WorldWideScience

Sample records for voltage unbalances due

  1. Voltage Unbalance Compensation with Smart Three-phase Loads

    DEFF Research Database (Denmark)

    Douglass, Philip; Trintis, Ionut; Munk-Nielsen, Stig

    2016-01-01

    voltage, but it does not reduce the negative sequence voltage. The controller that uses phase-phase voltage as input eliminates negative sequence voltage, and reduces voltage deviations from the average to approximately half their initial value. Current unbalance is reduced when the voltage unbalance...... is caused by asymmetrical loads. These results suggest that the optimal algorithm to reduce system unbalance depends on which system parameter is most important: phase-neutral voltage unbalance, phase-phase voltage unbalance, or current unbalance....

  2. Voltage Unbalance Compensation with Smart Three-phase Loads

    DEFF Research Database (Denmark)

    Douglass, Philip; Trintis, Ionut; Munk-Nielsen, Stig

    2016-01-01

    This paper describes the design, proof-of-concept simulations and laboratory test of an algorithm for controlling active front-end rectifiers to reduce voltage unbalance. Using inputs of RMS voltage, the rectifier controller allocates load unevenly on its 3 phases to compensate for voltage unbala...... is caused by asymmetrical loads. These results suggest that the optimal algorithm to reduce system unbalance depends on which system parameter is most important: phase-neutral voltage unbalance, phase-phase voltage unbalance, or current unbalance....

  3. Secondary control for voltage unbalance compensation in an islanded microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza

    2011-01-01

    In this paper, the concept of secondary control is applied for voltage unbalance compensation in an islanded microgrid. The aim of the proposed control approach is to enhance the voltage quality at the point of common coupling (PCC). Unbalance compensation is achieved by proper control of distrib......In this paper, the concept of secondary control is applied for voltage unbalance compensation in an islanded microgrid. The aim of the proposed control approach is to enhance the voltage quality at the point of common coupling (PCC). Unbalance compensation is achieved by proper control...

  4. Power System Unbalance due to Railway Electrification

    DEFF Research Database (Denmark)

    Stamatopoulos, Athanasios; Vikelgaard, Henrik; Silva, Filipe Miguel Faria da

    2016-01-01

    The decision to electrify the main part of the Danish railway at the same time where the supply and generation of electrical power in Denmark moves to a more decentralized structure, raises concerns regarding the balanced and secure operation of the power grid. Adverse effects include, among others......, the lifetime reduction of rotating machines and the malfunction of HVDC converters. Toward this direction, this paper aims to review the challenges and mitigation solutions with respect to voltage unbalance, focusing on the conditions relevant to the electrification of the Danish railway....

  5. Approach to unbalance power active compensation under linear load unbalances and fundamental voltage asymmetries

    Energy Technology Data Exchange (ETDEWEB)

    Segui-Chilet, S.; Gimeno-Sales, F.J.; Orts, S.; Alcaniz, M.; Masot, R. [Instituto de Tecnologia Electrica - Grupo de Tecnologia Electronica, Universidad Politecnica de Valencia, Camino de Vera 14, 46022 Valencia (Spain); Garcera, G.; Figueres, E. [Departamento de Ingenieria Electronica, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)

    2007-09-15

    This paper proposes a new definition of the unbalance power that allows the selective compensation of inefficiencies caused by linear loads by means of a three-phase shunt active power compensator (APC). Symmetrical components of current and voltage are used to evaluate the unbalance power in these systems and to define the compensating currents. The instantaneous power flows with unbalanced linear loads connected to a three-phase electrical system are analyzed following the normal procedure used for the quantification of the reactive power. Equations to calculate the unbalance power and the effective apparent power are obtained from the analysis of the instantaneous power flows. The output currents of the selective APC are defined using the instantaneous unbalance power approach. Power quantities and APC compensating current are defined for IEEE Std. 1459 and for the instantaneous unbalance power approach. Two examples are used to compare the power quantities and the APC operation. The main effects of unbalanced linear load and of fundamental voltage asymmetries are analyzed. Simulations of a shunt APC emphasize the advantages of the calculation of the compensating currents based on the proposed instantaneous unbalance power approach. A comparison with the results obtained by calculation of the compensating currents based on IEEE Std. 1459 is carried out. A new power factor is also defined and compared with other conventional definitions. (author)

  6. Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza;

    2011-01-01

    active and reactive power controllers, virtual impedance loop and voltage and current controllers. The secondary level is designed to compensate the voltage unbalance at the load bus (LB) of the islanded microgrid. Also, restoration of LB voltage amplitude and microgrid frequency to the rated values...... is considered in the secondary level. These functions are achieved by proper control of distributed generators (DGs) interface converters. The presented simulation results show the effectiveness of the proposed control structure in compensating the voltage unbalance and restoring the voltage amplitude...

  7. Mitigation of Unbalanced Voltage Sags and Voltage Unbalance in CIGRE Low Voltage Distribution Network

    OpenAIRE

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar; Cecati, Carlo

    2013-01-01

    Any problem with voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM) etc. can be used to mitigate the voltage problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate unbalanced voltage sags and voltage unbalance in the CIGRE Low Voltage (LV) test network and net-works like this. The voltage unbala...

  8. A Direct Voltage Unbalance Compensation Strategy for Islanded Microgrids

    DEFF Research Database (Denmark)

    Zhao, Xin; Wu, Xiaohua; Meng, Lexuan

    2015-01-01

    In this paper, a control strategy with low bandwidth communications for paralleled three-phase inverters is proposed to achieve satisfactory voltage unbalance compensation. The proposed control algorithm mainly consists of voltage/current inner loop controllers, a droop controller, a selective......-leg inverters was tested in order to validate the proposed control strategy....

  9. Experimental evaluation of voltage unbalance compensation in an islanded microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza

    2011-01-01

    In this paper, a method for voltage unbalance compensation in an islanded microgrid based on the proper control of distributed generators (DGs) interface converter is proposed. In this method, active and reactive power control loops are considered to control the power sharing among the DGs. Also...

  10. Analysis of voltage unbalance effects on induction motors with open and closed slots

    Energy Technology Data Exchange (ETDEWEB)

    Donolo, Pablo, E-mail: pdonolo@gmail.co [Grupo de Electronica Aplicada, Fac. de Ingenieria, Universidad Nacional de Rio Cuarto, Ruta Nac. 36 Km 601 (X5804BYA), Rio Cuarto, Cordoba (Argentina); Bossio, Guillermo, E-mail: gbossio@ieee.or [Grupo de Electronica Aplicada, Fac. de Ingenieria, Universidad Nacional de Rio Cuarto, Ruta Nac. 36 Km 601 (X5804BYA), Rio Cuarto, Cordoba (Argentina); De Angelo, Cristian, E-mail: cdeangelo@ieee.or [Grupo de Electronica Aplicada, Fac. de Ingenieria, Universidad Nacional de Rio Cuarto, Ruta Nac. 36 Km 601 (X5804BYA), Rio Cuarto, Cordoba (Argentina)

    2011-05-15

    Research highlights: {yields} We study the increase of losses in the induction motor (IM) with voltage unbalance. {yields} We take into account the variations in the negative-sequence impedance of the rotor. {yields} We analyze the performance in IM with open and closed rotor slots. {yields} For both type of rotors, we get the derating factor for different levels of unbalance. {yields} IM with closed-slot are less affected by voltage unbalance than open-slot ones. -- Abstract: This paper aims to complement studies concerning the influence of voltage unbalance on the performance of induction motors. We use sequence equivalent circuits to determine the increase of losses in the induction motor. We take into account the dependence of the rotor negative-sequence reactance with the load state and the increase in rotor resistance with the negative-sequence currents. Variations in the negative-sequence impedance are related with the structural characteristics of the rotor. We analyze motors with open and closed rotor slots, because the impedance of rotors with closed slots grows considerably when the load is less than rated, producing lower negative-sequence currents and lower losses. Increased rotor impedance in closed slot motors protects these motors against problems due to unbalanced supply voltage. For both type of rotors, we analyze motor derating factor based on voltage unbalance and increases in total losses and rotor losses.

  11. Secondary Voltage Unbalance Compensation for Three-Phase Four-Wire Islanded Microgrids

    DEFF Research Database (Denmark)

    Tang, Fen; Zhou, Xiao; Meng, Lexuan;

    2014-01-01

    This paper proposes a secondary voltage unbalance control approach that compensate voltage unbalances in three-phase four-wire islanded microgrid systems. It is implemented in the secondary control level of the microgrid hierarchical control structure. By sending information through low...

  12. A comparative study of different transformer connections for railway power supply- mitigation of voltage unbalance

    DEFF Research Database (Denmark)

    Firat, Gurkan; Yang, Guangya; Ali Hussain Al-Ali, Haider

    2015-01-01

    The railway represents a large power consumer that can cause uneven loading of the phases in the high voltage grid. These unbalanced loads supplied by the utility may lead to voltage unbalance problems in the system and thereby affects the other consumers connected to the same network. It is fact...... that, voltage unbalance appears mainly as a result of unbalanced currents at the points of common coupling drawn by unevenly distributed loads. Because of a significant amount of negative sequence current injected to the system, the power system components will suffer from consequent negative effects...... such as overheating, additional losses of lines and transformers, interference with communication systems etc. This paper presents a comparative study of some transformer connections which commonly used in railway supplying AC traction loads, for voltage unbalance mitigations. Simulations for comparison...

  13. Voltage unbalance mitigation in LV networks using three-phase PV systems

    DEFF Research Database (Denmark)

    Garcia Bajo, Cristina; Hashemi Toghroljerdi, Seyedmostafa; Bækhøj Kjær, Søren;

    2015-01-01

    In this paper a new method is proposed to mitigate voltage unbalance caused by single-phase solar inverters in low voltage (LV) networks. The method is based on uneven reactive power absorption and injection by three-phase solar inverters. Independent control of each phase is performed to achieve...

  14. Effects of voltage unbalance and system harmonics on the performance of doubly fed induction wind generators

    Science.gov (United States)

    Kiani, Morgan Mozhgan

    Inherent difficulties in management of electric power in the presence of an increasing demand for more energy, non-conventional loads such as digital appliances, and non-sustainable imported fossil fuels has initiated a multi-folded effort by many countries to restructure the way electric energy is generated, dispatched, and consumed. Smart power grid is the manifestation of many technologies that would eventually transforms the existing power grid into a more flexible, fault resilient, and intelligent system. Integration of distributed renewable energy sources plays a central role in successful implementation of this transformation. Among the renewable options, wind energy harvesting offers superior engineering and economical incentives with minimal environmental impacts. Doubly fed induction generators (DFIG) have turned into a serious contender for wind energy generators due to their flexibility in control of active and reactive power with minimal silicon loss. Significant presence of voltage unbalance and system harmonics in finite inertia transmission lines can potentially undermine the reliability of these wind generators. The present dissertation has investigated the impacts of system unbalances and harmonics on the performance of the DFIG. Our investigation indicates that these effects can result in an undesirable undulation in the rotor shaft which can potentially invoke mechanical resonance, thereby causing catastrophic damages to the installations and the power grid. In order to remedy the above issue, a control solution for real time monitoring of the system unbalance and optimal excitation of the three phase rotor currents in a DFIG is offered. The optimal rotor currents will create appropriate components of the magneto-motive force in the airgap that will actively compensate the undesirable magnetic field originated by the stator windings. Due to the iterative nature of the optimization procedure, field reconstruction method has been incorporated

  15. Distributed Voltage Unbalance Compensation in Islanded Microgrids by Using Dynamic-Consensus-Algorithm

    DEFF Research Database (Denmark)

    Meng, Lexuan; Zhao, Xin; Tang, Fen;

    2016-01-01

    In islanded microgrids (MGs), distributed generators (DGs) can be employed as distributed compensators for improving the power quality in the consumer side. Two-level hierarchical control can be used for voltage unbalance compensation. Primary level, consisting of droop control and virtual...... impedance, can be applied to help the positive sequence active and reactive power sharing. Secondary level is used to assist voltage unbalance compensation. However, if distribution line differences are considered, the negative sequence current cannot be well shared among DGs. In order to overcome...

  16. Secondary Control Scheme for Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2012-01-01

    The concept of microgrid hierarchical control is presented recently. In this paper, a hierarchical scheme is proposed which includes primary and secondary control levels. The primary level comprises distributed generators (DGs) local controllers. The local controllers mainly consist of power......, voltage and current controllers, and virtual impedance control loop. The central secondary controller is designed to manage the compensation of voltage unbalance at the point of common coupling (PCC) in an islanded microgrid. Unbalance compensation is achieved by sending proper control signals to the DGs...

  17. Impacts of Light Rail Transit Tram on the Voltage and Unbalance of the Distribution System

    Directory of Open Access Journals (Sweden)

    Cheng-Ting Hsu

    2013-01-01

    Full Text Available This paper presents the three-phase voltage and unbalance analysis for the distribution system with the loading of a light rail transit (LRT tram. To investigate the dynamic responses of the system voltage and current, this paper adopts the Alternative Transients Program (ATP software to model and simulate a multigrounded four-wire distribution system with an LRT loading. Two different definitions about unbalance are used to evaluate the problem. In this paper, the traction supply substation (TSS with a single-phase transformer configuration is designed first for providing the electric power to the trams of LRT. However, it may result in the significant neutral line current and unbalance phenomenon to deteriorate the power quality of the distribution system. A Le-Blanc connection transformer in the TSS is therefore proposed to solve the problems.

  18. Voltage Unbalance and Harmonic Compensation in Microgrids by Cooperation of Distributed Generators and Active Power Filters

    DEFF Research Database (Denmark)

    Hashempour, Mohammad M.; Savaghebi, Mehdi; Quintero, Juan Carlos Vasquez

    2016-01-01

    , selective virtual impedance and voltage/current regulators. Based on the secondary control, at first voltage harmonic compensation and voltage unbalance compensation of point of common coupling (PCC), that might includes sensitive loads, is carried out by DGs. Voltage compensation of PCC by DGs may cause...... severe voltage distortion at DGs terminals. Thus, the coordinated control is used to mitigate the voltage distortion to the defined maximum allowable value at DGs terminals. Evaluation of the proposed hierarchical control is carried out by a simulation study....

  19. Tertiary Control of Voltage Unbalance Compensation for Optimal Power Quality in Islanded Microgrids

    DEFF Research Database (Denmark)

    Meng, Lexuan; Tang, Fen; Savaghebi, Mehdi;

    2014-01-01

    the voltage unbalance limits in local buses and DG terminals. This method realizes multi-power-quality-level control in a multi-bus islanded system by optimally utilizing DGs as distributed compensators and saves the investment for additional compensation equipment. Hardware-in-the-loop results demonstrate...

  20. Tertiary control of voltage unbalance compensation for optimal power quality in islanded microgrids

    DEFF Research Database (Denmark)

    Meng, Lexuan; Tang, Fen; Savaghebi, Mehdi

    2016-01-01

    DG considering the voltage unbalance limits in local buses and DG terminals. This method realizes multi-power-quality-level control in a multi-bus islanded system by optimally utilizing DGs as distributed compensators and saves the investment for additional compensation equipment. Hardware-in...

  1. Autonomous Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2013-01-01

    Recently, there is an increasing interest in using distributed generators (DGs) not only to inject power into the grid, but also to enhance the power quality. In this paper, a stationary-frame control method for voltage unbalance compensation in an islanded microgrid is proposed. This method...

  2. Analytical Disturbance Modeling of a Flywheel Due to Statically and Dynamically Unbalances

    Directory of Open Access Journals (Sweden)

    Amir karimian

    2012-06-01

    Full Text Available Unbalances in rotational machines can't delete completely somehow for precise mechanism it is necessary to control vibration due to such disturbances. In this research two common disturbance resources (dynamically and statically unbalances for a flywheel on a rigid shaft modeled and energy methods used to derive equation of motion in five degrees of freedom. Equations linearized due to small vibration and disturbance forces and torques achieved. The model use to define design criteria for accepted level of unbalances in precise machines like real flywheel with known parameters used in a control system of a satellite.

  3. Analytical Disturbance Modeling of a Flywheel Due to Statically and Dynamically Unbalances

    OpenAIRE

    Amir karimian; Alireza aghalari

    2012-01-01

    Unbalances in rotational machines can't delete completely somehow for precise mechanism it is necessary to control vibration due to such disturbances. In this research two common disturbance resources (dynamically and statically unbalances) for a flywheel on a rigid shaft modeled and energy methods used to derive equation of motion in five degrees of freedom. Equations linearized due to small vibration and disturbance forces and torques achieved. The model use to define design criteria for ac...

  4. SiC heat pump converters with support for voltage unbalance in distribution grids

    DEFF Research Database (Denmark)

    Trintis, Ionut; Douglass, Philip; Maheshwari, Ramkrishan

    2015-01-01

    This paper studies the impact of involving the demand side of the LV grid into the grid conditioning process. Heat pumps are distribution loads with a substation capacity increase in the last years, with expectancy of growth in the coming years. Controlling the loads is the first step...... in the transition to smart grids, and heat pumps are to be the first promising smart loads. They can be used for load shedding but also for unbalance compensation purposes. When they are equipped with a back to back compressor drive and a proper control strategy, grid support can be provided to reduce the negative...... sequence component in the voltage at the installation point. Two control strategies are proposed and investigated experimentally on a SiC heat pump converter prototype....

  5. Investigation of Voltage Unbalance Problems In Electric Arc Furnace Operation Model

    Directory of Open Access Journals (Sweden)

    Yacine DJEGHADER

    2013-06-01

    Full Text Available In modern steel industry, Electric Arc Furnaces are widely used for iron and scarp melting. The operation of electric arc furnace causes many power quality problems such as harmonics, unbalanced voltage and flicker. The factors that affect Electric arc furnace operation are the melting or refining materials, melting stage, electrodes position (arc length, electrode arm control and short circuit power of the feeder, so, arc voltages, current and power are defined as a nonlinear function of arc length. This study focuses on investigation of unbalanced voltage due to Electrics Arc Furnace operation mode. The simulation results show the major problem of unbalanced voltage affecting secondary of furnace transformer is caused by the different continues movement of electrodes.

  6. Parametric Identification of a Dynamic Foundation Model of a Rotary Machine Using Response Data Due to Unknown Unbalances

    Directory of Open Access Journals (Sweden)

    Uwe Prells

    2000-01-01

    Full Text Available The estimation of a model of the foundation of a rotary machine has been recently attempted by using the difference between two sets of response data at some of the bearing locations from two consecutive rundowns of the machine, with and without known unbalance weights at certain positions on the two balance discs of each rotor respectively. However, it would be a great advantage to be able to perform the estimation with a single rundown. Due to practical restrictions in performing such tests (accessibility, costs etc., there are cases in which data for only one rundown are available. In this case, the unbalance configuration is unknown and has, therefore, to be estimated, in addition to the unknown foundation model. Due to the special form of the unbalance force, this overall inverse problem can be solved by eliminating the unbalance configuration from the model estimation process. The remaining equation to estimate the foundation model consists of the projection of the response data, where the associated projector depends on the foundation model parameter. First results using the method, applied to a laboratory test rig and to a commercial turbo-generator, are presented.

  7. 非线性负荷条件下的电压不平衡度探讨%Study on Voltage Unbalance Factor under Nonlinear Load

    Institute of Scientific and Technical Information of China (English)

    吕强; 徐晔; 王金全; 宋鹏超

    2013-01-01

    Damages caused by the unbalance of harmonic voltage in a low-voltage distribution system are discussed, the application principle of the symmetrical component method based on harmonics is analyzed; taking into account the regulations on voltage unbalance factor specified in national standard, the definition of the comprehensive unbalance factor of negative-sequence voltage and that of zero-sequence voltage are studied; the correctness of the theoretical analysis is proved by experiments; and the necessity of considering the unbalance of the harmonic voltage under nonlinear load is revealed through analysis.%阐述低压配电系统中谐波电压不平衡带来的危害,分析对称分量法在谐波条件下的应用原理;针对国家标准对电压不平衡度的规定,探讨负序电压综合不平衡度与零序电压综合不平衡度的定义;用实验证明理论分析的正确性;通过分析指出非线性负荷条件下考虑谐波电压不平衡的必要性。

  8. Impact of plug-in electric vehicles on voltage unbalance in ...

    African Journals Online (AJOL)

    DR OKE

    contributors of carbon dioxides, where the passenger vehicles account for half of the ... This study also presented that PEV charging in the low-voltage system can cause .... The summary information of EV connection are shown as Table 1.

  9. Improved direct power control of a grid-connected voltage source converter during network unbalance

    Institute of Scientific and Technical Information of China (English)

    Peng ZHOU; Wei ZHANG; Yi-kang HE; Rong ZENG

    2010-01-01

    This paper deals with an improved direct power control(DPC)strategy for the pulse width modulation(PWM)voltage source converter(VSC)under unbalanced grid voltage conditions.In order to provide enhanced control performance for the VSC,the resonant controllers tuned at the double grid frequency are applied in the DPC design to eliminate the power pulsations and dc link voltage ripples produced by the transient unbalanced grid faults.In this way,the output power and dc link voltage of the VSC can be directly regulated without positive and negative sequential decomposition.As a result,and as has been verified by experiment,the proposed method can provide fast dynamic response with easy implementation.

  10. Investigation of Voltage Unbalance Problems In Electric Arc Furnace Operation Model

    OpenAIRE

    Yacine DJEGHADER; Hocine LABAR

    2013-01-01

    In modern steel industry, Electric Arc Furnaces are widely used for iron and scarp melting. The operation of electric arc furnace causes many power quality problems such as harmonics, unbalanced voltage and flicker. The factors that affect Electric arc furnace operation are the melting or refining materials, melting stage, electrodes position (arc length), electrode arm control and short circuit power of the feeder, so, arc voltages, current and power are defined as a nonlinear function of ar...

  11. UPQC Controlled Capable Of Mitigating Unbalance In Source Voltage And Load Current

    Directory of Open Access Journals (Sweden)

    B. Santhosh Kumar

    2013-11-01

    Full Text Available This paper reports the development of a laboratory prototype of a fully digital DSP-controlled 12-kVA unified power quality conditioner (UPQC, capable of compensating for both the supply voltage and the load current imperfections. A fully digital controller based on the TMS320F2812 DSP platform is implemented for the reference generation as well as control purposes. The delay problem in the digital controller is overcome by application of a fast DSP, a compact control technique and proper flow of control steps in the DSP software. A phase-locked loop- less software grid synchronization method has been implemented for the effective operation of the UPQC under conditions of grid frequency variation. A sequence-based compensation strategy has been developed to compensate for balanced and unbalanced sags while accommodating the fact that the voltage injection capability of the UPQC is limited. The prototype UPQC power circuit, control features, and control algorithm along with experimental results are presented in this paper.

  12. Dynamic Consensus Algorithm based Distributed Unbalance Compensation in Islanded Microgrids

    DEFF Research Database (Denmark)

    Meng, Lexuan; Zhao, Xin; Firoozabadi, Mehdi Savaghebi;

    2015-01-01

    In islanded microgrids (MG), distributed generators (DG) can be employed as distributed compensators for improving the power quality (voltage unbalance and harmonics) in consumer side. Hierarchical control is usually applied with different control levels differentiated. In case of voltage unbalance...... compensation, droop control and virtual impedance can be applied in primary control to help the positive sequence active and reactive power sharing. Secondary control is used to assist voltage unbalance compensation. However, if transmission line differences are considered, the negative sequence current cannot...

  13. Unbalance on power systems: a general review

    Energy Technology Data Exchange (ETDEWEB)

    Reineri, Claudio A.; Gomez Targarona, Juan C.

    2009-07-01

    A general revision of different aspects in relation to the voltage unbalance in electric power systems is presented, that should necessarily be deeply known by technical operators and designers of facilities, installations, and electric equipment. Dissimilar unbalance definitions, unbalance measurement methods, their quantification and the interpretation of such magnitudes are revised. The causes of the unbalances in electric power systems were described and analyzed. The effects on power systems are also studied, specially those that have influence on: system operability, lost of efficiency of the three phase system and their impact in the definitions of traditional power. Similarly is studied the unbalance effect on certain loads, in particular: three-phase motors, power electronics and ASD's. Also methods to locate the origin of these problems, as well as the different normative or standards, and possible methods to mitigate their effects are deeply detailed. It is concluded in the necessity to deepen the study of the power system unbalance, because numerous non resolved aspects still exist whose solution requires of a deep knowledge on the part of the involved professionals. (author)

  14. Analysis on Voltage Unbalance of Auxiliary Transformer in Fangjiashan Nuclear Power Project and Corresponding Countermeasures%方家山核电工程辅助变压器电压不平衡的分析与对策

    Institute of Scientific and Technical Information of China (English)

    谢金平

    2012-01-01

    To analyze the voltage unbalance of auxiliary transformer under no-load operation, firstly the radial distributed capacitances of windings in the transformer are equivalently converted to concentrated capacitances at winding terminals and those between winding terminals by energy method, and it is found that the directly grounding of phase C in the balancing windings of the transformer leads to the unbalance of three-phase ground capacitances at low-voltage side of the transformer as well as the mutual capacitances between low-voltage windings and balancing windings; then a no-load circuit model of the transformer, in which the concentrated capacitance parameters are considered, is built by Matlab, and the simulation of no-load closing is performed. Simulation results show that three-phase ground capacitances at low-voltage side of the transformer are seriously unbalanced; finally technical countermeasures to solve the voltage unbalance are given.%为分析辅助变压器空载运行电压不平衡的现象,首先应用能量法将变压器各绕组的径向分布电容参数等效折算为各绕组端部和端部间的集中电容参数,发现由于变压器平衡绕组的C相直接接地,导致变压器低压侧三相对地电容不平衡,并且低压绕组与平衡绕组的互电容也不平衡.然后,应用Matlab建立了考虑集中电容参数的变压器空载电路模型,并进行空载合闸仿真试验,仿真试验结果表明变压器三相对地电压严重不平衡.最后,给出了解决电压不平衡问题的技术措施.

  15. 500kV主变低压三相对地电压不平衡的分析与处理%Analysis and Treatment of Voltage Unbalance of Three Phases to Earch in 500kV Main Transformer LV Side

    Institute of Scientific and Technical Information of China (English)

    欧阳旭东; 彭发东; 潘玉华

    2012-01-01

    分析了主变三相对地电压不平衡的原因,并通过仿真计算进行了验证。%The reasons of the voltage unbalance of three phases to earth in main transformer are analyzed. The result is verified with simulation and calculation.

  16. Design of computerized unbalance measuring system

    Energy Technology Data Exchange (ETDEWEB)

    Karunakara, K.; Nambudiri, P.V.V.; Aradhya, S.; Kumar, E.M.; Channakeshava [Central Power Research Inst., Bangalore (India)

    1995-12-31

    In complex network, the connected loads may be of single phase or three phase. Increased trend of traction loads, Arc furnace load and thyristor devices necessitates check for voltage quality. Harmonics, flicker and unbalance are some of the factors influencing the voltage quality. Evaluation of voltage quality and applying correction, if required, are to be made depending upon the situation prevailing in the system. Under certain load conditions like arc furnace, traction and thyristor devices, the unbalance factor may vary every few cycles and for the unbalance correction, devices like static Var compensator (SVC) have to be used. These correcting devices have some time lag to effect corrections, thus measurement based on short time information will not give the true picture. To avoid erroneous conclusions from the short term data, an instrument based on an integrated value over fairly long duration was designed and fabricated by CPRI. This paper discusses about the design and calibration of the instrument and presents typical measured data on an electrical system by using this instrument.

  17. Análisis de eficiencia de motores asincrónicos en presencia de desbalances y armónicos en la tensión: Efficiency analysis of induction motors in the presence of harmonics and unbalance voltage

    Directory of Open Access Journals (Sweden)

    Vladimir Sousa Santos

    2013-06-01

    Full Text Available En los sistemas eléctricos de potencia es muy común encontrar problemas de calidad de la energía. La circulación de armónicos de tiempo en las redes de suministro eléctrico industrial junto al desbalance de tensión, afecta considerablemente el funcionamiento de los motores asincrónicos trifásicos y dificulta su caracterización energética. Existen diferentes métodos in situ para la estimación de la eficiencia de los motores. Sin embargo, ninguno ha sido lo suficientemente preciso para el análisis bajo la influencia de armónicos, desviaciones y desbalance de tensión. En este trabajo se presenta un procedimiento basado en los circuitos equivalentes, con segregación de pérdidas y empleando un Algoritmo de Forraje Bacterial (AFB, que permite determinar en condiciones de campo y con baja invasividad, la eficiencia energética de motores asincrónicos trabajando en las condiciones señaladas. El método se probó satisfactoriamente en un motor de 1,5 kW alimentado con niveles significativos de desbalance y armónicos de tensión.In electric supply systems it is very common to find problems of power quality. The time harmonic flow in industrial electrical grids with voltage deviations and unbalance, significantly affects three phase induction motor operation and makes difficult energy characterization. There are different methods for in situ estimation of motors efficiency. However, none of them have been sufficiently precise for the analysis under non-sinusoidal, deviated and unbalanced voltage conditions. This paper presents a method based on the equivalent circuits, with losses segregation and using Bacterial Foraging Algorithm (BFA. It allows determining under field conditions and low invasiveness, energy efficiency of induction motors operating under the before mentioned conditions. This method was tested successfully on a 1,5 kW motor, fed with significant levels of unbalance and voltage harmonics.

  18. Análisis de eficiencia de motores asincrónicos en presencia de desbalances y armónicos en la tensión; Efficiency analysis of induction motors in the presence of harmonics and unbalance voltage

    Directory of Open Access Journals (Sweden)

    Vladimir Sousa Santos

    2013-06-01

    Full Text Available En los sistemas eléctricos de potencia es muy común encontrar problemas de calidad de la energía. La circulación de armónicos de tiempo en las redes de suministro eléctrico industrial junto al desbalance de tensión, afecta considerablemente el funcionamiento de los motores asincrónicos trifásicos y dificulta su caracterización energética. Existen diferentes métodos in situ para la estimación de la eficiencia de los motores. Sin embargo, ninguno ha sido lo suficientemente preciso para el análisis bajo la influencia de armónicos, desviaciones y desbalance de tensión. En este trabajo se presenta un procedimiento basado en los circuitos equivalentes, con segregación de pérdidas y empleando un Algoritmo de Forraje Bacterial (AFB, que permite determinar en condiciones de campo y con baja invasividad, la eficiencia energética de motores asincrónicos trabajando en las condiciones señaladas. El método se probó satisfactoriamente en un motor de 1,5 kW alimentado con niveles significativos de desbalance y armónicos de tensión.  In electric supply systems it is very common to find problems of power quality. The time harmonic flow in industrial electrical grids with voltage deviations and unbalance, significantly affects three phase induction motor operation and makes difficult energy characterization. There are different methods for in situ estimation of motors efficiency. However, none of them have been sufficiently precise for the analysis under non-sinusoidal, deviated and unbalanced voltage conditions. This paper presents a method based on the equivalent circuits, with losses segregation and using Bacterial Foraging Algorithm (BFA. It allows determining under field conditions and low invasiveness, energy efficiency of induction motors operating under the before mentioned conditions. This method was tested successfully on a 1,5 kW motor, fed with significant levels of unbalance and voltage harmonics.

  19. 不同负载工况下牵引变对电网电压不平衡的影响%Research on the influence of traction transformer in different load conditions on voltage unbalance in power supply system

    Institute of Scientific and Technical Information of China (English)

    杨申浩; 李凤婷

    2016-01-01

    In view of the unbalanced voltage problem in power system caused by electrified railway accessing to public substation,A 36-node grid test system and a variety of traction transformers were established on the platform of PSCAD,and the propagation condition of unbalanced voltage caused by electrified railway was analyzed.The voltage unbalance effect on the power system when it connecting traction transformers with balanced or unbalanced load under the condition of alternation commutation phase was researched.The study finds that the rational deployment of traction load can reduce the VUF of PCC less than 2%.The research result of simulation analysis provides theoretical support and engineering application value for transformer selection and load deployment.%针对电气化铁路接入公用变电站造成供电系统电压不平衡的问题,在PSCAD平台上建立了各种牵引变压器模型及36节点的电网测试系统,分析了电气化铁路引起的电压不平衡在系统中的传播情况;研究了轮流换相的条件下多台牵引变接入对称、不对称负载时对电网电压不平衡的影响;研究发现合理调配牵引变负载能使PCC点电压不平衡度低于2%。研究结果可为牵引变的选型和负载的合理调配提供理论支撑,具有工程应用价值。

  20. Caracterización de datos de desbalance de tensión en el suministro eléctrico industrial; Voltage Unbalance Assesment at Industrial Power Systems

    Directory of Open Access Journals (Sweden)

    Julio R Gómez Sarduy

    2011-02-01

    Full Text Available En este trabajo se abordan aspectos probabilísticos relacionados con el desbalance de tensión en una red desuministro eléctrico industrial donde predominan cargas trifásicas. Se muestra el perfil de desbalance detensión en diferentes subestaciones industriales, describiendo los datos registrados en términos estadísticos.Se muestra la necesidad de considerar este tipo de deterioro de la calidad de la energía  en diversos análisisoperacionales relacionados con el comportamiento en estado estable de los motores asincrónicos. One of the goals of parameter identification in asynchronous motors is efficiency evaluation in field conditions.According to the equivalent circuit method, knowing the parameters of the Park circuit in the operating rangeof the machine, adapted to   the power quality of field conditions, corresponding calculation are made. Inunbalanced voltage condition, there are some complexities because there are two sets of parameters belongingto the positive and negative sequence networks differing fundamentally in the rotor circuit. This paper, with theapplication of genetic algorithm; (GA , a new approach is proposed to identified the parameters of bothsequences combining the powerful proprieties  of GA with  one initial vector of parameters that allows reducethe search time without needs special proofs of some complexity that in field conditions are very expensiveor impossible to do.

  1. Fuzzy Bang-Bang Control Scheme of USSC for Voltage Sag Mitigation Due to Short Circuits and Induction Motor Starting in Distribution System

    Directory of Open Access Journals (Sweden)

    Mohammad Mohammadi

    2014-12-01

    Full Text Available Unified series shunt compensator (USSC has been widely used to mitigate various power quality disturbances in distribution network. The USSC is almost similar to the UPFC, but the only differences are that the UPFC inverters are in shunt series connection and used in transmission systems whereas the USSC inverters are in series-shunt connection and used in distribution systems. USSC, it is possible to compensate a different power quality problem as compared to DSTATCOM and DVR. It is noted that, mitigated load voltage by the DVR is lower than mitigated value obtained by USSC. In other words the USSC can mitigate voltage sag better in compared to DVR and D-STATCOM. Also in case of voltage flicker, unbalance and harmonics elimination it is much effective.  Similarly, D-STATCOM is unable to control power flow.  It is seen that the proposed USSC can mitigate variety of power quality (PQ problems. Hence due to multi capability of USSC in power quality improvement, this paper presents the scheme based on fuzzy bang-bang control for USSC. Using Fuzzy Logic Control (FLC based on bang-bang control; the USSC will contribute to improve voltage sag without deteriorating the effect of the other compensating devices.

  2. Centrifugal unbalance detection system

    Science.gov (United States)

    Cordaro, Joseph V.; Reeves, George; Mets, Michael

    2002-01-01

    A system consisting of an accelerometer sensor attached to a centrifuge enclosure for sensing vibrations and outputting a signal in the form of a sine wave with an amplitude and frequency that is passed through a pre-amp to convert it to a voltage signal, a low pass filter for removing extraneous noise, an A/D converter and a processor and algorithm for operating on the signal, whereby the algorithm interprets the amplitude and frequency associated with the signal and once an amplitude threshold has been exceeded the algorithm begins to count cycles during a predetermined time period and if a given number of complete cycles exceeds the frequency threshold during the predetermined time period, the system shuts down the centrifuge.

  3. [Fatal electric arc accidents due to high voltage].

    Science.gov (United States)

    Strauch, Hansjürg; Wirth, Ingo

    2004-01-01

    The frequency of electric arc accidents has been successfully reduced owing to preventive measures taken by the professional association. However, the risk of accidents has continued to exist in private setting. Three fatal electric arc accidents caused by high voltage are reported with reference to the autopsy findings.

  4. Break Cohesion of Metal Contacts due to Voltage Bias

    Institute of Scientific and Technical Information of China (English)

    LI Yu-Xian

    2006-01-01

    @@ The instability of metal point contacts under voltage bias is calculated based on scattering theory. When the bias is applied, the transport channels will be closed and the chemical bonds will be broken, which modify the cohesive force of the point contact.

  5. Unbalance Force Analysis of Primary Pump Shaft in PGSFR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sungkyun; Koo, Gyeonghoi [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In this paper, rotor-dynamic characteristics for the primary pump shaft were obtained. On the basis of the results, we decided to almost double the shaft diameter. By virtue of this design change, the revised design can be satisfied with the critical speed design criteria as well as can decrease a number of support bearings. In the results of unbalance analysis, it was figured that the maximum bearing deflections and loads are within the design criteria. All rotating shafts, even in the absence of external loads, have always eccentric distance due to the manufacturing deviations, material defects, and installation error. This unbalance mass resulting in the eccentric distance of the rotating structure causes resonance at critical speeds. The resonance is the state at which the harmonic loads are excited at their natural frequencies causing shafts to vibrate excessively. This vibration of large amplitude causes shafts to bend and twists significantly and leads to permanent failure. Hence, the determination of these rotor-dynamic characteristics of rotating shaft in the mechanical design stage is much important. In this paper following issues are addressed: - Describe how to calculate the unbalance force. - Predict the natural frequency variations and identify critical speeds within or near the operating speed range of a shaft for consideration of the unbalance bearing stiffness and damping. - Determine the available support positions of a pump shaft to avoid resonance within operating speed. - Perform an unbalance response analysis of a shaft in order to calculate shaft displacement and quantify the forces acting on the shaft support that are caused due to shaft unbalance.

  6. Rotor Unbalance Estimation with Reduced Number of Sensors

    Directory of Open Access Journals (Sweden)

    Sami M. Ibn Shamsah

    2016-10-01

    Full Text Available The most common cause of the excessive vibration in rotating machines is the rotor mass unbalance. If a machine vibration due to mass unbalance exceeds the alarm limits, then it may lead to machine failure. Therefore, rotating machines should be regularly checked to ensure that they are properly balanced. Currently, industries use the influence coefficient (IC balancing technique for in situ machine balancing. The accepted practice is to use the vibration measurements in both vertical and horizontal directions at the machine-bearing pedestals together with the tachometer signal to estimate the machine rotor unbalance (both mass and phase angle. It is generally believed that the use of the machine vibration measurements in the vertical and horizontal directions represents better machine dynamics, and hence the estimated unbalance is likely to be more accurate. However, this paper applies the same concept of the IC method but with a reduced number of vibration sensors (one sensor per bearing pedestal at 45° instead of two sensors at the vertical and horizontal directions. The use of one sensor per bearing pedestal at 45° from both vertical and horizontal directions is likely to have responses from both directions. The reduction in the number of sensors by half will definitely save the instruments and their maintenance cost and reduce the computational effort in the signal processing significantly. The proposed concept is applied on a small-size laboratory rig with two balancing planes. The paper presents the unbalance estimations by using the measured vibration responses in both the vertical and horizontal directions simultaneously and using vibration responses measured at 45°.

  7. Investigation of Power Factor on Harmonic Effect due to Types of Voltage Source

    Directory of Open Access Journals (Sweden)

    C.B. Risnidar

    2011-01-01

    Full Text Available This paper discussed about power factor on harmonic effect due to types of voltage source. Usually, the voltage source is sinusoidal. But in actual condition the load that has voltage sources through the elements where the output voltage of element as input to load is not pure sinusoidal, for example at Power of Common Coupling (PCC between transformer and linear load and nonlinear load. The research has been done with Schhafner Power Quality Analyzer and was focused to power factor (p.f., Total Harmonic Distortion (THD, and harmonic energy losses cost from measurement where load is Induction motor and Adjustable Speed Drive (ASD. As voltage source in this research are sine wave, square wave and combinations of 3rd, 5th and 7th harmonic order like harmonic 313, and harmonic 357.

  8. The Impact of Grid Unbalances on the Reliability of DC-link Capacitors in a Motor Drive

    DEFF Research Database (Denmark)

    Wang, Huai; Davari, Pooya; Kumar, Dinesh

    2017-01-01

    DC-link capacitor is one of the reliability-critical components in motor drive applications, which contributes to a considerable cost, size and failure. Its reliability performance depends on both inherent physical strength and external loading. The grid unbalances could alter the electro......-thermal stresses of key components in a motor drive. Therefore, this digest investigates the impact of grid voltage amplitude and phase unbalances on the lifetime of DC-link capacitors used in a standard three-phase motor drive. The theoretical stress models and experimental measurements of the capacitor voltages...... and ripple currents are presented. The relationship between the DC-link capacitor lifetime and the level of unbalances and loads are discussed based on a 7.5 kW motor drive system. The results serve as a guideline to size the DC-link capacitors to be robust enough at the presence of grid unbalance conditions....

  9. Investigation of Harmonic Characteristics in Printer due to Different Types of Voltage Source

    Directory of Open Access Journals (Sweden)

    C. Risnidar

    2012-01-01

    Full Text Available This paper discusses about harmonic characteristics due to different types of voltage sources. Usually, the voltage source is sinusoidal. But in actual condition the load that receives voltage sources through the elements where the output voltage of element as input to the load is not pure sinusoidal, for example voltage source at Power of Common Coupling (PCC between transformer and linear load and nonlinear load. This research has been done  with Schhafner Power Quality Analyzer and PM300 Power Quality Analyzer, was focused to all harmonic characteristics as power, voltage, current, power factor (p.f., Harmonic Distortion, and harmonic energy losses cost. The load is printer because the printer is one of electronic device causes harmonics. The voltage sources in this research are sine wave, triangle wave and harmonic order combinations of 3rd, 5th and 9th. Why this research discuses voltage source for Harmonic order 3rd, 5th and 9th and don not combination of 3rd, 5th and 7th, because the combination 3rd, 5th and 9th is more complicated then combination of 3rd, 5th and 7th.

  10. Voltage Swells Improvement in Low Voltage Network Using Dynamic Voltage Restorer

    Directory of Open Access Journals (Sweden)

    R. Omar

    2011-01-01

    Full Text Available Problem statement: Voltage disturbances are the most common power quality problem due to the increased use of a large numbers of sophisticated electronic equipment in industrial distribution system. The voltage disturbances such as voltage sags, swells, harmonics, unbalance and flickers. High quality in the power supply is needed, since failures due to such disturbances usually have a high impact on production cost. There are many different solutions to compensate voltage disturbances but the use of a DVR is considered to be the most cost effective method. The objective of this study is to propose a new topology of a DVR in order to mitigate voltage swells using a powerful power custom device namely the Dynamic Voltage Restorer (DVR. Approach: New configuration of a DVR with an improvement of a controller based on direct-quadrature-zero method has been introduced to compensate voltage swells in the network. Results: The effectiveness of the DVR with its controller were verify using Matlab/Simulinks SimPower Toolbox and then implemented using 5KVA DVR experimental setup. Simulations and experimental results demonstrate the effective dynamic performance of the proposed configuration. Conclusion: The implimentation of the proposed DVR validate the capabilities in mitigating of voltage swells effectiveness.During voltage swells, the DVR injects an appropriate voltage to maintain the load voltage at its nominal value.

  11. An evaluation of options to mitigate voltage rise due to increasing PV penetration in distribution networks

    Directory of Open Access Journals (Sweden)

    Carter Craig E.

    2017-01-01

    Full Text Available Australia and most other countries are adopting renewable energy generation as the dominant means of reducing dependence on fossil fuels. This has been made more feasible by the exponential take-up of solar photovoltaic (PV systems and their concurrent production scale-up and cost decline. Rooftop solar PV, combined with battery storage, seems likely to be the dominant means of providing household electricity needs. In response to the technical challenges from rooftop PV, network utilities have implemented various low cost options to cope with PV’s impact on network voltages. However, if we want this clean energy technology to fully utilise the available roof space and eventually meet residential electricity needs, additional hardware, control and commercial options will need to be adopted by both network utilities and their customers to overcome the technical barriers, especially voltage rise. This paper presents the authors’ evaluations of options to mitigate voltage rise, including operating solar inverters with reactive power absorption (var absorbing, dependent only on solar power output or operating the solar inverters in a volt–var response mode (voltage droop control where the inverter adjusts its reactive power (Q in response to changes in its terminal voltage – Q(V. This paper also considers the fulltime Q(V option, where an inverter’s reactive power capacity is independent of solar conditions – statcom mode. The network utility option of using line drop compensation (LDC – used on long rural MV feeders on urban MV feeders during daylight hours is assessed to lessen voltage rise on LV feeders with low net loading or reverse power flow due to high solar PV generation. The paper concludes that a combination of solar inverters performing fast fulltime voltage droop control outside a voltage deadband (statcom mode and HV/MV substation transformers with slow acting daytime LDC mitigates voltage rise, whilst limiting feeder

  12. Encephalitis due to antibodies to voltage gated potassium channel (VGKC with cerebellar involvement in a teenager

    Directory of Open Access Journals (Sweden)

    Megan M Langille

    2015-01-01

    Full Text Available Encephalitis due to antibodies to voltage gated potassium channel (VGKC typically presents with limbic encephalitis and medial temporal lobe involvement on neuroimaging. We describe a case of 13 year girl female with encephalitis due to antibodies to VGKC with signal changes in the cerebellar dentate nuclei bilaterally and clinical features that suggested predominant cerebellar involvement. These have never been reported previously in the literature. Our case expands the phenotypic spectrum of this rare condition.

  13. Encephalitis due to antibodies to voltage gated potassium channel (VGKC) with cerebellar involvement in a teenager.

    Science.gov (United States)

    Langille, Megan M; Desai, Jay

    2015-01-01

    Encephalitis due to antibodies to voltage gated potassium channel (VGKC) typically presents with limbic encephalitis and medial temporal lobe involvement on neuroimaging. We describe a case of 13 year girl female with encephalitis due to antibodies to VGKC with signal changes in the cerebellar dentate nuclei bilaterally and clinical features that suggested predominant cerebellar involvement. These have never been reported previously in the literature. Our case expands the phenotypic spectrum of this rare condition.

  14. Analysis of Mechanical Stresses Due to Voltage Dips in Fixed-Speed Wind Turbines

    DEFF Research Database (Denmark)

    Veluri, Badrinath; Santos-Martin, David; Jensen, Henrik Myhre

    2011-01-01

    drivetrain components. An electro-mechanical model is built to simulate the grid disturbances that easily excite the asynchronous generator poorly damped stator flux oscillations, which cause high transients of the generator electromagnetic torque. This article focuses in estimating the resulting significant...... stresses transients that may have a detrimental effect on the fatigue life of drivetrain system due to voltage dips. A rainflow cycle counting method for the stress history during the voltage dip event, analyses mean and amplitudes of the counted cycles, their occurrence moment and time of duration....

  15. A Quantities Method of Induction Motor Under Unbalanced Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Ayong Hiendro

    2010-08-01

    Full Text Available The most complete definition for the voltage unbalance is using complex voltage unbalance factor (CVUF that consists of its magnitude and angle. Unfortunately, the definition did not distinguish between undervoltage and overvoltage unbalance conditions. In this paper, the analysis of the motor is performed using the method of symmetrical component and MATLAB software is used to investigate the performance of induction motor. The simulation results show that the International Electrotechnical Commission (IEC definition of the voltage unbalance can be applied to evaluate total copper losses precisely. However, the phase angle of unbalance factor must be included for accurate predicting of peak currents and peak copper losses of the phase windings of the motor.The unbalanced conditions which distinguish between under and over voltage unbalance must also be taken into consideration for assessing all the quantities.

  16. Methodology for the assessment of possible damages in low voltage equipment due to lightning surges

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Nelson M.; Kagan, Nelson [University of Sao Paulo (USP), SP (Brazil)], Emails: matsuonm@usp.br, nelsonk@pea.usp.br; Domingues, Ivo T. [AES Eletropaulo, SP (Brazil); Jesus, Nelson C. de [AES Sul, Porto Alegre, RS (Brazil); Silva, Marcelo H.I. da [Grupo Rede, Sao Paulo, SP (Brazil); Takauti, Edson H. [Bandeirante, Sao Paulo, SP (Brazil)

    2007-07-01

    This paper deals with the development of a methodology to assess the possibility of equipment damages in low voltage customers due to lightning surges. The main objective is to incorporate this methodology in a computation system that supports distribution companies to determine the possible causes of equipment damages claimed by customers and to decide whether the claims are to be reimbursed or not. The proposed methodology determines whether a specific customer could be affected by a lightning strike according to his/her location and to the lightning main parameters, by using data from a lightning detection system and from the specific equipment surge withstand capability. A specific study using ATP (Alternative Transients Program) was carried out to assess the propagation of lightning surges in electric power distribution systems and their impact over low voltage customers. On the other hand, the withstand capability of the main household appliances was determined by a series of tests carried out in the University's power quality laboratory. The paper details the modeling used for simulation, such as network configuration, grounding points, and modelling of insulator flashover, distribution transformer, low voltage loads. It also presents some results regarding the evaluation of over voltages in low voltage customers installations. A practical method is proposed for assessing the possibility of equipment damage and describes how the existing uncertainties were handled. Also, some issues regarding the withstand capability of electric household appliances to lightning surges are discussed and some results of the laboratory tests are presented. (author)

  17. High-voltage electrical burns due to copper theft - Case series.

    Science.gov (United States)

    Braga, M J; Oliveira, I; Egipto, P; Silva, A

    2016-03-31

    Electrical burns are among the most devastating trauma inflicted on the human body. These burns have a higher morbidity, length of stay and a much higher risk of amputation than any other type of burn. Electrical burns affect mostly young, working males because they are more frequently the result of a work accident. However, possibly due to the worldwide economic crisis, we are experiencing a new phenomenon: the theft of high-voltage copper wiring.

  18. High-voltage electrical burns due to copper theft – Case series

    Science.gov (United States)

    Braga, M.J.; Oliveira, I.; Egipto, P.; Silva, A.

    2016-01-01

    Summary Electrical burns are among the most devastating trauma inflicted on the human body. These burns have a higher morbidity, length of stay and a much higher risk of amputation than any other type of burn. Electrical burns affect mostly young, working males because they are more frequently the result of a work accident. However, possibly due to the worldwide economic crisis, we are experiencing a new phenomenon: the theft of high-voltage copper wiring. PMID:27857650

  19. Effects of Unbalance Location on Dynamic Characteristics of High-speed Gasoline Engine Turbocharger with Floating Ring Bearings

    Institute of Scientific and Technical Information of China (English)

    WANG Longkai; BIN Guangfu; LI Xuejun; LIU Dingqu

    2016-01-01

    For the high-speed gasoline engine turbocharger rotor, due to the heterogeneity of multiple parts material, manufacturing and assembly errors, running wear in impeller and uneven carbon of turbine, the random unbalance usually can be developed which will induce excessive rotor vibration, and even lead to nonlinear vibration accidents. However, the investigation of unbalance location on the nonlinear high-speed turbocharger rotordynamic characteristics is less. In order to discuss the rotor unbalance location effects of turbocharger with nonlinear floating ring bearings(FRBs), the realistic turbocharger of gasoline engine is taken as a research object. The rotordynamic equations of motion under the condition of unbalance are derived by applied unbalance force and nonlinear oil film force of FRBs. The FE model of turbocharger rotor-bearing system is modeled which includes the unbalance excitation and nonlinear FRBs. Under the conditions of four different applied locations of unbalance, the nonlinear transient analyses are performed based on the rotor FEM. The differences of dynamic behavior are obvious to the turbocharger rotor systems for four conditions, and the bifurcation phenomena are different. From the results of waterfall and transient response analysis, the speed for the appearance of fractional frequency is not identical and the amplitude magnitude is different from the different unbalance locations, and the non-synchronous vibration does not occur in the turbocharger and the amplitude is relative stable and minimum under the condition 4. The turbocharger vibration and non-synchronous components could be reduced or suppressed by controlling the applied location of unbalance, which is helpful for the dynamic design, fault diagnosis and vibration control of the high-speed gasoline engine turbochargers.

  20. Gas Foil Bearing Misalignment and Unbalance Effects

    Science.gov (United States)

    Howard, Samuel A.

