-Newtonian fluid. The current study of separation of blood plasma from whole blood during self-driven flows in a single microchannel without bifurcation, by enhancing the capillary effects. The change in the capillary effect results in a change in contact angle which directly influences the capillary flow. The flow velocity directly influences the net force acting on the RBCs and influence the separation process. The experiments are performed on the PDMS microchannels with different contact angles by altering the surface characteristics using plasma treatment. The change in the separation length is studied during the capillary flow of blood in microchannel. Bharath Babu Nunna is a researcher in mechanical engineering and implementing the novel and innovative technologies in the biomedical devices to enhance the sensitivity of the disease diagnosis.

  12. A lumped parameter model of cerebral blood flow control combining cerebral autoregulation and neurovascular coupling.

    Science.gov (United States)

    Spronck, Bart; Martens, Esther G H J; Gommer, Erik D; van de Vosse, Frans N

    2012-11-01

    Cerebral blood flow regulation is based on a variety of different mechanisms, of which the relative regulatory role remains largely unknown. The cerebral regulatory system expresses two regulatory properties: cerebral autoregulation and neurovascular coupling. Since partly the same mechanisms play a role in cerebral autoregulation and neurovascular coupling, this study aimed to develop a physiologically based mathematical model of cerebral blood flow regulation combining these properties. A lumped parameter model of the P2 segment of the posterior cerebral artery and its distal vessels was constructed. Blood flow regulation is exerted at the arteriolar level by vascular smooth muscle and implements myogenic, shear stress based, neurogenic, and metabolic mechanisms. In eight healthy subjects, cerebral autoregulation and neurovascular coupling were challenged by squat-stand maneuvers and visual stimulation using a checkerboard pattern, respectively. Cerebral blood flow velocity was measured using transcranial Doppler, whereas blood pressure was measured by finger volume clamping. In seven subjects, the model proposed fits autoregulation and neurovascular coupling measurement data well. Myogenic regulation is found to dominate the autoregulatory response. Neurogenic regulation, although only implemented as a first-order mechanism, describes neurovascular coupling responses to a great extent. It is concluded that our single, integrated model of cerebral blood flow control may be used to identify the main mechanisms affecting cerebral blood flow regulation in individual subjects.

  13. Altered cerebral blood flow and cerebrovascular function after voluntary exercise in adult mice.

    Science.gov (United States)

    Cahill, Lindsay S; Bishop, Jonathan; Gazdzinski, Lisa M; Dorr, Adrienne; Stefanovic, Bojana; Sled, John G

    2017-11-01

    The beneficial effects of physical exercise on brain health are well documented, yet how exercise modulates cerebrovascular function is not well understood. This study used continuous arterial spin labeling magnetic resonance imaging with a hypercapnic challenge to examine changes in cerebral blood flow and vascular function after voluntary exercise in healthy, adult mice. Thirty exercise mice and twenty-one control mice were imaged prior to the start of the exercise regime (at 12 weeks of age) and after 4 weeks of voluntary exercise. After the second in vivo imaging session, we performed high-resolution ex vivo anatomical brain imaging to correlate the structural brain changes with functional measures of flow and vascular reserve. We found that exercise resulted in increases in the normocapnic and hypercapnic blood flow in the hippocampus. Moreover, the change in normocapnic blood flow between pre-exercise and post-exercise was positively correlated to the hippocampal structure volume following exercise. There was no overall effect of voluntary exercise on blood flow in the motor cortex. Surprisingly, the hypercapnic hippocampal blood flow when measured prior to the start of exercise was predictive of subsequent exercise activity. Moreover, exercise was found to normalize this pre-existing difference in hypercapnic blood flow between mice.

  14. A reference frame for blood volume in children and adolescents

    Directory of Open Access Journals (Sweden)

    Donckerwolcke Raymond

    2006-02-01

    Full Text Available Abstract Background Our primary purpose was to determine the normal range and variability of blood volume (BV in healthy children, in order to provide reference values during childhood and adolescence. Our secondary aim was to correlate these vascular volumes to body size parameters and pubertal stages, in order to determine the best normalisation parameter. Methods Plasma volume (PV and red cell volume (RCV were measured and F-cell ratio was calculated in 77 children with idiopathic nephrotic syndrome in drug-free remission (mean age, 9.8 ± 4.6 y. BV was calculated as the sum of PV and RCV. Due to the dependence of these values on age, size and sex, all data were normalised for body size parameters. Results BV normalised for lean body mass (LBM did not differ significantly by sex (p Conclusion LBM was the anthropometric index most closely correlated to vascular fluid volumes, independent of age, gender and pubertal stage.

  15. Conditions of microvessel occlusion for blood coagulation in flow.

    Science.gov (United States)

    Bouchnita, A; Galochkina, T; Kurbatova, P; Nony, P; Volpert, V

    2017-09-01

    Vessel occlusion is a perturbation of blood flow inside a blood vessel because of the fibrin clot formation. As a result, blood circulation in the vessel can be slowed down or even stopped. This can provoke the risk of cardiovascular events. In order to explore this phenomenon, we used a previously developed mathematical model of blood clotting to describe the concentrations of blood factors with a reaction-diffusion system of equations. The Navier-Stokes equations were used to model blood flow, and we treated the clot as a porous medium. We identify the conditions of partial or complete occlusion in a small vessel depending on various physical and physiological parameters. In particular, we were interested in the conditions on blood flow and diameter of the wounded area. The existence of a critical flow velocity separating the regimes of partial and complete occlusion was demonstrated through the mathematical investigation of a simplified model of thrombin wave propagation in Poiseuille flow. We observed different regimes of vessel occlusion depending on the model parameters both for the numerical simulations and in the theoretical study. Then, we compared the rate of clot growth in flow obtained in the simulations with experimental data. Both of them showed the existence of different regimes of clot growth depending on the velocity of blood flow. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Quantitative measurement of the blood flow in peripheral vascular diseases by a new radionuclide plethysmography

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, K.; Mori, Y.; Mashima, Y.; Shimada, T.; Fukuoka, M.

    1985-05-01

    The purpose of the study is to introduce a new plethysmography using radionuclide (RN) for a quantitative measurement of the blood flow in the extremities following the routine RN angiography. Seventy five patients with various peripheral artery diseases have been examined. RN pletysmography was performed in the supine position 15 min. after the RN angiography using 15 mCi of Tc-99m RBC. The blood flow (F) was calculated by the equation (1) which consists of three parameters, the initial slope of the time-activity curve (dc/dt*t=0) after the venous occlusion on the thigh, changes of radio-activity (C-Co) before and after avascularization by inflation of cuff with 200 mmHg pressure at calf, and the blood volume per unit tissue volume (..beta..=Vb/V,ml/100g tissue). F (ml/min/100g) = ..beta.. (dc/dt*t=0)/C-Co. The blood flow measured simultaneously by RN plethysmography and admittance plethysmography was significantly correlated (r = 0.906,n = 16). The blood flow in 67 normal subjects was 2.78 +- 0.75 ml/min/100g. In the patients with intermittent claudication the blood flow was decreased (1.89 +- 0.75 ml/min/100g,n = 75). In the cases with poorly developed colateral circulation the blood flow markedly decreased (1.62 +- 0.29 ml/min/100g,n = 10). Increases of blood flow after exercise was small in the cases with stenosis, even in patients with collaterals. This method is very useful to evaluate quantitatively the peripheral hemodynamics following the routine RN angiographic examination.

  17. Effect of pulsatile swirling flow on stenosed arterial blood flow.

    Science.gov (United States)

    Ha, Hojin; Lee, Sang Joon

    2014-09-01

    The existence of swirling flow phenomena is frequently observed in arterial vessels, but information on the fluid-dynamic roles of swirling flow is still lacking. In this study, the effects of pulsatile swirling inlet flows with various swirling intensities on the flow field in a stenosis model are experimentally investigated using a particle image velocimetry velocity field measurement technique. A pulsatile pump provides cyclic pulsating inlet flow and spiral inserts with two different helical pitches (10D and 10/3D) induce swirling flow in the stenosed channel. Results show that the pulsatile swirling flow has various beneficial effects by reducing the negative wall shear stress, the oscillatory shear index, and the flow reverse coefficient at the post-stenosis channel. Temporal variations of vorticity fields show that the short propagation length of the jet flow and the early breakout of turbulent flow are initiated as the swirling flow disturbs the symmetric development of the shear layer. In addition, the overall energy dissipation rate of the flow is suppressed by the swirling component of the flow. The results will be helpful for elucidating the hemodynamic characteristics of atherosclerosis and discovering better diagnostic procedures and clinical treatments. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. On the flow dependency of the electrical conductivity of blood

    NARCIS (Netherlands)

    Hoetink, AE; Faes, TJC; Visser, KR; Heethaar, RM

    Experiments presented in the literature show that the electrical conductivity of flowing blood depends on flow velocity. The aim of this study is to extend the Maxwell-Fricke theory, developed for a dilute suspension of ellipsoidal particles in an electrolyte, to explain this flow dependency of the

  19. Portable Low-Volume Therapy for Severe Blood Loss

    Science.gov (United States)

    2015-06-01

    greatly reduced blood flow resulting from heart beat reduction to 3-10 bpm when animals are in torpor. These hypothermic torpor bouts are regularly...interrupted with brief periods of normothermia (37°C) and normal heart rates of 300-400 bpm (5). This dramatic change in animal physiology resembles...prolonged survival up to ten days post-blood return compared to control solutions (13). The same solution has been tested in a porcine model of

  20. [Development of ultrasound-based monitor of relative blood volume].

    Science.gov (United States)

    Jiang, Shunzhong; Hu, Xiao; Liang, Zhongwei; Fan, Jianghong; Xia, Wubing; Zhou, Hongbo; Yi, Wei

    2013-12-01

    Assessing dry weight accurately is crucial in providing effective and safe haemodialysis. Biases towards dry weight assessment may bring a series of dialysis complications. This study introduces an online detection technique of relative blood volume (RBV) based on ultrasound, which analyzes the correlation between changes in blood density and sound speed. By measuring the attenuation in sound velocity, this method was employed to calculate RBV, and then to evaluate the dry weight of patients on dialysis. TDC-GP2 time measurement chip and MSP430 Single-chip Microcontroller (SCM) were used in the system to measure the ultrasonic travel time. In the clinical trials, RBV values range between 71.3% and 108.1%, showing consistent result with Fresenius 4008S blood volume monitor (BVM). This detection method possesses several advantages, such as real time, convenient, reproducible, non-invasive, and etc.

  1. A microcomputer system for assessment of peripheral blood flow. An example of nasal blood flow.

    Science.gov (United States)

    Grönfors, T; Pyykkö, I; Aalto, H; Juhola, M; Ishizaki, H

    1991-01-01

    We have designed and implemented a microcomputer system for studying the effect of various mediator substances on the nasal blood flow. The system uses an IBM PC/AT microcomputer, which is connected with a Laser Doppler Flowmeter (LDF) and an iontophoretic drug application system. The LDF measures flux from the tissue that in the example is the inferior nasal turbinate. The flux is converted to digital form by an analog-digital converter of 12 bits. The program is implemented in the Pascal language. In the analysis, a flux level, amplitude, rise time and decay time of the pulse wave are determined. The effect of drugs on the flux can be studied by applying them iontophoretically. In the program the length and number of the drug application periods as well as the recording period are user-driven. In the nasal blood flow iontophoretically administered adrenaline reduced significantly the flux parameters and histamine canceled this effect. Tachyphylalaxis was a frequent observation in repeated measurements. The system can be used to evaluate the role of different transmitters in the etiology of chronic rhinitis.

  2. Evaluation of Placental Blood Flow in Patients with Placental Insufficiency

    Directory of Open Access Journals (Sweden)

    Julia E. Dobrokhotova

    2017-03-01

    Full Text Available Background: Placental insufficiency is a major problem of modern obstetrics due to its link to maternal and perinatal morbidity and mortality. Placental microcirculatory disorders play a decisive role in the pathogenesis of this condition. Thus, an evaluation of placental blood flow is of particular importance and crucial for appropriate diagnosis. The aim of this study was to evaluate placental blood flow in patients with placental insufficiency. SMI (superb microvascular imaging was compared to color Doppler for that purpose. Materials and Methods: Primigravida patients (n=91 at 15 to 16 weeks of gestation were enrolled. Inclusion criteria were spontaneous singleton pregnancy, age from 18 to 45 years. All participants were divided into 2 groups: Group 1 – control group (n=27 and Group 2 – threatened miscarriage group (n=64. Transvaginal ultrasound and color Doppler were performed to assess uteroplacental circulation. Placental blood flow was evaluated using a Toshiba Aplio™ 500 machine equipped with an SMI tool. Results: Placental blood flow assessment in patients with normal pregnancy revealed homogenous placental tissue, normal distribution of vessels, and active blood flow; in patients with pregnancy complications, we found inhomogeneous placenta, decreased blood flow, sporadic vessels, and avascular areas. SMI demonstrated several benefits compared to color Doppler imaging. Color Doppler allows us to assess superficial vessels only, whereas SMI provides more comprehensive data on the overall vascularization of the placenta. Conclusion: SMI by Aplio™ 500 (Toshiba may be an effective tool in the assessment of placental blood flow and the diagnosis and prognosis of placental insufficiency.

  3. Mesenteric, coeliac and splanchnic blood flow in humans during exercise

    DEFF Research Database (Denmark)

    Perko, M J; Nielsen, H B; Skak, C

    1998-01-01

    1. Exercise reduces splanchnic blood flow, but the mesenteric contribution to this response is uncertain. 2. In nineteen humans, superior mesenteric and coeliac artery flows were determined by duplex ultrasonography during fasting and postprandial submaximal cycling and compared with the splanchnic...... blood flow as assessed by the Indocyanine Green dye-elimination technique. 3. Cycling increased arterial pressure, heart rate and cardiac output, while it reduced total vascular resistance. These responses were not altered in the postprandial state. During fasting, cycling increased mesenteric, coeliac...... the coeliac circulation was not influenced. Postprandial cycling did not influence the mesenteric resistance significantly, but its blood flow decreased by 22 % (0.46 +/- 0.28 l min-1). Coeliac and splanchnic resistance increased by 150 and 63 %, respectively, and the corresponding regional blood flow...

  4. Mesenteric, coeliac and splanchnic blood flow in humans during exercise

    DEFF Research Database (Denmark)

    Perko, M J; Nielsen, H B; Skak, C

    1998-01-01

    1. Exercise reduces splanchnic blood flow, but the mesenteric contribution to this response is uncertain. 2. In nineteen humans, superior mesenteric and coeliac artery flows were determined by duplex ultrasonography during fasting and postprandial submaximal cycling and compared with the splanchnic...... blood flow as assessed by the Indocyanine Green dye-elimination technique. 3. Cycling increased arterial pressure, heart rate and cardiac output, while it reduced total vascular resistance. These responses were not altered in the postprandial state. During fasting, cycling increased mesenteric, coeliac...... decreased by 51 and 31 % (0.49 +/- 0.07 and 0.96 +/- 0.28 l min-1). Splanchnic blood flow values assessed by duplex ultrasound and by dye-elimination techniques were correlated (r = 0.70; P exercise in humans, splanchnic resistance increases and blood flow is reduced following...

  5. Determinants of coronary blood flow in sandbar sharks, Carcharhinus plumbeus.

    Science.gov (United States)

    Cox, Georgina K; Brill, Richard W; Bonaro, Kaitlin A; Farrell, Anthony P

    2017-02-01

    The coronary circulation first appeared in the chordate lineage in cartilaginous fishes where, as in birds and mammals but unlike most teleost fishes, it supplies arterial blood to the entire myocardium. Despite the pivotal position of elasmobranch fishes in the evolution of the coronary circulation, the determinants of coronary blood flow have never been investigated in this group. Elasmobranch fishes are of special interest because of the morphological arrangement of their cardiomyocytes. Unlike teleosts, the majority of the ventricular myocardium in elasmobranch fishes is distant to the venous blood returning to the heart (i.e., the luminal blood). Also, the majority of the myocardium is in close association with the coronary circulation. To determine the relative contribution of the coronary and luminal blood supplies to cardiovascular function in sandbar sharks, Carcharhinus plumbeus, we measured coronary blood flow while manipulating cardiovascular status using acetylcholine and adrenaline. By exploring inter- and intra-individual variation in cardiovascular variables, we show that coronary blood flow is directly related to heart rate (R 2 = 0.6; P coronary blood flow is inversely related to coronary resistance both in vivo and in vitro, we suggest that in elasmobranch fishes, changes in heart rate mediate changes in coronary vascular resistance, which adjust coronary blood flow appropriately.

  6. Connexin 36 mediates blood cell flow in mouse pancreatic islets.

    Science.gov (United States)

    Short, Kurt W; Head, W Steve; Piston, David W

    2014-02-01

    The insulin-secreting β-cells are contained within islets of Langerhans, which are highly vascularized. Blood cell flow rates through islets are glucose-dependent, even though there are no changes in blood cell flow within in the surrounding exocrine pancreas. This suggests a specific mechanism of glucose-regulated blood flow in the islet. Pancreatic islets respond to elevated glucose with synchronous pulses of electrical activity and insulin secretion across all β-cells in the islet. Connexin 36 (Cx36) gap junctions between islet β-cells mediate this synchronization, which is lost in Cx36 knockout mice (Cx36(-/-)). This leads to glucose intolerance in these mice, despite normal plasma insulin levels and insulin sensitivity. Thus, we sought to investigate whether the glucose-dependent changes in intraislet blood cell flow are also dependent on coordinated pulsatile electrical activity. We visualized and quantified blood cell flow using high-speed in vivo fluorescence imaging of labeled red blood cells and plasma. With the use of a live animal glucose clamp, blood cell flow was measured during either hypoglycemia (∼50 mg/dl) or hyperglycemia (∼300 mg/dl). In contrast to the large glucose-dependent islet blood velocity changes observed in wild-type mice, only minimal differences are observed in both Cx36(+/-) and Cx36(-/-) mice. This observation supports a novel model where intraislet blood cell flow is regulated by the coordinated electrical activity in the islet β-cells. Because Cx36 expression and function is reduced in type 2 diabetes, the resulting defect in intraislet blood cell flow regulation may also play a significant role in diabetic pathology.

  7. What is the blood flow to resting human muscle?

    Science.gov (United States)

    Elia, M; Kurpad, A

    1993-05-01

    1. An investigation was carried out in five healthy lean adults to assess whether forearm and calf plethysmography largely reflect muscle blood flow as measured by 133Xe and whether there is substantial variability in the blood flow to muscles located at different sites in the body. 2. Blood flow to forearm and calf flexors and extensors, biceps, triceps and quadriceps was assessed using the 133Xe clearance technique. Blood flow to forearm skin and subcutaneous adipose tissue was also measured using the 133Xe clearance technique, whereas blood flow to the forearm and calf was measured using strain gauge plethysmography. 3. The mean blood flow to different muscles ranged from 1.4 +/- 0.6 (gastrocnemius) to 1.8 +/- 0.7 (forearm extensor) ml min-1 100 g-1 muscle (1.4 +/- 0.6 and 1.9 +/- 0.8 ml min-1 100 ml-1 muscle, respectively) but there were no significant differences between them. Forearm and calf blood flows (2.7 +/- 0.3 and 3.0 +/- 0.7 ml min-1 100 ml-1 limb tissue, respectively) were about 50% to more than 100% greater (P muscles within them (1.7 +/- 0.5 and 1.4 +/- 0.5 ml min-1 100 g-1 muscle, respectively, or 1.8 +/- 0.6 and 1.5 +/- 0.5 ml min-1 100 ml-1 muscle, respectively). In contrast, the blood flows to 100 g of forearm skin (9.1 +/- 2.6 ml min-1 100 g-1) and adipose tissue (3.8 +/- 1.1 ml min-1 100 g-1) were higher than the blood flow to 100 g of forearm (P < 0.01 and not significant, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

  8. LED-Based Optical Device for Chronic In Vivo Cerebral Blood Volume Measurement.

    Science.gov (United States)

    Cox, Marshall P; Ma, Hongtao; Bahlke, Matthias E; Beck, Jonathan H; Schwartz, Theodore H; Kymissis, Ioannis

    2010-01-01

    We demonstrate a reflectivity-based cerebral blood volume sensor comprised of surface-mount light-emitting diodes on a flexible substrate with integrated photodetectors in a form factor suitable for direct brain contact and chronic implantation. This reflectivity monitor is able to measure blood flow through the change of the surface reflectivity and, through this mechanism, detect the cerebral-blood-volume changes associated with epileptic seizures with a signal-to-noise (SNR) response of 42 dB. The device is tested in an in vivo model confirming its compatibility and sensitivity. The data taken demonstrate that placing the sensor into direct brain contact improves the SNR by more than four orders of magnitude over current noncontact technologies.

  9. A 2D nonlinear multiring model for blood flow in large elastic arteries

    Science.gov (United States)

    Ghigo, Arthur R.; Fullana, Jose-Maria; Lagrée, Pierre-Yves

    2017-12-01

    In this paper, we propose a two-dimensional nonlinear ;multiring; model to compute blood flow in axisymmetric elastic arteries. This model is designed to overcome the numerical difficulties of three-dimensional fluid-structure interaction simulations of blood flow without using the over-simplifications necessary to obtain one-dimensional blood flow models. This multiring model is derived by integrating over concentric rings of fluid the simplified long-wave Navier-Stokes equations coupled to an elastic model of the arterial wall. The resulting system of balance laws provides a unified framework in which both the motion of the fluid and the displacement of the wall are dealt with simultaneously. The mathematical structure of the multiring model allows us to use a finite volume method that guarantees the conservation of mass and the positivity of the numerical solution and can deal with nonlinear flows and large deformations of the arterial wall. We show that the finite volume numerical solution of the multiring model provides at a reasonable computational cost an asymptotically valid description of blood flow velocity profiles and other averaged quantities (wall shear stress, flow rate, ...) in large elastic and quasi-rigid arteries. In particular, we validate the multiring model against well-known solutions such as the Womersley or the Poiseuille solutions as well as against steady boundary layer solutions in quasi-rigid constricted and expanded tubes.

  10. Rheology of Human Blood, near and at Zero Flow

    Science.gov (United States)

    Merrill, E. W.; Gilliland, E. R.; Cokelet, G.; Shin, H.; Britten, A.; Wells, R. E.

    1963-01-01

    Static normal human blood possesses a distinctive yield stress. When the yield stress is exceeded, the same blood has a stress-shear rate function under creeping flow conditions closely following Casson's model, which implies reversible aggregation of red cells in rouleaux and flow dominated by movement of rouleaux. The yield stress is essentially independent of temperature and its cube root varies linearly with hematocrit value. The dynamic rheological properties in the creeping flow range are such that the relative viscosity of blood to water is almost independent of temperature. Questions raised by these data are discussed, including red cell aggregation promoted by elements in the plasma. PMID:13935042

  11. Increased arterial wall stiffness limits flow volume in the lower extremities in type 2 diabetic patients.

    Science.gov (United States)

    Suzuki, E; Kashiwagi, A; Nishio, Y; Egawa, K; Shimizu, S; Maegawa, H; Haneda, M; Yasuda, H; Morikawa, S; Inubushi, T; Kikkawa, R

    2001-12-01

    To document an association between arterial wall stiffness and reduced flow volume in the lower-extremity arteries of diabetic patients. We recruited 60 consecutive type 2 diabetic patients who had no history or symptoms of peripheral arterial disease (PAD) in the lower extremities and normal ankle/brachial systolic blood pressure index at the time of the study (non-PAD group) and 20 age-matched nondiabetic subjects (control group). We used an automatic device to measure pulse wave velocity (PWV) in the lower extremities as an index of arterial wall stiffness. At the popliteal artery, we evaluated flow volume and the resistive index as an index of arterial resistance to blood flow using gated two-dimensional cine-mode phase-contrast magnetic resonance imaging. Consistent with previous reports, we confirmed that the non-PAD group had an abnormally higher PWV compared with that of the control group (P lower extremities of diabetic patients.

  12. Altitude acclimatization and blood volume: effects of exogenous erythrocyte volume expansion

    DEFF Research Database (Denmark)

    Sawka, M N; Young, Jette Feveile; Rock, P B

    1996-01-01

    We studied sea-level residents during 13 days of altitude acclimatization to determine 1) altitude acclimatization effects on erythrocyte volume and plasma volume, 2) if exogenous erythrocyte volume expansion alters subsequent erythrocyte volume and plasma volume adaptations, 3) if an increased...... blood oxygen content alters erythropoietin responses during altitude acclimatization, and 4) mechanisms responsible for plasma loss at altitude. Sixteen healthy men had a series of hematologic measurements made at sea level, on the first and ninth days of altitude (4,300 m) residence, and after...... returning to sea level. Twenty-four hours before the ascent to altitude, one group received a 700-ml infusion of autologous erythrocytes (42% hematocrit), whereas the other group received only a saline infusion. Erythrocyte infusion increased erythrocyte volume by approximately 10%, whereas saline infusion...

  13. Regulation of exercise blood flow: Role of free radicals.

    Science.gov (United States)

    Trinity, Joel D; Broxterman, Ryan M; Richardson, Russell S

    2016-09-01

    During exercise, oxygen and nutrient rich blood must be delivered to the active skeletal muscle, heart, skin, and brain through the complex and highly regulated integration of central and peripheral hemodynamic factors. Indeed, even minor alterations in blood flow to these organs have profound consequences on exercise capacity by modifying the development of fatigue. Therefore, the fine-tuning of blood flow is critical for optimal physical performance. At the level of the peripheral circulation, blood flow is regulated by a balance between the mechanisms responsible for vasodilation and vasoconstriction. Once thought of as toxic by-products of in vivo chemistry, free radicals are now recognized as important signaling molecules that exert potent vasoactive responses that are dependent upon the underlying balance between oxidation-reduction reactions or redox balance. Under normal healthy conditions with low levels of oxidative stress, free radicals promote vasodilation, which is attenuated with exogenous antioxidant administration. Conversely, with advancing age and disease where background oxidative stress is elevated, an exercise-induced increase in free radicals can further shift the redox balance to a pro-oxidant state, impairing vasodilation and attenuating blood flow. Under these conditions, exogenous antioxidants improve vasodilatory capacity and augment blood flow by restoring an "optimal" redox balance. Interestingly, while the active skeletal muscle, heart, skin, and brain all have unique functions during exercise, the mechanisms by which free radicals contribute to the regulation of blood flow is remarkably preserved across each of these varied target organs. Published by Elsevier Inc.

  14. Whole blood viscosity and cerebral blood flow velocities in obese hypertensive or obese normotensive adolescents.

    Science.gov (United States)

    Akcaboy, Meltem; Nazliel, Bijen; Goktas, Tayfun; Kula, Serdar; Celik, Bülent; Buyan, Necla

    2018-01-26

    Obesity affects all major organ systems and leads to increased morbidity and mortality. Whole blood viscosity is an important independent regulator of cerebral blood flow. The aim of the present study was to evaluate the effect of whole blood viscosity on cerebral artery blood flow velocities using transcranial Doppler ultrasound in pediatric patients with obesity compared to healthy controls and analyze the effect of whole blood viscosity and blood pressure status to the cerebral artery blood flow velocities. Sixty patients with obesity diagnosed according to their body mass index (BMI) percentiles aged 13-18 years old were prospectively enrolled. They were grouped as hypertensive or normotensive according to their ambulatory blood pressure monitoring. Whole blood viscosity and middle cerebral artery velocities by transcranial Doppler ultrasound were studied and compared to 20 healthy same aged controls. Whole blood viscosity values in hypertensive (0.0619±0.0077 poise) and normotensive (0.0607±0.0071 poise) groups were higher than controls (0.0616±0.0064 poise), with no significance. Middle cerebral artery blood flow velocities were higher in the obese hypertensive (73.9±15.0 cm/s) and obese normotensive groups (75.2±13.5 cm/s) than controls (66.4±11.5 cm/s), but with no statistical significance. Physiological changes in blood viscosity and changes in blood pressure did not seem to have any direct effect on cerebral blood flow velocities, the reason might be that the cerebral circulation is capable of adaptively modulating itself to changes to maintain a uniform cerebral blood flow.

  15. [Ocular blood flow and retinal electrogenesis in retinitis pigmentosa].

    Science.gov (United States)

    Kiseleva, T N; Zol'nikova, I V; Demenkova, O N; Ramazanova, K A; Egorova, I V; Rogatina, E V; Rogova, S Yu; Kiseleva, T N; Zol'nikova, I V; Demenkova, O N; Ramazanova, K A; Egorova, I V; Rogatina, E V; Rogova, S Yu

    2015-01-01

    to investigate correlations between changes in ocular hemodynamics revealed by color Doppler flow mapping (CDFM) and pulsed-wave (PW) Doppler imaging, one the one hand, and electrical activity of the retina, on the other, in patients with early, moderate, and severe retinitis pigmentosa (RP). A total of 20 patients (40 eyes) aged from 16 to 40 years (28.4 ± 8.2 years on average) with retinitis pigmentosa were enrolled. The control group consisted of 20 healthy volunteers of the same age range. All participants underwent full-field electroretinography (ERG), flicker ERG, and macular ERG as well as blood flow assessment in the ophthalmic artery (OA), central retinal artery (CRA), and short posterior ciliary arteries (SPCA) by means of CDFM and PW-Doppler. Ocular blood flow in CRA and SPCA appeared disturbed in patients with early RP. In cases of moderate and severe RP, the peak systolic velocity of CRA and SPCA blood flow was significantly decreased. Systolic and end diastolic blood flow velocities in CRA and SPCA has been shown to be directly related to full-field ERG a-wave and b-wave amplitudes, correspondingly, but negatively correlated with their implicit times. The revealed decrease in CRA and SPCA blood flow indices proves retinal and choroidal circulation deficit in patients with advanced RP. As shown, moderate blood flow changes are already present in early RP and progress as retinal photoreceptors and bipolar cells become suppressed, which may be useful for RP diagnosis and monitoring.

  16. Quantitative myocardial blood flow with Rubidium-82 PET

    DEFF Research Database (Denmark)

    Hagemann, Christoffer E; Ghotbi, Adam A; Kjær, Andreas

    2015-01-01

    Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1......) identification of the extent of a multivessel coronary artery disease (CAD) burden, 2) patients with balanced 3-vessel CAD, 3) patients with subclinical CAD, and 4) patients with regional flow variance, despite of a high global MFR. A more accurate assessment of the ischemic burden in patients with intermediate...

  17. Fractional-Step, Finite-Volume Computation Of Flow

    Science.gov (United States)

    Kwak, Dochan; Rosenfeld, Moshe; Vinokur, Marcel

    1992-01-01

    Method of solving Navier-Stokes equations of incompressible flow in general nonorthogonal curvilinear coordinates incorporates fractional-step and finite-volume approaches. Developed in continuing effort to achieve accuracy without need for excessive computation time in numerical simulation of time-dependent, three-dimensional flows bounded by surfaces of complicated shape.

  18. Peripheral blood flow control in diabetes mellitus

    DEFF Research Database (Denmark)

    Hilsted, Jannik

    1991-01-01

    . Whereas the hemodynamic consequences of vascular denervation are well known (causing blood pressure maladaptation to a number of stimuli such as standing, exercise and agonist infusion) (Hilsted 1985), the consequences of disturbances in autoregulation and distensibility remain to be established....

  19. Quantitative analysis of normal fetal medulla oblongata volume and flow by three-dimensional power Doppler ultrasound.

    Science.gov (United States)

    Shyu, Ing-Luen; Wang, Peng-Hui; Chen, Chih-Yao; Chen, Yi-Jen; Chang, Chia-Ming; Horng, Huann-Cheng; Yang, Ming-Jie; Yen, Ming-Shyen

    2016-06-01

    Assessment of the fetal medulla oblongata volume (MOV) and blood flow might be important in the evaluation of fetal brain growth. We used three-dimensional power Doppler ultrasound (3DPDUS) to assess the fetal MOV and blood flow index in normal gestation. The relationships between these parameters were further analyzed. We assessed the total volume and blood flow index of the fetal MO in normal pregnancies using a 3DPDUS (Voluson 730 Expert). The true sagittal plane over the fetal occipital area was measured by a 3D transabdominal probe to scan the fetal MO under the power Doppler mode. Then, we quantitatively assessed the total volume of the fetal MOV, mean gray area (MG), vascularization index (VI), and flow index (FI). A total of 106 fetuses, ranging from 19 weeks to 39 weeks of gestation, were involved in our study. The volume of the fetal MO was highly positively correlated with gestational age [correlation coefficient (r) = 0.686, p flow development quantitatively. Our study indicated that fetal MOV and blood flow correlated significantly with the advancement of gestational age. This information may serve as reference data for further studies of the fetal brain and blood flow under abnormal conditions. Copyright © 2016. Published by Elsevier B.V.

  20. Platelet function investigation by flow cytometry: Sample volume, needle size, and reference intervals.

    Science.gov (United States)

    Pedersen, Oliver Heidmann; Nissen, Peter H; Hvas, Anne-Mette

    2017-09-29

    Flow cytometry is an increasingly used method for platelet function analysis because it has some important advantages compared with other platelet function tests. Flow cytometric platelet function analyses only require a small sample volume (3.5 mL); however, to expand the field of applications, e.g., for platelet function analysis in children, even smaller volumes are needed. Platelets are easily activated, and the size of the needle for blood sampling might be of importance for the pre-activation of the platelets. Moreover, to use flow cytometry for investigation of platelet function in clinical practice, a reference interval is warranted. The aims of this work were 1) to determine if small volumes of whole blood can be used without influencing the results, 2) to examine the pre-activation of platelets with respect to needle size, and 3) to establish reference intervals for flow cytometric platelet function assays. To examine the influence of sample volume, blood was collected from 20 healthy individuals in 1.0 mL, 1.8 mL, and 3.5 mL tubes. To examine the influence of the needle size on pre-activation, blood was drawn from another 13 healthy individuals with both a 19- and 21-gauge needle. For the reference interval study, 78 healthy adults were included. The flow cytometric analyses were performed on a NAVIOS flow cytometer (Beckman Coulter, Miami, Florida) investigating the following activation-dependent markers on the platelet surface; bound-fibrinogen, CD63, and P-selectin (CD62p) after activation with arachidonic acid, ristocetin, adenosine diphosphate, thrombin-receptor-activating-peptide, and collagen. The study showed that a blood volume as low as 1.0 mL can be used for platelet function analysis by flow cytometry and that both a 19- and 21-gauge needle can be used for blood sampling. In addition, reference intervals for platelet function analyses by flow cytometry were established.

  1. Reduced myocardial blood flow in acute and chronic digitalization.

    Science.gov (United States)

    Steiness, E; Bille-Brahe, N E; Hansen, J F; Lomholt, N; Ring-Larsen, H

    1978-07-01

    The myocardial blood flow was measured by the 133Xenon disappearance curve from the left ventricular wall following an injection of 133Xenon in the left coronary artery in 8 dogs without digoxin pretreatment and in 8 chronically digitalized dogs. The myocardial blood flow was significantly less (30%) in the digitalized dogs than in the dogs without pretreatment. In the digitalized dogs as well as in those without pretreatment an intravenous injection of digoxin resulted in a further significant decrease of the myocardial blood flow of about 20% and a significant increase of the coronary vascular resistance. The reduced myocardial blood flow both during acute and chronic digitalization is beleived to be of clinical importance.

  2. Functional Imaging of Dolphin Brain Metabolism and Blood Flow

    National Research Council Canada - National Science Library

    Ridgway, Sam; Finneran, James; Carder, Don; Keogh, Mandy; Van Bonn, William; Smith, Cynthia; Scadeng, Miriam; Dubowitz, David; Mattrey, Robert; Hoh, Carl

    2006-01-01

    .... Diazepam has been shown to induce unihemispheric slow waves (USW), therefore we used functional imaging of dolphins with and without diazepam to observe hemispheric differences in brain metabolism and blood flow...

  3. Blood flow-vessel interaction in a subclavian aneurysm

    Directory of Open Access Journals (Sweden)

    Alexandru M. MOREGA

    2011-12-01

    Full Text Available This paper presents a mathematical mode and numerical simulation results of the blood flow-structural interaction, which occurs in a saccular aneurysm emerging out of the left subclavian artery, using computational domains made of by medical images reconstruction. A correlation between the total force per area acting upon the artery walls by the pulsatile blood flow and the rupture probability are also investigated.

  4. Blood flow boosts BMP signaling to keep vessels in shape.

    Science.gov (United States)

    Franco, Claudio A; Gerhardt, Holger

    2016-09-26

    Bone morphogenic proteins (BMPs) and blood flow regulate vascular remodeling and homeostasis. In this issue, Baeyens et al. (2016. J. Cell Biol http://dx.doi.org/10.1083/jcb.201603106) show that blood flow sensitizes endothelial cells to BMP9 signaling by triggering Alk1/ENG complexing to suppress cell proliferation and to recruit mural cells, thereby establishing endothelial quiescence. © 2016 Franco and Gerhardt.

  5. Effect of tropicamide on ocular blood flow in the rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Delgado, D.; Michel, P.; Jaanus, S.D.

    1982-05-01

    Intracardiac injection of 15 microspheres labeled with /sup 85/Sr (strontium) and /sup 141/Ce (cerium) were used to determine ocular blood flow in seven rabbits before and 25 min after bilateral application of tropicamide to the cornea. By using two different isotopes distinguishable under gammaspectrometry, each animal served as its own control. After administration of two drops of 1% tropicamide, no significant difference in blood flow between treated and untreated eyes was observed.

  6. Flow reproducibility of whole blood and other bodily fluids in simplified no reaction lateral flow assay devices.

    Science.gov (United States)

    Li, H; Han, D; Hegener, M A; Pauletti, G M; Steckl, A J

    2017-03-01

    The "no reaction" lateral flow assay (nrLFA) uses a simplified LFA structure with no conjugate pad and no stored reagents. In the nrLFA, the capillary-based transport time or distance is the key indicator, rather than the outcome of a biochemical reaction. Hence, the calibration and reproducibility of the nrLFA device are critical. The capillary flow properties of several membrane types (nitrocellulose, nylon, cellulose acetate, polyethersulfone, and polyvinylidene difluoride) are evaluated. Flow rate evaluations of MilliporeSigma Hi-Flow™ Plus (HF075, HF135 and HF180) nitrocellulose membranes on nrLFA are performed using bodily fluids (whole blood, blood plasma, and artificial sweat). The results demonstrate that fluids with lower viscosity travel faster, and membranes with slower flow rate exhibit higher capability to distinguish fluids with different viscosities. Reproducibility tests of nrLFA are performed on HF075, demonstrating excellent reproducibility. The coefficient of variation for blood coagulation tests performed with the nrLFA using induced coagulation was 5% for the plasma front and 2% for the RBC front. The effects of variation in blood hematocrit and sample volume are also reported. The overall results indicate that the nrLFA approach has a high potential to be commercially developed as a blood monitoring point-of-care device with simple calibration capability and excellent reproducibility.

  7. Blood flow and arterial endothelial dysfunction: Mechanisms and implications

    Science.gov (United States)

    Barakat, Abdul I.

    2013-06-01

    The arterial endothelium exquisitely regulates vascular function, and endothelial dysfunction plays a critical role in the development of atherosclerosis. Atherosclerotic lesions develop preferentially at arterial branches and bifurcations where the blood flow is disturbed. Understanding the basis for this observation requires elucidating the effects of blood flow on the endothelial cell (EC) function. The goal of this review is: (1) to describe our current understanding of the relationships between arterial blood flow and atherosclerosis, (2) to present the wide array of flow-induced biological responses in ECs, and (3) to discuss the mechanisms by which ECs sense, transmit, and transduce flow-derived mechanical forces. We conclude by presenting some future perspectives in the highly interdisciplinary field of EC mechanotransduction.

  8. Tubuloglomerular feedback dynamics and renal blood flow autoregulation in rats

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Wagner, A J; Marsh, D J

    1991-01-01

    To decide whether tubuloglomerular feedback (TGF) can account for renal autoregulation, we tested predictions of a TGF simulation. Broad-band and single-frequency perturbations were applied to arterial pressure; arterial blood pressure, renal blood flow and proximal tubule pressure were measured....... blood flow. We conclude that two components can be detected in the dynamic regulation of renal blood flow, i.e., a slow component that represents TGF and a faster component that most likely represents an intrinsic vascular myogenic mechanism.......To decide whether tubuloglomerular feedback (TGF) can account for renal autoregulation, we tested predictions of a TGF simulation. Broad-band and single-frequency perturbations were applied to arterial pressure; arterial blood pressure, renal blood flow and proximal tubule pressure were measured....... Data were analyzed by linear systems analysis. Broad-band forcings of arterial pressure were also applied to the model to compare experimental results with simulations. With arterial pressure as the input and tubular pressure, renal blood flow, or renal vascular resistance as outputs, the model...

  9. Decreasing the Uterine Blood Flow with Electroacupuncture: Bidermatomal and Monodermatomal Applications.

    Science.gov (United States)

    Cakmak, Yusuf Ozgur; Akpinar, Ihsan Nuri; Yoldemir, Tevfik

    2017-01-01

    Previously we demonstrated a uterine fibroma case in which the decrease in the uterine artery blood flow was obtained with bidermatomal electroacupuncture (EA). A prospective study was conducted to validate the efficacy of bidermatomal and monodermatomal EA applications. Ten healthy women participated 3 times for 3 steps of the study. Each woman enrolled into a bidermatomal sham control group application, a bidermatomal 80 Hz EA and as a last step, a monodermatomal EA with 80 Hz. Color Doppler ultrasonographic recordings were made to detect baseline blood flow parameters by a pulsatility index (PI), volume flow, area and diameter of each uterine artery and after stimulations. Doppler ultrasonographic recordings demonstrated statistically significant decreases of the blood flow both with bidermatomal (p = 0.03 for the left side PI and p = 0.04 for the right side PI) and monodermatomal EA (p = 0.006 for the left PI and p = 0.002 for the right side PI). The sham control group did not show a significant change in blood flow parameters. The present study validates the efficacy of the bidermatomal but also the monodermatomal EA with 80 Hz on decreasing the blood flow to the uterus. © 2016 S. Karger AG, Basel.

  10. Effect of stratified inequality of blood flow on gas exchange in liquid-filled lungs.

    Science.gov (United States)

    West, J. B.; Maloney, J. E.; Castle, B. L.