    2008-01-01

    The effects of misalignment and unbalance on gas foil bearings are presented. The future of U.S. space exploration includes plans to conduct science missions aboard space vehicles, return humans to the Moon, and place humans on Mars. All of these endeavors are of long duration, and require high amounts of electrical power for propulsion, life support, mission operations, etc. One potential source of electrical power of sufficient magnitude and duration is a nuclear-fission-based system. The system architecture would consist of a nuclear reactor heat source with the resulting thermal energy converted to electrical energy through a dynamic power conversion and heat rejection system. Various types of power conversion systems can be utilized, but the Closed Brayton Cycle (CBC) turboalternator is one of the leading candidates. In the CBC, an inert gas heated by the reactor drives a turboalternator, rejects excess heat to space through a heat exchanger, and returns to the reactor in a closed loop configuration. The use of the CBC for space power and propulsion is described in more detail in the literature (Mason, 2003). In the CBC system just described, the process fluid is a high pressure inert gas such as argon, krypton, or a helium-xenon mixture. Due to the closed loop nature of the system and the associated potential for damage to components in the system, contamination of the working fluid is intolerable. Since a potential source of contamination is the lubricant used in conventional turbomachinery bearings, Gas Foil Bearings (GFB) have high potential for the rotor support system. GFBs are compliant, hydrodynamic journal and thrust bearings that use a gas, such as the CBC working fluid, as their lubricant. Thus, GFBs eliminate the possibility of contamination due to lubricant leaks into the closed loop system. Gas foil bearings are currently used in many commercial applications, both terrestrial and aerospace. Aircraft Air Cycle Machines (ACMs) and ground

  1. Vestibular integrator neurons have quadratic functions due to voltage dependent conductances.

    Science.gov (United States)

    Magnani, Christophe; Eugène, Daniel; Idoux, Erwin; Moore, Lee E

    2013-12-01

    The nonlinear properties of the dendrites of the prepositus hypoglossi nucleus (PHN) neurons are essential for the operation of the vestibular neural integrator that converts a head velocity signal to one that controls eye position. A novel system of frequency probing, namely quadratic sinusoidal analysis (QSA), was used to decode the intrinsic nonlinear behavior of these neurons under voltage clamp conditions. Voltage clamp currents were measured at harmonic and interactive frequencies using specific nonoverlapping stimulation frequencies. Eigenanalysis of the QSA matrix reduces it to a remarkably compact processing unit, composed of just one or two dominant components (eigenvalues). The QSA matrix of rat PHN neurons provides signatures of the voltage dependent conductances for their particular dendritic and somatic distributions. An important part of the nonlinear response is due to the persistent sodium conductance (gNaP), which is likely to be essential for sustained effects needed for a neural integrator. It was found that responses in the range of 10 mV peak to peak could be well described by quadratic nonlinearities suggesting that effects of higher degree nonlinearities would add only marginal improvement. Therefore, the quadratic response is likely to sufficiently capture most of the nonlinear behavior of neuronal systems except for extremely large synaptic inputs. Thus, neurons have two distinct linear and quadratic functions, which shows that piecewise linear + quadratic analysis is much more complete than just piecewise linear analysis; in addition quadratic analysis can be done at a single holding potential. Furthermore, the nonlinear neuronal responses contain more frequencies over a wider frequency band than the input signal. As a consequence, they convert limited amplitude and bandwidth input signals to wider bandwidth and more complex output responses. Finally, simulations at subthreshold membrane potentials with realistic PHN neuron models

  2. Compound control method of neutral point voltage of three level NPC inverter based on the vector method of virtual space and hysteresis control

    Science.gov (United States)

    Yang, Fengping; Xiao, Fangfei

    2017-03-01

    Current control methods include hardware control and software control corresponding to the inherent unbalance problem of neutral point voltage in three level NPC inverter. The hardware control is rarely used due to its high cost. In this paper, a new compound control method has been presented based on the vector method of virtual space and traditional hysteresis control of neutral point voltage, which can make up the shortcoming of the virtual control without the feedback control system of neutral point voltage and the blind area of hysteresis control and control the deviation and wave of neutral point voltage. The accuracy of this method has been demonstrated by simulation.

  3. Background voltage distortion influence on power electric systems in the presence of the Steinmetz circuit

    Energy Technology Data Exchange (ETDEWEB)

    Sainz, Luis; Pedra, Joaquin [Department of Electrical Engineering, ETSEIB-UPC, Av. Diagonal 647, 08028 Barcelona (Spain); Caro, Manuel [IDOM Ingenieria y Arquitectura, C. Barcas 2, 46002 Valencia (Spain)

    2009-01-15

    In traction systems, it is usual to connect reactances in delta configuration with single-phase loads to reduce voltage unbalances and avoid electric system operation problems. This set is known as Steinmetz circuit. Parallel and series resonances can occur due to the capacitive reactance of the Steinmetz circuit and affect power quality. In this paper, the series resonance ''observed'' from the supply system is numerically located. The study of this resonance is important to avoid problems due to background voltage distortion. Experimental measurements are also presented to validate the obtained numerical results. (author)

  4. Statistics of subthreshold neuronal voltage fluctuations due to conductance-based synaptic shot noise.

    Science.gov (United States)

    Richardson, Magnus J E; Gerstner, Wulfram

    2006-06-01

    Neurons in the central nervous system, and in the cortex in particular, are subject to a barrage of pulses from their presynaptic populations. These synaptic pulses are mediated by conductance changes and therefore lead to increases or decreases of the neuronal membrane potential with amplitudes that are dependent on the voltage: synaptic noise is multiplicative. The statistics of the membrane potential are of experimental interest because the measurement of a single subthreshold voltage can be used to probe the activity occurring across the presynaptic population. Though the interpulse interval is not always significantly smaller than the characteristic decay time of the pulses, and so the fluctuations have the nature of shot noise, the majority of results available in the literature have been calculated in the diffusion limit, which is valid for high-rate pulses. Here the effects that multiplicative conductance noise and shot noise have on the voltage fluctuations are examined. It is shown that both these aspects of synaptic drive sculpt high-order features of the subthreshold voltage distribution, such as the skew. It is further shown that the diffusion approximation can only capture the effects arising from the multiplicative conductance noise, predicting a negative voltage skew for excitatory drive. Exact results for the full dynamics are derived from a master-equation approach, predicting positively skewed distributions with long tails in voltage ranges typical for action potential generation. It is argued that, although the skew is a high-order feature of subthreshold voltage distributions, the increased probability of reaching firing threshold suggests a potential role for shot noise in shaping the neuronal transfer function.

  5. Bunch motion in the presence of the self-induced voltage due to a reactive impedance with RF off

    Energy Technology Data Exchange (ETDEWEB)

    Shaposhnikova, E. [European Organization for Nuclear Research, Geneva (Switzerland)

    1996-08-01

    Analytic self-consistent solutions have been found for the nonlinear Vlasov equation describing different types of behaviour with time of an intense bunch under the influence of voltage induced due to a reactive part of broad band impedance. The problem is solved for the particular type of the initial distribution function in longitudinal phase space which is elliptic and corresponds to parabolic line density. This paper is devoted to the consideration of the effects in the machine with RF off. In this case the induced voltage is changing with time and can significantly affect bunch motion. The same method applied in the case with RF on allows the time dependent effects of potential well distortion to be analysed. Numerical estimations for the CERN SPS show that effect of induced voltage is important for beam manipulations with RF off. Measurements of the change in the rate of debunching with intensity can be used to estimate the value of the reactive impedance. (author)

  6. Analytical model of threshold voltage degradation due to localized charges in gate material engineered Schottky barrier cylindrical GAA MOSFETs

    Science.gov (United States)

    Kumar, Manoj; Haldar, Subhasis; Gupta, Mridula; Gupta, R. S.

    2016-10-01

    The threshold voltage degradation due to the hot carrier induced localized charges (LC) is a major reliability concern for nanoscale Schottky barrier (SB) cylindrical gate all around (GAA) metal-oxide-semiconductor field-effect transistors (MOSFETs). The degradation physics of gate material engineered (GME)-SB-GAA MOSFETs due to LC is still unexplored. An explicit threshold voltage degradation model for GME-SB-GAA-MOSFETs with the incorporation of localized charges (N it) is developed. To accurately model the threshold voltage the minimum channel carrier density has been taken into account. The model renders how +/- LC affects the device subthreshold performance. One-dimensional (1D) Poisson’s and 2D Laplace equations have been solved for two different regions (fresh and damaged) with two different gate metal work-functions. LCs are considered at the drain side with low gate metal work-function as N it is more vulnerable towards the drain. For the reduction of carrier mobility degradation, a lightly doped channel has been considered. The proposed model also includes the effect of barrier height lowering at the metal-semiconductor interface. The developed model results have been verified using numerical simulation data obtained by the ATLAS-3D device simulator and excellent agreement is observed between analytical and simulation results.

  7. Tertiary Control for Optimal Unbalance Compensation in Islanded Microgrids

    DEFF Research Database (Denmark)

    Meng, Lexuan; Tang, Fen; Savaghebi, Mehdi;

    2014-01-01

    In order to achieve desirable power quality in the critical bus (CB) in microgrids, primary and secondary control can be used to realize unbalance compensation and at the same time, to make distributed generators (DGs) share the compensation efforts. Considering that the power quality requirements...... in different areas and for different consumers can be different, this paper implements a tertiary control over secondary and primary control levels so as to achieve optimal unbalance compensation control. Hardware-in-the-loop results are presented to demonstrate the effectiveness of the method....

  8. Unbalance identification using the least angle regression technique

    Science.gov (United States)

    Chatzisavvas, Ioannis; Dohnal, Fadi

    2015-01-01

    The present investigation proposes a robust procedure for unbalance identification using the equivalent load method based on sparse vibration measurements. The procedure is demonstrated and benchmarked on an example rotor at constant speed. Since the number of measuring positions is much smaller than the number of possible fault locations, performing unbalance identification leads to an ill-posed problem. This problem was tried to be overcome previously with modal expansion in the time domain and with several linear regressions in the frequency domain. However, since the solution to the problem is a sparse equivalent force vector, these methods cannot provide a robust identification procedure. A robust identification can only be achieved by providing a-priori information on the number of unbalances to be identified. The presently proposed procedure achieves more precise unbalance identification without the need of a-priori information by incorporating a regularization technique. A well-known technique for producing sparse solutions is the Least Absolute Shrinkage and Selection Operator (LASSO). The proposed procedure is based on the generalized technique Least Angle Regression (LAR) which finds all the solutions of LASSO. A comparison of the time-domain approach, the frequency-domain approach and the proposed technique is made and the superiority of the latter technique in identifying the number of possible fault locations is highlighted. The selection of the threshold of the convergence algorithm of LAR as well as the selection of the value of the Lagrangian multiplier is discussed in some detail.

  9. Analysis of acoustic emission data for bearings subject to unbalance

    Directory of Open Access Journals (Sweden)

    Rapinder Sawhney

    2013-01-01

    Full Text Available Acoustic Emission (AE is an effective nondestructive method for investigating the behavior of materials under stress. In recent decades, AE applications in structural health monitoring have been extended to other areas such as rotating machineries and cutting tools. This research investigates the application of acoustic emission data for unbalance analysis and detection in rotary systems. The AE parameter of interest in this study is a discrete variable that covers the significance of count, duration and amplitude of AE signals. A statistical model based on Zero-Inflated Poisson (ZIP regression is proposed to handle over-dispersion and excess zeros of the counting data. The ZIP model indicates that faulty bearings can generate more transient wave in the AE waveform. Control charts can easily detect the faulty bearing using the parameters of the ZIP model. Categorical data analysis based on generalized linear models (GLM is also presented. The results demonstrate the significance of the couple unbalance.

  10. Redundant unbalance compensation of an active magnetic bearing system

    Science.gov (United States)

    Hutterer, Markus; Kalteis, Gerald; Schrödl, Manfred

    2017-09-01

    To achieve a good running behavior of a magnetic levitated rotor, a well-developed position controller and different compensation methods are required. Two very important structures in this context are the reduction of the gyroscopic effect and the unbalance vibration. Both structures have in common that they need the angular velocity information for calculation. For industrial applications this information is normally provided by an angle sensor which is fixed on the rotor. The angle information is also necessary for the field oriented control of the electrical drive. The main drawback of external position sensors are the case of a breakdown or an error of the motor controller. Therefore, the magnetic bearing can get unstable, because no angular velocity information is provided. To overcome this problem the presented paper describes the development of a selfsensing unbalance rejection in combination with a selfsensing speed control of the motor controller. Selfsensing means in this context that no angle sensor is required for the unbalance or torque control. With such structures two redundant speed and angle information sources are available and can be used for the magnetic bearing and the motor controller without the usage of an angle sensor.

  11. Stray voltage mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Jamali, B.; Piercy, R.; Dick, P. [Kinetrics Inc., Toronto, ON (Canada). Transmission and Distribution Technologies

    2008-04-09

    This report discussed issues related to farm stray voltage and evaluated mitigation strategies and costs for limiting voltage to farms. A 3-phase, 3-wire system with no neutral ground was used throughout North America before the 1930s. Transformers were connected phase to phase without any electrical connection between the primary and secondary sides of the transformers. Distribution voltage levels were then increased and multi-grounded neutral wires were added. The earth now forms a parallel return path for the neutral current that allows part of the neutral current to flow continuously through the earth. The arrangement is responsible for causing stray voltage. Stray voltage causes uneven milk production, increased incidences of mastitis, and can create a reluctance to drink water amongst cows when stray voltages are present. Off-farm sources of stray voltage include phase unbalances, undersized neutral wire, and high resistance splices on the neutral wire. Mitigation strategies for reducing stray voltage include phase balancing; conversion from single to 3-phase; increasing distribution voltage levels, and changing pole configurations. 22 refs., 5 tabs., 13 figs.

  12. Power conditioning using dynamic voltage restorers under different voltage sag types

    Directory of Open Access Journals (Sweden)

    Ahmed M. Saeed

    2016-01-01

    Full Text Available Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs. By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type.

  13. Power conditioning using dynamic voltage restorers under different voltage sag types.

    Science.gov (United States)

    Saeed, Ahmed M; Abdel Aleem, Shady H E; Ibrahim, Ahmed M; Balci, Murat E; El-Zahab, Essam E A

    2016-01-01

    Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs). By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type.

  14. CONDITION MONITORING AND FAULT DIAGNOSIS FOR TENSION UNBALANCE OF ROPES IN MULTI-ROPE FRICTION WINDER

    Institute of Scientific and Technical Information of China (English)

    杨兆建; 王勤贤; 任芳

    1997-01-01

    This paper analyzes the reasons of the tension unbalance of the ropes in multi-rope friction winder, introduces the method of an on-line monitoring rope tensions with a testing device developed by authors, and proposes the criteria of the fault diagnosis and the method of adjustment for the tension unbalance of the ropes, which is important to the theoretical study on the tension unbalance of the ropes and the maintenance of multi-rope winder.

  15. A Method for Compensating Customer Voltage Drops due to Nighttime Simultaneous Charging of EVs Utilizing Reactive Power Injection from Battery Chargers

    Science.gov (United States)

    Noda, Taku; Kabasawa, Yuichiro; Fukushima, Kentaro; Nemoto, Koshichi; Uemura, Satoshi

    When we consider the global warming, the reduction of CO2 emission is one of the most important problems which require urgent solutions. One option is to integrate low-CO2-emission generators to the grid as much as possible. Another option is to replace inefficient vehicles based on internal-combustion engines with electric ones (EVs). Due to the latter, we can easily estimate that most consumers will charge EVs' batteries at nighttime. Thus, excessive voltage drops due to the nighttime simultaneous charging are supposed to be a possible future problem. This paper proposes a method for compensating the voltage drops by injecting reactive power from EV battery chargers.

  16. ANN-based system for a discrimination between unbalanced supply voltage and phase loss in induction motors

    OpenAIRE

    Refaat, Shady S.; Abu-Rub, Haitham; Iqbal, Atif

    2014-01-01

    It is documented that almost 98% of all voltage generated by electric utilities has up to 3% unbalance. Single phasing fault deserves special attention since phase loss is considered the worst case of unbalanced supply voltage. This paper focuses on unbalanced supply condition diagnosis and discrimination between an unbalance in the supply and phase loss fault. The discrimination will be based on the ratio of third harmonic to fundamental Fast Fourier Transform (FFT) magnitude components (RTH...

  17. Investigations of surface characterization of silicone rubber due to tracking phenomena under a.c. and d.c. voltages

    Indian Academy of Sciences (India)

    Uma Maheswar Rao; S S M S Abdul Majeed; C Venkataseshaiah; R Sarathi

    2002-11-01

    In the present work, tracking phenomena has been studied with silicone rubber material under the a.c. and d.c. voltages following IEC-587 standards. The surface condition of the tracked zone was analysed using wide angle X-ray diffraction (WAXD) and thermogravimetric differential thermal analysis (TG–DTA) studies. The tracking time was different for a.c. and d.c. voltages.

  18. Threshold-Voltage Shifts in Organic Transistors Due to Self-Assembled Monolayers at the Dielectric: Evidence for Electronic Coupling and Dipolar Effects.

    Science.gov (United States)

    Aghamohammadi, Mahdieh; Rödel, Reinhold; Zschieschang, Ute; Ocal, Carmen; Boschker, Hans; Weitz, R Thomas; Barrena, Esther; Klauk, Hagen

    2015-10-21

    The mechanisms behind the threshold-voltage shift in organic transistors due to functionalizing of the gate dielectric with self-assembled monolayers (SAMs) are still under debate. We address the mechanisms by which SAMs determine the threshold voltage, by analyzing whether the threshold voltage depends on the gate-dielectric capacitance. We have investigated transistors based on five oxide thicknesses and two SAMs with rather diverse chemical properties, using the benchmark organic semiconductor dinaphtho[2,3-b:2',3'-f]thieno[3,2-b]thiophene. Unlike several previous studies, we have found that the dependence of the threshold voltage on the gate-dielectric capacitance is completely different for the two SAMs. In transistors with an alkyl SAM, the threshold voltage does not depend on the gate-dielectric capacitance and is determined mainly by the dipolar character of the SAM, whereas in transistors with a fluoroalkyl SAM the threshold voltages exhibit a linear dependence on the inverse of the gate-dielectric capacitance. Kelvin probe force microscopy measurements indicate this behavior is attributed to an electronic coupling between the fluoroalkyl SAM and the organic semiconductor.

  19. Unbalance vibration suppression for AMBs system using adaptive notch filter

    Science.gov (United States)

    Chen, Qi; Liu, Gang; Han, Bangcheng

    2017-09-01

    The unbalance of rotor levitated by active magnetic bearings (AMBs) will cause synchronous vibration which greatly degrade the performance at high speeds in the rotating machinery. To suppress the unbalance vibration without angular velocity information, a novel modified adaptive notch filter (ANF) with phase shift in the AMBs system is presented in this study. Firstly, a 4-degree-of-freedom (DOF) radial unbalanced AMB rotor system is described and analyzed, and the solution of rotor vibration displacement is compared with the experimental data to verify the preciseness of the dynamic model. Then the principle and structure of the proposed notch filter used for the frequency estimation and online identification of synchronous component are presented. As well, the convergence property of the algorithm is investigated. In addition, the stability analysis of the closed-loop AMB system with the proposed ANF is conducted. Simulation and experiments on an AMB driveline system demonstrate the effectiveness and the adaptive characteristics of the proposed ANF on the elimination of synchronous controlled current in a widely operating speed range.

  20. Uncertainty in real-time voltage stability assessment methods based on Thevenin equivalent due to PMU’s accuracy

    DEFF Research Database (Denmark)

    Perez, Angel; Møller, Jakob Glarbo; Jóhannsson, Hjörtur;

    2014-01-01

    This article studies the influence of PMU’s accuracy in voltage stability assessment, considering the specific case of Th ́ evenin equivalent based methods that include wide-area information in its calculations. The objective was achieved by producing a set of synthesized PMU measurements from...

  1. Kinetics deformation of current-voltage characteristics of the varistor oxide structures due to overcharging of the localized states

    Directory of Open Access Journals (Sweden)

    Tonkoshkur A. S.

    2014-12-01

    Full Text Available Prolonged exposure of zinc oxide varistors to the electrical load leads to current-voltage characteristics (CVC deformation, which is associated with a change in the height and width of the intergranular barriers, which are main structural element of the varistors. Polarization phenomena in zinc oxide ceramics are studied in a number of works, but those are mainly limited to the study of the physics of the CVC deformation process and to determining the parameters of localized electronic states involved in this process. This paper presents the results on the simulation of the deformation of pulse CVC of a separate intergranular potential barrier at transient polarization/depolarization, associated with recharging of surface electronic states (SES, which cause this barrier. It is found that at high density of SES their degree of electron filling is small and the effect of DC voltage leads to a shift of pulse current-voltage characteristics into the region of small currents. Conversely, the low density SES are almost completely filled with electrons, and after crystallite polarization CVC is shifted to high currents. Experimental studies have confirmed the possibility of applying the discovered laws to ceramic varistor structures. The proposed model allows interpreting the «anomalous» effects (such as increase in the classification voltage and reduction of active losses power observed during the varistors accelerated aging test.

  2. Urban exposure to ELF magnetic field due to high-, medium- and low-voltage electricity supply networks.

    Science.gov (United States)

    Bottura, V; Cappio Borlino, M; Carta, N; Cerise, L; Imperial, E

    2009-12-01

    The regional environment protection agency (ARPA) of the Aosta Valley region in north Italy performed a survey of magnetic field triggered by the power supply network in high, medium and low voltages on the entire area of Aosta town. The electrical distribution system for houses was not however taken into account. The aim of the survey was to evaluate the global population exposure and not simply the assessment of the legal exposure limit compliance.

  3. Identification of Rub and Unbalance in 320-MW Turbogenerators

    Directory of Open Access Journals (Sweden)

    N. Bachschmid

    2004-01-01

    Full Text Available This article presents two experiences of application of a model-based fault identification method on real machines. The first case presented is an unbalance identification on a 320-MW turbogenerator unit operating in a fossil power plant. In the second case, concerning a machine of the same size but of a different manufacturer, the Low Pressure (LP turbine was affected by a rub in the sealings and this time, the fault was modeled by local bows. The identification of the faults is performed by means of a model-based identification technique in frequency domain, suitably modified in order to take into account simultaneous faults. The theoretical background of the applied method is briefly illustrated and some considerations also are presented about the best choice of the rotating speed set of the run-down transient to be used for an effective identification and about the appropriate weighting of vibration measurements at the machine bearings.

  4. Identification of Rub and Unbalance in 320 MW Turbogenerators

    Directory of Open Access Journals (Sweden)

    N. Bachschmid

    2003-01-01

    Full Text Available This article presents two experiences of applying a model-based fault-identification method to real machines. The first case presented is an unbalance identification in a 320 MW turbogenerator unit operating in a fossil power plant. In the second case, concerning a machine of the same size but from a different manufacturer, the turbine has been affected by a rub in the sealings. This time, the fault is modeled by local bows. The identification of the faults is performed by means of a model-based identification technique in a frequency domain, suitably modified in order to take into account simultaneous faults. The theoretical background of the applied method is briefly illustrated and some considerations are also presented about the best choice of the rotating speed set of the run-down transient to be used for an effective identification and about the appropriate weighting of vibration measurements at the machine bearings.

  5. Therapeutic plasma exchange as a steroid-sparing therapy in a patient with limbic encephalitis due to antibodies to voltage-gated potassium channels.

    Science.gov (United States)

    Martin, Isabella W; Martin, Christi-Lynn B; Dunbar, Nancy M; Lee, Stephen L; Szczepiorkowski, Zbigniew M

    2016-02-01

    Autoantibodies to the voltage-gated potassium channel (VGKC) complex cause a spectrum of non-paraneoplastic neurologic syndromes including limbic encephalitis (LE). We report a case of a man with LE who underwent a course of therapeutic plasma exchange (TPE) in addition to other immunomodulatory therapies and experienced sustained clinical resolution of his symptoms. This report adds to the existing literature supporting TPE in cases of LE due to VGKC complex autoantibodies.

  6. Elevated neuronal excitability due to modulation of the voltage-gated sodium channel Nav1.6 by Aβ1-42

    Directory of Open Access Journals (Sweden)

    Xi eWang

    2016-03-01

    Full Text Available Aberrant increases in neuronal network excitability may contribute to the cognitive deficits in Alzheimer’s disease (AD. However, the mechanisms underlying hyperexcitability are not fully understood. Such overexcitation of neuronal networks has been detected in the brains of APP/PS1 mice. In the present study, using current-clamp recording techniques, we observed that 12 days in vitro (DIV primary cultured pyramidal neurons from P0 APP/PS1 mice exhibited a more prominent action potential burst and a lower threshold than WT littermates. Moreover, after treatment with Aβ1-42 peptide, 12 DIV primary cultured neurons showed similar changes, to a greater degree than in controls. Voltage-clamp recordings revealed that the voltage-dependent sodium current density of neurons incubated with Aβ1-42 was significantly increased, without change in the voltage-dependent sodium channel kinetic characteristics. Immunohistochemistry and western blot results showed that, after treatment with Aβ1-42, expressions of Nav and Nav1.6 subtype increased in cultured neurons or APP/PS1 brains compared to control groups. The intrinsic neuronal hyperexcitability of APP/PS1 mice might thus be due to an increased expression of voltage-dependent sodium channels induced by Aβ1-42. These results may illuminate the mechanism of aberrant neuronal networks in AD.

  7. Multi-objective optimization control of plug-in electric vehicles in low voltage distribution networks

    DEFF Research Database (Denmark)

    García-Villalobos, J.; Zamora, I.; Knezovic, Katarina

    2016-01-01

    The massive introduction of plug-in electric vehicles (PEVs) into low voltage (LV) distribution networks will lead to several problems, such as: increase of energy losses, decrease of distribution transformer lifetime, lines and transformer overload issues, voltage drops and unbalances...

  8. Unbalance Identification of Speed-Variant Rotary Machinery without Phase Angle Measurement

    Directory of Open Access Journals (Sweden)

    Cong Yue

    2015-01-01

    Full Text Available As rotary mechanical structure becomes more complicated, difficulty arises in receiving prime correction mass and optimum balancing plane efficiently. An innovative modal balancing process for estimating the residual unbalance from different equilibrium plane of complex flexible rotor system is presented. The method is based on a numerical approach with modal ratio among measurement points (MRMP coefficient and triple phase method (TPM. The veracity of calculation result is verified by an academic rotor model. The latter study in this paper is subsequently put forward through a power turbine rotor modeled by finite element method. Simulation results show that proper equilibrium plane performs commendably in recognizing residual unbalance and reducing the vibration effect through the critical region. Moreover, the inherent unbalance recognized by experimental data from a turbine rotor with slender shaft is found to be in certain difference under different counterweight combination. Choosing suitable balancing planes will improve the accuracy of unbalance identification.

  9. An Enhanced Power Sharing Scheme for Voltage unbalance and harmonics compensation in an islanded AC microgrid

    DEFF Research Database (Denmark)

    Han, Yang; Shen, Pan; Zhao, Xin

    2016-01-01

    ) technique is adopted to send the compensation command of the secondary control and auxiliary control from the microgrid control center (MGCC) to the local controllers of DG unit. Finally, the hardware-in-the-loop (HIL) results using dSPACE 1006 platform are presented to demonstrate the effectiveness...

  10. Model-Based Degree Estimation of Unbalance and Misalignment in Flexible Coupling-rotor System

    Institute of Scientific and Technical Information of China (English)

    LI Changyou; XU Minqiang; GUO Song; WANG Yuewu; WANG Rixin

    2009-01-01

    The condition of rotor system must be assessed in order to develop condition-based maintenance for rotating machinery. It is determined by multiple variables such as unbalance degree, misalignment degree, the amount of bending deformation of the shaft, occurrence of shaft crack of rotor system and so on. The estimation of the degrees of unbalance and misalignment in flexible coupling-rotor system is discussed. The model-based approach is employed to solve this problem. The models of the equivalent external loads for unbalance and misalignment are derived and analyzed. Then, the degrees of unbalance and misalignment are estimated by analyzing the components of the equivalent external loads of which the frequencies are equal to the 1 and 2 times running frequency respectively. The equivalent external loads are calculated according to the dynamic equation of the original rotor system and the differences between the dynamical responses in normal case and the vibrations when the degree of unbalance or misalignment or both changes. The denoise method based on bandpass filter is used to decrease the effect of noise on the estimation accuracy. The numerical examples are given to show that the proposed approach can estimate the degrees of unbalance and misalignment of the flexible coupling-rotor system accurately.

  11. Assessment of the risk of failure of high voltage substations due to environmental conditions and pollution on insulators.

    Science.gov (United States)

    Castillo Sierra, Rafael; Oviedo-Trespalacios, Oscar; Candelo, John E; Soto, Jose D

    2015-07-01

    Pollution on electrical insulators is one of the greatest causes of failure of substations subjected to high levels of salinity and environmental pollution. Considering leakage current as the main indicator of pollution on insulators, this paper focuses on establishing the effect of the environmental conditions on the risk of failure due to pollution on insulators and determining the significant change in the magnitude of the pollution on the insulators during dry and humid periods. Hierarchical segmentation analysis was used to establish the effect of environmental conditions on the risk of failure due to pollution on insulators. The Kruskal-Wallis test was utilized to determine the significant changes in the magnitude of the pollution due to climate periods. An important result was the discovery that leakage current was more common on insulators during dry periods than humid ones. There was also a higher risk of failure due to pollution during dry periods. During the humid period, various temperatures and wind directions produced a small change in the risk of failure. As a technical result, operators of electrical substations can now identify the cause of an increase in risk of failure due to pollution in the area. The research provides a contribution towards the behaviour of the leakage current under conditions similar to those of the Colombian Caribbean coast and how they affect the risk of failure of the substation due to pollution.

  12. Understanding the unbalanced-voltage problem in wind turbine generation

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Butterfield, C.P.; Batan, T.; Yildirim, D.

    2000-02-28

    Most wind turbines are equipped with line-connected induction generators. Induction generators are very attractive as wind turbine generators due to their low cost, ruggedness and the need for little or no maintenance. At constant frequency, the induction generator operates in a small range of speeds and, therefore, it operated with a small range of slips with respect to synchronous speed. Compared to a synchronous generator, an induction generator provides lower stiffness, thus alleviating the mechanical stress. In a weak power system network, an unbalanced load at the distribution lines can cause unbalanced voltage conditions. If an induction generator is connected to an unbalanced voltage, the resulting stator current will be unbalanced. The unbalanced current creates unequal heating (hot spots) on the stator winding. The heat may increase the winding temperature, which degrades the insulation of the winding, i.e., the life expectancy of the winding. Unbalanced currents also create torque pulsation on the shaft resulting in audible noise and extra mechanical stress. This paper explores the unbalanced voltage problem in induction generators. The levels of unbalance and the loads are varied. Experimental and predicted results are presented in this paper.

  13. A Novel Neutral Point Voltage Control Strategy for Three-Level NPC APF Based on SVPWM

    Directory of Open Access Journals (Sweden)

    Yao Xiaolong

    2015-01-01

    Full Text Available The unbalance of the neutral point voltage is an inherent problem of three-level neutral-point-clamped (NPC Active Power Filter (APF; this paper analyzes the causes of unbalanced neutral point voltage and studies the reason of the unbalance of the neutral point voltage. A novel neutral point voltage control strategy using Space Vector Pulse Width Modulation (SVPWM is proposed. The proposed strategy is based on the traditional SVPWM, by controlling the effect time of small vector, which can change the state of the midpoint voltage fluctuation, and the neutral point voltage can be maintained balance. The influence of the vector on neutral point balance is investigated in depth. Simulation results show the neutral point voltage balancing control strategy based on SPWM is effective.

  14. Secondary Control for Voltage Quality Enhancement in Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2012-01-01

    In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each...... of these controllers includes a selective virtual impedance loop which is considered to improve sharing of fundamental and harmonic components of load current among the DG units. The sharing improvement is provided at the expense of increasing voltage unbalance and harmonic distortion. Thus, the secondary control...... level is applied to manage the compensation of SLB voltage unbalance and harmonics by sending proper control signals to the primary level. DGs compensation efforts are controlled locally at the primary level. The system design procedure for selecting proper control parameters is discussed. Simulation...

  15. Phase-lock loop of Grid-connected Voltage Source Converter under non-ideal grid condition

    DEFF Research Database (Denmark)

    Wang, Haojie; Sun, Hai; Han, Minxiao

    2015-01-01

    phase information cannot be accurately tracked. Based on analysis of the cause of double-frequency ripple when unbalance exists in main grid, a phase-locked loop (PLL) detection technique is proposed. Under the conditions of unsymmetrical system voltage, varying system frequency, single-phase system...... and distorted system voltage the proposed PLL can accurately detect the fundamental positive-sequence component of grid voltage thus accurate control of DC micro-grid voltage can be realized....

  16. Consideration of Gyroscopic Effect in Fault Detection and Isolation for Unbalance Excited Rotor Systems

    Directory of Open Access Journals (Sweden)

    Zhentao Wang

    2012-01-01

    Full Text Available Fault detection and isolation (FDI in rotor systems often faces the problem that the system dynamics is dependent on the rotor rotary frequency because of the gyroscopic effect. In unbalance excited rotor systems, the continuously distributed unbalances are hard to be determined or estimated accurately. The unbalance forces as disturbances make fault detection more complicated. The aim of this paper is to develop linear time invariant (LTI FDI methods (i.e., with constant parameters for rotor systems under consideration of gyroscopic effect and disturbances. Two approaches to describe the gyroscopic effect, that is, as unknown inputs and as model uncertainties, are investigated. Based on these two approaches, FDI methods are developed and the results are compared regarding the resulting FDI performances. Results are obtained by the application in a rotor test rig. Restrictions for the application of these methods are discussed.

  17. Active magnetic bearings dynamic parameters identification from experimental rotor unbalance response

    Science.gov (United States)

    Xu, Yuanping; Zhou, Jin; Di, Long; Zhao, Chen

    2017-01-01

    Active magnetic bearings (AMBs) support rotors using electromagnetic force rather than mechanical forces. It is necessary to accurately identify the AMBs force coefficients since they play a critical role in the rotordynamic analysis including system stability, bending critical speeds and modes of vibrations. This paper proposes a rotor unbalance response based approach to identifying the AMBs stiffness and damping coefficients during rotation. First, a Timoshenko beam finite element (FE) rotor model is created. Second, an identification procedure based on the FE model is proposed. Then based on the experimental rotor unbalance response data from 1200 rpm to 30,000 rpm, the AMBs dynamic force parameters (stiffness and damping) are obtained. Finally, the identified results are verified by comparing the estimated and experimental rotor unbalance responses, which shows high accuracy.

  18. DRIFT MOTION OF FREE-ROTOR GYROSCOPE WITH RADIAL MASS-UNBALANCE

    Institute of Scientific and Technical Information of China (English)

    刘延柱; 薛纭

    2004-01-01

    The motion of a rigid body about fixed point with small radial mass-unbalance in homogeneous gravitational field was discussed. The dynamical equations described by state variables of the body were established, and approximate analytical solutions for a spinning body with high speed were obtained by use of the average method. The influence of the radial mass-unbalance of the rotor to the precession character of a free-rotor gyroscope was analyzed. And a physical explanation of the drift phenomenon of the gyro was given. An applicable formula of gyro' s constant drift in analytical form was obtained, which is perfectly coincident with the numerical calculation.

  19. Impedance Based Analysis of DFIG Stator Current Unbalance and Distortion Suppression Strategies

    DEFF Research Database (Denmark)

    Song, Yipeng; Zhou, Dao; Blaabjerg, Frede

    2016-01-01

    (VPI) regulator. Nevertheless, these two resonance regulators have never been compared from the perspective of suppression capability of output current unbalance and distortion. In this paper, the impedance based analysis method is adopted to theoretically explain and compare the DFIG system impedance...... reshaping though the introduction of R and VPI regulator. It is pointed out that, when implemented in the DFIG system output current unbalance and distortion suppression, the VPI regulator (equivalent to the combination of virtual positive inductor and virtual positive resistor) has two advantages over R...

  20. Technical feasibility study of Voltage Optimization Unit

    DEFF Research Database (Denmark)

    Hu, Junjie; Marinelli, Mattia; Coppo, Massimiliano

    transformer with OLTC per phase is necessary and valuable. The main conclusion is that power distribution transformer with OLTC control on each phase can significantly improve the PV hosting capacity in the analyzed unbal-anced scenarios. To investigate the verification problem, a simulation study...... is performed using the soft-wares DigSilent PowerFactory and Matlab. In this simulation study, a real low voltage network from Dong Eldistribution is modeled in Powerfactory. The measured data of the real low voltage network is analyzed and the resulting loading profiles including active and reactive power...... are used as load basics for the analysis. In term of PV genera-tion profiles, a realistic PV output power is assumed. Four relevant indicies such as phase neutral voltage, netural potential voltage, unbalanced factor (VUF), and power losses are evaluated in the present study. The simulation tests include...

  1. Influence of unbalance levels on nonlinear dynamics of a rotor-backup rolling bearing system

    Science.gov (United States)

    Fonseca, Cesar A.; Santos, Ilmar F.; Weber, Hans I.

    2017-04-01

    Rotor drops in magnetic bearing and unbalance in rotors have been objective of study for many years. The combination of these two well-known phenomena led to an interesting chaotic response, when the rotor touches the inner race of the back-up bearing. The present work explores the nonlinear rotor backup bearing dynamics both theoretically and experimentally using a fully instrumented test rig, where the position of shaft, its angular velocity and the contact forces between the shaft and the backup bearing are sampled at 25 kHz. The test rig is built by a removable passive magnetic bearing, which allows for simulation of magnetic bearing failure (loss of carrying capacity and rotor fall). The rotor is studied numerically as well as experimentally. A theoretical approach is given beforehand and supplies the basis of the study. Finally the presented results are commented on the point of view of nonlinear dynamics applied to the practical use. The theoretical and numerical analyses are shown through orbit plots, phase plans, Poincaré maps, force response in time and double sided spectrum. The latter is important to characterize the condition at different levels of unbalance between forward and backward whirl. Our preliminary results indicate that for smaller amount of unbalance the rotor swings at the bottom of the bearing, the more the unbalance increases, other dynamical behavior occur and some can be extremely harmful, since the rotor can be lifted from the contact state and return, starting to impact innumerable times without reaching a steady state.

  2. Influence of unbalance levels on nonlinear dynamics of a rotor-backup rolling bearing system

    DEFF Research Database (Denmark)

    Fonseca, Cesar A.; Santos, Ilmar; Weber, Hans I.

    2017-01-01

    Rotor drops in magnetic bearing and unbalance in rotors have been objective of study for many years. The combination of these two well-known phenomena led to an interesting chaotic response, when the rotor touches the inner race of the back-up bearing. The present work explores the nonlinear roto...

  3. Voltage Control for Unbalanced Low Voltage Grids Using a Decoupled-Phase On-Load Tap-Changer Transformer and Photovoltaic Inverters

    OpenAIRE

    Zecchino, Antonio; Marinelli, Mattia; Hu, Junjie; Coppo, Massimiliano; Turri, Roberto

    2015-01-01

    This paper presents modeling and analysis of the potential benefits of joint actions of a MV/LV three-phase power distribution transformer with independent on-load tap-changer control on each phase and photovoltaic inverters provided with reactive power control capability, in terms of accommodating more renewable generations in the LV grid. The potential benefits are investigated in terms of voltage unbalance reduction and local voltage regulation. 24-hours root-mean-square dynamics simulatio...

  4. 我国探险旅游发展中的供需失衡分析及对策%Study on Supply and Demand Unbalance and Countermeasures of Adventure Tourism in China

    Institute of Scientific and Technical Information of China (English)

    李如友

    2011-01-01

    探险旅游因其危险性、专业性和刺激性等特点对旅游活动的风险防范、安全保障和技术支持提出了较高要求。我国探险旅游在这些方面均存有不足,供需失衡为主要诱因。我国探险旅游的供需失衡表现为市场需求与有效供给的失衡、产品构成与旅游期望的失衡、组织方式与安全需要的失衡。应通过规范市场供给、加强探险旅游产品开发、完善安全保障体系、引导探险旅游需求、帮助旅游者正确认识自身需求等措施,可使供需失衡问题得到消除或缓解。%Due to its features such as risk, specialization and excitation, adventure tourism has raised much higher requirements in the aspect of risk prevention, security and technique support. But the adventure tourism in China has many defects which are mainly triggered by the supply and demand unbalance in this field. This unbalance consists three parts: the unbalance between market demand and solid supply, the unbalance between product structure and tourism expectation, the unbalance between organization mode and security requirement. The problem can be eliminated or ameliorated by standardization of the market supply, strengthening the development of adventure product, establishment of security system, guidance of the demand, helping the traveler to recognize their demand.

  5. Voltage sags due to the short-circuits on transmission lines; Afundamentos de tensao provocados por curto-circuitos em linhas de transmissao

    Energy Technology Data Exchange (ETDEWEB)

    Klock Junior, Odemar Solano [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil)

    2001-07-01

    This paper analyses the voltage sags influence on the buses, including the ones where consumers of the COPEL transmission electric system, determining the sags number and the approximate values for short-circuits on transmission lines. The voltage values, during the the short-circuit regime are obtained from the data for the short-circuit program. The short-circuits are simulated by the assembly of the electric system impedance matrix, from where the voltage values for short-circuits on any point of the electric system can be determined using simply calculations.

  6. Impedance Based Analysis of DFIG Stator Current Unbalance and Distortion Suppression Strategies

    DEFF Research Database (Denmark)

    Song, Yipeng; Zhou, Dao; Blaabjerg, Frede

    2016-01-01

    The control strategies of Doubly Fed Induction Generator (DFIG) system output current unbalance and distortion suppression have been well investigated in detail, with the implementation of two kinds of resonant regulators, i.e., conventional Resonance (R) regulator or Vector Proportional Integral...... regulator (equivalent to the combination of virtual positive resistor and virtual negative inductor), i.e., better high order harmonic distortion suppression. The theoretical analysis and MATLAB simulation results have validated the correctness of this conclusion....... reshaping though the introduction of R and VPI regulator. It is pointed out that, when implemented in the DFIG system output current unbalance and distortion suppression, the VPI regulator (equivalent to the combination of virtual positive inductor and virtual positive resistor) has two advantages over R...

  7. Impedance Based Analysis of DFIG Stator Current Unbalance and Distortion Suppression Strategies

    DEFF Research Database (Denmark)

    Song, Yipeng; Zhou, Dao; Blaabjerg, Frede

    2016-01-01

    reshaping though the introduction of R and VPI regulator. It is pointed out that, when implemented in the DFIG system output current unbalance and distortion suppression, the VPI regulator (equivalent to the combination of virtual positive inductor and virtual positive resistor) has two advantages over R...... regulator (equivalent to the combination of virtual positive resistor and virtual negative inductor), i.e., better high order harmonic distortion suppression. The theoretical analysis and MATLAB simulation results have validated the correctness of this conclusion....

  8. Correlation between arterial blood gas analysis and peripheral blood gas analysis in acid-base unbalance state

    OpenAIRE

    Hyun Lee Kim; Hyun Ho Ryu

    2012-01-01

    Acid-base unbalance is most common problem in severe ill patient, especially in condition of abnormal renal function state. Acid-base unbalances are respiratory acidosis, respiratory alkalosis, metabolic acidosis, and metabolic alkalosis. Metabolic acidosis is frequently appeared in clinical state. Arterial blood gas analysis is considered as a basic test to the intensive care unit patient and emergency state. Recently some researches were done, comparing with arterial blood gas analysis and ...

  9. Semigroup based neural network architecture for extrapolation of mass unbalance for rotating machines in power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.H.; Velas, J.P.; Lee, K.Y [Pennsylvania State Univ., University Park, PA (United States). Dept. of Electrical Engineering

    2006-07-01

    This paper presented a mathematical method that power plant operators can use to estimate rotational mass unbalance, which is the most common source of vibration in turbine generators. An unbalanced rotor or driveshaft causes vibration and stress in the rotating part and in its supporting structure. As such, balancing the rotating part is important to minimize structural stress, minimize operator annoyance and fatigue, increase bearing life, or minimize power loss. The newly proposed method for estimating vibration on a turbine generator uses mass unbalance extrapolation based on a modified system-type neural network architecture, notably the semigroup theory used to study differential equations, partial differential equations and their combinations. Rather than relying on inaccurate vibration measurements, this method extrapolates a set of reliable mass unbalance readings from a common source of vibration. Given a set of empirical data with no analytic expression, the authors first developed an analytic description and then extended that model along a single axis. The algebraic decomposition which was used to obtain the analytic description of empirical data in the semigroup form involved the product of a coefficient vector and a basis set of vectors. The proposed approach was simulated on empirical data. The concept can also be tested in many other engineering and non-engineering problems. 23 refs., 11 figs.

  10. Induced Unbalance as a Method for Improving the Dynamic Stability of High-Speed Turbochargers

    KAUST Repository

    Gordon Kirk, R.

    2011-01-01

    The high-speed diesel engine turbocharger is known to have subsynchronous vibrations for a wide speed range. The bearing fluid-film instability is the main source of the vibration. The nonlinear forces inside the bearings are causing the rotor to whirl in a limit cycle. This study presents a new method for improving the dynamic stability by inducing the turbocharger rotor unbalance in order to suppress the subsynchronous vibration. The finite-element model of the turbocharger with floating-ring bearings is numerically solved for the nonlinear time-transient response. Both compressor and turbine added unbalance are induced and the dynamic stability is computed. The turbocharger model with linearized floating-ring bearings is also solved for eigenvalues to predict the modes of instability. The linear analysis demonstrates that the forward whirling mode of the floating-ring at the compressor end also becomes unstable at the higher turbocharger speeds, in addition to the unstable forward conical and cylindrical modes. The numerical predictions are also compared to the former experimental results of a similar turbocharger. The results of the study show that the subsynchronous frequency amplitude of the dominant first mode is reduced when inducing either the compressor or the turbine unbalance at a certain level. © 2011 R. Gordon Kirk and Ali A. Alsaeed.

  11. Investigation of surface modifications in ethylene propylene diene monomer (EPDM) rubber due to tracking under a.c. and d.c. voltages

    Indian Academy of Sciences (India)

    R Sarathi; Uma Maheswar Rao

    2001-12-01

    In the present work, tracking phenomena has been studied with the ethylene propylene diene monomer (EPDM) material under the a.c. and d.c. voltages, with ammonium chloride/acid rain solution as the contaminant. It is noticed that the tracking time depends on the conductivity and flow rate of the contaminant. The physico-chemical analyses viz. wide angle X-ray diffraction (WAXD), thermo-gravimetric differential thermal analysis (TG-DTA) and the differential scanning calorimetry (DSC) studies, were carried out and it was concluded that the tracking process is a surface degradation process. The tracking time is different for a.c. and d.c. voltages.

  12. A Review of Voltage and Current Signature Diagnosis in Industrial Drives

    Directory of Open Access Journals (Sweden)

    K. Vinoth Kumar

    2011-09-01

    Full Text Available This paper presents the review of identify the different types of faults in the induction motor during online condition by using current and voltage signature analysis. Special attention is focused on the effect of both space distribution of rotor breakage and rotor dis-symmetry on the mechanism of generation of diagnosis signatures with the consideration of voltage supply unbalance and speed ripples. A comparison is made between the voltage signature analysis and current signature analysis. Keywords: Fault diagnosis, Induction motor, rotor breakage, MCSA, Motor voltage signature analysis (MVSA.

  13. DC-link voltage balancing in cascaded H-Bridge converters

    Directory of Open Access Journals (Sweden)

    Lewicki Arkadiusz

    2014-09-01

    Full Text Available In this paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM. It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches on proposed control strategy are presented in the paper

  14. New Control Technique Applied in Dynamic Voltage Restorer for Voltage Sag Mitigation

    Directory of Open Access Journals (Sweden)

    Rosli Omar

    2010-01-01

    Full Text Available The Dynamic Voltage Restorer (DVR was a power electronics device that was able to compensate voltage sags on critical loads dynamically. The DVR consists of VSC, injection transformers, passive filters and energy storage (lead acid battery. By injecting an appropriate voltage, the DVR restores a voltage waveform and ensures constant load voltage. There were so many types of the control techniques being used in DVR for mitigating voltage sags. The efficiency of the DVR depends on the efficiency of the control technique involved in switching the inverter. Problem statement: Simulation and experimental investigation toward new algorithms development based on SVPWM. Understanding the nature of DVR and performance comparisons between the various controller technologies available. The proposed controller using space vector modulation techniques obtain higher amplitude modulation indexes if compared with conventional SPWM techniques. Moreover, space vector modulation techniques can be easily implemented using digital processors. Space vector PWM can produce about 15% higher output voltage than standard Sinusoidal PWM. Approach: The purpose of this research was to study the implementation of SVPWM in DVR. The proposed control algorithm was investigated through computer simulation by using PSCAD/EMTDC software. Results: From simulation and experimental results showed the effectiveness and efficiency of the proposed controller based on SVPWM in mitigating voltage sags in low voltage distribution systems. It was concluded that its controller also works well both in balance and unbalance conditions of voltages. Conclusion/Recommendations: The simulation and experimental results of a DVR using PSCAD/EMTDC software based on SVPWM technique showed clearly the performance of the DVR in mitigating voltage sags. The DVR operates without any difficulties to inject the appropriate voltage component to correct rapidly any anomaly in the supply voltage to keep the

  15. Voltage Control for Unbalanced Low Voltage Grids Using a Decoupled-Phase On-Load Tap-Changer Transformer and Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Hu, Junjie

    2015-01-01

    more renewable generations in the LV grid. The potential benefits are investigated in terms of voltage unbalance reduction and local voltage regulation. 24-hours root-mean-square dynamics simulation studies have been carried out with timestep of 1 second using 10-mins resolution consumption...... and production profiles. A totally passive real Danish low voltage distribution network is used for the grid topology as well as for the characterization of loads profiles, while the production ones are empirically defined under assumptions in scenarios with different level of photovoltaic penetration and grade...

  16. Enhanced Control of a DFIG-Based Wind-Power Generation System With Series Grid-Side Converter Under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Yao, Jun; Li, Hui; Chen, Zhe

    2013-01-01

    This paper presents an enhanced control method for a doubly fed induction generator (DFIG)-based wind-power generation system with series grid-side converter (SGSC) under unbalanced grid voltage conditions. The behaviors of the DFIG system with SGSC during network unbalance are described. By inje......This paper presents an enhanced control method for a doubly fed induction generator (DFIG)-based wind-power generation system with series grid-side converter (SGSC) under unbalanced grid voltage conditions. The behaviors of the DFIG system with SGSC during network unbalance are described....... By injecting a series control voltage generated from the SGSC to balance the stator voltage, the adverse effects of voltage unbalance upon the DFIG, such as stator and rotor current unbalances, electromagnetic torque, and power pulsations, can be removed, and then the conventional vector control strategy...... for the rotor-side converter remains in full force under unbalanced conditions. Meanwhile, three control targets for the parallel grid-side converter (PGSC) are identified, including eliminating the oscillations in the total active power or reactive power, or eliminating negative-sequence current injected...

  17. Control of Magnetic Bearings for Rotor Unbalance With Plug-In Time-Varying Resonators.

    Science.gov (United States)

    Kang, Christopher; Tsao, Tsu-Chin

    2016-01-01

    Rotor unbalance, common phenomenon of rotational systems, manifests itself as a periodic disturbance synchronized with the rotor's angular velocity. In active magnetic bearing (AMB) systems, feedback control is required to stabilize the open-loop unstable electromagnetic levitation. Further, feedback action can be added to suppress the repeatable runout but maintain closed-loop stability. In this paper, a plug-in time-varying resonator is designed by inverting cascaded notch filters. This formulation allows flexibility in designing the internal model for appropriate disturbance rejection. The plug-in structure ensures that stability can be maintained for varying rotor speeds. Experimental results of an AMB-rotor system are presented.

  18. The Effect of Flywheel Unbalance on Gear Noise in the Hydraulic Power Plant Turbo-Generator

    Directory of Open Access Journals (Sweden)

    Tomeh Elias

    2017-01-01

    Full Text Available The Effect of Flywheel Unbalance on Gear Noise in the Hydraulic Power Plant Turbo-Generator. Hydraulic power plants are systems that produce electrical energy with high investment costs. In order to fulfil their goals, investments should create conditions for a safe production of energy in a long lasting and reliable way, and with the required power and quality. These goals are possible to reach by an optional control process linked to a systematic monitoring of the operating machinery state, using the method of vibration diagnostics. Lately, there has been an increase of noise level in the hydraulic power plants.

  19. Modeling and Capacitors Voltage Balancing Control of STATCOM Based on Modular Multilevel Converter

    Directory of Open Access Journals (Sweden)

    Milad Samady Shadlu

    2016-12-01

    Full Text Available Modular multilevel converter (MMC provides a new concept in a wide range of applications due to its simple topology and high reliability. In this paper, a three phase four legs modular multilevel converter is used as a compensator in a four-wire network which feeds an unbalanced and distorted custom load. The purpose is to compensate this unbalance load currents by injection suitable currents besides the capacitors voltage balancing control in individual legs. In this paper, designing of compensator current controller will be done based on a composite control model (CCM combined of average model and predictive control method. Also an independent controller has been proposed for capacitors voltage balancing whose task is to eliminate the circulating current oscillations in each leg. In order to control total energy stored in converter and also to remove the zero sequence current, two simple control schemes have been presented based on PI controller and closed loop controller, respectively. Finally simulation results have been presented in MATLAB/Simulink to confirm effectiveness and accuracy of proposed controller.

  20. Unbalance Response Analysis and Experimental Validation of an Ultra High Speed Motor-Generator for Microturbine Generators Considering Balancing

    Directory of Open Access Journals (Sweden)

    Do-Kwan Hong

    2014-08-01

    Full Text Available The objective of the present study was to deal with the rotordynamics of the rotor of an ultra-high speed PM type synchronous motor-generator for a 500 W rated micro gas turbine generator. This paper introduces dynamic analysis, and experiments on the motor-generator. The focus is placed on an analytical approach considering the mechanical dynamic problems. It is essential to deal with dynamic stability at ultra-high speeds. Unbalance response analysis is performed by calculating the unbalance with and without balancing using a balancing machine. Critical speed analysis is performed to determine the operating speed with sufficient separation margin. The unbalance response analysis is compared with the experimental results considering the balancing grade (ISO 1940-1 and predicted vibration displacement with and without balancing. Based on these results, a high-speed motor-generator was successfully developed.

  1. Unbalance response analysis and experimental validation of an ultra high speed motor-generator for microturbine generators considering balancing.

    Science.gov (United States)

    Hong, Do-Kwan; Joo, Dae-Suk; Woo, Byung-Chul; Koo, Dae-Hyun; Ahn, Chan-Woo

    2014-08-29

    The objective of the present study was to deal with the rotordynamics of the rotor of an ultra-high speed PM type synchronous motor-generator for a 500 W rated micro gas turbine generator. This paper introduces dynamic analysis, and experiments on the motor-generator. The focus is placed on an analytical approach considering the mechanical dynamic problems. It is essential to deal with dynamic stability at ultra-high speeds. Unbalance response analysis is performed by calculating the unbalance with and without balancing using a balancing machine. Critical speed analysis is performed to determine the operating speed with sufficient separation margin. The unbalance response analysis is compared with the experimental results considering the balancing grade (ISO 1940-1) and predicted vibration displacement with and without balancing. Based on these results, a high-speed motor-generator was successfully developed.

  2. Management of Power Quality Issues in Low Voltage Networks using Electric Vehicles: Experimental Validation

    DEFF Research Database (Denmark)

    Martinenas, Sergejus; Knezovic, Katarina; Marinelli, Mattia

    2017-01-01

    As Electric Vehicles (EVs) are becoming more wide spread, their high power consumption presents challenges for the residential low voltage networks, especially when connected to long feeders with unevenly distributed loads. However, if intelligently integrated, EVs can also partially solve...... and voltage unbalances by a local smart charging algorithm based on a droop controller. In order to validate this capability, a low-voltage grid with a share of renewable resources is recreated in SYSLAB PowerLabDK. The experimental results demonstrate the advantages of the intelligent EV charging...

  3. An equivalent unbalance identification method for the balancing of nonlinear squeeze-film damped rotordynamic systems

    Science.gov (United States)

    Torres Cedillo, Sergio G.; Bonello, Philip

    2016-01-01

    The high pressure (HP) rotor in an aero-engine assembly cannot be accessed under operational conditions because of the restricted space for instrumentation and high temperatures. This motivates the development of a non-invasive inverse problem approach for unbalance identification and balancing, requiring prior knowledge of the structure. Most such methods in the literature necessitate linear bearing models, making them unsuitable for aero-engine applications which use nonlinear squeeze-film damper (SFD) bearings. A previously proposed inverse method for nonlinear rotating systems was highly limited in its application (e.g. assumed circular centered SFD orbits). The methodology proposed in this paper overcomes such limitations. It uses the Receptance Harmonic Balance Method (RHBM) to generate the backward operator using measurements of the vibration at the engine casing, provided there is at least one linear connection between rotor and casing, apart from the nonlinear connections. A least-squares solution yields the equivalent unbalance distribution in prescribed planes of the rotor, which is consequently used to balance it. The method is validated on distinct rotordynamic systems using simulated casing vibration readings. The method is shown to provide effective balancing under hitherto unconsidered practical conditions. The repeatability of the method, as well as its robustness to noise, model uncertainty and balancing errors, are satisfactorily demonstrated and the limitations of the process discussed.

  4. UNBALANCE RESPONSE AND TOUCH-RUBBING THRESHOLD SPEED OF ROTOR SUBJECTED TO NONLINEAR MAGNETIC FORCES

    Institute of Scientific and Technical Information of China (English)

    JING Minqing; LI Zixin; LUO Min; YU Lie

    2008-01-01

    Because of the effect of unbalance excitation and nonlinear magnetic force, the large vibration of the rotor supported by active magnetic bearing(AMB) will go beyond the radial gap of the bearing, even causing mechanical touch-rubbing when the system works at an operational speed closer to the critical speed. In order to investigate this problem, the linear model and nonlinear model of the single mass symmetric rigid rotor system supported by AMB are established respectively and the corresponding transfer functions of close-loop system are given. To pass through the numerical calculation by using MATLAB/Simulink, the effect of both the unbalance response and threshold speed of touch-rubbing of the system subjected to nonlinear magnetic forces and nonlinear output current of power amplifier are studied. Furthermore, threshold speed of touch-rubbing of the rotor-bearing system is defined and the results of numerical simulation are presented. Finally, based on above studies, two methods of increasing the touch-rubbing threshold speed are discussed.

  5. Low Frequency Noise Degradation in 45 nm High-k nMOSFETs due to Hot Carrier and Constant Voltage Stress

    Science.gov (United States)

    Rahman, M. Shahriar; ćelik-Butler, Zeynep; Quevedo-Lopez, M. A.; Shanware, Ajit; Colombo, Luigi

    2009-04-01

    Hafnium based materials are the leading candidates to replace conventional SiON as the gate dielectric in complementary metal-oxide-semiconductor devices. Hot carrier and constant voltage stress induced 1/f noise behavior is presented for HfSiON nMOSFETs. The additional low-frequency noise introduced through stressing was evaluated on nMOSFETs with TiN metal gate and HfSiON gate dielectric. Nitridation of HfSiO was achieved either by high temperature thermal nitridation or by relatively lower temperature plasma nitridation. The difference in stress induced noise behavior is attributed to the nitrogen profile across high-k/Si interface and bulk of high-k gate oxide caused by different nitridation techniques.

  6. Phase-lock loop of Grid-connected Voltage Source Converter under non-ideal grid condition

    DEFF Research Database (Denmark)

    Wang, Haojie; Sun, Hai; Han, Minxiao;

    2015-01-01

    phase information cannot be accurately tracked. Based on analysis of the cause of double-frequency ripple when unbalance exists in main grid, a phase-locked loop (PLL) detection technique is proposed. Under the conditions of unsymmetrical system voltage, varying system frequency, single-phase system......It is a normal practice that the DC micro-grid is connected to AC main grid through Grid-connected Voltage Source Converter (G-VSC) for voltage support. Accurate control of DC micro-grid voltage is difficult for G-VSC under unbalanced grid condition as the fundamental positive-sequence component...

  7. Dynamic unbalance detection of cardan shaft in high-speed train based on EMD-SVD-NHT

    Institute of Scientific and Technical Information of China (English)

    丁建明; 林建辉; 何刘; 赵洁

    2015-01-01

    Contrary to the aliasing defect between the adjacent intrinsic model functions (IMFs) existing in empirical model decomposition (EMD), a new method of detecting dynamic unbalance with cardan shaft in high-speed train was proposed by applying the combination between EMD, Hankel matrix, singular value decomposition (SVD) and normalized Hilbert transform (NHT). The vibration signals of gimbal installed base were decomposed through EMD to get different IMFs. The Hankel matrix constructed through the single IMF was orthogonally executed through SVD. The critical singular values were selected to reconstruct vibration signs on the basis of the key stack of singular values. Instantaneous frequencys (IFs) of reconstructed vibration signs were applied to detect dynamic unbalance with shaft and eliminated clutter spectrum caused by the aliasing defect between the adjacent IMFs, which highlighted the failure characteristics. The method was verified by test data in the unbalance condition of dynamic cardan shaft. The results show that the method effectively detects the fault vibration characteristics caused by cardan shaft dynamic unbalance and extracts the nature vibration features. With comparison to the traditional EMD-NHT, clarity and failure characterization force are significantly improved.

  8. Far-end Crosstalk Modeling Based on Capacitive and Inductive Unbalances Between Pairs in a Cable

    Directory of Open Access Journals (Sweden)

    Pavel Lafata

    2011-01-01

    Full Text Available This article deals with new ways of far-end crosstalk (FEXT modeling in multi-pair and multi-quad metallic cables. Current standard modeling methods provide only rough estimations of FEXT characteristics based on average values of crosstalk for the whole cable. However, for practical implementation of vector discrete multi-tone modulation (VDMT is necessary to predict and simulate FEXT characteristics with sufficient accuracy and simulate FEXT transfer functions individually for each combination of symmetrical pairs in a cable. This article contains a theoretical analysis and description of the problem and suggests a new method for modeling of FEXT crosstalk using capacitive and inductive unbalances between pairs in a cable. This proposed model offers more accurate and realistic results of crosstalk. Theoretical simulations and results are also compared with the measured characteristics for specific metallic cable.

  9. Unequal Input Voltages Distribution Between the Serial Connected Halfbridges

    Directory of Open Access Journals (Sweden)

    Radovan Ovcarcik

    2006-01-01

    Full Text Available This paper describes a topology of DC-DC converter consisting in two serial connected half-bridges. Secondary circuit is realized like a conventional full-wave rectifier. The main advantage of this topology is the possibility of dividing the input voltage between the half-bridges. The converter is controlled using the phase-shift modulation, which allows a ZVSoperation mode. The voltage unbalance between the inputs causes an important problem of the presented topology. It is necessary to avoid it by the control algorithm, which is described in the text. The practical results show a zero voltage switching technique and the limits of the chosen topology and of the control.

  10. Mitigation of Voltage Sags in CIGRE Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar;

    2013-01-01

    problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate voltage sags in the CIGRE Low Voltage (LV) test network and networks like this. The voltage sags, for the tested cases in the CIGRE LV test network are mainly due to three phase faults....... The compensation of voltage sags in the different parts of CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0....

  11. Improved Control Strategies for a DFIG-Based Wind-Power Generation System with SGSC under Unbalanced and Distorted Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Yao, Jun; Yu, Mengting; Hu, Weihao

    2016-01-01

    This paper investigates an improved control strategy for a doubly-fed induction generator (DFIG) based wind-power generation system with series grid-side converter (SGSC) under network unbalance and harmonic grid voltage distortion conditions. The integrated mathematical modeling of the DFIG system...... with SGSC is established by taking both the negative-sequence and harmonic components of the grid voltages into consideration with multiple synchronous rotating reference frames. Under network unbalance and harmonic distortion situations, stator voltage can be kept symmetrical and sinusoidal by the control...... references are calculated. In addition, the allocation principles for the PGSC’s current references are proposed by taking into account the PGSC's current rating limit. The impact of PGSC’s current limit on the proposed control strategies have been investigated in detail. Furthermore, a PI regulator...

  12. Correlation between arterial blood gas analysis and peripheral blood gas analysis in acid-base unbalance state

    Directory of Open Access Journals (Sweden)

    Hyun Lee Kim

    2012-06-01

    Full Text Available Acid-base unbalance is most common problem in severe ill patient, especially in condition of abnormal renal function state. Acid-base unbalances are respiratory acidosis, respiratory alkalosis, metabolic acidosis, and metabolic alkalosis. Metabolic acidosis is frequently appeared in clinical state. Arterial blood gas analysis is considered as a basic test to the intensive care unit patient and emergency state. Recently some researches were done, comparing with arterial blood gas analysis and venous blood gas analysis. Because of venous blood sampling is safer than arterial blood gas analysis, and beside not so different among them for detecting pH, pCO2, HCO3, except pO2 measuring. This research was done in emergency room, and for explaining no different between arterial blood gas analysis and peripheral blood gas analysis result in acid-base unbalance state patient. Especially in kidney functions decreased state. : The study was done from March, 2010 to January, 2011. The object was 89 peoples who came to emergency room for treating internal medicine problem. (Women 53, average age: 66.7±12.1 Then compare between arterial blood gas analysis and peripheral blood gas analysis. Result: The mean arterial minus venous difference for pH, pCO2, and bicarbonate was −0.0170, 2.6528, and 0.6124. Bland-Altman plot was done for predicting agreement of two groups, and the scale was pH −2.95 to 4.17, pCO2 −4.45 to 9.76, bicarbonate −2.95 to 4.16, in 95% relative. Conclusion: The peripheral blood gas pH, pCO2, bicarbonate level is almost same as arterial blood gas analysis results. And enough to measuring acid-base unbalance state, in absent of arterial blood testing.

  13. Uncertainty Assessment on Failure Accident of Voltage-Sensitive Equipment Due to Voltage Sag by Maximum Hybrid Entropy%敏感设备电压暂降失效事件不确定性的最大混合熵评估

    Institute of Scientific and Technical Information of China (English)

    汪颖; 肖先勇; 杨达

    2012-01-01

    敏感设备电压暂降失效事件是混合不确定事件,对其评估需考虑混合不确定性.以混合熵作为评价测度,建立敏感设备电压暂降失效事件不确定性的最大混合熵评估模型,并用以逆积法为基础的多阶段改进近似规划法进行模型求解.在评估过程中,将混合不确定性分解为随机性、模糊性和两者的交叉不确定性,并用随机商、模糊熵和交叉熵进行量化.以计算机(personal computer,PC)为例,考虑到PC机在电压暂降发生前可能处于全速、空载和正常等运行状态,电压暂降发生后可能出现完全死机、运算出错和“假死”等不同严重程度的失效状态,对实测样本进行评估,并与概率法、模糊法比较,结果证明,该方法所得结果客观、可行,克服了现有方法过估计或欠估计等不足,结果更符合实际.%The failure accident of voltage-sensitive equipments due to voltage sag is a hybrid uncertainty accident. Taking hybrid entropy as assessment measure a maximum hybrid entropy-based uncertainty assessment model for failure accident of voltage-sensitive equipments due to voltage sag is established and solved by multi-stage improved approximate programming. During the assessment the hybrid uncertainty is decomposed to stochastic uncertainty, fuzzy uncertainty and the crossed certainty of the both, and these uncertainties are quantized by stochastic entropy, fuzzy entropy and crossed entropy. Taking personal computer (PC) as the case and considering possible operation conditions of PC before the occurrence of voltage sag, namely full speed running, no-load and normal operation, after the occurrence of voltage sag following failure states in different severities such as PC system halt, calculation error and false system halt may occur. The measured samples are assessed and the assessment results are compared with those assessed by probabilistic assessment and fuzzy assessment. Comparison results show that

  14. Design of Robust Adaptive Unbalance Response Controllers for Rotors with Magnetic Bearings

    Science.gov (United States)

    Knospe, Carl R.; Tamer, Samir M.; Fedigan, Stephen J.

    1996-01-01

    Experimental results have recently demonstrated that an adaptive open loop control strategy can be highly effective in the suppression of unbalance induced vibration on rotors supported in active magnetic bearings. This algorithm, however, relies upon a predetermined gain matrix. Typically, this matrix is determined by an optimal control formulation resulting in the choice of the pseudo-inverse of the nominal influence coefficient matrix as the gain matrix. This solution may result in problems with stability and performance robustness since the estimated influence coefficient matrix is not equal to the actual influence coefficient matrix. Recently, analysis tools have been developed to examine the robustness of this control algorithm with respect to structured uncertainty. Herein, these tools are extended to produce a design procedure for determining the adaptive law's gain matrix. The resulting control algorithm has a guaranteed convergence rate and steady state performance in spite of the uncertainty in the rotor system. Several examples are presented which demonstrate the effectiveness of this approach and its advantages over the standard optimal control formulation.

  15. 无功和三相负荷不平衡的序分量法补偿控制%Compensation control of reactive power and three-phase unbalance load based on the method of sequence component

    Institute of Scientific and Technical Information of China (English)

    辛业春; 李国庆; 王朝斌

    2014-01-01

    A static synchronous compensator (STATCOM) is used into distribution grid for compensating reactive power and three- phase unbalance load for the distribution grid. According to analyzing the positive sequence equivalent circuit and negative sequence equivalent circuit under the three-phase unbalance load of distribution grid, using the symmetrical component method and superposition principle, a new cascade loop control strategy of positive sequence current and negative sequence current is proposed. Usingδ-θ control, the positive sequence loop compensates reactive power of distribution grid and maintains stability of STATCOM DC voltage. Usingφ-θ control in the negative sequence loop can make STATCOM compensate negative-sequence current caused by three-phase load unbalance and keep distribution grid side three-phase load balanced. Simulation and experiment results are presented to verify the validity of the proposed control strategy. This work is supported by National Natural Science Foundation of China (No. 51377016).%将静止同步补偿器(Static Synchronous Compensator,STATCOM)并入电网来补偿无功功率和配电网三相负荷不平衡。通过对称分量法和叠加原理,对配电网三相负荷不平衡情况下正序、负序等效电路进行分析,提出一种新的正、负序补偿电流叠加补偿控制方法。正序控制环采用δ-θ控制,实现配电网无功功率补偿和保持STATCOM直流侧电压稳定;负序控制环采用φ-θ控制,实现STATCOM补偿三相负荷不平衡产生的负序电流,使电网侧三相负荷保持平衡。仿真和实验结果表明,该方法可以有效地补偿电网无功功率和三相负荷不平衡。

  16. Design of High Randomness PUF Circuit Based on Bridge Unbalance Effect%基于电桥失衡效应的高随机性PUF电路设计

    Institute of Scientific and Technical Information of China (English)

    钱浩宇; 汪鹏君; 李刚

    2016-01-01

    通过对物理不可克隆函数(Physical Unclonable Functions, PUF)电路和电桥失衡效应的研究,提出一种高随机性 PUF 电路设计方案.该方案首先利用工艺偏差导致电桥失衡产生随机偏差电压,然后结合电压型灵敏放大器产生随机的、不可克隆的响应信号.在TSMC 65nm CMOS工艺下,采用全定制方法设计PUF电路, PUF单元电路的版图面积为2.23µm×2.43µm.通过Spectre软件,在不同电压下对所设计PUF电路进行Monte Carlo仿真验证,分析其逻辑功能、随机性等特性.实验结果表明:所设计的PUF电路在电源电压1.2 V和温度25℃下随机性可达51.8%.%Through researching on the physical unclonable function (PUF) circuit and bridge unbalance effect, a high randomness PUF circuit is proposed in this paper. In this scheme, random deviation voltages are generated from bridge unbalance caused by process deviation. Then, random deviation voltages are inputted into sense amplifier to obtain response which is random and unclonable. Under TSMC 65nm CMOS process, the full custom design method is adopted. The layout area of PUF circuit is 2.23µm×2.43µm. Using Spectre software, Monte Carlo simulation results verify the designed PUF circuit under different voltage conditions. And also, the logical function and random characteristics are analyzed based on the simulation results. At 1.2V & 25℃, the randomness of the proposed PUF circuit achieves 51.8%.

  17. 《聚会》中家庭伦理的迷失%Study on the Unbalance of Family Ethics in The Gathering

    Institute of Scientific and Technical Information of China (English)

    侯茜希

    2014-01-01

    安•恩莱特在《聚会》中讲述了一个家庭三代人由于爱的缺失而导致的悲剧命运,它呈现出现代文明中两性之间、亲子之间、手足之间以及自我之间爱的缺失,表达了对家庭伦理失衡的忧思以及对健康家庭伦理的诉求。在恩莱特看来,“爱”是家庭伦理的核心原则,是救赎伤痛的良药。%In her novel The Gathering, Anne Enright narrates the tragic destinies of three generations in a big family due to lack of love. Enright expresses her worries about the unbalance of family ethics and appeal for healthy family ethics in modern civilization by describing the lack of“love”between two genders, parents and children and siblings as well as love toward oneself. For Enright,“love”is the central principle of family ethics and the remedy for hurts.

  18. Voltage Dependence of Supercapacitor Capacitance

    Directory of Open Access Journals (Sweden)

    Szewczyk Arkadiusz

    2016-09-01

    Full Text Available Electronic Double-Layer Capacitors (EDLC, called Supercapacitors (SC, are electronic devices that are capable to store a relatively high amount of energy in a small volume comparing to other types of capacitors. They are composed of an activated carbon layer and electrolyte solution. The charge is stored on electrodes, forming the Helmholtz layer, and in electrolyte. The capacitance of supercapacitor is voltage- dependent. We propose an experimental method, based on monitoring of charging and discharging a supercapacitor, which enables to evaluate the charge in an SC structure as well as the Capacitance-Voltage (C-V dependence. The measurement setup, method and experimental results of charging/discharging commercially available supercapacitors in various voltage and current conditions are presented. The total charge stored in an SC structure is proportional to the square of voltage at SC electrodes while the charge on electrodes increases linearly with the voltage on SC electrodes. The Helmholtz capacitance increases linearly with the voltage bias while a sublinear increase of total capacitance was found. The voltage on SC increases after the discharge of electrodes due to diffusion of charges from the electrolyte to the electrodes. We have found that the recovery voltage value is linearly proportional to the initial bias voltage value.

  19. A SVPWM based on fluctuate capacitor voltage in 3L-NPC back-to-back converter applied to wind energy

    DEFF Research Database (Denmark)

    Chen, Quan; Wang, Qunjing; Chen, Zhe

    2014-01-01

    Three-level Neutral-point-clamped (3L-NPC) converters are becoming a realistic alternative to the conventional converters in high-power wind-energy applications. But the unbalance in the supported capacitors' voltage of back-to-back 3L-NPC converters, including the dynamics of the capacitors...... between the fluctuate voltage of upper and lower capacitors is extracted. Based on this error factor the duty-time of every active voltage vector is calculated. In order to validate the model and the control strategy proposed in this paper, a 2MW 3L-NPC converter used in wind energy has been simulated....

  20. Discrete-Time Domain Modelling of Voltage Source Inverters in Standalone Applications: Enhancement of Regulators Performance by Means of Smith Predictor

    DEFF Research Database (Denmark)

    Federico, de Bosio; de Sousa Ribeiro, Luiz Antonio; Freijedo Fernandez, Francisco Daniel

    2017-01-01

    and Smith predictor design, respectively, are obtained. Subsequently, the voltage regulator is also designed for a wide bandwidth, which permits the inclusion of resonant filters for the steady-state mitigation of odd harmonics at nonlinear unbalance load terminals. Discrete-time domain implementation......The decoupling of the capacitor voltage and inductor current has been shown to improve significantly the dynamic performance of voltage source inverters in standalone applications. However, the computation and PWM delays still limit the achievable bandwidth. In this paper a discrete-time domain...

  1. Accurate Switched-Voltage voltage averaging circuit

    OpenAIRE

    金光, 一幸; 松本, 寛樹

    2006-01-01

    Abstract ###This paper proposes an accurate Switched-Voltage (SV) voltage averaging circuit. It is presented ###to compensated for NMOS missmatch error at MOS differential type voltage averaging circuit. ###The proposed circuit consists of a voltage averaging and a SV sample/hold (S/H) circuit. It can ###operate using nonoverlapping three phase clocks. Performance of this circuit is verified by PSpice ###simulations.

  2. Satellite Jitter Analysis Based on Unbalance of Flywheel%飞轮不平衡对卫星颤振影响分析

    Institute of Scientific and Technical Information of China (English)

    韩旭

    2012-01-01

    The models of static and dynamic unbalance of flywheel were established based on the principle of the static and dynamic unbalance of satellite in this paper. The simulation was made according to the models set up. The results showed that the static unhalance was 2 orders more than the dynamic unbalance for the flywheel, which was the major jitter source.%基于卫星飞轮的静动不平衡原理,对飞轮的静动不平衡进行了建模。根据建立的整星动力学模型进行了仿真分析。结果表明:飞轮的静不平衡对整星的扰动较动不平衡大2个量级,是主要的颤振激励源。

  3. Proposal to use vibration analysis steering components and car body to monitor, for example, the state of unbalance wheel

    Science.gov (United States)

    Janczur, R.

    2016-09-01

    The results of road tests of car VW Passat equipped with tires of size 195/65 R15, on the influence of the unbalancing front wheel on vibration of the parts of steering system, steering wheel and the body of the vehicle have been presented in this paper. Unbalances wheels made using weights of different masses, placed close to the outer edge of the steel rim and checked on the machine Hunter GSP 9700 for balancing wheels. The recorded waveforms vibration steering components and car body, at different constant driving speeds, subjected to spectral analysis to determine the possibility of isolating vibration caused by unbalanced wheel in various states and coming from good quality asphalt road surface. The results were discussed in terms of the possibility of identifying the state of unbalancing wheels and possible changes in radial stiffness of the tire vibration transmitted through the system driving wheel on the steering wheel. Vibration analysis steering components and car body, also in the longitudinal direction, including information from the CAN bus of the state of motion of the car, can be used to monitor the development of the state of unbalance wheel, tire damage or errors shape of brake discs or brake drums, causing pulsations braking forces.

  4. Tumor Necrosis Factor Is a Therapeutic Target for Immunological Unbalance and Cardiac Abnormalities in Chronic Experimental Chagas' Heart Disease

    Science.gov (United States)

    Pereira, Isabela Resende; Vilar-Pereira, Glaucia; Silva, Andrea Alice; Moreira, Otacilio Cruz; Britto, Constança; Sarmento, Ellen Diana Marinho

    2014-01-01

    Background. Chagas disease (CD) is characterized by parasite persistence and immunological unbalance favoring systemic inflammatory profile. Chronic chagasic cardiomyopathy, the main manifestation of CD, occurs in a TNF-enriched milieu and frequently progresses to heart failure. Aim of the Study. To challenge the hypothesis that TNF plays a key role in Trypanosoma cruzi-induced immune deregulation and cardiac abnormalities, we tested the effect of the anti-TNF antibody Infliximab in chronically T. cruzi-infected C57BL/6 mice, a model with immunological, electrical, and histopathological abnormalities resembling Chagas' heart disease. Results. Infliximab therapy did not reactivate parasite but reshaped the immune response as reduced TNF mRNA expression in the cardiac tissue and plasma TNF and IFNγ levels; diminished the frequency of IL-17A+ but increased IL-10+ CD4+ T-cells; reduced TNF+ but augmented IL-10+ Ly6C+ and F4/80+ cells. Further, anti-TNF therapy decreased cytotoxic activity but preserved IFNγ-producing VNHRFTLV-specific CD8+ T-cells in spleen and reduced the number of perforin+ cells infiltrating the myocardium. Importantly, Infliximab reduced the frequency of mice afflicted by arrhythmias and second degree atrioventricular blocks and decreased fibronectin deposition in the cardiac tissue. Conclusions. Our data support that TNF is a crucial player in the pathogenesis of Chagas' heart disease fueling immunological unbalance which contributes to cardiac abnormalities. PMID:25140115

  5. Voltage Sensors Monitor Harmful Static

    Science.gov (United States)

    2009-01-01

    A tiny sensor, small enough to be worn on clothing, now monitors voltage changes near sensitive instruments after being created to alert Agency workers to dangerous static buildup near fuel operations and avionics. San Diego s Quasar Federal Systems received a Small Business Innovation Research (SBIR) contract from Kennedy Space Center to develop its remote voltage sensor (RVS), a dime-sized electrometer designed to measure triboelectric changes in the environment. One of the unique qualities of the RVS is that it can detect static at greater distances than previous devices, measuring voltage changes from a few centimeters to a few meters away, due to its much-improved sensitivity.

  6. Performance Analysis of Error Probabilities for Arbitrary 2-D Signaling with I/Q Unbalances over Nakagami-m Fading Channels

    Science.gov (United States)

    Lee, Jaeyoon; Yoon, Dongweon; Park, Sang Kyu

    Recently, we provided closed-form expressions involving two-dimensional (2-D) joint Gaussian Q-function for the symbol error rate (SER) and bit error rate (BER) of an arbitrary 2-D signal with I/Q unbalances over an additive white Gaussian noise (AWGN) channel [1]. In this letter, we extend the expressions to Nakagami-m fading channels. Using Craig representation of the 2-D joint Gaussian Q-function, we derive an exact and general expression for the error probabilities of arbitrary 2-D signaling with I/Q phase and amplitude unbalances over Nakagami-m fading channels.

  7. Diagnosis of stator faults in induction motor based on zero sequence voltage after switch-off

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    To improve the accuracy of the stator winding fault diagnosis in induction motor, a new diagnostic method based on the Hilbert-Huang transform (HHT) was proposed. The ratio of fundamental zero sequence voltage to positive sequence voltage after switch-offwas selected as the stator fault characteristic, which could effectively avoid the influence of the supply unbalance and the load fluctuation, and directly represent the asymmetry in the stator. Using the empirical mode decomposition (EMD) based on HHT, the zero sequence voltage after switch-off was decomposed and the fundamental component was extracted. Then, the fault characteristic can be acquired. Experimental results on a 4-kW induction motor demonstrate the feasibility and effectiveness of this method.

  8. A sensorless control method for capacitor voltage balance and circulating current suppression of modular multilevel converter

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang

    2015-01-01

    There are several problems in the Modular Multilevel Converter (MMC), such as the appearance of circulating current, capacitor voltage unbalance and the requirement for a high number of sensors. All these problems will decrease the reliability and raise the cost/uncertainty of using MMC solutions....... As a result, a sensorless control method is proposed in this paper, which targets to improve the performances of MMC in respect to the above mentioned disadvantages: To decrease the cost and simplify the physical implementation, a state observer is proposed and designed to estimate both the capacitor voltages...... and the circulating currents in order to replace the high numbers of sensors. Furthermore, a control method combining the circulating current suppression and the capacitor voltage balancing is conducted based on the proposed state observer. It is concluded that the proposed state observer and control method can...

  9. Distributed Active Synchronization Strategy for Microgrid Seamless Reconnection to the Grid under Unbalance and Harmonic Distortion

    DEFF Research Database (Denmark)

    Tang, Fen; Guerrero, Josep M.; Vasquez, Juan Carlos

    2015-01-01

    Microgrids can operate in both grid-connected and islanded modes. In order to seamlessly transfer from islanded to grid-connected modes, it is necessary to synchronize microgrid voltage, frequency and phase to the main grid. However, since the microgrid is often based on power electronics...... converters, the synchronization process is quite different compared to the quasi-synchronism control in conventional power systems. Firstly, in order to address this concern, the microgrid synchronization criteria are derived. Based on these criteria, a novel distributed active synchronization strategy...

  10. Tools for the analysis of technical and economical impacts due to budgetary restrictions in investments plans of high voltage systems; Ferramenta para analise dos impactos tecnicos e economicos por restricoes orcamentarias em planos de investimentos de sistemas de alta tensao

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Josinaldo; Freire, Kleber [Universidade de Salvador (UNIFACS), BA (Brazil)]. E-mails: josinaldo@luar.nlink.com.br; kfreire@unifacs.br; Antunes, Alden; Kagan, Henrique; Guaraldo, Joao [Daimon Interplan, Sao Paulo, SP (Brazil)]. E-mails: alden@daimoninterplan.com.br; henkagan@uol.com.br; guaraldo@daimoninterplan.com.br; Kagan, Nelson [Universidade de Sao Paulo (USP), SP (Brazil). Escola Politecnica]. E-mail: nelsonk@pea.usp.br; Silveira, Cristiano [Universidade de Sao Paulo (USP), SP (Brazil). Escola Politecnica. Centro de Estudos em Regulacao e Qualidade de Energia (ENERQ)]. E-mail: cristiano@pea.usp.br

    2006-07-01

    This article deals with a computational module conceived to make possible the treatment of the problem of cut of workman ships in the segment of high-voltage distribution, motivated for budgetary restrictions. For this computational module it is possible, from a set of workmanship candidates, to effect the evaluation of the respective operational performance of the current system of the insertion of workmanship (considering adequate models of power flow and high-voltage trustworthiness of nets), respective economic valuation and posterior prioritization (for in such a way, using based appropriate techniques of optimization in genetic algorithms), respecting it considered budgetary availability. In this context, the developed computational module aims at to guide the planner in the task to discard workmanship, searching to minimize the corresponding technician-economic impact. (author)

  11. Control of a Modular Multilevel Converter STATCOM under internal and external unbalances

    DEFF Research Database (Denmark)

    Tsolaridis, Georgios; Kontos, E.; Parikh, Harsh;

    2016-01-01

    This paper develops a complete control scheme for the Modular Multilevel Converter (MMC) in a STATCOM application. The focus is laid on the internal balancing of the converter and its reliable operation under internal mismatches as well as under external unbalanced conditions. The leg energy...... controller ensures that the sum of the capacitor voltages of each phase are equal. An intuitive arm energy controller is also implemented which allows the decoupled control of the energy levels of every arm. The control performance of the STATCOM was evaluated under asymmetrical grid faults...... and the simulation results verified the capability to provide maximum reactive power to the AC grid while maintaining internal balance through the individual control of each arm energy level....

  12. Control of a Modular Multilevel Converter STATCOM under internal and external unbalances

    DEFF Research Database (Denmark)

    Tsolaridis, Georgios; Kontos, E.; Parikh, Harsh

    2016-01-01

    This paper develops a complete control scheme for the Modular Multilevel Converter (MMC) in a STATCOM application. The focus is laid on the internal balancing of the converter and its reliable operation under internal mismatches as well as under external unbalanced conditions. The leg energy...... and the simulation results verified the capability to provide maximum reactive power to the AC grid while maintaining internal balance through the individual control of each arm energy level....... controller ensures that the sum of the capacitor voltages of each phase are equal. An intuitive arm energy controller is also implemented which allows the decoupled control of the energy levels of every arm. The control performance of the STATCOM was evaluated under asymmetrical grid faults...

  13. Transient Voltage Recorder

    Science.gov (United States)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    2002-01-01

    A voltage transient recorder can detect lightning induced transient voltages. The recorder detects a lightning induced transient voltage and adjusts input amplifiers to accurately record transient voltage magnitudes. The recorder stores voltage data from numerous monitored channels, or devices. The data is time stamped and can be output in real time, or stored for later retrieval. The transient recorder, in one embodiment, includes an analog-to-digital converter and a voltage threshold detector. When an input voltage exceeds a pre-determined voltage threshold, the recorder stores the incoming voltage magnitude and time of arrival. The recorder also determines if its input amplifier circuits clip the incoming signal or if the incoming signal is too low. If the input data is clipped or too low, the recorder adjusts the gain of the amplifier circuits to accurately acquire subsequent components of the lightning induced transients.

  14. Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions

    Institute of Scientific and Technical Information of China (English)

    Jia-bing HU; Yi-kang HE; Lie XU

    2008-01-01

    This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed in-duction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positive and negative synchronous reference frames is presented. Variations of the stator output active and reactive powers are fully deduced in the presence of negative sequence supply voltage and rotor flux. An enhanced DPC scheme is proposed to eliminate stator active power oscillation during network unbalance. The proposed control scheme removes rotor current regulators and the decomposition processing of positive and negative sequence rotor currents. Simulation results using PSCAD/EMTDC are presented on a 2-MW DFIG wind power generation system to validate the feasibility of the proposed control scheme under balanced and unbalanced network conditions.

  15. Automatic voltage imbalance detector

    Science.gov (United States)

    Bobbett, Ronald E.; McCormick, J. Byron; Kerwin, William J.

    1984-01-01

    A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

  16. Mixed voltage VLSI design

    Science.gov (United States)

    Panwar, Ramesh; Rennels, David; Alkalaj, Leon

    1993-01-01

    A technique for minimizing the power dissipated in a Very Large Scale Integration (VLSI) chip by lowering the operating voltage without any significant penalty in the chip throughput even though low voltage operation results in slower circuits. Since the overall throughput of a VLSI chip depends on the speed of the critical path(s) in the chip, it may be possible to sustain the throughput rates attained at higher voltages by operating the circuits in the critical path(s) with a high voltage while operating the other circuits with a lower voltage to minimize the power dissipation. The interface between the gates which operate at different voltages is crucial for low power dissipation since the interface may possibly have high static current dissipation thus negating the gains of the low voltage operation. The design of a voltage level translator which does the interface between the low voltage and high voltage circuits without any significant static dissipation is presented. Then, the results of the mixed voltage design using a greedy algorithm on three chips for various operating voltages are presented.

  17. Effects of pacing, status and unbalance in time motion variables, heart rate and tactical behaviour when playing 5-a-side football small-sided games.

    Science.gov (United States)

    Sampaio, Jaime E; Lago, Carlos; Gonçalves, Bruno; Maçãs, Victor M; Leite, Nuno

    2014-03-01

    To compare time-motion variables, heart rate and players' tactical behaviour according to game pace (slow, normal or fast), status (winning and losing) and team unbalance (superiority and inferiority) in football 5-a-side small-sided games. To identify the most discriminating variables in classifying performances according to these constraints. Cross-sectional field study. The data were gathered using global positioning systems (5 Hz) in 5-a-side small-sided games (7 × 5 min) played by twenty-four footballers. The tactical performance was measured using dynamical positioning variables, processed by non-linear signal processing techniques (approximate entropy). ANOVA models were used to compare between constraints and discriminant analyses to identify the variables that best discriminate between pacing and status × unbalance constraints. The fast paced games had the highest mean speed value, followed by normal and slow paced games (8.2 ± 0.6 km h(-1), 7.8 ± 0.5 km h(-1) and 6.2 ± 0.4 km h(-1), respectively). The stronger predictor variables of pacing were the randomness in distance to team centroid and the distances covered above 13 km h(-1). The results also changed according to game status and team unbalance. The strongest predictor variables were the distance covered below 6.9 km h(-1), distance and randomness to team centroid, with higher values when winning in superiority conditions. Practice task design manipulating game pace, status and team unbalance significantly influenced the emergent behavioural dynamics. Collective positioning variables were more accurate in discriminating these constraints and, therefore, need to be considered when planning and monitoring performance. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. Simulative and experimental investigation on stator winding turn and unbalanced supply voltage fault diagnosis in induction motors using Artificial Neural Networks.

    Science.gov (United States)

    Lashkari, Negin; Poshtan, Javad; Azgomi, Hamid Fekri

    2015-11-01

    The three-phase shift between line current and phase voltage of induction motors can be used as an efficient fault indicator to detect and locate inter-turn stator short-circuit (ITSC) fault. However, unbalanced supply voltage is one of the contributing factors that inevitably affect stator currents and therefore the three-phase shift. Thus, it is necessary to propose a method that is able to identify whether the unbalance of three currents is caused by ITSC or supply voltage fault. This paper presents a feedforward multilayer-perceptron Neural Network (NN) trained by back propagation, based on monitoring negative sequence voltage and the three-phase shift. The data which are required for training and test NN are generated using simulated model of stator. The experimental results are presented to verify the superior accuracy of the proposed method.

  19. Intracellular calcium elevation during plateau potentials mediated by extrasynaptic NMDA receptor activation in rat hippocampal CA1 pyramidal neurons is primarily due to calcium entry through voltage-gated calcium channels.

    Science.gov (United States)

    Oda, Yoshiaki; Kodama, Satoshi; Tsuchiya, Sadahiro; Inoue, Masashi; Miyakawa, Hiroyoshi

    2014-05-01

    We reported previously that plateau potentials mediated by extrasynaptic N-methyl-d-aspartate receptors (NMDARs) can be induced either by synaptic stimulation in the presence of glutamate transporter antagonist or by iontophoresis of NMDA in rat hippocampal CA1 pyramidal neurons. To examine whether the plateau potentials are accompanied by an elevation of intracellular Ca2+ and to determine the source of Ca2+ elevation, we performed Ca2+ imaging during the plateau potential. Neurons were loaded with Ca2+ indicator fluo-4, and the plateau potentials were generated either synaptically in the presence of glutamate transporter antagonist or by iontophoretically applying NMDA. We have found that a transient elevation in intracellular Ca2+ accompanies the plateau potential. The synaptically induced plateau potential and the Ca2+ elevation were blocked by 5,7-dichlorokynurenic acid (5,7-dCK), an antagonist for the glycine-binding sites of NMDAR. A mixture of Cd2+ and tetrodotoxin did not block NMDA-induced plateau potentials, but completely abolished the accompanying Ca2+ elevation in both the presence and absence of Mg2+ ions in the bathing solution. The NMDA-induced plateau potential was blocked by further adding 5,7-dCK. Our results show that the NMDAR-mediated plateau potential is accompanied by elevation of intracellular Ca2+ that is primarily caused by the influx of Ca2+ through voltage-gated Ca2+ channels. © 2014 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  20. Power Quality Improvement Using an Enhanced Network-Side-Shunt-Connected Dynamic Voltage Restorer

    Science.gov (United States)

    Fereidouni, Alireza; Masoum, Mohammad A. S.; Moghbel, Moayed

    2015-10-01

    Among the four basic dynamic voltage restorer (DVR) topologies, the network-side shunt-connected DVR (NSSC-DVR) has a relatively poor performance and is investigated in this paper. A new configuration is proposed and implemented for NSSC-DVR to enhance its performance in compensating (un)symmetrical deep and long voltage sags and mitigate voltage harmonics. The enhanced NSSC-DVR model includes a three-phase half-bridge semi-controlled network-side-shunt-connected rectifier and a three-phase full-bridge series-connected inverter implemented with a back-to-back configuration through a bidirectional buck-boost converter. The network-side-shunt-connected rectifier is employed to inject/draw the required energy by NSSC-DVR to restore the load voltage to its pre-fault value under sag/swell conditions. The buck-boost converter is responsible for maintaining the DC-link voltage of the series-connected inverter at its designated value in order to improve the NSSC-DVR capability in compensating deep and long voltage sags/swells. The full-bridge series-connected inverter permits to compensate unbalance voltage sags containing zero-sequence component. The harmonic compensation of the load voltage is achieved by extracting harmonics from the distorted network voltage using an artificial neural network (ANN) method called adaptive linear neuron (Adaline) strategy. Detailed simulations are performed by SIMULINK/MATLAB software for six case studies to verify the highly robustness of the proposed NSSC-DVR model under various conditions.

  1. Technological Aspects: High Voltage

    CERN Document Server

    Faircloth, D C

    2013-01-01

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered.

  2. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  3. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  4. A New Asymmetrical Current-fed Converter with Voltage Lifting

    Directory of Open Access Journals (Sweden)

    DELSHAD, M.

    2011-05-01

    Full Text Available This paper presents a new zero voltage switching current-fed DC-DC converter with high voltage gain. In this converter all switches (main and auxiliary turn on under zero voltage switching and turn off under almost zero voltage switching due to snubber capacitor. Furthermore, the voltage spike across the main switch due to leakage inductance of forward transformer is absorbed. The flyback transformer which is connected to the output in series causes to high voltage gain and less voltage stress on the power devices. Considering high efficiency and voltage gain of this converter, it is suitable for green generated systems such as fuel cells or photovoltaic systems. The presented experimental results verify the integrity of the proposed converter.

  5. Analysis of Torque Ripple Caused by Three-Phase Unbalance in Claw Teeth Motors

    Science.gov (United States)

    Koyama, Takayuki; Nakatsugawa, Junnosuke; Enomoto, Yuji

    A soft magnetic composite (SMC) has some advantages, namely, three-dimensional magnetic isotropy and low eddy current loss. Thus, it can be used to build a new type of motor with a three-dimensional structure, improved space factor of winding improved the power density. A claw teeth motor is one of the motors that have three-dimensional structure, and it is made of an SMC. Due to its structure, the claw teeth motor has an unbalanced three-phase magnetic circuit, which leads to low-order harmonic components in the torque waveform. For reducing the torque ripple, it is important to estimate the magnetic torque and the cogging torque because the total torque is the sum of these torques. In this study a method for decomposing the total torque under the load condition into the magnetic torque and cogging torque is presented. The proposed method can quantitatively estimate low-order harmonic components of the magnetic torque and cogging torque caused by an unbalanced three-phase magnetic circuit for each phase.

  6. VOLTAGE REGULATORS OF SYNCHRONOUS GENERATORS

    Directory of Open Access Journals (Sweden)

    Grigorash O. V.

    2015-06-01

    Full Text Available Synchronous generators are the primary source of electrical power autonomous electrosupply systems, including backup systems. They are also used in a structure of rotating electricity converters and are widely used in renewable energy as part of wind power plants of small, mini and micro hydroelectric plants. Increasing the speed and the accuracy of the system of the voltage regulation of synchronous generators is possible due to the development of combined systems containing more stabilizers. The article illustrates the functional schemes of circuit voltage stabilizers and frequency synchronous generators (with electromagnetic excitation and permanent magnet excitation and describes the features of their work, including two and three-aggregate rotating converters of electricity used in uninterruptible power supply systems. To improve the technical characteristics of the system of stabilization we have proposed functional solutions for stabilizers of synchronous generators made on the base of direct frequency converters and using a transformer with a rotating magnetic field. To improve the reliability of and to improve the operational characteristics of the autonomous independent sources of electricity we suggest creating the main functional blocks and the elements of the stabilization system in a modular way. The functional circuit solutions of voltage regulators of synchronous generators and the characteristics of their work considered in the article, are able to improve the efficiency of pre-design work in the development of new technical solutions for stabilizing the voltage and the frequency in synchronous generators of electrosupply autonomous systems

  7. Transformerless DC-DC Converter Using Cockcroft-Walton Voltage Multiplier to Obtain High DC Voltage

    Directory of Open Access Journals (Sweden)

    Meghana G Naik,

    2014-11-01

    Full Text Available In the present scenario the use of transformer for high voltages in converter circuit reduces the overall operating efficiency due to leakage inductance and use of transformer also increases the operational cost. . Therefore the proposed system is implemented with transformer less DC-DC converter so as to obtain high DC voltage with the use of nine stage Cockcroft-Walton (CW voltage multiplier. The proposed converter operates in CCM (continuous conduction mode, so that the converter switch stress, the switching losses are reduced. The DC voltage at the input of the proposed model is low and is boosted up by boost inductor (Ls in DC-DC converter stage and performs inverter operation. The number of stages in CW-voltage multiplier circuit is applied with low input pulsating DC (AC Voltage voltage where it is getting converted to high DC output voltage. The proposed converter switches operates at two independent frequencies, modulating (fsm andalternating (fsc frequency. The fsm operates at higher frequency of the output while the fsc operates at lower frequency of the desired output voltage ripple and the output ripples can be adjusted by the switch Sc1 and Sc2. The regulation of the output voltage is achieved by controlling the Duty ratio.The simulation is carried over by the MATLABSIMULINK.

  8. Voltage verification unit

    Science.gov (United States)

    Martin, Edward J.

    2008-01-15

    A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

  9. Oscilaciones de Potencia, Tensión y Corriente en Unidades de Generación Distribuida; Power, Voltage and Current Oscillations in Distributed Generation Units

    Directory of Open Access Journals (Sweden)

    Marcos Alberto de Armas Teyra

    2013-06-01

    Full Text Available En las plantas de generación distribuidas accionadas por motores reciprocantes es necesario conocer las fluctuaciones de tensión, corriente y potencia para evaluar la calidad de la energía que entregan estos grupos electrógenos y como criterio de diagnóstico técnico. Las causas de estas fluctuaciones son diversas. La fundamental se debe a la presencia de oscilaciones forzadas producidas por el momento irregular de los motores primarios. Otras razones se encuentran en las excentricidades constructivas, el desbalance de corriente, los armónicos espaciales y de tiempo, la variación de la configuración del sistema, etc. En este trabajo fueron evaluadas satisfactoriamente las oscilaciones de una máquina conectada a la red mediante la instalación de un analizador de redes de 32 cortes por ciclo a la salida del generador de una de estas unidades. Se expone como caso de estudio las oscilaciones observadas en un generador de 425 kVA480 V accionado por un motor Diesel de seis cilindros y cuatro tiempos en la Provincia de Cienfuegos, Cuba.  In distributed and standby power plants driven by reciprocating motors, is important to know the voltage, current and power oscillation as a delivery power quality and diagnostic criteria. There are several oscillation causes. The fundamental is due to the irregular torque of primary motors. Other causes are due to constructive eccentricities, current unbalance, time and spatial harmonics, changes in systems configuration, etc. In this paper the fundamental oscillations of a grid connected machine were evaluated with a power analyzer installed in one generating power plant. As a case there are shown the observed oscillations in 425 kVA generator driven by a four times, six cylinders Diesel motor in Cienfuegos Province of Cuba.

  10. Oscilaciones de Potencia, Tensión y Corriente en Unidades de Generación Distribuida: Power, Voltage and Current Oscillations in Distributed Generation Units

    Directory of Open Access Journals (Sweden)

    Marcos Alberto de Armas Teyra

    2013-06-01

    Full Text Available En las plantas de generación distribuidas accionadas por motores reciprocantes es necesario conocer las fluctuaciones de tensión, corriente y potencia para evaluar la calidad de la energía que entregan estos grupos electrógenos y como criterio de diagnóstico técnico. Las causas de estas fluctuaciones son diversas. La fundamental se debe a la presencia de oscilaciones forzadas producidas por el momento irregular de los motores primarios. Otras razones se encuentran en las excentricidades constructivas, el desbalance de corriente, los armónicos espaciales y de tiempo, la variación de la configuración del sistema, etc. En este trabajo fueron evaluadas satisfactoriamente las oscilaciones de una máquina conectada a la red mediante la instalación de un analizador de redes de 32 cortes por ciclo a la salida del generador de una de estas unidades. Se expone como caso de estudio las oscilaciones observadas en un generador de 425 kVA480 V accionado por un motor Diesel de seis cilindros y cuatro tiempos en la Provincia de Cienfuegos, Cuba.In distributed and standby power plants driven by reciprocating motors, is important to know the voltage, current and power oscillation as a delivery power quality and diagnostic criteria. There are several oscillation causes. The fundamental is due to the irregular torque of primary motors. Other causes are due to constructive eccentricities, current unbalance, time and spatial harmonics, changes in systems configuration, etc. In this paper the fundamental oscillations of a grid connected machine were evaluated with a power analyzer installed in one generating power plant. As a case there are shown the observed oscillations in 425 kVA generator driven by a four times, six cylinders Diesel motor in Cienfuegos Province of Cuba.

  11. 不对称负载下正序基波有功电流的提取算法%Detecting Method of Positive Sequence Fundamental Active Current under Unbalance Loads

    Institute of Scientific and Technical Information of China (English)

    彭劲杰; 樊晓平

    2013-01-01

    研究正序基波有功电流的正确提取问题,为对电网谐波电流进行快速检测,保证电力系统的安全性,首先利用对称分量方法提取负载电流的正序分量;然后定义两个虚拟电压,利用两个虚拟电压提取正序负载电流的辅助有功分量;将得到的负载电流正序辅助有功分量经过一个低通滤波器,获得负载电流的正序基波辅助有功分量;最后经过一些公式变换提取出负载电流的正序基波有功分量.进行仿真的结果表明,改进算法在系统负载不平衡状态下仍可以准确检测出负载电流中的正序基波有功电流.%A detecting method of positive sequence fundamental active currents was presented.The positive sequence components of the load currents were first extracted by symmetrical component method.Then two invented voltages were defined.The assisting active components of the positive sequence load currents were obtained by two invented voltages.The positive sequence fundamental assisting active components of the load currents were obtained by the positive sequence assisting active components going through a low-pass filter.At last,the positive sequence fundamental active components of the load currents were extracted by some transforming equations.The simulating experiment was carried out using Matlab.The simulating results show that the method can extract the positive sequence fundamental active components from the load currents under unbalance loads.

  12. High Voltage Distribution

    Science.gov (United States)

    Norbeck, Edwin; Miller, Michael; Onel, Yasar

    2010-11-01

    For detector arrays that require 5 to 10 kV at a few microamps each for hundreds of detectors, using hundreds of HV power supplies is unreasonable. Bundles of hundreds of HV cables take up space that should be filled with detectors. A typical HV module can supply 1 ma, enough current for hundreds of detectors. It is better to use a single HV module and distribute the current as needed. We show a circuit that, for each detector, measures the current, cuts off the voltage if the current exceeds a set maximum, and allows the HV to be turned on or off from a control computer. The entire array requires a single HV cable and 2 or 3 control lines. This design provides the same voltage to all of the detectors, the voltage set by the single HV module. Some additional circuitry would allow a computer controlled voltage drop between the HV and each individual detector.

  13. Understanding Voltage Decay in Lithium-Rich Manganese-Based Layered Cathode Materials by Limiting Cutoff Voltage.

    Science.gov (United States)

    Yang, Jingsong; Xiao, Lifen; He, Wei; Fan, Jiangwei; Chen, Zhongxue; Ai, Xinping; Yang, Hanxi; Cao, Yuliang

    2016-07-27

    The effect of the cutoff voltages on the working voltage decay and cyclability of the lithium-rich manganese-based layered cathode (LRMO) was investigated by electrochemical measurements, electrochemical impedance spectroscopy, ex situ X-ray diffraction, transmission electron microscopy, and energy dispersive spectroscopy line scan technologies. It was found that both lower (2.0 V) and upper (4.8 V) cutoff voltages cause severe voltage decay with cycling due to formation of the spinel phase and migration of the transition metals inside the particles. Appropriate cutoff voltage between 2.8 and 4.4 V can effectively inhibit structural variation as the electrode demonstrates 92% capacity retention and indiscernible working voltage decay over 430 cycles. The results also show that phase transformation not only on high charge voltage but also on low discharge voltage should be addressed to obtain highly stable LRMO materials.

  14. High voltage engineering fundamentals

    CERN Document Server

    Kuffel, E; Hammond, P

    1984-01-01

    Provides a comprehensive treatment of high voltage engineering fundamentals at the introductory and intermediate levels. It covers: techniques used for generation and measurement of high direct, alternating and surge voltages for general application in industrial testing and selected special examples found in basic research; analytical and numerical calculation of electrostatic fields in simple practical insulation system; basic ionisation and decay processes in gases and breakdown mechanisms of gaseous, liquid and solid dielectrics; partial discharges and modern discharge detectors; and over

  15. Low-voltage gyrotrons

    Science.gov (United States)

    Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S.; Nusinovich, G. S.

    2013-03-01

    For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5-10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%-2% in the submillimeter wavelength region).

  16. Voltage regulation of connexin channel conductance.

    Science.gov (United States)

    Oh, Seunghoon; Bargiello, Thaddeus A

    2015-01-01

    Voltage is an important parameter that regulates the conductance of both intercellular and plasma membrane channels (undocked hemichannels) formed by the 21 members of the mammalian connexin gene family. Connexin channels display two forms of voltage-dependence, rectification of ionic currents and voltage-dependent gating. Ionic rectification results either from asymmetries in the distribution of fixed charges due to heterotypic pairing of different hemichannels, or by channel block, arising from differences in the concentrations of divalent cations on opposite sides of the junctional plaque. This rectification likely underpins the electrical rectification observed in some electrical synapses. Both intercellular and undocked hemichannels also display two distinct forms of voltage-dependent gating, termed Vj (fast)-gating and loop (slow)-gating. This review summarizes our current understanding of the molecular determinants and mechanisms underlying these conformational changes derived from experimental, molecular-genetic, structural, and computational approaches.

  17. Device for monitoring cell voltage

    Science.gov (United States)

    Doepke, Matthias [Garbsen, DE; Eisermann, Henning [Edermissen, DE

    2012-08-21

    A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

  18. High voltage pulse generator

    Science.gov (United States)

    Fasching, George E.