    1972-01-01

    This investigation set out to answer two questions: (1) are the distal alveoli in the terminal lung units less well perfused than the proximal alveoli, i.e., is there stratification of blood flow; and (2) if so, does this enhance gas exchange in the presence of stratified inequality of ventilation. Excised dog lungs were ventilated with saline and perfused with blood. Following single inspirations of xenon 133 in saline and various periods of breath holding, the expired xenon concentration against volume was measured and it confirmed marked stratified inequality of ventilation under these conditions. By measuring the rate of depletion of xenon from alveoli during a period of blood flow, we showed that the alveoli which emptied at the end of expiration had 16% less blood flow than those exhaling earlier. However, by measuring the xenon concentration in pulmonary venous blood, we found that about 10% less tracer was transferred from the alveoli into the blood when the inspired xenon was stratified within the respiratory zone. Thus while stratification of blood flow was confirmed, it was shown to impair rather than enhance the efficiency of gas transfer.

  11. Computational model on pulsatile flow of blood through a tapered ...

    Indian Academy of Sciences (India)

    An unsteady two-fluid model of blood flow through a tapered arterial stenosis with variable viscosity in the presence of variable magnetic field has been analysed in the present paper. In this article, blood in the core region is assumed to obey the law of Jeffrey fluid and plasma in the peripheral layer is assumed to be ...

  12. Calculating Study of the Turbine at Last Stage Flow Field in the Small Volume Flow Condition

    Directory of Open Access Journals (Sweden)

    Jiang Tieliu

    2017-11-01

    Full Text Available Based on basic equation and boundary layer theory of pneumodynamics, the thesis conducts numerical modeling and theoretical analysis on the last stage of turbine characteristics at a small volume flow by using FLUENT, gives an emphasized analysis on the position of first occurrence of backflow and its expansion direction and comes up with flow structure of the turbine flow field at last stage in the small volume flow condition. In connection with specific experiments, it puts forward the flow model of backflow occurring in the last stage field and the solution to the model. The flow field at last stage for a 100MW turbine in the small volume flow condition that is calculated by using the model is basically in conformity to the actual result.

  13. Real-time contrast-enhanced ultrasound determination of microvascular blood volume in abdominal subcutaneous adipose tissue in man. Evidence for adipose tissue capillary recruitment

    DEFF Research Database (Denmark)

    Tobin, L; Simonsen, L; Bülow, J

    2010-01-01

    The adipose tissue metabolism is dependent on its blood perfusion. During lipid mobilization e.g. during exercise and during lipid deposition e.g. postprandial, adipose tissue blood flow is increased. This increase in blood flow may involve capillary recruitment in the tissue. We investigated...... of ultrasound contrast agent to establish the reproducibility of the technique. In nine subjects, the effect of an oral glucose load on blood flow and microvascular volume was measured in abdominal subcutaneous adipose tissue and forearm skeletal muscle. ¹³³Xe washout and venous occlusion strain...... with a 4% coefficient of variation in both tissues. Blood flow and the change in signal intensity as a measure of the microvascular volume increased significantly and simultaneously in abdominal subcutaneous adipose tissue after glucose intake. The forearm blood flow and muscle signal intensity remained...

  14. Comparison of extracapillary and endocapillary blood flow oxygenators for open heart surgery in dogs: efficiency of gas exchange and platelet conservation.

    Science.gov (United States)

    Hoshi, Katsuichiro; Tanaka, Ryou; Shibazaki, Akira; Nagashima, Yukiko; Hirao, Hidehiro; Namiki, Ryosuke; Takashima, Kazuaki; Noishiki, Yasuharu; Yamane, Yoshihisa

    2003-03-01

    The goal of the current study was to compare the efficiency of gas exchange and platelet conservation of a new extracapillary blood flow oxygenator versus an endocapillary blood flow oxygenator during open heart surgery with extracorporeal circulation in dogs. Dilation and remodeling of the right ventricular outflow tract of dogs was performed using a patch graft technique to simulate pulmonary stenosis. Sequential pre- and post-operative blood analysis revealed that gas exchange efficiency and platelet conservation was significantly greater with the extracapillary blood flow oxygenator than with the endocapillary blood flow oxygenator. However, the priming volume of the extracapillary blood flow oxygenator was significantly greater, leading to hemodilution. We conclude that while the extracapillary blood flow oxygenator provided benefits in terms of gas exchange and platelet conservation, development of a smaller extracapillary blood flow type oxygenator to reduce hemodilution effects would be beneficial.

  15. Blood flow and clearance in tendons. Studies with dogs.

    Science.gov (United States)

    Hooper, G; Davies, R; Tothill, P

    1984-05-01

    Blood flow in intact tendons in dogs was measured using 57Co-labelled microspheres and compared with the simultaneous clearance of a diffusible radionuclide, 85Sr, by the same tendons. Clearance was significantly greater than flow in all tendons, indicating that diffusion from surrounding tissues may be important in the nutrition of normal tendons.

  16. Methods for measurement of cerebral blood flow in man

    DEFF Research Database (Denmark)

    Lassen, N A

    1976-01-01

    A survey of the currently available methods for the measurement of cerebral blood flow in man is given. Many of the clinically important brain diseases such as tumors, stroke, brain trauma or epilepsy entail focal or regional flow alterations. Therefore a special emphasis is placed on methods all...

  17. Oesophageal heat transfer properties indication of segmental blood flow changes during distension

    DEFF Research Database (Denmark)

    Liao, Donghua; Frøkjær, Jens Brøndum; Brock, Christina

    2008-01-01

    The pain perception to distension of the oesophagus can be explained by activation of receptors responding to mechanical deformation or to distension-induced ischaemia. The aim of this study was to develop a new method for detection of changes in segmental blood flow during distension based...... transfer during cooling was not affected by the bag volume (F = 0.9, P = 0.4). The findings indicate that segmental blood flow can be assessed indirectly by calculating the heat transfer properties. Distension induced a drop in regional blood flow. Hence, ischaemia may contribute to distension-induced pain...... on measurement of heat transfer. A bag was distended in the distal oesophagus of six healthy subjects followed by cooling or heating of the bag fluid to 5 or 60 degrees C. After equilibrium, the temperature was allowed to change back to body temperature. The temperature was recorded together with intraluminal...

  18. Ultrasonic Enrichment of Flowing Blood Cells in Capillars: Influence of the Flow Rate

    Science.gov (United States)

    Carreras, Pilar; Gonzalez, Itziar; Ahumada, Oscar

    Red blood cells subjected to standing waves collect at the pressure nodes during their flow motion. Blood is a non-newtonian fluid whose density and other properties are defined by its flow velocity. Their drift motion is governed by the radiation force together with hydrodynamic conditions. This work presents a study of the blood cell enrichment performed in a rectangular capillar at f=1 MHz as a function of their flow motion. The cells collect along the central axis of the capillary in very few seconds, with a clearance in other lateral areas. Optimal flow rates below 100uL/min were found in the experiments.

  19. CHARACTERIZATION OF RENAL BLOOD FLOW REGULATION BASED ON WAVELET COEFFICIENTS

    DEFF Research Database (Denmark)

    Pavlov, A.N.; Pavlova, O.N.; Mosekilde, Erik

    2010-01-01

    The purpose of this study is to demonstrate the possibility of revealing new characteristic features of renal blood flow autoregulation in healthy and pathological states through the application of discrete wavelet transforms to experimental time series for normotensive and hypertensive rats....... A reduction in the variability of the wavelet coefficients in hypertension is observed at both the microscopic level of the blood flow in efferent arterioles of individual nephrons and at the macroscopic level of the blood pressure in the main arteries. The reduction is manifest in both of the main frequency...

  20. Vasodilator interactions in skeletal muscle blood flow regulation

    DEFF Research Database (Denmark)

    Hellsten, Ylva; Nyberg, Michael Permin; Jensen, Lasse Gliemann

    2012-01-01

    During exercise, oxygen delivery to skeletal muscle is elevated to meet the increased oxygen demand. The increase in blood flow to skeletal muscle is achieved by vasodilators formed locally in the muscle tissue, either on the intraluminal or the extraluminal side of the blood vessels. A number...... that this remaining hyperemia may be explained by cAMP and cGMP independent smooth muscle relaxation, such as effects of endothelial derived hyperpolarization factors (EDHFs) or through metabolic modulation of sympathetic effects. The nature and role of EDHF as well as potential novel mechanisms in muscle blood flow...

  1. Mesenteric stenosis, collaterals, and compensatory blood flow

    NARCIS (Netherlands)

    van Petersen, Andre S.; Kolkman, Jeroen J.; Meerwaldt, Robbert; Huisman, Ad B.; van der Palen, Jacobus Adrianus Maria; Zeebregts, Clark J.; Geelkerken, Robert H.

    2014-01-01

    Background The mesenteric circulation has an extensive collateral network. Therefore, stenosis in one or more mesenteric arteries does not necessarily lead to symptoms. The objective of this study was to determine the effect of collateral flow on celiac artery (CA) and superior mesenteric artery

  2. Mesenteric stenosis, collaterals, and compensatory blood flow

    NARCIS (Netherlands)

    van Petersen, Andre S.; Kolkman, Jeroen J.; Meerwaldt, Robbert; Huisman, Ad B.; van der Palen, Job; Zeebregts, Clark J.; Geelkerken, Robert H.

    Background: The mesenteric circulation has an extensive collateral network. Therefore, stenosis in one or more mesenteric arteries does not necessarily lead to symptoms. The objective of this study was to determine the effect of collateral flow on celiac artery (CA) and superior mesenteric artery

  3. Estimating blood flow velocity in angiographic image data

    Science.gov (United States)

    Hentschke, Clemens M.; Serowy, Steffen; Janiga, Gábor; Rose, Georg; Tönnies, Klaus D.

    2011-03-01

    We propose a system to estimate blood flow velocity in angiographic image data for patient-specific blood flow simulations. Angiographies are acquired routinely for diagnosis and before treatment of vascular diseases. Projective blood flow is measured in digital subtraction X-ray angiography (2D-DSA) images by tracking contrast agent propagation. Spatial information is added by re-projecting 2D centerline pixels to the reconstructed 3D X-ray rotation angiography (3D-RA) data of the same subject. Ambiguities caused by occluding vessels from the virtual viewpoint of the acquired 2D-DSA image are resolved by a graph-based approach. The blood flow velocity can be used as boundary condition for exact blood flow simulations that can help physicians to understand hemodynamics of the vasculature. Our focus is to analyze cerebral angiographic data. We performed several experiments with phantom and patient data that proved the accuracy and the functionality of our method. We evaluated experimentally the projective flow estimation method and the re-projection method. We measured mean deviations to the ground truth between 11 % and 15.7 % for phantom data. We also showed the ability of our method to produce plausible results with patient-data.

  4. Geometric analysis and blood flow simulation of basilar artery.

    Science.gov (United States)

    Lee, Sang Hyuk; Hur, Nahmkeon; Jeong, Seul-Ki

    2012-01-01

    The aim of this study was to find a region of low wall shear stress (WSS) in a basilar artery using 3-dimensional (3D) geometric analysis and blood flow simulation. A 61-year-old patient who underwent follow-up time-of-flight magnetic resonance angiography (TOF-MRA) of the brain was recruited as the subject of the present study. In the basilar artery, the angle of the directional vector was calculated for the region of low WSS. The subject's 3D arterial geometry and blood flow velocity from a transcranial Doppler examination were used for a blood flow simulation study. The regions of low WSS identified by both geometric analysis and blood flow simulation were compared, and these methods were repeated for the basilar arteries of various geometries from other patients. Two distinct arterial angulations along the basilar artery were identified: lateral and anterior angulations on the anteroposterior and lateral TOF-MR views, respectively. A low WSS region was observed in the distal portion along the inner curvatures of both angulations in the basilar artery. The directional vectors of the region of low WSS calculated by geometric analysis and blood flow simulation were very similar (correlation coefficient= 0.996, p flow simulation of the basilar artery identified lateral and anterior angulations which determined the low WSS region in the distal portion along the inner curvatures of the angulations.

  5. Accuracy of a new bedside method for estimation of circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Waever Rasmussen, J; Winther Henneberg, S

    1993-01-01

    To evaluate the accuracy of a modification of the carbon monoxide method of estimating the circulating blood volume.......To evaluate the accuracy of a modification of the carbon monoxide method of estimating the circulating blood volume....

  6. Viscoelastic capillary flow: the case of whole blood

    Directory of Open Access Journals (Sweden)

    David Rabaud

    2016-07-01

    Full Text Available The dynamics of spontaneous capillary flow of Newtonian fluids is well-known and can be predicted by the Lucas-Washburn-Rideal (LWR law. However a wide variety of viscoelastic fluids such as alginate, xanthan and blood, does not exhibit the same Newtonian behavior.In this work we consider the Herschel-Bulkley (HB rheological model and Navier-Stokes equation to derive a generic expression that predicts the capillary flow of non-Newtonian fluids. The Herschel-Bulkley rheological model encompasses a wide variety of fluids, including the Power-law fluids (also called Ostwald fluids, the Bingham fluids and the Newtonian fluids. It will be shown that the proposed equation reduces to the Lucas-Washburn-Rideal law for Newtonian fluids and to the Weissenberg-Rabinowitsch-Mooney (WRM law for power-law fluids. Although HB model cannot reduce to Casson’s law, which is often used to model whole blood rheology, HB model can fit the whole blood rheology with the same accuracy.Our generalized expression for the capillary flow of non-Newtonian fluid was used to accurately fit capillary flow of whole blood. The capillary filling of a cylindrical microchannel by whole blood was monitored. The blood first exhibited a Newtonian behavior, then after 7 cm low shear stress and rouleaux formation made LWR fails to fit the data: the blood could not be considered as Newtonian anymore. This non-Newtonian behavior was successfully fit by the proposed equation.

  7. Nephron blood flow dynamics measured by laser speckle contrast imaging

    DEFF Research Database (Denmark)

    von Holstein-Rathlou, Niels-Henrik; Sosnovtseva, Olga V; Pavlov, Alexey N

    2011-01-01

    Tubuloglomerular feedback (TGF) has an important role in autoregulation of renal blood flow and glomerular filtration rate (GFR). Because of the characteristics of signal transmission in the feedback loop, the TGF undergoes self-sustained oscillations in single-nephron blood flow, GFR, and tubular...... pressure and flow. Nephrons interact by exchanging electrical signals conducted electrotonically through cells of the vascular wall, leading to synchronization of the TGF-mediated oscillations. Experimental studies of these interactions have been limited to observations on two or at most three nephrons...... simultaneously. The interacting nephron fields are likely to be more extensive. We have turned to laser speckle contrast imaging to measure the blood flow dynamics of 50-100 nephrons simultaneously on the renal surface of anesthetized rats. We report the application of this method and describe analytic...

  8. Blood flow and stem cells in vascular disease.

    Science.gov (United States)

    Zhang, Cheng; Zeng, Lingfang; Emanueli, Costanza; Xu, Qingbo

    2013-07-15

    It is well known that the altered blood flow is related to vascular diseases, including atherosclerosis, restenosis, and arteriosclerosis, which preferentially located at areas with the disturbed blood flow, suggesting that altered biomechanical stress may exert their effect on the vascular disease. Recent evidence indicated the presence of abundant stem/progenitor cells in the vessel wall, in which laminar shear stress can stimulate these cells to differentiate towards endothelial lineage, while cyclic strain results in smooth muscle differentiation. In line with this, it was evidenced that altered biomechanical stress in stented vessels may lead to 'wrong' direction of vascular stem cell differentiation resulting in restenosis. However, the underlying mechanisms are not well understood. In this article, we will give an overview of the effect of the local flow pattern on stem/progenitor cell differentiation and the possible mechanism on how the blood flow influences stem cell behaviours in the development of vascular diseases.

  9. Intrinsic regulation of blood flow in adipose tissue

    DEFF Research Database (Denmark)

    Henriksen, O; Nielsen, Steen Levin; Paaske, W

    1976-01-01

    Previous studies on intact human subcutaneous tissue have shown, that blood flow remains constant during minor changes in perfusion pressure. This so-called autoregulatory response has not been demonstrable in isolated preparations of adipose tissue. In the present study on isolated, denervated...... subcutaneous tissue in female rabbits only 2 of 12 expts. revealed an autoregulatory response during reduction in arterial perfusion pressure. Effluent blood flow from the tissue in the control state was 15.5 ml/100 g-min (S.D. 6.4, n = 12) corresponding to slight vasodilatation of the exposed tissue....... Following total ischemia all experiments showed a period with reactive hyperemia, and both duration of hyperemia and excess flow was related to the duration of the ischemia. This response therefore seems more resistant to the experimental procedure, while autoregulation of blood flow to lowered pressure...

  10. Pulsatile blood flow, shear force, energy dissipation and Murray's Law

    Directory of Open Access Journals (Sweden)

    Bengtsson Hans-Uno

    2006-08-01

    Full Text Available Abstract Background Murray's Law states that, when a parent blood vessel branches into daughter vessels, the cube of the radius of the parent vessel is equal to the sum of the cubes of the radii of daughter blood vessels. Murray derived this law by defining a cost function that is the sum of the energy cost of the blood in a vessel and the energy cost of pumping blood through the vessel. The cost is minimized when vessel radii are consistent with Murray's Law. This law has also been derived from the hypothesis that the shear force of moving blood on the inner walls of vessels is constant throughout the vascular system. However, this derivation, like Murray's earlier derivation, is based on the assumption of constant blood flow. Methods To determine the implications of the constant shear force hypothesis and to extend Murray's energy cost minimization to the pulsatile arterial system, a model of pulsatile flow in an elastic tube is analyzed. A new and exact solution for flow velocity, blood flow rate and shear force is derived. Results For medium and small arteries with pulsatile flow, Murray's energy minimization leads to Murray's Law. Furthermore, the hypothesis that the maximum shear force during the cycle of pulsatile flow is constant throughout the arterial system implies that Murray's Law is approximately true. The approximation is good for all but the largest vessels (aorta and its major branches of the arterial system. Conclusion A cellular mechanism that senses shear force at the inner wall of a blood vessel and triggers remodeling that increases the circumference of the wall when a shear force threshold is exceeded would result in the observed scaling of vessel radii described by Murray's Law.

  11. Partitioning of red blood cell aggregates in bifurcating microscale flows

    Science.gov (United States)

    Kaliviotis, E.; Sherwood, J. M.; Balabani, S.

    2017-03-01

    Microvascular flows are often considered to be free of red blood cell aggregates, however, recent studies have demonstrated that aggregates are present throughout the microvasculature, affecting cell distribution and blood perfusion. This work reports on the spatial distribution of red blood cell aggregates in a T-shaped bifurcation on the scale of a large microvessel. Non-aggregating and aggregating human red blood cell suspensions were studied for a range of flow splits in the daughter branches of the bifurcation. Aggregate sizes were determined using image processing. The mean aggregate size was marginally increased in the daughter branches for a range of flow rates, mainly due to the lower shear conditions and the close cell and aggregate proximity therein. A counterintuitive decrease in the mean aggregate size was apparent in the lower flow rate branches. This was attributed to the existence of regions depleted by aggregates of certain sizes in the parent branch, and to the change in the exact flow split location in the T-junction with flow ratio. The findings of the present investigation may have significant implications for microvascular flows and may help explain why the effects of physiological RBC aggregation are not deleterious in terms of in vivo vascular resistance.

  12. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan [Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States)

    2009-11-15

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  13. A volume-balance model for flow on porous media

    Science.gov (United States)

    Malaga, Carlos; Mandujano, Francisco; Becerra, Julian

    2015-11-01

    Volume-balance models are used by petroleum engineers for simulating multiphase and multicomponent flow phenomena in porous media and the extraction process in oil reservoirs. In these models, mass conservation equations and Darcy's law are supplemented by a balance condition for the pore and fluid volumes. This provides a pressure equation suitable for simulating a compressible flow within a compressible solid matrix. Here we present an alternative interpretation of the volume-balance condition that includes the advective transport within a consolidated porous media. We obtain a modified equation for the time evolution of the pressure field. Numerical tests for phase separation under gravity are presented for multiphase three dimensional flow in heterogeneous porous media. The authors acknowledge funding from Fondo Sectorial CONACYT-SENER grant number 42536 (DGAJ-SPI-34-170412-217).

  14. White Matter Hyperintensity Associations with Cerebral Blood Flow in Elderly Subjects Stratified by Cerebrovascular Risk.

    Science.gov (United States)

    Bahrani, Ahmed A; Powell, David K; Yu, Guoquiang; Johnson, Eleanor S; Jicha, Gregory A; Smith, Charles D

    2017-04-01

    This study aims to add clarity to the relationship between deep and periventricular brain white matter hyperintensities (WMHs), cerebral blood flow (CBF), and cerebrovascular risk in older persons. Deep white matter hyperintensity (dWMH) and periventricular white matter hyperintensity (pWMH) and regional gray matter (GM) and white matter (WM) blood flow from arterial spin labeling were quantified from magnetic resonance imaging scans of 26 cognitively normal elderly subjects stratified by cerebrovascular disease (CVD) risk. Fluid-attenuated inversion recovery images were acquired using a high-resolution 3-dimensional (3-D) sequence that reduced partial volume effects seen with slice-based techniques. dWMHs but not pWMHs were increased in patients at high risk of CVD; pWMHs but not dWMHs were associated with decreased regional cortical (GM) blood flow. We also found that blood flow in WM is decreased in regions of both pWMH and dWMH, with a greater degree of decrease in pWMH areas. WMHs are usefully divided into dWMH and pWMH regions because they demonstrate differential effects. 3-D regional WMH volume is a potentially valuable marker for CVD based on associations with cortical CBF and WM CBF. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Pulmonary blood volume and transit time in cirrhosis: relation to lung function

    DEFF Research Database (Denmark)

    Møller, Søren; Burchardt, H; Øgard, CG

    2006-01-01

    BACKGROUND/AIMS: In cirrhosis a systemic vasodilatation leads to an abnormal distribution of the blood volume with a contracted central blood volume. In addition, the patients have a ventilation/perfusion imbalance with a low diffusing capacity. As the size of the pulmonary blood volume (PBV) has...

  16. Coded ultrasound for blood flow estimation using subband processing

    DEFF Research Database (Denmark)

    Gran, F.; Udesen, J.; Jensen, J.A.

    2008-01-01

    This paper investigates the use of coded excitation for blood flow estimation in medical ultrasound. Traditional autocorrelation estimators use narrow-band excitation signals to provide sufficient signal-to-noise-ratio (SNR) and velocity estimation performance. In this paper, broadband coded...... the excitation signal is broadband and has good spatial resolution after pulse compression. This means that time can be saved by using the same data for B-mode imaging and blood flow estimation. Two different coding schemes are used in this paper, Barker codes and Golay codes. The performance of the codes...... for velocity estimation is compared with a conventional approach transmitting a narrow-band pulse. The study was carried out using an experimental ultrasound scanner and a commercial linear array 7 MHz transducer. A circulating flow rig was scanned with a beam-to-flow angle of 60 degrees. The flow in the rig...

  17. Coded Ultrasound for Blood Flow Estimation Using Subband Processing

    DEFF Research Database (Denmark)

    Gran, Fredrik; Udesen, Jesper; Nielsen, Michael Bachamnn

    2008-01-01

    This paper investigates the use of coded excitation for blood flow estimation in medical ultrasound. Traditional autocorrelation estimators use narrow-band excitation signals to provide sufficient signal-to-noise-ratio (SNR) and velocity estimation performance. In this paper, broadband coded...... the excitation signal is broadband and has good spatial resolution after pulse compression. This means that time can be saved by using the same data for B-mode imaging and blood flow estimation. Two different coding schemes are used in this paper, Barker codes and Golay codes. The performance of the codes...... for velocity estimation is compared with a conventional approach transmitting a narrow-band pulse. The study was carried out using an experimental ultrasound scanner and a commercial linear array 7 MHz transducer. A circulating flow rig was scanned with a beam-to-flow angle of 60°. The flow in the rig...

  18. Intermittent calf and foot compression increases lower extremity blood flow.

    Science.gov (United States)

    Eze, A R; Comerota, A J; Cisek, P L; Holland, B S; Kerr, R P; Veeramasuneni, R; Comerota, A J

    1996-08-01

    Although foot compression increases foot skin perfusion and calf compression increases popliteal artery blood flow, these compression techniques have not been evaluated in combination. The purpose of this study was to evaluate whether calf and foot compression applied separately and simultaneously increase popliteal artery blood flow and/or foot skin perfusion, and to assess the relative merits of compression in patients with superficial femoral artery occlusion. Twenty-two legs from 12 normal volunteers with ankle/brachial indices (ABIs) > 0.96, and 10 legs from 7 claudicator patients with angiographically documented superficial femoral artery (SFA) occlusion and patent popliteal arteries with ABIs pressure pump (Art-Assist-AA 1000; ACI Medical Inc., San Marcos, California) were applied to the subject in the sitting position. Skin blood flow of the great toe was measured with a laser doppler (Laserflo model BPM 403A; TSI Inc., St. Paul, Minnesota), and popliteal artery blood flow was measured using duplex ultrasonography (ATL-Ultramark 9; Advanced Tech Laboratory, Bothell, Washington). Foot and calf compression was applied separately and simultaneously at 120 mm Hg pressure, with a 10-second inflation and 20-second deflation cycle. Popliteal artery blood flow and foot skin perfusion were recorded and the mean of 6 cycles calculated. Precompression popliteal artery blood flow (mL/min) for volunteers was 38.86 +/- 3.94, and for patients was 86.30 +/- 14.55 (P = 0.001). Precompression foot skin perfusion (mL/min/ 100/g tissue) for volunteers was 1.67 +/- 0.29, and for patients was 4.00 +/- 0.92 (P = 0.01). With the application of calf, foot, and simultaneous calf and foot compression, the popliteal artery blood flow increased in volunteers by 124%, 54%, and 173%, respectively, and in patients by 76%, 13%, and 50%. Foot skin perfusion increased in volunteers by 260%, 500%, and 328%, respectively, and in patients by 116%, 246%, and 188%. Relative increases in popliteal

  19. Advanced Recording and Preprocessing of Physiological Signals. [data processing equipment for flow measurement of blood flow by ultrasonics

    Science.gov (United States)

    Bentley, P. B.

    1975-01-01

    The measurement of the volume flow-rate of blood in an artery or vein requires both an estimate of the flow velocity and its spatial distribution and the corresponding cross-sectional area. Transcutaneous measurements of these parameters can be performed using ultrasonic techniques that are analogous to the measurement of moving objects by use of a radar. Modern digital data recording and preprocessing methods were applied to the measurement of blood-flow velocity by means of the CW Doppler ultrasonic technique. Only the average flow velocity was measured and no distribution or size information was obtained. Evaluations of current flowmeter design and performance, ultrasonic transducer fabrication methods, and other related items are given. The main thrust was the development of effective data-handling and processing methods by application of modern digital techniques. The evaluation resulted in useful improvements in both the flowmeter instrumentation and the ultrasonic transducers. Effective digital processing algorithms that provided enhanced blood-flow measurement accuracy and sensitivity were developed. Block diagrams illustrative of the equipment setup are included.

  20. Regulation of blood volume in lowlanders exposed to high altitude.

    Science.gov (United States)

    Siebenmann, Christoph; Robach, Paul; Lundby, Carsten

    2017-10-01

    Humans ascending to high altitude (HA) experience a reduction in arterial oxyhemoglobin saturation and, as a result, arterial O2 content ([Formula: see text]). As HA exposure extends, this reduction in [Formula: see text] is counteracted by an increase in arterial hemoglobin concentration. Initially, hemoconcentration is exclusively related to a reduction in plasma volume (PV), whereas after several weeks a progressive expansion in total red blood cell volume (RCV) contributes, although often to a modest extent. Since the decrease in PV is more rapid and usually more pronounced than the expansion in RCV, at least during the first weeks of exposure, a reduction in circulating blood volume is common at HA. Although the regulation of hematological responses to HA has been investigated for decades, it remains incompletely understood. This is not only related to the large number of mechanisms that could be involved and the complexity of their interplay but also to the difficulty of conducting comprehensive experiments in the often secluded HA environment. In this review, we present our understanding of the kinetics, the mechanisms and the physiological relevance of the HA-induced reduction in PV and expansion in RCV. Copyright © 2017 the American Physiological Society.

  1. Effects of posture on limb blood flow in late pregnancy.

    Science.gov (United States)

    Drummond, G B; Scott, S E; Lees, M M; Scott, D B

    1974-06-15

    Arm and leg blood flow was measured in 40 patients in late pregnancy in the supine and left lateral positions, and the changes were contrasted with changes found in 15 patients investigated in the early puerperium. A significant reduction in leg flow occurred in the pregnant subjects when the supine position was assumed. A further 30 patients in late pregnancy had leg flow measured in the following positions: left lateral, supine, right lateral, and the two mid-positions. Leg flow significantly increased on moving from the supine to all other positions except the right intermediate position, indicating that a leftward tilt is more effective in preventing caval compression.

  2. Magnetic resonance imaging and measurement of blood flow.

    OpenAIRE

    McDonnell, C H; Herfkens, R J; Norbash, A M; Rubin, G D

    1994-01-01

    Blood flow can be shown as a negative image with magnetic resonance spin-echo techniques or as a positive image with gradient-echo techniques. Phase contrast refers to techniques where structures can be seen because of flow-induced phase shifts. These techniques can show the presence (slow flow) and also the direction of flow. Gradient-echo techniques--including phase-contrast versions--can be used with cardiac synchronization to obtain multiple images during the cardiac cycle. These images c...

  3. Flow features and device-induced blood trauma in CF-VADs under a pulsatile blood flow condition: A CFD comparative study.

    Science.gov (United States)

    Chen, Zengsheng; Jena, Sofen K; Giridharan, Guruprasad A; Koenig, Steven C; Slaughter, Mark S; Griffith, Bartley P; Wu, Zhongjun J

    2017-08-31

    In this study, the flow features and device-associated blood trauma in 4 clinical ventricular assist devices (VADs; 2 implantable axial VADs, 1 implantable centrifugal VAD, and 1 extracorporeal VAD) were computationally analyzed under clinically relevant pulsatile flow conditions. The 4 VADs were operated at fixed pump speed at a mean rate of 4.5 L/min. Mean pressure difference, wall shear stress, volume distribution of scalar shear stress (SSS), and shear-induced hemolysis index (HI) were derived from the flow field of each VAD and were compared. The computationally predicted mean pressure difference across the 3 implantable VADs was ~70 mmHg, and the extracorporeal VAD was ~345 mmHg, which matched well with their reported pressure-flow curves. The axial VADs had higher mean wall shear stress and SSS compared with the centrifugal VADs. However, the residence time of the centrifugal VADs was much longer compared with the axial VADs because of the large volume of the centrifugal VADs. The highest SSS was observed in one axial VAD, and the longest exposure time was observed in 1 centrifugal VAD. These 2 VADs generated the highest HI. The shear-induced HI varied as a function of flow rate within each cardiac cycle. At fixed pump speed, the HI was greatest at low flow rate due to longer exposure time to shear stress compared with at high flow rate. Subsequently, we hypothesize that to reduce the risk of blood trauma during VAD support, shear stress magnitude and exposure time need to be minimized. Copyright © 2017 John Wiley & Sons, Ltd.

  4. The Effect of Lipemia on Peripheral Blood Flow

    Science.gov (United States)

    Zsotér, Thomas; Fam, Wadie M.; McGregor, Maurice

    1964-01-01

    The effect of lipemia on peripheral blood flow was studied in patients with and without peripheral vascular disease. Blood flow was measured by venous occlusion plethysmography in the calf and/or finger four to six hours after a fatty meal and after intravenous heparin. The abolition of postprandial lipemia by heparin was determined by measuring the plasma lactescence. Heparin resulted in no change in finger flow of either group or in calf flow in the control group. In nine out of 10 patients with occlusive vascular disease of the legs, it resulted in a small but significant increase of calf blood flow. No such alteration was found when heparin was given following a non-fatty meal. In 12 patients with intermittent claudication the clearing of postprandial lipemia by heparin caused prolongation of claudication time, as measured by the appearance of pain on treadmill exercise. It is concluded that, in some cases, postprandial lipemia is associated with a decrease in blood flow in a limb which is already the site of occlusive vascular disease. PMID:14146862

  5. Alterations in Cerebral Blood Flow after Resuscitation from Cardiac Arrest

    Directory of Open Access Journals (Sweden)

    Bistra Iordanova

    2017-08-01

    Full Text Available Greater than 50% of patients successfully resuscitated from cardiac arrest have evidence of neurological disability. Numerous studies in children and adults, as well as in animal models have demonstrated that cerebral blood flow (CBF is impaired after cardiac arrest. Stages of cerebral perfusion post-resuscitation include early hyperemia, followed by hypoperfusion, and finally either resolution of normal blood flow or protracted hyperemia. At the level of the microcirculation the blood flow is heterogeneous, with areas of no flow, low flow, and increased flow. CBF directed therapies in animal models of cardiac arrest improved neurological outcome, and therefore, the alterations in CBF after cardiac arrest likely contribute to the development of hypoxic ischemic encephalopathy. Current intensive care after cardiac arrest is centered upon maintaining systemic oxygenation, normal blood pressure values for age, maintaining general homeostasis, and avoiding hyperthermia. Assessment of CBF and oxygenation is not routinely performed after cardiac arrest. Currently available and underutilized techniques to assess cerebral perfusion include transcranial doppler, near-infrared spectroscopy, and arterial spin labeling magnetic resonance imaging. Limited clinical studies established the role of CBF and oxygenation monitoring in prognostication after cardiac arrest and few studies suggest that guiding critical care post-resuscitation to mean arterial pressures above the minimal autoregulatory range might improve outcome. Important knowledge gaps thus remain in cerebral monitoring and CBF and oxygen goal-directed therapies post-resuscitation from cardiac arrest.

  6. Involvement of calcitonin gene-related peptide in migraine: regional cerebral blood flow and blood flow velocity in migraine patients

    DEFF Research Database (Denmark)

    Lassen, L.H.; Jacobsen, V.B.; Haderslev, P.A.

    2008-01-01

    Calcitonin gene-related peptide (CGRP)-containing nerves are closely associated with cranial blood vessels. CGRP is the most potent vasodilator known in isolated cerebral blood vessels. CGRP can induce migraine attacks, and two selective CGRP receptor antagonists are effective in the treatment...... g/min) or placebo for 20 min was studied in 12 patients with migraine without aura outside attacks. Xenon-133 inhalation SPECT-determined regional cerebral blood flow (rCBF) and transcranial Doppler (TCD)-determined blood velocity (V-mean) in the middle cerebral artery (MCA), as well as the heart...

  7. Estimation of blood flow rates in large microvascular networks.

    Science.gov (United States)

    Fry, Brendan C; Lee, Jack; Smith, Nicolas P; Secomb, Timothy W

    2012-08-01

    Recent methods for imaging microvascular structures provide geometrical data on networks containing thousands of segments. Prediction of functional properties, such as solute transport, requires information on blood flow rates also, but experimental measurement of many individual flows is difficult. Here, a method is presented for estimating flow rates in a microvascular network based on incomplete information on the flows in the boundary segments that feed and drain the network. With incomplete boundary data, the equations governing blood flow form an underdetermined linear system. An algorithm was developed that uses independent information about the distribution of wall shear stresses and pressures in microvessels to resolve this indeterminacy, by minimizing the deviation of pressures and wall shear stresses from target values. The algorithm was tested using previously obtained experimental flow data from four microvascular networks in the rat mesentery. With two or three prescribed boundary conditions, predicted flows showed relatively small errors in most segments and fewer than 10% incorrect flow directions on average. The proposed method can be used to estimate flow rates in microvascular networks, based on incomplete boundary data, and provides a basis for deducing functional properties of microvessel networks. © 2012 John Wiley & Sons Ltd.

  8. Intraoperative multi-exposure speckle imaging of cerebral blood flow.

    Science.gov (United States)

    Richards, Lisa M; Kazmi, Sm Shams; Olin, Katherine E; Waldron, James S; Fox, Douglas J; Dunn, Andrew K

    2017-09-01

    Multiple studies have demonstrated that laser speckle contrast imaging (LSCI) has high potential to be a valuable cerebral blood flow monitoring technique during neurosurgery. However, the quantitative accuracy and sensitivity of LSCI is limited, and highly dependent on the exposure time. An extension to LSCI called multi-exposure speckle imaging (MESI) overcomes these limitations, and was evaluated intraoperatively in patients undergoing brain tumor resection. This clinical study ( n = 8) recorded multiple exposure times from the same cortical tissue area spanning 0.5-20 ms, and evaluated images individually as single-exposure LSCI and jointly using the MESI model. This study demonstrated that the MESI estimates provided the broadest flow sensitivity for sampling the flow magnitude in the human brain, closely followed by the shorter exposure times. Conservation of flow analysis on vascular bifurcations was used to validate physiological accuracy, with highly conserved flow estimates (goodness-of-fit with proper image calibration and acquisition, and was used to monitor blood flow changes after tissue cautery. Results from this study demonstrate that intraoperative MESI can be performed with high quantitative accuracy and sensitivity for cerebral blood flow monitoring.

  9. Erythrocyte volume in acidified venous blood from exercising limbs.

    Science.gov (United States)

    Van Beaumont, W.; Rochelle, R. H.

    1973-01-01

    Five male volunteers performed arm exercises in the sitting position by cranking the pedals of a bicycle ergometer at 50 revolutions per min. The initial mechanical work load of 0 kgm/min was increased every minute by 75 kgm/min until exhaustion occurred. The data obtained show a significant acidification of the venous blood from the working arms and a substantial increase in venous pCO2 during this type of muscular activity. However, the erythrocyte volume remained unaltered during the exercise.

  10. A dynamic model of renal blood flow autoregulation

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Marsh, D J

    1994-01-01

    To test whether a mathematical model combining dynamic models of the tubuloglomerular feedback (TGF) mechanism and the myogenic mechanism was sufficient to explain dynamic autoregulation of renal blood flow, we compared model simulations with experimental data. To assess the dynamic characteristics...... of renal autoregulation, a broad band perturbation of the arterial pressure was employed in both the simulations and the experiments. Renal blood flow and tubular pressure were used as response variables in the comparison. To better approximate the situation in vivo where a large number of individual...... data, which shows a unimodal curve for the admittance phase. The ability of the model to reproduce the experimental data supports the hypothesis that dynamic autoregulation of renal blood flow is due to the combined action of TGF and the myogenic response....

  11. Mediators of increased blood flow in porcine skin

    Directory of Open Access Journals (Sweden)

    H. D. Moore

    1992-01-01

    Full Text Available Nicotinates and benzalkonium chloride (B.Cl cause inflammatory changes in human skin, thought to be dependent upon prostaglandin formation. This study has examined the effects of hexyl-nicotinate (HN and B.Cl on blood flow in porcine skin. The role of prostaglandins and interleukin (IL-1 in the blood flow response has been investigated. Blood flow was increased by both HN and B.Cl, the response to B.Cl being more protracted. Cyclooxygenase inhibitor pretreatment reduced these responses. IL-1-like biological activity was identified in normal porcine epidermis and the amounts recovered from inflamed skin were similar. Thus prostaglandin formation in HN or B.Cl-induced inflammation, if IL-1 dependent, is not associated with the loss of significant amounts of the cytokine from the epidermis.

  12. Reduced blood flow to contracting skeletal muscle in ageing humans

    DEFF Research Database (Denmark)

    Nyberg, Michael Permin; Hellsten, Ylva

    2016-01-01

    consequences of ageing and physical inactivity can be challenging; yet, observations from cross-sectional and longitudinal studies on the effects of physical activity have provided some insight. Physical activity has the potential to offset the age-related decline in blood flow to contracting skeletal muscle...... the O2 demand of the active skeletal muscle of aged individuals during conditions where systemic blood flow is not limited by cardiac output seems to a large extent to be related to the level of physical activity. This article is protected by copyright. All rights reserved.......The ability to sustain a given absolute submaximal workload declines with advancing age likely due to a lower level of blood flow and O2 delivery to the exercising muscles. Given that physical inactivity mimics many of the physiological changes associated with ageing, separating the physiological...

  13. [Effect of physical exercise on aortic blood flow in patients with primary arterial hypertension].

    Science.gov (United States)

    Trojnar, R; Rymar, B; Wysokiński, A; Markiewicz, M; Lakomski, B

    1992-08-01

    In 40 patients (30 men and 10 women) aged to 21 to 48 years (mean 42 years) with essential hypertension stage II, according to WHO classification, blood flow was recorder in the ascending aorta by Doppler echocardiography. The investigation was done in erect position, at rest, and during 30 seconds of each phase of exercise on moving track. The control group comprised 20 healthy males aged 23-45 years (mean 38 years). In essential hypertension the values of the heart rate (T), maximal (MAX-V) and mean (ME-V) flow velocity, and systolic volume index (SVI) were significantly higher at rest than in controls. In the 3rd minute of exercise the values of heart rate (T), mean flow acceleration (ACC) and minute volume index (COI) were significantly higher in the patients than in controls. At the peak exercise MAX-V, ME-V and COI were significantly lower than in controls. On the other hand, in the 5th minute after the exercise the values of all the analysed blood flow parametres in the aorta were significantly higher in the patients. After the exercise the fall of the integral flow (INTG) and SVI greater in controls than in patients, while the rise of the mean flow acceleration (ACC) was higher in hypertension than in health.

  14. Blood flow in ductus venosus in early uncomplicated pregnancy.

    Science.gov (United States)

    Sodowski, Krzysztof; Cnota, Wojciech; Czuba, Bartosz; Borowski, Dariusz; Wielgos, Miroslaw; Kaminski, Pawel; Jaczyńska, Renata; Włoch, Agata; Kuka, Dorota; Zwirska-Korczala, Krystyna; Szaflik, Krzysztof

    2007-10-01

    The ductus venosus is the very important part of fetal venous circulation. It plays a central role in return of venous blood from the placenta. This unique shunt carries well-oxygenated blood from the umbilical vein through the inferior atrial inlet on its way across the foramen ovale. Using Doppler ultrasound, it is possible to assess the blood flow in fetal vessels including ductus venosus. It is observed, in animal and human studies, that the typical waveform for blood flow in ductus venosus in early pregnancy can be different depending on numerous conditions e.g. fetal karyotype. This study is performed to assess the physiologic parameters of blood flow in ductus venosus in uncomplicated early pregnancy. 404 women were examined between 11+0 and 13+6 weeks (+ days) of gestation by ultrasound. Fetal crown-rump length (CRL) was measured to assess the gestational age. The assessment of risk of fetal abnormalities was based on nuchal translucency (NT) measurement. The ductus venosus blood flow with color and spectral Doppler was obtained in all patients. The following features were assessed: pulsatility index (PI), and direction of flow (positive/negative) during atrial contraction (wave A). All cases were followed up to 22 weeks of gestation when the control scan was performed. 30 cases were excluded from the uncomplicated group due to: high risk of fetal abnormalities, fetal loss, confirmed fetal abnormalities and utero-placental pathology. 374 women were considered as uncomplicated pregnancy. In both uncomplicated and complicated groups the mean values for pulsatility index (PI) were established. The mean PI value in uncomplicated pregnancies was: 0.91 (SD +/- 0.32). No significant differences between groups were noticed. In 370 cases of uncomplicated pregnancy the A wave direction was positive but in 1.1% of cases the reverse flow in atrial contraction was observed.