    1977-03-08

    An improved high-voltage pulse generator has been provided which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of a first one of the rectifiers connected between the first and second of the plurality of charging capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. Alternate circuits are provided for controlling the application of the charging voltage from a charging circuit to be applied to the parallel capacitors which provides a selection of at least two different intervals in which the charging voltage is turned "off" to allow the SCR's connecting the capacitors in series to turn "off" before recharging begins. The high-voltage pulse-generating circuit including the N capacitors and corresponding SCR's which connect the capacitors in series when triggered "on" further includes diodes and series-connected inductors between the parallel-connected charging capacitors which allow sufficiently fast charging of the capacitors for a high pulse repetition rate and yet allow considerable control of the decay time of the high-voltage pulses from the pulse-generating circuit.

  19. Improving Low Voltage Ride Through Capability of Wind Generators Using Dynamic Voltage Restorer

    Science.gov (United States)

    Sivasankar, Gangatharan; Suresh Kumar, Velu

    2014-08-01

    The increasing wind power integration with power grid has forced the situation to improve the reliability of wind generators for stable operation. One important problem with induction generator based wind farm is its low ride through capability to the grid voltage disturbance. Any disturbance such as voltage dip may cause wind farm outages. Since wind power contribution is in predominant percentage, such outages may lead to stability problem. The proposed strategy is to use dynamic voltage controller (DVR) to compensate the voltage disturbance. The DVR provides the wind generator the ability to remain connected in grid and improve the reliability. The voltage dips due to symmetrical and unsymmetrical faults are considered for analysis. The vector control scheme is employed for fault compensation which uses software phase locked loop scheme and park dq0 transformation technique. Extensive simulation results are included to illustrate the control and operation of DVR.

  20. Determination of the aging offset voltage of AMR sensors based on accelerated degradation test

    NARCIS (Netherlands)

    Zambrano, Andreina; Kerkhoff, Hans G.

    2015-01-01

    Usually Anisotropic Magnetoresistance angle sensors are configured with two Wheatstone bridges, but an undesirable offset voltage included in the sensor output affects its accuracy. The total offset voltage combines a voltage due to resistance mismatches during manufacturing and a voltage from inequ

  1. Voltage Regulators for Photovoltaic Systems

    Science.gov (United States)

    Delombard, R.

    1986-01-01

    Two simple circuits developed to provide voltage regulation for highvoltage (i.e., is greater than 75 volts) and low-voltage (i.e., is less than 36 volts) photovoltaic/battery power systems. Use of these circuits results in voltage regulator small, low-cost, and reliable, with very low power dissipation. Simple oscillator circuit controls photovoltaic-array current to regulate system voltage and control battery charging. Circuit senses battery (and system) voltage and adjusts array current to keep battery voltage from exceeding maximum voltage.

  2. Performance of Three-Arm Ac Automatic Voltage Regulator

    Directory of Open Access Journals (Sweden)

    T. Papinaidu

    2014-04-01

    Full Text Available In this paper the design and simulation of automatic voltage regulator (AVR is proposed. The AVR provides voltage buck and boost capability to eliminate power problems created by under voltage or over voltage fluctuations. It also protects against minor and severe spikes and surges that comprise over 80% of power problems. Over heating of components due to voltage swell is also avoided by using AVR. The switching losses are also reduced as only one arm among three arms is maintained at higher power frequencies depending on mode of operation. Moreover, there is no need to use large capacitor as a result the overall size of converter is also reduced. Hence, the output voltage of the AVR can be maintained at the specified voltage. Hence, the AVR is cost can be reduced, and the efficiency of the power convertor can be extended.

  3. Relationships between Harmonic Characteristics and Different Types of Voltage Source

    Directory of Open Access Journals (Sweden)

    Yusniati Yusniati

    2012-06-01

    Full Text Available This paper discusses about harmonic characteristics due to different types of voltage sources. Usually, the voltage source is sinusoidal. But in actual condition the load that receive voltage sources through the elements where the output voltage of element as input to the load is not pure sinusoidal, for example voltage source at  (PCC between transformer and linear load and nonlinear load. This research has been done with Schhafner Power Quality Analyzer and PM300 Power Quality Analyzer, was focused to all harmonic characteristics as power, voltage, current, power factor (p.f., Harmonic Distortion, and harmonic energy losses cost. The load is Induction Motor with Adjustable Speed Drive (ASD because the Induction Motor with Adjustable Speed Drive (ASD is one of electronic device causes harmonics. The voltage sources in this research are sine wave, square wave and harmonic order combinations of 3rd, 5th and 7th which can create from Schhafner Power Quality Analyzer.

  4. Relationships between Harmonic Characteristics and Different Types of Voltage Source

    Directory of Open Access Journals (Sweden)

    Syafruddin H

    2012-06-01

    Full Text Available This paper discusses about harmonic characteristics due to different types of voltage sources. Usually, the voltage source is sinusoidal. But in actual condition the load that receive voltage sources through the elements where the output voltage of element as input to the load is not pure sinusoidal, for example voltage source at  (PCC between transformer and linear load and nonlinear load. This research has been done with Schhafner Power Quality Analyzer and PM300 Power Quality Analyzer, was focused to all harmonic characteristics as power, voltage, current, power factor (p.f., Harmonic Distortion, and harmonic energy losses cost. The load is Induction Motor with Adjustable Speed Drive (ASD because the Induction Motor with Adjustable Speed Drive (ASD is one of electronic device causes harmonics. The voltage sources in this research are sine wave, square wave and harmonic order combinations of 3rd, 5th and 7th which can create from Schhafner Power Quality Analyzer.

  5. Studying Voltage Transformer Ferroresonance

    Directory of Open Access Journals (Sweden)

    Hamid Radmanesh

    2012-09-01

    Full Text Available This study studies the effect of Circuit Breaker Shunt Resistance (CBSR, Metal Oxide Vaistor (MOV and Neutral earth Resistance (NR on the control of ferroresonance in the voltage transformer. It is expected that NR can controlled ferroresonance better than MOV and CBSR. Study has been done on a one phase voltage transformer rated 100 VA, 275 kV. The simulation results reveal that considering the CBSR and MOV exhibits a great mitigating effect on ferroresonance overvoltages, but these resistances cannot control these phenomena for all range of parameters. By applying NR to the system structure, ferroresonance has been controlled and its amplitude has been damped for all parameters values.

  6. Automatic Voltage Control (AVC) System under Uncertainty from Wind Power

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Flynn, Damian

    2016-01-01

    An automatic voltage control (AVC) system maintains the voltage profile of a power system in an acceptable range and minimizes the operational cost by coordinating the regulation of controllable components. Typically, all of the parameters in the optimization problem are assumed to be certain...... and constant in the decision making process. However, for high shares of wind power, uncertainty in the decision process due to wind power variability may result in an infeasible AVC solution. This paper proposes a voltage control approach which considers the voltage uncertainty from wind power productions....... The proposed method improves the performance and the robustness of a scenario based approach by estimating the potential voltage variations due to fluctuating wind power production, and introduces a voltage margin to protect the decision against uncertainty for each scenario. The effectiveness of the proposed...

  7. Cryocooled Josephson standards for AC voltage metrology

    Science.gov (United States)

    Durandetto, P.; Sosso, A.; Monticone, E.; Trinchera, B.; Fretto, M.; Lacquaniti, V.

    2017-05-01

    The Josephson effect is worldwide used as a basis for constant reference voltages in national metrological institutes and in calibration laboratories of industry. Research on Josephson voltage standards is aiming at a fundamental change also in the metrology of the volt for AC and arbitrary waveforms: programmable Josephson voltage standards converting a digital code into a quantum-accurate stepwise waveform are already available in primary laboratories and even more advanced standards for converting sub-nanosecond binary coded pulses into any arbitrary signal with quantum accuracy are now actively developed and tested. A new experimental setup based on a two-stage Gifford-McMahon cryocooler has been developed at INRiM for the operation of AC-Josephson voltage standards. Among its distinct features, the possibility of employing both the aforementioned techniques (programmable and pulsed Josephson voltage standards) is particularly interesting. Quantum-based AC voltage sine waves have been synthesized with both programmable and pulse-driven arrays, although their accuracy is still limited by thermal oscillations due to the cryocooler piston motion.

  8. Large Capacity SMES for Voltage Dip Compensation

    Science.gov (United States)

    Iwatani, Yu; Saito, Fusao; Ito, Toshinobu; Shimada, Mamoru; Ishida, Satoshi; Shimanuki, Yoshio

    Voltage dips of power grids due to thunderbolts, snow damage, and so on, cause serious damage to production lines of precision instruments, for example, semiconductors. In recent years, in order to solve this problem, uninterruptible power supply systems (UPS) are used. UPS, however, has small capacity, so a great number of UPS are needed in large factories. Therefore, we have manufactured the superconducting magnetic energy storage (SMES) system for voltage dip compensation able to protect loads with large capacity collectively. SMES has advantages such as space conservation, long lifetime and others. In field tests, cooperating with CHUBU Electric Power Co., Inc. we proved that SMES is valuable for compensating voltage dips. Since 2007, 10MVA SMES improved from field test machines has been running in a domestic liquid crystal display plant, and in 2008, it protected plant loads from a number of voltage dips. In this paper, we report the action principle and components of the improved SMES for voltage dip compensation, and examples of waveforms when 10MVA SMES compensated voltage dips.

  9. VOLTAGE REGULATORS ASYNCHRONOUS GENERATORS

    Directory of Open Access Journals (Sweden)

    Grigorash O. V.

    2015-06-01

    Full Text Available A promising is currently the use of asynchronous generators with capacitive excitation as a source of electricity in stand-alone power systems. Drive asynchronous generators may exercise as a thermal engine and wind wheel wind power plant or turbines of small hydropower plants. The article discusses the structural and schematics of voltage stabilizers and frequency of asynchronous generators with improved operational and technical specifications. Technical novelty of design solutions of the magnetic system and stabilizers asynchronous generator of electricity parameters confirmed by the patents for the invention of the Russian Federation. The proposed technical solution voltage stabilizer asynchronous generators, can reduce the weight of the block capacitors excitation and reactive power compensation, as well as to simplify the control system power circuit which has less power electronic devices. For wind power plants it is an important issue not only to stabilize the voltage of the generator, but also the frequency of the current. Recommend functionality stabilizer schemes parameters of electric power made for direct frequency converters with artificial and natural switching power electronic devices. It is also proposed as part of stabilization systems use single-phase voltage, three-phase transformers with rotating magnetic field, reduce the level of electromagnetic interference generated by power electronic devices for switching, enhance the efficiency and reliability of the stabilizer.

  10. Geomagnetism and Induced Voltage

    Science.gov (United States)

    Abdul-Razzaq, W.; Biller, R. D.

    2010-01-01

    Introductory physics laboratories have seen an influx of "conceptual integrated science" over time in their classrooms with elements of other sciences such as chemistry, biology, Earth science, and astronomy. We describe a laboratory to introduce this development, as it attracts attention to the voltage induced in the human brain as it…

  11. High-voltage picoamperemeter

    Energy Technology Data Exchange (ETDEWEB)

    Bugl, Andrea; Ball, Markus; Boehmer, Michael; Doerheim, Sverre; Hoenle, Andreas; Konorov, Igor [Technische Universitaet Muenchen, Garching (Germany); Ketzer, Bernhard [Technische Universitaet Muenchen, Garching (Germany); Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany)

    2014-07-01

    Current measurements in the nano- and picoampere region on high voltage are an important tool to understand charge transfer processes in micropattern gas detectors like the Gas Electron Multiplier (GEM). They are currently used to e.g. optimize the field configuration in a multi-GEM stack to be used in the ALICE TPC after the upgrade of the experiment during the 2nd long shutdown of the LHC. Devices which allow measurements down to 1pA at high voltage up to 6 kV have been developed at TU Muenchen. They are based on analog current measurements via the voltage drop over a switchable shunt. A microcontroller collects 128 digital ADC values and calculates their mean and standard deviation. This information is sent with a wireless transmitting unit to a computer and stored in a root file. A nearly unlimited number of devices can be operated simultaneously and read out by a single receiver. The results can also be displayed on a LCD directly at the device. Battery operation and the wireless readout are important to protect the user from any contact to high voltage. The principle of the device is explained, and systematic studies of their properties are shown.

  12. ROTOR UNBALANCE LOAD CONTROL OF WIND TURBINE BASED ON UNIVERSAL MODEL%基于泛模型的风轮不平衡载荷控制

    Institute of Scientific and Technical Information of China (English)

    王晓东; 姚兴佳

    2012-01-01

    针对大型变速变桨风电机组风轮的非线性特征和难以建立精确模型的问题,设计了一种基于泛模型的风轮不平衡载荷自适应控制器.根据传感器测量的叶根载荷,对3个叶片进行独立变桨控制,通过3个叶片的桨距角差异来减小风轮的不平衡载荷.在此基础上,以双馈变速变桨机组为对象,通过仿真对该控制器进行了测试,结果表明该方法用于减小风轮的不平衡载荷是可行且有效的.%With the increasing of wind turbine size and rotor diameter, the wind shear, turbulence and tower shadow more and more affect the load of large scale turbine. Dynamic unbalance load become a key in large scale wind turbine design. It is approved that the pitch control can impact on the rotor loads. Considering the difficulty to build the exact model and non-linear character of rotor, an individual controller banded on universal model was developed in to mitigate the rotor unbalance load for variable speed wind turbine. The controller adjusts the pitch angle of three blades individually based on the measurement load. The pitch angle difference could reduce the effect of wind diversification in the rotor plane. The controller was simulated based on a doubly fed variable speed wind turbine model. The simulation result verified that it is feasible and effective.

  13. Adaptive unbalance compensation control of active magnetic bearing supporting rotor system%主动电磁轴承转子系统自适应不平衡补偿控制

    Institute of Scientific and Technical Information of China (English)

    蒋科坚; 祝长生

    2011-01-01

    为了抑制振动,提高转子旋转精度,提出一种基于振动识别的不平衡补偿控制方法.该方法无需控制对象的传递函数,通过对主动电磁轴承施加试探性补偿信号,同时检测转子位移响应中不平衡振动的幅值和相位变化,直接计算出不平衡振动的Fourier系数,产生精确的补偿电磁力,实现不平衡补偿控制.在控制性能测试的实验中,振动响应的功率谱显示转速频率的振动能量有近30 dB的下降.实验结果表明,该方法对不平衡振动的抑制效果是显著的.%For suppressing vibrations and improving the rotor's rotating precision, a novel unbalance compensation method was proposed, which does not need the transfer function of plant model. The proposed method can directly obtain the Fourier coefficients of unbalance vibration and generate the accurate magnetic force to achieve unbalance compensation by injecting a trial signal into the active magnetic bearing (AMB) and meanwhile measuring the variety in magnitude and phase of the rotor's displacement response.Finally, in an experiment for testing the algorithm's efficiency and precision, approximately 30 dB reduction in unbalance vibrations was obtained in the power spectrum of rotor vibration. The experimental results indicate that the proposed algorithm is effective for suppressing rotor unbalance vibration.

  14. Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal

    KAUST Repository

    Kim, Younggy

    2011-01-01

    Voltages produced by microbial fuel cells (MFCs) cannot be sustainably increased by linking them in series due to voltage reversal, which substantially reduces stack voltages. It was shown here that MFC voltages can be increased with continuous power production using an electronic circuit containing two sets of multiple capacitors that were alternately charged and discharged (every one second). Capacitors were charged in parallel by the MFCs, but linked in series while discharging to the circuit load (resistor). The parallel charging of the capacitors avoided voltage reversal, while discharging the capacitors in series produced up to 2.5 V with four capacitors. There were negligible energy losses in the circuit compared to 20-40% losses typically obtained with MFCs using DC-DC converters to increase voltage. Coulombic efficiencies were 67% when power was generated via four capacitors, compared to only 38% when individual MFCs were operated with a fixed resistance of 250 Ω. The maximum power produced using the capacitors was not adversely affected by variable performance of the MFCs, showing that power generation can be maintained even if individual MFCs perform differently. Longer capacitor charging and discharging cycles of up to 4 min maintained the average power but increased peak power by up to 2.6 times. These results show that capacitors can be used to easily obtain higher voltages from MFCs, allowing for more useful capture of energy from arrays of MFCs. © 2011 The Royal Society of Chemistry.

  15. Deployment of low-voltage regulator considering existing voltage control in medium-voltage distribution systems

    Directory of Open Access Journals (Sweden)

    Hiroshi Kikusato

    2016-01-01

    Full Text Available Many photovoltaic (PV systems have been installed in distribution systems. This installation complicates the maintenance of all voltages within the appropriate range in all low-voltage distribution systems (LVDSs because the trends in voltage fluctuation differ in each LVDS. The installation of a low-voltage regulator (LVR that can accordingly control the voltage in each LVDS has been studied as a solution to this problem. Voltage control in a medium-voltage distribution system must be considered to study the deployment of LVRs. In this study, we installed LVRs in the LVDSs in which the existing voltage-control scheme cannot prevent voltage deviation and performed a numerical simulation by using a distribution system model with PV to evaluate the deployment of the LVRs.

  16. Analyzing of Dynamic Voltage Restorer in Series Compensation Voltage

    Directory of Open Access Journals (Sweden)

    Naser Parhizgar

    2012-02-01

    Full Text Available The Dynamic Voltage Restorer (DVR is a series-connected compensator to generate a controllable voltage to against the short-term voltage disturbances. The technique of DVR is an effective and cost competitive approach to improve voltage quality at the load side. This study presents a single-phase and threephase DVR system with reduced switch-count topology to protect the sensitive load against abnormal voltage conditions. Most basic function, the DVR configuration consist of a two level Voltage Source Converter (VSC, a dc energy storage device, a coupling transformer Connected in shunt with the ac system This study presents the application of Dynamic Voltage Restorer (DVR on power distribution systems for mitigation of voltage sag at critical loads. DVR is one of the compensating types of custom power devices. The DVR, which is based on forced-commutated Voltage Source Converter (VSC has been proved suitable for the task of compensating voltage sags/swells. Simulation results are presented to illustrate and understand the performances of DVR in supporting load voltages under voltage sags/swells conditions.

  17. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  18. Wide Operating Voltage Range Fuel Cell Battery Charger

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Mira Albert, Maria del Carmen; Sen, Gokhan;

    2014-01-01

    DC-DC converters for fuel cell applications require wide voltage range operation due to the unique fuel cell characteristic curve. Primary parallel isolated boost converter (PPIBC) is a boost derived topology for low voltage high current applications reaching an efficiency figure up to 98.2 %. Th...

  19. Wide Operating Voltage Range Fuel Cell Battery Charger

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Mira Albert, Maria del Carmen; Sen, Gokhan

    2014-01-01

    DC-DC converters for fuel cell applications require wide voltage range operation due to the unique fuel cell characteristic curve. Primary parallel isolated boost converter (PPIBC) is a boost derived topology for low voltage high current applications reaching an efficiency figure up to 98.2 %. Th...

  20. Voltage Estimation in Active Distribution Grids Using Neural Networks

    DEFF Research Database (Denmark)

    Pertl, Michael; Heussen, Kai; Gehrke, Oliver;

    2016-01-01

    The power flow in distribution grids is becoming more complicated as reverse power flows and undesired voltage rises might occur under particular circumstances due to integration of renewable energy sources, increasing the occurrence of critical bus voltages. To identify these critical feeders...

  1. Increased voltage photovoltaic cell

    Science.gov (United States)

    Ross, B.; Bickler, D. B.; Gallagher, B. D. (Inventor)

    1985-01-01

    A photovoltaic cell, such as a solar cell, is provided which has a higher output voltage than prior cells. The improved cell includes a substrate of doped silicon, a first layer of silicon disposed on the substrate and having opposite doping, and a second layer of silicon carbide disposed on the first layer. The silicon carbide preferably has the same type of doping as the first layer.

  2. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  3. A random resistor network model of voltage trimming

    Energy Technology Data Exchange (ETDEWEB)

    Grimaldi, C [Laboratoire de Production Microtechnique, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Maeder, T [Laboratoire de Production Microtechnique, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Ryser, P [Laboratoire de Production Microtechnique, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Straessler, S [Laboratoire de Production Microtechnique, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland)

    2004-08-07

    In industrial applications, the controlled adjustment (trimming) of resistive elements via the application of high voltage pulses is a promising technique, with several advantages with respect to more classical approaches such as the laser cutting method. The microscopic processes governing the response to high voltage pulses depend on the nature of the resistor and on the interaction with the local environment. Here we provide a theoretical statistical description of voltage discharge effects on disordered composites by considering random resistor network models with different properties and processes due to the voltage discharge. We compare standard percolation results with biased percolation effects and provide a tentative explanation of the different scenarios observed during trimming processes.

  4. A thermoelectric voltage effect in polyethylene oxide

    CERN Document Server

    Martin, B; Kliem, H

    2003-01-01

    The conductivity of polyethylene oxide (PEO) is described with a three-dimensional hopping model considering electrostatic interactions between the ions. Ions fluctuate over energy-barriers in a multi-well potential. To decide whether positive or negative charges are responsible for this conductivity, the thermoelectric voltage is measured. The samples are embedded between two aluminium-electrodes. The oxide on the interface between the electrodes and the PEO serves as a blocking layer. The temperature of each electrode is controlled by a Peltier element. A temperature step is applied to one electrode by changing the temperature of one of the Peltier elements. Due to this temperature gradient, the mobile charges fluctuate thermally activated from the warmer side to the colder side of the sample. The direction of the measured thermoelectric voltage indicates the type of mobile charges. It is found that positive charges are mobile. Further, it is shown that the absolute value of the thermoelectric voltage depen...

  5. CNFET Based Voltage Differencing Transconductance Amplifier

    Science.gov (United States)

    Laxya; Prasad, Dinesh; Mainuddin; Islam, S. S.

    2017-08-01

    In CMOS Technology basic Problem mainly includes dopant fluctuation, tunnelling effect and line edge roughness below 45nm technology. Carbon Nanotube based structures is better option for widen the Moore’s law due to its scalability channel electrostatics and higher mobility. In this manuscript we demonstrate an optimum design for linear property of CNTFET based VDTA at 32nm technology node. The proposed circuit consist of VDTA with CNTFET having two voltage input and two current outputs so that it works as voltage and transconductance operation to obtain the high performance. The minimum supply voltages of ±0.9V with 32nm technology mode are used. The CNTFET-VDTA performance is simulated on HSPICE. In this paper CNFET-based VDTA provides better results of DC transfer characteristics as compared with CMOS. All the simulation results are performed on HSPICE.

  6. Optical voltage sensors: principle, problem and research proposal

    Science.gov (United States)

    Li, Changsheng

    2016-10-01

    Sensing principles and main problems to be solved for optical voltage sensors are briefly reviewed. Optical effects used for voltage sensing usually include electro-optic Pockels and Kerr effects, electro-gyration effect, elasto-optical effect, and electroluminescent effects, etc. In principle, typical optical voltage sensor is based on electro-optic Pockels crystals and closed-loop signal detection scheme. Main problems to be solved for optical voltage sensors include: how to remove influence of unwanted multiple optical effects on voltage sensing performance; how to select or develop a proper voltage sensing material and element; how to keep optical phase bias to be stable under temperature fluctuation and vibration; how to achieve dc voltage sensing, etc. In order to suppress the influence of unwanted optical effects and light beam coupling-related loss on voltage sensing signals, we may pay more attention to all-fiber and waveguide voltage sensors. Voltage sensors based on electroluminescent effects are also promising in some application fields due to their compact configuration, low cost and potential long-term reliability.

  7. Voltage Controlled Dynamic Demand Response

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    . An adaptive dynamic model has been developed to determine composite voltage dependency of an aggregated load on feeder level. Following the demand dispatch or control signal, optimum voltage setting at the LV substation is determined based on the voltage dependency of the load. Furthermore, a new technique...

  8. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P.; Christenson, Todd R.

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  9. A novel high-voltage device structure with an N+ ring in substrate and the breakdown voltage model

    Institute of Scientific and Technical Information of China (English)

    Li Qi; Zhu Jinluan; Wang Weidong; Yue Hongwei; Jin Liangnian

    2011-01-01

    A novel high-voltage device structure with a floating heavily doped N+ ring embedded in the substrate is reported,which is called FR LDMOS.When the N+ ring is introduced in the device substrate,the electric field peak of the main junction is reduced due to the transfer of the voltage from the main junction to the N+ ring junction,and the vertical breakdown characteristic is improved significantly.Based on the Poisson equation of cylindrical coordinates,a breakdown voltage model is developed.The numerical results indicate that the breakdown voltage of the proposed device is increased by 56% in comparison to conventional LDMOS.

  10. Transient voltage sharing in series-coupled high voltage switches

    Directory of Open Access Journals (Sweden)

    Editorial Office

    1992-07-01

    Full Text Available For switching voltages in excess of the maximum blocking voltage of a switching element (for example, thyristor, MOSFET or bipolar transistor such elements are often coupled in series - and additional circuitry has to be provided to ensure equal voltage sharing. Between each such series element and system ground there is a certain parasitic capacitance that may draw a significant current during high-speed voltage transients. The "open" switch is modelled as a ladder network. Analy­sis reveals an exponential progression in the distribution of the applied voltage across the elements. Overstressing thus oc­curs in some of the elements at levels of the total voltage that are significantly below the design value. This difficulty is overcome by grading the voltage sharing circuitry, coupled in parallel with each element, in a prescribed manner, as set out here.

  11. No-Voltage Meter

    Science.gov (United States)

    1976-02-01

    VW- IKft, 1/4 H4 -Wv- IK!1, I/4W INTERNAL VOLTAGE NOTE ALL TRANSISTORS ARE 2N43A OR EQUIVALENT GERMANIUM ALLOY PNP AA ALKALINE BATTERY...D-,, regardless of polarity. This signal is then full-wave rectified by the diode-connected Germanium transistor bridge, T,, T-,, T3, and T4... Transistor T5 acts as a second current limiter. Resistor R2 was selected to give 90 f# of full-scale meter deflection with an input signal of 115 volts

  12. Benchmarking of Voltage Sag Generators

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    The increased penetration of renewable energy systems, like photovoltaic and wind power systems, rises the concern about the power quality and stability of the utility grid. Some regulations for Low Voltage Ride-Through (LVRT) for medium voltage or high voltage applications, are coming into force...... to guide these grid-connected distributed power generation systems. In order to verify the response of such systems for voltage disturbance, mainly for evaluation of voltage sags/dips, a Voltage Sag Generator (VSG) is needed. This paper evaluates such sag test devices according to IEC 61000 in order...... to provide cheaper solutions to test against voltage sags. Simulation and experimental results demonstrate that the shunt impedance based VSG solution is the easiest and cheapest one for laboratory test applications. The back-to-back fully controlled converter based VSG is the most flexible solution...

  13. Three dimensional voltage map scar-related ventricular tachycardias due to myocardial infarction under sinus rhythm%窦性心律下通过三维电压标测心肌梗死后瘢痕性室性心动过速

    Institute of Scientific and Technical Information of China (English)

    贾玉和; 任岚; 方丕华; 唐闽; 毛克修; 赵允梓; 楚建民; 张澍

    2012-01-01

    目的 介绍一种不需行拖带标测,而在窦性心律下可标测和消融心肌梗死后瘢痕性室性心动过速(室速)的方法.方法 两例男性患者,均在心肌梗死和冠状动脉再通治疗后出现室速.经胺碘酮治疗后出现甲状腺功能异常而停药.其中例1为前壁心肌梗死合并心尖部室壁瘤,在发作室速时心功能恶化伴顽固咳嗽;例2为下后壁心肌梗死,其临床室速有两种形态,室性早搏(室早)有多种形态.该两种情况占心肌梗死后室速的大部分,均不太适合常规的拖带标测.首先在窦性心律时在Carto系统指导下建立左心室的三维电解剖图,通过调整瘢痕区电压标准,使梗死边缘区三层结构清楚显示后,沿边缘区行起搏标测,通过特征电位和测量刺激至QRS间距来判定峡部区,然后以峡部区为中心,以垂直于边缘区的方向行连续线性消融,直至室速不能被诱发视为消融终点.结果 两例在消融前均可反复诱发室速,在经过几条垂直线消融后室速均不能被诱发,随访3个月室速也未复发.心功能和生活质量明显改善.但例1出现室壁瘤附壁血栓.结论 对大多数心肌梗死后瘢痕性室速患者,均可在窦性心律下标测到其关键峡部区,并以此为中心点沿着垂直于边缘区方向行线性消融,以室速不能被诱发做为急性期终点同样能得到较好的远期成功率,但术后1个月需保持华法林抗凝.%Objective To introduce an initial experience of mapping scar-related ventricular tachycardias (VTs)after myocardial infarction using three dimensional voltage mapping under sinus rhythm without induction of ventricular tachycardia.Methods Two males with ventricular tachycardias ( VTs ) due to myocardial infarction received percutaneous catheter intervention(PCI) and stent implantation.Both of them had abnormal thyroid function due to amiodarone administration and finally quitted it.Case one with remote anterior wall

  14. Coordinated Voltage Control of Distributed PV Inverters for Voltage Regulation in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    This paper reviews and analyzes the existing voltage control methods of distributed solar PV inverters to improve the voltage regulation and thereby the hosting capacity of a low-voltage distribution network. A novel coordinated voltage control method is proposed based on voltage sensitivity...... analysis, which is simple for computation and requires moderate automation and communication infrastructure. The proposed method is suitable for a hierarchical control structure where a supervisory controller has the provision to adapt the settings of local PV inverter controllers for overall system...

  15. Heat-pump performance: voltage dip/sag, under-voltage and over-voltage

    Directory of Open Access Journals (Sweden)

    William J.B. Heffernan

    2014-12-01

    Full Text Available Reverse cycle air-source heat-pumps are an increasingly significant load in New Zealand and in many other countries. This has raised concern over the impact wide-spread use of heat-pumps may have on the grid. The characteristics of the loads connected to the power system are changing because of heat-pumps. Their performance during under-voltage events such as voltage dips has the potential to compound the event and possibly cause voltage collapse. In this study, results from testing six heat-pumps are presented to assess their performance at various voltages and hence their impact on voltage stability.

  16. Loading Analysis of Modular Multi-level Converter for Offshore High-voltage DC Application under Various Grid Faults

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang;

    2016-01-01

    The modular multi-level converter has become an interesting candidate in high-voltage DC systems due to its higher voltage levels and modular construction. Low-voltage ride-through is an important grid requirement for modular multi-level converter–high-voltage DC since not only causes control cha...... be of importance for the design of the cooling system....

  17. Isomerically Pure Tetramethylrhodamine Voltage Reporters.

    Science.gov (United States)

    Deal, Parker E; Kulkarni, Rishikesh U; Al-Abdullatif, Sarah H; Miller, Evan W

    2016-07-27

    We present the design, synthesis, and application of a new family of fluorescent voltage indicators based on isomerically pure tetramethylrhodamines. These new Rhodamine Voltage Reporters, or RhoVRs, use photoinduced electron transfer (PeT) as a trigger for voltage sensing, display excitation and emission profiles in the green to orange region of the visible spectrum, demonstrate high sensitivity to membrane potential changes (up to 47% ΔF/F per 100 mV), and employ a tertiary amide derived from sarcosine, which aids in membrane localization and simultaneously simplifies the synthetic route to the voltage sensors. The most sensitive of the RhoVR dyes, RhoVR 1, features a methoxy-substituted diethylaniline donor and phenylenevinylene molecular wire at the 5'-position of the rhodamine aryl ring, exhibits the highest voltage sensitivity to date for red-shifted PeT-based voltage sensors, and is compatible with simultaneous imaging alongside green fluorescent protein-based indicators. The discoveries that sarcosine-based tertiary amides in the context of molecular-wire voltage indicators prevent dye internalization and 5'-substituted voltage indicators exhibit improved voltage sensitivity should be broadly applicable to other types of PeT-based voltage-sensitive fluorophores.

  18. Four-Switch Three-Phase PMSM Converter with Output Voltage Balance and DC-Link Voltage Offset Suppression

    Directory of Open Access Journals (Sweden)

    Fadil Hicham

    2017-01-01

    Full Text Available High power quality, efficiency, complexity, size, cost effectiveness and switching losses of the direct current to alternating current (DC–AC conversion system are crucial aspects in industrial applications. Therefore, the four-switch three-phase inverter (4S3P has been proposed as an innovative inverter design. However, this topology has been known to have many performance limitations in the low-frequency region, because of the generation of an unbalanced voltage leading to an unbalanced current due to the fluctuation and offset of the centre tap voltage of the DC-link capacitors. Those drawbacks are investigated and solved in this paper in order to provide pure sinusoidal output voltages. The generated output voltages are controlled using proportional-integral (PI controllers to follow the desired voltages. Furthermore, the DC-link capacitor voltage offset is mitigated by subtracting the direct component from the control reference voltage using low pass filters, where this direct voltage component provides the direct current component which leads to DC-link capacitor voltage divergence. A simulation model and experimental setup are used to validate the proposed concept. Many simulation and experimental results are carried out to show the effectiveness of the proposed control scheme.

  19. Living and Working Safely Around High-Voltage Power Lines.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    2001-06-01

    High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

  20. 基于不平衡同频激励的密封动力特性系数识别%Experimental Identification Method Using Unbalance Synchronous Frequency Excitation for Seals Rotordynamic Coefficients Analysis

    Institute of Scientific and Technical Information of China (English)

    曹浩; 杨建刚; 张万福; 郭瑞

    2011-01-01

    Considering the disadvantage of traditional frequency-domain identification method for rotordynamic coefficients of seals, a method of synchronous frequency excitation using rotor unbalance was proposed. 4 independent equations were built under 2 sets of rotor unbalance conditions. Influences of rotor unbalance, rotating speed, inlet/outlet pressure ratio on dynamic coefficients was tested. Results show that the direct rotordynamic coefficients are nearly equal and with same sign in the directions of vertical and horizontal. The cross-coupled items are nearly equal but with opposite sign. 8 rotordynamic coefficients all increase with increasing of inlet/outlet pressure ratio and rotating speed. The direct stiffness coefficients increase more quickly than the cross-coupled. The increasing trend of direct and cross-coupled damping coefficients is almost same. We also find the dynamic coefficients are little affected by different rotor unbalances. Finally, the paper analyzes the influence factors for the identification accuracy, and proposes the choose method for range of rotating speed and rotor unbalance conditions.%针对传统频域识别密封动力特性系数方法存在的问题,提出利用转子不平衡实现同频激励,在2组不平衡状态下构建4个独立方程,建立密封动力特性系数识别模型。在密封试验台上研究了转子不平衡、转速、进出口压比等因素对密封动力特性系数的影响。试验结果表明动力特性系数中直接项系数相近,交叉项大小相同,符号相反。随着进出口压比和转速的增大,8个密封动力特性系数都增大,直接刚度项增大幅度较交叉刚度项更为明显,直接阻尼项增大幅度与交叉阻尼项接近。同时发现相对振动大小对动力特性系数影响并不大。对影响动力特性系数识别精度的因素进行了分析,提出了试验转速、不平衡工况的合理选择方法。

  1. Impacts on Power Factor of AC Voltage Controllers Under Non-Sinusoidal Conditions

    Directory of Open Access Journals (Sweden)

    Mukhtiar Ahmed Mahar

    2012-04-01

    Full Text Available AC-AC conversion is obtained with the help of Cyclo-converters, DC Link converters and AC Voltage Controllers. AC voltage controllers are also referred to as voltage regulators. Main issue concerned to these converters is that they generate harmonics due to periodic variable structure system. The generated harmonics create disturbances and degrade the performance of converter. The power factor of supply side is affected due to these harmonics. This paper focuses on source side power factor of ac voltage controllers under nonsinusoidal conditions. In order to observe the power factor, measurement tool of power factor and simulation model of ac voltage controller is also developed in MATLAB software.

  2. Output voltage calculations in double barrier magnetic tunnel junctions with asymmetric voltage behavior

    KAUST Repository

    Useinov, Arthur

    2011-10-22

    In this paper we study the asymmetric voltage behavior (AVB) of the tunnel magnetoresistance (TMR) for single and double barrier magnetic tunnel junctions (MTJs) in range of a quasi-classical free electron model. Numerical calculations of the TMR-V curves, output voltages and I-V characteristics for negative and positive values of applied voltages were carried out using MTJs with CoFeB/MgO interfaces as an example. Asymmetry of the experimental TMR-V curves is explained by different values of the minority and majority Fermi wave vectors for the left and right sides of the tunnel barrier, which arises due to different annealing regimes. Electron tunneling in DMTJs was simulated in two ways: (i) Coherent tunneling, where the DMTJ is modeled as one tunnel system and (ii) consecutive tunneling, where the DMTJ is modeled by two single barrier junctions connected in series. © 2012 Elsevier B.V. All rights reserved.

  3. Moderately nonlinear diffuse-charge dynamics under an ac voltage

    Science.gov (United States)

    Stout, Robert F.; Khair, Aditya S.

    2015-09-01

    The response of a symmetric binary electrolyte between two parallel, blocking electrodes to a moderate amplitude ac voltage is quantified. The diffuse charge dynamics are modeled via the Poisson-Nernst-Planck equations for a dilute solution of point-like ions. The solution to these equations is expressed as a Fourier series with a voltage perturbation expansion for arbitrary Debye layer thickness and ac frequency. Here, the perturbation expansion in voltage proceeds in powers of Vo/(kBT /e ) , where Vo is the amplitude of the driving voltage and kBT /e is the thermal voltage with kB as Boltzmann's constant, T as the temperature, and e as the fundamental charge. We show that the response of the electrolyte remains essentially linear in voltage amplitude at frequencies greater than the RC frequency of Debye layer charging, D /λDL , where D is the ion diffusivity, λD is the Debye layer thickness, and L is half the cell width. In contrast, nonlinear response is predicted at frequencies below the RC frequency. We find that the ion densities exhibit symmetric deviations from the (uniform) equilibrium density at even orders of the voltage amplitude. This leads to the voltage dependence of the current in the external circuit arising from the odd orders of voltage. For instance, the first nonlinear contribution to the current is O (Vo3) which contains the expected third harmonic but also a component oscillating at the applied frequency. We use this to compute a generalized impedance for moderate voltages, the first nonlinear contribution to which is quadratic in Vo. This contribution predicts a decrease in the imaginary part of the impedance at low frequency, which is due to the increase in Debye layer capacitance with increasing Vo. In contrast, the real part of the impedance increases at low frequency, due to adsorption of neutral salt from the bulk to the Debye layer.

  4. High Output Voltage Based Multiphase Step-Up DC-DC Converter Topology with Voltage Doubler Rectifiers

    Directory of Open Access Journals (Sweden)

    Liao Xiaozhong

    2013-02-01

    Full Text Available High Output Voltage Based Multiphase Step-Up DC-DC Converter topology with voltage doubler rectifiers is presented in this paper. High output voltage is obtained due to the series combination of voltage doubler rectifiers on the secondary side of high frequency transformers. This topology is useful in the application where the output voltage is greater than the input. The two loop control strategy has been developed in order to analyze the stable and effective working of the converter topology. Therefore the working mode analysis of the converter topology has been described in detail. The multiphase step-up DC-DC converter topology is first simulated on MATLAB and then a prototype has been designed in order to verify the simulation and experimental results. Finally the simulation and experimental results are found to be satisfactory.

  5. A study on threshold voltage stability of low operating voltage organic thin-film transistors

    Science.gov (United States)

    Padma, N.; Sen, Shaswati; Sawant, Shilpa N.; Tokas, R.

    2013-08-01

    A low operating voltage (<2 V) organic field-effect transistor (OFET) using phenylhexyltrichlorosilane (PTS) self-assembled monolayer (SAM) dielectric and copper phthalocyanine (CuPc) as semiconductor with improved mobility (0.035 cm2 V-1 s-1) and threshold voltage stability was demonstrated. This device showed better performance when compared to an OFET with octyltrichlorosilane (OTS-8) SAM dielectric. The improved mobility was attributed to the 2D growth mode of CuPc on PTS SAM because of surface energy matching between the two, whereas CuPc film on OTS-8 showed a 3D growth mode with larger grain boundary density. The higher threshold voltage stability of OFETs on PTS SAM was attributed to the efficient coverage and screening of trap centres at dielectric/semiconductor interface due to stronger intermolecular linking and formation of closely packed surface by the bulky phenyl end groups. Decrease in grain boundaries offered by 2D growth of CuPc for electron and hole trapping was also found to be another reason for improved threshold voltage stability. The results indicated that the nature of the end group of SAM dielectric, surface chemistry of dielectric and initial growth mode of semiconductors are all responsible for improvement in threshold voltage stability and enhanced performance of OFET.

  6. Low voltage lightning arresters. Components. Low voltage grids; Parafoudres basse tension. Composants. Reseaux basse tension

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, A. [Assistance Protection System SAS, 94 - Cachan (France)

    2003-08-01

    Electrical equipments used in domestic and industrial applications are more and more sensible to overvoltages because of the massive use of electronic components in these equipments and appliances. Overvoltages do not propagate only with power lines but also through phone lines, coaxial cables, data networks, and even through grounding circuits. The informations about low voltage grids, useful for the selection of lightning arresters are presented in this article. In the ideal case, each possible way of input for overvoltage currents must be protected. The components used in lightning arresters have improved for a better reliability, a better energy resistance and a better protection level. These components are also presented in this article: 1 - technical and standard evolution: improvement of the understanding of low voltage phenomena, standards evolution, recall of basic definitions and data about lightning protection; 2 - components: varistors, spark gaps, silicon-based solid components, aging and end of life, decoupling components (thermistors, resistors, inductors); 3 - low voltage grids: different types of energy networks, transmission of overvoltages on low voltage networks (overvoltages due to lightning, or power station actuating, temporary overvoltages), influence of lightning conductors and lightning strikes close to the building structure, statistical data about lightning overvoltages on low voltage grids, protection and risk analysis. (J.S.)

  7. Voltage-induced reduction of graphene oxide

    Science.gov (United States)

    Faucett, Austin C.

    Graphene Oxide (GO) is being widely researched as a precursor for the mass production of graphene, and as a versatile material in its own right for flexible electronics, chemical sensors, and energy harvesting applications. Reduction of GO, an electrically insulating material, into reduced graphene oxide (rGO) restores electrical conductivity via removal of oxygen-containing functional groups. Here, a reduction method using an applied electrical bias, known as voltage-induced reduction, is explored. Voltage-induced reduction can be performed under ambient conditions and avoids the use of hazardous chemicals or high temperatures common with standard methods, but little is known about the reduction mechanisms and the quality of rGO produced with this method. This work performs extensive structural and electrical characterization of voltage-reduced GO (V-rGO) and shows that it is competitive with standard methods. Beyond its potential use as a facile and eco-friendly processing approach, V-rGO reduction also offers record high-resolution patterning capabilities. In this work, the spatial resolution limits of voltage-induced reduction, performed using a conductive atomic force microscope probe, are explored. It is shown that arbitrary V-rGO conductive features can be patterned into insulating GO with nanoscale resolution. The localization of voltage-induced reduction to length scales < 10 nm allows studies of reduction reaction kinetics, using electrical current obtained in-situ, with statistical robustness. Methods for patterning V-rGO nanoribbons are then developed. After presenting sub-10nm patterning of V-rGO nanoribbons in GO single sheets and films, the performance of V-rGO nanoribbon field effect transistors (FETs) are demonstrated. Preliminary measurements show an increase in electrical current on/off ratios as compared to large-area rGO FETs, indicating transport gap modulation that is possibly due to quantum confinement effects.

  8. Local Dynamic Reactive Power for Correction of System Voltage Problems

    Energy Technology Data Exchange (ETDEWEB)

    Kueck, John D [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Xu, Yan [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Adhikari, Sarina [ORNL; Irminger, Philip [ORNL

    2008-12-01

    Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results

  9. Electronic Voltage and Current Transformers Testing Device

    Directory of Open Access Journals (Sweden)

    Yong Xiao

    2012-01-01

    Full Text Available A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz. The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware.

  10. Methanol unbalance of supply and demand situation will still continue%甲醇供需失衡局面仍将持续

    Institute of Scientific and Technical Information of China (English)

    王向前; 钱惠斌; 胡雪瑛; 袁本成; 王飞虎

    2012-01-01

    甲醇作为重要的化学工业基础原料和清洁液体燃料,被广泛应用于有机合成、医药、农药、涂料、染料等领域,主要用来生产甲醛、醋酸、MTBE、对苯二甲酸二甲酯、丙烯酸甲酯等产品以及醇醚燃料.随着甲醇制烯烃和甲醇燃料等新兴领域的不断开发,虽然为甲醇行业开拓了更为广阔的应用前景,但由于我国甲醇产能无序过快增长、大量进口产品的冲击、下游需求疲软以及投资新建装置热度不减等因素的影响,造成我国甲醇严重供过于求,我国甲醇供需失衡的局面仍将持续.%Methanol as an important chemical industry basis of raw materials and clean liquid fuel, is widely used in organic synthesis,pharmaceutical, pesticide,paint, dye and other fields,mainly used in the production of formaldehyde, acetic acid, MTBE, terephthalic acid methyl methacrylate, products and the alcohol or ether fuel. This paper mainly discusses the methanol to olefins and methanol fuel and other new product development,although for methanol industry to develop a more broad application prospects,but because our country methanol production capacity of disordered growth,many entrance product impact,weak demand and new plant investment heat and other factors,China methanol unbalance of supply and demand situation will still continue.

  11. DETERIORO GENÓMICO Y MANIPULACIÓN GENÉTICA: DESEQUILIBRIO EN LA PRIORIDAD DE LAS AGENDAS PÚBLICAS DETERIORIZAÇÃO GENÔMICA E MANIPULAÇÃO GENÉTICA: DESEQUILÍBRIO NA PRIORIDADE DAS AGENDAS PÚBLICAS GENOME DAMAGE AND GENETIC MANIPULATION: UNBALANCE IN PUBLIC POLICIES PRIORITY

    Directory of Open Access Journals (Sweden)

    Elio A Prieto González

    2007-11-01

    Full Text Available Se analiza el desequilibrio en el tratamiento de dos temas que atañen a la conservación de la integridad del genoma humano: las tecnologías de manipulación genética y el deterioro genómico provocado por la contaminación ambiental. Las carencias educativas, la falta de información asentada en los hechos y un manejo sensacionalista en los medios, entre otros factores, desajustan las agendas mediáticas con las necesidades públicas, lo que desemboca en una falta de conciencia ciudadana acerca de las verdaderas amenazas a las que está expuesto el material genético y los riesgos de salud que ello implicaO presente texto analisa o desequilíbrio no tratamento de dois temas que dizem respeito à conservação da integridade do genoma humano: as tecnologias de manipulação genética e a deteriorização genômica provocada pela contaminação ambiental. As carências educativas, a falta de informação assentada nos fatos e um manejo sensacionalista dos meios, entre outros fatores, desajustam as agendas mediáticas com as necessidades públicas, o que desemboca numa falta de consciência cidadã em relação às verdadeiras ameaças à que se expôs o material genético e os riscos de saúde que isto implicaUnbalance in the treatment of two topics related to the conservation of the human genome integrity is analyzed here: the technologies for genetic manipulation and genome damage due to environmental pollution. Lack of education and of information based on real facts, and the media sensationalist treatment, among other factors, provoke an unbalance between the media agenda and public needs. This leads to a lack of citizenship consciousness over the true threats that genetic material faces and the health risks that it involves

  12. Modelo de Transformador de Distribución Trifásico para Estudios de Máximos de Tensión (Peaks Ocasionados por Descargas Atmosféricas Model of a Three-Phase Transformer for Studies of Voltage Surges (Peaks due to Lighting Discharges

    Directory of Open Access Journals (Sweden)

    A.G Kanashiro

    2004-01-01

    Full Text Available Este trabajo se presenta una metodología para modelar transformadores de distribución trifásico para el estudio de los máximos (peaks de tensión transferidos al secundario, en el caso de descargas atmosféricas directas o indirectas. La validación del modelo fue realizada a través de comparaciones entre simulaciones computacionales y resultados de ensayos obtenidos en el laboratorio. Los resultados mostraron que las tensiones transferidas presentadas por el modelo y por el transformador son mucho más próximas cuando se consideran los impulsos de tensión con formas de onda normalizada (1.2/40m s y típicas de tensiones inducidas. El modelo es simple y representa razonablemente bien el transformador, permitiendo el análisis de las tensiones transferidas en las redes secundarias.This paper presents a methodology for modeling three-phase distribution transformers for the analysis of the voltage surges transferred to the secondary networks when direct or indirect lightning discharges occur. The validation of the model was reached through comparisons between computer simulations and results of tests performed in the laboratory. The results showed that the voltages transferred presented by the model and by the transformer are quite similar when the voltage impulses with both standard (1.2/50m s and typical waveforms of induced voltages are considered. The model is simple and represents the transformer reasonably well, permitting the analysis of the voltages transferred in the secondary networks.

  13. Low Voltage Power Supply Incorporating Ceramic Transformer

    CERN Document Server

    Imori, M

    2007-01-01

    A low voltage power supply provides the regulated output voltage of 1 V from the supply voltage around 48 V. The low voltage power supply incorporates a ceramic transformer which utilizes piezoelectric effect to convert voltage. The ceramic transformer isolates the secondary from the primary, thus providing the ground isolation between the supply and the output voltages. The ceramic transformer takes the place of the conventional magnetic transformer. The ceramic transformer is constructed from a ceramic bar and does not include any magnetic material. So the low voltage power supply can operate under a magnetic field. The output voltage is stabilized by feedback. A feedback loop consists of an error amplifier, a voltage controlled oscillator and a driver circuit. The amplitude ratio of the transformer has dependence on the frequency, which is utilized to stabilize the output voltage. The low voltage power supply is investigated on the analogy of the high voltage power supply similarly incorporating the cerami...

  14. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  15. Reliability criteria for voltage stability

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Carson W.; Silverstein, Brian L. [Bonneville Power Administration, Portland, OR (United States)

    1994-12-31

    In face of costs pressures, there is need to allocate scare resources more effectively in order to achieve voltage stability. This naturally leads to development of probabilistic criteria and notions of rick management. In this paper it is presented a discussion about criteria for long term voltage stability limited to the case in which the time frames are topically several minutes. (author) 14 refs., 1 fig.

  16. A Voltage Quality Detection Method

    DEFF Research Database (Denmark)

    Chen, Zhe; Wei, Mu

    2008-01-01

    This paper presents a voltage quality detection method based on a phase-locked loop (PLL) technique. The technique can detect the voltage magnitude and phase angle of each individual phase under both normal and fault power system conditions. The proposed method has the potential to evaluate vario...... power quality disturbances, such as interruptions, sags and imbalances. Simulation studies have been performed. The effectiveness of the proposed method has been demonstrated under the simulated typical power disturbances....

  17. A matter of quantum voltages.

    Science.gov (United States)

    Sellner, Bernhard; Kathmann, Shawn M

    2014-11-14

    Voltages inside matter are relevant to crystallization, materials science, biology, catalysis, and aqueous chemistry. The variation of voltages in matter can be measured by experiment, however, modern supercomputers allow the calculation of accurate quantum voltages with spatial resolutions of bulk systems well beyond what can currently be measured provided a sufficient level of theory is employed. Of particular interest is the Mean Inner Potential (V(o))--the spatial average of these quantum voltages referenced to the vacuum. Here we establish a protocol to reliably evaluate V(o) from quantum calculations. Voltages are very sensitive to the distribution of electrons and provide metrics to understand interactions in condensed phases. In the present study, we find excellent agreement with measurements of V(o) for vitrified water and salt crystals and demonstrate the impact of covalent and ionic bonding as well as intermolecular/atomic interactions. Certain aspects in this regard are highlighted making use of simple model systems/approximations. Furthermore, we predict V(o) as well as the fluctuations of these voltages in aqueous NaCl electrolytes and characterize the changes in their behavior as the resolution increases below the size of atoms.

  18. A Review on Power System Voltage Stability and Optimization Techniques

    Directory of Open Access Journals (Sweden)

    T. Madhuranthaka

    2016-11-01

    Full Text Available Power system voltage stability is a one of the major focused areas in recent days due to mismatch between generation and demand. Maintenance of voltage stability is a challenging issue in planning and security assessment of power systems. Voltage stability is the ability of a power system to maintain steady acceptable voltages at all buses in the power system under normal operating conditions and after being subjected to a disturbance. Long-term voltage instability problems can occur in heavily loaded systems where the electrical distance is large between the generator and the load. Timely application of reactive power compensation or load shedding may prevent this type of voltage instability. System reactive power handling capacity can be improved with Flexible AC Transmission System (FACTS devices. Identification of critical system locations to undertake appropriate remedial measures in operation is the concern. This paper reviews the performance of various types FACTS controllers in power system voltage stability problem and focuses on different optimization methods implemented for optimal placement and sizing of FACTS devices to minimize power losses.

  19. VOLTAGE COMPENSATION USING ARTIFICIAL NEURAL NETWORK

    African Journals Online (AJOL)

    VOLTAGE COMPENSATION USING ARTIFICIAL NEURAL NETWORK: A CASE STUDY OF RUMUOLA DISTRIBUTION NETWORK. ... The artificial neural networks controller engaged to controlling the dynamic voltage ... Article Metrics.

  20. H∞ Robust Current Control for DFIG Based Wind Turbine subject to Grid Voltage Distortions

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Gong, Wenming

    2016-01-01

    distortions considered include asymmetric voltage dips and grid background harmonics. An uncertain DFIG model is developed with uncertain factors originating from distorted stator voltage, and changed generator parameters due to the flux saturation effect, the skin effect, etc. Weighting functions......This paper proposes an H∞ robust current controller for doubly fed induction generator (DFIG) based wind turbines (WTs) subject to grid voltage distortions. The controller is to mitigate the impact of the grid voltage distortions on rotor currents with DFIG parameter perturbation. The grid voltage...

  1. Combating the Reliability Challenge of GPU Register File at Low Supply Voltage

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Jingweijia; Song, Shuaiwen; Yan, Kaige; Fu, Xin; Marquez, Andres; Kerbyson, Darren J.

    2016-09-11

    Supply voltage reduction is an effective approach to significantly reduce GPU energy consumption. As the largest on-chip storage structure, the GPU register file becomes the reliability hotspot that prevents further supply voltage reduction below the safe limit (Vmin) due to process variation effects. This work addresses the reliability challenge of the GPU register file at low supply voltages, which is an essential first step for aggressive supply voltage reduction of the entire GPU chip. We propose GR-Guard, an architectural solution that leverages long register dead time to enable reliable operations from unreliable register file at low voltages.

  2. 基于谐波小波和Prony算法的转子不平衡信号提取%Extraction of rotor unbalance signal based on harmonic wavelet and Prony algorithm

    Institute of Scientific and Technical Information of China (English)

    李传江; 费敏锐; 胡豁生; 张自强; 邓丽

    2012-01-01

    In high-precision dynamic balance measurement system, signal-to-noise ratio is very low. Conventional methods, such as fast Fourier transformation(FFT) , can not extract unbalance signal accurately. An unbalance signal extraction method based on harmonic wavelet and Prony algorithm is proposed. Firstly, adaptive harmonic wavelet band-pass filter is used to improve signal-to-noise ratio. And then with the filtered data as sample, Prony method is adopted to identify the amplitude and phase of the unbalance signal, which effectively solves the problem of unable to accurately extract the unbalance signal induced by adjacent frequency interference. Simulation and experiment results show that the proposed method has the advantages of high precision and good repeatability, and is specially suitable for high-precision dynamic balance measurement system with low signal to noise ratio.%高精度动平衡测量系统中的信噪比很低,尤其是在邻近频率干扰背景下,常规的快速博里叶变换(fast Fourier trasformation,FFT)等方法无法准确提取不平衡信号.提出一种基于谐波小波和Prony算法的不平衡信号提取方法,先采用自适应谐波小波带通滤波提高信噪比,然后以滤波后的数据作为样本,采用Prony算法识别不平衡信号的幅值和相位,有效解决了邻近频率干扰导致的不平衡信号无法准确提取的问题.仿真和实验结果表明,该方法具有精度高、重复性好等优点,特别适合于信噪比较低的高精度动平衡测量系统中.

  3. Kirchhoff voltage law corrected for radiating circuits

    CERN Document Server

    Lara, Vitor

    2014-01-01

    When a circular loop composed by a RLC is put to oscillate, the oscillation will eventually vanish in an exponentially decaying current, even considering superconducting wires, due to the emission of electric and magnetic dipole radiation. In this work we propose a modification on the Kirchhoff voltage law by adding the radiative contributions to the energy loss as an effective resistance, whose value is relatively small when compared to typical resistance value, but fundamental to describe correctly real circuits. We have also analysed the change in the pattern of the radiation spectra emitted by the circuit as we vary both the effective and electrical resistance.

  4. Fault ride-through capability of wind turbine connected to the grid in case of unbalanced voltages

    Directory of Open Access Journals (Sweden)

    Ivanović Zoran R.

    2016-01-01

    Full Text Available This paper deals with control of wind turbine connected to the grid through the back-to-back converter in case of unbalanced grid voltages. The motivation for this research has been found in recent transmission and distribution grid code, which demand modern wind turbines to stay connected to the grid and supply the highest possible apparent power during the grid disturbances. In order to comply with these requirements we proposed improved dual vector current controller to deal with the unbalance imposed by the electrical grid. Controller provides injection of active and reactive power to the grid, even if the voltages are lower than the nominal one. The results are validated using low power prototype and contemporary hardware-in-the-loop emulation platform. In both cases the controller is based on TMS320F2812 DSP. [Projekat Ministarstva nauke Republike Srbije, br. III 042004 and by the Provincial Secretariat for Science and Technological Development of AP Vojvodina under contract No. 114-451-3508/2013-04

  5. Harmonics Phase Shifter for a Three-Phase System with Voltage Control by Integral-Cycle Triggering Mode of Thyristors

    Directory of Open Access Journals (Sweden)

    I. Badran

    2008-01-01

    Full Text Available n integral-cycle triggering mode of voltage control, subharmonic as well as higher order harmonic components are generated in the load voltage waveforms of a three-phase system. These harmonic components are found to be unbalanced in phase displacement. The correction of the unbalanced phase displacement angles of a particular subharmonic or higher order harmonic for this type of triggering is investigated to solve the limitation of use of this important type of control as a drive and many other industrial applications. In this research a new phase shifting technique is proposed to correct the unbalanced phase displacement angles in the three-phase system. This technique depends on shifting the waveforms of either phase B or phase C or both by multiples of 2π. A microprocessor-based harmonic phase shifter is designed and tested with three-phase resistive and induction motor loads. It is found that there is a well agreement between the theoretical and experimental results and it is believed that the major problem of harmonics phase unbalances associated with the integral-cycle triggering mode of thyristors when used with three-phase circuits have been solved in the present research.

  6. Zero-voltage switching technique in dc/dc converters

    Science.gov (United States)

    Liu, Kwang-Hwa; Lee, Fred C. Y.

    1990-07-01

    A novel resonant switch operating under the principle of zero-voltage switching is presented. In contrast to the zero-current switching, this technique eliminates the switching loss and dv/dt noise due to the discharging of MOSFET junction capacitances and the reverse recovery of diodes, and enables the converters to operate at high frequencies. A dc analysis of the converter is carried out. The duality relationship between the zero-current switching technique and the zero-voltage switching technique is derived. The two techniques are compared using an example showing the duality between a current-mode quasi-resonant Buck converter and a voltage-mode quasi-resonant boost converter. A 5-MHz 50 V to 5 V flyback converter employing the zero-voltage switching technique has been implemented. The circuit contains the smallest number of components possible, and yet maintains high efficiency at high switching frequency.

  7. Partial deletion of eNOS gene causes hyperinsulinemic state, unbalance of cardiac insulin signaling pathways and coronary dysfunction independently of high fat diet.

    Directory of Open Access Journals (Sweden)

    Cecilia Vecoli

    Full Text Available Abnormalities in eNOS gene, possibly interacting with high fat diet (HFD, affect peripheral vascular function and glucose metabolism. The relative role of eNOS gene, HFD and metabolic derangement on coronary function has not been fully elucidated. We test whether eNOS gene deficiency per se or in association with HFD modulates coronary function through mechanisms involving molecular pathways related to insulin signaling. Wild type (WT, eNOS-/- and eNOS+/- mice were studied. WT and eNOS+/- mice were fed with either standard or HF diet for 16 weeks and compared with standard diet fed eNOS-/-. Glucose and insulin tolerance tests were performed during the last week of diet. Coronary resistance (CR was measured at baseline and during infusions of acetylcholine (Ach or sodium-nitroprusside (SNP to evaluate endothelium-dependent or independent vasodilation, in the Langendorff isolated hearts. Cardiac expression of Akt and ERK genes as evaluation of two major insulin-regulated signaling pathways involved in the control of vascular tone were assessed by western blot. HFD-fed mice developed an overt diabetic state. Conversely, chow-fed genetically modified mice (in particular eNOS-/- showed a metabolic pattern characterized by normoglycemia and hyperinsulinemia with a limited degree of insulin resistance. CR was significantly higher in animals with eNOS gene deletions than in WT, independently of diet. Percent decrease in CR, during Ach infusion, was significantly lower in both eNOS-/- and eNOS+/- mice than in WT, independently of diet. SNP reduced CR in all groups except eNOS-/-. The cardiac ERK1-2/Akt ratio, increased in animals with eNOS gene deletions compared with WT, independently of diet. These results suggest that the eNOS genetic deficiency, associated or not with HFD, has a relevant effect on coronary vascular function, possibly mediated by increase in blood insulin levels and unbalance in insulin-dependent signaling in coronary vessels

  8. Voltage stability analysis in the new deregulated environment

    Science.gov (United States)

    Zhu, Tong

    Nowadays, a significant portion of the power industry is under deregulation. Under this new circumstance, network security analysis is more critical and more difficult. One of the most important issues in network security analysis is voltage stability analysis. Due to the expected higher utilization of equipment induced by competition in a power market that covers bigger power systems, this issue is increasingly acute after deregulation. In this dissertation, some selected topics of voltage stability analysis are covered. In the first part, after a brief review of general concepts of continuation power flow (CPF), investigations on various matrix analysis techniques to improve the speed of CPF calculation for large systems are reported. Based on these improvements, a new CPF algorithm is proposed. This new method is then tested by an inter-area transaction in a large inter-connected power system. In the second part, the Arnoldi algorithm, the best method to find a few minimum singular values for a large sparse matrix, is introduced into the modal analysis for the first time. This new modal analysis is applied to the estimation of the point of voltage collapse and contingency evaluation in voltage security assessment. Simulations show that the new method is very efficient. In the third part, after transient voltage stability component models are investigated systematically, a novel system model for transient voltage stability analysis, which is a logical-algebraic-differential-difference equation (LADDE), is offered. As an example, TCSC (Thyristor controlled series capacitors) is addressed as a transient voltage stabilizing controller. After a TCSC transient voltage stability model is outlined, a new TCSC controller is proposed to enhance both fault related and load increasing related transient voltage stability. Its ability is proven by the simulation.

  9. Electrode voltage fall and total voltage of a transient arc

    Science.gov (United States)

    Valensi, F.; Ratovoson, L.; Razafinimanana, M.; Masquère, M.; Freton, P.; Gleizes, A.

    2016-06-01

    This paper deals with an experimental study of the components of a transient arc total voltage with duration of a few tens of ms and a current peak close to 1000 A. The cathode tip is made of graphite whereas the flat anode is made either of copper or of graphite; the electrodes gap is a few mm. The analysis of the electrical parameters is supported and validated by fast imaging and by two models: the first one is a 2D physical model of the arc allowing to calculate both the plasma temperature field and the arc voltage; the second model is able to estimate the transient heating of the graphite electrode. The main aim of the study was to detect the possible change of the cathode voltage fall (CVF) during the first instants of the arc. Indeed it is expected that during the first ms the graphite cathode is rather cool and the main mechanism of the electron emission should be the field effect emission, whereas after several tens of ms the cathode is strongly heated and thermionic emission should be predominant. We have observed some change in the apparent CVF but we have shown that this apparent change can be attributed to the variation of the solid cathode resistance. On the other hand, the possible change of CVF corresponding to the transition between a ‘cold’ and a ‘hot’ cathode should be weak and could not be characterized considering our measurement uncertainty of about 2 V. The arc column voltage (ACV) was estimated by subtracting the electrode voltage fall from the total arc voltage. The experimental transient evolution of the ACV is in very good agreement with the theoretical variation predicted by the model, showing the good ability of the model to study this kind of transient arc.

  10. Unbalanced Voltage Compensation in Low Voltage Residential AC Grids

    DEFF Research Database (Denmark)

    Trintis, Ionut; Douglass, Philip; Munk-Nielsen, Stig

    2016-01-01

    This paper describes the design and test of a control algorithm for active front-end rectifiers that draw power from a residential AC grid to feed heat pump loads. The control algorithm is able to control the phase to neutral or phase to phase RMS voltages at the point of common coupling....... The voltage control was evaluated with either active or reactive independent phase load current control. The control performance in field operation in a residential grid situated in Bornholm, Denmark was investigated for different use cases....

  11. Automated Voltage Control in LHCb

    CERN Document Server

    Granado Cardoso, L; Jacobsson, R

    2011-01-01

    LHCb is one of the 4 LHC experiments. In order to ensure the safety of the detector and to maximize efficiency, LHCb needs to coordinate its own operations, in particular the voltage configuration of the different subdetectors, according to the accelerator status. A control software has been developed for this purpose, based on the Finite State Machine toolkit and the SCADA system used for control throughout LHCb (and the other LHC experiments). This software permits to efficiently drive both the Low Voltage (LV) and High Voltage (HV) systems of the 10 different sub-detectors that constitute LHCb, setting each sub-system to the required voltage (easily configurable at run-time) based on the accelerator state. The control software is also responsible for monitoring the state of the Sub-detector voltages and adding it to the event data in the form of status-bits. Safe and yet flexible operation of the LHCb detector has been obtained and automatic actions, triggered by the state changes of the ...

  12. Development of a New Cascade Voltage-Doubler for Voltage Multiplication

    OpenAIRE

    Arash Toudeshki; Norman Mariun; Hashim Hizam; Noor Izzri Abdul Wahab

    2014-01-01

    For more than eight decades, cascade voltage-doubler circuits are used as a method to produce DC output voltage higher than the input voltage. In this paper, the topological developments of cascade voltage-doublers are reviewed. A new circuit configuration for cascade voltage-doubler is presented. This circuit can produce a higher value of the DC output voltage and better output quality compared to the conventional cascade voltage-doubler circuits, with the same number of stages.

  13. Low-Energy Real-Time OS Using Voltage Scheduling Algorithm for Variable Voltage Processors

    OpenAIRE

    Okuma, Takanori; Yasuura, Hiroto

    2001-01-01

    This paper presents a real-time OS based on $ mu $ITRON using proposed voltage scheduling algorithm for variable voltage processors which can vary supply voltage dynamically. The proposed voltage scheduling algorithms assign voltage level for each task dynamically in order to minimize energy consumption under timing constraints. Using the presented real-time OS, running tasks with low supply voltage leads to drastic energy reduction. In addition, the presented voltage scheduling algorithm is ...

  14. Simple buck/boost voltage regulator

    Science.gov (United States)

    Paulkovich, J.; Rodriguez, G. E.

    1980-01-01

    Circuit corrects low or high supply voltage, produces regulated output voltage. Circuit has fewer components because inductory/transformer combination and pulse-width modulator serve double duty. Regulator handles input voltage variation from as low as one half output voltage to as high as input transistor rating. Solar arrays, fuel cells, and thermionic generators might use this regulator.

  15. 30 CFR 18.47 - Voltage limitation.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Voltage limitation. 18.47 Section 18.47 Mineral... § 18.47 Voltage limitation. (a) A tool or switch held in the operator's hand or supported against his... particular voltage(s) are provided in the design and construction of the equipment, its wiring,...

  16. High-Voltage, Low-Power BNC Feedthrough Terminator

    Science.gov (United States)

    Bearden, Douglas

    2012-01-01

    This innovation is a high-voltage, lowpower BNC (Bayonet Neill-Concelman) feedthrough that enables the user to terminate an instrumentation cable properly while connected to a high voltage, without the use of a voltage divider. This feedthrough is low power, which will not load the source, and will properly terminate the instrumentation cable to the instrumentation, even if the cable impedance is not constant. The Space Shuttle Program had a requirement to measure voltage transients on the orbiter bus through the Ground Lightning Measurement System (GLMS). This measurement has a bandwidth requirement of 1 MHz. The GLMS voltage measurement is connected to the orbiter through a DC panel. The DC panel is connected to the bus through a nonuniform cable that is approximately 75 ft (approximately equal to 23 m) long. A 15-ft (approximately equal to 5-m), 50-ohm triaxial cable is connected between the DC panel and the digitizer. Based on calculations and simulations, cable resonances and reflections due to mismatched impedances of the cable connecting the orbiter bus and the digitizer causes the output not to reflect accurately what is on the bus. A voltage divider at the DC panel, and terminating the 50-ohm cable properly, would eliminate this issue. Due to implementation issues, an alternative design was needed to terminate the cable properly without the use of a voltage divider. Analysis shows how the cable resonances and reflections due to the mismatched impedances of the cable connecting the orbiter bus and the digitizer causes the output not to reflect accurately what is on the bus. After simulating a dampening circuit located at the digitizer, simulations were performed to show how the cable resonances were dampened and the accuracy was improved significantly. Test cables built to verify simulations were accurate. Since the dampening circuit is low power, it can be packaged in a BNC feedthrough.

  17. Cavity Voltage Phase Modulation MD

    CERN Document Server

    Mastoridis, Themistoklis; Molendijk, John; Timko, Helga; CERN. Geneva. ATS Department

    2016-01-01

    The LHC RF/LLRF system is currently configured for extremely stable RF voltage to minimize transient beam loading effects. The present scheme cannot be extended beyond nominal beam current since the demanded power would exceed the peak klystron power and lead to saturation. A new scheme has therefore been proposed: for beam currents above nominal (and possibly earlier), the cavity phase modulation by the beam will not be corrected (transient beam loading), but the strong RF feedback and One-Turn Delay feedback will still be active for loop and beam stability in physics. To achieve this, the voltage set point will be adapted for each bunch. The goal of this MD was to test a new algorithm that would adjust the voltage set point to achieve the cavity phase modulation that would minimize klystron forward power.

  18. Portable High Voltage Impulse Generator

    Directory of Open Access Journals (Sweden)

    S. Gómez

    2011-07-01

    Full Text Available This paper presents a portable high voltage impulse generator which was designed and built with insulation up to 20 kV. This design was based on previous work in which simulation software for standard waves was developed. Commercial components and low-cost components were used in this work; however, these particular elements are not generally used for high voltage applications. The impulse generators used in industry and laboratories are usually expensive; they are built to withstand extra high voltage and they are big, making them impossible to transport. The proposed generator is portable, thereby allowing tests to be made on devices that cannot be moved from their location. The results obtained with the proposed impulse generator were satisfactory in terms of time and waveforms compared to other commercial impulse generators and the standard impulse wave simulator.

  19. Superficial characterization and nano structural of nano multilayers Cr/Cr N obtained by UBM with different unbalance grades; Caracterizacion superficial y nano estructural de nano multicapas Cr/CrN obtenidas por UBM con diferentes grados de desbalance

    Energy Technology Data Exchange (ETDEWEB)

    Piratoba, U. [Universidad Nacional de Colombia, Departamento de Fisica, Carrera 45 No. 26-85, Edificio Uriel Gutierrez, Bogota D. C. (Colombia); Arenas A, J. [UNAM, Instituto de Fisica, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Olaya, J. J., E-mail: ulisesp3@hotmail.com [Universidad Nacional de Colombia, Departamento de Ingenieria Mecanica y Mecatronica, Carrera 30 No. 45-03, Edificio 453, Bogota D. C. (Colombia)

    2013-10-01

    Coatings of 25 bilayers of Cr/Cr N, with total thickness between 1.32 and 1.67 microns, were deposited by reactive sputtering on silicon and H13 steel, in argon and argon with nitrogen atmospheres. A power of 160 watts, flows of argon and nitrogen of 9 and 3 sc cm respectively, and an axial unbalanced magnetron, whose coefficient of geometrical unbalance K{sub G} was varied between 0.85 and 1.37. Of these coatings, micrographs of surface and cross section scanning electron microscopy were obtained, was make a micro structural characterization with X-ray diffraction, a nano structural characterization by transmission electron microscopy, and surface characterization by atomic force microscopy in tapping mode: analysis showed uniform surface coating with globular and pyramidal formations, which contain some granular inclusions and microscopic craters. With the increase in the unbalance of the magnetic field, the grain size, the roughness and the speed of the coatings growth were increased. (Author)

  20. 跆拳道运动员临场与赛中心理失衡及干预研究%Researches on Pre-competition and Running-competition Psychological Unbalance and Its Interventions of Teakwondo Athletes

    Institute of Scientific and Technical Information of China (English)

    张玉强; 张祖强

    2013-01-01

    对跆拳道运动员临场及赛中心理失衡表现及原因进行剖析,阐述心理失衡的表现形式,从教练员干预技法、赛前心理训练及赛中教练员心理辅导及运动员心理自助三个方面提出调节心理失衡的训练目标及方法。旨在通过赛前及赛中有针对性的训练,在最短时间内调节好心理平衡,使运动员在临赛及赛中保持理想的竞技心理状态。%This essay analyzes the behaviors and reasons of pre -competition and running -competition psychological unbalance of teakwondo athletes from the perspectives of coach intervention methods , pre-competition psychological trainings , coach psycho-logical counseling and self -help psychological counselling during running -competition, this essay brings forward the trainning goals and methods for adjusting psychological unbalance .The purpose of these are to make teakwondo athletes maintain better psy-chological state during pre -competition and running -competition.

  1. Cooperative Control with Virtual Selective Harmonic Capacitance for Harmonic Voltage Compensation in Islanded MicroGrids

    DEFF Research Database (Denmark)

    Micallef, A.; Apap, M.; Spitero-Stanies, C.

    2012-01-01

    This paper focuses on the islanded operation of microgrids. In this mode of operation, the microsources are required to cooperate autonomously to regulate the local grid voltage and frequency. Droop control is typically used to achieve this autonomous voltage and frequency regulation. Inverters...... having LCL output filters would cause voltage distortion to be present at the PCC of the local load when non-linear current is supplied to the load due to the voltage drop across the grid side inductor. Techniques to reduce the output voltage distortion typically consist of installing either passive...... loop, implemented in each of the microsource inverters, is proposed so as to dampen the voltage harmonics at the PCC of the local load. Simulation results are presented showing the suitability of the proposed algorithm in dampening the PCC voltage harmonics....

  2. A low voltage CMOS low drop-out voltage regulator

    Science.gov (United States)

    Bakr, Salma Ali; Abbasi, Tanvir Ahmad; Abbasi, Mohammas Suhaib; Aldessouky, Mohamed Samir; Abbasi, Mohammad Usaid

    2009-05-01

    A low voltage implementation of a CMOS Low Drop-Out voltage regulator (LDO) is presented. The requirement of low voltage devices is crucial for portable devices that require extensive computations in a low power environment. The LDO is implemented in 90nm generic CMOS technology. It generates a fixed 0.8V from a 2.5V supply which on discharging goes to 1V. The buffer stage used is unity gain configured unbuffered OpAmp with rail-to-rail swing input stage. The simulation result shows that the implemented circuit provides load regulation of 0.004%/mA and line regulation of -11.09mV/V. The LDO provides full load transient response with a settling time of 5.2μs. Further, the dropout voltage is 200mV and the quiescent current through the pass transistor (Iload=0) is 20μA. The total power consumption of this LDO (excluding bandgap reference) is only 80μW.

  3. Implementation of Dynamic Voltage Restorer for Mitigation of Voltage Sag

    Directory of Open Access Journals (Sweden)

    K.Vinod Kumar

    2013-07-01

    Full Text Available Power quality is one of major concerns in the present. It has become important, especially with the introduction of sophisticated devices, whose performance is very sensitive to the quality of power supply. The dynamic voltage restorer (DVR is one of the modern devices used in distribution systems to improve the power quality. In this paper, emergency control in distribution systems is discussed by using the proposed multifunctional DVR control strategy.Also, themultiloop controller using the Posicast and P+Resonant controllers is proposed in order to improve the transient response and eliminate the steady state error in DVR response,respectively.The proposed process is applied to some riots in load voltage effected by induction motors starting, and a three-phase short circuit fault. The three-phase short circuits, and the large induction motors are suddenly started then voltage sags areoccurred.The innovation here is that by using the Multifunctional Dynamic Voltage Restorer, improve the power quality in distribution side. Simulation results show the capability of the DVR to control the emergency conditions of the distribution systems by using MATLAB/Simulink software.

  4. The high voltage homopolar generator

    Science.gov (United States)

    Price, J. H.; Gully, J. H.; Driga, M. D.

    1986-11-01

    System and component design features of proposed high voltage homopolar generator (HVHPG) are described. The system is to have an open circuit voltage of 500 V, a peak output current of 500 kA, 3.25 MJ of stored inertial energy and possess an average magnetic-flux density of 5 T. Stator assembly components are discussed, including the stator, mount structure, hydrostatic bearings, main and motoring brushgears and rotor. Planned operational procedures such as monitoring the rotor to full speed and operation with a superconducting field coil are delineated.

  5. Resilient architecture design for voltage variation

    CERN Document Server

    Reddi, Vijay Janapa

    2013-01-01

    Shrinking feature size and diminishing supply voltage are making circuits sensitive to supply voltage fluctuations within the microprocessor, caused by normal workload activity changes. If left unattended, voltage fluctuations can lead to timing violations or even transistor lifetime issues that degrade processor robustness. Mechanisms that learn to tolerate, avoid, and eliminate voltage fluctuations based on program and microarchitectural events can help steer the processor clear of danger, thus enabling tighter voltage margins that improve performance or lower power consumption. We describe

  6. A NOVEL METHOD OF VOLTAGE SAG AND SWELL ESTIMATION FOR POWER SYSTEM APPLICATIONS

    Directory of Open Access Journals (Sweden)

    A. Vetrivel

    2013-01-01

    Full Text Available This study presents four simple mathematical models to build the voltage shape with the knowledge of few parameters and detects voltage sag and swells accurately. Fourier series, cubic polynomial, Rational functions and Sum of Sin functions are used in this study to model the voltage profile. A new algorithm is developed to detect sag or swell in all the four models. The voltage estimation due to cubic polynomial has more voltage error and then rational function. The sum of sine function and Fourier series functions does accurate voltage estimation. Errors due to various functions are also tabulated for one electrical cycle. The performance of each method has been compared with other to know the effectiveness of different models and their results are presented.

  7. Updated equation to compute the soil voltage contour under fault condition

    Directory of Open Access Journals (Sweden)

    M. Nassereddine, J. Rizk, M. Nagrial, A. Hellany

    2015-01-01

    Full Text Available The neighboring rates between high voltage substation and residential buildings are amplified due to populations increase. Under fault or system malfunction, earth potential rise could reach an unsafe condition. This earth potential rise extends to the surrounding soil and known as the soil voltage. To guarantee safety acquiescence of the new system, earthing system design is required. Earthing system offers a safe working atmosphere for employees and people transitory by during a fault or malfunction of a power system. The soil voltage due to high voltage EPR plays important roles when it comes to step and touch voltage computation. In this paper, a new equation is studied to compute the soil voltage at distance x from the fault location. Numerous field tests is included to verify the proposed method.

  8. Frequency-controlled voltage regulator

    Science.gov (United States)

    Mclyman, W. T.

    1980-01-01

    Converting input ac to higher frequency reduce size and weight and makes possible unique kind of regulation. Since conversion frequency is above range of human hearing, supply generated on audible noise. It also exploits highfrequency conversion features to regulate its output voltage in novel way. Circuit is inherently short-circuit proof.

  9. Low-voltage coherent electron imaging based on a single-atom electron

    OpenAIRE

    Chang, Wei-Tse; Lin, Chun-Yueh; Hsu, Wei-Hao; Chang, Mu-Tung; Chen, Yi-Sheng; Hwu, En-Te; Hwang, Ing-Shouh

    2015-01-01

    It has been a general trend to develop low-voltage electron microscopes due to their high imaging contrast of the sample and low radiation damage. Atom-resolved transmission electron microscopes with voltages as low as 15-40 kV have been demonstrated. However, achieving atomic resolution at voltages lower than 10 kV is extremely difficult. An alternative approach is coherent imaging or phase retrieval imaging, which requires a sufficiently coherent source and an adequately small detection are...

  10. Voltage-gated Proton Channels

    Science.gov (United States)

    DeCoursey, Thomas E.

    2014-01-01

    Voltage-gated proton channels, HV1, have vaulted from the realm of the esoteric into the forefront of a central question facing ion channel biophysicists, namely the mechanism by which voltage-dependent gating occurs. This transformation is the result of several factors. Identification of the gene in 2006 revealed that proton channels are homologues of the voltage-sensing domain of most other voltage-gated ion channels. Unique, or at least eccentric, properties of proton channels include dimeric architecture with dual conduction pathways, perfect proton selectivity, a single-channel conductance ~103 smaller than most ion channels, voltage-dependent gating that is strongly modulated by the pH gradient, ΔpH, and potent inhibition by Zn2+ (in many species) but an absence of other potent inhibitors. The recent identification of HV1 in three unicellular marine plankton species has dramatically expanded the phylogenetic family tree. Interest in proton channels in their own right has increased as important physiological roles have been identified in many cells. Proton channels trigger the bioluminescent flash of dinoflagellates, facilitate calcification by coccolithophores, regulate pH-dependent processes in eggs and sperm during fertilization, secrete acid to control the pH of airway fluids, facilitate histamine secretion by basophils, and play a signaling role in facilitating B-cell receptor mediated responses in B lymphocytes. The most elaborate and best-established functions occur in phagocytes, where proton channels optimize the activity of NADPH oxidase, an important producer of reactive oxygen species. Proton efflux mediated by HV1 balances the charge translocated across the membrane by electrons through NADPH oxidase, minimizes changes in cytoplasmic and phagosomal pH, limits osmotic swelling of the phagosome, and provides substrate H+ for the production of H2O2 and HOCl, reactive oxygen species crucial to killing pathogens. PMID:23798303

  11. Relation and Influence of All Kinds of Unbalance Torques of Three Degrees of Freedom Air-bearing Spacecraft Simulator Caused by Gravity%重力引起的3自由度气浮台各类不平衡力矩关系及影响

    Institute of Scientific and Technical Information of China (English)

    李延斌; 向东; 高有华

    2015-01-01

    To improve three degrees of freedom air-bearing simulation accuracy and reduce the influence of unbalance torque caused by gravity, a method for calculating and compensating elastic unbalance torque is proposed. After computational model of static, plastic, gravity gradient and total unbalance torque being established, the relation and influence among all kinds of unbalance torque cause by gravity are analysis. It is discovered by contrast that static unbalance torque plays an important role when the platform mass center is far away from the rotation center. With the mass center approaching to rotation center, elastic unbalance torque is gradually becoming the main factor affecting the air-bearing platform balance. Then closing the distance between mass center and rotation center has nothing to do on reducing the unbalance torque, which shows that elastic unbalance torque is the main limiting factor for improving platform accuracy. The principle for mutual compensation between static unbalance torque and elastic unbalance torque is proposed and the compensation algorithm with automatic balancing system is provided. Experimental results have demonstrated application of the compensation method is an important channel for reducing unbalance torque.%为了提高3自由度气浮台的仿真精度,减小重力引起不平衡力矩的影响,提出气浮台弹性不平衡力矩的计算及补偿方法.建立气浮台重力引起的静态、弹性、重力梯度和总不平衡力矩的计算模型,分析重力引起的各类不平衡力矩关系及影响.通过对比发现气浮台质心位置相对回转中心较远时,静态不平衡力矩起主要作用.随着质心位置接近回转中心,弹性不平衡力矩逐渐成为影响气浮台平衡的主要因素,此时质心位置与回转中心距离的减小已不起作用,说明弹性不平衡力矩是制约气浮台精度提高的主要因素.提出静态不平衡力矩与弹性不平衡力矩相互补偿的原理,

  12. Current-voltage model of LED light sources

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2012-01-01

    Amplitude modulation is rarely used for dimming light-emitting diodes in polychromatic luminaires due to big color shifts caused by varying magnitude of LED driving current and nonlinear relationship between intensity of a diode and driving current. Current-voltage empirical model of light...

  13. Effect of bleeding method and low voltage electrical stimulation on ...

    African Journals Online (AJOL)

    None the less, personal observations would recommend the use of TS due ... Electrical stimulation also had no effect on the Warner Bratzler shear force values in the fillet. It can be concluded that low voltage ES has no advantage pertaining to ...

  14. Distributed Control to Ensure Proportional Load Sharing and Improve Voltage Regulation in Low-Voltage DC Microgrids

    DEFF Research Database (Denmark)

    Anand, Sandeep; G. Fernandes, Baylon; Guerrero, Josep M.

    2013-01-01

    DC microgrids are gaining popularity due to high efficiency, high reliability, and easy interconnection of renewable sources as compared to the ac system. Control objectives of dc microgrid are: 1) to ensure equal load sharing (in per unit) among sources; and 2) to maintain low-voltage regulation...

  15. Over-voltage protection system and method

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Song; Dong, Dong; Lai, Rixin

    2017-05-02

    An over-voltage protection system includes an electronic valve connected across two terminals of a circuit and an over-voltage detection circuit connected across one of the plurality of semiconductor devices for detecting an over-voltage across the circuit. The electronic valve includes a plurality of semiconductor devices connected in series. The over-voltage detection circuit includes a voltage divider circuit connected to a break-over diode in a way to provide a representative low voltage to the break-over diode and an optocoupler configured to receive a current from the break-over diode when the representative low voltage exceeds a threshold voltage of the break-over diode indicating an over-voltage condition. The representative low voltage provided to the break-over diode represents a voltage across the one semiconductor device. A plurality of self-powered gate drive circuits are connected to the plurality of semiconductor devices, wherein the plurality of self-powered gate drive circuits receive over-voltage triggering pulses from the optocoupler during the over-voltage condition and switch on the plurality of semiconductor devices to bypass the circuit.

  16. OFCC based voltage and transadmittance mode instrumentation amplifier

    Science.gov (United States)

    Nand, Deva; Pandey, Neeta; Pandey, Rajeshwari; Tripathi, Prateek; Gola, Prashant

    2017-07-01

    The operational floating current conveyor (OFCC) is a versatile active block due to the availability of both low and high input and output impedance terminals. This paper addresses the realization of OFCC based voltage and transadmittance mode instrumentation amplifiers (VMIA and TAM IA). It employs three OFCCs and seven resistors. The transadmittance mode operation can easily be obtained by simply connecting an OFCC based voltage to current converter at the output. The effect of non-idealities of OFCC, in particular finite transimpedance and tracking error, on system performance is also dealt with and corresponding mathematical expressions are derived. The functional verification is performed through SPICE simulation using CMOS based implementation of OFCC.

  17. Control and Protection Cooperation Strategy for Voltage Instability

    DEFF Research Database (Denmark)

    Liu, Zhou; Chen, Zhe; Sun, Haishun;

    2012-01-01

    Most cascaded blackouts are caused by unexpected backup relay operations due to low voltage or overload state caused by post fault load restoration dynamics. If such state can be sensed and adjusted appropriately prior to those relay actions, system stability might be sustained. This paper proposed...... a control and protection cooperation strategy to prevent post fault voltage instability. The multi-agent technology is applied for the strategy implementation; the criteria based on wide area measured apparent impedances are defined to choose the control strategy, such as tap changer adjusting or load...

  18. Control Strategy for Microgrid Inverter under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Liu, Wenzhao; Zhang, X.

    2014-01-01

    This paper presents the theoretical analysis of the inherent reason of current harmonic and power oscillation phenomena in case of operating the microgrid inverter under unbalanced grid voltage conditions. In order to flexibly control the current harmonic and power oscillation, a new stationary...... frame control strategy is proposed. It has a simple control structure due to no need of a phase-locked loop and voltage/current positive/negative sequence extraction calculation. The coordinate control of power and current quality is achieved, which enhances the operation performance of microgrid...

  19. Bidirectional current-voltage converters based on magnetostrictive/piezoelectric composites

    NARCIS (Netherlands)

    Jia, Y.; Or, S.W.; Chan, H.L.W.; Jiao, J.; Luo, H.; Van der Zwaag, S.

    2009-01-01

    We report a power supply-free, bidirectional electric current-voltage converter based on a coil-wound laminated composite of magnetostrictive alloy and piezoelectric crystal. An electric current applied to the coil induces a magnetic field, resulting in an electric voltage from the composite due to

  20. Impact Study of Electric Vehicle (EV) Integration on Medium Voltage (MV) Grids

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Nielsen, Arne Hejde; Østergaard, Jacob

    2011-01-01

    The impact study of electric vehicle (EV) grid integration on medium voltage (MV) grids was carried out to quantify the power component loading and voltage profile change in MV grids due to the extra demands from the EV charging. Three charging scenarios, dumb charging, time charging and fleet...

  1. Effect of voltage sags on digitally controlled line connected switched-mode power supplies

    DEFF Research Database (Denmark)

    Török, Lajos; Munk-Nielsen, Stig

    2012-01-01

    Different voltage disorders like voltage fluctuations, sags, frequency variations may occur in the power supply networks due to different fault conditions. These deviations from normal operation affects in different ways the line connected devices. Standards were developed to protect and ensure i...

  2. Location, Tilt, and Binding : A Molecular Dynamics Study of Voltage-Sensitive Dyes in Biomembranes

    NARCIS (Netherlands)

    Hinner, Marlon J.; Marrink, Siewert-J.; de Vries, Alex H.

    2009-01-01

    We present a molecular dynamics study on the interaction of styryl-type voltage-sensitive dyes with a lipid membrane. In this work, voltage-sensitive dyes are proposed as interesting model amphiphiles for biomolecular simulation, due to the wealth of biophysical and thermodynamical data available on

  3. Electronics drivers for high voltage dielectric electro active polymer (DEAP) applications

    DEFF Research Database (Denmark)

    Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    ), but the voltage balancing across the series - connected high voltage IGBTs is a critical issue and accordi ngly a novel gate driver circuitry is proposed and equipped; due to the requirements of the audio products, such as low distortion and noise, the multi - level Buck converter based Class - D amplifier...

  4. Advances in high voltage engineering

    CERN Document Server

    Haddad, A

    2005-01-01

    This book addresses the very latest research and development issues in high voltage technology and is intended as a reference source for researchers and students in the field, specifically covering developments throughout the past decade. This unique blend of expert authors and comprehensive subject coverage means that this book is ideally suited as a reference source for engineers and academics in the field for years to come.

  5. High Voltage Pulse Testing Survey.

    Science.gov (United States)

    1985-10-01

    Cryogenic 23 E. Liquids 26 F. Solids 28 1. Polyethylene 28 2. Cross-Linked Polyethylene ( XLPE ) 29 3. Polyimide and Polyvenylchloride (PVC) 31 VI Benefits 35 A...Strength of XLPE Cables 29 vii * 4" I PROGRAM OBJECTIVES The Pulse Test Survey summarizes government, industry, and technical reports on high voltage pulse...system of silicone oil on a XLPE (cross-linked polyethylene) spacer tends to lower the impulse breakdown by approximately 10 percent. The negative impulse

  6. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    Science.gov (United States)

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  7. Low voltage electron beam accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, Masafumi [Iwasaki Electric Co., Ltd., Tokyo (Japan)

    2003-02-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  8. Voltage Stability Improvement of Grid Connected Wind Driven Induction Generator Using Svc

    Directory of Open Access Journals (Sweden)

    Ruchi Aggarwal

    2014-05-01

    Full Text Available Voltage stability is one of the major problem associated with wind power generating system which may be due to fluctuating nature of wind, heavy load, fault occurrence or insufficient reactive power supply. The wind power generating system most commonly employed with squirrel cage induction generator(SCIG that needs the support of an external device such as capacitor bank, FACTS devices etc. to support reactive power in order to remain connected with the grid during voltage dips. The voltage stability of a wind driven induction generator can be improved by using FACTS devices such as SVC, STATCOM.In this paper svc is used for voltage stability improvement.

  9. Secondary control for reactive power sharing and voltage amplitude restoration in droop-controlled islanded microgrids

    DEFF Research Database (Denmark)

    Micallef, A.; Apap, M.; Spiteri Staines, C.

    2012-01-01

    This paper focuses on the islanded operation of microgrids. In this mode of operation, the microsources are required to cooperate autonomously to regulate the local grid voltage and frequency. Droop control is typically used to achieve this autonomous voltage and frequency regulation. However...... and to restore the voltage deviations caused by the droop control. Primary droop control loops where implemented in the inverters to supply the real and reactive power. Simulation results are presented showing the feasibility of the proposed algorithm in achieving reactive power sharing between the inverters...... connected to the microgrid while simultaneously restoring the voltage deviations due to the droop control....

  10. Energy reduction through voltage scaling and lightweight checking

    Science.gov (United States)

    Kadric, Edin

    , and we get diminishing returns from continuing to scale voltage. To ensure that memories do not become a bottleneck, we also design an energy-robust FPGA memory architecture, which attempts to minimize communication energy due to mismatches between application and architecture. We do this alongside application parallelism tuning. We show our techniques on a wide range of applications, including a large real-time system used for Wide-Area Motion Imaging (WAMI).

  11. Adaptive Voltage Management Enabling Energy Efficiency in Nanoscale Integrated Circuits

    Science.gov (United States)

    Shapiro, Alexander E.

    Battery powered devices emphasize energy efficiency in modern sub-22 nm CMOS microprocessors rendering classic power reduction solutions not sufficient. Classical solutions that reduce power consumption in high performance integrated circuits are superseded with novel and enhanced power reduction techniques to enable the greater energy efficiency desired in modern microprocessors and emerging mobile platforms. Dynamic power consumption is reduced by operating over a wide range of supply voltages. This region of operation is enabled by a high speed and power efficient level shifter which translates low voltage digital signals to higher voltages (and vice versa), a key component that enables communication among circuits operating at different voltage levels. Additionally, optimizing the wide supply voltage range of signals propagating across long interconnect enables greater energy savings. A closed-form delay model supporting wide voltage range is developed to enable this capability. The model supports an ultra-wide voltage range from nominal voltages to subthreshold voltages, and a wide range of repeater sizes. To mitigate the drawback of lower operating speed at reduced supply voltages, the high performance exhibited by MOS current mode logic technology is exploited. High performance and energy efficient circuits are enabled by combining this logic style with power efficient near threshold circuits. Many-core systems that operate at high frequencies and process highly parallel workloads benefit from this combination of MCML with NTC. Due to aggressive scaling, static power consumption can in some cases overshadow dynamic power. Techniques to lower leakage power have therefore become an important objective in modern microprocessors. To address this issue, an adaptive power gating technique is proposed. This technique utilizes high levels of granularity to save additional leakage power when a circuit is active as opposed to standard power gating that saves static

  12. Piezo Voltage Controlled Planar Hall Effect Devices

    OpenAIRE

    Bao Zhang; Kang-Kang Meng; Mei-Yin Yang; Edmonds, K. W.; Hao Zhang; Kai-Ming Cai; Yu Sheng; Nan Zhang; Yang Ji; Jian-Hua Zhao; Hou-Zhi Zheng; Kai-You Wang

    2015-01-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the pie...

  13. Effects of Nonlinearities on Induced Voltages across Lumped Devices

    Directory of Open Access Journals (Sweden)

    Ziya Mazloom

    2011-01-01

    Full Text Available There have been many studies on induced currents and voltages along overhead conductors due to lightning flashes. In most of these studies lumped loads and components are connected only as line terminations [1]-[4]. In studies where series and shunt connected components are connected along the lines the effects of nonlinear components and effects are disregarded [5]-[8]. This is not always correct as nonlinear effects will introduce high frequencies in the system and affect the current and voltage wave distribution. In this paper the effects of series and shunt components and nonlinear phenomenon on a system representative of the Swedish electrified railway system will be investigated. It is seen how introduction of different linear and nonlinear components affect the propagating voltage wave forms.

  14. A Comparative Study of Ultra-Low Voltage Digital Circuit Design

    Directory of Open Access Journals (Sweden)

    Aaron Arthurs

    2012-07-01

    Full Text Available Ultra-low voltage digital circuit design is an active research area, especially for portable applications such as wearable electronics, intelligent remote sensors, implantable medical devices, and energy-harvesting systems. Due to their application scenarios and circuit components, two major goals for these systems are minimizing energy consumption and improving compatibility with low-voltage power supplies and analog components. The most effective solution to achieve these goals is to reduce the supply voltage, which,however, raises the issue of operability. At ultra-low supply voltages, the integrity of digital signals degrades dramatically due to the indifference between active and leakage currents. In addition, the system timing becomes more unpredictable as the impact of process and supply voltage variations being more significant at lower voltages. This paper presents a comparative study among three techniques for designing digital circuits operating at ultra-low voltages, i.e., Schmitt-triggered gate structure, delayinsensitive asynchronous logic, and Fully-Depleted Silicon-on-Insulator technology. Results show that despite the tradeoffs, all eight combinations of these techniques are viable for designing ultra-low voltage circuits. For a given application, the optimum circuit design can be selected from these combinations based on the lowest voltage, the dynamic range, the power budget, the performance requirement, and the available semiconductor process node.

  15. A Comparative Study of Ultra-Low Voltage Digital Circuit Design

    Directory of Open Access Journals (Sweden)

    Aaron Arthurs,

    2012-06-01

    Full Text Available Ultra-low voltage digital circuit design is an active research area, especially for portable applications such as wearable electronics, intelligent remote sensors, implantable medical devices, and energy-harvesting systems. Due to their application scenarios and circuit components, two major goals for these systems are minimizing energy consumption and improving compatibility with low-voltage power supplies and analog components. The most effective solution to achieve these goals is to reduce the supply voltage, which,however, raises the issue of operability. At ultra-low supply voltages, the integrity of digital signals degrades dramatically due to the indifference between active and leakage currents. In addition, the system timing becomes more unpredictable as the impact of process and supply voltage variations being more significant at lower voltages. This paper presents a comparative study among three techniques for designing digital circuits operating at ultra-low voltages, i.e., Schmitt-triggered gate structure, delay insensitive asynchronous logic, and Fully-Depleted Silicon-on-Insulator technology. Results show that despite the trade offs, all eight combinations of these techniques are viable for designing ultra-low voltage circuits. For a given application, the optimum circuit design can be selected from these combinations based on the lowest voltage, the dynamic range, the power budget, the performance requirement, and the available semiconductor process node.

  16. 49 CFR 234.221 - Lamp voltage.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lamp voltage. 234.221 Section 234.221 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall...

  17. Bootstrapped Low-Voltage Analog Switches

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    1999-01-01

    Novel low-voltage constant-impedance analog switch circuits are proposed. The switch element is a single MOSFET, and constant-impedance operation is obtained using simple circuits to adjust the gate and bulk voltages relative to the switched signal. Low-voltage (1-volt) operation is made feasible...

  18. Series-connected substrate-integrated lead-carbon hybrid ultracapacitors with voltage-management circuit

    Indian Academy of Sciences (India)

    A Banerjee; R Srinivasan; A K Shukla

    2015-02-01

    Cell voltage for a fully charged-substrate-integrated lead-carbon hybrid ultracapacitor is about 2.3 V. Therefore, for applications requiring higher DC voltage, several of these ultracapacitors need to be connected in series. However, voltage distribution across each series-connected ultracapacitor tends to be uneven due to tolerance in capacitance and parasitic parallel-resistance values. Accordingly, voltage-management circuit is required to protect constituent ultracapacitors from exceeding their rated voltage. In this study, the design and characterization of the substrate-integrated lead-carbon hybrid ultracapacitor with co-located terminals is discussed. Voltage-management circuit for the ultracapacitor is presented, and its effectiveness is validated experimentally.

  19. Interface circuit with adjustable bias voltage enabling maximum power point tracking of capacitive energy harvesting devices

    Science.gov (United States)

    Wei, J.; Lefeuvre, E.; Mathias, H.; Costa, F.

    2016-12-01

    The operation analysis of a new interface circuit for electrostatic vibration energy harvesting with adjustable bias voltage is carried out in this paper. Two configurations determined by the open or closed states of an electronic switch are examined. The increase of the voltage across a biasing capacitor, occurring when the switch is open, is proved theoretically and experimentally. With the decrease of this biasing voltage which occurs naturally when the switch is closed due to imperfections of the circuit, the bias voltage can be maintained close to a target value by appropriate ON and OFF control of the switch. As the energy converted by the variable capacitor on each cycle depends on the bias voltage, this energy can be therefore accurately controlled. This feature opens up promising perspectives for optimization the power harvested by electrostatic devices. Simulation results with and without electromechanical coupling effect are presented. In experimental tests, a simple switch control enabling to stabilize the bias voltage is described.

  20. Voltage-Balancing Method for Modular Multilevel Converters Switched at Grid Frequency

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2015-01-01

    The modular multilevel converter (MMC) becomes attractive for high-voltage and high-power applications due to its high modularity, availability, and power quality. The voltage balance issue of capacitors is very important in the MMC, and the balancing of the capacitor voltage is increasingly...... difficult as the switching frequency is reduced. In this paper, a voltage-balancing method is proposed for the MMC switched at grid frequency with reduced losses and does not rely on the arm current. By assigning the low-frequency pulses with different pulse widths, the capacitor charge transfer in the MMC...... can be controlled for keeping the capacitor voltage balancing in the MMC. Simulations and experimental studies of the MMC are conducted, and the results confirm the effectiveness of the proposed capacitor voltage-balancing method....

  1. 基于PSO-GRNN的直升机旋翼不平衡故障诊断%Fault Diagnosis of Helicopter Rotor’s Unbalance Based on PSO-GRNN Algorithms

    Institute of Scientific and Technical Information of China (English)

    谢习华; 徐雷; 谭耀; 马云荣

    2015-01-01

    In order to diagnose the helicopter rotor’s unbalance fault accurately, a method based on particle swarm opti-mization (PSO) algorithm and generalized regression neural network (PSO-GRNN) was proposed. The average mean square error obtained from cross validation was used as the fitness function of the particle swarm. Then, the optimal GRNN smooth factor was attained by using the PSO algorithm, and an optimal model for fault diagnosis was achieved. It can be concluded that based on the PSO-GRNN model, the type and the extent of the helicopter rotor’s unbalance can be diagnosed effective-ly, the accuracy rate of fault type is up to 94.29%and the maximum error of fault degree is only 6.54%, which satisfies the requirement of engineering projects perfectly.%为了准确诊断直升机旋翼不平衡故障,提出了一种基于粒子群算法和广义回归神经网络模型(PSO-GRNN)的故障诊断方法。将交叉验证得到的平均均方误差作为粒子群的适应度函数,运用粒子群算法搜寻最优的GRNN光滑因子,建立最优的故障诊断模型。结果表明:采用PSO-GRNN模型可实现直升机旋翼不平衡的类型和程度的有效诊断,故障类型准确率高达94.29%,故障程度的诊断最大误差仅6.54%,满足工程需求。

  2. Phosphoinositide 5- and 3-phosphatase activities of a voltage-sensing phosphatase in living cells show identical voltage dependence.

    Science.gov (United States)

    Keum, Dongil; Kruse, Martin; Kim, Dong-Il; Hille, Bertil; Suh, Byung-Chang

    2016-06-28

    Voltage-sensing phosphatases (VSPs) are homologs of phosphatase and tensin homolog (PTEN), a phosphatidylinositol 3,4-bisphosphate [PI(3,4)P2] and phosphatidylinositol 3,4,5-trisphosphate [PI(3,4,5)P3] 3-phosphatase. However, VSPs have a wider range of substrates, cleaving 3-phosphate from PI(3,4)P2 and probably PI(3,4,5)P3 as well as 5-phosphate from phosphatidylinositol 4,5-bisphosphate [PI(4,5)P2] and PI(3,4,5)P3 in response to membrane depolarization. Recent proposals say these reactions have differing voltage dependence. Using Förster resonance energy transfer probes specific for different PIs in living cells with zebrafish VSP, we quantitate both voltage-dependent 5- and 3-phosphatase subreactions against endogenous substrates. These activities become apparent with different voltage thresholds, voltage sensitivities, and catalytic rates. As an analytical tool, we refine a kinetic model that includes the endogenous pools of phosphoinositides, endogenous phosphatase and kinase reactions connecting them, and four exogenous voltage-dependent 5- and 3-phosphatase subreactions of VSP. We show that apparent voltage threshold differences for seeing effects of the 5- and 3-phosphatase activities in cells are not due to different intrinsic voltage dependence of these reactions. Rather, the reactions have a common voltage dependence, and apparent differences arise only because each VSP subreaction has a different absolute catalytic rate that begins to surpass the respective endogenous enzyme activities at different voltages. For zebrafish VSP, our modeling revealed that 3-phosphatase activity against PI(3,4,5)P3 is 55-fold slower than 5-phosphatase activity against PI(4,5)P2; thus, PI(4,5)P2 generated more slowly from dephosphorylating PI(3,4,5)P3 might never accumulate. When 5-phosphatase activity was counteracted by coexpression of a phosphatidylinositol 4-phosphate 5-kinase, there was accumulation of PI(4,5)P2 in parallel to PI(3,4,5)P3 dephosphorylation

  3. Analysis of Possibilities to Reduce the Voltages Induced in Multi-circuit and Multi-voltage Overhead Lines

    Directory of Open Access Journals (Sweden)

    Rafał Tarko

    2015-09-01

    Full Text Available This paper presents the issues of electromagnetic interactions in a four-circuit and dual-voltage power line. Such solutions are increasingly used in practice due to difficulties in land acquisition for the construction of new power lines. Lines of this type, however, have some disadvantages, incl. the electromagnetic interactions between the circuits and voltages induced as their consequence. These issues are considered in relation to an existing four-circuit, 110 kV and 15 kV line. Results of the studies of the interaction effects in a real system, and an analysis of selected ways to reduce the voltage induced in 15 kV line circuits are presented.

  4. Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    DEFF Research Database (Denmark)

    Coppo, Massimiliano; Turri, Roberto; Marinelli, Mattia

    2014-01-01

    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis...

  5. Estimating Voltage Asymmetry Making by One Phase Micro-generator in Low Voltage Network

    Directory of Open Access Journals (Sweden)

    Marian Sobierajski

    2014-12-01

    Full Text Available Connection of one phase micro-generator to the low voltage network increases voltage asymmetry. The voltage asymmetry is defined as the quotient of negative and positive voltage components. The mathematical background of exact and rough computation of the asymmetry quotient is presented in the paper. Considerations are illustrated by simple examples.

  6. 76 FR 70721 - Voltage Coordination on High Voltage Grids; Notice of Staff Workshop

    Science.gov (United States)

    2011-11-15

    ... Energy Regulatory Commission Voltage Coordination on High Voltage Grids; Notice of Staff Workshop Take notice that the Federal Energy Regulatory Commission will hold a Workshop on Voltage Coordination on High Voltage Grids on Thursday, December 1, 2011 from 9 a.m. to 4:30 p.m. This staff-led workshop will be...

  7. Improving transition voltage spectroscopy of molecular junctions

    DEFF Research Database (Denmark)

    Markussen, Troels; Chen, Jingzhe; Thygesen, Kristian Sommer

    2011-01-01

    Transition voltage spectroscopy (TVS) is a promising spectroscopic tool for molecular junctions. The principles in TVS is to find the minimum on a Fowler-Nordheim plot where ln(I/V2) is plotted against 1/V and relate the voltage at the minimum Vmin to the closest molecular level. Importantly, Vmin...... is approximately half the voltage required to see a peak in the dI/dV curve. Information about the molecular level position can thus be obtained at relatively low voltages. In this work we show that the molecular level position can be determined at even lower voltages, Vmin(α), by finding the minimum of ln...