  15. determination of volume and direction of flow of kainji reservoir ...

    African Journals Online (AJOL)

    HOD

    Determination of volume and direction of flow of river plays a key role in determining the direction of transported materials to the downstream. Bathymetry survey which incorporate sounding to determine the depths with respect to a known bench mark together with coordinates of points referenced to a minimum of two ...

  16. Quantification of regional blood flow to canine flexor tendons

    Energy Technology Data Exchange (ETDEWEB)

    Weidman, K.A.; Simonet, W.T.; Wood, M.B.; Cooney, W.P.; Ilstrup, D.M.

    1984-01-01

    Although the blood supply and the microcirculation of flexor tendons have been studied and defined extensively using qualitative methods, the quantitative assessment of blood flow has been lacking because of the limitations of the available experimental techniques. The authors studied the regional blood supply to the flexor tendons of dogs by the technique of radionuclide-labeled microspheres. Seven adult mongrel dogs were used. Microsphere injection and tissue-counting techniques previously used for other tissues were applied. Samples of proximal, isthmus, and distal portions of the profundus and superficialis flexor tendons were harvested from each digital unit of available limbs from each dog. Mean (+/- SE) flows (ml/100 g dry tissue/min) were proximal profundus 1.78 +/- 0.60 and superficialis 7.10 +/- 1.50. The differences were significant. The study suggests that regional variation in blood flow to canine digital flexor tendons exists, so that a single value for blood flow to these tendons is not relevant. Furthermore, the study supports the concept of dual (vascular and synovial) nutrition to the digital flexor tendons in dogs. These observations may have implications regarding tendon repair techniques.

  17. Quantification of regional blood flow to canine flexor tendons.

    Science.gov (United States)

    Weidman, K A; Simonet, W T; Wood, M B; Cooney, W P; Ilstrup, D M

    1984-01-01

    Although the blood supply and the microcirculation of flexor tendons have been studied and defined extensively using qualitative methods, the quantitative assessment of blood flow has been lacking because of the limitations of the available experimental techniques. We studied the regional blood supply to the flexor tendons of dogs by the technique of radionuclide-labeled microspheres. Seven adult mongrel dogs were used. Microsphere injection and tissue-counting techniques previously used for other tissues were applied. Samples of proximal, isthmus, and distal portions of the profundus and superficialis flexor tendons were harvested from each digital unit of available limbs from each dog. Mean (+/- SE) flows (ml/100 g dry tissue/min) were proximal profundus 1.78 +/- 0.60 and superficialis 7.10 +/- 1.50. The differences were significant (p less than 0.01). The study suggests that regional variation in blood flow to canine digital flexor tendons exists, so that a single value for blood flow to these tendons is not relevant. Furthermore, the study supports the concept of dual (vascular and synovial) nutrition to the digital flexor tendons in dogs. These observations may have implications regarding tendon repair techniques.

  18. Understanding particle margination in blood flow - A step toward optimized drug delivery systems.

    Science.gov (United States)

    Müller, Kathrin; Fedosov, Dmitry A; Gompper, Gerhard

    2016-01-01

    Targeted delivery of drugs and imaging agents is very promising to develop new strategies for the treatment of various diseases such as cancer. For an efficient targeted adhesion, the particles have to migrate toward the walls in blood flow - a process referred to as margination. Due to a huge diversity of available carriers, a good understanding of their margination properties in blood flow depending on various flow conditions and particle properties is required. We employ a particle-based mesoscopic hydrodynamic simulation approach to investigate the margination of different carriers for a wide range of hematocrits (volume fraction of red blood cells) and flow rates. Our results show that margination strongly depends on the thickness of the available free space close to the wall, the so-called red blood cell-free layer (RBC-FL), in comparison to the carrier size. The carriers with a few micrometers in size are comparable with the RBC-FL thickness and marginate better than their sub-micrometer counterparts. Deformable carriers, in general, show worse margination properties than rigid particles. Particle margination is also found to be most pronounced in small channels with a characteristic size comparable to blood capillaries. Finally, different margination mechanisms are discussed. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Blood flow and microdialysis in the human femoral head

    DEFF Research Database (Denmark)

    Bøgehøj, Morten; Emmeluth, Claus; Overgaard, Søren

    2007-01-01

    ischemia and measure changes in blood flow. MATERIAL AND METHODS: In 9 patients undergoing total hip arthroplasty for primary osteoarthrosis, two MD catheters were inserted into the femoral head through two drill holes after the blood flow had been visualized by LD. Then primary samples were collected...... with the femoral head in situ; thereafter, the head was removed and samples were collected over the following 4 hours ex vivo. The variables obtained by MD were concentrations of glucose, lactate, pyruvate, and glycerol in extracellular fluid. RESULTS: The results showed development of ischemia...

  20. Endoscopic retrograde cholangiopancreatography causes reduced myocardial blood flow

    DEFF Research Database (Denmark)

    Christensen, M; Hendel, H W; Rasmussen, V

    2002-01-01

    BACKGROUND AND STUDY AIMS: Previous studies have shown that up to 50% of healthy patients may develop ST-segment changes during upper gastrointestinal endoscopy. The aim of the study was to evaluate myocardial blood flow in patients during endoscopic retrograde cholangiopancreatography (ERCP...... with either of the two methods, while two patients developed signs of ischemia during ERCP with both the Holter tape recording and on myocardial scintigraphy (P = 0.02). CONCLUSIONS: Patients undergoing ERCP may develop true myocardial ischemia with reduced myocardial blood flow. Although this is a small...

  1. 1-D blood flow modelling in a running human body.

    Science.gov (United States)

    Szabó, Viktor; Halász, Gábor

    2017-07-01

    In this paper an attempt was made to simulate blood flow in a mobile human arterial network, specifically, in a running human subject. In order to simulate the effect of motion, a previously published immobile 1-D model was modified by including an inertial force term into the momentum equation. To calculate inertial force, gait analysis was performed at different levels of speed. Our results show that motion has a significant effect on the amplitudes of the blood pressure and flow rate but the average values are not effected significantly.

  2. Nocturnal foot blood flow in patients with arterial insufficiency

    DEFF Research Database (Denmark)

    Jelnes, Rolf; Tønnesen, K H

    1984-01-01

    Twenty-four hour continuous recording of xenon (133Xe) wash-out from the forefoot was performed on patients with normal circulations (n = 10) and on patients with different degrees of arterial insufficiency (n = 36). During day hours the calculated subcutaneous blood flow in the forefoot...... was on average the same in patients with normal circulations and in patients with different degrees of arterial insufficiency (mean: 2.0 +/- 0.8 ml min-1 100 g-1). During sleep the blood flow nearly doubled in patients with normal circulations; no systematic change was seen in patients with intermittent...

  3. Disparity in regional cerebral blood flow during electrically induced seizure

    DEFF Research Database (Denmark)

    Sestoft, D; Meden, P; Hemmingsen, R

    1993-01-01

    This is a presentation of 2 cases in which the intraictal regional cerebral blood flow distribution was measured with the 99mTc-HMPAO single photon emission computerized tomography technique during an electrically induced seizure. Although the seizure was verified as generalized on electroencepha......This is a presentation of 2 cases in which the intraictal regional cerebral blood flow distribution was measured with the 99mTc-HMPAO single photon emission computerized tomography technique during an electrically induced seizure. Although the seizure was verified as generalized...

  4. The effect of hyperosmotic solutions on the hepatic blood flow

    DEFF Research Database (Denmark)

    Winkler, K; Henriksen, Jens Henrik; Tygstrup, N

    1993-01-01

    infusions of hyperosmotic galactose (50%, 84-100 ml) and mannitol (25%, 100 ml), with physiological saline (100 ml) as control. Portal blood flow increased to a peak value of (39% [P = 0.06] galactose and 37%, [P = 0.06], mannitol) soon after stop of the hyperosmotic infusion. For galactose the change ended...... somewhat earlier than for mannitol. Saline induced a minor increase (15%). Similarly, increments of, on average, 144% of the hepatic blood flow rate was seen in six patients with cirrhosis, following infusion of hyperosmotic galactose, the increase being more pronounced than in the pigs. The causes...

  5. The role of macronutrients in gastrointestinal blood flow.

    Science.gov (United States)

    de Aguilar-Nascimento, José Eduardo

    2005-09-01

    The presence of luminal nutrients after a meal increases gastrointestinal blood flow in a phenomenon called postprandial hyperemia. In many conditions related to splanchnic hypoperfusion, enteral nutrition may play a role in counterbalancing the installed splanchnic low-flow state by producing intestinal hyperemia. However, when the gut is hypoperfused there is a chance of enteral nutrition producing a mismatch of the oxygen demand: supply ratio with subsequence gut ischemia. This article aims to review the effects of macronutrients on gastrointestinal blood flow in both health and critical conditions, especially those related to hepatosplanchnic hypoperfusion. Splanchnic blood flow is related not only to the route (intravenous or enteral) and timing of nutritional support (during the course of the insult) but also to the composition of the formula. Critically ill patients with gut hypoperfusion may tolerate enteral nutrition, but this effect may be restricted to the early post-injury phase. During ischaemia reperfusion injury, immune nutrients may promote different outcomes: glutamine may protect whereas arginine may deteriorate the mucosal barrier and enhance permeability. Understanding the relationship between macronutrients and gastrointestinal blood flow is a major challenge. Ongoing research in nutritional support in hypoperfused, catecholamine-dependent patients will open the door to optimize the recovery of patients in critical care.

  6. Implementing a routine flow cytometry assay for nucleated red blood cell counts in cord blood units.

    Science.gov (United States)

    Simard, C; Cloutier, M; Jobin, C; Dion, J; Fournier, D; Néron, S

    2016-12-01

    As required by standards organizations, Héma-Québec Cord Blood Bank performs enumeration of nucleated red blood cells (NRBCs) in cord blood units (CBUs). This study presents the validation and implementation approaches developed to transfer the routine NRBC enumeration from the manual blood film method to a flow cytometric assay. The flow cytometry method was adapted from Tsuji (Cytometry, 37, 1999, 291). This assay was validated to assess the specificity, detection limit, repeatability, and reproducibility of the method, including interoperator and interlaboratory testing. Finally, postimplementation follow-up and adjustments were performed for CBU over a 7-month period. Blood film and flow cytometry NRBC enumerations showed a strong correlation (n = 40; Pearson's r correlation = 0.90). Validation was successful as exemplified by the correlation in interlaboratory testing (n = 30; r = 0.98). During implementation, our routine laboratory analyses revealed that CBU with low NRBC content (≤2%), representing 26% of all CBU tested, resulted in 15% of repeated reading and/or staining and was the principal source of nonconformity. Small adjustments in the standard operating procedures (SOPs), including a fixed 200-event setting in the NRBC gate for the second reading of the replicates, have completely solved this issue. Flow cytometric NRBC enumerations, now implemented in Héma-Québec Public Cord Blood Bank, is an improvement in the efficiency of our operations by integrating the count for NRBC into our flow cytometry platform. © 2016 John Wiley & Sons Ltd.

  7. Is oligohydramnios in postterm pregnancy associated with redistribution of fetal blood flow?

    Science.gov (United States)

    Bar-Hava, I; Divon, M Y; Sardo, M; Barnhard, Y

    1995-08-01

    Our purpose was to determine whether postterm patients with oligohydramnios differ in their fetal and umbilical blood flow distribution from those with a normal volume of amniotic fluid. Pulsed-wave Doppler imaging was used prospectively to determine the resistance index in the fetal middle cerebral, renal, and umbilical arteries in 57 postterm (i.e., > 41 weeks' gestation) pregnancies. Semiquantitative assessment of amniotic fluid volume was obtained by use of the ultrasonographically determined amniotic fluid index. Oligohydramnios (amniotic fluid index postterm patients, suggesting that the cause of oligohydramnios in these patients is related to birth weight rather than to renal perfusion.

  8. Mathematical Modelling of Blood Flow through a Tapered Overlapping Stenosed Artery with Variable Viscosity

    Directory of Open Access Journals (Sweden)

    G. C. Shit

    2014-01-01

    Full Text Available This paper presents a theoretical study of blood flow through a tapered and overlapping stenosed artery under the action of an externally applied magnetic field. The fluid (blood medium is assumed to be porous in nature. The variable viscosity of blood depending on hematocrit (percentage volume of erythrocytes is taken into account in order to improve resemblance to the real situation. The governing equation for laminar, incompressible and Newtonian fluid subject to the boundary conditions is solved by using a well known Frobenius method. The analytical expressions for velocity component, volumetric flow rate, wall shear stress and pressure gradient are obtained. The numerical values are extracted from these analytical expressions and are presented graphically. It is observed that the influence of hematocrit, magnetic field and the shape of artery have important impact on the velocity profile, pressure gradient and wall shear stress. Moreover, the effect of primary stenosis on the secondary one has been significantly observed.

  9. Blood Pump Development Using Rocket Engine Flow Simulation Technology

    Science.gov (United States)

    Kiris, Cetin C.; Kwak, Dochan

    2002-01-01

    This viewgraph presentation provides information on the transfer of rocket engine flow simulation technology to work involving the development of blood pumps. Details are offered regarding the design and requirements of mechanical heart assist devices, or VADs (ventricular assist device). There are various computational fluid dynamics issues involved in the visualization of flow in such devices, and these are highlighted and compared to those of rocket turbopumps.

  10. Control volume based modelling of compressible flow in reciprocating machines

    DEFF Research Database (Denmark)

    Andersen, Stig Kildegård; Thomsen, Per Grove; Carlsen, Henrik

    2004-01-01

    An approach to modelling unsteady compressible flow that is primarily one dimensional is presented. The approach was developed for creating distributed models of machines with reciprocating pistons but it is not limited to this application. The approach is based on the integral form of the unsteady...... conservation laws for mass, energy, and momentum applied to a staggered mesh consisting of two overlapping strings of control volumes. Loss mechanisms can be included directly in the governing equations of models by including them as terms in the conservation laws. Heat transfer, flow friction......, and multidimensional effects must be calculated using empirical correlations; correlations for steady state flow can be used as an approximation. A transformation that assumes ideal gas is presented for transforming equations for masses and energies in control volumes into the corresponding pressures and temperatures...

  11. Altitude Acclimatization and Blood Volume: Effects of Exogenous Erythrocyte Volume Expansion

    National Research Council Canada - National Science Library

    Sawka, M

    1996-01-01

    ...: (a) altitude acclimatization effects on erythrocyte volume and plasma volume; (b) if exogenous erythrocyte volume expansion alters subsequent erythrocyte volume and plasma volume adaptations; (c...

  12. Nocturnal variations in peripheral blood flow, systemic blood pressure, and heart rate in humans

    DEFF Research Database (Denmark)

    Sindrup, J H; Kastrup, J; Christensen, H

    1991-01-01

    Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage uni.......0001). The synchronism of the nocturnal subcutaneous hyperemia and the decrease in systemic mean arterial blood pressure point to a common, possibly central nervous or humoral, eliciting mechanism.......Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage unit...

  13. Caval blood flow distribution in patients with Fontan circulation: quantification by using particle traces from 4D flow MR imaging.

    Science.gov (United States)

    Bächler, Pablo; Valverde, Israel; Pinochet, Natalia; Nordmeyer, Sarah; Kuehne, Titus; Crelier, Gérard; Tejos, Cristián; Irarrazaval, Pablo; Beerbaum, Philipp; Uribe, Sergio

    2013-04-01

    To validate the use of particle traces derived from four-dimensional (4D) flow magnetic resonance (MR) imaging to quantify in vivo the caval flow contribution to the pulmonary arteries (PAs) in patients who had been treated with the Fontan procedure. The institutional review boards approved this study, and informed consent was obtained. Twelve healthy volunteers and 10 patients with Fontan circulation were evaluated. The particle trace method consists of creating a region of interest (ROI) on a blood vessel, which is used to emit particles with a temporal resolution of approximately 40 msec. The flow distribution, as a percentage, is then estimated by counting the particles arriving to different ROIs. To validate this method, two independent observers used particle traces to calculate the flow contribution of the PA to its branches in volunteers and compared it with the contribution estimated by measuring net forward flow volume (reference method). After the method was validated, caval flow contributions were quantified in patients. Statistical analysis was performed with nonparametric tests and Bland-Altman plots. P < .05 was considered to indicate a significant difference. Estimation of flow contributions by using particle traces was equivalent to estimation by using the reference method. Mean flow contribution of the PA to the right PA in volunteers was 54% ± 3 (standard deviation) with the reference method versus 54% ± 3 with the particle trace method for observer 1 (P = .4) and 54% ± 4 versus 54% ± 4 for observer 2 (P = .6). In patients with Fontan circulation, 87% ± 13 of the superior vena cava blood flowed to the right PA (range, 63%-100%), whereas 55% ± 19 of the inferior vena cava blood flowed to the left PA (range, 22%-82%). Particle traces derived from 4D flow MR imaging enable in vivo quantification of the caval flow distribution to the PAs in patients with Fontan circulation. This method might allow the identification of patients at risk of

  14. Blood flow analysis with considering nanofluid effects in vertical channel

    Science.gov (United States)

    Noreen, S.; Rashidi, M. M.; Qasim, M.

    2017-06-01

    Manipulation of heat convection of copper particles in blood has been considered peristaltically. Two-phase flow model is used in a channel with insulating walls. Flow analysis has been approved by assuming small Reynold number and infinite length of wave. Coupled equations are solved. Numerical solution are computed for the pressure gradient, axial velocity function and temperature. Influence of attention-grabbing parameters on flow entities has been analyzed. This study can be considered as mathematical representation to the vibrance of physiological systems/tissues/organs provided with medicine.

  15. Chaotic Dynamics of Red Blood Cells in a Sinusoidal Flow

    Science.gov (United States)

    Dupire, Jules; Abkarian, Manouk; Viallat, Annie

    2010-04-01

    We show that the motion of individual red blood cells in an oscillating moderate shear flow is described by a nonlinear system of three coupled oscillators. Our experiments reveal that the cell tank treads and tumbles either in a stable way with synchronized cell inclination, membrane rotation and hydrodynamic oscillations, or in an irregular way, very sensitively to initial conditions. By adapting our model described previously, we determine the theoretical diagram for the red cell motion in a sinusoidal flow close to physiological shear stresses and flow variation frequencies and reveal large domains of chaotic motions. Finally, fitting our observations allows a characterization of cell viscosity and membrane elasticity.

  16. Single-step preparation and image-based counting of minute volumes of human blood.

    Science.gov (United States)

    Smith, Zachary J; Gao, Tingjuan; Chu, Kaiqin; Lane, Stephen M; Matthews, Dennis L; Dwyre, Denis M; Hood, James; Tatsukawa, Keith; Heifetz, Laurence; Wachsmann-Hogiu, Sebastian

    2014-08-21

    Current flow-based blood counting devices require significant medical infrastructure and are not appropriate for field use. In this article we report on the development of a sample preparation, measurement, and analysis method that permits automated and accurate counting of red blood cells (RBCs), white blood cells (WBCs), and platelets, as well as allowing a 3-part differential of the WBCs to be performed on extremely small volumes of whole blood. This method is compatible with portable instrumentation that can be deployed in the field. The method consists of serially diluting blood samples first with sodium dodecyl sulfate dissolved in phosphate buffered saline, then in acridine orange dissolved in phosphate buffered saline, followed by fluorescence and dark field imaging with low magnification objectives. Image analysis is performed to extract cell counts and differentials. We performed a paired analysis of 20 volunteers with complete blood count values both within and beyond the normal reference range using a commercial automated hematology analyzer and the image-based method, with the new method achieving accuracies comparable to that of the commercial system. Because the sample preparation and imaging are simple and inexpensive to implement, this method has applications for pediatrics, clinician offices, and global health in regions that do not have access to central hematology laboratories.

  17. The history of the microsphere method for measuring blood flows with special reference to myocardial blood flow: a personal memoir.

    Science.gov (United States)

    Hoffman, Julien I E

    2017-04-01

    We use many types of equipment and technologies to make our measurements but give little thought to how they developed. Evolution was once described as a series of recoils from blind alleys, and this is exemplified by the gradual development of the microsphere method of measuring blood flows. The microsphere method is one of the most frequently used methods for measuring blood flow to organs and portions of organs. The method can measure myocardial blood flow with reasonable accuracy (within 10%) down to samples weighing >50 mg but probably will not do so for samples weighing 1-10 mg. Microspheres with diameters from 10 to 15 μm provide the best compromise between accurate flow measurement and retention in tissue. Radioactive labels have been almst entirely replaced by fluorescent labels, but colored microspheres and neutron-activated labels are also used.NEW & NOTEWORTHY The contributions of the various individuals who developed the microsphere method of measuring regional blood flows and how these advances took place are brought to light in this paper. Copyright © 2017 the American Physiological Society.

  18. Pulmonary diffusing capacity, capillary blood volume, and cardiac output during sustained microgravity

    Science.gov (United States)

    Prisk, G. K.; Guy, Harold J. B.; Elliott, Ann R.; Deutschman, Robert A., III; West, John B.

    1993-01-01

    We measured pulmonary diffusing capacity (DL), diffusing capacity per unit lung volume, pulmonary capillary blood volume (Vc), membrane diffusing capacity (Dm), pulmonary capillary blood flow or cardiac output (Qc), and cardiac stroke volume (SV) in four subjects exposed to nine days of microgravity. DL in microgravity was elevated compared with preflight standing values and was higher than preflight supine because of the elevation of both Vc and Dm. The elevation in Vc was comparable to that measured supine in 1 G, but the increase in Dm was in sharp contrast to the supine value. We postulate that, in 0 G, pulmonary capillary blood is evenly distributed throughout the lung, providing for uniform capillary filling, leading to an increase in the surface area available for diffusion. By contrast, in the supine 1-G state, the capillaries are less evenly filled, and although a similar increase in blood volume is observed, the corresponding increase in surface area does not occur. DL and its subdivisions showed no adaptive changes from the first measurement 24 h after the start of 0 G to eight days later. Similarly, there were no trends in the postflight data, suggesting that the principal mechanism of these changes was gravitational. The increase in Dm suggests that subclinical pulmonary edema did not result from exposure to 0 G. Qc was modestly increased inflight and decreased postflight compared with preflight standing. Compared with preflight standing, SV was increased 46 percent inflight and decreased 14 percent in the 1st week postflight. There were temporal changes in Qc and SV during 0 G, with the highest values recorded at the first measurement, 24 h into the flight. The lowest values of Qc and SV occurred on the day of return.

  19. Oscillations and chaos in renal blood flow control

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H

    1993-01-01

    In normotensive, halothane-anesthetized rats, oscillations can be found both in the single-nephron blood flow and in the tubular pressure. Experimental data and computer simulations support the hypothesis that the oscillations are caused by the tubuloglomerular feedback (TGF) mechanism. Model...

  20. Disparity in regional cerebral blood flow during electrically induced seizure

    DEFF Research Database (Denmark)

    Sestoft, D; Meden, P; Hemmingsen, R

    1993-01-01

    This is a presentation of 2 cases in which the intraictal regional cerebral blood flow distribution was measured with the 99mTc-HMPAO single photon emission computerized tomography technique during an electrically induced seizure. Although the seizure was verified as generalized on electroencepha...

  1. Longitudinal Cerebral Blood Flow Changes during Speech in Hereditary Ataxia

    Science.gov (United States)

    Sidtis, John J.; Strother, Stephen C.; Naoum, Ansam; Rottenberg, David A.; Gomez, Christopher

    2010-01-01

    The hereditary ataxias constitute a group of degenerative diseases that progress over years or decades. With principal pathology involving the cerebellum, dysarthria is an early feature of many of the ataxias. Positron emission tomography was used to study regional cerebral blood flow changes during speech production over a 21 month period in a…

  2. Abnormal blood flow in the sublingual microcirculation at high altitude

    NARCIS (Netherlands)

    Martin, Daniel S.; Ince, Can; Goedhart, Peter; Levett, Denny Z. H.; Grocott, Mike P. W.

    2009-01-01

    We report the first direct observations of deranged microcirculatory blood flow at high altitude, using sidestream dark-field imaging. Images of the sublingual microcirculation were obtained from a group of 12 volunteers during a climbing expedition to Cho Oyu (8,201 m) in the Himalayas.

  3. Whole-body vibration dosage alters leg blood flow

    NARCIS (Netherlands)

    Lythgo, Noel; Eser, Prisca; de Groot, Patricia; Galea, Mary

    The effect of whole-body vibration dosage on leg blood flow was investigated. Nine healthy young adult males completed a set of 14 random vibration and non-vibration exercise bouts whilst squatting on a Galileo 900 plate. Six vibration frequencies ranging from 5 to 30 Hz (5 Hz increments) were used

  4. [Assessing resveratrol effect on ocular blood flow in experiment].

    Science.gov (United States)

    Neroev, V V; Kiseleva, T N; Chudin, A V; Shchipanova, A I; Ramazanova, K A

    2016-01-01

    To study the effect of resveratrol on ocular blood flow in vivo in healthy rats and those that underwent retinal ischemia/reperfusion. The experimental study was performed on 40 Wistar rats (40 eyes). For ocular blood flow evaluation, color Doppler imaging (CDI), power Doppler (PD), and pulsed-wave spectral Doppler ultrasonography were performed using the Voluson E8 Expert ultrasonic diagnostic system (GE Healthcare). All rats were given resveratrol per os for 2 months of the study. Retinal ischemia/reperfusion injury was induced by a subconjunctival injection of endothelin-1. The control group included 10 intact animals. Signs of ischemic damage of the anterior and posterior eye segments were less pronounced in rats that were given resveratrol during both pre-ischemic (30 days) and post-ischemic (30 days) periods of follow-up. There was also a statistically significant increase in the peak systolic and end diastolic velocity of blood flow as well as a decrease in the resistive index of retrobulbar arteries in those rats that underwent ischemia/reperfusion as compared to the controls. Long-term resveratrol use (2 months) has proved effective in improving ocular blood flow in a rat model of retinal ischemia/reperfusion injury.

  5. Influence of blood flow on the coagulation cascade

    DEFF Research Database (Denmark)

    The influence of diffusion and convetive flows on the blood coagulation cascade is investigated for a controlled perfusion experiment. We present a cartoon model and reaction schemes for parts of the coagulation cascade with sunsequent set up of a mathematical model in two space dimensions plus one...

  6. Patterns of regional cerebral blood flow in acute stroke

    DEFF Research Database (Denmark)

    Olsen, T S; Skriver, E B

    1981-01-01

    In a consecutive group of 56 stroke patients the regional cerebral blood flow was measured within 84 hours after stroke. A 254 multidetector scintillation camera and the intracarotid Xenon-133 injection method was used to study rCBF. Typical rCBF-patterns are described and compared to the findings...

  7. Determinants of resting cerebral blood flow in sickle cell disease

    NARCIS (Netherlands)

    Bush, Adam M.; Borzage, Matthew T.; Choi, Soyoung; Václavů, Lena; Tamrazi, Benita; Nederveen, Aart J.; Coates, Thomas D.; Wood, John C.

    2016-01-01

    Stroke is common in children with sickle cell disease and results from an imbalance in oxygen supply and demand. Cerebral blood flow (CBF) is increased in patients with sickle cell disease to compensate for their anemia, but adequacy of their oxygen delivery has not been systematically demonstrated.

  8. Does isolated myocardial bridge really interfere with coronary blood flow?

    Directory of Open Access Journals (Sweden)

    Eid M. Daoud

    2013-06-01

    Conclusions: Myocardial bridging must be considered especially in patients at low risk for coronary atherosclerosis but with angina like chest pain or established myocardial ischemia. We suggest that coronary blood flow is decreased in the patients with MB compared with the patients having normal coronary.

  9. Neurophysiological Basis of Cerebral Blood Flow Control: An ...

    African Journals Online (AJOL)

    The book describes the current understanding of cerebral blood flow control. Subjects covered indude the autonomic nervous system, cellular neurophysiology and neurotransmitter systems. There is a good section on ionic channels and ionic pumps, as well as receptors and metaoolism of the central nervous system.

  10. Cerebral blood flow and oxidative metabolism during human endotoxemia

    DEFF Research Database (Denmark)

    Møller, Kirsten; Strauss, Gitte Irene; Qvist, Jesper

    2002-01-01

    and catecholamines was investigated in eight healthy young volunteers. Cerebral blood flow was measured by the Kety-Schmidt technique at baseline (during normocapnia and voluntary hyperventilation for calculation of subject-specific cerebrovascular CO reactivity), and 90 minutes after an intravenous bolus...

  11. Changes in Peak Expiratory Flow Rate, Blood Pressure and Pulse ...

    African Journals Online (AJOL)

    Changes in Peak Expiratory Flow Rate, Blood Pressure and Pulse Rate Following Ingestion of Increased Coffee Concentrations in Healthy Male Adults. ... It further indicates that, mild doses of coffee confer benefits on airflow in the lungs. While higher doses are also beneficial in improving airflow in the airway, such doses ...

  12. Changes in Peak Expiratory Flow Rate, Blood Pressure and Pulse ...

    African Journals Online (AJOL)

    We studied the effect of different concentrations of coffee on peak expiratory flow rate (PEFR), blood pressure and pulse rate in an attempt to determine some physiological effects of coffee intake. 18 apparently healthy adult males, age range 20 to 30 years, were recruited for the study over a three day period. Varying ...

  13. Increased cerebral blood flow in preeclampsia with magnetic resonance imaging

    NARCIS (Netherlands)

    Zeeman, Gerda G.; Hatab, MR; Twickler, DM

    2004-01-01

    Objective: The purpose of this study was to compare third trimester and nonpregnant cerebral blood flow of women with preeclampsia to normotensive control subjects with the use of magnetic resonance imaging techniques. Study design: Nine normotensive pregnant women and 12 untreated women with

  14. Velocity estimation using synthetic aperture imaging [blood flow

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Jensen, Jørgen Arendt

    2001-01-01

    Presented an approach for synthetic aperture blood flow ultrasound imaging. Estimates with a low bias and standard deviation can be obtained with as few as eight emissions. The performance of the new estimator is verified using both simulations and measurements. The results demonstrate that a ful...

  15. A New Technology for Detecting Cerebral Blood Flow

    DEFF Research Database (Denmark)

    Schytz, Henrik W; Guo, Song; Jensen, Lars T

    2012-01-01

    There is a need for real-time non-invasive, continuous monitoring of cerebral blood flow (CBF) during surgery, in intensive care units and clinical research. We investigated a new non-invasive hybrid technology employing ultrasound tagged near infrared spectroscopy (UT-NIRS) that may estimate...

  16. Modeling of internal carotid artery aneurysm and blood flow simulation.

    Science.gov (United States)

    Xu, Bingqiang; Zhong, Hua; Duan, Shaoyin

    2015-01-01

    The rupture of aneurysm is quite common in the clinics, and is hazardous to patients. Its occurrence is considered to be related to the hemodynamic abnormalities. To construct the model of internal carotid artery aneurysm (ICA-A), and have a simulation of blood flow. Based on the CTA data from spiral CT scan, the ICA-A model was constructed, and the types of blood flow, wall shear stress (WSS), Von Mises stress (VMS) and pressure were simulated and calculated. ICA-A model has been built and shape is the same morphology as CT 3D-image. In the whole cardiac cycle, the blood flow of aneurysm body is swirl, its velocity is slower than that of aneurysm neck; the maximum deformation, wall shear stress, pressure and von mises stress of aneurysm wall is at the neck, the minimum is at the top. The highest value appeared at 0.52 s in the cardiac cycle of 0.74 s, the lowest is at 0.21 s. It is effective and practical to construct the model of ICA-A base on CTA data. Blood flow simulation of ICA-A will provide new basis for the study on the occurrence and development of aneurysm.

  17. Effect of labetalol on cerebral blood flow and middle cerebral arterial flow velocity in healthy volunteers

    DEFF Research Database (Denmark)

    Schroeder, T; Schierbeck, Jens; Howardy, P

    1991-01-01

    The effect of labetalol, a combined alpha- and beta-adrenoceptor antagonist, on the cerebral circulation was investigated in 7 normotensive subjects. Cerebral blood flow (CBF) was measured with the intravenous 133Xe method and mean flow velocity (Vmean) in the middle cerebral artery was determined...

  18. Cerebral blood flow links insulin resistance and baroreflex sensitivity.

    Directory of Open Access Journals (Sweden)

    John P Ryan

    Full Text Available Insulin resistance confers risk for diabetes mellitus and associates with a reduced capacity of the arterial baroreflex to regulate blood pressure. Importantly, several brain regions that comprise the central autonomic network, which controls the baroreflex, are also sensitive to the neuromodulatory effects of insulin. However, it is unknown whether peripheral insulin resistance relates to activity within central autonomic network regions, which may in turn relate to reduced baroreflex regulation. Accordingly, we tested whether resting cerebral blood flow within central autonomic regions statistically mediated the relationship between insulin resistance and an indirect indicator of baroreflex regulation; namely, baroreflex sensitivity. Subjects were 92 community-dwelling adults free of confounding medical illnesses (48 men, 30-50 years old who completed protocols to assess fasting insulin and glucose levels, resting baroreflex sensitivity, and resting cerebral blood flow. Baroreflex sensitivity was quantified by measuring the magnitude of spontaneous and sequential associations between beat-by-beat systolic blood pressure and heart rate changes. Individuals with greater insulin resistance, as measured by the homeostatic model assessment, exhibited reduced baroreflex sensitivity (b = -0.16, p < .05. Moreover, the relationship between insulin resistance and baroreflex sensitivity was statistically mediated by cerebral blood flow in central autonomic regions, including the insula and cingulate cortex (mediation coefficients < -0.06, p-values < .01. Activity within the central autonomic network may link insulin resistance to reduced baroreflex sensitivity. Our observations may help to characterize the neural pathways by which insulin resistance, and possibly diabetes mellitus, relates to adverse cardiovascular outcomes.

  19. Ultrasonic Doppler blood flow meter for extracorporeal circulation

    Science.gov (United States)

    Dantas, Ricardo G.; Costa, Eduardo T.; Maia, Joaquim M.; Nantes Button, Vera L. d. S.

    2000-04-01

    In cardiac surgeries it is frequently necessary to carry out interventions in internal heart structures, and where the blood circulation and oxygenation are made by artificial ways, out of the patient's body, in a procedure known as extracorporeal circulation (EC). During this procedure, one of the most important parameters, and that demands constant monitoring, is the blood flow. In this work, an ultrasonic pulsed Doppler blood flowmeter, to be used in an extracorporeal circulation system, was developed. It was used a 2 MHz ultrasonic transducer, measuring flows from 0 to 5 liters/min, coupled externally to the EC arterial line destined to adults perfusion (diameter of 9.53 mm). The experimental results using the developed flowmeter indicated a maximum deviation of 3.5% of full scale, while the blood flow estimator based in the rotation speed of the peristaltic pump presented deviations greater than 20% of full scale. This ultrasonic flowmeter supplies the results in a continuous and trustworthy way, and it does not present the limitations found in those flowmeters based in other transduction methods. Moreover, due to the fact of not being in contact with the blood, it is not disposable and it does not need sterilization, reducing operational costs and facilitating its use.

  20. Coded ultrasound for blood flow estimation using subband processing

    DEFF Research Database (Denmark)

    Gran, Fredrik; Udesen, Jesper; Nielsen, Michael bachmann

    2007-01-01

    This paper further investigates the use of coded excitation for blood flow estimation in medical ultrasound. Traditional autocorrelation estimators use narrow-band excitation signals to provide sufficient signal-to-noise-ratio (SNR) and velocity estimation performance. In this paper, broadband...... the excitation signal is broadband and has good spatial resolution after pulse compression. Two different codin-schemes are used in this paper, Barker codes and Golay codes. The performance of the codes for velocity estimation is compared to a conventional approach transmitting a narrow-band pulse. The study...... was carried out using an experimental ultrasound scanner and a commercial linear array 7 MHz transducer. A circulating flow rig was scanned with a beam-to-flow angle of 60 degrees. The flow in the rig was laminar and had a parabolic flow-profile with a peak velocity of 0.09 m/s. The mean relative standard...

  1. Vector flow imaging techniques: An innovative ultrasonographic technique for the study of blood flow.

    Science.gov (United States)

    Goddi, Alfredo; Fanizza, Marianna; Bortolotto, Chandra; Raciti, Maria Vittoria; Fiorina, Ilaria; He, Xujin; Du, Yigang; Calliada, Fabrizio

    2017-11-12

    Doppler ultrasonography is routinely used to identify abnormal blood flow. Nevertheless, conventional Doppler can be used to determine only the axial component of blood flow velocity and is angle dependent. A new method of multidimensional angle-independent estimation of flow velocity, called Vector Flow Imaging (VFI), has been proposed. It quantitatively evaluates the true velocity vector's amplitude and direction at any location into a vessel and displays a more intuitive depiction of the flow movements. High frame rate VFI, based on plane wave imaging, allows a detailed dynamic visualization of complex flow by showing even transient events, otherwise undetectable. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:582-588, 2017. © 2017 Wiley Periodicals, Inc.

  2. Uterine artery blood flow velocity waveforms during uterine contractions.

    Science.gov (United States)

    Li, H; Gudmundsson, S; Olofsson, P

    2003-12-01

    No quantitative or qualitative Doppler velocimetry classification of vascular flow resistance covering all stages of forward and reversed flows exists. The objective of this study was to characterize uterine artery (UtA) flow velocity waveforms (FVWs) obtained during an oxytocin challenge test (OCT) and compare them to FVWs in spontaneous normal labor. Uterine artery Doppler velocimetry was performed during and between uterine contractions in 61 high-risk pregnancies subjected to an OCT and in 20 normal pregnancies undergoing spontaneous labor. FVWs were classified relative to the presence of forward/absent/reversed flow during systole and diastole, and the time-averaged flow velocity over the heart cycle. Eleven different FVW classes were identified. No relationship between FVWs recorded during uterine inertia and contractions was found (P >/= 0.2). In both groups, only forward FVWs were recorded between contractions, whereas during contractions flow reversal was more common in the OCT group (P uterine contractions were not predicted by flow patterns recorded during uterine inertia. Reversal of flow direction was more common during oxytocin-induced uterine contractions than during spontaneous contractions. In cases of predominantly reversed flow, domains of the uterus may be supplied by blood from the contralateral UtA. These observations give new insights into the circulatory dynamics of the uterus during labor, and also point to a possible vasoconstrictory effect in the UtAs of oxytocin at high concentrations. Copyright 2003 ISUOG. Published by John Wiley & Sons, Ltd.

  3. Blood flow in the cerebral venous system: modeling and simulation.

    Science.gov (United States)

    Miraucourt, Olivia; Salmon, Stéphanie; Szopos, Marcela; Thiriet, Marc

    2017-04-01

    The development of a software platform incorporating all aspects, from medical imaging data, through three-dimensional reconstruction and suitable meshing, up to simulation of blood flow in patient-specific geometries, is a crucial challenge in biomedical engineering. In the present study, a fully three-dimensional blood flow simulation is carried out through a complete rigid macrovascular circuit, namely the intracranial venous network, instead of a reduced order simulation and partial vascular network. The biomechanical modeling step is carefully analyzed and leads to the description of the flow governed by the dimensionless Navier-Stokes equations for an incompressible viscous fluid. The equations are then numerically solved with a free finite element software using five meshes of a realistic geometry obtained from medical images to prove the feasibility of the pipeline. Some features of the intracranial venous circuit in the supine position such as asymmetric behavior in merging regions are discussed.

  4. Effects of midazolam on cerebral blood flow in human volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Forster, A.; Juge, O.; Morel, D.

    1982-06-01

    The effects of intravenously administered midazolam on cerebral blood flow were evaluated in eight healthy volunteers using the /sup 133/Xe inhalation technique. Six minutes after an intravenous dose of 0.15 mg/kg midazolam, the cerebral blood flow decreased significantly (P less than 0.001) from a value of 40.6 +/- 3.3 to a value of 27.0 +/- 5.0 ml . 100 g-1 . min-1. Cerebrovascular resistance (CVR) increased from 2.8 +/- 0.2 to 3.9 to 0.6 mmHg/(ml . 100 g-1 . min-1)(P less than 0.001). Mean arterial blood pressure decreased significantly (P less than 0.05) from 117 +/- 8 to 109 +/- 9 mmHg and arterial carbon dioxide tension increased from 33.9 +/- 2.3 to 38.6 +/- 3.2 mmHg (P less than 0.05). Arterial oxygen tension remained stable throughout the study, 484 +/- 95 mmHg before the administration of midazolam and 453 +/- 76 mmHg after. All the subjects slept after the injection of the drug and had anterograde amnesia of 24.5 +/- 5 min. The decrease in mean arterial blood pressure was probably not important since it remained in the physiologic range for cerebral blood flow autoregulation. The increase in arterial carbon dioxide tension observed after the midazolam injection may have partially counteracted the effect of this new benzodiazepine on cerebral blood flow. Our data suggest that midazolam might be a safe agent to use for the induction of anethesia in neurosurgical patients with intracranial hypertension.

  5. A Reconstruction Method of Blood Flow Velocity in Left Ventricle Using Color Flow Ultrasound

    Directory of Open Access Journals (Sweden)

    Jaeseong Jang

    2015-01-01

    Full Text Available Vortex flow imaging is a relatively new medical imaging method for the dynamic visualization of intracardiac blood flow, a potentially useful index of cardiac dysfunction. A reconstruction method is proposed here to quantify the distribution of blood flow velocity fields inside the left ventricle from color flow images compiled from ultrasound measurements. In this paper, a 2D incompressible Navier-Stokes equation with a mass source term is proposed to utilize the measurable color flow ultrasound data in a plane along with the moving boundary condition. The proposed model reflects out-of-plane blood flows on the imaging plane through the mass source term. The boundary conditions to solve the system of equations are derived from the dimensions of the ventricle extracted from 2D echocardiography data. The performance of the proposed method is evaluated numerically using synthetic flow data acquired from simulating left ventricle flows. The numerical simulations show the feasibility and potential usefulness of the proposed method of reconstructing the intracardiac flow fields. Of particular note is the finding that the mass source term in the proposed model improves the reconstruction performance.

  6. [Assessment of maternal cerebral blood flow in patients with preeclampsia].

    Science.gov (United States)

    Mandić, Vesna; Miković, Zeljko; Dukić, Milan; Vasiljević, Mladenko; Filimonović, Dejan; Bogavac, Mirjana

    2005-01-01

    Systemic vasoconstriction in preeclamptic patients increases vascular resistance, and is manifested by increased arterial blood flow velocity. The aim of the study is to evaluate if there is a change of Doppler indices in maternal medial cerbral artery (MCA) in severe preeclampsia due to: 1) severity of clinical symptoms, 2) the begining of eclamptic attack and 3) the application of anticonvulsive therapy. A prospective clinical study included 92 pregnant women, gestational age 28-36 weeks. They were divided into three groups: normotensive (n=30), mild preeclampsia (n=33), and severe preeclampsia (n=29). We investigated maternal cerebral circulation by assessing the MCA. We registrated: pulsatility index (Pi), resistance index (Ri), systolic/diastolic ratio (S/D), and the maximum systolic, end diastolic and medium velocity. Patients with severe preeclampsia were divided into two subgroups. subgroup 1 included patients without symptoms of threatening eclampsia (n=18; 62.06%); while subgroup 2 included those with symptoms of preeclampsia (n=11; 37.94%). All patients with severe preeclampsia were treated with magnesium sulfate (MgSO4), and cerebral blood flow was measured before and after the treatment. Statistical analysis was done by oneway ANOVA, Student t-test and t-paired sample test. The difference was considered to be significant if ppreeclamsia we registrated significantly increased values of all velocities (patients with signs of threatening eclampsia). After MgSO4 treatment in patients with severe preeclampsia significantly decreased values of Pi, Ri, S/D ratio and all velocities were registered. In the studied group of patients with severe preclampsia we found increased velocity values, Pi and Ri, especially in patients with signs of threatened eclampsia, suggesting that blood vessels changes are most prominent in severe preeclampsia. Cerebral blood flow meassurements can be used as a clinical test for the prediction of eclampsia. Magnesium-sulfate (MgSO4

  7. Volumetric lattice Boltzmann simulation for blood flow in aorta arteries

    Science.gov (United States)

    Deep, Debanjan; Yu, Huidan (Whitney); Teague, Shawn

    2012-11-01

    Complicated moving boundaries pose a major challenge in computational fluid dynamics for complex flows, especially in the biomechanics of both blood flow in the cardiovascular system and air flow in the respiratory system where the compliant nature of the vessels can have significant effects on the flow rate and wall shear stress. We develop a computation approach to treat arbitrarily moving boundaries using a volumetric representation of lattice Boltzmann method, which distributes fluid particles inside lattice cells. A volumetric bounce-back procedure is applied in the streaming step while momentum exchange between the fluid and moving solid boundary are accounted for in the collision sub-step. Additional boundary-induced migration is introduced to conserve fluid mass as the boundary moves across fluid cells. The volumetric LBM (VLBM) is used to simulate blood flow in both normal and dilated aorta arteries. We first compare flow structure and pressure distribution in steady state with results from Navier-Stokes based solver and good agreements are achieved. Then we focus on wall stress within the aorta for different heart pumping condition and present quantitative measurement of wall shear and normal stress.

  8. An extracorporeal carbon dioxide removal (ECCO2R) device operating at hemodialysis blood flow rates.

    Science.gov (United States)

    Jeffries, R Garrett; Lund, Laura; Frankowski, Brian; Federspiel, William J

    2017-09-06

    Extracorporeal carbon dioxide removal (ECCO2R) systems have gained clinical appeal as supplemental therapy in the treatment of acute and chronic respiratory injuries with low tidal volume or non-invasive ventilation. We have developed an ultra-low-flow ECCO2R device (ULFED) capable of operating at blood flows comparable to renal hemodialysis (250 mL/min). Comparable operating conditions allow use of minimally invasive dialysis cannulation strategies with potential for direct integration to existing dialysis circuitry. A carbon dioxide (CO2) removal device was fabricated with rotating impellers inside an annular hollow fiber membrane bundle to disrupt blood flow patterns and enhance gas exchange. In vitro gas exchange and hemolysis testing was conducted at hemodialysis blood flows (250 mL/min). In vitro carbon dioxide removal rates up to 75 mL/min were achieved in blood at normocapnia (pCO2 = 45 mmHg). In vitro hemolysis (including cannula and blood pump) was comparable to a Medtronic Minimax oxygenator control loop using a time-of-therapy normalized index of hemolysis (0.19 ± 0.04 g/100 min versus 0.12 ± 0.01 g/100 min, p = 0.169). In vitro performance suggests a new ultra-low-flow extracorporeal CO2 removal device could be utilized for safe and effective CO2 removal at hemodialysis flow rates using simplified and minimally invasive connection strategies.

  9. Radioisotope penile plethysmography: A technique for evaluating corpora cavernosal blood flow during early tumescence

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, A.N.; Graham, M.M.; Ferency, G.F.; Miura, R.S.

    1989-04-01

    Radioisotope penile plethysmography is a nuclear medicine technique which assists in the evaluation of patients with erectile dysfunction. This technique attempts to noninvasively quantitate penile corpora cavernosal blood flow during early penile tumescence using technetium-99m-labeled red blood cells. Penile images and counts were acquired in a steady-state blood-pool phase prior to and after the administration of intracorporal papaverine. Penile counts, images, and time-activity curves were computer analyzed in order to determine peak corporal flow and volume changes. Peak corporal flow rates were compared to arterial integrity (determined by angiography) and venosinusoidal corporal leak (determined by cavernosometry). Peak corporal flow correlated well with arterial integrity (r = 0.91) but did not correlate with venosinusoidal leak parameters (r = 0.01). This report focuses on the methodology and the assumptions which form the foundation of this technique. The strong correlation of peak corporal flow and angiography suggests that radioisotope penile plethysmography could prove useful in the evaluation of arterial inflow disorders in patients with erectile dysfunction.

  10. Blood and plasma treatments: the rationale of high-volume hemofiltration.

    Science.gov (United States)

    Honoré, Patrick M; Joannes-Boyau, Olivier; Gressens, Benjamin

    2007-01-01

    . At this point, the cascade is blocked and this point is called the threshold point. At this level, the cascade is lost and no further harm can be done to the tissue of the organism. Obviously, it is difficult to know when this point has been reached once high-volume hemofiltration is applied. But what is known, is that hemodynamics and survival can be improved in some patients as shown by various studies using high-volume hemofiltration without any significant drop in mediators inside the blood compartment itself. This effect is obtained without a dramatic fall Honoré/Joannes-Boyau/Gressens 388 in the plasma cytokine level because the cytokine or mediator levels should fall at the tissue level and not specifically at the blood compartment level. Nevertheless, the exact mechanism by which high-volume hemofiltration increases the flow of mediators and cytokines between the interstitial compartment and the blood compartment (and back to the blood side) is not known. Before the end of 2005, it was found that this missing step is perhaps well explained by the last theory and/or concept. The third theory and concept is called the mediator delivery hypothesis and has also been called the Alexander concept. In this theory, the use of high-volume hemofiltration and especially high intakes of incoming fluids (3-5 l/h) is able to increase the lymphatic flow 20- to 40-fold, even more so for mediators and cytokine lymphatic flow (drag). This has been demonstrated by several reports and is obviously extremely important. Perhaps this can explain why some very recent studies using high-permeability hemofiltration in sepsis have not been effective in improving hemodynamics and survival in septic acute animal models. In summary various brand new theories will be reviewed here in depth.

  11. Effects of inspiratory flow waveforms on arterial blood gases and respiratory mechanics after open heart surgery.

    Science.gov (United States)

    Polese, G; Lubli, P; Poggi, R; Luzzani, A; Milic-Emili, J; Rossi, A

    1997-12-01

    The clinical usefulness of inspiratory flow pattern manipulation during mechanical ventilation remains unclear. The aim of this study was to investigate the effects of different inspiratory flow waveforms, i.e. constant, sinusoidal and decelerating, on arterial blood gases and respiratory mechanics, in mechanically ventilated patients. Eight patients recovering after open heart surgery for valvular replacement and/or coronary bypass were studied. The ventilator inspiratory flow waveform was changed according to a randomized sequence, keeping constant the other variables of the ventilator settings. We measured arterial blood gases, flow, volume and pressure at the proximal (airway opening pressure (Pao)) and distal (Ptr) ends of the endotracheal tubes before and after 30 min of mechanical ventilation with each inspiratory flow waveform. We computed breathing pattern, respiratory mechanics (pressures and dynamic elastance) and inspiratory work, which was then partitioned into its elastic and resistive components. We found that: 1) arterial oxygen tension (Pa,O2) and arterial carbon dioxide tension (Pa,CO2) were not affected by changes in the inspiratory flow waveform; and 2) peak Pao and Ptr were highest with sinusoidal inspiratory flow, whilst mean Pao and Ptr and total work of breathing were least with constant inspiratory flow, mainly because of a concomitant decrease in resistive work during constant flow inflation. The effects of the inspiratory flow profile on Pao, Ptr and total inspiratory work performed by the ventilator were mainly due to the resistive properties of the endotracheal tubes. We conclude that the ventilator inspiratory flow waveform can influence patients' respiratory mechanics, but has no impact on arterial oxygen and arterial carbon dioxide tension.

  12. Maternal cerebral blood flow during normal pregnancy: a cross-sectional study.

    Science.gov (United States)

    Nevo, Ori; Soustiel, Jean F; Thaler, Israel

    2010-11-01

    Pregnancy is associated with substantial changes in the maternal circulatory physiology. Our aim was to investigate maternal cerebral blood flow (CBF) during normal pregnancies. We prospectively measured maternal CBF in 210 low-risk pregnant women at different gestational ages, and in 15 nonpregnant women. CBF was assessed by measuring blood flow volume in the internal carotid artery (ICA) by dual-beam angle-independent digital Doppler ultrasound. ICA blood flow volume increased during pregnancy from 318 mL/min ± 40.6 mL/min in the first trimester to 382.1 mL/min ± 50.0 mL/min during the third trimester, corresponding to CBF values of 44.4 and 51.8 mL/min(-1)/100 g(-1), respectively (P < .0001). CBF changes were associated with progressive decrease in cerebral vascular resistance and moderate increase in ICA diameter. Maternal CBF is gradually increasing during normal pregnancy. Vasorelaxing impact of estrogens and other factors on cerebral vessels may explain the changes in CBF during pregnancy. Copyright © 2010 Mosby, Inc. All rights reserved.

  13. Ozone Therapy on Cerebral Blood Flow: A Preliminary Report

    Directory of Open Access Journals (Sweden)

    Bernardino Clavo

    2004-01-01

    Full Text Available Ozone therapy is currently being used in the treatment of ischemic disorders, but the underlying mechanisms that result in successful treatment are not well known. This study assesses the effect of ozone therapy on the blood flow in the middle cerebral and common carotid arteries. Seven subjects were recruited for the therapy that was performed by transfusing ozone-enriched autologous blood on 3 alternate days over 1 week. Blood flow quantification in the common carotid artery (n = 14 was performed using color Doppler. Systolic and diastolic velocities in the middle cerebral artery (n = 14 were estimated using transcranial Doppler. Ultrasound assessments were conducted at the following three time points: 1 basal (before ozone therapy, 2 after session #3 and 3 1 week after session #3. The common carotid blood flow had increased by 75% in relation to the baseline after session #3 (P < 0.001 and by 29% 1 week later (P = 0.039. In the middle cerebral artery, the systolic velocity had increased by 22% after session #3 (P = 0.001 and by 15% 1 week later (P = 0.035, whereas the diastolic velocity had increased by 33% after session #3 (P < 0.001 and by 18% 1 week later (P = 0.023. This preliminary Doppler study supports the clinical experience of achieving improvement by using ozone therapy in peripheral ischemic syndromes. Its potential use as a complementary treatment in cerebral low perfusion syndromes merits further clinical evaluation.

  14. Modulation of radial blood flow during Braille character discrimination task.

    Science.gov (United States)

    Murata, Jun; Matsukawa, K; Komine, H; Tsuchimochi, H

    2012-03-01

    Human hands are excellent in performing sensory and motor function. We have hypothesized that blood flow of the hand is dynamically regulated by sympathetic outflow during concentrated finger perception. To identify this hypothesis, we measured radial blood flow (RBF), radial vascular conductance (RVC), heart rate (HR), and arterial blood pressure (AP) during Braille reading performed under the blind condition in nine healthy subjects. The subjects were instructed to read a flat plate with raised letters (Braille reading) for 30 s by the forefinger, and to touch a blank plate as control for the Braille discrimination procedure. HR and AP slightly increased during Braille reading but remained unchanged during the touching of the blank plate. RBF and RVC were reduced during the Braille character discrimination task (decreased by -46% and -49%, respectively). Furthermore, the changes in RBF and RVC were much greater during the Braille character discrimination task than during the touching of the blank plate (decreased by -20% and -20%, respectively). These results have suggested that the distribution of blood flow to the hand is modulated via sympathetic nerve activity during concentrated finger perception.

  15. Ozone Therapy on Cerebral Blood Flow: A Preliminary Report

    Science.gov (United States)

    2004-01-01

    Ozone therapy is currently being used in the treatment of ischemic disorders, but the underlying mechanisms that result in successful treatment are not well known. This study assesses the effect of ozone therapy on the blood flow in the middle cerebral and common carotid arteries. Seven subjects were recruited for the therapy that was performed by transfusing ozone-enriched autologous blood on 3 alternate days over 1 week. Blood flow quantification in the common carotid artery (n = 14) was performed using color Doppler. Systolic and diastolic velocities in the middle cerebral artery (n = 14) were estimated using transcranial Doppler. Ultrasound assessments were conducted at the following three time points: 1) basal (before ozone therapy), 2) after session #3 and 3) 1 week after session #3. The common carotid blood flow had increased by 75% in relation to the baseline after session #3 (P ozone therapy in peripheral ischemic syndromes. Its potential use as a complementary treatment in cerebral low perfusion syndromes merits further clinical evaluation. PMID:15841265

  16. Blood flow and oxygenation in peritendinous tissue and calf muscle during dynamic exercise in humans

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Langberg, H; Green, Sara Marie Ehrenreich

    2000-01-01

    , and (2) whether blood flow is coupled to oxidative metabolism. 2. Seven individuals performed dynamic plantar flexion from 1 to 9 W. Radial artery and popliteal venous blood were sampled for O2, peritendinous blood flow was determined by 133Xe-washout, calf blood flow by plethysmography, cardiac output...

  17. Real-time contrast-enhanced ultrasound determination of microvascular blood volume in abdominal subcutaneous adipose tissue in man. Evidence for adipose tissue capillary recruitment

    DEFF Research Database (Denmark)

    Tobin, L; Simonsen, L; Bülow, J

    2010-01-01

    The adipose tissue metabolism is dependent on its blood perfusion. During lipid mobilization e.g. during exercise and during lipid deposition e.g. postprandial, adipose tissue blood flow is increased. This increase in blood flow may involve capillary recruitment in the tissue. We investigated...... of ultrasound contrast agent to establish the reproducibility of the technique. In nine subjects, the effect of an oral glucose load on blood flow and microvascular volume was measured in abdominal subcutaneous adipose tissue and forearm skeletal muscle. ¹³³Xe washout and venous occlusion strain...... constant. It is concluded that the microvascular volume and changes in volume in abdominal subcutaneous adipose tissue can be assessed using CEU with good reproducibility. Postprandial capillary recruitment takes place in abdominal subcutaneous adipose tissue....

  18. Retrobulbar ocular blood flow changes after phacoemulsification in patients

    Directory of Open Access Journals (Sweden)

    Yin-Ying Zhao

    2016-05-01

    Full Text Available AIM:To evaluate retrobulbar ocular blood flow changes after phacoemulsification.METHODS:Prospective consecutive study. Forty-six eyes from 46 cataract patients scheduled for phacoemulsification surgery at Affiliated Eye Hospital, Wenzhou Medical College were recruited, of which 22 patients with normal blood pressure and 24 patients with hypertension. All eyes were examined by a color Doppler imaging at before, 4h, 1d after surgery. Resistance indexes(RIs, peak systolic flow velocity(PSV, end-diastolic flow velocity(EDVwere assessed in the ophthalmic artery(OA, central retinal artery(CRA, and short posterior ciliary arteries(PCA.RESULTS:RIs of a retrobulbar ocular vessels are stable at 4h and 1d in both group postoperatively. A slight decrease in PSV of PCA in hypertension patients, while a slightly increase in normal patients at 4h postoperatively was observed(10.22±4.39 vs 11.73±4.69. There were no significant difference between them(P=0.089. PSV and EDV in CRA are lower in hypertension patients but without statistical significance compared with normal patients. There was a statistically significant decrease in EDV of the PCA in hypertension patients at 4h postoperatively compared with preoperatively(3.23±1.10 vs 3.63±1.15,P=0.036. CONCLUSION:Retinal blood flow was disturbed at super-early after phacoemulsification. Age and hypertension are important risk factors to phacoemusification.

  19. Narcolepsy: regional cerebral blood flow during sleep and wakefulness

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, F.; Meyer, J.S.; Karacan, I.; Yamaguchi, F.; Yamamoto, M.

    1979-01-01

    Serial measurements of regional cerebral blood flow were made by the 135Xe inhalation method during the early stages of sleep and wakefulness in eight normal volunteers and 12 patients with narcolepsy. Electroencephalogram, electro-oculogram, and submental electromyogram were recorded simultaneously. In normals, mean hemispheric gray matter blood flow (Fg) during stages I and II sleep was significantly less than waking values. Maximum regional blood flow decreases during sleep occurred in the brainstem-cerebellar, right inferior temporal, and bilateral frontal regions. In patients with narcolepsy, mean hemispheric Fg while awake was 80.5 +- 13 ml per 100 gm brain per minute. During REM sleep, mean hemispheric Fg increased concurrently with large increases in brainstem-cerebellar region flow. During stages I and II sleep without REM, there were significant increases in mean hemispheric Fg and brainstem-cerebellar Fg, just the opposite of changes in normals. In narcolepsy, there appears to be a reversal of normal cerebral deactivation patterns, particularly involving the brainstem, during stages I and II sleep.

  20. Cerebral blood flow in patients with dementia of Alzheimer's type

    DEFF Research Database (Denmark)

    Postiglione, A; Lassen, N A; Holman, B L

    1993-01-01

    of the disease. Lateral CBF asymmetry is also very frequent; speech disorders are highly characteristic of left-sided flow reduction, while visuospatial apraxia is dominating in the right-sided cases. In advanced and severe cases of AD, CBF and metabolism tend to be more uniformly reduced throughout the cortex......In the normal brain as well as in Alzheimer's disease (AD), regional cerebral blood flow (CBF) is coupled to metabolic demand and, therefore, changes in CBF reflect variations in neuronal metabolism. The use of radionuclide techniques, such as positron emission tomography (PET) and single photon......-parieto-temporal CBF reduction is highly diagnostic for AD, despite the fact that a similar CBF pattern could also be observed in other types of dementia. Many AD patients with parieto-temporal flow reduction also have a diffuse flow reduction in the frontal cortical areas, particularly in advanced stages...

  1. Endothelial-dependent vasodilators preferentially increase subendocardial blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Pelc, L.R.; Gross, G.J.; Warltier, D.C.

    1986-03-05

    Interference with arachidonic acid metabolism on the effect of acetylcholine (Ach) or arachidonic acid (AA) to preferentially increase subendocardial perfusion was investigated in anesthetized dogs. Hemodynamics, regional myocardial blood flow (MBF (ml/min/g):radioactive microspheres) and the left ventricular transmural distribution of flow (endo/epi) were measured. Intracoronary infusion of Ach (10 ..mu..g/min) and AA (585 ..mu..g/min) significantly (P < .05*) increased myocardial perfusion and selectively redistributed flow to the subendocardium (increased endo/epi) without changes in systemic hemodynamics. Inhibition of phospholipase A/sub 2/ by quinacrine (Q; 600 ..mu..g/min, ic) attenuated the increase in myocardial perfusion produced by Ach but not by AA and inhibited the redistribution of flow to the subendocardium. The present results suggest that endothelium-dependent vasodilators produce a preferential increase in subendocardial perfusion via a product of AA metabolism.

  2. Blood transfusion in preterm infants improves intestinal tissue oxygenation without alteration in blood flow.

    Science.gov (United States)

    Banerjee, J; Leung, T S; Aladangady, N

    2016-11-01

    The objective of the study was to investigate the splanchnic blood flow velocity and oximetry response to blood transfusion in preterm infants according to postnatal age. Preterm infants receiving blood transfusion were recruited to three groups: 1-7 (group 1; n = 20), 8-28 (group 2; n = 21) and ≥29 days of life (group 3; n = 18). Superior mesenteric artery (SMA) peak systolic (PSV) and diastolic velocities were measured 30-60 min pre- and post-transfusion using Doppler ultrasound scan. Splanchnic tissue haemoglobin index (sTHI), tissue oxygenation index (sTOI) and fractional tissue oxygen extraction (sFTOE) were measured from 15-20 min before to post-transfusion using near-infrared spectroscopy. The mean pretransfusion Hb in group 1, 2 and 3 was 11, 10 and 9 g/dl, respectively. The mean (SD) pretransfusion SMA PSV in group 1, 2 and 3 was 0·63 (0·32), 0·81 (0·33) and 0·97 (0·40) m/s, respectively, and this did not change significantly following transfusion. The mean (SD) pretransfusion sTOI in group 1, 2 and 3 was 36·7 (19·3), 44·6 (10·4) and 41·3 (10·4)%, respectively. The sTHI and sTOI increased (P transfusion in all groups. On multivariate analysis, changes in SMA PSV and sTOI following blood transfusion were not associated with PDA, feeding, pretransfusion Hb and mean blood pressure. Pretransfusion baseline splanchnic tissue oximetry and blood flow velocity varied with postnatal age. Blood transfusion improved intestinal tissue oxygenation without altering mesenteric blood flow velocity irrespective of postnatal ages. © 2016 International Society of Blood Transfusion.

  3. Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI

    Energy Technology Data Exchange (ETDEWEB)

    Stankovic, Zoran [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Roessle, Martin; Schultheiss, Michael [University Medical Center Freiburg, Department of Gastroenterology, Freiburg (Germany); Euringer, Wulf; Langer, Mathias [University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Salem, Riad; Barker, Alex; Carr, James; Collins, Jeremy D. [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2015-09-15

    To assess changes in portal and splanchnic arterial haemodynamics in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) using four-dimensional (4D) flow MRI, a non-invasive, non-contrast imaging technique. Eleven patients undergoing TIPS implantation were enrolled. K-t GRAPPA accelerated non-contrast 4D flow MRI of the liver vasculature was applied with acceleration factor R = 5 at 3Tesla. Flow analysis included three-dimensional (3D) blood flow visualization using time-resolved 3D particle traces and semi-quantitative flow pattern grading. Quantitative evaluation entailed peak velocities and net flows throughout the arterial and portal venous (PV) systems. MRI measurements were taken within 24 h before and 4 weeks after TIPS placement. Three-dimensional flow visualization with 4D flow MRI revealed good image quality with minor limitations in PV flow. Quantitative analysis revealed a significant increase in PV flow (562 ± 373 ml/min before vs. 1831 ± 965 ml/min after TIPS), in the hepatic artery (176 ± 132 ml/min vs. 354 ± 140 ml/min) and combined flow in splenic and superior mesenteric arteries (770 ml/min vs. 1064 ml/min). Shunt-flow assessment demonstrated stenoses in two patients confirmed and treated at TIPS revision. Four-dimensional flow MRI might have the potential to give new information about the effect of TIPS placement on hepatic perfusion. It may explain some unexpected findings in clinical observation studies. (orig.)

  4. Three-dimensional imaging of absolute blood flow velocity and blood vessel position under low blood flow velocity based on Doppler signal information included in scattered light from red blood cells

    Science.gov (United States)

    Kyoden, Tomoaki; Akiguchi, Shunsuke; Tajiri, Tomoki; Andoh, Tsugunobu; Hachiga, Tadashi

    2017-11-01

    The development of a system for in vivo visualization of occluded distal blood vessels for diabetic patients is the main target of our research. We herein describe two-beam multipoint laser Doppler velocimetry (MLDV), which measures the instantaneous multipoint flow velocity and can be used to observe the blood flow velocity in peripheral blood vessels. By including a motorized stage to shift the measurement points horizontally and in the depth direction while measuring the velocity, the path of the blood vessel in the skin could be observed using blood flow velocity in three-dimensional space. The relationship of the signal power density between the blood vessel and the surrounding tissues was shown and helped us identify the position of the blood vessel. Two-beam MLDV can be used to simultaneously determine the absolute blood flow velocity distribution and identify the blood vessel position in skin.

  5. Outcome of splanchnic blood flow determination in patients with suspected chronic intestinal ischaemia. A retrospective survey

    DEFF Research Database (Denmark)

    Møller, Søren; Madsen, Jan Lysgård

    2002-01-01

    flow: A, normal response (splanchnic blood flow > or = 200 ml/min); B, possible abnormal response (splanchnic blood flow 51-199 ml/min); and C, definitive abnormal response (splanchnic blood flow 50 ml/min). Where surgery took place, the type of operation was noted. RESULTS: Forty patients had...

  6. Contrast agent derived determination of the total circulating blood volume using magnetic resonance.

    Science.gov (United States)

    Pannek, Kerstin; Fidler, Florian; Kartäusch, Ralf; Jakob, Peter M; Hiller, Karl-Heinz

    2012-06-01

    Knowledge of the total circulating blood volume (TCBV) is essential for the treatment of a variety of medical conditions and blood disorders. To date, blood volume analysis is rarely carried out due to the disadvantages of available methods. Our aim was to develop a widely available, simple, fast, yet accurate method for the determination of the total circulating blood volume. Magnetic resonance (MR) is a well-established, non-invasive technique. In this article, we present a method that uses MR contrast agents for the determination of the blood volume. The dependence of MR relaxation times on the concentration of MR contrast agents allows the calculation of the volume the contrast agent has been diluted in. In phantom and in vivo experiments we could demonstrate that TCBV can be determined with high accuracy and precision. This work introduces a novel method for the determination of the total circulating blood volume using magnetic resonance contrast agents as tracers.

  7. Sympathetic reflex control of blood flow in human peripheral tissues

    DEFF Research Database (Denmark)

    Henriksen, O

    1991-01-01

    sympathetic vasoconstrictor reflexes are blocked. Blood flow has been measure by the local 133Xe-technique. The results indicate the presence of spinal as well as supraspinal sympathetic vasoconstrictor reflexes to human peripheral tissues. Especially is emphasized the presence of a local sympathetic veno......Sympathetic vasoconstrictor reflexes are essential for the maintenance of arterial blood pressure in upright position. It has been generally believed that supraspinal sympathetic vasoconstrictor reflexes elicited by changes in baroreceptor activity play an important role. Recent studies on human...

  8. Cerebral blood flow autoregulation in experimental liver failure

    DEFF Research Database (Denmark)

    Dethloff, T.J.; Larsen, F.S.; Knudsen, Gitte Moos

    2008-01-01

    Patients with acute liver failure (ALF) display impairment of cerebral blood flow (CBF) autoregulation, which may contribute to the development of fatal intracranial hypertension, but the pathophysiological mechanism remains unclear. In this study, we examined whether loss of liver mass causes...... impairment of CBF autoregulation. Four rat models were chosen, each representing different aspects of ALF: galactosamine (GlN) intoxication represented liver necrosis, 90% hepatectomy (PHx90) represented reduction in liver mass, portacaval anastomosis (PCA) represented shunting of blood...... edema/high ICP. Nor does portacaval shunting or hyperammonemia impair autoregulation. Rather, massive liver necrosis and reduced liver mass are associated with loss of CBF autoregulation Udgivelsesdato: 2008/5...

  9. Tomographic cerebral blood flow measurement during carotid surgery

    DEFF Research Database (Denmark)

    Rathenborg, Lisbet Knudsen; Vorstrup, Sidsel; Olsen, K S

    1994-01-01

    OBJECTIVES: The aim of the study was to depict regional cerebral blood flow (rCBF) during carotid cross clamping using 99mTechnetium-hexamethylpropylene amine oxime (TcHMPAO). This tracer rapidly passes the blood-brain barrier and is retained for hours in the brain tissue. Injecting TcHMPAO during......, Copenhagen, Denmark. MATERIAL: 15 patients who during a period of 4 months underwent carotid endarterectomy. CHIEF OUTCOME MEASURES: Prior to surgery rCBF was determined using 133Xe and SPECT. Intraoperatively stump pressure was measured and a bolus of TcHMPAO was injected for later SPECT measurement. MAIN...

  10. Quantitative flow and velocity measurements of pulsatile blood flow with 4D-DSA

    Science.gov (United States)

    Shaughnessy, Gabe; Hoffman, Carson; Schafer, Sebastian; Mistretta, Charles A.; Strother, Charles M.

    2017-03-01

    Time resolved 3D angiographic data from 4D DSA provides a unique environment to explore physical properties of blood flow. Utilizing the pulsatility of the contrast waveform, the Fourier components can be used to track the waveform motion through vessels. Areas of strong pulsatility are determined through the FFT power spectrum. Using this method, we find an accuracy from 4D-DSA flow measurements within 7.6% and 6.8% RMSE of ICA PCVIPR and phantom flow probe validation measurements, respectively. The availability of velocity and flow information with fast acquisition could provide a more quantitative approach to treatment planning and evaluation in interventional radiology.

  11. Complex blood flow quantification using real-time in vivo vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Per, Haugaard

    A new method to define and quantify complex blood flow is presented. The standard deviations of real-time in vivo vector flow angle estimates are used. Using vector flow ultrasound imaging both carotid bifurcations of two healthy volunteers were scanned. Scanning was performed with a 7.6 MHz linear...... transducer (8670, B-K Medical, Denmark) and a commercial vector flow ultrasound scanner (ProFocus 2202, B-K Medical). Eight video sequences of one cardiac cycle were obtained. In every frame boxes were placed to define the common carotid artery(box1) and the carotid bulb(box2). The standard deviation...

  12. FDM Analysis for Blood Flow through Stenosed Tapered Arteries

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2010-01-01

    Full Text Available Abstract A computational model is developed to analyze the unsteady flow of blood through stenosed tapered narrow arteries, treating blood as a two-fluid model with the suspension of all the erythrocytes in the core region as Herschel-Bulkley fluid and the plasma in the peripheral layer as Newtonian fluid. The finite difference method is employed to solve the resulting system of nonlinear partial differential equations. The effects of stenosis height, peripheral layer thickness, yield stress, viscosity ratio, angle of tapering and power law index on the velocity, wall shear stress, flow rate and the longitudinal impedance are analyzed. It is found that the velocity and flow rate increase with the increase of the peripheral layer thickness and decrease with the increase of the angle of tapering and depth of the stenosis. It is observed that the flow rate decreases nonlinearly with the increase of the viscosity ratio and yield stress. The estimates of the increase in the longitudinal impedance to flow are considerably lower for the two-fluid Herschel-Bulkley model compared with those of the single-fluid Herschel-Bulkley model. Hence, it is concluded that the presence of the peripheral layer helps in the functioning of the diseased arterial system.

  13. Pulsatile blood flow in elastic artery with model aneurysm

    Science.gov (United States)

    Nikolov, N.; Radev, St.; Tabakova, S.

    2017-11-01

    The mathematical modeling and numerical simulations are expected to play an important role to predict the genesis of different cardiovascular diseases, such as the formation and rupture of aneurysms. In the present work, the numerical solutions of the oscillatory blood flow are constructed for an elastic artery with a model aneurysm by use of the software ANSYS. It is observed that the artery elastic strain behaves in a different way: stably or unstably depending on the different combinations between the flow parameter (outlet pressure) and the elastic modulus of the artery wall.

  14. Contribution of respiratory muscle blood flow to exercise-induced diaphragmatic fatigue in trained cyclists

    DEFF Research Database (Denmark)

    Vogiatzis, Ioannis; Athanasopoulos, Dimitris; Boushel, Robert Christopher

    2008-01-01

    We investigated whether the greater degree of exercise-induced diaphragmatic fatigue previously reported in highly trained athletes in hypoxia (compared with normoxia) could have a contribution from limited respiratory muscle blood flow. Seven trained cyclists completed three constant load 5 min...... normoxia and hypoxia, diaphragmatic fatigue is greater in hypoxia as intercostal muscle blood flow is not increased (compared with normoxia) to compensate for the reduction in PaO2, thus further compromising O(2) supply to the respiratory muscles....... exercise tests at inspired O(2) fractions (FIO2) of 0.13, 0.21 and 1.00 in balanced order. Work rates were selected to produce the same tidal volume, breathing frequency and respiratory muscle load at each FIO2 (63 +/- 1, 78 +/- 1 and 87 +/- 1% of normoxic maximal work rate, respectively). Intercostals...

  15. Vessel Segmentation and Blood Flow Simulation Using Level-Sets and Embedded Boundary Methods

    Energy Technology Data Exchange (ETDEWEB)

    Deschamps, T; Schwartz, P; Trebotich, D; Colella, P; Saloner, D; Malladi, R

    2004-12-09

    In this article we address the problem of blood flow simulation in realistic vascular objects. The anatomical surfaces are extracted by means of Level-Sets methods that accurately model the complex and varying surfaces of pathological objects such as aneurysms and stenoses. The surfaces obtained are defined at the sub-pixel level where they intersect the Cartesian grid of the image domain. It is therefore straightforward to construct embedded boundary representations of these objects on the same grid, for which recent work has enabled discretization of the Navier-Stokes equations for incompressible fluids. While most classical techniques require construction of a structured mesh that approximates the surface in order to extrapolate a 3D finite-element gridding of the whole volume, our method directly simulates the blood-flow inside the extracted surface without losing any complicated details and without building additional grids.

  16. Transfer function analysis for the assessment of cerebral autoregulation using spontaneous oscillations in blood pressure and cerebral blood flow

    NARCIS (Netherlands)

    van den Abeelen, Aisha; Beek, Arenda H.E.A.; Slump, Cornelis H.; Panerai, Ronney B.; Claassen, Jurgen A.H.R.

    2014-01-01

    Cerebral autoregulation (CA) is a key mechanism to protect the brain against excessive fluctuations in blood pressure (BP) and maintain cerebral blood flow. Analyzing the relationship between spontaneous BP and cerebral blood flow velocity (CBFV) using transfer function analysis is a widely used

  17. Simulation of branching blood flows on parallel computers.

    Science.gov (United States)

    Yue, Xue; Hwang, Feng-Nan; Shandas, Robin; Cai, Xiao-Chuan

    2004-01-01

    We present a fully parallel nonlinearly implicit algorithm for the numerical simulation of some branching blood flow problems, which require efficient and robust solver technologies in order to handle the high nonlinearity and the complex geometry. Parallel processing is necessary because of the large number of mesh points needed to accurately discretize the system of differential equations. In this paper we introduce a parallel Newton-Krylov-Schwarz based implicit method, and software for distributed memory parallel computers, for solving the nonlinear algebraic systems arising from a Q2-Q1 finite element discretization of the incompressible Navier-Stokes equations that we use to model the blood flow in the left anterior descending coronary artery.

  18. Subcutaneous blood flow in early male pattern baldness

    Energy Technology Data Exchange (ETDEWEB)

    Klemp, P.; Peters, K.; Hansted, B.

    1989-05-01

    The subcutaneous blood flow (SBF) was measured by the /sup 133/Xe washout method in the scalp of 14 patients with early male pattern baldness. Control experiments were performed in 14 normal haired men matched for age. The SBF in the scalp of the normal individuals was about 10 times higher than previously reported SBF values in other anatomical regions. In patients with early male pattern baldness, SBF was 2.6 times lower than the values found in the normal individuals (13.7 +/- 9.6 vs 35.7 +/- 10.5 ml/100 g/min-1). This difference was statistically significant (p much less than 0.001). A reduced nutritive blood flow to the hair follicles might be a significant event in the pathogenesis of early male pattern baldness.

  19. Regulation of the skeletal muscle blood flow in humans

    DEFF Research Database (Denmark)

    Mortensen, Stefan; Saltin, Bengt

    2014-01-01

    hyperaemia whereas the role of ATP remains uncertain due to lack of specific purinergic receptor blockers for human use. The purpose of this review is to address the interaction between vasodilator systems and to discuss the multiple proposed roles of ATP in human skeletal muscle blood flow regulation......In humans, skeletal muscle blood flow is regulated by an interaction between several locally formed vasodilators including nitric oxide (NO) and prostaglandins. In plasma, ATP is a potent vasodilator that stimulates the formation of NO and prostaglandins and very importantly can offset local...... sympathetic vasoconstriction. ATP is released into plasma from erythrocytes and endothelial cells and the plasma concentration increases in both the feeding artery and the vein draining the contracting skeletal muscle. Adenosine also stimulates the formation of NO and prostaglandins, but the plasma adenosine...

  20. Assessment of maternal cerebral blood flow in patients with preeclampsia

    OpenAIRE

    Mandić Vesna; Miković` Željko; Đukić Milan; Vasiljević Mladenko; Filimonović Dejan; Bogavac Mirjana

    2005-01-01

    Introduction Systemic vasoconstrktion in preeclamptic patients increases vascular resistance, and is manifested by increased arterial blood flow velocity. The aim of the study is to evaluate if there is a change of Doppler indices in maternal medial cerbral artery (MCA) in severe preeclampsia due to: 1) severity of clinical symptoms, 2) the beginning of eclamptic attack and 3) the application of anticonvidsive therapy. Material and methods A prospective clinical study included 92 pregnant wom...

  1. Feasibility of patient specific aortic blood flow CFD simulation.

    Science.gov (United States)

    Svensson, Johan; Gårdhagen, Roland; Heiberg, Einar; Ebbers, Tino; Loyd, Dan; Länne, Toste; Karlsson, Matts

    2006-01-01

    Patient specific modelling of the blood flow through the human aorta is performed using computational fluid dynamics (CFD) and magnetic resonance imaging (MRI). Velocity patterns are compared between computer simulations and measurements. The workflow includes several steps: MRI measurement to obtain both geometry and velocity, an automatic levelset segmentation followed by meshing of the geometrical model and CFD setup to perform the simulations follwed by the actual simulations. The computational results agree well with the measured data.

  2. The Effect of Insulating Blood Warmer Output Tubing on the Temperature of Packed Red Blood Cells at Low Flow Rates

    Science.gov (United States)

    1989-01-01

    blood cells at the point of patient entry at low flow rates . Utilizing a surgical suite, every attempt was made to replicate a true surgical setting...Flow control pumps were used to regulate flow rates of 300, 600, and 900 milliliters per hour (ml/hr) through Fenwall Laboratories blood warming coils

  3. Orthostatic leg blood volume changes assessed by near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Truijen, J; Kim, Y S; Krediet, C T P

    2012-01-01

    Standing up shifts blood to dependent parts of the body, and blood vessels in the leg become filled. The orthostatic blood volume accumulation in the small vessels is relatively unknown, although these may contribute significantly. We hypothesized that in healthy humans exposed to the upright pos......-linear accumulation of blood volume in the small vessels of the leg, with an initial fast phase followed by a more gradual increase at least partly contributing to the relocation of fluid during orthostatic stress....

  4. Splanchnic blood flow and hepatic glucose production in exercising humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L

    2001-01-01

    The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin-converti......The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin......-converting enzyme (ACE) blockade] or without (control) administration of the ACE inhibitor enalapril (10 mg iv). Splanchnic blood flow was estimated by indocyanine green, and splanchnic substrate exchange was determined by the arteriohepatic venous difference. Exercise led to an approximately 20-fold increase (P ... blockade; 0.74 +/- 0.14 l/min, control), whereas splanchnic glucose production (at rest: 0.50 +/- 0.06, ACE blockade; 0.68 +/- 0.10 mmol/min, control) increased during moderate exercise (1.97 +/- 0.29, ACE blockade; 1.91 +/- 0.41 mmol/min, control). Refuting a major role of the RAS for these responses...

  5. Pulsed photoacoustic Doppler flow measurements in blood-mimicking phantoms

    Science.gov (United States)

    Brunker, J.; Beard, P.

    2011-03-01

    The feasibility of making spatially resolved measurements of blood flow using pulsed photoacoustic Doppler techniques has been explored. Doppler time shifts were quantified via cross-correlation of pairs of photoacoustic waveforms generated within a blood-simulating phantom using pairs of laser light pulses. The photoacoustic waves were detected using a focussed or planar PZT ultrasound transducer. For each flow measurement, a series of 100 waveform pairs was collected. Previous data processing methods involved rejection of poorly correlated waveform pairs; the modal velocity value and standard deviation were then extracted from the selected distribution of velocity measurements. However, the data selection criteria used in this approach is to some extent arbitrary. A new data analysis protocol, which involves averaging the 100 cross-correlation functions and thus uses all of the measured data, has been designed in order to prevent exclusion of outliers. This more rigorous approach has proved effective for quantifying the linear motion of micron-scale absorbers imprinted on an acetate sheet moving with velocities in the range 0.14 to 1.25 ms-1. Experimental parameters, such as the time separation between the laser pulses and the transducer frequency response, were evaluated in terms of their effect on the accuracy, resolution and range of measurable velocities. The technique was subsequently applied to fluid phantoms flowing at rates less than 5 mms-1 along an optically transparent tube. Preliminary results are described for three different suspensions of phenolic resin microspheres, and also for whole blood. Velocity information was obtained even under non-optimal conditions using a low frequency transducer and a low pulse repetition frequency. The distinguishing advantage of pulsed rather than continuous-wave excitation is that spatially resolved velocity measurements can be made. This offers the prospect of mapping flow within the microcirculation and thus

  6. Sevoflurane effects on retrobulbar arteries blood flow in children.

    Science.gov (United States)

    Geeraerts, T; Devys, J-M; Berges, O; Dureau, P; Plaud, B

    2005-05-01

    Measure of blood flow velocity in retrobulbar vessels is performed to determine the severity of ophthalmic pathologies as glaucoma. In children, this measure is usually performed under general anaesthesia. Sevoflurane is known to not modify cerebral blow flow velocities. However, its effect on retrobulbar circulation is not known. This study was designed to evaluate the effect of sevoflurane on retrobulbar circulation flow velocity in children undergoing examination for ocular disorders under general anaesthesia. Thirteen mechanically ventilated children (Fi(O2))=1) were included. Blood flow velocities of central retinal artery, ophthalmic artery, and middle cerebral artery were measured by Doppler ultrasound during 1 and 2 age-adjusted minimal alveolar concentration (MAC) sevoflurane anaesthesia. Intra-ocular pressure and non-invasive haemodynamic parameters were also measured. End-tidal carbon dioxide tension was controlled during all the study period. Mean arterial pressure decreased from 1 to 2 age-adjusted MAC sevoflurane (58 [12] vs 54 [12] mm Hg, P=0.01). In the ophthalmic artery, end diastolic velocity (EDV) decreased significantly at 2 MAC (1 MAC: 4.4 [4] cm s(-1) vs 2 MAC: 1.4 [2.4] cm s(-1); P=0.04) and resistivity index (RI) increased significantly (1 MAC: 0.83 [0.11] vs 2 MAC: 0.93 [0.09]; P=0.007). Systolic velocity, EDV, and RI remained constant in the central retinal artery and in the middle cerebral artery. High alveolar concentration of sevoflurane decreased blood flow velocity in the ophthalmic artery, but not in the central retinal and the middle cerebral arteries in children ventilated in hyperoxic condition. This effect was related to a decrease in mean arterial pressure. This vessel-dependent effect may be explained by the different autoregulatory mechanisms of these arteries. In the present hyperoxic conditions, the vascular effect of sevoflurane may have been limited in the central retinal artery and not in the ophthalmic artery.