  8. Piezo Voltage Controlled Planar Hall Effect Devices

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K. W.; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  9. Piezo Voltage Controlled Planar Hall Effect Devices.

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K W; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-22

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  10. Capacitor Voltages Measurement and Balancing in Flying Capacitor Multilevel Converters Utilizing a Single Voltage Sensor

    DEFF Research Database (Denmark)

    Farivar, Glen; Ghias, Amer M. Y. M.; Hredzak, Branislav

    2017-01-01

    This paper proposes a new method for measuring capacitor voltages in multilevel flying capacitor (FC) converters that requires only one voltage sensor per phase leg. Multiple dc voltage sensors traditionally used to measure the capacitor voltages are replaced with a single voltage sensor at the ac...... side of the phase leg. The proposed method is subsequently used to balance the capacitor voltages using only the measured ac voltage. The operation of the proposed measurement and balancing method is independent of the number of the converter levels. Experimental results presented for a five-level FC...

  11. Voltage-Sensitive Load Controllers for Voltage Regulation and Increased Load Factor in Distribution Systems

    DEFF Research Database (Denmark)

    Douglass, Philip James; Garcia-Valle, Rodrigo; Østergaard, Jacob

    2014-01-01

    consumption which can be mapped to temperature setpoint offsets of thermostat controlled loads. In networks where a lower voltage level corresponds to high system load (and vice versa), this controller acts to regulate voltage and increase the load factor. Simulations are conducted on low- and medium-voltage......This paper presents a novel controller design for controlling appliances based on local measurements of voltage. The controller finds the normalized voltage deviation accounting for the sensitivity of voltage measurements to appliance state. The controller produces a signal indicating desired power...... distribution systems with residential loads including voltage-sensitive water heaters. In low-voltage systems, the results of the simulations show the controller to be effective at reducing the extremes of voltage and increasing the load factor while respecting end-use temperature constraints. In medium-voltage...

  12. Voltage-controlled photonic oscillator.

    Science.gov (United States)

    Savchenkov, A A; Ilchenko, V S; Liang, W; Eliyahu, D; Matsko, A B; Seidel, D; Maleki, L

    2010-05-15

    We report the development and demonstration of an X-band voltage-controlled photonic oscillator based on a whispering gallery mode resonator made of an electro-optic crystalline material. The oscillator has good spectral purity and wide, agile, linear tunability. We have modified the existing theoretical model of the opto-electronic oscillator to describe the performance of our tunable oscillator and have found a good agreement between the theoretical predictions and the measurement results. We show that the device is promising for higher-frequency applications where high-performance tunable oscillators with wide tunability do not exist.

  13. The influence of low voltage discharges on structure and phase transformations of metallic foils

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    @@ A low voltage electrospark processing of materials allows one to modify the chemical composition and structure of metal layers due to thermo-mechanical influence of discharges and transfer of materials from one electrode to another.

  14. The influence of low voltage discharges on structure and phase transformations of metallic foils

    Institute of Scientific and Technical Information of China (English)

    Pyachin; S.; A.; Verkhoturov; A.; D.; Zavodinsky; V.; G.; Pugachevsky; M.; A.

    2005-01-01

    A low voltage electrospark processing of materials allows one to modify the chemical composition and structure of metal layers due to thermo-mechanical influence of discharges and transfer of materials from one electrode to another.……

  15. Modulation of voltage-gated sodium channels hyperpolarizes the voltage threshold for activation in spinal motoneurones.

    Science.gov (United States)

    Power, Kevin E; Carlin, Kevin P; Fedirchuk, Brent

    2012-03-01

    Previous work has shown that motoneurone excitability is enhanced by a hyperpolarization of the membrane potential at which an action potential is initiated (V(th)) at the onset, and throughout brainstem-evoked fictive locomotion in the adult decerebrate cat and neonatal rat. Modeling work has suggested the modulation of Na(+) conductance as a putative mechanism underlying this state-dependent change in excitability. This study sought to determine whether modulation of voltage-gated sodium channels could induce V(th) hyperpolarization. Whole-cell patch-clamp recordings were made from antidromically identified lumbar spinal motoneurones in an isolated neonatal rat spinal cord preparation. Recordings were made with and without the bath application of veratridine, a plant alkaloid neurotoxin that acts as a sodium channel modulator. As seen in HEK 293 cells expressing Nav1.2 channels, veratridine-modified channels demonstrated a hyperpolarizing shift in their voltage-dependence of activation and a slowing of inactivation that resulted in an enhanced inward current in response to voltage ramp stimulations. In the native rat motoneurones, veratridine-modified sodium channels induced a hyperpolarization of V(th) in all 29 neonatal rat motoneurones examined (mean hyperpolarization: -6.6 ± 4.3 mV). V(th) hyperpolarization was not due to the effects on Ca(2+) and/or K(+) channels as blockade of these currents did not alter V(th). Veratridine also significantly increased the amplitude of persistent inward currents (PICs; mean increase: 72.5 ± 98.5 pA) evoked in response to slow depolarizing current ramps. However, the enhancement of the PIC amplitude had a slower time course than the hyperpolarization of V(th), and the PIC onset voltage could be either depolarized or hyperpolarized, suggesting that PIC facilitation did not mediate the V(th) hyperpolarization. We therefore suggest that central neuronal circuitry in mammals could affect V(th) in a mechanism similar to that of

  16. Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    OpenAIRE

    Coppo, Massimiliano; Turri, Roberto; Marinelli, Mattia; Han, Xue

    2014-01-01

    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis. The load profiles are characterized by using single phase measurement data on voltages, currents and active powers with a 10 minutes resolution. Different scenarios are considered: no tap action, th...

  17. 变电站电容器组不平衡电压值的探讨%Discussion on Magnitude of Unbalanced Voltage of Capacitor Bank in Substations

    Institute of Scientific and Technical Information of China (English)

    黄志华; 唐明; 沈竹; 刘莹

    2013-01-01

    针对一次电容器组差压保护带负荷试验的异常情况,从电容器不平衡电压保护的基本原理入手,通过对比分析整定计算工程应用公式和一次系统设备参数的对应关系,对可能造成电容器差压保护误动、误整定的异常情况进行了详细分析,结合工作实际提出了加强电容器组不平衡电压保护运维管理工作的建议。%Aiming at the abnormal circumstance of load test on differential protection of capacitor bank, the paper starts from the basic principle of unbalance voltage protection and conducts a detailed analysis on ab-normalities that potentially cause maloperation and missetting of differential pressure protection of the capaci-tor by comparing and analyzing the coincidence relation between setting and calculation of technical applica-tion formula and parameters of primary system equipment. The paper finally suggests strengthening the opera-tion and maintenance of unbalanced voltage protection of capacitor bank combining the work practice.

  18. 49 CFR 236.551 - Power supply voltage; requirement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Power supply voltage; requirement. 236.551 Section... supply voltage; requirement. The voltage of power supply shall be maintained within 10 percent of rated voltage....

  19. Voltage holding optimization of the MITICA electrostatic accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Pilan, N., E-mail: nicola.pilan@igi.cnr.it [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Bettini, P. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); DII, Università di Padova, v. Gradenigo 6/A, I-35131 Padova (Italy); De Lorenzi, A. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Specogna, R. [DIEGM, Università di Udine, v. delle Scienze 208, I-33100 Udine (Italy)

    2013-10-15

    Highlights: ► A set of electrostatic analyses of the region surrounding the MITICA electrostatic accelerator has been carried out. ► The distribution of the breakdown probability of the system has been calculated. ► The analyses have allowed identifying the weak point of the system to address the future design optimizations. -- Abstract: Two Heating Neutral Beam Injectors (H-NBI) are planned to be installed in ITER with a total delivered heating power of 33 MW [1]. The main parameters are: 870 kV acceleration voltage with 46 A beam current for hydrogen beam, and 1 MV voltage with 40 A current for deuterium beam. The voltage holding in the 1 MV ITER Neutral Beam Accelerator is recognized to be one of the most critical issues for long pulse (3600 s) beam operation, due to the complex electrostatic structure formed by electrodes polarized at different potentials immersed in vacuum or low-pressure gas. As a matter of fact, the system shall work in a p × d range at the left of the Paschen curve where the classical Townsend breakdown criterion is no longer valid. The voltage holding is governed by the mechanism of the long gap insulation in high vacuum, not yet well consolidated from the physical point of view. This paper is aimed to describe the optimization of the voltage holding capability for MITICA electrostatic accelerator. The results of this analysis will constitute the input for the probabilistic model [3] which is adopted to predict the breakdown probability by means of 2D analyses of the multi electrode – multi voltage system.

  20. Current-voltage characteristics of carbon nanotubes with substitutional nitrogen

    DEFF Research Database (Denmark)

    Kaun, C.C.; Larade, B.; Mehrez, H.;

    2002-01-01

    We report ab initio analysis of current-voltage (I-V) characteristics of carbon nanotubes with nitrogen substitution doping. For zigzag semiconducting tubes, doping with a single N impurity increases current flow and, for small radii tubes, narrows the current gap. Doping a N impurity per nanotube...... unit cell generates a metallic transport behavior. Nonlinear I-V characteristics set in at high bias and a negative differential resistance region is observed for the doped tubes. These behaviors can be well understood from the alignment/mis-alignment of the current carrying bands in the nanotube leads...... due to the applied bias voltage. For a armchair metallic nanotube, a reduction of current is observed with substitutional doping due to elastic backscattering by the impurity....

  1. High voltage load resistor array

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  2. Voltage-Controlled Floating Resistor Using DDCC

    Directory of Open Access Journals (Sweden)

    M. Kumngern

    2011-04-01

    Full Text Available This paper presents a new simple configuration to realize the voltage-controlled floating resistor, which is suitable for integrated circuit implementation. The proposed resistor is composed of three main components: MOS transistor operating in the non-saturation region, DDCC, and MOS voltage divider. The MOS transistor operating in the non-saturation region is used to configure a floating linear resistor. The DDCC and the MOS transistor voltage divider are used for canceling the nonlinear component term of MOS transistor in the non-saturation region to obtain a linear current/voltage relationship. The DDCC is employed to provide a simple summer of the circuit. This circuit offers an ease for realizing the voltage divider circuit and the temperature effect that includes in term of threshold voltage can be compensated. The proposed configuration employs only 16 MOS transistors. The performances of the proposed circuit are simulated with PSPICE to confirm the presented theory.

  3. A New Coordinated Voltage Control Scheme for Offshore AC Grid of HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Cutululis, Nicolaos Antonio; Rather, Zakir Hussain;

    2015-01-01

    This paper proposes a coordinated voltage control scheme (CVCS) which enhances the voltage ride through (VRT) capability of an offshore AC grid comprised of a cluster of offshore wind power plants (WPP) connected through AC cables to the offshore voltage source converter based high voltage DC (VSC-HVDC......) converter station. Due to limited short circuit power contribution from power electronic interfaced variable speed wind generators and with the onshore main grid decoupled by the HVDC link, the offshore AC grid becomes more vulnerable to dynamic voltage events. Therefore, a short circuit fault...... in the offshore AC Grid is likely to have significant implications on the voltage of the offshore AC grid, hence on the power flow to the onshore mainland grid. The proposed CVCS integrates individual local reactive power control of wind turbines and of the HVDC converter with the secondary voltage controller...

  4. Programable Driver for Voltage-Controlled Oscillators

    Science.gov (United States)

    Fowler, L. E.; Mcneil, J. A.

    1985-01-01

    Electronically programable read-only memory (EPROM) and digital-to-analog converter provide customized time-varying voltage for frequency modulation. Voltage used to modulate IMPATT oscillator that serves as microwave pump for solid-state maser in low-noise amplifier. EPROM simple to tailor voltage waveform to suit characteristics of given maser. Digital information for waveform programed into EPROM chip; digital-to-analog converter reads information and produces corresponding analog wave. Principle readily adapted to other applications.

  5. Generator of ultrashort megavolt voltage pulses

    CERN Document Server

    Zheltov, K A; Shalimanov, V F

    2002-01-01

    Paper describes approx 3 ns duration and > 1 MW amplitude voltage pulse generator under high-ohmic (approx 450 Ohm) load. Generator comprises pulse transformer with magnetized core, as well as, resonance tuned circuit of high-voltage solenoid and accumulating spaces of a shaping line containing, moreover, spark gap to switch charge in transmitting line. Paper contains the results of voltage measuring in generator basic units

  6. Investigation of pulsed voltage limiters characteristics

    Directory of Open Access Journals (Sweden)

    Karimov A. V.

    2012-06-01

    Full Text Available A new method for measuring the voltage limit is offered. It has been designed to measure high-power pulsed current of voltage limiters. The error of this method is half as much as the error of the known method of direct measurement. The investigation of dependence of power capability of single-crystal and double-crystal voltage limiters and of the pulsed operation time on pulse duration.

  7. Low-Voltage Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Bidari, E.; Keskin, M.; Maloberti, F.

    1999-01-01

    Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications.......Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications....

  8. Characterisation of the VELO High Voltage System

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L

    2008-01-01

    The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; vercation of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence th...

  9. Characterisation of the VELO High Voltage System

    CERN Document Server

    Rakotomiaramanana, B; Parkes, C; Eklund, L

    2008-01-01

    The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; verification of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence...

  10. Microprocessor-controlled, programmable ramp voltage generator

    Energy Technology Data Exchange (ETDEWEB)

    Hopwood, J.

    1978-11-01

    A special-purpose voltage generator has been developed for driving the quadrupole mass filter of a residual gas analyzer. The generator is microprocessor-controlled with desired ramping parameters programmed by setting front-panel digital thumb switches. The start voltage, stop voltage, and time of each excursion are selectable. A maximum of five start-stop levels may be pre-selected for each program. The ramp voltage is 0 to 10 volts with sweep times from 0.1 to 999.99 seconds.

  11. Magnetoelectric voltage coefficients of magnetoelectric composites

    Institute of Scientific and Technical Information of China (English)

    WAN Yong-ping; ZHONG Zheng; QIU Jin-hao

    2006-01-01

    The magnetoelectric(ME) effect of the particulate magnetostrictive/piezoelectric composite was theoretically studied. The dependence of the ME voltage coefficients on the material properties of the magnetostrictive phase was discussed. The permittivity,permeability and the elastic modulus of the magnetostrictive phase generally have obvious influences on the ME voltage coefficients. The magnetostrictive phase with a large permittivity,large permeability or stiffer modulus will respectively contribute to the higher ME voltage coefficients. For a certain kind of piezoelectric matrix,the ME voltage coefficients can be improved to some extent by choosing those magnetostrictive materials with large permittivity,permeability or high elastic modulus.

  12. Maximum permissible voltage of YBCO coated conductors

    Energy Technology Data Exchange (ETDEWEB)

    Wen, J.; Lin, B.; Sheng, J.; Xu, J.; Jin, Z. [Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China); Hong, Z., E-mail: zhiyong.hong@sjtu.edu.cn [Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China); Wang, D.; Zhou, H.; Shen, X.; Shen, C. [Qingpu Power Supply Company, State Grid Shanghai Municipal Electric Power Company, Shanghai (China)

    2014-06-15

    Highlights: • We examine three kinds of tapes’ maximum permissible voltage. • We examine the relationship between quenching duration and maximum permissible voltage. • Continuous I{sub c} degradations under repetitive quenching where tapes reaching maximum permissible voltage. • The relationship between maximum permissible voltage and resistance, temperature. - Abstract: Superconducting fault current limiter (SFCL) could reduce short circuit currents in electrical power system. One of the most important thing in developing SFCL is to find out the maximum permissible voltage of each limiting element. The maximum permissible voltage is defined as the maximum voltage per unit length at which the YBCO coated conductors (CC) do not suffer from critical current (I{sub c}) degradation or burnout. In this research, the time of quenching process is changed and voltage is raised until the I{sub c} degradation or burnout happens. YBCO coated conductors test in the experiment are from American superconductor (AMSC) and Shanghai Jiao Tong University (SJTU). Along with the quenching duration increasing, the maximum permissible voltage of CC decreases. When quenching duration is 100 ms, the maximum permissible of SJTU CC, 12 mm AMSC CC and 4 mm AMSC CC are 0.72 V/cm, 0.52 V/cm and 1.2 V/cm respectively. Based on the results of samples, the whole length of CCs used in the design of a SFCL can be determined.

  13. Inductive voltage divider modeling in Matlab

    Science.gov (United States)

    Andreev, S. A.; Kim, V. L.

    2017-01-01

    Inductive voltage dividers have the most appropriate metrological characteristics on alternative current and are widely used for converting physical signals. The model of a double-decade inductive voltage divider was designed with the help of Matlab/Simulink. The first decade is an inductive voltage divider with balanced winding, the second decade is a single-stage inductive voltage divider. In the paper, a new transfer function algorithm was given. The study shows errors and differences that appeared between the third degree reduced model and a twenty degree unreduced model. The obtained results of amplitude error differ no more than by 7 % between the reduced and unreduced model.

  14. Development of a voltage scanner of chopper

    CERN Document Server

    Shen Guan Ren; LiShengLi; WangQuanXing; Wu Long Cheng

    2001-01-01

    Development of voltage sweeper of chopper with CPNG are introduced. Voltage sweeper is one of important key parts of chopper. Two years working prove that it is stable and reliable. Its main technology performance save: sine wave frequency: 750 kHz +- 20 Hz; total distortion: 65 Db; output voltage (V-V): 0->=4000 V; the error7 W; voltage supply: 220V AC +-10%, 50 +- 1 Hz; total power supply: <100W; Work temperature range: 0 - 40 degree; Stability in long time <=1%

  15. Congestion management considering voltage security of power systems

    Energy Technology Data Exchange (ETDEWEB)

    Esmaili, Masoud; Shayanfar, Heidar Ali [Centre of Excellence for Power System Automation and Operation, Iran Univ. of Science and Technology, Tehran (Iran); Amjady, Nima [Dept. of Electrical Engineering, Semnan Univ., Semnan (Iran)

    2009-10-15

    Congestion in a power network is turned up due to system operating limits. To relieve congestion in a deregulated power market, the system operator pays to market participants, GENCOs and DISCOs, to alter their active powers considering their bids. After performing congestion management, the network may be operated with a low security level because of hitting some flows their upper limit and some voltages their lower limit. In this paper, a novel congestion management method based on the voltage stability margin sensitivities is introduced. Using the proposed method, the system operator so alleviates the congestion that the network can more retain its security. The proposed method not only makes the system more secure after congestion management than other methods already presented for this purpose but also its cost of providing security is lower than the earlier methods. Test results of the proposed method along with the earlier ones on the New-England test system elaborate the efficiency of the proposed method from the viewpoint of providing a better voltage stability margin and voltage profile as well as a lower security cost. (author)

  16. Excitation of voltage oscillations in an induction voltage adder

    Directory of Open Access Journals (Sweden)

    Nichelle Bruner

    2009-07-01

    Full Text Available The induction voltage adder is an accelerator architecture used in recent designs of pulsed-power driven x-ray radiographic systems such as Sandia National Laboratories’ Radiographic Integrated Test Stand (RITS, the Atomic Weapons Establishment’s planned Hydrus Facility, and the Naval Research Laboratory’s Mercury. Each of these designs relies on magnetic insulation to prevent electron loss across the anode-cathode gap in the vicinity of the adder as well as in the coaxial transmission line. Particle-in-cell simulations of the RITS adder and transmission line show that, as magnetic insulation is being established during a pulse, some electron loss occurs across the gap. Sufficient delay in the cavity pulse timings provides an opportunity for high-momentum electrons to deeply penetrate the cavities of the adder cells where they can excite radio-frequency resonances. These oscillations may be amplified in subsequent gaps, resulting in oscillations in the output power. The specific modes supported by the RITS-6 accelerator and details of the mechanism by which they are excited are presented in this paper.

  17. Smart Demand for Improving Short-term Voltage Control on Distribution Networks

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; P. Da Silva, Luiz C.; Xu, Zhao

    2009-01-01

    customer integration to aid power system performance is almost inevitable. This study introduces a new type of smart demand side technology, denoted demand as voltage controlled reserve (DVR), to improve short-term voltage control, where customers are expected to play a more dynamic role to improve voltage...... control. The technology can be provided by thermostatically controlled loads as well as other types of load. This technology is proven to be effective in case of distribution systems with a large composition of induction motors, where the voltage presents a slow recovery characteristic due to deceleration...... of the motors during faults. This study presents detailed models, discussion and simulation tests to demonstrate the technical viability and effectiveness of the DVR technology for short-term voltage control....

  18. Optimized Controller Design for a 12-Pulse Voltage Source Converter Based HVDC System

    Science.gov (United States)

    Agarwal, Ruchi; Singh, Sanjeev

    2017-08-01

    The paper proposes an optimized controller design scheme for power quality improvement in 12-pulse voltage source converter based high voltage direct current system. The proposed scheme is hybrid combination of golden section search and successive linear search method. The paper aims at reduction of current sensor and optimization of controller. The voltage and current controller parameters are selected for optimization due to its impact on power quality. The proposed algorithm for controller optimizes the objective function which is composed of current harmonic distortion, power factor, and DC voltage ripples. The detailed designs and modeling of the complete system are discussed and its simulation is carried out in MATLAB-Simulink environment. The obtained results are presented to demonstrate the effectiveness of the proposed scheme under different transient conditions such as load perturbation, non-linear load condition, voltage sag condition, and tapped load fault under one phase open condition at both points-of-common coupling.

  19. Effect of anodizing voltage on the sorption of water molecules on porous alumina

    Energy Technology Data Exchange (ETDEWEB)

    Vrublevsky, I., E-mail: vrublevsky@bsuir.edu.by [Belarusian State University of Informatics and Radioelectronics, Department of Micro and Nanoelectronics, 220013 Minsk (Belarus); Chernyakova, K. [Belarusian State University of Informatics and Radioelectronics, Department of Micro and Nanoelectronics, 220013 Minsk (Belarus); Bund, A.; Ispas, A.; Schmidt, U. [Fachgebiet Elektrochemie und Galvanotechnik, Technische Universitaet Ilmenau, 98693 Ilmenau (Germany)

    2012-05-01

    The amount of water adsorbed on different centers on the surface of oxalic acid alumina films is a function of the anodizing voltage. It is decreased with increasing the anodizing voltage from 20 up to 50 V, came up to maximum value at 20-30 V and slightly increased at voltages above 50 V. Water adsorption by oxide films formed at voltages below 50 V can be due to the negative surface charge that is present on the alumina surface. The negative surface charge disappears in the films formed at voltages higher than 50 V, and thus, the water is adsorbed on aluminum ions in a tetrahedral and octahedral environment. The correlation between anodizing conditions of aluminum in oxalic acid and the structure and composition of anodic alumina was established by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM), thermogravimetric and differential thermal analyses (TG/DTA).

  20. Switchable voltage control of the magnetic coercive field via magnetoelectric effect

    Science.gov (United States)

    Wang, Jing; Ma, Jing; Li, Zheng; Shen, Yang; Lin, Yuanhua; Nan, C. W.

    2011-08-01

    Switchable voltage modulation of the magnetic properties is reported in different multiferroic bilayers with magnetic films grown on pre-poled ferroelectric substrates, based on the magneto-optical Kerr effect observations. The dynamic voltage control of the magnetic coercive field (Hc) is dependent not only on the materials properties of each ferroic layer, but also on the bias voltage history. The Hc versus electric field behaviors essentially track the dependence of the piezostrains of the substrates on the bias voltage. The observations demonstrate that Hc in such multiferroic bilayers can be controlled by voltage via strain-mediated magnetoelectric coupling and that the Hc change is not an artifact due to a heating effect.

  1. Development of a Simplified Calculation Tool for Voltage Drop caused by Transformer Inrush in Distribution System

    Science.gov (United States)

    Nakachi, Yoshiki; Fukae, Takayuki; Sugahara, Toshinori; Nakamura, Hayato; Koyama, Mitsuaki; Ueda, Fukashi

    It is well known that the voltage drop due to the inrush current at energizing transformer, may at times, interrupt electrical equipment. Generally, the voltage drop is calculated by using the sophisticated tool such as EMTP, so the transformer saturation phenomenon has been properly represented. However, it is not practical for distribution system engineers to calculate the voltage drop with transformer inrush by using EMTP, because there are a lot of network access requests needing such calculations with many kinds of transformers. Therefore, in this paper, a simplified and easy-to-use calculation tool for voltage drop caused by transformer inrush in distribution system is developed. In order to grasp the voltage drop by inrush current during the planning stage, it is formulated by considering the transformer saturation/unsaturation periods in each winding type, the developed tool is based on the versatile spreadsheet software such as Microsoft Excel®. It can be used with accuracy almost similar to the EMTP.

  2. High voltage generator circuit with low power and high efficiency applied in EEPROM

    Institute of Scientific and Technical Information of China (English)

    Liu Yan; Zhang Shilin; Zhao Yiqiang

    2012-01-01

    This paper presents a low power and high efficiency high voltage generator circuit embedded in electrically erasable programmable read-only memory (EEPROM).The low power is minimized by a capacitance divider circuit and a regulator circuit using the controlling clock switch technique.The high efficiency is dependent on the zero threshold voltage (Vth) MOSFET and the charge transfer switch (CTS) charge pump.The proposed high voltage generator circuit has been implemented in a 0.35μm EEPROM CMOS process.Measured results show that the proposed high voltage generator circuit has a low power consumption of about 150.48 μW and a higher pumping efficiency (83.3%) than previously reported circuits.This high voltage generator circuit can also be widely used in low-power flash devices due to its high efficiency and low power dissipation.

  3. Low voltage driven dielectric electro active polymer actuator with integrated piezoelectric transformer based driver

    DEFF Research Database (Denmark)

    Andersen, Thomas; Rødgaard, Martin Schøler; Thomsen, Ole Cornelius

    2011-01-01

    Today’s Dielectric Electro Active Polymer (DEAP) actuators utilize high voltage (HV) in the range of kilo volts to fully stress the actuator. The requirement of HV is a drawback for the general use in the industry due to safety concerns and HV regulations. In order to avoid the HV interface to DEAP...... actuators, a low voltage solution is developed by integrating the driver electronic into a 110 mm tall cylindrical coreless Push InLastor actuator. To decrease the size of the driver, a piezoelectric transformer (PT) based solution is utilized. The PT is essentially an improved Rosen type PT...... with interleaved sections. Furthermore, the PT is optimized for an input voltage of 24 V with a gain high enough to achieve a DEAP voltage of 2.5 kV. The PT is simulated and verified through measurements on a working prototype. With the adapted hysteretic based control system; output voltage wave forms of both...

  4. Variable polarity LMS feedback based on displacement nulling to compensate unbalance of magnetic bearing%基于最小位移的磁悬浮转子变极性LMS反馈不平衡补偿

    Institute of Scientific and Technical Information of China (English)

    宋腾; 韩邦成; 郑世强; 冯锐

    2015-01-01

    In consideration of the decrease of high-speed motor magnetic rotor displacement accuracy generated by unbalance vibration,a LMS feedback algorithm based on the principle of displacement nulling was proposed.The generalized dynamic stiffness of the system was improved by online identifying the same-frequency component in displacment signal and adding feedback to achieve unbalance compensation.In addition,the stability of close loop system was analyzed by use of generalized root locus;meanwhile, to cross over the critical frequency and achieve the displacement compensation within the whole speed range,a variable polarity strategy was raised.The experiment results demonstrate the method can suppress the displacement same-frequency vibration effectively within the whole speed range.%针对高速电机磁悬浮转子受不平衡扰动时位移精度下降的问题,提出一种基于最小位移原则的变极性最小均方误差(least mean square,LMS)反馈不平衡补偿策略,通过在线辨识位移信号中的转速同频分量,引入反馈补偿来增加系统对同频分量的广义动刚度,实现不平衡补偿。利用广义根轨迹分析了引入补偿后系统的闭环稳定性,同时针对仅以负极性或正极性引入补偿后,闭环系统均存在临界转频以上或以下发散的问题,设计了通过切换引入补偿的极性来穿越临界转频,从而实现引入LMS反馈补偿后全转速范围闭环稳定。实验结果表明,该方法在全转速范围内均能大幅减小位移信号中的转速同频分量。

  5. A Synchrophasor Based Optimal Voltage Control Scheme with Successive Voltage Stability Margin Improvement

    Directory of Open Access Journals (Sweden)

    Heng-Yi Su

    2016-01-01

    Full Text Available This paper proposes an optimal control scheme based on a synchronized phasor (synchrophasor for power system secondary voltage control. The framework covers voltage stability monitoring and control. Specifically, a voltage stability margin estimation algorithm is developed and built in the newly designed adaptive secondary voltage control (ASVC method to achieve more reliable and efficient voltage regulation in power systems. This new approach is applied to improve voltage profile across the entire power grid by an optimized plan for VAR (reactive power sources allocation; therefore, voltage stability margin of a power system can be increased to reduce the risk of voltage collapse. An extensive simulation study on the IEEE 30-bus test system is carried out to demonstrate the feasibility and effectiveness of the proposed scheme.

  6. Evaluation of the Voltage Support Strategies for the Low Voltage Grid Connected PV

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2010-01-01

    PVs. In order to increase PV penetration level further, new voltage support control functions for individual inverters are required. This paper investigates distributed reactive power regulation and active power curtailment strategies regarding the development of PV connection capacity by evaluation......Admissible range of grid voltage is one of the strictest constraints for the penetration of distributed photovoltaic (PV) generators especially connection to low voltage (LV) public networks. Voltage limits are usually fulfilled either by network reinforcements or limiting of power injections from...

  7. 高等院校英语教育专业性别失衡现象分析——以N学院教育学院为例%Analysis of the Unbalance of Sex Proportion in English Education Speciality in College

    Institute of Scientific and Technical Information of China (English)

    余爽爽

    2015-01-01

    This paper takes the example of Education School of N College to analyze the serious unbalance of sex proportion in Eng-lish education Specialty in College and its negative influence. Besides, the reasons of this unbalance and how to change it is dis-cussed.%以N学院教育学院为例来分析我国高校英语教育专业性别比例的严重失衡的现象以及所造成的负面影响,阐述造成这种失衡的原因,并对如何改变这种失衡现象做一些有益的探索.

  8. Influence of current limitation on voltage stability with voltage sourced converter HVDC

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Jóhannsson, Hjörtur; Hansen, Anca Daniela;

    2013-01-01

    A first study of voltage stability with relevant amount of Voltage Sourced Converter based High Voltage Direct Current (VSC-HVDC) transmission is presented, with particular focus on the converters’ behaviour when reaching their rated current. The detrimental effect of entering the current...

  9. Voltage stability in low voltage microgrids in aspects of active and reactive power demand

    Directory of Open Access Journals (Sweden)

    Parol Mirosław

    2016-03-01

    Full Text Available Low voltage microgrids are autonomous subsystems, in which generation, storage and power and electrical energy consumption appear. In the paper the main attention has been paid to the voltage stability issue in low voltage microgrid for different variants of its operation. In the introduction a notion of microgrid has been presented, and also the issue of influence of active and reactive power balance on node voltage level has been described. Then description of voltage stability issue has been presented. The conditions of voltage stability and indicators used to determine voltage stability margin in the microgrid have been described. Description of the low voltage test microgrid, as well as research methodology along with definition of considered variants of its operation have been presented further. The results of exemplary calculations carried out for the daily changes in node load of the active and reactive power, i.e. the voltage and the voltage stability margin indexes in nodes have been presented. Furthermore, the changes of voltage stability margin indexes depending on the variant of the microgrid operation have been presented. Summary and formulation of conclusions related to the issue of voltage stability in microgrids have been included at the end of the paper.

  10. Reduced Voltage Scaling in Clock Distribution Networks

    Directory of Open Access Journals (Sweden)

    Khader Mohammad

    2009-01-01

    Full Text Available We propose a novel circuit technique to generate a reduced voltage swing (RVS signals for active power reduction on main buses and clocks. This is achieved without performance degradation, without extra power supply requirement, and with minimum area overhead. The technique stops the discharge path on the net that is swinging low at a certain voltage value. It reduces active power on the target net by as much as 33% compared to traditional full swing signaling. The logic 0 voltage value is programmable through control bits. If desired, the reduced-swing mode can also be disabled. The approach assumes that the logic 0 voltage value is always less than the threshold voltage of the nMOS receivers, which eliminate the need of the low to high voltage translation. The reduced noise margin and the increased leakage on the receiver transistors using this approach have been addressed through the selective usage of multithreshold voltage (MTV devices and the programmability of the low voltage value.

  11. Low-Voltage Continuous Electrospinning Patterning.

    Science.gov (United States)

    Li, Xia; Li, Zhaoying; Wang, Liyun; Ma, Guokun; Meng, Fanlong; Pritchard, Robyn H; Gill, Elisabeth L; Liu, Ye; Huang, Yan Yan Shery

    2016-11-30

    Electrospinning is a versatile technique for the construction of microfibrous and nanofibrous structures with considerable potential in applications ranging from textile manufacturing to tissue engineering scaffolds. In the simplest form, electrospinning uses a high voltage of tens of thousands volts to draw out ultrafine polymer fibers over a large distance. However, the high voltage limits the flexible combination of material selection, deposition substrate, and control of patterns. Prior studies show that by performing electrospinning with a well-defined "near-field" condition, the operation voltage can be decreased to the kilovolt range, and further enable more precise patterning of fibril structures on a planar surface. In this work, by using solution dependent "initiators", we demonstrate a further lowering of voltage with an ultralow voltage continuous electrospinning patterning (LEP) technique, which reduces the applied voltage threshold to as low as 50 V, simultaneously permitting direct fiber patterning. The versatility of LEP is shown using a wide range of combination of polymer and solvent systems for thermoplastics and biopolymers. Novel functionalities are also incorporated when a low voltage mode is used in place of a high voltage mode, such as direct printing of living bacteria; the construction of suspended single fibers and membrane networks. The LEP technique reported here should open up new avenues in the patterning of bioelements and free-form nano- to microscale fibrous structures.

  12. Modeling and Simulation of Low Voltage Arcs

    NARCIS (Netherlands)

    Ghezzi, L.; Balestrero, A.

    2010-01-01

    Modeling and Simulation of Low Voltage Arcs is an attempt to improve the physical understanding, mathematical modeling and numerical simulation of the electric arcs that are found during current interruptions in low voltage circuit breakers. An empirical description is gained by refined electrical

  13. High-voltage engineering and testing

    CERN Document Server

    Ryan, Hugh M

    2013-01-01

    This 3rd edition of High Voltage Engineering Testing describes strategic developments in the field and reflects on how they can best be managed. All the key components of high voltage and distribution systems are covered including electric power networks, UHV and HV. Distribution systems including HVDC and power electronic systems are also considered.

  14. Modeling and Simulation of Low Voltage Arcs

    NARCIS (Netherlands)

    Ghezzi, L.; Balestrero, A.

    2010-01-01

    Modeling and Simulation of Low Voltage Arcs is an attempt to improve the physical understanding, mathematical modeling and numerical simulation of the electric arcs that are found during current interruptions in low voltage circuit breakers. An empirical description is gained by refined electrical m

  15. Voltage-gated lipid ion channels

    DEFF Research Database (Denmark)

    Blicher, Andreas; Heimburg, Thomas Rainer

    2013-01-01

    Synthetic lipid membranes can display channel-like ion conduction events even in the absence of proteins. We show here that these events are voltage-gated with a quadratic voltage dependence as expected from electrostatic theory of capacitors. To this end, we recorded channel traces and current...

  16. Overcurrent protection issues due to the DG connection

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, J.C.; Tourn, D.H.; Amatti, J.C. [Rio Cuarto National University (IPSEP/UNRC), Cordoba (Argentina). Electric Power Systems Protection Institute], E-mail: jcgomez@ing.unrc.edu.ar

    2009-07-01

    The present energy crisis drives to carry to an extreme the use of all the available energy sources, which need to be connected to the network in their closest point. Traditional electric systems are changing their characteristics, in what concerns to structure, operation, and especially on protection methodologies. The new protection problems of the different parts of the system are explained. The solution presents positive and negative aspects that impact the utility and the customer in different ways. A revision about interconnection international standards is presented. The contributions of generators to short circuit currents is analyzed, especially the double fed generator. Philosophy changes are studied, such as: fault current bi directionality, modification of the protection reach, failures of the overcurrent coordination due to current share, etc. Solicitations to DG due to the normal unbalance of distribution systems are also studied. It is analyzed the discrepancy between the customers and utilities regarding the 'islanding operation', presenting the semi-rigid connection. The changes in the coordination methodology fusible-recloser are also studied, proposing a new methodology to check this coordination. Experimental results on 13.2 kV are presented that relate the deionization without zero current, with arc length and with 'network power to DG power ratio'. It is concluded that DG application offers technical-economic advantages so much to the utility as to the user; and that the technology for these new protection approaches is already available, requiring of investments whose justification needs of a specific analysis for each particular case. (author)

  17. Effects of. gamma. -ray irradiation on residual voltage in polyethylene containing antioxidant

    Energy Technology Data Exchange (ETDEWEB)

    Yamanaka, Sanshiro; Fukuda, Tadashi; Sawa, Goro; Ieda, Masayuki

    1986-12-01

    For providing a non-destructive technique for determining the degree of deterioration in insulating material, an attempt is made to examine the effect of ..gamma..-ray irradiation on the residual voltage in low-density polyethylene containing an antioxidant. A phenol compound (Irganox 1010) or an amine compound (Antage F) is used as antioxidant. It is shown that for non-irradiated material, addition of Antage F increases both the residual voltage (V) and current (I) while the increase in V and I is less at Irganox 1010 concentrations up to about 5 percent. Irradiation of ..gamma..-rays has little influence on the properties of material containing a large concentration of an antioxidant, indicating that the addition of an antioxidant can increase resistance to radiation. Antioxidant has little effect, however, if its content is low. For a sample containing 5% Irganox 1010, an exposure of 41.5 Mrad increases the residual voltage but the increase is linear with time. For a sample containing 5% Antage F, on the other hand, the residual voltage is largely increased above an exposure of 7.3 Mrad, but the time dependence of residual voltage shows a maximum. Analysis is made of the discharge current from material containing a large content of an antioxidant, showing that addition of such an additive has favorable effects. Dependence of residual voltage on applied voltage is analyzed. Results obtained suggest that insulation deterioration due to ..gamma..-ray irradiation can be estimated from measurements of residual voltage. (Nogami, K.).

  18. An ANN Based Capicitor Voltage Balancing Method For Neutral Point Clamped Multi-Level Inverter

    Directory of Open Access Journals (Sweden)

    P.J.S. Praveen,

    2015-11-01

    Full Text Available Multi-level inverters are became popular for usage in medium voltage, low voltage power applications due to flexibility in control and better performance characteristics in terms of harmonic regulation. Neutral point clamped are popular as they require less number of sources as their input when compared with their counter parts i.e. cascaded multi-level inverters and found to be reliable when compared with flying capacitor based multi-level inverters. But when neutral clamped technologies are used for generation of three-phase voltages, the capacitors that are connected at input side experiences imbalance in their voltages, this makes neutral point clamped multi-level inverters less reliable. In the proposed work an attempt is made to study circuits that balances the capacitor voltages and a scheme is investigated for balancing the capacitor voltages. Method proposed in [1] uses PID controller for balancing the capacitor voltages. In this project PI based control scheme and artificial neural network (ANN based control scheme for the front end circuit shown in [1] are designed for achieving balance among the capacitor voltages. The proposed control scheme is simulated with the help of Simpowersystems block set and neural network toolbox of MATLAB software for different load conditions. Results obtained from ANN based controller and PI controller are presented.

  19. Practical considerations in voltage stability assessment

    Energy Technology Data Exchange (ETDEWEB)

    Kundur, P.; Gao, B. [Powertech Labs. Inc., Surrey, BC (Canada)

    1994-12-31

    This paper deals with some of the most important practical issues related to voltage stability assessment of large practical systems. A brief discussion of the practical aspects of voltage stability problem and prevention of voltage instability is given first, followed by descriptions of different analytical techniques and tools for voltage stability analysis. Presentations of analytical tools is focused on the VSTAB program which incorporates the modal analysis, continuation power flow, and shortest distance to instability techniques, Finally, an example case study of a practical large system is presented. The case study illustrates how modal analysis is used to determine the most effective load shedding scheme for preventing voltage instability. (author) 15 refs., 2 figs., 2 tabs.

  20. Radiatively heated high voltage pyroelectric crystal pulser

    Energy Technology Data Exchange (ETDEWEB)

    Antolak, A.J., E-mail: antolak@sandia.gov [Sandia National Laboratories, Livermore, CA 94550 (United States); Chen, A.X. [Sandia National Laboratories, Livermore, CA 94550 (United States); Leung, K.-N. [Sandia National Laboratories, Livermore, CA 94550 (United States); Nuclear Engineering Department, University of California, Berkeley (United States); Morse, D.H.; Raber, T.N. [Sandia National Laboratories, Livermore, CA 94550 (United States)

    2014-01-21

    Thin lithium tantalate pyroelectric crystals in a multi-stage pulser were heated by quartz lamps during their charging phase to generate high voltage pulses. The charging voltage was determined empirically based on the measured breakdown voltage in air and verified by the induced breakdown voltage of an external high voltage power supply. A four-stage pyroelectric crystal device generated pulse discharges of up to 86 kV using both quartz lamps (radiative) and thermoelectric (conductive) heating. Approximately 50 mJ of electrical energy was harvested from the crystals when radiatively heated in air, and up to 720 mJ was produced when the crystals were submerged in a dielectric fluid. It is anticipated that joule-level pulse discharges could be obtained by employing additional stages and optimizing the heating configuration.

  1. Non-contact current and voltage sensor

    Science.gov (United States)

    Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

    2014-03-25

    A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

  2. Voltage-gated lipid ion channels

    DEFF Research Database (Denmark)

    Blicher, Andreas; Heimburg, Thomas Rainer

    2013-01-01

    Synthetic lipid membranes can display channel-like ion conduction events even in the absence of proteins. We show here that these events are voltage-gated with a quadratic voltage dependence as expected from electrostatic theory of capacitors. To this end, we recorded channel traces and current...... histograms in patch-experiments on lipid membranes. We derived a theoretical current-voltage relationship for pores in lipid membranes that describes the experimental data very well when assuming an asymmetric membrane. We determined the equilibrium constant between closed and open state and the open...... probability as a function of voltage. The voltage-dependence of the lipid pores is found comparable to that of protein channels. Lifetime distributions of open and closed events indicate that the channel open distribution does not follow exponential statistics but rather power law behavior for long open times...

  3. Coordinated Voltage Control of Active Distribution Network

    Directory of Open Access Journals (Sweden)

    Xie Jiang

    2016-01-01

    Full Text Available This paper presents a centralized coordinated voltage control method for active distribution network to solve off-limit problem of voltage after incorporation of distributed generation (DG. The proposed method consists of two parts, it coordinated primal-dual interior point method-based voltage regulation schemes of DG reactive powers and capacitors with centralized on-load tap changer (OLTC controlling method which utilizes system’s maximum and minimum voltages, to improve the qualified rate of voltage and reduce the operation numbers of OLTC. The proposed coordination has considered the cost of capacitors. The method is tested using a radial edited IEEE-33 nodes distribution network which is modelled using MATLAB.

  4. Modeling of a breakdown voltage in microdischarges

    Directory of Open Access Journals (Sweden)

    Đorđević Ivana

    2009-01-01

    Full Text Available Non-equilibrium plasmas have been used as one of the principal technologies for development of microelectronics and they are the basis for the development of new generations of nano-electronics devices required for 65 and 40 nm technologies. Microdischarges recently have become more common in everyday life. Technology of plasma etching has enabled us to develop such discharges and the field of microdischarges has grown into the most interesting field of the physics of collisional non-equilibrium plasmas. Recently, an effort to fabricate microplasma sources that can be integrated with other MEMS devices to form larger Microsystems has been made. Plasma-based microsystems can find application in bio-microelectro- mechanical system (bio-MEMS sterilization, small-scale materials processing and microchemical analysis systems. However, integrability requires not only a size reduction, but also an understanding of the physics governing the new small-scale discharges. In this paper, we have performed modeling of a breakdown voltage by using Particle-in-Cell/Monte Carlo collision (PIC/MCC code taking into account the secondary electron emission due to a high field.

  5. Low voltage transmission electron microscopy of graphene.

    Science.gov (United States)

    Bachmatiuk, Alicja; Zhao, Jiong; Gorantla, Sandeep Madhukar; Martinez, Ignacio Guillermo Gonzalez; Wiedermann, Jerzy; Lee, Changgu; Eckert, Juergen; Rummeli, Mark Hermann

    2015-02-04

    The initial isolation of graphene in 2004 spawned massive interest in this two-dimensional pure sp(2) carbon structure due to its incredible electrical, optical, mechanical, and thermal effects. This in turn led to the rapid development of various characterization tools for graphene. Examples include Raman spectroscopy and scanning tunneling microscopy. However, the one tool with the greatest prowess for characterizing and studying graphene is the transmission electron microscope. State-of-the-art (scanning) transmission electron microscopes enable one to image graphene with atomic resolution, and also to conduct various other characterizations simultaneously. The advent of aberration correctors was timely in that it allowed transmission electron microscopes to operate with reduced acceleration voltages, so that damage to graphene is avoided while still providing atomic resolution. In this comprehensive review, a brief introduction is provided to the technical aspects of transmission electron microscopes relevant to graphene. The reader is then introduced to different specimen preparation techniques for graphene. The different characterization approaches in both transmission electron microscopy and scanning transmission electron microscopy are then discussed, along with the different aspects of electron diffraction and electron energy loss spectroscopy. The use of graphene for other electron microscopy approaches such as in-situ investigations is also presented. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Current-voltage characteristics of quantum-point contacts in the closed-channel regime: Transforming the bias voltage into an energy scale

    DEFF Research Database (Denmark)

    Gloos, K.; Utko, P.; Aagesen, M.;

    2006-01-01

    We investigate the I(V) characteristics (current versus bias voltage) of side-gated quantum-point contacts, defined in GaAs/AlxGa1-xAs heterostructures. These point contacts are operated in the closed-channel regime, that is, at fixed gate voltages below zero-bias pinch-off for conductance. Our...... analysis is based on a single scaling factor, extracted from the experimental I(V) characteristics. For both polarities, this scaling factor transforms the change of bias voltage into a change of electron energy. The latter is determined with respect to the top of the potential barrier of the contact....... Such a built-in energy-voltage calibration allows us to distinguish between the different contributions to the electron transport across the pinched-off contact due to thermal activation or quantum tunneling. The first involves the height of the barrier, and the latter also its length. In the model that we...

  7. Hysteresis in voltage-gated channels.

    Science.gov (United States)

    Villalba-Galea, Carlos A

    2016-09-30

    Ion channels constitute a superfamily of membrane proteins found in all living creatures. Their activity allows fast translocation of ions across the plasma membrane down the ion's transmembrane electrochemical gradient, resulting in a difference in electrical potential across the plasma membrane, known as the membrane potential. A group within this superfamily, namely voltage-gated channels, displays activity that is sensitive to the membrane potential. The activity of voltage-gated channels is controlled by the membrane potential, while the membrane potential is changed by these channels' activity. This interplay produces variations in the membrane potential that have evolved into electrical signals in many organisms. These signals are essential for numerous biological processes, including neuronal activity, insulin release, muscle contraction, fertilization and many others. In recent years, the activity of the voltage-gated channels has been observed not to follow a simple relationship with the membrane potential. Instead, it has been shown that the activity of voltage-gated channel displays hysteresis. In fact, a growing number of evidence have demonstrated that the voltage dependence of channel activity is dynamically modulated by activity itself. In spite of the great impact that this property can have on electrical signaling, hysteresis in voltage-gated channels is often overlooked. Addressing this issue, this review provides examples of voltage-gated ion channels displaying hysteretic behavior. Further, this review will discuss how Dynamic Voltage Dependence in voltage-gated channels can have a physiological role in electrical signaling. Furthermore, this review will elaborate on the current thoughts on the mechanism underlying hysteresis in voltage-gated channels.

  8. Modeling of High-voltage Breakdown in Helium

    Science.gov (United States)

    Xu, Liang; Khrabrov, Alexander; Kaganovich, Igor; Sommerer, Timothy

    2016-09-01

    We investigate the breakdown in extremely high reduced electric fields (E/N) between parallel-plate electrodes in helium. The left branch of the Paschen curve in the voltage range of 20-350kV and inter-electrode gap range of 0.5-3.5cm is studied analytically and with Monte-Carlo/PIC simulations. The model incorporates electron, ion, and fast neutral species whose energy-dependent anisotropic scattering, as well as backscattering at the electrodes, is carefully taken into account. Our model demonstrates that (1) anisotropic scattering is indispensable for producing reliable results at such high voltage and (2) due to the heavy species backscattered at cathode, breakdown can occur even without electron- and ion-induced ionization of the background gas. Fast atoms dominate in the breakdown process more and more as the applied voltage is increased, due to their increasing ionization cross-section and to the copious flux of energetic fast atoms generated in charge-exchange collisions.

  9. 西地那非抑制高肺血流肺动脉高压大鼠肺血管重构和上调肺血管Kv1.5mRNA表达%Sildenafil inhibits pulmonary vascular remodeling and up-regulates voltage-gated potassium channel Kv1.5 mRNA expression in secondary pulmonary hypertension due to left-to-right shunt in rats

    Institute of Scientific and Technical Information of China (English)

    胡蕾; 谈林华; 林隆; 何小军; 范佳杰

    2010-01-01

    Objective To investigate the effects of sildenafil on pulmonary vascular remodeling and voltage-gated potassium channeI Kv1.5 mRNA expression of pulmonary vasculature in secondary pulmonary hypertension due to left-to-right shunt in rats.Methods Male twenty-seven SD rats were randomly divided into sham group(n=9),shunt group(n=9)and shunt+sildenafil group(n=9).A left-to-right shunt was established on shunt group and shunt+sildenafil group rats by making fistula between abdominal aorta and inferior vena cava.Rats of the shunt+sildenafil group were administered sildenafil by gastric gavage at a dose of 10 mg·kg-1·d-1;whereas the rats of the sham group and the shunt group were fed with the same amount of saline. Eleven weeks later,mean pulmonary artery pressure(mPAP)and systolic pulmonary artery pressure(sPAP)were measured.The ratio of right ventricular mass to left ventricular plus septal mass[Rv/(LV+S)]was alao calculated and taken as a marker of the severity of right ventricular hypertrophy.The pathological changes of pulmonary vasculature were evaluated by calculating the relative medial thickness(RMT) of middle and small pulmonary muscularized arteries.The voltage-gated potassium channel Kv1.5 mRNA expression of pulmonary vasculature was qnantifieel using real-time PCIL Results Compared with the rats of sham grouD.the rats of shunt group had higher mPAP,sPAP,RV/(LV+S)ratio,and RMT of middie and small pulmonary muscularized(P0.05).Conclusions Sidenafil inhibits pulmonary vascular remodeling and up-regulates Kv1.5 mRNA expression in rats with secondary pulmonary hypertension due to left-to-right shunt.%目的 观察高肺血流肺动脉高压大鼠肺血管结构重建和肺血管电压依从钾通道Kv1.5mRNA表达变化,探讨口服西地那非对高肺血流肺动脉高压大鼠肺血管重构及肺血管电压依从钾通道Kv1.5mRNA表达的影响.方法 将27只雄性SD大鼠随机分为对照组(n=9)、分流组(n=9)、分流+西地那非组(n=9).后两

  10. Circuit Design on Three-phase Current Unbalance of Electric Vehicle Motor Controller%电动汽车用电机控制器三相电流不平衡检测电路设计

    Institute of Scientific and Technical Information of China (English)

    赵圣宝; 吴成加

    2015-01-01

    In order to improve the reliability and stability of the electric vehicle motor controller, the authors design a type of three-phase current unbalance circuit, including the selection of the current sensor, the circuit of three-phase filter, the inverting summing circuit of three-phase current, the comparator circuit of upper and lower limits and the light-emitting diode warning. Through simulation experiments, the results verify the detection circuit is correct and feasible.%为提高电动汽车电机控制器的可靠性和稳定性,设计一种三相电流不平衡检测电路,包括电流传感器选型及电路、三相滤波电路、三相电流反相求和电路,上/下限比较电路及发光二极管报警电路。通过仿真试验,验证该检测电路是正确和可行的。

  11. A novel single phase buck PFC converter in discontinuous capacitor voltage mode operation

    Institute of Scientific and Technical Information of China (English)

    邓超平; 凌志斌; 叶芃生

    2003-01-01

    A novel single-phase Buck converter for power factor correction is proposed. It features simple control due to the constant duty ratio PWM used. It can obtain unity power factor by selecting a suitable LC filter at its input to force the voltage of capacitor to operate in discontinuous capacitor voltage mode. And by using another resonant LC filter at its output, it can not only eliminate the input current distortion at the vicinity of the zero crossing of the supply but also drastically reduce the 100 Hz output voltage ripple. The validity of analysis is confirmed by simulation results and experimental results.

  12. Initial position estimation method for permanent magnet synchronous motor based on improved pulse voltage injection

    DEFF Research Database (Denmark)

    Wang, Z.; Lu, K.; Ye, Y.

    2011-01-01

    According to saliency of permanent magnet synchronous motor (PMSM), the information of rotor position is implied in performance of stator inductances due to the magnetic saturation effect. Researches focused on the initial rotor position estimation of PMSM by injecting modulated pulse voltage...... vectors. The relationship between the inductance variations and voltage vector positions was studied. The inductance variation effect on estimation accuracy was studied as well. An improved five-pulses injection method was proposed, to improve the estimation accuracy by choosing optimaized voltage vectors...