  7. Recent advances in blood flow vector velocity imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav; Udesen, Jesper

    2011-01-01

    A number of methods for ultrasound vector velocity imaging are presented in the paper. The transverse oscillation (TO) method can estimate the velocity transverse to the ultrasound beam by introducing a lateral oscillation in the received ultrasound field. The approach has been thoroughly...... investigated using both simulations, flow rig measurements, and in-vivo validation against MR scans. The TO method obtains a relative accuracy of 10% for a fully transverse flow in both simulations and flow rig experiments. In-vivo studies performed on 11 healthy volunteers comparing the TO method...... with magnetic resonance phase contrast angiography (MRA) revealed a correlation between the stroke volume estimated by TO and MRA of 0.91 (pflow in e.g. bifurcations and around valves have...

  8. Nitric oxide and prostaglandins influence local skeletal muscle blood flow during exercise in humans: coupling between local substrate uptake and blood flow

    DEFF Research Database (Denmark)

    Kalliokoski, Kari K; Langberg, Henning; Ryberg, Ann Kathrine

    2006-01-01

    Synergic action of nitric oxide (NO) and prostaglandins (PG) in the regulation of muscle blood flow during exercise has been demonstrated. In the present study, we investigated whether these vasodilators also regulate local blood flow, flow heterogeneity, and glucose uptake within the exercising...

  9. The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon.

    Science.gov (United States)

    Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Ozcan; Sahin, Mahmut

    2014-09-01

    The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Patients' demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow.

  10. Analyzing Circle of Willis blood flow in ischemic stroke patients through 3D Stroke Arterial Flow Estimation.

    Science.gov (United States)

    Chien, Aichi; Viñuela, Fernando

    2017-08-01

    Background The objective of ischemic stroke (IS) treatment is to achieve revascularization in cerebral arteries to restore blood flow. However, there is no available method to extract arterial flow data from clinical CTA images. We developed 3D Stroke Arterial Flow Estimation (SAFE), which provides blood flow data throughout the Circle of Willis based on 3D CTA and allows comparison of arterial flow distribution in the brain. Methods We implemented a newly developed 3D vascular reconstruction algorithm for clinical stroke CTA images. Based on the patient-specific vascular structure, SAFE calculates time-resolved blood flow information for the entire Circle of Willis and allows quantitative flow study of IS cases. Clinical IS cases are presented to demonstrate the feasibility. Four patients with CTA images and CT perfusion data were studied. To validate the SAFE analysis, correlation analysis comparing blood flow at the MCA, ICA, and BA was performed. Results Different blood flow patterns were found in individual IS patients. Altered flow patterns and high collateral flow rates were found near occlusions in all cases. Quantitative comparison of blood flow data showed that SAFE obtained flow data and CTP were significantly correlated and provide complementary information about cerebral blood flow for individual patients. Conclusions We present SAFE analysis for collecting detailed time-resolved cerebral arterial flow data in the entire Circle of Willis for IS. Further study with more cases may be important to test the clinical utilization of SAFE and helpful to the study of the underlying hemodynamics of stroke.

  11. Repeatability of Doppler ultrasonographic measurement of equine digital blood flow.

    Science.gov (United States)

    Menzies-Gow, Nicola J; Marr, Celia M

    2007-01-01

    The repeatability and sensitivity of Doppler ultrasonographic measurement of lateral digital arterial and venous blood flow has not been previously determined. Doppler ultrasonography was used to measure blood flow within the forelimb lateral digital vessels in one normal adult Thoroughbred horse on six occasions and in six normal adult Thoroughbred horses on three occasions, each occasion being at least 1 h apart, to determine the within- and between-horse variation. The values obtained from the right and left lateral digital vessels did not differ significantly. The within-horse coefficients of variation (CV) for arterial and venous measurements were all acceptable ( or = 0.71) for all parameters except venous diameter; the between-horse ICC demonstrated good to excellent repeatability (> or = 0.67) for all parameters except TaVb. Doppler ultrasonography can detect differences of 0.005 and 0.01 ml/ min in digital arterial and venous flow, respectively, using measurements from six horses on three occasions (80% power; P < 0.05). Thus, the technique is sufficiently repeatable and sensitive to be able to detect changes in flow during different physiological or pathological states or following pharmacologic intervention.

  12. [Cerebral blood flow assessment of preterm infants during respiratory therapy with the expiratory flow increase technique].

    Science.gov (United States)

    Bassani, Mariana Almada; Caldas, Jamil Pedro Siqueira; Netto, Abimael Aranha; Marba, Sérgio Tadeu Martins

    2016-06-01

    To assess the impact of respiratory therapy with the expiratory flow increase technique on cerebral hemodynamics of premature newborns. This is an intervention study, which included 40 preterm infants (≤34 weeks) aged 8-15 days of life, clinically stable in ambient air or oxygen catheter use. Children with heart defects, diagnosis of brain lesion and/or those using vasoactive drugs were excluded. Ultrasonographic assessments with transcranial Doppler flowmetry were performed before, during and after the increase in expiratory flow session, which lasted 5minutes. Cerebral blood flow velocity and resistance and pulsatility indices in the pericallosal artery were assessed. Respiratory physical therapy did not significantly alter flow velocity at the systolic peak (p=0.50), the end diastolic flow velocity (p=0.17), the mean flow velocity (p=0.07), the resistance index (p=0.41) and the pulsatility index (p=0.67) over time. The expiratory flow increase technique did not affect cerebral blood flow in clinically-stable preterm infants. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  13. Cerebral blood flow assessment of preterm infants during respiratory therapy with the expiratory flow increase technique

    Directory of Open Access Journals (Sweden)

    Mariana Almada Bassani

    2016-06-01

    Full Text Available Abstract Objective: To assess the impact of respiratory therapy with the expiratory flow increase technique on cerebral hemodynamics of premature newborns. Methods: This is an intervention study, which included 40 preterm infants (≤34 weeks aged 8-15 days of life, clinically stable in ambient air or oxygen catheter use. Children with heart defects, diagnosis of brain lesion and/or those using vasoactive drugs were excluded. Ultrasonographic assessments with transcranial Doppler flowmetry were performed before, during and after the increase in expiratory flow session, which lasted 5min. Cerebral blood flow velocity and resistance and pulsatility indices in the pericallosal artery were assessed. Results: Respiratory physical therapy did not significantly alter flow velocity at the systolic peak (p=0.50, the end diastolic flow velocity (p=0.17, the mean flow velocity (p=0.07, the resistance index (p=0.41 and the pulsatility index (p=0.67 over time. Conclusions: The expiratory flow increase technique did not affect cerebral blood flow in clinically-stable preterm infants.

  14. Renal blood flow and metabolism after cold ischaemia

    DEFF Research Database (Denmark)

    Henriksen, J H; Petersen, H K

    1984-01-01

    .01) immediately after re-established perfusion and 36% (P less than 0.02) 30 min later. In one additional patient, who had a short warm ischaemia (8 min), the flow pattern was the same. As arterial pressure remained constant, the reduced RBF signifies an increased renal vascular resistance. Renal O2-uptake......Peroperative measurements of renal blood flow (RBF), renal O2-uptake, and renal venous lactate/pyruvate (L/P) ratio were performed before and after a period of 30-71 min of hypothermic (10-15 degrees C) renal ischaemia in nine patients, undergoing surgery for renal calculi. Before ischaemia, RBF...... and renal venous L/P ratio were almost constant, indicating no significant anaerobic processes being involved in the flow response. None of the patients showed any signs of reactive hyperaemia. It is concluded that hypothermic renal ischaemia may be followed by an increased renal vascular resistance even...

  15. A Volume-Fraction Based Two-Phase Constitutive Model for Blood

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Rui (Carnegie-Mellon Univ.); Massoudi, Mehrdad; Hund, S.J. (Carnegie-Mellon Univ.); •Antaki, J.F. (Carnegie-Mellon Univ.)

    2008-06-01

    Mechanically-induced blood trauma such as hemolysis and thrombosis often occurs at microscopic channels, steps and crevices within cardiovascular devices. A predictive mathematical model based on a broad understanding of hemodynamics at micro scale is needed to mitigate these effects, and is the motivation of this research project. Platelet transport and surface deposition is important in thrombosis. Microfluidic experiments have previously revealed a significant impact of red blood cell (RBC)-plasma phase separation on platelet transport [5], whereby platelet localized concentration can be enhanced due to a non-uniform distribution of RBCs of blood flow in a capillary tube and sudden expansion. However, current platelet deposition models either totally ignored RBCs in the fluid by assuming a zero sample hematocrit or treated them as being evenly distributed. As a result, those models often underestimated platelet advection and deposition to certain areas [2]. The current study aims to develop a two-phase blood constitutive model that can predict phase separation in a RBC-plasma mixture at the micro scale. The model is based on a sophisticated theory known as theory of interacting continua, i.e., mixture theory. The volume fraction is treated as a field variable in this model, which allows the prediction of concentration as well as velocity profiles of both RBC and plasma phases. The results will be used as the input of successive platelet deposition models.

  16. Occlusion cuff for routine measurement of digital blood pressure and blood flow

    DEFF Research Database (Denmark)

    Lassen, N A; Krähenbühl, B; Hirai, M

    1977-01-01

    A miniaturized blood pressure cuff made of plastic material and applicable to fingers and toes is described. The cuff was compared to rubber cuffs and to bladder-free cuffs. It was found to be more reliable than the former type and much easier to use than the latter type. It is recommended for us...... in conjunction with a mercury-in-Silastic strain gauge for routine measurement of digital blood pressure and blood flow in patients with arterial disease.......A miniaturized blood pressure cuff made of plastic material and applicable to fingers and toes is described. The cuff was compared to rubber cuffs and to bladder-free cuffs. It was found to be more reliable than the former type and much easier to use than the latter type. It is recommended for use...

  17. The Effect of the Ovarian Endometrioma Surgery on Ovarian Reserve and Ovarian Blood Flow

    Directory of Open Access Journals (Sweden)

    Manolya Yilmaz

    2014-03-01

    Full Text Available Aim: To investigate the effectiveness of laparoscopic endometriosis surgery on ovarian reserve and ovarian blood flow index. Material and Method: Twenty-six patients were evaluated prospectively whom had laparoscopic surgery due to endometrioma in third care education and research hospital. Before and after surgical procedure all patients FSH, LH and E2 levels were measured in their 3rd menstrual period day. Periodically cysts and ovarian volume as well as ovarian artery resistive index measured by using transvaginal Doppler sonography. Results: Twenty-six patients%u2019 mean age was 25, 6 ± 4, 5 (20-36 years. When the compared to changes of preoperative and postoperative values of hormonal parameters FSH (p: 0,455 and LH (p: 0,672 were insignificant and E2 (p: 0,024 was significant respectively. While ovarian volume was decreasing significantly (p: 0,001, Ovarian Artery RI parameter was not changed (p: 0,587. Discussion: Our study was showed that while laparoscopic surgical treatment of ovarian endometriomas significantly decrease ovarian volume, but hormonal parameters and ovarian blood flow were not affected.

  18. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve...... that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein......., corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...

  19. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve......, corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...... arrest. The mean T2 of non-flowing blood was found to be 105 +/- 31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate...

  20. Dynamical evolution of volume fractions in multipressure multiphase flow models.

    Science.gov (United States)

    Chang, C H; Ramshaw, J D

    2008-06-01

    Compared to single-pressure models, multipressure multiphase flow models require additional closure relations to determine the individual pressures of the different phases. These relations are often taken to be evolution equations for the volume fractions. We present a rigorous theoretical framework for constructing such equations for compressible multiphase mixtures in terms of submodels for the relative volumetric expansion rates DeltaE_{i} of the phases. These quantities are essentially the rates at which the phases dynamically expand or contract in response to pressure differences, and represent the general tendency of the volume fractions to relax toward values that produce local pressure equilibrium. We present a simple provisional model of this type in which DeltaE_{i} is proportional to pressure differences divided by the time required for sound waves to traverse an appropriate characteristic length. It is shown that the resulting approach to pressure equilibrium is monotonic rather than oscillatory, and occurs instantaneously in the incompressible limit.

  1. Outcome of splanchnic blood flow determination in patients with suspected chronic intestinal ischaemia. A retrospective survey

    DEFF Research Database (Denmark)

    Møller, Søren; Madsen, Jan Lysgård

    2002-01-01

    flow: A, normal response (splanchnic blood flow > or = 200 ml/min); B, possible abnormal response (splanchnic blood flow 51-199 ml/min); and C, definitive abnormal response (splanchnic blood flow ... a normal meal-induced response, 23 patients had a possible abnormal response and 10 patients had a definitive abnormal response, which gave evidence of chronic intestinal ischaemia. In the total patient population, the increase in splanchnic blood flow was significantly correlated to an increase in hepatic...... oxygen uptake (r = 0.38, P abnormal meal-induced splanchnic blood flow and 30% of these patients...

  2. The hydrogen gas clearance method for liver blood flow examination: inhalation or local application of hydrogen?

    Science.gov (United States)

    Metzger, H P

    1989-01-01

    The combined method of hydrogen inhalation and local hydrogen production enable the determination of hepatic blood flow (HBF) and local hepatic blood flow (LHBF). LHBF was registered within a small superficial tissue volume of 0.5 mm in diameter by means of a multi-wire electrode having 200 microns producing and 100 microns measuring wires arranged within less than 300 microns distance between the measuring wires. The feeding current for hydrogen production was 1 microA, the potential less than 10 V. The clearance in response to inhalation was registered by means of the same measuring electrodes within the same tissue volume. Spontaneously breathing rats (Wistar-Frömter strain, 180-230 g bw, N = 19, ketamin-xylazine anesthesia, artificial respiration) showed the following flow values: HBF +/- SD = 0.50 +/- 0.26 ml/g.min, n = 48 registrations; LHBF +/- SD = 4.66 +/- 2.13 ml/g.min, n = 43. The validity of the combined method is demonstrated in the LHBF/HBF graph which summarizes the data of hemorrhagic and control animals, m = 0.1 and yo = 0.001. The correlation coefficient of r = 0.685 shows a reasonable correlation of the combined data despite the wide scattering of the individual values.

  3. The effect of glucagon-like peptide-2 on arterial blood flow and cardiac parameters

    DEFF Research Database (Denmark)

    Bremholm, Lasse; Hornum, Mads; Andersen, Ulrik B

    2010-01-01

    Glucagon-like peptide-2 (GLP-2) is known to increase mesenteric blood flow. The aim of the study was to evaluate the effect of GLP-2 on blood flow in different vascular sites, and dynamic changes in cardiac parameters.......Glucagon-like peptide-2 (GLP-2) is known to increase mesenteric blood flow. The aim of the study was to evaluate the effect of GLP-2 on blood flow in different vascular sites, and dynamic changes in cardiac parameters....

  4. In Vivo Validation of Volume Flow Measurements of Pulsatile Flow Using a Clinical Ultrasound System and Matrix Array Transducer.

    Science.gov (United States)

    Hudson, John M; Williams, Ross; Milot, Laurent; Wei, Qifeng; Jago, James; Burns, Peter N

    2017-03-01

    The goal of this study was to evaluate the accuracy of a non-invasive C-plane Doppler estimation of pulsatile blood flow in the lower abdominal vessels of a porcine model. Doppler ultrasound measurements from a matrix array transducer system were compared with invasive volume flow measurements made on the same vessels with a surgically implanted ultrasonic transit-time flow probe. For volume flow rates ranging from 60 to 750 mL/min, agreement was very good, with a Pearson correlation coefficient of 0.97 (p < 0.0001) and a mean bias of -4.2%. The combination of 2-D matrix array technology and fast processing gives this Doppler method clinical potential, as many of the user- and system-dependent parameters of previous methods, including explicit vessel angle and diameter measurements, are eliminated. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. ASSESSMENT OF VERTEBRAL ARTERIES BLOOD FLOW SPECTRAL DOPPLER INDICES IN COMPARISON WITH INTERNAL AND COMMON CAROTID ARTERIES BLOOD FLOW SPECTRAL DOPPLER INDICES

    Directory of Open Access Journals (Sweden)

    H. Mazaher

    2007-05-01

    Full Text Available Vertebrobasilar insufficiency is the cause of cerebrovascular accidents in 20% of cases. There are few reports regarding spectral Doppler indices (SDIs of vertebral arteries (VAs normal blood flow. The objective of this study was to provide basic reference data about SDIs of VAs normal blood flow separately and in comparison with internal carotid arteries (ICAs and common carotid arteries (CCAs normal blood flows SDIs. This cross-sectional study performed on 70 normal patients. Color Doppler sonography (CDS and spectral Doppler sonography (SDS of right and left VAs (RVA and LVA, right and left CCAs (RCCA and LCCA, right and left ICAs (RICA and LICA, were performed. The mean PSV, EDV, and RI values of RVA blood flow were as 41.60 ± 9.6 cm/s, 14.60 ± 3.7 cm/s and 0.65 ± 0.06, and the mean PSV, EDV and RI values of LVA blood flow were as 42.20 ± 10.2 cm/s, 15.20 ± 4.2 cm/s, and 0.64 ± 0.05, respectively. There was not statistically significant difference between the mean PSV, EDV and RI values of RVA and LVA blood flows. The mean PSV and EDV values of VAs blood flows were significantly lower than the values of CCAs and ICCAs blood flows, respectively. The mean RI value of VAs blood flows was significantly lower than the mean RI Value of CCAs blood flows, but there was not statistically significant difference between the mean RI value of VAs blood flows and the mean RI value of ICAs blood flows.

  6. Fluid mechanics experiments in oscillatory flow. Volume 1: Report

    Science.gov (United States)

    Seume, J.; Friedman, G.; Simon, T. W.

    1992-01-01

    Results of a fluid mechanics measurement program in oscillating flow within a circular duct are presented. The program began with a survey of transition behavior over a range of oscillation frequency and magnitude and continued with a detailed study at a single operating point. Such measurements were made in support of Stirling engine development. Values of three dimensionless parameters, Re(sub max), Re(sub w), and A(sub R), embody the velocity amplitude, frequency of oscillation and mean fluid displacement of the cycle, respectively. Measurements were first made over a range of these parameters which included operating points of all Stirling engines. Next, a case was studied with values of these parameters that are representative of the heat exchanger tubes in the heater section of NASA's Stirling cycle Space Power Research Engine (SPRE). Measurements were taken of the axial and radial components of ensemble-averaged velocity and rms-velocity fluctuation and the dominant Reynolds shear stress, at various radial positions for each of four axial stations. In each run, transition from laminar to turbulent flow, and its reverse, were identified and sufficient data was gathered to propose the transition mechanism. Models of laminar and turbulent boundary layers were used to process the data into wall coordinates and to evaluate skin friction coefficients. Such data aids in validating computational models and is useful in comparing oscillatory flow characteristics to those of fully-developed steady flow. Data were taken with a contoured entry to each end of the test section and with flush square inlets so that the effects of test section inlet geometry on transition and turbulence are documented. Volume 1 contains the text of the report including figures and supporting appendices. Volume 2 contains data reduction program listings and tabulated data (including its graphical presentation).

  7. Saline-induced natriuresis and renal blood flow in conscious dogs: effects of sodium infusion rate and concentration

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H

    2005-01-01

    AIM: This study focused on static and dynamic changes in total renal blood flow (RBF) during volume expansion and tested whether a change in RBF characteristics is a necessary effector mechanism in saline-induced natriuresis. METHODS: The aortic flow subtraction technique was used to measure RBF...... saline loading simulating daily sodium intake, the rate of sodium excretion may increase 10-20-fold without any change in mean arterial blood pressure or in RBF. Regulatory responses to changes in total body NaCl levels appears, therefore, to be mediated primarily by neurohumoral mechanisms and may occur...

  8. Ovarian parameters and ovarian blood flow of women living in the area of environmental crisis.

    Science.gov (United States)

    Balmagambetova, Aru; Abdelazim, Ibrahim A; Bekmukhambetov, Erbol; Zhurabekova, Gulmira; Yehia, Amr H; AbuFaza, Mohannad

    2016-05-01

    Exposure to environmental hazards will destroy a number of ovarian primordial follicles, reduce ovarian reserve and subsequent reproductive ability. This study designed to evaluate ovarian parameters and ovarian blood flow of women living in the area of environmental crisis Shalkar city (Kazakhstan) compared to women living in Aktobe city (Kazakhstan). 220 women in their reproductive age studied and classified into two groups; study (Shalkar) group and control (Aktobe) group. Blood sample taken from studied women during follicular phase (day 3) for hormonal level evaluation including; follicle stimulating hormone (FSH) and anti-Mullerian hormone (AMH). Studied women evaluated using trans-vaginal ultrasound (TVS) to detect antral follicle count (AFC) during follicular scan and ovarian volume (OV), ovarian blood flow (OBF) using pulsatility index (PI) during follicular scan and luteal scan. Both ovaries AFC was significantly less in study (Shalkar) group compared to and control (Aktobe) group (p=0.0001). Mean ovarian volume was significantly less in Shalkar group in both follicular phase and luteal phase (5.86±0.23 and 6.19±0.22Cm(3); respectively) compared to Aktobe group (6.85±0.19 and 6.92±0.18Cm(3); respectively). In addition, mean ovarian pulsatility index was significantly high with subsequent decrease in ovarian blood flow in Shalkar group in both follicular phase and luteal phase (3.36±0.20 and 3.45±0.19Cm/s; respectively) compared to Aktobe group (2.96±0.16 and 2.92±0.15Cm/s; respectively). This study suggests definite environmental effect on ovarian parameters as indicated by decreased AFC, decreased both follicular and luteal OV and OBF in women living in environmental crisis Shalkar group compared to Aktobe group. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Pulse dye densitometry: a novel bedside monitor of circulating blood volume.

    Science.gov (United States)

    Goy, R W; Chiu, J W; Loo, C C

    2001-03-01

    Monitoring of circulating blood volume is important in the management of critically ill patients. Current methods of circulating blood volume measurements such as indicator dilution using radioisotopes or Evans blue dye are unsuitable for clinical application as these tests do not allow for frequent repeated measurements to be done. A direct bedside measurement of circulating blood volume using the principle of pulse dye densitometry was recently introduced. This is essentially an indicator dilution technique using indocyanine green combined with the principle of pulse spectrophotometry. This paper aims to review this method of circulating blood volume measurement and provide a summary of the published clinical trials that compared its accuracy with the other conventional methods of circulating blood volume measurement, based on a Medline search, spanning the period 1966 to August 2000. Published studies show that pulse dye densitometry gives comparable results when compared to other conventional methods of blood volume measurement. Its ability to measure circulating blood volume accurately and repeatedly, as frequently as every 20 min makes it suitable for clinical application. Pulse dye densitometry provides for a rapid, semi-noninvasive and convenient bedside assessment of circulating blood volume that is applicable clinically. Further studies are needed to ascertain the impact of the use of pulse dye densitometry on the mortality and morbidity of the critically ill.

  10. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, M.R.; de Witt Hamer, P.C.; van Boven, L.J.; Zwinderman, K.A.H.; Bouma, G.J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  11. Heterogeneity of cerebral blood flow: a fractal approach

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T.; Hartikainen, P. [Department of Clinical Physiology, Kuopioo Univ. Hospital (Finland); Department of Neurology, Kuopio Univ. Hosspital (Finland); Niuvanniemi Hospital, Kuopio (Finland)

    2000-07-01

    Aim: We demonstrate the heterogeneity of regional cerebral blood flow using a fractal approach and single-photon emission computed tomography (SPECT). Method: Tc-99m-labelled ethylcysteine dimer was injected intravenously in 10 healthy controls and in 10 patients with dementia of frontal lobe type. The head was imaged with a gamma camera and transaxial, sagittal and coronal slices were reconstructed. Two hundred fifty-six symmetrical regions of interest (ROIs) were drawn onto each hemisphere of functioning brain matter. Fractal analysis was used to examine the spatial heterogeneity of blood flow as a function of the number of ROIs. Results: Relative dispersion (=coefficient of variation of the regional flows) was fractal-like in healthy subjects and could be characterized by a fractal dimension of 1.17{+-}0.05 (mean{+-}SD) for the left hemisphere and 1.15{+-}0.04 for the right hemisphere, respectively. The fractal dimension of 1.0 reflects completely homogeneous blood flow and 1.5 indicates a random blood flow distribution. Patients with dementia of frontal lobe type had a significantly lower fractal dimension of 1.04{+-}0.03 than in healthy controls. (orig.) [German] Ziel: Unter Einsatz einer fraktalen Annaeherung und SPECT wird die Heterogenitaet der regionalen Hirndruchblutung demonstriert. Methode: Tc-99m-ECD wurde nach intravenoeser Injektion bei zehn Gesunden sowie bei zehn Patienten mit Demenz vom Frontallappen-Typ eingesetzt. Aus dem SPECT-Umlauf wurden transaxiale, sagittale und koronare Schnitte rekonstruiert. 265 symmetrische Regions of Interest wurden im Gebiet der funktionellen grauen Substanz fuer jede Hemisphaere markiert. Die fraktale Analyse wurde eingesetzt zur Bestimmung der raeumlichen Heterogenitaet der Hirndurchblutung als Funktion der ROI-Anzahl. Ergebnisse: Die relative Streuung (Variationskoeffizient der regionalen Durchblutung) war bei Gesunden fraktalaehnlich geordnet und konnte durch eine Fraktaldimension von 1,17{+-}0,05 (Mittelwert

  12. Associations between total cerebral blood flow and age related changes of the brain.

    Directory of Open Access Journals (Sweden)

    Adriaan C G M van Es

    Full Text Available BACKGROUND AND PURPOSE: Although total cerebral blood flow (tCBF is known to be related to age, less is known regarding the associations between tCBF and the morphologic changes of the brain accompanying cerebral aging. The purpose of this study was to investigate whether total cerebral blood flow (tCBF is related to white matter hyperintensity (WMH volume and/or cerebral atrophy. Furthermore, we investigate whether tCBF should be expressed in mL/min, as was done in all previous MR studies, or in mL/100 mL/min, which yielded good results in precious SPECT, PET and perfusion MRI studies investigating regional cerebral blood flow. MATERIALS AND METHODS: Patients were included from the nested MRI sub-study of the PROSPER study. Dual fast spin echo and FLAIR images were obtained in all patients. In addition, single slice phase contrast MR angiography was used for flow measurements in the internal carotids and vertebral arteries. tCBF was expressed in both mL/min and mL/100 mL/min. RESULTS: We found a significant correlation between tCBF in mL/min and both age (r = -.124; p = pvolume (r = 0.430; pvolume (r = -.069; p = .148. When tCBF was expressed in mL/100 mL/min the correlation between tCBF and age was no longer found (r = -.001; p = .985. Multivariate regression analyses corrected for age showed a significant correlation between tCBF in mL/100 mL/min and WMH volume (r = -.106; p = .044. No significant association between tCBF in mL/100 mL/min and %-atrophy was found. CONCLUSION: From this study we conclude that, when evaluating tCBF alterations due to various pathologies, tCBF should in mL/100 mL/min instead of mL/min. Furthermore, changes or differences in WMH volume should be accounted for.

  13. Impact of extracorporeal blood flow rate on blood pressure, pulse rate and cardiac output during haemodialysis

    DEFF Research Database (Denmark)

    Schytz, Philip Andreas; Mace, Maria Lerche; Soja, Anne Merete Boas

    2015-01-01

    BACKGROUND: If blood pressure (BP) falls during haemodialysis (HD) [intradialytic hypotension (IDH)] a common clinical practice is to reduce the extracorporeal blood flow rate (EBFR). Consequently the efficacy of the HD (Kt/V) is reduced. However, only very limited knowledge on the effect......L/min diastolic BP, mean arterial pressure, PR and CO remained unchanged. CONCLUSION: Our study does not show any consistent trend in BP changes by a reduction in EBFR. Reduction in EBFR if BP falls during IDH is thus not supported. However, none of the patients experienced IDH. Further studies are required...... to evaluate the impact of changes in EBFR on BP during IDH....

  14. Fourier Analysis of Peripheral Blood Pressure and Flow in Intraoperative Assessment of Infrainguinal Arterial Reconstructions

    Directory of Open Access Journals (Sweden)

    Cheshmedzhiev Mihail V.

    2014-08-01

    Full Text Available AIM: To assess infrainguinal arterial reconstructions by intraoperative flowmetry under the distal anastomosis using a fast Fourier transformation; calculate and compare the amplitude ratios of peripheral arterial blood pressure and volume flow before and after drug-induced vasodilation of occluded bypass grafts and bypass grafts that have been patent at least for 1 year. To find what magnitude of the change of these ratios indicate a long-term patency of the bypass grafting. PATIENTS AND METHODS: We compared the results of the intraoperative flowmetry tests of 97 patients with infrainguinal arterial reconstructions. The patients were divided into two groups based on the graft status: the grafts in 49 patients were patent for at least a year, and 48 patients had failed bypass. We used a fast Fourier transform (FFT of the pressure and blood flow waves and compared the ratios of their amplitudes before and after administration of a vasodilator drug into the graft. Comparing the ratios obtained before and those after administration of the drug we quantified their change in each group and analysed them. RESULTS: After a drug-induced vasodilation, the blood pressure and flow amplitude ratios for the group with compromised reconstructions were less than 1.9 times smaller than those before drug infusion, while for the group with bypass grafts that had been functional for at least 12 months the ratios declined by more than 1.9≈2 times. CONCLUSION: The magnitude of the change of amplitude ratios of the peripheral pressure and volume flow after drug-induced vasodilation can be used to make an assessment of the bypass graft and the distal arterial segment.

  15. Age and gender related differences in aortic blood flow

    DEFF Research Database (Denmark)

    Traberg, Marie Sand; Pedersen, Mads Møller; Hemmsen, Martin Christian

    2012-01-01

    is to investigate the blood flow pat- terns within a group of healthy volunteers (4 females, 7 males) aged 23 to 76 years to identify changes and differences related to age and gender. The healthy volunteers were categorized by gender (male/female) and age (below/above 35 years). Subject-specific flow and geometry...... data were acquired using the research interface on a medical ultrasound scanner and segmentation of 3D magnetic resonance angiography respectively. The largest average diameter was among the elderly males (19.7 (± 1.33) mm) and smallest among the young females (12.4 (± 0.605) mm). The highest peak...... systolic velocity was in the young female group (1.02 (± 0.336) m/s) and lowest in the elderly male group (0.836 (± 0.127) m/s). A geometrical change with age was observed as the AA becomes more bended with age. This also affects the blood flow velocity patterns, which are markedly different from young...

  16. Three-dimensional diastolic blood flow in the left ventricle.

    Science.gov (United States)

    Khalafvand, Seyed Saeid; Ng, Eddie Yin-Kwee; Zhong, Liang; Hung, Tin-Kan

    2017-01-04

    Three-dimensional blood flow in a human left ventricle is studied via a computational analysis with magnetic resonance imaging of the cardiac motion. Formation, growth and decay of vortices during the myocardial dilation are analyzed with flow patterns on various diametric planes. They are dominated by momentum transfer during flow acceleration and deceleration through the mitral orifice. The posterior and anterior vortices form an asymmetric annular vortex at the mitral orifice, providing a smooth transition for the rapid inflow to the ventricle. The development of core vortex accommodates momentum for deceleration and for acceleration at end diastolic atrial contraction. The rate of energy dissipation and that of work done by viscous stresses are small; they are approximately balanced with each other. The kinetic energy flux and the rate of work done by pressure delivered to blood from ventricular dilation is well balanced by the total energy influx at the mitral orifice and the rate change of kinetic energy in the ventricle. Published by Elsevier Ltd.

  17. Intracoronary ghrelin infusion decreases coronary blood flow in anesthetized pigs.

    Science.gov (United States)

    Grossini, Elena; Molinari, Claudio; Mary, David A S G; Ghigo, Ezio; Bona, Gianni; Vacca, Giovanni

    2007-02-01

    The peptide ghrelin has been linked to the atherosclerotic process and coronary artery disease. We planned to study, for the first time, the primary effects of ghrelin on the intact coronary circulation and determine the mechanisms involved. In 24 sodium pentobarbitone-anesthetized pigs, changes in anterior descending coronary blood flow caused by intracoronary infusion of ghrelin at constant heart rate and arterial pressure were assessed using electromagnetic flowmeters. In 20 pigs, intracoronary infusion of ghrelin decreased coronary blood flow without affecting left ventricular maximum rate of change of left ventricular systolic pressure (dP/dt(max)), filling pressures of the heart or plasma levels of GH. In four pigs, this decrease was graded by step increments of infused dose of the hormone. The mechanisms of the above response were studied in the 20 pigs by repeating the experiment after coronary flow had returned to the control values observed before infusion. The ghrelin-induced coronary vasoconstriction was not affected by iv atropine (five pigs) or phentolamine (five pigs). This response was abolished by iv butoxamine (five pigs) and intracoronary N(omega)-nitro-l-arginine methyl ester (five pigs), even after reversing the increase in arterial pressure and coronary vascular resistance caused by the two blocking agents with iv infusion of papaverine. The present study showed that intracoronary infusion of ghrelin primarily caused coronary vasoconstriction. The mechanisms of this response were shown to involve the inhibition of a vasodilatory beta(2)-adrenergic receptor-mediated effect related to the release of nitric oxide.

  18. Design and Construct an Optical Device to Determine Relative Blood Volume in Patients Undergoing Hemodialysis

    OpenAIRE

    Dormanesh, Banafshe; Tofangchiha, Shahnaz; Abouei, Vahid; Sharifian, Hani

    2014-01-01

    Background: Occurrence of hypotension during hemodialysis in nearly 20-30% of patients, shows is the necessity of continuous monitoring the patients' blood pressure during hemodialysis. Since directly and non-invasively continuous blood pressure monitoring, is not easy, finding a parameter related to blood pressure, for indirect monitoring is of great value. Related blood volume (RBV) is one of the parameters, related to blood pressure and have a good potential to reflect the patient’s hemody...

  19. Numerical analysis of bypass model geometrical parameters influence on pulsatile blood flow

    Directory of Open Access Journals (Sweden)

    Jonášová A.

    2011-06-01

    Full Text Available The present study is focused on the analysis of pulsatile blood flow in complete idealized 3D bypass models in dependence on three main geometrical parameters (stenosis degree, junction angle and diameter ratio. Assuming the blood to be an incompressible Newtonian fluid, the non-linear system of Navier-Stokes equations is integrated in time by a fully implicit second-order accurate fractional-step method. The space discretization is performed with the help of the cell-centred finite volume method formulated for unstructured tetrahedral grids. In order to model a realistic coronary blood flow, a time-dependent flow rate taken from corresponding literature is considered. For the analysis of obtained numerical results, special emphasis is placed on their comparison in the form of velocity isolines at several selected cross-sections during systolic and diastolic phases. The remainder of this paper is devoted to discussion of walls shear stress distribution and its oscillatory character described by the oscillatory shear index with regard to areas prone to development of intimal hyperplasia or to thrombus formation.

  20. Usefulness of measurement of blood flow by RI plethysmography

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, Kenji; Ling, Qing Cheng; Mori, Yutaka; Tanaka, Uzuru; Shimada, Takao [Jikei Univ., Tokyo (Japan). School of Medicine

    1997-03-01

    We have developed the RI plethysmography, and have applied it to ordinary clinic diagnosis and the evaluation of treatment. The subjects were 58 cases (39 cases of the obstruction of the peripheral blood circulation: ASO 24 cases, TAO 4 cases and arterial sclerotic change 11 cases; the non-abnormal control was 19 cases). The clinical benefit of this method was evaluated. In the cases with 1 and 2 degrees of Fontaine`s classification and ASO and TAO, the blood flow of legs measured by our method significantly decreased in association with symptoms and angiographic findings. This method is suitable to the determination of angiography and evaluation of the effect of treatment. (author)

  1. Decreased right heart blood volume determined by magnetic resonance imaging: evidence of central underfilling in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Søndergaard, Lise; Møgelvang, J

    1995-01-01

    as the cardiac output (CO) multiplied by the central circulation time, was significantly decreased (1.47 vs. 1.81 L, P blood volume (4.43 vs. 3.64 L, P plasma volume (4.05 vs. 3.27 L, P ...Whether the central blood volume is reduced or expanded in cirrhosis is still under debate. Accordingly, the current study was undertaken to assess the volume of the heart cavities. Ten cirrhotic patients and matched controls had their right and left ventricular end-diastolic volumes (RVDV and LVDV...... mL, NS), and left atrial volume (70 vs. 57 mL, P = .08) were normal or slightly increased. The right ejection fraction (68% vs. 53%, P blood volume (CBV), assessed...

  2. Computational fluid dynamics using in vivo ultrasound blood flow measurements

    DEFF Research Database (Denmark)

    Traberg, Marie Sand; Pedersen, Mads Møller; Hemmsen, Martin Christian

    2012-01-01

    This paper presents a model environment for construction of patient-specific computational fluid dynamic (CFD) models for the abdominal aorta (AA). Realistic pulsatile velocity waveforms are employed by using in vivo ultrasound blood flow measurements. Ultrasound is suitable for acquisition....... The estimated and smoothed velocity profiles were quantitatively compared. The energy contained in the velocity profile after smoothing is 65% larger relative to the noise contaminated estimated profiles. In conclusion, a model environment that produces realistic patient-specific CFD simulation models without...

  3. Elementary wave interactions in blood flow through artery

    Science.gov (United States)

    Raja Sekhar, T.; Minhajul

    2017-10-01

    In this paper, we consider the Riemann problem and interaction of elementary waves for the quasilinear hyperbolic system of conservation laws that arises in blood flow through arteries. We study the properties of solution involving shocks and rarefaction waves and establish the existence and uniqueness conditions. We show that the Riemann problem is solvable for arbitrary initial data under certain condition and construct the condition for no-feasible solution. Finally, we present numerical examples with different initial data and discuss all possible interactions of elementary waves.

  4. Metabolic control of muscle blood flow during exercise in humans

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher

    2003-01-01

    to exert control of muscle vasodilation. Adenosine, nitric oxide (NO), prostacyclin (PGI2), and endothelial-derived hyperpolarization factor (EDHF) are possible mediators of muscle vasodilation during exercise. In humans, adenosine has been shown to contribute to functional hyperemia as blood flow...... that combined blockade of NOS and PGI2, and NOS and cytochrome P450, both attenuate exercise-induced hyperemia in humans. Combined vasodilator blockade studies offer the potential to uncover important interactions and compensatory vasodilator responses. The signaling pathways that link metabolic events evoked...

  5. Dynamics of renal blood flow autoregulation in rats

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Wagner, A J; Marsh, D J

    1991-01-01

    component most likely represents an intrinsic vascular, myogenic, mechanism. The gain maximum of the admittance in the frequency range corresponding to the autonomous tubular oscillations indicates that the dynamic characteristics responsible for the occurrence of the spontaneous tubular oscillations must......Two separate components could be resolved in tests of the dynamic autoregulation of renal blood flow. The slow component corresponds to the frequency at which spontaneous proximal tubular pressure oscillations are found, and are most likely due to the operation of the TGF. The high frequency...

  6. Validation of Blood Flow Simulations in Intracranial Aneurysms

    Science.gov (United States)

    Yu, Yue; Anor, Tomer; Baek, Hyoungsu; Jayaraman, Mahesh; Madsen, Joseph; Karniadakis, George

    2010-11-01

    Catheter-based digital subtraction angiography (DSA) is the most accurate diagnostic procedure for investigating vascular anomalies and cerebral blood flow. Here we describe utilization of DSA in a patient with an intracranial aneursysm to validate corresponding spectral element simulations. Subsequently, we examine via visualization the structure of flow in internal carotid arteries laden with three different types of aneurysms: (1) a wide-necked saccular aneurysm, (2) a narrower-necked saccular aneurysm, and (3) a case with two adjacent saccular aneurysms. We have found through high resolution simulations that in cases (1) and (3) in physiological conditions a hydrodynamic instability occurs during the decelerating systolic phase resulting in a high frequency oscillation (20-50 Hz). We use the in-silico dye visualization to discriminate among different physical mechanisms causing the instability and contrast their effect with case (2) for which an instability arises only at much higher flowrates.

  7. Skin temperature and subcutaneous adipose blood flow in man

    DEFF Research Database (Denmark)

    Astrup, A; Bülow, J; Madsen, J

    1980-01-01

    The abdominal subcutaneous adipose tissue blood flow (ATBF) was measured bilaterally by the 133Xe washout method. At one side of the skin (epicutaneous) temperature was varied with a temperature blanket, the other side served as control. There was a significant (P less than 0.001) positive...... correlation between skin temperature and ATBF. In the range from 25 to 37 degrees CATBF increased 9% of the control flow on average per centigrade increase in skin temperature. ATBF at the control side was uninfluenced by the contralateral variations in skin temperature. Although no better correlation could...... be demonstrated between ATBF and subcutaneous temperature than between ATBF and skin temperature, arguments are presented in favour of the hypothesis that ATBF is influenced by the subcutaneous temperature rather than via reflexes from the skin. Infiltration of the 133Xe depots with 20 microgram histamine...

  8. Analysis of intestinal water absorption and changes in circulating blood volume in rats.

    Science.gov (United States)

    Morita, M

    1987-01-01

    To analyze the change in blood volume after intestinal absorption, circulating blood volume was continuously monitored in rats after infusion of various solutions into the small intestine. Arterial and venous catheters were connected to a system for continuous monitoring of blood volume by the dilution method using 51Cr-labeled erythrocytes. Test solutions (tap water, 0.45, 0.9, 1.8% NaCl, 0.45% NaCl with 2% glucose, and 5% glucose) were infused at a rate of 1 ml/100 g body wt. for 10 min through a duodenal catheter. After the infusion, blood volume increased except in the 1.8% NaCl group, which showed a transient decrease in blood volume by about 10%. The rate of blood volume increase was highest in the 0.45% NaCl with 2% glucose group and lowest in the 1.8% NaCl group. The retention ratio of infused solution in the vascular space was almost identical among the groups and was about 22%. These results indicate that the rate of increase in blood volume after intestinal administration of fluid is modified by the osmolality of the fluid and Na-glucose co-transport, whereas the retention ratio of the infused fluid in blood is constant.

  9. Effects of exercise training with blood flow restriction on blood pressure in medicated hypertensive patients

    Directory of Open Access Journals (Sweden)

    Marcos Antônio Cezar

    2016-06-01

    Full Text Available Abstract The development of non-pharmacological approaches to hypertension (HA is critical for both prevention and treatment. This study examined the hemodynamic and biochemical responses of medicated hypertensive women to resistance exercise with blood flow restriction (vascular occlusion. Twenty-three women were randomly assigned to one of three groups: High intensity strength training (n = 8; low-intensity resistance exercise with occlusion (n = 8; and control (n = 7. The first two groups underwent eight weeks of training performed twice a week, including three series of wrist flexion exercises with or without vascular occlusion. The exercised with occlusion group showed pre- to post-test reduction in systolic and diastolic blood pressure, mean arterial pressure, and double product, whereas the other groups showed no significant hemodynamic changes. In conclusion, resistance exercise during 8 weeks was effective in lowering blood pressure in medicated hypertensive subjects.

  10. A Lumped-Parameter Subject-Specific Model of Blood Volume Response to Fluid Infusion

    Directory of Open Access Journals (Sweden)

    Ramin Bighamian

    2016-08-01

    Full Text Available This paper presents a lumped-parameter model that can reproduce blood volume response to fluid infusion. The model represents the fluid shift between the intravascular and interstitial compartments as the output of a hypothetical feedback controller that regulates the ratio between the volume changes in the intravascular and interstitial fluid at a target value (called target volume ratio. The model is characterized by only three parameters: the target volume ratio, feedback gain (specifying the speed of fluid shift, and initial blood volume. This model can obviate the need to incorporate complex mechanisms involved in the fluid shift in reproducing blood volume response to fluid infusion. The ability of the model to reproduce real-world blood volume response to fluid infusion was evaluated by fitting it to a series of data reported in the literature. The model reproduced the data accurately with average error and root-mean-squared error (RMSE of 0.6 % and 9.5 % across crystalloid and colloid fluids when normalized by the underlying responses. Further, the parameters derived for the model showed physiologically plausible behaviors. It was concluded that this simple model may accurately reproduce a variety of blood volume responses to fluid infusion throughout different physiological states by fitting three parameters to a given dataset. This offers a tool that can quantify the fluid shift in a dataset given the measured fractional blood volumes.

  11. A Lumped-Parameter Subject-Specific Model of Blood Volume Response to Fluid Infusion.

    Science.gov (United States)

    Bighamian, Ramin; Reisner, Andrew T; Hahn, Jin-Oh

    2016-01-01

    This paper presents a lumped-parameter model that can reproduce blood volume response to fluid infusion. The model represents the fluid shift between the intravascular and interstitial compartments as the output of a hypothetical feedback controller that regulates the ratio between the volume changes in the intravascular and interstitial fluid at a target value (called "target volume ratio"). The model is characterized by only three parameters: the target volume ratio, feedback gain (specifying the speed of fluid shift), and initial blood volume. This model can obviate the need to incorporate complex mechanisms involved in the fluid shift in reproducing blood volume response to fluid infusion. The ability of the model to reproduce real-world blood volume response to fluid infusion was evaluated by fitting it to a series of data reported in the literature. The model reproduced the data accurately with average error and root-mean-squared error (RMSE) of 0.6 and 9.5% across crystalloid and colloid fluids when normalized by the underlying responses. Further, the parameters derived for the model showed physiologically plausible behaviors. It was concluded that this simple model may accurately reproduce a variety of blood volume responses to fluid infusion throughout different physiological states by fitting three parameters to a given dataset. This offers a tool that can quantify the fluid shift in a dataset given the measured fractional blood volumes.

  12. Partitioned fluid-solid coupling for cardiovascular blood flow: left-ventricular fluid mechanics.

    Science.gov (United States)

    Krittian, Sebastian; Janoske, Uwe; Oertel, Herbert; Böhlke, Thomas

    2010-04-01

    We present a 3D code-coupling approach which has been specialized towards cardiovascular blood flow. For the first time, the prescribed geometry movement of the cardiovascular flow model KaHMo (Karlsruhe Heart Model) has been replaced by a myocardial composite model. Deformation is driven by fluid forces and myocardial response, i.e., both its contractile and constitutive behavior. Whereas the arbitrary Lagrangian-Eulerian formulation (ALE) of the Navier-Stokes equations is discretized by finite volumes (FVM), the solid mechanical finite elasticity equations are discretized by a finite element (FEM) approach. Taking advantage of specialized numerical solution strategies for non-matching fluid and solid domain meshes, an iterative data-exchange guarantees the interface equilibrium of the underlying governing equations. The focus of this work is on left-ventricular fluid-structure interaction based on patient-specific magnetic resonance imaging datasets. Multi-physical phenomena are described by temporal visualization and characteristic FSI numbers. The results gained show flow patterns that are in good agreement with previous observations. A deeper understanding of cavity deformation, blood flow, and their vital interaction can help to improve surgical treatment and clinical therapy planning.

  13. Sleep apnea termination decreases cerebral blood volume: a near-infrared spectroscopy case study

    Science.gov (United States)

    Virtanen, Jaakko; Noponen, Tommi; Salmi, Tapani; Toppila, Jussi; Meriläinen, Pekka

    2009-07-01

    Medical near-infrared spectroscopy (NIRS) can be used to estimate cerebral haemodynamic changes non-invasively. Sleep apnea is a common sleep disorder where repetitive pauses in breathing decrease the quality of sleep and exposes the individual to various health problems. We have measured oxygenated and deoxygenated haemoglobin concentration changes during apneic events in sleep from the forehead of one subject using NIRS and used principal component analysis to extract extracerebral and cortical haemodynamic changes from NIRS signals. Comparison of NIRS signals with EEG, bioimpedance, and pulse oximetry data suggests that termination of apnea leads to decreases in cerebral blood volume and flow that may be related to neurological arousal via neurovascular coupling.

  14. Blood volume distribution in patients with cirrhosis: aspects of the dual-head gamma-camera technique

    DEFF Research Database (Denmark)

    Kiszka-Kanowitz, M; Henriksen, Jens Henrik Sahl; Møller, Søren

    2001-01-01

    BACKGROUND/AIMS: Patients with cirrhosis have increased total blood volume (TBV). The size of the "effective" blood volume has been closely investigated, whereas the distribution of the blood volume outside the thorax has not been examined. The aim was to estimate the blood volume distribution......: The close relation between the estimated blood volume in the thorax region and the central and arterial blood volume, obtained by the dynamic indicator dilution technique (r=0.87, Pblood volume distribution in the cirrhotic...... patients with increased splanchnic blood volume (SpBV: 25.0 vs. 18.2% of TBV in controls, Ppressure gradient above 12 mmHg had SpBV above 20% of TBV, but the blood volumes in the liver region were similar. CONCLUSIONS: DHGCT is a valid method...

  15. Biology and Mechanics of Blood Flows Part II: Mechanics and Medical Aspects

    CERN Document Server

    Thiriet, Marc

    2008-01-01

    Biology and Mechanics of Blood Flows presents the basic knowledge and state-of-the-art techniques necessary to carry out investigations of the cardiovascular system using modeling and simulation. Part II of this two-volume sequence, Mechanics and Medical Aspects, refers to the extraction of input data at the macroscopic scale for modeling the cardiovascular system, and complements Part I, which focuses on nanoscopic and microscopic components and processes. This volume contains chapters on anatomy, physiology, continuum mechanics, as well as pathological changes in the vasculature walls including the heart and their treatments. Methods of numerical simulations are given and illustrated in particular by application to wall diseases. This authoritative book will appeal to any biologist, chemist, physicist, or applied mathematician interested in the functioning of the cardiovascular system.

  16. [Imaging Blood Flow and Pulsation of Retinal Vessels with Full-Field Swept-Source OCT].

    Science.gov (United States)

    Spahr, H; Hillmann, D; Hain, C; Pfäffle, C; Sudkamp, H; Franke, G; Koch, P; Hüttmann, G

    2016-12-01

    Optical coherence tomography (OCT) uses interference to image the retina with high axial resolution. In the last 25 years, new technologies have permitted a steady increase in imaging speed, which made it possible to enlarge the imaged field and to avoid motion artefacts. The speed and precision of retinal imaging is now limited by photodamage of the retina caused by the focused OCT beam and by the speed of the scanning mechanics. Full-field swept-source (FF-SS)-OCT decreases irradiance on the retina and dispenses moving parts by using a camera to acquire the full volume of the retina in parallel. Here we show that FF-SS-OCT is rapid and precise enough to image pulsation in the retina induced by the heart beat. Series of OCT volumes 1.8 × 0.7 mm wide and 1.8 mm deep were recorded in young volunteers over a few cycles of the heart beat. Morphology of the retinal vessels, blood flow and tissue motion as caused by vessel pulsation were calculated from the OCT data. FF-SS-OCT was able to visualise the main structures of the neuronal retina, including vessels and small capillaries and without any motion artefacts. Information on three different dynamic processes was obtained from only one recorded series of OCT volumes: pulsation of blood flow and blood pressure in retinal vessels as well as pulsation of the choroid. Delays between arterial and venous pulse and delay between pulsation in retinal and choroidal vessels were calculated. With a time resolution of 0.5 ms, FF-SS-OCT is able to visualise previously unmeasurably fast changes in the retina, including the propagation of pulse waves. Georg Thieme Verlag KG Stuttgart · New York.

  17. Cerebral blood flow and intracranial pulsatility studied with MRI: measurement, physiological and pathophysiological aspects

    Energy Technology Data Exchange (ETDEWEB)

    Waahlin, Anders

    2012-07-01

    During each cardiac cycle pulsatile arterial blood inflates the vascular bed of the brain, forcing cerebrospinal fluid (CSF) and venous blood out of the cranium. Excessive arterial pulsatility may be part of a harmful mechanism causing cognitive decline among elderly. Additionally, restricted venous flow from the brain is suggested as the cause of multiple sclerosis. Addressing hypotheses derived from these observations requires accurate and reliable investigational methods. This work focused on assessing the pulsatile waveform of cerebral arterial, venous and CSF flows. The overall aim of this dissertation was to explore cerebral blood flow and intracranial pulsatility using MRI, with respect to measurement, physiological and pathophysiological aspects.Two-dimensional phase contrast magnetic resonance imaging (2D PCMRI) was used to assess the pulsatile waveforms of cerebral arterial, venous and CSF flow. The repeatability was assessed in healthy young subjects. The 2D PCMRI measurements of cerebral arterial, venous and CSF pulsatility were generally repeatable but the pulsatility decreased systematically during the investigation. A method combining 2D PCMRI measurements with invasive CSF infusion tests to determine the magnitude and distribution of compliance within the craniospinal system was developed and applied in a group of healthy elderly. The intracranial space contained approximately two thirds of the total craniospinal compliance. The magnitude of craniospinal compliance was less than suggested in previous studies. The vascular hypothesis for multiple sclerosis was tested. Venous drainage in the internal jugular veins was compared between healthy controls and multiple sclerosis patients using 2D PCMRI. For both groups, a great variability in the internal jugular flow was observed but no pattern specific to multiple sclerosis could be found. Relationships between regional brain volumes and potential biomarkers of intracranial cardiac-related pulsatile

  18. The relationship between cerebral blood flow and volume in humans

    DEFF Research Database (Denmark)

    Rostrup, Egill; Knudsen, Gitte M; Law, Ian

    2005-01-01

    The purpose of this study was to establish the relationship between regional CBF and CBV at normal, resting cerebral metabolic rates. Eleven healthy volunteers were investigated with PET during baseline conditions, and during hyper- and hypocapnia. Values for rCBF and rCBV were obtained using (15...

  19. The relationship between cerebral blood flow and volume in humans

    DEFF Research Database (Denmark)

    Rostrup, Egill; Knudsen, Gitte M; Law, Ian

    2005-01-01

    intersubject variability, the goodness of fit for linear and nonlinear models were not significantly different. The results of the study are applied to a numerical estimation of regional brain deoxy-haemoglobin content. Independently of the choice of model for the rCBV vs. rCBF relationship, a nonlinear deoxy...

  20. Postural hypocapnic hyperventilation is associated with enhanced peripheral vasoconstriction in postural tachycardia syndrome with normal supine blood flow

    Science.gov (United States)

    Stewart, Julian M.; Medow, Marvin S.; Cherniack, Neil S.; Natelson, Benjamin H.

    2015-01-01

    Previous investigations have demonstrated a subset of postural tachycardia syndrome (POTS) patients characterized by normal peripheral resistance and blood volume while supine but thoracic hypovolemia and splanchnic blood pooling while upright secondary to splanchnic hyperemia. Such “normal-flow” POTS patients often demonstrate hypocapnia during orthostatic stress. We studied 20 POTS patients (14–23 yr of age) and compared them with 10 comparably aged healthy volunteers. We measured changes in heart rate, blood pressure, heart rate and blood pressure variability, arm and leg strain-gauge occlusion plethysmography, respiratory impedance plethysmography calibrated against pneumotachography, end-tidal partial pressure of carbon dioxide (PetCO2), and impedance plethysmographic indexes of blood volume and blood flow within the thoracic, splanchnic, pelvic (upper leg), and lower leg regional circulations while supine and during upright tilt to 70°. Ten POTS patients demonstrated significant hyperventilation and hypocapnia (POTSHC) while 10 were normocapnic with minimal increase in postural ventilation, comparable to control. While relative splanchnic hypervolemia and hyperemia occurred in both POTS groups compared with controls, marked enhancement in peripheral vasoconstriction occurred only in POTSHC and was related to thoracic blood flow. Variability indexes suggested enhanced sympathetic activation in POTSHC compared with other subjects. The data suggest enhanced cardiac and peripheral sympathetic excitation in POTSHC. PMID:16565300

  1. [Pulmonary blood flow distribution in acute viral bronchiolitis].

    Science.gov (United States)

    Carvalho, Paulo R A; Cunha, Renato D; Barreto, Sérgio S Menna

    2002-01-01

    To assess lung perfusion patterns in inpatients with acute viral bronchiolitis using quantitative 99mTc-MAA scintigraphy so as to establish an association with clinical and radiological findings. A comparative, prospective case series study with a focus on diagnosis was carried out in a population of patients with acute viral bronchiolitis admitted to Hospital de Clínicas de Porto Alegre. Inclusion criteria were age between 1 and 24 months and first sudden-onset wheezing episode, suggesting bronchiolitis. The patients in the study were submitted to clinical, radiological and 99mTc-MAA lung perfusion evaluation during the first 24 hours of admission. Statistical analysis employed t test, taking into consideration a significance level of 0.05. The regional distribution of lung blood flow in the 38 patients studied was more pronounced in the upper section of the left lung in relation to the right lung (P1.0 in the upper and middle sections of both lungs. In the lower section it was >1.0 only in the right lung (Pbronchiolitis; only a tendency to redirect lung blood flow towards upper lung sections was observed.

  2. Alterations of Regional Cerebral Blood Flow in Major Depressive Disorder

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Hyoung; Chung, Yong An; Seo, Ye Young; Yoo, Ik Dong; Na, Sae Jung; Jung, Hyun Suk; Kim, Ki Jun [College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2009-04-15

    The authors analyzed how the regional cerebral blood flow (rCBF) findings of patients with major depression differ from the normal control, and our results were compared to previous reports. Twelve patients fulfilling DSM-IV criteria for major depression who were off all psychotropic medications for > 4 weeks (male: 7, female: 5, age range: 19approx52 years, average age: 29.3+-9.9 years) and 14 normal volunteers (male: 8, female: 6, age range: 19approx53 years, average age: 31.4+-9.2 years) were recruited. Images of brain perfusion SPECT were obtained using Tc-99m ECD and patterns of the rCBF were compared between patients with major depression and the healthy control subjects. The patients with major depression showed increase of the r-CBF in right lingual gyrus, right fusiform gyrus, left lingual gyrus, left precuneus, and left superior temporal gyrus, and showed decrease of r-CBF in right pons, left medial frontal gyrus, cingulate gyrus of left limbic lobe, cingulate gyrus of right frontal lobe, and cingulate gyrus of right limbic lobe compared to the normal control. The Tc-99m ECD brain perfusion SPECT findings in our study did not differ from the previously reported regional cerebral blood flow pattern of patients with major depression. Especially, decreased rCBF pattern typical to major depression patients in the right pons, left medial frontal gyrus, and cingulate regions was clearly demonstrated

  3. History of International Society for Cerebral Blood Flow and Metabolism.

    Science.gov (United States)

    Paulson, Olaf B; Kanno, Iwao; Reivich, Martin; Sokoloff, Louis

    2012-07-01

    Interest in the brain's circulation dates back more than a century and has been steadily growing. Quantitative methods for measurements of cerebral blood flow (CBF) and energy metabolism became available in the middle of the 20th century and gave a new boost to the research. Scientific meetings dealing with CBF and metabolism were arranged, and the fast growing research led to a demand for a specialized journal. In this scientific environment, the International Society for Cerebral Blood Flow and Metabolism (ISCBFM) and its official Journal of Cerebral Metabolism were established in 1981 and has since then been a major success. The development of new brain imaging methods has had a major impact. Regulation of CBF and ischemia has been the main topics at the meetings. A new field of brain mapping research emerged and has now its own society and meetings. Brain emission tomography research has grown within the society and is now an integrated part. The ISCBFM is a sound society, and support of young scientists is among its goals. Several awards have been established. Other activities including summer schools, courses, satellite meetings, and Gordon conferences have contributed to the success of the society and strengthened the research.

  4. Monitoring blood flow and photobleaching during topical ALA PDT treatment

    Science.gov (United States)

    Sands, Theresa L.; Sunar, Ulas; Foster, Thomas H.; Oseroff, Allan R.

    2009-02-01

    Photodynamic therapy (PDT) using topical aminolevulinic acid (ALA) is currently used as a clinical treatment for nonmelanoma skin cancers. In order to optimize PDT treatment, vascular shutdown early in treatment must be identified and prevented. This is especially important for topical ALA PDT where vascular shutdown is only temporary and is not a primary method of cell death. Shutdown in vasculature would limit the delivery of oxygen which is necessary for effective PDT treatment. Diffuse correlation spectroscopy (DCS) was used to monitor relative blood flow changes in Balb/C mice undergoing PDT at fluence rates of 10mW/cm2 and 75mW/cm2 for colon-26 tumors implanted intradermally. DCS is a preferable method to monitor the blood flow during PDT of lesions due to its ability to be used noninvasively throughout treatment, returning data from differing depths of tissue. Photobleaching of the photosensitizer was also monitored during treatment as an indirect manner of monitoring singlet oxygen production. In this paper, we show the conditions that cause vascular shutdown in our tumor model and its effects on the photobleaching rate.

  5. Adipose tissue and skeletal muscle blood flow during mental stress

    Energy Technology Data Exchange (ETDEWEB)

    Linde, B.; Hjemdahl, P.; Freyschuss, U.; Juhlin-Dannfelt, A.

    1989-01-01

    Mental stress (a modified Stroop color word conflict test (CWT)) increased adipose tissue blood flow (ATBF; 133Xe clearance) by 70% and reduced adipose tissue vascular resistance (ATR) by 25% in healthy male volunteers. The vasculatures of adipose tissue (abdomen as well as thigh), skeletal muscle of the calf (133Xe clearance), and the entire calf (venous occlusion plethysmography) responded similarly. Arterial epinephrine (Epi) and glycerol levels were approximately doubled by stress. Beta-Blockade by metoprolol (beta 1-selective) or propranolol (nonselective) attenuated CWT-induced tachycardia similarly. Metoprolol attenuated stress-induced vasodilation in the calf and tended to do so in adipose tissue. Propranolol abolished vasodilation in the calf and resulted in vasoconstriction during CWT in adipose tissue. Decreases in ATR, but not in skeletal muscle or calf vascular resistances, were correlated to increases in arterial plasma glycerol (r = -0.42, P less than 0.05), whereas decreases in skeletal muscle and calf vascular resistances, but not in ATR, were correlated to increases in arterial Epi levels (r = -0.69, P less than 0.01; and r = -0.43, P less than 0.05, respectively). The results suggest that mental stress increases nutritive blood flow in adipose tissue and skeletal muscle considerably, both through the elevation of perfusion pressure and via vasodilatation. Withdrawal of vasoconstrictor nerve activity, vascular beta 2-adrenoceptor stimulation by circulating Epi, and metabolic mechanisms (in adipose tissue) may contribute to the vasodilatation.

  6. Multiscale modeling and simulation of brain blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Perdikaris, Paris, E-mail: parisp@mit.edu [Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Grinberg, Leopold, E-mail: leopoldgrinberg@us.ibm.com [IBM T.J Watson Research Center, 1 Rogers St, Cambridge, Massachusetts 02142 (United States); Karniadakis, George Em, E-mail: george-karniadakis@brown.edu [Division of Applied Mathematics, Brown University, Providence, Rhode Island 02912 (United States)

    2016-02-15

    The aim of this work is to present an overview of recent advances in multi-scale modeling of brain blood flow. In particular, we present some approaches that enable the in silico study of multi-scale and multi-physics phenomena in the cerebral vasculature. We discuss the formulation of continuum and atomistic modeling approaches, present a consistent framework for their concurrent coupling, and list some of the challenges that one needs to overcome in achieving a seamless and scalable integration of heterogeneous numerical solvers. The effectiveness of the proposed framework is demonstrated in a realistic case involving modeling the thrombus formation process taking place on the wall of a patient-specific cerebral aneurysm. This highlights the ability of multi-scale algorithms to resolve important biophysical processes that span several spatial and temporal scales, potentially yielding new insight into the key aspects of brain blood flow in health and disease. Finally, we discuss open questions in multi-scale modeling and emerging topics of future research.

  7. Thrombospondin 1 and Vasoactive Agents Indirectly Alter Tumor Blood Flow

    Directory of Open Access Journals (Sweden)

    Jeff S. Isenberg

    2008-08-01

    Full Text Available Nitric oxide (NO plays important physiological roles in the vasculature to regulate angiogenesis, blood flow, and hemostasis. In solid tumors, NO is generally acknowledged to mediate angiogenic responses to several growth factors. This contrasts with conflicting evidence that NO can acutely increase tumor perfusion through local vasodilation or diminish perfusion by preferential relaxation of peripheral vascular beds outside the tumor. Because thrombospondin 1 (TSP1 is an important physiological antagonist of NO in vascular cells, we examined whether, in addition to inhibiting tumor angiogenesis, TSP1 can acutely regulate tumor blood flow. We assessed this activity of TSP1 in the context of perfusion responses to NO as a vasodilator and epinephrine as a vasoconstrictor. Nitric oxide treatment of wild type and TSP1 null mice decreased perfusion of a syngeneic melanoma, whereas epinephrine transiently increased tumor perfusion. Acute vasoactive responses were also independent of the level of tumor-expressed TSP1 in a melanoma xenograft, but recovery of basal perfusion was modulated by TSP1 expression. In contrast, overexpression of truncated TSP1 lacking part of its CD47 binding domain lacked this modulating activity. These data indicate that TSP1 primarily regulates long-term vascular responses in tumors, in part, because the tumor vasculature has a limited capacity to acutely respond to vasoactive agents.

  8. Clustering of microscopic particles in constricted blood flow

    Science.gov (United States)

    Bächer, Christian; Schrack, Lukas; Gekle, Stephan

    2017-01-01

    A mixed suspension of red blood cells (RBCs) and microparticles flows through a cylindrical channel with a constriction mimicking a stenosed blood vessel. Our three-dimensional Lattice-Boltzmann simulations show that the RBCs are depleted right ahead of and after the constriction. Although the RBC mean concentration (hematocrit) is 16.5% or 23.7%, their axial concentration profile is very similar to that of isolated tracer particles flowing along the central axis. Most importantly, however, we find that the stiff microparticles exhibit the opposite behavior. Arriving on a marginated position near the channel wall, they can pass through the constriction only if they find a suitable gap to dip into the dense plug of RBCs occupying the channel center. This leads to a prolonged dwell time and, as a consequence, to a pronounced increase in microparticle concentration right in front of the constriction. For biochemically active particles such as drug delivery agents or activated platelets this clustering may have important physiological consequences, e.g., for the formation of microthrombi.

  9. Screening for ochratoxin A in blood by flow injection analysis.

    Science.gov (United States)

    Hult, K; Fuchs, R; Peraica, M; Plestina, R; Ceović, S

    1984-12-01

    A micromethod for ochratoxin A detection in human sera by flow injection technique is described. The method requires 50 microliter of sera, and it is designed to distinguish samples containing less than 10 ng ochratoxin A per ml. The method is based on fluorescence measurement following a simple extraction procedure for which very small amounts of chemicals are needed. Since the method is not confirmatory, all samples showing fluorescence above a certain intensity have to be reanalysed with some other method where a confirmation step in included. Because of the small amount of serum needed and the rapid procedure (less than 15 min), a large number of samples can be analysed very quickly. The method may therefore be applicable for large screening campaigns conducted to determine the presence of ochratoxin A in blood. This conclusion is based on 1675 samples and 147 standards analysed concurrently by the flow injection technique and an earlier published enzymic method. The method is also suitable for monitoring ochratoxin A levels in the blood of experimental animals.

  10. Integrated Lateral Flow Device for Flow Control with Blood Separation and Biosensing

    Directory of Open Access Journals (Sweden)

    Veronica Betancur

    2017-12-01

    Full Text Available Lateral flow devices are versatile and serve a wide variety of purposes, including medical, agricultural, environmental, and military applications. Yet, the most promising opportunities of these devices for diagnosis might reside in point-of-care (POC applications. Disposable paper-based lateral flow strips have been of particular interest, because they utilize low-cost materials and do not require expensive fabrication instruments. However, there are constraints on tuning flow rates and immunoassays functionalization in papers, as well as technical challenges in sensors’ integration and concentration units for low-abundant molecular detection. In the present work, we demonstrated an integrated lateral flow device that applied the capillary forces with functionalized polymer-based microfluidics as a strategy to realize a portable, simplified, and self-powered lateral flow device (LFD. The polydimethylsiloxane (PDMS surface was rendered hydrophilic via functionalization with different concentrations of Pluronic F127. Controlled flow is a key variable for immunoassay-based applications for providing enough time for protein binding to antibodies. The flow rate of the integrated LFD was regulated by the combination of multiple factors, including Pluronic F127 functionalized surface properties and surface treatments of microchannels, resistance of the integrated flow resistor, the dimensions of the microstructures and the spacing between them in the capillary pump, the contact angles, and viscosity of the fluids. Various plasma flow rates were regulated and achieved in the whole device. The LFD combined the ability to separate high quality plasma from human whole blood by using a highly asymmetric plasma separation membrane, and created controlled and steady fluid flow using capillary forces produced by the interfacial tensions. Biomarker immunoglobulin G (IgG detection from plasma was demonstrated with a graphene nanoelectronic sensor integrated

  11. Vasopressin-induced changes in splanchnic blood flow and hepatic and portal venous pressures in liver resection.

    Science.gov (United States)

    Bown, L Sand; Ricksten, S-E; Houltz, E; Einarsson, H; Söndergaard, S; Rizell, M; Lundin, S

    2016-05-01

    To minimize blood loss during hepatic surgery, various methods are used to reduce pressure and flow within the hepato-splanchnic circulation. In this study, the effect of low- to moderate doses of vasopressin, a potent splanchnic vasoconstrictor, on changes in portal and hepatic venous pressures and splanchnic and hepato-splanchnic blood flows were assessed in elective liver resection surgery. Twelve patients were studied. Cardiac output (CO), stroke volume (SV), mean arterial (MAP), central venous (CVP), portal venous (PVP) and hepatic venous pressures (HVP) were measured, intraoperatively, at baseline and during vasopressin infusion at two infusion rates (2.4 and 4.8 U/h). From arterial and venous blood gases, the portal (splanchnic) and hepato-splanchnic blood flow changes were calculated, using Fick's equation. CO, SV, MAP and CVP increased slightly, but significantly, while systemic vascular resistance and heart rate remained unchanged at the highest infusion rate of vasopressin. PVP was not affected by vasopressin, while HVP increased slightly. Vasopressin infusion at 2.4 and 4.8 U/h reduced portal blood flow (-26% and -37%, respectively) and to a lesser extent hepato-splanchnic blood flow (-9% and -14%, respectively). The arterial-portal vein lactate gradient was not significantly affected by vasopressin. Postoperative serum creatinine was not affected by vasopressin. Short-term low to moderate infusion rates of vasopressin induced a splanchnic vasoconstriction without metabolic signs of splanchnic hypoperfusion or subsequent renal impairment. Vasopressin caused a centralization of blood volume and increased cardiac output. Vasopressin does not lower portal or hepatic venous pressures in this clinical setting. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  12. Massage impairs postexercise muscle blood flow and "lactic acid" removal.

    Science.gov (United States)

    Wiltshire, E Victoria; Poitras, Veronica; Pak, Melissa; Hong, Terence; Rayner, Jay; Tschakovsky, Michael E

    2010-06-01

    This study tested the hypothesis that one of the ways sports massage aids muscle recovery from exercise is by increasing muscle blood flow to improve "lactic acid" removal. Twelve subjects performed 2 min of strenuous isometric handgrip (IHG) exercise at 40% maximum voluntary contraction to elevate forearm muscle lactic acid. Forearm blood flow (FBF; Doppler and Echo ultrasound of the brachial artery) and deep venous forearm blood lactate and H+ concentration ([La-], [H+]) were measured every minute for 10 min post-IHG under three conditions: passive (passive rest), active (rhythmic exercise at 10% maximum voluntary contraction), and massage (effleurage and pétrissage). Arterialized [La-] and [H+] from a superficial heated hand vein was measured at baseline. Data are presented as mean +/- SE. Venoarterial [La-] difference ([La-]v-a) at 30 s of post-IHG was the same across conditions (passive = 6.1 +/- 0.6 mmol x L(-1), active = 5.7 +/- 0.6 mmol x L(-1), massage = 5.5 +/- 0.6 mmol x L(-1), NS), whereas FBF was greater in passive (766 +/- 101 mL x min(-1)) versus active (614 +/- 62 mL x min(-1), P = 0.003) versus massage (540 +/- 60 mL x min(-1), P < 0.0001). Total FBF area under the curve (AUC) for 10 min after handgrip was significantly higher in passive versus massage (4203 +/- 531 vs 3178 +/- 304 mL, P = 0.024) but not versus active (3584 +/- 284 mL, P = 0.217). La(-)- efflux (FBF x [La-]v-a) AUC mirrored FBF AUC (passive = 20.5 +/- 2.8 mmol vs massage = 14.7 +/- 1.6 mmol, P = 0.03, vs active = 15.4 +/- 1.9 mmol, P = 0.064). H+ efflux (FBF x [H+]v-a) was greater in passive versus massage at 30 s (2.2 +/- 0.4e(-5) vs 1.3 +/- 0.2e(-5) mmol, P < 0.001) and 1.5 min (1.0 +/- 0.2e(-5) vs 0.6 +/- 0.09e(-5) mmol, P = 0.003) after IHG. Massage impairs La(-) and H+ removal from muscle after strenuous exercise by mechanically impeding blood flow.

  13. Blood pressure and vascular dysfunction underlie elevated cerebral blood flow in systemic lupus erythematosus.

    Science.gov (United States)

    Gasparovic, Charles; Qualls, Clifford; Greene, Ernest R; Sibbitt, Wilmer L; Roldan, Carlos A

    2012-04-01

    In previous studies cerebral blood flow (CBF) was found to be altered in patients with systemic lupus erythematosus (SLE) compared to controls. We investigated the relationships between CBF and clinical data from subjects with SLE with the aim of determining the pathologic factors underlying altered CBF in SLE. A total of 42 SLE subjects and 19 age- and sex-matched healthy control subjects were studied. Dynamic susceptibility contrast (DSC) magnetic resonance imaging (MRI) was used to measure CBF. Patients and controls underwent complete clinical and laboratory evaluations in close proximity with their MRI studies. A higher CBF was present in the SLE group and was independently associated in statistical models with higher systolic blood pressure (SBP; p blood pressure, diastolic blood pressure, or blood levels of tissue plasminogen activator in the SLE group was significantly blunted relative to the control group. These findings are consistent with an underlying cerebral hyperperfusion in SLE induced by elevated but nonhypertensive levels of SBP. The factors underlying this relationship may be functional and/or structural (atherosclerotic, thrombotic, thromboembolic, or vasculitic) cerebrovascular disease.

  14. Relationship between retinal blood flow and arterial oxygen.

    Science.gov (United States)

    Cheng, Richard W; Yusof, Firdaus; Tsui, Edmund; Jong, Monica; Duffin, James; Flanagan, John G; Fisher, Joseph A; Hudson, Chris

    2016-02-01

    Vascular reactivity, the response of the vessels to a vasoactive stimulus such as hypoxia and hyperoxia, can be used to assess the vascular range of adjustment in which the vessels are able to compensate for changes in PO2. Previous studies in the retina have not accurately quantified retinal vascular responses and precisely targeted multiple PaO2 stimuli at the same time as controlling the level of carbon dioxide, thus precluding them from modelling the relationship between retinal blood flow and oxygen. The present study modelled the relationship between retinal blood flow and PaO2, showing them to be a combined linear and hyperbolic function. This model demonstrates that the resting tonus of the vessels is at the mid-point and that they have great vascular range of adjustment, compensating for decreases in oxygen above a PETCO2 of 32-37 mmHg but being limited below this threshold. Retinal blood flow (RBF) increases in response to a reduction in oxygen (hypoxia) but decreases in response to increased oxygen (hyperoxia). However, the relationship between blood flow and the arterial partial pressure of oxygen has not been quantified and modelled in the retina, particularly in the vascular reserve and resting tonus of the vessels. The present study aimed to determine the limitations of the retinal vasculature by modelling the relationship between RBF and oxygen. Retinal vascular responses were measured in 13 subjects for eight different blood gas conditions, with the end-tidal partial pressure of oxygen (PETCO2) ranging from 40-500 mmHg. Retinal vascular response measurements were repeated twice; using the Canon laser blood flowmeter (Canon Inc., Tokyo, Japan) during the first visit and using Doppler spectral domain optical coherence tomography during the second visit. We determined that the relationship between RBF and PaO2 can be modelled as a combination of hyperbolic and linear functions. We concluded that RBF compensated for decreases in arterial oxygen content

  15. Evaluated Conjunctival Blood Flow Velocity in Daily Contact Lens Wearers.

    Science.gov (United States)

    Shi, Yingying; Hu, Liang; Chen, Wan; Qu, Dongyi; Jiang, Hong; Wang, Jianhua

    2017-04-13

    This study examined conjunctival microvasculature development in long-term habitual contact lens (HCL) wearers after a night of sleep. Twenty HCL wearers (15 women and 5 men, aged 28.6±6.9 years, mean age±standard deviation) who had worn contact lenses on a daily basis for at least 3 years and 40 noncontact lens (NCL) wearers (23 women and 17 men, aged 36.5±6.6 years, mean age±standard deviation) participated in the study. A functional slitlamp biomicroscopy imaging system was used to image the temporal bulbar conjunctiva. Imaging was performed in the morning while the contact lens wearers were not wearing their lenses after a night of sleep. The conjunctival vessel diameters, blood flow velocities, and flow rates were measured. In addition, fractal analyses were performed to obtain the vessel network density (Dbox) and complexity (D0). The average blood flow velocity in HCL wearers after a night of sleep was 0.59±0.19 mm/s, which was significantly higher than that in NCL wearers (0.48±0.17 mm/s, P<0.05). The microvessel network density and complexity levels (Dbox=1.64±0.05 and D0=1.71±0.05, respectively) in the HCL wearers were significantly higher than those in NCL wearers (Dbox=1.61±0.05 and D0=1.69±0.04, both P<0.05). The blood flow velocity was positively correlated with the duration of contact lens wear (r=0.46, P<0.05) and with the daily number of lens-wearing hours (r=0.49, P<0.05) in HCL wearers. This study identified microvascular alterations in the conjunctiva in response to daily contact lens wear after a night of sleep in long-term daily contact lens wearers. The unrecovered changes may indicate that para-inflammation occurs on ocular surfaces because of contact lens wear and that overnight sleeping with no lenses may not sufficiently restore the ocular surface to an intact state.

  16. The continuous high-precision measurement of the density of flowing blood.

    Science.gov (United States)

    Kenner, T; Leopold, H; Hinghofer-Szalkay, H

    1977-07-29

    The "mechanical oscillator" technique for the measurement of the density of fluids is based on the influence of mass on the natural frequency of a mechanical oscillator. The practical application of this principle was worked out by Kratky et al. (1969) and Leopold (1970). It is demonstrated in this study that the method permits the continuous high-precision measurement of the density of flowing blood in anesthetized animals. The accuracy is 10(5) g/ml, the maximum sampling rate 20/min. As found in rabbits and cats during the control state, physiological blood density changes related to spontaneous blood pressure variations are up to 2-10(4) g/ml. The method can be combined with i.v. injections of isotonic and iso-oncotic solutions to determine cardiac output and blood volume on the basis of a "density dilution" principle. Since the density of the interstitial fluid is lower than that of blood, fluid shifts through the capillary walls can be detected. The effects of hypertonic glucose and of hyperoncotic dextran have been examined. Changes in the density of the arterial blood appear within 10 s after i.v. injection of these fluids. Similarly, density changes result from hemorrhage and reinfusion. During and after i.v. administration of vasoactive drugs (noradrenaline, angiotensin II, acetylcholine), marked transient changes in blood density are seen which obviously reflect the effects of fluid shifts through the capillary walls. During hemorrhagic hypotension we found periodic variations in the blood density synchronous with spontaneously occurring Mayer waves. The new method seems to be a promising tool for investigations physiological and pathological capillary fluid dynamics.

  17. A Lumped-Parameter Subject-Specific Model of Blood Volume Response to Fluid Infusion

    OpenAIRE

    Ramin Bighamian; Andrew Reisner; Jin-Oh Hahn

    2016-01-01

    This paper presents a lumped-parameter model that can reproduce blood volume response to fluid infusion. The model represents the fluid shift between the intravascular and interstitial compartments as the output of a hypothetical feedback controller that regulates the ratio between the volume changes in the intravascular and interstitial fluid at a target value (called target volume ratio). The model is characterized by only three parameters: the target volume ratio, feedback gain (specifyi...

  18. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, Flemming; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... of albumin in arterial and venous blood in seven healthy subjects before and during insulin-induced hypoglycaemia. In both vascular sites blood 51Cr content and the haematocrit increased, plasma volume and intravascular albumin content decreased and the transcapillary escape rate of albumin increased during...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...

  19. Blood pressure and blood flow variation during postural change from sitting to standing: model development and validation

    DEFF Research Database (Denmark)

    Olufsen, M.S.; Ottesen, Johnny T.; Tran, H.T.

    2005-01-01

    dynamic changes in beat-to-beat arterial blood pressure and middle cerebral artery blood flow velocity during postural change from sitting to standing. Our cardiovascular model utilizes 11 compartments to describe blood pressure, blood flow, compliance, and resistance in the heart and systemic circulation....... To include dynamics due to the pulsatile nature of blood pressure and blood flow, resistances in the large systemic arteries are modeled using nonlinear functions of pressure. A physiologically based submodel is used to describe effects of gravity on venous blood pooling during postural change. Two types...... of control mechanisms are included: 1) autonomic regulation mediated by sympathetic and parasympathetic responses, which affect heart rate, cardiac contractility, resistance, and compliance, and 2) autoregulation mediated by responses to local changes in myogenic tone, metabolic demand, and CO2 concentration...

  20. Measurement of retinal blood flow rate in diabetic rats: disparity between techniques due to redistribution of flow.

    Science.gov (United States)

    Leskova, Wendy; Watts, Megan N; Carter, Patsy R; Eshaq, Randa S; Harris, Norman R

    2013-04-26

    Reports of altered retinal blood flow in experimental models of type I diabetes have provided contrasting results, which leads to some confusion as to whether flow is increased or decreased. The purpose of our study was to evaluate early diabetes-induced changes in retinal blood flow in diabetic rats, using two distinctly different methods. Diabetes was induced by injection of streptozotocin (STZ), and retinal blood flow rate was measured under anesthesia by a microsphere infusion technique, or by an index of flow based on the mean circulation time between arterioles and venules. Measurements in STZ rats were compared to age-matched nondiabetic controls. In addition, the retinal distribution of fluorescently-labeled red blood cells (RBCs) was viewed by confocal microscopy in excised flat mounts. Retinal blood flow rate was found to decrease by approximately 33% in the STZ rats compared to controls (P contrast, the mean circulation time through the retina was found to be almost 3× faster in the STZ rats (P < 0.01). This contradiction could be explained by flow redistribution through the superficial vessels of the diabetic retina, with this possibility supported by our observation of significantly fewer RBCs flowing through the deeper capillaries. We conclude that retinal blood flow rate is reduced significantly in the diabetic rat, with a substantial decrease of flow through the capillaries due to shunting of blood through the superficial layer, allowing rapid transit from arterioles to venules.