  13. Clustered PV Inverters in LV Networks: An Overview of Impacts and Comparison of Voltage Control Strategies

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus;

    2009-01-01

    and power quality must be maintained or improved by adding cooperative control features to the grid-connected inverters. This paper first gives an overview of bilateral impacts between multiple distributed generations (DG) and grid. Regarding of these impacts, recent advances in static grid voltage support......High penetration of photovoltaic (PV) inverters in low voltage (LV) distribution network challenges the voltage stability due to interaction between multiple inverters and grid. As the main objective is to provide more power injection from VSC-based PV inverters, grid stability, reliability...

  14. Coupling capacitor voltage transformer: A model for electromagnetic transient studies

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, D.; Neves, W.L.A. [Department of Electrical Engineering, Federal University of Campina Grande, Av. Aprigio Veloso, 882 Bodocongo, 58.109-970 Campina Grande, PB (Brazil); Vasconcelos, J.C.A. [Companhia Hidro Eletrica do Sao Francisco, Rua Delmiro Gouveia, 333 Bongi, 50.761-901 Recife, PE (Brazil)

    2007-02-15

    In this work, an accurate coupling capacitor voltage transformer (CCVT) model for electromagnetic transient studies is presented. The model takes into account linear and nonlinear elements. A support routine was developed to compute the linear 230kV CCVT parameters (resistances, inductances and capacitances) from frequency response data. The magnetic core and surge arrester nonlinear characteristics were estimated from laboratory measurements as well. The model is used in connection with the electromagnetic transients program (EMTP) to predict the CCVT performance when it is submitted to transient overvoltages, as are the cases of voltages due to the ferroresonance phenomenon and circuit breaker switching. The difference between simulated and measured results is fairly small. Simulations had shown that transient overvoltages produced inside the CCVT, when a short circuit is cleared at the CCVT secondary side, are effectively damped out by the ferroresonance suppression circuit and the protection circuit. (author)

  15. Digitally Recorded Impulse Voltage Waveform and its Parameters

    Science.gov (United States)

    Sato, Shuji; Ichikawa, Hironori; Saitou, Tatsunori; Harada, Tatsuya; Hanai, Masahiro

    Whereas high resolution digital recorders are used in recording the impulse voltage tests in prominent accreditation laboratories worldwide, a usage of an 8 bit recorder is also allowed by IEC publication. An 8 bit recorder is, due to its nature, known to record a waveform with 0.4% vertical resolution and it has not been appreciated for determining a peak value of lightning impulse in the reference measuring system where the scale factor is often evaluated with 0.1% or less uncertainty. This paper demonstrates simulation in which an 8 bit record with an internal noise is fed into the lightning impulse parameter determination software and the computed parameters were compared with theoretical values. The results show that, if suitable software is used, errors in parameters deduced from an 8 bit record is as small as those derived from a 12 bit record, suggesting an inexpensive 8 bit recorder can replace a 12 bit in impulse voltage measurements.

  16. High Voltage Tests in the LUX-ZEPLIN System Test

    Science.gov (United States)

    Whitis, Thomas; Lux-Zeplin Collaboration

    2016-03-01

    The LUX-ZEPLIN (LZ) project is a dark matter direct detection experiment using liquid xenon. The detector is a time projection chamber (TPC) requiring the establishment of a large electric field inside of the detector in order to drift ionization electrons. Historically, many xenon TPC designs have been unable to reach their design fields due to light production and breakdown. The LZ System Test is scaled so that with a cathode voltage of -50 kV, it will have the fields that will be seen in the LZ detector at -100 kV. It will use a fully instrumented but scaled-down version of the LZ TPC design with a vessel set and gas system designed for quick turnaround, allowing for iterative modifications to the TPC prototype and instrumentation. This talk will present results from the high voltage tests performed during the first runs of the LZ System Test.

  17. Intelligent distributed voltage control system for smart grid application

    Energy Technology Data Exchange (ETDEWEB)

    Sajadi, Amirhossein [Warsaw Univ. of Technology (Poland); Ariatabar, Mitra [RWTH Aachen Univ. (Germany)

    2012-07-01

    Increasing penetration of the renewable energy source (RES) units in distribution networks particularly due to nonlinear and unpredictable nature of renewable units brings up new challenges in different aspects of electricity network, which leads to more complex power systems. Multi-agent system is consisting of agents which are capable to perceive environment that they are located in and to reacts with each other by communication infrastructure in order to achieve overall goals. In this paper an approach to control the voltage based on in the power distribution system is proposed and discussed. Therefore, a multi-agent system has been integrated with artificial intelligence to come up with fuzzy multi-agent based system. The proposed control scheme is deployed to a smart distribution system consisting distribution generation units, modelled in MATLAB/Simulink, to evaluate its effectiveness. The simulation results show how proposed system can regulate voltage in smart distribution feeders. (orig.)

  18. Genetic Algorithm-Based Artificial Neural Network for Voltage Stability Assessment

    OpenAIRE

    Garima Singh; Laxmi Srivastava

    2011-01-01

    With the emerging trend of restructuring in the electric power industry, many transmission lines have been forced to operate at almost their full capacities worldwide. Due to this, more incidents of voltage instability and collapse are being observed throughout the world leading to major system breakdowns. To avoid these undesirable incidents, a fast and accurate estimation of voltage stability margin is required. In this paper, genetic algorithm based back propagation neural network (GABPNN...

  19. Fuel Cell/Electrochemical Cell Voltage Monitor

    Science.gov (United States)

    Vasquez, Arturo

    2012-01-01

    A concept has been developed for a new fuel cell individual-cell-voltage monitor that can be directly connected to a multi-cell fuel cell stack for direct substack power provisioning. It can also provide voltage isolation for applications in high-voltage fuel cell stacks. The technology consists of basic modules, each with an 8- to 16-cell input electrical measurement connection port. For each basic module, a power input connection would be provided for direct connection to a sub-stack of fuel cells in series within the larger stack. This power connection would allow for module power to be available in the range of 9-15 volts DC. The relatively low voltage differences that the module would encounter from the input electrical measurement connection port, coupled with the fact that the module's operating power is supplied by the same substack voltage input (and so will be at similar voltage), provides for elimination of high-commonmode voltage issues within each module. Within each module, there would be options for analog-to-digital conversion and data transfer schemes. Each module would also include a data-output/communication port. Each of these ports would be required to be either non-electrical (e.g., optically isolated) or electrically isolated. This is necessary to account for the fact that the plurality of modules attached to the stack will normally be at a range of voltages approaching the full range of the fuel cell stack operating voltages. A communications/ data bus could interface with the several basic modules. Options have been identified for command inputs from the spacecraft vehicle controller, and for output-status/data feeds to the vehicle.

  20. Quantitative relationship between the maximum streamer length and discharge voltage of a pulsed positive streamer discharge in water

    Science.gov (United States)

    Wen, Xiaoqiong; Li, Qian; Li, Jingsen; Ren, Chunsheng

    2017-08-01

    A linear relationship has been realized between the maximum streamer length and discharge voltage of a pulsed positive streamer discharge by measuring the streamer length in water with conductivity of 100 μS cm-1 using high-speed photography. Based on Ohm’s law, a quantitative equation has been derived for the dependence of the maximum streamer length on the discharge voltage of a pulsed positive streamer discharge in water. According to the equation, our results suggest that the streamers spontaneously stop propagating through water due to the voltage at the streamer head dropping below the ignition voltage of a pulsed positive streamer discharge.

  1. Modeling and Design of DC Boost and AC Side Voltage Controllers in Asymmetrical Γ-Source Inverter

    OpenAIRE

    2014-01-01

    In this paper a control system is proposed to simultaneously control the voltage boost and output voltage of assymetrical Γ-Source Inverters. Dynamic model of the system is used to design the controllers. Voltage boost on assymetrical Γ-Source Inverters is done by voltage control of impedance network capacitor and the regulation of inverter shoot through duty cycle. Since the stability margin of the system is low due to the right half plane zero in its dynamic model, the design of fast contro...

  2. High voltage electricity installations a planning perspective

    CERN Document Server

    Jay, Stephen Andrew

    2006-01-01

    The presence of high voltage power lines has provoked widespread concern for many years. High Voltage Electricity Installations presents an in-depth study of policy surrounding the planning of high voltage installations, discussing the manner in which they are percieved by the public, and the associated environmental issues. An analysis of these concerns, along with the geographical, environmental and political influences that shape their expression, is presented. Investigates local planning policy in an area of the energy sector that is of highly topical environmental and public concern Cover

  3. Piezoelectric Voltage Coupled Reentrant Cavity Resonator

    CERN Document Server

    Carvalho, Natalia C; Floch, Jean-Michel Le; Tobar, Michael Edmund

    2014-01-01

    A piezoelectric voltage coupled microwave reentrant cavity has been developed. The central cavity post is bonded to a piezoelectric actuator allowing the voltage control of small post displacements over a high dynamic range. We show that such a cavity can be implemented as a voltage tunable resonator, a transducer for exciting and measuring mechanical modes of the structure and a transducer for measuring comparative sensitivity of the piezoelectric material. Experiments were conducted at room and cryogenic temperatures with results verified using Finite Element software.

  4. Voltage controlled spintronics device for logic applications.

    Energy Technology Data Exchange (ETDEWEB)

    Bader, S. D.; You, C.-Y.

    1999-09-03

    We consider logic device concepts based on our previously proposed spintronics device element whose magnetization orientation is controlled by application of a bias voltage instead of a magnetic field. The basic building block is the voltage-controlled rotation (VCR) element that consists of a four-layer structure--two ferromagnetic layers separated by both nanometer-thick insulator and metallic spacer layers. The interlayer exchange coupling between the two ferromagnetic layers oscillates as a function of applied voltage. We illustrate transistor-like concepts and re-programmable logic gates based on VCR elements.

  5. The effect of reactive power generation modeling on voltage stability analysis

    Energy Technology Data Exchange (ETDEWEB)

    Tovar, E.; Guizar, J.G.C. [Inst. de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2010-08-13

    One of the most significant concerns for power system planning and operation in many countries involves problems related to voltage instability in electrical power systems. Blackouts have been caused by voltage instability problems throughout the world during the last few decades. Several factors can contribute to long term voltage instability problems, including high active and reactive loading, operation of on load tap changer transformers, inadequate locally available reactive power resources, load characteristics at low voltage magnitudes and operation of relay protection. There is a significant need to evaluate an index which gives the operating point proximity to voltage instability. This paper examined the influence of generator voltage dependent reactive power production on system voltage stability using the minimum singular value from the Jacobian Matrix of the load flow formulation. The synchronous generator model considered voltage reactive power limits due to maximum armature current, maximum and minimum field current as well as under excitation limiters. The generation model used in this paper was included in an ordinary load flow program, and resulted from studies of a representative 62 bus Norwest control area Mexican system, which included 19 generators. Specifically, the paper discussed the generator model with particular reference to the maximum field current limit; armature current limit; minimum field current limit; and underexcitation limit. The singular value decomposition and computational results were also presented. It was concluded that as the loading of the system increases, the reactive power produced by the machines also increases, and that reactive power is delivered when the induced voltage is greater than the terminal voltage. 15 refs., 3 tabs., 2 figs.

  6. Enhancement of Voltage Stability by Optimal Location of Static Var Compensator Using Genetic Algorithm and Particle Swarm Optimization

    Directory of Open Access Journals (Sweden)

    R. Kalaivani

    2012-01-01

    Full Text Available Problem statement: Voltage instability and voltage collapse have been considered as a major threat to present power system networks due to their stressed operation. It is very important to do the power system analysis with respect to voltage stability. Approach: Flexible AC Transmission System (FACTS is an alternating current transmission system incorporating power electronic-based and other static controllers to enhance controllability and increase power transfer capability. A FACTS device in a power system improves the voltage stability, reduces the power loss and also improves the load ability of the system. Results: This study investigates the application of Particle Swarm Optimization (PSO and Genetic Algorithm (GA to find optimal location and rated value of Static Var Compensator (SVC device to minimize the voltage stability index, total power loss, load voltage deviation, cost of generation and cost of FACTS devices to improve voltage stability in the power system. Optimal location and rated value of SVC device have been found in different loading scenario (115%, 125% and 150% of normal loading using PSO and GA. Conclusion/Recommendations: It is observed from the results that the voltage stability margin is improved, the voltage profile of the power system is increased, load voltage deviation is reduced and real power losses also reduced by optimally locating SVC device in the power system. The proposed algorithm is verified with the IEEE 14 bus, IEEE 30 bus and IEEE 57 bus.

  7. Modeling and Design of DC Boost and AC Side Voltage Controllers in Asymmetrical Γ-Source Inverter

    Directory of Open Access Journals (Sweden)

    Seyed Mahyar Mehdizadeh Moghadam

    2014-07-01

    Full Text Available In this paper a control system is proposed to simultaneously control the voltage boost and output voltage of assymetrical Γ-Source Inverters. Dynamic model of the system is used to design the controllers. Voltage boost on assymetrical Γ-Source Inverters is done by voltage control of impedance network capacitor and the regulation of inverter shoot through duty cycle. Since the stability margin of the system is low due to the right half plane zero in its dynamic model, the design of fast control system is impossible therefore a nonlinear feedforward control loop is used to faster the control system performance. Linear control system is used to control the AC-side in synchrony reference frame such that the AC voltage control system regulates the output voltage by means of modulation index regulation. The proposed control system performance is investigated by simulation in MATLAB/Simulink

  8. Programmable high voltage power supply with regulation confined to the high voltage section

    Science.gov (United States)

    Castell, Karen D. (Inventor); Ruitberg, Arthur P. (Inventor)

    1994-01-01

    A high voltage power supply in a dc-dc converter configuration includes a pre-regulator which filters and regulates the dc input and drives an oscillator which applies, in turn, a low voltage ac signal to the low side of a step-up high voltage transformer. The high voltage side of the transformer drives a voltage multiplier which provides a stepped up dc voltage to an output filter. The output voltage is sensed by a feedback network which then controls a regulator. Both the input and output of the regulator are on the high voltage side, avoiding isolation problems. The regulator furnishes a portion of the drive to the voltage multiplier, avoiding having a regulator in series with the load with its attendant, relatively high power losses. This power supply is highly regulated, has low power consumption, a low parts count and may be manufactured at low cost. The power supply has a programmability feature that allows for the selection of a large range of output voltages.

  9. Can undersea voltage measurements detect tsunamis?

    Digital Repository Service at National Institute of Oceanography (India)

    Manoj, C.; Kuvshinov, A.; Neetu, S.; Harinarayana, T.

    The movement of electrically conducting ocean water in the ambient geomagnetic field induces secondary electric and magnetic fields in the oceans. Ocean water transport is now routinely inferred from undersea cable voltage data. We try to answer...

  10. Low voltage arc formation in railguns

    Science.gov (United States)

    Hawke, Ronald S.

    1987-01-01

    A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

  11. Induced voltage in an open wire

    CERN Document Server

    Morawetz, K; Trupp, A

    2015-01-01

    A puzzle arising from Faraday's law is considered and solved concerning the question which voltage is induced in an open wire feeling a time-varying homogeneous magnetic field. The longitudinal electric field contributes 1/3 and the transverse field 2/3 to the induced voltage. The representation of a homogeneous and time-varying magnetic field implies unavoidably a certain symmetry point or line dependent on the geometry of the source. As a consequence the induced voltage of an open wire is found to be the area covered with respect to the symmetry line or point perpendicular to the magnetic field. This in turn allows to find the symmetry points of a magnetic field source by measuring the voltage of an open wire. We present two exactly solvable models for a symmetry point and for a symmetry line. The results are applicable to open circuit problems and for astrophysical applications.

  12. High voltage and electrical insulation engineering

    CERN Document Server

    Arora, Ravindra

    2011-01-01

    "The book is written for students as well as for teachers and researchers in the field of High Voltage and Insulation Engineering. It is based on the advance level courses conducted at TU Dresden, Germany and Indian Institute of Technology Kanpur, India. The book has a novel approach describing the fundamental concept of field dependent behavior of dielectrics subjected to high voltage. There is no other book in the field of high voltage engineering following this new approach in describing the behavior of dielectrics. The contents begin with the description of fundamental terminology in the subject of high voltage engineering. It is followed by the classification of electric fields and the techniques of field estimation. Performance of gaseous, liquid and solid dielectrics under different field conditions is described in the subsequent chapters. Separate chapters on vacuum as insulation and the lightning phenomenon are included"--

  13. Combined Digital Electronic Current and Voltage Transducer

    Institute of Scientific and Technical Information of China (English)

    段雄英; 邹积岩; 等

    2002-01-01

    A high-performance current and voltage measurement system has been developed in power system.The system is composed of two parts:one current measurement element and one voltage measurement element.A Rogowski coil and a capacitive voltage divider are used respectively for the line current and voltage measurements.Active electronic components are used to modulate signal,and power supply for these components is drawn from power line via an auxiliary current transformer,Measurement signal is transmitted y optical fibers,which is resistant to electromagnetic induction and noise,With careful design and the use of digital signal processing technology,the whole system can meet 0.5% accuracy for metering and provides large dynamic range coupled with good accuracy for protective relaying use.

  14. Compact, Lightweight, High Voltage Propellant Isolators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  15. Compact, Lightweight, High Voltage Propellant Isolators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  16. Voltage, Temperature, Frequency Margin Test Report

    DEFF Research Database (Denmark)

    Denver, Troelz

    1999-01-01

    The purpose of the tests is to establish the camera functionality when it is exposed to an extreme environment for prolonged periods, thus simulating the end of life performance. This environment covers temperature, input clock frequency and supply voltage variation......The purpose of the tests is to establish the camera functionality when it is exposed to an extreme environment for prolonged periods, thus simulating the end of life performance. This environment covers temperature, input clock frequency and supply voltage variation...

  17. Joint voltages resulting from lightning currents.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, William Arthur; Warne, Larry Kevin; Merewether, Kimball O.; Chen, Kenneth C.

    2007-03-01

    Simple formulas are given for the interior voltages appearing across bolted joints from exterior lightning currents. External slot and bolt inductances as well as internal slot and bolt diffusion effects are included. Both linear and ferromagnetic wall materials are considered. A useful simplification of the slot current distribution into linear stripline and cylindrical parts (near the bolts) allows the nonlinear voltages to be estimated in closed form.

  18. Voltage Mode-to-Current Mode Transformation

    Directory of Open Access Journals (Sweden)

    Tejmal S. Rathore

    2012-10-01

    Full Text Available This paper proposes a procedure for converting a class of Op Amp-, FTFN-, CC- and CFAbased voltage mode circuits to corresponding current mode circuits without requiring any additional circuit elements and finally from Op Amp-based voltage mode circuits to any of the FTFN, CC and CFA current mode circuits. The latter circuits perform better at high frequency than the former ones. The validity of the transformation has been checked on simulated circuits with PSPICE.

  19. Low-Voltage Hall Thruster Mode Transitions

    Science.gov (United States)

    2014-06-01

    Technical Paper 3. DATES COVERED (From - To) June 2014- July 2014 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER In-House Low-Voltage Hall Thruster Mode...ABSTRACT Past investigations of the 6kW-class H6 Hall thruster during low-voltage operation revealed two operating modes, corresponding to the...topologies were characterized for the H6 Hall thruster from 100V to 200V discharge, with variation in cathode flow fraction, cathode position inside and

  20. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F.; Yee, Daniel D.

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  1. Wind Power Plant Voltage Stability Evaluation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Zhang, Y. C.

    2014-09-01

    Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

  2. VKCDB: Voltage-gated potassium channel database

    Directory of Open Access Journals (Sweden)

    Gallin Warren J

    2004-01-01

    Full Text Available Abstract Background The family of voltage-gated potassium channels comprises a functionally diverse group of membrane proteins. They help maintain and regulate the potassium ion-based component of the membrane potential and are thus central to many critical physiological processes. VKCDB (Voltage-gated potassium [K] Channel DataBase is a database of structural and functional data on these channels. It is designed as a resource for research on the molecular basis of voltage-gated potassium channel function. Description Voltage-gated potassium channel sequences were identified by using BLASTP to search GENBANK and SWISSPROT. Annotations for all voltage-gated potassium channels were selectively parsed and integrated into VKCDB. Electrophysiological and pharmacological data for the channels were collected from published journal articles. Transmembrane domain predictions by TMHMM and PHD are included for each VKCDB entry. Multiple sequence alignments of conserved domains of channels of the four Kv families and the KCNQ family are also included. Currently VKCDB contains 346 channel entries. It can be browsed and searched using a set of functionally relevant categories. Protein sequences can also be searched using a local BLAST engine. Conclusions VKCDB is a resource for comparative studies of voltage-gated potassium channels. The methods used to construct VKCDB are general; they can be used to create specialized databases for other protein families. VKCDB is accessible at http://vkcdb.biology.ualberta.ca.

  3. SIMULATION OF INTERLINE DYNAMIC VOLTAGE RESTORER

    Directory of Open Access Journals (Sweden)

    J.Singaravelan

    2011-08-01

    Full Text Available This paper presents a new approach for the dynamic control of a current source inverter (CSI using Super Conductive Magnetic energy storage (SMES based Interline DVR. The dynamic voltage restorer (DVR provides a technically advanced and economical solution to voltage-sag problem. As the voltage-restoration process involves the real-power injection into the distribution system, the capability ofa DVR, especially for compensating long-duration voltage sags, it depends on the energy storage capacity of the DVR. The interline DVR proposed in this paper provides a way to replenish Dc-link energy storage dynamically. The IDVR consists of several DVRs connected to different distribution feeders in the power system. The DVRs in the IDVR system shares the common energy storage. When one of the DVRcompensates for voltage sag appearing in that feeder, the other DVRs replenish the energy in the common dc-link dynamically. Thus, one DVR in the IDVR system works in voltage-sag compensation mode whilethe other DVRs in the IDVR system operate in power-flow control mode. The proposed topology is simulated using Matlab/Simulink and total IDVR system is simulated using Matlab/Simulink.

  4. Improving transition voltage spectroscopy of molecular junctions

    Science.gov (United States)

    Markussen, Troels; Chen, Jingzhe; Thygesen, Kristian S.

    2011-04-01

    Transition voltage spectroscopy (TVS) is a promising spectroscopic tool for molecular junctions. The principles in TVS is to find the minimum on a Fowler-Nordheim plot where ln(I/V2) is plotted against 1/V and relate the voltage at the minimum Vmin to the closest molecular level. Importantly, Vmin is approximately half the voltage required to see a peak in the dI/dV curve. Information about the molecular level position can thus be obtained at relatively low voltages. In this work we show that the molecular level position can be determined at even lower voltages, Vmin(α), by finding the minimum of ln(I/Vα) with α<2. On the basis of a simple Lorentzian transmission model we analyze theoretical ab initio as well as experimental I-V curves and show that the voltage required to determine the molecular levels can be reduced by ~30% as compared to conventional TVS. As for conventional TVS, the symmetry/asymmetry of the molecular junction needs to be taken into account in order to gain quantitative information. We show that the degree of asymmetry may be estimated from a plot of Vmin(α) vs α.

  5. Experimental validation of prototype high voltage bushing

    Science.gov (United States)

    Shah, Sejal; Tyagi, H.; Sharma, D.; Parmar, D.; M. N., Vishnudev; Joshi, K.; Patel, K.; Yadav, A.; Patel, R.; Bandyopadhyay, M.; Rotti, C.; Chakraborty, A.

    2017-08-01

    Prototype High voltage bushing (PHVB) is a scaled down configuration of DNB High Voltage Bushing (HVB) of ITER. It is designed for operation at 50 kV DC to ensure operational performance and thereby confirming the design configuration of DNB HVB. Two concentric insulators viz. Ceramic and Fiber reinforced polymer (FRP) rings are used as double layered vacuum boundary for 50 kV isolation between grounded and high voltage flanges. Stress shields are designed for smooth electric field distribution. During ceramic to Kovar brazing, spilling cannot be controlled which may lead to high localized electrostatic stress. To understand spilling phenomenon and precise stress calculation, quantitative analysis was performed using Scanning Electron Microscopy (SEM) of brazed sample and similar configuration modeled while performing the Finite Element (FE) analysis. FE analysis of PHVB is performed to find out electrical stresses on different areas of PHVB and are maintained similar to DNB HV Bushing. With this configuration, the experiment is performed considering ITER like vacuum and electrical parameters. Initial HV test is performed by temporary vacuum sealing arrangements using gaskets/O-rings at both ends in order to achieve desired vacuum and keep the system maintainable. During validation test, 50 kV voltage withstand is performed for one hour. Voltage withstand test for 60 kV DC (20% higher rated voltage) have also been performed without any breakdown. Successful operation of PHVB confirms the design of DNB HV Bushing. In this paper, configuration of PHVB with experimental validation data is presented.

  6. Effects on lifetime of low voltage conductors due to stationary power quality disturbances

    Directory of Open Access Journals (Sweden)

    Ivan Camilo Duran-Tovar

    2015-01-01

    Full Text Available Este artículo present a una metodología para la estimación de lo s efectos en el calentamiento y la esperanza de vida en conduct ores de baja tensión (BT debido a la presenc ia de perturbaciones estacionar ias de calidad de potencia. El sobrecalentamiento del conductor y el prematuro envejecimiento en el ais lamiento del cable puede ser causado por los incrementos temporales en los valores RMS de la s tensiones y las corrientes ocasionados por perturbaciones estacionarias. Entre las perturbaciones están las distorsiones de forma de ond a, desbalances y los desplazamientos de fase. Pa ra incrementos de corta duraci ón, no se ven reducciones significativas en el tiempo de vida d el aislamiento, pero para largos periodos de tiem po se puede producir efectos a cumulativos y degenerativos. Se emplean modelos válidos actualm ente para envejecimiento del aislamien to; los niveles esperados de l as perturbaciones de calidad de potencia son extraídos de bases de datos de calidad de potencia. U na discusión sobre los efectos en el tiem po de vida del aislamiento es presentada.

  7. Multifunction Voltage-Mode Filter Using Single Voltage Differencing Differential Difference Amplifier

    Directory of Open Access Journals (Sweden)

    Chaichana Amornchai

    2017-01-01

    Full Text Available In this paper, a voltage mode multifunction filter based on single voltage differencing differential difference amplifier (VDDDA is presented. The proposed filter with three input voltages and single output voltage is constructed with single VDDDA, two capacitors and two resistors. Its quality factor can be adjusted without affecting natural frequency. Also, the natural frequency can be electronically tuned via adjusting of bias current. The filter can offer five output responses, high-pas (HP, band-pass (BP, band-reject (BR, low-pass (LP and all-ass (AP functions in the same circuit topology. The output response can be selected by choosing the suitable input voltage without the component matching condition and the requirement of additional double gain voltage amplifier. PSpice simulation results to confirm an operation of the proposed filter correspond to the theory.

  8. Reversible voltage dependent transition of abnormal and normal bipolar resistive switching

    Science.gov (United States)

    Wang, Guangyu; Li, Chen; Chen, Yan; Xia, Yidong; Wu, Di; Xu, Qingyu

    2016-11-01

    Clear understanding the mechanism of resistive switching is the important prerequisite for the realization of high performance nonvolatile resistive random access memory. In this paper, binary metal oxide MoOx layer sandwiched by ITO and Pt electrodes was taken as a model system, reversible transition of abnormal and normal bipolar resistive switching (BRS) in dependence on the maximum voltage was observed. At room temperature, below a critical maximum voltage of 2.6 V, butterfly shaped I-V curves of abnormal BRS has been observed with low resistance state (LRS) to high resistance state (HRS) transition in both polarities and always LRS at zero field. Above 2.6 V, normal BRS was observed, and HRS to LRS transition happened with increasing negative voltage applied. Temperature dependent I-V measurements showed that the critical maximum voltage increased with decreasing temperature, suggesting the thermal activated motion of oxygen vacancies. Abnormal BRS has been explained by the partial compensation of electric field from the induced dipoles opposite to the applied voltage, which has been demonstrated by the clear amplitude-voltage and phase-voltage hysteresis loops observed by piezoelectric force microscopy. The normal BRS was due to the barrier modification at Pt/MoOx interface by the accumulation and depletion of oxygen vacancies.

  9. Variable speed wind turbine generator system with current controlled voltage source inverter

    Energy Technology Data Exchange (ETDEWEB)

    Muyeen, S.M., E-mail: muyeen0809@yahoo.co [Dept. of Electrical Engineering, Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Al-Durra, Ahmed [Dept. of Electrical Engineering, The Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Tamura, J. [Dept. of EEE, Kitami Institute of Technology, 165 Koen-cho, Kitami 090-8507 (Japan)

    2011-07-15

    highlights: {yields} Current controlled voltage source inverter scheme for wind power application. {yields} Low voltage ride through of wind farm. {yields} Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  10. Current-voltage characteristic of a resonant tunneling diode under electromagnetic radiation

    Directory of Open Access Journals (Sweden)

    N Hatefi Kargan

    2013-09-01

    Full Text Available  In this paper, current-voltage characteristic of a resonant tunneling diode under electromagnetic radiation has been calculated and compared with the results when there is no electromagnetic radiation. For calculating current -voltage characteristic, it is required to calculate the transmission coefficient of electrons from the well and barrier structures of this device. For calculating the transmission coefficient of electrons at the presence of electromagnetic radiation, Finite Difference Time Domain (FDTD method has been used and when there is no electromagnetic radiation Transfer Matrix Method (TMM and finite diffirence time domain method have been used. The results show that the presence of electromagnetic radiation causes resonant states other than principal resonant state (without presence of electromagnetic radiation to appear on the transmition coefficient curve where they are in distances from the principal peak and from each other. Also, the presence of electromagnetic radiation causes peaks other than principal peak to appear on the current-voltage characteristics of the device. Under electromagnetic radiation, the number of peaks on the current-voltage curve is smaller than the number of peaks on the current-voltage transmission coefficient. This is due to the fact that current-voltage curve is the result of integration on the energy of electrons, Thus, the sharper and low height peaks on the transmission coefficient do not appear on the current-voltage characteristic curve.

  11. Selection of the Optimum Electrospray Voltage for Gradient Elution LC-MS Measurements

    Science.gov (United States)

    Marginean, Ioan; Kelly, Ryan T.; Moore, Ronald J.; Prior, David C.; LaMarche, Brian L.; Tang, Keqi; Smith, Richard D.

    2009-01-01

    Changes in liquid composition during gradient elution liquid chromatography (LC) coupled to mass spectrometry (MS) analyses affect the electrospray operation. To establish methodologies for judicious selection of the electrospray voltage, we monitored in real-time the effect of the LC gradient on the spray current. The optimum range of the electrospray voltage decreased as the concentration of organic solvent in the eluent increased during reversed-phase LC analyses. These results provided the means to rationally select the voltage so as to ensure effective electrospray operation throughout gradient-elution LC separations. For analyses in which the electrospray was operated at constant voltage, a small run-to-run variation in the spray current was observed, indicating a changing electric field due to fouling or degradation of the emitter. Algorithms using feedback from spray current measurements to maintain the electrospray voltage within the optimum operating range throughout gradient elution LC-MS were evaluated. The electrospray operation with voltage regulation and at a constant, judiciously selected voltage during gradient elution LC-MS measurements produced data with similar reproducibility. SYNOPSIS Electrospray current measurements during gradient elution liquid chromatography analyses provide reliable feedback for monitoring, understanding, and improving performance. PMID:19196520

  12. Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid

    Science.gov (United States)

    Armstrong, Michael J.; Blackwelder, Mark; Bollman, Andrew; Ross, Christine; Campbell, Angela; Jones, Catherine; Norman, Patrick

    2015-01-01

    The development of a wholly superconducting turboelectric distributed propulsion system presents unique opportunities for the aerospace industry. However, this transition from normally conducting systems to superconducting systems significantly increases the equipment complexity necessary to manage the electrical power systems. Due to the low technology readiness level (TRL) nature of all components and systems, current Turboelectric Distributed Propulsion (TeDP) technology developments are driven by an ambiguous set of system-level electrical integration standards for an airborne microgrid system (Figure 1). While multiple decades' worth of advancements are still required for concept realization, current system-level studies are necessary to focus the technology development, target specific technological shortcomings, and enable accurate prediction of concept feasibility and viability. An understanding of the performance sensitivity to operating voltages and an early definition of advantageous voltage regulation standards for unconventional airborne microgrids will allow for more accurate targeting of technology development. Propulsive power-rated microgrid systems necessitate the introduction of new aircraft distribution system voltage standards. All protection, distribution, control, power conversion, generation, and cryocooling equipment are affected by voltage regulation standards. Information on the desired operating voltage and voltage regulation is required to determine nominal and maximum currents for sizing distribution and fault isolation equipment, developing machine topologies and machine controls, and the physical attributes of all component shielding and insulation. Voltage impacts many components and system performance.

  13. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    Directory of Open Access Journals (Sweden)

    C. Yong-Nong

    2013-03-01

    Full Text Available In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The powersupply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to theindispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer needconsidering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, butalso parasitic capacitance resulted from the insulation wrappings on the high-voltage side. This research exhibits asimple approach to measuring equivalent circuit parameters of the high-frequency, high-voltage transformer with straycapacitance being introduced into the conventional modeling. The proposed modeling scheme provides not only aprecise measurement procedure but also effective design information for series-load resonant converter. The plasmadischarging plate is designed as part of the electric circuit in the series load-resonant converter and the circuit modelof the plasma discharging plate is also conducted as well. Thus, the overall model of the high-voltage plasmagenerator is built and the designing procedures for appropriate selections of the corresponding resonant-circuitparameters can be established. Finally, a high-voltage plasma generator with 220V, 60Hz, and 1kW input, along witha 22 kHz and over 8kV output, is realized and implemented.

  14. Bottlenecks reduction using superconductors in high voltage transmission lines

    Directory of Open Access Journals (Sweden)

    Daloub Labib

    2016-01-01

    Full Text Available Energy flow bottlenecks in high voltage transmission lines known as congestions are one of the challenges facing power utilities in fast developing countries. Bottlenecks occur in selected power lines when transmission systems are operated at or beyond their transfer limits. In these cases, congestions result in preventing new power supply contracts, infeasibility in existing contracts, price spike and market power abuse. The “Superconductor Technology” in electric power transmission cables has been used as a solution to solve the problem of bottlenecks in energy transmission at high voltage underground cables and overhead lines. The increase in demand on power generation and transmission happening due to fast development and linked to the intensive usage of transmission network in certain points, which in turn, lead to often frequent congestion in getting the required power across to where it is needed. In this paper, a bottleneck in high voltage double overhead transmission line with Aluminum Conductor Steel Reinforced was modeled using conductor parameters and replaced by Gap-Type Superconductor to assess the benefit of upgrading to higher temperature superconductor and obtain higher current carrying capacity. This proved to reduce the high loading of traditional aluminum conductors and allow more power transfer over the line using superconductor within the same existing right-of-way, steel towers, insulators and fittings, thus reducing the upgrade cost of building new lines.

  15. Thermally-induced voltage alteration for integrated circuit analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Jr., Edward I. (Albuquerque, NM)

    2000-01-01

    A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.

  16. Thermally-induced voltage alteration for integrated circuit analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cole, E.I. Jr.

    2000-06-20

    A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.

  17. Program-Controlled High Voltage Module in Active Voltage Dividers(AVD) for MPGD

    CERN Document Server

    Ginting, Muhammad Fadhil

    2016-01-01

    Micro Pattern Gas Detectors (MPGD) applications are rapidly developing and became an important part of upgrades for the LHC detectors. RD51/CERN have worked on Active Voltage Divider (AVD) technology for multistage MPGDs, One of the next developments for the AVD is to design and integrate high voltage module in a single box. The Program-Controlled High Voltage Module, part of one AIDA2020 project, has been successfully designed and developed, and can be integrated in AVD design.

  18. Mitigation of Voltage Dip and Voltage Flickering by Multilevel D-STATCOM

    Directory of Open Access Journals (Sweden)

    M. S. Ballal

    2012-01-01

    Full Text Available The basic power quality problems in the distribution network are voltage sag (dip, voltage flickering, and the service interruptions. STATCOM is a Flexible AC Transmission Systems (FACTS technology device which can independently control the flow of reactive power. This paper presents the simulation and analysis of a STATCOM for voltage dip and voltage flickering mitigation. Simulations are carried out in MATLAB/Simulink to validate the performance of the STATCOM. A comparison between the six-pulse inverter and the five-level diode-clamped inverter is carried out for the performance of 66/11 KV distribution system.

  19. Engineering of a Genetically Encodable Fluorescent Voltage Sensor Exploiting Fast Ci-VSP Voltage-Sensing Movements

    OpenAIRE

    Alicia Lundby; Hiroki Mutoh; Dimitar Dimitrov; Walther Akemann; Thomas Knöpfel

    2008-01-01

    Ci-VSP contains a voltage-sensing domain (VSD) homologous to that of voltage-gated potassium channels. Using charge displacement ('gating' current) measurements we show that voltage-sensing movements of this VSD can occur within 1 ms in mammalian membranes. Our analysis lead to development of a genetically encodable fluorescent protein voltage sensor (VSFP) in which the fast, voltage-dependent conformational changes of the Ci-VSP voltage sensor are transduced to similarly fast fluorescence re...

  20. Voltage scheduling for low power/energy

    Science.gov (United States)

    Manzak, Ali

    2001-07-01

    Power considerations have become an increasingly dominant factor in the design of both portable and desk-top systems. An effective way to reduce power consumption is to lower the supply voltage since voltage is quadratically related to power. This dissertation considers the problem of lowering the supply voltage at (i) the system level and at (ii) the behavioral level. At the system level, the voltage of the variable voltage processor is dynamically changed with the work load. Processors with limited sized buffers as well as those with very large buffers are considered. Given the task arrival times, deadline times, execution times, periods and switching activities, task scheduling algorithms that minimize energy or peak power are developed for the processors equipped with very large buffers. A relation between the operating voltages of the tasks for minimum energy/power is determined using the Lagrange multiplier method, and an iterative algorithm that utilizes this relation is developed. Experimental results show that the voltage assignment obtained by the proposed algorithm is very close (0.1% error) to that of the optimal energy assignment and the optimal peak power (1% error) assignment. Next, on-line and off-fine minimum energy task scheduling algorithms are developed for processors with limited sized buffers. These algorithms have polynomial time complexity and present optimal (off-line) and close-to-optimal (on-line) solutions. A procedure to calculate the minimum buffer size given information about the size of the task (maximum, minimum), execution time (best case, worst case) and deadlines is also presented. At the behavioral level, resources operating at multiple voltages are used to minimize power while maintaining the throughput. Such a scheme has the advantage of allowing modules on the critical paths to be assigned to the highest voltage levels (thus meeting the required timing constraints) while allowing modules on non-critical paths to be assigned

  1. Extra-High-Voltage DC-DC Boost Converters Topology with Simple Control Strategy

    Directory of Open Access Journals (Sweden)

    K. Rajambal

    2009-01-01

    Full Text Available This paper presents the topology of operating DC-DC buck converter in boost mode for extra-high-voltage applications. Traditional DC-DC boost converters are used in high-voltage applications, but they are not economical due to the limited output voltage, efficiency and they require two sensors with complex control algorithm. Moreover, due to the effect of parasitic elements the output voltage and power transfer efficiency of DC-DC converters are limited. These limitations are overcome by using the voltage lift technique, opens a good way to improve the performance characteristics of DC-DC converter. The technique is applied to DC-DC converter and a simplified control algorithm in this paper. The performance of the controller is studied for both line and load disturbances. These converters perform positive DC-DC voltage increasing conversion with high power density, high efficiency, low cost in simple structure, small ripples, and wide range of control. Simulation results along theoretical analysis are provided to verify its performance.

  2. Lateral current effects on the voltage distribution in the emitter of solar cells under concentrated sunlight

    Energy Technology Data Exchange (ETDEWEB)

    Morales-Acevedo, Arturo [CINVESTAV-IPN, Electrical Engineering Department, Avenida IPN No. 2508, 07360 Mexico, DF (Mexico)

    2009-04-15

    The design of the grid contact in silicon solar cells is one of the most important steps for the optimization and fabrication of these energy conversion devices. The voltage drop due to the lateral flow of current towards the grid fingers can be a limiting factor causing the reduction of conversion efficiency. For low current levels this voltage drop can be made small, for typical values of sheet resistance in the emitter, but for solar cells made to operate at high sun concentrations this efficiency loss can be important, unless there is a clear vision of the current and voltage distribution so that the emitter and grid design can be improved. Hence, it is important to establish and solve the current and voltage distribution equations for solar cells with a grid contact. In this work, first these equations are established and then they are solved in order to show the effects that the lateral current flow in the emitter cause on the voltage distribution, particularly at high illumination levels. In addition, it will be shown that the open circuit voltage is significantly reduced due to the lateral current flow as compared to the value predicted from a simple equivalent circuit with a lumped resistance model. (author)

  3. Pollution Maintenance Techniques in Coastal High Voltage Installations

    Directory of Open Access Journals (Sweden)

    E. Pyrgioti

    2011-02-01

    Full Text Available Pollution of outdoor high voltage insulators is a common problem for utilities, with a considerable impact to power system reliability. In an effort to prevent possible flashovers due to pollution, many methods have been applied, aiming to improve the insulation performance, either by suppressing the formation of surface conductivity or by increasing the possible insulation level. In the case of substations, the selection of the appropriate technique is complex due to certain issues correlated to the nature of the installation. In this paper, several techniques usually implemented by utilities, are investigated based on the experienced gained in the case of Crete, a Greek island in southern Europe, where due to the coastal development of the power system, the majority of high voltage installations are exposed to intense marine pollution. The technique of coating insulators with Room Temperature Vulcanized Silicone Rubber (RTV SIR has proved rather efficient and therefore is presented extendedly. Correlation of the material behaviour with environmental conditions is discussed and results from long term monitoring, including environmental parameters and leakage current measurements, in a 150 kV Substation are presented. It is shown that RTV SIR coatings have remarkably suppressed surface activity and that porcelain insulators exhibit different activity period when coated.

  4. Voltage generation of piezoelectric cantilevers by laser heating.

    Science.gov (United States)

    Hsieh, Chun-Yi; Liu, Wei-Hung; Chen, Yang-Fang; Shih, Wan Y; Gao, Xiaotong; Shih, Wei-Heng

    2012-11-15

    Converting ambient thermal energy into electricity is of great interest in harvesting energy from the environment. Piezoelectric cantilevers have previously been shown to be an effective biosensor and a tool for elasticity mapping. Here we show that a single piezoelectric (lead-zirconate titanate (PZT)) layer cantilever can be used to convert heat to electricity through pyroelectric effect. Furthermore, piezoelectric-metal (PZT-Ti) bi-layer cantilever showed an enhanced induced voltage over the single PZT layer alone due to the additional piezoelectric effect. This type of device can be a way for converting heat energy into electricity.

  5. Diplopia due to Dacryops

    OpenAIRE

    Rahmi Duman; Reşat Duman; Mehmet Balcı

    2013-01-01

    Dacryops is a lacrimal ductal cyst. It is known that it can cause globe displacement, motility restriction, and proptosis because of the mass effect. Diplopia due to dacryops has not been reported previously. Here, we present a 57-year-old man with binocular horizontal diplopia that occurred during left direction gaze due to dacryops.

  6. Diplopia due to Dacryops

    Directory of Open Access Journals (Sweden)

    Rahmi Duman

    2013-01-01

    Full Text Available Dacryops is a lacrimal ductal cyst. It is known that it can cause globe displacement, motility restriction, and proptosis because of the mass effect. Diplopia due to dacryops has not been reported previously. Here, we present a 57-year-old man with binocular horizontal diplopia that occurred during left direction gaze due to dacryops.

  7. The Coefficient of the Voltage Induced Frequency Shift Measurement on a Quartz Tuning Fork

    Directory of Open Access Journals (Sweden)

    Yubin Hou

    2014-11-01

    Full Text Available We have measured the coefficient of the voltage induced frequency shift (VIFS of a 32.768 KHz quartz tuning fork. Three vibration modes were studied: one prong oscillating, two prongs oscillating in the same direction, and two prongs oscillating in opposite directions. They all showed a parabolic dependence of the eigen-frequency shift on the bias voltage applied across the fork, due to the voltage-induced internal stress, which varies as the fork oscillates. The average coefficient of the VIFS effect is as low as several hundred nano-Hz per millivolt, implying that fast-response voltage-controlled oscillators and phase-locked loops with nano-Hz resolution can be built.

  8. A Uniform Voltage Gain Control for Alignment Robustness in Wireless EV Charging

    Directory of Open Access Journals (Sweden)

    Yabiao Gao

    2015-08-01

    Full Text Available The efficiency of wireless power transfer is sensitive to the horizontal and vertical distances between the transmitter and receiver coils due to the magnetic coupling change. To address the output voltage variation and efficiency drop caused by misalignment, a uniform voltage gain frequency control is implemented to improve the power delivery and efficiency of wireless power transfer under misalignment. The frequency is tuned according to the amplitude and phase-frequency characteristics of coupling variations in order to maintain a uniform output voltage in the receiver coil. Experimental comparison of three control methods, including fixed frequency control, resonant frequency control, and the proposed uniform gain control was conducted and demonstrated that the uniform voltage gain control is the most robust method for managing misalignment in wireless charging applications.

  9. Voltage-Driven Magnetization Switching and Spin Pumping in Weyl Semimetals

    Science.gov (United States)

    Kurebayashi, Daichi; Nomura, Kentaro

    2016-10-01

    We demonstrate electrical magnetization switching and spin pumping in magnetically doped Weyl semimetals. The Weyl semimetal is a three-dimensional gapless topological material, known to have nontrivial coupling between the charge and the magnetization due to the chiral anomaly. By solving the Landau-Lifshitz-Gilbert equation for a multilayer structure of a Weyl semimetal, an insulator and a metal while taking the charge-magnetization coupling into account, magnetization dynamics is analyzed. It is shown that the magnetization dynamics can be driven by the electric voltage. Consequently, switching of the magnetization with a pulsed electric voltage can be achieved, as well as precession motion with an applied oscillating electric voltage. The effect requires only a short voltage pulse and may therefore be energetically favorable for us in spintronics devices compared to conventional spin-transfer torque switching.

  10. Tuning the hysteresis voltage in 2D multilayer MoS2 FETs

    Science.gov (United States)

    Jiang, Jie; Zheng, Zhouming; Guo, Junjie

    2016-10-01

    The hysteresis tuning is of great significance before the two-dimensional (2D) molybdenum disulfide (MoS2) field-effect transistors (FETs) can be practically used in the next-generation nanoelectronic devices. In this paper, a simple and effective annealing method was developed to tune the hysteresis voltage in 2D MoS2 transistors. It was found that high temperature (175 °C) annealing in air could increase the hysteresis voltage from 8.0 V (original device) to 28.4 V, while a next vacuum annealing would reduce the hysteresis voltage to be only 2.0 V. An energyband diagram model based on electron trapping/detrapping due to oxygen adsorption is proposed to understand the hysteresis mechanism in multilayer MoS2 FET. This simple method for tuning the hysteresis voltage of MoS2 FET can make a significant step toward 2D nanoelectronic device applications.

  11. Pinch-off voltage modeling for CMOS image pixels with a pinned photodiode structure

    Science.gov (United States)

    Chen, Cao; Bing, Zhang; Longsheng, Wu; Xin, Li; Junfeng, Wang

    2014-07-01

    A novel analytical model of pinch-off voltage for CMOS image pixels with a pinned photodiode structure is proposed. The derived model takes account of the gradient doping distributions in the N buried layer due to the impurity compensation formed by manufacturing processes; the impurity distribution characteristics of two boundary PN junctions located in the region for particular spectrum response of a pinned photodiode are quantitative analyzed. By solving Poisson's equation in vertical barrier regions, the relationships between the pinch-off voltage and the corresponding process parameters such as peak doping concentration, N type width and doping concentration gradient of the N buried layer are established. Test results have shown that the derived model features the variations of the pinch-off voltage versus the process implant conditions more accurately than the traditional model. The research conclusions in this paper provide theoretical evidence for evaluating the pinch-off voltage design.

  12. Role of thermal heating on the voltage induced insulator-metal transition in VO2.

    Science.gov (United States)

    Zimmers, A; Aigouy, L; Mortier, M; Sharoni, A; Wang, Siming; West, K G; Ramirez, J G; Schuller, Ivan K

    2013-02-01

    We show that the main mechanism for the dc voltage or dc current induced insulator-metal transition in vanadium dioxide VO(2) is due to local Joule heating and not a purely electronic effect. This "tour de force" experiment was accomplished by using the fluorescence spectra of rare-earth doped micron sized particles as local temperature sensors. As the insulator-metal transition is induced by a dc voltage or dc current, the local temperature reaches the transition temperature indicating that Joule heating plays a predominant role. This has critical implications for the understanding of the dc voltage or dc current induced insulator-metal transition and has a direct impact on applications which use dc voltage or dc current to externally drive the transition.

  13. High-voltage integrated transmitting circuit with differential driving for CMUTs

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Larsen, Dennis Øland; Færch, Kjartan Ullitz

    2016-01-01

    In this paper, a high-voltage integrated differential transmitting circuit for capacitive micromachined ultrasonic transducers (CMUTs) used in portable ultrasound scanners is presented. Due to its application, area and power consumption are critical and need to be minimized. The circuitry...... is designed and implemented in AMS 0.35 μ m high-voltage process. Measurements are performed on the fabricated integrated circuit in order to assess its performance. The transmitting circuit consists of a low-voltage control logic, pulse-triggered level shifters and a differential output stage that generates...... pulses at differential voltage levels of 60, 80 and 100 V, a frequency up to 5 MHz and a measured driving strength of 2.03 V/ns with the CMUT electrical model connected. The total on-chip area occupied by the transmitting circuit is 0.18 mm2 and the power consumption at the ultrasound scanner operation...

  14. Characterization of high voltage components using partial discharges; Caracterisation de composants haute tension par decharges partielles

    Energy Technology Data Exchange (ETDEWEB)

    Boucheteau, R.; Biero, H.; Prisset, C. [CEA Le Ripault, 37 - Tours (France)

    1996-12-31

    Because of the increasing size reduction of high voltage components, the classical dielectric control means do not allow to predict neither the in-service breakdown probability, nor the service life of the components even when submitted to a voltage greater to the nominal value of use. Therefore a new approach is developed which is based on the measurement of partial discharges (PD) occurring with respect to the voltage applied. PDs are due to impurities inside the materials. Pertinent parameters, such as the PDs occurrence voltage, the mean discharge current and the maximum charge of PDs are defined in order to determine a correlation between the PDs measurement and the state of the insulating material. The influence of aging is not well known. Thus the materials are submitted to more or less severe environments in order to determine the significant evolutions of PDs. (J.S.) 2 refs.

  15. Detecting Power Voltage Dips using Tracking Filters - A Comparison against Kalman

    Directory of Open Access Journals (Sweden)

    STANCIU, I.-R.

    2012-11-01

    Full Text Available Due of its significant economical impact, Power-Quality (PQ analysis is an important domain today. Severe voltage distortions affect the consumers and disturb their activity. They may be caused by short circuits (in this case the voltage drops significantly or by varying loads (with a smaller drop. These two types are the PQ currently issues. Monitoring these phenomena (called dips or sags require powerful techniques. Digital Signal Processing (DSP algorithms are currently employed to fulfill this task. Discrete Wavelet Transforms, (and variants, Kalman filters, and S-Transform are currently proposed by researchers to detect voltage dips. This paper introduces and examines a new tool to detect voltage dips: the so-called tracking filters. Discovered and tested during the cold war, they can estimate a parameter of interest one-step-ahead based on the previously observed values. Two filters are implemented. Their performance is assessed by comparison against the Kalman filter?s results.

  16. Optimized Control Strategy for a Medium-Voltage DVR-Theoretical Investigations and Experimental Results

    DEFF Research Database (Denmark)

    Meyer, Christoph; De Doncker, Rik W.; Li, Yun Wei;

    2008-01-01

    a small fraction of the energy stored in the DC-link capacitor is used, which makes it impractical for DVRs to compensate relatively long voltage sags. Present control strategies are only able to minimize the distortions at the load or to allow a better utilization of the storage system by minimizing......Most power quality problems in distribution systems are related to voltage sags. Therefore, different solutions have been examined to compensate these sags to avoid production losses at sensitive loads. Dynamic voltage restorers (DVRs) have been proposed to provide higher power quality. Currently......, a system wide integration of DVRs is hampered because of their high cost, in particular, due to the expensive DC-link energy storage devices. The cost of these DC-link capacitors remains high because the DVR requires a minimum DC-link voltage to be able to operate and to compensate a sag. As a result, only...

  17. A Study on the Innovation Cost and Effectiveness Evaluation of Compensation Devices for Voltage Sags

    Science.gov (United States)

    Lang, Xuhui; Hara, Ryoichi; Kita, Hiroyuki; Tanaka, Eiichi; Hasegawa, Jun; Kubo, Hiroshi; Yonaga, Shigeru

    Due to the advancement of information technology and widespread use of power electronic devices in recent years, many customers in various fields have suffered from the voltage sag problem. In order to compensate voltage sags, sensitive loads have been primarily equipped with uninterruptible power supplies (UPS) by each consumer individually. Because consumers have many individual needs, this topic becomes an important problem to be considered by quality consultants in the electric utility industry. Based on this situation, we present the applications of UPS and dynamic voltage restorer (DVR) as compensation devices of voltage sags. By considering the need for power quality, we examine the cost-efficiency of both devices quantitatively. Simulations are carried out and the results are shown in this paper.