  1. Effect of Stress-free Therapy on Cerebral Blood Flow: Comparisons among patients with metabolic cardiovascular disease, healthy subjects and placebo-treated subjects

    Science.gov (United States)

    Ryotokuji, Kenji; Ishimaru, Keisou; Kihara, Kazuhiko; Namiki, Yoshihisa; Nakashima, Takuma; Otani, Satoru

    2014-01-01

    Background and aims: We have developed a Stress-free Therapy® device wherein “Pinpoint Plantar Long-wavelength Infrared Light Irradiation (PP-LILI)” increases peripheral-deep body temperature and blood flow volume and stabilizes blood pressure as well as significantly reduces stress hormones such as adrenocorticotrophic hormone and cortisol without using drugs. Moreover, we have found this therapy to significantly improve blood glucose and insulin resistance in patients with type 2 diabetes. Based on this background of clinical efficacy, we validated changes in cerebral blood flow in patients with metabolic cardiovascular disease and examined the efficacy of Stress-free Therapy® on cerebral blood flow as compared to that in healthy control subjects and placebo-treated patients. Results: The change in cerebral blood flow volume during 15-minute PP-LILI was 5.1 ± 1.8 mL/min in patients with metabolic cardiovascular disease, showing a significant increase (P<0.05) of 3.1 mL/min as compared with the mean blood flow value after resting for 15 minutes. Conclusions: Our results suggested Stress-free Therapy® to significantly increase cerebral blood flow, possibly leading to the prevention of metabolic cardiovascular disease. PMID:24771966

  2. Nanofilm processors controlled by electrolyte flows of femtoliter volume.

    Science.gov (United States)

    Nolte, Marius; Knoll, Meinhard

    2013-06-25

    Nanofilm processors are a new kind of smart system based on the lateral self-oxidation of nanoscale aluminum films. The time dependency of these devices is controlled by electrolyte flows of femtoliter volume which can be modulated by different mechanisms. In this paper, we provide a deeper investigation of the electrolyte transport in the nanofilm processor and the different possibilities to control the aluminum oxidation velocity. A method for the in situ investigation of the acidic characteristic of the channel electrolyte is demonstrated. The obtained results form a set of instruments for constructing more complex electrolyte circuits and should allow the creation of nanofilm processors of arbitrary time dependence. Because the nanofilm processor combines different functional blocks and can operate in a self-sustained manner, without requiring batteries, this smart system may serve as a basis for many potential applications.

  3. Clinical Significance of Late Phase of Lung Perfusion Blood Volume (Lung Perfusion Blood Volume) Quantified by Dual-Energy Computed Tomography in Patients With Pulmonary Thromboembolism.

    Science.gov (United States)

    Koike, Hirofumi; Sueyoshi, Eijun; Sakamoto, Ichiro; Uetani, Masataka

    2017-01-01

    Using dual-energy computed tomography (DECT), we quantified the lung perfusion blood volume (PBV) in the late phase, which may reflect both the pulmonary artery and systemic collateral flow. We then investigated the clinical significance of late-phase lung PBV values. We retrospectively studied 206 patients (266 scans) who underwent early-phase and late-phase DECT. The patients were divided into 2 groups depending on whether or not they had pulmonary thromboembolism (PTE) (n=94 and 112). Patients with PTE were further divided into 2 subgroups, depending on whether they had acute PTE or chronic PTE (n=66 and 28). Pulmonary artery enhancement (PAenh) was measured on DECT. We then calculated the [lung PBV/PAenh] ratio in all patients during both the early and late phases for adjustment of timing. The [late-phase lung PBV/PAenh] ratio was 0.092±0.029 in the group with PTE and 0.108±0.030 in the group without PTE, showing a significant difference between the 2 groups (Plung PBV values/PAenh]/[late-phase lung PBV values/PAenh] ratio was 0.68±0.19 and 0.84±0.20, respectively, also showing a significant difference between the 2 groups (Plung PBV/PAenh]/[late-phase lung PBV/PAenh] ratio was 0.71±0.19 in patients with acute PTE and 0.56±0.16 in patients with chronic PTE, and there was a significant difference between these 2 subgroups (P=0.0004). It may be useful to determine late-phase lung PBV values in patients with PTE, because this parameter may reflect the systemic collateral flow, which is increased in chronic PTE.

  4. Left ventricular volume unloading with axial and centrifugal rotary blood pumps.

    Science.gov (United States)

    Giridharan, Guruprasad A; Koenig, Steven C; Soucy, Kevin G; Choi, Young; Pirbodaghi, Tohid; Bartoli, Carlo R; Monreal, Gretel; Sobieski, Michael A; Schumer, Erin; Cheng, Allen; Slaughter, Mark S

    2015-01-01

    Axial (AX) and centrifugal (CFG) rotary blood pumps have gained clinical acceptance for the treatment of advanced heart failure. Differences between AX and CFG designs and mechanism of blood flow delivery may offer clinical advantages. In this study, pump characteristics, and acute physiologic responses during support with AX (HeartMate II) and CFG (HVAD) left ventricular assist devices (LVAD) were investigated in mock loop and chronic ischemic heart failure bovine models. In the mock loop model, pump performance was characterized over a range of pump speeds (HeartMate II: 7,000-11,000 rpm, HVAD: 2,000-3,600 rpm) and fluid viscosities (2.7 cP, 3.2 cP, 3.7 cP). In the ischemic heart failure bovine model, hemodynamics, echocardiography, and end-organ perfusion were investigated. CFG LVAD had a flatter HQ curve, required less power, and had a more linear flow estimation relation than AX LVAD. The flow estimation error for the AX LVAD (±0.9 L/min at 2.7 cP, ±0.7 L/min at 3.2 cP, ±0.8 L/min at 3.7 cP) was higher than the CFG LVAD (±0.5 L/min at 2.7 cP, ±0.2 L/min at 3.2 cP, ±0.5 L/min at 3.7 cP). No differences in acute hemodynamics, echocardiography, or end-organ perfusion between AX and CFG LVAD over a wide range of support were statistically discernible. These findings suggest no pronounced acute differences in LV volume unloading between AX and CFG LVAD.

  5. High flow rates during modified ultrafiltration decrease cerebral blood flow velocity and venous oxygen saturation in infants.

    Science.gov (United States)

    Rodriguez, Rosendo A; Ruel, Marc; Broecker, Lothar; Cornel, Garry

    2005-07-01

    The intracranial hemodynamic effects of modified ultrafiltration in children are unknown. We investigated the effects of different blood flow rates during modified ultrafiltration on the cerebral hemodynamics of children with weights above and below 10 kg. Thirty-one children (weights: 10 kg, n = 10) undergoing cardiopulmonary bypass were studied. Middle-cerebral artery blood flow velocities and cerebral mixed venous oxygen saturations were measured before, five minutes from the beginning, and at the end of ultrafiltration. Patients were classified according to their blood flow rates during ultrafiltration in three groups: high (> or = 20 mL/kg/min), moderate (10-19 mL/kg/min), and low flow rates (flow rates of ultrafiltration and the decline in mean cerebral blood flow velocity (r = - 0.48; p = 0.005) and cerebral oxygen saturation (r = - 0.49; p = 0.005) or hematocrit increase (r = 0.59; p = 0.001). Infants exposed to high flow rates had greater reduction of cerebral blood flow velocity and regional mixed venous saturation and higher hematocrit at the end of ultrafiltration compared with those subjected to moderate and low flow rates (p flow rates through the ultrafilter during modified ultrafiltration transiently decrease the cerebral circulation in young infants compared with lower blood flow rates. These effects may be related to an increased diastolic runoff from the aorta into the ultrafiltration circuit that leads to a "stealing" effect from the intracranial circulation, which may be important in infants with dysfunctional cerebral autoregulation.

  6. Evaluation of the thyroid blood flow with Doppler ultrasonography in healthy school-aged children

    Energy Technology Data Exchange (ETDEWEB)

    Yazici, Burhan [Department of Radiology, Duzce University School of Medicine, Konuralp, Duzce 81620 (Turkey)], E-mail: dryazici@yahoo.com; Simsek, Enver [Department of Pediatrics, Duzce University School of Medicine, Konuralp, Duzce (Turkey); Erdogmus, Besir [Department of Radiology, Duzce University School of Medicine, Konuralp, Duzce 81620 (Turkey); Bahcebasi, Talat [Department of Public Health, Duzce University School of Medicine, Konuralp, Duzce (Turkey); Aktas, Alev [Department of Pediatrics, Duzce University School of Medicine, Konuralp, Duzce (Turkey); Buyukkaya, Ramazan [Department of Radiology, Duzce University School of Medicine, Konuralp, Duzce 81620 (Turkey); Uzun, Hakan [Department of Pediatrics, Duzce University School of Medicine, Konuralp, Duzce (Turkey); Safak, Alp Alper [Department of Radiology, Duzce University School of Medicine, Konuralp, Duzce 81620 (Turkey)

    2007-08-15

    Objective: To determine the relationship between thyroid blood flow and anthropometric measurements, pubertal stage, and thyroid and gonadotropic hormones. Materials and methods: We examined 123 healthy school-aged children prospectively (69 boys (56.1%) and 54 girls (43.9%), 7-17 years old). Their sex, age, body weight, height, body mass index (BMI), and pubertal stage were determined. Serum thyrotropin, free thyroxine, luteinizing hormone, and follicle stimulating hormone were measured in both genders, along with testosterone in boys and estradiol in girls. The peak systolic velocity (PSV), resistance index (RI), and pulsatility index (PI) of the superior thyroid artery were determined. The correlations between the Doppler parameters and these factors were investigated. Results: There were no differences in age, weight, height, BMI, thyroid volume, PSV, RI, or PI between boys and girls (P > 0.05). The PSV and PI showed strong correlations with age, height, weight, puberty stage, thyroid volume, and BMI. The RI showed a strong inverse correlation with age, height, weight, puberty stage, and thyroid volume and a weak inverse correlation with the BMI. Conclusion: Determination of the thyroid arterial flow in normal healthy children is important during a Doppler ultrasound (US) examination. Doppler US parameters and their percentiles should be described in healthy children from different age groups, and these percentiles will aid in interpreting Doppler US in children.

  7. Measuring Cerebral Blood Flow in Moyamoya Angiopathy by Quantitative Magnetic Resonance Angiography Noninvasive Optimal Vessel Analysis.

    Science.gov (United States)

    Khan, Nadia; Lober, Robert M; Ostergren, Lauren; Petralia, Jacob; Bell-Stephens, Teresa; Navarro, Ramon; Feroze, Abdullah; Steinberg, Gary K

    2017-12-01

    Moyamoya disease causes progressive occlusion of the supraclinoidal internal carotid artery, and middle, anterior, and less frequently the posterior cerebral arteries, carrying the risk of stroke. Blood flow is often partially reconstituted by compensatory moyamoya collaterals and sometimes the posterior circulation. Cerebral revascularization can further augment blood flow. These changes to blood flow within the cerebral vessels, however, are not well characterized. To evaluate blood flow changes resulting from the disease process and revascularization surgery using quantitative magnetic resonance angiography with noninvasive optimal vessel analysis (NOVA). We retrospectively analyzed 190 preoperative and postoperative imaging scans in 66 moyamoya patients after revascularization surgery. Images were analyzed for blood flow using NOVA and compared with preoperative angiographic staging and postoperative blood flow. Blood flow rates within superficial temporal artery grafts were compared based on angiographic evidence of patency. Diseased vessels had lower blood flow, correlating with angiographic staging. Flow in posterior cererbal and basilar arteries increased with disease severity, particularly when both the anterior and middle cerebral arteries were occluded. Basilar artery flow and ipsilateral internal carotid artery flow decreased after surgery. Flow rates were different between angiographically robust and poor direct bypass grafts, as well as between robust and patent grafts. Preoperative changes in cerebral vessel flow as measured by NOVA correlated with angiographic disease progression. NOVA demonstrated that preoperative augmentation of the posterior circulation decreased after surgery. This report is the first to quantify the shift in collateral supply from the posterior circulation to the bypass graft.

  8. The effect of the prior flow velocity on the structural organization of aggregated erythrocytes in the quiescent blood.

    Science.gov (United States)

    Pribush, Alexander; Meyerstein, Dan; Meyerstein, Naomi

    2011-02-01

    Usually, investigations of erythrocyte aggregation at rest are focused on effects of the strength of erythrocyte-erythrocyte attractive interactions and the volume fraction of the cells, whereas the role of prior flow velocity has not been thoroughly investigated. The aim of this study is to fill this gap. The main conclusions extracted from time records of the complex admittance of blood are as follows: (1) Dispersion of blood in a prior flow into discrete aggregates increases the mesh size of network, which, as has been recently shown, is formed in the quiescent blood. (2) If the energy of the flow field is sufficient to prevent the formation of face-to-side intercellular links, so that the dispersed phase consists of linear rouleaux, changes in the mesh size correlate positively with the length of rouleaux. (3) At slower prior flow velocities, the cells are combined into branched aggregates. As the degree of branching increases, the effect becomes less important. (4) The effects of the length of linear rouleaux and the degree of branching of ramified aggregates on the mesh size are qualitatively similar for suspensions with different aggregating media. (5) Erythrocytes suspended in strongly aggregating media form at low flow conditions a network-like structure. In this case, unlike high and moderate prior flow regimes, the mesh size of RBC network at rest is less than that formed after the stoppage of completely dispersed blood. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Changes in circulating blood volume after infusion of hydroxyethyl starch 6% in critically ill patients

    DEFF Research Database (Denmark)

    Christensen, P; Andersson, J; Rasmussen, S E

    2001-01-01

    The cardiovascular response to a volume challenge with hydroxyethyl starch (HES) (200/0.5) 6% depends on the relation between the volume of HES 6% infused and the expansion of the blood volume in critically ill patients. However, only relatively limited data exist on the plasma expanding effect...... of infusion of HES 6% in critically ill patients. The purpose of the study was to evaluate the variation in the expansion of the circulating blood volume (CBV) in critically ill patients after infusion of 500 ml of colloid (HES (200/0.5) 6%) using the carbon monoxide method....

  10. The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.

    Science.gov (United States)

    Burton, R. R.; Smith, A. H.

    1972-01-01

    Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.

  11. Fluid mechanics experiments in oscillatory flow. Volume 2: Tabulated data

    Science.gov (United States)

    Seume, J.; Friedman, G.; Simon, T. W.

    1992-01-01

    Results of a fluid mechanics measurement program in oscillating flow within a circular duct are presented. The program began with a survey of transition behavior over a range of oscillation frequency and magnitude and continued with a detailed study at a single operating point. Such measurements were made in support of Stirling engine development. Values of three dimensionless parameters, Re sub max, Re sub w, and A sub R, embody the velocity amplitude, frequency of oscillation, and mean fluid displacement of the cycle, respectively. Measurements were first made over a range of these parameters that are representative of the heat exchanger tubes in the heater section of NASA's Stirling cycle Space Power Research Engine (SPRE). Measurements were taken of the axial and radial components of ensemble-averaged velocity and rms velocity fluctuation and the dominant Reynolds shear stress, at various radial positions for each of four axial stations. In each run, transition from laminar to turbulent flow, and its reverse, were identified and sufficient data was gathered to propose the transition mechanism. Volume 2 contains data reduction program listings and tabulated data (including its graphics).

  12. Brain motion and volume transmission: Keeping the interstice flowing.

    Science.gov (United States)

    Picard, Nelson A; Zanardi, Carlos A

    2015-07-01

    Human brain undergoes two different kinds of movements: subtle pulsatile ones associated with the cardiac cycle and others of a greater magnitude related to breathing activity. These motions constitute a pumping force for the circulation of cerebrospinal fluid (CSF). Moreover, brain motion (BM) plays a fundamental role as a driving force for the interstitial and CSF flow of tracers. We hypothesize that BM is more than a mere consequence of cardiac and respiratory activities; that it would be part of a fundamental physiological mechanism by propelling the interstitial flow of messengers, a mechanism also known as 'non-synaptic transmission' or 'volume transmission' (VT). Intracranial hypertension (ICH), a frequent complication of severe head trauma, is related to brain stiffness. Under this circumstance, not only brain perfusion could be at risk, but BM could be engaged as well. Decompressive craniectomy, presently indicated to reduce ICH refractory to medical treatment, could play a role in helping BM and VT. Once brain swelling is overcome, the closure of the cranial bone defect would ensure the recovery of the spatial and temporal patterns of BM. We discuss evidence supportive of the necessary role of a minimal and sequential BM for an adequate VT. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Theory to predict particle migration and margination in the pressure-driven channel flow of blood

    Science.gov (United States)

    Qi, Qin M.; Shaqfeh, Eric S. G.

    2017-09-01

    The inhomogeneous concentration distribution of erythrocytes and platelets in microchannel flows particularly in directions normal to the mean flow plays a significant role in hemostasis, drug delivery, and microfluidic applications. In this paper, we develop a coarse-grained theory to predict these distributions in pressure-driven channel flow at zero Reynolds number and compare them to experiments and simulations. We demonstrate that the balance between the deformability-induced lift force and the shear-induced diffusion created by hydrodynamic interactions in the suspension results in both a peak concentration of red blood cells at the channel center and a cell-free or Fahraeus-Lindqvist layer near the walls. On the other hand, the absence of a lift force and the strong red blood cell-platelet interactions result in an excess concentration of platelets in the cell-free layer. We demonstrate a strong role of hematocrit (i.e., erythrocyte volume fraction) in determining the cell-free layer thickness and the degree of platelet margination. We also demonstrate that the capillary number of the erythrocytes, based on the membrane shear modulus, plays a relatively insignificant role in the regimes that we have studied. Our theory serves as a good and simple alternative to large-scale computer simulations of the cross-stream transport processes in these mixtures.

  14. Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

    Directory of Open Access Journals (Sweden)

    M Y Abdollahzadeh Jamalabadi

    Full Text Available Current paper is focused on transient modeling of blood flow through a tapered stenosed arteries surrounded a by solenoid under the presence of heat transfer. The oxygenated and deoxygenated blood are considered here by the Newtonian and Non-Newtonian fluid (power law and Carreau-Yasuda models. The governing equations of bio magnetic fluid flow for an incompressible, laminar, homogeneous, non-Newtonian are solved by finite volume method with SIMPLE algorithm for structured grid. Both magnetization and electric current source terms are well thought-out in momentum and energy equations. The effects of fluid viscosity model, Hartmann number, and magnetic number on wall shear stress, shearing stress at the stenosis throat and maximum temperature of the system are investigated and are optimized. The current study results are in agreement with some of the existing findings in the literature and are useful in thermal and mechanical design of spatially varying magnets to control the drug delivery and biomagnetic fluid flows through tapered arteries.

  15. Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

    Science.gov (United States)

    Abdollahzadeh Jamalabadi, M Y; Akbari Bidokhti, Amin Ali; Khak Rah, Hamid; Vaezi, Siavash; Hooshmand, Payam

    2016-01-01

    Current paper is focused on transient modeling of blood flow through a tapered stenosed arteries surrounded a by solenoid under the presence of heat transfer. The oxygenated and deoxygenated blood are considered here by the Newtonian and Non-Newtonian fluid (power law and Carreau-Yasuda) models. The governing equations of bio magnetic fluid flow for an incompressible, laminar, homogeneous, non-Newtonian are solved by finite volume method with SIMPLE algorithm for structured grid. Both magnetization and electric current source terms are well thought-out in momentum and energy equations. The effects of fluid viscosity model, Hartmann number, and magnetic number on wall shear stress, shearing stress at the stenosis throat and maximum temperature of the system are investigated and are optimized. The current study results are in agreement with some of the existing findings in the literature and are useful in thermal and mechanical design of spatially varying magnets to control the drug delivery and biomagnetic fluid flows through tapered arteries.

  16. Non-invasive determination of instantaneous brachial blood flow using the oscillometric method.

    Science.gov (United States)

    Liu, Shing-Hong; Wang, Jia-Jung; Cheng, Da-Chuan

    2009-08-01

    The oscillometric method has been widely used to measure arterial systolic and diastolic blood pressures, but its potential for arterial blood flow measurements still remains to be explored. The aim of this study was to non-invasively determine arterial blood flow using an oscillometric blood flow measurement system. The system consists of a pneumatic elastic cuff, an air-pumping motor, a releaser valve, a pressure transducer, and an airflow meter. To build a non-linear cuff model, we measured airflow pumped into the pneumatic cuff and cuff pressure using an airflow meter and pressure transducer during the inflation period, respectively. During the deflation period, only the pressure transducer was used to record cuff pressure. Based on the cuff model, the oscillometric blood flow waveform was obtained by integrating the oscillometric pressure waveform. We compared arterial blood flow derived from the maximum amplitude of the oscillometric blood flow waveform with Doppler-measured blood flow calculated with the diameters and blood velocities of the brachial arteries in 32 subjects who underwent diagnostic evaluations for peripheral arterial embolism. A linear correlation coefficient of r = 0.716 was found between the oscillometry- and Doppler-based blood flow measurements in the 32 subjects. These results suggest that blood flow passing through the brachial artery can be quantified non-invasively using the oscillometric approach after appropriate calibration.

  17. Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta.

    Science.gov (United States)

    Okamoto, Eiji; Yano, Tetsuya; Miura, Hidekazu; Shiraishi, Yasuyuki; Yambe, Tomoyuki; Mitamura, Yoshinori

    2017-12-01

    We have developed various axial flow blood pumps to realize the concept of the Valvo pump, and we have studied hemodynamic changes under cardiac assistance using an axial flow blood pump in series with the natural heart. In this study, we measured hemodynamic changes of not only systemic circulation but also cerebral circulation and coronary circulation under cardiac support using our latest axial flow blood pump placed in the descending aorta in an acute animal experiment. The axial flow blood pump was installed at the thoracic descending aorta through a left thoracotomy of a goat (43.8 kg, female). When the pump was on, the aortic pressure and aortic flow downstream of the pump increased with preservation of pulsatilities. The pressure drop upstream of the pump caused reduction of afterload pressure, and it may lead to reduction of left ventricular wall stress. However, cerebral blood flow and coronary blood flow were decreased when the pump was on. The axial flow blood pump enables more effective blood perfusion into systemic circulation, but it has the potential risk of blood perfusion disturbance into cerebral circulation and coronary circulation. The results indicate that the position before the coronary ostia might be suitable for implantation of the axial flow blood pump in series with the natural heart to avoid blood perfusion disturbances.

  18. Optical measurement of blood flow in exercising skeletal muscle: a pilot study

    Science.gov (United States)

    Wang, Detian; Baker, Wesley B.; Parthasarathy, Ashwin B.; Zhu, Liguo; Li, Zeren; Yodh, Arjun G.

    2017-07-01

    Blood flow monitoring during rhythm exercising is very important for sports medicine and muscle dieases. Diffuse correlation spectroscopy(DCS) is a relative new invasive way to monitor blood flow but suffering from muscle fiber motion. In this study we focus on how to remove exercise driven artifacts and obtain accurate estimates of the increase in blood flow from exercise. Using a novel fast software correlator, we measured blood flow in forearm flexor muscles of N=2 healthy adults during handgrip exercise, at a sampling rate of 20 Hz. Combining the blood flow and acceleration data, we resolved the motion artifact in the DCS signal induced by muscle fiber motion, and isolated the blood flow component of the signal from the motion artifact. The results show that muscle fiber motion strongly affects the DCS signal, and if not accounted for, will result in an overestimate of blood flow more than 1000%. Our measurements indicate rapid dilation of arterioles following exercise onset, which enabled blood flow to increase to a plateau of 200% in 10s. The blood flow also rapidly recovered to baseline following exercise in 10s. Finally, preliminary results on the dependence of blood flow from exercise intensity changes will be discussed.

  19. Effect of couple stresses on hydromagnetic flow of blood through a ...

    African Journals Online (AJOL)

    The function of the coronary network is to supply blood to the heart; however, in cases of Coronary Artery Disease, the geometry has great influence on the nature of the blood flow and the overall performance of the heart. In this paper, the unsteady non-Newtonian flow of blood under couple stresses and a uniform external ...

  20. Two and Three Dimensional Blood Flow Simulations in Different Types of Blood Vessels

    Directory of Open Access Journals (Sweden)

    Balazs ALBERT

    2015-12-01

    Full Text Available In this paper we present a synthesis of our results obtained on blood flow simulation in different types of blood vessels. We present first some remarks on the wall shear stress (WSS in the case of a human abdominal aortic aneurysm (AAA, and then we concentrate on the mechanical conditions which would lead to the “rupture” of the vascular vessel with aneurysm and implicitly to a possible stroke. We also make some investigations on the Fahraeus-Lindqvist effect in arterioles. Considering an axial-symmetric reservoir full of blood and which is linked to an arteriole (with the same particular geometry, we have pointed out the concentration of the red blood cells in this arteriole towards the core of the vessel. To improve our work we have considered a real three-dimensional geometry, which is a serious jump versus our previous results, where only the axial-symmetric geometries were considered. In this respect we have reconsidered the case of a carotid artery stenosis with and without a stent.

  1. Intensive blood pressure lowering increases cerebral blood flow in older subjects with hypertension.

    Science.gov (United States)

    Tryambake, Dinesh; He, Jiabao; Firbank, Michael J; O'Brien, John T; Blamire, Andrew M; Ford, Gary A

    2013-06-01

    Hypertension is associated with reduced cerebral blood flow (CBF). Intensive (blood pressure (BP) lowering in older people might give greater reduction in cardiovascular risk, but there are concerns that this might produce hypoperfusion which may precipitate falls and possibly stroke. We determined the effect of intensive compared with usual BP lowering on CBF in hypertensive older subjects. Individuals aged >70 years with a history of systolic hypertension on 1 or no BP lowering drugs were recruited from primary care (n=37; age, 75±4 years; systolic BP, >150 mm Hg) and randomized to receive intensive (target BP, hypertension increases CBF, compared with BP lowering to usual target. These findings suggest hypertension in older people shifts the autoregulatory CBF curve rightward and downward and is reversible with BP lowering.

  2. Intensive blood pressure control affects cerebral blood flow in type 2 diabetes mellitus patients

    DEFF Research Database (Denmark)

    Kim, Yu-Sok; Davis, Shyrin C A T; Truijen, Jasper

    2011-01-01

    Type 2 diabetes mellitus is associated with microvascular complications, hypertension, and impaired dynamic cerebral autoregulation. Intensive blood pressure (BP) control in hypertensive type 2 diabetic patients reduces their risk of stroke but may affect cerebral perfusion. Systemic hemodynamic...... variables and transcranial Doppler-determined cerebral blood flow velocity (CBFV), cerebral CO2 responsiveness, and cognitive function were determined after 3 and 6 months of intensive BP control in 17 type 2 diabetic patients with microvascular complications (T2DM+), in 18 diabetic patients without (T2DM...... patients with microvascular complications, indicating that maintenance of cerebral perfusion during BP treatment depends on the progression of microvascular disease. We suggest that BP treatment should be individualized, aiming at a balance between BP reduction and maintenance of CBFV....

  3. A simple model of cerebral blood flow dependence on arterial blood pressure

    CERN Document Server

    Gersten, Alexander

    2011-01-01

    It is shown that the dependence of the cerebral blood flow (CBF) on mean arterial blood pressure (MABP) can be described with a simple model having the following assumptions. Below certain MABP (denoted as MABP1) there are no autoregulatory or feedback mechanisms influencing CBF. Between MABP1 and MABP2 (MABP at which breakthrough accurs) there is a linear (on MABP) dependent feedback with a sloap depending very much on the individual considered. The classical autoregulation model with a plateau in between MABP1 and MABP2 is a particular case of this model. The model describes well the experiments performed on dogs (Harper 1966), for which the individual feedback sloap parameter varied to great extent, indicating the importance of mesurments on individuals against averaged mesurments (or measurments on diffent individuals) which superficially support the classical autoregulation. New effect of decreased CBF, while increasing MABP, was observed.

  4. Upper limit of cerebral blood flow autoregulation in experimental renovascular hypertension in the baboon

    DEFF Research Database (Denmark)

    Strandgaard, S; Jones, J V; MacKenzie, E T

    1975-01-01

    The effect of arterial hypertension on cerebral blood flow was studied by the intracarotid 133Xe clearance method in baboons. The arterial blood pressure was raised in gradual steps with angiotensin. Baboons with renal hypertension of 8-12 weeks duration were studied along with normotensive baboons....... In initially normotensive baboons, cerebral blood flow remained constant until the mean arterial blood pressure had risen to the range of 140 to 154 mm Hg; thereafter cerebral blood flow increased with each rise in mean arterial blood pressure. In the chronically hypertensive baboons, cerebral blood flow...... remained constant until the mean arterial blood pressure had been elevated to the range of 155 to 169 mm Hg. Thus, in chronic hypertension it appears that there are adaptive changes in the cerebral circulation which may help to protect the brain from further increases in arterial blood pressure....

  5. Black-blood native T1 mapping: Blood signal suppression for reduced partial voluming in the myocardium.

    Science.gov (United States)

    Weingärtner, Sebastian; Meßner, Nadja M; Zöllner, Frank G; Akçakaya, Mehmet; Schad, Lothar R

    2017-08-01

    To study the feasibility of black-blood contrast in native T1 mapping for reduction of partial voluming at the blood-myocardium interface. A saturation pulse prepared heart-rate-independent inversion recovery (SAPPHIRE) T1 mapping sequence was combined with motion-sensitized driven-equilibrium (MSDE) blood suppression for black-blood T1 mapping at 3 Tesla. Phantom scans were performed to assess the T1 time accuracy. In vivo black-blood and conventional SAPPHIRE T1 mapping was performed in eight healthy subjects and analyzed for T1 times, precision, and inter- and intraobserver variability. Furthermore, manually drawn regions of interest (ROIs) in all T1 maps were dilated and eroded to analyze the dependence of septal T1 times on the ROI thickness. Phantom results and in vivo myocardial T1 times show comparable accuracy with black-blood compared to conventional SAPPHIRE (in vivo: black-blood: 1562 ± 56 ms vs. conventional: 1583 ± 58 ms, P = 0.20); Using black-blood SAPPHIRE precision was significantly lower (standard deviation: 133.9 ± 24.6 ms vs. 63.1 ± 6.4 ms, P T1 time measurement was not possible. Significantly increased interobserver interclass correlation coefficient (ICC) (0.996 vs. 0.967, P = 0.011) and similar intraobserver ICC (0.979 vs. 0.939, P = 0.11) was obtained with the black-blood sequence. Conventional SAPPHIRE showed strong dependence on the ROI thickness (R(2) = 0.99). No such trend was observed using the black-blood approach (R(2) = 0.29). Black-blood SAPPHIRE successfully eliminates partial voluming at the blood pool in native myocardial T1 mapping while providing accurate T1 times, albeit at a reduced precision. Magn Reson Med 78:484-493, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. Quantitative assessment of limb blood flow using Tc-99m labeled red blood cells. Radionuclide venous occlusion plethysmography (RAVOP)

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Kazuo; Shougase, Takashi; Kawamura, Naoyuki; Tsukamoto, Eriko; Nakada, Kunihiro; Sakuma, Makoto; Furudate, Masayori

    1987-10-01

    A quantitative assessment of limb blood flow using a non-diffusible radioindicator, Tc-99m labeled red blood cells, was reported. This was an application of venous occlusion plethysmography using radionuclide which was originally proposed by M. Fukuoka et al. The peripheral blood flow (mean +- s.e.) of 30 legs in a normal control group was 1.87 +- 0.08 ml/100 ml/min. In heart diseases (46 legs), it was 1.49 +- 0.13 ml/100 ml/min. The limb blood flow between a control group and heart diseases was statistically significant (p < 0.01) in the t-test. The peripheral blood flow at rest between diseased legs and normal legs in occlusive arterial disorders was also statistically significant (p < 0.01) in a paired t-test. RAVOP was done after the completion of objective studies such as radionuclide angiography or ventriculography. Technique and calculation of a blood flow were very easy and simple. RAVOP study which was originally proposed by Fukuoka et al. was reappraised to be hopeful for quantitative measurement of limb blood flow as a non-invasive technique using Tc-99m labeled red blood cells.

  7. Correlation of volumetric flow rate and skin blood flow with cold intolerance in digital replantation.

    Science.gov (United States)

    Zhao, Gang; Mi, Jingyi; Rui, Yongjun; Pan, Xiaoyun; Yao, Qun; Qiu, Yang

    2017-12-01

    Cold intolerance is a common complication of digital replantation. The exact etiology is unclear, but it is considered to be multifactorial, including nonsurgical characteristics, vascular, and neurologic conditions. Blood flow may play a significant role in cold intolerance. This study was designed to evaluate the correlation of digital blood flow, including volumetric flow rate (VFR) and skin blood flow (SkBF), with cold intolerance in replanted fingers.A retrospective study was conducted among patients who underwent digital replantation between 2010 and 2013. Patients were selected into study cohort based on the inclusion criteria. Surgical data was collected on each patient, including age, sex, injury mechanism, amputation level, ischemia time, number of arteries repaired, and whether or not vascular crisis occurred. Patients were included as study cohort with both nerves repaired and without chronic disease. Cold intolerance was defined as a Cold Intolerance Symptom Severity (CISS) score over 30. The arterial flow velocity and caliber were measured by Color Doppler Ultrasound and the digital VFR was calculated. The SkBF was measured by Laser Speckle Imager. Both VFR and SkBF were calculated as a percentage of the contralateral fingers. Comparative study of surgical data and blood flow was performed between the patient with and without cold intolerance. Correlation between VFR and SkBF was also analyzed.A total of 93 patients met inclusion criteria for the study. Approximately, 42 patients were identified as having cold intolerance. Fingers that survived vascular crisis had a higher incidence of cold intolerance with a lower VFR and SkBF. The VFR was higher in 2-artery replantation, but the SkBF and incidence of cold intolerance did not differ significantly. No differences were found in age, sex, injury mechanism, amputation level, or ischemia time. Furthermore, no correlation was found between VFR and SkBF.Cold intolerance of digital replantation is associated

  8. Middle cerebral artery blood velocity and cerebral blood flow and O2 uptake during dynamic exercise

    DEFF Research Database (Denmark)

    Madsen, P L; Sperling, B K; Warming, T

    1993-01-01

    Results obtained by the 133Xe clearance method with external detectors and by transcranial Doppler sonography (TCD) suggest that dynamic exercise causes an increase of global average cerebral blood flow (CBF). These data are contradicted by earlier data obtained during less-well-defined conditions....... To investigate this controversy, we applied the Kety-Schmidt technique to measure the global average levels of CBF and cerebral metabolic rate of oxygen (CMRO2) during rest and dynamic exercise. Simultaneously with the determination of CBF and CMRO2, we used TCD to determine mean maximal flow velocity...... in the middle cerebral artery (MCA Vmean). For values of CBF and MCA Vmean a correction for an observed small drop in arterial PCO2 was carried out. Baseline values for global CBF and CMRO2 were 50.7 and 3.63 ml.100 g-1.min-1, respectively. The same values were found during dynamic exercise, whereas a 22% (P

  9. Effects of respiratory muscle work on respiratory and locomotor blood flow during exercise.

    Science.gov (United States)

    Dominelli, Paolo B; Archiza, Bruno; Ramsook, Andrew H; Mitchell, Reid A; Peters, Carli M; Molgat-Seon, Yannick; Henderson, William R; Koehle, Michael S; Boushel, Robert; Sheel, A William

    2017-11-01

    What is the central question of this study? Does manipulation of the work of breathing during high-intensity exercise alter respiratory and locomotor muscle blood flow? What is the main finding and its importance? We found that when the work of breathing was reduced during exercise, respiratory muscle blood flow decreased, while locomotor muscle blood flow increased. Conversely, when the work of breathing was increased, respiratory muscle blood flow increased, while locomotor muscle blood flow decreased. Our findings support the theory of a competitive relationship between locomotor and respiratory muscles during intense exercise. Manipulation of the work of breathing (WOB) during near-maximal exercise influences leg blood flow, but the effects on respiratory muscle blood flow are equivocal. We sought to assess leg and respiratory muscle blood flow simultaneously during intense exercise while manipulating WOB. Our hypotheses were as follows: (i) increasing the WOB would increase respiratory muscle blood flow and decrease leg blood flow; and (ii) decreasing the WOB would decrease respiratory muscle blood flow and increase leg blood flow. Eight healthy subjects (n = 5 men, n = 3 women) performed a maximal cycle test (day 1) and a series of constant-load exercise trials at 90% of peak work rate (day 2). On day 2, WOB was assessed with oesophageal balloon catheters and was increased (via resistors), decreased (via proportional assist ventilation) or unchanged (control) during the trials. Blood flow was assessed using near-infrared spectroscopy optodes placed over quadriceps and the sternocleidomastoid muscles, coupled with a venous Indocyanine Green dye injection. Changes in WOB were significantly and positively related to changes in respiratory muscle blood flow (r = 0.73), whereby increasing the WOB increased blood flow. Conversely, changes in WOB were significantly and inversely related to changes in locomotor blood flow (r = 0.57), whereby decreasing the

  10. Iodoamphetamine as a new tracer for local cerebral blood flow in the rat

    DEFF Research Database (Denmark)

    Rapin, J R; Le Poncin-Lafitte, M; Duterte, D

    1984-01-01

    blood flow and a more real estimation of hippocampal flow. It is concluded from the brain uptake of the derivatives of both amphetamines during the first minutes following their injection that these tracers can be used as a chemical microembolus for the measurement of local cerebral blood flow....

  11. What can we learn from Einstein and Arrhenius about the optimal flow of our blood?

    Science.gov (United States)

    Schuster, Stefan; Stark, Heiko

    2014-01-01

    The oxygen flow in humans and other higher animals depends on the erythrocyte-to-blood volume ratio, the hematocrit. Since it is physiologically favourable when the flow of oxygen transport is maximum it can be assumed that this situation has been achieved during evolution. If the hematocrit was too low, too few erythrocytes could transport oxygen. If it was too high, the blood would be very viscous, so that oxygen supply would again be reduced. The theoretical optimal hematocrit can be calculated by considering the dependence of blood viscosity on the hematocrit. Different approaches to expressing this dependence have been proposed in the literature. Here, we discuss early approaches in hydrodynamics proposed by Einstein and Arrhenius and show that especially the Arrhenius equation is very appropriate for this purpose. We show that despite considerable simplifications such as neglecting the deformation, orientation and aggregation of erythrocytes, realistic hematocrit values of about 40% can be derived based on optimality considerations. Also the prediction that the ratio between the viscosities of the blood and blood plasma at high shear rates nearly equals Euler's constant (2.718) is in good agreement with observed values. Finally, we discuss possible extensions of the theory. For example, we derive the theoretical optimal hematocrit for persevering divers among marine mammals to be 65%, in excellent agreement with the values observed in several species. These considerations are very important for human and animal physiology since oxygen transport is an important factor for medicine and physical performance. © 2013 Elsevier B.V. All rights reserved.

  12. Bifurcation study of blood flow control in the kidney

    Science.gov (United States)

    Ford Versypt, Ashlee N.; Makrides, Elizabeth; Arciero, Julia C.; Ellwein, Laura; Layton, Anita T.

    2016-01-01

    Renal blood flow is maintained within a narrow window by a set of intrinsic autoregulatory mechanisms. Here, a mathematical model of renal hemodynamics control in the rat kidney is used to understand the interactions between two major renal autoregulatory mechanisms: the myogenic response and tubuloglomerular feedback. A bifurcation analysis of the model equations is performed to assess the effects of the delay and sensitivity of the feedback system and the time constants governing the response of vessel diameter and smooth muscle tone. The results of the bifurcation analysis are verified using numerical simulations of the full nonlinear model. Both the analytical and numerical results predict the generation of limit cycle oscillations under certain physiologically relevant conditions, as observed in vivo. PMID:25747903

  13. History of International Society for Cerebral Blood Flow and Metabolism

    DEFF Research Database (Denmark)

    Paulson, Olaf B; Kanno, Iwao; Reivich, Martin

    2012-01-01

    Interest in the brain's circulation dates back more than a century and has been steadily growing. Quantitative methods for measurements of cerebral blood flow (CBF) and energy metabolism became available in the middle of the 20th century and gave a new boost to the research. Scientific meetings...... since then been a major success. The development of new brain imaging methods has had a major impact. Regulation of CBF and ischemia has been the main topics at the meetings. A new field of brain mapping research emerged and has now its own society and meetings. Brain emission tomography research has...... grown within the society and is now an integrated part. The ISCBFM is a sound society, and support of young scientists is among its goals. Several awards have been established. Other activities including summer schools, courses, satellite meetings, and Gordon conferences have contributed to the success...

  14. Cerebral blood flow response to propranolol in streptozotocin diabetic rats

    DEFF Research Database (Denmark)

    Lass, Preben; Knudsen, G M

    1990-01-01

    The influence of propranolol on cerebral blood flow (CBF) was tested in streptozotocin diabetic rats and in control animals. Resting CBF values were 40% lower in the diabetic rats compared with controls. Intravenous injection of propranolol (2 mg kg-1) decreased CBF significantly in the control...... group; the CBF decreased for 15 min after propranolol injection and returned to baseline values after 90 min. In the diabetic rats, the CBF declined steadily but this decrease did not reach significance, even after 90 min. Impaired beta-adrenergic mechanisms may be an important factor in the CBF...... alterations which occur in diabetes mellitus. Further, it is suggested that an impaired CBF response may play a role in CNS lesions in diabetic patients treated with beta antagonists....

  15. Repeated blood flow restriction induces muscle fiber hypertrophy.

    Science.gov (United States)

    Sudo, Mizuki; Ando, Soichi; Kano, Yutaka

    2017-02-01

    We recently developed an animal model to investigate the effects of eccentric contraction (ECC) and blood flow restriction (BFR) on muscle tissue at the cellular level. This study clarified the effects of repeated BFR, ECC, and BFR combined with ECC (BFR+ECC) on muscle fiber hypertrophy. Male Wistar rats were assigned to 3 groups: BFR, ECC, and BFR+ECC. The contralateral leg in the BFR group served as a control (CONT). Muscle fiber cross-sectional area (CSA) of the tibialis anterior was determined after the respective treatments for 6 weeks. CSA was greater in the BFR+ECC group than in the CONT (P hypertrophy at the cellular level. Muscle Nerve 55: 274-276, 2017. © 2016 Wiley Periodicals, Inc.

  16. Cerebral blood flow and oxygen metabolism in the Rett syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Hideto; Fueki, Noboru; Suzuki, Hisaharu; Sakuragawa, Norio; Iio, Masaaki (National Central Hospital for Mental, Nervous and Muscular Disorders, Tokyo (Japan))

    1992-05-01

    Positron emission tomography (PET) was performed on six patients with the Rett syndrome and the results were compared with the concurrent clinical status of the patients. The cerebral metabolic rate of oxygen (CMRO{sub 2}) was low in five patients, and oxygen extraction fraction (OEF) was low in four patients; both had a tendency to decline with advancing age. Although the cause is unknown, it is suggested that impaired oxidative metabolism exists in the Rett syndrome. An analysis of the distribution among brain regions showed that the ratios of values for the frontal cortex to those for the temporal cortex for both the cerebral blood flow (CBF) and CMRO{sub 2} were lower than those for the controls, which may indicate the loss of of hyperfrontality in the Rett syndrome. Distribution of brain metabolism may be immature in the Rett syndrome. (author).