  18. Effect of welding current and voltage on the mechanical properties of wrought (6063 aluminium alloy

    Directory of Open Access Journals (Sweden)

    Oladele Isiaka Oluwole

    2010-06-01

    Full Text Available This work was carried out to investigate the effect of welded joints on the mechanical properties of wrought (6063 aluminium alloy. The study revealed the influence of current and voltage on the welded joint as well as the mechanical properties of the alloy. The alloy samples were welded together by metal inert gas welding process at varying values of current and voltage after which mechanical tests were performed on the welded samples. The microstructural examination of the various fusion zones obtained was carried out. Appreciable variations in the properties of the welded samples were observed due to changes in the microstructural features of the alloys. It was concluded that variation of current and voltage remarkably affect the mechanical properties of the wrought 6063 Aluminium alloy. As the voltage increases from 25 to 30 V, the ultimate tensile strengths and hardness values increases while the impact strengths decreases but the current did not show such trend.

  19. Design and Development of Autonomous High Voltage Driving System for DEAP Actuator in Radiator Thermostat

    DEFF Research Database (Denmark)

    Huang, Lina; Zhang, Zhe; Andersen, Michael A. E.

    2014-01-01

    make a high voltage capacitive load driving system to be necessary. The only energy source battery determines it needs to be an autonomous system. The detailed system specifications have been introduced and the corresponding system level design has been proposed. In addition, the detailed design......In radiator thermostat applications, DEAP (Dielectric Electro Active Polymer) actuator tends to be a good candidate to replace the conventional self-actuating or step motor based actuator due to its intrinsic advantages. The capacitive property and high voltage (HV) driving demand of DEAP actuator...... and implementation information has been provided as well, including the power and control stage inside the high voltage converter, the output voltage measurement circuit, the feedback control, etc. Finally, the experimental results have been provided to validate the capability and performance of the driving system....

  20. Repressing malic enzyme 1 redirects glucose metabolism,unbalances the redox state, and attenuates migratory and invasive abilities in nasopharyngeal carcinoma cell lines

    Institute of Scientific and Technical Information of China (English)

    Fang-Jing Zheng; Hao-Bin Ye; Man-Si Wu; Yi-Fan Lian; Chao-Nan Qian; Yi-Xin Zeng

    2012-01-01

    A large amount of nicotinamide adenine dinucleotide phosphate (NADPH) is required for fatty acid synthesis and maintenance of the redox state in cancer cells.Malic enzyme 1 (ME1)-dependent NADPH production is one of the three pathways that contribute to the formation of the cytosolic NADPH pool.ME1 is generally considered to be overexpressed in cancer cells to meet the high demand for increased de novo fatty acid synthesis.In the present study,we found that glucose induced higher ME1 activity and that repressing ME1 had a profound impact on glucose metabolism of nasopharyngeal carcinoma (NPC) cells.High incorporation of glucose and an enhancement of the pentose phosphate pathway were observed in ME1-repressed cells.However,there were no obvious changes in the other two pathways for glucose metabolism:glycolysis and oxidative phosphorylation.Interestingly,NADPH was decreased under lowglucose condition in ME1-repressed cells relative to wild-type cells,whereas no significant difference was observed under high-glucose condition.ME1-repressed cells had significantly decreased tolerance to lowglucose condition.Moreover,NADPH produced by ME1 was not only important for fatty acid synthesis but also essential for maintenance of the intracellular redox state and the protection of cells from oxidative stress.Furthermore,diminished migration and invasion were observed in ME1-repressed cells due to a reduced level of Snail protein.Collectively,these results suggest an essential role for ME1 in the production of cytosolic NADPH and maintenance of migratory and invasive abilities of NPC cells.

  1. Investigation of phase-wise voltage regulator control logics for compensating voltage deviations in an experimental low voltage network

    DEFF Research Database (Denmark)

    Hu, Junjie; Zecchino, Antonio; Marinelli, Mattia

    2016-01-01

    either locally or remotely. To evaluate and compare the control performances of the three control logics, all the tests use the same loading profiles. The experimental results indicate that the modified line compensation control can regulate voltage in a safe band in the case of various load......This paper investigates the control logics of an on-load tap-changer (OLTC) transformer by means of an experimental system validation. The experimental low-voltage unbalanced system consists of a decoupled single-phase OLTC transformer, a 75-metre 16 mm2 cable, a controllable single-phase resistive...... load and an electric vehicle, which has the vehicle-to-grid function. Three control logics of the OLTC transformer are described in the study. The three control logics are classified based on their control objectives and control inputs, which include network currents and voltages, and can be measured...

  2. Continuous-flow multi-pulse electroporation at low DC voltages by microfluidic flipping of the voltage space topology

    Science.gov (United States)

    Bhattacharjee, N.; Horowitz, L. F.; Folch, A.

    2016-10-01

    Concerns over biosafety, cost, and carrying capacity of viral vectors have accelerated research into physical techniques for gene delivery such as electroporation and mechanoporation. Advances in microfabrication have made it possible to create high electric fields over microscales, resulting in more efficient DNA delivery and higher cell viability. Continuous-flow microfluidic methods are typically more suitable for cellular therapies where a large number of cells need to be transfected under sterile conditions. However, the existing continuous-flow designs used to generate multiple pulses either require expensive peripherals such as high-voltage (>400 V) sources or function generators, or result in reduced cell viability due to the proximity of the cells to the electrodes. In this paper, we report a continuous-flow microfluidic device whose channel geometry reduces instrumentation demands and minimizes cellular toxicity. Our design can generate multiple pulses of high DC electric field strength using significantly lower voltages (15-60 V) than previous designs. The cells flow along a serpentine channel that repeatedly flips the cells between a cathode and an anode at high throughput. The cells must flow through a constriction each time they pass from an anode to a cathode, exposing them to high electric field strength for short durations of time (the "pulse-width"). A conductive biocompatible poly-aniline hydrogel network formed in situ is used to apply the DC voltage without bringing the metal electrodes close to the cells, further sheltering cells from the already low voltage electrodes. The device was used to electroporate multiple cell lines using electric field strengths between 700 and 800 V/cm with transfection efficiencies superior than previous flow-through designs.

  3. Modeling and Stress Analysis of Doubly-Fed Induction Generator during Grid Voltage Swell

    DEFF Research Database (Denmark)

    Zhou, Dao; Song, Yipeng; Blaabjerg, Frede

    2016-01-01

    The Doubly-Fed Induction Generator (DFIG) based wind turbine system is presently dominant in the wind turbine market. Due to heavy load switch-off and faults in the power grid, voltage swells may occur and this phenomenon is currently given sufficient insights. This paper starts to describe...... the transient voltage swell and its recovery. It is concluded that although both higher swell level and higher rotor speed cause higher rotor electromotive force, the doubly-fed induction generator can successfully ride through the grid fault due to the relatively small swell level required by the modern grid...

  4. High voltage testing for the MAJORANA DEMONSTRATOR

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Arnquist, I.J. [Pacific Northwest National Laboratory, Richland, WA (United States); Avignone, F.T. [Department of Physics and Astronomy, University of South Carolina, Columbia, SC (United States); Oak Ridge National Laboratory, Oak Ridge, TN (United States); Barabash, A.S. [National Research Center “Kurchatov Institute” Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Bertrand, F.E. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Bradley, A.W. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Brudanin, V. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Busch, M. [Department of Physics, Duke University, Durham, NC (United States); Triangle Universities Nuclear Laboratory, Durham, NC (United States); Buuck, M. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); Byram, D. [Department of Physics, University of South Dakota, Vermillion, SD (United States); Caldwell, A.S. [South Dakota School of Mines and Technology, Rapid City, SD (United States); Chan, Y-D. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Christofferson, C.D. [South Dakota School of Mines and Technology, Rapid City, SD (United States); Chu, P.-H. [Los Alamos National Laboratory, Los Alamos, NM (United States); Cuesta, C., E-mail: ccuesta@uw.edu [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); Detwiler, J.A.; Doe, P.J. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA (United States); and others

    2016-07-01

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in {sup 76}Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA DEMONSTRATOR. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA DEMONSTRATOR was characterized and the micro-discharge effects during the MAJORANA DEMONSTRATOR commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  5. Maximum permissible voltage of YBCO coated conductors

    Science.gov (United States)

    Wen, J.; Lin, B.; Sheng, J.; Xu, J.; Jin, Z.; Hong, Z.; Wang, D.; Zhou, H.; Shen, X.; Shen, C.

    2014-06-01

    Superconducting fault current limiter (SFCL) could reduce short circuit currents in electrical power system. One of the most important thing in developing SFCL is to find out the maximum permissible voltage of each limiting element. The maximum permissible voltage is defined as the maximum voltage per unit length at which the YBCO coated conductors (CC) do not suffer from critical current (Ic) degradation or burnout. In this research, the time of quenching process is changed and voltage is raised until the Ic degradation or burnout happens. YBCO coated conductors test in the experiment are from American superconductor (AMSC) and Shanghai Jiao Tong University (SJTU). Along with the quenching duration increasing, the maximum permissible voltage of CC decreases. When quenching duration is 100 ms, the maximum permissible of SJTU CC, 12 mm AMSC CC and 4 mm AMSC CC are 0.72 V/cm, 0.52 V/cm and 1.2 V/cm respectively. Based on the results of samples, the whole length of CCs used in the design of a SFCL can be determined.

  6. High voltage testing for the MAJORANA DEMONSTRATOR

    Science.gov (United States)

    Abgrall, N.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Bertrand, F. E.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Doe, P. J.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Fu, Z.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; Li, A.; MacMullin, J.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Orrell, J. L.; O'Shaughnessy, C.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, A. M.; Tedeschi, D.; Thompson, A.; Ton, K. T.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.

    2016-07-01

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA DEMONSTRATOR. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA DEMONSTRATOR was characterized and the micro-discharge effects during the MAJORANA DEMONSTRATOR commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  7. High voltage testing for the Majorana Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N.; Arnquist, Isaac J.; Avignone, F. T.; Barabash, A.; Bertrand, F.; Bradley, A. W.; Brudanin, V.; Busch, Matthew; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Yuen-Dat; Christofferson, C. D.; Chu, Pamela M.; Cuesta, C.; Detwiler, Jason A.; Doe, P. J.; Dunagan, C.; Efremenko, Yuri; Ejiri, H.; Elliott, S. R.; Fu, Z.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I.; Guiseppe, V. E.; Henning, R.; Hoppe, Eric W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K.; Kidd, M. F.; Konovalov, S.; Kouzes, Richard T.; Laferriere, Brian D.; Leon, Jonathan D.; Li, Alexander D.; MacMullin, J.; Martin, R. D.; Massarcyk, R.; Meijer, S. J.; Mertens, S.; Orrell, John L.; O' Shaughnessy, C.; Poon, Alan W.; Radford, D. C.; Rager, J.; Rielage, Keith; Robertson, R. G. H.; Romero Romo, M.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, Anne-Marie E.; Tedeschi, D.; Thompson, Andrew; Ton, K. T.; Trimble, J. E.; Varner, R. L.; Vasilyev, Sergey; Vetter, Kai; Vorren, Kris R.; White, Brandon R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, Chang-Hong; Yumatov, V.

    2016-07-01

    The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  8. Desbalanço redox: NADPH oxidase como um alvo terapêutico no manejo cardiovascular Desbalance redox: NADPH oxidasa como un objetivo terapéutico en el manejo cardiovascular Redox unbalance: NADPH oxidase as therapeutic target in blood pressure control

    Directory of Open Access Journals (Sweden)

    Luiza A. Rabêlo

    2010-05-01

    la mayor fuente de esas especies reactivas en la vasculatura. En condiciones fisiológicas, la formación y eliminación de esas sustancias aparecen balanceadas en la pared vascular. Durante el desbalance redox, sin embargo, hay un aumento en la actividad de la NADPH oxidasa y predominio de agentes prooxidantes, superando la capacidad de defensa orgánica antioxidante. Además de ello, tal hiperactividad enzimática reduce la biodisponibilidad del óxido nítrico, crucial para la vasodilatación y el mantenimiento de la función vascular normal. A pesar de que la NADPH oxidasa se relaciona directamente con la disfunción endotelial, fue primeramente descrita por su expresión en fagocitos, en los que su actividad enzimática determina la eficacia de los mecanismos de defensa orgánica contra patógenos. Las diferencias sutiles entre las unidades estructurales de las NADPH oxidasas, dependiendo del tipo celular que las expresa, pueden tener implicaciones terapéuticas, permitiendo la inhibición selectiva del desequilibrio redox inducido por la NADPH oxidasa, sin comprometer, con todo, su participación en las vías fisiológicas de señalización celular que garantizan la protección contra microorganismos.Several studies refer to reactive oxygen and nitrogen species (RONS as important agents in the pathogenesis of a number of heart diseases, including high blood pressure, arteriosclerosis and heart failure. Such species are highly bioactive molecules and a short life due chiefly to reduction of molecular oxygen. The enzyme complex of NADPH oxidase is the main source of these reactive species in vascular system. Under physiological conditions, formation and elimination of these substances seem balanced in vascular wall. During redox Unbalance, nonetheless, there is increase in NADPH oxidase activity and predominance of pro-oxidizing agents, surpassing the anti-oxidant capacity of the organism self-defense. Besides this, such enzyme hyperactivity reduces the

  9. Low-Voltage Consumption Coordination for Loss Minimization and Voltage Control

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for minimizing active power losses in low-voltage grids, by coordinating the consumption of electric vehicles and power generation from solar panels. We show that minimizing losses, also reduces voltage variations, and illustrate how this may be employed for increasing...... the number of electric vehicles and photovoltaic systems in the grid without violating grid constraints....

  10. Low-power low-voltage superior-order curvature corrected voltage reference

    Science.gov (United States)

    Popa, Cosmin

    2010-06-01

    A complementary metal oxide semiconductor (CMOS) voltage reference with a logarithmic curvature-correction will be presented. The first-order compensation is realised using an original offset voltage follower (OVF) block as a proportional to absolute temperature (PTAT) voltage generator, with the advantages of reducing the silicon area and of increasing accuracy by replacing matched resistors with matched transistors. The new logarithmic curvature-correction technique will be implemented using an asymmetric differential amplifier (ADA) block for compensating the logarithmic temperature dependent term from the first-order compensated voltage reference. In order to increase the circuit accuracy, an original temperature-dependent current generator will be designed for computing the exact type of the implemented curvature-correction. The relatively small complexity of the current squarer allows an important increasing of the circuit accuracy that could be achieved by increasing the current generator complexity. As a result of operating most of the MOS transistors in weak inversion, the original proposed voltage reference could be valuable for low-power applications. The circuit is implemented in 0.35 μm CMOS technology and consumes only 60μA for t = 25°C, being supplied at the minimal supply voltage V DD = 1.75V. The temperature coefficient of the reference voltage is 8.7 ppm/°C, while the line sensitivity is 0.75 mV/V for a supply voltage between 1.75 V and 7 V.

  11. Energy Storage Options for Voltage Support in Low-Voltage Grids with High Penetration of Photovoltaic

    DEFF Research Database (Denmark)

    Marra, Francesco; Tarek Fawzy, Y.; Bülo, Thorsten

    2012-01-01

    The generation of power by photovoltaic (PV) systems is constantly increasing in low-voltage (LV) distribution grids, in line with the European environmental targets. To cope with the effects on grid voltage profiles during high generation and low demand periods, new solutions need to be establis...

  12. Voltage-gated proton (H(v)1) channels, a singular voltage sensing domain.

    Science.gov (United States)

    Castillo, Karen; Pupo, Amaury; Baez-Nieto, David; Contreras, Gustavo F; Morera, Francisco J; Neely, Alan; Latorre, Ramon; Gonzalez, Carlos

    2015-11-14

    The main role of voltage-gated proton channels (Hv1) is to extrude protons from the intracellular milieu when, mediated by different cellular processes, the H(+) concentration increases. Hv1 are exquisitely selective for protons and their structure is homologous to the voltage sensing domain (VSD) of other voltage-gated ion channels like sodium, potassium, and calcium channels. In clear contrast to the classical voltage-dependent channels, Hv1 lacks a pore domain and thus permeation necessarily occurs through the voltage sensing domain. Hv1 channels are activated by depolarizing voltages, and increases in internal proton concentration. It has been proposed that local conformational changes of the transmembrane segment S4, driven by depolarization, trigger the molecular rearrangements that open Hv1. However, it is still unclear how the electromechanical coupling is achieved between the VSD and the potential pore, allowing the proton flux from the intracellular to the extracellular side. Here we provide a revised view of voltage activation in Hv1 channels, offering a comparative scenario with other voltage sensing channels domains.

  13. P Voltage Control of DFIG with Two-Mass-Shaft Turbine Model Under Utility Voltage Disturbance

    Directory of Open Access Journals (Sweden)

    Hengameh Kojooyan Jafari

    2016-06-01

    Full Text Available Doubly fed induction generators as a variable speed induction generators are applied instead of other electric machines in wind power plants to be connected to the grid with flexible controllers. Nowadays one of the most important subjects in wind farms is control of output power delivered to the grid under utility disturbance. In this paper, a doubly-fed induction generator with external rotor resistance and power converters model as an external voltage source having an adjustable phase and amplitude with an ordinary turbine connected to one mass shaft model and also two mass shaft model, is used and controlled by a P voltage controller to control the output active power for typical high and low wind speeds under two conditions of utility disturbance; while time of disturbance is not too long to change the domain of external rotor voltage source and also while time is long and the domain of external rotor voltage decreases.Simulation results show that P voltage controller can control output active power under 27% stator voltage drop down for typical low wind speed and 11% stator voltage drop down for typical high wind speed in long time disturbance while 80% of rotor external voltage domain drops down under short time utility disturbance.

  14. Measurement of a power system nominal voltage, frequency and voltage flicker parameters

    Energy Technology Data Exchange (ETDEWEB)

    Alkandari, A.M. [College of Technological Studies, Electrical Engineering Technology Department, Shwiekh (Kuwait); Soliman, S.A. [Electrical Power and Machines Department, Misr University for Science and Technology, Cairo (Egypt)

    2009-09-15

    We present, in this paper, an approach for identifying the frequency and amplitude of voltage flicker signal that imposed on the nominal voltage signal, as well as the amplitude and frequency of the nominal signal itself. The proposed algorithm performs the estimation in two steps; in the first step the original voltage signal is shifted forward and backward by an integer number of sample, one sample in this paper. The new generated signals from such a shift together with the original one is used to estimate the amplitude of the original signal voltage that composed of the nominal voltage and flicker voltage. The average of this amplitude gives the amplitude of the nominal voltage; this amplitude is subtracted from the original identified signal amplitude to obtain the samples of the flicker voltage. In the second step, the argument of the signal is calculated by simply dividing the magnitude of signal sample with the estimated amplitude in the first step. Calculating the arccosine of the argument, the frequency of the nominal signal as well as the phase angle can be computing using the least error square estimation algorithm. Simulation examples are given within the text to show the features of the proposed approach. (author)

  15. Analysis of Voltage Support by Electric Vehicles and Photovoltaic in a Real Danish Low Voltage Network

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia; Juul Møller, René

    2014-01-01

    of incorporating electric vehicles (EVs) in a low voltage distribution network with high penetration of photovoltaic installations (PVs), and focuses on analysing potential voltage support functions from EVs and PVs. In addition, the paper evaluates the benefits that reactive power control may provide...

  16. 30 CFR 75.804 - Underground high-voltage cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage cables. 75.804 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.804 Underground high-voltage cables. (a) Underground high-voltage cables used in resistance...

  17. 46 CFR 129.326 - Dual-voltage generators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at...

  18. 30 CFR 77.810 - High-voltage equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage equipment; grounding. 77.810... COAL MINES Surface High-Voltage Distribution § 77.810 High-voltage equipment; grounding. Frames, supporting structures, and enclosures of stationary, portable, or mobile high-voltage equipment shall...

  19. 47 CFR 17.54 - Rated lamp voltage.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Rated lamp voltage. 17.54 Section 17.54... voltage. To insure the necessary lumen output by obstruction lights, the rated voltage of incandescent lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket...

  20. Note: Galvanic isolated voltage source using a single photodiode.

    Science.gov (United States)

    Stoican, O S

    2010-04-01

    A galvanic isolated voltage source able to provide several volts by using a single photodiode is described. A pulse-modulated laser beam is sent to a photodiode. By using a step-up transformer the amplitude of the variable voltage generated by the photodiode is increased. Adding a rectifier cell the variable voltage is converted back into a dc voltage.

  1. Voltage control in active, intelligent low-voltage distribution networks; Spannungshaltung in aktiven, intelligenten Niederspannungsnetzen

    Energy Technology Data Exchange (ETDEWEB)

    Buelo, Thorsten; Mende, Denis [SMA Solar Technology AG, Niestetal (Germany); Geibel, Dominik [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik (IWES), Kassel (Germany)] [and others

    2012-07-01

    This paper describes approaches for the voltage control in low-voltage distribution networks with a high share of distributed energy resources (DER). Taken into account are devices such as distribution transformers with on-load tap changer (OLTC), photovoltaic-inverters with reactive power capability and electronic voltage controllers (EVC). After a short description regarding voltage control, the devices and selected system concepts as well as the advantages and disadvantages of the different devices are described. Finally, the system-concepts are compared using the example of a real low voltage network, taking into account the possible increase of hosting capacity of the network, curtailing losses and the amount of reactive energy to be provided. (orig.)

  2. Low Voltage Analog Circuit Design Based on the Flipped Voltage Follower

    Directory of Open Access Journals (Sweden)

    Neeraj Yadav

    2012-03-01

    Full Text Available The desire for portability of electronics equipment generated a need for low power system in battery products like hearing aids, implantable cardiac pacemakers, cell phones and hand held multimedia terminals. Low voltage analog circuit design differs considerably from those of high voltage analog circuit design. This paper present the basic cell knows as “flipped voltage follower” for low voltage/ low power operation. The detailed classification of basic topologies derived from the FVF cell is presented and there is a low voltage current mirror based on FVF cell has been presented. All the Circuit has been simulated using Hspice tool 0.18µm CMOS Technology. Different quality factors such as frequency response, power consumption are considered. A compression also made between previous current mirror and new designed current mirror. The layout of the current mirror has been also designed using Cadence tool.

  3. Voltage and frequency control in the Islanded portion of the CIGRE Low Voltage distribution network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak, Claus Leth; Buriro, Ehsan Ali

    2017-01-01

    imbalance in the islanded MG. The voltage and the frequency of the islanded MG can be restored to the permissible limits if the desired/exceeded amount of active and reactive power is injected/absorbed by the locally available sources in islanded MG. This paper proposes the control strategy which can...... by providing some ancillary services. The main focus of this paper is about the development of a control system for the islanded MG, the selection of Voltage-Frequency controller for the most suitable DG unit of the Low Voltage test network and the control of voltage and frequency in islanding condition. Under...... compensate the problems of the voltage and the frequency deviations in the islanded MG. The selection of the VF controller for the most suitable DG unit of the LV test network is also presented in this paper and effectiveness of the controllers is verified by presenting simulation results...

  4. A dynamic voltage restorer (DVR) with selective harmonic compensation at medium voltage level

    DEFF Research Database (Denmark)

    Newman, M.J.; Holmes, D.G.; Nielsen, J.G.;

    2005-01-01

    -state power through the DVR, the increased losses, and the low modulation depths at which the scheme must operate to achieve acceptable harmonic compensation performance. This paper presents a selective harmonic feedback control strategy that can be easily added to medium-voltage DVR systems to provide...... be advantageous if the series-connected inverter of a DVR could also be used to compensate for any steady-state load voltage harmonics, since this would increase the power quality "value-added" benefits to the grid system. However, before this can be done, consideration must be given to the control of steady...... voltage harmonic compensation capabilities with minimal effect on the sag compensation performance of the basic DVR. The proposed controller has been experimentally verified on a medium-voltage (10 kV) three-phase DVR prototype under a range of conditions, including distorted supply voltages, nonlinear...

  5. FGMOS Based Voltage-Controlled Grounded Resistor

    Directory of Open Access Journals (Sweden)

    R. Pandey

    2010-09-01

    Full Text Available This paper proposes a new floating gate MOSFET (FGMOS based voltage-controlled grounded resistor. In the proposed circuit FGMOS operating in the ohmic region is linearized by another conventional MOSFET operating in the saturation region. The major advantages of FGMOS based voltage-controlled grounded resistor (FGVCGR are simplicity, low total harmonic distortion (THD, and low power consumption. A simple application of this FGVCGR as a tunable high-pass filter is also suggested. The proposed circuits operate at the supply voltages of +/-0.75 V. The circuits are designed and simulated using SPICE in 0.25-µm CMOS technology. The simulation results of FGVCGR demonstrate a THD of 0.28% for the input signal 0.32 Vpp at 45 kHz, and a maximum power consumption of 254 µW.

  6. Voltage stability, bifurcation parameters and continuation methods

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado, F.L. [Wisconsin Univ., Madison, WI (United States)

    1994-12-31

    This paper considers the importance of the choice of bifurcation parameter in the determination of the voltage stability limit and the maximum power load ability of a system. When the bifurcation parameter is power demand, the two limits are equivalent. However, when other types of load models and bifurcation parameters are considered, the two concepts differ. The continuation method is considered as a method for determination of voltage stability margins. Three variants of the continuation method are described: the continuation parameter is the bifurcation parameter the continuation parameter is initially the bifurcation parameter, but is free to change, and the continuation parameter is a new `arc length` parameter. Implementations of voltage stability software using continuation methods are described. (author) 23 refs., 9 figs.

  7. Semisupervised Community Detection by Voltage Drops

    Directory of Open Access Journals (Sweden)

    Min Ji

    2016-01-01

    Full Text Available Many applications show that semisupervised community detection is one of the important topics and has attracted considerable attention in the study of complex network. In this paper, based on notion of voltage drops and discrete potential theory, a simple and fast semisupervised community detection algorithm is proposed. The label propagation through discrete potential transmission is accomplished by using voltage drops. The complexity of the proposal is OV+E for the sparse network with V vertices and E edges. The obtained voltage value of a vertex can be reflected clearly in the relationship between the vertex and community. The experimental results on four real networks and three benchmarks indicate that the proposed algorithm is effective and flexible. Furthermore, this algorithm is easily applied to graph-based machine learning methods.

  8. Intermediate state trapping of a voltage sensor

    DEFF Research Database (Denmark)

    Lacroix, Jérôme J; Pless, Stephan Alexander; Maragliano, Luca

    2012-01-01

    Voltage sensor domains (VSDs) regulate ion channels and enzymes by undergoing conformational changes depending on membrane electrical signals. The molecular mechanisms underlying the VSD transitions are not fully understood. Here, we show that some mutations of I241 in the S1 segment of the Shaker...... Kv channel positively shift the voltage dependence of the VSD movement and alter the functional coupling between VSD and pore domains. Among the I241 mutants, I241W immobilized the VSD movement during activation and deactivation, approximately halfway between the resting and active states......, and drastically shifted the voltage activation of the ionic conductance. This phenotype, which is consistent with a stabilization of an intermediate VSD conformation by the I241W mutation, was diminished by the charge-conserving R2K mutation but not by the charge-neutralizing R2Q mutation. Interestingly, most...

  9. Planar multijunction high voltage solar cells

    Science.gov (United States)

    Evans, J. C., Jr.; Chai, A. T.; Goradia, C.

    1980-01-01

    Technical considerations, preliminary results, and fabrication details are discussed for a family of high-voltage planar multi-junction (PMJ) solar cells which combine the attractive features of planar cells with conventional or interdigitated back contacts and the vertical multijunction (VMJ) solar cell. The PMJ solar cell is internally divided into many voltage-generating regions, called unit cells, which are internally connected in series. The key to obtaining reasonable performance from this device was the separation of top surface field regions over each active unit cell. Using existing solar cell fabricating methods, output voltages in excess of 20 volts per linear centimeter are possible. Analysis of the new device is complex, and numerous geometries are being studied which should provide substantial benefits in both normal sunlight usage as well as with concentrators.

  10. Comparison of Algorithms for Control of Loads for Voltage Regulation

    DEFF Research Database (Denmark)

    Douglass, Philip James; Han, Xue; You, Shi

    2014-01-01

    Autonomous flexible loads can be utilized to regulate voltag e on low voltage feeders. This paper compares two algorithms for controllin g loads: a simple voltage droop, where load power consumption is a varied in proportio n to RMS voltage; and a normalized relative voltage droop, which modifies...... the simpl e voltage droop by subtracting the mean voltage value at the bus and dividing by the standard deviation. These two controllers are applied to hot water heaters simul ated in a simple residential feeder. The simulation results show that both controllers r educe the frequency of undervoltage events...

  11. Experimental validation of a high voltage pulse measurement method.

    Energy Technology Data Exchange (ETDEWEB)

    Cular, Stefan; Patel, Nishant Bhupendra; Branch, Darren W.

    2013-09-01

    This report describes X-cut lithium niobates (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensors U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

  12. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  13. Voltage control of DC islanded microgrids

    DEFF Research Database (Denmark)

    Tucci, Michele; Riverso, Stefano; Quintero, Juan Carlos Vasquez

    2015-01-01

    We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC) of the correspond......We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC...

  14. Due process traditionalism.

    Science.gov (United States)

    Sunstein, Cass R

    2008-06-01

    In important cases, the Supreme Court has limited the scope of "substantive due process" by reference to tradition, but it has yet to explain why it has done so. Due process traditionalism might be defended in several distinctive ways. The most ambitious defense draws on a set of ideas associated with Edmund Burke and Friedrich Hayek, who suggested that traditions have special credentials by virtue of their acceptance by many minds. But this defense runs into three problems. Those who have participated in a tradition may not have accepted any relevant proposition; they might suffer from a systematic bias; and they might have joined a cascade. An alternative defense sees due process traditionalism as a second-best substitute for two preferable alternatives: a purely procedural approach to the Due Process Clause, and an approach that gives legislatures the benefit of every reasonable doubt. But it is not clear that in these domains, the first-best approaches are especially attractive; and even if they are, the second-best may be an unacceptably crude substitute. The most plausible defense of due process traditionalism operates on rule-consequentialist grounds, with the suggestion that even if traditions are not great, they are often good, and judges do best if they defer to traditions rather than attempting to specify the content of "liberty" on their own. But the rule-consequentialist defense depends on controversial and probably false assumptions about the likely goodness of traditions and the institutional incapacities of judges.

  15. Flow-driven voltage generation in carbon nanotubes

    Indian Academy of Sciences (India)

    A K Sood; S Ghosh; Anindya Das

    2005-10-01

    The flow of various liquids and gases over single-walled carbon nanotube bundles induces an electrical signal (voltage/current) in the sample along the direction of the flow. The electrical response generated by the flow of liquids is found to be logarithmic in the flow speed over a wide range. In contrast, voltage generated by the flow of gas is quadratically dependent on the gas flow velocity. It was found that the underlying physics for the generation of electrical signals by liquids and gases are different. For the liquid, the Coulombic interaction between the ions in the liquid and the charge carriers in the nanotube plays a key role while electrical signal generation due to gas flow is due to an interplay of Bernoulli's principle and Seebeck effect. Unlike the liquid case which is specific to the nanotubes, the gas flow effect can be seen for a variety of solids ranging from single and multi-walled carbon nanotubes, graphite and doped semiconductors.

  16. Low voltage electron multiplying CCD in a CMOS process

    Science.gov (United States)

    Dunford, Alice; Stefanov, Konstantin; Holland, Andrew

    2016-07-01

    Low light level and high-speed image sensors as required for space applications can suffer from a decrease in the signal to noise ratio (SNR) due to the photon-starved environment and limitations of the sensor's readout noise. The SNR can be increased by the implementation of Time Delay Integration (TDI) as it allows photoelectrons from multiple exposures to be summed in the charge domain with no added noise. Electron Multiplication (EM) can further improve the SNR and lead to an increase in device performance. However, both techniques have traditionally been confined to Charge Coupled Devices (CCD) due to the efficient charge transfer required. With the increase in demand for CMOS sensors with equivalent or superior functionality and performance, this paper presents findings from the characterisation of a low voltage EMCCD in a CMOS process using advanced design features to increase the electron multiplying gain. By using the CMOS process, it is possible to increase chip integration and functionality and achieve higher readout speeds and reduced pixel size. The presented characterisation results include analysis of the photon transfer curve, the dark current, the electron multiplying gain and analysis of the parameters' dependence on temperature and operating voltage.

  17. Unified Power Quality Conditioner for voltage and current compensation

    OpenAIRE

    P.Annapandi; Dr.M.Rajaram

    2012-01-01

    This paper deals with a Unified Power Quality Conditioner (UPQC) for load balancing, power factorcorrection, voltage regulation, voltage and current harmonics mitigation, mitigation of voltage sag, swelland voltage dip in a three-phase three-wire distribution system for different combinations of linear and nonlinear loads.The unified power quality conditioner (UPQC) is a combination of back to back connected shunt and series active power filters (APFs) to a common DC link voltage, which compe...

  18. Onycholysis due to trauma

    Directory of Open Access Journals (Sweden)

    Patricia Chang

    2014-04-01

    Full Text Available Female patient, 35 years old who came to the private office due to discoloration of her left thumbnail and little pain since 1 month ago. Clinical examination shows nail disease on her left thumbnail with onycholysis and dyschromia, dermatoscopy showed white-yellowish discoloration (Fig. 1A, B. The rest of the clinical examination was normal. Patient use to using acrylic nails since 2 years ago and denied some trauma at the nail. The diagnosis of onycholysis due to trauma was done and recommended her not to use acrylic nail, maintain the nail short and avoid wetness.

  19. A dual voltage control strategy for single-phase PWM converters with power decoupling function

    DEFF Research Database (Denmark)

    Tang, Yi; Qin, Zian; Blaabjerg, Frede

    2014-01-01

    The inherent double line ripple power in singlephase systems is adverse to the converter performance, e.g. limited lifetime due to the requirement of large electrolytic capacitors and low voltage control bandwidth due to harmonic disturbance. In this paper, an active converter topology based...... on a symmetrical half bridge circuit is proposed to decouple the ripple power so that balanced instantaneous power flow is assured between source and load, and the required dc-link capacitance can be dramatically reduced. For proper closed-loop regulation, the small signal modeling of the proposed system...... is presented, and a dual voltage control strategy is then proposed, which comprises one voltage loop implemented in the synchronous reference frame for active power balancing, and another one implemented in the harmonic reference frame for ripple power compensation. Special attention is given to the bandwidth...

  20. A dual voltage control strategy for single-phase PWM converters with power decoupling function

    DEFF Research Database (Denmark)

    Tang, Yi; Qin, Zian; Blaabjerg, Frede

    2015-01-01

    converter topology based on a symmetrical half bridge circuit is proposed to decouple the ripple power so that balanced instantaneous power flow is assured between source and load, and the required dc-link capacitance can be dramatically reduced. For proper closed-loop regulation, the small signal modeling......The inherent double line ripple power in single-phase systems is adverse to the performance of power electronics converters, e.g. limited lifetime due to the requirement of large electrolytic capacitors and low voltage control bandwidth due to harmonic disturbance. In this paper, an active...... of the proposed system is presented, and a dual voltage control strategy is then proposed, which comprises one voltage loop implemented in the synchronous reference frame for active power balancing, and another one implemented in the stationary reference frame for ripple power compensation. Special attention...

  1. Low-Voltage Ultra-Low-Power Current Conveyor Based on Quasi-Floating Gate Transistors

    Directory of Open Access Journals (Sweden)

    F. Khateb

    2012-06-01

    Full Text Available The field of low-voltage low-power CMOS technology has grown rapidly in recent years; it is an essential prerequisite particularly for portable electronic equipment and implantable medical devices due to its influence on battery lifetime. Recently, significant improvements in implementing circuits working in the low-voltage low-power area have been achieved, but circuit designers face severe challenges when trying to improve or even maintain the circuit performance with reduced supply voltage. In this paper, a low-voltage ultra-low-power current conveyor second generation CCII based on quasi-floating gate transistors is presented. The proposed circuit operates at a very low supply voltage of only ±0.4 V with rail-to-rail voltage swing capability and a total quiescent power consumption of mere 9.5 µW. Further, the proposed circuit is not only able to process the AC signal as it's usual at quasi-floating gate transistors but also the DC which extends the applicability of the proposed circuit. In conclusion, an application example of the current-mode quadrature oscillator is presented. PSpice simulation results using the 0.18 µm TSMC CMOS technology are included to confirm the attractive properties of the proposed circuit.

  2. High voltage trapping effects in GaN-based metal-insulator-semiconductor transistors

    Science.gov (United States)

    Meneghesso, Gaudenzio; Meneghini, Matteo; Silvestri, Riccardo; Vanmeerbeek, Piet; Moens, Peter; Zanoni, Enrico

    2016-01-01

    This paper presents an analysis of the high voltage trapping processes that take place in high-electron mobility transistors based on GaN, with a metal-insulator-semiconductor (MIS) structure. The study is based on combined pulsed and transient measurements, carried out with trapping voltages in the range from 50 to 500 V. The results indicate that: (i) dynamic Ron is maximum for trapping voltages between 200 and 300 V, and decreases for higher voltage levels; (ii) Ron-transient measurements reveal the presence of a dominant trap with activation energy Ea1 = 0.93 eV and of a second trap with activation energy equal to Ea2 = 0.61 eV; (iii) the deep level transient spectroscopy (DLTS) signal associated to trap Ea1 is completely suppressed for high trapping voltages (VDS = 500 V). The results are interpreted by considering that the trap Ea1 is located in the buffer, and originates from CN defects. The exposure to high drain voltages may favor the depletion of such traps, due to a field-assisted de-trapping process or to the presence of vertical leakage paths.

  3. Voltage Control Scheme with Distributed Generation and Grid Connected Converter in a DC Microgrid

    Directory of Open Access Journals (Sweden)

    Jong-Chan Choi

    2014-10-01

    Full Text Available Direct Current (DC microgrids are expected to become larger due to the rapid growth of DC energy sources and power loads. As the scale of the system expends, the importance of voltage control will be increased to operate power systems stably. Many studies have been performed on voltage control methods in a DC microgrid, but most of them focused only on a small scale microgrid, such as a building microgrid. Therefore, a new control method is needed for a middle or large scale DC microgrid. This paper analyzes voltage drop problems in a large DC microgrid and proposes a cooperative voltage control scheme with a distributed generator (DG and a grid connected converter (GCC. For the voltage control with DGs, their location and capacity should be considered for economic operation in the systems. Accordingly, an optimal DG allocation algorithm is proposed to minimize the capacity of a DG for voltage control in DC microgrids. The proposed methods are verified with typical load types by a simulation using MATLAB and PSCAD/EMTDC.

  4. Performance Analysis of Phase Controlled Unidirectional and Bidirectional AC Voltage Controllers

    Directory of Open Access Journals (Sweden)

    Abdul Sattar Larik

    2011-01-01

    Full Text Available AC voltage controllers are used to vary the output ac voltage from a fixed ac input source. They are also commonly called ac voltage regulators or ac choppers. The output voltage is either controlled by PAC (Phase Angle Control method or on-off control method. Due to various advantages of ac voltage controllers, such as high efficiency, simplicity, low cost and ability to control large amount of power they efficiently control the speed of ac motors, light dimming and industrial heating, etc. These converters are variable structure systems and generate harmonics during the operation which will affect the power quality when connected to system network. During the last couple of years, a number of new semiconductor devices and various power electronic converters has been introduced. Accordingly the subject of harmonics and its problems are of great concern to power industry and customers. In this research work, initially the simulation models of single phase unidirectional and bidirectional ac voltage controllers were developed by using MATLAB software. The harmonics of these models are investigated by simulation. In the end, the harmonics were also analyzed experimentally. The simulated as well as experimental results are presented.

  5. Investigation of the built-in voltage in organic pin solar cells using electroabsorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Siebert-Henze, Ellen; Tress, Wolfgang; Lyssenko, Vadim G.; Hintschich, Susanne I.; Leo, Karl; Riede, Moritz [Institut fuer Angewandte Photophysik, Dresden (Germany)

    2011-07-01

    The built-in voltage of small molecule organic solar cells based on the pin concept is investigated. We use the method of electroabsorption spectroscopy whose principle is the detection of absorption changes due to electrical excitation (Stark effect). A voltage consisting of a DC and an AC part is applied to the sample and the change in absorption is detected using a lock-in amplifier. The variation of the applied DC voltage modifies the DC field across the sample leading to a linear change of the corresponding Stark signal. This supplies information about the built-in voltage of the device which is determined for different combinations of donor materials and hole transport materials (MeO-TPD, BPAPF, alpha-NPD, and ZnPc). In addition, the doping concentration of the hole transport layer is modified and the influence of the consequential change of the work function on the built-in voltage is examined. It is shown that both the short-circuit current as well as the fill factor increase for larger built-in voltages.

  6. Genetic Algorithm-Based Artificial Neural Network for Voltage Stability Assessment

    Directory of Open Access Journals (Sweden)

    Garima Singh

    2011-01-01

    Full Text Available With the emerging trend of restructuring in the electric power industry, many transmission lines have been forced to operate at almost their full capacities worldwide. Due to this, more incidents of voltage instability and collapse are being observed throughout the world leading to major system breakdowns. To avoid these undesirable incidents, a fast and accurate estimation of voltage stability margin is required. In this paper, genetic algorithm based back propagation neural network (GABPNN has been proposed for voltage stability margin estimation which is an indication of the power system's proximity to voltage collapse. The proposed approach utilizes a hybrid algorithm that integrates genetic algorithm and the back propagation neural network. The proposed algorithm aims to combine the capacity of GAs in avoiding local minima and at the same time fast execution of the BP algorithm. Input features for GABPNN are selected on the basis of angular distance-based clustering technique. The performance of the proposed GABPNN approach has been compared with the most commonly used gradient based BP neural network by estimating the voltage stability margin at different loading conditions in 6-bus and IEEE 30-bus system. GA based neural network learns faster, at the same time it provides more accurate voltage stability margin estimation as compared to that based on BP algorithm. It is found to be suitable for online applications in energy management systems.

  7. Technical Due Diligence

    DEFF Research Database (Denmark)

    Jensen, Per Anker; Varano, Mattia

    2011-01-01

    Technical Due Diligence (TDD) as an evaluation of the performance of constructed facilities has become an important new field of practice for consultants. Before the financial crisis started in autumn 2008 it represented the fastest growing activity in some consulting companies. TDD is mostly car...

  8. Exploration of genetically encoded voltage indicators based on a chimeric voltage sensing domain

    Directory of Open Access Journals (Sweden)

    Yukiko eMishina

    2014-09-01

    Full Text Available Deciphering how the brain generates cognitive function from patterns of electrical signals is one of the ultimate challenges in neuroscience. To this end, it would be highly desirable to monitor the activities of very large numbers of neurons while an animal engages in complex behaviours. Optical imaging of electrical activity using genetically encoded voltage indicators (GEVIs has the potential to meet this challenge. Currently prevalent GEVIs are based on the voltage-sensitive fluorescent protein (VSFP prototypical design or on the voltage dependent state transitions of microbial opsins.We recently introduced a new VSFP design in which the voltage-sensing domain (VSD is sandwiched between a FRET pair of fluorescent proteins (termed VSFP-Butterflies and also demonstrated a series of chimeric VSD in which portions of the VSD of Ciona intestinalis voltage-sensitive phosphatase (Ci-VSP are substituted by homologous portions of a voltage-gated potassium channel subunit. These chimeric VSD had faster sensing kinetics than that of the native Ci-VSD. Here, we describe a new set of VSFPs that combine chimeric VSD with the Butterfly structure. We show that these chimeric VSFP-Butterflies can report membrane voltage oscillations of up to 200 Hz in cultured cells and report sensory evoked cortical population responses in living mice. This class of GEVIs may be suitable for imaging of brain rhythms in behaving mammalians.

  9. Design of Neutral-Point Voltage Controller of a Three-level NPC Inverter with Small DC-Link Capacitors

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, S.

    2013-01-01

    A Neutral-Point-Clamped (NPC) three-level inverter with small dc-link capacitors is presented in this paper. The inverter requires zero average neutral-point current for stable neutral-point voltage. The small dc-link capacitors may not maintain capacitor voltage balance, even with zero neutral-point...... current. This may happen due to nonlinearities present in the circuit. This requires a fast control of the neutral-point voltage. A simple carrier based modulation strategy which allows modeling of the neutral-point voltage dynamics as a continuous function of power drawn from the inverter is proposed....... This continuous model shows that the neutral-point current is proportional to the power drawn from the inverter, and it enables the use of well established classical control theory for the neutral-point voltage controller design. A simple PI (proportional integral) controller is designed for the neutral-point...

  10. SEMICONDUCTOR DEVICES: EMP injection damage effects of a bipolar transistor and its relationship between the injecting voltage and energy

    Science.gov (United States)

    Xiaowen, Xi; Changchun, Chai; Xingrong, Ren; Yintang, Yang; Bing, Zhang; Xiao, Hong

    2010-04-01

    The response of a bipolar transistor (BJT) under a square-wave electromagnetic pulse (EMP) with different injecting voltages is investigated. Adopting the curve fitting method, the relationship between the burnout time, the damage energy and the injecting voltage is obtained. Research shows that the damage energy is not a constant value, but changes with the injecting voltage level. By use of the device simulator Medici, the internal behavior of the burned device is analyzed. Simulation results indicate that the variation of the damage energy with injecting voltage is caused by the distribution change of hot spot position under different injection levels. Therefore, the traditional way to evaluate the trade-off between the burnout time and the injecting voltage is not comprehensive due to the variation of the damage energy.

  11. Loading Analysis of Modular Multi-level Converter for Offshore High-voltage DC Application under Various Grid Faults

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang;

    2016-01-01

    The modular multi-level converter has become an interesting candidate in high-voltage DC systems due to its higher voltage levels and modular construction. Low-voltage ride-through is an important grid requirement for modular multi-level converter–high-voltage DC since not only causes control...... challenges but may also result in overstressed components for the modular multi-level converter. However, the thermal loading of the modular multi-level converter under various grid faults has not yet been clarified. In this article, the power loss and thermal performance of the modular multi-level converter...... during grid voltage dips are studied. The impacts of two typical grid faults to the modular multi-level converter in terms of operating and loading conditions are analytically researched and simulated. It has been found that the operating and loading conditions of the modular multi-level converter under...

  12. EMP injection damage effects of a bipolar transistor and its relationship between the injecting voltage and energy

    Energy Technology Data Exchange (ETDEWEB)

    Xi Xiaowen; Chai Changchun; Ren Xingrong; Yang Yintang; Zhang Bing; Hong Xiao, E-mail: xixiaowen523103@163.co [Key Laboratory of Ministry of Education for Wide Band-Gap Semiconductor Materials and Devices, School of Microelectronics, Xidian University, Xi' an 710071 (China)

    2010-04-15

    The response of a bipolar transistor (BJT) under a square-wave electromagnetic pulse (EMP) with different injecting voltages is investigated. Adopting the curve fitting method, the relationship between the burnout time, the damage energy and the injecting voltage is obtained. Research shows that the damage energy is not a constant value, but changes with the injecting voltage level. By use of the device simulator Medici, the internal behavior of the burned device is analyzed. Simulation results indicate that the variation of the damage energy with injecting voltage is caused by the distribution change of hot spot position under different injection levels. Therefore, the traditional way to evaluate the trade-off between the burnout time and the injecting voltage is not comprehensive due to the variation of the damage energy. (semiconductor devices)

  13. Dual voltage power supply with 48 volt

    Energy Technology Data Exchange (ETDEWEB)

    Froeschl, Joachim; Proebstle, Hartmut; Sirch, Ottmar [BMW Group, Muenchen (Germany)

    2012-11-01

    Automotive electrics/electronics have just reached a period of tremendous change. High voltage systems for Hybrid, Plug-In Hybrid or Battery Electric Vehicles with high power electric motors, high energy accumulators and electric climate compressors will be introduced in order to achieve the challenging targets for CO{sub 2} emissions and energy efficiency and to anticipate the mobility of the future. Additionally, innovations and the continuous increase of functionality for comfort, safety, driver assistance and infotainment systems require more and more electrical power of the vehicle power supply at all. On the one hand side electrified vehicles will certainly achieve a significant market share, on the other hand side they will increase the pressure to conventional vehicles with combustion engines for fuel consumption and CO{sub 2} emissions. These vehicles will be enabled to keep their competitiveness by new functions and the optimization of their electric systems. A dual voltage power supply with 48 Volt and 12 Volt will be one of the key technologies to realize these requirements. The power capability of the existing 12 Volt power supply has reached its limits. Further potentials can only be admitted by the introduction of 48 Volt. For this reason the car manufacturers Audi, BMW, Daimler, Porsche and Volkswagen started very early on this item and developed a common specification of the new voltage range. Now, it is necessary to identify the probable systems at this voltage range and to start the developments. (orig.)

  14. High voltage pulse generator. [Patent application

    Science.gov (United States)

    Fasching, G.E.

    1975-06-12

    An improved high-voltage pulse generator is described which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of the first rectifier connected between the first and second capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. The output voltage can be readily increased by adding additional charging networks. The circuit allows the peak level of the output to be easily varied over a wide range by using a variable autotransformer in the charging circuit.

  15. The VELO High Voltage System Control Software

    CERN Document Server

    Rakotomiaramanana, B; Eklund, L; De Capua, S

    2010-01-01

    This note describes the VELO high voltage control software. The implementation of its structure as a PVSS Finite State Machine is emphasized. The main error conditions that may occur during operation is also discussed. The VELO HV software conforms to the specification of the VELO.

  16. Alternating current breakdown voltage of ice electret

    Science.gov (United States)

    Oshika, Y.; Tsuchiya, Y.; Okumura, T.; Muramoto, Y.

    2017-09-01

    Ice has low environmental impact. Our research objectives are to study the availability of ice as a dielectric insulating material at cryogenic temperatures. We focus on ferroelectric ice (iceXI) at cryogenic temperatures. The properties of iceXI, including its formation, are not clear. We attempted to obtain the polarized ice that was similar to iceXI under the applied voltage and cooling to 77 K. The polarized ice have a wide range of engineering applications as electronic materials at cryogenic temperatures. This polarized ice is called ice electret. The structural difference between ice electret and normal ice is only the positions of protons. The effects of the proton arrangement on the breakdown voltage of ice electret were shown because electrical properties are influenced by the structure of ice. We observed an alternating current (ac) breakdown voltage of ice electret and normal ice at 77 K. The mean and minimum ac breakdown voltage values of ice electret were higher than those of normal ice. We considered that the electrically weak part of the normal ice was improved by applied a direct electric field.

  17. Stray voltage zapping cows, pigs in Quebec

    Energy Technology Data Exchange (ETDEWEB)

    1988-05-18

    A power-supply malfunction is giving farm animals in Quebec a shock every time they eat or drink from metal troughs, making them nervous, lowering production, and stunting growth. In 2 years of negotiation with Hydro-Quebec, the utility has refused to correct the problem known as stray voltage. The shocks measure about 10 volts. It has been estimated the average Quebec dairy farmer with 40 cows is losing $15,000 to $20,000/y in reduced milk production. About 4,000 of the 23,000 Quebec pig and dairy farms are bothered by stray voltage. Hydro-Quebec has been asked to install filters that would reduce the problem; however, Hydro-Quebec attributes the stray voltage to the farmers' own equipment. A study conducted by the provincial Agriculture Department that measured stray voltage on 700 farms showed that 70% of the problem was Hydro-Quebec equipment. Farmers are prepared to solve the remaining 30% themselves.

  18. High voltage testing for the MAJORANA Demonstrator

    CERN Document Server

    Abgrall, N; Avignone, F T; Barabash, A S; Bertrand, F E; Bradley, A W; Brudanin, V; Busch, M; Buuck, M; Byram, D; Caldwell, A S; Chan, Y-D; Christofferson, C D; Chu, P -H; Cuesta, C; Detwiler, J A; Doe, P J; Dunagan, C; Efremenko, Yu; Ejiri, H; Elliott, S R; Fu, Z; Galindo-Uribarri, A; Giovanetti, G K; Goett, J; Green, M P; Gruszko, J; Guinn, I S; Guiseppe, V E; Henning, R; Hoppe, E W; Howard, S; Howe, M A; Jasinski, B R; Keeter, K J; Kidd, M F; Konovalov, S I; Kouzes, R T; LaFerriere, B D; Leon, J; Li, A; MacMullin, J; Martin, R D; Massarczyk, R; Meijer, S J; Mertens, S; Orrell, J L; O'Shaughnessy, C; Poon, A W P; Radford, D C; Rager, J; Rielage, K; Robertson, R G H; Romero-Romero, E; Shanks, B; Shirchenko, M; Snyder, N; Suriano, A M; Tedeschi, D; Thompson, A; Ton, K T; Trimble, J E; Varner, R L; Vasilyev, S; Vetter, K; Vorren, K; White, B R; Wilkerson, J F; Wiseman, C; Xu, W; Yakushev, E; Yu, C -H; Yumatov, V

    2016-01-01

    The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This eff?ect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including diff?erent improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge eff?ects during the MAJORANA Demonstrator commissioning phase were studied. A stable c...

  19. Modeling of long High Voltage AC Underground

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Bak, Claus Leth; Wiechowski, W. T.

    2010-01-01

    This paper presents the work and findings of a PhD project focused on accurate high frequency modelling of long High Voltage AC Underground cables. The project is cooperation between Aalborg University and Energinet.dk. The objective of the project is to investigate the accuracy of most up to date...

  20. Ultra-low Voltage CMOS Cascode Amplifier

    DEFF Research Database (Denmark)

    Lehmann, Torsten; Cassia, Marco

    2000-01-01

    In this paper, we design a folded cascode operational transconductance amplifier in a standard CMOS process, which has a measured 69 dB DC gain, a 2 MHz bandwidth and compatible input- and output voltage levels at a 1 V power supply. This is done by a novel Current Driven Bulk (CDB) technique...