  17. Brain energy metabolism and blood flow differences in healthy aging

    DEFF Research Database (Denmark)

    Aanerud, Joel; Borghammer, Per; Chakravarty, M Mallar

    2012-01-01

    Cerebral metabolic rate of oxygen consumption (CMRO(2)), cerebral blood flow (CBF), and oxygen extraction fraction (OEF) are important indices of healthy aging of the brain. Although a frequent topic of study, changes of CBF and CMRO(2) during normal aging are still controversial, as some authors...... find decreases of both CBF and CMRO(2) but increased OEF, while others find no change, and yet other find divergent changes. In this reanalysis of previously published results from positron emission tomography of healthy volunteers, we determined CMRO(2) and CBF in 66 healthy volunteers aged 21 to 81......, and in the temporal cortex. Because of the inverse relation between OEF and capillary oxygen tension, increased OEF can compromise oxygen delivery to neurons, with possible perturbation of energy turnover. The results establish a possible mechanism of progression from healthy to unhealthy brain aging, as the regions...

  18. Cerebral Blood Flow Responses to Aquatic Treadmill Exercise.

    Science.gov (United States)

    Parfitt, Rhodri; Hensman, Marianne Y; Lucas, Samuel J E

    2017-07-01

    Aquatic treadmills are used as a rehabilitation method for conditions such as spinal cord injury, osteoarthritis, and stroke, and can facilitate an earlier return to exercise training for athletes. However, their effect on cerebral blood flow (CBF) responses has not been examined. We tested the hypothesis that aquatic treadmill exercise would augment CBF and lower HR compared with land-based treadmill exercise. Eleven participants completed incremental exercise (crossover design) starting from walking pace (4 km·h, immersed to iliac crest [aquatic], 6 km·h [land]) and increasing 1 km·h every 2 min up to 10 km·h for aquatic (maximum belt speed) or 12 km·h for land. After this, participants completed two 2-min bouts of exercise immersed to midthigh and midchest at constant submaximal speed (aquatic), or were ramped to exhaustion (land; increased gradient 2° every min). Middle cerebral artery blood flow velocity (MCAv) and HR were measured throughout, and the initial 10 min of each protocol and responses at each immersion level were compared. Compared with land-based treadmill, MCAvmean increased more from baseline for aquatic exercise (21% vs 12%, P aquatic walking compared with land-based moderate intensity running (~10 cm·s, P = 0.56). Greater water immersion lowered HR (139 vs 178 bpm for midchest vs midthigh), whereas MCAvmean remained constant (P = 0.37). Findings illustrate the potential for aquatic treadmill exercise to enhance exercise-induced elevations in CBF and thus optimize shear stress-mediated adaptation of the cerebrovasculature.

  19. Ventilatory response in metabolic acidosis and cerebral blood volume in humans.

    NARCIS (Netherlands)

    Ven, M.T.P. van de; Colier, W.N.J.M.; Sluijs, M.C. van der; Oeseburg, B.; Folgering, H.T.M.

    2001-01-01

    The relationship between alterations in cerebral blood volume (CBV) and central chemosensitivity regulation was studied under neutral metabolic conditions and during metabolic acidosis. Fifteen healthy subjects (5610 years) were investigated. To induce metabolic acidosis, ammonium chloride (NH(4)Cl)

  20. Synthetic reconstruction of dynamic blood flow in cortical arteries using optical coherence tomography for the evaluation of vessel compliance

    Science.gov (United States)

    Baraghis, Edward; Bolduc, Virginie; Gillis, Marc-Antoine; Srinivasan, Vivek J.; Thorin, Éric; Boudoux, Caroline; Lesage, Frédéric

    2011-03-01

    Optical Coherence Tomography (OCT) has recently been used to produce 3D angiography of microvasculature in the rodent brain in-vivo and blood flow maps of large vessels. Key enabling developments were novel algorithms for detecting Doppler shifts produced by moving scatterers and new scanning protocols tailored to increase sensitivity to small flow speeds. These progresses were pushed by the need for a non invasive imaging modality to monitor quantitative blood flow at a higher resolution and a greater depth than could be achieved by other means. The rationale for this work originates from new hypotheses regarding the role of blood regulation in neurodegenerative diseases and from current investigations of animal models of vascular degeneration. In this work we demonstrate the synthetic reconstruction of dynamic blood flow in mice over the course of a single cardiac cycle in an 800μm wide by ~ 3mm deep B-Frame slice with a lateral resolution of 10μm and a depth resolution of 7μm. Images were taken using a cranial window over the exposed parietal bone of mice skull. Electrocardiography (ECG) recordings were co registered with the OCT A lines at high temporal resolution. QRS peak detection was then used to locate the time value of each A-line in the cardiac cycle and to reconstruct a synthetic temporal frame over one cardiac cycle. Doppler speed in this cardiac cycle was used to measure temporal variations of flow inside arteries and of their area. Three dimensional volume scans yielded measurements of quantitative blood flow on the same arteries. Using these informations a measure of compliance could be established. Comparing measures between atherosclerotic (ATX) and wild type (WT) mice revealed higher blood flow in WT mice, suggested lower systemic compliance in the ATX group but higher compliance of cerebral vasculature on these mice. These results are consistent with expectations showing that OCT is a potential tool for in-vivo arterial compliance evaluation.

  1. SAFETY CONSIDERATIONS WITH BLOOD FLOW RESTRICTED RESISTANCE TRAINING

    Directory of Open Access Journals (Sweden)

    Alan Kacin

    2015-11-01

    Full Text Available Blood flow restricted resistance (BFRR training with pneumatic tourniquet has been suggested as an alternative for conventional weight training due to the proven benefits for muscle strength and hypertrophy using relatively low resistance, hence reducing the mechanical stress across a joint. As such, it has become an important part of rehabilitation programs used in either injured or operated athletes. Despite a general consensus on effectiveness of BFRR training for muscle conditioning, there are several uncertainties regarding the interplay of various extrinsic and intrinsic factors on its safety and efficiency, which are being reviewed from a clinical perspective. Among extrinsic factors tourniquet cuff pressure, size and shape have been identified as key for safety and efficiency. Among intrinsic factors, limb anthropometrics, patient history and presence of cardiac, vascular, metabolic or peripheral neurologic conditions have been recognized as most important. Though there are a few potential safety concerns connected to BFRR training, the following have been identified as the most probable and health-hazardous: (a mechanical injury to the skin, muscle, and peripheral nerves, (b venous thrombosis due to vascular damage and disturbed hemodynamics and (c augmented arterial blood pressure responses due to combined high body exertion and increased peripheral vascular resistance. Based on reviewed literature and authors’ personal experience with the use of BFRR training in injured athletes, some guidelines for its safe application are outlined. Also, a comprehensive risk assessment tool for screening of subjects prior to their inclusion in a BFRR training program is being introduced.

  2. Changes in maxillary molar pulp blood flow during orthodontic intrusion.

    Science.gov (United States)

    Sabuncuoglu, Fidan Alakus; Ersahan, Seyda

    2014-11-01

    The aim of this prospective study was to evaluate the effects of maxillary first molar intrusion on pulpal blood flow (PBF) in humans as recorded by laser Doppler flowmetry (LDF). Maxillary first molars of 16 participants were divided into two groups. In the study group, 20 teeth in 10 participants were subjected to an intrusive force of 100 g delivered from mini-implants for 6 months. A control group of 6 subjects (12 teeth) received no orthodontic treatment. LDF measurements were recorded at baseline and at 3 days, 3 weeks, 3 months and 6 months during intrusion. Data was analysed using the Wilcoxon Signed Rank and Mann-Whitney U tests, with a level of p intrusion with mini-implants and an applied force of 100 g, blood vessel function was maintained throughout intrusion, as indicated by LDF measurements of PBF, which tended to return to baseline values by the end of the observation period. These results highlight the changes that can occur in molar vascularity, especially during six months of intrusion.

  3. Variations in respiratory excretion of carbon dioxide can be used to calculate pulmonary blood flow.

    Science.gov (United States)

    Preiss, David A; Azami, Takafumi; Urman, Richard D

    2015-02-01

    A non-invasive means of measuring pulmonary blood flow (PBF) would have numerous benefits in medicine. Traditionally, respiratory-based methods require breathing maneuvers, partial rebreathing, or foreign gas mixing because exhaled CO2 volume on a per-breath basis does not accurately represent alveolar exchange of CO2. We hypothesized that if the dilutional effect of the functional residual capacity was accounted for, the relationship between the calculated volume of CO2 removed per breath and the alveolar partial pressure of CO2 would be reversely linear. A computer model was developed that uses variable tidal breathing to calculate CO2 removal per breath at the level of the alveoli. We iterated estimates for functional residual capacity to create the best linear fit of alveolar CO2 pressure and CO2 elimination for 10 minutes of breathing and incorporated the volume of CO2 elimination into the Fick equation to calculate PBF. The relationship between alveolar pressure of CO2 and CO2 elimination produced an R(2) = 0.83. The optimal functional residual capacity differed from the "actual" capacity by 0.25 L (8.3%). The repeatability coefficient leveled at 0.09 at 10 breaths and the difference between the PBF calculated by the model and the preset blood flow was 0.62 ± 0.53 L/minute. With variations in tidal breathing, a linear relationship exists between alveolar CO2 pressure and CO2 elimination. Existing technology may be used to calculate CO2 elimination during quiet breathing and might therefore be used to accurately calculate PBF in humans with healthy lungs.

  4. Airway blood flow response to dry air hyperventilation in sheep

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, G.H.; Baile, E.M.; Pare, P.D.

    1986-03-01

    Airway blood flow (Qaw) may be important in conditioning inspired air. To determine the effect of eucapneic dry air hyperventilation (hv) on Qaw in sheep the authors studied 7 anesthetized open-chest sheep after 25 min. of warm dry air hv. During each period of hv the authors have recorded vascular pressures, cardiac output (CO), and tracheal mucosal and inspired air temperature. Using a modification of the reference flow technique radiolabelled microspheres were injected into the left atrium to make separate measurements after humid air and dry air hv. In 4 animals a snare around the left main pulmonary artery was used following microsphere injection to prevent recirculation (entry into L lung of microspheres from the pulmonary artery). Qaw to the trachea and L lung as measured and Qaw for the R lung was estimated. After the final injection the sheep were killed and bronchi (Br) and lungs removed. Qaw (trachea plus L lung plus R lung) in 4 sheep increased from a mean of 30.8 to 67.0 ml/min. Airway mucosal temp. decreased from 39/sup 0/ to 33/sup 0/C. The authors conclude that dry air hv cools airway mucosa and increases Qaw in sheep.

  5. Whole brain C-arm computed tomography parenchymal blood volume measurements.

    Science.gov (United States)

    Kamran, Mudassar; Byrne, James V

    2016-04-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) imaging in the neuro-interventional suite is a new technique for which detailed whole brain measurements have not been previously reported. This study aims to create a catalogue of PBV measurements for various anatomical regions encompassing the whole brain, using a three-dimensional volume-of-interest (3D-VOI) analysis. We acquired and analysed 30 C-arm FDCT datasets from 26 patients with aneurysmal subarachnoid haemorrhage (SAH), as part of a prospective study comparing C-arm computed tomography (CT) PBV with magnetic resonance perfusion-weighted imaging (MR-PWI). We calculated the PBV values for various brain regions with an automated analysis, using 58 pre-defined atlas-based 3D-VOIs encompassing the whole brain. VOIs partially or completely overlapping regions of magnetic resonance diffusion weighted imaging (MR-DWI) abnormality or magnetic resonance cerebral blood flow (MR-CBF) asymmetry were excluded from the analysis. Of the 30 C-arm CT PBV datasets, 14 (54%; 12 patients) had areas of restricted diffusion, the majority of which were focal. The PBV values for the cerebral cortex and cerebral white matter were 4.01 ± 0.47 (mean ± SD) and 3.01 ± 0.39 ml per 100 ml. Lobar PBV values were: frontal lobe 4.2 ± 0.8, temporal lobe 4.2 ± 0.9, parietal lobe 3.9 ± 0.7 and occipital lobe 4.3 ± 0.8 ml/100 ml. The basal ganglia and brainstem PBV values were 3.4 ± 0.7 and 4.6 ± 0.6 ml/100 ml, respectively. Compared with the typical reference cerebral blood volume (CBV) values reported in the literature for Positron Emission Tomography (PET), the PBV values were relatively high for the white matter and relatively low for the cortical grey matter. The reported catalogue of PBV values for various brain regions would be useful to inform future studies and could be used in clinical practice, when interpreting PBV maps. © The Author(s) 2016.

  6. Impact of mydriatic eye drops on neonatal cerebral blood flow

    Directory of Open Access Journals (Sweden)

    Atef Alshafei

    2017-11-01

    Full Text Available Retinopathy of prematurity (ROP screening is a common routine procedure carried out on preterm infants in neonatal intensive care units (NICUs. Mydriatic eye drops containing phenylephrine hydrochloride 2.5% (a sympathomimetic agent and tropicamide 0.5% (a cycloplegic medication are readily absorbed from the conjunctiva and produce systemic responses in various organs. To our knowledge, no studies have investigated the direct effects of these medications on cerebral blood flow velocities (CBFVs in preterm infants. To evaluate the systemic effects of locally instilled mydriatic eye drops (phenylephrine hydrochloride 2.5% and tropicamide 0.5% used for ROP screening, on cerebral blood flow velocity in preterm infants, a prospective observational study was conducted among preterm infants with gestational age (GA < 31 weeks admitted to the NICU at Dubai Hospital between February 20, 2017 and June 20, 2017. The infants (at a post-menstrual age of 31-34 weeks underwent duplex ultrasound evaluation of CBFV before and after mydriatic eye drops administration.Pulsed-wave Doppler ultrasound studies were performed 1 h before and 1 h after eye mydriasis. We measured peak systolic velocity (PSV and end diastolic velocity (EDV for both the anterior cerebral artery (ACA and middle cerebral artery (MCA and calculated the resistive index (RI, defined as PSV – EDV/PSV. Mean arterial blood pressure (MAP, heart rate, oxygen saturation and pain score were assessed before and 1 h after ROP examination.A paired t-test and McNemar’s test were used to assess the statistical significance of the difference between pairs of means and the qualitative variables measured twice for the same study group.Among the 42 eligible preterm infants, the mean (SD GA was 27 (2.68 weeks (range, 24-31 weeks. The mean (SD RI of ACA before and 1 h after eye drops administration was 0.84 (0.06 and 0.83 (0.07 respectively (p = 0.453. The mean (SD RIs of MCA before and then 1 h after

  7. Mimicking the Interfacial Dynamics of Flowing White Blood Cells

    Science.gov (United States)

    Santore, Maria

    2015-03-01

    The rolling of particles on surfaces, facilitated by hydrodynamic forces combined with localized surface interactions of the appropriate strengths, spatial arrangements, and ranges, is a technologically useful means of transporting and manipulating particles. One's intuition for the rolling of a marble or a car tire cannot be extrapolated down to microparticle length scales because the microparticle interactions are dominated by electrostatic, van der Waals, and hydrogen bonding interactions rather than a friction that depends on an imposed normal force. Indeed, our microparticle rolling systems are inspired by the rolling of white blood cells on the inner walls of venules as part of the innate immune response: Selectin molecules engage with their counterparts on the opposing surfaces to slow cell motion relative to that for freely flowing cells. In the resulting rolling signature, ligand-receptor binding and crack closing on the front of the cell are balanced with molecular dis-bonding and crack opening at the rear. The contact region is relatively static, allowing other interactions (for instance signaling) to occur for a finite duration. Thus, achieving particle rolling in synthetic systems is important because it facilitates particle-surface interactions in a continuous nonfouling fashion where the contact surface is continually renewed. In developing a synthetic model for this system, we employ polymers to modify flowing particles and /or planar collectors, producing heterogeneous interfaces which can support rolling or produce other motion signatures such as skipping, arrest, or free flow. We identify, in the synthetic system, combinations of variables that produce rolling and demonstrate how the distinction between rolling and arrest is not a simple matter of the adhesion strength between the particles and the collector. Rolling is a cooperative process and the coordination of binding in one location with dis-bonding in another requires appropriate length

  8. Skeletal blood flow in Paget's disease of bone and its response to calcitonin therapy.

    Science.gov (United States)

    Wootton, R; Reeve, J; Spellacy, E; Tellez-Yudilevich, M

    1978-01-01

    1. Blood flow to the skeleton was measured by the 18F clearance method of Wooton, Reeve & Veall (1976) in 24 patients with untreated Paget's disease. In every patient but one, resting skeletal blood flow was increased. There was a significant positive correlation between skeletal blood flow and serum alkaline phosphatase and between skeletal blood flow and urinary total hydroxyproline excretion. 2. Fourteen patients were re-studied after they had received short-term (7 days or less) or long-term (7 weeks or more) calcitonin. Skeletal blood flow, alkaline phosphatase and urinary hydroxy-proline excretion fell towards normal in every case. There was some evidence from the short-term studies that calcitonin produced a more rapid fall in skeletal blood flow than in alkaline phosphatase. 3. Glomerular filtration rate appeared to increase transiently in response to calcitonin.

  9. Timing and topography of cerebral blood flow, aura, and headache during migraine attacks

    DEFF Research Database (Denmark)

    Olesen, J; Friberg, L; Olsen, T S

    1990-01-01

    Ten years of study has resulted in considerable but fragmented knowledge about regional cerebral blood flow in migraine with aura (classic migraine). In the present study, the number of repeatedly studied patients (n = 63) was large enough to determine statistically significant sequences of events...... and statistically significant spatial relations. The first observable event was a decrease of regional cerebral blood flow posteriorly in one cerebral hemisphere. Further development of this pathological process was accompanied by the aura symptoms. Thereafter headache occurred while regional cerebral blood flow...... remained decreased. During the headache phase, regional cerebral blood flow gradually changed from abnormally low to abnormally high without apparent change in headache. In some patients headache disappeared while regional cerebral blood flow remained increased. Although regional cerebral blood flow...

  10. Sympathetic reflex control of subcutaneous blood flow in tetraplegic man during postural changes

    DEFF Research Database (Denmark)

    Skagen, K; Jensen, K; Henriksen, O

    1982-01-01

    to the labelled area. Leg blood flow was unaltered by proximal blockade but could be blocked by local infiltration in the labelled area with lignocaine in low doses. 4. Head-up tilt of tetraplegic patients induced vasoconstriction in the subcutaneous tissue of the forearm, which could be prevented by proximal......1. The effect of head-up tilt upon subcutaneous blood flow in the distal arm and leg was studied in 12 patients with complete traumatic spinal cord transection at the cervical level. 2. Blood flow was measured by the local 133Xe washout technique. 3. Leg lowering induced a 47% decrease in blood...... flow in the distal leg. During head-up tilt (45 degrees) blood flow in the leg decreased by 48%. In the arm remaining at heart level blood flow decreased by 37% during tilt and this vasoconstriction could be prevented by nervous blockade with lignocaine injected subcutaneously 5 cm proximally...

  11. Analysis of chaotic and noise processes in a fluctuating blood flow using the Allan variance technique.

    Science.gov (United States)

    Basarab, M A; Basarab, D A; Konnova, N S; Matsievskiy, D D; Matveev, V A

    2016-01-01

    The aim of this work was to develop a novel technique for digital processing of Doppler ultrasound blood flow sensor data from noisy blood flow velocity waveforms. To evaluate the fluctuating blood flow parameters, various nonlinear dynamics methods and algorithms are often being used. Here, for identification of chaotic and noise components in a fluctuating coronary blood flow, for the first time the Allan variance technique was used. Analysis of different types of noises (White, Brownian, Flicker) was carried out and their strong correlation with fractality of time series (the Hurst exponent) was revealed. Based on a specialized software realizing the developed technique, numerical experiments with real clinical data were carried out. Recommendations for identification of noisy patterns of coronary blood flow in normal and pathological states were developed. The methodology gives us the possibility for the more detailed quantitative and qualitative analysis of a noisy fluctuating blood flow data.

  12. A comparison of Newtonian and non-Newtonian models for pulsatile blood flow simulations

    Science.gov (United States)

    Husain, Iqbal; Labropulu, Fotini; Langdon, Chris; Schwark, Justin

    2013-04-01

    Mathematical modeling of blood flows in the arteries is an important and challenging problem. This study compares several non-Newtonian blood models with the Newtonian model in simulating pulsatile blood flow through two three-dimensional models of an arterial stenosis and an aneurysm. Four non-Newtonian blood models, namely the Power Law, the Casson, the Carreau, and the Generalized Power Law, as well as the Newtonian model of blood viscosity, are used to investigate the flow effects induced by these different blood constitutive equations. The aim of this study is three-fold: firstly, to investigate the variation in wall shear stress in an artery with a stenosis or aneurysm at different flow rates and degrees of severity; secondly, to compare the various blood models and hence quantify the differences between the models and judge their significance; and lastly, to determine whether the use of the Newtonian blood model is appropriate over a wide range of shear rates.

  13. Statistical dynamics of flowing red blood cells by morphological image processing.

    Directory of Open Access Journals (Sweden)

    John M Higgins

    2009-02-01

    Full Text Available Blood is a dense suspension of soft non-Brownian cells of unique importance. Physiological blood flow involves complex interactions of blood cells with each other and with the environment due to the combined effects of varying cell concentration, cell morphology, cell rheology, and confinement. We analyze these interactions using computational morphological image analysis and machine learning algorithms to quantify the non-equilibrium fluctuations of cellular velocities in a minimal, quasi-two-dimensional microfluidic setting that enables high-resolution spatio-temporal measurements of blood cell flow. In particular, we measure the effective hydrodynamic diffusivity of blood cells and analyze its relationship to macroscopic properties such as bulk flow velocity and density. We also use the effective suspension temperature to distinguish the flow of normal red blood cells and pathological sickled red blood cells and suggest that this temperature may help to characterize the propensity for stasis in Virchow's Triad of blood clotting and thrombosis.

  14. Very low cerebral blood volume predicts parenchymal hematoma in acute ischemic stroke

    DEFF Research Database (Denmark)

    Hermitte, Laure; Cho, Tae-Hee; Ozenne, Brice

    2013-01-01

    BACKGROUND AND PURPOSE: Parenchymal hematoma (PH) may worsen the outcome of patients with stroke. The aim of our study was to confirm the relationship between the volume of very low cerebral blood volume (CBV) and PH using a European multicenter database (I-KNOW). A secondary objective was to exp...

  15. Mathematical Models and Numerical Simulations for the Blood Flow in Large Vessels

    OpenAIRE

    Titus PETRILA; Balazs ALBERT

    2012-01-01

    We are proposing a non-Newtonian, Cross type rheological model for the blood flow, under the conditions of an unsteady flow regime connected with the rhythmic pumping of the blood by the heart. We admit the incompressibility and homogeneity of the blood while its flow is laminar and the exterior body forces are neglected. We take also into account the viscoelastic behavior of the vessel walls. The mathematical equations and the appropriate boundary conditions are considered in cylindrical (ax...

  16. Skin and muscle components of forearm blood flow in directly heated resting man.

    Science.gov (United States)

    Detry, J.-M. R.; Brengelmann, G. L.; Rowell, L. B.; Wyss, C.

    1972-01-01

    Changes in forearm muscle blood flow (FMBF) during direct whole-body heating were measured in 17 normal subjects using three different methods. We conclude that FMBF is not increased by direct whole-body heating. Since renal and splanchnic blood flow fall 30% under these conditions, maximal total skin blood flow in 12 previously studied subjects can be estimated from the rise in cardiac output to be 7.6 L/min (3.0-11.1 L/min).

  17. Face cooling with mist water increases cerebral blood flow during exercise: Effect of changes in facial skin blood flow

    Directory of Open Access Journals (Sweden)

    Taiki eMiyazawa

    2012-08-01

    Full Text Available Facial cooling (FC increases cerebral blood flow (CBF at rest and during exercise; however, the mechanism of this response remains unclear. The purpose of the present study was to test our hypothesis that FC causes facial vasoconstriction that diverts skin blood flow (SkBFface towards the middle cerebral artery (MCA Vmean at rest and to a greater extent during exercise. Nine healthy young subjects (20 ± 2 yrs. underwent 3 minutes of FC by fanning and spraying the face with a mist of cold water (~4˚C at rest and during steady-state exercise (heart rate of 120 bpm. We focused on the difference between the averaged data acquired from 1 min immediately before FC and last 1 min of FC. SkBFface, MCA Vmean and MAP were higher during exercise than at rest. As hypothesized, FC decreased SkBFface at rest (-32 ± 4 % and to a greater extent during exercise (-64 ± 10%, P=0.012. Although MCA Vmean was increased by FC (Rest, +1.4 ± 0.5 cm/s; Exercise, +1.4 ± 0.6 cm/s, the amount of the FC-evoked changes in MCA Vmean at rest and during exercise differed among subjects. In addition, changes in MCA Vmean with FC did not correlate with concomitant changes in SkBFface (r=0.095, P=0.709. MAP was also increased by FC (Rest, +6.2 ± 1.4 mmHg; Exercise, +4.2 ± 1.2 mmHg. These findings suggest that the FC induced increase in CBF during exercise could not be explained only by change in SkBFface.

  18. Plasma volume expansion by albumin in cirrhosis. Relation to blood volume distribution, arterial compliance and severity of disease

    DEFF Research Database (Denmark)

    Brinch, Kim; Bendtsen, Flemming; Becker, Povl Ulrik

    2003-01-01

    /14/9) received an intravenous infusion of 40 g human serum albumin during a haemodynamic investigation. RESULTS: Whereas plasma- and blood volume increased by 23 and 15%, respectively (Pblood volume was found only in class A patients (+8%, P...BACKGROUND/AIMS: The aim of the study was to investigate the effect of a standard albumin load on blood volume distribution, arterial compliance, and the renin-angiotensin-aldosterone system in patients with different degrees of cirrhosis. METHODS: 31 patients with cirrhosis (Child classes A/B/C=8...... or class C patients (+2.7%, not significant (n.s.)). In contrast, arterial compliance only increased significantly in class C patients (+18%, PPlasma renin activity (PRA) decreased significantly in class C patients (-31%, P

  19. In vivo measurement of blood flow in a micro-scale stenosis model generated by laser photothermal blood coagulation.

    Science.gov (United States)

    Lee, Sang Joon; Ha, Ho Jin

    2013-04-01

    Blood flow in a stenosed vessel is one of the most important issues, because it is closely related to the outbreak of circulatory diseases. To overcome the technological limitations encountered in the haemodynamic studies using in vitro stenosis models, the authors induced a stenosed flow model in the extraembryonic vessels of a chicken embryo. Blood was coagulated by laser irradiation to artificially form a stenosis on the designated spot in a straight blood vessel. Owing to photothermal coagulation of red blood cells (RBCs), the blood is denatured and a stable blood coagulum is induced in the vessel. The blood coagulum adheres firmly and stably on the vessel wall without any size variation. It disturbs the on-coming blood flow significantly. To investigate the haemodynamic characteristics of the blood flow in the stenosed vessel, a micro particle image velocimetry technique was employed using RBCs as tracers to measure the spatial distributions of velocity vectors, streamlines and shear rate. The present simple modelling of in vivo stenosis would be useful for investigating the basic haemodynamic mechanisms underlying circulatory vascular diseases.

  20. Modelling of the Blood Coagulation Cascade in an In Vitro Flow System

    DEFF Research Database (Denmark)

    Andersen, Nina Marianne; Sørensen, Mads Peter; Efendiev, Messoud A.

    2010-01-01

    We derive a mathematical model of a part of the blood coagulation cascade set up in a perfusion experiment. Our purpose is to simulate the influence of blood flow and diffusion on the blood coagulation pathway. The resulting model consists of a system of partial differential equations taking...... and flow equations, which guarantee non negative concentrations at all times. The criteria is applied to the model of the blood coagulation cascade....

  1. VENOUS OCULAR BLOOD FLOW IN NORMAL TENSION AND HIGH TENSION GLAUCOMA

    Directory of Open Access Journals (Sweden)

    Natalia I Kurysheva

    2016-04-01

    Full Text Available Purpose: to study the eye’s venous blood flow and the correlation between clinical data and ocular blood flow in normal tension and high tension open angle glaucoma (POAG. Methods: Color Doppler imaging of arterial and venous blood flow was performed on 78 patients with normal tension glaucoma (NTG, 80 patients with high-pressure glaucoma (HPG and 60 control subjects. The statistical analysis included the calculation of the correlation between clinical data and ocular blood flow parameters, as well as Pearson’s correlation coefficient. The threshold P value for statistical significance was 0.05. Results: Ocular blood flow (both arterial and venous was significantly reduced in NTG and HTG, compared to the control group. While the arterial blood flow reduction was more significant in HTG than in NTG, a decrease in venous blood flow had a higher incidence in NTG. In contrast to the control group, POAG patients showed a correlation between clinical data and venous blood flow. The correlation was higher in NTG patients. Conclusions: The results obtained indicate the potential importance of venous blood flow in glaucoma pathogenesis, especially in NTG.

  2. Uterine artery Doppler and subendometrial blood flow in patients with unexplained recurrent miscarriage

    Directory of Open Access Journals (Sweden)

    Hala Abdel Wahab

    2011-09-01

    Conclusion: The presence of good uterine and endometrial blood flow is an important prerequisite for successful implantation and continuation of pregnancy as shown by higher uterine artery blood flow resistance and lower endometrial blood flow in recurrent miscarriage cases and those patients with unexplained RPL may have abnormalities in the uterine and endometrial blood flow. Despite these findings we could not find any cut off values that could predict the occurrence of miscarriage which may be attributed to small sample size and short period of follow up so larger prospective studies are needed aiming to confirm such results and reaching values that can accurately predict the occurrence of miscarriage.

  3. Cerebral blood flow changes during sodium-lactate-induced panic attacks

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, R.S.; Devous, M.D. Sr.; Rush, A.J.; Lane, L.; Bonte, F.J.

    1988-04-01

    Dynamic single-photon emission computed axial tomography (CAT) with inhaled xenon-133 was used to measure regional cerebral blood flow in 10 drug-free patients with DSM-III-diagnosed panic disorder and in five normal control subjects. All subjects underwent regional cerebral blood flow studies while at rest or during normal saline infusion and during sodium lactate infusion. Six of the 10 patients and none of the control subjects experienced lactate-induced panic attacks. Lactate infusion markedly raised hemispheric blood flow levels in both control subjects and patients who did not panic. Patients who did panic experienced either a minimal increase or a decrease in hemispheric blood flow.

  4. Forearm Skin Blood Flow After Kinesiology Taping in Healthy Soccer Players: An Exploratory Investigation

    National Research Council Canada - National Science Library

    Woodward, Kirsty A; Unnithan, Vish; Hopkins, Nicola D

    2015-01-01

    Kinesiology tape (KT) has become popular among athletes for both injury prevention and rehabilitation due to its reported therapeutic effects, including facilitation of lymphatic flow and enhanced peripheral blood flow...

  5. Effects of low power violet laser irradiation on red blood cells volume and erythrocyte sedimentation rate in human blood

    Science.gov (United States)

    Al Musawi, Mustafa S.; Jafaar, M. S.; Ahmed, Naser M.; Al-Gailani, B. T.; Suhaimi, Fatanah M.

    2017-08-01

    This study is designed in vitro to examine the effects of low power violet laser irradiation on some human blood samples rheological factors such as mean red blood cell volume (MCV) and erythrocyte sedimentation rate (ESR). Blood samples were collected into EDTA contained tubes and separated into two equal aliquots to be attended as irradiated and control. Samples were irradiated for 20, 30, 40 or 50 min with a laser of power 10 mW. The measurements were done directly after irradiation by applying westergen method and using a computerized hemtoanalyzer. The RBCs volume and ESR were decreased after irradiation for 40min by 0.44% and 6.7% respectively. It is possible to suggest that laser irradiation can reduction red blood cells volume because of the increased concentrations of free intracellular Ca+². The result shows that ESR reduction exposed to low power laser is mostly by reason of the effect of laser on composition of the plasma that finally affects in ESR of whole blood.

  6. Plasma volume and blood pressure regulation in hypertensive pregnancy

    NARCIS (Netherlands)

    Ganzevoort, Wessel; Rep, Annelies; Bonsel, Gouke J.; de Vries, Johanna I. P.; Wolf, Hans

    2004-01-01

    Background Pre-eclampsia is a multisystem disorder, peculiar to and frequent in human pregnancy. It remains a leading cause of maternal and neonatal morbidity and mortality. Hemodynamic disturbances are the most prominent features of the syndrome. Purpose To provide an overview of plasma volume

  7. In vivo vascular flow profiling combined with optical tweezers based blood routing

    Science.gov (United States)

    Meissner, Robert; Sugden, Wade W.; Siekmann, Arndt F.; Denz, Cornelia

    2017-07-01

    In vivo wall shear rate is quantified during zebrafish development using particle image velocimetry for biomedical diagnosis and modeling of artificial vessels. By using brightfield microscopy based high speed video tracking we can resolve single heart-beat cycles of blood flow in both space and time. Maximum blood flow velocities and wall shear rates are presented for zebrafish at two and three days post fertilization. By applying biocompatible optical tweezers as an Optical rail we present rerouting of red blood cells in vivo. With purely light-driven means we are able to compensate the lack of proper red blood cell blood flow in so far unperfused capillaries.

  8. Transcranial Doppler-determined change in posterior cerebral artery blood flow velocity does not reflect vertebral artery blood flow during exercise.

    Science.gov (United States)

    Washio, Takuro; Sasaki, Hiroyuki; Ogoh, Shigehiko

    2017-04-01

    We examined whether a change in posterior cerebral artery flow velocity (PCAv) reflected the posterior cerebral blood flow in healthy subjects during both static and dynamic exercise. PCAv and vertebral artery (VA) blood flow, as an index of posterior cerebral blood flow, were continuously measured during an exercise trial using transcranial Doppler (TCD) ultrasonography and Doppler ultrasound, respectively. Static handgrip exercise significantly increased both PCAv and VA blood flow. Increasing intensity of dynamic exercise further increased VA blood flow from moderate exercise, while PCAv decreased to almost resting level. During both static and dynamic exercise, the PCA cerebrovascular conductance (CVC) index significantly decreased from rest (static and high-intensity dynamic exercise, -11.5 ± 12.2% and -18.0 ± 16.8%, means ± SD, respectively) despite no change in the CVC of VA. These results indicate that vasoconstriction occurred at PCA but not VA during exercise-induced hypertension. This discrepancy in vascular response to exercise between PCA and VA may be due to different cerebral arterial characteristics. Therefore, to determine the effect of exercise on posterior cerebral circulation, at least, we need to carefully consider which cerebral artery to measure, regardless of exercise mode.NEW & NOTEWORTHY We examined whether transcranial Doppler-determined flow velocity in the posterior cerebral artery can be used as an index of cerebral blood flow during exercise. However, the changes in posterior cerebral artery flow velocity during exercise do not reflect vertebral artery blood flow. Copyright © 2017 the American Physiological Society.

  9. Numerical Modeling of Interstitial Fluid Flow Coupled with Blood Flow through a Remodeled Solid Tumor Microvascular Network.

    Directory of Open Access Journals (Sweden)

    M Soltani

    Full Text Available Modeling of interstitial fluid flow involves processes such as fluid diffusion, convective transport in extracellular matrix, and extravasation from blood vessels. To date, majority of microvascular flow modeling has been done at different levels and scales mostly on simple tumor shapes with their capillaries. However, with our proposed numerical model, more complex and realistic tumor shapes and capillary networks can be studied. Both blood flow through a capillary network, which is induced by a solid tumor, and fluid flow in tumor's surrounding tissue are formulated. First, governing equations of angiogenesis are implemented to specify the different domains for the network and interstitium. Then, governing equations for flow modeling are introduced for different domains. The conservation laws for mass and momentum (including continuity equation, Darcy's law for tissue, and simplified Navier-Stokes equation for blood flow through capillaries are used for simulating interstitial and intravascular flows and Starling's law is used for closing this system of equations and coupling the intravascular and extravascular flows. This is the first study of flow modeling in solid tumors to naturalistically couple intravascular and extravascular flow through a network. This network is generated by sprouting angiogenesis and consisting of one parent vessel connected to the network while taking into account the non-continuous behavior of blood, adaptability of capillary diameter to hemodynamics and metabolic stimuli, non-Newtonian blood flow, and phase separation of blood flow in capillary bifurcation. The incorporation of the outlined components beyond the previous models provides a more realistic prediction of interstitial fluid flow pattern in solid tumors and surrounding tissues. Results predict higher interstitial pressure, almost two times, for realistic model compared to the simplified model.

  10. Evaluation of oscillation-free fluid-porous interface treatments for segregated finite volume flow solvers

    NARCIS (Netherlands)

    Staniç, M.; Nordlund, M.; Frederix, E.M.A.; Kuczaj, Arkadiusz K.; Geurts, Bernardus J.

    2016-01-01

    The volume-averaged approach to simulate flow in porous media is often used because of its practicality and computational efficiency. Derivation of the volume-averaged porous flow equations introduces additional porous resistance terms to the momentum equation. These porous resistance terms create

  11. Improving left ventricular segmentation in four-dimensional flow MRI using intramodality image registration for cardiac blood flow analysis.

    Science.gov (United States)

    Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino

    2018-01-01

    Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. Blood flow restriction exercise in sprinters and endurance runners.

    Science.gov (United States)

    Takada, Shingo; Okita, Koichi; Suga, Tadashi; Omokawa, Masashi; Morita, Noriteru; Horiuchi, Masahiro; Kadoguchi, Tomoyasu; Takahashi, Masashige; Hirabayashi, Kagami; Yokota, Takashi; Kinugawa, Shintaro; Tsutsui, Hiroyuki

    2012-03-01

    We demonstrated that blood flow restriction (BFR) remarkably enhances muscular metabolic stress in resistance exercise, although there is a wide range of individual differences in the responses. It is possible that these differences could be due to training status and muscular physiological characteristics. We investigated intramuscular metabolic responses during low-intensity resistance exercise with BFR between two different types of track athletes. Twelve age-matched male track athletes (sprinter group, n = 6; endurance runner group, n = 6) were recruited and performed unilateral plantarflexion (30 repetitions per minute). The exercise protocols were as follows: low-intensity exercise at 20% of one-repetition maximum (1RM) (L), high-intensity exercise at 65% 1RM without BFR (1.3 times of systolic blood pressure), L with BFR for 2 min (L-BFR), and prolonged exercise time in L-BFR for 3 min (prolonged BFR). Metabolic stress, defined as phosphocreatine and intramuscular pH decrease, and muscle fiber recruitment were evaluated using P magnetic resonance spectroscopy. Endurance runners showed higher peak oxygen uptake and lower muscle strength than sprinters. Phosphocreatine decreases in endurance runners during exercise with BFR protocols were significantly greater than those in sprinters (P sprinters (P < 0.05). The changes in intramuscular pH and the incidence of fast-twitch fiber recruitment did not show a statistical difference between the two groups. Phosphocreatine decreases in L-BFR were significantly correlated with peak oxygen uptake (P < 0.05). The effects of low-intensity resistance exercise with BFR are greater in endurance runners according to higher aerobic capacity.

  13. PREDICTION OF BLOOD FLOW VELOCITY AND LEAFLET DEFORMATION VIA 2D MITRAL VALVE MODEL

    Directory of Open Access Journals (Sweden)

    M.A.H. Mohd Adib

    2012-06-01

    Full Text Available In the mitral valve, regional variations in structure and material properties combine to affect the biomechanics of the entire valve. From previous studies, we know that the mitral valve leaflet tissue is highly extensible. A two-dimensional model of the mitral valve was generated using an Arbitrary Lagrangian-Eulerian (ALE mesh. A simple approximation of the heart geometry was used and the valve dimensions were based on actual measurements made. Valve opening and closure was simulated using contact equations. The objective of this study was to investigate and predict flow and leaflet phenomena via a simple 2D mitral valve model based on the critical parameter of blood. Two stages of mitral valves analysis were investigated: the systolic and diastolic stages. The results show a linear correlation between the mitral valve leaflet rigidity and the volume of backflow. Additionally, the simulation predicted mitral valve leaflet displacement during closure, which agreed with the results of our previous data analysis and the results for blood flow velocity during systole condition through the mitral valve outlet, as reported in the medical literature. In conclusion, these computational techniques are very useful in the study of both degenerative valve disease and failure of prostheses and will be further developed to investigate heart valve failure and subsequent surgical repair.

  14. En face Doppler total retinal blood flow measurement with 70 kHz spectral optical coherence tomography

    Science.gov (United States)

    Tan, Ou; Liu, Gangjun; Liang, Liu; Gao, Simon S.; Pechauer, Alex D.; Jia, Yali; Huang, David

    2015-01-01

    Abstract. An automated algorithm was developed for total retinal blood flow (TRBF) using 70-kHz spectral optical coherence tomography (OCT). The OCT was calibrated for the transformation from Doppler shift to speed based on a flow phantom. The TRBF scan pattern contained five repeated volume scans (2×2  mm) obtained in 3 s and centered on central retinal vessels in the optic disc. The TRBF was calculated using an en face Doppler technique. For each retinal vein, blood flow was measured at an optimal plane where the calculated flow was maximized. The TRBF was calculated by summing flow in all veins. The algorithm tracked vascular branching so that either root or branch veins are summed, but never both. The TRBF in five repeated volumes were averaged to reduce variation due to cardiac cycle pulsation. Finally, the TRBF was corrected for eye length variation. Twelve healthy eyes and 12 glaucomatous eyes were enrolled to test the algorithm. The TRBF was 45.4±6.7  μl/min for healthy control and 34.7±7.6  μl/min for glaucomatous participants (p-value=0.01). The intravisit repeatability was 8.6% for healthy controls and 8.4% for glaucoma participants. The proposed automated method provided repeatable TRBF measurement. PMID:26062663

  15. Cu-blood flow model through a catheterized mild stenotic artery with a thrombosis.

    Science.gov (United States)

    Elnaqeeb, Thanaa; Mekheimer, Khaled S; Alghamdi, Felwah

    2016-12-01

    Copper nanoparticles blood flow analysis through a catheterized mild stenotic artery with a thrombosis is presented. The system of coupled governing equations are prescribed and then simplified under mild stenosis assumptions. The governing equations are solved exactly, and then expressions for temperature, axial velocity, stream function, wall shear stress and resistance impedance are obtained generally for metallic nanoparticles blood flow. Due to the importance of copper nanoparticles in biomedicine, the results for Cu-blood flow model are introduced. The effect of various pertinent flow and geometric parameters on copper-blood flow features in the stenotic region are illustrated and discussed through graphs for catheter and tube models. Blood trapping is introduced graphically for numerous flow parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Diet-induced changes in subcutaneous adipose tissue blood flow in man

    DEFF Research Database (Denmark)

    Simonsen, L; Bülow, J; Astrup, A

    1990-01-01